Category:INSPECTION REPORT
MONTHYEARML24211A0592024-07-29029 July 2024 Framatome Inc. – Physical Security Core Inspection Report 07001257-2024401 Public ML24190A0292024-07-19019 July 2024 Framatome - Richland - Core Inspection Report 07001257/2024002 ML24116A2922024-04-29029 April 2024 Framatome-Richland - Core Inspection Report 07001257/2024001 ML24026A2792024-01-31031 January 2024 Framatome - Richland – Integrated Inspection Report 07001257/2023004 ML23296A0072023-10-25025 October 2023 Framatome-Richland - Core Inspection Report 07001257/2023003 ML23202A2022023-07-24024 July 2023 Framatome Richland Core Inspection Report 07001257/2023002 ML23089A2592023-04-10010 April 2023 2023-001 Framatome-Richland - NRC Integrated Inspection Report 07001257/2023001 ML23030B6172023-01-31031 January 2023 Framatome-Richland - Core Inspection Report 07001257/2022004 ML22291A0342022-10-17017 October 2022 Framatome Inspection Request (2022 Nuclear Criticality and Emergency Preparedness) ML22201A5352022-07-21021 July 2022 Framatome 2022-002 Integrated Quarterly Inspection Report ML22024A2152022-01-25025 January 2022 Framatome, Inc. - Richland, U.S. Nuclear Regulatory Commission Integrated Inspection Report 07001257/2021004 ML21298A2242021-10-25025 October 2021 Framatome-Richland Integrated Inspection Report 07001257/2021003 ML21237A3092021-08-25025 August 2021 Framatome - Material Control and Accounting Program Inspection Report 07001257/2021401 (OUO Removed) ML21221A1852021-08-0606 August 2021 NRC Doc Request Fram OPS-PMA IR 2021-003 ML21189A0042021-07-0707 July 2021 Framatome-Richland Integrated Inspection Report 07001257/2021002 ML21113A2292021-04-23023 April 2021 Framatome - Richland, U.S. Nuclear Regulatory Commission Inspection Report Number 70-1257/2021-001 ML21025A2902021-01-22022 January 2021 Framatome Inc. - U. S. Nuclear Regulatory Commission Integrated Inspection Report 07001257/2020004 ML20303A2512020-10-29029 October 2020 Framatome, Inc. - U.S. Nuclear Regulatory Commission Integrated Inspection Report Number 70-1257/2020-003 ML20302A4312020-10-28028 October 2020 Framatome Inc., U.S. Nuclear Regulatory Commission Inspection Report 2020-401 Public ML20184A2822020-07-0202 July 2020 Framatome Inc., - NRC Integrated Inspection Report 701257/2020001 and 701257/2020-002 ML20030A2612020-01-29029 January 2020 Framatome Quarterly IR 2019-005 ML19301A0762019-10-25025 October 2019 Framatome Inc. - U. S. Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2019-004 ML19214A1162019-08-0202 August 2019 Framatome, Inc., Nuclear Regulatory Commission Integrated Inspection Report 07001257/2019003 ML19109A0022019-04-17017 April 2019 Framatome Quarterly IR 2019-002 ML19025A0172019-01-25025 January 2019 Framatome, Inc. - Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2018-005 ML18297A0902018-10-24024 October 2018 Framatome Quarterly IR 2018-004 ML18200A2402018-07-19019 July 2018 Framatome Inc., - Nuclear Regulatory Integrated Inspection Report 07001257/2018003 ML18110A0232018-04-20020 April 2018 Framatome Inc., - Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2018002 ML18025B2502018-01-25025 January 2018 Framatome Inc., - NRC Integrated Inspection Report 0701257/2017005 ML1100306952010-12-30030 December 2010 IR 70-1257-10-010 & Notice of Violation, on 11/18/10, Areva Np, Inc., Richland ML20211G7501999-08-25025 August 1999 Partially Withheld Insp Rept 70-1257/99-201 (Ref 10CFR2.790) on 990802-05.No Violations Noted.Major Areas Inspected:Exams of Core Procedures & Representative Records & Interviews with Personnel.Details Withheld ML20211B9261999-08-19019 August 1999 Insp Rept 70-1257/99-202 on 990802-05.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Safety Training,Administrative Controls,Internal Audits & Internal Reporting of Nuclear Criticality Safety Infractions ML20210R9071999-08-12012 August 1999 Insp Rept 70-1257/99-02 on 990712-16.No Violations Noted. Major Areas Inspected:Selected Aspects of Licensee Programs for Operational Safety,Radioactive Effluents,Environ Protection,Waste Mgt Programs & Followup of Open Items ML20207B3781999-05-21021 May 1999 Insp Rept 70-1257/99-01 on 990322-26,0514 & 21.Violations Noted.Major Areas Inspected;Licensee Programs for Radiation Protection,Emergency Preparedness,Operator Training, Transportation & Followup of Open Items from Previous Insps ML20198F6021998-12-15015 December 1998 Insp Rept 70-1257/98-05 on 981026-30.No Violations Noted. Major Areas Inspected:Operations,Operational Event Review Feedback & Mgt Organization ML20198B4361998-12-14014 December 1998 Insp Rept 70-1257/98-204 on 981109-13.Violation Noted. Major Areas Inspected:Open Item Completion,Review of Recent Licensee Criticality Safety Event,Validation & Criticality Safety Analysis ML20151X0721998-09-16016 September 1998 Insp Rept 70-1257/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Operational Safety,Maint & Surveillance,Transportation & follow-up of Open Items from Previous Insps ML20236R2841998-07-17017 July 1998 Insp Rept 70-1257/98-03 on 980615-19.Violations Noted.Major Areas Inspected:Selected Aspects of Operational Safety, Radiation Protection,Radioactive Waste Handling & Storage ML20248K0011998-06-0202 June 1998 Insp Rept 70-1257/98-02 on 980413-17 & 980504-08.No Violations Noted.Major Areas Inspected:Operational Safety, Radioactive Effluents & Environ Protection ML20217J8671998-04-0101 April 1998 Insp Rept 70-1257/98-201 on 980313-19.Violations Noted.Major Areas Inspected:Open Item Resolution,Configuration Mgt & Flowdown of Analytical Limits & Controls ML20203K3731998-02-24024 February 1998 Insp Rept 70-1257/98-01 on 980126-30.No Violations Noted. Major Areas Inspected:Review of Mgt Organization & Controls, Operational Event Review & Feedback,Operator Training & Qualification & Selected Aspects of Operational Safety ML20198S5181998-01-16016 January 1998 Insp Rept 70-1257/97-07 on 971215-19 & 971222-24.Violations Noted.Major Areas Inspected:Ep,Operations & Followup on Open Items from Previous Insps ML20199B9431997-11-0707 November 1997 Insp Rept 70-1257/97-202 on 971006-10.Violation Noted.Major Areas Inspected:Criticality Safety Analyses,Chemical Safety Assessment,Chemical & Criticality Safety Controls,Active Engineering Controls & Administrative Controls Flowdown ML20217G9641997-10-0808 October 1997 Insp Rept 70-1257/97-06 on 970915-19.No Violations Noted. Major Areas Inspected:Selected Aspects of Operations & Radiation Protection ML20198H4171997-09-0505 September 1997 Insp Rept 70-1257/97-201 on 970804-08.No Violations Noted. Info Re Major Areas Inspected Withheld,Per 10CFR2.790(d) ML20046D7991997-09-0505 September 1997 