FORM APF-05D-001-02, REV. 12 Page 1 CALCULATION CHANGE NOTICE CCN NO. XX-E-013 - 004 - CN008 Base Calc No. Rev No. Sequence No.

CALCULATION TITLE - From CALCULATION TITLE field in EIS:

POST-FIRE SAFE SHUTDOWN (PFSSD) ANALYSIS COMPUTER CODE: N/A VERSION: N/A Administrative? YES NO ASSOCIATED ENGINEERING CHANGE #: 13324 REGULATORY Attached Evaluation #

REVIEWS:

Attached to: 13324 Not Applicable N/A Only if Administrative USAR STATEMENT: Requires a change to the USAR:

Does NOT require a change to the USAR ANY DOCUMENTS YES If yes, enter: SWO #, or Condition Report #, if applicable.

IMPACTED?

NO Status: COMMITTED FINAL VOID SUPERSEDED DigsigOrg 2.8, 0.7 ORIG Brian Fox 7/22/2020 ORIG Printed Name Printed Name Date Date Brian R. Fox 2020.07.22 16:21:31 -05'00' Signature Signature QUALIFICATION REQUIRED: ES9280479 QUALIFICATION REQUIRED: ES9280479 DigsigVer 2.8, 0.7 VERF William Wilkins 07/22/2020 VERF Printed Name Date Printed Name Date Jitesh K. Patel Digitally signed by Jitesh K. Patel Date: 2021.08.18 10:18:12 -05'00' Signature Signature ES9280479 QUALIFICATION REQUIRED: ES9280479 QUALIFICATION REQUIRED:

DigsigApp 2.8, 0.7 APP Jeff Suter 07/22/2020 APP Printed Name Date Printed Name Date Digitally signed by Jeff Suter Jeff Suter Date: 2021.08.18 11:52:52

-05'00' Signature Signature DigsigCert 3.5 1.75 DigsigCert 3.5 1.75 Digitally signed by Brian R. Fox Date:

2020.07.22 16:24:40 -05'00' RPE Certification (For ASME Section III Stress Reports/Design Reports, refer to AP 05D-001 for qualification requirements)

CALCULATION SUBJECT (Statement Of Problem) - Enter this in SUBJECT field in EIS:

CP 13324 will replace the 7300 Controls System with a new Ovation DCS components. Changes in PFSSD functional descriptions and components are updated to reflect this change.

FORM APF-05D-001-02, REV. 12 Page 2 CALCULATION DATABASE INPUT CCN NO. XX-E-013 - 004 - 008 Base Calc No. Rev No. Sequence No.

Link new systems to the calculation/CCN in EIS.

Systems BB, PG, PK, PN, RP Affected:

Develop relationships between interdependent calculations in EIS.

Additional None Calculations Providing Input to this calculation:

Additional None Calculations Impacted by this calculation:

Develop relationships between the calculation/CCN and controlled reference documents in EIS.

Additional M-761A-00019, M-761A-00025, E-13PN02, E-11PK01, E-11PK04 Controlled Documents Inputs to this calculation:

Additional None Controlled Documents Impacted by this calculation:

The reference documents listed below are those that cannot be linked to the calculation/CCN and shall be entered in the INDUSTRY REFERENCE field in EIS, e.g., ASME Codes, ANSI Standards, letters, etc.

Additional CP 13324, CP 20011 Other Reference Documents:

Link new components to the calculation/CCN in EIS.

Additional NG0410, PG19GCF3, PG20GAF4, PK004, PK014, PK024, PK0105, PK0401, Components: PK0402, PK0407, PN003, PN004, PN310, PN410 (remove BBPK0455A, BBPK0455B, BBPK0455C, BBPS0455F, PG19GAF1, PG20GAF2, PK42, PK4200, PK4207, PK6107, PN001, PN002)

REFER TO DESKTOP GUIDE FOR PROCESSING CALCULATIONS IN EIS

FORM APF-05D-001-02, REV. 12 Page 3 LIST OF EFFECTIVE PAGES CCN NO. XX-E-013 - 004 - 008 Base Calc No. Rev No. Sequence No.

CCN Calc. CCN Calc. CCN Calc. CCN Calc.

Page Page Page Page Page Page Page Page No.

Affected No. Affected No. Affected No. Affected DVR/SCRN/ /DVR/SCRN /DVR/SCRN /DVR/SCRN Other /Other /Other /Other 1-5 N/A Att. 1 App. 1 p20-22 App. 3 p28-31, 35, 90, 108-115, 117-118 DVR = Design Verification Report (if applicable)

SCRN = Regulatory Screening (if applicable)

AD = Applicability Determination

FORM APF-05D-001-02, REV. 12 Page 4 CALCULATION SHEET CCN NO. XX-E-013 - 004 - 008 Base Calc. No. Rev. No. Sequence No CP 13324 replaces the analog based Westinghouse 7300 Nuclear Steam Supply System (NSSS) with a digital Emerson Ovation Distributed Control System (DCS). The change impacts the PFSSD analysis.

Changes to Calculation XX-E-013 are included in this CCN. Markups are attached.

Calculation Appendix 1 Page 20 Revise per attached markup to describe the operation of the pressurizer PORV controls.

Calculation Appendix 1 Pages 21 and 22 Revise per attached markup to describe the operation of the normal spray valves.

Calculation Appendix 1 Page 22 Revise per attached markup to describe that the PFSSD design of the pressurizer heaters is not affected.

Calculation Appendix 3 Revise per the attached markup.

FORM APF-05D-001-02, REV. 12 Page 5 ATTACHMENT 1 CCN NO. XX-E-013 - 004 - 008 Page 1 of 20 Base Calc No. Rev No. Sequence No Attachment 1 - XX-E-013 markup

CCN XX-E-013-004-CN008 Attachment 1 Page 2 of 20

)250$3)'5(9

APPENDIX 1 CALCULATION NO. XX-E-013 PFSSD FUNCTION EVALUATIONS REVISION NO. 4 (REACTOR MAKEUP) Page 20 5(/$< '(6&5,37,21 &200(17

;%% 3UHVVXUL]HU3259%ORFN9DOYH ,IUHOD\HQHUJL]HG%%+9$ZLOORSHQ

%%+9$$X[LOLDU\5HOD\

;%% 3UHVVXUL]HU3259%ORFN9DOYH ,IUHOD\HQHUJL]HG%%+9%ZLOORSHQ

%%+9%$X[LOLDU\5HOD\

. 3UHVVXUL]HU+LJK3UHVVXUH7UDLQ$ ,IUHOD\HQHUJL]HG%%3&9$ZLOORSHQ

. 3UHVVXUL]HU+LJK3UHVVXUH7UDLQ% ,IUHOD\HQHUJL]HG%%3&9$ZLOORSHQ

%% 3UHVVXUL]HU3259%%3&9$ 7ZR$X[LOLDU\UHOD\FRQWDFWVLQVHULHVPXVW

&RQWDFWRU3DQHO EHFORVHGWRLQLWLDWHFORVLQJIRXUFRQWDFWVLQ

VHULHVWRRSHQ%%3&9$

7KH 2YDWLRQ V\VWHP XVHV VLJQDO YHULILFDWLRQ IURP DOO IRXU SUHVVXUL]HU SUHVVXUH FKDQQHOV ZLWK WKH QG KLJKHVW SUHVVXUH LQSXW

%% VLJQDO

VHOHFWHG DV WKH YDOLGDWHG 3UHVVXUL]HU3259%%3&9$

7ZR VHSDUDWH IRXUFKDQQHO VLJQDO VHOHFWLRQ 7ZR$X[LOLDU\UHOD\FRQWDFWVLQVHULHVPXVW

VFKHPHV LQ VHSDUDWH 2YDWLRQ GURSV DUH XVHG WR

&RQWDFWRU3DQHO GHYHORS WKH DFWXDWLRQ VLJQDOV IRU WKH 3259V RQH IRU %%3&9$ DQG RQH EHFORVHGWRLQLWLDWHFORVLQJIRXUFRQWDFWVLQ

IRU %%3&9$ $ KRW VKRUW RSHQ FLUFXLW RU VHULHVWRRSHQ%%3&9$

VKRUW WR JURXQG RQ D VLQJOH LQSXW FKDQQHO ZLOO UHVXOW LQ WKH VLJQDO IDLOLQJ HLWKHU KLJK RU ORZ ,I LW IDLOV WR WKH ORZHVW VHWWLQJ WKHUH LV QR LPSDFW RQ 3)66' EHFDXVH WKH 3259V ZLOO UHPDLQ FORVHG ,I LW IDLOV WR WKH KLJKHVW VHWWLQJ WKHUH LV QR LPSDFW EHFDXVH WKH 2YDWLRQ V\VWHP7KHIROORZLQJFRPSRQHQWVDQGVLJQDOVDUHUHODWHGWRFROGRYHUSUHVVXUHSURWHFWLRQDQGQRWUHTXLUHGIRUSRVWILUH

ZLOO FRQWLQXH WR XVH WKH QG KLJKHVW LQSXW ,I WKH 2YDWLRQ V\VWHP VHQVHV D IDLOHG LQSXW WKH FRQWURO ORJLF ZLOO FKDQJH IURP QG KLJKHVW WR DQ DYHUDJH RI WKH WZR KLJKHVW LQSXWV 3259 %%3&9$ RSHQV ZKHQ YDOLGDWHG SUHVVXUH HTXDOV VDIHVKXWGRZQ%%+6$%%+6%%%=$%%=$$%%=$$%%=6$

