Defective Motor Shaft Keys in Limitorque Motor ActuatorsML031150062 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Issue date: |
10/20/1988 |
---|
From: |
Rossi C Office of Nuclear Reactor Regulation |
---|
To: |
|
---|
References |
---|
IN-88-084, NUDOCS 8810140018 |
Download: ML031150062 (3) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>. |
4.
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION
WASHINGTON, D.C. 20555 October 20, 1988 NRC INFORMATION NOTICE NO. 88-84: DEFECTIVE MOTOR SHAFT KEYS IN LIMITORQUE
MOTOR ACTUATORS
Addressees
All holders of operating licenses or construction permits for nuclear power
reactors.
Purpose
This information notice is being provided to alert recipients to potential
problems from defective motor shaft keys installed in certain Limitorque
actuators. It is expected that recipients will review the information for
applicability to their facilities and consider actions, as appropriate, to
avoid similar problems. However, suggestions contained in this information
notice do not constitute NRC requirements; therefore, no specific action or
written response is required.
Description of Circumstances
On October 15, 1987, the NRC received a report from Houston Lighting and Power
Company concerning sheared motor shaft-to-pinion keys found in a Limitorque
actuator at its South Texas Project, Unit 2, nuclear plant. A similar key
'failure also occurred in April 1987. The sheared key from one of the valves.
was sent to a metallurgical laboratory which found that the properties of the
-. material were not consistent with those of American Iron and Steel Institute
(AISI) type 1018 steel. AISI type 1018 steel is the material designated by
Limitorque for these particular keys as specified in Limitorque design documents.
In August 1987, three additional keys had been removed from similar actuators
and sent to the laboratory for analysis. One of the removed keys was split
and the other two showed signs of deformation. Laboratory analysis of these
keys revealed that the properties of the key material were not consistent with
those of AISI type 1018 steel. The metallurgical analysis revealed that the
keys had failed longitudinally along manganese sulfide inclusions and that the
key material was probably an AISI type 1118 or 1119 resulphurized steel. Addi- tionally, on March 16, 1983, Westinghouse had submitted a 10 CFR Part 21 report
to the NRC concerning its discovery of sheared keys on six actuators. These
keys were also analyzed and found to be made of other than AISI type 1018 steel.
Discussion:
During an NRC inspection at Limitorque in May 1988, inspectors found that at
the time of the manufacture of the South Texas actuators, keys were purchased
<0 At101t40018
IN 88-84 October 20, 1988 from a commercial vendor without certificates of conformance for the material
type or properties. No checks were performed at Limitorque to verify that the
proper key material was received. Keys purchased today are still bought as
commercial grade; however, certified material test reports (CMTRs) are received
from the vendor. Limitorque also performs hardness and dimensional checks of
the keys upon receipt from the vendor.
In a letter to the NRC dated May 19, 1988, Limitorque provided additional in- formation on this issue. Limitorque stated that the current material control
procedures for key procurement were fully implemented in September 1983. At
that time, the existing key inventory was scrapped and completely replaced with
keys purchased under the new controls. It is estimated that all actuators from
serial number 362735 onward were supplied with keys procured under the upgraded
material controls. Additionally, Limitorque determined that only the following
actuator-motor combinations could potentially experience similar key failures
due to improper material.
Unit Size Motor Size
SMB-000 None
SMB-OO 25-ft.lb 1800 rpm
SMB-0 25-ft.lb 1800 rpm
25-ft.ThY -3600 rpm--
40-ft.lb 1800 rpm
SMB-1 60-ft.lb 1800 rpm
60-ft.lb 3600 rpm
SMB-2 80-ft.lb 3600 rpm
No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the technical
contact listed below or the Regional Administrator of the appropriate regional
office.
Division of Operational Events Assessment
Office of Nuclear Reactor Regulation
Technical Contact:
Jeffrey B. Jacobson, NRR
(301) 492-0996 Attachment: List of Recently Issued NRC Information Notices
,0 A -%If
Attachment
IN 88-84 October 20, 1988 LIST OF RECENTLY ISSUED
NRC INFORMATION NOTICES
Information Date of
Notice No. Subject Issuance Issued to
88-83 Inadequate Testing of Relay 10/19/88 All holders of OLs
Contacts in Safety-Related or CPs for nuclear
Logic Systems power reactors.
