MONTHYEARML20217F9551999-10-14014 October 1999 Application for Amends to Licenses DPR-77 & DPR-79,proposing Change to TS SRs & Bases to Incorporate ARC for Axial Primary Water Stress Corrosion Cracking at Dented Tube Support Plant Intersections ML20217E4211999-10-12012 October 1999 TS Change 99-15 to Licenses DPR-77 & DPR-79,providing Unisolation of Containment Penetrations Under Administrative Controls ML20211K1521999-08-30030 August 1999 TS Change 99-10 to Licenses DPR-77 & DPR-79,providing Clarification to Current TS Requirements for Containment Isolation Valves ML20211M7261999-08-30030 August 1999 TS Change 99-08,for Amends to Licenses DPR-77 & DPR-79 to Provide Alternative to Requirement of Actually Measuring Response times.Marked-up & Revised TS Pages,Encl ML20209B7661999-06-30030 June 1999 Application for Amends to Licenses DPR-77 & DPR-79,updating Current TS Requirements for RCS Leakage Detection & RCS Operational Leakage Specifications to Be Consistent with NUREG-1431 ML20196G4441999-06-24024 June 1999 Application for Amends to Licenses DPR-77 & DPR-79,to Revise TS to Be Consistent with Rev to ISTS Presently Submitted to NEI TSTF for Submittal as Rev to NUREG-1431 ML20196F2121999-06-24024 June 1999 Application for Amends to Licenses DPR-77 & DPR-79,to Change TS Allowing Use of Fully Qualified & Tested Spare Inverter in Place of Any of Eight Required Inverters ML20195E9661999-06-0707 June 1999 Application for Amend to License DPR-79,increasing Max Allowed Specific Activity of Primary Coolant from 0.35 Microcuries/Gram Dose Equivalent I-131 to 1.0 Microcuries/ Gram Dose Equivalent I-131 for Plant Cycle 10 (U2C10) Core ML20206E1551999-04-29029 April 1999 Application for Amends to Licenses DPR-77 & DPR-79, Consisting of TS Change 99-04, Auxiliary Feedwater Suction Pressure Low Surveillance Frequency Rev. Change Deletes Surveillance ML20206E1341999-04-29029 April 1999 Application for Amends to Licenses DPR-77 & DPR-79, Consisting of TS Change Request 99-03, Main Control Room Emergency Ventilation Sys Verses Radiation Monitors. Change Adds LCOs 3.3.3.1 & 3.7.7 & NUREG-1431 Changes ML20204H3991999-03-19019 March 1999 TS Change 99-01 to Licenses DPR-77 & DPR-79,relocating TS Associated with Electrical Equipment Protective Devices to Technical Requirements Manual ML20207D5941999-02-26026 February 1999 Application for Amend to Licenses DPR-77 & DPR-79,relocating TS 3.7.6, Flood Protection Plan & Associated Bases from TS to Plant TRM ML20207D6251999-02-26026 February 1999 Application for Amends to Licenses DPR-77 & DPR-79,revising TS to Provide for Consistency When Exiting Action Statements Associated with EDG Sets ML20199K5841999-01-15015 January 1999 Application for Amends to Licenses DPR-77 & DPR-79,adding New Action Statement to TS 3.1.3.2 That Would Eliminate Need to Enter TS 3.0.3 Whenever Two or More Individual RPIs Per Bank May Be Inoperable,While Maintaining Protection ML20206S0061999-01-15015 January 1999 TS Change 98-09 for Licenses DPR-77 & DPR-79,relocating TS 3.3.3.3, Seismic Instrumentation & Associated Bases from TS to Plant Technical Requirements Manual ML20195H6041998-11-16016 November 1998 Application for Amends to Licenses DPR-77 & DPR-79,revising EDG SRs by Adding Note to Allow SR to Be Performed in Modes 1,2,3 or 4 If Associated Components Are Already OOS for Testing or Maint & Removing SR Verifying Lockout Features ML20154H7201998-10-0808 October 1998 Supplemental Application for Amends to Licenses DPR-77 & DPR-79,changing TS to Add CRMP to Administrative Controls Section & Bases of TS ML20238F1051998-08-27027 August 1998 Application for Amend to License DPR-79,revising TS to Provide for Insertion of Limited Number of Lead Test Assemblies,Beginning W/Unit 2 Operating Cycle 10 Core ML20238F2981998-08-27027 August 1998 Revised Applications for Amends to Licenses DPR-77 & DPR-79, Replacing 72 H AOT of TS 3.8.1.1,Action b,w/7 Day AOT Requirement for Inoperability of One EDG or One Train of Edg.Response to RAI Included in Encl ML20249C6321998-06-26026 June 1998 Application for Amends to Licenses DPR-77 & DPR-79,lowering Specific Activity of Primary Coolant from 1.0 Uci/G Dose Equivalent I-131 to 0.35 Uci/G Dose Equivalent I-131,as Provided in GL 95-05 ML20248E9841998-05-28028 May 1998 Suppl TS Change 95-19 to Licenses DPR-77 & DPR-79,replacing Direct Ref to Nuclear QA Plan in TS Section 