RU H[FHHGV %%=6$%%3%&%%39&%%3%(DQG%%3%(

SVLJ RYHU VHWSRLQW  SVLJ DQG FORVHV ZKHQ SUHVVXUH UHWXUQV WR  SVLJ RYHU VHWSRLQW 3259

%%3&9$ RSHQV ZKHQ WKH YDOLGDWHG SUHVVXUH H[FHHGV  SVLJ DQG FORVHV ZKHQ SUHVVXUH UHGXFHV WR  SVLJ

)LUH GDPDJH WR7KHSUHVVXUL]HUSUHVVXUHUHOLHIVLJQDOVIURPWKHVROLGVWDWHSURWHFWLRQV\VWHP

WZR RU PRUH LQSXW FKDQQHOV ZRXOG KDYH WR RFFXU DW WKH H[DFW VDPH WLPH DQG IDLO 6636WR WKH H[DFW VDPH YDOXH EXW

DUHLQFOXGHGLQWKHSRVW

QRW H[FHHG WKHILUHVDIHVKXWGRZQGHVLJQ7KHUHDVRQIRULQFOXGLQJWKHVHVLJQDOVLVWKDWLQDGYHUWDQWRSHUDWLRQRIWKHSUHVVXUH

PD[LPXP 9 YDOXH LQ RUGHU IRU WKH 2YDWLRQ V\VWHP WR FRQVLGHU WKHP YDOLG DQG VLJQDO WKH 3259V WR RSHQ

FRQWUROV\VWHPFRXOGFRPSOLFDWH3)66'E\FDXVLQJWKHSUHVVXUL]HU3259VDQGVSUD\YDOYHVWRRSHUDWHWKXV

7KLV LV QRW FRQVLGHUHG D FUHGLEOH VFHQDULR DQG LV QRW FRQVLGHUHG SRVVLEOH LQ WKH ILUH DUHD DQDO\VLV

FDXVLQJDUDSLGGHFUHDVHLQ5&6SUHVVXUHZKLFKFRXOGOHDGWRERLOLQJLQWKHFRUH

)RXUSUHVVXUL]HUSUHVVXUHWUDQVPLWWHUVIHHGVLJQDOVWRWKHSUHVVXUL]HUSUHVVXUHDQGOHYHOFRQWUROV\VWHPDV

ZHOODVWKHUHDFWRUSURWHFWLRQV\VWHP 536 7KHVLJQDOVIURPWKHSUHVVXUHWUDQVPLWWHUVSHUIRUPWKHIROORZLQJ

IXQFWLRQVDSSOLFDEOHWR3)66'

x 7ULSVWKHUHDFWRURQ RIKLJKSUHVVXUHDWSVLJ ŽWsŽ

x &ORVHV3259EORFNYDOYHVRQRIORZSUHVVXUHDWSVLJ x 7ULSVWKHUHDFWRURQRIORZSUHVVXUHDWSVLJ x 6DIHW\LQMHFWLRQRQRIORZSUHVVXUHDWSVLJ ŽŽ

x 2SHQV3259%%3&9$RQVLJQDOIURPWKHSUHVVXUL]HUSUHVVXUHPDVWHUFRQWUROOHU %%3.$ 

7KHQRPLQDORSHQVHWSRLQWLVSVLJIURPHLWKHU%%37RU%%37GHSHQGLQJRQWKH

SRVLWLRQRIWKHSUHVVXUHFKDQQHOVHOHFWRUVZLWFK %%36) 7KHQRUPDOVZLWFKSRVLWLRQLVZLWK

%%37VHOHFWHG

x 2SHQV3259%%3&9$RQVLJQDOIURPSUHVVXUL]HUSUHVVXUHFRQWUROV\VWHPWKURXJKDELVWDEOHVHW

DWSVLJIURPHLWKHU%%37RU%%37GHSHQGLQJRQWKHSRVLWLRQRIWKHSUHVVXUHFKDQQHO

VHOHFWRUVZLWFK %%36) 7KHQRUPDOVZLWFKSRVLWLRQLVZLWK%%37VHOHFWHG

7KHUHDFWRUWULSVLJQDOVDQGEORFNYDOYHFORVHVLJQDOVDUHQRWVSHFLILFDOO\GLVFXVVHGLQWKHILUHDUHDDQDO\VHV

EHFDXVHZLWKWKHUHDFWRUWULSSHGDQGWKHEORFNYDOYHVFORVHGWKHGHVLUHG3)66'FRQGLWLRQLVDFKLHYHG$

VSXULRXVVDIHW\LQMHFWLRQVLJQDO 6,6 FRPSOLFDWHV3)66'VRWKHILUHDUHDDQDO\VLVGRFXPHQW () 

DGGUHVVHVDUHDVZKHUHVSXULRXVORZSUHVVXUL]HUSUHVVXUH6,6FDQRFFXU6SXULRXVVLJQDOVIURPWKH

CCN XX-E-013-004-CN008 Attachment 1 Page 3 of 20

)250$3)'5(9

APPENDIX 1 CALCULATION NO. XX-E-013 PFSSD FUNCTION EVALUATIONS REVISION NO. 4 (REACTOR MAKEUP) Page 21 SUHVVXUL]HUSUHVVXUHFRQWUROV\VWHPFRXOGFDXVHRQHRUERWKSUHVVXUL]HU3259VWRRSHQZKLFKLVQRWGHVLUHG

IRU3)66'7KHUHIRUHWKHVHSUHVVXUHVLJQDOVDUHHYDOXDWHGLQWKHILUHDUHDDQDO\VLVGRFXPHQW () 

 5&6&RROGRZQ5DWH&RQWURO5&6FRROGRZQUDWHFRQWUROLQFOXGHVSUHYHQWLRQRIXQFRQWUROOHG5&6FRROGRZQ

DQGFRQWUROOLQJ 5&6FRROGRZQUDWHGXULQJGHFD\KHDWUHPRYDO

D 8QFRQWUROOHG5&6&RROGRZQ0DLQVWHDPFRPSRQHQWVWKDWFRXOGLQLWLDWHXQFRQWUROOHG5&6FRROGRZQDUH

FRQWUROOHG LVRODWHG &RQWURORIWKHVHPDLQVWHDPFRPSRQHQWV VWHDPJHQHUDWRUDWPRVSKHULFUHOLHIYDOYHV

06,9VDQG06,9E\SDVVYDOYHV LVGHVFULEHGLQWKHUHDFWLYLW\FRQWUROIXQFWLRQGLVFXVVLRQ

E &RQWURORI5&6&RROGRZQ5DWH0DLQVWHDPFRPSRQHQWV VWHDPJHQHUDWRUDWPRVSKHULFUHOLHIYDOYHV XVHG

WRFRQWURO5&6FRROGRZQDUHGHVFULEHGLQWKHGHFD\KHDWUHPRYDOIXQFWLRQGLVFXVVLRQ

0DLQVWHDPOLQHSUHVVXUHWUDQVPLWWHUVSURYLGHDVWHDPOLQHSUHVVXUHLQSXWVLJQDOWRWKHVDIHW\LQMHFWLRQFLUFXLWV

6DIHW\LQMHFWLRQFRPSOLFDWHVFRQWURORIWKHUHDFWLYLW\FRQWUROIXQFWLRQ H[FHVVLYHFRROGRZQLQVHUWVSRVLWLYH

UHDFWLYLW\ UHDFWRUPDNHXSIXQFWLRQ SUHVVXUL]HUOHYHOPD\QRWEHPDLQWDLQHGZLWKLQLQGLFDWLQJUDQJH DQGGHFD\

KHDWUHPRYDO H[FHVVLYHFRROGRZQUDWH 6DIHW\LQMHFWLRQLVFRQWUROOHGE\HLWKHUSUHYHQWLQJVDIHW\LQMHFWLRQ

DFWXDWLRQ SURWHFWLQJ6,LQSXWVLJQDOVDQGRURSHQLQJVDIHW\LQMHFWLRQSXPSEUHDNHUVWRSUHYHQWVDIHW\LQMHFWLRQ

SXPSVIURPUXQQLQJ &RQVHTXHQWO\WKHIROORZLQJVWHDPOLQHSUHVVXUHWUDQVPLWWHUVDUHLQFOXGHGLQWKHSRVWILUH

VDIHVKXWGRZQGHVLJQ

&20321(17 '(6&5,37,21

$%37 6WHDP*HQHUDWRU$6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU$6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU$6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU%6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU%6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU%6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU&6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU&6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU&6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU'6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU'6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37 6WHDP*HQHUDWRU'6WHDPOLQH3UHVVXUH7UDQVPLWWHU

 1RUPDODQG$X[LOLDU\3UHVVXUL]HU6SUD\$QRWKHUHOHPHQWUHTXLUHGWRDVVXUH5&6SUHVVXUHFRQWUROIXQFWLRQV

DUHDYDLODEOHLVFRQWURORIQRUPDODQGDX[LOLDU\SUHVVXUL]HUVSUD\%HFDXVHQRUPDOSUHVVXUL]HUVSUD\UHOLHV

XSRQWKHSUHVVXUHGLIIHUHQWLDOEHWZHHQWKHVXUJHOLQHFRQQHFWLRQLQWKH/RRSKRWOHJDQGWKHVSUD\OLQH

FRQQHFWLRQLQWKH/RRSVDQGFROGOHJQRUPDOSUHVVXUL]HUVSUD\LVFRQWUROOHG VWRSSHG LIWKH5&3VDUHQRW

dŽŽŽŽKŽŽŽdŽ

UXQQLQJ,IOHVVWKDQIRXU5&3VDUHRSHUDWLQJWKHSUHVVXUL]HUVSUD\IORZZLOOEHUHGXFHGLIWKH'5&3LVQRW

ŽŽŽŽŽŽtŽŽtŽ

RSHUDWLQJEHFDXVHWKHVWDWLFSUHVVXUHLQWKHVXUJHOLQHORRSZLOOEHQHDUO\HTXDOWRWKHVSUD\VRXUFHORRS7KH

E^^^ŽŽŽŽŽŽKŽŽŽ

QRUPDOSUHVVXUL]HUVSUD\YDOYHVDUHDLURSHUDWHG,VRODWLRQRILQVWUXPHQWDLUWRFRQWDLQPHQWZLOOIDLOWKHYDOYHV

ŽŽWdWdWdWddŽŽ

FORVHG2)153SURYLGHVDFWLRQVWRVWRSWKH5&3VZLWKLQWKHILUVWVHYHQ PLQXWHVIROORZLQJFRQWUROURRP

ŽŽŽŽŽŽŽŽŽŽŽŽŽ

HYDFXDWLRQLQWKHHYHQWRIDFRQWUROURRPILUH,QWKHHYHQWRIDILUHRXWVLGHWKHFRQWUROURRPRSHUDWRUVFDQ

ŽdŽŽŽŽŽ

PLWLJDWHVSXULRXVRSHUDWLRQRIWKHSUHVVXUL]HUVSUD\YDOYHVE\HLWKHUVWRSSLQJWKH5&3VDQGXVLQJQDWXUDO

dŽŽŽW&^^ŽŽŽŽŽ

 FLUFXODWLRQFRROGRZQRULVRODWLQJLQVWUXPHQWDLUWRFRQWDLQPHQWWRIDLOWKHYDOYHVFORVHG 9DOYH.$)9DQG

KDQGVZLWFK.$+,6DUHLQFOXGHGLQWKH3)66'GHVLJQWRLVRODWHLQVWUXPHQWDLUWRFRQWDLQPHQW9DOYH

.$9LVDOVRLQFOXGHGLQWKH3)66'GHVLJQ LQ WKHHYHQW.$)9LVDIIHFWHGE\WKHILUH 7KHUHIRUH

SUHVVXUL]HUQRUPDOVSUD\YDOYHV%%3&9%DQG%%3&9&DQGDVVRFLDWHGFDEOHVDQGFRPSRQHQWVDUH

LQFOXGHGLQWKH3)66'$WRHYDOXDWHZKHWKHUWKHVSUD\YDOYHVZLOOVSXULRXVO\RSHQ

CCN XX-E-013-004-CN008 Attachment 1 Page 4 of 20

)LUH GDPDJH WR WZR RU PRUH LQSXW FKDQQHOV ZRXOG KDYH WR RFFXU DW WKH H[DFW VDPH WLPH DQG IDLO WR WKH H[DFW VDPH YDOXH EXW QRW H[FHHG WKH PD[LPXP 9 YDOXH LQ RUGHU IRU WKH 2YDWLRQ V\VWHP WR FRQVLGHU WKHP YDOLG DQG VLJQDO WKH VSUD\ YDOYHV WR RSHQ 7KLV LV

