Category:INSPECTION REPORT
MONTHYEARML24211A0592024-07-29029 July 2024 Framatome Inc. – Physical Security Core Inspection Report 07001257-2024401 Public ML24190A0292024-07-19019 July 2024 Framatome - Richland - Core Inspection Report 07001257/2024002 ML24116A2922024-04-29029 April 2024 Framatome-Richland - Core Inspection Report 07001257/2024001 ML24026A2792024-01-31031 January 2024 Framatome - Richland – Integrated Inspection Report 07001257/2023004 ML23296A0072023-10-25025 October 2023 Framatome-Richland - Core Inspection Report 07001257/2023003 ML23202A2022023-07-24024 July 2023 Framatome Richland Core Inspection Report 07001257/2023002 ML23089A2592023-04-10010 April 2023 2023-001 Framatome-Richland - NRC Integrated Inspection Report 07001257/2023001 ML23030B6172023-01-31031 January 2023 Framatome-Richland - Core Inspection Report 07001257/2022004 ML22291A0342022-10-17017 October 2022 Framatome Inspection Request (2022 Nuclear Criticality and Emergency Preparedness) ML22201A5352022-07-21021 July 2022 Framatome 2022-002 Integrated Quarterly Inspection Report ML22024A2152022-01-25025 January 2022 Framatome, Inc. - Richland, U.S. Nuclear Regulatory Commission Integrated Inspection Report 07001257/2021004 ML21298A2242021-10-25025 October 2021 Framatome-Richland Integrated Inspection Report 07001257/2021003 ML21237A3092021-08-25025 August 2021 Framatome - Material Control and Accounting Program Inspection Report 07001257/2021401 (OUO Removed) ML21221A1852021-08-0606 August 2021 NRC Doc Request Fram OPS-PMA IR 2021-003 ML21189A0042021-07-0707 July 2021 Framatome-Richland Integrated Inspection Report 07001257/2021002 ML21113A2292021-04-23023 April 2021 Framatome - Richland, U.S. Nuclear Regulatory Commission Inspection Report Number 70-1257/2021-001 ML21025A2902021-01-22022 January 2021 Framatome Inc. - U. S. Nuclear Regulatory Commission Integrated Inspection Report 07001257/2020004 ML20303A2512020-10-29029 October 2020 Framatome, Inc. - U.S. Nuclear Regulatory Commission Integrated Inspection Report Number 70-1257/2020-003 ML20302A4312020-10-28028 October 2020 Framatome Inc., U.S. Nuclear Regulatory Commission Inspection Report 2020-401 Public ML20184A2822020-07-0202 July 2020 Framatome Inc., - NRC Integrated Inspection Report 701257/2020001 and 701257/2020-002 ML20030A2612020-01-29029 January 2020 Framatome Quarterly IR 2019-005 ML19301A0762019-10-25025 October 2019 Framatome Inc. - U. S. Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2019-004 ML19214A1162019-08-0202 August 2019 Framatome, Inc., Nuclear Regulatory Commission Integrated Inspection Report 07001257/2019003 ML19109A0022019-04-17017 April 2019 Framatome Quarterly IR 2019-002 ML19025A0172019-01-25025 January 2019 Framatome, Inc. - Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2018-005 ML18297A0902018-10-24024 October 2018 Framatome Quarterly IR 2018-004 ML18200A2402018-07-19019 July 2018 Framatome Inc., - Nuclear Regulatory Integrated Inspection Report 07001257/2018003 ML18110A0232018-04-20020 April 2018 Framatome Inc., - Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2018002 ML18025B2502018-01-25025 January 2018 Framatome Inc., - NRC Integrated Inspection Report 0701257/2017005 ML1100306952010-12-30030 December 2010 IR 70-1257-10-010 & Notice of Violation, on 11/18/10, Areva Np, Inc., Richland ML20211G7501999-08-25025 August 1999 Partially Withheld Insp Rept 70-1257/99-201 (Ref 10CFR2.790) on 990802-05.No Violations Noted.Major Areas Inspected:Exams of Core Procedures & Representative Records & Interviews with Personnel.Details Withheld ML20211B9261999-08-19019 August 1999 Insp Rept 70-1257/99-202 on 990802-05.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Safety Training,Administrative Controls,Internal Audits & Internal Reporting of Nuclear Criticality Safety Infractions ML20210R9071999-08-12012 August 1999 Insp Rept 70-1257/99-02 on 990712-16.No Violations Noted. Major Areas Inspected:Selected Aspects of Licensee Programs for Operational Safety,Radioactive Effluents,Environ Protection,Waste Mgt Programs & Followup of Open Items ML20207B3781999-05-21021 May 1999 Insp Rept 70-1257/99-01 on 990322-26,0514 & 21.Violations Noted.Major Areas Inspected;Licensee Programs for Radiation Protection,Emergency Preparedness,Operator Training, Transportation & Followup of Open Items from Previous Insps ML20198F6021998-12-15015 December 1998 Insp Rept 70-1257/98-05 on 981026-30.No Violations Noted. Major Areas Inspected:Operations,Operational Event Review Feedback & Mgt Organization ML20198B4361998-12-14014 December 1998 Insp Rept 70-1257/98-204 on 981109-13.Violation Noted. Major Areas Inspected:Open Item Completion,Review of Recent Licensee Criticality Safety Event,Validation & Criticality Safety Analysis ML20151X0721998-09-16016 September 1998 Insp Rept 70-1257/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Operational Safety,Maint & Surveillance,Transportation & follow-up of Open Items from Previous Insps ML20236R2841998-07-17017 July 1998 Insp Rept 70-1257/98-03 on 980615-19.Violations Noted.Major Areas Inspected:Selected Aspects of Operational Safety, Radiation Protection,Radioactive Waste Handling & Storage ML20248K0011998-06-0202 June 1998 Insp Rept 70-1257/98-02 on 980413-17 & 980504-08.No Violations Noted.Major Areas Inspected:Operational Safety, Radioactive Effluents & Environ Protection ML20217J8671998-04-0101 April 1998 Insp Rept 70-1257/98-201 on 980313-19.Violations Noted.Major Areas Inspected:Open Item Resolution,Configuration Mgt & Flowdown of Analytical Limits & Controls ML20203K3731998-02-24024 February 1998 Insp Rept 70-1257/98-01 on 980126-30.No Violations Noted. Major Areas Inspected:Review of Mgt Organization & Controls, Operational Event Review & Feedback,Operator Training & Qualification & Selected Aspects of Operational Safety ML20198S5181998-01-16016 January 1998 Insp Rept 70-1257/97-07 on 971215-19 & 971222-24.Violations Noted.Major Areas Inspected:Ep,Operations & Followup on Open Items from Previous Insps ML20199B9431997-11-0707 November 1997 Insp Rept 70-1257/97-202 on 971006-10.Violation Noted.Major Areas Inspected:Criticality Safety Analyses,Chemical Safety Assessment,Chemical & Criticality Safety Controls,Active Engineering Controls & Administrative Controls Flowdown ML20217G9641997-10-0808 October 1997 Insp Rept 70-1257/97-06 on 970915-19.No Violations Noted. Major Areas Inspected:Selected Aspects of Operations & Radiation Protection ML20198H4171997-09-0505 September 1997 Insp Rept 70-1257/97-201 on 970804-08.No Violations Noted. Info Re Major Areas Inspected Withheld,Per 10CFR2.790(d) ML20046D7991997-09-0505 September 1997 Non-proprietary Cover Sheet to Insp Rept 70-1257/97-201 on 970804-08.Details of Rept Withheld,Per 10CFR2.790(d) ML20141K5791997-05-23023 May 1997 Insp Rept 70-1257/97-04 on 970414-18,23,24 & 0501.Violations Noted.Major Areas Inspected:Operations,Radioactive Effluent Discharges,Environ Protection,Solid Radioactive Waste Mgt & Transportation of Radioactive Matls ML20137P1301997-04-0404 April 1997 Insp Rept 70-1257/97-03 on 970303-07.No Violations Noted. Major Areas Inspected:Aspects of Plant Operations, Engineering,Maint & Surveillance Testing ML20136C1611997-03-0707 March 1997 Insp Rept 70-1257/97-02 on 970210-12.No Violation Noted. Major Areas Inspected:Physical Security Plan,Safeguards Events,Fixed Site Physical Protection of Special Nuclear Matl of Low Strategic Significance & Insp Folloup Item ML20134C7331997-01-30030 January 1997 Insp Rept 70-1257/97-01 on 970106-10.Violation Noted.Major Areas Inspected:Mgt Organization & Controls,Operator Training & Qualification,Plant Operations & Engineering 2024-07-29
[Table view] Category:MANUFACTURER/VENDOR/ENGINEER