6.3.1,facility Staff Qualification,W/Actual Requirements Stated in TVA-NQA-PLN89-A ML20217N3411998-04-30030 April 1998 Application for Amends to Licenses DPR-77 & DPR-79,modifying TS Surveillance Requirement 4.4.3.2.1.b to Change Mode Requirement to Allow PORV Stroke Testing in Modes 3,4 & 5 W/Steam Bubble in Pressurizer Rather than Only in Mode 4 ML20203J1511998-02-25025 February 1998 Application for Amends to Licenses DPR-77 & DPR-79 to Change TS for Units 1 & 2,revising EDG Surveillance Requirements ML20202J6601998-02-13013 February 1998 Application for Amends to Licenses DPR-77 & DPR-79, Incorporating MSIV Requirements to Be Consistent W/Std TS (NUREG-1431) ML20202J7101998-02-13013 February 1998 Application for Amends to Licenses DPR-77 & DPR-79,adding New LCO That Addresses Requirements for Main Feedwater Isolation,Regulating & Bypass Valves ML20202J7421998-02-13013 February 1998 TS Change 97-04 to Application for Amends to Licenses DPR-77 & DPR-79,relocating Snubber Requirements from Section 3.7.9 of TS to Plant Technical Requirements Manual ML20198T4211998-01-21021 January 1998 Suppl TS Change 95-19 to Licenses DPR-77 & DPR-79,revising Title for President,Tva Nuclear & Chief Nuclear Officer to Generic Title of Chief Nuclear Officer ML20199K4441997-11-21021 November 1997 Application for Amend to License DPR-55,adding one-time Allowance Through Operating Cycle 9 to Surveillance Requirement 4.4.3.2.1.b to Perform Stroke Testing of PORVs in Mode 5 Rather than Mode 4,as Currently Required ML20211A3091997-09-17017 September 1997 TS Change 97-02 to Licenses DPR-77 & DPR-79,revising Pressure Differential Surveillance Requirements for Containment Spray Pumps ML20137C8271997-03-19019 March 1997 Revised TS Change 96-01 to Licenses DPR-77 & DPR-79,revising Appropriate Specifications,Surveillances & Bases to Allow for Conversion from Westinghouse Fuel to Framatome Cogema Fuel ML20136J0251997-03-13013 March 1997 Application for Amends to Licenses DPR-77 & DPR-79,revising Allowed Enrichment of Fuel in TS Section 5.6.1.2 for New Fuel Pit Storage Racks from 4.5 to 5.0 Weight % U-235 ML20129D2561996-10-18018 October 1996 Application for Amends to Licenses DPR-77 & DPR-79,removing Existing Footnotes That Limit Application of Apc for Plant SG Tubes to Cycle 8 Operation for Both Units ML20129G7111996-09-26026 September 1996 Application for Amends to Licenses DPR-77 & DPR-79,revising Fire Protection License Conditions & Relocation of Fire Protection Tech Spec ML20113G2421996-09-20020 September 1996 Application for Amends to Licenses DPR-77 & DPR-79, Clarifying Work Shift Durations for Overtime Limits ML20117J3341996-08-28028 August 1996 Application for Amends to Licenses DPR-77 & DPR-79, Revising Psv & MSSV Setpoint Tolerance from Plus or Minus 1% to Plus or Minus 3% ML20117D0921996-08-22022 August 1996 Application for Amends to Licenses DPR-77 & 79 Changing Tss of Sqb Units 1 & 2 by Deleting Table 4.8-1, DG Reliability & Revising Sectio 3.8.1 to Allow a Once Per 18 Month 7 Day AOT for EDGs ML20117D3271996-08-21021 August 1996 TS Change 96-06 to Licenses DPR-77 & DPR-79,removing Surveillance Requirement 4.8.1.1.1.b to Verify Ability to Transfer Unit Power Supply from Unit Generator Supported Circuit to Preferred Power Circuit ML20117D2931996-08-21021 August 1996 TS Change 96-03 to Licenses DPR-77 & DPR-79,revising TS 3.7.1.3, Condensate Storage Tank, to Include New Mode of Applicability to Read Mode 4 When SG Relied Upon for Heat Removal ML20112H0361996-06-0707 June 1996 Application for Amends to Licenses DPR-77 & DPR-79,revising Section 6, Administrative Controls, to Be More Closely Aligned W/Requirements of STSs ML20101N6981996-04-0404 April 1996 TS Change 96-01 to Licenses DPR-77 & DPR-79,allowing Use of Nuclear Fuel Provided by Framatome Cogema Fuels (Fcf). Proprietary & Nonproprietary Versions of Fcf TR Supporting TS Change 96-01 Encl.Proprietary Version of TR Withheld ML20096B3671996-01-0404 January 1996 Application for Amends to Licenses DPR-77 & DPR-79,revising TS Change 95-22,extending Radiation Monitoring Instrumentation Surveillance Period Per GL 93-05 ML20095F0271995-12-12012 December 1995 Application for Amend to License DPR-79,consisting of TS Change 95-23 Revising TS SRs & Bases to Incorporate Alternate S/G Tube Plugging Criteria at Tube Support Plate Intersections,Per GL 95-05 ML20095D5731995-12-0808 