Non-proprietary Cover Sheet to Insp Rept 70-1257/97-201 on 970804-08.Details of Rept Withheld,Per 10CFR2.790(d) ML20141K5791997-05-23023 May 1997 Insp Rept 70-1257/97-04 on 970414-18,23,24 & 0501.Violations Noted.Major Areas Inspected:Operations,Radioactive Effluent Discharges,Environ Protection,Solid Radioactive Waste Mgt & Transportation of Radioactive Matls ML20137P1301997-04-0404 April 1997 Insp Rept 70-1257/97-03 on 970303-07.No Violations Noted. Major Areas Inspected:Aspects of Plant Operations, Engineering,Maint & Surveillance Testing ML20136C1611997-03-0707 March 1997 Insp Rept 70-1257/97-02 on 970210-12.No Violation Noted. Major Areas Inspected:Physical Security Plan,Safeguards Events,Fixed Site Physical Protection of Special Nuclear Matl of Low Strategic Significance & Insp Folloup Item ML20134C7331997-01-30030 January 1997 Insp Rept 70-1257/97-01 on 970106-10.Violation Noted.Major Areas Inspected:Mgt Organization & Controls,Operator Training & Qualification,Plant Operations & Engineering 2024-07-29
[Table view] Category:NRC-GENERATED
MONTHYEARML20211G7501999-08-25025 August 1999 Partially Withheld Insp Rept 70-1257/99-201 (Ref 10CFR2.790) on 990802-05.No Violations Noted.Major Areas Inspected:Exams of Core Procedures & Representative Records & Interviews with Personnel.Details Withheld ML20211B9261999-08-19019 August 1999 Insp Rept 70-1257/99-202 on 990802-05.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Safety Training,Administrative Controls,Internal Audits & Internal Reporting of Nuclear Criticality Safety Infractions ML20210R9071999-08-12012 August 1999 Insp Rept 70-1257/99-02 on 990712-16.No Violations Noted. Major Areas Inspected:Selected Aspects of Licensee Programs for Operational Safety,Radioactive Effluents,Environ Protection,Waste Mgt Programs & Followup of Open Items ML20207B3781999-05-21021 May 1999 Insp Rept 70-1257/99-01 on 990322-26,0514 & 21.Violations Noted.Major Areas Inspected;Licensee Programs for Radiation Protection,Emergency Preparedness,Operator Training, Transportation & Followup of Open Items from Previous Insps ML20198F6021998-12-15015 December 1998 Insp Rept 70-1257/98-05 on 981026-30.No Violations Noted. Major Areas Inspected:Operations,Operational Event Review Feedback & Mgt Organization ML20198B4361998-12-14014 December 1998 Insp Rept 70-1257/98-204 on 981109-13.Violation Noted. Major Areas Inspected:Open Item Completion,Review of Recent Licensee Criticality Safety Event,Validation & Criticality Safety Analysis ML20151X0721998-09-16016 September 1998 Insp Rept 70-1257/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Operational Safety,Maint & Surveillance,Transportation & follow-up of Open Items from Previous Insps ML20236R2841998-07-17017 July 1998 Insp Rept 70-1257/98-03 on 980615-19.Violations Noted.Major Areas Inspected:Selected Aspects of Operational Safety, Radiation Protection,Radioactive Waste Handling & Storage ML20248K0011998-06-0202 June 1998 Insp Rept 70-1257/98-02 on 980413-17 & 980504-08.No Violations Noted.Major Areas Inspected:Operational Safety, Radioactive Effluents & Environ Protection ML20217J8671998-04-0101 April 1998 Insp Rept 70-1257/98-201 on 980313-19.Violations Noted.Major Areas Inspected:Open Item Resolution,Configuration Mgt & Flowdown of Analytical Limits & Controls ML20203K3731998-02-24024 February 1998 Insp Rept 70-1257/98-01 on 980126-30.No Violations Noted. Major Areas Inspected:Review of Mgt Organization & Controls, Operational Event Review & Feedback,Operator Training & Qualification & Selected Aspects of Operational Safety ML20198S5181998-01-16016 January 1998 Insp Rept 70-1257/97-07 on 971215-19 & 971222-24.Violations Noted.Major Areas Inspected:Ep,Operations & Followup on Open Items from Previous Insps ML20199B9431997-11-0707 November 1997 Insp Rept 70-1257/97-202 on 971006-10.Violation Noted.Major Areas Inspected:Criticality Safety Analyses,Chemical Safety Assessment,Chemical & Criticality Safety Controls,Active Engineering Controls & Administrative Controls Flowdown ML20217G9641997-10-0808 October 1997 Insp Rept 70-1257/97-06 on 970915-19.No Violations Noted. Major Areas Inspected:Selected Aspects of Operations & Radiation Protection ML20198H4171997-09-0505 September 1997 Insp Rept 70-1257/97-201 on 970804-08.No Violations Noted. Info Re Major Areas Inspected Withheld,Per 10CFR2.790(d) ML20046D7991997-09-0505 September 1997 Non-proprietary Cover Sheet to Insp Rept 70-1257/97-201 on 970804-08.Details of Rept Withheld,Per 10CFR2.790(d) ML20141K5791997-05-23023 May 1997 Insp Rept 70-1257/97-04 on 970414-18,23,24 & 0501.Violations Noted.Major Areas Inspected:Operations,Radioactive Effluent Discharges,Environ Protection,Solid Radioactive Waste Mgt & Transportation of Radioactive Matls ML20137P1301997-04-0404 April 1997 Insp Rept 70-1257/97-03 on 970303-07.No Violations Noted. Major Areas Inspected:Aspects of Plant Operations, Engineering,Maint & Surveillance Testing ML20136C1611997-03-0707 March 1997 Insp Rept 70-1257/97-02 on 970210-12.No Violation Noted. Major Areas Inspected:Physical Security Plan,Safeguards Events,Fixed Site Physical Protection of Special Nuclear Matl of Low Strategic Significance & Insp Folloup Item ML20134C7331997-01-30030 January 1997 Insp Rept 70-1257/97-01 on 970106-10.Violation Noted.Major Areas Inspected:Mgt Organization & Controls,Operator Training & Qualification,Plant Operations & Engineering ML20133D0291997-01-0303 January 1997 Insp Rept 70-1257/96-206 on 961202-05.Violations Noted. Major Areas Inspected:Fuel Fabrication Facility in Richland,Wa,Activities Associated W/Planned Startup of New Dry Conversion Facility & Review of Hq Insp Procedure 88015 ML20135D8221996-12-0505 December 1996 Insp Rept 70-1257/96-205 on 961104-07.No Violations Noted. Details Withheld ML20134K8161996-11-12012 November 1996 Insp Rept 70-1257/96-04 on 961021-25.Violations Noted.Major Areas Inspected:Emergency Preparedness,Fp,Followup on Licensee Events & Followup on Open Item from Previous Item ML20149H4771994-11-0202 November 1994 Insp Rept 70-1257/94-06 on 940926-30 & 1012-14.Violations Noted.Major Areas Inspected:Review Circumstances Re 940918 Event,Involving Spill of Approx 41 Kg of Low Enriched U Dioxide Power ML20058H9321993-11-22022 November 1993 Insp Rept 70-1257/93-12 on 931101-05.No Violations Noted. Major Areas Inspected:Fire Protection & Followup on Items of Noncompliance,Inspector Followup Items & NRC Info Notices ML20058D4261993-10-17017 October 1993 Insp Rept 70-1257/93-11 on 930908 & 0927-1001.No Violations or Deviations Noted.Major Areas Inspected:Criticality Safety,Operations & Followup on Open Items ML20057C5041993-08-26026 