{{#Wiki_filter: | {{#Wiki_filter:ROCHESTER GASANDELECTRICCORPORATION 89EASTAVENUESROCHESTER'Y 14649NUCLEARREGULATORY COMMISSION INSERVICE INSPECTION REPORTFORTHETHIRDINTERVAL(1990-1999)SECONDPERIODiTHIRDOUTAGE(1995)ATREGINNANUCLEARPOWERPLANTREVISION0JULY24i19959'508080402 950802PDRADOCK050002449PDR REGINNANUCLEARPOWERPLANTNUCLEARREGULATORY COMMISSION INSERVICE INSPECTION REPORTTHIRDINTERVAL(1990-1999)SECONDPERIODSTHIRDOUTAGE(1995)OWNERSDATASHEETDate:24July,1995Owner:Rochester GasandElectricCorporation 89EastAvenueRochester, NewYork14649IPlantLocationandUnitNo.:R.E.GinnaNuclearPowerPlantUnitOne1503LakeRoadOntario,NewYork14519Commercial 0eratinDate:July1970AlicableCode:ASMESectionXI,1986Edition,NoAddenda 0 | ||
R. | R.EDGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)TABLEOFCONTENTSIntroduction andSynopsisSummaryofWorkAccomplished Class1Components Class2Components Class3Components HighEnergyComponents DesignBreakWeldExaminations Consequential BreakWeldExaminations Component SupportExaminations SteamGenerators SystemPressureTestingHydrostatic TestingLeakageTestingSectionXI,ServiceInducedRejectable Components-ExpandedExaminations SnubbersVisualExaminations Functional TestingSeismicSupportProgramErosion/Corrosion (Minwall) | ||
ProgramAttachment IISIProgramExamination SummaryAttachment IIRepair,Replacement | |||
&Modification ProgramSummaryAttachment IIIErosion/Corrosion (Minwall) | |||
ProgramSummary1~ | |||
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)ZNTRODUCTION ANDSYNOPSISInservice Inspection (ISI)activities for1995wereperformed oncomponents withinClass1,2,3,HighEnergyPiping,SteamGenerator Tubes,SeismicSupportsandSnubbers. | |||
R. | ISIexaminations wereconcluded onMay4,1995.Examination methodsincludedVisual(VT),LiquidPenetrant (PT),MagneticParticle(MT),Ultrasonic (UT),Radiographic (RT),andEddyCurrent(ET).Functional Testing(FT)andSystemPressureTestswerealsoperformed. | ||
Erosion/Corrosion examinations werealsoperformed duringthistime.Personnel involvedincludedRG&ELaboratory andInspection | |||
: Services, SonicSystemsIncorporated, MasterLeeServicesCorporation, ABBCombustion Engineering Corporation, GinnaStationQualityControlandtheGinnaStationResults/Test Group.Additional SupportPersonnel includedindividuals fromthefollowing departments: | |||
GinnaStationInsulators, Maintenance, Electricians, PipeFitters,HealthPhysics,TurbineMaintenance, RG&EGeneralMaintenance andtheMechanical Engineering GroupoftheNuclearEngineering | |||
.Services Department. | |||
ASMESECTIONXISUMMARYOFWORKACCOMPLISHED: | |||
Uponconclusion ofthe1995Outage,56.14ofASMESectionXICoderequiredexaminations forthe,ThirdIntervalISIProgramhasbeencompleted. | |||
Adetailedcomponent summaryofalloutageISIactivities withtheirassociated resultscanbefoundwithin"Attachment I".CLASS1COMPONENTS: | |||
Atotalof38ASME,Augmented orOwnerElectedcomponents wereexamined. | |||
Theexaminations forthesecomponents consisted of2VT-3's,33PT's,and12UT's.Atotalof47examinations wereperformed onClass1Components. | |||
R.EGINNANUCLEARPORERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS1COMPONENTS: | |||
Cont.Class1examinations wereperformed onthefollowing items/systems and/orplantlines/component: | |||
ItemSstemDescritionPlantLineComonentCVCS-Charging System:Regenerative HeatExchanger: | |||
CVCS-Letdown System:HighPressureSafetyInjection System:Pressurizer: | |||
Pressurizer System:2-CH5-2501 2B-CH5-2501 2C-CH5-2502 2A-CH5-2501 2I-CH5-2502 ECH02C2A-CH4-2501 10A-SI2-2501-B 2A-SI2-2501 2B-SI2-2501 TRC013A-RC8-2501-A 3A-RC8-2501-B 3A-RC8-2501 3B-RC8-2501 3C-RC8-2501 4A-RC8-2501-A ReactorCoolantPumpBItems:ReactorCoolantSystem:ResidualHeatRemovalSystem:PRC01B31-RC-2501-A31-RC-2501-B27.5-RC-2501-A,2D-RCO-2501-B 2B-RCO-2501-B 10A-AC7-2501-B R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS2COMPONENTS: | |||
Atotalof63ASMEorOwnerElectedComponents wereexamined. | |||
Theexaminations forthesecomponents consisted of3VT-1's,30VT-3's,21PT's,10MT's,2RT's,8UT's,and2VT-2'sforatotalof76examinations. | |||
Class2examinations wereperformed onthefollowing items/systemsand/orplantlines/components: | |||
ItemSstemDescritionComonentPulsation Dampener: | |||
CVCS-Charging System:Feedwater System:HighPressureSafetyInjection System:Mainsteam System:SCH118A-CH-25022D-CH5-2501 2F-CH5-2501 14A-FW-900-1A 14B-FW-900-1B 10-SI-1518K-SI-151 4-SI-3014D-SI-1501 4E-SI-1501 3C-SI-1501 3E-SI-1501 30A-MS-600-1A 30B-MS-600-1B 6A-MS-600-1B 6B-MS-600-1A 6B-MS-600-1B ResidualHeatRemovalHeatExchanger: | |||
EAC02AResidualHeatRemovalSystem:StandbyAux.Feedwater System:10-AC-60110A-AC-601 6-'AC-6016B-AC-6016D-AC-6013C-FW-902S-1A REDGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS2COMPONENTS: | |||
Cont.ItemSstemDescritionPlantLineComonentServiceWaterSystem:8I-SW-125 8L-SW-125 8M-SW-125 6-SW-1256A-SW-125 6B-SW-125 6F-SW-125 6G-SW-125 CLASS3COMPONENTS:. | |||
Atotalof119ASMEorOwnerElectedComponents wereexaminedutilizing theVT-3visualtechnique. | |||
Examinations wereperformed onthefollowing items/systemsand/or'lant lines/components: | |||
ItemSstemDescritionPlantLineComonentAuxiliary CoolingSystem:Auxiliary Feedwater System:14B-AC5-15214C-AC5-15210G-AC5-15210H-AC5-15210I-AC5-1528B-AC6-1526C-AC6-1526E-AC6-1526G-AC6-1525A-FW7-900-1 4A-SW-125-1B4A-SW-125-1C3A-FW7-900-1A 3A-FW7-900-1B 3E-FW7-900-1 3G-FW7-900-1 3H-FW7-900-1 3J-FW7-900-1 2A-FW7-900-1B 2C'-FW7-900-1A 1-5A-FW7-900-1 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS3COMPONENTS: | |||
Cont.ItemSstemDescritionPlantLineComonentSealWaterHeatExchanger: | |||
DieselGenerator System:Mainsteam System:ECH045C-DG-A6A-MS-600-1 6C-MS-600-1 StandbyAux.Feedwater System:ServiceWaterSystem:HIGHENERGYCOMPONENTS: | |||
4A-FW8-152S-B 4G-SWO-152S 4F-SWO-152S 3A-FW8-902S-A 3A-FW8-902S-B 3C-FW8-902S 14D-SWO-125-1 14E-SWO-125-1 14G-SWO-125-1 14H-SWO-125-1 10B-SWO-125-1 6H-SWO-125-1 Nineteen(19)Augmen'ted orOwnerElecteditemsassociated withtheHighEnergyProgramwereexaminedduringthe1995Outage.Theexaminations fortheseitemsconsisted of15VT-1's,3VT-3's,16MT's,8RT's,and7UT'sforatotalof49examinations. | |||
HighEnergycomponent examinations wereperformed onthefollowing items/systemsand/orplantlines:ItemSstemDescritionFeedwater System:Mainsteam System:PlantLine20-FW-900-1 14A-FW-900-1A 14B-FW-900-1 14B-FW-900-1B 36-MS-600-1 30A-MS-600-1 30B-MS-600-1 24B-MS-600-1A REDGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)STEAMGENERATOR TUBING:EddyCurrentASMEandOwnerElectedExaminations wereperformed ontubesinthe"A"and"B"SteamGenerators. | |||
Thefollowing EddyCurrentexaminations wereperformed duringthe1995Outage:2.OpenGenerator Tubes,Previousindications greaterthanorequalto204wereexaminedtotheextentofdegradation asaminimum.OpenGenerator Tubes,204RandomSampleofallopenunsleeved tubeswereexaminedFullLength(F/L).3.OpenGenerator Tubes,100%ofallopenunsleeved tubeswereexaminedtothefirstSupportPlateontheHotLegsideasaminimum.4.SleevedGenerator Tubes,20%RandomSampleofeachtypeofsleevedgenerator tubeswereexaminedfromthesleeveendasaminimum.5.MRPCofallRow1U-BendsandRow2U-Bends.6.MRPCofRollTransition Regioninallopen,unsleeved tubes.7.Applicable WearIndications ColdLeg,TubesR1C10-R1C12.SteamGenerator EddyCurrentExamination detailsaredocumented intheRochester Gas&Electric1995SteamGenerator EddyCurrentFinalReport.SYSTEMPRESSURETESTS:Hdrostatic TestinNo10-YearISI(ASME)Hydrostatic testswereperformed duringthe1995Outage. | |||
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)SYSTEMPRESSURETESTS:Cont.LeakaeTestinAtotalofsixteen(16)ASMEorAugmented LeakageExaminations wereperformed. | |||
R.E. | TheLeakagetestsincluded; one(1)Class1,ReactorCoolantSystem(PT-7)examination, fourteen(14)Class2or3examinations, andone(1)HighEnergyMainsteam examination. | ||
I.Owner2.PlantFORMNIS- | Itshouldbenotedthatone(1)Class3examination waspartially completed duringthisrefueling outage.ASMESectionXIReuiredComonentsServiceInducedRe'ectable | ||
-EandedExaminations: | |||
TherewerenoASMESectionXIrequiredcomponents thatwereclassified as"ServiceInducedRejectable" thatneededCodeexpandedexaminations. | |||
SNUBBERPROGRAM:VisualExaminations: | |||
Atotalof23Snubbercomponent supportbaselineexaminations wereperformed duringthe1995outage.Snubbervisualexaminations wereperformed on'hefollowing items/systemsand/orplantlines:ItemSstemDescritionPlantLineAux.Feedwater System:3B-FW-900-lA3Z-FW7-900-1 3K-FW7-900-1 BlowdownSystem:CVCS-Letdown System:2C-MS-600-1B2A-CH4-151 2E-CH-601Feedwater System:14A-FW-900-1A 14B-FW-900-1B RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)SNUBBERPROGRAM:Cont.VisualExaminations: | |||
ItemSstemDescritionMainsteam System:PlantLine30A-MS-600-1A 30B-MS-600-1B 6A-MS-600-1 6B-MS-600-1A 6B-MS-600-1B Pressurizer System:6AP-RC-6023B-RC8-2501 StandbyAux.Feedwater System:3C-FW-902S-1A 3C-FW-902S-1B SteamGenerator B:EMS01BFunctional TestinAtotaloftwenty-three (23)snubberswereFunctionally Tested(FT)duringthe1995outage.Fromthesixteen(16)snubbersthatwereoriginally scheduled, twelve(12)weremechanical snubbersandfour(4)werehydraulic snubbers. | |||
Duetosnubberfailures, anexpansion wasperformed thatconsisted ofseven(7)additional snubbersthatwereFunctionally Tested.Scheduled SnubberFunctional Tests(FT)wereperformed onPlantLineslistedaboveunderSnubberVisualexaminations. | |||
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)SEISMICSUPPORTPROGRAM:Atotalofnine'(9)Augmented orOwnerElectedSeismicSupportswereexaminedutilizing theVT-3visualtechnique. | |||
SeismicSupportexaminations wereperformed onthefollowing items/systems and/orplantlines:ItemSstemDescritionPlantLineCVCS-Charging System:Mainsteam System:Pressurizer System:ResidualHeatRemovalSystem:StandbyAux.Feedwater System:ServiceWaterSystem:2T-CH-151 6D-MS-600-1A 6E-MS-600-1B 6F-MS-600-1B 8-RC-6013C-WD-151 | |||
.5F-CD-152S 10C-SWO-125-1 EROSIONCORROSION MINWALLPROGRAM:Atotalof96itemswereexaminedduringthe1995Outage.Thebreakdown ofthistotalisasfollows:ComonentTePipesElbowsReducersTeesExpansion JointsTotalNumber5134641 REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)EROSIONCORROSION MINWALLPROGRAMCont.Component thickness measurements wereperformed onthefollowing systems:DWGNOSYSTEMM-1M-2M-4AM-4BM-7AM-10M-10AM-10BM-10CM-11AM-15AM-15BM-16M-31M-41AM-41BM-75M-81M-88DM-90M-91M-105A/BF.W.PUMPDISCHARGE TO5A/BHEATERS5A/BF.W.HEATERSTOF.W.HEADERFEEDWATER CLEANUPTOCONDENSER FROM5A/BHPHEATERSFEEDWATER CLEANUPTOCONDENSER | |||
&CONDENSATE DEM.RINSEHEATERDRAINTANKDISCHARGE LOWPRESSUREDOWNCOMERS (WESTCONDENSER) | |||
LOWPRESSUREDOWNCOMERS TOL.P.H.(WESTCONDENSER) | |||
LOWPRESSUREDOWNCOMERS (EASTCONDENSER) | |||
LOWPRESSUREDOWNCOMERS TOL.P.H.(EASTCONDENSER) | |||
MSR1A&1B2NDPASSDRAINMSR1A4THPASSTO5AHEATERMSR1B4THPASSTO5AHEATERMSR1A&1B4THPASSTOCONDENSER MSR1A&1BTOHEATERDRAINTANK&CONDENSER 5AHPHEATERDRAINTO4ALPHEATER5BHEATERDRAINTO4BHEATERSTEAMEXTRACTION TO5A&5BHEATERSFEEDWATER DISCHARGE (TURBINEBLDG)S/GBLOWDOWNTOFLASHTANK(TURBINEBUILDING) | |||
FEEDWATER CLEANUP(CV-18)FEEDWATER CLEANUP(CV-19)HEATINGSTEAM10 RE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)Thestatements madeinthisreportandattachments arecorrectandtheexaminations andcorrective measurestakenconformtotheRulesoftheASMECode,SectionXI.Preparedby:FrankA.KlpackiDateISIEngineerMichaelJ.SaporitoDateManager,Laboratory andInspection | |||
: Services, Technical Performance andFieldInspections Certificate ofInservice InsectionI,theundersigned, holdingavalidcommission issuedbytheNationalBoardofBoilerandPressureVesselInspections andtheStateorProvinceofNewYorkandemployedbyTheHartfordSteamBoilerInsectionandInsurance Comanhaveinspected and/orverifiedthecomponents described withinthisreportandassociated Attachments duringthestatedreporting timeframe,andstatetothebestofmyknowledge andbelief,theOwnerhasperformed examination andcorrective measuresdescribed inthisReportinaccordance withtherequirements oftheASMECode,SectionXI.Furthermore, neithertheInspector norhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromorconnected withthisinspection. | |||
ReviewedBy:Picac'fCPANII'sSignature 7u5~Date11 S | |||
I.Owner2.PlantFORMNIS-1OWNERsSREPORTFORINSERVICE INSPECTIONS AsrequiredbythcProvisions ofthcASMECodeRulesRochester GasgElectricCor.89EastAve.Rochester N.Y.14649(NameandAddressofOwner)R.E.GinnaNuclearPowerPlant1503LakeRoadOntarioNY14519(NameandAddressofPlant)'.PlantUnit15.Commercial ServiceDateJul19707.Components Inspected 4.OwnerCertificate ofAuthorization (ifrequired) 6.NationalBoardNurnbcrforUnitNANAComponent orAppurtenance Manufacturer orInstaller Manufacturer orInstaller SerialNo.StateorProvinceNo.NationalBoardNo.(*)SEE"ATTACHMENT I"FORAPPLICABLE INFORMATION Note:Supplemental sheetsinformoflists,sketches, ordrawingsmaybcused,provided(1)sizeis8-1/2in.x11in.,(2)information initems1throughe6onthisrcportisincludedoneachshcct,and(3)eachshcctisnumberedandthenumberofsheetsisrecordedatthctopofthislorm.(12/86)Thisform(E0029)maybeobtainedfromthcOrderDept.,ASME,22LawDrive,Box2300,Fairfield, NJ07007-2300 FORMNIS-1.(Back)10.Applicable EditionsofSectionXI1986Addenda9.Inspection IntervalI'rom1990to1999NoII.AbstractofExaminations, Includealistofexaminations andastatcmcnt concerning statusofworkrequiredforcurrentinterval. | |||
(*)12.AbstractofConditions Noted.(*)13.AbstractofCorrective MeasuresRccommcnded andTaken.(*)Wecertifythatstatements madeinthisrcportarecorrectandtheexaminations andcorrective mcasurcstakenconformtotherulesofthcASMECode,SectionXI.Ccrtificatc ofAuthorization No.(ifapplicable) | |||
NAExpiration DateNADate24Jul1995SignedRochester GasdcElectricCoorationOwnerByCERTIFICATE OFINSERVICE INSPECTION I,theundcrsigncd, holdingavalidcommission issuedbythcNationalBoardofBoilerandPressureVesselInspectors andthcStateorProvinceofNewYorkandemployedbyHartfordSteamBoilerInsection8cInsurance Coman.ofHartfordCFhaveinspected thecomponents described inthisOwner'sReportduringthcperiodAPtoWM5~andstatethattothebestofmyknowledge andbelief,theOwnerhaspcrforrncd examinations andtakencorrective mcasurcsdescribed inthisOwner'sReportinaccordance withtheinspection planandasrequiredbythcASMECode,SectionXI.Bysigningthiscertilicate neithertheInspector norhisemployermakesanywarranty, expressed orimplied,concerning theexaminations andcorrcctivc measuresdcscribcd inthisOwner'sRcport.Furthermore, neithertheInspector norhisemployershallbcliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromorconnected withthisinspection. | |||
~~i+'5'..u~~Inspector's Signature Commissions NationalBoard,State,Province, andEndorscmcnts Date199SSEE<<ATTACHMENT I<<FORAPPLICABLE INFORMATION 0SiO RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.oommerci alServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT IA.CLASS1COMPONENTS tAlePRESSURIZER DRAWINGS'-4 SummaryExamItemNumberCategNumberComponent Component TypeNDEExam004700B-DB3.120SPLNASMESPRAYLINENOZ-INSRADSECTUT95-UT:NORECORDABLE INDICATIONS, 360DEGREESACCEPTABLE. | |||
004800B-FB5.40RC-1000-MSW-1 SAFEEND-TO-NOZZLE (SPRAYLINE)ASMEPTUT95-PT!INSIGNIFICANTS L=O,W=1/8,UP,1/16"ROUND.UT!NORECORDABLE 6GEOMETRYS IDGEOMETRY. | |||
>90%CODECOVERAGEOBTAINED-ACCEPTABLE. | |||
A2eREGENERATIVE HEATEXCHANGER CDRAWINGS: | |||
A-8ItemNumberB3.150Component Component TypeRHE-NlASMEVESSEL-TO-NOZZLE WELDNDEExamUT95-UT:NORECORDABLE INDICATIONS, UTLAMPERFORMED IN1986.APPROX.94%COVERAGEOBTAINED-ACCEPTABLE. | |||
NOTE:"COMPONENT TYPE"ISDEFINEDASFOLLOWSt"ASME"=ITEMREQUIREDBYASMESECTIONXICODE"AUG"=AUGMENTED PROGRAM-ITEMREQUIREDBYNRCCOMMITMENT "OE"=OWNERELECTED-NONMANDATORY EXAMINATIONS | |||
eReEe" | eReEe"GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT CLASS1COMPONENTS CONT~A3eREACTORCOOLANTSYSTEM-LOOP ADRAWINGS: | |||
A-3BSummaryExamNumberCategnItemNumberComponent Component TypeNDEExam011820B-JB9.12PL-FW-XII-LR (XIII)ASMELONGITUDINAL SEAMWELDUT95-UTNORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
GREATERTHAN90tCOVERAGEOBTAINED. | |||
RELIEFREQUESTTOBEGENERATED FORCASTMATERIAL. | |||
012100B-JB9.11PL-FW-VIPUMP(RCP-A)-TO-PIPE ASMEUTPT95-PT:NORECORDABLE EcINSIGNIFICANT INDICATIONS-L=33.5CWSW=2.10"UP-0.15"LONG.L=39.4CW,WNN0.45amDOWNROUND015"-ACCEPTABLE. | |||
UT:NORECORDABLE INDICATIONS ACCEPTABLE. | |||
)90%.A4~REACTORCOOLANTSYSTEM-LOOP BDRAWINGS: | |||
A-3FSummaryExamNumberCateg'013320B-JItemNumberComponent NDEComponent TypeExamUTPTB9.12.PL-FW-XI-LR (XV)ASMELONGITUDINAL SEAMWELD95-PTtINSIGNIFICANTS FABRICATION INDICATIONS | |||
-ACCEPTABLE. | |||
UT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
RELIEFREQUESTTOBEGENERATED DUETOCASTMATERIAL. | |||
013500=B-JB9.11PL-FW-XVELBOW-TO-PUMP(RCP-B) | |||
ASMEUTPT95-PTNORECORDABLE INDZCATIONS, SURFACECONDITIONING PERFORMED | |||
-ACCEPTABLE. | |||
UT:NORECORDABLE INDICATIONS | |||
<90'tCODECOVERAGEOBTAINED. | |||
RELIEFREQUESTTOBEGENERATED TOADDRESSCODECOVERAGEANDCASTMATERIAL-ACCEPTABLE. | |||
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberrorUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.A5.3-IN.PRESSURIZER SPRAYLINEDRAWINGS: | |||
A-10SummaryExamNumberCategItemNumberComponent Component TypeNDEExam015400B-JB9.21BSW-1PIPE-TO-ELBOW ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
019600B-JB9.21M-1PIPE-TO-REDUCER ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
019800B-JB9.21ANOZZLE-TO-PIPE ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
A6.2-IN.PRESSURIZER SPRAYLINEDRAWINGS: | |||
A-llSummaryExamItemNumberCategNumber024000B-JB9.40Component 14PIPE-TO-COUPLING Component TypeASMENDEExamPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
025300B-JB9.4021ELBOW-TO-PIPE ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
025400B-JB9.4022PIPE-TO-VALVE(297) | |||
ASMEPT95-PT$NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
R.E.GINNANUCLEARPOWERPLANT/ | : Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit,14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT~A7a3-IN.PRESSURIZER RELIEFLINEDRAWINGS: | ||
R.E. | A-12SummaryExamItemNumberCategNumber026600B-JB9.21Component Component TypeCASMEOEREDUCER-TO-VALVE(515) | ||
NDEExamPT95-PTsBASELINEEXAMINATION, NORECORDABLE INDICATIONS ACCEPTABLE-NOTE:CONSTRUCTION NDEONMAINTENANCE SUMMARYM95127.026700B-JB9.21DVALVE(515)-TO-PIPE OEPT95-PT:BASELINEEXAMINATION, NORECORDABLE INDICATIONS ACCEPTABLE. | |||
NOTE1CONSTRUCTION NDEONMAINTENANCE SUMMARYM95127.027000B-JB9.21BREDUCER-TO-VALVE(516) | |||
ASMEPT95-PT:BASELINEEXAM,NORECORDABLE INDICATIONS ACCEPTABLE. | |||
NOTE:CONSTRUCTION NDEONSUMMARYM95132Ec.MOVATSREPORT95-36.027100B-JB9.21CVALVE(516)-TO-PIPE ASMEPT95-PT:BASELINEEXAM,NORECORDABLE INDICATIONS ACCEPTABLE. | |||
NOTE:CONSTRUCTION NDEONSUMMARYM95132&MOVATSREPORTg95-36. | |||
R.E.GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5C.ommercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.AS.4-IN.PRESSURIZER RELIEFLINEDRAWINGS: | |||
A-13SummaryExamNumberCateg028200B-JItemNumberComponent B9.11QREDUCER-TO-ELBOW Component TypeASMENDEExamUTPT95-PT6UT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
100'tCOVERAGE. | |||
A9~RESIDUALHEATREMOVALTOLOOPBCOLDLEGDRAWINGS: | |||
A-14SummaryExamNumberCateg029100B-JItemNumberComponent Component TypeB9.11ASW-1ASMEPIPE-TO-ELBOW NDEExamUTPT95-PT6UT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
A10~H.P~SAFETYINJECTION LINETOLOOPBCOLDLEGDRAWINGS: | |||
A-16SummaryExamNumberCateg033800B-JItemNumberB9.11Component FSW-1PIPE-TO-ELBOW Component TypeASMENDEExamUTPT95-PT6UT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
GREATERTHAN90%COVERAGEOBTAINED. | |||
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.All.H.P,SAFETYINJECTION LINEDRAWINGSa A-19SummaryExamNumberCateg,038700B-JItemNumberB9.40Component FSW-19TEE-TO-REDUCER Component TypeASMENDEExamPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
041700B-JB9.40GSW-15ELBOW-TO-PIPE ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE A12~2"H.PSAFETYINJECTION TOLOOPBHOTLEGDRAWINGS: | |||
A-21SummaryExamNumberCategItemNumberComponent Component TypeExam042200B-JB9.40GSW-202"PIPE-TO-BRANCH CONNECTION ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
A13.2"LETDOWNTOREGENHTXDRAWINGS: | |||
A-23SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam044900B-JB9.4020ASMEPIPE-TO-ELBOW 95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
PT045425F-AF1.10RCVU-33GUIDEASME95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
R.E. | R.E.GZNNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | ||
0i | : Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT~AleSEALWATERTORCP-A,DRAWINGS: | ||
A-31SummaryExamNumberCateg049750B-JItemNumberComponent B9.4020ELBOW-TO-PIPE ASMEPTComponent TypeExam95PTREJECTf1/8ROUNDPOREfBLEEDOUT1/4ATFITTINGSIDE-TOEOFWELDORIGINALCONSTRUCTION, NCR95-030 GENERATEDS USEASIS~SURFACECONDITIONING PERFORMEDS POREREMOVED.PERFORMED VT&PTONCONDITIONED AREA,NORECORDABLE | |||
-ACCEPTABLE. | |||
049765B-JB9.4019PIPE-TO-ELBOW ASMEPT95-PT:NORECORDABLE INDICATIONS, GREATERTHAN90'tCOVERAGEOBTAINED, | |||
-ACCEPTABLE. | |||
A15e2"CHARGINGTOLOOPBCOLDLEGDRAWINGS: | |||
A-25SummaryExamNumberCateg050740F-AItemNumberF1.10VComponent CVU-6VARIABLESPRINGComponent TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS, TEMP.73DEGFSETTING5/8"=801'Sf-ACCEPTABLE. | |||
050745B-JB9.4021CTEE-TO-REDUCER ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
050750B-JB9.4022PIPE-TO-VALVE(295) | |||
ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
0i REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul19706.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.tA16~2"ALTERNATE CHARGINGTOLOOPACOLDLEGDRAWINGS: | |||
A-26SummaryExamNumberCategItemNumberComponent Component TypeNDEExam051400B-JB9.4020ASMEVALVE(392B)-TO-PIPEPTUT95-PT:WELDNORECORDABLE INDICATIONS | |||
-ACCEPTABLE VALVE(V392B)CASTINGSIDECONTAINSLARGEAMOUNTSOFPOROSITY(1/8TO3/8"),NOTSERVICEINDUCED.NCR95-033GENERATED. | |||
UTTHICKNESS PERFORMED, AVERAGE~600"~USE-AS-IS PERENGINEERING | |||
-ACCEPTABLE. | |||
ASME052500B-JB9.4030ELBOW-TO-PIPE 95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
PT052700B-JB9.4032PIPE-TO-COUPLING ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
A16.2"ALTERNATE CHARGINGTOLOOPBHOTLEGDRAWINGS: | |||
A-27SummaryExamNumberCateg054930B-JrItemNumberComponent NDEComponent TypeExamPTB9.409BASMEVALVE(9315)-TO-TEE 95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
054960B-JB9.409DASMETEE-TO-REDUCING INSERTPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
10 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial serviceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT~Ale2"ALTERNATE CHARGINGTOLOOPBHOTLEGDRAWINGS: | |||
A-27SummaryExamNumberCateg055300B-JItemNumberComponent B9.4012PIPE-TO-NOZZLE ASMEPTComponent TypeExam95-PTNORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
A18~REACTORCOOLANTPUMPBDRAWINGSNASummaryExamNumberCategItemNumberComponent Component TypeNDEExam058105FLYWHELRG-1.14RCP-BFLYWHEEL, EXPOSEAUGAREAS212-3D19156-Gol-02 PTUT95-PT&UT:EYWMINEDALLACCESSIBLE AREAS,NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
058120----BOLTRCP-BANCHORBOLTSOEBOLTSUT95UTNORECORDABLE INDICATIONS FORSTUDSLlL4fMlM4fNlfN3sN4~OTHERSTUDL4IS117LONG~REJECTSTUDN2fINDICATION AT19.2",SEENCR94-056 FORRESOLUTION, NOAPPARENTCHANGESINCE1994EXAM.-ACCEPTABLE 11 R.E~GINNANUCLEARPOWERPLANTZnservice Znspection Report1990-1999 Intervals SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnitjNAATTACHMENT IB~CLASS2COMPONENTS tBl.2"CHARGINGFROMREGENHTXDRAWINGS: | |||
A-25ASummaryExamNumberCategItemNumberComponent NDEComponent TypeExam050420C3.20CVU-60(IA)INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
050425---Fl.20ACVU-60ANCHOR(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
B2e2"ALTERNATE CHARGINGTOLOOPBHOTLEGDRAWINGS: | |||
A-27SummaryExamNumberCateg054625ItemNumberComponent Component TypeC3.20CVU-48(IA)OEINTEGRALATTACHMENT NDEExamPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
054630----F1.20ACVU-48ANCHOR(ZA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
12 | |||
RE~ | RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT~B3PULSEDAMPENERDRAWINGS: | |||
B-6SummaryExamNumberCateg075430F-AItemNumberComponent F1.20ACF-SlSUPPORT(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
075460F-AF1.20ACF-S2SUPPORT(IA)OEVT-395-VT-3:NORECORDABLE 6REJECTSLACKOFTHREADENGAGEMENT BY1THREADONNEHILTINUT,NOTSERVICEINDUCED.USE-AS-IS PERENGINEERING LETTERDATED5/25/95-ACCEPTABLE. | |||
075500C-CC3.20CF-Sl(IA).INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
075600C-CC3.20CF-S2(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
13 | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTinservice Inspection Report1990-1999 | ||
R.E~ | : Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970.6.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tB4eCHARGINGPUMPATOPULSEDAMPENERDRAWINGS: | ||
B-6SummaryExamNumberCateg077500F-AItemNumberComponent F1.20RCVU-411RIGIDRESTRAINT (IA)Component TypeOENDEExamVT-395-VT-3sNORECORDABLE | |||
&INSIGNIFICANTS POORWORKMANSHIP ONWELDREPORTEDON942074PTEXAMRECORD-ACCEPTABLE. | |||
077501C-CC3.20CVU-411(IA)INTEGRALATTACHMENT ASMEPTVT-195-PT:REJSPOORWELDWORKMANSHIP ONORIGINALWELD.NCR94-133 GENERATED. | |||
SURFCONDITIONED. | |||
VT-1:NORECORDABLE | |||
&INSIG:6"OF3/16"WELDROUGHONBACKSIDEPT:INSIGSIN6"OFWELDS11/4HASSLAGS&fINDICATIONS ON3LENGTHENACCEPTPERNCRREV2.B5~MAINSTEAMLOOPAOUTSIDECVDRAWINGS: | |||
B-9SummaryExamNumberCateg080900F-AItemNumberComponent F1.20VMSU-45VARIABLESPRINGOEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS. | |||
TEMP.106DEG.F.,NORTH=1935if'S(0.4"),SOUTH=2115f'S(0.6)ACCEPTABLE. | |||
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 Intervalf SecondPer'iod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS | |||
'ONT~B6aMAINSTEAMLOOPAATMOSPHERIC VENTDRAWINGS: | |||
B-9ASummaryExamNumberCateg083850C-F-2ItemNumberComponent C5.51G2-BC-2-B FLANGE(3507)-TO-PIPE NDEComponent TypeExamASMEVT-1MTRT95-VT-1&MT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
RT:NORECORDABLE | |||
&INSIGNIFICANTS 5-10POROSITYAT71/2Ž0.031"-ACCEPTABLE. | |||
084320F-AF1.208MSU-58MECHANICAL SNUBBEROEVT-395VT3BASELINEEXAMTEMP~75DEG~FfSETTING31/8fPSA-35"STROKESS/N18187.NORECORDABLE INDICATIONS ACCEPTABLE. | |||
B7~MAINSTEAMLOOPBOUTSIDECVDRAWINGS: | |||
B-10SummaryExamNumberCateg088830F-AItemNumberComponent F1.20RMSU-33GUIDE(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
088835C-CC3.20MSU-33(IA)INTEGRALATTACHMENT OEMT95-MT!NORECORDABLE INDICATIONS | |||
&LIMITATIONSS ONLY50'tOFINTEGRALATTACHMENT WELDISACCESSIBLE DUETOASBUILTCONFIGURATION LIMITS-ACCEPTABLE. | |||
15 | |||
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commeccial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT~!BS~MAINSTEAMLOOPBTOAUXFWPUMPTURBINEDRAWINGS: | |||
B-10SummaryNumberExamCategItemNumber090300C-F-2C5.51Component L2-BC-1-A PIPE-TO-VALVE(3504) | |||
Component TypeASMENDEExamRTVT-1MT95-MT:NORECORDABLE. | |||
VT-1:NORECORDABLE | |||
&INSIGNIFICANTS SLIGHTRUST&WELDPREP.RT:INSIGNIFICANTs SLAG,POROSITYS INTERNALCONCAVITY | |||
-NOCHANGESINCELASTEXAMINATION ACCEPTABLE. | |||
B9~MAINSTEAMLOOPBATMOSPHERIC VENTDRAWINGS: | |||
B-10SummaryExamNumberCateg090820F-AItemNumberComponent F1.20SMSU-55MECHANICAL SNUBBERComponent TypeOENDEExamVT-395VT3BASELINEEXAMTEMP~74DEG~F~5SETTING213/16PSA-35"STROKE,S/N18195'.NORECORDABLE INDICATIONS ACCEPTABLE vB10.FEEDWATER LOOPAINSIDECVDRAWINGS! | |||
B-12SummaryExamNumberCategItemNumberComponent Component TypeNDEExam093100F-AF1.20VFWU-2VARIABLESPRINGOEVT-395-VT-3:TEMP.65DEG.F.,SETTING2126ig'S.NORECORDABLE | |||
