Equipment Qualification Summary Document, Master List Section II, EQSD-II, Rev 28, Part 1
ML17151B044
Person / Time
Site: Wolf Creek 
Issue date: 03/02/2017
From:
Wolf Creek
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17151A982 List: ... further results
References
WO 17-0045 EQSD-II, Rev 28
Download: ML17151B044 (41)


Text

Revision 28 Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 EQ PROGRAM MASTER LIST (Table 1)

Plus Mild Environment SR Electrical Equipment List (Table 2)

Revision History I

Description I See Revision Summary

~

~

3/2117 Prepared by:

Brian Masters Date:

Qualification Required: ES9280907 Verified by:

l~ft C!*r!f~

Date:

3/2/17 Qualification Required: ES9280907 Approved by: ~~

Jeff Suter Date:

03/2/2017 Document Service Release by:

Date:

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT E SD-II, MASTER LIST SECTION II EQSD-11, MASTER LIST 1.0 PURPOSE The EQUIPMENT QUALIFICATION (EQ) MASTER LIST SYSTEM is used to maintain listings of components at WCGS requiring qualification and the maintenance contingencies required to meet those qualifications. It is noted that the Engineering Information System (EIS) and MPAC maintenance databases can be used to identify components that are in the EQ program.

Table 1:

List safety related electrical components that are located in a harsh environment and are required to have an EQ program document. This equipment is required to function during an accident and is identified as Category "A" or "B" in the LOCAl HELB/ MSLB fields.

Table 2:

List of safety related electrical components that are either located in a mild environment or not required to function during a design bases accident (DBA). These components while still needing to be qualified are not required to have an EQ program document and is identified as Category "C" or "D" in the LOCAl HELB/ MSLB fields.

2.0 FIELDS USED:

The fields identified below that are underlined are only used in Table 1. This additional information is not necessary for the equipment not required to have an EQ program document.

The EQ program documents are either an Equipment Qualification Work Package (EQWP) or the new electronic version Plant Qualification Evaluation (PQE).

Component Number:

The number used to identify the equipment that is to be created, updated and deleted to track the EQ program activities.

MC: (Maintenance Contingency required)

Those components that require an EQ program qualified replacement preventive maintenance (PM) activity to replace the component are identified with a "Yes" (Y). Equipment qualified longer for longer than 60 years of the life of the plant are identified with a "No" (N). Equipment qualified for less than 60 years but has been replaced such that the qualified life now extends past the 60 years of the life of the plant may also be identified as an "N". Those components that are listed with a "Y" are identified in EQSD-111 "Component Maintenance Replacement Information Sheet" document.

Equipment Qualification

Description:

The description of the component Installed Elevation:

Additional information on the location of the equipment, this includes the building, level and area (BLA) identifier to help locate the equipment.

EQ Room:

The room environment the equipment is installed in. Environmental conditions (temperature, pressure, humidity, radiation and flooding) are identified in EQSD-1, Attachment A and B.

EQ Spec:

On Table 1 the identified specification what is use to find the applicable EQWP or PQE program document. On Table 2 it is the associated specification that the equipment was bought to.

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II Model#:

The installed part number Manufacturer:

The name of the manufacture for the model number identified LOCA:

Describes the mode in which the component is to function when there is a loss of coolant accident.

HELB:

Describes the mode in which the component is to function when there is a high energy line break.

MSLB:

Describes the mode in which the component is to function when there is a main steam line break.

System:

The system the equipment is part of for more detail on the system go to the system description.

HOT/ COLD:

HOT SHUTDOWN specifies that the component is required for hot shutdown.

COLD SHUTDOWN specifies that the component is required for cold shutdown.

Notes:

Specifies the number of the note at the end of the list that is related to the component 3.0 EQSD-11, General Notes Section The notes in this section are applicable to both Table 1 and Table 2. It is noted that there are additional notes that are provided at the end of each table. Those notes are typically specific notes to the equipment for that table.

General Notes Applicable to All of EQSD-11 Tables 1 and 2:

A. The Hot and Cold Shutdown designations are based on a normal shutdown assuming a loss of offsite power and a safe shutdown earthquake. Components located in a harsh environment which are required for safe shutdown as a result of a LOCA, MSLB, or HELB are identified as Category A or B in this table.

B. The normal and accident environment temperature, pressure, radiation, humidity and spray information can be found in EQSD-1 Attachments A and B under the room number the equipment is located in.

C. A suffix (i.e. "-E01n or "-E02") has been added to some component numbers to allow additional EQ information related to the component to be listed in the table. This additional information may include subcomponents qualified to a different Equipment Qualification Work Package (EQWP) or, in some cases, identifies an approved alternative component (for example, a Barton and a Rosemount gauge approved for the identified component application).

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Table 2 Incorporated EQSD-11-26-01 The identified components were NN015 CP 12514 added the identified safety related added to Table 2 as identified in the NN016 electrical equipment to mild environment rooms subject change notice, with NK079 3301 and 3302.

exception that the system identifier NK080 for NN015 and NN016 was change from "NK" to "NN".

Table 1 Incorporated second part of EQSD-11-27-01 and Each component has a qualified life ABZS0048 Incorporated EQSD-11-27-02 of 60 years so maintenance ABZS0049 contingency is marked "N", the ABHV0048-E01 specification has changed to reflec ABHV0049-E01 EQWP-J-601A originally identified all of these the new PQE and all other fields components are all qualified due to a Cat. "A" for not in Table 2 have been identified.

MSLB. CP 05018 removed the solenoids from the EQ program, but did not remove these components. The Namco limit switches are now qualified by PQE-NAMCO-P01 and the Buchanan terminal blocks are qualified under PQE-E-093-P03. These Table 1 Incorporated first part of EQSD-11-27 -01 Changed the maintenance/

BBZS8026 replacement requirements from N BBZS8702AA During the revision of EQSD-111 it was noticed that to Y to incorporate change notice BBZS8702AB the EQ maintenance contingency for replacement EQSD-11-27-01.

BGZS8160 of the top cover gasket on NAMCO EA-180 limit EJZS8701BA switches were not previously listed in EQSD-111 as EJZS8701BB a result of the qualified life being more than 40 EJZS8825 years. However, since anytime the covers are EJZS8890B removed it is an EQ requirement to replace them a EMZS8823 maintenance activity needs to be shown in the EMZS8824 EQSD-111 and they are. Because these EMZS8843 maintenance activities were added to those EMZS8881 components in EQSD-111, the components listed in EPZS8808AB the attached table need the maintenance EPZS8808DB requirements column to be updated accordingly GTZS0005 per EQWP HE-3-6 to show a "Y".

GTZSOOO?

GTZS0008 GTZS0011 HBZS7126 HBZS7176 Cover Sheet, pages This document was missing some information that Added Scope and field usage 2&3 describes what was in the EQSD-11. Clarification sections plus provided additional as to what Table 1 and Table 2 is also needed to clarification about the difference be provided.

between the notes in the front and the back. WCNOC-42 is superseded by EQSD-11.

Revision 28 Items Affected Table 1 & Table 2

27XQB01, 27XQB02, 3XAP02 3XEG21, 3XEG23, 3XGS23, 45XJE01,
63XFC15, 63XFC17, 74XBG03, 74XEJ05, 95XGK07 Table 1 62TDDAL01 62TDEEN1 62TDEGN11 62TDEGN13 62TDENB01 62TDENB02 62TDENB05 62TDENB06 Table 1 62TDEEN2 Table 1 3XEJ07 Table 1 LFLE0009A, 98, 10A, 108, 101A, 1018, 102A, 1028 103A 1038, 104A &

1048 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD*II Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Reason for Change PQE~E~093-P01, Revision 2, Attachment 5 indicates that the subject relays are not required to operate during a DBA. Therefore, these switches were removed from the Table 1, EQSD-11. EIS shows these relays as not being in the EQ program.

E-11 012 page 29 and 33 identifies that the relays listed for 62TDDAL01, 62TDEEN1 and 62TDEGN11 are 237XBX120NE, 236ABX139NE and 236A8X 138NE relays respectively.

62TDEGN13, 62TDENB01, 62TDENB02, 62TDENB05 and 62TDENB06 are identified in E-11 0012 to be "NE" type relays so this has been added to the end of the model number (Ref PQE-E-093-P01).

E-13EN01 R/6 and E-11012, page 35 identifies that this relay is located in in RP333 not RP332. EIS currently shows this as not being EQ component.

CP 06187 modified this circuit and made relay 3XEJ07 a spare relay in panel RP209, this is reflexed in drawing E-11012 page 10 (item 34).

The EQSD-11 R/27 model number identified of either XM-60076 or XM-60077 is actually a Delaval GEMS P/N not model number and is not the correct number for all of these components. The correct model number is identified in EQWP-J-481 in enclosure 1, Table 1 and as shown in J-481-00039, paqe 22.

Changes Made Changed HELB, LOCA and MSLB classification to C and moved to table 2 of the EQSD-11.

Changed the model numbers and added "NE" to match what is shown in E-11 012 drawing as identified.

Identified relay is located in RP333 and deleted relay from EQSD-11 Table 1 because RP333 is in mild environment room 1408. The relay is now in Table 2 as part of RP333 like all the other mild environment relay applications in that panel.

Deleted relay 3XEJ07 from EQSD-11 Table 1 because it is a spare in place. Spares are not put in Table

2.

EIS updated to reflect thisais a spare, the EQ fields already updated.

Changed the model number to:

XM-54852 - {9A & 1 OA)

XM-54853 - (98, 108, 101 B, 1028, 1038 & 1048)

XM-54854- {101A, 102A, 103A &

104A)

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Table 1 The following NP8320A ASCO solenoid valve Updated all the component ABHY0012A applications qualification information was moved specification to M-237.

ABHY0012B from the EQWP-J-601A to PQE-M-237-P02 to ABHY0015A include all of the same model numbers together ABHY0015B under one qualification package. In addition ABHY0018A GKHY0184E ASCO valve model number ABHY0018B WPHCX8320A182E was moved from EQWP-M-ABHY0021A 627 A to PQE-M-237 -P02 for the same reasons.

ABHY0021B ABLY0007A ABLY0007B ABLY0008A ABLY0008B ABLY0009A ABLY0009B ABLY0010A ABLY0010B EFHY0043 EFHY0044 KAFY0029 GKHY0184E BBHV8026-E01 The following 601-JJ, 602-JJ, 604-JJ Kulka Updated all the component BBHV8027-E01 terminal blocks qualification information was specification to E-0358.

BGHV8160-E01 moved from the EQWP-E-028 to PQE-E-035B-P02 EJHCV8825-E01 to include all of the same model numbers together EJHCV8890A-E01 under one qualification package.

EJHCV8890B-E01 EMHV8823-E01 EMHV8824-E01 EMHV8843-E01 EMHV8871-E01 EM HV8881-EO 1 HBHV7176-E01 ZNI296 ZNI297 ZNI298 ZSI215 ZSI216 ZSI217

Revision28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-H, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Table 1 The following NQB Buchanan terminal blocks were Updated all the component ABHV0005-E01 moved from the EQWP-E-028 to PQE-E-093-P03 specification to E-093 and deleted ABHV0006-E01 to include them with the group all of them together the KAFV0029 line that was ABHY0012A-E01 under one qualification package.

referenced to the terminal block.

ABHY00128-E01 ABHY0015A-E01 The list also identified KAFV0029 for a "valve Deleted KAFV0029 line.

