S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFEGUARDS Report No.:
70-1257/93-201 i
License No.:
SNM-1227 Safeguards Group:
III Licensee:
Siemens Power Corporation 2101 Horn Rapids Road Richland, WA 99352-0130 Inspection Conducted:
July 12-16, 1993 n
Inspectors:
? -
b!i'/'7%
C. SI Light /[$C&A Physical Scientist Da'te sig5'ed Inspection Section l
Operations Branch kh AWJA 7 lS $
/
F. Cassano, /2C&A Physical Scientist Date Signed j
Inspection Section t
Operations Branch Approved by:
J/ 'Ydrdunfa, ' Acting Section Leader Date Signed
~
n I,nspection Section p "ations Branch
SUMMARY
I The areas examined during this routine naterial' control and Scope:
accounting (MC&A) safeguards inspection included physical inventory, internal controls, measurement systems, measurement control, and previously identified inspector follow-up items (IFI).
Results:
Within the scope of this inspection, no violations were identified.
Five new follow-up items were opened (see ) and one previous. follow-up item was closed while l
four remain open.
ENCLOSURE 1 93081800e3 930813 m
.hDR ADOCK 07001257 hj PDR ps
?