&INSIGNIFICANTs LACKOFTHREADENGAGEMENT ONUPPERHANGERANCHOR&UPPERHANGERRODBENT.ACCEPTABLE PERNCRS83-132&92-147.093700C-F-2C5.51DD5PIPE-TO-ELBOW ASMERTMTVT-195-VT-1&MT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE RT:NORECORDABLE | |||
&INSIGNIFICANTs TUNGSTENQ305/8(1/32)5NOCHANGESINCELASTEXAMINATION | |||
-ACCEPTABLE. | |||
16 | |||
ReEGINNANUCLEARPOWERPLANTZnse& | ReEGINNANUCLEARPOWERPLANTZnse&iceInspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6~Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tBll~FEEDWATER LOOPBOUTSIDECVDRAWINGS'-14 SummaryExamNumberCateg095200F-AItemNumberComponent Fl.20RFWU-45RIGIDRESTRAINT Component TypeOENDEExamVT-395-VT-3:NORECORDABLE 6INSIGNZFICANTS RESTRAINT BODYREVERSED-ACCEPTABLE. | |||
B12.FEEDWATER LOOPBINSIDECVDRAWINGS: | |||
B-130NumberCateg098100F-ASummaryExamItemNumberComponent F1.20VFWU-11VARIABLESPRINGOEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS, TEMP.69DEGF.fSETTING1/2"=2315=g'Sf-ACCEPTABLE. | |||
B13.RESIDUALHEATREMOVALTOLOOPBCOLDLEGItemNumberComponent DRAWINGS: | |||
B-17SummaryExamNumberCateg108450F-AComponent TypeExamVT-3F1.20APEN111ANCHORANCHOR(IA)OE95-VT-3-NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
108451C-CC3.20PEN111ANCHOR(IA)ASMEINTEGRALATTACHMENT 95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
PT17 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commeucial ServiceDate~Jul1970B.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONTB14e6-IN,RESIDHTREMOVALTORPV(LHSI)DRAWINGSt B-17SummaryExamNumberCateg110650F-AItemNumberComponent F120RRHU-9RIGIDSUPPORT(IA)NDEComponent TypeExamOE95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 110655C-CC3.20RHU-9(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE B15aHP.SAFETYINJECTION FROMRHRDRAWINGS! | |||
B-19SummaryExamNumber~Categ120700C-F-1ItemNumberComponent 5REDUCER-TO-CROSS Component TypeOENDEExamPTUT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
UT:NORECORDABLE INDICATIONS fcGEOMETRY-ACCEPTABLE. | |||
GREATERTHAN90'tCOVERAGEACHIEVED. | |||
B16.H.P.SAFETYINJECTION LINE8K-SI-151 DRAWINGS: | |||
B-19SummaryExamNumberCateg124200F-AItemNumberComponent F1.20RRHU-102RIGIDSUPPORT(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
124202C-CC3.20RHU-102(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
18 | |||
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
R.E. | : Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial ServiceDate~Jul1975S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tB17eRESIDUALHEATREMOVALFROMLOOPAHOTLEGDRAWINGS: | ||
RE~ | B-20ASummaryNumber135350ExamItemCategNumberComponent F-AF1.20APEN140ANCHOR(IN/OUT)ANCHOR(IA)Component TypeOENDEExamVT-395-VT-3-NORECORDABLE INDICATIONS | ||
R. | -ACCEPTABLE 135351C-CC3.20PEN140ANCHOR(IA)(IN/OUT) | ||
INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS OTHER:APPROX.1/8imOFWELD6THE1/2"INSPECTION AREAOUTSIDEOFTHETOEARENOTINSPECTABLE DUETOTHEINSTALLATION OFSTRONGBACK.APPROX.82%COVERAGEACHIEVED. | |||
B18.RESIDUALHEATREMOVALTOLOOPBCOLDLEGDRAWINGS: | |||
B-25SummaryExamNumberCateg145885F-AItemNumberComponent Fl.20RRHU-55RIGIDSUPPORT(IA)'EVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 145890C-CC3.20RHU-55(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
19 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.Plant,R.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~cul197CS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.!B19eRESIDUALHEATREMOVALLINE6D-AC-601 DRAWINGS: | |||
B-26SummaryExamNumberCateg147900F-AItemNumberComponent F1.20ARHU-95ANCHOR(IA)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
147910C-CC3.20RHU-95(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE SUCCESSIVE EXAM.B20~RESIDUALHEATREMOVALLINE6B-AC-601 DRAWINGS: | |||
B-25SummaryExamNumberCateg151100F-AItemNumberComponent Component TypeF1.20RRHU-49OERIGIDSUPPORT(IA)NDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 151120C-CC3.20RHU-49(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE B21,RESIDUALHEATREMOVALTOLOOPBCOLDLEGDRAWINGS: | |||
B-25SummaryExamNumberCateg151700C-F-1ItemNumberComponent 1TEE-TO-PIPE Component TypeOENDEExamPTUT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
UT:NORECORDABLE INDICATIONS 6GEOMETRY-ACCEPTABLE. | |||
GREATERTHAN90'tACHIEVED. | |||
20 S | |||
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul197CS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.B22.H.P.SAFETYINJECTION PUMPASUCTIONLINEDRAWINGS: | |||
B-16BSummaryNumberExamCategItemNumberComponent Component TypeNDEExam160750F-AF1.20VRHU-118VARIABLESPRINGOEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
TEMP.110DEG.F~,SETTING9/16"=183g'S.RE-EXAMREQUIREDPERNCR94-024. | |||
B23.H.P.SAFETYINJECTION LINE4D-SI-1501 DRAWINGS: | |||
B-38SummaryNumberExamCateg161520F-AItemNumberComponent F1.20RSIU-41RIGIDRESTRAINT Component TypeOENDEExamVT-395-VT-3:SUCCESSIVE OWNERELECTEDEXAM,NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
B24.H.P.SAFETYINJECTION LINE3C-SI-1501 DRAWINGS: | |||
B-41SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam163020F-AF1.20RSIU-85RIGIDSUPPORT(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
SUCCESSIVE EXAM.163021C-CC3.20SIU-85(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
SUCCESSIVE EXAM21 eR.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial serviceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONTtB25.H.P.SAFETYINJECTION LINE3E-SI-1501 DRAWINGS: | |||
B-42SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam163720F-AF1.20RSIU-62GUIDE(IA)OEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
163721C-CC3.20SIU-62(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
B26.H.P.SAFETYINJECTION LINE4E-SI-1501 DRAWINGS: | |||
B-42SummaryExamNumberCateg163890C-F-1ItemNumberComponent C5.2128PIPE-TO-ELBOW ASMEPTUTNDEComponent TypeExam95-PT:INSIG-ROUNDINDICATION 1/32"DIA.L=87/8,CENTEROFWELDUT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
GREATERTHAN90%COVERAGEOBTAINED. | |||
164180C-F-1C5.2147ELBOW-TO-PIPE ASMEPTUT95-PT6UT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
22 0 | |||
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnitjNAATTACHMENT ICLASS2COMPONENTS CONT~B27eRESIDUALHEATEXCHANGER ADRAWINGS: | |||
B-109SummaryExamNumberCateg169041C-BItemNumberC2.33Component INSRHE-1A INLETNOZZLE-TO-SHELL WELDComponent TypeASMENDEExamVT-295-VT-2:TAKINGCREDITFOREXAMPERFORMED UNDERSUMMARYNUMBER413400IN1993,TESTWASACCEPTABLE. | |||
169051C-BC2.33ONSRHE-1A ASMEOUTLETNOZZLE-TO-SHELL WELDVT-295-VT-2:TAKINGCREDITFOREXAMPERFORMED UNDERSUMMARYNUMBER413400IN1993,TESTWASACCEPTABLE. | |||
B289SERVICEWATERLINE6G-SW-125 DRAWINGS: | |||
B-50SummaryNumberExamCategItemNumberComponent NDEComponent TypeExam173020C-F-2*3OEREDUCINGELBOW-TO-PIPE MTUTVT-195-VT-1:INSIGSSURFACERUST6CORROSION OVERFULLPIPEAREA.RANDOMPITTING.MT:NORECORDABLE INDICATIONS. | |||
UT:NORECORDABLE INDICATIONS | |||
&GEOMETRY. | |||
UT:WALLTHICKNESS | |||
.246"ACCEPTABLE PERMECH.ENG.DESIGNANALYSISDA-ME-95-003. | |||
WELDACCEPTABLE. | |||
23 ReE.GZNNANUCLEARPOWERPLANTrInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6~Commercial ServiceDate~Jul1970B.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tB29eSERVICEWATERLINEBM-SW-125 DRAWINGS! | |||
B-50ASummaryNumberExamItemCategNumberComponent NDEComponent TypeExam173350---F1.20RSWU-78GUIDEOEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
&OTHERN'HIM (3"X1/2"X4")WELDEDINPLACEWITH3/16"FILLETWELDONEASTANDWESTSIDES.ACCEPTABLE PERME-121.NOINTEGRALATTACHMENT B30.SERVICEWATERLINE6F-SW-125 SummaryExamItemNumberCategNumberComponent 173505---F1.20APEN308ANCHORIII)ANCHOR(ZA)DRAWINGS: | |||
B-50ANDEComponent TypeExam(TYPEOEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
173506----C3.20PEN308ANCHOR(IA)(TYPE ZII)INTEGRALATTACHMENT OEMT95-MTNORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
B31,SERVICEWATERLINE8L-SW-125 DRAWINGS: | |||
B-50ASummaryNumber173530ExamCategItemNumberC-F-2*Component 43TEE-TO-PIPE Component TypeOENDEExamMTUTVT-195-VT-1:NORECORDABLE INDICATIONS | |||
&INSZG:MINORPITTINGONBASEMETAL.MISALIGNMENT BETWEENPIPE&TEE.TEEODISLARGERTHANPIPE1/16"TO1/8"-ACCEPTABLE. | |||
MT:NRZ-ACCEPTUT:NRI&GEOMETRY-ACCEPTABLE. | |||
GREATERTHAN90'tACHIEVED. | |||
24 R.E~GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthoriration (IfReq.)~NAS.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONTtB32~SERVICEWATERLINESI-SW-125 DRAWINGSsB-51CSummaryExamNumberCategItemNumberComponent Component TypeExam174140C3.20SWU-64(IA)INTEGRALATTACHMENT OEMT95-MT$NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
174150---F1.20RSWU-64GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE B33.SERVICEWATERLINE6B-SW-125 DRAWINGS'-52B SummaryExamNumberCateg175205ItemNumberComponent F1.20APEN315ANCHOR(TYPEIII)ANCHOR(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 175206----C3.20PEN315ANCHOR(IA)(TYPE III)INTEGRALATTACHMENT OEMT95-MT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
25 RaE.GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999 | |||
: Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197D6.'National BoardNumberforUnitjNA~ATTACHMENT ICLASS2COMPONENTS CONTB34.SERVICEWATERLINE6A-SW-125 DRAWINGS: | |||
B-53SummaryNumber175310ExamCategItemNumberComponent, C-F-2*3REDUCINGELBOW-TO-PIPE Component TypeOENDEExamMTUTVT-195VT1NRI5ZNSIG6OTHERNRANDOMPITTING(SEEEXAMSHEET),MEDIUMRUST-ACCEPTABLE MT!NRI6OTHER;RANDOMPITTING,NOWELDDEFECTSFOUND-ACCEPTABLE. | |||
UT.NORECORDABLE INDICATIONS 6GEOMETRY-ACCEPTABLE. | |||
GREATERTHAN90'tACHIEVED. | |||
175325OEF1.20APEN312ANCHOR(TYPEIII)ANCHOR(IA)95-VT-3tNORECORDABLE | |||
&INSIGNIFICANTS VENTLINEISEMBEDDEDINCONCRETE-ACCEPTABLE VT-3175326----C3.20PEN312ANCHOR(IA)(TYPE III)INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
B35.SERVICEWATERLINE6-SW-125DRAWINGS: | |||
B-53ASummaryNumberExamCategItemNumberComponent'omponent TypeNDEExam175885Fl.20APEN323ANCHOR(TYPEOEIII)ANCHOR(IA)VT-395-VT-3sNORECORDABLE 6INSIGNZFICANTB VENTLINEEMBEDDEDZNCONCRETE-ACCEPTABLE. | |||
175886----C3.20PEN323ANCHOROE(IA)(TYPE III)INTEGRALATTACHMENT 95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
PT26 0 | |||
R.EeGINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester GasfElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfReq.)~NAB.Commercial BerviceDate~Jul19706.National BoardNumberforUnitN~AATTACHMENT ICLASS2COMPONENTS CONT~tB36.STANDBYAUXFWTHRUPEN119TOAS/GFWHDINCVDRAWINGS: | |||
C-20SummaryExamNumberCateg176120ItemNumberComponent F1.20RAFU-217(AFW-19)GUIDE(IA)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
176121---C3.20AFU-217(AFW-19)(IA)OEINTEGRALATTACHMENT 95-MT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
MT27 | |||
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
R.E~ | : Interval, SecondPeriodfThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntario-NY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT IC.CLASS3COMPONENTS: | ||
Cl.SEALWATERHEATEXCHANGER DRAWINGS: | |||
B-4SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam073150F1.40SlSUPPORTLEGSiOEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 073160----F1.40S2SUPPORTLEGP2OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
e073200----D2.20SlSUPPORTLEG$1-IAOEPT95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
073300----D2.20S2OESUPPORTLEGg2-IA95-PT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
PTC2~DIESELGENERATOR AJSW.COOLINGRETURNDRAWINGStC-35SummaryExamNumberCategItemNumberComponent Component TypeNDEExam500120D-BD2.20DG-1A(IA)ASMEVT-3INTEGRALATTACHMENT 95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:NODRAWINGAVAILABLE | |||
-3/16"FILLETWELDS.500125F-AF1.30RDG-1ARIGIDSUPPORT(IA)OEVT-395-VT-3NORECORDABLE INDZCATIONS | |||
-ACCEPTABLE. | |||
NOTE:NODRAWINGAVAILABLE. | |||
28 0 | |||
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfReq.)~NAB.Commercial ServiceDate~Jul1970B.National BoardNumberforUnitjNAATTACHMENT ICLASS3COMPONENTS CONTtC2.DIESELGENERATOR AJ'.W.COOLINGRETURN(Cont.)SummaryExamNumberCateg500130D-BItemNumberComponent D2.20DG-2A(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE NOTE:NODRAWINGAVAILABLE, 3/16"FILLETWELDS.500135F-AF1.30RDG-2ARIGIDSUPPORT(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:NODRAWINGAVAILABLE. | |||
C3.AUX'OOLING WTReFROMNON-REG.HT.EXCH.DRAWINGS'-3 SummaryExamNumberCateg500320F-AItemNumberComponent F1.30RCCU-106RIGIDRESTRAINT OENDEComponent TypeExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
INSIG:CHIPPEDPAINT-ACCEPTABLE. | |||
OWNERELECTEDEXPANDEDEXAMFORNCR94-129 | |||
&fNCR94-130. | |||
500360F-AF1.30RCCU-110RIGIDHANGEROEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
OWNERELECTEDEXPANDEDEXAMFORNCR94-129 | |||
&NCR94-130 500370F-AF1.30RCCU-111RIGIDHANGEROEVT-395-VT-3:NORECORDABLE INDICATIONS-ACCEPTABLE. | |||
NOTE:2LUGSONEITHERENDOFU-BOLTLUGSAPPEARTOBEOLDSADDLESCUT-OUT,APPROX.3/4TO1"LONGW/3/16"FILLETWELDSASANINTEGRALATTACHMENT-ACCEPTABLE. | |||
OEEXPANDEDEXAMFORNCR94-129 | |||
&6NCR94-130. | |||
29 | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~C4~COMPeCOOL.HT.EXCHS.TO RESIDUALHT.EXCHS~DRAWINGStC-4SummaryNumberExamCateg500530D-BItemNumberComponent Component TypeD2.20CCU-138(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3:NORECORDABLE 66INSIGSLUGI3UNDERSIZE WELD4"(1/8"FILLET)FROMTOPTOBOTTOM.LUG/4UNDERSIZE WELD71/2TO8FROMTOPS<1/16f1/2INLENGTHUNDERCUT84"FROMTOP1"INLENGTH<1/32meOKPERENG.ORIGINALCONSTRUCTION | |||
-ACCEPTABLE. | |||
F1.30RCCU-138GUIDE(IA)OEVT-395-VT-3:NORECORDABLE 66INSIGNIFICANTS PAINTEDSURFACE,SLIGHTRUST-ACCEPTABLE. | |||
500610D-BD2.20CCU-146(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
500615F-AF1.30RCCU-146GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
CS~COMP~COOL.PMPS.SSUC.FM RES.HT~EX'6SG.TKDRAWINGS: | |||
C-6SummaryExamNumberCategItemNumberComponent Component TypeNDEExam500760D-BD2.20CCU-156(IA)OEINTEGRALATTACHMENT VT-3MT95-VT-3$NORECORDABLE INDICATIONS | |||
-ACCEPTABLE'T NORECORDABLE INDICATIONS, AUGMENTED EXAM.-ACCEPTABLE. | |||
OWNERELECTEDEXPANDEDEXAMFORNCR94-124. | |||
30 R.E~GZNNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearpowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfReq.)~NAB.oommeccial BerviceDate~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS | |||
.CONT.C5~COMP.COOL.PMPS.,SUC.FM RES.HT.EX. | |||
&SG.TK(Cont.)SummaryNumberExamCateg500765F-AZtemNumberComponent F1.30RCCU-156RIGIDSUPPORT(IA)OEVT-3NDEComponent TypeExam.95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
INSIG:1/8"SHIMONWESTSIDE6NORTHWESTCORNEROFSUPPORTACCEPTABLE OWNERELECTEDEXPANDEDEXAMFORNCR94-124 500770D-BD2.40CCU-158(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE INSIG:LIGHTRUST,SOMECHIPPEDPAINT-ACCEPTABLE. | |||
500775F-AF1.30VCCU-158VARIABLESPRING(IA)OEVT-3VT-395-VT-3:REJ:OWNERELECTEDEXAM,W.SPRINGCANUPPERATTACHLOOSENUT,SPACERMISSINGONLOWERE.SIDEOFCLAMP.SPRINGCANSOFFSCALE.NCR94-124 GENERATED-SERVICE INDUCEDVT3REEXAMfNRI6INSIGTEMP~73DEGF6SETTING1333gSE.E<W.-ACCEPT. | |||
500780F-AF1.30RCCU-159RIGIDRESTRAINT OEVT-3UT95-OEEXPANDED'OR NCR94-124. | |||
VT-3:OESERVICEINDUCEDREJDEFORMATION N.ATTACHUPPERBOLT,LOWERBOLTPULLEDOUT.NCR94-125 GENERATED. | |||
VT-3:RE-EXAMREJ:S.PLATELIFTED5/32".UT:AUG.EXAM.,4BOLTS6"LONG.USE-AS-IS PERREV.NCR94-125. | |||
500790D-BD2.40CCU-160(IA)INTEGRALATTACHMENT OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
OWNERELECTEDEXPANDEDEXAMFORNCR94-124. | |||
31 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.tC5.COMP.COOL.PMPS., | |||
SUC.FMRES.HT.EX. | |||
&SG.TK(Cont.)SummaryExamNumberCateg500795F-AItemNumberComponent F1.30VCCU-160VARIABLESPRING(IA)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
TEMP.=69DEG.F.,SETTING=5/8"=1832f'SOWNERELECTEDEXPANDEDEXAMFORNCR94-124. | |||
500800F-AF1.30VCCU-165VARIABLESPRINGOEVT-3VT-395-EXPANDED FORNCR94-125. | |||
VT-3:OWNERELECTEDSERVICEZNDUCEDREJECT,LOOSENUTTURNS<1/8TURN.NCR94-129 GENERATED. | |||
VT-3:RE-EXAM,NORECORDABLE INDICATIONS ACCEPTABLE. | |||
500810F-AF1.30RCCU-166RIGIDRESTRAINT OEVT-3VT-395-EXPANDED FORNCR94-125. | |||
VT-3:OWNERELECTEDSERVICEINDUCEDREJECT:LOOSEBOLT,4NUTSLOOSEONHZLTIBOLTS.PLATEAWAYFROMWALL1/8",THRDRODNOTININSPECTION PORTBY1/2"fTHRDSDAMAGE.NCR94-130 GEN.VT-3:RE-EXAM,-NORECORDABLE INDICATIONS. | |||
500820D-BD2.40CCU-167(IA)INTEGRALATTACHMENT OEVT-3VT-395-OWNERELECTEDEXPANDEDFOR'CR94-124 VT-3:ORIGINALCONSTRUCTION REJ:ITEMg8WELDMISSINGOVERPIPETOELBOWWELD.ESIDE1/2",WSIDE5/8".NCR94-131 GENERATED. | |||
VT-3:RE-EXAM,INSIG:LIGHTTOMODERATERUST.USE-AS-ZS PERNCR94-131. | |||
32 | |||
RE~ | RE~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6Co.mmercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.CS.COMP.COOL.PMPS.,SUC.FM RES.HT.EX.& | |||
SG.TK(Cont.)SummaryExamNumberCateg500825F-AItemNumberComponent F1.30VCCU-167VARZABLESPRING(IA)Component TypeOENDEExamVT-3VT-395-EXPANDED FORNCR94-124. | |||
VT-3!OWNERELECTEDEXPANSION SERVICEINDUCEDREJ:SETTINGOUTOFWORKINGRANGET/C002594GENERATED. | |||
VT-3:RE-EXAMAFTERRESETTING, NORECORDABLE INDICATIONS, TEMP.73DEG.F.,SETTING13/32"29481'S-ACCEPTABLE. | |||
F1.30RCCU-168GUIDEOEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE OWNERELECTEDEXPANDEDEXAMFORNCR94-129 | |||
&NCR94-130-500840D-BD2.40CCU-169(IA)INTEGRALATTACHMENT OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
INSIG:MODERATERUST-ACCEPTABLE. | |||
OWNERELECTEDEXPANDEDEXAMFORNCR94-124. | |||
500845F-AF1.30VCCU-169OEVARIABLESPRING(IA)95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
TEMP.69DEGF.fSETTING7/8"=2013g'S.OWNERELECTEDEXPANDEDEXAMFORNCR94-124 VT-3500850D-BD2.20CCU-170(IA)INTEGRALATTACHMENT OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 | |||
&NCR-130.VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
I33 | |||
ReE. | ReE.GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceData~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.C5.COMP.COOL.PMPS.,SUC.FM RES.HT.EX.& | |||
SG.TK(Cont.)SummaryExamNumberCateg500855F-AItemNumberComponent F1.30RCCU-170GUIDE(IA)Component TypeOENDEExamVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 | |||
&NCR94-130. | |||
VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE C6.AUX.COOL. | |||
IN&OUTFORBORICACIDEVAPOReDRAWINGS! | |||
C-7SummaryExamNumberCateg500910D-BItemNumberComponent D220CCU-128(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE INSIGLIGHTTOMODERATERUST.NOSPECIFICATIONS FORWELDREINFORCEMENT, INTEGRALATTACHMENT ABANDONED INPLACEACCEPTABLE 500915F-AF1.30RCCU-128GUIDE(IA)OEVT-395-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
501000F-AF1.30RCCU-161GUIDEOEVT-395-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
OWNERELECTEDEXPANDEDEXAMFORNCR94-129 | |||
&NCR94-130. | |||
501010F-AF1.30RCCU-162RIGIDRESTRAINT OEVT-395-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
OWNERELECTEDEXPANDEDEXAMFORNCR94-129 | |||
&NCR94-130. | |||
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial BecviceDate~cul197DB.National BoardNumberforUnitNjaATTACHMENT ICLASS3COMPONENTS CONT~C6.AUX.COOL. | |||
IN&OUTFORBORICACIDEVAPOR.(Cont.)SummaryExamNumberCateg501030D-BItemNumberComponent D2.20CCU-164(IA)INTEGRALATTACHMENT NDEComponent TypeExamASME95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
501035F-AF1.30ACCU-164ANCHOR(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
C7~AUX~COOLWTRFROMPEN124f125f126Et130DRAWINGS: | |||
C-5SummaryExamNumberCateg501140F-AItemNumberComponent F1.30RCCU-231RIGIDHANGERComponent TypeOENDEExamVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 6NCR94-130. | |||
VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
501150F-AF1.30RCCU-232RIGIDRESTRAINT OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 6NCR94-130. | |||
VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
501160F-AF1.30RCCU-233RIGIDRESTRAINT OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 6NCR94-130. | |||
VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
35 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.C8.SWCOMP.COOLeRSP.FUELPITHTEXSesDZSCH DRAWINGS:" | |||
C-11SummaryExamNumberCateg501660D-CItemNumberD3.20Component Component TypeSWU-164(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 501665F-AF1.30RSWU-164OERIGIDHANGER(IA)95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
VT-3C9~SVC.WTR~-TOCOMP~COOL~&SP.FL.PIT HT.EX'RAWINGS iC-12SummaryExamNumberCategItemNumberComponent Component TypeNDEExam501870D-CD3.20SWU-191(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3tNORECORDABLE INDICATIONS 6INSIGNIFICANT; MODERATERUSTONPIPE-ACCEPTABLE. | |||
501875F-'AF1.30RSWU-191OERIGIDSUPPORT(IA)95-VT-3:NORECORDABLE INDICATIONS 6INSIGNIFICANT MODERATERUST.DRAWINGDOESNOTMATCHSUPPORTITEMSfl6f5.OLDEcCUT-OFFLUGSREMAIN,DCRGENERATED | |||
-ACCEPTABLE VT-3501890D-CD3.20SWU-193(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
36 R.E~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6C.ommercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONTC9.SVC.WTR.-TO COMP.COOL.&SP.FL.PIT HT.EXS.(Cont.)SummaryExamNumberCateg501895F-AZtemNumberComponent Fl.30RSWU-193RIGIDHANGER(ZA)Component TypeOENDEExamVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE C10.SVC.WTR.-TO A&BDIESELGENeWTReCOOLERS DRAWINGS: | |||
C-13SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam502270D-BD2.20SWU-251(IA)ASMEVT-3INTEGRALATTACHMENT 95-VT-3!NORECORDABLE INDICATIONS | |||
&INSIGNIFICANTS LIGHTRUSTONTHEINTEGRALATTACHMENT | |||
-ACCEPTABLE. | |||
502275F-AF1.30RSWU-251RIGIDSUPPORT(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
&INSIGNIFICANT ITEMg2BASEPLATEISCOVEREDWITHAHEAVYCOATOFPAINTANDCANNOTBESEEN-ACCEPTABLE. | |||
ClioSVC.WTR.-INTMD.BLDG.16"HD.TO PEN312-320DRAWINGS: | |||
C-16BSummaryExamNumberCateg502960D-B95-VT-3:NOItemNumberComponent NDEComponent TypeExamVT-3D2.20SWU-340(IA)ASMEINTEGRALATTACHMENT RECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
502965F-AF1.30RSWU-340OERIGIDHANGER(IA)f95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:ITEMf3FILLETWELDTOBEAM=3/16".ITEMill,4SEPARATEFILLETWELDSAREACCORDING TODRAWING.VT-337 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503.LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul197C6.National NoavdNumberforUnitjNAATTACHMENT ICLASS3COMPONENTS CONT.C12~SVC.WTR.-INTMD.BLDG.14"HD.TO CHILL.ASBDRAWINGS: | |||
C-16BSummaryExamNumberCateg503000D-BItemNumberComponent D2.20SWU-344(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
503005F-AFl.30RSWU-344RIGIDRESTRAINT (IA)ASMEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE COLS/NC13~SVCeWTR~PUMPSAfBfC6DDISCH~SCR~HOUSEDRAWINGS'-17 SummaryExamNumberCateg503445F-AItemNumberComponent F1.30RSWU-630(N741)GUIDEComponent TypeOENDEExamVT-395-VT-3:BASELINEEXAMFOREWR5284BV4604REPLACEMENT. | |||
NORECORDABLE EcINSIGNIFICANTf IMPROPERCLEARANCEf NOGAPfACCEPTABLE PERME-121-ACCEPTABLE. | |||
503480D-BD2.20SWU-634(N745)(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3:BASELINEEXAMFOREWR5284BV4604REPLACEMENT. | |||
NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:ADDITIONAL EXAMINATIONS PERFORMED INCLUDEDVT-16MT-ACCEPTABLE 503485F-AF1.30RSWU-634(N745)RIGIDSUPPORT(IA)ASMEVT-395-VT-3:BASELINEEXAMFOREWR5284BV4604REPLACEMENT. | |||
NORECORDABLE 6INSIGNIFICANTf ANCHORBOLTSACCEPTABLE PERNOTEONDRAWING-ACCEPTABLE. | |||
38 | |||
R.E.GINNANUCLEARPOWERPLANT/ | R.E.GINNANUCLEARPOWERPLANT/Znservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial BerviceDate~cul19706.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONTC14~AUX~FWPUMPSDZSCH-INTERMED~BLDG,DRAWINGS: | |||
C-1FSummaryExamNumberCategItemNumberComponent NDEComponent TypeExam505060F-AF1.30RAFU-14RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:NOIDTAGONSTRUT.505080F-AF1.30RAFU-16RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3$NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
CGLS/NN633N-EG-13312-81-377H. | |||
505110F-AF1.30RAFU-19RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
C&LN-EG-13312-81-3771. | |||
505120F-AF1.30RAFU-20RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
505170F-AF1.30RAFU-25U-BOLT(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
505180F-AF1.30RAFU-26OERIGIDHANGER(NRC50%)95-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
VT-339 | |||
RE~ | RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6.Commercial ServiceDate~Jul19706.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.C14.-AUX.FWPUMPSDISCH-ZNTERMED. | |||
BLDG.(Cont.)SummaryExamNumberCateg505190F-AItemNumberComponent F1.30RAFU-27RIGIDRESTRAINT Component TypeOENDEExamVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-121. | |||
VT-3sNORECORDABLE INDICATIONS 6ZNSZGNZFZCANTf FILLETWELDSTOEXISTING12WF53ARE5/16"-ACCEPTABLE. | |||
505200F-AF1.30RAFU-28OERIGIDHANGER(NRC50%)95-VT-3:OWNERELECTEDEXAMREJ:PIPESUPPORTHASAPPROXIMATELY 1/2"PLAY6ISFREETOMOYENNOTSERVICEINDUCED.NCR94-121 GENERATED. | |||
VT-3:RE-EXAMfNORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
VT-3VT-3505210F-AF1.30RAFU-29GUIDE(NRC50%)OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-121 VT-3:NORECORDABLE INDICATIONS 6ZNSZGNZFZCANTf 1/4"FILLETWELDSWERE>1/4<5/1663/16FILLETWELDSWERE>3/16<1/45/16"FILLETWELDSWERE>5/16"<3/8"-ACCEPTABLE 505230D-BD2.20AFU-100(ZA)INTEGRALATTACHMENT 95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE VT-3505235F-AF1.30RAFU-100GUIDE(ZA)OEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE OTHER:ALLSHIMSNOTEDAREINADDITIONTODRAWINGS. | |||
THE7/8"SHZMSHAVE'/16"FILLERWELDSANDTHE1/4"SHIMHASA1/8"FILLETWELDSHIMSPECIFICATIONS AREUNKNOWN.40 | |||
RaE~ | RaE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
RE~ | : Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~sC14.AUX.FWPUMPSDISCH-INTERMED. | ||
BLDG.(Cont.)SummaryExamNumberCateg505360F-AItemNumberComponent F1.30RAFU-38GUIDE(NRC50%)Component TypeOENDEExamVT-395-VT-3NORECORDABLE INDICATIONS 6INSIGNIFICANTS SHIMUSEDONBOTTOMOFPIPE6ISWELDEDTOITEMP2-ACCEPTABLE 505370F-AF1.30RAFU-39GUIDE(NRC50%)OEVT-3BDS95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
410F-AF1.30RAFU-43RIGIDRESTRAINT (NRC50%)95-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
CGLS/N633,N-EG-13312-81-377J. | |||
VT-3505520F-AF1.30RAFU-54RIGIDRESTRAINT (NRC50't)OEVT-395-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
S/NN6336N-EG-13312-81-348-33. | |||
505560F-AF1.30RAFU-106GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
505580D-BD2.40AFU-108(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE ReEeGINNANUCLEARPOWERPLANTInservtce Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY14593.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197C6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~C14.AUX.FWPUMPSDISCH-INTERMED. | |||
BLDG.(Cont.)SummaryExamNumberCategItemNumberComponent Component TypeNDEExam505585F-AF1.30VAFU-108VARIABLESPRING(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
TEMP.136DEG.F,SETTING=1.45=104g'SC<YPEBSIZElfID/N-EG-13312-82-296. | |||
C15~TURBAUXFWPUMPDISCHARGE DRAWINGS: | |||
C-1eSummaryExamNumberCateg505612F-AItemNumberComponent F1.30RAFU-87GUIDE(NRC50%)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
C16~AUX'WPUMPSDISCH-INTERMED~BLDG'RAWINGS: | |||
C-1SummaryExamNumberCateg505640F-AZtemNumberComponent F1.30RAFU-64GUIDE(NRC50't)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:DISTANCEBETWEENPIPE&GUIDE-NORTHSIDE=0"fSOUTH,EAST&WEST<1/16"&NOT0".505680F-AF1.30RAFU-68RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
C&LS/N6339N-EG-13312-91-348-40. | |||
42 RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~tC16.AUX.FWPUMPSDISCH>>INTERMED. | |||
