Insp Rept 50-382/97-09 on 970421-25.No Violations Noted. Major Areas Inspected:Plant Support,Including Implementation of Access Authorization Program,Background Procedures & Security BadgesML20148E287 |
Person / Time |
---|
Site: |
Waterford |
---|
Issue date: |
05/29/1997 |
---|
From: |
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
---|
To: |
|
---|
Shared Package |
---|
ML19063D048 |
List: |
---|
References |
---|
50-382-97-09, 50-382-97-9, NUDOCS 9706030055 |
Download: ML20148E287 (12) |
|
|
---|
Category:INSPECTION REPORT
MONTHYEARIR 05000382/19990201999-10-21021 October 1999 Insp Rept 50-382/99-20 on 990815-0925.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support Activities IR 05000382/19990141999-10-19019 October 1999 Insp Rept 50-382/99-14 on 990913-17 & 1004-08.No Violations Noted.Major Areas Inspected:Operator Requalification Training Program IR 05000382/19990181999-09-29029 September 1999 Insp Rept 50-382/99-18 on 990830-0902.Violations Noted.Major Areas Inspected:Implementation of NRC-approved Fire Protection Program IR 05000382/19990191999-09-27027 September 1999 Insp Rept 50-382/99-19 on 990830-0903.No Violations Noted. Major Areas Inspected:Plant Support IR 05000382/19990151999-09-14014 September 1999 Insp Rept 50-382/99-15 on 990719-23 with in Ofc Insp Until 0819.No Violations Noted.Major Areas Inspected:Assessment of 10CFR50.59 Safety Evaluation Program & Review of Previous Insp Findings Involving Tornado Missile Protection IR 05000382/19990071999-09-0808 September 1999 Insp Rept 50-382/99-07 on 990601-11.Noncited Violations Identified.Major Areas Inspected:Operations IR 05000382/19990161999-09-0101 September 1999 Insp Rept 50-382/99-16 on 990704-0814.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000382/19990101999-08-11011 August 1999 Insp Rept 50-382/99-10 on 990719-23.Violations Noted.Major Areas Inspected:Solid Radioactive Waste Mgt & Radioactive Matl Transportation Programs IR 05000382/19990131999-07-15015 July 1999 Insp Rept 50-382/99-13 on 990523-0703.Noncited Violations Noted.Major Areas Inspected:Aspects of Operations,Maint, Engineering & Plant Support Activities IR 05000382/19990121999-06-21021 June 1999 Insp Rept 50-382/99-12 on 990524-27.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000382/19990111999-06-18018 June 1999 Insp Rept 50-382/99-11 on 990524-28.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Effluent Mgt Program,Status of Effluent Radiation Monitors & Counting Room Instruments IR 05000382/19990091999-06-0303 June 1999 Insp Rept 50-382/99-09 on 990411-0522.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19990061999-05-18018 May 1999 Insp Rept 50-382/99-06 on 990405-09.Non-cited Violations Identified.Major Areas Inspected:Issue Previously Identified During Architect Engineering Insp Which Documented NRC Insp Rept 50-382/98-201 IR 05000382/19990051999-05-10010 May 1999 Insp Rept 50-382/99-05 on 990228-0410.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support ML20206F4801999-05-0303 May 1999 Insp Rept 50-382/99-08 on 990405-07.One Apparent Violation Noted & Being Considered for Escalated Eas.Major Areas Inspected:Plant Support Including Licensee Access Authorization Program IR 05000382/19990041999-04-0909 April 1999 Insp Rept 50-382/99-04 on 990301-19.One Violation Occurred & Being Treated as Noncited Violation.Major Areas Inspected: Review of Licensee Implementation of Facility ISI Program & Followup Review of Reactor Trip Breaker Performance IR 05000382/19990021999-04-0505 April 1999 Insp Rept 50-382/99-02 on 990117-0227.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support Activities IR 05000382/19990031999-03-26026 March 1999 Insp Rept 50-382/99-03 on 990308-12.Violations Noted.Major Areas Inspected:Radiation Protection Program Focusing on RF09 Refueling Outage Activities IR 05000382/19990011999-03-0303 March 1999 Partially Deleted Insp Rept 50-382/99-01 on 990125-29 & 0208-12 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Plant Support IR 05000382/19980181998-12-21021 December 1998 Insp Rept 50-382/98-18 on 981018-1128.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19980151998-11-24024 November 1998 Insp Rept 50-382/98-15 on 980906-1017.No Violations Noted. Major Areas Inspected:Aspects of Operations,Maint, Engineering & Plant Support Activities IR 05000382/19980131998-11-17017 November 1998 Insp Rept 50-382/98-13 on 980831-0901 & 981005-08.No Violations Noted.Major Areas Inspected:Maint Using Guidance of Temp Instruction 2515/137, Insp of Medium-Voltage & Low-Voltage Power Circuit Breakers ML20155D0561998-10-29029 October 1998 Insp Rept 50-382/98-17 on 981005-08.Violations Noted. Major Areas Inspected:Routine Review of Radiation Protection Program Activities ML20155D5111998-10-27027 October 1998 Partially Withheld Insp Rept 50-382/98-16 on 980914-18. Violations Noted.Major Areas Inspected:Licensee Physical Security Program.Portions Withheld (Ref 10CFR2.790) ML20154L1281998-10-0909 October 1998 Insp Rept 50-382/98-14 on 980726-0905.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19980121998-08-21021 August 1998 Insp Rept 50-382/98-12 on 980614-0725.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19992011998-07-27027 July 1998 Insp Rept 50-382/99-201 on 990511-0619.No Violations Noted Major Areas Inspected:Engineering IR 05000382/19980101998-07-20020 July 1998 Insp Rept 50-382/98-10 on 980622-26.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Protected Area Access Control of Personnel & Packages & Vehicles IR 05000382/19980091998-07-10010 July 1998 Insp Rept 50-382/98-09 on 980503-0613.Violations Noted.Major Areas Inspected:Aspects of Operations,Maint,Engineering & Plant Support Activities.Fire Door in Reactor Auxiliary Bldg Was Observed to Be Open W/No Controls in Place IR 05000382/19980081998-05-29029 May 1998 Insp Rept 50-382/98-08 on 980322-0502.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20217B6981998-04-21021 April 1998 Insp Rept 50-382/98-06 on 980201-0321.