ABHY0015B-E01 Terminal Box, which is a duplicate of KAFV0029-Note: E/S database updated to ABHYOO 18A-EO 1 E01. KAFY0029 still exists for the ASCO solenoid change this component not be an ABHY00188-E01 valve.

EQ component and LOCAl HELBI ABHY0021A-E01 MSLB fields being an "E".

ABHY00218-EO 1 ABLY0007A-E01 ABL Y00078-E01 ABL Y0009A-E01 ABL Y00098-E01 ABPV0001-E01 ABPV0002-E01 ABPV0003-E01 ABPV0004-E01 BGHV8152-E01 BLHV8047-E01 BMHV0001-E01 BMHV0002-E01 BMHV0003-E01 BMHV0004-E01 BMHY0001 B-E01 BMHY00028-E01 BMHY0003B-E01 BMHY0004B-E01 BNHCV8800A-E01 BNHCV8800B-E01 EFHV0043-E01 EFHV0044-E01 EMHV8888-E01 EMHV8964-E01 EPHV8880-E01 HBHV7136-E01 HBHV7150-E01 KAFV0029 KAFV0029-E01 LFFY0096A-E01

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Table 1 SCA-02-0047 has downgraded the solenoid shell Deleted the identified components BMHV0019 and coil assembly to non-safety related for the from Table 2.

BMHV0020 solenoid valves listed as documented in PQE-J-BMHV0021 603A-P01. Therefore, there are no longer any EQ Note: E/S database updated to BMHV0022 requirements associated with the solenoid shell change this component not be an BMHV0035 and coil assemblies and required maintenance EQ component and LOCAl HELBI BMHV0036 contingencies (EQCN EQWP-J-603A-05-09).

MSLB fields being an "E".

BMHV0037 Since the components are now NSR they have not BMHV0038 been included into Table 2.

BMHV0065 BMHV0066 BMHV0067 BMHV0068 Table 1 Per EQWP-E-029 R/6 all the E-029 SR motor Change model number column to DPBG05A-E01 affected have been changed to EGS splice kits include the EGS P/N 3.99.16-DPEN01A-E01 except for these three motors, which are approved 3x250MCM-HVNS (EGS) kit as an DPEN01 B-E01 to go to the EGS splice kit the next time it needs option for the installed Kerite kit changed. Thus the Kerite splice kit is what is model number DS-7445.

currently installed and it is still addressed by EQWP-E-029 R/6 when it is changed to the EGS Change the manufacture column to splice kit it will be qualified by PQE-E-029-P02.

show Kerite/ EGS (option).

Table 1 PQE-E-035-P01 has been completed to replace Change the "Y" to a "N" in the "MC" ZNE268 EQWP-E-035 and the qualified life of the subject column for the identified ZNE269 penetration components has been determined to components.

ZNE277 be at least 60 years. As a result there is no longer ZNE278 a need for any maintenance contingency to replace ZNE279 any of the parts in an EQ qualified life PM.

ZNE287 ZNE288 ZNE295 ZNE296 ZNE297 ZNE298 ZSE215 ZSE216 ZSE217 ZSE218 ZSE219 ZSE233 ZSE234 ZSE243 ZSE249 ZSE250 ZSE258

Revision28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made GTHZ0004 The original EQWP-M-237 talked about the Fisher The identified components have GTHZ0005 Valve Assembly: 18" Type 9220, Bettis Actuator: T-been removed from EQSD-11 table GTHZ0006 416B-SR3-12 and did not qualify them other than 1 and since they are mechanical GTHZ0007 to identify that the valves are part of the actuators they have been not be GTHZOOOB mechanical qualification program. These actuators added to Table 2 either.

GTHZ0009 are pneumatic actuator, not electrical components GTHZ0011 and are a part of the mechanical valve. The EIS has been updated to uncheck GTHZ0012 mechanical qualification program is not included in the EQ field and show LOCN the EQ program at Wolf Creek and as such the HELBI MSLB fields as being "E".

identified valves should not be included in EQSD-11.

BB004A-E02 EQWP-J-565 states the qualified life for the Changed to MC column in EQSD-11 BB0048-E02 following components is greater than 60 years and from "Y" to "N".

thus the MC column should be "N", but was missed when the other components on the EQWP were updated.

ABHV0011 The identified component originally was used to Deleted the subject components ABHV0014 track the EQ component qualification. DCP 09552 from EQSD-11 Table 1.

ABHV0017 replaced the original components and created new ABHV0020 component numbers to track the components AEFV0039 required to be qualified in the EQ program. PQE-AEFV0040 M-630-P01 does not have any maintenance AEFV0041 requirements for these asset tags. There is a AEFV0042 maintenance requirement against the-MV1/2/3/4/5/6 asset and is listed in the PQE and EQSD-111 as such. For example ABHV0011-MV1 (change arion stem seal). Thus the identified valves only address mechanical aspects of the valves now and mechanical equipment is not addressed by the EQ program at Wolf Creek.

Based on that the subject components do not need to be listed in EQSD-11 Table 1 or 2.

Revision 28 EQUIPMENT UALIFICATION

SUMMARY

DOCUMENT EQSD-11, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made ABHV0011-MV1 DCP 09552 replaced the M-628 equipment with The specification identified for the ABHV0011-MV2 equipment that was purchased under specification components identified has been ABHV0011-MV3 M-630. PQE-M-630-P01 addresses the changed from M-628 to M-630.

ABHV0011-MV4 qualification of the replacement equipment.

ABHVOO 11-MV5 ABHV0011-MV6 ABHV0014-MV1 ABHV0014-MV2 ABHV0014-MV3 ABHV0014-MV4 ABHVOO 14-MVS ABHV0014-MV6 ABHV0017-MV1 ABHV0017 -MV2 ABHV0017-MV3 ABHV0017-MV4 ABHV0017 -MV5 ABHV0017-MV6 ABHV0020-MV1 ABHV0020-MV2 ABHV0020-MV3 ABHV0020-MV4 ABHV0020-MV5 ABHV0020-MV6 EJFIS0611 As identified in EQWP-ESE-40A and PQE-J-301-Changed MC field from "N" to "Y" to EJLT0007 P01 the subject equipment has replacement match the EQSD-IIIIist and EJLT0008 frequencies that require a qualified life replacement identified PQEs.

and the MC field needs to be a "Y".

RP209 The EQ program components in these panels are Change the MC field from "Y" to RP330 the relays identified in PQE-E-093-P01. When the "N".

RP332 subject PQE was complete it was confirmed that based on the frequency and the fact that the relays had been confirmed to have been replaced with "NE" type relays and the time remaining being less the identified qualified life the relay no longer need a maintenance contingency. Most of the relays had their own PM file; however, in just a few cases there were more than one relay that was done in a group under these panel numbers that are no lonQer needed.

ZZQ-1-EQ Additional review of the commodity equipment Added new component number ZZR-1-EQ numbers used to track the EQ specification E-ZZY-3-EQ. Updated description, ZZV-1-EQ 01013 EQ program qualification documents the EQ Spec and Model# fields to ZZW-1-EQ model numbers and descriptions need to be match what is identified in the ZZY-1-EQ updated to better reflect the new PQE document identified PQEs.

ZZY-2-EQ ties. This including identifying those models that ZZY-3-EQ (new) are the old part number and material and in the EQ ZZZ-1-EQ Spec field specifically tying the model number to ZZZ-2-EQ the applicable PQE.

ZZZ-3-EQ

Revision 28 EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made 3XBM13 Based on PQE-E-093-P01 Attachment 5 list of Added applicable component 3XBM14 energized or de-energized relays identified the number to the end of the equipment 3XBM15 component number the relay is applicable to.

qualification description field.

3XBM16 3XBM17 3XBM18 3XBM19 3XBM20 3XBM42 3XBM43 3XBM44 3XBM45 3XEG20 3XEJ01 3XGE05 3XGE07 3XGE09 3XGE11 3XGE13 3XGE15 3XGK16 3XGK17 95XGE01 Note 27 (Table 1 Room 1130 is connected to the other rooms in the Added room 1130 to the note.

and Table 2) note per review of drawing 1 0466-A-1301. No SR electrical equipment in room 1130 to apply the note.

Note 30 (Table 1 Room 1119 and 1321 are not connected to the Deleted rooms 1119 and 1321 from and Table 2) other rooms in the note per review of drawing the note.

1 0466-A-1302.

Note 31 (Table 1 &

Room 1127 is not part of rooms 1508 and 1509, Deleted room 1127 from note 31 Table 2) except for the isolation dampers.

and remove it from EGFT0062.

EGFT0062.

Note 33 (Table 1 Room 1401is connected to the other rooms in note Added room 1401 to the note and and Table 2) 33 per review of drawing 1 0466-A-1301. There is included the note in all the DPEG01B some SR electrical equipment in room 1401 listed identified components that are in DPEG01D on Table 2 only, these need note 33 identified in RM 1401 on Table 2.

DSGL 118 the notes section.

EFHV0052 EFHV0060 EGHV0012 EGHV0014 EGHV0054 EGPT0078 EGTE0032 EGTV0030 EGTV0030-E01 EGTY0030A EGZS0030 GLHIS0023

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Note 34 {Table 1)

Rooms 1504, 1506 and 1513 are part of the other Added rooms 1504, 1506 and 1513 GEHZ0101 room due to transfer grill GLD0175 shown on M-to the note and included the note in GEHZ0102 1H1431.

all the identified components that GFHZ0020 are in RM 1504, 1506 and 1513 on GFHZ0021 Table 1.

GKHY0184E GKHZ0150 GKHZ0151 GKHZ0184E GLHZ0013 GLHZ0014 GSHV0012 GSHV0030 GSHV0032 GTHY0004 GTHY0006 GTHZ0026 GTHZ0027 GTZS0004 GTZS0006 SGS02A

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Note 34 (Table 2)

Rooms 1504, 1506 and 1513 are part of the other Added rooms 1504, 1506 and 1513 GEHZ0103 room due to transfer grill GLD0175 shown on M-to the note and included the note in GEHZ0104 1H1431.

all the identified components that GFHZ0022 are in RM 1504, 1506 and 1513 on GFHZ0023 Table 2.

GKAE0002 GKAE0003 GKAT0002 GKAT0003 GKHY0013D GKHY0184C GKHY0184D GKHZ0013D GKHZ0152 GKHZ0153 GKHZ0154 GKHZ0155 GKHZ0184C GKHZ0184D GKRE0004 GKRE0005 GKRT0004 GKRT0005 GLHZ0032-1 GLHZ0032-2 GLHZ0033-1 GLHZ0033-2 GTHZ0028 GTHZ0029 GTRE0032 GTRT0032 GTRV00228 GTRV00338 RP289 SGS03A SP104A SP104B SP105A SP1058 SP132A SP132B Note 37 (Table 1 Reference E-0358-00050, Table 3.1, page 11 Add note 37 to table 1 and included only) provides specific information on which modules the note in all the identified ZNE-1-EQ use the Conax modules in the Bunker-Ramo components.

ZNI-1-EQ assemblies and those that are power, control or ZSE-1-EQ instrumentation ones are identified. This is done to ZSI-1-EQ aid the users of this document with the information from PQE-E-035B-P01 research.

Revision28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Note 38 (Table 1 In the penetrations Kulka terminal blocks are used Add note 38 to table 1 and included only) except on SR instrumentation circuits. Putting all the note in all the identified ZNE-1-EQ the information needed in the model number components.

ZNE268 column would have made the line to long.

ZNE269 However, needed to provide the user the model ZNE277 numbers so the information all put in note 38 so it ZNE278 could be identified to the penetrations component ZNE279 numbers.