December 1995 Application for Amends to Licenses DPR-77 & DPR-79, Consisting of TS Change 95-20,extending Containment Spray & RHR Sys Nozzles Testing Period from 5 to 10 Yrs in Accordance W/Gl 93-05 ML20095D5431995-12-0808 December 1995 Application for Amend to Licenses DPR-77 & DPR-79,consisting of TS Change 93-09,revising Setpoints & Time Delays for AFW loss-of-power & 6.9 Kv Shutdown Board loss-of-voltage & degraded-voltage Instrumentation ML20095D5811995-12-0808 December 1995 Application for Amend to Licenses DPR-77 & DPR-79,revising TSs to Implement Recent Rule Change to 10CFR50,App J ML20092E0191995-09-11011 September 1995 Application for Amend to License DPR-79,consisting of TS Change Request 95-13,rev 1 Re Extension of Response Time Surveillance Requirements for Unit Two Cycle 7 ML20092E0351995-09-0808 September 1995 Application for Amends to Licenses DPR-77 & DPR-79,revising Section 3/4.7.8 to Clarify Intent of Vacuum Relief Flow During TS Required Testing of Auxiliary Bldg Gas Treatment Sys ML20092E2741995-09-0707 September 1995 Revised TS Change 95-15 for Amend to License DPR-77,revising TS Surveillance Requirements & Bases to Incorporate Alternate S/G Tube Plugging Criteria at Tube Support Plate Intersections,Per GL 95-05 ML20091K4241995-08-21021 August 1995 Proposed TS Change 95-21 to Licenses DPR-77 & DPR-79, Revising TS LCO 3.7.5.c to Allow for Increase in Ultimate Heat Sink Temp to 87 F Until 950930 ML20087D3751995-08-0707 August 1995 Application for Amends to Licenses DPR-77 & DPR-79,revising Time Constants for Overtemp Delta Temp & Overpower Delta Temp Equations 1999-08-30
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20217F9551999-10-14014 October 1999 Application for Amends to Licenses DPR-77 & DPR-79,proposing Change to TS SRs & Bases to Incorporate ARC for Axial Primary Water Stress Corrosion Cracking at Dented Tube Support Plant Intersections ML20217E4211999-10-12012 October 1999 TS Change 99-15 to Licenses DPR-77 & DPR-79,providing Unisolation of Containment Penetrations Under Administrative Controls ML20212F4601999-09-23023 September 1999 Amends 246 & 237 to Licenses DPR-77 & DPR-79,respectively, Approving Request to Revise TSs to Allow Use of Fully Qualified & Tested Spare Inverter in Place of Any of Eight Required Inverters ML20211K1521999-08-30030 August 1999 TS Change 99-10 to Licenses DPR-77 & DPR-79,providing Clarification to Current TS Requirements for Containment Isolation Valves ML20211M7261999-08-30030 August 1999 TS Change 99-08,for Amends to Licenses DPR-77 & DPR-79 to Provide Alternative to Requirement of Actually Measuring Response times.Marked-up & Revised TS Pages,Encl ML20209B7661999-06-30030 June 1999 Application for Amends to Licenses DPR-77 & DPR-79,updating Current TS Requirements for RCS Leakage Detection & RCS Operational Leakage Specifications to Be Consistent with NUREG-1431 ML20196G4441999-06-24024 June 1999 Application for Amends to Licenses DPR-77 & DPR-79,to Revise TS to Be Consistent with Rev to ISTS Presently Submitted to NEI TSTF for Submittal as Rev to NUREG-1431 ML20196F2121999-06-24024 June 1999 Application for Amends to Licenses DPR-77 & DPR-79,to Change TS Allowing Use of Fully Qualified & Tested Spare Inverter in Place of Any of Eight Required Inverters ML20195E9661999-06-0707 June 1999 Application for Amend to License DPR-79,increasing Max Allowed Specific Activity of Primary Coolant from 0.35 Microcuries/Gram Dose Equivalent I-131 to 1.0 Microcuries/ Gram Dose Equivalent I-131 for Plant Cycle 10 (U2C10) Core ML20207A5781999-05-20020 May 1999 Errata to Amend 163 to OL DPR-79 on 931126.SR 4.1.1.1.1.d Was Inadvertently Omitted from Pp 3/4 1-1 of Unit 2 TS ML20206E1341999-04-29029 April 1999 Application for Amends to Licenses DPR-77 & DPR-79, Consisting of TS Change Request 99-03, Main Control Room Emergency Ventilation Sys Verses Radiation Monitors. Change Adds LCOs 3.3.3.1 & 3.7.7 & NUREG-1431 Changes ML20206E1551999-04-29029 April 1999 Application for Amends to Licenses DPR-77 & DPR-79, Consisting of TS Change 99-04, Auxiliary Feedwater Suction Pressure Low Surveillance Frequency Rev. Change Deletes Surveillance ML20204H3991999-03-19019 March 1999 TS Change 99-01 to Licenses DPR-77 & DPR-79,relocating TS Associated with Electrical Equipment Protective Devices to Technical Requirements Manual ML20207D5941999-02-26026 February 1999 Application