ML20084A51115 August 1975AO 75-13:on 750815,approx 12,000 Gallons of Refueling Water Storage Tank Water Ran Into Sump B Causing Containment Basement Floor to Be Flooded & Sump a to Flood.Caused by Personnel Error
ML20084A72525 July 1975AO 75-12:on 750725,during Monthly Surveillance Procedure PT-9,undervoltage & Underfrequency Protection,Primary Undervoltage Device 273/11B Armature Did Not Drop Down to Assume de-energized Position.Caused by Scale Accumulation
ML20084A81111 April 1975AO 75-09:on 750410,control Rod Cap K-7 Inspected Due to Leak Indication & Pinhole Leak Discovered.Cap to Be Replaced
ML20084A8309 April 1975AP 75-08:on 750326,post-accident Charcoal Filter Sys a & B Tested for Filter Efficiency.Filter Bank a Tested Efficiency at 99.4% for Molecular Iodine Removal
ML20084A85124 March 1975AO 75-07:eddy Current Testing Program Indicated That 10 a & 12 B Steam Generator Hot Leg Tubes Had Wall Thinning of 50% or Greater.Cause Not Stated
ML20084A87926 February 1975AO 50-244/75-5:on 750218,safety Injection Pump 1C Failed to Start Manually from Bus 16.Cause Not Stated.Safety Injection Pump 1C Will Be Started Weekly Until 1975 Refueling Shutdown Scheduled for 750315
ML20084A88818 February 1975AO 75-05:on 750218,safety Injection Pump 1C Failed to Start from Bus 16 When Manually Activated.Cause Not Stated.Pump Will Be Started Once/Wk from Bus 16 Until PORC Changes Testing Frequency
ML20084A90321 February 1975AO 50-244/75-04:on 750213,during Performance of PT-20,MSIV Solenoid Trip Test,One Air Supply Solenoid Valve Failed to Operate When Tested.Caused by Flat Spot or Burr on Latching Pin.Linkage Adjusted
ML20084A91413 February 1975AO 75-04:on 750213,during Performance of PT-20 MSIV Solenoid Trip Test,One Air Supply Solenoid Valve on MSIV 1H Failed to Operate When Tested.Cause Not Stated.Linkage Adjusted.Test to Be Repeated Before 750315 Outage
ML20084A92514 February 1975AOs 50-244/75-02 & 50-244/75-03:on 750205 & 06,safety Injection Pump 1C Failed to Start Manually from Bus 16. Caused by Spring Being Slightly Depressed.Westinghouse to Be Notified
ML20084A9415 February 1975AO 75-02:while Conducting PT-2.1 & Following Satisfactory Test of Safety Injection Pumps 1A & B,Safety Injection Pump 1C Failed to Start Manually on Bus 16.Pumps Started from Bus 14.Thorough Insp of Breaker Recommended
ML20084A9526 February 1975AO 75-03:while Conducting Retest of Safety Injection Pump 1C on Bus 16,pump Failed to Start Manually First Time.Holding Coil of Lockout Relay & Breaker to Have Thorough Insp
ML20084B00917 January 1975AO 50-244/75-1:on 750108,turbine Governor Valve & Associated Trip & Throttle Valve Tripped to Closed Position Approx 15 After Steam Supply Quick Start Valves Opened.Caused by Degraded Lube Oil Supply Pressure Due to Instrument Drift
ML20084B0219 January 1975AO 75-1:on 750108,steam Driven Auxiliary Feedwater Pump Tripped Out After Running for Approx 15 S.Low Lube Oil Pressure Trip Setpoint Adjusted
ML20084E08420 December 1974AO 50-244/74-21:on 741211,boric Acid Tank Level Channel LC 171 Dropped to Zero Level Indication.Caused by Failure of LC 171 Power Supply Module.Module ReplacedBoric Acid
ML20084E08911 December 1974AO 50-244/74-21:on 741211,boric Acid Tank Level Transmitter LT-171 Dropped to Zero Level Indication.Cause Not StatedBoric Acid