)250$3)'5(9

QRW FRQVLGHUHG D FUHGLEOH VFHQDULR DQG LV QRW FRQVLGHUHG SRVVLEOH LQ WKH ILUH DUHD DQDO\VLV

APPENDIX 1 CALCULATION NO. XX-E-013 PFSSD FUNCTION EVALUATIONS REVISION NO. 4 (REACTOR MAKEUP) Page 22 7KHSUHVVXUL]HUQRUPDOVSUD\YDOYHV %%3&9%DQG%%3&9& RSHUDWHRIIDVLJQDOIURPWKH

SUHVVXUL]HUSUHVVXUHFRQWUROV\VWHP7KHSUHVVXUL]HUSUHVVXUHPDVWHUFRQWUROOHU %%3.$ UHFHLYHVD

VLJQDOIURPHLWKHU%%37RU%%37GHSHQGLQJRQWKHSRVLWLRQRIWKHSUHVVXUHFKDQQHOVHOHFWRUVZLWFK

%%36) 7KHQRUPDOSRVLWLRQRIWKHVZLWFKKDV%%37VHOHFWHG6ZLWFK%%36)LVFRQQHFWHGWR

UHOD\FDUGVLQSDQHO53/RVVRISRZHUWRWKHUHOD\FDUGVZLOOFDXVHWKHVZLWFKWRUHYHUWWRWKH

%%37%%37SRVLWLRQ,I%%37LVDIIHFWHGE\WKHILUHRSHUDWRUVFDQVZLWFKWR%%37RQO\LI

SRZHUWRWKHUHOD\FDUGVLVDYDLODEOH7KHUHIRUHSRZHUWR53LVLQFOXGHGLQWKH3)66'DQDO\VLV

8SRQLQFUHDVLQJSUHVVXUHLQWKHSUHVVXUL]HUDVGHWHUPLQHGE\WKHPDVWHUFRQWUROOHUWKHVSUD\YDOYHVRSHQWR

FRPSHQVDWHIRUWKHSUHVVXUHLQFUHDVH$W:ROI&UHHNRQHVHWRISUHVVXUL]HUEDFNXSKHDWHUVLVQRUPDOO\

PDLQWDLQHGHQHUJL]HG7KLVFDXVHVWKHPDVWHUFRQWUROOHURXWSXWWRLQFUHDVHDVSUHVVXUHJRHVXS7KLVRXWSXW UHVXOWVLQWKHSUHVVXUL]HUVSUD\YDOYHVRSHQLQJWRFRPSHQVDWHIRUWKHKHDWLQSXWWRWKHSUHVVXUL]HU7KHHQG

UHVXOWLV5&6IOXLGIURPWKHVSUD\OLQHVFRQWLQXDOO\PL[LQJLQWKHSUHVVXUL]HUPDLQWDLQLQJWKHERULFDFLGDQG

FKHPLFDOFRQFHQWUDWLRQVHTXDOWRWKH5&6

3UHVVXUL]HUDX[LOLDU\VSUD\YDOYH%*+9LVQRWLQFOXGHGLQWKHSRVWILUHVDIHVKXWGRZQGHVLJQEHFDXVH

DOWHUQDWLYHDQGUHGXQGDQWPHDQVDUHDYDLODEOHWRSUHYHQWDX[LOLDU\VSUD\7KHSUHVVXUL]HUDX[LOLDU\VSUD\WDSLV

RQWKHFKDUJLQJOLQHGRZQVWUHDPRIWKHUHJHQHUDWLYHKHDWH[FKDQJHU7KHUHIRUHLVRODWLRQRIWKHQRUPDO

FKDUJLQJOLQHZLOOSUHYHQWDX[LOLDU\SUHVVXUL]HUVSUD\,Q2)153QRUPDOFKDUJLQJLVLVRODWHGE\FORVLQJ

%*%)RUILUHVRXWVLGHWKHFRQWUROURRPQRUPDOFKDUJLQJLVLVRODWHGE\FORVLQJHLWKHU%*+9RU

%*+9+RZHYHULQRQHILUHDUHD $ LWPD\QRWEHSRVVLEOHWRFORVHYDOYHV%*+9DQG

%*+9EHFDXVHWKHVHYDOYHVDUHORFDWHGLQILUHDUHD$DQGDILUHFRXOGGDPDJHWKHSRZHUFDEOHV6HH

ILUHDUHD$DQDO\VLVLQ()IRUIXUWKHUGLVFXVVLRQDERXWWKLVFRQILJXUDWLRQ

 3UHVVXUL]HU+HDWHUV3UHVVXUL]HUKHDWHUVDUHQRWFUHGLWHGLQWKHUHGXQGDQWSRVWILUHVDIHVKXWGRZQGHVLJQ 

&)5$SSHQGL[56HFWLRQ,,,*DUHDV &DOFXODWLRQ:&12&&3LVDWKHUPDOK\GUDXOLFWUDQVLHQW

DQDO\VLVIRUWKH:ROI&UHHNSODQWIRUYDULRXVILUHVFHQDULRV7KHSUHVVXUL]HUKHDWHUVZHUHPRGHOHGRQRURIIIRU

HDFKVFHQDULRWRGHWHUPLQHZRUVHFDVHHIIHFW%DVHGRQWKHUHVXOWVRSHUDWLRQRUPDORSHUDWLRQRIWKH

SUHVVXUL]HUKHDWHUVKDGQRDGYHUVHLPSDFWRQ3)66'$Q\PLQLPDOLPSDFWFRXOGEHRIIVHWE\DYDLODEOH

3)66'HTXLSPHQW7KHUHIRUHWKHSUHVVXUL]HUKHDWHUVDUHQRWLQFOXGHGLQWKH3)66'DQDO\VLV

7KHEDFNXSJURXS%SUHVVXUL]HUKHDWHUVDUHFUHGLWHGLQWKHDOWHUQDWLYHSRVWILUHVDIHVKXWGRZQGHVLJQ &)5

$SSHQGL[56HFWLRQ,,,*DUHDV 3URFHGXUH2)153KDVRSHUDWRUVPDLQWDLQSUHVVXUL]HUSUHVVXUH

ZLWKLQDFFHSWDEOHSDUDPHWHUV7KLVLVGRQHE\F\FOLQJWKHEDFNXSJURXS%KHDWHUVRQDQGRIIDVQHFHVVDU\

&DOFXODWLRQ6$DVVXPHVWKHSUHVVXUL]HUEDFNXSJURXS%KHDWHUVDUHFRQWUROOHGLQ2)153ZLWKLQ

PLQXWHVIROORZLQJUHDFWRUWULS7KHEDFNXSJURXS%KHDWHUVDUHLVRODWHGIURPWKHFRQWUROURRPXVLQJ

53+,6RQSDQHO53%+DQGVZLWFK%%+,6%FRQWUROVWKHSRVLWLRQRILQFRPLQJ3*IHHGHU

EUHDNHU3*IURPDX[LOLDU\VKXWGRZQSDQHO53%%XV3*LVWKHSRZHUGLVWULEXWLRQEXVIRUWKH

EDFNXSJURXS%KHDWHUV%XV3*LVIHGIURP1%7KHVHFRPSRQHQWVDUHLQFOXGHGLQWKHDOWHUQDWLYH

3)66' GHVLJQ

 3UHVVXUL]HU3UHVVXUH,QGLFDWLRQ3UHVVXUL]HUSUHVVXUHLQGLFDWLRQLVLQFOXGHGLQWKH3)66'GHVLJQWRSURYLGH

RSHUDWRUVZLWKDZD\RIGLDJQRVLQJDQRSHQ3259EORFNYDOYHIORZSDWKRUVSXULRXVSUHVVXUL]HUVSUD\7KH

IROORZLQJSUHVVXUL]HUSUHVVXUHLQGLFDWRUVDUHLQFOXGHG

&20321(17 '(6&5,37,21

%%3,$ 3UHVVXUL]HU3UHVVXUH,QGLFDWRU

%%3, 3UHVVXUL]HU3UHVVXUH,QGLFDWRU

%%3, 3UHVVXUL]HU3UHVVXUH,QGLFDWRU

%%3, 3UHVVXUL]HU3UHVVXUH,QGLFDWRU dW&^^ŽŽKŽE^^^

ŽŽ^^

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

BBLI0460B 2 Pressurizer Level Indicator 1413S A-28 RP118B M --- X X --- X M-12BB02 E-13SB09 M-761-00076 NN0217 XX-E-013-001-CN004 2 (Narrow Range) E-03SB16 M-761-00495 M-761-02304 CCN XX-E-013-004-CN008 BBLT0459 1 Pressurizer Level Transmitter RB4 RB-4 --- M --- X X X --- M-12BB02 E-13BB16 M-761-00042 NN0111 --- 0 (Narrow Range) E-13SB09 M-761-00076 M-761-2019 BBLT0460 2 Pressurizer Level Transmitter RB4 RB-4 --- M --- X X X X M-12BB02 E-13BB16 M-761-00076 NN0217 --- 0 (Narrow Range) E-13SB09 M-761-00495 M-761-02304 BBPB0403A 2 Reactor Coolant Sys Press 3605 C-27 SB042 H --- --- X X X M-12BB04 E-13BB15 M-761-00101 NN0212 Required for cold shutdown - If 0 Wide Range Hot Leg E-13NN01 control room not accessible or E-13SB09 circuit damaged, locally open BBPV8702B BBPB0405A 1 Reactor Coolant Sys Press 3605 C-27 SB038 H --- --- X X X M-12BB04 E-13BB15 M-761-00101 NN0111 For alternate shutdown, locally 0 Wide Range Hot Leg E-13NN01 operate EJHV8701B to transition E-13SB09 to cold shutdown Attachment 1 BBPCV0455A 1 Pressurizer Power Operated RB-10 RB-10 --- M --- X X X X M-12BB02 E-13BB39 --- NK5108 XX-E-013-002-CN002 XX-E- 4 Relief Valve E-13BB40 WE 013-003-CN006 E-11NK01 WE BBPCV0455B 5 Pressurizer Spray Valve RB-10 RB-10 --- M --- X X X X M-12BB02 E-13BB19 ---