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000382/19980021998-03-20020 March 1998 Insp Rept 50-382/98-02 on 980202-20.No Violations Noted. Major Areas Inspected:Current Performance & Effectiveness of Corrective Action Program Including Audits & Assessments, Operations & Engineering ML20216E1461998-03-12012 March 1998 Insp Rept 50-382/98-07 on 980302-06.Violations Noted.Major Areas Inspected:Plant Support ML20216E5991998-03-12012 March 1998 Insp Rept 50-382/98-05 on 980202-12.Violations Noted.Major Areas Inspected:Licensee Physical Security Program ML20216E7621998-03-12012 March 1998 Insp Rept 50-382/97-25 on 971201-980205.Violations Noted. Major Areas Inspected:Maint & Engineering IR 05000382/19980031998-03-10010 March 1998 Insp Rept 50-382/98-03 on 980216-20.No Violations Noted. Major Areas Inspected:Operational Status of Emergency Preparedness Program ML20203L2171998-03-0303 March 1998 Insp Rept 50-382/98-04 on 980202-06.Violations Noted.Major Areas Inspected:Radiation Protection Program Including External Exposure Controls,Training Qualifications, Facilities & Equipment & Procedures & Documentation IR 05000382/19970281998-02-11011 February 1998 Insp Rept 50-382/97-28 on 971214-980131.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Activities IR 05000382/19980011998-01-29029 January 1998 Insp Rept 50-382/98-01 on 980112-15.No Violations Noted. Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radwaste/Matls Transportation Program.Quality Assurance Oversight,Training & Procedural Guidance Were Also Reviewed ML20198M2801998-01-12012 January 1998 Insp Rept 50-382/97-24 on 971102-1213.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198C8871998-01-0505 January 1998 Insp Rept 50-382/97-26 on 971117-1205.No Violations Noted. Major Areas Inspected:Operator Activities Re Failure to Return Valve ACC-126A,auxiliary Component CWS Flow Control Valve,To Automatic Operation When Restoring CWS ML20198C4561998-01-0202 January 1998 Insp Rept 50-382/97-27 on 971117-1205.Violations Noted. Major Areas Inspected:Review of Licensee Identification That Plant Ventilation Sys Could Adversely Affect Level Indication for Refueling Water Storage Pool IR 05000382/19970181997-12-0505 December 1997 Insp Rept 50-382/97-18 on 971104-07.Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures Performed IR 05000382/19970211997-12-0202 December 1997 Insp Rept 50-382/97-21 on 970922-26 & 1006-10.Violation Noted.Major Areas Inspected:Engineering,Maintenance & Mgt Meetings IR 05000382/19970221997-11-19019 November 1997 Insp Rept 50-382/97-22 on 970921-0001.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19970231997-11-0404 November 1997 Insp Rept 50-382/97-23 on 971006-10.No Violations Noted. Major Areas Inspected:Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls & Radioactive Effluent Monitoring IR 05000382/19970191997-10-24024 October 1997 Partially Withheld Insp Rept 50-382/97-19 on 970922-26 (Ref 10CFR73.21).No Violations Identified.Major Areas Inspected: Plant Support Re Land Vehicle Control Measures & Security Program IR 05000382/19970171997-10-23023 October 1997 Insp Rept 50-382/97-17 on 970929-1003.Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program Following Guidelines in Insp Procedure 71001, Licensed Operator Requalification Program Evaluation IR 05000382/19970161997-10-17017 October 1997 Insp Rept 50-382/97-16 on 970810-0920.Violations Noted: Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19970201997-10-0909 October 1997 Insp Rept 50-382/97-20 on 970922-26.Violations Noted.Major Areas Inspected:External & Internal Exposure Control Programs,Surveys,Monitoring & Control of Radioactive Matl & Quality Assurance 1999-09-08
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000382/19990201999-10-21021 October 1999 Insp Rept 50-382/99-20 on 990815-0925.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support Activities IR 05000382/19990141999-10-19019 October 1999 Insp Rept 50-382/99-14 on 990913-17 & 1004-08.No Violations Noted.Major Areas Inspected:Operator Requalification Training Program IR 05000382/19990181999-09-29029 September 1999 Insp Rept 50-382/99-18 on 990830-0902.Violations Noted.Major Areas Inspected:Implementation of NRC-approved Fire Protection Program IR 05000382/19990191999-09-27027 September 1999 Insp Rept 50-382/99-19 on 990830-0903.No Violations Noted. Major Areas Inspected:Plant Support IR 05000382/19990151999-09-14014 September 1999 Insp Rept 50-382/99-15 on 990719-23 with in Ofc Insp Until 0819.No Violations Noted.Major Areas Inspected:Assessment of 10CFR50.59 Safety Evaluation Program & Review of Previous Insp Findings Involving Tornado Missile Protection IR 05000382/19990071999-09-0808 September 1999 Insp Rept 50-382/99-07 on 990601-11.Noncited Violations Identified.Major Areas Inspected:Operations IR 05000382/19990161999-09-0101 September 1999 Insp Rept 50-382/99-16 on 990704-0814.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000382/19990101999-08-11011 August 1999 Insp Rept 50-382/99-10 on 990719-23.Violations Noted.Major Areas Inspected:Solid Radioactive Waste Mgt & Radioactive Matl Transportation Programs IR 05000382/19990131999-07-15015 July 1999 Insp Rept 50-382/99-13 on 990523-0703.Noncited Violations Noted.Major Areas Inspected:Aspects of Operations,Maint, Engineering & Plant Support Activities IR 05000382/19990121999-06-21021 June 1999 Insp Rept 50-382/99-12 on 990524-27.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000382/19990111999-06-18018 June 1999 Insp Rept 50-382/99-11 on 990524-28.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Effluent Mgt Program,Status of Effluent Radiation Monitors & Counting Room Instruments IR 05000382/19990091999-06-0303 June 1999 Insp Rept 50-382/99-09 on 990411-0522.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19990061999-05-18018 May 1999 Insp Rept 50-382/99-06 on 990405-09.Non-cited Violations Identified.Major Areas Inspected:Issue Previously Identified During Architect Engineering Insp Which Documented NRC Insp Rept 50-382/98-201 IR 05000382/19990051999-05-10010 May 1999 Insp Rept 50-382/99-05 on 990228-0410.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support ML20206F4801999-05-0303 May 1999 Insp Rept 50-382/99-08 on 990405-07.One Apparent Violation Noted & Being Considered for Escalated Eas.Major Areas Inspected:Plant Support Including Licensee Access Authorization Program IR 05000382/19990041999-04-0909 April 1999 Insp Rept 50-382/99-04 on 990301-19.One Violation Occurred & Being Treated as Noncited Violation.Major Areas Inspected: Review of Licensee Implementation of Facility ISI Program & Followup Review of Reactor Trip Breaker Performance IR 05000382/19990021999-04-0505 April 1999 Insp Rept 50-382/99-02 on 990117-0227.