MONTHYEARML20059H9681990-09-0505 September 1990 Partially Withheld Insp Rept 70-1257/90-201 on 900806-10 (Ref 10CFR2.790(d)).No Violations,Deviations or Declining Performance Identified.Major Areas Inspected:Physical Inventory & Measurement Control ML20059G8981990-08-31031 August 1990 Insp Rept 70-1257/90-03 on 900813-17.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection, Maint & Surveillance Testing,Transportation of Radioactive Matls & Criticality Safety ML20012B8131990-03-0202 March 1990 Insp Rept 70-1257/90-01 900108-12 & 0205-09.Violations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Mgt & Organization,Operator Training/Retraining, Criticality Safety & Operations Review ML19324C3071989-11-0808 November 1989 Insp Rept 70-1257/89-03 on 890925-29.Violations Noted.Major Areas Inspected:Criticality Safety,Operations Review,Maint & Surveillance Testing,Radwaste Mgt,Environ Protection, Emergency Preparedness & Radwaste Generator Requirements ML20245H0751989-08-0909 August 1989 Matl Control & Accounting Insp Rept 70-1257/89-201 on 890612-21.No Violations,Deviations or Declining Performance Identified.Major Areas Inspected:Measurement Sys,Physical Inventory & Records & Repts ML20247H6391989-05-22022 May 1989 Insp Rept 70-1257/89-02 on 890417-21.No Violations Noted. Major Areas Inspected:Followup Actions on Open Items,Mgt Organization,Training & Retraining,Criticality Safety, Operations Review & Radiation Protection ML20247P5161989-04-0505 April 1989 Insp Rept 70-1257/89-200 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys,Measurement Controls & Matl Control & Accounting for Exports & Imports ML20195F9841988-11-18018 November 1988 Insp Rept 70-1257/88-08 on 880906-09 & 23.Violations Noted. Major Areas Inspected:Mgt Organization,Training & Retraining,Criticality Safety,Operations Review,Maint & Surveillance Testing ML20154J6151988-05-12012 May 1988 Insp Rept 70-1257/88-04 on 880418-22.No Violations Noted. Major Areas Inspected:Mgt Organization,Criticality Safety, Operations Review,Maint & Surveillance Testing & Radwaste Mgt ML20235X1551987-07-20020 July 1987 Insp Rept 70-1257/87-05 on 870606-12 & 0701.No Violations Noted.Major Areas Inspected:Mgt Organization & Controls, Criticality Safety,Operations Review,Transportation/Radwaste Mgt & Emergency Preparedness & Environ Protection ML20215C0731986-12-0808 December 1986 Partially Withheld Matl Control & Accounting Insp Rept 70-1257/86-09 on 861117-21 (Ref 10CFR2.790).No Violations or Deviations Identified.Major Areas Inspected:Followup on inspector-identified Problems & Unresolved Items ML20212K8191986-08-14014 August 1986 Insp Rept 70-1257/86-05 on 860721-25.Violation Noted:While Performing Equipment Maint,Electrician Spilled Uncontained Visible UO2 Powder Which Was Not Reported to Hpt ML20199C6741986-06-13013 June 1986 Insp Rept 70-1257/86-03 on 860512-16.No Violations Noted. Major Areas Inspected:Mgt Organization & Controls,Training & Retraining,Criticality Safety,Operations Review,Maint & Surveillance Testing & Radiation Protection ML20198J5571986-05-27027 May 1986 Partially Withheld Insp Rept 70-1257/86-04 on 860505-09 (Ref 10CFR2.790).No Violation or Deviation Noted.Major Areas Inspected:Followup on inspector-identified Problems & Unresolved Items ML20154Q8671986-03-13013 March 1986 Matl Control & Accounting Insp Rept 70-1257/86-01 on 860210-14 & 25.No Violations Noted.Major Areas Inspected: Facility Organization & Mgt Controls,Measurement Sys & Matl Control.Details Withheld (Ref 10CFR2.790) ML20154K2321986-02-26026 February 1986 Insp Rept 70-1257/86-02 on 860203-07 & 20.Violations Noted: Procedure Specified That Valves Be Tested Between 70 & 90 Psig Instead of 100 Psig & Protective Valve Cover on Cylinder Not Used After Removal from Vaporization Chest ML20136J0301986-01-0606 January 1986 Insp Rept 70-1257/85-13 on 851203-06 & 09-20.No Violations or Deviations Noted.Major Areas Inspected:Facility Organization & Mgt Controls & Facility Operations & Internal Control.Details Withheld (Ref 10CFR2.790) ML20138A7671985-12-0606 December 1985 Insp Rept 70-1257/85-12 on 851105-25.No Violations Noted. Major Areas Inspected:Mgt Organization & Controls,Training & Retraining,Criticality Safety,Operations Review & Maint & Surveillance Testing ML20135A3351985-08-21021 August 1985 Insp Rept 70-1257/85-10 on 850729-0802.Violation Noted: Visible Hole Identified on Bottom of Container in Shipment ML20127M3021985-06-20020 June 1985 Matl Control & Accountability Safeguards Insp Rept 70-1257/85-08 on 850528-30 & 0603-07.No Violations Noted. Major Areas Inspected:Facility Operations & Internal Control.Details Withheld (Ref 10CFR2.790) ML20127A4411985-06-14014 June 1985 Physical Security Insp Rept 70-1257/85-07 on 850603-07.No Noncompliance Noted.Major Areas Inspected:Physical Protection of SNM of Low Strategic Significance.Details Withheld (Ref 10CFR2.790) ML20126F5071985-06-10010 June 1985 Insp Rept 70-1257/85-06 on 850513-17.No Violation Noted. Major Areas Inspected:Mgt Organization & Controls,Operator Training & Retraining,Maint & Surveillance Testing,Radiation Protection & Radwaste Mgt ML20125B6451985-06-0505 June 1985 Safeguards Insp Rept 70-1257/85-05 on 850506-10 & 21.No Violation Noted.Major Areas Inspected:Periodic & Special Repts,Facility Organization & Mgt Control & Facility Operations.Details Withheld (Ref 10CFR2.790) ML20140E3811984-12-14014 December 1984 Insp Rept 70-1257/84-10 on 841105-09.No Violations Identified.Major Areas Inspected:Violation Corrections,Mgt Organization & Controls,Operator Training & Retraining, Criticality Safety & Operations Review ML20028A5711982-10-26026 October 1982 IE Insp Rept 70-1257/82-09 on 820920-22.No Noncompliance Noted.Major Areas Inspected:Facility Changes & Mods,Internal Review & Audit,Criticality Safety,Operations Review & Emergency Planning ML20027B3701982-09-15015 September 1982 IE Safeguards Insp Rept 70-1257/82-06 on 820802-06 & 0909-13.No Noncompliance Noted.Major Areas Inspected: Independent Safeguards Insp Effort & Measurement & Controls. Details Withheld (Ref 10CFR2.790) ML20053D1841982-05-24024 May 1982 IE Safeguards Insp Rept 70-1257/82-04 on 820414-21.No Noncompliance Noted.Major Areas Inspected:Physical Inventory on Verification Per IAEA Safeguards Agreement. Details Withheld (Ref 10CFR2.790 & 10CFR73.21) ML20054D8131982-04-0505 April 1982 IE Insp Rept 70-1257/82-03 on 820301-04.No Noncompliance Noted.Major Areas Inspected:Organization,Facility Changes & Mods,Internal Audit & Review,Safety Committee Activities, Employee Training & Operation Review ML20011A8931981-10-28028 October 1981 IE Insp Rept 70-1257/81-05 on 810720-24.No Noncompliance Noted.Major Areas Inspected:Safeguards Insp for Compliance W/Applicable Regulations Re Control & Accounting of Snm. Details Withheld (Ref 10CFR2.790) ML20031A5401981-09-10010 September 1981 IE Insp Rept 70-1257/81-06 on 810812-14.No Noncompliance Noted.Major Areas Inspected:Program for Implementation of IAEA Safeguard Insp at Fuel Fabrication Site.Details Withheld (Ref 10CFR2.790) ML20031A4481981-08-21021 August 1981 IE Insp Rept 70-1257/81-04 on 810713-16.No Noncompliance Noted.Major Areas Inspected:Organization,Internal Review & Audit,Safety Committee Activities,Operations Review, Radiation Protection & Radwaste Mgt ML20126L3961981-04-16016 April 1981 IE Insp Rept 70-1257/81-03 on 810312-13.Noncompliance Noted: Matls Transported on 810310 in Exclusive Use Vehicles Not Packaged in Strong Tight Packages.Waste Packaging Papers Encl ML19345D1251980-10-14014 October 1980 IE Insp Rept 70-1257/80-07 on 800812-15.No Noncompliance Noted.Major Areas Inspected:Licensee Use of Lagoons for Storage & Evaporation of Liquid Process Wastes,Lagoon Monitoring & Possible Environ Impact ML19321A8821980-06-10010 June 1980 IE Insp Rept 70-1257/80-04 on 800331,0401 & 22-23.No Noncompliance Noted.Major Areas Inspected:Facility Mods, Radwaste Mgt & Internal Review & Audit ML19249B3611979-07-19019 July 1979 IE Insp Rept 70-1257/79-06 on 790611-15.No Noncompliance Noted.Major Areas Inspected:Employee Training,Operations Review,Criticality Safety,Radiation Protection,Radioactive Waste Mgt & Transportation Program ML19276G1611979-03-16016 March 1979 IE Insp Rept 70-1257/79-01 on 790212-16.No Noncompliance Noted.Major Areas Inspected:Safety Committee Activities, Training,Calibr,Criticality Safety,Emergency Planning & Fire & Radiation Protection 1990-09-05
[Table view] Category:INSPECTION REPORT