88-82 Torus Shells with Corrosion 10/14/88 All holders of OLs
and Degraded Coatings in or CPs for BWRs.
BWR Containments
88-81 Failure of Amp Window 10/7/88 All holders of OLs
Indent Kynar Splices or CPs for nuclear
and Thomas and Betts power, test, and
Nylon Wire Caps During research reactors.
Environmental Quali- fication Testing
88-80 Unexpected Piping Movement 10/7/88 All holders of OLs
Attributed to Thermal or CPs for PWRs.
Stratification
88-79 Misuse of Flashing Lights 10/7/88 All holders of OLs
for High Radiation Area or CPs for nuclear
Controls power reactors.
88-69, Supp 1 Movable Contact Finger 9/29/88 All holders of OLs
Binding in HFA Relays or CPs for nuclear
Manufactured by General power reactors.
Electric (GE)
88-78 Implementation of Revised 9/22/88 All holders of OLs
NRC-Administered Requali- or CPs for nuclear
fication Examinations power reactors.
88-77 Inadvertent Reactor 9/22/88 All holders of OLs
Vessel Overfill or CPs for BWRs.
88-76 Recent Discovery of a 9/19/88 All holders of OLs
Phenomenon not Previously or CPs for nuclear
Considered in the Design power reactors.
of Secondary Containment
Pressure Control
OL = Operating License
CP = Construction Permit
|
---|
|
list | - Information Notice 1988-01, Safety Injection Pipe Failure (27 January 1988)
- Information Notice 1988-03, Cracks in Shroud Support Access Hole Cover Welds (2 February 1988, Topic: Stolen)
- Information Notice 1988-04, Inadequate Qualification and Documentation of Fire Barrier Penetration Seals (5 February 1988, Topic: Fire Barrier, Fire Watch, Stolen)
- Information Notice 1988-05, Fire in Annunciator Control Cabinets (12 February 1988, Topic: Stolen)
- Information Notice 1988-06, Foreign Objects in Steam Generators (29 February 1988, Topic: Stolen)
- Information Notice 1988-07, Inadvertent Transfer of Licensed Material to Uncontrolled Locations (7 March 1988, Topic: Stolen)
- Information Notice 1988-08, Chemical Reactions with Radioactive Waste Solification Agents (14 March 1988, Topic: Process Control Program, Stolen)
- Information Notice 1988-09, Reduced Reliability of Steam-Driven Auxiliary Feedwater Pumps Caused by Instability of Woodward PG-PL Type Governors (18 March 1988)
- Information Notice 1988-10, Memo of Understanding Between NRC and OSHA Relating to NRC-Licensed Facilities (53 FR 43950, October 31, 1988) (23 December 1988)
- Information Notice 1988-10, Memo of Understanding Between NRC and OSHA Relating to NRC-Licensed Facilities (53 Fr 43950, October 31, 1988) (23 December 1988)
- Information Notice 1988-10, Memorandum of Understanding Between NRC and Osha Relating to NRC-Licensed Facilities (53 Fr 43950, October 31, 1988. (23 December 1988)
- Information Notice 1988-11, Potential Loss of Motor Control Center And/Or Switchboard Function Due to Faulty Tie Bolts (7 April 1988)
- Information Notice 1988-12, Overgreasing of Electric Motor Bearings (12 April 1988)
- Information Notice 1988-13, Water Hammer & Possible Piping Damage Caused by Misapplication of Kerotest Packless Metal Diaphragm Globe Valves (18 April 1988)
- Information Notice 1988-14, Potential Problems with Electrical Relays (18 April 1988)
- Information Notice 1988-15, Availability of Us Food & Drug Administration (FDA) Approved Potassium Iodide for Use in Emergencies Involving Radioactive Iodine (18 April 1988)
- Information Notice 1988-15, Availability of Us Food & Drug Administration (Fda) Approved Potassium Iodide for Use in Emergencies Involving Radioactive Iodine (18 April 1988)
- Information Notice 1988-16, Identify Waste Generators in Shipments of Low-Level Waste to Land Disposal Facilities (22 April 1988)
- Information Notice 1988-17, Summary of Responses to NRC Bulletin 87-01, Thinning of Pipe Walls in Nuclear Power Plants. (22 April 1988, Topic: Safe Shutdown, Weld Overlay, Through-Wall Leak)