August 1993 Insp Rept 70-1257/93-10 on 930812.No Violations Noted.Major Areas Inspected:Announced Insp to Obtain Info on Licensee Employee Concerns Program ML20046D3401993-08-12012 August 1993 Partially Withheld Insp Rept 70-1257/93-201 on 930712-16. Details Withheld (Ref 10CFR2.790.) ML20056E4111993-08-0808 August 1993 Insp Rept 70-1257/93-09 on 930726-30.Violations Noted But Not Cited.Major Areas Inspected:Maint/Surveillance Testing, Radiation Protection,Criticality Safety/Operations Review, Environ/Waste Mgt & Followup on Open Items ML20056E9041993-08-0404 August 1993 Insp Rept 70-1257/93-08 on 930628-0702.No Violations Noted. Major Areas Inspected:Review Licensee Emergency Preparedness Program & Followup on Open Items ML20056C8711993-07-0707 July 1993 Insp Rept 70-1257/93-07 on 930614-18.No Violations Noted. Major Areas Inspected:Environ Protection,Radwaste Mgt, Onsite Followup of Licensee Events & Followup on Open Items ML20045C6081993-06-0707 June 1993 Insp Rept 70-1257/93-03 on 930412-16.Violations Noted.Major Areas Inspected:Mgt/Organization,Training/Qualification, Transportation of Radioactive Matls & Waste Generator Requirements ML20045C2041993-06-0101 June 1993 Enforcement Conference Rept 70-1257/93-06 on 930517.Major Areas Discussed:Apparent Violations Identified During AIT Insp (NRC Insp Rept 70-1257/93-02) & in-ofc Review of AIT Findings (NRC Insp Rept 70-1257/93-05),dtd 930430 ML20044G1211993-05-19019 May 1993 Insp Rept 70-1257/93-04 on 930226-0409.Violations Noted. Major Areas Inspected:Control Room Operations,Licensee Action on Previous Insp Findings,Criticality Safety Controls Radiological Controls & Special Insp Topics ML20035A0861993-03-10010 March 1993 Insp Rept 70-1257/93-02 on 930209-12.Enforcement Issues Not Addressed.Major Areas Inspected:Circumstances & Cause of 930207 Event Re Inadvertent Accumulation of 124 Kg Low Enriched U Oxide Powder Inside Lexan Encl ML20035B7281993-03-0909 March 1993 Insp Rept 70-1257/93-01 on 930204-11.Violations Noted.Major Areas Inspected:Radiation Protection Program Including Procedures,Instrument & Equipment & Contamination Surveys ML20127B1621992-12-23023 December 1992 Insp Rept 70-1257/92-09 on 921207-11.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection & Followup on Items of Noncompliance,Inspector Followup Items & NRC Info Notices ML20126B3451992-12-0404 December 1992 Insp Rept 70-1257/92-08 on 921015-17 & 29.Violations Noted. Major Areas Inspected:Overflow of Low Enriched Uranyl Fluoride to U Hexafluoride Vaporization Chest ML20024H2481991-05-23023 May 1991 Partially Withheld Physical Security Insp Rept 70-1257/91-02 on 910422-0508 (Ref 10CFR2.790(d)).No Violations or Deviations Noted.Major Areas Inspected:Plans,Procedures & Reviews,Safeguards Event Repts & Protection of SNM ML20059H9681990-09-0505 September 1990 Partially Withheld Insp Rept 70-1257/90-201 on 900806-10 (Ref 10CFR2.790(d)).No Violations,Deviations or Declining Performance Identified.Major Areas Inspected:Physical Inventory & Measurement Control ML20059G8981990-08-31031 August 1990 Insp Rept 70-1257/90-03 on 900813-17.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection, Maint & Surveillance Testing,Transportation of Radioactive Matls & Criticality Safety ML20012B8131990-03-0202 March 1990 Insp Rept 70-1257/90-01 900108-12 & 0205-09.Violations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Mgt & Organization,Operator Training/Retraining, Criticality Safety & Operations Review ML19324C3071989-11-0808 November 1989 Insp Rept 70-1257/89-03 on 890925-29.Violations Noted.Major Areas Inspected:Criticality Safety,Operations Review,Maint & Surveillance Testing,Radwaste Mgt,Environ Protection, Emergency Preparedness & Radwaste Generator Requirements ML20245H0751989-08-0909 August 1989 Matl Control & Accounting Insp Rept 70-1257/89-201 on 890612-21.No Violations,Deviations or Declining Performance Identified.Major Areas Inspected:Measurement Sys,Physical Inventory & Records & Repts ML20247H6391989-05-22022 May 1989 Insp Rept 70-1257/89-02 on 890417-21.No Violations Noted. Major Areas Inspected:Followup Actions on Open Items,Mgt Organization,Training & Retraining,Criticality Safety, Operations Review & Radiation Protection ML20247P5161989-04-0505 April 1989 Insp Rept 70-1257/89-200 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys,Measurement Controls & Matl Control & Accounting for Exports & Imports ML20195F9841988-11-18018 November 1988 Insp Rept 70-1257/88-08 on 880906-09 & 23.Violations Noted. Major Areas Inspected:Mgt Organization,Training & Retraining,Criticality Safety,Operations Review,Maint & Surveillance Testing ML20154J6151988-05-12012 May 1988 Insp Rept 70-1257/88-04 on 880418-22.No Violations Noted. Major Areas Inspected:Mgt Organization,Criticality Safety, Operations Review,Maint & Surveillance Testing & Radwaste Mgt ML20236C9151987-10-20020 October 1987 Insp Rept 70-1257/87-08 on 870928-1002.No Violations Noted. Major Areas Inspected:Mgt Organization & Controls, Criticality Safety,Operations Review,Training,Radiation Protection & Emergency Preparedness & Environ Protection ML20235X1551987-07-20020 July 1987 Insp Rept 70-1257/87-05 on 870606-12 & 0701.No Violations Noted.Major Areas Inspected:Mgt Organization & Controls, Criticality Safety,Operations Review,Transportation/Radwaste Mgt & Emergency Preparedness & Environ Protection 1999-08-25
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARML20211G7501999-08-25025 August 1999 Partially Withheld Insp Rept 70-1257/99-201 (Ref 10CFR2.790) on 990802-05.No Violations Noted.Major Areas Inspected:Exams of Core Procedures & Representative Records & Interviews with Personnel.Details Withheld ML20211B9261999-08-19019 August 1999 Insp Rept 70-1257/99-202 on 990802-05.