for Amend to Licenses DPR-77 & DPR-79,relocating TS 3.7.6, Flood Protection Plan & Associated Bases from TS to Plant TRM ML20207D6251999-02-26026 February 1999 Application for Amends to Licenses DPR-77 & DPR-79,revising TS to Provide for Consistency When Exiting Action Statements Associated with EDG Sets ML20206S0061999-01-15015 January 1999 TS Change 98-09 for Licenses DPR-77 & DPR-79,relocating TS 3.3.3.3, Seismic Instrumentation & Associated Bases from TS to Plant Technical Requirements Manual ML20199K5841999-01-15015 January 1999 Application for Amends to Licenses DPR-77 & DPR-79,adding New Action Statement to TS 3.1.3.2 That Would Eliminate Need to Enter TS 3.0.3 Whenever Two or More Individual RPIs Per Bank May Be Inoperable,While Maintaining Protection ML20195H6041998-11-16016 November 1998 Application for Amends to Licenses DPR-77 & DPR-79,revising EDG SRs by Adding Note to Allow SR to Be Performed in Modes 1,2,3 or 4 If Associated Components Are Already OOS for Testing or Maint & Removing SR Verifying Lockout Features ML20154H7201998-10-0808 October 1998 Supplemental Application for Amends to Licenses DPR-77 & DPR-79,changing TS to Add CRMP to Administrative Controls Section & Bases of TS ML20238F1051998-08-27027 August 1998 Application for Amend to License DPR-79,revising TS to Provide for Insertion of Limited Number of Lead Test Assemblies,Beginning W/Unit 2 Operating Cycle 10 Core ML20238F2981998-08-27027 August 1998 Revised Applications for Amends to Licenses DPR-77 & DPR-79, Replacing 72 H AOT of TS 3.8.1.1,Action b,w/7 Day AOT Requirement for Inoperability of One EDG or One Train of Edg.Response to RAI Included in Encl ML20249C6321998-06-26026 June 1998 Application for Amends to Licenses DPR-77 & DPR-79,lowering Specific Activity of Primary Coolant from 1.0 Uci/G Dose Equivalent I-131 to 0.35 Uci/G Dose Equivalent I-131,as Provided in GL 95-05 ML20248E9841998-05-28028 May 1998 Suppl TS Change 95-19 to Licenses DPR-77 & DPR-79,replacing Direct Ref to Nuclear QA Plan in TS Section 6.3.1,facility Staff Qualification,W/Actual Requirements Stated in TVA-NQA-PLN89-A ML20217N3411998-04-30030 April 1998 Application for Amends to Licenses DPR-77 & DPR-79,modifying TS Surveillance Requirement 4.4.3.2.1.b to Change Mode Requirement to Allow PORV Stroke Testing in Modes 3,4 & 5 W/Steam Bubble in Pressurizer Rather than Only in Mode 4 ML20203J1511998-02-25025 February 1998 Application for Amends to Licenses DPR-77 & DPR-79 to Change TS for Units 1 & 2,revising EDG Surveillance Requirements ML20202J6601998-02-13013 February 1998 Application for Amends to Licenses DPR-77 & DPR-79, Incorporating MSIV Requirements to Be Consistent W/Std TS (NUREG-1431) ML20202J7421998-02-13013 February 1998 TS Change 97-04 to Application for Amends to Licenses DPR-77 & DPR-79,relocating Snubber Requirements from Section 3.7.9 of TS to Plant Technical Requirements Manual ML20202J7101998-02-13013 February 1998 Application for Amends to Licenses DPR-77 & DPR-79,adding New LCO That Addresses Requirements for Main Feedwater Isolation,Regulating & Bypass Valves ML20198T4211998-01-21021 January 1998 Suppl TS Change 95-19 to Licenses DPR-77 & DPR-79,revising Title for President,Tva Nuclear & Chief Nuclear Officer to Generic Title of Chief Nuclear Officer ML20199K4441997-11-21021 November 1997 Application for Amend to License DPR-55,adding one-time Allowance Through Operating Cycle 9 to Surveillance Requirement 4.4.3.2.1.b to Perform Stroke Testing of PORVs in Mode 5 Rather than Mode 4,as Currently Required ML20211A3091997-09-17017 September 1997 TS Change 97-02 to Licenses DPR-77 & DPR-79,revising Pressure Differential Surveillance Requirements for Containment Spray Pumps ML20137C8271997-03-19019 March 1997 Revised TS Change 96-01 to Licenses DPR-77 & DPR-79,revising Appropriate Specifications,Surveillances & Bases to Allow for Conversion from Westinghouse Fuel to Framatome Cogema Fuel ML20136J0251997-03-13013 March 1997 Application for Amends to Licenses DPR-77 & DPR-79,revising Allowed Enrichment of Fuel in TS Section 5.6.1.2 for New Fuel Pit Storage Racks from 4.5 to 5.0 Weight % U-235 IA-97-261, Amend 220 to License DPR-77,authorizing Operation at Reactor Core Power Levels Not in Excess of 3,411 Megawatts Thermal1997-03-0404 March 1997 Amend 220 to License DPR-77,authorizing Operation at Reactor Core Power Levels Not in