MONTHYEARML24211A0592024-07-29029 July 2024 Framatome Inc. – Physical Security Core Inspection Report 07001257-2024401 Public ML24190A0292024-07-19019 July 2024 Framatome - Richland - Core Inspection Report 07001257/2024002 ML24116A2922024-04-29029 April 2024 Framatome-Richland - Core Inspection Report 07001257/2024001 ML24026A2792024-01-31031 January 2024 Framatome - Richland – Integrated Inspection Report 07001257/2023004 ML23296A0072023-10-25025 October 2023 Framatome-Richland - Core Inspection Report 07001257/2023003 ML23202A2022023-07-24024 July 2023 Framatome Richland Core Inspection Report 07001257/2023002 ML23089A2592023-04-10010 April 2023 2023-001 Framatome-Richland - NRC Integrated Inspection Report 07001257/2023001 ML23030B6172023-01-31031 January 2023 Framatome-Richland - Core Inspection Report 07001257/2022004 ML22291A0342022-10-17017 October 2022 Framatome Inspection Request (2022 Nuclear Criticality and Emergency Preparedness) ML22201A5352022-07-21021 July 2022 Framatome 2022-002 Integrated Quarterly Inspection Report ML22024A2152022-01-25025 January 2022 Framatome, Inc. - Richland, U.S. Nuclear Regulatory Commission Integrated Inspection Report 07001257/2021004 ML21298A2242021-10-25025 October 2021 Framatome-Richland Integrated Inspection Report 07001257/2021003 ML21237A3092021-08-25025 August 2021 Framatome - Material Control and Accounting Program Inspection Report 07001257/2021401 (OUO Removed) ML21221A1852021-08-0606 August 2021 NRC Doc Request Fram OPS-PMA IR 2021-003 ML21189A0042021-07-0707 July 2021 Framatome-Richland Integrated Inspection Report 07001257/2021002 ML21113A2292021-04-23023 April 2021 Framatome - Richland, U.S. Nuclear Regulatory Commission Inspection Report Number 70-1257/2021-001 ML21025A2902021-01-22022 January 2021 Framatome Inc. - U. S. Nuclear Regulatory Commission Integrated Inspection Report 07001257/2020004 ML20303A2512020-10-29029 October 2020 Framatome, Inc. - U.S. Nuclear Regulatory Commission Integrated Inspection Report Number 70-1257/2020-003 ML20302A4312020-10-28028 October 2020 Framatome Inc., U.S. Nuclear Regulatory Commission Inspection Report 2020-401 Public ML20184A2822020-07-0202 July 2020 Framatome Inc., - NRC Integrated Inspection Report 701257/2020001 and 701257/2020-002 ML20030A2612020-01-29029 January 2020 Framatome Quarterly IR 2019-005 ML19301A0762019-10-25025 October 2019 Framatome Inc. - U. S. Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2019-004 ML19214A1162019-08-0202 August 2019 Framatome, Inc., Nuclear Regulatory Commission Integrated Inspection Report 07001257/2019003 ML19109A0022019-04-17017 April 2019 Framatome Quarterly IR 2019-002 ML19025A0172019-01-25025 January 2019 Framatome, Inc. - Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2018-005 ML18297A0902018-10-24024 October 2018 Framatome Quarterly IR 2018-004 ML18200A2402018-07-19019 July 2018 Framatome Inc., - Nuclear Regulatory Integrated Inspection Report 07001257/2018003 ML18110A0232018-04-20020 April 2018 Framatome Inc., - Nuclear Regulatory Commission Integrated Inspection Report 70-1257/2018002 ML18025B2502018-01-25025 January 2018 Framatome Inc., - NRC Integrated Inspection Report 0701257/2017005 ML1100306952010-12-30030 December 2010 IR 70-1257-10-010 & Notice of Violation, on 11/18/10, Areva Np, Inc., Richland ML20211G7501999-08-25025 August 1999 Partially Withheld Insp Rept 70-1257/99-201 (Ref 10CFR2.790) on 990802-05.No Violations Noted.Major Areas Inspected:Exams of Core Procedures & Representative Records & Interviews with Personnel.Details Withheld ML20211B9261999-08-19019 August 1999 Insp Rept 70-1257/99-202 on 990802-05.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Safety Training,Administrative Controls,Internal Audits & Internal Reporting of Nuclear Criticality Safety Infractions ML20210R9071999-08-12012 August 1999 Insp Rept 70-1257/99-02 on 990712-16.No Violations Noted. Major Areas Inspected:Selected Aspects of Licensee Programs for Operational Safety,Radioactive Effluents,Environ Protection,Waste Mgt Programs & Followup of Open Items ML20207B3781999-05-21021 May 1999 Insp Rept 70-1257/99-01 on 990322-26,0514 & 21.Violations Noted.Major Areas Inspected;Licensee Programs for Radiation Protection,Emergency Preparedness,Operator Training, Transportation & Followup of Open Items from Previous Insps ML20198F6021998-12-15015 December 1998 Insp Rept 70-1257/98-05 on 981026-30.No Violations Noted. Major Areas Inspected:Operations,Operational Event Review Feedback & Mgt Organization ML20198B4361998-12-14014 December 1998 Insp Rept 70-1257/98-204 on 981109-13.Violation Noted. Major Areas Inspected:Open Item Completion,Review of Recent Licensee Criticality Safety Event,Validation & Criticality Safety Analysis ML20151X0721998-09-16016 September 1998 Insp Rept 70-1257/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Operational Safety,Maint & Surveillance,Transportation & follow-up of Open Items from Previous Insps ML20236R2841998-07-17017 July 1998 Insp Rept 70-1257/98-03 on 980615-19.Violations Noted.Major Areas Inspected:Selected Aspects of Operational Safety, Radiation Protection,Radioactive Waste Handling & Storage ML20248K0011998-06-0202 June 1998 Insp Rept 70-1257/98-02 on 980413-17 & 980504-08.No Violations Noted.Major Areas Inspected:Operational Safety, Radioactive Effluents & Environ Protection ML20217J8671998-04-0101 April 1998 Insp Rept 70-1257/98-201 on 980313-19.Violations Noted.Major Areas Inspected:Open Item Resolution,Configuration Mgt & Flowdown of Analytical Limits & Controls ML20203K3731998-02-24024 February 1998 Insp Rept 70-1257/98-01 on 980126-30.No Violations Noted. Major Areas Inspected:Review of Mgt Organization & Controls, Operational Event Review & Feedback,Operator Training & Qualification & Selected Aspects of Operational Safety ML20198S5181998-01-16016 January 1998 Insp Rept 70-1257/97-07 on 971215-19 & 971222-24.Violations Noted.Major Areas Inspected:Ep,Operations & Followup on Open Items from Previous Insps ML20199B9431997-11-0707 November 1997 Insp Rept 70-1257/97-202 on 971006-10.Violation Noted.Major Areas Inspected:Criticality Safety Analyses,Chemical Safety Assessment,Chemical & Criticality Safety Controls,Active Engineering Controls & Administrative Controls Flowdown ML20217G9641997-10-0808 October 1997 Insp Rept 70-1257/97-06 on 970915-19.No Violations Noted. Major Areas Inspected:Selected Aspects of Operations & Radiation Protection ML20198H4171997-09-0505 September 1997 Insp Rept 70-1257/97-201 on 970804-08.No Violations Noted. Info Re Major Areas Inspected Withheld,Per 10CFR2.790(d) ML20046D7991997-09-0505 September 1997 Non-proprietary Cover Sheet to Insp Rept 70-1257/97-201 on 970804-08.Details of Rept Withheld,Per 10CFR2.790(d) ML20141K5791997-05-23023 May 1997 Insp Rept 70-1257/97-04 on 970414-18,23,24 & 0501.Violations Noted.Major Areas Inspected:Operations,Radioactive Effluent Discharges,Environ Protection,Solid Radioactive Waste Mgt & Transportation of Radioactive Matls ML20137P1301997-04-0404 April 1997 Insp Rept 70-1257/97-03 on 970303-07.No Violations Noted. Major Areas Inspected:Aspects of Plant Operations, Engineering,Maint & Surveillance Testing ML20136C1611997-03-0707 March 1997 Insp Rept 70-1257/97-02 on 970210-12.No Violation Noted. Major Areas Inspected:Physical Security Plan,Safeguards Events,Fixed Site Physical Protection of Special Nuclear Matl of Low Strategic Significance & Insp Folloup Item ML20134C7331997-01-30030 January 1997 Insp Rept 70-1257/97-01 on 970106-10.Violation Noted.Major Areas Inspected:Mgt Organization & Controls,Operator Training & Qualification,Plant Operations & Engineering 2024-07-29
[Table view] Category:NRC-GENERATED
MONTHYEARML20211G7501999-08-25025 August 1999 Partially Withheld Insp Rept 70-1257/99-201 (Ref 10CFR2.790) on 990802-05.No Violations Noted.Major Areas Inspected:Exams of Core Procedures & Representative Records & Interviews with Personnel.Details Withheld ML20211B9261999-08-19019 August 1999 Insp Rept 70-1257/99-202 on 990802-05.