D PG19GCR218 XX-E-013-003-CN006 4 PN001 BBPCV0455C 5 Pressurizer Spray Valve RB-10 RB-10 --- M --- X X X X M-12BB02 E-13BB19 ---

D PG19GCR218 XX-E-013-003-CN006 4 PN001 BBPCV0456A 4 Pressurizer Power Operated RB-10 RB-10 --- M --- X X X X M-12BB02 E-13BB39 --- NK4421 XX-E-013-002-CN002 XX-E- 4 Relief Valve E-13BB40 WE 013-003-CN006 E-11NK02 WE BBPI0405 1 Reactor Coolant Sys Press 3601 C-27 RL022 H --- X X X --- M-12BB04 E-13BB15 M-761-00101 NN0111 --- 0 Wide Range Hot Leg E-13NN01 E-13SB09 BBPI0406 4 Reactor Coolant Sys Press 3601 C-27 RL022 H --- X X X --- M-12BB04 E-13BB16 M-761-00496 NN0420 --- 0 Wide Range Hot Leg E-13NN01 M-761-00101 E-13SB09 BBPI0406X 4 Reactor Coolant Sys Press 1413S A-28 RP118B H --- X X --- X M-12BB04 E-13BB16 M-761-00496 NN0420 XX-E-013-001-CN004 XX-E- 2 Wide Range Hot Leg E-13NN01 013-001-CN011 Page 5 of 20 E-13SB09 E-13SB16

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

BBPI0455A 5 Pressurizer Pressure Indicator 3601 C-27 RL002 S M X X X --- M-12BB02 E-13SB08A J-200-00095 NN0111 --- 2 M-761-00133 M-761-02018 CCN XX-E-013-004-CN008 BBPI0456 6 Pressurizer Pressure Indicator 3601 C-27 RL002 S M X X X --- M-12BB02 E-13SB08A J-200-00095 NN0212 --- 2 M-761-00135 M-761-02048 BBPI0457 5 Pressurizer Pressure Indicator 3601 C-27 RL002 S M X X X --- M-12BB02 E-13SB08B J-200-00095 NN0311 --- 2 M-761-00137 M-761-02079 BBPI0458 6 Pressurizer Pressure Indicator 3601 C-27 RL002 S M X X X --- M-12BB02 E-13SB08B J-200-00095 NN0414 --- 2 M-761-00139 M-761-02102 BBPK0455A 5 Pressurizer Master Controller 3601 C-27 RL002 M --- X X X --- --- E-13SC03 J-200-00095 PG19GCR218 --- 2 M-761-00141 PN001 M-761-02127 BBPK0455B 5 BBPCV0455B Auto/Manual 3601 C-27 RL002 M --- X X X --- --- E-13SC03 J-200-00095 PG19GCR218 --- 2 Controller M-761-00141 PN001 Attachment 1 M-761-02128 BBPK0455C 5 BBPCV0455C Auto/Manual 3601 C-27 RL002 M --- X X X --- --- E-13SC03 J-200-00095 PG19GCR218 --- 2 Controller M-761-00141 PN001 M-761-02129 BBPS0455F 6 Pressure Channel Selector 3601 C-27 RL002 M --- X X X --- --- E-13SC01 J-200-00095 PG20GBR219 --- 2 Switch M-761-00142 PN002 BBPT0403 2 Reactor Coolant Sys Press 1202 A-1 --- H --- --- X X X M-12BB04 E-13BB12A M-761-00101 NN0212 Required for cold shutdown - If 0 Wide Range Hot Leg E-13BB12B control room not accessible or E-13BB15 circuit damaged, locally open E-13NN01 BBPV8702B E-13SB02 E-13SB09 BBPT0405 1 Reactor Coolant Sys Press 1320 A-8 --- H --- X X X X M-12BB04 E-13BB15 M-761-00101 NN0111 For alternate shutdown, locally 0 Wide Range Hot Leg E-13NN01 operate EJHV8701B to transition E-13SB01 to cold shutdown E-13SB08D E-13SB09 BBPT0406 4 Reactor Coolant Sys Press 1202 A-1 --- H --- X X X X M-12BB04 E-13BB16 M-761-00101 NN0420 --- 0 Wide Range Hot Leg E-13NN01 M-761-00496 Page 6 of 20 E-13SB09

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

BBPT0455 1 Pressurizer Pressure RB4 RB-4 --- S --- X X X X M-12BB02 E-13BB16 M-761-00042 NN0111 Safety Injection could be 0 Transmitter E-13NN01 M-767-00347 initiated by low pressurizer E-13SB09 M-761-02018 pressure.

CCN XX-E-013-004-CN008 E-13SB01 E-13SB02 BBPT0456 2 Pressurizer Pressure RB4 RB-4 --- S --- X X X X M-12BB02 E-13BB16 M-761-00043 NN0212 Safety Injection could be 0 Transmitter E-13NN01 M-767-00347 initiated by low pressurizer E-13SB09 M-761-02048 pressure.

E-13SB01 E-13SB02 BBPT0457 3 Pressurizer Pressure RB10 RB-10 --- S --- X X X X M-12BB02 E-13BB16 M-761-00044 NN0311 Safety Injection could be 0 Transmitter E-13NN01 M-767-00347 initiated by low pressurizer E-13SB09 M-761-02079 pressure.

E-13SB01 E-13SB02 BBPT0458 4 Pressurizer Pressure RB10 RB-10 --- S --- X X X X M-12BB02 E-13BB16 M-761-00044 NN0414 Safety Injection could be 0 Transmitter E-13NN01 M-767-00347 initiated by low pressurizer Attachment 1 E-13SB09 M-761-02102 pressure.

E-13SB01 E-13SB02 BBPV8702A 4 RCS Hot Leg 1 to RHR Pump A RB1 RB-1 --- M, H --- X X X X M-12BB01 E-13BB12A --- NG02BCF2 High Low Pressure Interface - 0 Suction Iso Vlv Valve administratively controlled closed - Manually open valve to transition to cold shutdown if interlock not functional BBPV8702B 4 RCS Hot Leg 4 to RHR Pump B RB1 RB-1 --- M, H --- X X X X M-12BB01 E-13BB12B --- NG02BBF3 High Low Pressure Interface - 0 Suction Iso Vlv Valve administratively controlled closed - Manually open valve to transition to cold shutdown if interlock not functional BBPY0455BA 5 Pressurizer Spray Valve RB-10 RB-10 --- M --- X X X X M-12BB02 E-13BB19 --- PG19GCR218 XX-E-013-003-CN006 4 BBPCV0455B I/P Converter PN001 Page 7 of 20 WE

WE

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

BBPY0455CA 5 Pressurizer Spray Valve RB-10 RB-10 --- M --- X X X X M-12BB02 E-13BB19 --- PG19GCR218 XX-E-013-003-CN006 4 BBPCV0455C I/P Converter PN001 WE

CCN XX-E-013-004-CN008 WE BBTE0413A 1 RCS Hot Leg Temp Element RB1 RB-1 --- H --- X X X --- M-12BB01 E-13BB15 M-761-00042 NN0111 --- 0 (WR) Loop 1 E-13NN01 M-761-00070 E-13SB09 BBTE0413B 2 RCS Cold Leg Temp Element RB1 RB-1 --- H --- X X X --- M-12BB01 E-13BB15 M-761-00043 NN0212 --- 0 (WR) Loop 1 E-13NN01 M-761-00071 E-13SB09 BBTE0423A 1 RCS Hot Leg Temp Element RB1 RB-1 --- H --- X X X --- M-12BB01 E-13BB15 M-761-00042 NN0111 --- 0 (WR) Loop 2 E-13NN01 E-13SB09 BBTE0423B 2 RCS Cold Leg Temp Element RB1 RB-1 --- H --- X X X X M-12BB01 E-13BB15 M-761-00071 NN0217 --- 0 (WR) Loop 2 E-13NN01 E-13SB09 BBTE0433A 2 RCS Hot Leg Temp Element RB1 RB-1 --- H --- X X X --- M-12BB01 E-13BB15 M-761-00043 NN0212 --- 0 (WR) Loop 3 E-13NN01 Attachment 1 E-13SB09 BBTE0433B 1 RCS Cold Leg Temp Element RB1 RB-1 --- H --- X X X --- M-12BB01 E-13BB15 M-761-00042 NN0111 --- 0 (WR) Loop 3 E-13NN01 E-13SB09 BBTE0443A 2 RCS Hot Leg Temp Element RB1 RB-1 --- H --- X X X X M-12BB01 E-13BB15 M-761-00071 NN0217 --- 0 (WR) Loop 4 E-13NN01 E-13SB09 BBTE0443B 1 RCS Cold Leg Temp Element RB1 RB-1 --- H --- X X X --- M-12BB01 E-13BB15 M-761-00042 NN0111 --- 0 (WR) Loop 4 E-13NN01 E-13SB09 BBTI0413A 1 RCS Hot Leg Temp Indicator 3601 C-27 RL021 H --- X X X --- M-12BB01 E-13BB15 M-761-00070 NN0111 --- 0 (WR) Loop 1 E-13NN01 E-13SB08D E-13SB09 BBTI0413B 2 RCS Cold Leg Temp Indicator 3601 C-27 RL021 H --- X X X --- M-12BB01 E-13BB15 M-761-00071 NN0212 --- 0 (WR) Loop 1 E-13NN01 E-13SB08D E-13SB09 BBTI0423A 1 RCS Hot Leg Temp Indicator 3601 C-27 RL021 H --- X X X --- M-12BB01 E-13BB15 M-761-00070 NN0111 --- 0 Page 8 of 20 (WR) Loop 2 E-13NN01 E-13SB09