ML20084E09618 December 1974AO 50-244/74-20:on 741209,deficiency Found in Monthly Surveillance Test Procedure PT-16 Re Auxiliary Feedwater Flow.Caused by Incorrect Ref Pressure Value.Test Procedure PT-16 Revised Based on New Data from Flow Balance
ML20084E09910 December 1974AO 50-244/74-20:on 741209,deficiency Discovered in PT-16 Flow Check Procedure of Auxiliary Feedwater Pump.Procedure Revised
ML20084E10313 December 1974AO 50-244/74-19:on 741204,during Surveillance Test PT-9, Undervoltage Relay 274/11B Failed to Operate.Caused by Scale Accumulation on Armature Plunger Opposite Upper Guide Bearing.Plunger Polished
ML20084E1115 December 1974AO 50-244/74-19:on 741204,during Monthly Surveillance Test PT-9,undervoltage Relay 274/11B Failed.Caused by Scale Accumulation on Armature Plunger Opposite Upper Guide Bearing.Plunger Polished
ML20084E12012 November 1974AO 50-244/74-18:on 741111,excessive Leakage Rate Indicated from Containment Side Purge Exhaust Valve.Caused by Crimp in Rubber Valve Seat.Crimp Smoothed Out
ML20084E1294 October 1974AO 50-244/74-17:on 740925,discrepancies Found in Level Alarm Setpoints on Accumulations.Caused by Erroneous Calculations Supplied by Westinghouse.Tech Spec Change Request Filed
ML20084E13426 September 1974AO 50-244/74-17:on 740925,possible Discrepancy Found in Vol of Borated Water in Accumulators.Cause Under Investigation. Correct Vol to Be Established When Final Accurate Figures Available
ML20084E13830 September 1974AO 50-244/74-16:on 740918,results of Water Sample Analysis Showed Boron Concentration in a Accumulator Below Tech Spec Limit.Caused by Leakage of Primary Coolant Into B Loop Accumulator.Closer Surveillance of Accumulator Maintained
ML20084E14219 September 1974AO 50-244/74-16:on 740918,results of Water Sample Analysis Showed Boron Concentration in a Accumulator Below Tech Spec Limit.Recommendations Made for Closer Surveillance of Boron Concentration in Accumulators
ML20084E14523 August 1974AO 50-244/74-15:on 740815,steam Generator a Blowdown Isolation Valve Was Only Closing 80%.Caused by Piece of Carbon Steel Resting on Top of Valve Seat Ring.Valve Stem & Plug Assembly Replaced
ML20084E14916 August 1974AO 50-244/74-15:on 740815,1A Steam Generator Blowdown Isolation Valve Failed to Close Properly.Further Insp of Valve Operator Recommended
ML20084E15215 August 1974AO 50-244/74-14:on 740807,safety Injection Pump 1C Failed to Start Manually on Bus 16.Cause Not Determined.Westinghouse Specialist to Examine Breaker.Possible Replacement of Lockout & Tripper Bar Assembly Recommended
ML20084E1587 August 1974AO 50-244/74-14:on 740807,safety Injection Pump 1C Failed to Start Manually on Bus 16.Thorough Insp Recommended
ML20084E16616 July 1974AO 50-244/74-13:on 740702,leak Discovered in Socket Weld of 3/4-inch Vent Pipe to Weldolet on Charging Pump Discharge Filter Bypass Line.Caused by Improper Weldolet Surface Preparation.New Valve & Nipple Installation RecommendedSafe Shutdown
ML20084E1693 July 1974AO 50-244/74-13:on 740702,leak Found in Weld Connecting 3/4-inch Vent Valve Nipple to Weldolet on Charging Pump Filter Bypass Line.Repairs During Cold Shutdown Recommended
ML20084E17416 July 1974AO 50-244/74-12:on 740629,leak Discovered in Socket Weld of 3/4-inch Vent Pipe to Vent Valve on Charging Pump Discharge Filter Bypass Line.Caused by Corrosion Mechanism.New Valve Installation Recommended
