ML16120A415
| ML16120A415 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 04/18/2016 |
| From: | Entergy Nuclear Operations |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16120A302 | List:
|
| References | |
| PNP 2016-015 | |
| Download: ML16120A415 (66) | |
Text
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-1 Revision 21 OBE HORIZONTAL DESIGN GROUND RESPONSE SPECTRUM (HOUSNER)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-2 Revision 21 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 4% DAMPING
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-3 Revision 21 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 72% DAMPING
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-4 Revision 21 CONTAINMENT BUILDING DYNAMIC MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-5 Revision 21 CONTAINMENT SHELL MAXIMUM SEISMIC RESPONSES (OBE)
COMPARISON OF RESPONSES FOR FIXED BASE AND COUPLED MODELS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-6 Revision 21 AUXILIARY BUILDING N-S MATHEMATICAL MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-7 Revision 21 AUXILIARY BUILDING E-W MATHEMATICAL MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-8 Revision 21 ELECTRICAL PENETRATION ENCLOSURE N-S & E-W DYNAMIC MODELS AND MAXIMUM SEISMIC RESPONSES (OBE)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-9 Revision 21 TURBINE BUILDING E-W DYNAMIC MODELS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-10 Revision 21 TURBINE BUILDING E-W FUNDAMENTAL MODESHAPES, OUTSIDE WALLS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-11 Revision 21 TURBINE BUILDING E-W DIRECTION, MAXIMUM SEISMIC RESPONSES (SSE)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-12 Revision 21 AUXILIARY BUILDING RADWASTE ADDITION DYNAMIC MODELS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-13 Revision 21 AUXILIARY BUILDING TSC/EER ADDITION DYNAMIC MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-14 Revision 21 AUXILIARY BUILDING TSC/EER ADDITION MAXIMUM SEISMIC RESPONSES (OBE)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 1 Revision 21 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 2 Revision 21 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-2 Revision 21 CONTAINMENT STRUCTURE TYPICAL PIPING PENETRATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-3 Revision 21 CONTAINMENT STRUCTURE TYPICAL ELECTRICAL PENETRATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-4 Revision 21 CONTAINMENT STRUCTURE REINFORCING AND TENDON PLAN ADJACENT TO EQUIPMENT HATCH
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 1 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, SHOP BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 2 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, FIELD BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 3 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, SHOP BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 4 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, FIELD BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-6 Revision 21 CONTAINMENT STRUCTURE PERSONNEL AIR LOCK
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-7 Revision 21 CONTAINMENT STRUCTURE ESCAPE AIR LOCK
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-8 Revision 21 CONTAINMENT STRUCTURE EQUIPMENT HATCH DOOR
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-9 Revision 21 CONTAINMENT STRUCTURE FINITE ELEMENT MESH
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-10 Revision 21 CONTAINMENT STRUCTURE DBA THERMAL GRADIENTS ACROSS CONTAINMENT WALL, NO INSULATION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 1 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Fi
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 2 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.15P
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 3 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.5P + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 4 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 1 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Fi
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 2 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.15P
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 3 Revision 22 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.5 P + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 4 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 1 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, DEAD LOAD (D)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 2 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, FINAL PRESTRESS (Ff)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 3 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA PRESSURE (P)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 4 Revision 22 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA TEMPERATURE (Ta)*
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-14 Revision 21 CONTAINMENT STRUCTURE FINITE ELEMENT MESH FOR BUTTRESS, PLANE STRAIN ANALYSIS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 1 Revision 21 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MAXIMUM COMPRESSIVE STRESSES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 2 Revision 21 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MINIMUM COMPRESSIVE OR MAXIMUM TENSILE STRESSES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 1 Revision 21 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 2 Revision 21 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-17 Revision 21 CONTAINMENT STRUCTURE RESULTS FROM TESTS ON LINER PLATE ANCHORS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-18 Revision 21 CONTAINMENT STRUCTURE THERMAL GRADIENT AT MAIN STEAM PENETRATION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-19 Revision 21 CONTAINMENT STRUCTURE LOADS ON PIPE PENETRATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-20 Revision 21 CONTAINMENT STRUCTURE STRESS CONCENTRATIONS AT EQUIPMENT HATCH OPENING
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-21 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, WELD CRACKING AT BACKING STRIP DISCONTINUITIES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 1 Revision 21 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 113°
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 2 Revision 21 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 275°
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 1 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 583'-6"
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 2 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 588'-6"
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 3 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 590'-0"
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-24 Revision 21 CONTAINMENT STRUCTURE LOCATION AND IDENTIFICATION OF ELEVEN SURVEILLANCE TENDONS FOR ONE-AND THREE-YEAR SURVEILLANCES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-25, SHT 1 Revision 21 CONTAINMENT STRUCTURE STRUCTURAL INTEGRITY TEST INSIDE HOOP STRAIN PROFILES TYPICAL SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-25, SHT 2 Revision 21 CONTAINMENT STRUCTURE STRUCTURAL INTEGRITY TEST OUTSIDE MERIDIONAL STRAIN PROFILES TYPICAL SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-26 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST DISPLACEMENT PROFILES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-27, SHT 1 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST TENDON LOAD CHANGE
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-27, SHT 2 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST TENDON LOAD CHANGE
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-28 Revision 21 CONTAINMENT STRUCTURE END ANCHORAGE SURVEILLANCE PROGRAM CRACK SURVEILLANCE LOCATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-29 Revision 21 CONSTRUCTION OPENING PLAN, ELEVATION AND SECTIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-30 Revision 21 CONSTRUCTION OPENING TENDON DETENSIONING AND POST TENSIONING SEQUENCE