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Safety Training,Administrative Controls,Internal Audits & Internal Reporting of Nuclear Criticality Safety Infractions PNO-IV-99-036, on 990813,licensee Notified NRC Operations Ctr That Inaccurate Lab Analysis Method Resulted in Potential for Criticality Safety Limit to Be Exceeded by 23%.Affected Process Was Shut Down & Tagged Out.Region Will Conduct Insp1999-08-18018 August 1999 PNO-IV-99-036:on 990813,licensee Notified NRC Operations Ctr That Inaccurate Lab Analysis Method Resulted in Potential for Criticality Safety Limit to Be Exceeded by 23%.Affected Process Was Shut Down & Tagged Out.Region Will Conduct Insp ML20210R9071999-08-12012 August 1999 Insp Rept 70-1257/99-02 on 990712-16.No Violations Noted. Major Areas Inspected:Selected Aspects of Licensee Programs for Operational Safety,Radioactive Effluents,Environ Protection,Waste Mgt Programs & Followup of Open Items ML20207B3781999-05-21021 May 1999 Insp Rept 70-1257/99-01 on 990322-26,0514 & 21.Violations Noted.Major Areas Inspected;Licensee Programs for Radiation Protection,Emergency Preparedness,Operator Training, Transportation & Followup of Open Items from Previous Insps ML20207B3731999-05-21021 May 1999 Notice of Violation from Insp on 990322-26,0514 & 21. Violations Noted:On 980225,licensee Delivered Licensed Matl to Carrier for Transport Under General License Pursuant to 10CFR71.12 & Did Not Comply with Terms & Conditions PNO-III-99-005, on 990202,truck with Empty UF6 Cylinders Involved in Traffic Accident.Local Fire & Police Personnel Responded Immediately to Scene of Accident.Driver of tractor-trailer Received Minor Injuries1999-02-0303 February 1999 PNO-III-99-005:on 990202,truck with Empty UF6 Cylinders Involved in Traffic Accident.Local Fire & Police Personnel Responded Immediately to Scene of Accident.Driver of tractor-trailer Received Minor Injuries ML20198F6021998-12-15015 December 1998 Insp Rept 70-1257/98-05 on 981026-30.No Violations Noted. Major Areas Inspected:Operations,Operational Event Review Feedback & Mgt Organization ML20198B4361998-12-14014 December 1998 Insp Rept 70-1257/98-204 on 981109-13.Violation Noted. Major Areas Inspected:Open Item Completion,Review of Recent Licensee Criticality Safety Event,Validation & Criticality Safety Analysis ML20198B4191998-12-14014 December 1998 Notice of Violation from Insp on 981109-13.Violation Noted: Failure to Control Decommissioning Operations So That Operators Would Verify That Disassembled Equipment Was Free from Visible U Deposits Before Staging with Other Equipment PNO-IV-98-043, on 980922,NRC Operation Ctr Notified That Criticality Safety Specialist Noted Visible Accumulations of Solids in Disassembled Sections of Ductwork.Training Planned for Disassembly Crew in Aspects of Safety Requirements1998-09-23023 September 1998 PNO-IV-98-043:on 980922,NRC Operation Ctr Notified That Criticality Safety Specialist Noted Visible Accumulations of Solids in Disassembled Sections of Ductwork.Training Planned for Disassembly Crew in Aspects of Safety Requirements ML20151X0721998-09-16016 September 1998 Insp Rept 70-1257/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Operational Safety,Maint & Surveillance,Transportation & follow-up of Open Items from Previous Insps ML20236R2741998-07-17017 July 1998 Notice of Violation from Insp on 980615-19.Violation Noted: Operational Safety Activities Not Implemented Iaw/Documented Standard Operating Procedures Appropriate to Circumstances in Listed Examples ML20236R2841998-07-17017 July 1998 Insp Rept 70-1257/98-03 on 980615-19.Violations Noted.Major Areas Inspected:Selected Aspects of Operational Safety, Radiation Protection,Radioactive Waste Handling & Storage PNO-IV-98-022, on 980605,notified Nrc,Region IV That Mfg Sciences Corp Had Returned Shipment of Zirconium Cladding After Discovery of Two Unirradiated Fuel Pellets within Cladding.Nrc Region IV Will Perform follow-up Review1998-06-0505 June 1998 PNO-IV-98-022:on 980605,notified Nrc,Region IV That Mfg Sciences Corp Had Returned Shipment of Zirconium Cladding After Discovery of Two Unirradiated Fuel Pellets within Cladding.Nrc Region IV Will Perform follow-up Review ML20248K0011998-06-0202 June 1998 Insp Rept 70-1257/98-02 on 980413-17 & 980504-08.No Violations Noted.Major Areas Inspected:Operational Safety, Radioactive Effluents & Environ Protection PNO-IV-98-017A, on 980415,licensee Conducted Conducted Briefing of Region IV & Headquarters Staff on Details of Fire.Location & Matls Involved in Fire,Described in Original Preliminary Notification of Event or Unusual Occurrence1998-04-16016 April 1998 PNO-IV-98-017A:on 980415,licensee Conducted Conducted Briefing of Region IV & Headquarters Staff on Details of Fire.Location & Matls Involved in Fire,Described in Original Preliminary Notification of Event or Unusual Occurrence PNO-IV-98-017, on 980415,licensee Reported to NRC Operations Ctr That Fire Had Occurred in Handling Area of UO2 Bldg.Fire Initially Quelled w/CO2 & Then Extinguished W/Small Amount of Water.Licensee Scheduled to Conduct Briefing W/Nrc1998-04-15015 April 1998 PNO-IV-98-017:on 980415,licensee Reported to NRC Operations Ctr That Fire Had Occurred in Handling Area of UO2 Bldg.Fire Initially Quelled w/CO2 & Then Extinguished W/Small Amount of Water.Licensee Scheduled to Conduct Briefing W/Nrc ML20217J8671998-04-0101 April 1998 Insp Rept 70-1257/98-201 on 980313-19.Violations Noted.Major Areas Inspected:Open Item Resolution,Configuration Mgt & Flowdown of Analytical Limits & Controls ML20203K3731998-02-24024 February 1998 Insp Rept 70-1257/98-01 on 980126-30.No Violations Noted. Major Areas Inspected:Review of Mgt Organization & Controls, Operational Event Review & Feedback,Operator Training & Qualification & Selected Aspects of Operational Safety ML20198S4961998-01-16016 January 1998 Notice of Violation from Insp on 971215-19 & 971222-24. Violation Noted:On 971218,licensee Discovered That U Compounds Other than Oxide Pellets Were Being Stored in Temporary Storage Locations ML20198S5181998-01-16016 January 1998 Insp Rept 70-1257/97-07 on 971215-19 & 971222-24.Violations Noted.Major Areas Inspected:Ep,Operations & Followup on Open Items from Previous Insps ML20199B9431997-11-0707 November 1997 Insp Rept 70-1257/97-202 on 971006-10.Violation Noted.Major Areas Inspected:Criticality Safety Analyses,Chemical Safety Assessment,Chemical & Criticality Safety Controls,Active Engineering Controls & Administrative Controls Flowdown ML20199B9341997-11-0707 November 1997 Notice of Violation from Insp on 971006-10.Violation Noted: April 1977 Loss of Moisture Control Incident at Dry Conversion Pilot Plant Was Not Adequately Reviewed & Appropriate Corrective Actions Were Not Taken ML20217G9641997-10-0808 October 1997 Insp Rept 70-1257/97-06 on 970915-19.No Violations Noted. Major Areas Inspected:Selected Aspects of Operations & Radiation Protection PNO-IV-97-053, on 970917,Siemens Nuclear Corp Reported Discovery of Damp U Dioxide Matl in Transfer Line in Dry Conversion Pilot Facility Sample Analyses of Pyrohyrolysis Vessel.Licensee Rept Made,Per NRC Bulletin 91-0011997-09-18018 September 1997 PNO-IV-97-053:on 970917,Siemens Nuclear Corp Reported Discovery of Damp U Dioxide Matl in Transfer Line in Dry Conversion Pilot Facility Sample Analyses of Pyrohyrolysis Vessel.Licensee Rept Made,Per NRC Bulletin 91-001 ML20216J0851997-09-12012 September 1997 Notice of Violation from Insp on 970731.Violation Noted: on 970413,RL Rumley,Lead Operator,Defeated