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Safety Training,Administrative Controls,Internal Audits & Internal Reporting of Nuclear Criticality Safety Infractions ML20210R9071999-08-12012 August 1999 Insp Rept 70-1257/99-02 on 990712-16.No Violations Noted. Major Areas Inspected:Selected Aspects of Licensee Programs for Operational Safety,Radioactive Effluents,Environ Protection,Waste Mgt Programs & Followup of Open Items ML20207B3781999-05-21021 May 1999 Insp Rept 70-1257/99-01 on 990322-26,0514 & 21.Violations Noted.Major Areas Inspected;Licensee Programs for Radiation Protection,Emergency Preparedness,Operator Training, Transportation & Followup of Open Items from Previous Insps ML20198F6021998-12-15015 December 1998 Insp Rept 70-1257/98-05 on 981026-30.No Violations Noted. Major Areas Inspected:Operations,Operational Event Review Feedback & Mgt Organization ML20198B4361998-12-14014 December 1998 Insp Rept 70-1257/98-204 on 981109-13.Violation Noted. Major Areas Inspected:Open Item Completion,Review of Recent Licensee Criticality Safety Event,Validation & Criticality Safety Analysis ML20151X0721998-09-16016 September 1998 Insp Rept 70-1257/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Operational Safety,Maint & Surveillance,Transportation & follow-up of Open Items from Previous Insps ML20236R2841998-07-17017 July 1998 Insp Rept 70-1257/98-03 on 980615-19.Violations Noted.Major Areas Inspected:Selected Aspects of Operational Safety, Radiation Protection,Radioactive Waste Handling & Storage ML20248K0011998-06-0202 June 1998 Insp Rept 70-1257/98-02 on 980413-17 & 980504-08.No Violations Noted.Major Areas Inspected:Operational Safety, Radioactive Effluents & Environ Protection ML20217J8671998-04-0101 April 1998 Insp Rept 70-1257/98-201 on 980313-19.Violations Noted.Major Areas Inspected:Open Item Resolution,Configuration Mgt & Flowdown of Analytical Limits & Controls ML20203K3731998-02-24024 February 1998 Insp Rept 70-1257/98-01 on 980126-30.No Violations Noted. Major Areas Inspected:Review of Mgt Organization & Controls, Operational Event Review & Feedback,Operator Training & Qualification & Selected Aspects of Operational Safety ML20198S5181998-01-16016 January 1998 Insp Rept 70-1257/97-07 on 971215-19 & 971222-24.Violations Noted.Major Areas Inspected:Ep,Operations & Followup on Open Items from Previous Insps ML20199B9431997-11-0707 November 1997 Insp Rept 70-1257/97-202 on 971006-10.Violation Noted.Major Areas Inspected:Criticality Safety Analyses,Chemical Safety Assessment,Chemical & Criticality Safety Controls,Active Engineering Controls & Administrative Controls Flowdown ML20217G9641997-10-0808 October 1997 Insp Rept 70-1257/97-06 on 970915-19.No Violations Noted. Major Areas Inspected:Selected Aspects of Operations & Radiation Protection ML20198H4171997-09-0505 September 1997 Insp Rept 70-1257/97-201 on 970804-08.No Violations Noted. Info Re Major Areas Inspected Withheld,Per 10CFR2.790(d) ML20046D7991997-09-0505 September 1997 Non-proprietary Cover Sheet to Insp Rept 70-1257/97-201 on 970804-08.Details of Rept Withheld,Per 10CFR2.790(d) ML20141K5791997-05-23023 May 1997 Insp Rept 70-1257/97-04 on 970414-18,23,24 & 0501.Violations Noted.Major Areas Inspected:Operations,Radioactive Effluent Discharges,Environ Protection,Solid Radioactive Waste Mgt & Transportation of Radioactive Matls ML20137P1301997-04-0404 April 1997 Insp Rept 70-1257/97-03 on 970303-07.No Violations Noted. Major Areas Inspected:Aspects of Plant Operations, Engineering,Maint & Surveillance Testing ML20136C1611997-03-0707 March 1997 Insp Rept 70-1257/97-02 on 970210-12.No Violation Noted. Major Areas Inspected:Physical Security Plan,Safeguards Events,Fixed Site Physical Protection of Special Nuclear Matl of Low Strategic Significance & Insp Folloup Item ML20134C7331997-01-30030 January 1997 Insp Rept 70-1257/97-01 on 970106-10.Violation Noted.Major Areas Inspected:Mgt Organization & Controls,Operator Training & Qualification,Plant Operations & Engineering ML20133D0291997-01-0303 January 1997 Insp Rept 70-1257/96-206 on 961202-05.Violations Noted. Major Areas Inspected:Fuel Fabrication Facility in Richland,Wa,Activities Associated W/Planned Startup of New Dry Conversion Facility & Review of Hq Insp Procedure 88015 ML20135D8221996-12-0505 December 1996 Insp Rept 70-1257/96-205 on 961104-07.No Violations Noted. Details Withheld ML20134K8161996-11-12012 November 1996 Insp Rept 70-1257/96-04 on 961021-25.Violations Noted.Major Areas Inspected:Emergency Preparedness,Fp,Followup on Licensee Events & Followup on Open Item from Previous Item ML20149H4771994-11-0202 November 1994 Insp Rept 70-1257/94-06 on 940926-30 & 1012-14.Violations Noted.Major Areas Inspected:Review Circumstances Re 940918 Event,Involving Spill of Approx 41 Kg of Low Enriched U Dioxide Power ML20058H9321993-11-22022 November 1993 Insp Rept 70-1257/93-12 on 931101-05.No Violations Noted. Major Areas Inspected:Fire Protection & Followup on Items of Noncompliance,Inspector Followup Items & NRC Info Notices ML20058D4261993-10-17017 October 1993 Insp Rept 70-1257/93-11 on 930908 & 0927-1001.No Violations or Deviations Noted.Major Areas Inspected:Criticality Safety,Operations & Followup on Open Items ML20057C5041993-08-26026 August 1993 Insp Rept 70-1257/93-10 on 930812.No Violations Noted.Major Areas Inspected:Announced Insp to Obtain Info on Licensee Employee Concerns Program ML20046D3401993-08-12012 August 1993 Partially Withheld Insp Rept 70-1257/93-201 on 930712-16. Details Withheld (Ref 10CFR2.790.) ML20056E4111993-08-0808 August 1993 Insp Rept 70-1257/93-09 on 930726-30.Violations Noted But Not Cited.Major Areas Inspected:Maint/Surveillance Testing, Radiation Protection,Criticality Safety/Operations Review, Environ/Waste Mgt & Followup on Open Items ML20056E9041993-08-0404 August 1993 Insp Rept 70-1257/93-08 on 930628-0702.No Violations Noted. Major Areas Inspected:Review Licensee Emergency Preparedness Program & Followup on Open Items ML20056C8711993-07-0707 July 1993 Insp Rept 70-1257/93-07 on 930614-18.No Violations Noted. Major Areas Inspected:Environ Protection,Radwaste Mgt, Onsite Followup of Licensee Events & Followup on Open Items ML20045C6081993-06-0707 June 1993 Insp Rept 70-1257/93-03 on 930412-16.Violations Noted.Major Areas Inspected:Mgt/Organization,Training/Qualification, Transportation of Radioactive Matls & Waste Generator Requirements ML20045C2041993-06-0101 June 1993 Enforcement Conference Rept 70-1257/93-06 on 930517.Major Areas Discussed:Apparent Violations Identified During AIT Insp (NRC Insp Rept 70-1257/93-02) & in-ofc Review of AIT Findings (NRC Insp Rept 70-1257/93-05),dtd 930430 ML20044G1211993-05-19019 May 1993 Insp Rept 70-1257/93-04 on 930226-0409.Violations Noted. Major Areas Inspected:Control Room Operations,Licensee Action on Previous Insp Findings,Criticality Safety Controls Radiological Controls & Special Insp Topics ML20035A0861993-03-10010 March 1993 Insp Rept 70-1257/93-02 on 930209-12.Enforcement Issues Not Addressed.Major Areas Inspected:Circumstances & Cause of 930207 Event Re Inadvertent Accumulation of 124 Kg Low Enriched U Oxide Powder Inside Lexan Encl ML20035B7281993-03-0909 March 1993 Insp Rept 70-1257/93-01 on 930204-11.Violations Noted.Major Areas Inspected:Radiation Protection Program Including Procedures,Instrument & Equipment & Contamination Surveys ML20127B1621992-12-23023 December 1992 Insp Rept 70-1257/92-09 on 921207-11.No Violations or Deviations Noted.Major Areas Inspected:Fire Protection & Followup on Items of Noncompliance,Inspector Followup Items & NRC Info Notices ML20126B3451992-12-0404 December 1992 Insp Rept 70-1257/92-08 on 921015-17 & 29.Violations Noted. Major Areas Inspected:Overflow of Low Enriched Uranyl Fluoride to U Hexafluoride Vaporization Chest ML20024H2481991-05-23023 May 1991 Partially Withheld Physical Security Insp Rept 70-1257/91-02 on 910422-0508 (Ref 10CFR2.790(d)).No Violations or Deviations Noted.Major Areas Inspected:Plans,Procedures & Reviews,Safeguards Event Repts & Protection of SNM ML20059H9681990-09-0505 September 1990 Partially Withheld Insp Rept 70-1257/90-201 on 900806-10 (Ref 10CFR2.790(d)).No Violations,Deviations or Declining Performance Identified.Major Areas Inspected:Physical Inventory & Measurement Control ML20059G8981990-08-31031 August 1990 Insp Rept 70-1257/90-03 on 900813-17.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection, Maint & Surveillance Testing,Transportation of Radioactive Matls & Criticality Safety ML20012B8131990-03-0202 March 1990 Insp Rept 70-1257/90-01 900108-12 & 0205-09.Violations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Mgt & Organization,Operator Training/Retraining, Criticality Safety & Operations Review ML19324C3071989-11-0808 November 1989 Insp Rept 70-1257/89-03 on 890925-29.Violations Noted.Major Areas Inspected:Criticality Safety,Operations Review,Maint & Surveillance Testing,Radwaste Mgt,Environ Protection, Emergency Preparedness & Radwaste Generator Requirements ML20245H0751989-08-0909 August 1989 Matl Control & Accounting Insp Rept 70-1257/89-201 on 890612-21.No Violations,Deviations or Declining Performance Identified.Major Areas Inspected:Measurement Sys,Physical Inventory & Records & Repts ML20247H6391989-05-22022 May 1989 Insp Rept 70-1257/89-02 on 890417-21.No Violations Noted. Major Areas Inspected:Followup Actions on Open Items,Mgt Organization,Training & Retraining,Criticality Safety, Operations Review & Radiation Protection ML20247P5161989-04-0505 April 1989 Insp Rept 70-1257/89-200 on 890306-10.No Violations or Deviations Noted.Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys,Measurement Controls & Matl Control & Accounting for Exports & Imports ML20195F9841988-11-18018 November 1988 Insp Rept 70-1257/88-08 on 880906-09 & 23.Violations Noted. Major Areas Inspected:Mgt Organization,Training & Retraining,Criticality Safety,Operations Review,Maint & Surveillance Testing ML20154J6151988-05-12012 May 1988 Insp Rept 70-1257/88-04 on 880418-22.No Violations Noted. Major Areas Inspected:Mgt Organization,Criticality Safety, Operations Review,Maint & Surveillance Testing & Radwaste Mgt ML20236C9151987-10-20020 October 1987 Insp Rept 70-1257/87-08 on 870928-1002.No Violations Noted. Major Areas Inspected:Mgt Organization & Controls, Criticality Safety,Operations Review,Training,Radiation Protection & Emergency Preparedness & Environ Protection ML20235X1551987-07-20020 July 1987 Insp Rept 70-1257/87-05 on 870606-12 & 0701.No Violations Noted.Major Areas Inspected:Mgt Organization & Controls, Criticality Safety,Operations Review,Transportation/Radwaste Mgt & Emergency Preparedness & Environ Protection 1999-08-25