ZNE287 ZNE288 ZNE295 ZNE296 ZNE297 ZNE298 ZNI-1-EQ ZNI268 ZNI269 ZNI277 ZNI278 ZNI279 ZNI287 ZNI288 ZNI295 ZSE-1-EQ ZSE215 ZSE216 ZSE217 ZSE218 ZSE219 ZSE233 ZSE234 ZSE243 ZSE249 ZSE250 ZSE258 ZSI-1-EQ ZSI218 ZSI219 ZSI233 ZSI234 ZS1243 ZSI249 ZSI250 ZSI258 Note 11 (Table 2 Calculation XX-81 provides the location specific Added XX-81 to the note.

only) dose calculation for EGHV0069A, EGHV0069B, EGHVOO?OA. EGHV0070B and EJFIS0610, which provides helpful information on the bases for the components being in Table 2.

Revision28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Revision 28 Cover Sheet (Continuation Sheet)

Revision Summary Items Affected Reason for Change Changes Made Note 12 (Table 2 Calculation XX-53 provides the location specific Added XX-53 to the note.

only) dose calculation NG001 B, NG001T, NG002B, NG002T, NG003T and NG004T, which provides helpful information on the bases for the components being in Table 2.

Revision 28 EQUIPMENT QUALIFICATION

SUMMARY

DOCUMENT EQSD-II, MASTER LIST SECTION II EQSD-11 Change Notices Not Incorporated EQSD Change Sequence Number: EQSD-11 Date None

EQSD-11 Rev. 27 EQSD-11 Table 1:

1 of 51 EQ Harsh Environment Equipment List Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L

  • sHUT A B B DOWN 3XBM13 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 21 9BBX221 NE Struthers-Dunn A B D BM BOTH 16

{BMHV0001)

ELEV2000-0 30 3XBM14 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D BM BOTH 16 (BMHV0002)

ELEV2000-0 30 3XBM15 N AUX RELAY IN PANEL RP209 134AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D BM

  • BOTH 16 (BMHV0003)

ELEV 2000-0 30 3XBM16 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D BM BOTH 16 (BMHV0004)

ELEV2000-0 30 3XBM17 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D BM BOTH 16 (BMHV0065)

ELEV 2000-0 30 3XBM18 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D BM BOTH 16 (BMHV0066)

ELEV 2000-0 30 3XBM19 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D BM BOTH 16 (BMHV0067)

ELEV 2000-0 30 3XBM20 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D BM BOTH 16 (BMHV0068)

ELEV 2000-0 30 3XBM42 N AUX RELAY JN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A 8 D BM BOTH 16 (BMHV0065/ 66/ 67/ 68)

ELEV 2000-0 30 3XBM43 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D BM BOTH 16 (BMHV0065/66/67/68)

ELEV 2000-0 30 3XBM44 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D BM BOTH 16 (BMHV0065/66/67/68)

ELEV 2000-0 30 3XBM45 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D BM BOTH 16 (BMHV0065/66/67/68)

ELEV 2000-0 30 3XEG20 N AUX RELAY IN PANEL RP330 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D EG BOTH 17 (EGTV0029)

ELEV2000-0 30 3XEJ01 N EJHV0014 OPEN AND SEAL IN AUX 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D EJ BOTH 16 RELAY IN RP209 (EJHV0014)

ELEV 2000-0 30 3XEN03 N AUX RELAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D EN BOTH 18 ELEV 2000-0 30 3XGE05 N AUX RELAY PANEL RP332 (GEHZ01 01, 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GE BOTH 18 102, 103, 104)

ELEV 2000-0 30 3XGE07 N AUX RELAY PANEL RP332 (GEHZ01 01, 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GE BOTH 18 102, 103, 104)

ELEV 2000-0 30 3XGE09 N AUX RELAY PANEL RP332 (GEHZ0101, 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GE BOTH 18 102, 103, 104)

ELEV 2000-0 30 3XGE11 N AUX RELAY PANEL RP332 (GEHZ0101, 134 AUX BLDG/

1320 E-093 2198BX221NE Struthers-Dunn A B D GE BOTH 18 102, 103, 104)

ELEV 2000-0 30 3XGE13 N AUX RELAY PANEL RP332 (GEHZ0101, 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GE BOTH 18 102, 103, 104)

ELEV2000-0 30 3XGE15 N AUX RELAY PANEL RP332 (GEHZ01 01, 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GE BOTH 18 102, 103, 104)

ELEV2000-0 30

~-

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 2 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L SHUT A B B DOWN 3XGK16 N AUX RELAY PANEL RP330 (SGK04A) 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GK BOTH 17 ELEV 2000-0 30 3XGK17 N AUX RELAY PANEL RP330 (SGK05A ) 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GK BOTH 17 ELEV 2000-0 30 3XGN03 N AUX RELAY IN PANEL RP330 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GN BOTH 17 ELEV2000-0 30 3XGN05 N AUX RELAY IN PANEL RP330 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GN BOTH 17 ELEV 2000-0 30 3XGN07 N AUX RELAY IN PANEL RP330 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GN BOTH 17 ELEV2000-0 30 3XGN09 N AUX RELAY IN PANEL RP330 134 AUX BLDG!

1320 E-093 219BBX221NE Struthers-Dunn A B D GN BOTH 17 ELEV 2000-0 30 3XGS01 N AUX RELAY IN PANEL RP209 134 AUX BLDG!

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 16 ELEV2000-0 30 3XGS03 N AUX RELAY IN PANEL RP209 134 AUX BLDG!

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 16 ELEV 2000-0 30 3XGS05 N AUX RELAY IN PANEL RP209 134 AUX BLDG!

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 16 ELEV 2000-0 30 3XGS07 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 16 ELEV 2000-0 30 3XGS09 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A 8 D GS BOTH 16 ELEV2000-0 30 3XGS11 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 16 ELEV2000-0 30 3XGS13 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 16 ELEV 2000-0 30 3XGS15 N AUX RELAY PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 16 ELEV 2000-0 30 3XGS17 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 16 ELEV2000-0 30 3XGS19 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 16 ELEV2000-0 30 3XGS21 N AUX RELAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 16 ELEV 2000*0 30 3XGS25 N AUX RELAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 ELEV2000-0 30 3XGS27 N AUX RELAY PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 18 ELEV2000-0 30 3XGS29 N AUX RELAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 18 ELEV2000-0 30 3XGS31 N AUX RELAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 ELEV2000-0 30

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 3 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es c L L SHUT A B 8 DOWN 3XGS33 N AUX RElAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 ELEV2000-0 30 3XGS35 N AUX RElAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 18 ELEV 2000-0 30 3XGS37 N AUX RElAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 ELEV2000-0 30 3XGS39 N AUX RElAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 1 ELEV 2000-0 30!

3XGS41 N AUX RElAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 18 ELEV 2000-0 30 3XGS43 N AUX RElAY PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GS BOTH 18 ELEV 2000-0 30 3XGS45 N AUX RElAY IN PANEL RP332 134AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 ELEV 2000-0 30 3XGS47 N AUX RElAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 ELEV 2000-0 30 3XGS49 N AUX RELAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D GS BOTH 18 ELEV 2000-0 30 3XSJ01 N 120 VAC AUX RElAY IN RP209 FOR 134 AUX BLDG/

1320 E-093 219FXX114NE Struthers-Dunn A B D SJ BOTH 16 SJHV006, 13, 19 ELEV 2000-0 30 3XSJ03 N 120 VAC AUX RElAY IN RP209 FOR 134 AUX BLDG/

1320 E-093 219DXB119NE Struthers-Dunn A B D SJ BOTH 16 SJHV0006 ELEV2000-0 30 3XSJ05 N 120 VAC AUX RElAY IN RP209 FOR 134 AUX BLDG/

1320 E-093 21 9DXB119NE Struthers-Dunn A B D SJ BOTH 16 SJHV0006 ELEV2000-0 30 3XSJ07 N 120 VAC AUX RElAY IN RP209 FOR 134 AUX BLDG/

1320 E-093 219 DXB119NE Struthers-Dunn A B D SJ BOTH 16 SJHV0013 ELEV2000-0 30 3XSJ09 N 120 VAC AUX RElAY IN PANEL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D SJ BOTH 16 FOR SJHV0013 ELEV 2000-0 30 3XSJ11 N 120 VAC AUX RElAY IN RP209 FOR 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D SJ BOTH 16 SJHV0019 ELEV 2000-0 30 3XSJ13 N 120 VAC AUX RELAY IN RP209 FOR 134 AUX BLDG/

1320 E-093 219DXB119NE Struthers-Dunn A 8 D SJ BOTH 16 SJHV0019 ELEV 2000-0 30 3XSJ25 N AUX RElAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D SJ BOTH 18 ELEV 2000-0 30 3XSJ27 N AUX RElAY IN PNL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D SJ BOTH 18 ELEV 2000-0 30 3XSJ29 N AUX RElAY IN PNL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D SJ BOTH 18 ELEV 2000-0 30 3XSJ31 N 120 VAC AUX RELAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D SJ BOTH 18 FOR SJHV0128, 130, 131 ELEV 2000-0 30 3XSJ33 N 120 VAC AUX RElAY IN PANEL RP332 134AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D SJ BOTH 18 FOR SJHV0128 ELEV2000-0 30

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 4 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L SHUT A B B DOWN 3XSJ35 N 120 VAC AUX RELAY IN PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D SJ BOTH 18 FOR SJHV0128 ELEV 2000-0 30 3XSJ37 N 120 VAC AUX RELAY IN RP332 FOR 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D SJ BOTH 18 SJHV0131 ELEV 2000-0 30 3XSJ39 N 120 VAC AUX RELAY IN RP332 FOR 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D SJ BOTH 18 SJHV0131 ELEV 2000-0 30 62TDDAL01 N AUX RELAY IN PANEL RP330 134 AUX BLDG/

1320 E-093 237XBX120NE Struthers-Dunn A B D AL BOTH 17 ELEV 2000-0 30 62TDEEN1 N AUX RELAY IN RP332 134 AUX BLDG/

1320 E-093 236ABX139NE Struthers-Dunn A B D EN BOTH 18 ELEV 2000-0 30 62TDEGN11 N AUX RELAY IN PANEL RP330 134 AUX BLDG/

1320 E-093 236ABX138NE Struthers-Dunn A B D EG BOTH 17 ELEV2000-0 30 62TDEGN13 N AUX RELAY IN PANEL RP330 134 AUX BLDG/

1320 E-093 236ABX138NE Struthers-Dunn A B D EG BOTH 17 ELEV2000-0 30 62TDENB01 N NB01 DEGRADED VOLTAGE TRIP 134 AUX BLDG/

1320 E-093 236ABX139NE Struthers-Dunn A B D EN BOTH 18 RELAY (NB0112) IN RP332 ELEV 2000-0 30 62TDENB02 N NB01 DEGRADED VOLTAGE TRIP 134 AUX BLDG/

1320 E-093 236ABX139NE Struthers-Dunn A B D EN BOTH 18 RELAY (NB0109) IN RP332 ELEV2000-0 30 62TDENB05 N NB01 DEGRADED VOLTAGE 134 AUX BLDG/

1320 E-093 236ABX139NE Struthers-Dunn A B D EN BOTH 18 ANNUNCIATOR RELAY (NB0112) IN ELEV 2000-0 30 RP332 62TDENB06 N NB01 DEGRADED VOLTAGE 134 AUX BLDG/