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

BGHV8153B 4 Excess Letdown/RCS Isolation RB1 RB-1 --- M --- X X X X M-12BG01 E-13BG48 --- NK4407 High Low Pressure Interface - 0 Valve E-13RL02 Valve fails closed with power removed CCN XX-E-013-004-CN008 BGHV8154A 1 Excess Letdown/RCS Isolation RB1 RB-1 --- M --- X X X X M-12BG01 E-13BG48 --- NK4119 High Low Pressure Interface - 0 Valve E-13RL02 Valve fails closed with power removed BGHV8154B 4 Excess Letdown/RCS Isolation RB1 RB-1 --- M --- X X X X M-12BG01 E-13BG48 --- NK4407 High Low Pressure Interface - 0 Valve E-13RL02 Valve fails closed with power removed BGHV8357A 1 CCP A Discharge to RCP Seals 1114 A-2 --- R, M --- X X X --- M-12BG03 E-13BG52 --- NG01AGR4 --- 0 Valve BGHV8357B 4 CCP B Discharge to RCP Seals 1107 A-4 --- R, M --- X X X X M-12BG03 E-13BG52 --- NG02ADR5 --- 0 Valve BGHY0459 5 BGLCV0459 Solenoid Valve RB9 RB-9 --- M --- X X X X M-12BG01 E-13BG10 --- PK5117 --- 0 Attachment 1 E-13RL02 BGHY0460 5 BGLCV0460 Solenoid Valve RB9 RB-9 --- M --- X X X X M-12BG01 E-13BG10 --- PK5117 --- 0 E-13RL02 BGLCV0112B 1 VCT Iso Vlv from Charging 1318 A-8 --- R, M --- X X X --- M-12BG03 E-13BG12 --- NG01AFF2 --- 0 Pump Suction Valve BGLCV0112C 4 VCT Iso Vlv from Charging 1318 A-8 --- R, M --- X X X X M-12BG03 E-13BG12A --- NG02AFR2 --- 0 Pump Suction Valve BGLCV0459 5 Letdown Isolation Valve RB9 RB-9 --- M --- X X X X M-12BG01 E-13BG10 --- PK5117 High / Low Pressure Interface 0 E-13RL02 BGLCV0459X 5 Pressurizer Low Level 3605 C-27 RP043 M --- X X X --- M-12BG01 E-13BG10 ---

D PK5117 --- 0 Transistor Z D PN01 WE

PG19GCR218 WE BGLCV0460 5 Letdown Isolation Valve RB9 RB-9 --- M --- X X X X M-12BG01 E-13BG10 --- PK5117 High / Low Pressure Interface 0 E-13RL02 BGLCV0460X 5 Pressurizer Low Level 3605 C-27 RP043 M --- X X X --- M-12BG01 E-13BG10 ---

D PK5117 --- 0 Transistor Z D PN01 WE

PG19GCR218 WE BGLT0112 1 VCT Level Transmitter 1318 A-8 --- R, M --- X X X --- M-12BG03 E-13BG51 M-761-00042 NN0111 If charging pump suction fails to 0 E-13SB09 shift to RWST, locally open Page 9 of 20 BNLCV0112D and close BGLCV0112B

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

NG03DEF110 1 Electro Hydraulic Damper 5203 D-1 --- S R, M, H X X X --- --- E-11NG21 --- NG03D XX-E-013-003-CN006 4 Actuator (GMTZ1A)

NG03DEF111 1 Electro Hydraulic Damper 5203 D-1 --- S R, M, H X X X --- --- E-11NG21 --- NG03D XX-E-013-003-CN006 4 CCN XX-E-013-004-CN008 Actuator (GMTZ1B)

NG03DEF4 1 Emergency Fuel Oil Xfer Pump 5203 D-1 --- S R, M, H X X X --- --- E-13JE01 --- NG03D XX-E-013-003-CN006 4 Motor (DPJE01A) E-11NG20 NG03T 1 480V Class 1E Motor Control 1410 A-18 --- S R, M, H X X X --- --- E-03NG01 --- NG0305 --- 0 Center E-11NG01 NG03TAF1 1 Containment Cooler Fan Motor 1410 A-18 --- S R, M, H X X X X --- E-13GN02 --- NG0305 --- 0 (DSGN01C) E-03NG01 E-11NG20 NG04 4 480V Class 1E Load Center 3302 C-10 --- S R, M, H X X X X --- E-01NB02 --- XNG04 --- 0 E-13NB05 E-03NG01 E-11NG02 KD-7496 NG0401 4 480V Class 1E Load Center 3302 C-10 --- S R, M, H X X X X --- E-11NG02 --- XNG04 XX-E-013-001-CN011 2 Attachment 1 Incoming Feeder E-13NG01A E-13NG11A KD-7496 NG0403 4 125VDC Class 1E Battery 3302 C-10 --- S R, M, H X X X X --- E-11NG02 --- NG04 --- 0 Charger (NK22)

NG0405 4 480V Class 1E MCC (NG04T) 3302 C-10 --- S R, M, H X X X X --- E-11NG02 --- NG04 --- 0 NG0406 4 480V Class 1E Auxiliary 3302 C-10 --- S R, M, H X X X X --- E-11NG02 --- NG04 --- 0 Building MCC (NG04C)

NG0407 4 480V Class 1E Diesel Gen 3302 C-10 --- S R, M, H X X X X --- E-03NG01 --- NG04 --- 0 Room MCC (NG04D) E-11NG02 NG0409 4 125VDC Non-Class 1E Battery 3302 C-10 --- S R, M, H X X X --- --- E-11NG02 --- NG04 --- 0 Charger (PK22)

NG0411 4 125VDC Class 1E Swing 3302 C-10 --- S R, M, H X X X --- --- E-11NG02 --- NG04 --- 0 Battery Charger (NK26)

NG04C 4 480V Class 1E Auxiliary 1501 A-21 --- S R, M, H X X X X --- E-03NG01 --- NG0406 --- 0 Building MCC E-11NG02 NG04CCF2 4 MDAFWP B Discharge to SG B 1501 A-21 --- S H X X X X --- E-13AL09 --- NG04C --- 0 Vlv - 120V (ALHV0005) E-11NG20 Page 10 of 20 E'sEŽ^,yyyE'E'

W<

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

PG12KAF5 6 Main Steam to Steam Seal Iso 4401W TURB --- S R, H X X X --- --- E-13AB22 E-11PG20 PG12K Needed for MSIV failure, fire in A- 2 Valve (ABHV0046) 15 or A-23 PG12KAF6 6 480V Non-Class 1E Load 4401W TURB --- S R, H X X X --- --- E-13PBG03 E-11PG20 PG1207 Needed for MSIV failure, fire in A- 2 CCN XX-E-013-004-CN008 Center Incoming Feeder 15 or A-23 PG12KEF3 6 Main Steam Iso to Aux Steam 4401W TURB --- S R, H X X X --- --- E-13FB12 E-11PG20 PG12K Needed for MSIV failure, fire in A- 2 Reboiler (FBHV0080) 15 or A-23 PG1300 5 480V Non-Class 1E LC Feeder 4401W TURB --- S R, H X X X --- --- E-13PG01 --- PA0105 Needed for MSIV failure, fire in A- 0 from PA0105 KD-7496 15 or A-23 PG1400 6 480V Non-Class 1E LC Feeder 4401W TURB --- S R, H X X X --- --- E-13PG04 --- PA0207 Needed for MSIV failure, fire in A- 0 from PA0207 KD-7496 15 or A-23 PG1500 5 480V Non-Class 1E LC Feeder 4401W TURB --- S R, H X X X --- --- E-13PG02 --- PA0106 Needed for MSIV failure, fire in A- 0 from PA0106 15 or A-23 PG1600 6 480V Non-Class 1E LC Feeder 4401W TURB --- S R, H X X X --- --- E-13PG03 --- PA0206 Needed for MSIV failure, fire in A- 0 from PA0206 KD-7496 15 or A-23 PG19 5 480V Non-Class 1E Load 1314 A-8 --- S R, M, H X X X X --- E-13PG02 --- XPG19 --- 0 Center KD-7496 Attachment 1 PG1900 5 480V Non-Class 1E LC Feeder 1314 A-8 --- S R, H X X X --- --- E-13PG02 --- PG1500 Needed for MSIV failure, fire in A- 0 from PG1500 15 or A-23 PG1901 5 480V Non-Class 1E Load 1314 A-8 --- S R, H X X X --- --- E-13PG02 --- XPG19 Needed for MSIV failure, fire in A- 0 Center Incoming Feeder KD-7496 15 or A-23 PG1907 5 480V Non-Class 1E Auxiliary 1314 A-8 --- S R, M, H X X X X --- E-13PG02 --- PG19 --- 0 Bldg MCC (PG19G)

PG19G 5 480V Non-Class 1E Auxiliary 1403 A-27 --- S R, M, H X X X X --- E-13PG02 E-11PG20 PG1907 --- 2 Building MCC PG19GAF1 5 5KVA Process Control Inverter 1403 A-27 --- S M X X X X --- E-13SC12 E-11PG20 PG19G --- 2 (PN01)

PG19GAF8 5 Incoming Line from Load 1403 A-27 --- S R, H X X X --- --- E-13PG02 E-11PG20 PG1907 --- 2 Center PG19 PG19GCR2 5 480VAC Non-Class 1E 1403 A-27 --- S R, M, H X X X X --- E-11PG21 E-11PG20 PG19G --- 2 Distribution Panel E-13AB04 E-13AB18 E-13RL07 E-13PG02 Page 11 of 20 W&sEŽdŽ^,yyyWEW'W

WE

W&sEŽdŽ^,yyyWEW'W

WE

$33(1',; &$/&8/$7,2112;;(

0RYH WKLV OLQH WR 31 5(9,6,2112

3)66'&20321(17/,67 VHFWLRQ 6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

PG19GCR217 5 MCB Misc. Power Circuits 1403 A-27 --- S R, H X X X --- --- E-13AB04 E-11PG20 PG19G Needed for MSIV failure, fire in A- 2 (RL023) E-13AB18 15 or A-23 E-13RL07 E^^^ŽŽ