BLDG.(Cont.)Summary.ExamNumberCategItemNumberComponent Component TypeExam505690F-AF1.30RAFU-69GUIDE(NRC50t)OE95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:DISTANCEBETWEENPIPE&GUIDEISASFOLLOWSNORTHSIDE1/8",SOUTHSIDE=OmsEAST6WESTSIDES=1/16".505710F-AF1.30RAFU-71OERIGIDRESTRAINT (NRC50%)~95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
VT-3505760F-AF1.30VAFU-76VARIABLESPRING(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
TEMP.84DEG.F.,SETTING0.85=2451'S.IDNEG1331282306B,TYPEB.505840D-BD2.20AFU-93(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
505845F-AF1.30RAFU-93GUIDE(IA)OEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
OTHER:ALLSHIMSNOTEDAREINADDITIONTODRAWINGS, THE7/8"SHIMSHAVE3/16"FILLETWELDSANDTHE1/4"SHIMHASA1/8"FILLETWELD.SHIMSPECIFICATIONS AREUNKNOWN. | |||
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~sC16.AUX.FWPUMPSDISCH-INTERMED. | |||
BLDG.(Cont.)SummaryNumber505940ExamItemCategNumberComponent F-AF1.30RAFU-85GUIDE(NRC50%)NDEComponent TypeExamOEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE NOTE:LIMITATION, GROUTCONCEALING PARTOFCOLUMNTOBEAMWELD506040F-AF1.30RAFU-120RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
S/NN663.IDPN-EG-13312-81-345-8. | |||
C17~STANDBYAUXFWFRMPEN119AUXFWPUMPCDRAWINGS: | |||
C-21SummaryExamNumberCategItemNumberComponent Component TypeNDEExam507240F-AF1.30RAFU-261(AFW-74)OEU-BOLT(NRC50%)VT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
507250F-AF1.30RAFU-262(AFW-75)U-BOLT(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
507290F-AF1.30RAFU-266(AFW-79)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
507350F-AF1.30RAFU-272(AFW-85)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
ReE~ | ReE~GINNANUCLEARPOWERPLANTInservice Znspection Report1990-1999 | ||
ReE. | : Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DB.National BoardNumberforUnitN~AATTACHMENT ICLASS3COMPONENTS CONT~C17.STANDBYAUXFWFRMPEN119-AUXFWPUMPC(Cont.)SummaryExamNumberCateg507390F-AItemNumberComponent F1.30RAFU-164(AFW-89)GUIDE(NRC50%,)OEVT-3NDEComponent TypeExam95-VT-3!NORECORDABLE INDICATIONS | ||
ReE. | -ACCEPTABLE. | ||
507445F-AF1.30RAFU-153(AFW-120) | |||
GUIDE(NRC50%)OEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 507500F-AF1.30RAFU-159(AFW-98)GUIDE(NRC50%)OEVT-395-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:SHIMPLATEBETWEENITEMgl6ZTEMf2ZSTACKED.507520F-AF1.30RAFU-158(AFW-100) | |||
GUIDE(NRC50%)OEVT-395-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
507560F-AF1.30RAFU-196(AFW-104) | |||
GUIDE(NRC50t)OEVT-395-VT-3$NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
45 ReE~GZNNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfRec[.)~NAS.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONTtC18.STANDBYAUXFWFRMPEN123-AUXFWPUMPDDRAWINGS'-25 SummaryNumberExamCateg508145F-AZtemNumberComponent F1.30RAFU-231(AFW-51)GUIDE(IA)NDEComponent TypeExamVT-3OE95-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE BASELINEEXAMPERFORMED AFTERRE-INSTALLATION OFSUPPORT,NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:DAMAGEIDENTIFIED ONPIPEADJACENTSUPPORTSNCR95025GENERATEDS AREACONDITIONED, SEEPACKAGE.508146D-BD2.20AFU-231(AFW-51)(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
508147F-AF1.30RAFU-232(NEW)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
INSIG:NOSHIMITEMS4-ACCEPTABLE. | |||
508150F-AF1.30RAFU-234(NEW)U-BOLT(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
CGLIDN-EG-13312-81-377N. | |||
508170F-AF1.30RAFU-237(AFW-55)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
508260.F-AF1.30RAFU-246(AFW-64)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCerti.ficate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.tC18.STANDBYAUXFWFRMPEN123-AUXFWPUMPD(Cont.)SummaryExamNumberCateg508330F-AItemNumberComponent Fl30RAFU-253(AFW-71)RIGIDHANGER(NRC50't)OEVT-3NDEComponent TypeExam95-VT-3sNORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
508360F-AF1.30RAFU-179(AFW-119) | |||
GUIDE(NRC50'4)OEVT-395-VT-3sNORECORDABLE INDICATIONS | |||
-ACCEPTABLE OTHER:NOTETOLERANCES BETWEENPIPEANDSUPPORT[SETTINGS PERDRAWINGIN()]NORTH0(1/8)6EAST1/8(1/16)6SOUTH3/16(0)6WEST0(1/32)~508390F-AF1.30RAFU-182(AFW-112) | |||
GUIDE(NRC50IL)OE95-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE OTHER:NOTE,NOSHIMPLATEITEMg9.508435F-AF1.30RAFU-187(AFW-121) | |||
GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 508450F-AF1.30RAFU-189('AFW-106) | |||
GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE OTHER:NOTE,ITEMf7SHIMPLATEHASFULLLENGTHFILLETWELD,NOTTACKWELD.47 0 | |||
ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)'%~A B.commercial ServiceDate~Jul197D6.National BoardNumtecforUnitjNAATTACHMENT ICLASS3COMPONENTS CONTsC19~TURBINEDRIVENAUX~FWPUMPSUCTIONDRAWINGS: | |||
C-16SummaryExamNumberCategItemNumberComponent Component TypeNDEExam508500F-AF1.30RAFU-1OERIGIDRESTRAINT (NRC50%)VT-395-VT-3!NORECORDABLE INDICATIONS | |||
&INSIGNIFICANTf PAINTISSTARTINGTOBLISTERDUETOLIGHTCORROSION ONITEMSP4&PS-ACCEPTABLE C&LID'SN-EG-13312-82-311-I, N-EG-13312-82-311-J. | |||
508510F-AF1.30RAFU-2OERIGIDRESTRAINT (NRC50t)95-VT-3:NORECORDABLE INDICATIONS | |||
&OTHERf4"LINEHAS2WELDEDLUGSAT0&180DEG.TORIGIDRESTRAINT. | |||
S/NN633,N-EG-13312-81-348-2 | |||
-ACCEPTABLE. | |||
VT-3C20.SWSUPPLYTOSAFWPUMPCDRAWINGS! | |||
C-28SummaryExamNumberCategItemNumberComponent Component TypeNDEExam508815D-BD2.20SWU-590(SW-122)(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
508817F-AF1.30RSWU-590(SW-122)GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
R.E. | R.E.GINNANUCLEARPOWERPLANTaInservice Inspection Report1990-1999 | ||
ReE~ | : Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul199DB.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.tC21~MOTORDRIVENAUX,FWPUMPSUCTIONDRAWINGS: | ||
C-33SummaryExamNumberCateg508600F-AItemNumberF1.30RComponent SWU-284RIGIDRESTRAINT 50%)Component TypeExamOEVT-3(NRC95-VT-3!NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
NOTE:CGLfN-EG-13312-81-178B, NOSIZELABELED'22. | |||
SWSUPPLYTOSAFWPUMPDDRAWINGS: | |||
C-28SummaryExamNumberCateg508930D-BItemNumberD2.20Component SWU-514(SW-142)(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
508933F-AF1.30RSWU-514(SW-142)GUIDE(IA)ASMEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
OTHERITEMP2ANGLEISINCONTACTWITHCONDUITATWALL.USE-AS-IS PERENGINEERING. | |||
C23~STANDBYAUX.FW,SWSUPPLYTOSAFWPUMPDDRAWINGS: | |||
C-28SummaryNumberExamCateg508960F-AItemNumberComponent F1.30RSWU-522(SW-140)GUIDEComponent TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPer'iod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6C.ommercial ServiceDate~Jul197CS.National BoardNumberforUnit~NAATTACHMENT I.CLASS3COMPONENTS CONT.tC24~MAINSTEAMSUPPLYTOAUXFWPUMPTURBINEDRAWINGS'-32 SummaryExamNumberCateg509020D-BItemNumberD2.20Component Component TypeMSU-64(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3!NORECORDABLES INSIGNIFICANT 6OTHERSTOPLUGBENT5DEG'.f3/16"CLEARANCE, SOUTHLUG1.8"CLEARANCE. | |||
BOTTOMTIGHTTOg7fNORTHTIGHTTOg5.DCRGENERATED TOUPDATEDRAWINGFOR2ADDITIONAL LUGS-ACCEPTABLE 509025F-AF1.30RMSU-64RIGIDRESTRAINT (IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE C25.MAINSTEAMLOOPATOAUXFWPUMPTURBINEDRAWINGS: | |||
C-32SummaryNumberExamCategItemNumberComponent Component TypeNDEExam509160D-BD2.30MSU-78(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:TEMP.76DEG.'F.;SETTING31/8".NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
509165F-AF1.308MSU-78MECHANICAL SNUBBER(IA)OEVT-395-VT-3:TEMP.76DEG.F.fSETTING31/8",NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
50 | |||
ReE. | ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report,1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Ju11970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.!C26eAUXFWPUMPAFLOWCONTROLBYPASSDRAWINGS: | |||
C-1GSummaryExamNumberCateg510035D-BItemNumberComponent Component TypeD2.20AFU-60(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
510040F-AF1.30RAFU-60GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
C27.AUXFWPUMPBFLOWCONTROLBYPASSDRAWINGS: | |||
C-1HSummaryExamNumberCateg510065D-BItemNumberComponent D2.20AFU-128(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
510070F-AF1.30RAFU-128GUIDE(IA)OEVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
51 | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6~Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NBATTACHMENT ID.HIGHENERGYCOMPONENTS tDl>>MAINSTEAMLOOPAOUTSIDECVDRAWINGStB-9ASummaryExamNumberCategItemNumberComponent Component TypeExam200020HE-DBLlREDUCER-TO-TEE AUGVT-1MTRT95-VT-1&MT:NORECORDABLE INDICATIONS. | |||
RT:NORECORDABLE | |||
&INSIGNIFICANTS POROSITY&SLAG.NOAPPARENTCHANGESINCELASTEXAMINATION | |||
-ACCEPTABLE D2~MAINSTEAMOUTSIDECVDRAWINGS: | |||
HE-7tSummaryNumberExamCategItemNumberComponent Component TypeNDEExam200025HE-DBL2TEE-TO-PIPE AUGVT-1MTRT95-VT-1&MT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE-RT-NORECORDABLE | |||
&INSIGNIFICANTS SLAGSPOROSITYS WASHOUTSNOCHANGESINCELASTEXAMINATION | |||
-ACCEPTABLE D3~MAINSTEAMLOOPBOUTSIDECVDRAWINGS: | |||
B-10SummaryExamNumberCategItemNumberComponent Component TypeExam200045HE-DBPlREDUCER-TO-TEE AUGVT-1RTMT95-MT:NORECORDABLE, LIM:L=23"-35" DUETOSUPPORT90t.VT-1:NORECORDABLE | |||
&INSIGNIFICANT L=561/2",W=ll1/2"UP,2INDICATIONS FROMLINEUPLUG-1/8X21/2X1/64.RT:NORECORDABLE | |||
&INSIGSPOROSITYS PEENMARKSSWASHOUTSNOCHANGE-ACCEPTABLE. | |||
a52 R.E.GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999 | |||
: Interval, S'econdPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IHIGHENERGYCOMPONENTS CONTD4,FEEDWATER TURBINEBUILDINGDRAWINGS: | |||
HE-6SummaryNumberExamCategItemNumberComponent Component TypeNDEExam200050HE-DBM3PIPE-TO-TEE AUGVT-1UTMT95-VT-1&MT:NORECORDABLE INDICATIONS. | |||
UT:NORECORDABLE | |||
&GEOMETRYS COUNTERBORE, CROWN&ROOTGEOMETRY. | |||
ZERODEGREESCANPERFORMED IN'92.,>90%COVERAGE-ACCEPTABLE. | |||
D5~FEEDWATER LOOPAOUTSIDECVDRAWINGSHE-5SummaryExamNumberCategItemNumberComponent Component TypeExam200055HE-DBM4TEE-TO-REDUCER AUGVT-1~UTMT95-VT-1&MT;NORECORDABLE INDICATIONS. | |||
UTNORECORDABLE | |||
&GEOMETRYS COUNTERBORE | |||
&ROOTGEOMETRY, | |||
>90'tCOVERAGEACCEPTABLE.'6. | |||
FEEDWATER LOOPBOUTSIDECVDRAWINGS'E-5 SummaryExamNumberCateg200075HE-DBItemNumberComponent AlTEE-TO-REDUCER Component TypeAUGNDEExamVT-1UTMT95-VT-1&MT:NORECORDABLE INDICATIONS. | |||
UTsNORECORDABLE, INSIGNIFICANT | |||
&GEOMETRYS COUNTERBORE | |||
&SLAGINCLUSION, 90'tCOVERAGEACHIEVED-ACCEPTABLE. | |||
53 RaE~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IHIGHENERGYCOMPONENTS CONTD7eMAINSTEAMLOOPAOUTSIDECVDRAWINGS: | |||
B-9ASummaryExamNumberCategItemNumberComponent NDEComponent TypeExam200160HE-CBL3519VALVE-TO-REDUCER AUGVT-1RTMT95-VT-1&MT:NORECORDABLE INDICATIONS. | |||
RT:NORECORDABLES" INSIGNIFICANT | |||
&OTHERGOUGEINBASEMETALAT71"fPOROSITYNOCHANGESINCELASTEXAM-ACCEPTABLE. | |||
D8~MAINSTEAMLOOPBOUTSIDECVDRAWINGS: | |||
B-10SummaryExamItemNumberCategNumberComponent NDEComponent Type~Exam200220HE-CBP3518VALVE-TO-REDUCER AUGVT-1RTMT95-MT:NORECORDABLE INDICATIONS. | |||
VT-1:NORECORDABLE | |||
&INSIGNIFICANTS LINE-UPLUG.RT:NORECORDABLE | |||
&6INSIGNIFICANT; | |||
: POROSITY, SLAG,BASEMETALINDICATION WHERETEMPORARY ATTACHMENT LOCATED944".NOCHANGESINCELASTEXAM-ACCEPTABLE. | |||
D9~MAINSTEAMTURBINEBUILDINGDRAWINGS: | |||
HE-7ASummaryExamNumberCategItemNumberComponent NDEComponent TypeExam200280HE-CBClELBOW-TO-PIPE AUGVT-1UTMT95-MT:NORECORDABLE. | |||
VT-1:INSZGNIFZCANT; MINORPITTZNGONPIPE<1/32~UTNORECORDABLE | |||
&GEOMETRYs ROOTSCOUNTERBORE, WELDCROWNGEOMETRY/REDIRECTED BEAM.>90%COVERAGEOBTAINED-ACCEPTABLE. | |||
54 IO R.E.GINNANUCLEARPOWERPLANTInservice Inspection. | |||
Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IHIGHENERGYCOMPONENTS CONT.D9.MAINSTEAMTURBINEBUILDING(Cont.)SummaryExamNumberCateg200285HE-CBItemNumberComponent DPIPE-TO-ELBOW Component TypeAUGNDEExamVT-1UTMT95-MT:NORECORDABLE. | |||
VT-1:INSIGNIFICANT MINORPITTING1/32ONPIPE~UTNORECORDABLE 9GEOMETRY6OTHERSROOTSCOUNTERBORE 9WELDCROWN5MODECONVERSION56SLAGINCLUSION | |||
~90%COVERAGE-ACCEPTABLE. | |||
200320HE-CBM2ELBOW-TO-PIPE D10.FEEDWATER TURBINEBUILDINGSummaryExamItemNumberCategNumberComponent DRAWINGS: | |||
HE-6AUGNDEComponent TypeExamVT-1UTMT95-VT-16MT:,NORECORDABLE INDICATIONS. | |||
UT:NORECORDABLES GEOMETRY6OTHERS'ROWN 6(ROOTGEOMETRY, COUNTERBORE 6MODECONVERSION | |||
-COUNTERBORE, | |||
)90'tCOVERAGEACHIEVEDACCEPTABLE. | |||
DllaFEEDWATER LOOPAOUTSIDECVDRAWINGS: | |||
B-11SummaryExamItemNumberCategNumber200455HE-CBComponent Z3PIPE-TO-ELBOW Component TypeAUGNDEExamVT-1RTMT95-VT-1,MT6RT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
55 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89Eastve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul197CS.National BoardNumberforUnit~NA.ATTACHMENT IHIGHENERGYCOMPONENTS CONT.tDll.FEEDWATER LOOPAOUTSIDECV(Cont.)SummaryExamNumberCateg200460HE-CBItemNumberComponent Z4ELBOW-TO-PIPE Component TypeAUGNDEExamVT-1UTMT95-VT-16MT:NORECORDABLE INDICATIONS. | |||
UTsNORECORDABLE GEOMETRY: | |||
ROOT,COUNTERBORE, ROUGHROOT,SPOTINDICATION ATWELDCROWN,)90'tCOVERAGE-ACCEPTABLE NumberCategNumber200575HE-CBComponent OlELBOW-TO-PIPE D12.FEEDWATER LOOPBOUTSIDECVSummaryExamItemComponent TypeAUGDRAWINGS: | |||
B-14NDEExamVT-1RTMT95-VT-l,MT6fRT:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
200580HE-CB----PPIPE-TO-ELBOW AUGVT-1RTMT95-MT:NORECORDABLE INDICATIONS. | |||
VT-1NORECORDABLE 6fZNSZGNZFZCANTS MINORCORROSION. | |||
RT:NORECORDABLE 6ZNSZGNZFZCANTS POROSITY&SLAG,NOAPPARENTCHANGESINCELASTEXAMINATION | |||
-ACCEPTABLE. | |||
56 | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6Co.mmercial ServiceDate~Jul197CS.National BoardNumberforUnitN~AATTACHMENT IHIGHENERGYCOMPONENTS CONT~D13~MAINSTEAMTURBINEBUILDINGDRAWINGS: | |||
HE-7ASummaryExamNumberCategItemNumberComponent Component TypeNDEExam201420HE-CS*F1.20VMS-45(S21)VARIABLESPRINGOEVT-395-VT-3:TEMP.68DEG.F.,SETTING1/2"=4825if'SsNORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
: BASELINE, REMOVEDFORACCESSOFHEWELDC1.201440HE-CS*F1.20VMS-46(S22)VARIABLESPRING(IA)OEVT-395VT3TEMP~71DEG~F~sSETTING1/2fVS2SIZE176NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
: BASELINE, REMOVEFORACCESSOFHEWELDD.201441HE-IA*C3.20MS-46(S22)(ZA)INTEGRALATTACHMENT OEMT95-MT:NORECORDABLE INDICATIONS INLIMITEDEXAM.71/2"OFWELDINBETWEENZA(BOTHSIDE)NOTACCESSIBLE FORMTVISUALPERFORMED APPROX90%INSPECTED | |||
-ACCEPTABLE. | |||
D14.FEEDWATER LOOPBOUTSIDECVDRAWINGSe B-14SummaryExamNumberCateg201860HE-CSItemNumberComponent | |||
*F1.20SFWU-38MECHANICAL SNUBBERComponent TypeOENDEExamVT-395-VT-3:BASELINEEXAMAFTERRE-INSTALLATION TEMP.68DEG.F.fSETTING31/2".NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
57 ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DB.National BoardNumberforUnit~NAATTACHMENT IE.LEAKAGETESTINGE1~LEAKAGEEXAMINATIONS CLASS1f2f3SummaryExamNumberCateg411000B-PItemNumberComponent IWB5221PT-7LEAKAGETESTOFREACTORCOOLANTSYSTEMASMEVT-2NDEComponent TypeExam95-VT-2:TESTSATISFACTORYf DEFICIENCIES CORRECTED DURINGTESTgSEEEXAMSHEETFORDETAILS-ACCEPTABLE. | |||
411400HE-LK---MSHIGHENERGYAUG95-VT-2:NORECORDABLE INDICATIONS, ACCEPTABLE. | |||
t411600C-HIWC5221FWOUTSIDECONTAINMENT ASME95-VT-2:NORECORDABLE INDICATIONS | |||
-TESTACCEPTABLE. | |||
VT-2411700D-BIWD5221AUXFW"A"PUMPASMEVT-295-VT-2:NORECORDABLE INDICATIONS, ACCEPTABLE. | |||
412100D-BIWD5221STANDBYAUXILIARY FEEDWATER PUMP"D"ASMEVT-295-VT-29NORECORDABLE | |||
&INSIGNIFICANT PACKINGLEAKONV9708B&V9704B.GASKETLEAKBETWEENV9714B&V9715B.COMPLETETESTPERFORMED IN2PARTS-TESTSATISFACTORY. | |||
412500C-HIWC5221SAFETYINJECTION "A"ASMEPUMPIN/OUTCONTAINMENT VT-295-VT-2:NORECORDABLE | |||
&OTHER)BORICACIDRESIDUEONVALVES828A,828B&12400.PACKING/STEM DRY.FLANGEATFE-294ATINTERFACE, RANDOM360DEGREES-TOBEDECONNED&CHECKEDONPT-8.8.TESTSATISFACTORY. | |||
58 R.E.GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ILEAKAGETESTING.CONT.El.LEAKAGEEXAMINATIONS CLASS1,2,3(Cont.)SummaryExamNumberCateg413000C-HItemNumberComponent IWC5221CONTAINMENT SPRAYAPUMPDISCHARGE Component TypeASMENDEExamVT-295-VT-2:NORECORDABLE 6INSIGNIFICANTs DRIEDBORICACIDONV831AsV857BsV857CSV893A&V893B~PACKINGLEAK6DRYBORICACIDRESIDUEONV862A.BODYTOBONNETHASBORICACIDRESIDUEATBOTTOMOFJOINT.ACCEPTABLE. | |||
413100C-HIWC5221CONTAINMENT SPRAYBPUMPDISCHARGE ASMEVT-295-VT-2:NORECORDABLE 6INSIGNZFICANT PACKINGLEAKBORICACIDRESIDUEONV860C6V869A.SWAGE-LOK TEEUPSTREAMOFLT-921HASBORICACIDRESIDUE.ACCEPTABLE. | |||
413150C-HIWC5221SPRAYADDITIVENOAHTANKASMEVT-295-VT-2:NORECORDABLE INDICATIONS, ACCEPTABLE 413600D-BIWD5221AUXCOOLINGINSIDEASMECONTAINMENT VT-295-VT-2:NORECORDABLE 6INSIGNIFICANT V754BHASPACKINGDRYRESIDUE.ACCEPTABLE. | |||
413700D-BIWD5221AUXCOOLINGOUTSIDEASMECONTAINMENT VT-295-VT-2:-TESTSATISFACTORY, SEEEXAMSHEETFORDETAILS.NOTE:WASTEEVAPORATOR | |||
: ISOLATED, NOTBEINGUSED.ACCEPTABLE. | |||
59 eR.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ILEAKAGETESTINGCONT~tEl.LEAKAGEEXAMINATIONS CLASS1,2,3(Cont.)SummaryExamNumberCateg414000D-AItemNumberComponent IWD5221SERVICEWATEROUTSIDECONTAINMENT Component TypeASMENDEExamVT-295-VT-2NORECORDABLE 6INSIGNIFICANT "A"LOOPBURIEDPIPEEXAMINEDUSINGIDPIPECRAWLER.IDGOODCONDITION-NO LEAKPATHSOBSERVED. | |||
REMOVEDRUSTONPACKINGGLANDONV4627.AEcDSWPUMPBOUNDARIES PERFORMED | |||
-ACCEPT.PARTIALEXAM.414100D-AIWD5221SERVICEWATERTOAUXFWPUMP"A"ASMEVT-295-VT-2tNORECORDABLE INDZCATIONS. | |||
ACCEPTABLE. | |||
414600C-HIWC5221CHARGING6SEALWATERASMEFROMPUMPS(IN/OUTCV)95-VT-2tNORECORDABLE 6INSIGNIFICANTS'ERFORMED DURINGPT7~PACKINGGLANDBORONRESIDUEV281ASV2875V277ASV291V288.BODY-BORON RESIDUEPIC-1836BODYTOBONNETONV357".PACKZNGLEAKONV392B,FIXEDDURINGTEST.ALLDECONNED-WILL BERECHECKED. | |||
VT-2415500D-BIWD5221SPENTFUELPOOLCOOLING-A ASMEVT-295-VT-2tNORECORDABLE | |||
&INSIGNIFICANTS CHECKVALVEV8655HASBODYTOBONNETLEAKWITHBORICACIDRESIDUE.VT-3ONBOLTINGWHENVALVEIDOPENED,WORKREQUESTWRITTENACCEPTABLE 415550D-BIWD5221SPENTFUELPOOLCOOLING-B ASMEVT-295-VT-2tNORECORDABLE 6INSIGNIFICANTS FULLEXAMINATION BOUNDARYHASBEENCOMPLETED, TESTSATISFACTORY. | |||
SEEEXAMINATION RECORDFORDETAILS.60 ReEGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul1979S.National BoardNumberforUnit~NAATTACHMENT IF~SNUBBERPROGRAMCOMPONENTS gFluSTEAMGENERATOR BDRAWINGS: | |||
A-7FSummaryExamNumberCateg600120SN-VTItemNumberComponent SGB-3HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395VT3NORECORDABLE INDICATIONS5TEMP67DEGF5SETTING393/8",S/NAH-2-ACCEPTABLE. | |||
600121SN-FTSGB-3HYDRAULIC SNUBBERAUGFT9P-FT-OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOg19404251. | |||
F2~AUX~FWPUMPSDISCH-INTERMED~BLDG~DRAWINGS: | |||
C-1ESummaryExamNumberCateg600240SN-VTZtemNumberComponent Component TypeAFU-34AUGMECHANICAL SNUBBERNDEExamVT-395-VT-3:TEMP.70DEG.F.,SETTING27/8",S/N14448.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
600241SN-FTAFU-34MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
SNUBBERDEGRADEDANDREPLACED. | |||
WOP19404236. | |||
600280SN-VTAFU-75MECHANICAL SNUBBERAUGVT-395-VT-3:TEMP.73DEG.F.,SETTING21/8",S/N20924.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 61 RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)a1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F2~AUX.FWPUMPSDISCH-INTERMED. | |||
BLDG.(Cont.)SummaryExamNumberCateg600281SN-FTItemNumberComponent AFU-75MECHANICAL SNUBBERNDEComponent TypeExamAUGFT95-FT!OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOP19404237. | |||
600400SN-VTAFU-123MECHANICAL SNUBBERAUGVT-3095VT3TEMP~73DEG~F5SETTING25S/N22485~NORECORDABLE | |||
&INSIGNIFICANTS SNUBBERHASMOVEMENTINBOTHDIRECTIONS | |||
-ACCEPTABLE. | |||
600401SN-FTAFU-123MECHANICAL SNUBBERAUGFT95-FT!OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
SNUBBERDEGRADEDANDREPLACEDWOg19404238. | |||
F3~STEAMGENERATOR BBLOWDOWNLINEDRAWINGS: | |||
B-31SummaryExamNumberCategItemNumberComponent Component TypeNDEExam600460SN-VTBDU-16AUGMECHANICAL SNUBBERVT-395-VT-3!BASELINEEXAMAFTERREINSTALLATION DUETOBLOWDOWNREPLACEMENT. | |||
TEMP.68DEG.F.,SETTING27/BmsS/N10182.SNUBBERINSTALLED 180DEGREESFROMDRAWING,NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
600461SN-FTBDU-16MECHANICAL SNUBBERAUGFT95-FT!OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WON19404239. | |||
62 | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTZnservice Inspects.on Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONTF4.2"CVCSRELIEFLINETOPRTDRAWINGSa B-32SummaryExamNumberCateg600940SN-VTItemNumberComponent CVU-80MECHANICAL SNUBBERAUGVT-3.Component. | |||
TypeExam95VT3TEMP~74DEG~F9SETTING11/2fS/N235189NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 600941SN-FTCVU-80MECHANICAL SNUBBERAUGFT95-FT:OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
REPLACEDSNUBBER-DEGRADED, WOP19404240. | |||
F5~CVCSLETDOWNLINETOMZXBEDDEMZNDRAWINGS: | |||
B-36SummaryExamNumberCateg601080SN-VTItemNumberComponent CVU-372MECHANICAL SNUBBERAUGVT-3NDEComponent TypeExam95VT3TEMP~f69DEGFfSETTING3/49S/N9478~NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601081SN-FTCVU-372MECHANICAL SNUBBERAUGFT95-FT:OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
SNUBBERDEGRADEDANDREPLACED, WOÃ1940424163 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT.F6.FEEDWATER LOOPAINSIDECVDRAWINGS'-12 SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam601110SN-VT---FWU-5AUGVT-3HYDRAULIC SNUBBER95-VT-3:TEMP~69DEG~F~6SETTING1/2EXT3fS/N2500-10-152. | |||
NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601111SN-FTFWU-5HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOP19404249. | |||
F7.FEEDWATER LOOPBOUTSIDECVDRAWINGS'-14 SummaryExamNumberCategItemNumberComponent Component TypeNDEExam601270SN-VTFWU-44AUGHYDRAULIC SNUBBERVT-395-VT-3:BASELINEEXAMAFTERREINSTALLATION. | |||
TEMP.72DEGF.,S/NG43864-02-20, SETTING315/16meSPECIFICATION STATES3".NCR95-045 GENERATED, NOTSERVICEINDUCED.DISPOSITIONED USE-AS-IS PERENGINEERING. | |||
NORECORDABLE, OTHER6REJECT-ACCEPTABLE. | |||
601271SN-FTFWU-44HYDRAULIC SNUBBERAUGFT95-FT!OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOI.19404250. | |||
R.E. | R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriodfThirdOutage(1995)1.OwnerRochester Gas67ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial ServiceDate~cul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT.FS~MAINSTEAMLOOPBOUTSIDECVDRAWINGS: | |||
B-10ASummaryExamNumberCateg601390SN-VTItemNumberComponent MSU-12MECHANICAL SNUBBERAUGVT-3NDE'Component TypeExam95-VT-3sTEMP59DEG.F,SETTING31/4",S/N9400.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601391SN-FTMSU-12MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOE19404244. | |||
601429SN-VT----MSU-18(NORTH)MECHANICAL SNUBBERAUGVT-395-VT-3:TEMP59DEGF.,SETTING21/4",S/N7478.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601430SN-VT----MSU-18(SOUTH)MECHANICAL SNUBBERAUGVT-395VT3TEMP~59DEG~FfSETTING21/45S/N7197~NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601431SN-FTMSU-18(NORTH)MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOP19404246. | |||
601432SN-FT----MSU-18(SOUTH)MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBERFAILED.SNUBBERREPLACEDWO19404245. | |||
REQUIREDTOTESTMSU-19NORTHPERNCR95-017, WO19501218. | |||
FUNCTIONAL TESTOFSNUBBER-RETESTIN1996.65 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commeccial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~tF8.MAINSTEAMLOOPBOUTSIDECV(Cont.)SummaryExamNumberCateg601439SN-VTItemNumberComponent MSU-19(NORTH)MECHANICAL SNUBBERAUGVT-3NDEComponent TypeExam95-VT-3sBASELINEFORREINSTALLATION, FTEXPANDEDTESTTORESOLVENCR95-017 (MSU-18). | |||
TEMP.55DEG.FfSETTING3"fS/N9369.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE 601441SN-FT----MSU-19(NORTH)MECHANICAL SNUBBERAUGFT95-FT$OTHERFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFMSU-18SOUTH-ACCEPTABLE. | |||
WO195012186NCR95-017. | |||
EXPANDEDEXAM.F9MAINSTEAMLOOPAOUTSIDECVDRAWINGS: | |||
B-9SummaryNumberExamCategItemNumberComponent Component TypeNDEExam601550SN-VTMSU-44MECHANICAL SNUBBERAUGVT-395-VT-3sTEMP.76DEG.F.,SETTING31/2",S/N1468,NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601551SN-FTMSU-44MECHANICAL SNUBBERAUGFT95-FTsOTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOP19404243. | |||
066 R.E,GINNANUCLEARPOWERPLANTInservice Znspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1976S.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F10eMAINSTEAMLOOPBATMOSPHERIC VENTDRAWINGS: | |||
B-10SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam601570SN-VTMSU-57MECHANICAL SNUBBERAUGVT-395VT3TEMP74DEGFsSETTING31/4sS/N27182'ORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601571SN-FTMSU-57MECHANICAL SNUBBERAUGFT95-FT:OTHERNTESTFAILED,SNUBBERREPLACEDUNDERWO¹'9404247. | |||
REQUIREDTOTESTMSU-60PERNCR95-039, WO¹19501414. | |||
FUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
RETESTIN1996.Fll~MAINSTEAMLOOPAATMOSPHERIC VENTDRAWINGS: | |||
B-9ASummaryExamNumberCateg601590SN-VTItemNumberComponent MSU-60MECHANICAL SNUBBERAUGVT-3NDEComponent TypeExam95VT3BASELINEEXAMDUETOFTTESTINGEXPANSION fTEMP~72DEG.FesSETTING35/8",PSA-3,5"STROKE.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601591SN-FTMSU-60MECHANICAL SNUBBERAUGFT95-FT:OTHERFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFMSU-S7,EXPANDEDEXAM.WO19501414EcNCR95-039. | |||
ACCEPTABLE. | |||
67 eR.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5C.ommercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT.F12.MAINSTEAMLOOPATOAUXFWPUMPTURBINEDRAWINGS: | |||
C-32SummaryExamNumberCateg601630SN-VTItemNumberComponent Component TypeMSU-78AUGMECHANICAL SNUBBERNDEExamVT-395VT3TEMP~76DEG~F5SETTING31/85S/N85765PSA-10,6"STROKE.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE-601631SN-FTMSU-78MECHANICAL SNUBBERAUGFT95-FT:OTHER(FUNCTIONAL TESTOFSNUBBER-ACCEPTABLE. | |||
WOP19404242. | |||
F13.STANDBYAUXFWTHRUPEN123TOBS/GFWHDINCVDRAWINGS: | |||
C-24SummaryNumberExamCategItemNumberComponent NDEComponent TypeExam601940SN-VTAFU-208(AFW-13)HYDRAULIC SNUBBERAUGVT-395-VT-3:TEMP.63DEG.F.,SETTING2",S/N12907.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601941SN-FT----AFU-208(AFW-13)HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER5'AILED,REPLACEDSNUBBERWOI19404248. | |||
NCR95-044 REQUIREDEXPANSION TOAFU-229,N-616&PS-6.RETESTIN.'96-ACCEPTABLE. | |||
68 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONTtF149STANDBYAUXFWTHRUPEN119TOAS/GFWHDINCVDRAWINGSt C-20SummaryExamNumberCateg601970SN-VTItemNumberComponent AFU-224(AFW-28)HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395-VT-3:BASELINEEXAMDUETOFTTESTINGEXPANSION. | |||
TEMP.68DEG~FfSETTING21/2fFLUIDLEVEL75'tfS/N12905'ORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601971SN-FTAFU-224(AFW-28)HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-229-EXPANDED EXAMFAILED.WOI19501481NCR95-047. | |||
REPLACEDSNUBBER.REQUIREDTOTESTAFU-226PERNCR95-049 6WOg19501483. | |||
RETESTIN1996.601980SN-VTAFU-226(AFW-27)HYDRAULIC SNUBBERAUGVT-395-VT-3$BASELINEEXAMDUETOFTTESTINGEXPANSION TEMP.67DEG.F.,SETTING31/2",S/N12401.NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
601981SN-FTAFU-226(AFW-27)HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-224.EXPANDEDEXAM-ACCEPTABLE. | |||
WOÃ195014836NCR95-049. | |||
69 | |||
R, | R,EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial NerviceDate~Jul19706.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F15~PRESSeRELIEFFMPRESS.TORELIEFMANIFOLDDRAWINGS'-2 SummaryExamNumberCateg602080SN-VTItemNumberComponent N616HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395-VT-3:BASELINEEXAMDUETOFTTESTINGEXPANSION (NCR94034)~TEMP~58DEG~F~5SETTING25/85FLUIDLEVEL75%,NORECORDABLE | |||