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support Activities IR 05000382/19990031999-03-26026 March 1999 Insp Rept 50-382/99-03 on 990308-12.Violations Noted.Major Areas Inspected:Radiation Protection Program Focusing on RF09 Refueling Outage Activities IR 05000382/19990011999-03-0303 March 1999 Partially Deleted Insp Rept 50-382/99-01 on 990125-29 & 0208-12 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Plant Support IR 05000382/19980181998-12-21021 December 1998 Insp Rept 50-382/98-18 on 981018-1128.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19980151998-11-24024 November 1998 Insp Rept 50-382/98-15 on 980906-1017.No Violations Noted. Major Areas Inspected:Aspects of Operations,Maint, Engineering & Plant Support Activities IR 05000382/19980131998-11-17017 November 1998 Insp Rept 50-382/98-13 on 980831-0901 & 981005-08.No Violations Noted.Major Areas Inspected:Maint Using Guidance of Temp Instruction 2515/137, Insp of Medium-Voltage & Low-Voltage Power Circuit Breakers ML20155D0561998-10-29029 October 1998 Insp Rept 50-382/98-17 on 981005-08.Violations Noted. Major Areas Inspected:Routine Review of Radiation Protection Program Activities ML20155D5111998-10-27027 October 1998 Partially Withheld Insp Rept 50-382/98-16 on 980914-18. Violations Noted.Major Areas Inspected:Licensee Physical Security Program.Portions Withheld (Ref 10CFR2.790) ML20154L1281998-10-0909 October 1998 Insp Rept 50-382/98-14 on 980726-0905.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19980121998-08-21021 August 1998 Insp Rept 50-382/98-12 on 980614-0725.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19992011998-07-27027 July 1998 Insp Rept 50-382/99-201 on 990511-0619.No Violations Noted Major Areas Inspected:Engineering IR 05000382/19980101998-07-20020 July 1998 Insp Rept 50-382/98-10 on 980622-26.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Protected Area Access Control of Personnel & Packages & Vehicles IR 05000382/19980091998-07-10010 July 1998 Insp Rept 50-382/98-09 on 980503-0613.Violations Noted.Major Areas Inspected:Aspects of Operations,Maint,Engineering & Plant Support Activities.Fire Door in Reactor Auxiliary Bldg Was Observed to Be Open W/No Controls in Place IR 05000382/19980081998-05-29029 May 1998 Insp Rept 50-382/98-08 on 980322-0502.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20217B6981998-04-21021 April 1998 Insp Rept 50-382/98-06 on 980201-0321.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000382/19980021998-03-20020 March 1998 Insp Rept 50-382/98-02 on 980202-20.No Violations Noted. Major Areas Inspected:Current Performance & Effectiveness of Corrective Action Program Including Audits & Assessments, Operations & Engineering ML20216E1461998-03-12012 March 1998 Insp Rept 50-382/98-07 on 980302-06.Violations Noted.Major Areas Inspected:Plant Support ML20216E5991998-03-12012 March 1998 Insp Rept 50-382/98-05 on 980202-12.Violations Noted.Major Areas Inspected:Licensee Physical Security Program ML20216E7621998-03-12012 March 1998 Insp Rept 50-382/97-25 on 971201-980205.Violations Noted. Major Areas Inspected:Maint & Engineering IR 05000382/19980031998-03-10010 March 1998 Insp Rept 50-382/98-03 on 980216-20.No Violations Noted. Major Areas Inspected:Operational Status of Emergency Preparedness Program ML20203L2171998-03-0303 March 1998 Insp Rept 50-382/98-04 on 980202-06.Violations Noted.Major Areas Inspected:Radiation Protection Program Including External Exposure Controls,Training Qualifications, Facilities & Equipment & Procedures & Documentation IR 05000382/19970281998-02-11011 February 1998 Insp Rept 50-382/97-28 on 971214-980131.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Activities IR 05000382/19980011998-01-29029 January 1998 Insp Rept 50-382/98-01 on 980112-15.No Violations Noted. Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radwaste/Matls Transportation Program.Quality Assurance Oversight,Training & Procedural Guidance Were Also Reviewed ML20198M2801998-01-12012 January 1998 Insp Rept 50-382/97-24 on 971102-1213.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198C8871998-01-0505 January 1998 Insp Rept 50-382/97-26 on 971117-1205.No Violations Noted. Major Areas Inspected:Operator Activities Re Failure to Return Valve ACC-126A,auxiliary Component CWS Flow Control Valve,To Automatic Operation When Restoring CWS ML20198C4561998-01-0202 January 1998 Insp Rept 50-382/97-27 on 971117-1205.Violations Noted. Major Areas Inspected:Review of Licensee Identification That Plant Ventilation Sys Could Adversely Affect Level Indication for Refueling Water Storage Pool IR 05000382/19970181997-12-0505 December 1997 Insp Rept 50-382/97-18 on 971104-07.Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures Performed IR 05000382/19970211997-12-0202 December 1997 Insp Rept 50-382/97-21 on 970922-26 & 1006-10.Violation Noted.Major Areas Inspected:Engineering,Maintenance & Mgt Meetings IR 05000382/19970221997-11-19019 November 1997 Insp Rept 50-382/97-22 on 970921-0001.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19970231997-11-0404 November 1997 Insp Rept 50-382/97-23 on 971006-10.No Violations Noted. Major Areas Inspected:Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls & Radioactive Effluent Monitoring IR 05000382/19970191997-10-24024 October 1997 Partially Withheld Insp Rept 50-382/97-19 on 970922-26 (Ref 10CFR73.21).No Violations Identified.Major Areas Inspected: Plant Support Re Land Vehicle Control Measures & Security Program IR 05000382/19970171997-10-23023 October 1997 Insp Rept 50-382/97-17 on 970929-1003.Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program Following Guidelines in Insp Procedure 71001, Licensed Operator Requalification Program Evaluation IR 05000382/19970161997-10-17017 October 1997 Insp Rept 50-382/97-16 on 970810-0920.Violations Noted: Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19970201997-10-0909 October 1997 Insp Rept 50-382/97-20 on 970922-26.Violations Noted.Major Areas Inspected:External & Internal Exposure Control Programs,Surveys,Monitoring & Control of Radioactive Matl & Quality Assurance 1999-09-08