1320 E-093 236ABX139NE Struthers-Dunn A B D EN BOTH 18 ANNUNCIATOR RELAY (NB0109) IN ELEV 2000-0 30 RP332 94XAB05 N AUX RELAY IN PNL RP209 134 AUX BLDG/

1320 E-093 219BBX221NE Struthers-Dunn A B D AB BOTH 16 ELEV 2000-0 30 95XGE01 N AUX RELAY PANEL RP330 (GEHZ0103) 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GE BOTH 17 ELEV2000-0 30 95XGE03 N AUX RELAY PANEL RP332 134 AUX BLDG/

1320 E-093 219BBX221 NE Struthers-Dunn A B D GE BOTH 18 ELEV 2000-0 30 95XKA004 N AUX RELAY IN RP332 134 AUX BLDG/

1320 E-093 2198BX221 NE Struthers-Dunn A B D KA BOTH 18 ELEV2000-0 30 ABHV0005-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1412 E-093 NOB. 616822 Buchanan (Amerace) C D A AB BOTH ELEV 2026-0 ABHV0006-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1412 E-093 NOB. 616822 Buchanan {Amerace) C D A AB BOTH ELEV 2026-0 ABHV0011 -MV1 Y LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-1 ELEV2026-0 ABHV0011-MV2 Y LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-2 ELEV 2026-0 ABHV0011-MV3 y LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-3 ELEV 2026-0

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 5 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es, C L L SHUT I

A B B DOWN ABHV0011-MV4 Y LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-4 ELEV2026-0 ABHV0011-MV5 Y LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-5 ELEV 2026-0 ABHV0011-MV6 Y LOOP 4 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-6 ELEV2026-0 ABHV0014-MV1 Y LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-1 ELEV 2026-0 ABHV0014-MV2 Y LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-2 ELEV 2026-0 ABHV0014-MV3 Y LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-3 ELEV 2026-0 ABHV0014-MV4 Y LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG!

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-4 ELEV2026-0 ABHV0014-MV5 Y LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-5 ELEV2026-0 ABHVOO 14-MV6 Y LOOP 1 MAIN STEAM ISO VALVE 145 AUX BLDG/

1508 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-6 ELEV 2026-0 ABHV0017-MV1 Y LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG!

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-1 ELEV 2026-0 ABHV0017 -MV2 Y LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-2 ELEV2026-0 ABHV0017 -MV3 Y LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-3 ELEV 2026-0 ABHV0017-MV4 Y LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-4 ELEV2026-0 ABHV0017-MV5 Y LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-5 ELEV2026-0 ABHV0017-MV6 Y LOOP 2 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-6 ELEV2026-0 ABHV0020-MV1 Y LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-1 ELEV 2026-0 ABHV0020-MV2 Y LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-2 ELEV2026-0 ABHV0020-MV3 Y LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-3 ELEV 2026-0 ABHV0020-MV4 Y LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-4 ELEV 2026-0 ABHV0020-MV5 y LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-5 ELEV 2026-0 ABHV0020-MV6 Y LOOP 3 MAIN STEAM ISO VALVE 145 AUX BLDG/

1509 M-630 MV-1 CCI A D A AB BOTH 31 CONTROL SOLENOID VALVE MV-6 ELEV2026-0

~

.. l.

EQSD-11 Rev. 28 Table 1: EO Harsh Environment Equipment List 6 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es 1 c L L SHUT A B B DOWN ABHV0048-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan {Amerace) c D A AB BOTH ELEV 2026-0 ABHV0049-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan (Amerace) c D A AB BOTH ELEV 2026-0 ABHY0012A y ABHV0012 SOLENOID VALVE 145 AUX BLDG/

1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0012A-E01 N VALVE TERMINAL BOX (ABZS0012A}

145 AUX BLDG/

1508 E-093 NQB. 616822 Buchanan (Amerace} A D A AB BOTH 31 ELEV2026-0 ABHY0012B Y ABHV0012 SOLENOID VALVE 145 AUX BLDG/

1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0012B-E01 N VALVE TERMINAL BOX (ABZS0012B) 145 AUX BLDG/

1508 E-093 NQB. 616822 Buchanan (Amerace) A D A AB BOTH 31 ELEV 2026-0 ABHY0015A Y ABHV0015 SOLENOID VALVE 145 AUX BLDG/

1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV2026-0 ABHY0015A-E01 N VALVE TERMINAL BOX (ABZS0015A) 145 AUX BLDG/

1508 E-093 NQB. 616822 Buchanan {Amerace) A D A AB BOTH 31 ELEV 2026-0 ABHY00158 Y ABHV0015 SOLENOID VALVE 145 AUX BLDG/

1508 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0015B-E01 N VALVE TERMINAL BOX {ABZS0015B) 145 AUX BLDG/

1508 E-093 NQB. 616822 Buchanan {Amerace) A D A AB BOTH 31 ELEV2026-0 ABHY0018A Y ABHV0018 SOLENOID VALVE 145 AUX BLDG/

1509 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0018A-E01 N VALVE TERMINAL BOX (ABZS0018A) 145 AUX BLDG/

1509 E-093 NQB. 616822 Buchanan {Amerace) A D A AB BOTH 31 ELEV2026-0 ABHY0018B Y ABHV0018 SOLENOID VALVE 145 AUX BLDG/

1509 M-237 NP8320A 187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0018B-E01 N VALVE TERMINAL BOX {ABZS0018B) 145 AUX BLDG/

1509 E-093 NQB. 616822 Buchanan (Amerace) A D A AB BOTH 31 ELEV 2026-0 ABHY0021A Y ABHV0021 SOLENOID VALVE 145 AUX BLDG/

1509 M-237 NP8320A 187E ASCO A D C AB BOTH 31 ELEV 2026-0 ABHY0021A-E01 N VALVE TERMINAL BOX {ABZS0021A) 145 AUX BLDG/

1509 E-093 NQB. 616822 Buchanan {Amerace) A D A AB BOTH 31 ELEV 2026-0 ABHY0021B Y ABHV0021 SOLENOID VALVE 145 AUX BLDG/

1509 M-237 NP8320A187E ASCO A D C AB BOTH 31 ELEV2026-0 ABHY0021 B-E01 N VALVE TERMINAL BOX (ABZS0021B) 145 AUX BLDG/

1509 E-093 NQB. 616822 Buchanan (Amerace) A D A AB BOTH 31 ELEV2026-0 ABLY0007A Y ABLV0007 SOLENOID VALVE 145 AUX BLDG/

1412 M-237 NP8320A189E ASCO A D C AB BOTH ELEV2026-0 ABL Y0007A-E01 N VALVE TERMINAL BOX (ABL YOOOSB) 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan {Amerace) A D A AB BOTH ELEV2026-0 ABLY0007B Y ABLV0007 SOLENOID VALVE 145 AUX BLDG/

1412 M-237 NP8320A 189E ASCO A D C AB BOTH ELEV 2026-0

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 7 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L SHUT A B B DOWN ABL Y0007B-E01 N VALVE TERMINAL BOX (ABL Y0008A) 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan (Amerace) A D A AB BOTH ELEV2026-0 ABLY0008A Y ABLV0008 SOLENOID VALVE 145 AUX BLDG/

1412 M-237 NP8320A189E ASCO A D C AB BOTH ELEV2026-0 ABLY0008B Y ABLV0008 SOLENOID VALVE 145 AUX BLDG/

1412 M-237 NP8320A189E ASCO A D c AB BOTH ELEV 2026-0 ABLY0009A Y ABLV0009 SOLENOID VALVE 145 AUX BLDG/

1411 M-237 NP8320A189E ASCO A D c AB BOTH ELEV 2026-0 ABL Y0009A-E01 N VALVE TERMINAL BOX (ABLY0010B) 145 AUX BLDG/

1411 E-093 NQB. 616822 Buchanan (Amerace) A D A AB BOTH ELEV 2026-0 ABLY0009B Y ABLV0009 SOLENOID VALVE 145 AUX BLDG/

1411 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABL Y0009B-E01 N VALVE TERMINAL BOX (ABLY0010A) 145 AUX BLDG/

1411 E-093 NQB. 616822 Buchanan (Amerace) A D A AB BOTH ELEV 2026-0 ABLY0010A Y ABLV0010 SOLENOID VALVE 145 AUX BLDG/

1411 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABLY0010B Y ABLV0010 SOLENOID VALVE 145 AUX BLDG/

1411 M-237 NP8320A189E ASCO A D C AB BOTH ELEV 2026-0 ABPT0001 Y STM GEN A STEAM LINE PRESSURE 135 AUX BLDG/

1304 J-301 1153GB9R Rosemount Nuclear A D D AB BOTH ELEV 2000-0 i

ABPT0004 Y STM GEN D STEAMLINE PRESSURE 135 AUX BLDG/

1304 J-301 1153GB9R Rosemount Nuclear A D D AB BOTH ELEV2000-0 ABPT0514 Y MAIN STEAM PRESSURE LOOP 1 145 AUX BLDG/

1411 ESE-1A 763 ITT Barton A D B AB BOTH ELEV2026-0 ABPT0515 Y MAIN STEAM PRESSURE LOOP 1 145 AUX BLDG/

1411 ESE-1A 763 ITT Barton A D B AB BOTH I

ELEV 2026-0 ABPT0516 Y MAIN STEAM PRESSURE LOOP 1 145 AUX BLDG/

1411 ESE-1A 763 ITT Barton A D B AB BOTH ELEV 2026-0 ABPT0524 Y MAIN STEAM PRESSURE LOOP 2 145 AUX BLDG/

1412 ESE-1A 763 ITT Barton A 0 B AB BOTH ELEV 2026-0 ABPT0525 Y MAIN STEAM PRESSURE LOOP 2 145 AUX BLDG/

1412 ESE-1A 763 ITT Barton A D B AB BOTH ELEV 2026-0 ABPT0526 Y MAIN STEAM PRESSURE LOOP 2 145 AUX BLDG/

1412 ESE-1A 763 ITT Barton A D B AB BOTH ELEV 2026-0 ABPT0534 Y MAIN STEAM PRESSURE LOOP 3 145 AUX BLDG/

1412 ESE-1A 763 ITT Barton A D 8 AB BOTH ELEV 2026-0 ABPT0535 Y MAIN STEAM PRESSURE LOOP 3 145 AUX BLDG/

1412 ESE-1A 763 ITT Barton A 0 B AB BOTH ELEV 2026-0 ABPT0536 Y MAIN STEAM PRESSURE LOOP 3 145 AUX BLDG/

1412 ESE-1A 763 ITT Barton A D B AB BOTH ELEV2026-0 ABPT0544 Y MAIN STEAM PRESSURE LOOP 4 145 AUX BLDG/

1411 ESE-1A 763 ITT Barton A 0 B AB BOTH ELEV 2026-0

EQSD-11 Rev. 28 Table 1: EO Harsh Environment Equipment List 8 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es c L L SHUT A 8 B DOWN ABPT0545 Y MAIN STEAM PRESSURE LOOP 4 145 AUX BLDG/