Excess of 3,411 Megawatts Thermal ML20211K5631997-03-0404 March 1997 Amend 220 to License DPR-77,authorizing Operation at Reactor Core Power Levels Not in Excess of 3,411 Megawatts Thermal ML20129D2561996-10-18018 October 1996 Application for Amends to Licenses DPR-77 & DPR-79,removing Existing Footnotes That Limit Application of Apc for Plant SG Tubes to Cycle 8 Operation for Both Units ML20129G7111996-09-26026 September 1996 Application for Amends to Licenses DPR-77 & DPR-79,revising Fire Protection License Conditions & Relocation of Fire Protection Tech Spec ML20113G2421996-09-20020 September 1996 Application for Amends to Licenses DPR-77 & DPR-79, Clarifying Work Shift Durations for Overtime Limits ML20117J3341996-08-28028 August 1996 Application for Amends to Licenses DPR-77 & DPR-79, Revising Psv & MSSV Setpoint Tolerance from Plus or Minus 1% to Plus or Minus 3% ML20117D0921996-08-22022 August 1996 Application for Amends to Licenses DPR-77 & 79 Changing Tss of Sqb Units 1 & 2 by Deleting Table 4.8-1, DG Reliability & Revising Sectio 3.8.1 to Allow a Once Per 18 Month 7 Day AOT for EDGs ML20117D2931996-08-21021 August 1996 TS Change 96-03 to Licenses DPR-77 & DPR-79,revising TS 3.7.1.3, Condensate Storage Tank, to Include New Mode of Applicability to Read Mode 4 When SG Relied Upon for Heat Removal ML20117D3271996-08-21021 August 1996 TS Change 96-06 to Licenses DPR-77 & DPR-79,removing Surveillance Requirement 4.8.1.1.1.b to Verify Ability to Transfer Unit Power Supply from Unit Generator Supported Circuit to Preferred Power Circuit ML20112H0361996-06-0707 June 1996 Application for Amends to Licenses DPR-77 & DPR-79,revising Section 6, Administrative Controls, to Be More Closely Aligned W/Requirements of STSs ML20101N6981996-04-0404 April 1996 TS Change 96-01 to Licenses DPR-77 & DPR-79,allowing Use of Nuclear Fuel Provided by Framatome Cogema Fuels (Fcf). Proprietary & Nonproprietary Versions of Fcf TR Supporting TS Change 96-01 Encl.Proprietary Version of TR Withheld ML20096B3671996-01-0404 January 1996 Application for Amends to Licenses DPR-77 & DPR-79,revising TS Change 95-22,extending Radiation Monitoring Instrumentation Surveillance Period Per GL 93-05 ML20095F0271995-12-12012 December 1995 Application for Amend to License DPR-79,consisting of TS Change 95-23 Revising TS SRs & Bases to Incorporate Alternate S/G Tube Plugging Criteria at Tube Support Plate Intersections,Per GL 95-05 ML20095D5431995-12-0808 December 1995 Application for Amend to Licenses DPR-77 & DPR-79,consisting of TS Change 93-09,revising Setpoints & Time Delays for AFW loss-of-power & 6.9 Kv Shutdown Board loss-of-voltage & degraded-voltage Instrumentation ML20095D5731995-12-0808 December 1995 Application for Amends to Licenses DPR-77 & DPR-79, Consisting of TS Change 95-20,extending Containment Spray & RHR Sys Nozzles Testing Period from 5 to 10 Yrs in Accordance W/Gl 93-05 ML20095D5811995-12-0808 December 1995 Application for Amend to Licenses DPR-77 & DPR-79,revising TSs to Implement Recent Rule Change to 10CFR50,App J ML20092E0191995-09-11011 September 1995 Application for Amend to License DPR-79,consisting of TS Change Request 95-13,rev 1 Re Extension of Response Time Surveillance Requirements for Unit Two Cycle 7 1999-09-23
[Table view] |
Text
. - - _ _ _ _ _ _ _ _ _ _ - - - _ - _ _ _ _ - _ - .
'.) '
Tennessee Valley Authority, Post Offee Box 2000. SoddpDaisy Tennessee 37379-2000 February 13, 1998 TVA-SQN-TS-97-07 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:
In the Mat rer of ) Docket Nos. 50-327 Tennessee Valley Authority ) 50-328 SEQUO/AH NUCLEAR PLANT (SQN) - UNITS 1 AND 2 - TECHNICAL SPECIFICATION (TS) CHANGE NO 97-07, " REVISION OF NAIN STEAM ISOLATION VALVE REQUIREMENTS" In accordance with the provisions of 10 CFR 50.4 and 50.90, TVA is submitting a request for an amendment to SON's Licenses DPR-77 and 79 to change the TSs for Units 1 and 2.
The proposed change will revise the TS requirements for main steam isolation valves (MSIVs). TVA will incorporate MSIV requirements consistent with the Standard TS (NUREG-1431) in the proposed revision. TVA also adds testing requirements for the MSIVs that ensure the valves close on an actual or simulated automatic actuation signal. NRC approval of the proposed TS change request will complete one of two TS
-amendments identified by the Generic Letter 96-01 reviews.