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000382/19990201999-10-21021 October 1999 Insp Rept 50-382/99-20 on 990815-0925.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support Activities IR 05000382/19990141999-10-19019 October 1999 Insp Rept 50-382/99-14 on 990913-17 & 1004-08.No Violations Noted.Major Areas Inspected:Operator Requalification Training Program PNO-IV-99-038A, on 990929,restart of Waterford 3 Occurred. Cause Identified as Failed Seal Water Heat Exchanger Baffle. New Battle & Seal Assembled Were Installed & Reactor Coolant Pump 2B Was Returned to Svc Satisfactorily1999-10-0101 October 1999 PNO-IV-99-038A:on 990929,restart of Waterford 3 Occurred. Cause Identified as Failed Seal Water Heat Exchanger Baffle. New Battle & Seal Assembled Were Installed & Reactor Coolant Pump 2B Was Returned to Svc Satisfactorily IR 05000382/19990181999-09-29029 September 1999 Insp Rept 50-382/99-18 on 990830-0902.Violations Noted.Major Areas Inspected:Implementation of NRC-approved Fire Protection Program IR 05000382/19990191999-09-27027 September 1999 Insp Rept 50-382/99-19 on 990830-0903.No Violations Noted. Major Areas Inspected:Plant Support PNO-IV-99-038, on 990910,operators Manually Tripped Reactor from 100% Power in Response to Indications of Failure of RCP 2B Seal.New Baffle & Seal Assembly Were Installed & Plant Was Returned to Power Operations on 9908101999-09-15015 September 1999 PNO-IV-99-038:on 990910,operators Manually Tripped Reactor from 100% Power in Response to Indications of Failure of RCP 2B Seal.New Baffle & Seal Assembly Were Installed & Plant Was Returned to Power Operations on 990810 IR 05000382/19990151999-09-14014 September 1999 Insp Rept 50-382/99-15 on 990719-23 with in Ofc Insp Until 0819.No Violations Noted.Major Areas Inspected:Assessment of 10CFR50.59 Safety Evaluation Program & Review of Previous Insp Findings Involving Tornado Missile Protection IR 05000382/19990071999-09-0808 September 1999 Insp Rept 50-382/99-07 on 990601-11.Noncited Violations Identified.Major Areas Inspected:Operations IR 05000382/19990161999-09-0101 September 1999 Insp Rept 50-382/99-16 on 990704-0814.Noncited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support PNO-IV-99-032A, on 990801,Waterford 3 Operators Manually Tripped Reactor from 100% Power in Response to Indications of Failure of RCP 2B Seal.Pump Was Secured Immediately Following Plant Sd.New Baffle & Seal Assembly Was Installed1999-08-12012 August 1999 PNO-IV-99-032A:on 990801,Waterford 3 Operators Manually Tripped Reactor from 100% Power in Response to Indications of Failure of RCP 2B Seal.Pump Was Secured Immediately Following Plant Sd.New Baffle & Seal Assembly Was Installed IR 05000382/19990101999-08-11011 August 1999 Insp Rept 50-382/99-10 on 990719-23.Violations Noted.Major Areas Inspected:Solid Radioactive Waste Mgt & Radioactive Matl Transportation Programs PNO-IV-99-032, on 990801,Waterford 3 Operators Manually Tripped Reactor from 100% Power in Response to Indications of Failure of RCP 2B Seal.Pump Was Secured Immediately Following Plan Shutdown.Resident Inspectors Will Monitor1999-08-0303 August 1999 PNO-IV-99-032:on 990801,Waterford 3 Operators Manually Tripped Reactor from 100% Power in Response to Indications of Failure of RCP 2B Seal.Pump Was Secured Immediately Following Plan Shutdown.Resident Inspectors Will Monitor IR 05000382/19990131999-07-15015 July 1999 Insp Rept 50-382/99-13 on 990523-0703.Noncited Violations Noted.Major Areas Inspected:Aspects of Operations,Maint, Engineering & Plant Support Activities IR 05000382/19990121999-06-21021 June 1999 Insp Rept 50-382/99-12 on 990524-27.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000382/19990111999-06-18018 June 1999 Insp Rept 50-382/99-11 on 990524-28.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Effluent Mgt Program,Status of Effluent Radiation Monitors & Counting Room Instruments ML20196C9461999-06-15015 June 1999 Notice of Violation from Insp Completed on 990422.Violation Noted:Licensee Failed to Consider Info Contained During Background Investigation Before Granting Temporary Unescorted Access to Contractor Employee IR 05000382/19990091999-06-0303 June 1999 Insp Rept 50-382/99-09 on 990411-0522.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20209B8581999-05-25025 May 1999 EN-98-046A:on 990524,staff Withdrew Proposed Civil Penalty in Amount of $110,000 Issued to Licensee.Action Based on Severity Level III Problems Associated with ECCS & Afws IR 05000382/19990061999-05-18018 May 1999 Insp Rept 50-382/99-06 on 990405-09.Non-cited Violations Identified.Major Areas Inspected:Issue Previously Identified During Architect Engineering Insp Which Documented NRC Insp Rept 50-382/98-201 IR 05000382/19990051999-05-10010 May 1999 Insp Rept 50-382/99-05 on 990228-0410.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support ML20206F4801999-05-0303 May 1999 Insp Rept 50-382/99-08 on 990405-07.One Apparent Violation Noted & Being Considered for Escalated Eas.Major Areas Inspected:Plant Support Including Licensee Access Authorization Program IR 05000382/19990041999-04-0909 April 1999 Insp Rept 50-382/99-04 on 990301-19.One Violation Occurred & Being Treated as Noncited Violation.Major Areas Inspected: Review of Licensee Implementation of Facility ISI Program & Followup Review of Reactor Trip Breaker Performance IR 05000382/19990021999-04-0505 April 1999 Insp Rept 50-382/99-02 on 990117-0227.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support Activities IR 05000382/19990031999-03-26026 March 1999 Insp Rept 50-382/99-03 on 990308-12.Violations Noted.Major Areas Inspected:Radiation Protection Program Focusing on RF09 Refueling Outage Activities IR 05000382/19990011999-03-0303 March 1999 Partially Deleted Insp Rept 50-382/99-01 on 990125-29 & 0208-12 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Plant Support ML20207F1581999-03-0303 March 1999 Notice of Violation from Insp on 990125-29 & 0208-12. Violation Noted:Inspector Determined That Waterford Audits SA-98-025.1 & SA-98-036.1,dtd 980916,were Conducted by Individuals Not Independent of Program Mgt Being Audited IR 05000382/19980181998-12-21021 December 1998 Insp Rept 50-382/98-18 on 981018-1128.