1411 ESE-1A 763 ITT Barton A D B AB BOTH ELEV 2026-0 ABPT0546 Y MAIN STEAM PRESSURE LOOP 4 145 AUX BLDG/

1411 ESE-1A 763 ITT Barton A D B AB BOTH ELEV 2026-0 ABPV0001-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1508 E-093 NOB. 616822 Buchanan (Amerace) B D A AB BOTH 31 ELEV 2026-0 ABPV0002-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1509 E-093 NOB. 616822 Buchanan (Amerace) B D A AB BOTH 31 ELEV2026-0 ABPV0003-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1509 E-093 NOB. 616822 Buchanan (Amerace) B D A AB BOTH 31 ELEV 2026-0 ABPV0004-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1508 E-093 NOB. 616822 Buchanan (Amerace) B D A AB BOTH 31 ELEV 2026-0 ABZS0001 Y ABPV0001 LIMIT SWITCH 145 AUX BLDG/

1508 NAMCO EA180-11302/ EA180-NAMCO B D A AB BOTH 31 ELEV 2026-0 12302 ABZS0002 Y ABPV0002 LIMIT SWITCH 145 AUX BLDG/

1509 NAMCO EA180-11302/ EA180-NAMCO B D A AB BOTH 31 ELEV 2026-0 12302 ABZS0003 Y ABPV0003 LIMIT SWITCH 145 AUX BLDG/

1509 NAMCO EA180-11302/ EA180-NAMCO B 0 A AB BOTH 31 ELEV 2026-0 12302 ABZS0004 Y ABPV0004 LIMIT SWITCH 145 AUX BLDG/

1508 NAMCO EA180-11302/ EA180-NAMCO B D A AB BOTH 31 ELEV 2026-0 12302 ABZS0005 Y ABHVOOOS LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO c 0 A AB BOTH ELEV 2026-0 12302 ABZS0006 Y ABHV0006 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO C D A AB BOTH ELEV 2026-0 12302 ABZS0007A Y ABLV0007 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH ELEV 2026-0 12302 ABZS0007B Y ABLV0007 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH ELEV 2026-0 12302 ABZS0008A Y ABLV0008 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH ELEV2026-0 12302 ABZS0008B Y ABLV0008 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180*

NAMCO A D A AB BOTH ELEV2026-0 12302 ABZS0009A Y ABLV0009 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH ELEV 2026-0 12302 ABZS0009B Y ABLV0009 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH ELEV2026-0 12302 ABZS0010A Y ABLV0010 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA 180-11302/ EA 180-NAMCO A D A AB BOTH ELEV2026-0 12302 ABZS0010B Y ABLV0010 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH ELEV 2026-0 12302 ABZS0012A Y ABHV0012 LIMIT SWITCH 145 AUX BLDG/

1508 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV2026-0 12302

-**~*-...

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 9 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0

E S em COLD es c L L SHUT A B B DOWN I

ABZS0012B Y ABHV0012 LIMIT SWITCH 145 AUX BLDG/

1508 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV 2026-0 12302 ABZS0015A Y ABHV0015 LIMIT SWITCH 145 AUX BLDG/

1508 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV 2026-0 12302 ABZS0015B Y ABHV0015 LIMIT SWITCH 145 AUX BLDG/

1508 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV2026-0 12302 ABZS0018A Y ABHV0018 LIMIT SWITCH 145 AUX BLDG/

1509 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV2026-0 12302 ABZS0018B Y ABHV0018 LIMIT SWITCH 145 AUX BLDG/

1509 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV 2026-0 12302 ABZS0021A Y ABHV0021 LIMIT SWITCH 145 AUX BLDG/

1509 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV2026-0 12302 ABZS00218 Y ABHV0021 LIMIT SWITCH 145 AUX BLDG/

1509 NAMCO EA180-11302/ EA180-NAMCO A D A AB BOTH 31 ELEV2026-0 12302 ABZS0048 Y ABHV0048 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO C D A AB BOTH ELEV 2026-0 12302 ABZS0049 Y ABHV0049 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO C D A AB BOTH ELEV2026-0 12302 AEFV0039-MV1 Y LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-1 AEFV0039-MV2 Y LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-2 AEFV0039-MV3 Y LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-3 AEFV0039-MV4 Y LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-4 AEFV0039-MV5 Y LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-5 AEFV0039-MV6 Y LOOP 1 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-6 AEFV0040-MV1 Y LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-1 AEFV0040-MV2 Y LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-2

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 10 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L SHUT A B B DOWN AEFV0040-MV3 Y LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-3 AEFV0040-MV4 Y LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-4 AEFV0040-MV5 Y LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-5 AEFV0040-MV6 Y LOOP 2 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-6 AEFV0041-MV1 Y LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-1 AEFV0041-MV2 Y LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-2 AEFV0041-MV3 Y LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-3 AEFV0041-MV4 Y LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-4 AEFV0041-MV5 Y LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-5 AEFV0041-MV6 Y LOOP 3 MAIN FEEDWATER ISO 145 AUX BLDG/

1412 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-6 AEFV0042-MV1 Y LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-1 AEFV0042-MV2 Y LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-2 AEFV0042-MV3 Y LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV 2026-0 MV-3 AEFV0042-MV4 Y LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-4

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 11 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L SHUT A B 8 DOWN AEFV0042-MV5 y LOOP 4 MAIN FEEDWATER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-5 AEFV0042-MV6 Y LOOP 4 MAIN FEEDWA TER ISO 145 AUX BLDG/

1411 M-630 MV-1 CCI A D A AE BOTH VALVE CONTROL SOLENOID VALVE ELEV2026-0 MV-6 AELT0501 y SG LEVEL WIDE RANGE LOOP 1 231 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 1998-6 AELT0502 Y SG LEVEL WIDE RANGE LOOP 2 232 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 1998-6 AELT0503 Y SG LEVEL WIDE RANGE LOOP 3 232 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 1998-6 AELT0504 Y SG LEVEL WIDE RANGE LOOP 4 231 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 1998-6 AELT0517 Y SG LEVEL NARROW RANGE LOOP 1 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 2026-0 AELT0518 Y SG LEVEL NARROW RANGE LOOP 1 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AELT0519 Y SG LEVEL NARROW RANGE LOOP 1 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 9

2026-0 AELT0527 Y SG LEVEL NARROW RANGE LOOP 2 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 2026-0 AELT0528 Y SG LEVEL NARROW RANGE LOOP 2 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AELT0529 Y SG LEVEL NARROW RANGE LOOP 2 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AELT0537 Y SG LEVEL NARROW RANGE LOOP 3 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AELT0538 Y SG LEVEL NARROW RANGE LOOP 3 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AELT0539 Y SG LEVEL NARROW RANGE LOOP 3 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AELT0547 Y SG LEVEL NARROW RANGE LOOP 4 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITIBarton A D A AE BOTH 9

2026-0 AELT0548 Y SG LEVEL NARROW RANGE LOOP 4 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AELT0549 Y SG LEVEL NARROW RANGE LOOP 4 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 2026-0 AELT0551 Y SG LEVEL NARROW RANGE LOOP 1 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 9

2026-0 AELT0552 Y SG LEVEL NARROW RANGE LOOP 2 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITI Barton A D A AE BOTH 2026-0

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 12 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0

E S em COLD es C L L SHUT A B 8 DOWN AELT0553 Y SG LEVEL NARROW RANGE LOOP 3 242 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 2026-0 AELT0554 Y SG LEVEL NARROW RANGE LOOP 4 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A AE BOTH 9

2026-0 AEZS0043 Y AEFV0043 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA 180-11302/ EA180-NAMCO C D A AE BOTH ELEV 2026-0 12302 AEZS0044 Y AEFV0044 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO C D A AE BOTH ELEV 2026-0 12302 AEZS0045 Y AEFV0045 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO C D A AE BOTH ELEV 2026-0 12302 AEZS0046 Y AEFV0046 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA180-11302/ EA180-NAMCO C D A AE BOTH ELEV 2026-0 12302 BB004A Y TC REFERENCE JUNCTION BOX 251 RX BLDG/ ELEV 2000 ESE-44A WX-34794 Westinghouse A D A BB 2047-6 BB004A-E01 Y TC REFERENCE JUNCTION BOX 231 RX BLDG/ ELEV 2000 ESE-43G 4-Wire Cu Wire/Brass at Westinghouse A D A BB SPLICES - RTO 1998-6 the reference junction box BB004A-E02 N TC REFERENCE JUNCTION BOX 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A 0 A BB SPLICES -THERMOCOUPLE 1998-6 assemblies Engineering 88004B Y TC REFERENCE JUNCTION BOX 251 RX BLDG/ ELEV 2000 ESE-44A WX-34794 Westinghouse A D A BB 2047-6 BB004B-E01 Y TC REFERENCE JUNCTION BOX 231 RX BLDG/ ELEV 2000 ESE-43G 4-Wire Cu Wire/Brass at Westinghouse A D A BB SPLICES - RTO 1998-6 the reference junction box BB004B-E02 N TC REFERENCE JUNCTION BOX 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A 88 SPLICES - THERMOCOUPLE 1998-6 assemblies Engineering BBFT0017 Y RCP 1A THRM BARR CLG FLOW 241 RX BLDG/ ELEV 2000 J-301 1153DD4RA Rosemount Nuclear B 0 B BB BOTH 2026-0 BBFT0018 Y RCP 1 B THRM BARR CLG FLOW 232 RX BLDG/ ELEV 2000 J-301 1153DD4RA Rosemount Nuclear B D B BB BOTH 1998-6 BBFT0019 Y RCP 1 C THRM BARR CLG FLOW 242 RX BLDG/ ELEV 2000 J-301 1153DD4RA Rosemount Nuclear B D B BB BOTH 2026-0 BBFT0020 Y RCP 1 0 THRM BARR CLG FLOW 241 RX BLDG/ ELEV 2000 J-301 1153DD4RA Rosemount Nuclear B 0 B BB BOTH 2026-0 BBHV0013 N RCP THERMAL BARRIER COOLER 2026' CTMT BLDG 2000 LIMITORQUE SB-00 LIMITORQUE B D B BB BOTH ISOLATION VALVE BBHV0014 N RCP THERMAL BARRIER COOLER 2000' CTMT BLDG.

2000 LIMITORQUE SB-00 LIMITORQUE B D B BB BOTH ISOLATION VALVE BBHV0015 N RCP THERMAL BARRIER COOLER 2026' CTMT BLDG 2000 LIMITORQUE SB-00 LIMITORQUE B 0 B 88 BOTH ISOLATION VALVE 8BHV0016 N RCP THERMAL BARRIER COOLER 232 RX BLDG/ ELEV 2000 LIMITORQUE SB-00 LIMITORQUE B D B BB BOTH ISOLATION VALVE 1998-6 c-

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 13of51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0

E S em COLD es c L L SHUT A B B DOWN BBHVSOOOA N PRESSURIZER PORV ISOLATION 261 RX BLDG/ ELEV 2601 LIMITORQUE SB-00 LIMIT OR QUE A D A BB BOTH VALVE 2068-8 BBHV8000B N PRESSURIZER PORV ISOLATION 261 RX BLDG/ ELEV 2601 LIMITORQUE SB-00 LIMITORQUE A D A BB BOTH VALVE 2068-8 BBHV8001A y REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-10A 79AB-001BB Target Rock Corp.

A D A BB COLD 20 VALVE 2047-6 BBHV8001A-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-8 N11085 Con ax A D A BB COLD 20 VALVE CONNECTOR 2047-6 BBHV8001A-E02 N VALVE TERMINAL BOX 252 RX BLDG/ ELEV 2000 E-028 1600 NUC Marathon Special A D A BB 20 2047-6 Products BBHV8001B Y REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-10A 79AB-001BB Target Rock Corp.

