ML18159A039: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 15: Line 15:


=Text=
=Text=
{{#Wiki_filter:NTS June 6, 2018 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001  
{{#Wiki_filter:NTS June 6, 2018 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001


==Subject:==
==Subject:==
Potential Part 21 on Dedicated Items not available for PMI testing (NUPIC) Pursuant to the requirements of 10 CFR Part 21, this letter notifies the NRC of a potential and indetermi n ate Part 21 condition.
Potential Part 21 on Dedicated Items not available for PMI testing (NUPIC)
NUPIC Audit Report 24393, Finding 170310029-02 identified a weakness in NTS' material dedication of items based on visual comparison of items being dedicated to seismically qualified test specimens and not actual verification of material type. Since the i s sue of the finding, NTS has performed positive material identification (PMI) testing of the seismically important components of the seismically qualified test specimens and a representative of each type of item dedicated during the last three years, with exception of a few items. NTS needs a representative of each of these few items to complete the testing and is requesting each affected customer to return one of each item on the attached list if possible for testing. For those utilities that provide a representative item, NTS will provide PMI test results. NTS is noti f ying the affected customers of this potential Part 21 condition in parallel with this notification.
Pursuant to the requirements of 10 CFR Part 21, this letter notifies the NRC of a potential and indeterminate Part 21 condition. NUPIC Audit Report 24393, Finding 170310029-02 identified a weakness in NTS' material dedication of items based on visual comparison of items being dedicated to seismically qualified test specimens and not actual verification of material type.
Since the issue of the finding, NTS has performed positive material identification (PMI) testing of the seismically important components of the seismically qualified test specimens and a representative of each type of item dedicated during the last three years, with exception of a few items. NTS needs a representative of each of these few items to complete the testing and is requesting each affected customer to return one of each item on the attached list if possible for testing. For those utilities that provide a representative item, NTS will provide PMI test results.
NTS is notifying the affected customers of this potential Part 21 condition in parallel with this notification.
Note: Based on NTS' evaluation of the results to-date, the dedicated materials are equal to or better than the seismically qualified material.
Note: Based on NTS' evaluation of the results to-date, the dedicated materials are equal to or better than the seismically qualified material.
Thank you for your consideration in this matter and if you have any questions, please contact NTS' Senior Director of Nuclear Engineering and Test Services, Tom Brewington at (256) 716-4512 or email at tom.brewington@nts.com. Sincerely, . .JI.__.-~----~-*--***--------C....:> Megan Toomey Sr. Contracts Manager NTS Huntsville NTS Huntsville
Thank you for your consideration in this matter and if you have any questions, please contact NTS' Senior Director of Nuclear Engineering and Test Services, Tom Brewington at (256) 716-4512 or email at tom.brewington@nts.com .
Sincerely,
    . - ~~  .JI.__. -~- --- ~-*--***- --- ----
C....:>
Megan Toomey Sr. Contracts Manager NTS Huntsville NTS Huntsville
* 7800 Highway 20 West
* 7800 Highway 20 West
* Huntsville , AL 35806 * (256) 837-4411
* Huntsville, AL 35806 * (256) 837-4411
* Fax: (256) 830-2109
* Fax: (256) 830-2109
* www.nts.com Items not available for testing (NUPIC) Cust o mer approved NO. ITEM CUSTOMER CUSTOMER PO# NTS PROJECT# Notes Ded Plan? 1 Fisher 3710-1 Pneumatic Valve Positioner Dominion -Millstone 4500366063 PR061801 Have test specimen; Need representative sample yes 2 Sola/Hevi-Duty 23-23-210-8 Transformer Duke Energy -Robinson 03018277 PR046127 No test specimen; Need representative sample no 03052327 PR066932 no 3 Yokogawa 103122AXXX Panel Meter, Type DB-Entergy -Arkansas Nuclear One 10480763 Rev 1 PR048591 Have test specimen; Need representative sample; yes 40 Obso l ete, Yokogawa no longer manufactures Yokogawa 180183HEAA8ABA Panel Meter Exelon -Oyster Creek 80071876 PR052431 yes and 4 Have test spec i men; Need representative sample; results Yokogawa 180183HXAA8ABA Panel Meter Georgia Power -Hatch SNG10105647 Rev 1 PR036337 Obsolete , Yokogawa no longer manufactures yes 5 Action Instruments 4380-2001-D Signal Exelon -Calvert Cliffs Conditioner 00565752 PR043012 No test specimen; Need representat i ve sample no 10467951 Rev 0 0 3 PR043492 Have test specimen; Need representative sample yes and results 6 Ametek SC-1302 VDl-Al-1-Nl-NR-FS Signal Entergy -Pilgrim 10490895 Rev 003 PR053343 Have test specimen; Need representative samp l e yes and Converter results 10496592 Rev 002 Have test spec i men; Need representative sample yes and PR055646 10498845 Rev 003 results 7 Magnatrol B15-4H3 B-COK Level Sw i tch Duke Energy -Brunswick 03026047 PR050517 Have test specimen; Need representative sample no Page 1 of 1}}
* www.nts.com
 