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19980151998-11-24024 November 1998 Insp Rept 50-382/98-15 on 980906-1017.No Violations Noted. Major Areas Inspected:Aspects of Operations,Maint, Engineering & Plant Support Activities PNO-IV-98-054, on 981117,plant Shutdown Greater than 72 H Due to Unidentified Leak.Investigations by Licensee Verified That Leakage Occurred from RCP 2b Seal Area1998-11-19019 November 1998 PNO-IV-98-054:on 981117,plant Shutdown Greater than 72 H Due to Unidentified Leak.Investigations by Licensee Verified That Leakage Occurred from RCP 2b Seal Area IR 05000382/19980131998-11-17017 November 1998 Insp Rept 50-382/98-13 on 980831-0901 & 981005-08.No Violations Noted.Major Areas Inspected:Maint Using Guidance of Temp Instruction 2515/137, Insp of Medium-Voltage & Low-Voltage Power Circuit Breakers ML20155D0561998-10-29029 October 1998 Insp Rept 50-382/98-17 on 981005-08.Violations Noted. Major Areas Inspected:Routine Review of Radiation Protection Program Activities ML20155D0411998-10-29029 October 1998 Notice of Violation from Insp on 981005-08.Violation Noted: Inspectors Identified That Radiation Surveys to Evaluate Extent of Radiation Levels Had Not Been Performed Prior to Operations Personnel Entering Area ML20155D5111998-10-27027 October 1998 Partially Withheld Insp Rept 50-382/98-16 on 980914-18. Violations Noted.Major Areas Inspected:Licensee Physical Security Program.Portions Withheld (Ref 10CFR2.790) ML20155D5021998-10-27027 October 1998 Notice of Violation from Insp on 980914-18.Violation Noted: Performance Tests of Protected Area Detection Sys Identified That Two Detection Zones Did Not Meet Design Criteria to Detect Test Individuals ML20154L0831998-10-0909 October 1998 Notice of Violation from Insp on 980726-0905.Violation Noted:On 980721,NRC Inspectors Found Door 206,vital Area Portal,Unlocked & Not in Alarm at Central Alarm Station ML20154L1281998-10-0909 October 1998 Insp Rept 50-382/98-14 on 980726-0905.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support PNO-IV-98-045, on 980926,Unit 3 Declared Unusual Event of Hurricane Warning in St Charles Parish.River Bend Station Continued to Operate at Full Power Since Hurricane Force Winds Were Not Predicted in Vicinity of Site1998-09-28028 September 1998 PNO-IV-98-045:on 980926,Unit 3 Declared Unusual Event of Hurricane Warning in St Charles Parish.River Bend Station Continued to Operate at Full Power Since Hurricane Force Winds Were Not Predicted in Vicinity of Site PNO-IV-98-040, on 980917,licensee Commenced Shutdown of Reactor in Order to Replace Pressurizer Code Safety Valve That Had Been Experiencing Increased Leakage.Licensee Plans to Restart Facility on 9809231998-09-18018 September 1998 PNO-IV-98-040:on 980917,licensee Commenced Shutdown of Reactor in Order to Replace Pressurizer Code Safety Valve That Had Been Experiencing Increased Leakage.Licensee Plans to Restart Facility on 980923 IR 05000382/19980121998-08-21021 August 1998 Insp Rept 50-382/98-12 on 980614-0725.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000382/19992011998-07-27027 July 1998 Insp Rept 50-382/99-201 on 990511-0619.No Violations Noted Major Areas Inspected:Engineering IR 05000382/19980101998-07-20020 July 1998 Insp Rept 50-382/98-10 on 980622-26.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Protected Area Access Control of Personnel & Packages & Vehicles ML20236P2431998-07-10010 July 1998 Notice of Violation from Insp on 980503-0613.Violation Noted:On 980521,AP UNT-005-013 Was Not Implemented in That Impairment to Fire Door D150 Was Not Controlled IR 05000382/19980091998-07-10010 July 1998 Insp Rept 50-382/98-09 on 980503-0613.Violations Noted.Major Areas Inspected:Aspects of Operations,Maint,Engineering & Plant Support Activities.Fire Door in Reactor Auxiliary Bldg Was Observed to Be Open W/No Controls in Place ML20249A9611998-06-16016 June 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $100,000.Violation Noted:Licensee Identified That Calculated Peak Fuel Cladding Temp Would Have Exceeded 2200 F Using Licensing Basis Analysis & HPSI Flow ML20151R9131998-06-0909 June 1998 EN-98-046:on 980616,notice of Proposed Imposition of Civil Penalty in Amount of $110,000 Issued to Licensee.Action Based on Level III Problem Involving HPSI Flow Issues at Waterford-3 Facility IR 05000382/19980081998-05-29029 May 1998 Insp Rept 50-382/98-08 on 980322-0502.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20248F6801998-05-29029 May 1998 Notice of Violation from Insp on 980322-0502.Violation Noted:Licensee Failed to Establish Adequate Procedures for Operation of EDG When in No or Low Electrical Loading Condition in That No Specific Guidance Provided IR 05000382/19980991998-04-24024 April 1998 SALP Rept 50-382/98-99 for 961201-980321 ML20217B6731998-04-21021 April 1998 Notice of Violation from Insp on 980201-0321.Violation Noted:On Past Occasions,Engineer Operated Governor Valve on Emergency Feedwater Turbine W/O Direction or Concurrence of Shift Superintendent or Control Room Supervisor ML20217B6981998-04-21021 April 1998 Insp Rept 50-382/98-06 on 980201-0321.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering 1999-09-08
[Table view] |
See also: IR 05000382/1997009
Text
.
.
ENCLOSURE 2
U.S. NUCLEAR REGULATORY COMMISSION
REGION IV
Docket No.; 50-382
License No.: NPF-38
Report No.: 50-382/97-09
Licensee: Entergy Operations, Inc.
Facility: Waterford Steam Electric Station, Unit 3
Location: Hwy,18
Killona, Louisiana
l
Dates: April 21-25,1997
Inspector: Thomas W. Dexter, Senior Physical Security Specialist
Plant Support Branch
Approved By: Blaine Murray, Chief, Plant Support Branch
Division of Reactor Safety
ATTACHMENT: Supplemental information
l
.
9706030055 970529
PDR ADOCK 05000382
G PDR
_._ . . _ _ . _ . ._ . . . . _ . _ . _ _ _ _ _ . _ _ _ . _ _ _ -~._._ _ ___ .__._ _ _
- . -
i
,
i
h
,
-
2
- >
$. ,
'
!
l !
! EXECUTIVE SUMMARY !
j Waterford Steam Electric Station, Unit 3 i
i NRC Inspection Report 50-382/97-09-
!
!
I
PJLant Suonort
! l
l *- Implementation of the access authorization program was not fully effective. In l
l genera' the security staff was knowledgeable of regulatory requirements and -
- performed their duties satisfactorily. Management support for the program was
j very good (Section S1.1). i
j
- * Background investigations were completed in a comprehensive and thorough
l manner in accordance with proper regulations, the physical security plan, and
i procedural requirements (Section 1.2).