CCN XX-E-013-004-CN008 E-13PG02 ZWW^

PG19GCR218 5 Process Control Rack - Group 1403 A-27 --- S M X X X --- --- E-13PG02 E-11PG20 PG19G --- 2 WE 1 (RP043)  WE WE PG19GFR3 5 Instr Bus Transformer - Alt. 1403 A-27 --- S H X X X --- --- E-13PN01 E-11PG20 PG19G --- 2 Feed (XPN07D)

PG20 6 480V Non-Class 1E Load 1403 A-27 --- S R, H X X X --- --- E-13PG04 --- XPG20 --- 0 Center E-13PA13 KD-7496 PG2000 6 480V Non-Class 1E LC Feeder 1403 A-27 --- S R, H X X X --- --- E-13PG04 --- PG2400 Needed for MSIV failure, fire in A- 0 from PG2400 KD-7496 15 or A-23 PG2001 6 480V Non-Class 1E Load 1403 A-27 --- S R, H X X X --- --- E-13PA13 --- XPG20 Needed for MSIV failure, fire in A- 0 Center Incoming Feeder KD-7496 15 or A-23 PG2008 6 480V Non-Class 1E Auxiliary 1403 A-27 --- S R, H X X X --- --- E-13PG04 --- PG20 --- 0 Bldg MCC (PG20G) E-13PA13 Attachment 1 PG20G 6 480V Non-Class 1E Auxiliary 1403 A-27 --- S R, H X X X --- --- E-13PG04 E-11PG20 PG2008 --- 2 Building MCC E-13PA13 PG20GAF1 6 Incoming Line from Load 1403 A-27 --- S R, H X X X --- --- E-13PG04 E-11PG20 PG2008 --- 2 Center PG20 E-13PA13 PG20GAF2 6 5 kVA Process Control Inverter 1403 A-27 --- S M X X X --- --- E-13SC12 E-11PG20 PG20G --- 2 (PN02)

PG20GBR2 6 480VAC Non-Class 1E 1403 A-27 --- S R, H X X X --- --- E-13AB18 E-11PG20 PG20G Needed for MSIV failure, fire in A- 2 Distribution Panel E-13RL07 15 or A-23 PG20GBR217 6 MCB Misc. Power Circuits 1403 A-27 --- S R, H X X X --- --- E-13AB18 E-11PG20 PG20G Needed for MSIV failure, fire in A- 2 (RL023) E^^^ŽŽ E-13RL07 15 or A-23 ZWW^

PG20GBR219 6 Process Control Rack - Group 1403 A-27 --- S M X X X --- --- E-13SC12 E-11PG20 PG20G --- 2 WE 2 (RP047)  WE WE PG20GER5 6 Instr Bus Transformer - Alt. 1403 A-27 --- S H X X X --- --- E-13PN01A E-11PG20 PG20G --- 2 Feed (XPN08D)

PG22 6 480V Non-Class 1E Load 1409 A-17 --- M --- X X --- X --- E-13PG05 --- NB0208 Required for alternate shutdown 3 Center per OFN RP-017 XX-E-013-002-CN007 PG2201 6 480V Non-Class 1E Load 1409 A-17 --- M --- X X --- X --- E-13PG05 --- NB0208 Required for alternate shutdown 3 Page 12 of 20 Center PG22 Feeder Breaker per OFN RP-017 XX-E-013-002-CN007 0RYH WKLV OLQH WR 31 VHFWLRQ

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

PG2400 6 480V Non-Class 1E LC Feeder 1403 A-27 --- S R, H X X X --- --- E-13PG04 --- PG1400 Needed for MSIV failure, fire in A- 0 from PG1400 KD-7496 15 or A-23 XPG11 5 480V Non-Class 1E LC Xfmr - 4351 T-2 --- S R, H X X X --- --- E-13PG01 --- PG1100 Needed for MSIV failure, fire in A- 0 CCN XX-E-013-004-CN008 Turbine Building KD-7496 15 or A-23 XPG12 6 480V Non-Class 1E LC Xfmr - 4351 T-2 --- S R, H X X X --- --- E-13PG03 --- PG1200 Needed for MSIV failure, fire in A- 0 Turbine Building KD-7496 15 or A-23 XPG19 5 480V Non-Class 1E LC Xfmr - 1314 A-8 --- S R, H X X X --- --- E-13PG02 --- PG1900 Needed for MSIV failure, fire in A- 0 Auxiliary Bldg KD-7496 15 or A-23 XPG20 6 480V Non-Class 1E LC Xfmr - 1403 A-27 --- S R, H X X X --- --- E-13PA13 --- PG2000 Needed for MSIV failure, fire in A- 0 Auxiliary Bldg KD-7496 15 or A-23 XPG22 6 480V Non-Class 1E LC Xfmr - 1409 A-17 --- S --- X X --- X --- E-13PG05 --- NB0208 Required for alternate shutdown 3 Pressurizer Heaters Group B per OFN RP-017 PGHIS0002 5 13.8KV Non-Class 1E Load 3601 C-27 RL016 S R, H X X X --- --- E-13PG10 --- PK4103 Used to trip RDMG SF001 for 3 Center Feeder PA0106 Hand fire in A-27 Switch PGHIS0003 6 13.8KV Non-Class 1E Load 3601 C-27 RL016 S R, H X X X --- --- E-13PG11 --- PK6204 Used to trip RDMG SF002 for 3 Attachment 1 Center Feeder PA0207 Hand fire in A-27 Switch PK01 5 125VDC Non-Class 1E Bus 4405 TURB --- S R, M, H X X X X --- E-11PK01 --- PK11 --- 0 PK0101 5 125VDC Non-Class 1E Line 4405 TURB --- S R, M, H X X X X --- E-11PK01 --- PK21 --- 0 from/to PK11 PK0102 5 125VDC Non-Class 1E from 4405 TURB --- S M X X X --- --- E-11PK01 --- PK01 --- 0 Battery Chgr PK21 PK0104 5 125VDC Non-Class 1E Distr 4405 TURB --- S R, H x X X --- --- E-11PK01 --- PK01 Needed for MSIV failure, fire in A- 0 Swbd (PK41) 15 or A-23 PK0106 5 125VDC Non-Class 1E Distr 4405 TURB --- S R, M, H X X --- X --- E-11PK01 --- PK01 --- 0 Swbd (PK61)

PK0112 5 125VDC Non-Class 1E Distr 4405 TURB --- S R, M, H X X X --- --- E-11PK02 --- PK12 --- 0 Swbd (PK51) PK22 PK02 6 125VDC Non-Class 1E Bus 4405 TURB --- S R, M, H X X X --- --- E-11PK02 --- PK12 --- 0 PK22 PK0201 6 125VDC Non-Class 1E Line 4405 TURB --- S R, M, H X X X --- --- E-11PK02 --- PK22 --- 0 from/to PK12 PK0202 6 125VDC Non-Class 1E from 4405 TURB --- S R, M, H X X X --- --- E-11PK02 --- PK02 --- 0 Page 13 of 20 Battery Chgr PK22 W<sEŽdŽdhZ^,yyyW<WEW<

WE

W<sEŽ^,yyyW<W<

W<

W<sEŽ^,yyyW<W<

dŽWE

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

PK0204 6 125VDC Non-Class 1E Distr 4405 TURB --- S M X X X --- --- E-11PK02 --- PK02 --- 2 Swbd (PK42)

PK0206 6 125VDC Non-Class 1E Distr 4405 TURB --- S R, M, H X X X --- --- E-13PA14 --- XMR01 --- 0 CCN XX-E-013-004-CN008 Swbd (PK62) E-11PK02 PK6204 E-11PA02 KD7496 PK0211 5 125VDC Non-Class 1E Distr 4405 TURB --- S R, M, H X X X --- --- E-11PK02 --- PK02 --- 0 Swbd (PK52)

PK11 5 125VDC Non-Class 1E Battery 4404 TURB --- S R, M, H X X --- X --- E-11PK01 --- PK0101 --- 0 PK21 PK12 6 125VDC Non-Class 1E Battery 4404 TURB --- S R, M, H X X X --- --- E-11PK02 --- PK0201 --- 0 PK22 PK21 5 125VDC Non-Class 1E Battery 4405 TURB --- S R, M, H X X --- X --- E-11PK01 --- NG0102 --- 0 Charger E-11NG01 PK22 6 125VDC Non-Class 1E Battery 4405 TURB --- S R, M, H X X X --- --- E-11PK02 --- NG0409 XX-E-013-001-CN011 2 Charger E-11NG02 E-13PK11 Attachment 1 PK41 5 125VDC Non-Class 1E 4405 TURB --- S R, H X X X --- --- E-11PK01 --- PK4100 Needed for MSIV failure, fire in A- 0 Distribution Switchboard 15 or A-23 PK4100 5 125VDC Non-Class 1E Distr 4405 TURB --- S R, H X X X --- --- E-11PK01 --- PK0104 Needed for MSIV failure, fire in A- 0 Swbd Incoming Fdr 15 or A-23 PK4103 5 PA01 Breaker Control Power 4405 TURB --- S R, H X X X X --- E-11PK01 --- PK41 Needed for MSIV failure, fire in A- 0 (Outgoing Brkrs) 15 or A-23 PK4114 5 Main Turbine Stop Valves 4405 TURB --- S R, H X X X --- --- E-11PK01 --- PK41 Needed for MSIV failure, fire in A- 3 Manual Trip (AC119D) 15 or A-23. XX-E-013-002-CN008 PK42 6 125VDC Non-Class 1E 1403 A-27 --- S M X X X --- --- E-11PK02 --- PK42 --- 2 Distribution Switchboard PK4200 6 125VDC Non-Class 1E Distr 1403 A-27 --- S M X X X --- --- E-11PK02 --- PK42 --- 2 Swbd Incoming Fdr PK4207 6 5 kVA Process Control Inverter 1403 A-27 --- S M X X X --- --- E-11PK02 --- PK42 --- 2 (PN02) E-13SC12 PK51 5 125VDC Non-Class 1E 1403 A-27 --- S R, M, H X X X X --- E-11PK01 --- PK0112 --- 0 Distribution Switchboard PK5100 5 125VDC Non-Class 1E Distr 1403 A-27 --- S R, M, H X X --- X --- E-11PK01 --- PK0112 --- 0 Swbd Incoming Fdr Page 14 of 20 W<sEŽ^,yyyW<E'



W<sEŽŽ^,yyyW<E'

W<

W<sEŽ^,yyyW<W<

W<

W<sEŽ^,yyyW<W<

>ŽŽW<

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

PK5113 5 Master Supervisory Station 1403 A-27 --- S R, M, H X X --- --- --- E-11PK01 --- PK51 RP060 is required for a fire in 1 (RP060) area C-9 and C-10 to de-energize the NB bus.

