DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-1 Revision 36 OBE HORIZONTAL DESIGN GROUND RESPONSE SPECTRUM (HOUSNER)

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-2 Revision 36 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 4% DAMPING

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-3 Revision 36 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 72% DAMPING

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-4 Revision 36 CONTAINMENT BUILDING DYNAMIC MODEL

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-5 Revision 36 CONTAINMENT SHELL MAXIMUM SEISMIC RESPONSES (OBE)

COMPARISON OF RESPONSES FOR FIXED BASE AND COUPLED MODELS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-6 Revision 36 AUXILIARY BUILDING N-S MATHEMATICAL MODEL

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-7 Revision 36 AUXILIARY BUILDING E-W MATHEMATICAL MODEL

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-8 Revision 36 ELECTRICAL PENETRATION ENCLOSURE N-S & E-W DYNAMIC MODELS AND MAXIMUM SEISMIC RESPONSES (OBE)

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-9 Revision 36 TURBINE BUILDING E-W DYNAMIC MODELS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-10 Revision 36 TURBINE BUILDING E-W FUNDAMENTAL MODESHAPES, OUTSIDE WALLS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-11 Revision 36 TURBINE BUILDING E-W DIRECTION, MAXIMUM SEISMIC RESPONSES (SSE)

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-12 Revision 36 AUXILIARY BUILDING RADWASTE ADDITION DYNAMIC MODELS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-13 Revision 36 AUXILIARY BUILDING TSC/EER ADDITION DYNAMIC MODEL

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-14 Revision 36 AUXILIARY BUILDING TSC/EER ADDITION MAXIMUM SEISMIC RESPONSES (OBE)

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 1 Revision 36 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 2 Revision 36 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-2 Revision 36 CONTAINMENT STRUCTURE TYPICAL PIPING PENETRATIONS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-3 Revision 36 CONTAINMENT STRUCTURE TYPICAL ELECTRICAL PENETRATIONS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-4 Revision 36 CONTAINMENT STRUCTURE REINFORCING AND TENDON PLAN ADJACENT TO EQUIPMENT HATCH

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 1 Revision 36 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, SHOP BUTTONHEADED END

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 2 Revision 36 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, FIELD BUTTONHEADED END

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 3 Revision 36 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, SHOP BUTTONHEADED END

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 4 Revision 36 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, FIELD BUTTONHEADED END

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-6 Revision 36 CONTAINMENT STRUCTURE PERSONNEL AIR LOCK

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-7 Revision 36 CONTAINMENT STRUCTURE ESCAPE AIR LOCK

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-8 Revision 36 CONTAINMENT STRUCTURE EQUIPMENT HATCH DOOR

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-9 Revision 36 CONTAINMENT STRUCTURE FINITE ELEMENT MESH

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 1 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Fi

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 2 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.15P

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 3 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.5P + Ta

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 4 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + Ta

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 1 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Fi

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 2 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.15P

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 3 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.5 P + Ta

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 4 Revision 36 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + Ta

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 1 Revision 36 CONTAINMENT STRUCTURE STRESS RESULTANTS, DEAD LOAD (D)

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 2 Revision 36 CONTAINMENT STRUCTURE STRESS RESULTANTS, FINAL PRESTRESS (Ff)

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 3 Revision 36 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA PRESSURE (P)

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 4 Revision 36 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA TEMPERATURE (Ta)*

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-14 Revision 36 CONTAINMENT STRUCTURE FINITE ELEMENT MESH FOR BUTTRESS, PLANE STRAIN ANALYSIS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 1 Revision 36 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MAXIMUM COMPRESSIVE STRESSES

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 2 Revision 36 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MINIMUM COMPRESSIVE OR MAXIMUM TENSILE STRESSES

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 1 Revision 36 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 2 Revision 36 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-17 Revision 36 CONTAINMENT STRUCTURE RESULTS FROM TESTS ON LINER PLATE ANCHORS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-19 Revision 36 CONTAINMENT STRUCTURE LOADS ON PIPE PENETRATIONS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-20 Revision 36 CONTAINMENT STRUCTURE STRESS CONCENTRATIONS AT EQUIPMENT HATCH OPENING

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-21 Revision 36 CONTAINMENT STRUCTURE LINER PLATE, WELD CRACKING AT BACKING STRIP DISCONTINUITIES

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 1 Revision 36 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 113qq

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 2 Revision 36 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 275qq

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 1 Revision 36 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 583'-6"

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 2 Revision 36 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 588'-6"

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 3 Revision 36 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 590'-0"

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-29 Revision 36 CONSTRUCTION OPENING PLAN, ELEVATION AND SECTIONS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-30 Revision 36 CONSTRUCTION OPENING TENDON DETENSIONING AND POST TENSIONING SEQUENCE

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-31 Revision 36 MISCELLANEOUS GAS SUPPLY SYSTEMS

DSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.9-1 Revision 36 CONTAINMENT STRUCTURE INTERIOR CONSTRUCTION