!
i * The licensee had implemented proper procedures for the behavioral observation
i program. However, ineffective implementation of the behavioral observation
l program by one contractor caused the licensee to be in violation of regulatory
i requirements (Section 1.3).
!
1
- A violation was identified involving the assignment of a security badge to a
{ contractor who had been terminated. The reinstaternent, updating, transfer, and {
j temporary access program elements, were generally administered in accordance j
i with rule requirements (Section 1.4). l
I
! ' * A program for denying or revoking unescorted access was in place but was not ,
being followed by a contractor. Two violations were identified involving the failure
, of a contractor to notify the licensee of individuals who no longer required
i unescorted access (Section 1.5).
1
4
l * A violation was identified involving an inattentive security officer posted at the vital
i area equipment hatch into reactor containment (Section S4).
3
$
i
l
i
!
4
}
a
i
!
?
1
4
, -
,-. _
.._-.m ~r -
---a ,-
- _ . . _ _ . _ _ _ . _ _ _ _ . _ _ _ _ _ _ _ . _ _ . - . _ _ _ . . _ _ _
j.
i
!
..
,
.
-3-
l
]
a
.
Report Details
i
4
l
This reactive inspection, conducted in accordance with NRC Inspection
- Manual 2515A/81700, " Physical Security Program for Power Reactors," dated April 15,
- 1994, assessed the continued effective implementation of the licensee's access )
authorization program,
]
a
j; S1 Conduct of Accep Authorization Program Activities
4
1
l S1.1 Access Authorization Program Activities and Organization
.
a. insoection Scope 81700
l
The inspector evaluated the access authorization program administration and
- implementation through the assessment of management involvement, oversight and i
j support of the program, structure and interfaces of the organization, the authorities
and responsibilities assigned, and the specialized training and work experience of
l
- key program personnel.
. i
) b. Observations and Findinas
,
! On April 18,1997, Region IV was informed that 10 individuals had been granted
unauthorized access to the protected area. In response to this information a
security inspector was dispatched to the site on April 21,1997, to review the
! access authorization issues.
!
j The licensee's access authorization program was conducted from an office located
- at the plant site outside of the protected area. Responsibility for overall
! management of the program was assigned to the corporate security department.
l The plant manager or his designee was responsible for making a final determination
- whether unescorted access would be granted.
!
i On April 18,1997, The Director, Plant Modification and Construction, in a
j conversation with an individual seeking employment with a contractor on site was
informed that the individual was not currently employed, but was badged as a
i Stone and Webster employee. l
s
!
!
'
The Director questioned the ability of someone to have unescorted access to the
plant protected area and not be employed by a contractor at the site and
immediately informed the Director, Site Support. The Director, Site Support
informed the Superintendent, Plant Security and discussed the situation with
badging personnel. ;
1
- - - . - . .- . -
.
.
4
Personnel in badging confirmed that the subject individual was badged and the
Director, Site Support ordered the badge be inactivated. Badging personnel began
investigating the situation; and, based on their c'urrent in-processing list for the
upcoming week, noted that an additional individual was badged but not employed
by a contractor at the time. The Director, Site Support ordered that individual's
badge also be inactivated.
Badging ersonnel continued their investigation of the situation and the Director,
Site Support informed the Vice Presidera, Operations of the situation. In addition,
the Director, Site Support requested Superintendent, Plant Security to check the use
of badges by these individuals. Badging personnel's investigation determined that 8
other individuals had been issued a badge who apparently were not currently
employed by a contractor at the site. Plant access involving the badges was also
checked and it was determined that one individual was in the plant at the time.
Security personnel were directed to find the individual and escort him to the
security office. This was accomplished and further investigation determined that
the individual was employed by a contractor at the site.
Based on the one individual being in the plant and the potential for additional
unemployed personnel to be in the plant and not under a continuous behavioral
observation program supervisor, a decision was made to lock allingress and egress
from the primary access point and begin a one-on-one verification process.
The General Manager, Plant Operations and the Control Room were notified of the
action being taken. Licensing and security personnel began developing a condition
report and the NRC Headquarters Operations Center was r.otified.
Following further discussion the General Manager, Plant Operations was requested
to initiate a controlled evacuation of the plant of all non-essential personnel. The
plan was to collect all of the key cards, place them in the card racks with tags and
begin reverifying each individual's access status.
Corporate Security personnel generated reports, by contractor, listing the names of
personnel assigned to the contractor who were issued a key card. These lists were
distributed to responsible contractor representatives with instructions to verify the
personnel assigned to their group, their employment status and need for unescorted
aCCOss.
An orderly evacuation of the plant was conducted and verification of plant
personnel was initiated at the primary access point by security as each individual
was allowed to reenter the protected area.
The licensee found two additional contractor employees who were working for a
contractor other than the contractor of record at the time. It was later determined
that these individuals had originally been processed for badging with one contractor
and changed to another contractor during the screening and badging process.
- . _ . - . . _ _ - - -- - . - . _ _ .
.,
.
5-
The inspector interviewed program administrators and site representatives and
determined they were knowledgeable of program responsibilities and performed their
duties satisfactorily. The inspector reviewed the utility's access authorization
program procedures and noted they contained the guidance necessary to implement
the program. However, problems were noted involving the revoking of unescorted
access,31 day reviews of access affecting the continuous behavioral observation
program, and issuing of badges / key cards after an individual has been terminated.
Three violations of access authorization requirements are discussed in
Sections S1.4 and S1.5.
c. Conclusions
!
! Implementation of the access authorization program was not fully effective resulting
,
in violations. However, the staff were knowledgeable and performed their duties
l satisfactorily. Management support for the program was very good.
I
S1.2 Background Investigations Elements
i a. Inspection Scope 81700
The inspector reviewed records and conducted interviews to determine the
adequacy of the program. The inspector also reviewed information concerning the
licensee's verification of identity, employment history, education history, credit
history, criminal his' Tory, military service, and the character and reputation of the
applicants, before granting individuals unescorted access to protected and vital
areas.
b. Observations and Findinos
The inspector verified documentation in 24 background files and determined that all
elements of a successful background investigation were completed in accordance
with the physical security plan and regulatory requirements. The inspector verified
that when the licensee reviewed periods of employment and unemployment, they i
also specifically verified employee activities during periods of unemployment.
c. Conclusions
Background investigations were completed in a comprehensive and thorough
manner in accordance with regulations, the physical security plan, and procedural l
requirements. l
A
.