&OTHERNCOTTERPINONHEAD-OK,PHR-12SUPPORTISWELDEDTOTHEWALLPLATEOFN616-NOBOLTSACCEPTABLE. | |||
AUGN616HYDRAULIC SNUBBER602081SN-FT95-FT:OTHERfFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-208,EXPANDEDEXAM-ACCEPTABLE. | |||
WOE195014466NCR95-044. | |||
FTF16.3-IN.PRESSURIZER RELIEFLINEDRAWINGS: | |||
A-12SummaryNumber602120ExamCategItemNumberComponent SN-VT---PS-6HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395-VT-3:BASELINEEXAMDUETOFTTESTINGEXPANSION TEMP.69DEGF~5SETTING35/85S/NPD877671239'EWCOTTERPININSTALLED. | |||
NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
602121SN-FTPS-6HYDRAULIC SNUBBERAUGFT95-FT:OTHERNFUNCTZONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-2085EXPANDEDEXAM-ACCEPTABLE. | |||
WOP195014476NCR95-044. | |||
70 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial ServiceDate~cul1970S.National BoardNumberforUnitjNAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F17STANDBYAUXFWTHRUPEN119TOAS/GFWHDINDRAWINGS: | |||
C-20SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam602500SN-VTAFU-229HYDRAULIC SNUBBERAUGVT-395-VT-3BASELINEEXAMDUETOFTTESTINGEXPANSION TEMP69DEG~FsSETTING21/4sFLUIDLEVEL50'tsS/N21009'ORECORDABLE INDICATIONS | |||
-ACCEPTABLE 602501SN-FTAFU-229HYDRAULIC SNUBBERAUGFT95-FT!OTHERSFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-208,EXPANDEDEXAMFAILED.WOg19501445&NCR95-044. | |||
REPLACEDSNUBBER,REQUIREDTOTESTAFU-224PERNCR95-047 | |||
&WOE19501481. | |||
RETESTIN'96.71 ReE~GINNANUCLEARPOWERPLANTkInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul197CS.National BoardNumtecforUnit~NBATTACHMENT IGSEISMICSUPPORTS'l | |||
~RCPSEALWATERRETURN-RELIEFTOPRTDRAWINGS: | |||
SS-1SummaryNumber700110ExamItemCategNumberComponent SS-CS*F1.20RCVU-125GUIDE6IAComponent TypeAUGNDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE G29RCPRESSURERELIEFMANIFOLDTOPRTDRAWINGS: | |||
SS-2SummaryExamNumberCateg700140SS-CSItemNumberComponent | |||
*F1.20RCVU-130RIGIDHANGER6IAComponent TypeAUGNDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
G3.MAINSTEAM DRAWINGS: | |||
B-9ASummaryExamNumberCateg700490SS-CSItemNumberComponent | |||
*F1.20RMSU-53RIGIDSUPPORT6IAOEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE | |||
&INSIGNIFICANTs LOOSEPARTS,HOLDDOWNBOLTSSOUTHEAST 6SOUTHWEST ARELOOSE,ACCEPTABLE PERNCR94-059.NOTSERVICEINDUCED.700510SS-CS*F1.20RMSU-47RIGIDSUPPORT6IAOEVT-395-VT-3sNORECORDABLE 6INSIGNIFICANTs JACKINGBOLTSLOOSE,LIGHTRUST.LOOSEBOLTSACCEPTABLE PERNCR94-0626NOTSERVICEINDUCED-ACCEPTABLE. | |||
72 0ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)r1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5C.ommercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISEISMICSUPPORTSCont.G3.MAINSTEAM (Cont.)SummaryExamNumberCateg700520SS-CSItemNumberComponent | |||
*F1.20RMSU-48RIGIDSUPPORT&IAComponent TypeOENDEExamVT-395-VT-3sNORECORDABLE | |||
&fINSIGNIFICANTS LOOSEJACKBOLT)LIGHTRUST.ACCEPTABLE PERNCR94-063.NOTSERVICEINDUCEDACCEPTABLE. | |||
G4~RESIDUALHEATREMOVALDRAWINGS: | |||
B-21SummaryNumber700580ExamItemCategNumberComponent SS-CS*F1.20RRHU-87RIGIDSUPPORT&IAComponent TypeOENDEExamVT-395-VT-3$NORECORDABLE INDICATIONS | |||
-ACCEPTABLE INSIGsCORROSION, LIGHTRUSTONBASEPLATE-ACCEPTABLE. | |||
700590SS-CS*F1.20RRHU-90RIGIDSUPPORT&IAOEVT-395-VT-3sNORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
INSIGsCORROSION, RUST&CHIPPEDPAINTONBASEPLATE-ACCEPTABLE. | |||
G5eSeW.TOACWATERCHILLERSDRAWINGS: | |||
C-16SummaryNumberExamCategItemNumberComponent Component TypeNDEExam700740SS-CS*F1.20VSWU-364OEVARIABLESPRING&IAVT-395-VT-3NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
TEMP.55DEG.F.,SETTING=1.05=1456if'SfN-EG-13312-82-308 TYPEBfSIZE10~NOTEsPLATEg3TOBEAM(WSX35)WELDISWELDEDALLAROUND~73 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriodsThirdOutage(1995)I1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISEISMICSUPPORTSCont.G6.STANDBYAUXFEEDWATER DRAWINGS: | |||
C-28ASummaryExamNumberCateg700790SS-CSItemNumberComponent | |||
*F1.20RSWU-525U-BOLTComponent TypeAUGNDEExamVT-395-VT-3:NORECORDABLE INDICATIONS | |||
-ACCEPTABLE. | |||
74 | |||
0R.E. | 0R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IH~STEAMGENERATOR EDDYClJRRENTEXAMINATIONS-Hl~STEAMGENERATOR ASummaryExamNumberCateg800000B-QItemNumberB16.20Component OPENGENERATOR TUBESPREV.IDENT.DEGRAD20Component TypeASMENDEExamETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.800150B-QB16.20OPENGENERATOR TUBESASME20'%OTATING RANDOMSAMPLEETET95-ET<SEE1995EDDYCURRENTREPORTFORDETAILS.800200SG-ET----OPENGENERATOR TUBESOE100%OFALLUNSLEEVED TUBESETET95-ETsSEE1995EDDYCURRENTREPORTFORDETAILS800350B-QB16.20SLEEVEDGENERATOR TUBES20%ROT.RAN.SAM.EACHTYPESLEEVEASMEETETETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.a800360-------WEARIND.COLDLEG-2ND/3RD SPR1C10-RlC12, R2C106R2C12,R3C10-R3C12 OEET95-ET:ALLTUBESINSPECTED DURING1994.TUBESRlcloEcR1C12TUBESINSPECTED 1995.NODETECTABLE DEFECTSIDENTIFIED ACCEPTABLE. | |||
75 R.E~GINNANUCLEARPOWERPLANTrInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriodsThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ISTEAMGENERATOR EDDYCURRENTEXAMINATIONS CONT~H2,STEAMGENERATOR BSummaryExamNumberCategItemNumberComponent Component TypeNDEExam801000B-QB16.20OPENGENERATOR TUBESASMEPREV.IDENT.DEGRADE20%ETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.801150B-QB16.20OPENGENERATOR TUBESASME20%ROTATINGRANDOMSAMPLEETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.801200SG-ET----OPENGENERATOR TUBESOE100%OFALLUNSLEEVED 100%OFALLUNSLEEVED 95-ET!SEE1995EDDYCURRENTREPORTFORDETAILS.ETET801350B-QB16.20SLEEVEDGENERATOR TUBES20%ROT.RAN.SAMEACHTYPESLEEVEASMEETETETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.76 FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTS AsRcdluircd bytheProvisions ofthcASMECodeSectionXI1.OwnerRochester GasgElectricCor.Date24Gul199589EastAve.Rochester NY14649Sheet2.PlantR.E.GinnaNuclearPowerPlatttVnitof241503LakeRoadOntarioNY14519AddressRepairOrganization P.O.No.,JobNo.,ctc.3.WorkPerformed byNameTypeCodeSymbolStampAuthorization No.NANAAddressExpiration DateNA4.Identification ofSystemd.(lApplloOlCtooloCod~lp~Edloo,~Addd,CodeCase(b)Applicable EditionofSectionXIUtilizedforRepairsorReplaccmcnts 19866.Identification ofComponents RepairedorReplacedandReplacement Components NameofComponent NameofManufacturer Manufacturer SerialNo.NationalBoardNo.OtherIdcntiCicationYearBuildRepairedReplacedofReplaccmcnt ASMECodeStamped(YcsorNo)7.Description ofWork8.TestsConducted:(a) | |||
Hydrostatic 0Pneumatic 0NominalOperating Pressure0Other0PrcssurepsiTestTemp.'FNOTE:Supplcmcntal shcctsinformoflists,skctchcs, ordrawingsmaybeused,provided(I)sizeis8-1/2in.x11in.,(2)information initemsIthrough6onthisrcportisincludedoneachshcct,and(3)eachsheetisnumberedandthenumberofshcctsisrecordedatthetopof'thisform.()SceATI'ACHMENT II"FORAPPLICABLE INFORMATION (12/82)ThisForm(E00030)maybcobtainedfromthcOrderDept.,ASME,345E.47thSt.,NewYork,N.Y.10017I FORMNIS-2(Back)9.Remarks Applicable Manufacturer's DataReportstobcattachedCERTIFICATE OFCOMPLIANCE Wccertifythatthestatements madeinthcreportarecorrectandthisASMECode,SectionXI.repairorreplacement conlortns totherulesofthcN/ATypeCodeSymbolStampICcrtificat ofuo'nNo.N/AExpiration DateSinedF.A.KlcackiISIEnineerDate24JulOwnerorOwner'sDesignee, TitleN/A1995CERTIFICATE OFINSERVICE INSPECTION I,theundcrsigncd, holdingavalidcommission issuedbytheNationalBoardofBoilerandPressureVesselInspectors andtheStateorProvinceofNcwYorkandemployedbyHSBI/klCn.ofHartfordCT.haveinspcctcd thecomponents dcscribcd inthisOwner'sRcportduringtheperiod/toW9Mandstatethattothebestofmyknowledge andbclicf,theOwnerhasperformed examinations andtakencorrective mcasurcsdcscribcd inthisOwner'sRcportinaccordance withtheinspection planandasrequiredbytheASMECodc, SectionXI.Bysigningthiscertilicate neitherthcInspector norhisernploycr makesanywarranty, expressed orimplied,concerning theexaminations andcorrective measuresdescribed inthisOwner'sRcport.Furthcrmorc, ncithcrthcInspector norhiscmploycrshallbeliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfroinorconncctcd withthisinspection. | |||
AWE8.N.6ccrInspector's Signature Date7195'~Commissions NationalBoard,State,Province, andEndorsements (e)SeeATI'ACHMENT II"FORAPPLICABLE INFORMATION | |||
(~')Repair,Replacement orModification asidcntilied within"ATTACHMENT II | |||
RoE~ | RoE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester Gas8ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant,1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications: | ||
1986NoAddendaATTACHMENT IIREPAIRREPLACEMENT andMODIFICATION PROGRAMTheRepair,Replacement andModification (RR&M)Program,asidentified withinthe"Appendix B"ProgramoftheGinnaStationQualityAssurance Manual,identifies component jurisdiction andassociated requirements. | |||
Applicable Repair,Replacement orModification activities havebeenperformed inaccordance withASMESectionXICode,1986edition,noaddenda.Whenanitemundertherulesandrequirements ofthe"Appendix B"Programisfounddeficient, anEngineering "use-as-is" evaluation mayresult.Thisdetermination isindicated withintheISIProgramSummary,"Attachment I",fortheapplicable component withinthisreport.Ifthedeficiency resultsinaCodeRepair,Replacement orModification; thedeficiency willbeclassified asoneofthreecategorytypes.Thesecategorytypesshallconsistofa"CodeServiceInducedRejectable Indication", | |||
a"CodeRejectable Indication" anda"Corrective ActionActivity". | |||
A"CodeServiceInducedRejectable Indication" occurswhenacomponent undertheRR&MProgramcontainsanindication thatisbeyondASMESectionXICodeacceptable standards andwasdetermined tobe"ServiceInduced". | |||
"ServiceInduced"indications, stemmingfromInservice Inspection Examinations (ISI),shallrequireadditional expandedexaminations. | |||
Theassociated expandedexaminations shallbeperformed inaccordance totherequirements oftheASMESectionXICode.A"CodeRejectable Indication" occurswhenacomponent undertheRR&MProgramcontainsanindication thatisbeyondASMESectionXICodeacceptable standards andwasdetermined tobenot"ServiceInduced". | |||
Thiscategoryincludesbutisnotlimitedtoitemssuchasweldingdiscontinuities fromamodification identified duringISIpreservice examinations orcomponent damagecausedbyhumaninvolvement. | |||
R. | R.EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1~Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.Plant!R.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications: | ||
R.E. | 1986NoAddendaATTACHMENT IIA"Corrective ActionActivity" mayoccurwhenacomponent undertheRR&MProgramrequirescorrective action.Thiscorrective actionmaybearesultfromamaintenance operation thatidentifies aneedtoperformaCodeRepair,Replacement orModification. | ||
RaE. | Thiscategoryincludes'but.isnotlimitedtoitemssuchasmachining acomponent tocorrectanidentified problemortheremovalandlaterreapplication ofhardfacematerialonpressureboundarysurfaces. | ||
RE~ | Thefollowing groupshaveperformed applicable Repair,Replacement andModification activities duringthe1993Outage.Eachgrouphasbeenidentified byanumberandwillcorrespond tothegroups'ame andaddress.Rochester GasandElectric, GinnaStationdepartments willnotbeidentified aslikecontractors butbygenericname.InthebelowlistingofRepairs,Replacements orModifications; theworkgroupwillbeidentified byanumberwithinthecomponent discussion. | ||
RE. | Rochester Gas&Electric, GinnaStation2~GinnaStationProjectsDepartment NuclearPowerServicesPhiladelphia, Pa.3.ITIMovats2825CobbInternational Blvd.Kennensaw, Ga.30144-5512 4~5.ABB-Combustion Engineering, Inc.,1000ProspectHillRoadP.O.Box500Windsor,Connecticut 06095-0500 Babcock&WilcoxLynchburg, Virginia R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner!Rochester Gas8ElectricCo.89E.Ave.Rochester N.Y.146492~PlanttR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModifications: | ||
RaE~ | 1986NoAddendaATTACHMENT IIThefollowing information willreportapplicable Repairs,Replacements orModifications performed atR.E.GinnaNuclearPowerPlantduringthisreporting periodasrequiredbyASMESectionXICode.1~ASMEClass:3~Sstem:SWGORRNo.:95-E-001Construction Code:ASMESectionIII'86;B31.1'73;B16.34WorkPerformed B:1NameofComonent:V4620,SwivelNutWorkDescritionRemarks:An"Approved Equivalent" Replacement wasinitiated fortheSwivelNutassociated withV4620andtoreattachthedisctothestem.Thisactivitywascontrolled byWOk19402994&NCR94-106.Construction CodeVTexamination wasperformed andacceptable. | ||
Uponactivityconclusion, aVT-2LeakageExamination wasperformed | |||
&acceptable. | |||
2.ASMEClass:3~Sstem:SWGORRNo.:95-E-002Construction Code:ASMESectionIII'86;B31.1'73;B16.34WorkPerformed B:2NameofComonent:V4603ReliefReuest:g25WorkDescritionRemarks:AModification activitywasinitiated toreplaceV4603withaNozzleCheckValveandaFlangewithextendedlength.Thisactivitywascontrolled byEWR5284BandSM5284B.2.Construction CodeRTNDEwasperformed andacceptable inaccordance withthespecified ReliefRequest.AVT-2LeakageExamination wasperformed andacceptable. | |||
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner:Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.Plant!R.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofsectionXIUtilizedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II3~ASMEClass:2~Sstem:MSGORRNo.:95-E-003Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:MSU-18(South)Mechanical SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheMechanical Snubberassociated withComponent SupportMSU-18(South).Thisactivitywascontrolled byWOg19404245andNCR95-017.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable. | |||
4.ASMEClass:2~Sstem:SAEWGORRNo.:95-E-005Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:AFU-208Hydraulic SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheHydraulic Snubberassociated withComponent SupportAFU-208.Thisactivitywascontrolled byWOg19404248andNCR95-044.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable. | |||
5.ASMEClass:2~Sstem:MSGORRNo.:95-E-006Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:MSU-57Mechanical SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheMechanical Snubberassociated withComponent SupportMSU-57.Thisactivitywascontrolled byWOg19404247andNCR95-039.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable. | |||
RaE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1~Owner!Rochester gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlanttR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II6.ASMEClass:2~Sstem:SAFWGORRNo.:95-E-007Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:AFU-229Hydraulic SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheHydraulic Snubberassociated withComponent SupportAFU-229.Thisactivitywascontrolled byWOg19501481andNCR95-047.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable. | |||
7~ASMEClass:3~Sstem:SWGORRNo.:95-E-009Construction Code:ASMESectionIII86FB31~173B16~34WorkPerformed B:1NameofComonent:V4604ReliefReuest:g25WorkDescritionRemarks:AModification activitywasinitiated toreplaceV4604withaNozzleCheckValveandaFlangewithextendedlength.Thisactivitywascontrolled byEWR5284BandSM5284B.3.-ASMESectionIIIConstruction CodeRTNDEwasperformed andacceptable inaccordance withthespecified ReliefRequest.AVT-2LeakageExamination wasperformed andacceptable. | |||
(SeeGORR95-T-024). | |||
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications t1986NoAddendaATTACHMENT II8.ASMEClass:1~Sstem:RCS-S/GGORRNo.:95-E-010Line:N/AConstruction Code:ASMESectionIII'86WorkPerformed B:5NameofComonent:SteamGenerator "A&B"(EMSO1A,EMSO1B)Tubes,Explosive Sleeves/Plugs. | |||
WorkDescritionRemarks:DuringtheEddyCurrentExamination ofSteamGenerator "A&B",tubescontaining defectswereidentified anddetermined tobecandidates forB&Wbimetallic explosive sleevesorplugs.Atotalof75B&Wexplosive sleevesand3B&Wexplosive plugswasinstalled inthe"A"SteamGenerator. | |||
Atotalof91B&Wexplosive sleevesand8B&Wexplosive plugswasinstalled inthe"B"SteamGenerator. | |||
Thelocationofthesedefective tubesareidentified withintheEddyCurrent"1995FinalExamination ReportforSteamGenerators". | |||
Thisactivitywascontrolled byGinnaStationMaintenance Procedures M43.16&M43.43.3, andB&Wdocument51.-1212535-01. | |||
Uponcompletion oftheinstallation | |||
: activity, EddyCurrentexaminations wereperformed andacceptable onthesleeves.NoEddyCurrentexamination wasperformed onthePlugs.EddyCurrentSleeveExaminations arealsoutilizedtoverifyproperweldlocationandprovidescomparison toensureweldsoundness. | |||
RE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnertRochester Gas8ElectricCo.89E.Ave.Rochester N.Y.146492~Plant!R.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II9.ASMEClass:1~Sstem:RCS-S/GGORRNo.:95-E-011Line:N/AConstruction Code:ASMESectionIII'86WorkPerformed B:4NameofComonent:SteamGenerator "B"(EMS01B)Tubes,WeldedPlugs.WorkDescritionRemarks:DuringtheEddyCurrentExamination ofSteamGenerator "B",atotalof10tubescontaining defectswereidentified anddetermined tobecandidates forCEweldedplugs.Atotaloften(10)weldedCEPlugswereinstalled inthe"B"SteamGenerator. | |||
Thelocationofthesedefective tubesareidentified withintheEddyCurrent"1995FinalExamination ReportforSteamGenerators". | |||
Thisactivitywascontrolled byGinnaStationMaintenance Procedure M43.55andCEReportCEN-320-P.Uponcompletion oftheinstallation | |||
: activity, VTExaminations wereperformed andacceptable. | |||
10.ASMEClass:3~Sstem:MSGORRNo.:95-T-001Construction Code:B31.1'73/'86;B16.34WorkPerformed B:1NameofComonent:V3519,Studs&NutsWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated toinstallnewStuds&Nutsassociated withV3519.Thisactivitywascontrolled byWOg's19401812, 19402976andNCR94-103.Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
RaE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlanttR.E.GinnaNuclearpowerplant1503LakeRd.OntarioN.Y.145193~APPlicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications! | |||
1986NoAddendaATTACHMENT II11.ASMEClass:2~Sstem:CVCS-Letdown GORRNo.:95-T-003'":'"-"'/'-'onstruction Code:VIII'65;W676257;B31.1'55.WorkPerformed B:1NameofComonent:V203WorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated toinstallarebuiltspareReliefValveassociated withV203.Thisactivitywascontrolled byWOg's19402556, | |||
: 19401923, 19401901&19401833. | |||
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
12.ASMEClass:3~Sstem:MS~GORRNo.:95-T-004Construction Code:B31.1'86;B16.341SP-5291.WorkPerformed B:1NameofComonent:V3518Studs&NutsWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated toinstallnewStuds&Nutsassociated withV3518.Thisactivitywascontrolled byWOg19402162. | |||
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
13.ASMEClass:3~Sstem:SWGORRNo.:95-T-005Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291WorkPerformed B:1NameofComonent:PSW01C(SWPumpC)WorkDescritionRemarks:ServiceWaterPumpCBowlAssemblywithShaftwasreplacedwithapreviously rebuiltitems.Also;someboltingwasreplacedwithapprovedequivalent bolts.Thisactivitywascontrolled byWOg's19402122, 19321060andTSEE91-546.Uponreinstallation, anASMESectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.110 ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeri.od,ThirdOutage(1995)l.Owner:Rochester Gas5ElectricCo.89E.Ave.Rochester N.Y.146492.PlantiR.E.GinnaNuclearPowerPlant1503LakeRd.Ontari.oN.Y.145193~Applicable Editi:onofSectionXIUtilisedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II14.ASMEClass:3~Sstem:SWGORRNo.:95-T-006Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291WorkPerformed B:1NameofComonent:PSW01A(SWPumpA)WorkDescritionRemarks:ServiceWaterPumpABowlAssembly, Discharge CaseandShaftwasreplacedwithpreviously rebuiltitems.Thisactivitywascontrolled byWOg's19403555and19402161. | |||
Uponreassembly, anASME'SectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.115.ASMEClass:2~Sstem:SIGORRNo.:95-T-007-'"/'/'"Construction Code:ASMEIII83W85/'86.WorkPerformed B:1NameofComonent:V874E&Pipingdownstream V1820C.WorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated toinstallanewglobevalve(V874E)withassociated piping.Thisactivitywascontrolled byNCR94-169 andWOg19403601. | |||
Construction CodeVT&PTexaminations wereperformed andacceptable. | |||
AnASMESectionXIhydrostatic testwithaccompanying VT-2examination wasperformed underRSSP15.6andacceptable. | |||
16.ASMEClass:2~Sstem:SlGORRNo.:95-T-008Construction Code:ASMEIII83W85WorkPerformed B:1NameofComonent:V891CHingePin.WorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated fortheassociated HingePinofV891C.Thisactivitywascontrolled byWOg's19403641and19403627. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
11 | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriodsThirdOutage(1995)1~Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.plant:R.E.GinnaNuclearpowerplant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModificationst 1986NoAddendaATTACHMENT II17.ASMEClass:2~Sstem:BlowdownGORRNo.:95-T-009Construction Code:ASMEIII'74/86WorkPerformed B:1NameofComonent:BDU-21,RigidSupportWorkDescritionRemarks:Areplacement activitywasinitiated forBDU-21rigidsupportthatwasinadvetingly removedandrequiredreinstallation. | ||
Thisactivitywascontrolled byWO.g19403648andNCR94-102. | |||
Construction Codeexaminations wereperformed andacceptable. | |||
AnASMESectionXIvisualBaselineexamination wasperformed andacceptable. | |||
18.ASMEClass:3~Sstem:CCWGORRNo.:95-T-01010H-AC5-152 Construction Code:ASMEIII'86;B16.34WorkPerformed B:1NameofComonent:V780A/BFlangeStudsWorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated forFlangeStudsassociated withValves780A6B.Thisactivitywascontrolled byWOg19402526. | |||
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
19.ASMEClass:3~Sstem:SWGORRNo.:95-T-011Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291WorkPerformed B:1NameofComonent:PSW01C(SWPumpC)WorkDescritionRemarks:ServiceWaterPumpCBowlAssemblywithShaftwasreplacedwithpreviously rebuiltitems.Thisactivitywascontrolled byWOg's19404042and19403611. | |||
Uponreassembly, anASMESectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.1 R.EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester GasEElectricCo.89E.Ave.Rochester N.Y.146492.PlanttR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications: | |||
1986NoAddendaATTACHMENT II20.ASMEClass:3~Sstem:SWGORRNo.:95-T-013Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291;II'86.WorkPerformed B:1NameofComonent:PSW01B(SWPumpB)WorkDescritionRemarks:ServiceWaterPumpBBowlAssembly, Intermediate Shaft,ImpellerShaft,SuctionBellandassociated Boltingwasreplacedwithpreviously rebuiltornewitems.Thisactivitywascontrolled byWOg's19402721and19404138. | |||
Uponreassembly, anASMESectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.121.ASMEClass:3~Sstem:SWGORRNo.:95-T-014Construction Code:ASMEIII86)B31~155(RO2167WorkPerformed B:1NameofComonent:Expansion JointSSW04,SupportsSWU-629/633 Work.Descri tionRemarks:Areplacement activitywasinitiated foranewExpansion Joint,modifysupport.SWU-633andthereplacement ofmiscellaneous itemssuchasbolts,nutsect.Thisactivitywascontrolled byEWR5284B,TSR93-520, NCR94-128,SM-5284B.2 | |||
&WOg19404933. | |||
Afterinstallation, Construction CodeVTexaminations aswellasSectionXIbaselineexaminations wereperformed andacceptable. | |||
Also;ASMESectionXILeakageexamination wasperformed andacceptable. | |||
(Note:seeGORR95-E-002) 22'SMEClass:3~Sstem:CCWGORRNo.:95-T-016Construction Code:ASMEIII'74/'86WorkPerformed B:1NameofComonent:CCU-159RigidRestraint. | |||
WorkDescritionRemarks:Areplacement activitywasinitiated toinstallwashersinCCU-159,RigidRestraint Component Support,andalsototorqueHiltiBolts.Thisactivitywascontrolled byWOg19404910andNCR94-125. | |||
Uponinstallation, anASMESectionXIBaselineVTexamination wasperformed andacceptable. | |||
13 4tl R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492~PlanttR.E.GinnaNuclearPowerPlan81503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II23.ASMEClass:3~Sstem:AFWGORRNo.:95-T-017Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4000AStem&Disc.WorkDescritionRemarks:Areplacement activitywasinitiated toinstallanewStem&Discassociated withValve4000A.Thisactivitywascontrolled byWOg's19402916and19402936. | |||
BodytoBonnetweldareawaspreppedandanewSealWeldwasapplied.Construction CodePTexamination wasperformed andacceptable. | |||
Uponcompleting thereassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
24.ASMEClass:3~Sstem:SAFEGORRNo.:95-T-018Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9703BStem&Disc.WorkDescritionRemarks:Areplacement activitywasinitiated toinstallanewStem&Discassociated withValve9703B.Thisactivitywascontrolled byWOg19402953. | |||
BodytoBonnetweldareawaspreppedandanewSealWeldwasapplied.Construction CodePTexamination wasperformed andacceptable. | |||
Uponcompleting thereassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
25.ASMEClass:3~Sstem:SWGORRNo.:95-T-020Construction Code:B31.1'73;B16.34;ASMEIII'86.WorkPerformed B:1NameofComonent:V4622.ReliefReuest:g25WorkDescritionRemarks:AnApprovedEquivalent replacement activitywasinitiated toinstallasparevalvefromstockforV4622.Thisactivitywascontrolled byNCR94-009, TE93-548&WOg19400868. | |||
Construction CodeVT&PT(Root&FinalWeld)examinations wereperformed andacceptable. | |||
AnASMESectionXILeakageexamination wasperformed andacceptable. | |||
14 | |||
R.E~ | R.E~OINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester GasaElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.OinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRePairs,Replacements orModificationss 1986NoAddendaATTACHMENT II26.ASMEClass:1~Sstem:Pressurizer GORRNo.:95-T-021Construction Code:ASMEIII'83/'85/'86. | ||
WorkPerformed B:3NameofComonent:V515.WorkDescritionRemarks:AnApprovedEquivalent replacement activitywasinitiated toinstallanewvalve.Thisactivitywascontrolled byNCR94-068, EWR3755&WO¹19402868. | |||
Construction CodeRT&PTexaminations wereperformed andacceptable. | |||
ASMESectionXIBaselinePTexamination aswellasaHydrostatic Testwithaccompanying VT-2examination wasperformed andacceptable. | |||
27.ASMEClass:1~Sstem:Pressurizer GORRNo.:95-T-022Construction Code:ASMEIII'83/'85/'86. | |||
WorkPerformed B:3NameofComonent:V516.WorkDescritionRemarks:AnApprovedEquivalent replacement activitywasinitiated toinstallanewvalve.Thisactivitywascontrolled byNCR95-073 | |||
&WO¹19402865. | |||
Construction CodeRT&PTexaminations wereperformed andacceptable. | |||
ASMESectionXIBaselinePTexamination aswellasaHydrostatic Testwithaccompanying VT-2examination wasperformed andacceptable. | |||
28.ASMEClass:3~Sstem:SWGORRNo..95-T-023Construction Code:ASMEIII'86;B31.1'73WorkPerformed B:3NameofComonent:V4607WorkDescritionRemarks:A.Like-for-Like replacement activitywasinitiated forV4607Bolting&Stem.WeldRepairswerealsoperformed totheValveSeats&Disc.Thisactivitywascontrolled byWO¹19221485&MovatsDR95-05/-06/-08/-14. | |||
Construction CodePTexaminations fortheWeldRepairsoftheSeat&Discwereperformed andacceptable. | |||
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
15 R.EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester Gas6ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofsectionXIUtilizedforRepairs,Replacements orModifications: | |||
