ML17151B057: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 14: | Line 14: | ||
| document type = Fire Protection Plan | | document type = Fire Protection Plan | ||
| page count = 2 | | page count = 2 | ||
}} | }} | ||
=Text= | |||
{{#Wiki_filter:Form APF-05-003-01, Rev. 2 A ' ASSIGNED DISCIPLINE: | |||
Mechanical DESIGN DOCUMENT CHANGE NOTICE DOCUMENT NUMBER M-663-00017 A OTHER DOCUMENTS AFFECTED BY THIS CHANGE: NONE OTHER DDCN'S REQUIRED TO IMPLEMENT CHANGE: NONE REASON FOR CHANGE: Incorporate changes per CCP 14714. Cable tray 115U5A94 now contains a PFSSD cable so clarification is needed since this cable tray is in the heat affected zone for some penetrations. | |||
PREPARED BY: DATE: 11/20/2014 Verifier Qualification will be to the same requirement as the parent document VERIFIED BY: APPROVED BY: DC RELEASE: DESCRIPTION OF CHANGE: 02/07/2015 DATE: DATE: 02/19/2015 Kay L Smith Released by Document Services. | |||
Release Date: 2015.03.26 08:23:46 -05'00' On page B 13-66 ofB 13-88, make the following changes: Fire Area (Side 1) A-16 INITIATING DOC. TYPE: N/A NO. N/A DCP/CCP NO 14714 REV. 0 REV. W05 SEQ. NO. 01 PAGE I OF 2 | |||
.. I R | |||
# <1:1, P'-'" . f:: | |||
0_1.. | |||
\ . ;:.:: . -. : g*s i-11\ ) 6 '::'! 7l . _.:P,:;,:::. ** .. /t;qNsf'-'3 | |||
.* * | |||
* of ...... | |||
'IONAL 111 11111111111111\111\\\ | |||
Digitally signed by Brian R Fox Date: 2015.02.20 08:21:36 -06'00' RPE Certification For ASME Section III design specifications, refer to AP 05-004 for qualification requirements I. 24" Cable Tray 5U5A94 is within Heat Affected Zone. Further review determined that this cable tray is PFSSD. Document E-IF9910 provides the basis for acceptance. | |||
Fire Area (Side 2) A-5 1. 24" Cable Tray 5U5A94 is within Heat Affected Zone. Further review determined that this cable tray is PFSSD. Document E-IF9910 provides the basis for acceptance. | |||
.---------------------------------------------------- | |||
------Form APF-05-003-01, Rev. 0 i_ ' ASSIGNED DISCIPLINE: | |||
Mechanical DESIGN DOCUMENT CHANGE NOTICE DOCUMENT NUMBER M-663-00017A On page B 13-69 ofB 13-88, make the following changes: Fire Area (Side 1) A-16 INITIATING DOC. TYPE: N/A NO. N/A DCP/CCP NO 14714 REV. 0 REV. wos SEQ. NO. 01 PAGE 2 OF 2 1. 24" Cable Tray 5U5A94 is within Heat Affected Zone (1/2" clearance to pipe strut clamp). Further review determined that this cable tray is PFSSD. Document E-1F991 0 provides the basis for acceptance. | |||
Fire Area (Side 2) A-5 1. 24" Cable Tray 5U5A94 is within Heat Affected Zone (3-1/2"). | |||
Further review determined that this cable tray is PFSSD. Document E-1F9910 provides the basis for acceptance.}} |
Latest revision as of 21:13, 7 July 2018
ML17151B057 | |
Person / Time | |
---|---|
Site: | Wolf Creek ![]() |
Issue date: | 03/09/2017 |
From: | Wolf Creek |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML17151A982 | List:
|
References | |
WO 17-0045 | |
Download: ML17151B057 (2) | |
Text
Form APF-05-003-01, Rev. 2 A ' ASSIGNED DISCIPLINE:
Mechanical DESIGN DOCUMENT CHANGE NOTICE DOCUMENT NUMBER M-663-00017 A OTHER DOCUMENTS AFFECTED BY THIS CHANGE: NONE OTHER DDCN'S REQUIRED TO IMPLEMENT CHANGE: NONE REASON FOR CHANGE: Incorporate changes per CCP 14714. Cable tray 115U5A94 now contains a PFSSD cable so clarification is needed since this cable tray is in the heat affected zone for some penetrations.
PREPARED BY: DATE: 11/20/2014 Verifier Qualification will be to the same requirement as the parent document VERIFIED BY: APPROVED BY: DC RELEASE: DESCRIPTION OF CHANGE: 02/07/2015 DATE: DATE: 02/19/2015 Kay L Smith Released by Document Services.
Release Date: 2015.03.26 08:23:46 -05'00' On page B 13-66 ofB 13-88, make the following changes: Fire Area (Side 1) A-16 INITIATING DOC. TYPE: N/A NO. N/A DCP/CCP NO 14714 REV. 0 REV. W05 SEQ. NO. 01 PAGE I OF 2
.. I R
- <1:1, P'-'" . f::
0_1..
\ . ;:.:: . -. : g*s i-11\ ) 6 '::'! 7l . _.:P,:;,:::. ** .. /t;qNsf'-'3
.* *
- of ......
'IONAL 111 11111111111111\111\\\
Digitally signed by Brian R Fox Date: 2015.02.20 08:21:36 -06'00' RPE Certification For ASME Section III design specifications, refer to AP 05-004 for qualification requirements I. 24" Cable Tray 5U5A94 is within Heat Affected Zone. Further review determined that this cable tray is PFSSD. Document E-IF9910 provides the basis for acceptance.
Fire Area (Side 2) A-5 1. 24" Cable Tray 5U5A94 is within Heat Affected Zone. Further review determined that this cable tray is PFSSD. Document E-IF9910 provides the basis for acceptance.
.----------------------------------------------------
Form APF-05-003-01, Rev. 0 i_ ' ASSIGNED DISCIPLINE:
Mechanical DESIGN DOCUMENT CHANGE NOTICE DOCUMENT NUMBER M-663-00017A On page B 13-69 ofB 13-88, make the following changes: Fire Area (Side 1) A-16 INITIATING DOC. TYPE: N/A NO. N/A DCP/CCP NO 14714 REV. 0 REV. wos SEQ. NO. 01 PAGE 2 OF 2 1. 24" Cable Tray 5U5A94 is within Heat Affected Zone (1/2" clearance to pipe strut clamp). Further review determined that this cable tray is PFSSD. Document E-1F991 0 provides the basis for acceptance.
Fire Area (Side 2) A-5 1. 24" Cable Tray 5U5A94 is within Heat Affected Zone (3-1/2").
Further review determined that this cable tray is PFSSD. Document E-1F9910 provides the basis for acceptance.