6-
S 1.3 Behavioral Observation Program
a. Inspection Scone (81700)
The licensee's behavioral observation program was inspected t'o determine whether
supervisors and managers were meeting program requirements.
b. Observations and Findinas
The licensee's implementation of the continual behavior observation program
procedures was verified against the program requirements. The procedures covered
all of the program elements effectively. However, problems were identified with
one contractor's behavioral observation program. The contractor's weak program
contributed to the violations identified in Sections S1.4 and S1.5.
c. Conclusions
The licensee had implemented procedures for the behavioral observation program.
Ineffective implementation of the behavioral observation program by one contractor
caused the licensee to be in violation of their program.
St.4 Reinstatement, Updatina, Transfer and Temocrary Unescorted Access Authorization
a. Inspection Scoce 81700
The inspector reviewed the licensee's program for reinstatement, updating, transfer,
and temporary unescoited access, to insure compliance with requirements. l
b. Observations and Findinos
A review of 24 access authorization files of reinstatement, updating, transfer,
and/or temporary unescorted access on individuals was completed. The licensee
had ensured that all requirements were met prior to granting unescorted access to
all but one of the 24 individuals. That one exception involved the granting of
unescorted access to an individual after he had been terminated by the contractor.
The contractor had failed to inform the licensee of the termination as required oy
the security plan and implementing procedures.
Waterford 3 Physical Security Plan, Revision 17, dated August 1996, Chapter 5,
paragraph 5.2.1, " Personnel Access Authorization," states, in part, "U.nescorted
access into the protected area is limited to those individuals who meet the Entergy
screening requirements and who have a leoitimate reason for entry. . . .
Authorizations for unescorted personnel access to the protected area are issued by
the General Manager, Plant Operations, his casignee, or Duty Plant Manager (s),
after a reason for entry has been established."
__ _ .
- . . .- _- . -. _ -
.
.
-7-
Attachment NUMARC 89-01, to Regulatory Guide 5.66, June 1991, paragraph 3.0,
" Responsibility," states, in part, "The final granting and controlling of unescorted
access authorization is the responsibility of the utility. Each nuclear utility will
inform contractors and vendors of the existence of these guidelines and of the
necessity to follow these guidelines."
Security Procedure PS-011-107, " Badge / Key Card Assignment and Control,"
Revision 10, February 16,1995, paragraph 5.2.1 states, in part, ". . . photo
badge / key cards shall be assigned to individuals by a badging and in-processing
administrative specialist after the following criteria have been met: 1. A supervisor
requests that the individual be authorized unescorted access . . . In addition
paragraph 5.10 states, in part, the security department must be notified whenever
.. the access authorization of the assigned person is terminated."
On April 23,1997, the inspector identified that on March 25,1997, a photo
badge / key card had been assigned to a contractor employee who had been
terminated by the contractor on March 21,1997, and no longer had a need to enter
the plant. The licensee had deleted the badge from the computer system on
April 21,1997. The assignment of a security badge to an individual who had
been terminated is a violation of the security plan and Procedute PS-011-107
(50-382/9709-03).
c. Conclusions
The reinstatement, updating, transfer, and temporary access program elements,
were administered in accordance with rule requirements. One violation of NRC
program requirements was identified related to assignment of a security badge to an
individual who had been terminated.
SI.5 Denial or Revocation of Unescorted Access
a. Inspection Scope 81700
A review of the licensee's system for denial or revocation of unescorted access
authorization was conducted to determine if the licensee had implemented a proper
procedure for the denial or revocation of unescorted access of an employee of the
licensee, contractor, or vendor.
b. Observations and Findinas
The licensee had implemented procedures for revocation of unescorted access of an
employee of the licensee, contractor, or vendor. However, the inspector identified
the following probierns regarding procedure implementation.
J
- _
'
.
t
.
-8- l
l
l
Waterford 3 Physical Security Plan, Revision 17, dated August 1996, Chapter 2,
paragraph 2.3.1, " Personnel Screening and Access Authorization," states, in part,
"Entergy Operations, Inc., Waterford 3, commits to Regulatory Guide 5.66, Access
Authorization Program for Nuclear Power Plants dated June 1991. All regulatory
elements have been implemented to satisfy the requirements of 10 CFR 73.56." In
addition paragraph 5.2.1, " Personnel Access Authorization," states, in part, l
" Unescorted access into the protected area is limited to those individuals who meet
the Entergy screening requirements and who have a legitimate reason for entry.
. . Authorizations for unescorted personnel access to the protected area are issued
by the General Manager, Plant Operations, his designee, or Duty Plant Manager (s), )
after a reason for entry has been established." l
l
Attachment NUMARC 89-01, to Regulatory Guide 5.66, June 1991, paragraph 3.0, !
" Responsibility," states, in part, "The final granting and controlling of unescorted
access authorization is the responsibility of the utility. Each nuclear utility will
inform contractors and vendors of the existence of the these guidelines and of the
necessity to follow these guidelines."
Waterford 3 Procedure OM-106, " Unescorted Access Authorization Program," !
Revision 2, April 28,1996, paragraph 5.8 states, in part, "All company officers,
directors, managers, superintendents, eupervisors and their t.ppointed designees are l
responsible for: Taking appropriate acuan to ensure that individuals under their I
authority with unescorted access, . . . who no longer need unescorted access, have
their unescorted access terminated . . . ."
Site Directive W2.102, " Employee Termination and Resignation Practices," j
Revision 1, April 29,1994, paragraph 4.3 states, in part, "The Director, General
Manager-Plant Operations and/or concerned Manager or Supervisor is responsible
for: ensuring that information pertaining to the reason and condition associated
with all terminations and resignations is relayed to the Waterford 3 Security
Superintendent prior to or concurrently with the employee's departure from the
plant site."
On April 18,1997, the licensee determined that the Waterford 3 Security
Superintendent had not been notified prior to or concurrently of the termination
of approximately 10 contract employees. Active badge / key cards were available
to those employees after they no longer had a need for unescorted access into the
protected area. In some cases, those active badges / key cards were on file at the
badge issue station 30 days or more after the contract employee's termination.
The failure to terminate badges for contract employees that had no need for
unescorted access to the protected area is a violction of security procedures
(50-382/97-09-01).
__ _ _ _ _ _ _ _ . . . _ - _ _ _ _ _ . _ . . . _ _ _ _ _ _ . _ _ . _ _ _ .
. ;
i'
)
- *
1
h
j '
'
- -9-
I
!
4
1 .
.
'
Waterford 3 Physical Security Plan, Revision 17, dated August 1996,
]
j paragraph 5.2.2 states, in part, "A list of personnel authorized unescorted access ;
i
to the protected and vital areas is located at the Primary Access Point for use by
the security department and is reviewed by cognizant supervisors / managers every
31 days and updated as applicable."