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARML20211G7501999-08-25025 August 1999 Partially Withheld Insp Rept 70-1257/99-201 (Ref 10CFR2.790) on 990802-05.No Violations Noted.Major Areas Inspected:Exams of Core Procedures & Representative Records & Interviews with Personnel.Details Withheld ML20211B9261999-08-19019 August 1999 Insp Rept 70-1257/99-202 on 990802-05.No Violations Noted. Major Areas Inspected:Plant Operations,Criticality Safety Training,Administrative Controls,Internal Audits & Internal Reporting of Nuclear Criticality Safety Infractions PNO-IV-99-036, on 990813,licensee Notified NRC Operations Ctr That Inaccurate Lab Analysis Method Resulted in Potential for Criticality Safety Limit to Be Exceeded by 23%.Affected Process Was Shut Down & Tagged Out.Region Will Conduct Insp1999-08-18018 August 1999 PNO-IV-99-036:on 990813,licensee Notified NRC Operations Ctr That Inaccurate Lab Analysis Method Resulted in Potential for Criticality Safety Limit to Be Exceeded by 23%.Affected Process Was Shut Down & Tagged Out.Region Will Conduct Insp ML20210R9071999-08-12012 August 1999 Insp Rept 70-1257/99-02 on 990712-16.No Violations Noted. Major Areas Inspected:Selected Aspects of Licensee Programs for Operational Safety,Radioactive Effluents,Environ Protection,Waste Mgt Programs & Followup of Open Items ML20207B3781999-05-21021 May 1999 Insp Rept 70-1257/99-01 on 990322-26,0514 & 21.Violations Noted.Major Areas Inspected;Licensee Programs for Radiation Protection,Emergency Preparedness,Operator Training, Transportation & Followup of Open Items from Previous Insps ML20207B3731999-05-21021 May 1999 Notice of Violation from Insp on 990322-26,0514 & 21. Violations Noted:On 980225,licensee Delivered Licensed Matl to Carrier for Transport Under General License Pursuant to 10CFR71.12 & Did Not Comply with Terms & Conditions PNO-III-99-005, on 990202,truck with Empty UF6 Cylinders Involved in Traffic Accident.Local Fire & Police Personnel Responded Immediately to Scene of Accident.Driver of tractor-trailer Received Minor Injuries1999-02-0303 February 1999 PNO-III-99-005:on 990202,truck with Empty UF6 Cylinders Involved in Traffic Accident.Local Fire & Police Personnel Responded Immediately to Scene of Accident.Driver of tractor-trailer Received Minor Injuries ML20198F6021998-12-15015 December 1998 Insp Rept 70-1257/98-05 on 981026-30.No Violations Noted. Major Areas Inspected:Operations,Operational Event Review Feedback & Mgt Organization ML20198B4361998-12-14014 December 1998 Insp Rept 70-1257/98-204 on 981109-13.Violation Noted. Major Areas Inspected:Open Item Completion,Review of Recent Licensee Criticality Safety Event,Validation & Criticality Safety Analysis ML20198B4191998-12-14014 December 1998 Notice of Violation from Insp on 981109-13.Violation Noted: Failure to Control Decommissioning Operations So That Operators Would Verify That Disassembled Equipment Was Free from Visible U Deposits Before Staging with Other Equipment PNO-IV-98-043, on 980922,NRC Operation Ctr Notified That Criticality Safety Specialist Noted Visible Accumulations of Solids in Disassembled Sections of Ductwork.Training Planned for Disassembly Crew in Aspects of Safety Requirements1998-09-23023 September 1998 PNO-IV-98-043:on 980922,NRC Operation Ctr Notified That Criticality Safety Specialist Noted Visible Accumulations of Solids in Disassembled Sections of Ductwork.Training Planned for Disassembly Crew in Aspects of Safety Requirements ML20151X0721998-09-16016 September 1998 Insp Rept 70-1257/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Operational Safety,Maint & Surveillance,Transportation & follow-up of Open Items from Previous Insps ML20236R2741998-07-17017 July 1998 Notice of Violation from Insp on 980615-19.Violation Noted: Operational Safety Activities Not Implemented Iaw/Documented Standard Operating Procedures Appropriate to Circumstances in Listed Examples ML20236R2841998-07-17017 July 1998 Insp Rept 70-1257/98-03 on 980615-19.Violations Noted.Major Areas Inspected:Selected Aspects of Operational Safety, Radiation Protection,Radioactive Waste Handling & Storage PNO-IV-98-022, on 980605,notified Nrc,Region IV That Mfg Sciences Corp Had Returned Shipment of Zirconium Cladding After Discovery of Two Unirradiated Fuel Pellets within Cladding.Nrc Region IV Will Perform follow-up Review1998-06-0505 June 1998 PNO-IV-98-022:on 980605,notified Nrc,Region IV That Mfg Sciences Corp Had Returned Shipment of Zirconium Cladding After Discovery of Two Unirradiated Fuel Pellets within Cladding.Nrc Region IV Will Perform follow-up Review ML20248K0011998-06-0202 June 1998 Insp Rept 70-1257/98-02 on 980413-17 & 980504-08.No Violations Noted.Major Areas Inspected:Operational Safety, Radioactive Effluents & Environ Protection PNO-IV-98-017A, on 980415,licensee Conducted Conducted Briefing of Region IV & Headquarters Staff on Details of Fire.Location & Matls Involved in Fire,Described in Original Preliminary Notification of Event or Unusual Occurrence1998-04-16016 April 1998 PNO-IV-98-017A:on 980415,licensee Conducted Conducted Briefing of Region IV & Headquarters Staff on Details of Fire.Location & Matls Involved in Fire,Described in Original Preliminary Notification of Event or Unusual Occurrence PNO-IV-98-017, on 980415,licensee Reported to NRC Operations Ctr That Fire Had Occurred in Handling Area of UO2 Bldg.Fire Initially Quelled w/CO2 & Then Extinguished W/Small Amount of Water.Licensee Scheduled to Conduct Briefing W/Nrc1998-04-15015 April 1998 PNO-IV-98-017:on 980415,licensee Reported to NRC Operations Ctr That Fire Had Occurred in Handling Area of UO2 Bldg.Fire Initially Quelled w/CO2 & Then Extinguished W/Small Amount of Water.Licensee Scheduled to Conduct Briefing W/Nrc ML20217J8671998-04-0101 April 1998 Insp Rept 70-1257/98-201 on 980313-19.Violations Noted.Major Areas Inspected:Open Item Resolution,Configuration Mgt & Flowdown of Analytical Limits & Controls ML20203K3731998-02-24024 February 1998 Insp Rept 70-1257/98-01 on 980126-30.No Violations Noted. Major Areas Inspected:Review of Mgt Organization & Controls, Operational Event Review & Feedback,Operator Training & Qualification & Selected Aspects of Operational Safety ML20198S4961998-01-16016 January 1998 Notice of Violation from Insp on 971215-19 & 971222-24. Violation Noted:On 971218,licensee Discovered That U Compounds Other than Oxide Pellets Were Being Stored in Temporary Storage Locations ML20198S5181998-01-16016 January 1998 Insp Rept 70-1257/97-07 on 971215-19 & 971222-24.Violations Noted.Major Areas Inspected:Ep,Operations & Followup on Open Items from Previous Insps ML20199B9431997-11-0707 November 1997 Insp Rept 70-1257/97-202 on 971006-10.Violation Noted.Major Areas Inspected:Criticality Safety Analyses,Chemical Safety Assessment,Chemical & Criticality Safety Controls,Active Engineering Controls & Administrative Controls Flowdown ML20199B9341997-11-0707 November 1997 Notice of Violation from Insp on 971006-10.Violation Noted: April 1977 Loss of Moisture Control Incident at Dry Conversion Pilot Plant Was Not Adequately Reviewed & Appropriate Corrective Actions Were Not Taken ML20217G9641997-10-0808 October 1997 Insp Rept 70-1257/97-06 on 970915-19.No Violations Noted. Major Areas Inspected:Selected Aspects of Operations & Radiation Protection PNO-IV-97-053, on 970917,Siemens Nuclear Corp Reported Discovery of Damp U Dioxide Matl in Transfer Line in Dry