CCN XX-E-013-004-CN008 PK5117 5 RC & Support Sys Control 1403 A-27 --- S R, M X X X X --- E-11PK01 --- PK51 --- 0 Panel (RL001/RL002) E-13RL02 PK5123 5 Steam Generator Blowdown 1403 A-27 --- S R, M, H X X --- X --- E-11PK01 --- PK51 --- 0 Control Pnl (BM157)

PK5126 5 Auxiliary Relay Rack (RP330) 1403 A-27 --- S R, M X X X --- --- E-11PK01 --- PK51 --- 0 E-13RP09 PK5129 5 Auxiliary Relay Rack (RP211) 1403 A-27 --- S R, M X X X --- --- E-11PK01 --- PK51 --- 0 E-13BM04 E-13BM06D E-13RP09 PK52 6 125 VDC Non-Class 1E 1403 A-27 --- S R, M, H X X X --- --- E-11PK02 --- PK0211 --- 0 Distribution Switchboard PK5200 6 125VDC Non-Class 1E Distr 1403 A-27 --- S R, M, H X X X --- --- E-11PK02 --- PK0211 --- 0 Attachment 1 Swbd Incoming Fdr PK5213 6 Reverse Isolation Relay Rack 1403 A-27 --- S R, M, H X X X --- --- E-11PK02 --- PK52 --- 0 (RP331)

PK61 5 125VDC Non-Class 1E 1403 A-27 --- S R, M, H X X X X --- E-11PK01 --- PK0106 --- 0 Distribution Switchboard PK6100 5 125VDC Non-Class 1E Distr 1403 A-27 --- S M X X X --- --- E-11PK01 --- PK0106 --- 0 Swbd Incoming Fdr PK6106 5 Transformer Protection Relay 1403 A-27 --- S R, M, H X X X --- --- E-13MR10 --- PK61 --- 0 Panel (MA104E) E-11PK01 PK6107 5 5KVA Process Control Inverter 1403 A-27 --- S M X X X X --- E-13SC12 --- PK61 --- 0 (PN01)

PK6108 5 Transformer Protection Relay 1403 A-27 --- S M X X X --- --- E-11PK01 --- PK61 --- 0 Panel (MA104F)

PK6115 5 Site Related Control Panel 1403 A-27 --- S R, M, H X X --- --- --- E-11PK01 --- PK61 Panel RL013/RL014 is included 1 (RL013/RL014) for a fire in areas C-9 and C-10 to de-energize the NB bus.

PK6116 5 ESF Control Panel 1403 A-27 --- S M X X X --- --- E-11PK01 --- PK61 --- 0 (RL017/RL018) Page 15 of 20 PK62 6 125VDC Non-Class 1E 4405 TURB --- S R, M, H X X X X --- E-11PK02 --- PK0206 --- 0 Distribution Switchboard

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

PK6200 6 125VDC Non-Class 1E Distr 4405 TURB --- S R, M, H X X X --- --- E-11PK02 --- PK0206 --- 0 Swbd Incoming Fdr PK6204 6 PA02 Breaker Control Power 4405 TURB --- S R, M, H X X X X --- E-13PA14 --- PK62 --- 0 CCN XX-E-013-004-CN008 (Outgoing Brkrs) E-11PK02 PK6205 6 PB04 Breaker Control Power 4405 TURB --- S R, M, H X X X X --- E-11PK02 --- PK62 If power not available, locally 0 E-13AE20 open PB0406 E-03PB13 PK6216 6 Transformer Protection Relay 4405 TURB --- S R, M, H X X X --- --- E-13MR10 --- PK62 --- 0 Panel (MA104D) E-11PK02 0PL09J 5, 6 Switchyard Remote --- --- --- S R, M, H X X --- --- --- E-1005-SY01 --- --- Panel 0PL09J is included for a 1 Supervisory Cabinet fire in areas C-9 and C-10 to de-energize the NB bus.

PN01 5 5KVA Process Control Inverter 1403 A-27 --- S M X X X X --- E-13SC12 --- PG19GAF1 --- 0 PK6107 PN02 6 5KVA Process Control Inverter 1403 A-27 --- S M X X X X --- E-13SC12 --- PG20GAF2 --- 2 PK4207 Attachment 1 PN07 5 120VAC Non-Class 1E 3409 C-16 --- S H X X X --- --- E-13PN01A --- PN07B --- 0 Distribution Switchboard E-13RL01 PN0712 5 Non Class 1E 120 VAC Inverter 3409 C-16 --- S H X X X --- --- E-13PN01A --- PN07 Needed for MSIV failure, fire in A- 3 PN09 15 or A-23 XX-E-013-002-CN016 PN0736 5 ESF Control Panel 3409 C-16 --- S H X X X --- --- E-13PN01A --- PN07 --- 0 (RL017/RL018)

PN0738 5 Reactor Auxiliary Control Pnl 3409 C-16 --- S H X X X --- --- E-13PN01A --- PN07 --- 0 (RL021/RL022)

PN07A 5 Voltage Regulator Panel - 3409 C-16 --- S H X X X --- --- E-13PN01A --- XPN07D --- 0 22.5KVA PN07B 5 Auto Transfer Switch 3409 C-16 --- S H X X X --- --- E-13PN01A --- XPN07B --- 0 PN07C 5 Voltage Regulator Panel - 3409 C-16 --- S H X X X --- --- E-13PN01A --- XPN07A Added per CCN-XX-E-013-000- 1 22.5KVA CN001 PN08 6 120VAC Non-Class 1E 3403 C-15 --- S H X X X --- --- E-13PN01 --- PN08B --- 0 Distribution Switchboard E-13RL01 PN0806 6 Non Class 1E 120 VAC Inverter 3403 C-15 --- S H X X X --- --- E-13PN01 --- PN08 Needed for MSIV failure, fire in A- 3 PN10 15 or A-23 XX-E-013-002-CN016 Page 16 of 20 PN0833 6 ESF Control Panel 3403 C-15 --- S H X X X --- --- E-13PN01 --- PN08 --- 0 (RL017/RL018)

WE<s/^,yyyWEW&

dŽW<

WE<s/^,yyyWEW&

dŽW<

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

PN0835 6 Reactor Auxiliary Control Pnl 3403 C-15 --- S H X X X --- --- E-13PN01 --- PN08 --- 0 (RL021/RL022)

PN08A 6 Voltage Regulator Panel - 3403 C-15 --- S H X X X --- --- E-13PN01 --- XPN08D --- 0 CCN XX-E-013-004-CN008 22.5KVA PN08B 6 Auto Transfer Switch 3403 C-15 --- S H X X X --- --- E-13PN01 --- XPN08C --- 0 PN08C 6 Voltage Regulator Panel - 3403 C-15 --- S H X X X --- --- E-13PN01 --- XPN08A Added per CCN-XX-E-013-000- 1 22.5KVA CN001 PN09 5 Non Class 1E 120 VAC Inverter 3301 C-9 --- S R, H X X X --- --- E-13RP10 --- PK3303 Needed for MSIV failure, fire in A- 3 15 or A-23 XX-E-013-002-CN016 PN09A 5 Non Class 1E 120 VAC 3301 C-9 --- S R, H X X X --- --- E-13RP10 --- PK3303 Needed for MSIV failure, fire in A- 3 Distribution Switchboard 15 or A-23 XX-E-013-002-CN016 PN10 6 Non Class 1E 120 VAC Inverter 3302 C-10 --- S R, H X X X --- --- E-13RP10 --- PK0403 Needed for MSIV failure, fire in A- 3 15 or A-23 XX-E-013-002-CN016 PN10A 6 Non Class 1E 120 VAC 3302 C-10 --- S R, H X X X --- --- E-13RP10 --- PK0403 Needed for MSIV failure, fire in A- 3 Attachment 1 Distribution Switchboard 15 or A-23 XX-E-013-002-CN016 XPN07A 1, 5 480/120V Instr 3-Phase Xfmr 3409 C-16 --- S H X X X --- --- E-13PN01A --- NG01ABF1 Revised per CCN-XX-E-013-000- 1 from NG01A CN001 and DCP 09803 XPN07D 5 480/120V Instr Xfmr from 3409 C-16 --- S H X X X --- --- E-13PN01A --- PG19GFR3 --- 0 PG19G (Alt. Feed)

XPN08A 4, 6 480/120V Instr 3-Phase Xfmr 3403 C-15 --- S H X X X --- --- E-13PN01 --- NG02ADF1 Revised per CCN-XX-E-013-000- 1 from NG02A CN001 and DCP 09803 XPN08D 6 480/120V Instr Xfmr from 3403 C-15 --- S H X X X --- --- E-13PN01 --- PG20GER5 --- 0 PG20G (Alt. Feed)

QD01 1 Emergency Lighting - Control 3601 C-27 --- S --- X X X --- --- E-03QD01 --- NK51A --- 0 Room QD02 1 Emergency Lighting - Control 3601 C-27 --- S --- X X X --- --- E-03QD01 --- NK51A --- 0 Room QD03 1 Emergency Lighting - Control 3601 C-27 --- S --- X X X --- --- E-03QD01 --- NK51A --- 0 Room QD04 1 Emergency Lighting - Control 3601 C-27 --- S --- X X X --- --- E-03QD01 --- NK51A --- 0 Page 17 of 20 Room WEE^^^ŽŽZW^,yyyWEWE

^

WEE^^^ŽŽZW^,yyyWEWE

^

WEsŽW^,yyyWEWE



WEsŽW^,yyyWEWE



$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

QD05 1 Emergency Lighting - Control 3601 C-27 --- S --- X X X --- --- E-03QD01 --- NK51A --- 0 Room QD06 1 Emergency Lighting - Control 3601 C-27 --- S --- X X X --- --- E-03QD01 --- NK51A --- 0 CCN XX-E-013-004-CN008 Room QJS0001 6 CVCS Heat Tracing Transfer 1101 A-1 --- S R --- X --- X --- E-13QJ07 --- NG02A Required for OFN RP-017A to 3 Switch ensure alternate boration path.

XX-E-013-002-CN012 QJTE6244A 6 QJTS6251 Sensing RTD 1113 A-2 --- S R --- X --- X --- E-13QJ07 --- NG02A Required for OFN RP-017A to 3 ensure alternate boration path.

