=Text=
=Text=
{{#Wiki_filter:}}
{{#Wiki_filter:FSAR CHAPTER 14 - SAFETY ANALYSIS                                                                                TABLE 14.11-3                                                                                                                                                                    Revision 32                                                                                                                                                                      Page 1 of 1
 
in
 
FSAR CHAPTER 14 - SAFETY ANALYSIS                                                                            TABLE 14.14-7 Revision 28
 
Page 1 of 1
 
MAIN STEAM LINE BREAK (MSLB) RADIOLOGICAL ANALYSIS - INTACT SG STEAM RELEASE RATE
 
Time (hours) Intact SG Steam Release (lb m) 0 - 8 800,000 8 - 720.0 0 
 
FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.15-8 Revision 28 Page 1 of 1 SGTR RADIOLOGICAL ANALYSIS - 40 CI/GM D.E. I-131 ACTIVITIES Isotope Activity Ci/gm) Iodine-131 33.2194 Iodine-132 7.6660 Iodine-133 34.4971 Iodine-134 3.0025 Iodine-135 14.6932 
 
FSAR CHAPTER 14 - SAFETY ANALYSISTABLE 14.17.3-2Revision 30 Page 1 of 1ASYMMETRIC LOADS ANALYSIS - REACTOR VESSELINTERNAL COMPONENT STRESS MARGINSComponent LocationPercent Margin
(%)*Core Support BarrelUpper Flange 6Upper Cylinder 7Center Cylinder 11Lower Support StructureSupport Columns 2Beams 3Core Support Plate 13 Upper Guide StructureGrid Beams 1*Percent margin is computed as (Sallow - Scalc) (100%) / Sallow, where Scalc is thecalculated component stress and Sallow is the ASME Code allowable stress.
 
X/Q    (1) bounding X/Q values used for FHA, SLBOC and SFCD  (2) bounding X/Q values used for SGTR
 
FSAR CHAPTER 14 - SAFETY ANALYSIS                                                                                TABLE 14.11-3                                                                                                                                                                    Revision 32                                                                                                                                                                      Page 1 of 1
 
in
 
FSAR CHAPTER 14 - SAFETY ANALYSIS                                                                            TABLE 14.14-7 Revision 28
 
Page 1 of 1
 
MAIN STEAM LINE BREAK (MSLB) RADIOLOGICAL ANALYSIS - INTACT SG STEAM RELEASE RATE
 
Time (hours) Intact SG Steam Release (lb m) 0 - 8 800,000 8 - 720.0 0 
 
FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.15-8 Revision 28 Page 1 of 1 SGTR RADIOLOGICAL ANALYSIS - 40 CI/GM D.E. I-131 ACTIVITIES Isotope Activity Ci/gm) Iodine-131 33.2194 Iodine-132 7.6660 Iodine-133 34.4971 Iodine-134 3.0025 Iodine-135 14.6932 
 
FSAR CHAPTER 14 - SAFETY ANALYSISTABLE 14.17.3-2Revision 30 Page 1 of 1ASYMMETRIC LOADS ANALYSIS - REACTOR VESSELINTERNAL COMPONENT STRESS MARGINSComponent LocationPercent Margin
(%)*Core Support BarrelUpper Flange 6Upper Cylinder 7Center Cylinder 11Lower Support StructureSupport Columns 2Beams 3Core Support Plate 13 Upper Guide StructureGrid Beams 1*Percent margin is computed as (Sallow - Scalc) (100%) / Sallow, where Scalc is thecalculated component stress and Sallow is the ASME Code allowable stress.
 
X/Q    (1) bounding X/Q values used for FHA, SLBOC and SFCD  (2) bounding X/Q values used for SGTR}}

Latest revision as of 03:03, 3 April 2019

Final Safety Analysis Report Update, Revision 32, Chapter 14 - Safety Analysis - Tables
ML16123A321
Person / Time
Site: Palisades Entergy icon.png
Issue date: 04/18/2016
From:
Entergy Nuclear Operations
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16120A302 List:
References
PNP 2016-015
Download: ML16123A321 (115)


Text

FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.11-3 Revision 32 Page 1 of 1

in

FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.14-7 Revision 28

Page 1 of 1

MAIN STEAM LINE BREAK (MSLB) RADIOLOGICAL ANALYSIS - INTACT SG STEAM RELEASE RATE

Time (hours) Intact SG Steam Release (lb m) 0 - 8 800,000 8 - 720.0 0

FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.15-8 Revision 28 Page 1 of 1 SGTR RADIOLOGICAL ANALYSIS - 40 CI/GM D.E. I-131 ACTIVITIES Isotope Activity Ci/gm) Iodine-131 33.2194 Iodine-132 7.6660 Iodine-133 34.4971 Iodine-134 3.0025 Iodine-135 14.6932

FSAR CHAPTER 14 - SAFETY ANALYSISTABLE 14.17.3-2Revision 30 Page 1 of 1ASYMMETRIC LOADS ANALYSIS - REACTOR VESSELINTERNAL COMPONENT STRESS MARGINSComponent LocationPercent Margin

(%)*Core Support BarrelUpper Flange 6Upper Cylinder 7Center Cylinder 11Lower Support StructureSupport Columns 2Beams 3Core Support Plate 13 Upper Guide StructureGrid Beams 1*Percent margin is computed as (Sallow - Scalc) (100%) / Sallow, where Scalc is thecalculated component stress and Sallow is the ASME Code allowable stress.

X/Q (1) bounding X/Q values used for FHA, SLBOC and SFCD (2) bounding X/Q values used for SGTR

FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.11-3 Revision 32 Page 1 of 1

in

FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.14-7 Revision 28

Page 1 of 1

MAIN STEAM LINE BREAK (MSLB) RADIOLOGICAL ANALYSIS - INTACT SG STEAM RELEASE RATE

Time (hours) Intact SG Steam Release (lb m) 0 - 8 800,000 8 - 720.0 0

FSAR CHAPTER 14 - SAFETY ANALYSIS TABLE 14.15-8 Revision 28 Page 1 of 1 SGTR RADIOLOGICAL ANALYSIS - 40 CI/GM D.E. I-131 ACTIVITIES Isotope Activity Ci/gm) Iodine-131 33.2194 Iodine-132 7.6660 Iodine-133 34.4971 Iodine-134 3.0025 Iodine-135 14.6932

FSAR CHAPTER 14 - SAFETY ANALYSISTABLE 14.17.3-2Revision 30 Page 1 of 1ASYMMETRIC LOADS ANALYSIS - REACTOR VESSELINTERNAL COMPONENT STRESS MARGINSComponent LocationPercent Margin

(%)*Core Support BarrelUpper Flange 6Upper Cylinder 7Center Cylinder 11Lower Support StructureSupport Columns 2Beams 3Core Support Plate 13 Upper Guide StructureGrid Beams 1*Percent margin is computed as (Sallow - Scalc) (100%) / Sallow, where Scalc is thecalculated component stress and Sallow is the ASME Code allowable stress.

X/Q (1) bounding X/Q values used for FHA, SLBOC and SFCD (2) bounding X/Q values used for SGTR