A D A BB COLD 20 VALVE 2047-6 BBHV8001 B-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-8 N11085 Con ax A D A BB COLD 20 VALVE CONNECTOR 2047-6 BBHV8001 B-E02 N VALVE TERMINAL BOX 252 RX BLDG/ ELEV 2000 E-028 1600 NUC Marathon Special A D A BB 20 2047-6 Products BBHV8002A Y REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-10A 79AB-001BB Target Rock Corp.

A D A BB COLD 20 VALVE 2047-6 BBHV8002A-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-8 N11085 Conax A D A BB COLD 20 VALVE CONNECTOR 2047-6 BBHV8002A-E02 N VALVE TERMINAL BOX 252 RX BLDG/ ELEV 2000 E-028 1600 NUC Marathon Special A D A BB 20 2047-6 Products BBHV8002B Y REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-10A 79AB-001BB Target Rock Corp.

A D A BB COLD 20 VALVE 2047-6 BBHV8002B-E01 N REACTOR VESSEL HEAD VENT 252 RX BLDG/ ELEV 2000 HE-8 N11085 Con ax A D A BB COLD 20 VALVE CONNECTOR 2047-6 BBHV8002B-E02 N VALVE TERMINAL BOX 252 RX BLDG/ ELEV 2000 E-028 1600 NUC Marathon Special A D A BB 20 2047-6 Products BBHV8010A-E01 N VALVE TERMINAL BOX 261 RX BLDG 2000 E-028 1600 NUC Marathon Special A D A BB BOTH Products BBHV801 OB-E01 N VALVE TERMINAL BOX 261 RX BLDG 2000 E-028 1600 NUC Marathon Special A D A BB BOTH Products BBHV801 OC-E01 N VALVE TERMINAL BOX 261 RX BLDG 2000 E-028 1600 NUC Marathon Special A D A BB BOTH Products BBHV8026-E01 N VALVE TERMINAL BOX 231 RX BLDG/ ELEV 2000 E-0358 601-JJ, 602-JJ, 604-JJ Kulka A D A BB 1998-6 BBHV8027-E01 N VALVE TERMINAL BOX 133 AUX BLDG/

1322 E-035B 601-JJ, 602-JJ, 604-JJ Kulka A D D BB ELEV2000-0 BBHV8351A N RCP SEAL INJECTION CONTAINMENT 133 AUX BLDG/

1322 LIMITORQUE SMB-00 LIMITORQUE A D D BB BOTH ISOLATION VALVE ELEV 2000-0 BBHV8351B N RCP SEAL INJECTION CONTAINMENT 133 AUX BLDG/

1322 LIMITORQUE SMB-00 LIMITORQUE A D D BB BOTH ISOLATION VALVE ELEV2000-0

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 14 of 51 Component M Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es c L L SHUT A B 8 DOWN BBHV8351C N RCP SEAL INJECTION CONTAINMENT 133 AUX BLDG/

1322 LIMITORQUE SMB-00 LIMITORQUE A D D BB BOTH ISOLATION VALVE ELEV 2000-0 BBHV8351D N RCP SEAL INJECTION CONTAINMENT 133 AUX BLDG/

1322 LIMITORQUE SMB-00 LIMITORQUE A D D BB BOTH ISOLATION VALVE ELEV 2000-0 BBHY8026 N CONTAINMENT ISOL VALVE 231 RX BLDG/ ELEV 2000 HE-2 NPK831654E ASCO A D A BB NITROGEN SUPPLY TO PRT 1998-6 8BHY8026-E01 N CONT ISOL VL V NITROGEN SUPPLY 231 RX BLDG/ ELEV 2000 HE-8 N11007 Con ax A D A BB TO PRT CONNECTOR 1998-6 BBHY8027 N CONTAINMENT ISOL VALVE 133 AUX BLDG/

1322 HE-5 NPK831654E ASCO A D D BB NITROGEN SUPPLY TO PRT ELEV 2000-0 BBLIS1311 N RVLIS HYDRAULIC ISOLATOR 134 AUX BLDG/

1323 ESE-49A 581-4 ITT Barton A D D BB 26 ELEV 2000-0 BBLIS1312 N RVLIS HYDRAULIC ISOLATOR 134 AUX BLDG/

1323 ESE-49A 581-4 ITT Barton A D D BB 26 ELEV 2000-0 BBLIS1321 N RVLIS HYDRAULIC ISOLATOR 133 AUX BLDG/

1322 ESE-49A 581-4 ITT Barton A D D BB 26 ELEV 2000-0 BBLIS1322 N RVLIS HYDRAULIC ISOLATOR 133 AUX BLDG/

1322 ESE-49A 581-4 ITT Barton A D D BB 26 ELEV 2000-0 BBLT0459 Y PRESSURIZER LEVEL TRANSMITTER 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A 88 BOTH 2026-0 BBLT0460 Y PRESSURIZER LEVEL TRANSMITTER 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A BB BOTH 2026-0 BBLT0461 Y PRESSURIZER LEVEL TRANSMITTER 241 RX BLDG/ ELEV 2201 ESE-3A 764 ITT Barton A D A BB BOTH 2026-0 BBLT1311 N REACTOR VESSEL LEVEL 134 AUX BLDG/

1320 ESE-4A 752 ITT Barton A C D BB 26 TRANSMITTER NARROW RANGE ELEV2000-0 30 BBLT1312 N REACTOR VESSEL LEVEL 134 AUX BLDG/

1320 ESE-4A 752 ITT Barton A C D BB 26 TRANSMITTER WIDE RANGE ELEV2000-0 30 BBLT1321 N REACTOR VESSEL LEVEL 121 AUX BLDG/

1202 ESE-4A 752 ITT Barton A C D BB 26 TRANSMITTER NARROW RANGE ELEV 1988-0 BBLT1322 N REACTOR VESSEL LEVEL 123 AUX BLDG/

1202 ESE-4A 752 ITT Barton A C D BB 26 TRANSMITTER WIDE RANGE ELEV 1988-0 BBPCV0455A Y PRESSURIZER POWER OPERA TED 261 RX BLDG/ ELEV 2601 HE-9 3750014 Westinghouse/

A D A BB BOTH RELIEF VALVE 2068-8 Garrett BBPCV0455A-E01 N PRESSURIZER POWER OPERA TED 241 RX BLDG/ ELEV 2601 HE-8 N11007 Con ax A D A BB BOTH RELIEF VLV CONNECTOR 2026-0 BBPCV0455A-E02 N VALVE TERMINAL BOX 261 RX BLDG/ ELEV 2601 E-028 1600-NUC Marathon Special A D A BB BOTH 2068-8 Products BBPCV0456A Y PRESSURIZER POWER OPERATED 261 RX BLDG/ ELEV 2601 HE-9 3750014 Westinghouse!

A D A 88 BOTH RELIEF VALVE 2068-8 Garrett BBPCV0456A-EO 1 N PRESSURIZER POWER OPERATED 261 RX BLDG! ELEV 2601 HE-8 N11007 Con ax A D A BB BOTH RELIEF VLV CONNECTOR 2068-8

EQS0-11 Rev. 28 Table 1: EO Harsh Environment Equipment List 15 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not I Number c

Room 0 E s em COLD es c L L SHUT A B B DOWN BBPCV0456A-E02 N VALVE TERMINAL BOX 261 RX BLDG/ ELEV 2601 E-028 1600-NUC Marathon Special A D A BB BOTH 2068-8 Products BBPT0403 y REACTOR COOLANT SYSTEM 123 AUX BLDG/

1202 ESE-1A 763 ITT Barton A A D BB BOTH PRESSURE WIDE RANGE ELEV 1988-0 BBPT0405 Y REACTOR COOLANT SYSTEM 134 AUX BLDG/

1320 ESE-1B 76PHSS Veritrak A A D BB BOTH 30 PRESSURE WIDE RANGE ELEV 2000-0 BBPT0406 y REACTOR COOLANT SYSTEM 133 AUX BLDG/

1202 ESE-1A 763 ITT Barton A A D BB BOTH PRESSURE WIDE RANGE ELEV 2000-0 BBPT0455 Y PRESSURIZER PRESSURE 241 RX BLDG/ ELEV 2201 J-301 1154SH9RA Rosemount Nuclear A D A BB BOTH TRANSMITTER 2026-0 BBPT0456 Y PRESSURIZER PRESSURE 241 RX BLDG/ ELEV 2201 J-301 1154SH9RA Rosemount Nuclear A D A BB BOTH TRANSMITTER 2026-0 BBPT0457 Y PRESSURIZER PRESSURE 251 RX BLDG/ ELEV 2201 J-301 1154SH9RA Rosemount Nuclear A D A BB BOTH TRANSMITIER 2047-6 BBPT0458 Y PRESSURIZER PRESSURE 251 RX BLDG/ ELEV 2201 J-301 1154SH9RA Rosemount Nuclear A D A BB BOTH TRANSMITIER 2047-6 BBPV8702A N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ ELEV 2000 LIMITORQUE SMB-2 LIMITORQUE C D A BB BOTH VALVE 1998-6 BBPV8702B N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ ELEV 2000 LIMITORQUE SMB-2 LIMITORQUE c D A BB BOTH VALVE 1998-6 BBT/C0001 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0001 -E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0002 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0002-E01 N THERMOCOUPLE CONNECTOR!

231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0003 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0003-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0004 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT /C0004-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0005 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0005-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0006 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

~ - -

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 16 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es c L L SHUT A B B DOWN BBT/C0006-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0007 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0007 -E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0008 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0008-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0009 N RV CORE SUBCOOLING MONITOR 241 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 2026-0 Inc.

BBT/C0009-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0010 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C001 O-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0012 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0012-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0013 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0013-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0014 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998*6 Inc.

BBT/C0014-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0015 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0015-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0017 N RV CORE SUBCOOUNG MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0017 -E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0018 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0018-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering

___ [ _ ____

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 17 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es c L L SHUT A B 8 DOWN BBT/C0019 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0019-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0020 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0020-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0021 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0021-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0022 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0022-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0023 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0023-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0024 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0024-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0025 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0025-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0026 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE*43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0026-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0027 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0027 -E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0028 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0028-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0029 N RV CORE SUBCOOUNG MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

EQSD-11 Rev. 28 Table 1: EO Harsh Environment Equipment List 18 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E s em COLD es c L L SHUT A B B DOWN BBT/C0029-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0030 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A 88 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0030-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0031 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0031-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0032 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0032-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral Insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0033 N RV CORE SUBCOOUNG MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0033-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A 0 A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0034 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0034-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A 0 A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0036 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0036-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A 0 A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0037 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0037-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A 0 A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0038 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0038-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0039 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A 0 A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0039-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A 0 A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0040 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A 0 A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0040-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A 0 A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering

-- ~

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 19 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E s em COLD es c L L SHUT A B 8 DOWN BBT/C0041 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0041-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0042 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0042-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0043 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0043-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 i CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0044 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0044-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0045 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0045-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0046 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0046-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0047 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0047-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0048 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0048-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0049 N RV CORE SUBCOOLING MONITOR 231 RX BLDG/ ELEV 2000 ESE-43A TypeK Westinghouse/ CKB A D A BB 26 THERMOCOUPLES 1998-6 Inc.

BBT/C0049-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBT/C0050 N IN CORE THERMOCOUPLES 231 RX BLDG/ ELEV 2000 ESE-43A Type K Westinghouse/ CKB A D A BB 26 1998-6 Inc.

BBT/C0050-E01 N THERMOCOUPLE 231 RX BLDG/ ELEV 2000 J-565 Mineral insulated cable Combustion A D A BB 26 CONNECTOR/CABLE ASSEMBLIES 1998-6 assemblies Engineering BBTE0410A1 Y RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB I

(INSTALLED SPARE) 1998-6 Inc.