TVA has determined that there are no significant hazards considerations associated with the proposed change and that the change is exempt from environmental review pursuant to s the provisions of 10 CFR 51.22 (c) (9) . The SON Plant Operations Review Committee and the SON Nuclear Safety Review Board have reviewed this proposed change and determined that operation of SON Units 1 and 2, in accordance with the t 9802230192 PDR ADOCK 0500 900213 7
fv ,
llll{
l{ l ll
- - _o
.g U.S. Nuclear Regulatory Commission Page 2
. . February 13, 1998 proposed change, will not endanger the health and safety of the public. Additionally, in accordance with 10 CFR
- 50. 91 (b) (1) , TVA is sending a copy of this letter to the Tennessee State Department of Public Health.
Enclooure 1 to this letter provides the description and evalustion of the proposed change. This includes TVA's determination that the proposed change does not involve a significant hazards. consideration, and is exempt from environmental review. Enclosure 2 contains copies of the appropriate TS pages from Units 1 and 2 marked-up to show the t
proposed change. Enclosure 3 forwards the revised TS pages for Units 1 and.i, which incorporate the proposed change.
TVA requests that the revised TS be made effective within 45 days of NRC approval. If you have any questions about-this change, please telephone me at (423) 843-7170 or J. D. Smith at (423) 643-6672.
Sincerely, f-i
,,s' e Salas Licensing and Industry Affairs Manager a
Subscribed;a,9d sworn t . fore me-o this _ /0 U day of . ny144
$%m Notar9'Fublic 7X J/dmL,.s
/ /
My Commission Expires h/
Enclosures. ,
cc: See page 3 1
.. . ....,_../
U.S. Nuclear Regulatory Commission l Page 3
, February 13, 1998 cc (Enclosures):
Mr. R. W. Hernen, Project Manager l
Nuclear Regulatory Commission one White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Michael H. Mobley, Director (w/o Enclosures)
Division of Radiological Health Third Floor L&C Annex 401 Church Street Nashville, Tennessee 37243-1532 I
NRC Resident Sequoyah Nuclear Plant 2600 Igoa Ferry Road Soddy-Daisy, Tennessee 37379-3624 Regional Administrator U.S. Nuclear Regulatory Commission Region II Atlanta Federal Center 61 Forsyth St., SW,-Suite 23785 Atlanta, Georgia 30303-3415 l
9 ENCLOSURE 1 TENNESSEE VALLEY AUTHORITY SEQUOYAM NUCLEAR PLANT (SQN)
ONITS 1 ano 2 DOCKET NOS 327 AND 328 PROPOSED TECHNICAL SPNCIFICATION (TS) CHANGE TS 97-07 DESCRIPTION AND EVALUA? ION OF THE PROPOSED CHANGE I. DESCRIPTION OF THE PROPOSED CEAMUE TVA proposes a change to the cur- -
requirements for the main steam isolation valve that will provide consistency with the sta- o i UREG-1431). TVA will change the following itr
- 1. Revision of the Limit...g Condition for Operation (LCO) statement to require four MSIVs instead of each MSIV;
- 2. Removal of a option to close the MSIV for the Mode 1 4
actien;
. 3. Revision of the action for Mode 1 to cnly require
{ shutdown to Mode 2;
- 4. Revision of the Modes 2 and 3 actions to allow one or more MSIVs to be inoperablei
- 5. Revision of the "a" item of the Modes 2 and 3 actions to provide the option to return the MSIV to operable status and addition of the time interval required for this item;
- 6. Addition of a new item to the actions for Modes 2 and 3 tia* will require the verification that the inoperable MSIV is closed once every seven days;
. Addition of a new item to the actions for Modes 2 and 3 that allows separate entry into the actions for each ME 4'; and
- 8. Ajdition of a new surveillance to verify closurr. of each MSIV on an actual or simulated automatic actuation signal once every 18 months.
3 El-1
_a ~
0 4 II. REASON FOR THE PROPOSED CHANGE '
.TVA proposes the above described changes tv provide consistency with NUREG-1431 and to provide e. surveillance requirement that will ensure the main steam isolation function is adequately tested. Specific reasons for each of the above described changes are provided as follows:
- 1. Revision of the LCO statement from "each" to "four" provides consistency with NUREG-1431 and other specifications and clarifies the LCO scope. This i
change provides consistency with NUREG-1431,
- 2. In Mode 1, the closure of an MSIV is not practical l
because of the adverse effect on unit operation.
Therefore, the action provision to close the valve has ,
been eliminated. This Tge provides consistency with NUREG-1431.
- 3. When an MSIV can not be returned to cperable status in
! Mode 1, a shutdown ,elow Mode 2 is not necessary.
I Act ons for Mode 2 irovide other options for continued
! operation without requiring a shutdown to lower modes.
I This change provides consistency with NUREG-1431. -
- 4. The provision to allow one or more MSIVs to be inoperable in Modes 2 and 3 provide flexibility for continued operation when appropriat< actions are taken to maintain safety functions. Immediate shutdown in accordance with TS 3.0.3 is not reasonable with more thaa one MS1V inoperable and tne appropriate actions satisfied. This change provides consistency with NUREG-1431.
- 5. In addition to the option to close the MSIV in Modes 2 and 3, this change provides for the return of the valte to operable status. Placing the valve in en operable condition without depending on action requirements is mere desirable than isolating the path or initiating a shutdown to lower modes. A time interval has been added to ensure the establishment of the safety function within a reasonable time regardless of the method used. This change provides consistency with NUREG-1431.