ML20084E1802 July 1974AO 50-244/74-12:on 740629,leak Found in Weld Connecting 3/4-inch Vent Valve to Nipple on Charging Pump Discharge Filter.Valve Replaced
ML20084E1868 July 1974AO 50-244/74-11:on 740626,main Steam Line Isolation Valve a Failed to Close.Caused by Excessive Heat to Coils & Plungers.Plungers Adjusted
ML20084E19226 June 1974AO 50-244/74-11:on 740626,main Steam Line Isolation Valve a Failed to Close.Valves Adjusted
ML20084E19521 June 1974AO 50-244/74-10:on 740613,valve 991,outlet from Primary Sys Flow Indicator FI-903 to Channel Drain Tank Reported Open. Caused by Improperly Verified Valve Alignment.Valve 991 Locked Closed
ML20084E19914 June 1974AO 50-244/74-10:on 740613,valve 991 of Sample Sys Flow Indicator FI-903 Found Open & Chemical Tank Overflowing. Valve Closed & Tank Pumped Down to Normal Level
ML20084E20610 June 1974AO 50-244/74-09:on 740530,during Surveillance Test, Underfrequency Relay 811/11A Found Inoperable.Cause Undetermined.Testing Frequency of Relays Increased
ML20084E20830 May 1974AO 50-244/74-09:on 740530,during Surveillance Test PT-9, One Underfrequency Relay on Bus 11A Failed to Transmit Signal of Simulated Fault Condition.Relay Replaced
ML20084E21421 May 1974AO 50-244/74-08:on 740511,increase in Gas Radiation Level of Auxiliary Bldg Exhaust at Vent Noticed.Caused by Dripping in General Location of a Mixed Bed Demineralizer Outlet Piping.Leak Isolated
ML20084E22014 May 1974AO 50-244/74-08:on 740511,liquid Leak in Outlet Piping from a Mixed Bed Demineralizer in Auxiliary Bldg Released Gases to Bldg Atmosphere.Leak Isolated
ML20084E2313 May 1974AO 50-244/74-07:on 740426,during Surveillance Test, Underfrequency Relay 811/11A Found Inoperable.Caused by Opening of Electrolytic Capacitor.Printed Circuit Board Replaced
ML20084E23926 April 1974AO 50-244/74-07:on 740426,during Surveillance Test PT-9,one Underfrequency Relay on 11A Bus Failed to Transmit Signal to Logic Racks When Fault Condition Simulated.Relay Replaced
ML20084E2432 May 1974AO 50-244/74-06: on 740422,RHR Pump Suction Valve 851B Failed to Open.Caused by Valve Being Too Tightly Sealed in Closed Position.Operating Procedures for Heatup Changed
ML20084E25023 April 1974AO 50-244/74-06:on 740422,RHR Valve 851B Failed to Open. Valve Manually Opened.Procedure Review Recommended
ML20084E27322 February 1974AO 50-244/74-03:on 740214,containment Purge & Exhaust Dampers Failed to Maintain Leakage Rates within Specified Levels.Caused by Paint & Dirt Debris on Disc Edges of Purge Valves.Edges Cleaned
ML20084E28115 February 1974AO 50-244/74-03:on 740214,containment Purge & Exhaust Dampers Failed to Maintain Leakage Rates within Specified Levels.Repairs to Dampers Will Be Completed
ML20084E29319 February 1974Ao:On 740101,abnormal Degradation Discovered in Steam Generator a Tubes Designed to Contain Radioactive Matls Resulting from Fission Process.Cause Undetermined.Tube Sheets Cleaned Using High Pressure Water Lance Method
ML20084E2977 February 1974AO 50-244/74-02:on 740101,eddy Current Test Results Indicated Wastage Problem Localized in Steam Generator a Hot Leg in Ctr Area of Tube Sheet.After Results of Tests Analyzed,Tube Plugging Will Be Initiated
ML20084E30928 January 1974AO 50-244/74-01:on 740118,during Removal of Insert from Steam Generator a Hot Leg Section,Inrush of Air to Generator Occurred Causing Unbalance of Pressure on Water Still in TubesShutdown Margin