Items not available for testing (NUPIC)
Customer approved NO.                     ITEM                             CUSTOMER                 CUSTOMER PO#           NTS PROJECT#                         Notes                   Ded Plan?
1 Fisher 3710-1 Pneumatic Valve Positioner Dominion - Millstone                   4500366063             PR061801   Have test specimen; Need representative sample     yes 03018277              PR046127                                                      no 2 Sola/Hevi-Duty 23-23-210-8 Transformer   Duke Energy - Robinson                                                   No test specimen; Need representative sample 03052327               PR066932                                                       no Yokogawa 103122AXXX Panel Meter, Type DB-                                                                           Have test specimen; Need representative sample; 3                                            Entergy - Arkansas Nuclear One       10480763 Rev 1           PR048591                                                       yes 40                                                                                                                 Obsolete, Yokogawa no longer manufactures yes and Yokogawa 180183HEAA8ABA Panel Meter       Exelon - Oyster Creek                   80071876               PR052431   Have test specimen; Need representative sample;   results 4
Obsolete, Yokogawa no longer manufactures Yokogawa 180183HXAA8ABA Panel Meter       Georgia Power - Hatch             SNG10105647 Rev 1           PR036337                                                       yes Action Instruments 4380-2001-D Signal 5                                            Exelon - Calvert Cliffs                 00565752               PR043012   No test specimen; Need representat ive sample       no Conditioner yes and 10467951 Rev 003          PR043492   Have test specimen; Need representative sample results Ametek SC-1302 VDl-Al-1-Nl-NR-FS Signal                                                                                                                             yes and 6                                            Entergy - Pilgrim                   10490895 Rev 003           PR053343   Have test specimen; Need representative sample Converter                                                                                                                                                             results 10496592 Rev 002                                                                       yes and PR055646  Have test specimen; Need representative sample 10498845 Rev 003                                                                       results 7 Magnatrol B15-4H3 B-COK Level Sw itch    Duke Energy - Brunswick                 03026047               PR050517   Have test specimen; Need representative sample     no Page 1 of 1}}

Latest revision as of 23:41, 20 October 2019

National Technical Systems (Nts) - Potential Part 21 on Dedicated Items Not Available for Pmi Testing (NUPIC)
ML18159A039
Person / Time
Site: Millstone, Hatch, Calvert Cliffs, Oyster Creek, Pilgrim, Arkansas Nuclear, Brunswick
Issue date: 06/06/2018
From: Toomey M
National Technical Systems
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML18159A039 (2)


Text

NTS June 6, 2018 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Potential Part 21 on Dedicated Items not available for PMI testing (NUPIC)

Pursuant to the requirements of 10 CFR Part 21, this letter notifies the NRC of a potential and indeterminate Part 21 condition. NUPIC Audit Report 24393, Finding 170310029-02 identified a weakness in NTS' material dedication of items based on visual comparison of items being dedicated to seismically qualified test specimens and not actual verification of material type.

Since the issue of the finding, NTS has performed positive material identification (PMI) testing of the seismically important components of the seismically qualified test specimens and a representative of each type of item dedicated during the last three years, with exception of a few items. NTS needs a representative of each of these few items to complete the testing and is requesting each affected customer to return one of each item on the attached list if possible for testing. For those utilities that provide a representative item, NTS will provide PMI test results.

NTS is notifying the affected customers of this potential Part 21 condition in parallel with this notification.

Note: Based on NTS' evaluation of the results to-date, the dedicated materials are equal to or better than the seismically qualified material.

Thank you for your consideration in this matter and if you have any questions, please contact NTS' Senior Director of Nuclear Engineering and Test Services, Tom Brewington at (256) 716-4512 or email at tom.brewington@nts.com .

Sincerely,

. - ~~ .JI.__. -~- --- ~-*--***- --- ----

C....:>

Megan Toomey Sr. Contracts Manager NTS Huntsville NTS Huntsville

  • 7800 Highway 20 West
  • Huntsville, AL 35806 * (256) 837-4411
  • Fax: (256) 830-2109
  • www.nts.com

Items not available for testing (NUPIC)

Customer approved NO. ITEM CUSTOMER CUSTOMER PO# NTS PROJECT# Notes Ded Plan?

1 Fisher 3710-1 Pneumatic Valve Positioner Dominion - Millstone 4500366063 PR061801 Have test specimen; Need representative sample yes 03018277 PR046127 no 2 Sola/Hevi-Duty 23-23-210-8 Transformer Duke Energy - Robinson No test specimen; Need representative sample 03052327 PR066932 no Yokogawa 103122AXXX Panel Meter, Type DB- Have test specimen; Need representative sample; 3 Entergy - Arkansas Nuclear One 10480763 Rev 1 PR048591 yes 40 Obsolete, Yokogawa no longer manufactures yes and Yokogawa 180183HEAA8ABA Panel Meter Exelon - Oyster Creek 80071876 PR052431 Have test specimen; Need representative sample; results 4

Obsolete, Yokogawa no longer manufactures Yokogawa 180183HXAA8ABA Panel Meter Georgia Power - Hatch SNG10105647 Rev 1 PR036337 yes Action Instruments 4380-2001-D Signal 5 Exelon - Calvert Cliffs 00565752 PR043012 No test specimen; Need representat ive sample no Conditioner yes and 10467951 Rev 003 PR043492 Have test specimen; Need representative sample results Ametek SC-1302 VDl-Al-1-Nl-NR-FS Signal yes and 6 Entergy - Pilgrim 10490895 Rev 003 PR053343 Have test specimen; Need representative sample Converter results 10496592 Rev 002 yes and PR055646 Have test specimen; Need representative sample 10498845 Rev 003 results 7 Magnatrol B15-4H3 B-COK Level Sw itch Duke Energy - Brunswick 03026047 PR050517 Have test specimen; Need representative sample no Page 1 of 1