05000387/FIN-2013003-02 | Susquehanna | Talen Energy | 2013Q2 | Unacceptable Preconditioning of RPS and EOC-RPT Time Response Test | Green | IP 71111.15, Operability Determinations and Functionality Assessments | |
05000387/FIN-2013005-03 | Susquehanna | Talen Energy | 2013Q4 | Missed Technical Specification Surveillance for Secondary Containment Drawdown Testing | Green | IP 71111.22 | Missed surveillance |
05000387/FIN-2015002-03 | Susquehanna | Talen Energy | 2015Q2 | Incorrect Implementation of the Ventilation Filter Testing Program | Green | IP 71124.06, Radioactive Gaseous and Liquid Effluent Treatment | |
05000395/FIN-2017007-02 | Summer | South Carolina Electric & Gas Company | 2017Q4 | Failure to Establish a Testing Program for Inverter XIT5904 and Time Delay Relay in the EFW/SW Crosstie Valve Actuation Circuitry | Green | IP 71111.21 | |
05000400/FIN-2014007-01 | Harris | Duke Energy | 2014Q3 | Failure to Establish Test That Verified Interlock Capability | Green | IP 71111.21 | |
05000400/FIN-2015007-01 | Harris | Duke Energy | 2015Q4 | Failure to Establish As-found Testing on 6.9kV Vacuum Breakers | Green | IP 71111.17 | |
05000416/FIN-2018002-08 | Grand Gulf | Entergy | 2018Q2 | Performance of Surveillance Testing Following Maintenance on Containment Airlock | Green | IP 71153, Event Followup | |
05000423/FIN-2014002-01 | Millstone | Dominion | 2014Q1 | Failure to Evaluate Test Results Outside of Acceptance Criteria For A Service Water Pump | Green | IP 71111.15, Operability Determinations and Functionality Assessments | Significance Determination Process |
05000423/FIN-2018010-05 | Millstone | Dominion | 2018Q2 | Inadequate Test Control of ECCS Valve Interlocks | Green | IP 71111.21M, Design Bases Assurance Inspection | |
05000440/FIN-2014005-01 | Perry | FirstEnergy | 2014Q4 | Unevaluated Preconditioning of Emergency Service Water Motor-Operated Valves and Check Valves Prior to Conducting As-Found Inservice Surveillance Testing | Green | IP 71111.22 | |
05000445/FIN-2013007-07 | Comanche Peak | Luminant | 2013Q2 | Failure to Provide Appropriate Acceptance Criteria and Testing Procedure Instructions | Green | IP 71111.21 | Significance Determination Process |
05000445/FIN-2013007-08 | Comanche Peak | Luminant | 2013Q2 | Failure to Provide Appropriate Acceptance Criteria for the Safety Chill Water Pumps | Green | IP 71111.21 | Significance Determination Process |
05000445/FIN-2014004-02 | Comanche Peak | Luminant | 2014Q3 | Inadequate Acceptance Criteria for Inservice Testing of Auxiliary Feedwater Discharge Check Valves | Green | IP 71111.22 | |
05000445/FIN-2016004-01 | Comanche Peak | Luminant | 2016Q4 | Failure to Evaluate Inservice Testing Results of Power Operated Relief Valve | Green | IP 71111.04 | Stroke time Significance Determination Process |
05000445/FIN-2018001-02 | Comanche Peak | Luminant | 2018Q1 | Failure to Incorporate Design Information Into System Test Procedures | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000445/FIN-2018002-03 | Comanche Peak | Luminant | 2018Q2 | Failure to Incorporate Design Information Into System Test Procedures | Green | IP 71152, Problem Identification and Resolution (PI&R) | |
05000454/FIN-2013005-01 | Byron | Constellation | 2013Q4 | Essential Service Water Blowdown Isolation Valves Not Tested | Green | IP 71111.07, Heat Sink Performance | |
05000454/FIN-2013007-03 | Byron | Constellation | 2013Q3 | Acceptance Criteria for Battery Voltage in TS Surveillance Procedure Failed to Account for Test Equipment Uncertainty | Green | IP 71152, Problem Identification and Resolution (PI&R) | Significance Determination Process |
05000454/FIN-2018010-02 | Byron | Constellation | 2018Q1 | Failure to Periodically Test Instrument Air Check Valves Associated with Air-Operated Containment Isolation Valves | Green | IP 71111.21M, Design Bases Assurance Inspection | |
05000455/FIN-2013005-06 | Byron | Constellation | 2013Q4 | Corrosion Effects on the Unit 2 Reactor Vessel Not Monitored | Green | IP 71111.18 | Boric Acid |
05000456/FIN-2016008-01 | Braidwood | Constellation | 2016Q1 | Failure to Verify the Tripping Characteristic of Molded Case Circuit Breakers (MCCBs) Used as Isolation Devices for the 120 Vac Instrument Power System | Green | IP 71111.21 | |
05000458/FIN-2014007-01 | River Bend | Entergy | 2014Q3 | Improper Sequencing of Maintenance of 4160 Vac Circuit Breakers Prior to As-Found Tests | Green | IP 71111.21 | Significance Determination Process |
05000461/FIN-2015002-02 | Clinton | Constellation | 2015Q2 | Post-Maintenance Test Failed To Demonstrate Required Flow Through RCIC Room Cooler | Green | IP 71111.19 | Significance Determination Process |
05000482/FIN-2013008-12 | Wolf Creek | Wolf Creek Nuclear Operating Corporation | 2013Q3 | Failure to Translate Design Basis Performance Requirements into Pump Surveillance Tests | Green | IP 71111.21 | |
05000482/FIN-2014007-03 | Wolf Creek | Wolf Creek Nuclear Operating Corporation | 2014Q3 | Failure to Include the Containment Coolers in a Test Program | Green | IP 71152, Problem Identification and Resolution (PI&R) | Significance Determination Process |
05000483/FIN-2014007-04 | Callaway | Ameren | 2014Q2 | Failure to Establish Essential Service Water Pump House Supply Fan Testing. | Green | IP 71111.21 | Significance Determination Process |
05000483/FIN-2014007-07 | Callaway | Ameren | 2014Q2 | Failure to Adequately Account for Motor Operated Valve Unseating Torque in Torque Calculation. | Green | IP 71111.21 | Significance Determination Process |
05000483/FIN-2015009-03 | Callaway | Ameren | 2015Q4 | Failure to Have an Adequate Post-Maintenance Test for Setting the Motor-Driven Auxiliary Feedwater Flow Control Valve Modutronics Potentiometer | Green | IP 93812 | Significance Determination Process |
05000498/FIN-2013007-02 | South Texas | STP Nuclear Operating Company | 2014Q1 | Improper Sequencing of Maintenance of 4160 VAC Circuit Breakers Prior to As-Found Tests | Green | IP 71111.21 | Significance Determination Process |
05000498/FIN-2016007-01 | South Texas | STP Nuclear Operating Company | 2016Q1 | Failure to Perform Adequate Periodic Testing of Molded Case Circuit Breakers | Green | IP 71111.21M, Design Bases Assurance Inspection | Significance Determination Process |
05000528/FIN-2013009-02 | Palo Verde | Arizona Public Service | 2014Q1 | Deficiencies in Emergency Diesel Generator Engine Room and Control Room Ventilation Air Flow Testing and Evaluation | Green | IP 71111.21 | Significance Determination Process |