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 20 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not I Number c

Room 0 E s em COLD es c L L SHUT I

A B B DOWN BBTE0410A2 y RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0410A3 y RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A B8 (INSTALLED SPARE) 1998-6 Inc.

BBTE0410B y RCS COLD LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A B8 (INSTALLED SPARE) 1998-6 Inc.

BBTE0411A1 y RCS HOT LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A BB BOTH LOOP1 1998-6 Inc.

BBTE0411A2 Y RCS HOT LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A BB BOTH LOOP 1 1998-6 Inc.

BBTE0411A3 Y RCS HOT LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP 1 1998-6 Inc.

BBTE0411B Y RCS COLD LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A BB BOTH LOOP 1 1998-6 Inc.

BBTE0413A N RCS HOT LEG TEMPERATURE 231 RX BLDG/ ELEV 2201 ESE-6 21205 RDF Corp.

A D A BB BOTH ELEMENT (WR) LOOP 1 1998-6 BBTE0413A-E01 N RCS HOT LEG RTD CONNECTOR (WR) 231 RX BLDG/ ELEV 2201 HE-8 N11007 Con ax A D A BB BOTH LOOP 1 1998-6 BBTE0413B N RCS COLD LEG TEMP ELEMENT (WR) 231 RX BLDG/ ELEV 2201 ESE-6 21205 RDF Corp.

A D A BB BOTH LOOP 1 1998-6 BBTE0413B-E01 N RCS COLD LEG RTD CONNECTOR 231 RX BLDG/ ELEV 2201 HE-8 N11007 Con ax A D A BB BOTH (WR) LOOP 1 1998-6 BBTE0420A1 Y RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0420A2 Y RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0420A3 Y RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A 88 (INSTALLED SPARE) 1998-6 Inc.

BBTE0420B Y RCS COLD LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0421A1 Y RCS HOT LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP2 1998-6 Inc.

BBTE0421A2 Y RCS HOT LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP2 1998-6 Inc.

BBTE0421A3 Y RCS HOT LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A 8B BOTH LOOP2 1998-6 Inc.

BBTE0421B Y RCS COLD LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP2 1998-6 Inc.

BBTE0423A N RCS HOT LEG TEMP ELEMENT {WR) 232 RX BLDG/ ELEV 2201 ESE-6 21205 RDF Corp.

A D A BB BOTH LOOP2 1998-6 BBTE0423A-E01 N RCS HOT LEG RTD CONNECTOR (WR) 232 RX BLDG/ ELEV 2201 HE-8 N11007 Conax A D A BB BOTH LOOP2 1998-6

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 21 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not I Number c

Room 0

E S em COLD es C L L SHUT A 8 8 DOWN BBTE0423B N RCS COLD LEG TEMP ELEMENT (WR) 232 RX BLDG/ ELEV 2201 ESE-6 21205 RDFCorp.

A D A BB BOTH LOOP2 1998-6 BBTE0423B-E01 N RCS COLD LEG RTD CONNECTOR 232 RX BLDG/ ELEV 2201 HE-8 N11007 Con ax A D A BB BOTH (WR)LOOP2 1998-6 BBTE0430A1 Y RCS HOT LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB LOOP3 1998-6 Inc.

BBTE0430A2 y RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0430A3 Y RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0430B Y RCS COLD LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E*2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0431A1 Y RCS HOT LEG RTD TEMP ELE 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH (INSTALLED SPARE) 1998-6 Inc.

BBTE0431A2 y RCS HOT LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP3 1998-6 Inc.

BBTE0431A3 Y RCS HOT LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP3 1998-6 Inc.

BBTE0431B Y RCS COLD LEG RTD TEMP ELEMENT 232 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP3 1998-6 Inc.

BBTE0433A N RCS HOT LEG TEMPERATURE 232 RX BLDG/ ELEV 2201 ESE-6 21205 RDF Corp.

A D A BB BOTH ELEMENT (WR) LOOP 3 1998-6 BBTE0433A-E01 N RCS HOT LEG RTD CONNECTOR {WR) 232 RX BLDG/ ELEV 2201 HE-8 N11007 Conax A D A BB BOTH LOOP3 1998-6 BBTE0433B N RCS COLD LEG TEMPERATURE 232 RX BLDG/ ELEV 2201 ESE-6 21205 RDF Corp.

A D A BB BOTH ELEMENT (WR) LOOP 3 1998-6 BBTE0433B-E01 N RCS COLD LEG RTD CONNECTOR 232 RX BLDG/ ELEV 2201 HE-8 N11007 Con ax A D A BB BOTH (WR) LOOP 3 1998-6 BBTE0440A1 Y RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0440A2 Y RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0440A3 y RCS HOT LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0440B Y RCS COLD LEG RTD TEMP ELE 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB (INSTALLED SPARE) 1998-6 Inc.

BBTE0441A1 Y RCS HOT LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP4 1998-6 Inc.

BBTE0441A2 y RCS HOT LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH LOOP4 1998-6 Inc.

BBTE0441A3 Y RCS HOT LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., C D A BB BOTH

,I_()~OP 4 1998-6 Inc.

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 22 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es c L L SHUT A 8 8 DOWN BBTE0441B Y RCS COLD LEG RTD TEMP ELEMENT 231 RX BLDG/ ELEV 2201 J-564 N9004E-2A-SP Weed Instrument Co., c D A BB BOTH LOOP4 1998-6 Inc.

BBTE0443A N RCS HOT LEG TEMPERATURE 231 RX BLDG/ ELEV 2201 ESE-6 21205 RDF Corp.

A D A BB BOTH ELEMENT (WR} LOOP 4 1998-6 BBTE0443A-E01 N RCS HOT LEG RTD CONNECTOR (WR) 231 RX BLDG/ ELEV 2201 HE-8 N11007 Con ax A D A BB BOTH LOOP4 1998-6 88TE0443B N RCS COLD LEG TEMPERATURE 231 RX BLDG/ ELEV 2201 ESE-6 21205 RDF Corp.

A D A BB BOTH ELEMENT (WR) LOOP 4 1998-6 BBTE04438-E01 N RCS COLD LEG RTD CONNECTOR 231 RX BLDG/ ELEV 2201 HE-8 N11007 Con ax A D A BB BOTH (WR) LOOP4 1998-6 BBTE1313 N RVLIS HEAD IMPULSE LINE TEMP 242 RX BLDG! ELEV 2000 ESE-42A S8810 MINCO!

A D A BB 26 ELEMENT 2026-0 Westinghouse BBTE1314 N RVLIS HEAD IMPULSE liNE TEMP 242 RX BLDG! ELEV 2000 ESE-42A S8810 MINCO/

A D A BB 26 ELEMENT 2026-0 Westinghouse BBTE1317 N RVLIS SEAL IMPULSE LINE TEMP 241 RX BLDG! ELEV 2000 ESE-42A S8810 MINCO/

A D A BB 26 ELEMENT 2026-0 Westinghouse BBTE1318 N RVLIS SEAL IMPULSE LINE TEMP 241 RX BLDG/ ELEV 2000 ESE-42A S8810 MINCO!

A D A BB 26 ELEMENT 2026-0 Westinghouse 88TE1323 N RVLIS HEAD IMPULSE LINE TEMP 241 RX BLDG! ELEV 2000 ESE-42A S8810 MINCO/

A D A BB 26 ELEMENT 2026-0 Westinghouse BBTE1324 N RVLIS HEAD IMPULSE liNE TEMP 241 RX BLDG/ ELEV 2000 ESE-42A 88810 MINCO/

A D A 88 26 ELEMENT 2026-0 Westinghouse BBTE1327 N RVLIS SEAL IMPULSE LINE TEMP 242 RX BLDG! ELEV 2000 ESE-42A S8810 MINCO/

A D A 88 26 ELEMENT 2026-0 Westinghouse BBTE1328 N RVUS SEAL IMPULSE LINE TEMP 242 RX BLDG/ ELEV 2000 ESE-42A S8810 MINCO!

A D A BB 26 ELEMENT 2026-0 Westinghouse BBTE1329 N RVLIS HEAD IMPULSE LINE TEMP 241 RX BLDG/ ELEV 2000 ESE-42A S8810 MINCO/

A D A BB 26 ELEMENT 2026-0 Westinghouse BBZS0455A Y PRESSURIZER PORV LIMIT SWITCH 261 RX BLDG! ELEV 2601 HE-9 3760060 Westinghouse/

A D A BB BOTH 22 2068*8 Garrett BBZS0455A-E01 N PRESSURIZER PORV LIMIT SWITCH 261 RX BLDG! ELEV 2601 HE-8 N11007 Con ax A 0 A BB BOTH 22 CONNECTOR 2068-8 BBZS0456A Y PRESSURIZER PORV LIMIT SWITCH 261 RX BLDG/ ELEV 2601 HE-9 3760060 Westinghouse/

A D A BB BOTH 22 2068-8 Garrett BBZS0456A-E01 N PRESSURIZER PORV LIMIT SWITCH 261 RX BLDG/ ELEV 2601 HE-8 N11007 Con ax A D A BB BOTH 22 CONNECTOR 2068-8 B8ZS8010A Y PRESSURIZER SAFETY RELIEF 261 RX BLDG/ ELEV 2602 HE-7 65322 Westinghouse/

A D A 88 BOTH 22 VALVE LIMIT SWITCH 2068-8 Garrett BBZS801 OA-E01 N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ ELEV 2602 HE-8 N11007 Con ax A 0 A 88 BOTH 22 VALVE LS CONNECTOR 2068-8 BBZS8010B Y PRESSURIZER SAFETY RELIEF 261 RX BLDG/ ELEV 2602 HE-7 65322 Westinghouse/

A D A BB BOTH 22 VALVE LIMIT SWITCH 2068-8 Garrett

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 23 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQ Spec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E s em COLD es c L L SHUT A B B DOWN BBZS801 OB-E01 N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ ELEV 2602 HE-8 N11007 Con ax A D A BB BOTH 22 VALVE LS CONNECTOR 2068-8 BBZS8010C Y PRESSURIZER SAFETY RELIEF 261 RX BLDG/ ELEV 2602 HE-7 65322 Westinghouse/

A D A BB BOTH 22 VALVE LIMIT SWITCH 2068-8 Garrett BBZS801 OC-E01 N PRESSURIZER SAFETY RELIEF 261 RX BLDG/ ELEV 2602 HE-8 N11007 Conax A D A BB BOTH 22 VALVE LS CONNECTOR 2068-8 BBZS8026 Y CONTMN ISOL VLV NIT SUPPLY TO 231 RX BLDG/ ELEV 2000 NAMCO EA180 NAMCO A D A BB PRT LIMIT SWITCH 1998-6 BBZS8026-E01 N CONT !SOL VL V NIT SUPPLY TO PRT 231 RX BLDG/ ELEV 2000 HE-8 N11007 Conax A D A 88 LS CONNECTOR 1998-6 BBZS8027 Y CONTMN ISOL VLV NIT SUPPLY TO 231 RX BLDG/ ELEV 1322 NAMCO EA 180-35303 NAMCO A D D BB PRT LIMIT SWITCH 1998-6 BBZS8702AA Y RHR PUMP SUCTION ISOLATION 231 RX BLDG/ ELEV 2000 NAMCO EA180-12303 NAMCO C D A BB BOTH VALVE LIMIT SWITCH 1998-6 BBZS8702AA-E01 N VALVE TERMINAL BOX (BBZS8702AB) 231 RX BLDG/ ELEV 2000 E-028 1600-NUC Marathon Special A D A BB BOTH 1998-6 Products BBZS8702AA-E02 N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ ELEV 2000 HE-8 N11007 Conax C D A BB BOTH VALVE LS CONNECTOR 1998-6 BBZS8702AB Y RHR PUMP SUCTION ISOLATION 231 RX BLDG/ ELEV 2000 NAMCO EA 180-12303 NAMCO C D A BB BOTH VALVE LIMIT SWITCH 1998-6 BBZS8702AB-E01 N RHR PUMP SUCTION ISOLATION 231 RX BLDG/ ELEV 2000 HE-8 N11007 Conax C D A BB BOTH VALVE LS CONNECTOR 1998-6 BGFT0215A Y RCP SEAL INJECTION FLOW 123 AUX BLDG/