Breathing Zone Air Sampler by Placing Rubber Glove Over Air Sampler at Respective Work Station ML20046D7991997-09-0505 September 1997 Non-proprietary Cover Sheet to Insp Rept 70-1257/97-201 on 970804-08.Details of Rept Withheld,Per 10CFR2.790(d) ML20198H4171997-09-0505 September 1997 Insp Rept 70-1257/97-201 on 970804-08.No Violations Noted. Info Re Major Areas Inspected Withheld,Per 10CFR2.790(d) ML20141K5781997-05-23023 May 1997 Notice of Violation from Insp on 970414-18,23,24 & 0501. Violation Noted:On 960603,licensee Shipped 405 NT-IX Shipping Packages Containing Fissile Matl W/O Installing Cushioning Matl ML20141K5791997-05-23023 May 1997 Insp Rept 70-1257/97-04 on 970414-18,23,24 & 0501.Violations Noted.Major Areas Inspected:Operations,Radioactive Effluent Discharges,Environ Protection,Solid Radioactive Waste Mgt & Transportation of Radioactive Matls ML20137P1301997-04-0404 April 1997 Insp Rept 70-1257/97-03 on 970303-07.No Violations Noted. Major Areas Inspected:Aspects of Plant Operations, Engineering,Maint & Surveillance Testing ML20136C1611997-03-0707 March 1997 Insp Rept 70-1257/97-02 on 970210-12.No Violation Noted. Major Areas Inspected:Physical Security Plan,Safeguards Events,Fixed Site Physical Protection of Special Nuclear Matl of Low Strategic Significance & Insp Folloup Item ML20134C7331997-01-30030 January 1997 Insp Rept 70-1257/97-01 on 970106-10.Violation Noted.Major Areas Inspected:Mgt Organization & Controls,Operator Training & Qualification,Plant Operations & Engineering ML20134C7241997-01-30030 January 1997 Notice of Violation from Insp on 970106-10.Violation Noted: Field Change Made Under Open ECN (No.5533L) & Not Documented or Included W/Ecn Package Prior to Startup Approval on 960806 PNO-III-97-004, on 970124,truck Carrying Four U Hexafluoride Cylinders in Accident Occurred.Truck Transporting Cylinders from Portsmouth Gaseous Diffusion Plant to Siemens Power Corp in Richland,Washington1997-01-24024 January 1997 PNO-III-97-004:on 970124,truck Carrying Four U Hexafluoride Cylinders in Accident Occurred.Truck Transporting Cylinders from Portsmouth Gaseous Diffusion Plant to Siemens Power Corp in Richland,Washington ML20133D0231997-01-0303 January 1997 Notice of Violation from Insp on 961202-05.Violation Noted: Licensee Failed to Update Posted Criticality Safety Limit Card for UF6 Cylinder Wash Operation to Reflect Change in CCS Limit ML20133D0291997-01-0303 January 1997 Insp Rept 70-1257/96-206 on 961202-05.Violations Noted. Major Areas Inspected:Fuel Fabrication Facility in Richland,Wa,Activities Associated W/Planned Startup of New Dry Conversion Facility & Review of Hq Insp Procedure 88015 PNO-IV-96-066, on 961211,licensee Notified Nrc,Walnut Creek Field Ofc of Electrical Fire & Partial Loss of Site Power. Licensee Formed Incident Investigation Board to Review Event.State of Wa Will Be Informed1996-12-12012 December 1996 PNO-IV-96-066:on 961211,licensee Notified Nrc,Walnut Creek Field Ofc of Electrical Fire & Partial Loss of Site Power. Licensee Formed Incident Investigation Board to Review Event.State of Wa Will Be Informed ML20135D8221996-12-0505 December 1996 Insp Rept 70-1257/96-205 on 961104-07.No Violations Noted. Details Withheld ML20134K8161996-11-12012 November 1996 Insp Rept 70-1257/96-04 on 961021-25.Violations Noted.Major Areas Inspected:Emergency Preparedness,Fp,Followup on Licensee Events & Followup on Open Item from Previous Item ML20134K7921996-11-12012 November 1996 Notice of Violation from Insp on 961021-25.Violation Noted: as of 961022,licensee Had Not Calibrated Three Sets of direct-reading Dosimeters Maintained for Er Since 950918,for Two Sets & Since 950725,for the Third Set ML20149H4581994-11-10010 November 1994 Notice of Violation from Insp on 940926-30 & 1012-14. Violations Noted:Licensee Did Not Provide Training to Operators Relative to Modification or Evaluate Need to Revise Operating Procedures Prior to Restarting Sys ML20149H4771994-11-0202 November 1994 Insp Rept 70-1257/94-06 on 940926-30 & 1012-14.Violations Noted.Major Areas Inspected:Review Circumstances Re 940918 Event,Involving Spill of Approx 41 Kg of Low Enriched U Dioxide Power ML20058H9321993-11-22022 November 1993 Insp Rept 70-1257/93-12 on 931101-05.No Violations Noted. Major Areas Inspected:Fire Protection & Followup on Items of Noncompliance,Inspector Followup Items & NRC Info Notices ML20058D4261993-10-17017 October 1993 Insp Rept 70-1257/93-11 on 930908 & 0927-1001.No Violations or Deviations Noted.Major Areas Inspected:Criticality Safety,Operations & Followup on Open Items ML20057C5041993-08-26026 August 1993 Insp Rept 70-1257/93-10 on 930812.No Violations Noted.Major Areas Inspected:Announced Insp to Obtain Info on Licensee Employee Concerns Program ML20046D3401993-08-12012 August 1993 Partially Withheld Insp Rept 70-1257/93-201 on 930712-16. Details Withheld (Ref 10CFR2.790.) ML20056E4111993-08-0808 August 1993 Insp Rept 70-1257/93-09 on 930726-30.Violations Noted But Not Cited.Major Areas Inspected:Maint/Surveillance Testing, Radiation Protection,Criticality Safety/Operations Review, Environ/Waste Mgt & Followup on Open Items ML20056E9041993-08-0404 August 1993 Insp Rept 70-1257/93-08 on 930628-0702.No Violations Noted. Major Areas Inspected:Review Licensee Emergency Preparedness Program & Followup on Open Items 1999-08-25
[Table view] |
Text
.
ENCLOSURE 2 U.S. NUCLEAR REGULATORY COMMISSION REGION IV Docket Nos.: 70 1257 i License No.: SNM-1227 1
Certificate of Compliance Nos.: 6581,9248 EA No.: 99-085 Report No.: 70-1257/99-01 Licensee: Siemens Power Corporation (SPC)
Facility: Siemens Power Corporation Location: Richland, Washington Dates: March 22-26,1999, and May 14,1999, and May 21,1999 Inspector: Wayne L. Britz, Fuel Facility inspector Fuel Cycle Decommissioning Branch Division of Nuclear Materials Safety (DNMS)
Accompanied By: Linda L. Howell, Technical Assistant, DNMS Approved By: D. Blair Spitzberg, Ph.D., Chief Fuel Cycle / Decommissioning Branch, DNMS ATTACHMENT: Supplemental inspection information
)
l DO 257 .
C PDR }
l I
l 1
EXECUTIVE
SUMMARY
Siemens Power Corporation NRC Inspection Report 70-1257/99-01 This routine, announced inspection included a review of selected aspects of the licensee's programs for radiation protection, emergency preparedness, operator training, transportation, and followup of open items from previous inspections.
I Radiation Protection
. The inspector concluded through procedure review, record review and interviews with facility staff that the external dosimetry program was effectively implemented onsite consistent with 10 CFR 20.1502,20.2102, and 20.2106 (Section 1.1).