XX-E-013-002-CN012 QJTS6251 6 CVCS Heat Tracing 1113 A-2 --- S R --- X --- X --- E-13QJ07 --- NG02A Required for OFN RP-017A to 3 ensure alternate boration path.

XX-E-013-002-CN012 RL001 1, 4 Reactor Coolant & Support 3601 C-27 --- S R, M, H X X X --- --- E-13RL01 --- NK4119 XX-E-013-001-CN013 2 System MCB E-13RL02 NK4407 E-11NK01 E-11NK02 Attachment 1 RL002 1, 4 Reactor Coolant & Support 3601 C-27 --- S M X X X --- --- E-13RL01 --- NN0111 XX-E-013-001-CN013 2 System MCB E-13RL02 NN0212 E-11NK01 E-11NK02 RL003 1, 4 Reactor Control Main Control 3601 C-27 --- S R X X X --- --- E-13NN01 --- NN0113 XX-E-013-001-CN013 2 Board E-13SE01 NK4116 NK5410 RL005 1, 2, Turbine Generator & 3601 C-27 --- S R, M, H X X X --- --- E-13RL01 --- NK4409 XX-E-013-001-CN011 XX-E- 2 3, 4 Feedwater MCB E-13RL03 NK4206 013-001-CN013 E-11NK01 E-11NK02 RL006 1, 2, Turbine Generator & 3601 C-27 --- S R, M, H X X X --- --- E-13RL01 --- NK4206 XX-E-013-001-CN011 XX-E- 2 3, 4 Feedwater MCB E-13RL03 013-001-CN013 E-11NK01 E-11NK02 Page 18 of 20

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

RL022 1, 4 Reactor Auxiliaries Main 3601 C-27 --- S H X X X --- --- E-13RL01 --- NK4414 XX-E-013-001-CN013 2 Control Board E-13RL06 NK5109 E-11NK01 PN0738 CCN XX-E-013-004-CN008 E-11NK02 PN0835 RL023 1, 4 Turbine Generator & 3601 C-27 --- S R, M, H X X X --- --- E-13RL01 --- NK4411 --- 0 Feedwater MCB E-13RL07 RL024 1, 4 Turbine Generator & 3601 C-27 --- S R, M, H X X X --- --- E-13BM06A --- NK4411 XX-E-013-001-CN013 2 Feedwater MCB E-13RL01 E-13RL07 E-11NK01 E-11NK02 RL025 1, 4 Turbine Generator & 3601 C-27 --- S H X X X --- --- --- --- --- RL025 is included in the matrix 1 Feedwater MCB because controls and indication are mounted on the panel. The controls and indication do not receive power from RL025.

Revised per CCN-XX-E-013-000-CN005. Attachment 1 RL026 1, 4 Turbine Generator & 3601 C-27 --- S H X X X --- --- --- --- --- RL026 is included in the matrix 1 Feedwater MCB because controls and indication are mounted on the panel. The controls and indication do not receive power from RL026.

Added per CCN-XX-E-013 CN005.

RL027 1, 4 Turbine Generator & 3601 C-27 --- S H X X X --- --- --- --- --- RL027 is included in the matrix 0 Feedwater MCB because controls and indication are mounted on the panel. The controls and indication do not receive power from RL027 RP043 5 Process Control Rack - Group 3605 C-27 --- S M X X X --- --- E-13BB19 M-761-00140 PG19GCR218 --- 2 1 E-13BG10 M-761-00141 PN01 E^^^ŽŽ E-13SC03 M-761-00174 WE Page 19 of 20 E-13SC07 D WE E-13SC12 D

$33(1',; &$/&8/$7,2112;;(

3)66'&20321(17/,67 5(9,6,2112

6RUWHGE\6\VWHP&RPSRQHQW,' 3DJH

Description R Component Fire Instrument SSD Sprtd Hot Cold Normal Alt Schematic /

S/G Room P&ID Other Drawings Power Source Notes E ID Area Location Fun Fun Stdby Shdwn Shdwn Shdwn One Line V

RP047 5, 6 Process Control Rack - Group 3605 C-27 --- S M X X X --- --- E-13SC01 M-761-00142 PG20GBR219 --- 2 2 E-13SC07 M-761-00143 PN02 E^^^ŽŽ E-13SC12 D WE

CCN XX-E-013-004-CN008 D WE RP053AA 1 BOP Instrumentation Rack 3605 C-27 --- S H X X X --- --- E-13RP09 --- NN0116 --- 0 E-13NN01 NN0120 RP053AB 1 BOP Instrumentation Rack 3605 C-27 --- S H X X X --- --- E-13RP09 --- NN0116 XX-E-013-001-CN013 2 E-13NN01 NN0120 RP053AC 1 BOP Instrumentation Rack 3605 C-27 --- S R, M, H X X X --- --- E-13RP09 --- NN0116 --- 0 E-13NN01 NN0120 RP053BA 4 BOP Instrumentation Rack 3605 C-27 --- S H X X X --- --- E-13RP09 --- NN0416 --- 0 E-13NN01 NN0418 RP053BB 4 BOP Instrumentation Rack 3605 C-27 --- S H X X X --- --- E-13RP09 J-110-005592 NN0418 --- 0 E-13NN01 J-110-00593 J-110-00596 RP053BC 4 BOP Instrumentation Rack 3605 C-27 --- S R, M, H X X X --- --- E-13RP09 --- NN0416 --- 0 E-13NN01 NN0418 RP053DA 2 BOP Instrumentation Rack 3605 C-27 --- S R, M, H X X X --- --- E-13RP09 --- NN0208 --- 0 Attachment 1 RP053DB 3 BOP Instrumentation Rack 3605 C-27 --- S R, M, H X X X --- --- E-13RP09 --- NN0307 --- 0 RP060 5, 6 Master Supervisory Station 3605 C-27 --- S R, M, H X X --- --- --- E-1005-SY01 --- PK5113 RP060 is used to open 1 (Also 1PM01J) switchyard breaker 13-8 if a fire occurs in areas C-9 or C-10.

RP068 1, 4 Miscellaneous BOP Control 3605 C-27 --- S R, M, H X X X --- --- E-K3GD01 --- NG01ACR142 --- 0 Panel E-K3GD01A NG02ACR136 E-11NG21 RP118A 1, 3 Auxiliary Shutdown Panel 1413N A-28 --- S R, M, H X X X --- --- E-13AB20A J-110-00216 NN0116 RP118A is used during alternate 2 E-13BG36 J-110-00220 NN0307 shutdown to attempt to close J-110-00584 steam dumps ABPV001 and J-110-00587 ABPV003 and open auxiliary J-110-00588 feedwater valves ALHV-7 and J-110-00591 ALHV-12. Use of RP118A is prudent but not required. XX-E-013-001-CN004 Page 20 of 20

FORM APF 05F-001-01, REV. 06 PAGE 1 OF 3 CALCULATION VERIFICATION REPORT DOCUMENT NO. XX-E-013-004-CN008 REV. N/A DOCUMENT TITLE: POST-FIRE SAFE SHUTDOWN (PFSSD) ANALYSIS ORIGINATOR: Brian Fox DESIGN VERIFIED: SAFETY CLASSIFICATION: VERIFICATION METHOD:

PRELIMINARY SAFETY-RELATED DESIGN REVIEW FINAL SPECIAL SCOPE ALTERNATE CALCULATION REVISION NON-SAFETY RELATED TESTING INDIVIDUAL VERIFICATION SIGNATURE: DATE: _07/22/2020_____

Print / Sign QUALIFICATION REQUIRED: ES9280479 TEAM VERIFICATION SIGNATURE: DATE:

Scope Verified:

TEAM LEADER SIGNATURE: DATE:

QUALIFICATION REQUIRED ES9280479 PRINT / SIGN

  • Team leader signature certifies that adequate interfaces and overlaps have occurred.

OVERVIEW (PURPOSE AND SCOPE):

The PFSSD interface with the NSSS includes certain functions that could cause spurious operation of the pressurizer Power Operated Relief Valves (PORVs), pressurizer normal spray valves and letdown isolation valves. For PFSSD, these valves are required to be closed. Proper identification of credited PFSSD power sources and components also included in scope.

CRUCIAL AREAS:

1. The PFSSD interface with the NSSS includes certain functions that could cause spurious operation of the pressurizer Power Operated Relief Valves (PORVs), pressurizer normal spray valves and letdown isolation valves. For PFSSD, these valves are required to be closed.
2. PFSSD credited power source identification and configuration.
3. PFSSD components identification and attributes.

FORM APF 05F-001-01, REV. 06 PAGE 2 OF 3 CALCULATION VERIFICATION REPORT DOCUMENT NO. XX-E-013-004-CN008 REV. N/A ALTERNATE OR INDEPENDENT ITEMS USED FOR VERIFICATION:

1. WIP-E-15000-067-BT-1
2. WIP-E-1F9301-005-A-1
3. WIP-E-1F9304-002-A-1
4. WIP-E-1F9421-007-A-1
5. WIP-E-1F9422C-003-A-1
6. WIP-E-1F9424E-006-A-1
7. WIP-E-1F9910-016-A-1

FORM APF 05F-001-01, REV. 06 PAGE 3 OF 3 CALCULATION VERIFICATION REPORT DOCUMENT NO. XX-E-013-004-CN008 REV. N/A COMMENTS: ORIGINATORS RESPONSE:

1. Appendix 1 p22. Following sounds unresolved, why not Resolved as noted in originators comments.

include the evaluation determination here? E-1F9910 impact will/should address this.

"SLIM stations included in the PFSSD design to evaluate whether they can be used to close spray valves if spuriously open" This is regard to Operator interface to the normal pressurizer Small Loop Interface Modules (SLIM) BBPK0455B &

BBPK0455C. Final E-1F9910 evaluation determined fire area needed to rely on need for SLIMS to close spray valves, thereofore BBPK0455B & BBPK0455C were removed as PFSSD components.

2. Appendix 3, p114 - PN031002 located in Room 3501, Fire Agreed. Corrected.

Area C-21 (Lower Spreader) inside distibution panel PN310.

Likewise PN041001 in room 3801, Area C-22.

3.

CONCLUSIONS:

Comments adequately address. CCN provides sufficient technically justification for the determination that the 7300 Controls upgrade is not adverse to PFSSD, including closure assurance of Pressurizer Power Operated Relief Valves (PORVs), pressurizer normal spray valves and letdown isolation valves. The population of required PFSSD components is sufficiently addressed.