1986NoAddendaATTACHMENT II29.ASMEClass:3~sstem:SWGORRNo.:95-T-024Construction Code:ASMEIII'86FB31.1'55;RO-2167WorkPerformed B:1NameofComonent:Expansion JointSSW05,SupportsSWU-630/634 WorkDescritionRemarks:Areplacement activitywasinitiated foranewExpansion Joint,modifysupportsSWU-630/6343 andthereplacement ofmiscellaneous itemssuchasbolts,nutsect.Thisactivitywascontrolled byEWR5284B,TSR93-520, SM-5284B.3&WOg19500499. | |||
Afterinstallation, Construction CodeVTexaminations forthesupportsaswellasSectionXIbaselineexaminations wereperformed andacceptable. | |||
Also;ASMESectionXILeakageexamination wasperformed andacceptable. | |||
(Note:seeGORR95-E-009) 30.ASMEClass:3~Sstem:SWGORRNo.:95-T-026Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4608WorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated forV4608Stem.WeldRepairswerealsoperformed totheValveSeats&Disc.Thisactivitywascontrolled byWO19221483. | |||
Construction CodePTexaminations fortheWeldRepairsoftheSeat&Discwereperformed andacceptable. | |||
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
31.ASMEClass:3~Sstem:FWGORRNo.:95-T-027Line:4-FW-900-1 Construction Code:B31.1'73;B16.34;SP-5291FASMEIII'86.WorkPerformed B:3NameofComonent:V4271WorkDescritionRemarks:AReplacement activitywasinitiated toinstallanewStem,Cage&Plungerassociated withV4271.Thisactivitywascontrolled byTSR90-126 | |||
&WOg19402472. | |||
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
16 | |||
R.E. | R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner:Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492~PlanttR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications! | ||
RE. | 1986NoAddendaATTACHMENT II32'SMEClass:3~Sstem:SAFEGORRNo.:95-T-029.Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9701BWorkDescritionRemarks:AReplacement activitywasinitiated toinstallanewStemAssemblyassociated withV9701B.Thisactivitywascontrolled byWOg19402948. | ||
R.E~ | Uponreinstallation, anASMESectionXIVT-2examination wasperformed andacceptable. | ||
33.ASMEClass:2~Sstem:SAFWGORRNo.:95-T-030Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9704BWorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated forV9704BStem.Theworkactivityalsocoveredthereapplication oftheBodytoBonnetSealWeld.Thisactivitywascontrolled byWOg19402959. | |||
Construction CodePTexamination fortheSealWeldwasperformed andacceptable. | |||
AnASMESectionXIVT-2examination wasperformed,and acceptable. | |||
34.ASMEClass:2/3~Sstem:SAFWGORRNo.:95-T-031Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9704A;AFU-231WorkDescritionRemarks:Areplacement activitywasinitiated forV9704AStemandthereapplication oftheBodytoBonnetSealWeld.Component SupportAFU-231wasalsoremovedandreinstalled inordertoprovideaccessfortheoriginalworkscope.Thisactivitywascontrolled byWOg19402956. | |||
Construction CodePTexamination fortheSealWeldandVTexamination forthesupportwasperformed andacceptable. | |||
ASMESectionXIBaselineVTexamination forthesupportandVT-2examination wasperformed andacceptable. | |||
17 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModificationst 1986NoAddendaATTACHMENT II35.ASMEClass:3~Sstem:SWGORRNo.:95-T-032Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4668AWorkDescritionRemarks:Areplacement activitywasinitiated forV4668AStem.Thisactivitywascontrolled by,WO¹19221535. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
36.ASMEClass:3~Sstem:SWGORRNo.:95-T-033Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4561AWorkDescritionRemarks:Areplacement activitywasinitiated forV4561A.Thisactivitywascontrolled byWO¹19402895. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
37.ASMEClass:3~Sstem:MSGORRNo.:95-T-034Construction Code:ASMEIII'86;B31.1'73/'86;B16.34WorkPerformed B:1&3NameofComonent:V3518WorkDescritionRemarks:Areplacement activitywasinitiated forV3518Shaft&Keys.Weldrepairswerealsoperformed totheDiscArmandtheapplication ofTackWeldstotheNuttoDiscPost.ThisActivitywascontrolled byWO¹19402322andNCR95-021. | |||
Construction CodePTExaminations wereperformed ontheweldedareasandacceptable. | |||
Uponreassembly, anASMESectionXILeakageexamination (ISIExam95411400) wasperformed andacceptable. | |||
RE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner!Rochester Gas&ElectricCo.S9E.Ave.Rochester N.Y.146492.PlanttR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications! | |||
1986NoAddendaATTACHMENT II38.ASMEClass:3~Sstem:RCSGORRNo.:95-T-035Construction Code:B31.1'73/'86;B16.34;VIII'65;WE-676279WorkPerformed B:1NameofComonent:V434WorkDescritionRemarks:Thisactivitywasinitiated toreplaceV434witharebuiltunit,nointernalvalvecomponents werereplaced. | |||
Thisactivitywascontrolled byWOg19402658. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
39.ASMEClass:l~SstemRCSGORRNo.:95-T-036Construction Code:B31.1'73/'86;B16.34;VIII'65;WE-676279WorkPerformed B:1NameofComonent:V435WorkDescritionRemarks:Thisactivitywasinitiated toreplaceV435witharebuiltunit,nointernalvalvecomponents werereplaced. | |||
Thisactivitywascontrolled byWOg19402659. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
40.ASMEClass:3~Sstem:SWGORRNo.:95-T-037Construction Code:B31.1'73/'86;SP-5291WorkPerformed B:1NameofComonent:BlindFlangeNuts/Bolts Downstream ofV4640WorkDescritionRemarks:Thisactivitywasinitiated toreplaceassociated Nuts/Bolts ofBlindFlangeDownstream ofV4640.Thisactivitywascontrolled byWOg19500531. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications: | |||
1986NoAddendaATTACHMENT II41.ASMEClass:3~Sstem:DGGORRNo.:95-T-038Construction Code:B31.1'73/'86;SP-5291;ASMEVIIIWorkPerformed B:1NameofComonent:V5960&1FlangeNut/BoltWorkDescritionRemarks:Thisactivitywasinitiated toreplaceoneNut/BoltonaFlangeaswellasforreplacing V5960.Thisactivitywascontrolled byWOg19402512. | |||
Upon,reassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
42.ASMEClass:2~Sstem:MSGORRNo.:95-T-039Construction Code:B31.1'73;SP-5291;B16.34;ASMEIII'86WorkPerformed B:3NameofComonent:V3505AWorkDescritionRemarks:Thisactivitywasinitiated toreplacetheStem&Discassociated withV3505A.Thisactivitywascontrolled byWOI19501151. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
43.ASMEClass:3~Sstem:CVCS/CCWGORRNo.:95-T-040Line:N/AConstruction Code:ASMEVIIIWorkPerformed B:1NameofComonent:ECH05,Non-Regen Hx.WorkDescritionRemarks:Thisactivitywasinitiated toreplacetwo(2)StudsontheNon-Regenerative HeatExchanger. | |||
Thisactivitywascontrolled byWOg19221031. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andresultswereunacceptable. | |||
AnActionReport(95-202)wasgenerated. | |||
20 | |||
R.E~ | R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester GasaElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II44.ASMEClass:3~Sstem:AFWGORRNo.:95-T-041Construction Code:B31.1'73;SP-5291;ASMEIIX'86WorkPerformed B:3NameofComonent:V4010WorkDescritionRemarks:Thisactivitywasinitiated toreplacetheDi'scAssemblyassociated withV4010.Thisactivitywascontrolled byWOg19402939. | ||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
45.ASMEClass:2~Sstem:MS6B-MS-600-1B Construction Code:B31.1'73;ASMEIII'77/75&'86WorkPerformed B:3NameofComonent:V34116V3410WorkDescritionRemarks:Thisreplacement activitywasinitiated toinstallaDiffuser/Pilot PluginV3411andaStemPilotAssemblyinV3410.Theseactivities werecontrolled by.WOg's19402924and19402925. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
46.ASMEClass:2~Sstem:CSGORRNo.95-T-043Line:3A-SI-301 Construction Code:SP-5291;ASMEIII'74/'86WorkPerformed B:1NameofComonent:CSU-72,Component SupportWorkDescritionRemarks:Thisactivitywasinitiated toinstallanutonComponent SupportCSU-72.Thisactivitywascontrolled byWOg19501405. | |||
Uponassembly, propertorqueverification wasperformed andacceptable. | |||
Noadditional ASMESectionXXBaselineExaminations wereperformed sincethisComponent SupportislocatedonanExemptLine.21 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.Owner:Rochester Gas6ElectricCo.89E.Ave.Rochester N.Y.146492.Plant!R.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications! | |||
1986NoAddendaATTACHMENT II47.ASMEClass:2~Sstem:CVCSGORRNo.:95-T-044Construction Code:B31.1'73/'86;B16.34WorkPerformed B:1NameofComonent:V371WorkDescritionRemarks:Thisactivitywasinitiated toinstallaPlug/Stem Assemblyassociated withV371.Thisactivitywascontrolled byWO¹19501329. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
48.ASMEClass:2~Sstem:HHSGORRNo.:95-T-045Line:150-4Construction Code':B31.1'55;ASMEIII'86;SP-5291WorkPerformed B:1NameofComonent:CappedPenetrations 301&303WorkDescritionRemarks:Thisactivitywasinitiated toremoveHHSSystempipingandcappingPenetrations 301and302.Theworkwascontrolled byWO¹19320570&TSR93-067. | |||
Construction CodeVT&PTexaminations wereperformed andacceptable associated withtheendcaps.Uponcompletion ofthisactivity, anAppendixJPressureTestwasperformed | |||
&acceptable. | |||
49.GORRNo.:95-T-046Corrective ActionActivityASMEClass:3~Sstem:MS1.5D-MS-600-1 Construction Code:B31.173IASMEIII86B1634)SP5291WorkPerformed B:1NameofComonent:V8527&V8528WorkDescritionRemarks:Areplacement activitywasinitiated toinstallnewvalvesassociated withV8527&V8528.Theseactivities werecontrolled byWO¹'s19404707and19403598. | |||
Construction CodeVT&MTexaminations wereperformed andacceptable. | |||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
AnActionReport(95-171)wasgenerated fortheimproperapplication ofASMESectionXILeakageexamination. | |||
ReliefRequest¹30wasalsogenerated. | |||
22 | |||
ReE. | ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester Gas&ElectricCo.S9E.Ave.Rochester N.Y.146492~PlanttR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModifications: | ||
R~E' | 1986NoAddendaATTACHMENT II50.ASMEClass:3~Sstem:AFWGORRNo.:95-T-047Construction Code:B31.1'73:ASMEIII'86;B16.34;SP-5291WorkPerformed B:3NameofComonent:V4007WorkDescritionRemarks:Thisactivitywasinitiated toinstallanewStem&SeatRingsassociated withV4007.Thisactivitywascontrolled byWOg19501545. | ||
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable. | |||
51.ASMEClass:2~Sstem:SIGORRNo.:95-T-048Construction Code:B31.1'73;B16.34;ASMEIII'86WorkPerformed B:1NameofComonent:V1820CWorkDescritionRemarks:Thisactivitywasinitiated toreplaceV1820C.Thisactivitywascontrolled byWOg19403628. | |||
Construction CodeVT&PTexaminations wereperformed andacceptable. | |||
Uponcompletion ofthisactivity, anASMESectionXIHydroTestandaccompanying VT-2examination wasperformed andacceptable. | |||
23 S | |||
R~E'GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner:Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications: | |||
19S6NoAddendaATTACHMENT II52.ASMEClass:2~Sstem:S/GBlowdownGORRNo.:95-T-049Line:"B"LoopConstruction Code:B31.1'73;ASMEIII'74/'86.WorkPerformed B:1&2NameofComonent:S/GBlowdown"B"Loop;Piping&Supports, insideContainment. | |||
CodeCase:N-416WorkDescritionRemarks:Areplacement activityontheS/GBlowdownLoop"B"piping(2")andComponent Supportsinsidecontainment wasinitiated. | |||
PipingmaterialwasupgradedfromCarbonSteeltoChrome-Moly. | |||
Thisactivitywascontrolled byWOg19500287, TSR94-116, EWR4499andSM94-116.1. | |||
Construction CodeVT&MTexaminations onthe2"SocketWeldsaswellasRT&VTexaminations ontheone(1)ButtWeldwereperformed andacceptable. | |||
ExistingComponent Supports(BDU-5,BDU-11,BDU-15,&BDU-16)wereremovedforthisactivityandlaterreinstalled hadConstruction CodeVTexaminations performed andacceptable. | |||
AnASMESection.XILeakageexamination wasperformed andacceptable inaccordance withCodeCaseN-416.24 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, secondPeriod,ThirdOutage(1995)ATTACHMENT IIIEROSION/CORROSION (MINWALL) | |||
PROGRAMSUMMARYThissectionprovidesErosion/Corrosion examination detailsandinformation corresponding toitemsinspected duringthe1995Outage.Atotalof96itemswereexamined. | |||
Thebreakdown ofthistotalisasfollows:ComonentTeTotalNumberPipesElbowsReducersTeesExansionJointTotal513464196Thefollowing listsidentifies systemsofexaminedcomponents, systemcomponent resultsummaries, andcomponent resultdetails.SstemsofExaminedComonents:Component thickness measurements wereperformed onthefollowing systems.DWGNO.SYSTEMSM-1M-2M-4AM-4BM-7AM-10M-10AM-10BM-10CM-11AM-15AM-15BA/BF.W.PUMPDISCHARGE TO5A/BHEATERS5A/BF.W.HEATERSTOF.W.HEADERFEEDWATER CLEANUPTOCONDENSER FROM5A/BHPHEATERSFEEDWATER CLEANUPTOCONDENSER | |||
&CONDENSATE DEM.RINSEHEATERDRAINTANKDISCHARGE LOWPRESSUREDOWNCOMERS (WESTCONDENSER) | |||
LOWPRESSUREDOWNCOMERS TOL.P.H.(WESTCONDENSER) | |||
LOWPRESSUREDOWNCOMERS (EASTCONDENSER) | |||
LOWPRESSUREDOWNCOMERS TOL.P.H.(EASTCONDENSER) | |||
MSR1A&1B2NDPASSDRAINMSR1A4THPASSTO5AHEATERMSR1B4THPASSTO5AHEATER 00 REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIISstemsofExaminedComonents:Cont.DWGNO.SYSTEMSM-16M-31M-41AM-41BM-75M-81M-88DM-90M-91M-105MSR1A&1B4THPASSTOCONDENSER MSR1A&1BTOHEATERDRAINTANK&CONDENSER 5AHPHEATERDRAINTO4ALPHEATER5BHEATERDRAINTO4BHEATERSTEAMEXTRACTION TO5A&5BHEATERSFEEDWATER DISCHARGE (TURBINEBLDG)S/GBLOWDOWNTOFLASHTANK(TURBINEBUILDING) | |||
FEEDWATER CLEANUP(CV-18)FEEDWATER CLEANUP(CV-19)HEATINGSTEAMSstemComonentResultSummaries: | |||
Thefollowing breakdownbysystemprovidesgeneralresultsonthecomponent typesthatwereexamined. | |||
DWGNO.SYSTEMM-1A/BFoWPUMPDISCHARGE TO5A/BHEATERSComponents Examined: | |||
Results:4ofNominal2Elbows4Acceptable 2PipesM-25A/BF.W.HEATERSTOFW.HEADERComponents Examined: | |||
Results:4ofNominal2Elbows1Acceptable 2Pipes3>88 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIISstemComonentResultSummaries: | |||
Cont.DWGNO.SYSTEMM-4AFEEDWATER CLEANUPTOCONDENSER FROM5A/BHPHEATERSComponents Examined:'esults: | |||
4ofNominal1Pipe1>88M-4BFEEDWATER CLEANUPTOComponents Examined: | |||
2Elbows2Pipes2ReducerCONDENSER | |||
&CONDENSATE DEM.RINSEResults:>ofNominal2>88288-82182-76176-70M-7AHEATERDRAINTANKDISCHARGE Components Examined: | |||
Results:4ofNominal2Elbows1Acceptable 1Expansion Joint4>881Pipe1ReducerM-10LOWPRESSUREDOWNCOMERS (WESTCONDENSER) | |||
Components Examined: | |||
Results:4ofNominal1Pipe1<65M-10ALOWPRESSUREDOWNCOMERS TOL.PH(WESTCONDENSER) | |||
Components Examined: | |||
Results:4ofNominal5Pipes182-764<65M-10BLOWPRESSUREDOWNCOMERS (EASTCONDENSER) | |||
Components Examined: | |||
Results:%ofNominal1Pipe1<65M-10CLOWPRESSUREDOWNCOMERS TOL.P.H(EASTCONDENSER) | |||
Components Examined: | |||
Results:~ofNominal3Pipes170-652<65 | |||
R.E. | R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)/ATTACHMENT IIISstemComonentResultSummaries: | |||
Cont.DWG~NO.SYSTEMM-11AMSR1A&1B2NDPASSDRAINComponents Examined: | |||
Results:9ofNominal1Elbow2>881PipeM-15AMSR1A4THPASSTO5AHEATERComponents Examined: | |||
Results:4ofNominal4Elbows10>885Pipes1TeeM-15BMSR1B4THPASSTO5AHEATERComponents Examined: | |||
Results:4ofNominal1Elbow1>88M-16MSR1A&1B4THPASSTOCONDENSER Components Examined: | |||
Results:4ofNominal1Pipe188-82M-31MSR1A&1BTOHEATERDRAINTANK&CONDENSER Components Examined: | |||
Results:4ofNominal5Elbows13>887Pipes1TeeM-41A5AHPHEATERDRAINTO4ALPHEATERComponents Examined: | |||
Results:%ofNominal3Elbows5>882PipesM-41BSBHEATERDRAINTO4BHEATERComponents Examined: | |||
Results:4ofNominal3Elbows4>882Pipes188-82 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeri.od,ThirdOutage'(1995) | |||
ATTACHMENT IIISstemComonentResultSummaries: | |||
Cont.DWG~NOSYSTEMM-75STEAMEXTRACTION TO5AComponents Examined: | |||
2Elbows3Pipes1Tee5BHEATERSResults:cofNominal1Acceptable 1Unacceptable 2>88176-70170-65M-81FEEDWATER DISCHARGE (TURBINEBLDG)Components Examined: | |||
Results:4ofNominal2Elbows5>883Pipes188-822Reducers1<65M-88D'S/G BLOWDOWNTOFLASHComponents Examined: | |||
2Elbows6Pipes1TeeTANK(TURBINEBUILDING) | |||
Results:4ofNominal7>88176-701<65M-90FEEDWATER CLEANUP(CV-18)Components Examined: | |||
Results:4ofNominal1Elbow182-761Pipe176-70M-91FEEDWATER CLEANUP(CV-19)Components Examined: | |||
Results:4ofNominal1Elbow1>881Reducer188-82M-105HEATINGSTEAMComponents Examined: | |||
1Elbow2PipesResults:4ofNominal3>88 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)/ATTACHMENT IIIComanentResultDetails:Thefollowing listprovidesexamination resultdetailsoncomponents | |||
,bydrawingnumberandsystemdescription. | |||
The."Component Type"classification specified inthelistbelowcorresponds tothefollowing: | |||
P=PipeR=Reducer/Expander E=ElbowT=TeeJ=Expansion JointDrawingNo.M-1System:A/BFWPUMPDISCHARGE TO5A/BHEATER-.SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth200270272002802820030030P0.938E0.938P0.938E0.9380.604NA>880.703NA>880.604NA>880.701NA>88VTVTVT'DrawingNo.M-2System:5A/BFEEDWATER HEATERSTOFEEDWATER HEADERSummaryNumberComp.Comp.NominalNominalIDTeWall1Wall2MinimumMinimumPercentNDEAllowable ReadinNominalMeth20113013201140142011501520116016E0.938P0.938E0.938E0.9380.7050.7100.961>881.009>88UTUT0.704NA>88VT0.6050.864>88UTDrawingNo.M-4ASystem:FEEDWATER CLEANUPTOCONDENSER/EAST WALLSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth20331031P0.5000.2500.603>88UT RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriodiThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-4BSystem:FEEDWATER CLEANUPTOCONDENSER/EAST WALLSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth20451051R0.5000.5940.350,0.416 0.49188-82UT2045205220459059204600602046306320464064E0.594E0.594P0.594R0.594P0.6880.6880.4160.571>88UT0.416,0.482 0.46776-70UT0.4820.675>88UT0.4160.50388-82UT0.4160.467.82-76UTDrawingNo.M-7ASystem:HEATERDRAINTANKDISCHARGE | |||
~~~~~~SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth2070100120702002E0.688P0.68820703003E0.68820704504AJ0.68820705005R0.6880.7500.2780.2740.2780.695>88UT0.646>880.630>88UTUTVTUTNANA0.278,0.303 0.786>88DrawingNo.M-10System:LOWPRESSUREDOWNCOMERS SummaryNumberComp.Comp.NominalNominalMinimumIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth2110601FP0.3750.1130.236(65UT | |||
R.E. | R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-10ASystem:STEAMEXTRACTION TO2ALPHSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth2121801821219019212250252122602621227027P0.375P0.375P0.375P0.375P0.3750.1130.150<65UT0.1130.1130.156<65UTHoles<65UT0.1130.140<65UT0.1130.28582-76.UTDrawingNo.M-10BSystem:LOWPRESSUREDOWNCOMERS tSummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth2130602FP0.3750.1130.159<65UTDrawingNo.M-10CSystem:STEAMEXTRACTION TO2BLPHSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDE~NumberIDTeWall1Wall2Allowable ReadinNominalMeth214130132141401421415015P0.375P0.375P0.3750.1130.1130.1130.120<65Holes<65UTUT0.25470-65UTDrawingNo.M-11ASystem:MSR1A&1B2NDPASSDRAINSSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth21508008E0.4320.2680.390>88UT21509009P0.4320.2670.401>88UT | |||
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
.i~R.E~ | : Interval, SecondPeriod,ThirdOutage(1995)/ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-15ASystem:MSR1A4THPASSTOHEATER5ASummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth22601001226020022260252A22603003P0.432E0.432P0.432E0.43222610510AE0.3002261101122612012T0.300P0.30022604004P0.43222609009E0.30022610010-P0.3000.2660.2660.2660.2660.2660.1710.1680.1750.1710.1680.499>880.385>880.398>880.397>880.390>880.284>880.275>880.266>880.289>880.284>88UTUTUTUTUTUTUTUTUTDrawingNo.M-15BSystem:MSR1B4THPASSTOHEATER5B,SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth22721073E0.3000.1690.273>88UTDrawingNo.M-16System:MSR1A&1B4THPASSDRAINTOCONDENSER SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth22801001P0.3000.1680.26388-82UT R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | ||
: Interval, SecondPeriod,ThirdOutage(1995)1ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-31System:MSR1A&1BTOHEATERDRAINTANKSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth'602502526026026e260270,272602802826028128A26028228B2'6028328C26037037E0.432P0.432T0.432P0.432E0.432P0.432E0.432P0.43226009009E0.43226010010P0.43226011011E0.43226012012P0.43226024724CP0.4320.1680.1660.168,0.1660.3780.3780.3780.3780.3780.3780.3780.3780.3780.473>880.417.>880.414>880.418>880.403>880.420>880.412>880.448>880.390>880.387>88UTUTUTUTUTUTUTUTUT0.408>88UT0.388>88UT0.419>88UTDrawingNo.M-41ASystem:5AH.P.H.DRAINTO4AL.P.H.SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth2900121A2900131C2900141D2900151E2900171FE0.687E0.687P0.432E0.432P0.4320.4320.6010.688>880.3780.3780.3780.412>880.417>880.411>880.601,0.378 0.678>88UTUTUTUT,UT10 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, secondPeriodIThirdOutage(1995)/ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-41B8ystem:5BH.P.H.DRAINTO4BL.P.H.SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth-291012"40AE0.68729101340CE0.68729101440DP0'.43229101540EE0.43229101640FP0.4320.4320.6010.656>88UTUTUT0.3780.3780.406>88UT0.38088-82UT0.601;0.378 0.621>880.3780.418>88DrawingNo.M-75System:STEAMEXTRACTION TO5A&5BH.P.H.~~~~SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth3031201230313013303140143031501530317017P0.375E0.375E0.375P0.375T0.37530320520AP0.3750.2320.2310.2250.2140.2300.2300.26476-70UT0.353>88UTNAOKVTNAOKVT0.367>88UT0.25470-65UTDrawingNo.M-81System:FEEDWATER DISCHARGE SummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth39009009P0.93839006006R0.8440.93839006506AP0.9380.6970.7100.6050.848>88UT0.954>880.863>88UTUT0.570,0.705 0.475<65UT11 R.EGINNANUCLEARPOWERPLANTrInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:DrawingNo.M-81(Cont.)SummaryComp.Comp.NominalNumberIDTeWall1Cont.NominalMinimumWall2Allowable MinimumPercentNDEReadinNominalMeth390210213902302339024024R0.844E0.938P0.9380.9380.6970.6050.855>880.875>88UTUT0.637,0.699 0.72088-82UTDrawingNo.M-88DSystem:BLOWDOWNTOBLOWDOWNTANK(TURBINEBLDG.)SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth38514014P0.30038515015E0.30038516016P0.300385392,.39BP0.33738553053P0.30038554054E0.30038555055P0.30038575775BP0.33738580080T0.5000.5000.1700.1700.1680.1440.1700.1700.1680.1690.291>88UT0.284>88UT0.297>88UT0.25176-70UT0.283>880.291>880.284>880.303>88UTUTUTUTUT0.285,0.258 0.265<65DrawingNo.M-90System:FWRECIRCCV-18SummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth.30041040E0.43230044043P0.4320.3340.2870.34082-76UT0.31776-70UT12 | |||
.i~R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 | |||
: Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-91System:FWRECIRCCV-19SummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercent'NDE ReadinNominalMeth30079033R0~3370~4320~223I0~3380~342>88UT30082036E0.4320.3330.37488-82UTDrawingNo.M-105System:HouseHeatingSystemSummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth33102002E0.237P0.23733101001P0.2370.1660.1660.1660.223>880.240>880.218>88UTUTUT13}} |
Revision as of 11:51, 29 June 2018
ML17264A123 | |
Person / Time | |
---|---|
Site: | Ginna |
Issue date: | 07/24/1995 |
From: | ROCHESTER GAS & ELECTRIC CORP. |
To: | |
Shared Package | |
ML17264A122 | List: |
References | |
NUDOCS 9508080402 | |
Download: ML17264A123 (177) | |
Text
ROCHESTER GASANDELECTRICCORPORATION 89EASTAVENUESROCHESTER'Y 14649NUCLEARREGULATORY COMMISSION INSERVICE INSPECTION REPORTFORTHETHIRDINTERVAL(1990-1999)SECONDPERIODiTHIRDOUTAGE(1995)ATREGINNANUCLEARPOWERPLANTREVISION0JULY24i19959'508080402 950802PDRADOCK050002449PDR REGINNANUCLEARPOWERPLANTNUCLEARREGULATORY COMMISSION INSERVICE INSPECTION REPORTTHIRDINTERVAL(1990-1999)SECONDPERIODSTHIRDOUTAGE(1995)OWNERSDATASHEETDate:24July,1995Owner:Rochester GasandElectricCorporation 89EastAvenueRochester, NewYork14649IPlantLocationandUnitNo.:R.E.GinnaNuclearPowerPlantUnitOne1503LakeRoadOntario,NewYork14519Commercial 0eratinDate:July1970AlicableCode:ASMESectionXI,1986Edition,NoAddenda 0
R.EDGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)TABLEOFCONTENTSIntroduction andSynopsisSummaryofWorkAccomplished Class1Components Class2Components Class3Components HighEnergyComponents DesignBreakWeldExaminations Consequential BreakWeldExaminations Component SupportExaminations SteamGenerators SystemPressureTestingHydrostatic TestingLeakageTestingSectionXI,ServiceInducedRejectable Components-ExpandedExaminations SnubbersVisualExaminations Functional TestingSeismicSupportProgramErosion/Corrosion (Minwall)
ProgramAttachment IISIProgramExamination SummaryAttachment IIRepair,Replacement
&Modification ProgramSummaryAttachment IIIErosion/Corrosion (Minwall)
ProgramSummary1~
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)ZNTRODUCTION ANDSYNOPSISInservice Inspection (ISI)activities for1995wereperformed oncomponents withinClass1,2,3,HighEnergyPiping,SteamGenerator Tubes,SeismicSupportsandSnubbers.
ISIexaminations wereconcluded onMay4,1995.Examination methodsincludedVisual(VT),LiquidPenetrant (PT),MagneticParticle(MT),Ultrasonic (UT),Radiographic (RT),andEddyCurrent(ET).Functional Testing(FT)andSystemPressureTestswerealsoperformed.
Erosion/Corrosion examinations werealsoperformed duringthistime.Personnel involvedincludedRG&ELaboratory andInspection
- Services, SonicSystemsIncorporated, MasterLeeServicesCorporation, ABBCombustion Engineering Corporation, GinnaStationQualityControlandtheGinnaStationResults/Test Group.Additional SupportPersonnel includedindividuals fromthefollowing departments:
GinnaStationInsulators, Maintenance, Electricians, PipeFitters,HealthPhysics,TurbineMaintenance, RG&EGeneralMaintenance andtheMechanical Engineering GroupoftheNuclearEngineering
.Services Department.
ASMESECTIONXISUMMARYOFWORKACCOMPLISHED:
Uponconclusion ofthe1995Outage,56.14ofASMESectionXICoderequiredexaminations forthe,ThirdIntervalISIProgramhasbeencompleted.
Adetailedcomponent summaryofalloutageISIactivities withtheirassociated resultscanbefoundwithin"Attachment I".CLASS1COMPONENTS:
Atotalof38ASME,Augmented orOwnerElectedcomponents wereexamined.
Theexaminations forthesecomponents consisted of2VT-3's,33PT's,and12UT's.Atotalof47examinations wereperformed onClass1Components.
R.EGINNANUCLEARPORERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS1COMPONENTS:
Cont.Class1examinations wereperformed onthefollowing items/systems and/orplantlines/component:
ItemSstemDescritionPlantLineComonentCVCS-Charging System:Regenerative HeatExchanger:
CVCS-Letdown System:HighPressureSafetyInjection System:Pressurizer:
Pressurizer System:2-CH5-2501 2B-CH5-2501 2C-CH5-2502 2A-CH5-2501 2I-CH5-2502 ECH02C2A-CH4-2501 10A-SI2-2501-B 2A-SI2-2501 2B-SI2-2501 TRC013A-RC8-2501-A 3A-RC8-2501-B 3A-RC8-2501 3B-RC8-2501 3C-RC8-2501 4A-RC8-2501-A ReactorCoolantPumpBItems:ReactorCoolantSystem:ResidualHeatRemovalSystem:PRC01B31-RC-2501-A31-RC-2501-B27.5-RC-2501-A,2D-RCO-2501-B 2B-RCO-2501-B 10A-AC7-2501-B R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS2COMPONENTS:
Atotalof63ASMEorOwnerElectedComponents wereexamined.
Theexaminations forthesecomponents consisted of3VT-1's,30VT-3's,21PT's,10MT's,2RT's,8UT's,and2VT-2'sforatotalof76examinations.
Class2examinations wereperformed onthefollowing items/systemsand/orplantlines/components:
ItemSstemDescritionComonentPulsation Dampener:
CVCS-Charging System:Feedwater System:HighPressureSafetyInjection System:Mainsteam System:SCH118A-CH-25022D-CH5-2501 2F-CH5-2501 14A-FW-900-1A 14B-FW-900-1B 10-SI-1518K-SI-151 4-SI-3014D-SI-1501 4E-SI-1501 3C-SI-1501 3E-SI-1501 30A-MS-600-1A 30B-MS-600-1B 6A-MS-600-1B 6B-MS-600-1A 6B-MS-600-1B ResidualHeatRemovalHeatExchanger:
EAC02AResidualHeatRemovalSystem:StandbyAux.Feedwater System:10-AC-60110A-AC-601 6-'AC-6016B-AC-6016D-AC-6013C-FW-902S-1A REDGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS2COMPONENTS:
Cont.ItemSstemDescritionPlantLineComonentServiceWaterSystem:8I-SW-125 8L-SW-125 8M-SW-125 6-SW-1256A-SW-125 6B-SW-125 6F-SW-125 6G-SW-125 CLASS3COMPONENTS:.
Atotalof119ASMEorOwnerElectedComponents wereexaminedutilizing theVT-3visualtechnique.