Emeraency Preparedness
. The licensee maintained a good inventory of emergency response equipment and supplies that were in a state of operational readiness. The Emergency Plan is being enhanced based on experiences following an event which tested the notification process (Section 2.1). )
Operator Trainina
. The licensee was adequately providing training to employees and tracking the training needs of the employees (Section 3.1).
Transoortation
. The loading, packaging, preparation for shipment and shipment of transportation containers observed during the March 22-26,1999, inspection was performed and l documented according to procedures (Section 4.1). l
. Required audits of the transportation program were performed. The Quality i Assurance (OA) Program is still undergoing a program upgrade in response to a prior NRC inspection. The OA Program has been submitted to NRC for review and approval.
The results of the program upgrade will be reviewed during future inspections (Section 4.2).
. . The licensee had assigned a new full-time person and two temporary assignees to work on transportation program enhancements (Section 4.2).
. A violation of 10 CFR 71.12 was identified involving the licensee's use of several Model 51032-1 shipping containers which did not conform with Certificate of Compliance No. 6581 (Section 4.3). Another example of a 10 CFR 71.12 violation was identified involving the licensee's use of several Model SP-1 shipping containers which did not conform with Certificate of Compliance No. 9248 (Section 6.2).
. A violation involving 10 CFR 71.85 was identified involving the licensee's use of several Model SP-1 shipping containers to which model numbers were applied without determining that the packaging has been fabricated in accordance with Certificate of Compliance No. 9248 (Section 6.2).
- . A violation of 10 CFR 71.133 was identified with two examples. One example involved the licensee's established measures not having assured that conditions adverse to quality were promptly identified during inspections of the Model 51032-1 shipping containers between March and June 1998 (Section 4.3). Another example of a 10 CFR 71.133 violation was identified involving the licensee's continued use of Model SP-1 inner shipping containers with identified nonconformances which were not promptly corrected (Section 6.2).
1 4
4 Report Detalls Summary of Plant Status The plant was operating Lines 1 and 2 of the dry conversion facility (DCF). Uranium recovery I activities were also in operation. Fuel pellet production, fuel rod loading and downloading, and fuel bundle assembly operations were also in progress.
1 Radiation Protection (83822) 1.1 Insoection Scope The inspector reviewed selected portions of the external dosimetry program io determine compliance with 10 CFR 20.1502,20.2102, and 20.2106 requirements for monitoring occupational workers for external radiation exposure and maintaining records I of occupational exposures, and interviewed licensee health physics staff.
1.2. Observations and Findinas The inspector discussed procedures for administering external dosimetry to personnel based on work location and potential to receive dose. Procedures specify certain groups of workers who require dosimetry based on their work location, if they work in
)
posted radiation areas 8 or more hours per week on the average or who would be expected to receive an annual deep dose in excess of 250 mrem. Exposure records for the period 1996 through 1998 were reviewed. Quarterly exposure records for various work groups were reviewed as well as the dosimetry files for selected personnel. The storage and retention process for exposure records were reviewed. Radiological exposures recorded were within the regulations for occupational workers. No concerns were identified with the procedures or records reviewed.
1.3. Conclusion The inspector concluded through procedure review, record review and interviews with facility staff that the external dosimetry program was effectively implemented consistent with 10 CFR 20.1502,20.2102, and 20.2106.
2 Emergency Preparedness (88050) 2.1 Inspection Scope The inspector toured the licensee's facilities to examine selected emergency response equipment maintained in emergency repositories, and the changes being made to stream! iris emergency notification info mation to county and state officials.
5-2.2. Observations and Findinas The inspector noted that the emergency equipment repositories contained equiprnent identified in the licensee's Emergency Plan. The cabinets containing emergency equipment were clearly identifiable, contents were orderly, and they appeared to be well maintained. The inspector noted that the placement of certain types of equipment was near the areas most likely to be needed.
The inspector noted changes were being made to the Emergency Plan as a result of experiences following the April 15,1998, fire which resulted in emergency notifications to state and county personnel. Revisions are being made to Part 1, " Emergency Plan,"
and Part 3," Implementing Procedures." A description of the Modular Extraction / Recovery Facility (MERF) being placed into service is being added to the Emergency Plan and the prioritization of the call list to the state and county is being revised. Part 2, the Quick Reference Section, and Part 4, " Memorandums of Understanding," are up to dcte.
The inspector noted that the emergency equipment repositories were consistent with tha Emergency Plan. The inspectors noted that enhancements were being made to improve the emergency notification process. No concerns were identified. {
2.3. Conclusions The licensee maintained a good inventory of well maintained emergency response 1
j equipment and supplies that were in a state of operational readiness. The Emergency j Plan is being enhanced based on experiences following an event which tested the l notification process.
3 Operator Training / Retraining (88010) 3.1 inspection Scope The inspector reviewed the licensee's general employee training (GET), radiological worker training (RWT), the training program for various plant workers, the records i system documenting training, toured the various training locations and observed !
equipment used in training.
3.2. Observations and Findinas The inspector observed the training provided to new employees, the new employee required reading list, the materials and equipment used to train new employees for their various positions, and the testing and records of the completed training.
Personnel working in designated radiological areas and in special skills positions receive more comprehensive radiological and technical training. The training includes work station training on procedures and on-the-job training with written tests and skill demonstrations. Control room operators receive extensive training on the computer controlled DCF. The inspector reviewed the depth of training, written tests administered
6-to new personnel, and skills testing provided for DCF control room operators, UO2 shop operations
- personnel, and DCF powder preparation personnel. The inspector found the training and testing adequate and had no concerns. ]
Employee refresher training is provided by completion of interactive video for several topics such as hazard communications, hearing conservation, heat / cold stress, criticality safety, annual radiological worker training, annual safety training and respiratory protection. Other refresher training is provided by classroom instruction and testing.
The inspector found the refresher training adequate and had no concerns. !
The training data base was examined for several employees. The data base contains records of all training provided to the employees over the years with the employee data, 1
the course subject / description, revision number, instructor, and the date of the course. 1 A commitment tracking system sends training due notifications to personnel. The inspector found the training data base adequate and had no concerns.
3.3 Conclusions i I
The licensee was adequately providing training to employees and tracking the training I needs of the employees.
4 Transportation of Radioactive Materials (86740) 4.1 Radioactive Materials Packaaina. Labelina. Storaae and Maintenance i 1
- a. Insoect;on Scoce !
The inspector reviewed packaging, labeling and storage of shipping containers prior to shipment, and the maintenance and rework of containers. The inspection consisted of procedural reviews, interviews and observation of work being performed to implement the requirements of 10 CFR Part 71, the license, and Certificates of Compliance,
- b. Observations and Findinas The inspector observed preparation and shipment of four fuel assemblies in SP-1 containers, including shipping paper preparation, the safety check of the truck and trailer, the radiation protection check and the overall procedural requirements.
The inspector observed the loading of powder into containers, the health and safety {
conditions, and the criticality safety controls applicable to this evolution.
l The above observations also included safety discussions and interviews with personnel.
The inspector found the loading and shipment evolutions observed to be adequate and had no concerns.
