05000395/FIN-2017007-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Establish a Testing Program for Inverter XIT5904 and Time Delay Relay in the EFW/SW Crosstie Valve Actuation Circuitry |
| Description | The NRC identified an NCV of 10 CFR Part 50, Appendix B, Criterion XI, Test Control, involving two examples. Specifically, the licensee (1) failed to establish a testing program to assure the adequacy of the shutdown setpoint of the safety-related inverters, and (2) failed to establish a testing program to assure the adequacy of the time delay relay in the emergency feedwater/service water (EFW/SW) crosstie valve actuation circuitry. The licensee entered this issue into their CAP as CRs17-05534 and 17-05536, and performed an operability determination to verify that the safety-related components remained operable. The performance deficiency was determined to be more than minor because it was associated with the design control attribute of the mitigating systems cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, failing to establish a testing program for the low voltage DC setpoint of inverter XIT 5904 and for the time delay relay in the EFW/SW crosstie actuation circuitry could result in undetected degradation of the equipment to perform their intended safety functions. The team determined the finding to be of very low safety significance (Green) because it was a deficiency affecting the design or qualification of a mitigating SSC, and the SSC maintained its operability. The team determined that no cross-cutting aspect was applicable because the finding did not reflect current licensee performance. |
| Site: | Summer |
|---|---|
| Report | IR 05000395/2017007 Section 1R21 |
| Date counted | Dec 31, 2017 (2017Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | M Riley C Franklin N Morgan D Terry-Ward W Sherbin A Della Grecas Walker |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion XI |
| INPO aspect | |
| ' | |