- 6. The addition of the seven-day verification provides confidence that the MSIV is closed and that the safety function is maintained. This provision supports the potential to be in this condition for a prolonged period of time. This change provides consistency with NUREG-1431.
El-2 m -
- i. The provision for separate entry into the Modes 2 and 3 actions for each MSIV clarifies the acceptability for multiple valves to be inoperable provided appropriate actions are taken. It also clarifies t' application of the action times such that each MSIV u weated individually for meeting the requirements of this e
action. This change provides consistency with NUREG- 14 31.
h 8. The addition of the actuation test is provided to ensure the entire main steam isolation function is propctly tested. SON reviews for Generic Letter 46-01 identified the lack of a TS requirament to test the end device for this function. This addition resolves this concern by requiring a test that verifies the MSIVs will close when an actuation signal from the colid a state protection system is generated. This change provides consistency with NUREG-1431.
III. SAFETY ANALYSIS h The MSIV.= are 32-inch globe valves that utilize air to open
[
E and spring u close. The MSIVs sre provided to protect the plant during breaks in the steam line upstream and
- downstream of the valves and steam generator (S/G) tube rupture events. The closure of the MSIVs ensures that no more than one S/G will blowdown for the steam-line break events. This closure will minimite the positive reactivity effects of the reactor coolant system cooldown resulting ,
from the blowdown and limit the pressure rise in containment for ruptures inside the containment structure.
For S/G tube rupture events, the MSIVs serve to limit the total amoust af primary coolant leakage by isolating ;he damaged SfG after pressure is reduced below shell side design pressure. The isolation of the steam line for this event does not require a fast operating MSIV. The MSIVs are capable of closing within the required actuation times assumed in the accident analysis.
P TVA proposes these change- to the SON TSs to provide consistency with NUREG-143J requirements. These changes will not alter the design or operating characteristics of the main steam isolation function.
y Some changes will !
enhance the requirements that ensure the MSIVs are operable by adding requirements for verifications that the valves
_ . are closed every seven days then inoperable and a new surveillance that provides end-dev4ce testing to verify the f actuation capability. Changes *o the allowed action times for inoperable MSIVs in Modes 2 and 3 could result in longer periods of time when the valves are not fully functional. The remaining changes do not reduce the effectiveness of the MSIV operability requirements, but do e
El-3 f p
provide reasonable provisjons consistent with the design of the MSIVs. Specific justifications-for the impact of each of the changes described above is as follows:
- 1. The LCO statement change to four MSIVs does not change the intent or application of TS requirements. There is no adverse impact to nuclear safety as a result of this change.
- 2. The removal of the option to close the MSIV in Mode 1 does not reduce safety. The current action for an inoperable MSIV in Mode 1 provides for continued operatica provided the valve is restored to operable status or closed. Closure of an MSIV in Mcde 1 could initiate severe S/G level problems that may result in a reactor trip. This result is more likely at higher power levels, but could also result at low power levels and unnecessarily challenge safety systems. The proposed requirement to raduce power to Mota 2 or lower, where the MSIVs can be safely closed, will provide adequate actions to estaolish the safety function of the valves in a reasonable length of time.
There is no adverse impact to nuclear safety as a result of this change. 1
- 3. The= current SON requirement for an Anoperable MSIV in Mode 1, that can not be restored to operable status within four hours, is a shutdown to Mode 3 in six hours and Mode 4 in the following six hours. This action is not reasonable when indefinite operation in Modes 2-and 3 is allowed by this specification. The proposed requirement te shutdown to Mode 2 will provide the appropriate actions to continue. shutdown to iower modes or establish conditions that ensure the safety functica of the "SIVs. Therefore, the current requirement is overly restrictive and requires the shutdown of the unit to an operating condition that may not be necessary. There is no adverse impact to nuclear safety as a result of this change. ;
- 4. The allowance to have one or more MSIVs inoperable in Modes ' and 3 is acceptable based on the proposed actions to allow continued operation in these modes.
These actions ensurc that the safety function of the MSIVs are established or requires a shutdown to Mode 4 where the MSIV safety function is not assumed in the accident analysia. If an MSIV continues to remain inoperable in Modes 2 and 3, the required actions will close and periodically verify that the valve is closed.
In the closed position, the MSIV satisfies the safety function to isolate steam flow. If these actions are maintair.ed for more than one MSIV, there will be no El-4
- - w
reduction in safety. There is no adverse impact to nuclear safety :s a result of this change.
- 5. The current SC" requirements for inoperable MSIVs in Modes 2 and 3 only provide actions te maintain the I
valves closed. This was based on the expectation that b
inoperable MSIVs would be closed when these modes were entered and did not specifically address valves becoming inoperable in these modes. The proposed
- hanges to the Mode 1 actions provide a more appropriato action that would require entry into Mode 2 with the inoperable valves open. Therefore, this change will provide the option to continue efforts to return the valve to operable status or to close the valve.