1
c-l
- c. Conclusions The loading, packaging, preparation for shipment and shipment of transportation I containers were performed and documented according to procedures. l 4.2 OA Proaram for Transportation of Shiocina Packaaes
- a. Insoection Scoce On March 17,1998, the NRC issued Confirmatory Action Letter (CAL)
No. NMSS 98-8-002 describing the licensees commitments to implement certain corrective actions related to SPC's transportation OA program. The licensee documented the status of these actions in several responses to the CAL, and the CAL was closed on December 7,1998. The inspector reviewed QA procedures and QA audit ,
reports executed after the OA program was revised in response to the NRC CAL.
- b. Observations and Findings J The inspector reviewed documents related to the QA program for transportation. The licensee's document EMF-1, Revision 30, Part II," Quality Assurance Program for Nuclear Fuels, Services, and Packaging and Transportation of Radioactive Materials,"
was submitted to the NRC for review and approval on December 23,1998. The OA program revision incorporates the existing EMF-439, " Quality Assurance Program for Nuclear Fuel Shipping Containers," Revision 11, into EMF-1 to provide a single OA program to comply with both 10 CFR Part 50, Appendix B, and 10 CFR Part 71, Subpart H. The revised QA program corrects the previous program which provided for minor changes to shipping containers, an issue which is discussed in Inspection Report 71-0003/98-203.
Work practice guides a ; heing written to provide additional guidance to the SPC staff.
Work Practice Manual EMF-2084, Revision 0," Licensing of Shipping Containers," was reviewed. The manual describes the responsibilities of various departments involved in the certification of shipping containers, determining the need for an application, the i' application process, and the container certificate review and maintenance.
The inspector reviewed SPC Internal Audit Summary Report (Audit 98:45), " Shipping !
Containers (EMF-439)," dated March 1,1999. The audit was performed to evaluate the effectiveness of licensee actions taken in response to issues raised during a February 1998 inspection (NRC Inspection Report 71-0003/98-203). The inspector reviewed two audits performed by Regulatory Compliance as required by Chapter 5 of EMF-30, Safety Manual," Radioactive Material Shipment Audit," dated November 16,1998; and
" EMF-30 Chapter 5 Radioactive Materials Shipping Audit," dated January 14,1999.
Two self-assessments performed by OA personnel for compliance with 10 CFR Part 71 were also reviewed.
The inspector reviewed audits performed by the licensee's consultant who has performed prior assessments at SPC and a root cause analysis in response to the CAL.
1 l
8-l The auditor conducted an exit briefing the week prior to the current NRC inspection. l The inspector found the audits adequate and had no concerns. j The inspector reviewed organizational changes made to support the licensee's i trancportation program. A new position in Regulatory Compliance was established and 1 a person was hired to devote full time to shipping containers. Two other staff mernbers were temporarily assigned to work on transportation program improvements.
The inspector found the personnel provided to support the transportation program were adequate. No concerns were identified.
l
- c. Conclusions Required audits of the transportation program had been performed. The OA program is !
still undergoing a program upgrade in response to a prior NRC inspection. The QA i program has been submitted for review and approval to the NRC. The results of the l program upgrade will be reviewed during future inspections.
The licensee had assigned a new full time person and two temporary assignees to work on transportation program enhancements.
4.3 Review of Shiocina Container Condition Reco_r1
- a. Insoection Scoce The inspector reviewed Condition Report No. 7477, "51032 Shipping Containers - Weld inspection," dated March 18,1999, and subsequent 30-day report submitted to the NRC on April 16,1999.
- b. Observations and Findinas The inspector reviewed the licensee identified nonconformance documented in Condition Report No. 7477 dated March 18,1999, concerning five Model 51032-1 shipping containers that were determined to have multiple welds located on the strongback and outer container shellihat did not conform to drawings referenced in the applicable Certificate of Compliance. The licensee's immediate remedial action was to reinspect the same welds on all 71 previously inspected and released 51032-1 shipping containers to determine if they conformed to the drawings referenced in the Certificate of Compliance. The licensee determined that most of the remaining containers were in nonconformance, and the containers were removed from service until they could be brought into compliance with the license drawings. The licensee submitted a " Report of Non-Compliance with Conditions of Fissile Material Shipping Container Certificate of Compliance, Siemens Power Corporation; Docket No. 71-6581," on April 16,1999,as required by 10 CFR 71.95.
All of the 51032-1 containers had been previously inspected between March and June 1998 (except the five described above) as part of the compensatory actions taken in response to the NRC's February 1998 inspection of the transportation program. The licensee is evaluating the reasons that its inspection program did not identify these
s 9
nonconformances on the containers when they were previously inspected for nonconformances during the March to June 1998 time period.
10 CFR 71.12 conditionally grants a general license to any licensee of the Commission l to transport, or to deliver to a carrier for transport, licensed material in a package for which a Certificate of Compliance was issued, and requires that the licensee comply with the terms and conditions of the certificate. Certificate of Compliance No. 6581 has l been issued for the Model 51032-1 shipping container and describes conditions for its '
use. The licensee's use of the Model 51032-1 containers which did not conform to drawings referenced in Certificate of Compliance No. 6581 was identified as the second example of a violation of 10 CFR 71.12 (71-9248/9901-01). In addition,10 CFR 71.133 states, in part, that the licensee shall establish measures to assure that conditions adverse to quality such as nonconformances are promptly identified and corrected. The l failure to promptly identify multiple weld nonconformances on Model 51032-1 shipping containers when they were inspected by the licensee between March and June 1998 was identified as the second example of a violation of 10 CFR 71.133 (71-9248/9901-03).
- c. Conclusions l
The licensee's use of shipping container Model 51032-1 in nonconformance with its Certificate of Compliance No. 6581 was identified as a violation of 10 CFR 71.12 and 10 CFR 71.133.
5 Year 2000 Readiness Status SPC does have a program in place to evaluate Year 2000 (Y2K) readiness. The company has adopted a procedure similar to one developed for use by nuclear power l pants to evaluate Y2K readiness. The procedure, EMF-2097, SPC Year 2000 l Readiness, was reviewed and was determined to be comprehensive. The procedure provides for assessment of information technology readiness as well as potential hardware issues, and requires that risk assessments be used as part of the readiness review process in order to prioritize system testing and projected replacement of systems or components which are not either Y2K compliant or compatible. The procedure calls for date testing for potentially significant dates such as 9/9/99,01/01/00, and the next leap year. SPC has assigned a Y2K project team to review assessments ,
completed by various departments, and the project team consists of representatives I from all business units. Two project team representatives were interviewed during the inspection regarding SPC's findings and progress in assessing Y2K readiness.
SPC has identified several information management systems and process controls which are not Y2K compliant. The issues involving these systems are described below.
Information Technoloav (IT):
Siemens has an extensive database for maintaining training records for personnel. This system has recently been identified as Y2K non-compliant. The central file server must
3 l 9 l
1 be replaced because it is date sensitive. The system will be upgraded in the June 1999 time frame.
I The SPC laboratory (onsite lab) analysis systems are known to be date sensitive and cannot be relied upon to generate automated reports after December 31,1999. SPC is evaluating use of another software program to assign dates rather than relying only l l upon the current software. l l l l
The nuclear materials accountability system is being replaced. The system relies upon l l a mainframe which may be 9/9/99 sensitive (based on reports which have appeared in l IT trade journals). SPC is trying to replace this mainframe prior to September 1999, and will definitely replace the system before the year 2000.
I Hardware and Process Control:
The distributed control systems (DCS) for both the ammonium diuranate (ADU) process line and the new DCF are not Y2K compliant. The ADU line in the uranium 1
dioxide (UO2) area is an older system which runs controllers for the process. Although the DCS is not Y2K compliant, the controllers are not equipped with clocks, thus they are not date sensitive. Replacement of the DCS for the ADU line is planned for later this calendar year. The DCS for the DCF facility is also not Y2K compliant. SPC is evaluating changes for this control system.
