DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-1, SHT 1 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIOACTIVE WASTE TREATMENT SYSTEM CLEAN

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-1, SHT 1A RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIOACTIVE WASTE TREATMENT SYSTEM CLEAN

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-1, SHT 1B RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIOACTIVE WASTE TREATMENT SYSTEM CLEAN

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-1, SHT 1C RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIOACTIVE WASTE TREATMENT SYSTEM CLEAN

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-1, SHT 2 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIOACTIVE WASTE TREATMENT SYSTEM CLEAN

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-1, SHT 3 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADWASTE EVAPORATOR SYSTEM CLEAN WASTES

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-2, SHT 1 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM DIRTY WASTE & GASEOUS WASTE

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-2, SHT 2 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADWASTE EVAPORATOR SYSTEM MICELLANEOUS WASTE

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-2, SHT 2A RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADWASTE EVAPORATOR SYSTEM MICELLANEOUS WASTE

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-2, SHT 2B RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADWASTE EVAPORATOR SYSTEM MICELLANEOUS WASTE

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-3 SHT 1 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIOACTIVE WASTE TREATMENT SYSTEM GASEOUS WASTE

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-3 SHT 2 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIOACTIVE WASTE TREATMENT SYSTEM GASEOUS WASTE

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-4 SHT 1 RADIATION PROTECTION Revision 36 SPENT RESIN STORAGE AND RADWASTE PACKAGING SYSTEM

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-4 SHT 2 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADWASTE SOLIDIFICATION SYSTEM

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-4 SHT 3 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM LIQUID VOLUME REDUCTION SYSTEM

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-5 SHT 1 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIATION MONITORING AND SAMPLING SYSTEMS

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-5 SHT 1A RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIATION MONITORING AND SAMPLING SYSTEMS

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-5 SHT 1B RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIATION MONITORING AND SAMPLING SYSTEMS

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-5 SHT 2 RADIATION PROTECTION Revision 36 PIPING AND INSTRUMENT DIAGRAM RADIATION MONITORING AND SAMPLING SYSTEMS

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-6 RADIATION PROTECTION Revision 36 GASEOUS EFFLUENT MONITORING SYSTEM

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-7 RADIATION PROTECTION Revision 36 ARCHITECTURAL ACCESS CONTROL AND RADIATION ZONING (PLANT IN OPERATION)

Portions of this page have been redacted per 10 CFR 2.390(d)(1).

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-8 RADIATION PROTECTION Revision 36 ARCHITECTURAL ACCESS CONTROL AND RADIATION ZONING (PLANT IN OPERATION)

Portions of this page have been redacted per 10 CFR 2.390(d)(1).

DSAR CHAPTER 11 - RADIOACTIVE WASTE MANAGEMENT AND FIGURE 11-9 RADIATION PROTECTION Revision 36 ARCHITECTURAL ACCESS CONTROL AND RADIATION ZONING (PLANT IN OPERATION)

Portions of this page have been redacted per 10 CFR 2.390(d)(1).