,
Waterford 3 Procedure OM-110, " Continual Behavioral Observation Program,"
Revision 0, March 31,1995, paragraph 6.2.3a. states, in part, "Each month, an
unescorted access verification report is generated by the site access or security ,
section and provided to the cognizant department heads. The purpose of the report
is to verify that individuals with current unescorted access continue to have a valid -
need for unescorted access."
r
On April 23,1997, the inspector identified that on April 1,1997, a contractor ,
supervisor signed the 31 day access review record for his department indicating he i
had reviewed the record and no changes were required. However, that record had !
approximately four individuals listed who had not used their unescorted access in ;
excess of 30 days and two individuals who had been terminated days prior to the
required review date. Those individuals no longer had a need for unescorted access i
into the protected area. The failure to update the access authorization list is a i
violation of the security plan and Procedure OM-110 (50-382/9709-02). j
c. Conclusions 1
?
!
A program for denying or revoking unescorted access was in place, but was not ,
being followed by a contractor. The failure by the contractor to notify the licensee i
of individuals who no longer needed unescorted access resulted in two violations of i
NRC requirements.
S4 Access Control of Personnel
a. Insoection Scoce (81700-02.05)
During a walk down of refueling outage activities another NRC inspector observed a
security officer posted as a compensatory measure to control access into
containment from the protected area.
b. Observations and Findinas
On April 23,1997, an NRC inspector, accompanied by a licensee representative,
were exiting the reactor containment building at the west side access point when
the inspector noticed a security officer who appeared to be asleep. The security
officer was wearing sun glasses and sitting in a swivel type office chair. To the j
inspector it appeared that the security officer was responsible for controlling access
into containment through the equipment hatch. The inspector approached the
security officer and waved his hand in front of the security officer's face. The
1
i
e
e
-10-
security officer did not respond. The inspector then taped the security officer on
the shoulder and the officer was startled. The inspector asked the officer if he was ,
alright and then who his supervisor was. The officer gave the inspector the name l
of his supervisor. The licensee's representative called the security manager, who
had the officer relieved of duty.
Waterford 3 Physical Security Plan, Revision 17, dated March 1996, Chapter 10
states, in part, " Exterior doors to vital areas utilized for the movement of special
equipment during refueling and major maintenance operations are controlled, when
in use, by security personnel. When frequent access to containment is pctmitted
during refueling or major mainteriance, positive access control will be maintained for
access from the protected area into containment."
Licensee Administrative Procedure UNT-004-036, " Security Requirements for !
Penetrating PA & VA Barriers," Revision 3, January 7,1997, paragraph 4.3, "PA &
VA Barriers," states, in part, "The Security Officer (S.O.) posted for a security
learrier penetration or approved activity in an outer isolation zone is responsible for
access control to the affected area."
Security Procedure PS-016-101, " Security Procedure During Refueling and Major I
Maintenance Operations," Revision 8, June 19,1996, paragraph 5.2.3 states, in ;
part, "When frequent access to containment is permitted during refueling or major '
maintenance, positive access control will be maintained from the protected area into
containment (which is a vital area). If the door at the protected area to vital area j
barrier is circumvented it must then be posted by an armed security officer who i
must control entry and exit through the door."
On April 23,1997, during refueling, an inspector determined that the licensee failed
to maintain positive access control to a vital area. Specifically, an NRC inspector,
accompanied by a licensee employee, identified that a security officer posted as a
compensatory measure at the equipment hatch entrance to containment was
inattentive. The failure to maintain proper vital area access control is a violation of
the security plan and procedure PS-016-101 (50-382/9709-04).
c. Conclusion
A security officer was inattentive at the vital area equipment hatch into reactor
containment that resulted in a violation of NRC requirements.
V. Manaaement Meetinas
X1 Exit Summary
The inspector presented the inspection results to members of the licensee management at
the conclusion of the inspection on April 25,1997. The licensee acknowledged the
finoings presented. No proprietary information was identified.
. .. _ - _. - . _ - - . . - . .-
. o
,
,
,
l
ATTACHMENT
i SUPPLEMENTAL INFORMATION
1
l PARTIAL LIST OF PERSONS CONTACTED
Licensee
C. Dugger, Vice President Nuclear Operations
E. Beckendorf, Superintendent, Plant Security
R. Bitner, Project Manager, Wackenhut
H. Cooper. Manager, Corporate Security
F. Drummond, Director, Site Support
R. Dawdy, Acting Security Supervisor (Corporate Security)
E. Ewing, Director, Nuclear Safety and Regulatory Aff airs
T. Gaudet, Manager, Licensing
J. Lewis, Emergency Planning Manager
D. Pintado, Coordinator, Nuclear Security
G. Scott, Licensing Engineer
L. Thomas, Licensing Supervisor
G. Wilson, Acting Quality Assurance Manager
NRC
P. Harrell, Chief, Division Reactor Projects Branch D
T. Pruett, Resident Inspector
W. McNeill, Reactor inspector
INSPECTION PROCEDURES USED
iP 81700 Physical Security Program for Power Reactors
ITEMS OPENED, CLOSED, AND DISCUSSED
Opened
1
I
50-382/9709-01 VIO Failure To Terminate Active Key Cards for Terminated
'
Employees
50-382/9709-02 VIO Inadequate 31-Day Access List Review
50-382/9709-03 VIO Temporary Unescorted Access Granted without Background
Investigation Screening Completed
50-382/9709-04 VIO Inattentive Security Officer at Vital Area Door
i
!
- - . . - . . . . . - . . - . . . . . . . . ~ - . - - - . _ - - .. . -. ~ . . . - . . . .
4 .*
9
O
,
, -2-
1
->
$
,
PARTIAL LIST OF LICENSEE DOCUMENTS REVIEWED
24 Selected Background investigation Files
Waterford 3 Physical Security Plan, Revision 17, dated August 1996
31-Day Access Review Update files signed by mangers
Selected Condition Reports for 1997
Licensee Procedures
Security Procedure PS-011-107, Badge / Key Card Assignment and Control, Revision 10,
February 16,1995
,
Waterford 3 Procedure OM-110, Continual Behavioral Observation Program, Revision 0,
March 31,1995
Security Procedure PS-016-101, Security Procedure During Refueling and Major <
Maintenance Operations, Revision 8, June 19,1996
Licensee Administrative Procedure UNT-004-036, Security Requirements for Penetrating i
PA & VA Barriers, Revision 3, January 7,1997
Waterford 3 Procedure OM-106, Unescorted Access Authorization Program, Revision 2,
April 28,1996
l
,
l
i
j
!