ML21237A309
| ML21237A309 | |
| Person / Time | |
|---|---|
| Site: | Framatome ANP Richland |
| Issue date: | 08/25/2021 |
| From: | Eric Michel NRC/RGN-II |
| To: | Stephens L Framatome |
| References | |
| IR 2021401 | |
| Download: ML21237A309 (3) | |
Text
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION Enclosure(s) transmitted herewith contain(s) SUNSI. When separated from enclosure(s), this transmittal document is decontrolled.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION August 25, 2021 Mr. Lance Stephens Richland Site Manager Framatome, Inc.
2101 Horn Rapids Road Richland, WA 99354-0130
SUBJECT:
FRAMATOME - MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT 07001257/2021401
Dear Mr. Stephens:
On July 29, 2021, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Framatome and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.
No violations of more than minor significance were identified during this inspection.
This letter will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
The enclosed report contains Security-Related Information, so the enclosed report will not be made publicly available in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390(d)(1). If you choose to provide a response that contains Security-Related Information, please mark your entire response Security-Related Information-Withhold from public disclosure under 10 CFR 2.390 in accordance with 10 CFR 2.390(d)(1) and follow the
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION L. Stephens 2
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION instructions for withholding in 10 CFR 2.390(b)(1). The NRC is waiving the affidavit requirements for your response in accordance with 10 CFR 2.390(b)(1)(ii).
Sincerely,
/RA/
Eric C. Michel, Chief Projects Branch 2 Division of Fuel Facility Inspection Docket No. 07001257 License No. SNM-1227
Enclosure:
As stated cc w/o encl: Distribution via LISTSERV
ML21237A309 (Cover letter)
Entire Report:
x SUNSI Review Non-Sensitive x Sensitive Publicly Available x Non-Publicly Available Cover Letter Only:
SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available OFFICE RII/DFFI RII/DRP RII/DFFI NAME M. Romano M. Toth E. Michel DATE 8/20/21 8/23/21 8/23/2021