1202 J-301 1153HB5RCN0012 Rosemount Nuclear A C D BG BOTH TRANSMITTER ELEV 1988-0 BGFT0215A-E01 N RCP SEAL INJECTION FLOW 123 AUX BLDG/

1202 ESE-4A 752 ITT Barton A C D BG BOTH TRANSMITTER ELEV 1988-0 BGFT0215B N RCP SEAL INJECTION FLOW 123 AUX BLDG/

1202 ESE-4A 752 ITT Barton A C D BG BOTH TRANSMITTER ELEV 1988-0 BGFT0215B-E01 N RCP SEAL INJECTION FLOW 123 AUX BLDG/

1202 ESE-40 1153HB5RC Rosemount Nuclear A C D BG BOTH TRANSMITTER ELEV 1988-0 BGHV8100 N SEAL WATER RETURN 133 AUX BLDG/

1322 LIMITORQUE SMB-00 LIMITORQUE A D D BG CONTAINMENT ISOLATION VALVE ELEV 2000-0 BGHV8105 N CHARGING LINE CONTAINMENT 134 AUX BLDG/

1323 LIMITORQUE SB-00 LIMITORQUE A D D BG BOTH ISOLATION VALVE ELEV 2000-0 BGHV8106 N CHARGING LINE ISOLATION VALVE 134 AUX BLDG/

1323 LIMITORQUE SB-00 LIMITORQUE A D D BG BOTH ELEV 2000-0 BGHV8110 N CCP A MINIFLOW ISOLATION VALVE 112 AUX BLDG/

1114 LIMITORQUE SMB-00 LIMITORQUE A D D BG BOTH 29 ELEV 1974-0 BGHV8111 N CCP 8 MINIFLOW ISOLATION VALVE 111 AUX BLDG/

1107 LIMITORQUE SMB-00 LIMITORQUE A D D BG BOTH 28 ELEV 1974-0 BGHV8112 N SEAL WATER RETURN 231 RX BLDG/ ELEV 2000 LIMITORQUE SMB-00 LIMITORQUE A D A BG CONTAINMENT ISOL VALVE 1998-6

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 24 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L SHUT A B 8 DOWN BGHV8152-E01 N VALVE TERMINAL BOX 133 AUX BLDG/

1322 E-093 NQB. 616822 Buchanan (Amerace) A D D BG ELEV 2000-0 BGHV8153A y EXCESS LETDOWN/RCS ISOLATION 231 RX BLDG/ ELEV 2000 HE-10A 79AB-001-2 Target Rock Corp.

C D B BG BOTH VALVE 1998-6 BGHV8153A-E01 N EXCESS LETDOWN/RCS ISOLATION 231 RX BLDG/ ELEV 2000 HE-8 N11007 Con ax C D B BG BOTH VALVE CONNECTOR 1998-6 BGHV8153B Y EXCESS LETDOWN/RCS ISOLATION 231 RX BLDG/ ELEV 2000 HE-10A 79AB-001-2 Target Rock Corp.

C D B BG BOTH VALVE 1998-6 BGHV8153B-E01 N EXCESS LETDOWN/RCS ISOLATION 231 RX BLDG/ ELEV 2000 HE-8 N11007 Con ax C D B BG BOTH VALVE CONNECTOR 1998-6 BGHV8154A Y EXCESS LETDOWN/RCS ISOLATION 231 RX BLDG/ ELEV 2000 HE-10A 79AB-001-2 Target Rock Corp.

B D B BG BOTH VALVE 1998-6 BGHV8154A-E01 N EXCESS LETDOWN/RCS ISOLATION 231 RX BLDG/ ELEV 2000 HE-8 N11007 Con ax B D B BG BOTH VALVE CONNECTOR 1998-6 BGHV8154B Y EXCESS LETDOWN/RCS ISOLATION 231 CTMT BLDG/

2000 HE-10A 79AB-001-2 Target Rock Corp.

B D B BG BOTH VALVE ELEV2006 BGHV8154B-E01 N EXCESS LETDOWN/RCS ISOLATION 231 RX BLDG/ ELEV 2000 HE-8 N11007 Con ax B D B BG BOTH VALVE CONNECTOR 1998-6 BGHV8160-E01 N VALVE TERMINAL BOX 231 RX BLDG/ ELEV 2000 E-0358 601-JJ, 602-JJ, 604-JJ Kulka A D A BG 1998-6 BGHY8152 Y LETDOWN CONTAINMENT ISOLATION 133 AUX BLDG/

1322 HE-5 NPK831654E ASCO A D D BG VALVE (BGHV8152)

ELEV2000-0 BGHY8160 Y LETDOWN CONTAINMENT ISOLATION 231 RX BLDG/ ELEV 2000 HE-2 NPK831654E ASCO A D A BG VALVE 1998-6 BGHY8160-E01 N LETDOWN CONTAINMENT ISOLATION 231 RX BLDG/ ELEV 2000 HE-8 N11007 Con ax A D A BG VALVE CONNECTOR 1998-6 BGLCV0112B N VCT ISOLATION VALVE FROM 132 AUX BLDG/

1318 LIMITORQUE SB-00 LIMITORQUE A C D BG BOTH CHARGING PUMP SUCTION ELEV2000-0 BGLCV0112C N VCT ISOLATION VALVE FROM 132 AUX BLDG/

1318 LIMITORQUE SB-00 LIMITORQUE A C D BG BOTH CHARGING PUMP SUCTION ELEV 2000-0 BGZS8152 Y LETDOWN CONTAINMENT lSOL VLV 133 AUX BLDG/

1322 NAMCO EA180-11302/ EA180-NAMCO A D D BG LMTSWITCH ELEV 2000-0 12302 BGZS8160 Y LETDOWN CONTAINMENT ISOL VLV 231 RX BLDG/ ELEV 2000 NAMCO EA180 NAMCO A D A BG LIMIT SWITCH 1998-6 BGZS8160-E01 N LETDOWN CONTAINMENT ISOL VLV 231 RX BLDG/ ELEV 2000 HE-8 N11007 Con ax A D A BG LS CONNECTOR 1998-6 BLHV8047-E01 N VALVE TERMINAL BOX 133 AUX BLDG/

1322 E-093 NQB. 616822 Buchanan (Amerace) A D D BL ELEV2000-0 BLHY8047 N CONTAINMENT ISOLATION VALVE 133 AUX BLDG/

1322 HE-5 NPK831654E ASCO A D D BL ELEV2000-0 BLZS8047 Y CONTAINMENT ISOLATION VALVE 133 AUX BLDG/

1322 NAMCO EA180-14303/ EA180-NAMCO A D D BL LIMIT SWITCH ELEV2000-0 15303

EQSD-11 Rev. 28 Table 1: EQ Harsh Environment Equipment List 25 of 51 Component M

Equipment Qualification Description Installed Elevation EQ EQSpec Model#

Manufacturer L H M Syst HOT/ Not Number c

Room 0 E S em COLD es C L L SHUT A B B DOWN BMHV0001-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1411 E-093 NQB. 616822 Buchanan (Amerace) A D A BM HOT ELEV2026-0 BMHV0002-E01 N VALVE TERMINAL BOX (AEFV0044) 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan (Amerace} A D A BM HOT ELEV 2026-0 BMHV0003-E01 N VALVE TERMINAL BOX 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan (Amerace} A D A BM HOT ELEV2026-0 BMHV0004-E01 N VALVE TERMINAL BOX (AEFV0046}

145 AUX BLDG/

1411 E-093 NQB. 616822 Buchanan (Amerace} A D A BM HOT ELEV 2026-0 BMHY0001A Y BMHV0001 SOLENOID VALVE 145 AUX BLDG/

1411 J-601A NP8321A6E ASCO A D C BM HOT ELEV 2026-0 BMHY0001B Y BMHV0001 SOLENOID VALVE 145 AUX BLDG/

1411 J-601A NP8321A6E ASCO A D C BM HOT ELEV 2026-0 BMHY0001 B-E01 N VALVE TERMINAL BOX (AEFV0043, 145 AUX BLDG/

1411 E-093 NOB. 616822 Buchanan (Amerace} A D A BM BOTH I

BMZS00018)

ELEV 2026-0 BMHY0002A Y BMHV0002 SOLENOID VALVE 145 AUX BLDG/

1412 J-601A NP8321A6E ASCO A D C BM HOT i

ELEV2026-0 BMHY0002B y BMHV0002 SOLENOID VALVE 145 AUX BLDG/

1412 J-601A NP8321A6E ASCO A D C BM HOT ELEV 2026-0 i

BMHY0002B-E01 N VALVE TERMINAL BOX (BMZS0002B) 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan (Amerace) A D A BM HOT ELEV 2026-0 BMHY0003A Y BMHV0003 SOLENOID VALVE 145 AUX BLDG/

1412 J-601A NP8321A6E ASCO A D C BM HOT ELEV 2026-0 BMHY0003B Y BMHV0003 SOLENOID VALVE 145 AUX BLDG/

1412 J-601A NP8321A6E ASCO A D C BM HOT ELEV 2026-0 BMHY0003B-E01 N VALVE TERMINAL BOX {AEFV0045, 145 AUX BLDG/

1412 E-093 NQB. 616822 Buchanan (Amerace) A 0 A BM BOTH BMZS0003B)

ELEV 2026-0 BMHY0004A y BMHV0004 SOLENOID VALVE 145 AUX BLDG/

1411 J-601A NP8321A6E ASCO A D C BM HOT ELEV 2026-0 BMHY0004B y BMHV0004 SOLENOID VALVE 145 AUX BLDG/

1411 J-601A NP8321A6E ASCO A D C BM HOT ELEV2026-0 BMHY0004B-E01 N VALVE TERMINAL BOX (BMZS0004B) 145 AUX BLDG/

1411 E-093 NQB. 616822 Buchanan (Amerace) A D A BM HOT ELEV 2026-0 BMZS0001A y BMHV0001 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA180-11302/ EA180-NAMCO A D A BM HOT ELEV2026-0 12302 BMZS0001B y BMHV0001 LIMIT SWITCH 145 AUX BLDG/

1411 NAMCO EA180-11302/ EA180-NAMCO A D A BM HOT ELEV2026-0 12302 BMZS0002A y BMHV0002 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO A D A BM HOT ELEV2026-0 12302 BMZS0002B y BMHV0002 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO A D A BM HOT ELEV 2026-0 12302 I

BMZS0003A y BMHV0003 LIMIT SWITCH 145 AUX BLDG/

1412 NAMCO EA180-11302/ EA180-NAMCO A D A BM HOT I

ELEV 2026-0 12302

-