Examinations wereperformed onthefollowing items/systemsand/or'lant lines/components:
ItemSstemDescritionPlantLineComonentAuxiliary CoolingSystem:Auxiliary Feedwater System:14B-AC5-15214C-AC5-15210G-AC5-15210H-AC5-15210I-AC5-1528B-AC6-1526C-AC6-1526E-AC6-1526G-AC6-1525A-FW7-900-1 4A-SW-125-1B4A-SW-125-1C3A-FW7-900-1A 3A-FW7-900-1B 3E-FW7-900-1 3G-FW7-900-1 3H-FW7-900-1 3J-FW7-900-1 2A-FW7-900-1B 2C'-FW7-900-1A 1-5A-FW7-900-1 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)CLASS3COMPONENTS:
Cont.ItemSstemDescritionPlantLineComonentSealWaterHeatExchanger:
DieselGenerator System:Mainsteam System:ECH045C-DG-A6A-MS-600-1 6C-MS-600-1 StandbyAux.Feedwater System:ServiceWaterSystem:HIGHENERGYCOMPONENTS:
4A-FW8-152S-B 4G-SWO-152S 4F-SWO-152S 3A-FW8-902S-A 3A-FW8-902S-B 3C-FW8-902S 14D-SWO-125-1 14E-SWO-125-1 14G-SWO-125-1 14H-SWO-125-1 10B-SWO-125-1 6H-SWO-125-1 Nineteen(19)Augmen'ted orOwnerElecteditemsassociated withtheHighEnergyProgramwereexaminedduringthe1995Outage.Theexaminations fortheseitemsconsisted of15VT-1's,3VT-3's,16MT's,8RT's,and7UT'sforatotalof49examinations.
HighEnergycomponent examinations wereperformed onthefollowing items/systemsand/orplantlines:ItemSstemDescritionFeedwater System:Mainsteam System:PlantLine20-FW-900-1 14A-FW-900-1A 14B-FW-900-1 14B-FW-900-1B 36-MS-600-1 30A-MS-600-1 30B-MS-600-1 24B-MS-600-1A REDGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)STEAMGENERATOR TUBING:EddyCurrentASMEandOwnerElectedExaminations wereperformed ontubesinthe"A"and"B"SteamGenerators.
Thefollowing EddyCurrentexaminations wereperformed duringthe1995Outage:2.OpenGenerator Tubes,Previousindications greaterthanorequalto204wereexaminedtotheextentofdegradation asaminimum.OpenGenerator Tubes,204RandomSampleofallopenunsleeved tubeswereexaminedFullLength(F/L).3.OpenGenerator Tubes,100%ofallopenunsleeved tubeswereexaminedtothefirstSupportPlateontheHotLegsideasaminimum.4.SleevedGenerator Tubes,20%RandomSampleofeachtypeofsleevedgenerator tubeswereexaminedfromthesleeveendasaminimum.5.MRPCofallRow1U-BendsandRow2U-Bends.6.MRPCofRollTransition Regioninallopen,unsleeved tubes.7.Applicable WearIndications ColdLeg,TubesR1C10-R1C12.SteamGenerator EddyCurrentExamination detailsaredocumented intheRochester Gas&Electric1995SteamGenerator EddyCurrentFinalReport.SYSTEMPRESSURETESTS:Hdrostatic TestinNo10-YearISI(ASME)Hydrostatic testswereperformed duringthe1995Outage.
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)SYSTEMPRESSURETESTS:Cont.LeakaeTestinAtotalofsixteen(16)ASMEorAugmented LeakageExaminations wereperformed.
TheLeakagetestsincluded; one(1)Class1,ReactorCoolantSystem(PT-7)examination, fourteen(14)Class2or3examinations, andone(1)HighEnergyMainsteam examination.
Itshouldbenotedthatone(1)Class3examination waspartially completed duringthisrefueling outage.ASMESectionXIReuiredComonentsServiceInducedRe'ectable
-EandedExaminations:
TherewerenoASMESectionXIrequiredcomponents thatwereclassified as"ServiceInducedRejectable" thatneededCodeexpandedexaminations.
SNUBBERPROGRAM:VisualExaminations:
Atotalof23Snubbercomponent supportbaselineexaminations wereperformed duringthe1995outage.Snubbervisualexaminations wereperformed on'hefollowing items/systemsand/orplantlines:ItemSstemDescritionPlantLineAux.Feedwater System:3B-FW-900-lA3Z-FW7-900-1 3K-FW7-900-1 BlowdownSystem:CVCS-Letdown System:2C-MS-600-1B2A-CH4-151 2E-CH-601Feedwater System:14A-FW-900-1A 14B-FW-900-1B RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)SNUBBERPROGRAM:Cont.VisualExaminations:
ItemSstemDescritionMainsteam System:PlantLine30A-MS-600-1A 30B-MS-600-1B 6A-MS-600-1 6B-MS-600-1A 6B-MS-600-1B Pressurizer System:6AP-RC-6023B-RC8-2501 StandbyAux.Feedwater System:3C-FW-902S-1A 3C-FW-902S-1B SteamGenerator B:EMS01BFunctional TestinAtotaloftwenty-three (23)snubberswereFunctionally Tested(FT)duringthe1995outage.Fromthesixteen(16)snubbersthatwereoriginally scheduled, twelve(12)weremechanical snubbersandfour(4)werehydraulic snubbers.
Duetosnubberfailures, anexpansion wasperformed thatconsisted ofseven(7)additional snubbersthatwereFunctionally Tested.Scheduled SnubberFunctional Tests(FT)wereperformed onPlantLineslistedaboveunderSnubberVisualexaminations.
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)SEISMICSUPPORTPROGRAM:Atotalofnine'(9)Augmented orOwnerElectedSeismicSupportswereexaminedutilizing theVT-3visualtechnique.
SeismicSupportexaminations wereperformed onthefollowing items/systems and/orplantlines:ItemSstemDescritionPlantLineCVCS-Charging System:Mainsteam System:Pressurizer System:ResidualHeatRemovalSystem:StandbyAux.Feedwater System:ServiceWaterSystem:2T-CH-151 6D-MS-600-1A 6E-MS-600-1B 6F-MS-600-1B 8-RC-6013C-WD-151
.5F-CD-152S 10C-SWO-125-1 EROSIONCORROSION MINWALLPROGRAM:Atotalof96itemswereexaminedduringthe1995Outage.Thebreakdown ofthistotalisasfollows:ComonentTePipesElbowsReducersTeesExpansion JointsTotalNumber5134641 REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)EROSIONCORROSION MINWALLPROGRAMCont.Component thickness measurements wereperformed onthefollowing systems:DWGNOSYSTEMM-1M-2M-4AM-4BM-7AM-10M-10AM-10BM-10CM-11AM-15AM-15BM-16M-31M-41AM-41BM-75M-81M-88DM-90M-91M-105A/BF.W.PUMPDISCHARGE TO5A/BHEATERS5A/BF.W.HEATERSTOF.W.HEADERFEEDWATER CLEANUPTOCONDENSER FROM5A/BHPHEATERSFEEDWATER CLEANUPTOCONDENSER
&CONDENSATE DEM.RINSEHEATERDRAINTANKDISCHARGE LOWPRESSUREDOWNCOMERS (WESTCONDENSER)
LOWPRESSUREDOWNCOMERS TOL.P.H.(WESTCONDENSER)
LOWPRESSUREDOWNCOMERS (EASTCONDENSER)
LOWPRESSUREDOWNCOMERS TOL.P.H.(EASTCONDENSER)
MSR1A&1B2NDPASSDRAINMSR1A4THPASSTO5AHEATERMSR1B4THPASSTO5AHEATERMSR1A&1B4THPASSTOCONDENSER MSR1A&1BTOHEATERDRAINTANK&CONDENSER 5AHPHEATERDRAINTO4ALPHEATER5BHEATERDRAINTO4BHEATERSTEAMEXTRACTION TO5A&5BHEATERSFEEDWATER DISCHARGE (TURBINEBLDG)S/GBLOWDOWNTOFLASHTANK(TURBINEBUILDING)
FEEDWATER CLEANUP(CV-18)FEEDWATER CLEANUP(CV-19)HEATINGSTEAM10 RE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)Thestatements madeinthisreportandattachments arecorrectandtheexaminations andcorrective measurestakenconformtotheRulesoftheASMECode,SectionXI.Preparedby:FrankA.KlpackiDateISIEngineerMichaelJ.SaporitoDateManager,Laboratory andInspection
- Services, Technical Performance andFieldInspections Certificate ofInservice InsectionI,theundersigned, holdingavalidcommission issuedbytheNationalBoardofBoilerandPressureVesselInspections andtheStateorProvinceofNewYorkandemployedbyTheHartfordSteamBoilerInsectionandInsurance Comanhaveinspected and/orverifiedthecomponents described withinthisreportandassociated Attachments duringthestatedreporting timeframe,andstatetothebestofmyknowledge andbelief,theOwnerhasperformed examination andcorrective measuresdescribed inthisReportinaccordance withtherequirements oftheASMECode,SectionXI.Furthermore, neithertheInspector norhisemployershallbeliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromorconnected withthisinspection.
ReviewedBy:Picac'fCPANII'sSignature 7u5~Date11 S
I.Owner2.PlantFORMNIS-1OWNERsSREPORTFORINSERVICE INSPECTIONS AsrequiredbythcProvisions ofthcASMECodeRulesRochester GasgElectricCor.89EastAve.Rochester N.Y.14649(NameandAddressofOwner)R.E.GinnaNuclearPowerPlant1503LakeRoadOntarioNY14519(NameandAddressofPlant)'.PlantUnit15.Commercial ServiceDateJul19707.Components Inspected 4.OwnerCertificate ofAuthorization (ifrequired) 6.NationalBoardNurnbcrforUnitNANAComponent orAppurtenance Manufacturer orInstaller Manufacturer orInstaller SerialNo.StateorProvinceNo.NationalBoardNo.(*)SEE"ATTACHMENT I"FORAPPLICABLE INFORMATION Note:Supplemental sheetsinformoflists,sketches, ordrawingsmaybcused,provided(1)sizeis8-1/2in.x11in.,(2)information initems1throughe6onthisrcportisincludedoneachshcct,and(3)eachshcctisnumberedandthenumberofsheetsisrecordedatthctopofthislorm.(12/86)Thisform(E0029)maybeobtainedfromthcOrderDept.,ASME,22LawDrive,Box2300,Fairfield, NJ07007-2300 FORMNIS-1.(Back)10.Applicable EditionsofSectionXI1986Addenda9.Inspection IntervalI'rom1990to1999NoII.AbstractofExaminations, Includealistofexaminations andastatcmcnt concerning statusofworkrequiredforcurrentinterval.
(*)12.AbstractofConditions Noted.(*)13.AbstractofCorrective MeasuresRccommcnded andTaken.(*)Wecertifythatstatements madeinthisrcportarecorrectandtheexaminations andcorrective mcasurcstakenconformtotherulesofthcASMECode,SectionXI.Ccrtificatc ofAuthorization No.(ifapplicable)
NAExpiration DateNADate24Jul1995SignedRochester GasdcElectricCoorationOwnerByCERTIFICATE OFINSERVICE INSPECTION I,theundcrsigncd, holdingavalidcommission issuedbythcNationalBoardofBoilerandPressureVesselInspectors andthcStateorProvinceofNewYorkandemployedbyHartfordSteamBoilerInsection8cInsurance Coman.ofHartfordCFhaveinspected thecomponents described inthisOwner'sReportduringthcperiodAPtoWM5~andstatethattothebestofmyknowledge andbelief,theOwnerhaspcrforrncd examinations andtakencorrective mcasurcsdescribed inthisOwner'sReportinaccordance withtheinspection planandasrequiredbythcASMECode,SectionXI.Bysigningthiscertilicate neithertheInspector norhisemployermakesanywarranty, expressed orimplied,concerning theexaminations andcorrcctivc measuresdcscribcd inthisOwner'sRcport.Furthermore, neithertheInspector norhisemployershallbcliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfromorconnected withthisinspection.
~~i+'5'..u~~Inspector's Signature Commissions NationalBoard,State,Province, andEndorscmcnts Date199SSEE<<ATTACHMENT I<<FORAPPLICABLE INFORMATION 0SiO RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.oommerci alServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT IA.CLASS1COMPONENTS tAlePRESSURIZER DRAWINGS'-4 SummaryExamItemNumberCategNumberComponent Component TypeNDEExam004700B-DB3.120SPLNASMESPRAYLINENOZ-INSRADSECTUT95-UT:NORECORDABLE INDICATIONS, 360DEGREESACCEPTABLE.
004800B-FB5.40RC-1000-MSW-1 SAFEEND-TO-NOZZLE (SPRAYLINE)ASMEPTUT95-PT!INSIGNIFICANTS L=O,W=1/8,UP,1/16"ROUND.UT!NORECORDABLE 6GEOMETRYS IDGEOMETRY.
>90%CODECOVERAGEOBTAINED-ACCEPTABLE.
A2eREGENERATIVE HEATEXCHANGER CDRAWINGS:
A-8ItemNumberB3.150Component Component TypeRHE-NlASMEVESSEL-TO-NOZZLE WELDNDEExamUT95-UT:NORECORDABLE INDICATIONS, UTLAMPERFORMED IN1986.APPROX.94%COVERAGEOBTAINED-ACCEPTABLE.
NOTE:"COMPONENT TYPE"ISDEFINEDASFOLLOWSt"ASME"=ITEMREQUIREDBYASMESECTIONXICODE"AUG"=AUGMENTED PROGRAM-ITEMREQUIREDBYNRCCOMMITMENT "OE"=OWNERELECTED-NONMANDATORY EXAMINATIONS
eReEe"GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT CLASS1COMPONENTS CONT~A3eREACTORCOOLANTSYSTEM-LOOP ADRAWINGS:
A-3BSummaryExamNumberCategnItemNumberComponent Component TypeNDEExam011820B-JB9.12PL-FW-XII-LR (XIII)ASMELONGITUDINAL SEAMWELDUT95-UTNORECORDABLE INDICATIONS
-ACCEPTABLE.
GREATERTHAN90tCOVERAGEOBTAINED.
RELIEFREQUESTTOBEGENERATED FORCASTMATERIAL.
012100B-JB9.11PL-FW-VIPUMP(RCP-A)-TO-PIPE ASMEUTPT95-PT:NORECORDABLE EcINSIGNIFICANT INDICATIONS-L=33.5CWSW=2.10"UP-0.15"LONG.L=39.4CW,WNN0.45amDOWNROUND015"-ACCEPTABLE.
UT:NORECORDABLE INDICATIONS ACCEPTABLE.
)90%.A4~REACTORCOOLANTSYSTEM-LOOP BDRAWINGS:
A-3FSummaryExamNumberCateg'013320B-JItemNumberComponent NDEComponent TypeExamUTPTB9.12.PL-FW-XI-LR (XV)ASMELONGITUDINAL SEAMWELD95-PTtINSIGNIFICANTS FABRICATION INDICATIONS
-ACCEPTABLE.
UT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
RELIEFREQUESTTOBEGENERATED DUETOCASTMATERIAL.
013500=B-JB9.11PL-FW-XVELBOW-TO-PUMP(RCP-B)
ASMEUTPT95-PTNORECORDABLE INDZCATIONS, SURFACECONDITIONING PERFORMED
-ACCEPTABLE.
UT:NORECORDABLE INDICATIONS
<90'tCODECOVERAGEOBTAINED.
RELIEFREQUESTTOBEGENERATED TOADDRESSCODECOVERAGEANDCASTMATERIAL-ACCEPTABLE.
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberrorUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.A5.3-IN.PRESSURIZER SPRAYLINEDRAWINGS:
A-10SummaryExamNumberCategItemNumberComponent Component TypeNDEExam015400B-JB9.21BSW-1PIPE-TO-ELBOW ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
019600B-JB9.21M-1PIPE-TO-REDUCER ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
019800B-JB9.21ANOZZLE-TO-PIPE ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
A6.2-IN.PRESSURIZER SPRAYLINEDRAWINGS:
A-llSummaryExamItemNumberCategNumber024000B-JB9.40Component 14PIPE-TO-COUPLING Component TypeASMENDEExamPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
025300B-JB9.4021ELBOW-TO-PIPE ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
025400B-JB9.4022PIPE-TO-VALVE(297)
ASMEPT95-PT$NORECORDABLE INDICATIONS
-ACCEPTABLE.
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit,14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT~A7a3-IN.PRESSURIZER RELIEFLINEDRAWINGS:
A-12SummaryExamItemNumberCategNumber026600B-JB9.21Component Component TypeCASMEOEREDUCER-TO-VALVE(515)
NDEExamPT95-PTsBASELINEEXAMINATION, NORECORDABLE INDICATIONS ACCEPTABLE-NOTE:CONSTRUCTION NDEONMAINTENANCE SUMMARYM95127.026700B-JB9.21DVALVE(515)-TO-PIPE OEPT95-PT:BASELINEEXAMINATION, NORECORDABLE INDICATIONS ACCEPTABLE.
NOTE1CONSTRUCTION NDEONMAINTENANCE SUMMARYM95127.027000B-JB9.21BREDUCER-TO-VALVE(516)
ASMEPT95-PT:BASELINEEXAM,NORECORDABLE INDICATIONS ACCEPTABLE.
NOTE:CONSTRUCTION NDEONSUMMARYM95132Ec.MOVATSREPORT95-36.027100B-JB9.21CVALVE(516)-TO-PIPE ASMEPT95-PT:BASELINEEXAM,NORECORDABLE INDICATIONS ACCEPTABLE.
NOTE:CONSTRUCTION NDEONSUMMARYM95132&MOVATSREPORTg95-36.
R.E.GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5C.ommercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.AS.4-IN.PRESSURIZER RELIEFLINEDRAWINGS:
A-13SummaryExamNumberCateg028200B-JItemNumberComponent B9.11QREDUCER-TO-ELBOW Component TypeASMENDEExamUTPT95-PT6UT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
100'tCOVERAGE.
A9~RESIDUALHEATREMOVALTOLOOPBCOLDLEGDRAWINGS:
A-14SummaryExamNumberCateg029100B-JItemNumberComponent Component TypeB9.11ASW-1ASMEPIPE-TO-ELBOW NDEExamUTPT95-PT6UT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
A10~H.P~SAFETYINJECTION LINETOLOOPBCOLDLEGDRAWINGS:
A-16SummaryExamNumberCateg033800B-JItemNumberB9.11Component FSW-1PIPE-TO-ELBOW Component TypeASMENDEExamUTPT95-PT6UT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
GREATERTHAN90%COVERAGEOBTAINED.
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.All.H.P,SAFETYINJECTION LINEDRAWINGSa A-19SummaryExamNumberCateg,038700B-JItemNumberB9.40Component FSW-19TEE-TO-REDUCER Component TypeASMENDEExamPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
041700B-JB9.40GSW-15ELBOW-TO-PIPE ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE A12~2"H.PSAFETYINJECTION TOLOOPBHOTLEGDRAWINGS:
A-21SummaryExamNumberCategItemNumberComponent Component TypeExam042200B-JB9.40GSW-202"PIPE-TO-BRANCH CONNECTION ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
A13.2"LETDOWNTOREGENHTXDRAWINGS:
A-23SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam044900B-JB9.4020ASMEPIPE-TO-ELBOW 95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
PT045425F-AF1.10RCVU-33GUIDEASME95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
R.E.GZNNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT~AleSEALWATERTORCP-A,DRAWINGS:
A-31SummaryExamNumberCateg049750B-JItemNumberComponent B9.4020ELBOW-TO-PIPE ASMEPTComponent TypeExam95PTREJECTf1/8ROUNDPOREfBLEEDOUT1/4ATFITTINGSIDE-TOEOFWELDORIGINALCONSTRUCTION, NCR95-030 GENERATEDS USEASIS~SURFACECONDITIONING PERFORMEDS POREREMOVED.PERFORMED VT&PTONCONDITIONED AREA,NORECORDABLE
-ACCEPTABLE.
049765B-JB9.4019PIPE-TO-ELBOW ASMEPT95-PT:NORECORDABLE INDICATIONS, GREATERTHAN90'tCOVERAGEOBTAINED,
-ACCEPTABLE.
A15e2"CHARGINGTOLOOPBCOLDLEGDRAWINGS:
A-25SummaryExamNumberCateg050740F-AItemNumberF1.10VComponent CVU-6VARIABLESPRINGComponent TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS, TEMP.73DEGFSETTING5/8"=801'Sf-ACCEPTABLE.
050745B-JB9.4021CTEE-TO-REDUCER ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
050750B-JB9.4022PIPE-TO-VALVE(295)
ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
0i REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul19706.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT.tA16~2"ALTERNATE CHARGINGTOLOOPACOLDLEGDRAWINGS:
A-26SummaryExamNumberCategItemNumberComponent Component TypeNDEExam051400B-JB9.4020ASMEVALVE(392B)-TO-PIPEPTUT95-PT:WELDNORECORDABLE INDICATIONS
-ACCEPTABLE VALVE(V392B)CASTINGSIDECONTAINSLARGEAMOUNTSOFPOROSITY(1/8TO3/8"),NOTSERVICEINDUCED.NCR95-033GENERATED.
UTTHICKNESS PERFORMED, AVERAGE~600"~USE-AS-IS PERENGINEERING
-ACCEPTABLE.
ASME052500B-JB9.4030ELBOW-TO-PIPE 95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
PT052700B-JB9.4032PIPE-TO-COUPLING ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
A16.2"ALTERNATE CHARGINGTOLOOPBHOTLEGDRAWINGS:
A-27SummaryExamNumberCateg054930B-JrItemNumberComponent NDEComponent TypeExamPTB9.409BASMEVALVE(9315)-TO-TEE 95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
054960B-JB9.409DASMETEE-TO-REDUCING INSERTPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
10 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial serviceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS1COMPONENTS CONT~Ale2"ALTERNATE CHARGINGTOLOOPBHOTLEGDRAWINGS:
A-27SummaryExamNumberCateg055300B-JItemNumberComponent B9.4012PIPE-TO-NOZZLE ASMEPTComponent TypeExam95-PTNORECORDABLE INDICATIONS
-ACCEPTABLE.
A18~REACTORCOOLANTPUMPBDRAWINGSNASummaryExamNumberCategItemNumberComponent Component TypeNDEExam058105FLYWHELRG-1.14RCP-BFLYWHEEL, EXPOSEAUGAREAS212-3D19156-Gol-02 PTUT95-PT&UT:EYWMINEDALLACCESSIBLE AREAS,NORECORDABLE INDICATIONS
-ACCEPTABLE.
058120----BOLTRCP-BANCHORBOLTSOEBOLTSUT95UTNORECORDABLE INDICATIONS FORSTUDSLlL4fMlM4fNlfN3sN4~OTHERSTUDL4IS117LONG~REJECTSTUDN2fINDICATION AT19.2",SEENCR94-056 FORRESOLUTION, NOAPPARENTCHANGESINCE1994EXAM.-ACCEPTABLE 11 R.E~GINNANUCLEARPOWERPLANTZnservice Znspection Report1990-1999 Intervals SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnitjNAATTACHMENT IB~CLASS2COMPONENTS tBl.2"CHARGINGFROMREGENHTXDRAWINGS:
A-25ASummaryExamNumberCategItemNumberComponent NDEComponent TypeExam050420C3.20CVU-60(IA)INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
050425---Fl.20ACVU-60ANCHOR(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
B2e2"ALTERNATE CHARGINGTOLOOPBHOTLEGDRAWINGS:
A-27SummaryExamNumberCateg054625ItemNumberComponent Component TypeC3.20CVU-48(IA)OEINTEGRALATTACHMENT NDEExamPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
054630----F1.20ACVU-48ANCHOR(ZA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
12
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT~B3PULSEDAMPENERDRAWINGS:
B-6SummaryExamNumberCateg075430F-AItemNumberComponent F1.20ACF-SlSUPPORT(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
075460F-AF1.20ACF-S2SUPPORT(IA)OEVT-395-VT-3:NORECORDABLE 6REJECTSLACKOFTHREADENGAGEMENT BY1THREADONNEHILTINUT,NOTSERVICEINDUCED.USE-AS-IS PERENGINEERING LETTERDATED5/25/95-ACCEPTABLE.
075500C-CC3.20CF-Sl(IA).INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
075600C-CC3.20CF-S2(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
13
R.E~GINNANUCLEARPOWERPLANTinservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970.6.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tB4eCHARGINGPUMPATOPULSEDAMPENERDRAWINGS:
B-6SummaryExamNumberCateg077500F-AItemNumberComponent F1.20RCVU-411RIGIDRESTRAINT (IA)Component TypeOENDEExamVT-395-VT-3sNORECORDABLE
&INSIGNIFICANTS POORWORKMANSHIP ONWELDREPORTEDON942074PTEXAMRECORD-ACCEPTABLE.
077501C-CC3.20CVU-411(IA)INTEGRALATTACHMENT ASMEPTVT-195-PT:REJSPOORWELDWORKMANSHIP ONORIGINALWELD.NCR94-133 GENERATED.
SURFCONDITIONED.
VT-1:NORECORDABLE
&INSIG:6"OF3/16"WELDROUGHONBACKSIDEPT:INSIGSIN6"OFWELDS11/4HASSLAGS&fINDICATIONS ON3LENGTHENACCEPTPERNCRREV2.B5~MAINSTEAMLOOPAOUTSIDECVDRAWINGS:
B-9SummaryExamNumberCateg080900F-AItemNumberComponent F1.20VMSU-45VARIABLESPRINGOEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS.
TEMP.106DEG.F.,NORTH=1935if'S(0.4"),SOUTH=2115f'S(0.6)ACCEPTABLE.
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999 Intervalf SecondPer'iod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS
'ONT~B6aMAINSTEAMLOOPAATMOSPHERIC VENTDRAWINGS:
B-9ASummaryExamNumberCateg083850C-F-2ItemNumberComponent C5.51G2-BC-2-B FLANGE(3507)-TO-PIPE NDEComponent TypeExamASMEVT-1MTRT95-VT-1&MT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
RT:NORECORDABLE
&INSIGNIFICANTS 5-10POROSITYAT71/2Ž0.031"-ACCEPTABLE.
084320F-AF1.208MSU-58MECHANICAL SNUBBEROEVT-395VT3BASELINEEXAMTEMP~75DEG~FfSETTING31/8fPSA-35"STROKESS/N18187.NORECORDABLE INDICATIONS ACCEPTABLE.
B7~MAINSTEAMLOOPBOUTSIDECVDRAWINGS:
B-10SummaryExamNumberCateg088830F-AItemNumberComponent F1.20RMSU-33GUIDE(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
088835C-CC3.20MSU-33(IA)INTEGRALATTACHMENT OEMT95-MT!NORECORDABLE INDICATIONS
&LIMITATIONSS ONLY50'tOFINTEGRALATTACHMENT WELDISACCESSIBLE DUETOASBUILTCONFIGURATION LIMITS-ACCEPTABLE.
15
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commeccial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT~!BS~MAINSTEAMLOOPBTOAUXFWPUMPTURBINEDRAWINGS:
B-10SummaryNumberExamCategItemNumber090300C-F-2C5.51Component L2-BC-1-A PIPE-TO-VALVE(3504)
Component TypeASMENDEExamRTVT-1MT95-MT:NORECORDABLE.
VT-1:NORECORDABLE
&INSIGNIFICANTS SLIGHTRUST&WELDPREP.RT:INSIGNIFICANTs SLAG,POROSITYS INTERNALCONCAVITY
-NOCHANGESINCELASTEXAMINATION ACCEPTABLE.
B9~MAINSTEAMLOOPBATMOSPHERIC VENTDRAWINGS:
B-10SummaryExamNumberCateg090820F-AItemNumberComponent F1.20SMSU-55MECHANICAL SNUBBERComponent TypeOENDEExamVT-395VT3BASELINEEXAMTEMP~74DEG~F~5SETTING213/16PSA-35"STROKE,S/N18195'.NORECORDABLE INDICATIONS ACCEPTABLE vB10.FEEDWATER LOOPAINSIDECVDRAWINGS!
B-12SummaryExamNumberCategItemNumberComponent Component TypeNDEExam093100F-AF1.20VFWU-2VARIABLESPRINGOEVT-395-VT-3:TEMP.65DEG.F.,SETTING2126ig'S.NORECORDABLE
&INSIGNIFICANTs LACKOFTHREADENGAGEMENT ONUPPERHANGERANCHOR&UPPERHANGERRODBENT.ACCEPTABLE PERNCRS83-132&92-147.093700C-F-2C5.51DD5PIPE-TO-ELBOW ASMERTMTVT-195-VT-1&MT:NORECORDABLE INDICATIONS
-ACCEPTABLE RT:NORECORDABLE
&INSIGNIFICANTs TUNGSTENQ305/8(1/32)5NOCHANGESINCELASTEXAMINATION
-ACCEPTABLE.
16
ReEGINNANUCLEARPOWERPLANTZnse&iceInspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6~Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tBll~FEEDWATER LOOPBOUTSIDECVDRAWINGS'-14 SummaryExamNumberCateg095200F-AItemNumberComponent Fl.20RFWU-45RIGIDRESTRAINT Component TypeOENDEExamVT-395-VT-3:NORECORDABLE 6INSIGNZFICANTS RESTRAINT BODYREVERSED-ACCEPTABLE.
B12.FEEDWATER LOOPBINSIDECVDRAWINGS:
B-130NumberCateg098100F-ASummaryExamItemNumberComponent F1.20VFWU-11VARIABLESPRINGOEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS, TEMP.69DEGF.fSETTING1/2"=2315=g'Sf-ACCEPTABLE.
B13.RESIDUALHEATREMOVALTOLOOPBCOLDLEGItemNumberComponent DRAWINGS:
B-17SummaryExamNumberCateg108450F-AComponent TypeExamVT-3F1.20APEN111ANCHORANCHOR(IA)OE95-VT-3-NORECORDABLE INDICATIONS
-ACCEPTABLE.
108451C-CC3.20PEN111ANCHOR(IA)ASMEINTEGRALATTACHMENT 95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
PT17 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commeucial ServiceDate~Jul1970B.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONTB14e6-IN,RESIDHTREMOVALTORPV(LHSI)DRAWINGSt B-17SummaryExamNumberCateg110650F-AItemNumberComponent F120RRHU-9RIGIDSUPPORT(IA)NDEComponent TypeExamOE95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE 110655C-CC3.20RHU-9(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE B15aHP.SAFETYINJECTION FROMRHRDRAWINGS!
B-19SummaryExamNumber~Categ120700C-F-1ItemNumberComponent 5REDUCER-TO-CROSS Component TypeOENDEExamPTUT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
UT:NORECORDABLE INDICATIONS fcGEOMETRY-ACCEPTABLE.
GREATERTHAN90'tCOVERAGEACHIEVED.
B16.H.P.SAFETYINJECTION LINE8K-SI-151 DRAWINGS:
B-19SummaryExamNumberCateg124200F-AItemNumberComponent F1.20RRHU-102RIGIDSUPPORT(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
124202C-CC3.20RHU-102(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
18
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial ServiceDate~Jul1975S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tB17eRESIDUALHEATREMOVALFROMLOOPAHOTLEGDRAWINGS:
B-20ASummaryNumber135350ExamItemCategNumberComponent F-AF1.20APEN140ANCHOR(IN/OUT)ANCHOR(IA)Component TypeOENDEExamVT-395-VT-3-NORECORDABLE INDICATIONS
-ACCEPTABLE 135351C-CC3.20PEN140ANCHOR(IA)(IN/OUT)
INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS OTHER:APPROX.1/8imOFWELD6THE1/2"INSPECTION AREAOUTSIDEOFTHETOEARENOTINSPECTABLE DUETOTHEINSTALLATION OFSTRONGBACK.APPROX.82%COVERAGEACHIEVED.
B18.RESIDUALHEATREMOVALTOLOOPBCOLDLEGDRAWINGS:
B-25SummaryExamNumberCateg145885F-AItemNumberComponent Fl.20RRHU-55RIGIDSUPPORT(IA)'EVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE 145890C-CC3.20RHU-55(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
19 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.Plant,R.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~cul197CS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.!B19eRESIDUALHEATREMOVALLINE6D-AC-601 DRAWINGS:
B-26SummaryExamNumberCateg147900F-AItemNumberComponent F1.20ARHU-95ANCHOR(IA)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
147910C-CC3.20RHU-95(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE SUCCESSIVE EXAM.B20~RESIDUALHEATREMOVALLINE6B-AC-601 DRAWINGS:
B-25SummaryExamNumberCateg151100F-AItemNumberComponent Component TypeF1.20RRHU-49OERIGIDSUPPORT(IA)NDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE 151120C-CC3.20RHU-49(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE B21,RESIDUALHEATREMOVALTOLOOPBCOLDLEGDRAWINGS:
B-25SummaryExamNumberCateg151700C-F-1ItemNumberComponent 1TEE-TO-PIPE Component TypeOENDEExamPTUT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
UT:NORECORDABLE INDICATIONS 6GEOMETRY-ACCEPTABLE.
GREATERTHAN90'tACHIEVED.
20 S
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul197CS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.B22.H.P.SAFETYINJECTION PUMPASUCTIONLINEDRAWINGS:
B-16BSummaryNumberExamCategItemNumberComponent Component TypeNDEExam160750F-AF1.20VRHU-118VARIABLESPRINGOEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
TEMP.110DEG.F~,SETTING9/16"=183g'S.RE-EXAMREQUIREDPERNCR94-024.
B23.H.P.SAFETYINJECTION LINE4D-SI-1501 DRAWINGS:
B-38SummaryNumberExamCateg161520F-AItemNumberComponent F1.20RSIU-41RIGIDRESTRAINT Component TypeOENDEExamVT-395-VT-3:SUCCESSIVE OWNERELECTEDEXAM,NORECORDABLE INDICATIONS
-ACCEPTABLE.