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-31 Revision 32 MISCELLANEOUS GAS SUPPLY SYSTEMS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.9-1 Revision 21 CONTAINMENT STRUCTURE INTERIOR CONSTRUCTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-1 Revision 21 OBE HORIZONTAL DESIGN GROUND RESPONSE SPECTRUM (HOUSNER)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-2 Revision 21 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 4% DAMPING
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-3 Revision 21 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 72% DAMPING
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-4 Revision 21 CONTAINMENT BUILDING DYNAMIC MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-5 Revision 21 CONTAINMENT SHELL MAXIMUM SEISMIC RESPONSES (OBE)
COMPARISON OF RESPONSES FOR FIXED BASE AND COUPLED MODELS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-6 Revision 21 AUXILIARY BUILDING N-S MATHEMATICAL MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-7 Revision 21 AUXILIARY BUILDING E-W MATHEMATICAL MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-8 Revision 21 ELECTRICAL PENETRATION ENCLOSURE N-S & E-W DYNAMIC MODELS AND MAXIMUM SEISMIC RESPONSES (OBE)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-9 Revision 21 TURBINE BUILDING E-W DYNAMIC MODELS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-10 Revision 21 TURBINE BUILDING E-W FUNDAMENTAL MODESHAPES, OUTSIDE WALLS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-11 Revision 21 TURBINE BUILDING E-W DIRECTION, MAXIMUM SEISMIC RESPONSES (SSE)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-12 Revision 21 AUXILIARY BUILDING RADWASTE ADDITION DYNAMIC MODELS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-13 Revision 21 AUXILIARY BUILDING TSC/EER ADDITION DYNAMIC MODEL
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-14 Revision 21 AUXILIARY BUILDING TSC/EER ADDITION MAXIMUM SEISMIC RESPONSES (OBE)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 1 Revision 21 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 2 Revision 21 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-2 Revision 21 CONTAINMENT STRUCTURE TYPICAL PIPING PENETRATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-3 Revision 21 CONTAINMENT STRUCTURE TYPICAL ELECTRICAL PENETRATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-4 Revision 21 CONTAINMENT STRUCTURE REINFORCING AND TENDON PLAN ADJACENT TO EQUIPMENT HATCH
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 1 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, SHOP BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 2 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, FIELD BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 3 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, SHOP BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 4 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, FIELD BUTTONHEADED END
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-6 Revision 21 CONTAINMENT STRUCTURE PERSONNEL AIR LOCK
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-7 Revision 21 CONTAINMENT STRUCTURE ESCAPE AIR LOCK
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-8 Revision 21 CONTAINMENT STRUCTURE EQUIPMENT HATCH DOOR
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-9 Revision 21 CONTAINMENT STRUCTURE FINITE ELEMENT MESH
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-10 Revision 21 CONTAINMENT STRUCTURE DBA THERMAL GRADIENTS ACROSS CONTAINMENT WALL, NO INSULATION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 1 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Fi
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 2 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.15P
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 3 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.5P + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 4 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 1 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Fi
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 2 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.15P
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 3 Revision 22 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.5 P + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 4 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + Ta
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 1 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, DEAD LOAD (D)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 2 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, FINAL PRESTRESS (Ff)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 3 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA PRESSURE (P)
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 4 Revision 22 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA TEMPERATURE (Ta)*
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-14 Revision 21 CONTAINMENT STRUCTURE FINITE ELEMENT MESH FOR BUTTRESS, PLANE STRAIN ANALYSIS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 1 Revision 21 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MAXIMUM COMPRESSIVE STRESSES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 2 Revision 21 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MINIMUM COMPRESSIVE OR MAXIMUM TENSILE STRESSES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 1 Revision 21 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 2 Revision 21 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-17 Revision 21 CONTAINMENT STRUCTURE RESULTS FROM TESTS ON LINER PLATE ANCHORS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-18 Revision 21 CONTAINMENT STRUCTURE THERMAL GRADIENT AT MAIN STEAM PENETRATION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-19 Revision 21 CONTAINMENT STRUCTURE LOADS ON PIPE PENETRATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-20 Revision 21 CONTAINMENT STRUCTURE STRESS CONCENTRATIONS AT EQUIPMENT HATCH OPENING
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-21 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, WELD CRACKING AT BACKING STRIP DISCONTINUITIES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 1 Revision 21 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 113°
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 2 Revision 21 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 275°
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 1 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 583'-6"
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 2 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 588'-6"
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 3 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 590'-0"
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-24 Revision 21 CONTAINMENT STRUCTURE LOCATION AND IDENTIFICATION OF ELEVEN SURVEILLANCE TENDONS FOR ONE-AND THREE-YEAR SURVEILLANCES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-25, SHT 1 Revision 21 CONTAINMENT STRUCTURE STRUCTURAL INTEGRITY TEST INSIDE HOOP STRAIN PROFILES TYPICAL SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-25, SHT 2 Revision 21 CONTAINMENT STRUCTURE STRUCTURAL INTEGRITY TEST OUTSIDE MERIDIONAL STRAIN PROFILES TYPICAL SECTION
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-26 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST DISPLACEMENT PROFILES
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-27, SHT 1 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST TENDON LOAD CHANGE
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-27, SHT 2 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST TENDON LOAD CHANGE
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-28 Revision 21 CONTAINMENT STRUCTURE END ANCHORAGE SURVEILLANCE PROGRAM CRACK SURVEILLANCE LOCATIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-29 Revision 21 CONSTRUCTION OPENING PLAN, ELEVATION AND SECTIONS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-30 Revision 21 CONSTRUCTION OPENING TENDON DETENSIONING AND POST TENSIONING SEQUENCE
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-31 Revision 32 MISCELLANEOUS GAS SUPPLY SYSTEMS
FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.9-1 Revision 21 CONTAINMENT STRUCTURE INTERIOR CONSTRUCTION