6 to Updated Final Safety Analysis Report, Chapter 8, Figures
ML23107A029
Person / Time
Site: Palisades 
(DPR-020)
Issue date: 03/31/2023
From:
Holtec Decommissioning International
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23107A065 List: ... further results
References
HDI PNP 2023-002
Download: ML23107A029 (1)


Text

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-1, SHT 1 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 480 VOLT MOTOR CONTROL CENTER - WAREHOUSE

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-1, SHT 2 Revision 36 PLANT SINGLE LINE DIAGRAM

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-1, SHT 3 Revision 36 PLANT SINGLE LINE DIAGRAM

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-2 Revision 36 SUBSTATION

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-3, SHT 1 Revision 36 SINGLE LINE METER & RELAY DIAGRAM GENERATOR & 4160V SYSTEM

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-3, SHT 2 Revision 36 SINGLE LINE METER & RELAY DIAGRAM COOLING TOWER SYSTEMS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-4 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 2400 VOLT SYSTEM

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-5, SHT 1 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 480 VOLT LOAD CENTERS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-5, SHT 2 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 480 VOLT LOAD CENTERS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-5, SHT 3 Revision 36 SINGLE LINE METER & RELAY DIAGRAM COOLING TOWER SYSTEMS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-6, SHT 1 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 480 VOLT MOTOR CONTROL CENTERS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-6, SHT 2 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 480 VOLT MOTOR CONTROL CENTERS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-6, SHT 3 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 480 VOLT MOTOR CONTROL CENTERS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-6, SHT 4 Revision 36 SINGLE LINE METER & RELAY DIAGRAM RADWASTE SYSTEM

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-7, SHT 1 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 125V DC, 120V INSTRUMENT & PREFERRED AC SYSTEM

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-7, SHT 2 Revision 36 SINGLE LINE METER & RELAY DIAGRAM 125V DC, 120V INSTRUMENT & PREFERRED AC SYSTEM

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-8 Revision 36 125 V DC SYSTEM AUXILIARY SHUTDOWN LAYOUT

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-9 Revision 36 SUBSTATION 120/240V AC & 125V DC POWER DISTRIBUTION CENTER

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-10 Revision 36 VOLTAGE PROTECTION SENSORS LOCATION

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-11 Revision 36 PIPING & INSTRUMENT DIAGRAM LUBE OIL, FUEL OIL AND DIESEL GENERATOR SYSTEMS

DSAR CHAPTER 8 - ELECTRICAL SYSTEMS FIGURE 8-12 Revision 36 BATTERY SUPPLY FOR ALTERNATE CONTROLS CREDITED IN FIRE SCENARIOS