There are a number of process monitors and various types of recorders which are stand alone systems. These systems are being tested for Y2K compliance; results of the ;
licensee's evaluation are not yet available.
SPC plans to complete the high priority initial date sensitive testing by the end of June !
- so that they can include the results of the evaluation in SPC's response to NRC Generic Letter 98-03.
SPC does plan to be in production on December 31,1999, due to a heavy production and shipping schedule. IT personnel will be on site on December 31 to provide support should any problems be identified. SPC managers believe that they have "no system l that couldn't be manually shut down or safely controlled." With regard to potential disruption of power, critical process control systems and ventilation systems are '
equipped with a backup emergency power supply (diesel generator).
6 Followup (92701 and 92702) 6.1 (Closed) Unresolved item (URI) 70-1257/9805-01: Failure to remove uranium during dismantlement of ductwork as required by criticality safety requirements. Inspection '
l Report 98-204 dated December 14,1998, documented NRC's review of URI 70-1257/9805-01 and was issued in conjunction with a Notice of Violation. The violation involved disassembling ductwork without verifying that the ductwork was free from visible uranium as required by the criticality safety specification. The licensee
! responded to the Notice of Violation by letter dated January 12,1999, and provided
! descriptions of corrective actions taken and additional corrective actions to be taken.
l l
l J
T The inspectors reviewed the corrective actions completed and those in progress. The inspector reviewed the changes made to the ADU Line 2 ductwork to improve the geometry and ductwork inspection capability and reviewed the revision in progress to EMF-858," Maintenance Work Permit," to address the pre-job briefings. This URI is closed, but followup inspections will be performed to verify completion of the corrective actions for the identified violation.
6.2 (Closed) URI 71-0003/98-203 01: SPC's use of an SP-1 package that did not conform with the applicable Certificate of Compliance. Inspection Report No. 71-0003/98-203 dated June 2,1998, described circumstances associated with URI 71-0003/98203-01.
The resolution of these items is complete and three v.olations of NRC requirements were identified. The portions of the URI details support;ng the three violations issued in this inspection report are summarized below.
The inspection team found that SPC shipped a fresh fuel shipment using a nonconforming SP-1 package on February 25,1998. Condition 5(a)(3) " Drawings" of COC No. 9248, requires that the packaging be fabricated in accordance with SPC Drawing No. EMF-304,416, Revision 5. However, the inspectors found that an SP-1 inner container purchased from Lanzen was not fabricated in accordance with the drawing. The drawing specifies weld configurations for lugs used to close the SP-1 inner container. The inspectors found that the required weld configurations did not exist on an SP-1 inner container fabricated by Lanzen and accepted by SPC. In addition, on February 26,1998, SPC Traffic and Warehousing informed the inspection team that they made a quick check of the packages and found that all SP-1 inner containers built by Lanzen appeared to be in the nonconforming condition.10 CFR 71.12 states, in part, that a general license to transport licensed material, or to deliver licensed material to a carrier for transport. applies only to a licensee who complies with the terms and conditions of the certificate. The shipment of a package not in accordance with its j Certificate of Compliance was identified as the first example of a violation of j 10 CFR 71.12 (71-9248/9901-01).
The inspection team found that SPC allowed identification information for Model SP-1 packagings to be applied by the fabricator, Lanzen, even though the packagings were not in compliance with the design approved by NRC in Certificate of Compliance No. 9248. The application of the model number before the first use of any packaging for the shipment of licensed material without determining that the packaging has been fabricated in accordance with the design approved by the Commission is a violation of 10 CFR 71.85 (71-9248/9901-02).
The inspection team found that SPC Variance Report No. 5540, dated November 7, 1994, identified corrective actions for nonconformances identified with SP 1 inner containers purchased from .Lanzen. SPC issued General Nonconformance Report No. 6077, dated April 7,1997, to address the failure to complete the proposed corrective l actions not completed since issuance of Variance Report No. 5540. The corrective actions were not made by the time of the NRC inspection in February 1998. The continued use of the containers with identified nonconformances which are not promptly corrected was identified as the first example of a violation of 10 CFR 71.133 (71-9248/9901-03).
E 1 l
t i
l l
7 Exit Meeting Summary The inspector presented the inspection results to members of licensee management at ,
l the conclusion of the inspection on March 26,1999. The facility staff acknowledged the '
findings presented. The licensee did not identify any of the information discussed at the meeting as proprietary. Telephone re-exits were held on May 14,1999, and May 21, 1999, to present the violations developed as a result the investigation of an unresolved item and the licensee identified violation concerning continuing problems with shipping container nonconformances.
1 1
1 l
1 i
l l
l l
l l
l l
J
r 3
ATTACHMENT l l
SUPPLEMENTAL INSPECTION INFORMATION PARTIAL LIST OF PERSONS CONTACTED Licensee B. F. Bentley, Manager, Plant Operations D. L. Beit, Radiological Safety Training J. K. Davis, Supervisor, Receiving & Component inspection J. B. Edgar, Regulatory Compliance B. N. Femreite, Vice President, Manufacturing ;
E. L. Foster, Supervisor, Radiological Safety l S. F. Gaines, Manager, Materials & Scheduling R. L. Gentz, Traffic & Logistics L. E. Hansen, Manager, Manufacturing Engineering J. L. Holm, Senior Quality Engineer ;
E. J. Hough, Technical Training Specialist l B. E. Lewis, Project Engineer, Plant Engineering L. J. Maas, Manager, Regulatory Compliance C. D. Manning, Criticality Safety M. R. O'Neill, Manager, Maintenance Engineering L. C. Phillips, Traffic & Logistics T. C. Probasco, Manager, Safety W. E. Tadlock, Chemical Operations Training A. L. Trost, Quality Engineering R. S. Utter, Manager, Corporate Information Services l
INSPECTION PROCEDURES USED j i
83822 Radiation Protection 88050 Emergency Preparedness 88010 Operator Training / Retraining 86740 Transportation 92701 Followup IFis 92702 Followup Violations ITEMS OPENED, CLOSED, AND DISCUSSED Opened 71-9248/9901-01 VIO Failure to comply with 10 CFR 71.12 requirements for the terms and conditions of the certificate of compliance (Example 1 is closed; Example 2 remains open) 71-9248/9901-02 VIO Failure to comply with 10 CFR 71.85 requirements that packaging has been fabricated in accordance with the design approved before the model number is applied to the package
e 3 71-9248/9901-03 VIO Failure to comply with 10 CFR 71.133 requirements to assure nonconformances are promptly identified and corrected (Example 1 is closed; Example 2 remains open)
Closed 71-0003/98203-01 URI SPC's use of an SP-1 package that did not conform with its COC 70-1257/9805-01 URI Review failure to remove uranium during dismantlement of ductwolk as required by criticality safety requirements 71-9248/9901-02 VIO Failure to comply with 10 CFR 71.85 requirements that packaging has been fabricated in accordance with the design approved before the model number is applied to the package LIST OF ACRONYMS USED ADU ammonium diuranate CAL confirmatory action letter DCF dry conversion facility DCS distributed control system GET general employee training IT information technology MERF modular extraction / recovery facility NRC Nuclear Regulatory Commission i
PDR public document room OA quality assurance RWT radiological worker training SPC Siemens Power Corporation UO, uranium dioxide URI unresolved item VIO violation Y2K year 2000 i
i
. j