B24.H.P.SAFETYINJECTION LINE3C-SI-1501 DRAWINGS:
B-41SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam163020F-AF1.20RSIU-85RIGIDSUPPORT(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
SUCCESSIVE EXAM.163021C-CC3.20SIU-85(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
SUCCESSIVE EXAM21 eR.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial serviceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONTtB25.H.P.SAFETYINJECTION LINE3E-SI-1501 DRAWINGS:
B-42SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam163720F-AF1.20RSIU-62GUIDE(IA)OEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
163721C-CC3.20SIU-62(IA)INTEGRALATTACHMENT ASMEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
B26.H.P.SAFETYINJECTION LINE4E-SI-1501 DRAWINGS:
B-42SummaryExamNumberCateg163890C-F-1ItemNumberComponent C5.2128PIPE-TO-ELBOW ASMEPTUTNDEComponent TypeExam95-PT:INSIG-ROUNDINDICATION 1/32"DIA.L=87/8,CENTEROFWELDUT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
GREATERTHAN90%COVERAGEOBTAINED.
164180C-F-1C5.2147ELBOW-TO-PIPE ASMEPTUT95-PT6UT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
22 0
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnitjNAATTACHMENT ICLASS2COMPONENTS CONT~B27eRESIDUALHEATEXCHANGER ADRAWINGS:
B-109SummaryExamNumberCateg169041C-BItemNumberC2.33Component INSRHE-1A INLETNOZZLE-TO-SHELL WELDComponent TypeASMENDEExamVT-295-VT-2:TAKINGCREDITFOREXAMPERFORMED UNDERSUMMARYNUMBER413400IN1993,TESTWASACCEPTABLE.
169051C-BC2.33ONSRHE-1A ASMEOUTLETNOZZLE-TO-SHELL WELDVT-295-VT-2:TAKINGCREDITFOREXAMPERFORMED UNDERSUMMARYNUMBER413400IN1993,TESTWASACCEPTABLE.
B289SERVICEWATERLINE6G-SW-125 DRAWINGS:
B-50SummaryNumberExamCategItemNumberComponent NDEComponent TypeExam173020C-F-2*3OEREDUCINGELBOW-TO-PIPE MTUTVT-195-VT-1:INSIGSSURFACERUST6CORROSION OVERFULLPIPEAREA.RANDOMPITTING.MT:NORECORDABLE INDICATIONS.
UT:NORECORDABLE INDICATIONS
&GEOMETRY.
UT:WALLTHICKNESS
.246"ACCEPTABLE PERMECH.ENG.DESIGNANALYSISDA-ME-95-003.
WELDACCEPTABLE.
23 ReE.GZNNANUCLEARPOWERPLANTrInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6~Commercial ServiceDate~Jul1970B.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONT.tB29eSERVICEWATERLINEBM-SW-125 DRAWINGS!
B-50ASummaryNumberExamItemCategNumberComponent NDEComponent TypeExam173350---F1.20RSWU-78GUIDEOEVT-395-VT-3:NORECORDABLE INDICATIONS
&OTHERN'HIM (3"X1/2"X4")WELDEDINPLACEWITH3/16"FILLETWELDONEASTANDWESTSIDES.ACCEPTABLE PERME-121.NOINTEGRALATTACHMENT B30.SERVICEWATERLINE6F-SW-125 SummaryExamItemNumberCategNumberComponent 173505---F1.20APEN308ANCHORIII)ANCHOR(ZA)DRAWINGS:
B-50ANDEComponent TypeExam(TYPEOEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
173506----C3.20PEN308ANCHOR(IA)(TYPE ZII)INTEGRALATTACHMENT OEMT95-MTNORECORDABLE INDICATIONS
-ACCEPTABLE.
B31,SERVICEWATERLINE8L-SW-125 DRAWINGS:
B-50ASummaryNumber173530ExamCategItemNumberC-F-2*Component 43TEE-TO-PIPE Component TypeOENDEExamMTUTVT-195-VT-1:NORECORDABLE INDICATIONS
&INSZG:MINORPITTINGONBASEMETAL.MISALIGNMENT BETWEENPIPE&TEE.TEEODISLARGERTHANPIPE1/16"TO1/8"-ACCEPTABLE.
MT:NRZ-ACCEPTUT:NRI&GEOMETRY-ACCEPTABLE.
GREATERTHAN90'tACHIEVED.
24 R.E~GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthoriration (IfReq.)~NAS.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS2COMPONENTS CONTtB32~SERVICEWATERLINESI-SW-125 DRAWINGSsB-51CSummaryExamNumberCategItemNumberComponent Component TypeExam174140C3.20SWU-64(IA)INTEGRALATTACHMENT OEMT95-MT$NORECORDABLE INDICATIONS
-ACCEPTABLE.
174150---F1.20RSWU-64GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE B33.SERVICEWATERLINE6B-SW-125 DRAWINGS'-52B SummaryExamNumberCateg175205ItemNumberComponent F1.20APEN315ANCHOR(TYPEIII)ANCHOR(IA)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE 175206----C3.20PEN315ANCHOR(IA)(TYPE III)INTEGRALATTACHMENT OEMT95-MT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
25 RaE.GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999
- Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197D6.'National BoardNumberforUnitjNA~ATTACHMENT ICLASS2COMPONENTS CONTB34.SERVICEWATERLINE6A-SW-125 DRAWINGS:
B-53SummaryNumber175310ExamCategItemNumberComponent, C-F-2*3REDUCINGELBOW-TO-PIPE Component TypeOENDEExamMTUTVT-195VT1NRI5ZNSIG6OTHERNRANDOMPITTING(SEEEXAMSHEET),MEDIUMRUST-ACCEPTABLE MT!NRI6OTHER;RANDOMPITTING,NOWELDDEFECTSFOUND-ACCEPTABLE.
UT.NORECORDABLE INDICATIONS 6GEOMETRY-ACCEPTABLE.
GREATERTHAN90'tACHIEVED.
175325OEF1.20APEN312ANCHOR(TYPEIII)ANCHOR(IA)95-VT-3tNORECORDABLE
&INSIGNIFICANTS VENTLINEISEMBEDDEDINCONCRETE-ACCEPTABLE VT-3175326----C3.20PEN312ANCHOR(IA)(TYPE III)INTEGRALATTACHMENT OEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
B35.SERVICEWATERLINE6-SW-125DRAWINGS:
B-53ASummaryNumberExamCategItemNumberComponent'omponent TypeNDEExam175885Fl.20APEN323ANCHOR(TYPEOEIII)ANCHOR(IA)VT-395-VT-3sNORECORDABLE 6INSIGNZFICANTB VENTLINEEMBEDDEDZNCONCRETE-ACCEPTABLE.
175886----C3.20PEN323ANCHOROE(IA)(TYPE III)INTEGRALATTACHMENT 95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
PT26 0
R.EeGINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester GasfElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfReq.)~NAB.Commercial BerviceDate~Jul19706.National BoardNumberforUnitN~AATTACHMENT ICLASS2COMPONENTS CONT~tB36.STANDBYAUXFWTHRUPEN119TOAS/GFWHDINCVDRAWINGS:
C-20SummaryExamNumberCateg176120ItemNumberComponent F1.20RAFU-217(AFW-19)GUIDE(IA)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
176121---C3.20AFU-217(AFW-19)(IA)OEINTEGRALATTACHMENT 95-MT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
MT27
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriodfThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntario-NY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT IC.CLASS3COMPONENTS:
Cl.SEALWATERHEATEXCHANGER DRAWINGS:
B-4SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam073150F1.40SlSUPPORTLEGSiOEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE 073160----F1.40S2SUPPORTLEGP2OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
e073200----D2.20SlSUPPORTLEG$1-IAOEPT95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
073300----D2.20S2OESUPPORTLEGg2-IA95-PT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
PTC2~DIESELGENERATOR AJSW.COOLINGRETURNDRAWINGStC-35SummaryExamNumberCategItemNumberComponent Component TypeNDEExam500120D-BD2.20DG-1A(IA)ASMEVT-3INTEGRALATTACHMENT 95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:NODRAWINGAVAILABLE
-3/16"FILLETWELDS.500125F-AF1.30RDG-1ARIGIDSUPPORT(IA)OEVT-395-VT-3NORECORDABLE INDZCATIONS
-ACCEPTABLE.
NOTE:NODRAWINGAVAILABLE.
28 0
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfReq.)~NAB.Commercial ServiceDate~Jul1970B.National BoardNumberforUnitjNAATTACHMENT ICLASS3COMPONENTS CONTtC2.DIESELGENERATOR AJ'.W.COOLINGRETURN(Cont.)SummaryExamNumberCateg500130D-BItemNumberComponent D2.20DG-2A(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE NOTE:NODRAWINGAVAILABLE, 3/16"FILLETWELDS.500135F-AF1.30RDG-2ARIGIDSUPPORT(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:NODRAWINGAVAILABLE.
C3.AUX'OOLING WTReFROMNON-REG.HT.EXCH.DRAWINGS'-3 SummaryExamNumberCateg500320F-AItemNumberComponent F1.30RCCU-106RIGIDRESTRAINT OENDEComponent TypeExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
INSIG:CHIPPEDPAINT-ACCEPTABLE.
OWNERELECTEDEXPANDEDEXAMFORNCR94-129
&fNCR94-130.
500360F-AF1.30RCCU-110RIGIDHANGEROEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
OWNERELECTEDEXPANDEDEXAMFORNCR94-129
&NCR94-130 500370F-AF1.30RCCU-111RIGIDHANGEROEVT-395-VT-3:NORECORDABLE INDICATIONS-ACCEPTABLE.
NOTE:2LUGSONEITHERENDOFU-BOLTLUGSAPPEARTOBEOLDSADDLESCUT-OUT,APPROX.3/4TO1"LONGW/3/16"FILLETWELDSASANINTEGRALATTACHMENT-ACCEPTABLE.
OEEXPANDEDEXAMFORNCR94-129
&6NCR94-130.
29
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~C4~COMPeCOOL.HT.EXCHS.TO RESIDUALHT.EXCHS~DRAWINGStC-4SummaryNumberExamCateg500530D-BItemNumberComponent Component TypeD2.20CCU-138(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3:NORECORDABLE 66INSIGSLUGI3UNDERSIZE WELD4"(1/8"FILLET)FROMTOPTOBOTTOM.LUG/4UNDERSIZE WELD71/2TO8FROMTOPS<1/16f1/2INLENGTHUNDERCUT84"FROMTOP1"INLENGTH<1/32meOKPERENG.ORIGINALCONSTRUCTION
-ACCEPTABLE.
F1.30RCCU-138GUIDE(IA)OEVT-395-VT-3:NORECORDABLE 66INSIGNIFICANTS PAINTEDSURFACE,SLIGHTRUST-ACCEPTABLE.
500610D-BD2.20CCU-146(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
500615F-AF1.30RCCU-146GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
CS~COMP~COOL.PMPS.SSUC.FM RES.HT~EX'6SG.TKDRAWINGS:
C-6SummaryExamNumberCategItemNumberComponent Component TypeNDEExam500760D-BD2.20CCU-156(IA)OEINTEGRALATTACHMENT VT-3MT95-VT-3$NORECORDABLE INDICATIONS
-ACCEPTABLE'T NORECORDABLE INDICATIONS, AUGMENTED EXAM.-ACCEPTABLE.
OWNERELECTEDEXPANDEDEXAMFORNCR94-124.
30 R.E~GZNNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearpowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfReq.)~NAB.oommeccial BerviceDate~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS
.CONT.C5~COMP.COOL.PMPS.,SUC.FM RES.HT.EX.
&SG.TK(Cont.)SummaryNumberExamCateg500765F-AZtemNumberComponent F1.30RCCU-156RIGIDSUPPORT(IA)OEVT-3NDEComponent TypeExam.95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
INSIG:1/8"SHIMONWESTSIDE6NORTHWESTCORNEROFSUPPORTACCEPTABLE OWNERELECTEDEXPANDEDEXAMFORNCR94-124 500770D-BD2.40CCU-158(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE INSIG:LIGHTRUST,SOMECHIPPEDPAINT-ACCEPTABLE.
500775F-AF1.30VCCU-158VARIABLESPRING(IA)OEVT-3VT-395-VT-3:REJ:OWNERELECTEDEXAM,W.SPRINGCANUPPERATTACHLOOSENUT,SPACERMISSINGONLOWERE.SIDEOFCLAMP.SPRINGCANSOFFSCALE.NCR94-124 GENERATED-SERVICE INDUCEDVT3REEXAMfNRI6INSIGTEMP~73DEGF6SETTING1333gSE.E<W.-ACCEPT.
500780F-AF1.30RCCU-159RIGIDRESTRAINT OEVT-3UT95-OEEXPANDED'OR NCR94-124.
VT-3:OESERVICEINDUCEDREJDEFORMATION N.ATTACHUPPERBOLT,LOWERBOLTPULLEDOUT.NCR94-125 GENERATED.
VT-3:RE-EXAMREJ:S.PLATELIFTED5/32".UT:AUG.EXAM.,4BOLTS6"LONG.USE-AS-IS PERREV.NCR94-125.
500790D-BD2.40CCU-160(IA)INTEGRALATTACHMENT OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
OWNERELECTEDEXPANDEDEXAMFORNCR94-124.
31 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.tC5.COMP.COOL.PMPS.,
SUC.FMRES.HT.EX.
&SG.TK(Cont.)SummaryExamNumberCateg500795F-AItemNumberComponent F1.30VCCU-160VARIABLESPRING(IA)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
TEMP.=69DEG.F.,SETTING=5/8"=1832f'SOWNERELECTEDEXPANDEDEXAMFORNCR94-124.
500800F-AF1.30VCCU-165VARIABLESPRINGOEVT-3VT-395-EXPANDED FORNCR94-125.
VT-3:OWNERELECTEDSERVICEZNDUCEDREJECT,LOOSENUTTURNS<1/8TURN.NCR94-129 GENERATED.
VT-3:RE-EXAM,NORECORDABLE INDICATIONS ACCEPTABLE.
500810F-AF1.30RCCU-166RIGIDRESTRAINT OEVT-3VT-395-EXPANDED FORNCR94-125.
VT-3:OWNERELECTEDSERVICEINDUCEDREJECT:LOOSEBOLT,4NUTSLOOSEONHZLTIBOLTS.PLATEAWAYFROMWALL1/8",THRDRODNOTININSPECTION PORTBY1/2"fTHRDSDAMAGE.NCR94-130 GEN.VT-3:RE-EXAM,-NORECORDABLE INDICATIONS.
500820D-BD2.40CCU-167(IA)INTEGRALATTACHMENT OEVT-3VT-395-OWNERELECTEDEXPANDEDFOR'CR94-124 VT-3:ORIGINALCONSTRUCTION REJ:ITEMg8WELDMISSINGOVERPIPETOELBOWWELD.ESIDE1/2",WSIDE5/8".NCR94-131 GENERATED.
VT-3:RE-EXAM,INSIG:LIGHTTOMODERATERUST.USE-AS-ZS PERNCR94-131.
32
RE~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6Co.mmercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.CS.COMP.COOL.PMPS.,SUC.FM RES.HT.EX.&
SG.TK(Cont.)SummaryExamNumberCateg500825F-AItemNumberComponent F1.30VCCU-167VARZABLESPRING(IA)Component TypeOENDEExamVT-3VT-395-EXPANDED FORNCR94-124.
VT-3!OWNERELECTEDEXPANSION SERVICEINDUCEDREJ:SETTINGOUTOFWORKINGRANGET/C002594GENERATED.
VT-3:RE-EXAMAFTERRESETTING, NORECORDABLE INDICATIONS, TEMP.73DEG.F.,SETTING13/32"29481'S-ACCEPTABLE.
F1.30RCCU-168GUIDEOEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE OWNERELECTEDEXPANDEDEXAMFORNCR94-129
&NCR94-130-500840D-BD2.40CCU-169(IA)INTEGRALATTACHMENT OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
INSIG:MODERATERUST-ACCEPTABLE.
OWNERELECTEDEXPANDEDEXAMFORNCR94-124.
500845F-AF1.30VCCU-169OEVARIABLESPRING(IA)95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
TEMP.69DEGF.fSETTING7/8"=2013g'S.OWNERELECTEDEXPANDEDEXAMFORNCR94-124 VT-3500850D-BD2.20CCU-170(IA)INTEGRALATTACHMENT OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129
&NCR-130.VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
I33
ReE.GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceData~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.C5.COMP.COOL.PMPS.,SUC.FM RES.HT.EX.&
SG.TK(Cont.)SummaryExamNumberCateg500855F-AItemNumberComponent F1.30RCCU-170GUIDE(IA)Component TypeOENDEExamVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129
&NCR94-130.
VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE C6.AUX.COOL.
IN&OUTFORBORICACIDEVAPOReDRAWINGS!
C-7SummaryExamNumberCateg500910D-BItemNumberComponent D220CCU-128(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE INSIGLIGHTTOMODERATERUST.NOSPECIFICATIONS FORWELDREINFORCEMENT, INTEGRALATTACHMENT ABANDONED INPLACEACCEPTABLE 500915F-AF1.30RCCU-128GUIDE(IA)OEVT-395-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
501000F-AF1.30RCCU-161GUIDEOEVT-395-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
OWNERELECTEDEXPANDEDEXAMFORNCR94-129
&NCR94-130.
501010F-AF1.30RCCU-162RIGIDRESTRAINT OEVT-395-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
OWNERELECTEDEXPANDEDEXAMFORNCR94-129
&NCR94-130.
ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial BecviceDate~cul197DB.National BoardNumberforUnitNjaATTACHMENT ICLASS3COMPONENTS CONT~C6.AUX.COOL.
IN&OUTFORBORICACIDEVAPOR.(Cont.)SummaryExamNumberCateg501030D-BItemNumberComponent D2.20CCU-164(IA)INTEGRALATTACHMENT NDEComponent TypeExamASME95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
501035F-AF1.30ACCU-164ANCHOR(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
C7~AUX~COOLWTRFROMPEN124f125f126Et130DRAWINGS:
C-5SummaryExamNumberCateg501140F-AItemNumberComponent F1.30RCCU-231RIGIDHANGERComponent TypeOENDEExamVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 6NCR94-130.
VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
501150F-AF1.30RCCU-232RIGIDRESTRAINT OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 6NCR94-130.
VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
501160F-AF1.30RCCU-233RIGIDRESTRAINT OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-129 6NCR94-130.
VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
35 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.C8.SWCOMP.COOLeRSP.FUELPITHTEXSesDZSCH DRAWINGS:"
C-11SummaryExamNumberCateg501660D-CItemNumberD3.20Component Component TypeSWU-164(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE 501665F-AF1.30RSWU-164OERIGIDHANGER(IA)95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
VT-3C9~SVC.WTR~-TOCOMP~COOL~&SP.FL.PIT HT.EX'RAWINGS iC-12SummaryExamNumberCategItemNumberComponent Component TypeNDEExam501870D-CD3.20SWU-191(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3tNORECORDABLE INDICATIONS 6INSIGNIFICANT; MODERATERUSTONPIPE-ACCEPTABLE.
501875F-'AF1.30RSWU-191OERIGIDSUPPORT(IA)95-VT-3:NORECORDABLE INDICATIONS 6INSIGNIFICANT MODERATERUST.DRAWINGDOESNOTMATCHSUPPORTITEMSfl6f5.OLDEcCUT-OFFLUGSREMAIN,DCRGENERATED
-ACCEPTABLE VT-3501890D-CD3.20SWU-193(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
36 R.E~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6C.ommercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONTC9.SVC.WTR.-TO COMP.COOL.&SP.FL.PIT HT.EXS.(Cont.)SummaryExamNumberCateg501895F-AZtemNumberComponent Fl.30RSWU-193RIGIDHANGER(ZA)Component TypeOENDEExamVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE C10.SVC.WTR.-TO A&BDIESELGENeWTReCOOLERS DRAWINGS:
C-13SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam502270D-BD2.20SWU-251(IA)ASMEVT-3INTEGRALATTACHMENT 95-VT-3!NORECORDABLE INDICATIONS
&INSIGNIFICANTS LIGHTRUSTONTHEINTEGRALATTACHMENT
-ACCEPTABLE.
502275F-AF1.30RSWU-251RIGIDSUPPORT(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
&INSIGNIFICANT ITEMg2BASEPLATEISCOVEREDWITHAHEAVYCOATOFPAINTANDCANNOTBESEEN-ACCEPTABLE.
ClioSVC.WTR.-INTMD.BLDG.16"HD.TO PEN312-320DRAWINGS:
C-16BSummaryExamNumberCateg502960D-B95-VT-3:NOItemNumberComponent NDEComponent TypeExamVT-3D2.20SWU-340(IA)ASMEINTEGRALATTACHMENT RECORDABLE INDICATIONS
-ACCEPTABLE.
502965F-AF1.30RSWU-340OERIGIDHANGER(IA)f95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:ITEMf3FILLETWELDTOBEAM=3/16".ITEMill,4SEPARATEFILLETWELDSAREACCORDING TODRAWING.VT-337 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503.LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul197C6.National NoavdNumberforUnitjNAATTACHMENT ICLASS3COMPONENTS CONT.C12~SVC.WTR.-INTMD.BLDG.14"HD.TO CHILL.ASBDRAWINGS:
C-16BSummaryExamNumberCateg503000D-BItemNumberComponent D2.20SWU-344(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
503005F-AFl.30RSWU-344RIGIDRESTRAINT (IA)ASMEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE COLS/NC13~SVCeWTR~PUMPSAfBfC6DDISCH~SCR~HOUSEDRAWINGS'-17 SummaryExamNumberCateg503445F-AItemNumberComponent F1.30RSWU-630(N741)GUIDEComponent TypeOENDEExamVT-395-VT-3:BASELINEEXAMFOREWR5284BV4604REPLACEMENT.
NORECORDABLE EcINSIGNIFICANTf IMPROPERCLEARANCEf NOGAPfACCEPTABLE PERME-121-ACCEPTABLE.
503480D-BD2.20SWU-634(N745)(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3:BASELINEEXAMFOREWR5284BV4604REPLACEMENT.
NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:ADDITIONAL EXAMINATIONS PERFORMED INCLUDEDVT-16MT-ACCEPTABLE 503485F-AF1.30RSWU-634(N745)RIGIDSUPPORT(IA)ASMEVT-395-VT-3:BASELINEEXAMFOREWR5284BV4604REPLACEMENT.
NORECORDABLE 6INSIGNIFICANTf ANCHORBOLTSACCEPTABLE PERNOTEONDRAWING-ACCEPTABLE.
38
R.E.GINNANUCLEARPOWERPLANT/Znservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial BerviceDate~cul19706.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONTC14~AUX~FWPUMPSDZSCH-INTERMED~BLDG,DRAWINGS:
C-1FSummaryExamNumberCategItemNumberComponent NDEComponent TypeExam505060F-AF1.30RAFU-14RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:NOIDTAGONSTRUT.505080F-AF1.30RAFU-16RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3$NORECORDABLE INDICATIONS
-ACCEPTABLE.
CGLS/NN633N-EG-13312-81-377H.
505110F-AF1.30RAFU-19RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
C&LN-EG-13312-81-3771.
505120F-AF1.30RAFU-20RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
505170F-AF1.30RAFU-25U-BOLT(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
505180F-AF1.30RAFU-26OERIGIDHANGER(NRC50%)95-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
VT-339
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6.Commercial ServiceDate~Jul19706.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.C14.-AUX.FWPUMPSDISCH-ZNTERMED.
BLDG.(Cont.)SummaryExamNumberCateg505190F-AItemNumberComponent F1.30RAFU-27RIGIDRESTRAINT Component TypeOENDEExamVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-121.
VT-3sNORECORDABLE INDICATIONS 6ZNSZGNZFZCANTf FILLETWELDSTOEXISTING12WF53ARE5/16"-ACCEPTABLE.
505200F-AF1.30RAFU-28OERIGIDHANGER(NRC50%)95-VT-3:OWNERELECTEDEXAMREJ:PIPESUPPORTHASAPPROXIMATELY 1/2"PLAY6ISFREETOMOYENNOTSERVICEINDUCED.NCR94-121 GENERATED.
VT-3:RE-EXAMfNORECORDABLE INDICATIONS
-ACCEPTABLE.
VT-3VT-3505210F-AF1.30RAFU-29GUIDE(NRC50%)OEVT-395-OWNERELECTEDEXPANDEDEXAMFORNCR94-121 VT-3:NORECORDABLE INDICATIONS 6ZNSZGNZFZCANTf 1/4"FILLETWELDSWERE>1/4<5/1663/16FILLETWELDSWERE>3/16<1/45/16"FILLETWELDSWERE>5/16"<3/8"-ACCEPTABLE 505230D-BD2.20AFU-100(ZA)INTEGRALATTACHMENT 95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE VT-3505235F-AF1.30RAFU-100GUIDE(ZA)OEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE OTHER:ALLSHIMSNOTEDAREINADDITIONTODRAWINGS.
THE7/8"SHZMSHAVE'/16"FILLERWELDSANDTHE1/4"SHIMHASA1/8"FILLETWELDSHIMSPECIFICATIONS AREUNKNOWN.40
RaE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~sC14.AUX.FWPUMPSDISCH-INTERMED.
BLDG.(Cont.)SummaryExamNumberCateg505360F-AItemNumberComponent F1.30RAFU-38GUIDE(NRC50%)Component TypeOENDEExamVT-395-VT-3NORECORDABLE INDICATIONS 6INSIGNIFICANTS SHIMUSEDONBOTTOMOFPIPE6ISWELDEDTOITEMP2-ACCEPTABLE 505370F-AF1.30RAFU-39GUIDE(NRC50%)OEVT-3BDS95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
410F-AF1.30RAFU-43RIGIDRESTRAINT (NRC50%)95-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
CGLS/N633,N-EG-13312-81-377J.
VT-3505520F-AF1.30RAFU-54RIGIDRESTRAINT (NRC50't)OEVT-395-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
S/NN6336N-EG-13312-81-348-33.
505560F-AF1.30RAFU-106GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
505580D-BD2.40AFU-108(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE ReEeGINNANUCLEARPOWERPLANTInservtce Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY14593.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197C6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~C14.AUX.FWPUMPSDISCH-INTERMED.
BLDG.(Cont.)SummaryExamNumberCategItemNumberComponent Component TypeNDEExam505585F-AF1.30VAFU-108VARIABLESPRING(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
TEMP.136DEG.F,SETTING=1.45=104g'SC<YPEBSIZElfID/N-EG-13312-82-296.
C15~TURBAUXFWPUMPDISCHARGE DRAWINGS:
C-1eSummaryExamNumberCateg505612F-AItemNumberComponent F1.30RAFU-87GUIDE(NRC50%)Component TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
C16~AUX'WPUMPSDISCH-INTERMED~BLDG'RAWINGS:
C-1SummaryExamNumberCateg505640F-AZtemNumberComponent F1.30RAFU-64GUIDE(NRC50't)OEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:DISTANCEBETWEENPIPE&GUIDE-NORTHSIDE=0"fSOUTH,EAST&WEST<1/16"&NOT0".505680F-AF1.30RAFU-68RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
C&LS/N6339N-EG-13312-91-348-40.
42 RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~tC16.AUX.FWPUMPSDISCH>>INTERMED.
BLDG.(Cont.)Summary.ExamNumberCategItemNumberComponent Component TypeExam505690F-AF1.30RAFU-69GUIDE(NRC50t)OE95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:DISTANCEBETWEENPIPE&GUIDEISASFOLLOWSNORTHSIDE1/8",SOUTHSIDE=OmsEAST6WESTSIDES=1/16".505710F-AF1.30RAFU-71OERIGIDRESTRAINT (NRC50%)~95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
VT-3505760F-AF1.30VAFU-76VARIABLESPRING(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
TEMP.84DEG.F.,SETTING0.85=2451'S.IDNEG1331282306B,TYPEB.505840D-BD2.20AFU-93(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
505845F-AF1.30RAFU-93GUIDE(IA)OEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
OTHER:ALLSHIMSNOTEDAREINADDITIONTODRAWINGS, THE7/8"SHIMSHAVE3/16"FILLETWELDSANDTHE1/4"SHIMHASA1/8"FILLETWELD.SHIMSPECIFICATIONS AREUNKNOWN.
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT~sC16.AUX.FWPUMPSDISCH-INTERMED.
BLDG.(Cont.)SummaryNumber505940ExamItemCategNumberComponent F-AF1.30RAFU-85GUIDE(NRC50%)NDEComponent TypeExamOEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE NOTE:LIMITATION, GROUTCONCEALING PARTOFCOLUMNTOBEAMWELD506040F-AF1.30RAFU-120RIGIDRESTRAINT (NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
S/NN663.IDPN-EG-13312-81-345-8.
C17~STANDBYAUXFWFRMPEN119AUXFWPUMPCDRAWINGS:
C-21SummaryExamNumberCategItemNumberComponent Component TypeNDEExam507240F-AF1.30RAFU-261(AFW-74)OEU-BOLT(NRC50%)VT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
507250F-AF1.30RAFU-262(AFW-75)U-BOLT(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
507290F-AF1.30RAFU-266(AFW-79)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
507350F-AF1.30RAFU-272(AFW-85)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
ReE~GINNANUCLEARPOWERPLANTInservice Znspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DB.National BoardNumberforUnitN~AATTACHMENT ICLASS3COMPONENTS CONT~C17.STANDBYAUXFWFRMPEN119-AUXFWPUMPC(Cont.)SummaryExamNumberCateg507390F-AItemNumberComponent F1.30RAFU-164(AFW-89)GUIDE(NRC50%,)OEVT-3NDEComponent TypeExam95-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
507445F-AF1.30RAFU-153(AFW-120)
GUIDE(NRC50%)OEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE 507500F-AF1.30RAFU-159(AFW-98)GUIDE(NRC50%)OEVT-395-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:SHIMPLATEBETWEENITEMgl6ZTEMf2ZSTACKED.507520F-AF1.30RAFU-158(AFW-100)
GUIDE(NRC50%)OEVT-395-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
507560F-AF1.30RAFU-196(AFW-104)
GUIDE(NRC50t)OEVT-395-VT-3$NORECORDABLE INDICATIONS
-ACCEPTABLE.
45 ReE~GZNNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (ZfRec[.)~NAS.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONTtC18.STANDBYAUXFWFRMPEN123-AUXFWPUMPDDRAWINGS'-25 SummaryNumberExamCateg508145F-AZtemNumberComponent F1.30RAFU-231(AFW-51)GUIDE(IA)NDEComponent TypeExamVT-3OE95-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE BASELINEEXAMPERFORMED AFTERRE-INSTALLATION OFSUPPORT,NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:DAMAGEIDENTIFIED ONPIPEADJACENTSUPPORTSNCR95025GENERATEDS AREACONDITIONED, SEEPACKAGE.508146D-BD2.20AFU-231(AFW-51)(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
508147F-AF1.30RAFU-232(NEW)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
INSIG:NOSHIMITEMS4-ACCEPTABLE.
508150F-AF1.30RAFU-234(NEW)U-BOLT(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
CGLIDN-EG-13312-81-377N.
508170F-AF1.30RAFU-237(AFW-55)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
508260.F-AF1.30RAFU-246(AFW-64)GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCerti.ficate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.tC18.STANDBYAUXFWFRMPEN123-AUXFWPUMPD(Cont.)SummaryExamNumberCateg508330F-AItemNumberComponent Fl30RAFU-253(AFW-71)RIGIDHANGER(NRC50't)OEVT-3NDEComponent TypeExam95-VT-3sNORECORDABLE INDICATIONS
-ACCEPTABLE.
508360F-AF1.30RAFU-179(AFW-119)
GUIDE(NRC50'4)OEVT-395-VT-3sNORECORDABLE INDICATIONS
-ACCEPTABLE OTHER:NOTETOLERANCES BETWEENPIPEANDSUPPORT[SETTINGS PERDRAWINGIN()]NORTH0(1/8)6EAST1/8(1/16)6SOUTH3/16(0)6WEST0(1/32)~508390F-AF1.30RAFU-182(AFW-112)
GUIDE(NRC50IL)OE95-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE OTHER:NOTE,NOSHIMPLATEITEMg9.508435F-AF1.30RAFU-187(AFW-121)
GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE 508450F-AF1.30RAFU-189('AFW-106)
GUIDE(NRC50%)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE OTHER:NOTE,ITEMf7SHIMPLATEHASFULLLENGTHFILLETWELD,NOTTACKWELD.47 0
ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)'%~A B.commercial ServiceDate~Jul197D6.National BoardNumtecforUnitjNAATTACHMENT ICLASS3COMPONENTS CONTsC19~TURBINEDRIVENAUX~FWPUMPSUCTIONDRAWINGS:
C-16SummaryExamNumberCategItemNumberComponent Component TypeNDEExam508500F-AF1.30RAFU-1OERIGIDRESTRAINT (NRC50%)VT-395-VT-3!NORECORDABLE INDICATIONS
&INSIGNIFICANTf PAINTISSTARTINGTOBLISTERDUETOLIGHTCORROSION ONITEMSP4&PS-ACCEPTABLE C&LID'SN-EG-13312-82-311-I, N-EG-13312-82-311-J.
508510F-AF1.30RAFU-2OERIGIDRESTRAINT (NRC50t)95-VT-3:NORECORDABLE INDICATIONS
&OTHERf4"LINEHAS2WELDEDLUGSAT0&180DEG.TORIGIDRESTRAINT.
S/NN633,N-EG-13312-81-348-2
-ACCEPTABLE.
VT-3C20.SWSUPPLYTOSAFWPUMPCDRAWINGS!
C-28SummaryExamNumberCategItemNumberComponent Component TypeNDEExam508815D-BD2.20SWU-590(SW-122)(IA)ASMEINTEGRALATTACHMENT VT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
508817F-AF1.30RSWU-590(SW-122)GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
R.E.GINNANUCLEARPOWERPLANTaInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul199DB.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.tC21~MOTORDRIVENAUX,FWPUMPSUCTIONDRAWINGS:
C-33SummaryExamNumberCateg508600F-AItemNumberF1.30RComponent SWU-284RIGIDRESTRAINT 50%)Component TypeExamOEVT-3(NRC95-VT-3!NORECORDABLE INDICATIONS
-ACCEPTABLE.