Conversion Pilot Facility Sample Analyses of Pyrohyrolysis Vessel.Licensee Rept Made,Per NRC Bulletin 91-0011997-09-18018 September 1997 PNO-IV-97-053:on 970917,Siemens Nuclear Corp Reported Discovery of Damp U Dioxide Matl in Transfer Line in Dry Conversion Pilot Facility Sample Analyses of Pyrohyrolysis Vessel.Licensee Rept Made,Per NRC Bulletin 91-001 ML20216J0851997-09-12012 September 1997 Notice of Violation from Insp on 970731.Violation Noted: on 970413,RL Rumley,Lead Operator,Defeated Breathing Zone Air Sampler by Placing Rubber Glove Over Air Sampler at Respective Work Station ML20046D7991997-09-0505 September 1997 Non-proprietary Cover Sheet to Insp Rept 70-1257/97-201 on 970804-08.Details of Rept Withheld,Per 10CFR2.790(d) ML20198H4171997-09-0505 September 1997 Insp Rept 70-1257/97-201 on 970804-08.No Violations Noted. Info Re Major Areas Inspected Withheld,Per 10CFR2.790(d) ML20141K5781997-05-23023 May 1997 Notice of Violation from Insp on 970414-18,23,24 & 0501. Violation Noted:On 960603,licensee Shipped 405 NT-IX Shipping Packages Containing Fissile Matl W/O Installing Cushioning Matl ML20141K5791997-05-23023 May 1997 Insp Rept 70-1257/97-04 on 970414-18,23,24 & 0501.Violations Noted.Major Areas Inspected:Operations,Radioactive Effluent Discharges,Environ Protection,Solid Radioactive Waste Mgt & Transportation of Radioactive Matls ML20137P1301997-04-0404 April 1997 Insp Rept 70-1257/97-03 on 970303-07.No Violations Noted. Major Areas Inspected:Aspects of Plant Operations, Engineering,Maint & Surveillance Testing ML20136C1611997-03-0707 March 1997 Insp Rept 70-1257/97-02 on 970210-12.No Violation Noted. Major Areas Inspected:Physical Security Plan,Safeguards Events,Fixed Site Physical Protection of Special Nuclear Matl of Low Strategic Significance & Insp Folloup Item ML20134C7331997-01-30030 January 1997 Insp Rept 70-1257/97-01 on 970106-10.Violation Noted.Major Areas Inspected:Mgt Organization & Controls,Operator Training & Qualification,Plant Operations & Engineering ML20134C7241997-01-30030 January 1997 Notice of Violation from Insp on 970106-10.Violation Noted: Field Change Made Under Open ECN (No.5533L) & Not Documented or Included W/Ecn Package Prior to Startup Approval on 960806 PNO-III-97-004, on 970124,truck Carrying Four U Hexafluoride Cylinders in Accident Occurred.Truck Transporting Cylinders from Portsmouth Gaseous Diffusion Plant to Siemens Power Corp in Richland,Washington1997-01-24024 January 1997 PNO-III-97-004:on 970124,truck Carrying Four U Hexafluoride Cylinders in Accident Occurred.Truck Transporting Cylinders from Portsmouth Gaseous Diffusion Plant to Siemens Power Corp in Richland,Washington ML20133D0231997-01-0303 January 1997 Notice of Violation from Insp on 961202-05.Violation Noted: Licensee Failed to Update Posted Criticality Safety Limit Card for UF6 Cylinder Wash Operation to Reflect Change in CCS Limit ML20133D0291997-01-0303 January 1997 Insp Rept 70-1257/96-206 on 961202-05.Violations Noted. Major Areas Inspected:Fuel Fabrication Facility in Richland,Wa,Activities Associated W/Planned Startup of New Dry Conversion Facility & Review of Hq Insp Procedure 88015 PNO-IV-96-066, on 961211,licensee Notified Nrc,Walnut Creek Field Ofc of Electrical Fire & Partial Loss of Site Power. Licensee Formed Incident Investigation Board to Review Event.State of Wa Will Be Informed1996-12-12012 December 1996 PNO-IV-96-066:on 961211,licensee Notified Nrc,Walnut Creek Field Ofc of Electrical Fire & Partial Loss of Site Power. Licensee Formed Incident Investigation Board to Review Event.State of Wa Will Be Informed ML20135D8221996-12-0505 December 1996 Insp Rept 70-1257/96-205 on 961104-07.No Violations Noted. Details Withheld ML20134K8161996-11-12012 November 1996 Insp Rept 70-1257/96-04 on 961021-25.Violations Noted.Major Areas Inspected:Emergency Preparedness,Fp,Followup on Licensee Events & Followup on Open Item from Previous Item ML20134K7921996-11-12012 November 1996 Notice of Violation from Insp on 961021-25.Violation Noted: as of 961022,licensee Had Not Calibrated Three Sets of direct-reading Dosimeters Maintained for Er Since 950918,for Two Sets & Since 950725,for the Third Set ML20149H4581994-11-10010 November 1994 Notice of Violation from Insp on 940926-30 & 1012-14. Violations Noted:Licensee Did Not Provide Training to Operators Relative to Modification or Evaluate Need to Revise Operating Procedures Prior to Restarting Sys ML20149H4771994-11-0202 November 1994 Insp Rept 70-1257/94-06 on 940926-30 & 1012-14.Violations Noted.Major Areas Inspected:Review Circumstances Re 940918 Event,Involving Spill of Approx 41 Kg of Low Enriched U Dioxide Power ML20058H9321993-11-22022 November 1993 Insp Rept 70-1257/93-12 on 931101-05.No Violations Noted. Major Areas Inspected:Fire Protection & Followup on Items of Noncompliance,Inspector Followup Items & NRC Info Notices ML20058D4261993-10-17017 October 1993 Insp Rept 70-1257/93-11 on 930908 & 0927-1001.No Violations or Deviations Noted.Major Areas Inspected:Criticality Safety,Operations & Followup on Open Items ML20057C5041993-08-26026 August 1993 Insp Rept 70-1257/93-10 on 930812.No Violations Noted.Major Areas Inspected:Announced Insp to Obtain Info on Licensee Employee Concerns Program ML20046D3401993-08-12012 August 1993 Partially Withheld Insp Rept 70-1257/93-201 on 930712-16. Details Withheld (Ref 10CFR2.790.) ML20056E4111993-08-0808 August 1993 Insp Rept 70-1257/93-09 on 930726-30.Violations Noted But Not Cited.Major Areas Inspected:Maint/Surveillance Testing, Radiation Protection,Criticality Safety/Operations Review, Environ/Waste Mgt & Followup on Open Items ML20056E9041993-08-0404 August 1993 Insp Rept 70-1257/93-08 on 930628-0702.No Violations Noted. Major Areas Inspected:Review Licensee Emergency Preparedness Program & Followup on Open Items 1999-08-25
[Table view] |
Text
-
y U. S. NUCLEAR REGULATORY COMMISSION REGION V
,p RehortNo.7C-1257/89-02 5
License.No.'SNM-1227 7
Priority:
O Category: III' Safeguards Group:
I Lic'ensee: Advanced Nuclear. Fuels, Inc.
2101 Horn Rapids' Road Richland, Washington 99352 Facility Name:.Richland Facility i
Inspe': tion at:
Richland, Washington Inspection Conducted:
April 17-21, 1989 Inspector:
2-f B. L. Brock, Fuel Facilities Inspector, Date Signed Approved by:
f/FM R. F. Fish, Chief, Emergency Preparedness D' ate Signed Section Summary:
Areas Inspected:
A routine unannounced inspection'was conducted of follow-up actions on open items, management organization, training and retraining, criticality safety, operations review, and radiation protection.
During this inspection, Inspection Procedures 92701, 88095, 88010, 88015, 88020, and 83822 were covered.
Results:
The licensee's response to the suggestion in the previous inspection report (70-1257/88-10) that additional attention was needed in the area of radiation protection was sufficiently responsive.
The improved performance will continue to receive attention.
1 No violations were identified in the six areas inspected.
l 8905310283ho 57 I -.
PDR ADOCK pg l
C
[
e
l 1
j l
DETAILS l
o 1.
Persons Contacted j
l A.
Advanced Nut' ear Fuels
- R. G. Frain, n% nager, Richland Operations
- T. W. Patten, Munager, Plant Operations
- R. H. Purcell, Manager, Safety and Security
- H. L. Caudell, Manager, Process and Equipment Engineering l
- T. C. Probasco, Supervisor, Radiological and Industrial Safety
- C. W. Malody, Manager, Corporate Licensing
E. Pieper, Specialist, Health Physics L. D. Gerrald, Criticality Safety Specialist S. R. Lockhaven, Specialist, Industrial Hygiene i
J. Edgar, Staff Engineer, Safeguards
- E.-L. Foster, Radiological' Safety Specialist G. V. Mulligan, Supervisor, Shipping L. D. Weaver, Shi"t Supervisor Conversion L. Stephens, Shift Supervisor, Conversion E. A. Johnson, Security Guard K. DeWeber, Security Gnard
- Denotes those attending the exit interview.
2.
Follow-up of Licensee Action on Open Items (92701)
A.
The following items are considered to be closed.
86-03-02 This inspector identified item involved the need to appropriately follow-up and document the timely cleanup of contamination levels exceeding the limits in the Part 1, f
License Conditions.
The licensee reinstituted use of the Health Physics Technicians logbook for notifying each subsequent shift of items requiring follow-up.
The need for diligence in-the use of the HPT logbook was emphasized to the HPTs.
The inspectors' examination of the HPT logbook confirmed that it was in routine use.
