ML20084B021

From kanterella
Jump to navigation Jump to search
AO 75-1:on 750108,steam Driven Auxiliary Feedwater Pump Tripped Out After Running for Approx 15 S.Low Lube Oil Pressure Trip Setpoint Adjusted
ML20084B021
Person / Time
Site: Ginna Constellation icon.png
Issue date: 01/09/1975
From: Platt C
ROCHESTER GAS & ELECTRIC CORP.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20084B012 List:
References
AO-75-1, NUDOCS 8304060074
Download: ML20084B021 (1)


Text

F

, --a ,'  ;

i <

[

.y ., . . ., , ; y O w . . . . . ~

l 7

.ff

~

3,y

b _ w; ,:.;w a a -

ROCHESTER GAS AND ELECTRIC CORPORATION e 89 EAST AVENUE, RGCHESTER, N.Y.1$las)

y tn x4,

,,i D tru e o c

, ans a conc na 546-2700

[J g, {/ ',q Ginna Station t

/ January 9, 1975 Mr. James P. O'Reilly, Director 1 -

/g , -8 -

Directorate of Regulatory Operations h-  ;

  • Q,

~

j i

Region I '

4'-L] ' I' k O ,

U.S.A.E.C. .s j 631 Park Avenue / g@_G

'C 9 Kir.g of prussia, Pa. 19406 . . -

2

Subject:

Abnormal Occurrence #75-1 Failure of the Steam Driven Auxiliary Feedwater Pump to respond properly during surveillance test, Docket No. 50-244

Dear Mr. O'Reilly:

This is to confirm my phone call to Mr. Walter Baunack today to report ,

Abnormal Occurrence # hat Ginna Station. "

Whilc, conduc ting the montbly PT-16, (Auxiliary Feedwater Flow) surveillance i tes t on Jc.n.:ary 0, 1975, the s teu dr iven auxiliary feedwater_ pump _ tripped ou_t af ter running f or apprcximately 15 seconds. The pump uns started tuo I

more tines, and each tire it again tripped out af ter 15 seconds. The low lube oil pressure trip setpoint was adjusted and then the pump was started I l again. This time the pump remained in operation and the PT-16 surveillance test was completed with no further problems.

.s Very truly yours ,

Charles E. Platt Superintendent CEP:bg cc: Mr. J. F. O ' Leary, AEC Mr. L. D. White, Jr. , RG&E Mr. G. J. Swarthout, RG&E PDR 401