- Information Notice 1988-18, Malfunction of Lockbox on Radiography Device (25 April 1988)
- Information Notice 1988-19, Questionable Certification of Class Ie Components (26 April 1988)
- Information Notice 1988-19, Questionable Certification of Class IE Components (26 April 1988)
- Information Notice 1988-20, Unauthorized Individuals Manipulating Controls and Performing Control Room Activities (5 May 1988)
- Information Notice 1988-21, Inadvertent Criticality Events at Oskarshamn and at U.S. Nuclear Power Plants (9 May 1988, Topic: Shutdown Margin)
- Information Notice 1988-22, Disposal of Sludge from Onsite Sewage Treatment Facilities at Nuclear Power Stations (12 May 1988)
- Information Notice 1988-23, Potential for Gas Binding of High-Pressure Safety Injection Pumps During a Loss-Of-Coolant Accident (12 May 1988)
- Information Notice 1988-24, Failures of Air-Operated Valves Affecting Safety-Related Systems (13 May 1988)
- Information Notice 1988-25, Minimum Edge Distance for Expansion Anchor Bolts (16 May 1988, Topic: Earthquake)
- Information Notice 1988-26, Falsified Pre-Employment Screening Records (16 May 1988)
- Information Notice 1988-27, Deficient Electrical Terminations Identified in Safety-Related Components (18 May 1988)
- Information Notice 1988-28, Potential for Loss of Post-Loca Recirculation Capability Due to Insulation Debris Blockage (19 May 1988, Topic: Coatings)
- Information Notice 1988-29, Deficiencies in Primary Containment Low-Voltage Electrical Penetration Assemblies (24 May 1988)
- Information Notice 1988-30, Target Rock Two-State SRV Setpoint Drift Update (25 May 1988)
- Information Notice 1988-31, Steam Generator Tube Rupture Analysis Deficiency (25 May 1988)
- Information Notice 1988-32, Prompt Reporting to NRC of Significant Incidents Involving Radioactive Material (25 May 1988)
- Information Notice 1988-33, Recent Problems Involving the Model Spec 2-T Radiographic Exposure Device (27 May 1988)
- Information Notice 1988-34, Nuclear Material Control & Accountability of Non-Fuel Special Nuclear Material at Power Reactors (31 May 1988)
- Information Notice 1988-36, Possible Sudden Loss of RCS Inventory During Low Coolant Level Operation (8 June 1988)
- Information Notice 1988-37, Flow Blockage of Cooling Water to Safety System Components (14 June 1988, Topic: Ultimate heat sink)
- Information Notice 1988-38, Failure of Undervoltage Trip Attachment of General Electric Circuit Breakers (15 June 1988)
- Information Notice 1988-39, Loss of Recirculation Pumps with Power Oscillation Event (15 June 1988)
- Information Notice 1988-40, Examiners' Handbook for Developing Operator Licensing Examinations (22 June 1988)
- Information Notice 1988-41, Physical Protection Weaknesses Identified Through Regulatory Effectiveness Reviews (RERs) (22 June 1988)
- Information Notice 1988-41, Physical Protection Weaknesses Identified Through Regulatory Effectiveness Reviews (Rers) (22 June 1988)
- Information Notice 1988-42, Circuit Breaker Failures Due to Loose Charging Spring Motor Mounting Bolts (23 June 1988, Topic: Loctite)
- Information Notice 1988-43, Solenoid Valve Problems (23 June 1988, Topic: Stroke time)
- Information Notice 1988-44, Mechanical Binding of Spring Release Device in Westinghouse Type DS-416 Circuit Breakers (24 June 1988)
- Information Notice 1988-45, Problems in Protective Relay & Circuit Breaker Coordination (7 July 1988, Topic: Safe Shutdown)
- Information Notice 1988-46, Licensee Report of Defective Refurbished Circuit Breakers (8 July 1988)
- Information Notice 1988-47, Slower-than-Expected Rod-drop Times (14 July 1988)
... further results |
---|