The addition of a four-hour time limit to establish operability or close the MSIV is provided because the valve may be open when entering this condition or become inoperable in these modes. This time ensures the establishment of the safety function in a
=asonable length of time considering the low
_obability of an accident occurring during this time period that would require closure of the MSIVs. This time limit, coupled with the Mode 1 action times, could allow an MSIV to-remain inoperable for up to 14 hours1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br /> prior to being closed. This time interval is within the potential 16-hour period that could result with the current require:..ents where an inoperable MSIV in Moce 1 could remain open while making the transition to Mode 4. The proposed change could result in a 26-hour period of time that an inoperable MSIV can be open from Mode 1 to Mode 4. This increase in time is acceptable based on the adoitional provisions to close or return the MSIV to operable status and the value of limiting shutdown activities when safety functions can be established in higher operating modes.
There is not a significant impact to nuclear safety as a result of this change.
- 6. The addition of this new action periodically verifies that the inoperable MSIVs are closed. This change ensures that inadvertent actions that could disable the safety function of the MSIVs do not go undetected for extended periods of time. This change enhances nuclear safety by providing additional verifications that eneure appropriate actions are in place for inoperable MSIVs. There is no adverse impact to nuclear safety as a result of this caange.
El-5 a
- 7. The addition of the action for Modes 2 and 3 that allows separate entry for each MSIV is a clarification of the current practice at SON. This type of action, where more than one component can be in the action, is treated this way unless specifically_ indicated otherwise. This addition to the specificatior. does not change this philosophy for the general application of the SQN TSs. The addition is proposed for clarification and for consistency with NUREG-1431.
There is no adverse impac^ to nuclear safety as a j result of this change.
- 8. The new surveillance to verify the closure of the MSIV.*
l on an actual or simulated automatic actuation signal provides additional assurance that the safety function of the valves is operable. Current requirements fail to ensure that the end device can be actuated from the solid state protection system. This addition will I implement the necessary tests that properly ensure the I
' opetability of the MSIVs and r.eet the expectations of NRC's Generic Letter 96-01. This surveillance has a 18 month frequency to provide for testing in lower modes during refueling outages. in these modes, this specification does not apply and operating conditions are such that this testing will not unnecessarily
, challenge unit systems. This change is an enhancement t
of the current SON surveillance requirements and nuclear safety is improved as a result of this change.
IV. NO SIGNIFICANT HAZARDS CONSIDERATION DETERMINATION TVA has conc]uded that operation of SQN Units 1 and 2, it accordance with the proposed change to the TSs, does not involve a significant hazards consideration. TVA's conclusion is based on its evaluation, in accordance with 10 CFR 50. 91(a) (1) , of the three standards set forth in 10 CFh 00.92(c).
A. The proposed amendment does not involve a significant increase in the probability or consequences of an accident previously evaluated.
The proposed changes provide enhancements and 1 clarifications of the requirements for inoperable MSIVs and periodic testing provisions. These changes do not alter the safety functions of the MSIVs or the operating practices that govern their application to plant conditions. The actions for Modes 2 and 3 are revised such that a longer time could occur before an inoperable MSIV is closed or the unit is placed in a mode that does not apply. However, this increase will El-6 i
not significantly impact the ability of the valves to mitigate an accident or affect the accident generation possibility. This is based on the low probabil!.ty of an accident occurring that would require closure of the MSIVs and reasonable time intervals to transition to lower modes based on operating experience to reach the required modes in an orderly manner without challenging unit systems.
The MSIVs provide accident mitigation functions, but do not contribute to accident generation. The MSIV functions have not been alt 2 red by the proposed changes. Therefore, the proposed changes will not increase the probability of a previously evaluated accident. Based on the above discussions, the l proposed changes will not significantly increase the consequences of an accident and in some instances they l will enhance the safety fu..ctions.
1 B. The proposed amendment does not create the possibility of a new or different kind of accident fron any accident previously evaluated.
The primary function of the MSIVs is to support accident mitigation and are not a significant
, contributor to events that could generate accidents.
The main impact that could result from an inoperable MSIV is an inadvertent closure that results in a unit trip. This event is bounded by the accidents that are currently evaluated for SQN. Since the proposed change does not alter MSIV funct cons and the new surveillance will be performed in modes that will not challenge unit systems, the possibility of a new or different kind of accident is not created.
C. The proposed-amandment does not involve a significant reduction in a margin of safety.
The proposed changes clarify and enhance the current SON requirements for the MSIVs with one exception.
This exception is the completion time added to the Modes 2 and 3 action that c,uld be a negative impact to the margin of safety. Inis change could allow the MSIV safety function to be inoperable for a longer period of time. The overall effect of the proposed changes considering the additional end-device testing, periodic verification of inoperable MSIV closure, and removal of the action to allew f1SIV closure in Mode 1, is considered a positive impact to the margin of safety. Therefore, there is not a significant reduction in the margin of safety.
El-7 i
- , , _)
V. ENVIRONMENTAL IMPACT CONSIDERATION The proposed change does not involve a significant hazards consideration, a significant char.ge in the types of or significant increase in the amounts of any effluents that may be released offsite, or a significant increase in individual or cumulative occupational radiation expostre. Therefore, the proposed change meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22 (c) (9) .
Therefore, pursuant to 10 CFR 51.22(b), an environmental assessment of the proposed change is not required.
I El-8
, . . . . , . . . _ . . . . . _ _ . . . . - _ _ _ _ . _ _ _