This item is therefore closed, 86-08-01 The ?icensee's Radiological; Safety Specialist is
. modifying the training records to include a completed Radiological Safety Training Record form, a copy of the test given for +he training, a distribution of the test results, the notes used in the training sessions, and the list of the persons attending the specific training courses-The inspector's review of the training records noted additionally the inclusion of the viewgraphs prepared from references, the course outline, and the document approving the proposed course subjects (signed by the Specialist, Health Physics, the Supervisor, Radiological and Industrial Safety, and the Specialist,
.},
4.
'd
~ '
.'D 3
L k
l' M
'.9 j
+
% j 2
7
- 2 x
,s.s
. Further, the Fuel Performance Group Industrial. Safety).
f (including one of the managers) was included in the recently completed Radiation Safety Training course.
This closes this item.
88-04-03 The licensee has implemented appropriate documentation listing all areas where contamination has temporarily been covered.
The documentation also includes a chronology of such areas (dating back to 1976), backup surveys, and sketches of the areas.
The licensee's response adequately addresses this item.
This item is considered closed.
88-10-03 The licensee revised the applicable procedure to require use of full face respiratory protection at half the airborne level previously required. Additionally, the user must turn in the respiratnr for cleaning after each shift rather than after a week of use as previously permitted, unless'a survey of the mask by an HPT at the end of the' shift found it free of contamination inside and out.
The licensee's response is appropriate.
This item is closed.
B.
The following items remain open.
88-02-05 The licensee engaged a consultant to do the independent review of the Radiological Contingency Plan..The consultant was provided reference documents for use in the review.
The consultant pointed out some areas for additior.ai licensee attention.
The inspector requested and received a copy of the consultants resume.
It appeared that the consultant was a competent' individual with significant experience in the nuclear industry, however he did not appear to have directly applicable experience in the field of emergency preparedness.
The lack of directly applicable experience is of sufficient importance to warrant leaving this item open for further review by a regional emergency preparedness inspector.
88-10-01 This item which centered around an apparent misinterpretation of the development of an exposure history as, required by 10 CFR 20.102, has apparently been appropriately responded to by the licensee.
However, the different interpretation the licensee has of the requirement needs to be discussed in depth.
For this reason this item remains open pending clarification and resolution of the differing points of view.
y
- 88-10-02 This item centered on the licensee's missing the opportunity to reduce the exposure of personnel to levels which were as law as reasonably achievable (ALRA).
The
~
licensee _was following his procedure when he did not
- investigate uptakes unless the airborne concentrations exceeded 25% of 40 MPC hours.
The NRC inspector noted
3 that the licensee did not investigate bioassay results that were positive but were still less than the licensee's action level.in his applicable procedure.
The licensee is taking action at levels less than committed to in his.
license and has indicated improved formalization and documentation will be provided.
This item remains open pending review of these changes.
3.
Functional or Program Areas Inspected A.
Management-Organization and Controls (88005)
(1) Organizational Structure (a) A week before this inspection'the licensee issued an organizational announcement which indicated.that the organizational structure was being changed.
One change involved the corporate licensing manager who previously reported to the process and equipment engineering manager and now reports to the' safety, security and licensing i
manager.
It is noted that'the corporate licensing manager continues to be responsible for the health physics component <, the criticality safety component, and for safeguards.
Additionally, the radiological and industrial safety supervisor who previously' reported to the safety
~
and secur,ity operations manager now also reports to the safety, security and licensing manager.
The radiological and industrial safety supervisor is still responsible for the plant criticality safety engineer and the health physics technicians,.
This organizational' change apparently results in a reduction of the checks and balances in the area of radiological and criticality safety audits which relate to plant safety.
The auditors and the auditees in radiological and criticality safety previously reported to separate managers who reported to a'vice president.
Under the new organizational ~ structure the auditor and the auditee report to the same manager one step below the vice president level.
There is no evidence that the auditing of the operations group has been compromised.
The manager of safety and security operations retired and was replaced by the senior operations analyst whose rer, possibilities iricluded internal audits for the operations group.
The manager of process and equipment engineering planned to retire on May 31, 1989.
The former manager of Richland Operations has been appointed vice president of production operations.
The manager of employee relations will become the manager of Richland Operations when a replacement for this position has been found.
__ =
4
('
(2) Safety Committee (a) The licensee. implemented'the annua 1 Criticality safety.
program appraisal that was added to ANF-30 (as recommended by the licensee's Criticality Safety Task Force).
The licensee's in-depth six weeks appraisal of his criticality safety program was beneficial.
The:results of.the
-appraisal (October 4 through November 15, 1988) identified twenty-six items needing attention.
Responsibility for each item was assigned and the status of the-items was
~
tracked by the safeguards staff engineer and reported.
monthly.
Twenty-five of the items have been corrected.
They ranged from correcting document inconsistencies, removing ambiguities, providing improved mounting for criticality limit cards, to emphasizing engineered safety features over administrative controls.
Only one item 4
, remains to be completed.
The remaining item involves y,
s assuring that all criticality safety analyses contain.
y com'plete references. This-last item is scheduled for
..N.
'4
],
completion by June 30, 1989.
1
~
)
(b) 'The. minutes of the Safety Committee, which met monthly as W
regbired, were reviewed by the NRC inspector.
The minutes.
s reflected the results of the internal. audits.
The status
,i s
s
=of the corrective action taken on identified items was also reported.
The results of the radiological safety
?
w T',
program were also tracked as well as the status of open-
~
s
' items identified by NRC inspectors.
e g
(3) Internal Review and Audit 1,
(a) In the previous inspection report, the licensee's ALARA C
report was described as appearing to fall short of an in-depth evaluation of the. licensee's radiation safety l
program.
The current inspection found that the licensee's reference materials, experiences, and knowledge.. relative-to the radiological and chemical hazards of uranium in the various forms processed was not provided to the NRC inspector throuyh some miscommunication.
Additionally, l'
the licensee's progress in completing the, installation of special equipment in a newly constructed building designed to house the Fuel Performance Group (which receives tools l
subject to hot particle contamination) was not discussed.
i.
The equipment and controls in place in the building designed for this work appear to be appropriate.
The communication breakdown precluded reaching a conclusion other than that expressed in this section of the previous report, specifically that the ALARA Committee's effort appeared to fall short of an indepth evaluation of the L
radiation safety program.
It appears now, however, that the ALARA Committee's report was reasonable.
Performance in this program area warrants continued attention with regard to the adequacy of the maintenance of an adequate program of l
i
s
.f t5)
, w 1
.g fs, V
i
- checks:and balances-in'the, organizational structure changes.' - No.
violations weee identified.
g.,
' B.
Traininb/kek.raininh(88010)
I t!
ju
+
~
(1) - The ;11censee's'Radiolbgicalt Safety" Specialist (RSS) subinitted-
~
the proposed Ra'diological _Safetypaining course lesson plan to' the. Specialist,5 Health Physics, and the! Supervisor, Radiological and Industrial Safety.for review and approval.
The approved lesson: planswas then used.to train (and retrain)~'
380 personi, in several trainingTsess"ns completed February 21',-
1989.
The RSS similarly prepared;a 1esson plan covering-Respiratory Protection Training and after its-approval by the1 same persons plus the Industrial Hygiene Specialist, conducted the' training.
The course was completed by 205 persons by February 22, 1989. 'The' records'for the courses included copies-
'of the concurrence of'the course' contents, the course outline,
~the view graphs used, copies from reference documents, the test
- results, the dispersion of the test results, and.the list of.
attendees.
(2) The licensee was preparing for a meeting;at which hot particles would be discussed.
A notice had been distributed that included as attachments the American Nuclear-Insurers Hot Particle Guidance and a portion of.a course that' addressed
' Automated Contamination Monitoring for Hot Particles.._The distribution preceded a meeting scheduled for May 3, 1989 at which Hot Particles would be discussed.
The licensee's performance in this area is improved.
The-effectiveness.of the changes will be' reviewed in subsequent.
' inspections.
It appears.the licensee is capable of meeting its safety objectives.
No violations were identified.
C.
Criticality Safety (88015)
(1) Facility Changes and Modifications The licensee's relocation of the Gadolinium Scrap Recovery Process (GSRP), the Ash Leach Pilot Plant-(ALPP), and the Decontamination Facility (DF) in a separate building is planned for the year 1992.
(2) Nuclear Criticality Safety Analysis The central region of the Radioactive Materials Warehouse was reconfigure for storage of various process materials containing special. nuclear material-(SNM) based on a criticality safety analysis of the various storage arrays performed by the Criticality Safety Specialist.
The criticality safety analysis was conservatively modeled for each storage array.
The second party r,eview was provided by the Specialist, Health Phydics and attested to by signature. The Criticality Safety Specifications.were prepared by the
[
)
se
~ ^
6.
Industrial Hygiene Specialist based on the limits and controls derived from the Criticality Safety Analysis.
(3) SNM Containers The licensee's modification of the CE-250 did not include the changes made,by Combustion Engineering.
The licensee's modifications consisted of adding a thicker inner ring that connected to an inner part to strerigthen the end and preclude the deformation and vermiculite leakage that resulted in test
-failure of the CE-250.
The container with the licensee's modification, now designated the ANF-250, passed the tests.
The licensee provided answers to some additional questions raised by NRC Headquarters after the test.
The licensee plans 1
to modify about'600 containers of this type, which he uses only
'for. overseas shipments, after the Certificate-of-Compliance is
. awarded.
(4) Observations No poor' criticality safety practices were observed during the site tour.
,(5) Audits zThe licensee's criticality safety audits were conducted as required and were of sufficient scope and depth.
The recent six week appraisal of the criticality safety management systems by a team of six persons, discussed in Section 3.A.(2)(a),
apparently contributed to the improved findings in the subsequent routine criticality monthly and bimonthly audits.
This appraisal had been added to ANF-30, Chapter 3 as an annual requirement.
Problems previously encountered in this area appeared to result
'from a failure to follow procedures.
Thus this area will continue to receive close attention even though the recent internal appraisal resulted in program improvements.
Performance in this program area warrants further review.
No violations were identified by the NRC inspector.
D.
Operations Review (88020)
(1) Conduct of Operations The licensee's performance was observed in several operational l
areas around the site.
The areas toured, not all of which were in operation, included:
a)
UO2 Building (Vaporization Room, Conversion Area, Powder Preparation, Powder Storage, Pellet Pressing, Ceramic Area,. Pellet grinding, Pellet Storage, Powder Characterization Room, Rod Loading, and Bundle Assembly),
f
_________m__________
I..
7-b)
Engineering Laboratory Operations Building (Gadolinium Scrap Recovery. Plant (GSRP), Ash Recovery Plant (ARP),
Decontamination Facility, and Process Development Laboratory),
c)
Solid Waste Uranium Recovery (SWUR) Facility.
(Incinerator),
d)
Neutron Absorber Facility (NAF),
e)
- Lagoons, f)
Radioactive Materials Warehouse (RMW), (pellet box
~
loading, moderated storage, and storage of used HEPA filters),
g)
Zimmer Warehouse, (storage of zimmer rods to.be declad and storage of LUR and GSRP products),
h)
Barrel Storage Yard (recoverable uranium contaminated waste),
1)
Laundry Facility (temporarily moved to the Irradiated Tool and Equipment Building) 1)
Ammonia Recovery Facility (ARF) k)
Fuel Performance Building The operations observed appeare'd:to follow procedures.
The licensee indicated that the liner of Lagoon 4 is scheduled to be replaced in June of 1989.
The licensee stated that the planned installation of additional ion exchange columns had not yet occurred.
The related laboratory work has achieved about a factor of ten reduction (1 PPM to 0.1 PPM) of the uranium in the plant effluent to the sewer.
The licensee is continuing the effort to-further redu'ce the uranium concentration of the
~
waste strea'm because of, reconcentration of the uranium at the local sewage treatment plant.
'The' uranium releases to the.
sewer are less than the'NRC limits in 10 CFR Part 20.
The leach pit' leak l(reported as required) has not been repaired
~
as the pit is still full of' sand.
Further cleanup of the sand is necessary before it can be released to unrestricted use.
l The licensee is also evaluating disposal of the sand to a licensed radioactive waste disposal site, Removal of t.he sand is essential for instituting repair of the leach pit.
A new liner for the leach pit has already been. acquired and is stored onsite.
(2) Facility Modification Revicw and Examination l
(a) The licensee completed the building housing the Fuel Performance Group.
The associated Irradiated Tool and
8 Equipment Room appeared to be in full operation.
The room included a long cleaning glovebox that is used for cleaning the long tools (up to 19 feet long).
The glovebox contained a lazy susan and several hose sprays fed from a contained water tank where the cleaning solution is mixed.
Adjacent to the long glovebox is an ultrasonic cleaner-for small parts.
North of the glovebox is an intermediate size parts cleaning tub that uses a rotating basket and counter directed sprays.
A deep pit for parts assembly and testing was also at the north end of the room.
Adjacent to the testing' pit was a 42 position shielded storage bin for parts up to 20 feet long.
A 1000 gallon tank and evaporator is in the room for evaporating the accumulated cleaning liquids and retaininn the solids for packaging and shipment to a licensea radioactive waste dosposal site.
The personnel change room and airlock is at the northwest end of the room and contains a Personnel Contamination Monitor (PCM) that includes 15 proportional counters for a total body survey.
The southeast corner of the room will eventually house the machineshop.
The southwest portion of the room contains the airlock (and step-off area) where the equipment is received or shipped.
Survey instruments are available in each of the airlocks.
Additionally, a shielded cave is available in which to check wipes in the high background (1000 CPM) in this: facility.
A window on the west wall of the room facilitates observation of activities and equipment calibrations using electrical 4^ connectors that lead to the electronics shop on the cold A}; p.
E, side of the window.
Instructions at the personnel egress t
i point require notification of a Health Physics Technician 1
QT
, in the event contamination is detected.
The licensee has
.yy issued a new Personnel Contamination Report form, as part y\\;
fof the radiological safety record, which facilitates
[
^
recording the necessary information about an event in
[
whis.1 a hot particle is detected (see Section 3.E.(1)).
t l
(b) The licensee's laundry facility had been temporarily relocated to the Irradiated Tools and Equipment building that formerly housed the Fuel Performance Group.
The s
"(
f
_ permanent laundry quarters are being expanded to accommodate two industrial size washing machines.
Additionally, the laundry will change from an organic medium to an aqueous medium for laundering the protective clothing.
The modifications to the building were well underway and the laundry will likely be back in its former location and in full operation by the next inspection.
i l
9 l
I (3) Housekeeping i
(a) The yard south of the solvent storage building showed evidence of spilled oil, had an uncovered bucket of oil, and an uncovered bucket of what was identified as likely ethylene glycol.
The solvent storage building contained a three quarters full drip tray under one of the oil barrels stored on the. horizontal racks.
Oily rags were noted in the area.
(b) The containers of sand used in testing the CE-250 shipping i
containers were.in the Radioactive Materials Warehouse (RMW) without any indications.as to their contents.
Unlabe' led 55 gallon steel; drums and rectangular boxes f(apparently, standards for the'non-destructive assay system-used with the incinerator) stored in the south end of the RMW alsofraised 'uestions regarding their contents because q
, =of the. lack of labeling.
n t-(c) JThe ash leach room in the ELO basement also had an unlabeled container on the floorfthat apparently had been
~
removed from/the feed hopper or was about to be added to it.
If.the' container had recently been removed from the hopper then it would have been' prudent to put the labeled e lid back on the containeri correcting the label as necessary.
If the container was~to be added to the hopper then.it would have been prudent not to leave the container open and unattended during a period when the system was not in operation.'
(d) The line 2 conversion area had an overhead leak in the scrubber exhaust duct that dripped a solution that-left a salt deposit on the duct and on the lid of the vaporization chest.
The licensee's housekeeping appeared to be in need of additional attention.
(4) Fuel Handling and Storage The fuel rod operations observed during the tour involved only Non-Destructive Assay (NDA) of loaded. fuel rods.
The NDA system uses neutron interrogation and is set to detect the inclusion of pellets of the wrong enrichment.
l Performance in this program area in general appears to be adequate; however, housekeeping needs improvement.
No violations of criticality controls were observed in the facilities visited.
l l
l 1
-.-x.__-
e 10 l:
F.
Radiation Protection (83822) l (1) Radiation Protection Procedures The licensee instituted the use of a new form to generate a record of pertinent information for use in rvaluating the dose-that an area of the skin received from a hot particle.
The new form, Personnel Contamination Report form, was issued as part of.the radiological safety record and. facilitates recording the contamination level, location on the body (pictorially as well as by written description), the size of the area, instrumentation used, countrate before ar,d after decontamination, the circumstances involved, whether or not a hot particle was found, whether or not a bioassay is required,
< and the skin dose estimate.
The licensee" acknowledged that in addition to painting over contamination with a yellow coat of paint followed by a grey coat, another approach to identifying contamination was needed.
The different' approach involved the shredder in the portable trailer.
A piece of contaminated plywood flooring in the trailer didn't decontaminate well, therefor the situation was identified by a permanent wall sign that read " CAUTION, The subfloor of this unit is contaminated and must be surveyed and unconditionally released before the unit is removed from plant site".
(2)' Instruments and Equipment The inspector examined portable radiation detection instrumentation and air sampling equipment during facility tours.
All instruments were found to be in current calibration.
The 31 fire extinguishers checked during the site tour all bore tags indicating the fire extinguishers were being inspected monthly as required.
(3) Exposure Controls To preclude unrecorded exposures of ANF employees who travel to reactor sites and fi.id they've forgotten their dosimeters, consideration is being given to. issuing extra thermoluminescent dosimeters (TLDs) to their team leaders for issuance as needed.
This will facilitate controlling exposures within nationally recognized limits as well as ALARA.
(4) ALARA The adequacy of the performance of the HP staff was called into question during the previous inspection.
Improvements have 1
been noted in training and record keeping, however, this area will continue to receive additional attention until it is clear that the workload allows for routine job site control of operations and maintenance activities.
I o
7 y;
)9
- 11-
, i F
SJ IT The 11censee's performance inlthis area still needs; improvement but seemed capable of meeting its safety objectives.
No violations or-O deviations were identified however, additional attention rill be provided to this area.
.g 5.
Exit Interview I
At the conch:sion of the inspection the findings were discussed with the licensee's staff identified in Section~1.
The topics discussed included:
The areas inspected.
Open item status:
i Closed items 4_
Open items (old) 3_
Open items-(new) 0 j
Possible weakening of the checks and balances through the planned structural reorganization.
l Increased attention being given to finding cause of positive bioassay and in-vivo measurements.
The additional attention needed in housekeeping.
Expeditious correction of the items identified in the annual Criticality Safety program appraisal.
The need to identify root causes for problems encountered and identification of management's contribution to the problem, if any.
i Response to Notice of Violation (a) Noted protective clothing reuse practices.
(b) Noted license amendhient regarding protective clothing laundry release limits.
Apparent progress in recovering the uranium from the waste drums.
Progress made in preparing to recover uranium from the HEPA filters.
~
_ _ _ _ _a