NOTE:CGLfN-EG-13312-81-178B, NOSIZELABELED'22.
SWSUPPLYTOSAFWPUMPDDRAWINGS:
C-28SummaryExamNumberCateg508930D-BItemNumberD2.20Component SWU-514(SW-142)(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
508933F-AF1.30RSWU-514(SW-142)GUIDE(IA)ASMEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
OTHERITEMP2ANGLEISINCONTACTWITHCONDUITATWALL.USE-AS-IS PERENGINEERING.
C23~STANDBYAUX.FW,SWSUPPLYTOSAFWPUMPDDRAWINGS:
C-28SummaryNumberExamCateg508960F-AItemNumberComponent F1.30RSWU-522(SW-140)GUIDEComponent TypeOENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPer'iod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6C.ommercial ServiceDate~Jul197CS.National BoardNumberforUnit~NAATTACHMENT I.CLASS3COMPONENTS CONT.tC24~MAINSTEAMSUPPLYTOAUXFWPUMPTURBINEDRAWINGS'-32 SummaryExamNumberCateg509020D-BItemNumberD2.20Component Component TypeMSU-64(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3!NORECORDABLES INSIGNIFICANT 6OTHERSTOPLUGBENT5DEG'.f3/16"CLEARANCE, SOUTHLUG1.8"CLEARANCE.
BOTTOMTIGHTTOg7fNORTHTIGHTTOg5.DCRGENERATED TOUPDATEDRAWINGFOR2ADDITIONAL LUGS-ACCEPTABLE 509025F-AF1.30RMSU-64RIGIDRESTRAINT (IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE C25.MAINSTEAMLOOPATOAUXFWPUMPTURBINEDRAWINGS:
C-32SummaryNumberExamCategItemNumberComponent Component TypeNDEExam509160D-BD2.30MSU-78(IA)INTEGRALATTACHMENT ASMEVT-395-VT-3:TEMP.76DEG.'F.;SETTING31/8".NORECORDABLE INDICATIONS
-ACCEPTABLE.
509165F-AF1.308MSU-78MECHANICAL SNUBBER(IA)OEVT-395-VT-3:TEMP.76DEG.F.fSETTING31/8",NORECORDABLE INDICATIONS
-ACCEPTABLE.
50
ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report,1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Ju11970S.National BoardNumberforUnit~NAATTACHMENT ICLASS3COMPONENTS CONT.!C26eAUXFWPUMPAFLOWCONTROLBYPASSDRAWINGS:
C-1GSummaryExamNumberCateg510035D-BItemNumberComponent Component TypeD2.20AFU-60(IA)ASMEINTEGRALATTACHMENT NDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
510040F-AF1.30RAFU-60GUIDE(IA)OEVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
C27.AUXFWPUMPBFLOWCONTROLBYPASSDRAWINGS:
C-1HSummaryExamNumberCateg510065D-BItemNumberComponent D2.20AFU-128(IA)INTEGRALATTACHMENT Component TypeASMENDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
510070F-AF1.30RAFU-128GUIDE(IA)OEVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
51
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6~Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NBATTACHMENT ID.HIGHENERGYCOMPONENTS tDl>>MAINSTEAMLOOPAOUTSIDECVDRAWINGStB-9ASummaryExamNumberCategItemNumberComponent Component TypeExam200020HE-DBLlREDUCER-TO-TEE AUGVT-1MTRT95-VT-1&MT:NORECORDABLE INDICATIONS.
RT:NORECORDABLE
&INSIGNIFICANTS POROSITY&SLAG.NOAPPARENTCHANGESINCELASTEXAMINATION
-ACCEPTABLE D2~MAINSTEAMOUTSIDECVDRAWINGS:
HE-7tSummaryNumberExamCategItemNumberComponent Component TypeNDEExam200025HE-DBL2TEE-TO-PIPE AUGVT-1MTRT95-VT-1&MT:NORECORDABLE INDICATIONS
-ACCEPTABLE-RT-NORECORDABLE
&INSIGNIFICANTS SLAGSPOROSITYS WASHOUTSNOCHANGESINCELASTEXAMINATION
-ACCEPTABLE D3~MAINSTEAMLOOPBOUTSIDECVDRAWINGS:
B-10SummaryExamNumberCategItemNumberComponent Component TypeExam200045HE-DBPlREDUCER-TO-TEE AUGVT-1RTMT95-MT:NORECORDABLE, LIM:L=23"-35" DUETOSUPPORT90t.VT-1:NORECORDABLE
&INSIGNIFICANT L=561/2",W=ll1/2"UP,2INDICATIONS FROMLINEUPLUG-1/8X21/2X1/64.RT:NORECORDABLE
&INSIGSPOROSITYS PEENMARKSSWASHOUTSNOCHANGE-ACCEPTABLE.
a52 R.E.GINNANUCLEARPOWERPLANT/Inservice Inspection Report1990-1999
- Interval, S'econdPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IHIGHENERGYCOMPONENTS CONTD4,FEEDWATER TURBINEBUILDINGDRAWINGS:
HE-6SummaryNumberExamCategItemNumberComponent Component TypeNDEExam200050HE-DBM3PIPE-TO-TEE AUGVT-1UTMT95-VT-1&MT:NORECORDABLE INDICATIONS.
UT:NORECORDABLE
&GEOMETRYS COUNTERBORE, CROWN&ROOTGEOMETRY.
ZERODEGREESCANPERFORMED IN'92.,>90%COVERAGE-ACCEPTABLE.
D5~FEEDWATER LOOPAOUTSIDECVDRAWINGSHE-5SummaryExamNumberCategItemNumberComponent Component TypeExam200055HE-DBM4TEE-TO-REDUCER AUGVT-1~UTMT95-VT-1&MT;NORECORDABLE INDICATIONS.
UTNORECORDABLE
&GEOMETRYS COUNTERBORE
&ROOTGEOMETRY,
>90'tCOVERAGEACCEPTABLE.'6.
FEEDWATER LOOPBOUTSIDECVDRAWINGS'E-5 SummaryExamNumberCateg200075HE-DBItemNumberComponent AlTEE-TO-REDUCER Component TypeAUGNDEExamVT-1UTMT95-VT-1&MT:NORECORDABLE INDICATIONS.
UTsNORECORDABLE, INSIGNIFICANT
&GEOMETRYS COUNTERBORE
&SLAGINCLUSION, 90'tCOVERAGEACHIEVED-ACCEPTABLE.
53 RaE~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IHIGHENERGYCOMPONENTS CONTD7eMAINSTEAMLOOPAOUTSIDECVDRAWINGS:
B-9ASummaryExamNumberCategItemNumberComponent NDEComponent TypeExam200160HE-CBL3519VALVE-TO-REDUCER AUGVT-1RTMT95-VT-1&MT:NORECORDABLE INDICATIONS.
RT:NORECORDABLES" INSIGNIFICANT
&OTHERGOUGEINBASEMETALAT71"fPOROSITYNOCHANGESINCELASTEXAM-ACCEPTABLE.
D8~MAINSTEAMLOOPBOUTSIDECVDRAWINGS:
B-10SummaryExamItemNumberCategNumberComponent NDEComponent Type~Exam200220HE-CBP3518VALVE-TO-REDUCER AUGVT-1RTMT95-MT:NORECORDABLE INDICATIONS.
VT-1:NORECORDABLE
&INSIGNIFICANTS LINE-UPLUG.RT:NORECORDABLE
&6INSIGNIFICANT;
- POROSITY, SLAG,BASEMETALINDICATION WHERETEMPORARY ATTACHMENT LOCATED944".NOCHANGESINCELASTEXAM-ACCEPTABLE.
D9~MAINSTEAMTURBINEBUILDINGDRAWINGS:
HE-7ASummaryExamNumberCategItemNumberComponent NDEComponent TypeExam200280HE-CBClELBOW-TO-PIPE AUGVT-1UTMT95-MT:NORECORDABLE.
VT-1:INSZGNIFZCANT; MINORPITTZNGONPIPE<1/32~UTNORECORDABLE
&GEOMETRYs ROOTSCOUNTERBORE, WELDCROWNGEOMETRY/REDIRECTED BEAM.>90%COVERAGEOBTAINED-ACCEPTABLE.
54 IO R.E.GINNANUCLEARPOWERPLANTInservice Inspection.
Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IHIGHENERGYCOMPONENTS CONT.D9.MAINSTEAMTURBINEBUILDING(Cont.)SummaryExamNumberCateg200285HE-CBItemNumberComponent DPIPE-TO-ELBOW Component TypeAUGNDEExamVT-1UTMT95-MT:NORECORDABLE.
VT-1:INSIGNIFICANT MINORPITTING1/32ONPIPE~UTNORECORDABLE 9GEOMETRY6OTHERSROOTSCOUNTERBORE 9WELDCROWN5MODECONVERSION56SLAGINCLUSION
~90%COVERAGE-ACCEPTABLE.
200320HE-CBM2ELBOW-TO-PIPE D10.FEEDWATER TURBINEBUILDINGSummaryExamItemNumberCategNumberComponent DRAWINGS:
HE-6AUGNDEComponent TypeExamVT-1UTMT95-VT-16MT:,NORECORDABLE INDICATIONS.
UT:NORECORDABLES GEOMETRY6OTHERS'ROWN 6(ROOTGEOMETRY, COUNTERBORE 6MODECONVERSION
-COUNTERBORE,
)90'tCOVERAGEACHIEVEDACCEPTABLE.
DllaFEEDWATER LOOPAOUTSIDECVDRAWINGS:
B-11SummaryExamItemNumberCategNumber200455HE-CBComponent Z3PIPE-TO-ELBOW Component TypeAUGNDEExamVT-1RTMT95-VT-1,MT6RT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
55 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89Eastve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul197CS.National BoardNumberforUnit~NA.ATTACHMENT IHIGHENERGYCOMPONENTS CONT.tDll.FEEDWATER LOOPAOUTSIDECV(Cont.)SummaryExamNumberCateg200460HE-CBItemNumberComponent Z4ELBOW-TO-PIPE Component TypeAUGNDEExamVT-1UTMT95-VT-16MT:NORECORDABLE INDICATIONS.
UTsNORECORDABLE GEOMETRY:
ROOT,COUNTERBORE, ROUGHROOT,SPOTINDICATION ATWELDCROWN,)90'tCOVERAGE-ACCEPTABLE NumberCategNumber200575HE-CBComponent OlELBOW-TO-PIPE D12.FEEDWATER LOOPBOUTSIDECVSummaryExamItemComponent TypeAUGDRAWINGS:
B-14NDEExamVT-1RTMT95-VT-l,MT6fRT:NORECORDABLE INDICATIONS
-ACCEPTABLE.
200580HE-CB----PPIPE-TO-ELBOW AUGVT-1RTMT95-MT:NORECORDABLE INDICATIONS.
VT-1NORECORDABLE 6fZNSZGNZFZCANTS MINORCORROSION.
RT:NORECORDABLE 6ZNSZGNZFZCANTS POROSITY&SLAG,NOAPPARENTCHANGESINCELASTEXAMINATION
-ACCEPTABLE.
56
R.E~GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA6Co.mmercial ServiceDate~Jul197CS.National BoardNumberforUnitN~AATTACHMENT IHIGHENERGYCOMPONENTS CONT~D13~MAINSTEAMTURBINEBUILDINGDRAWINGS:
HE-7ASummaryExamNumberCategItemNumberComponent Component TypeNDEExam201420HE-CS*F1.20VMS-45(S21)VARIABLESPRINGOEVT-395-VT-3:TEMP.68DEG.F.,SETTING1/2"=4825if'SsNORECORDABLE INDICATIONS
-ACCEPTABLE.
- BASELINE, REMOVEDFORACCESSOFHEWELDC1.201440HE-CS*F1.20VMS-46(S22)VARIABLESPRING(IA)OEVT-395VT3TEMP~71DEG~F~sSETTING1/2fVS2SIZE176NORECORDABLE INDICATIONS
-ACCEPTABLE.
- BASELINE, REMOVEFORACCESSOFHEWELDD.201441HE-IA*C3.20MS-46(S22)(ZA)INTEGRALATTACHMENT OEMT95-MT:NORECORDABLE INDICATIONS INLIMITEDEXAM.71/2"OFWELDINBETWEENZA(BOTHSIDE)NOTACCESSIBLE FORMTVISUALPERFORMED APPROX90%INSPECTED
-ACCEPTABLE.
D14.FEEDWATER LOOPBOUTSIDECVDRAWINGSe B-14SummaryExamNumberCateg201860HE-CSItemNumberComponent
- F1.20SFWU-38MECHANICAL SNUBBERComponent TypeOENDEExamVT-395-VT-3:BASELINEEXAMAFTERRE-INSTALLATION TEMP.68DEG.F.fSETTING31/2".NORECORDABLE INDICATIONS
-ACCEPTABLE.
57 ReEeGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul197DB.National BoardNumberforUnit~NAATTACHMENT IE.LEAKAGETESTINGE1~LEAKAGEEXAMINATIONS CLASS1f2f3SummaryExamNumberCateg411000B-PItemNumberComponent IWB5221PT-7LEAKAGETESTOFREACTORCOOLANTSYSTEMASMEVT-2NDEComponent TypeExam95-VT-2:TESTSATISFACTORYf DEFICIENCIES CORRECTED DURINGTESTgSEEEXAMSHEETFORDETAILS-ACCEPTABLE.
411400HE-LK---MSHIGHENERGYAUG95-VT-2:NORECORDABLE INDICATIONS, ACCEPTABLE.
t411600C-HIWC5221FWOUTSIDECONTAINMENT ASME95-VT-2:NORECORDABLE INDICATIONS
-TESTACCEPTABLE.
VT-2411700D-BIWD5221AUXFW"A"PUMPASMEVT-295-VT-2:NORECORDABLE INDICATIONS, ACCEPTABLE.
412100D-BIWD5221STANDBYAUXILIARY FEEDWATER PUMP"D"ASMEVT-295-VT-29NORECORDABLE
&INSIGNIFICANT PACKINGLEAKONV9708B&V9704B.GASKETLEAKBETWEENV9714B&V9715B.COMPLETETESTPERFORMED IN2PARTS-TESTSATISFACTORY.
412500C-HIWC5221SAFETYINJECTION "A"ASMEPUMPIN/OUTCONTAINMENT VT-295-VT-2:NORECORDABLE
&OTHER)BORICACIDRESIDUEONVALVES828A,828B&12400.PACKING/STEM DRY.FLANGEATFE-294ATINTERFACE, RANDOM360DEGREES-TOBEDECONNED&CHECKEDONPT-8.8.TESTSATISFACTORY.
58 R.E.GINNANUCLEARPOWERPLANTZnservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ILEAKAGETESTING.CONT.El.LEAKAGEEXAMINATIONS CLASS1,2,3(Cont.)SummaryExamNumberCateg413000C-HItemNumberComponent IWC5221CONTAINMENT SPRAYAPUMPDISCHARGE Component TypeASMENDEExamVT-295-VT-2:NORECORDABLE 6INSIGNIFICANTs DRIEDBORICACIDONV831AsV857BsV857CSV893A&V893B~PACKINGLEAK6DRYBORICACIDRESIDUEONV862A.BODYTOBONNETHASBORICACIDRESIDUEATBOTTOMOFJOINT.ACCEPTABLE.
413100C-HIWC5221CONTAINMENT SPRAYBPUMPDISCHARGE ASMEVT-295-VT-2:NORECORDABLE 6INSIGNZFICANT PACKINGLEAKBORICACIDRESIDUEONV860C6V869A.SWAGE-LOK TEEUPSTREAMOFLT-921HASBORICACIDRESIDUE.ACCEPTABLE.
413150C-HIWC5221SPRAYADDITIVENOAHTANKASMEVT-295-VT-2:NORECORDABLE INDICATIONS, ACCEPTABLE 413600D-BIWD5221AUXCOOLINGINSIDEASMECONTAINMENT VT-295-VT-2:NORECORDABLE 6INSIGNIFICANT V754BHASPACKINGDRYRESIDUE.ACCEPTABLE.
413700D-BIWD5221AUXCOOLINGOUTSIDEASMECONTAINMENT VT-295-VT-2:-TESTSATISFACTORY, SEEEXAMSHEETFORDETAILS.NOTE:WASTEEVAPORATOR
- ISOLATED, NOTBEINGUSED.ACCEPTABLE.
59 eR.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ILEAKAGETESTINGCONT~tEl.LEAKAGEEXAMINATIONS CLASS1,2,3(Cont.)SummaryExamNumberCateg414000D-AItemNumberComponent IWD5221SERVICEWATEROUTSIDECONTAINMENT Component TypeASMENDEExamVT-295-VT-2NORECORDABLE 6INSIGNIFICANT "A"LOOPBURIEDPIPEEXAMINEDUSINGIDPIPECRAWLER.IDGOODCONDITION-NO LEAKPATHSOBSERVED.
REMOVEDRUSTONPACKINGGLANDONV4627.AEcDSWPUMPBOUNDARIES PERFORMED
-ACCEPT.PARTIALEXAM.414100D-AIWD5221SERVICEWATERTOAUXFWPUMP"A"ASMEVT-295-VT-2tNORECORDABLE INDZCATIONS.
ACCEPTABLE.
414600C-HIWC5221CHARGING6SEALWATERASMEFROMPUMPS(IN/OUTCV)95-VT-2tNORECORDABLE 6INSIGNIFICANTS'ERFORMED DURINGPT7~PACKINGGLANDBORONRESIDUEV281ASV2875V277ASV291V288.BODY-BORON RESIDUEPIC-1836BODYTOBONNETONV357".PACKZNGLEAKONV392B,FIXEDDURINGTEST.ALLDECONNED-WILL BERECHECKED.
VT-2415500D-BIWD5221SPENTFUELPOOLCOOLING-A ASMEVT-295-VT-2tNORECORDABLE
&INSIGNIFICANTS CHECKVALVEV8655HASBODYTOBONNETLEAKWITHBORICACIDRESIDUE.VT-3ONBOLTINGWHENVALVEIDOPENED,WORKREQUESTWRITTENACCEPTABLE 415550D-BIWD5221SPENTFUELPOOLCOOLING-B ASMEVT-295-VT-2tNORECORDABLE 6INSIGNIFICANTS FULLEXAMINATION BOUNDARYHASBEENCOMPLETED, TESTSATISFACTORY.
SEEEXAMINATION RECORDFORDETAILS.60 ReEGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul1979S.National BoardNumberforUnit~NAATTACHMENT IF~SNUBBERPROGRAMCOMPONENTS gFluSTEAMGENERATOR BDRAWINGS:
A-7FSummaryExamNumberCateg600120SN-VTItemNumberComponent SGB-3HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395VT3NORECORDABLE INDICATIONS5TEMP67DEGF5SETTING393/8",S/NAH-2-ACCEPTABLE.
600121SN-FTSGB-3HYDRAULIC SNUBBERAUGFT9P-FT-OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOg19404251.
F2~AUX~FWPUMPSDISCH-INTERMED~BLDG~DRAWINGS:
C-1ESummaryExamNumberCateg600240SN-VTZtemNumberComponent Component TypeAFU-34AUGMECHANICAL SNUBBERNDEExamVT-395-VT-3:TEMP.70DEG.F.,SETTING27/8",S/N14448.NORECORDABLE INDICATIONS
-ACCEPTABLE.
600241SN-FTAFU-34MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
SNUBBERDEGRADEDANDREPLACED.
WOP19404236.
600280SN-VTAFU-75MECHANICAL SNUBBERAUGVT-395-VT-3:TEMP.73DEG.F.,SETTING21/8",S/N20924.NORECORDABLE INDICATIONS
-ACCEPTABLE 61 RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)a1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F2~AUX.FWPUMPSDISCH-INTERMED.
BLDG.(Cont.)SummaryExamNumberCateg600281SN-FTItemNumberComponent AFU-75MECHANICAL SNUBBERNDEComponent TypeExamAUGFT95-FT!OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOP19404237.
600400SN-VTAFU-123MECHANICAL SNUBBERAUGVT-3095VT3TEMP~73DEG~F5SETTING25S/N22485~NORECORDABLE
&INSIGNIFICANTS SNUBBERHASMOVEMENTINBOTHDIRECTIONS
-ACCEPTABLE.
600401SN-FTAFU-123MECHANICAL SNUBBERAUGFT95-FT!OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
SNUBBERDEGRADEDANDREPLACEDWOg19404238.
F3~STEAMGENERATOR BBLOWDOWNLINEDRAWINGS:
B-31SummaryExamNumberCategItemNumberComponent Component TypeNDEExam600460SN-VTBDU-16AUGMECHANICAL SNUBBERVT-395-VT-3!BASELINEEXAMAFTERREINSTALLATION DUETOBLOWDOWNREPLACEMENT.
TEMP.68DEG.F.,SETTING27/BmsS/N10182.SNUBBERINSTALLED 180DEGREESFROMDRAWING,NORECORDABLE INDICATIONS
-ACCEPTABLE.
600461SN-FTBDU-16MECHANICAL SNUBBERAUGFT95-FT!OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WON19404239.
62
R.E~GINNANUCLEARPOWERPLANTZnservice Inspects.on Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197D6.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONTF4.2"CVCSRELIEFLINETOPRTDRAWINGSa B-32SummaryExamNumberCateg600940SN-VTItemNumberComponent CVU-80MECHANICAL SNUBBERAUGVT-3.Component.
TypeExam95VT3TEMP~74DEG~F9SETTING11/2fS/N235189NORECORDABLE INDICATIONS
-ACCEPTABLE 600941SN-FTCVU-80MECHANICAL SNUBBERAUGFT95-FT:OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
REPLACEDSNUBBER-DEGRADED, WOP19404240.
F5~CVCSLETDOWNLINETOMZXBEDDEMZNDRAWINGS:
B-36SummaryExamNumberCateg601080SN-VTItemNumberComponent CVU-372MECHANICAL SNUBBERAUGVT-3NDEComponent TypeExam95VT3TEMP~f69DEGFfSETTING3/49S/N9478~NORECORDABLE INDICATIONS
-ACCEPTABLE.
601081SN-FTCVU-372MECHANICAL SNUBBERAUGFT95-FT:OTHERFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
SNUBBERDEGRADEDANDREPLACED, WOÃ1940424163 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT.F6.FEEDWATER LOOPAINSIDECVDRAWINGS'-12 SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam601110SN-VT---FWU-5AUGVT-3HYDRAULIC SNUBBER95-VT-3:TEMP~69DEG~F~6SETTING1/2EXT3fS/N2500-10-152.
NORECORDABLE INDICATIONS
-ACCEPTABLE.
601111SN-FTFWU-5HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOP19404249.
F7.FEEDWATER LOOPBOUTSIDECVDRAWINGS'-14 SummaryExamNumberCategItemNumberComponent Component TypeNDEExam601270SN-VTFWU-44AUGHYDRAULIC SNUBBERVT-395-VT-3:BASELINEEXAMAFTERREINSTALLATION.
TEMP.72DEGF.,S/NG43864-02-20, SETTING315/16meSPECIFICATION STATES3".NCR95-045 GENERATED, NOTSERVICEINDUCED.DISPOSITIONED USE-AS-IS PERENGINEERING.
NORECORDABLE, OTHER6REJECT-ACCEPTABLE.
601271SN-FTFWU-44HYDRAULIC SNUBBERAUGFT95-FT!OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOI.19404250.
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriodfThirdOutage(1995)1.OwnerRochester Gas67ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial ServiceDate~cul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT.FS~MAINSTEAMLOOPBOUTSIDECVDRAWINGS:
B-10ASummaryExamNumberCateg601390SN-VTItemNumberComponent MSU-12MECHANICAL SNUBBERAUGVT-3NDE'Component TypeExam95-VT-3sTEMP59DEG.F,SETTING31/4",S/N9400.NORECORDABLE INDICATIONS
-ACCEPTABLE.
601391SN-FTMSU-12MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOE19404244.
601429SN-VT----MSU-18(NORTH)MECHANICAL SNUBBERAUGVT-395-VT-3:TEMP59DEGF.,SETTING21/4",S/N7478.NORECORDABLE INDICATIONS
-ACCEPTABLE.
601430SN-VT----MSU-18(SOUTH)MECHANICAL SNUBBERAUGVT-395VT3TEMP~59DEG~FfSETTING21/45S/N7197~NORECORDABLE INDICATIONS
-ACCEPTABLE.
601431SN-FTMSU-18(NORTH)MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOP19404246.
601432SN-FT----MSU-18(SOUTH)MECHANICAL SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBERFAILED.SNUBBERREPLACEDWO19404245.
REQUIREDTOTESTMSU-19NORTHPERNCR95-017, WO19501218.
FUNCTIONAL TESTOFSNUBBER-RETESTIN1996.65 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriodsThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commeccial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~tF8.MAINSTEAMLOOPBOUTSIDECV(Cont.)SummaryExamNumberCateg601439SN-VTItemNumberComponent MSU-19(NORTH)MECHANICAL SNUBBERAUGVT-3NDEComponent TypeExam95-VT-3sBASELINEFORREINSTALLATION, FTEXPANDEDTESTTORESOLVENCR95-017 (MSU-18).
TEMP.55DEG.FfSETTING3"fS/N9369.NORECORDABLE INDICATIONS
-ACCEPTABLE 601441SN-FT----MSU-19(NORTH)MECHANICAL SNUBBERAUGFT95-FT$OTHERFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFMSU-18SOUTH-ACCEPTABLE.
WO195012186NCR95-017.
EXPANDEDEXAM.F9MAINSTEAMLOOPAOUTSIDECVDRAWINGS:
B-9SummaryNumberExamCategItemNumberComponent Component TypeNDEExam601550SN-VTMSU-44MECHANICAL SNUBBERAUGVT-395-VT-3sTEMP.76DEG.F.,SETTING31/2",S/N1468,NORECORDABLE INDICATIONS
-ACCEPTABLE.
601551SN-FTMSU-44MECHANICAL SNUBBERAUGFT95-FTsOTHERSFUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOP19404243.
066 R.E,GINNANUCLEARPOWERPLANTInservice Znspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.Commercial ServiceDate~Jul1976S.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F10eMAINSTEAMLOOPBATMOSPHERIC VENTDRAWINGS:
B-10SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam601570SN-VTMSU-57MECHANICAL SNUBBERAUGVT-395VT3TEMP74DEGFsSETTING31/4sS/N27182'ORECORDABLE INDICATIONS
-ACCEPTABLE.
601571SN-FTMSU-57MECHANICAL SNUBBERAUGFT95-FT:OTHERNTESTFAILED,SNUBBERREPLACEDUNDERWO¹'9404247.
REQUIREDTOTESTMSU-60PERNCR95-039, WO¹19501414.
FUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
RETESTIN1996.Fll~MAINSTEAMLOOPAATMOSPHERIC VENTDRAWINGS:
B-9ASummaryExamNumberCateg601590SN-VTItemNumberComponent MSU-60MECHANICAL SNUBBERAUGVT-3NDEComponent TypeExam95VT3BASELINEEXAMDUETOFTTESTINGEXPANSION fTEMP~72DEG.FesSETTING35/8",PSA-3,5"STROKE.NORECORDABLE INDICATIONS
-ACCEPTABLE.
601591SN-FTMSU-60MECHANICAL SNUBBERAUGFT95-FT:OTHERFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFMSU-S7,EXPANDEDEXAM.WO19501414EcNCR95-039.
ACCEPTABLE.
67 eR.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5C.ommercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT.F12.MAINSTEAMLOOPATOAUXFWPUMPTURBINEDRAWINGS:
C-32SummaryExamNumberCateg601630SN-VTItemNumberComponent Component TypeMSU-78AUGMECHANICAL SNUBBERNDEExamVT-395VT3TEMP~76DEG~F5SETTING31/85S/N85765PSA-10,6"STROKE.NORECORDABLE INDICATIONS
-ACCEPTABLE-601631SN-FTMSU-78MECHANICAL SNUBBERAUGFT95-FT:OTHER(FUNCTIONAL TESTOFSNUBBER-ACCEPTABLE.
WOP19404242.
F13.STANDBYAUXFWTHRUPEN123TOBS/GFWHDINCVDRAWINGS:
C-24SummaryNumberExamCategItemNumberComponent NDEComponent TypeExam601940SN-VTAFU-208(AFW-13)HYDRAULIC SNUBBERAUGVT-395-VT-3:TEMP.63DEG.F.,SETTING2",S/N12907.NORECORDABLE INDICATIONS
-ACCEPTABLE.
601941SN-FT----AFU-208(AFW-13)HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBER5'AILED,REPLACEDSNUBBERWOI19404248.
NCR95-044 REQUIREDEXPANSION TOAFU-229,N-616&PS-6.RETESTIN.'96-ACCEPTABLE.
68 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONTtF149STANDBYAUXFWTHRUPEN119TOAS/GFWHDINCVDRAWINGSt C-20SummaryExamNumberCateg601970SN-VTItemNumberComponent AFU-224(AFW-28)HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395-VT-3:BASELINEEXAMDUETOFTTESTINGEXPANSION.
TEMP.68DEG~FfSETTING21/2fFLUIDLEVEL75'tfS/N12905'ORECORDABLE INDICATIONS
-ACCEPTABLE.
601971SN-FTAFU-224(AFW-28)HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-229-EXPANDED EXAMFAILED.WOI19501481NCR95-047.
REPLACEDSNUBBER.REQUIREDTOTESTAFU-226PERNCR95-049 6WOg19501483.
RETESTIN1996.601980SN-VTAFU-226(AFW-27)HYDRAULIC SNUBBERAUGVT-395-VT-3$BASELINEEXAMDUETOFTTESTINGEXPANSION TEMP.67DEG.F.,SETTING31/2",S/N12401.NORECORDABLE INDICATIONS
-ACCEPTABLE.
601981SN-FTAFU-226(AFW-27)HYDRAULIC SNUBBERAUGFT95-FT:OTHERSFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-224.EXPANDEDEXAM-ACCEPTABLE.
WOÃ195014836NCR95-049.
69
R,EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial NerviceDate~Jul19706.National BoardNumberforUnit~NAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F15~PRESSeRELIEFFMPRESS.TORELIEFMANIFOLDDRAWINGS'-2 SummaryExamNumberCateg602080SN-VTItemNumberComponent N616HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395-VT-3:BASELINEEXAMDUETOFTTESTINGEXPANSION (NCR94034)~TEMP~58DEG~F~5SETTING25/85FLUIDLEVEL75%,NORECORDABLE
&OTHERNCOTTERPINONHEAD-OK,PHR-12SUPPORTISWELDEDTOTHEWALLPLATEOFN616-NOBOLTSACCEPTABLE.
AUGN616HYDRAULIC SNUBBER602081SN-FT95-FT:OTHERfFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-208,EXPANDEDEXAM-ACCEPTABLE.
WOE195014466NCR95-044.
FTF16.3-IN.PRESSURIZER RELIEFLINEDRAWINGS:
A-12SummaryNumber602120ExamCategItemNumberComponent SN-VT---PS-6HYDRAULIC SNUBBERComponent TypeAUGNDEExamVT-395-VT-3:BASELINEEXAMDUETOFTTESTINGEXPANSION TEMP.69DEGF~5SETTING35/85S/NPD877671239'EWCOTTERPININSTALLED.
NORECORDABLE INDICATIONS
-ACCEPTABLE.
602121SN-FTPS-6HYDRAULIC SNUBBERAUGFT95-FT:OTHERNFUNCTZONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-2085EXPANDEDEXAM-ACCEPTABLE.
WOP195014476NCR95-044.
70 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5Co.mmercial ServiceDate~cul1970S.National BoardNumberforUnitjNAATTACHMENT ISNUBBERPROGRAMCOMPONENTS CONT~F17STANDBYAUXFWTHRUPEN119TOAS/GFWHDINDRAWINGS:
C-20SummaryExamNumberCategItemNumberComponent NDEComponent TypeExam602500SN-VTAFU-229HYDRAULIC SNUBBERAUGVT-395-VT-3BASELINEEXAMDUETOFTTESTINGEXPANSION TEMP69DEG~FsSETTING21/4sFLUIDLEVEL50'tsS/N21009'ORECORDABLE INDICATIONS
-ACCEPTABLE 602501SN-FTAFU-229HYDRAULIC SNUBBERAUGFT95-FT!OTHERSFUNCTIONAL TESTOFSNUBBERREQUIREDBYFAILUREOFAFU-208,EXPANDEDEXAMFAILED.WOg19501445&NCR95-044.
REPLACEDSNUBBER,REQUIREDTOTESTAFU-224PERNCR95-047
&WOE19501481.
RETESTIN'96.71 ReE~GINNANUCLEARPOWERPLANTkInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul197CS.National BoardNumtecforUnit~NBATTACHMENT IGSEISMICSUPPORTS'l
~RCPSEALWATERRETURN-RELIEFTOPRTDRAWINGS:
SS-1SummaryNumber700110ExamItemCategNumberComponent SS-CS*F1.20RCVU-125GUIDE6IAComponent TypeAUGNDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE G29RCPRESSURERELIEFMANIFOLDTOPRTDRAWINGS:
SS-2SummaryExamNumberCateg700140SS-CSItemNumberComponent
- F1.20RCVU-130RIGIDHANGER6IAComponent TypeAUGNDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
G3.MAINSTEAM DRAWINGS:
B-9ASummaryExamNumberCateg700490SS-CSItemNumberComponent
- F1.20RMSU-53RIGIDSUPPORT6IAOEVT-3NDEComponent TypeExam95-VT-3:NORECORDABLE
&INSIGNIFICANTs LOOSEPARTS,HOLDDOWNBOLTSSOUTHEAST 6SOUTHWEST ARELOOSE,ACCEPTABLE PERNCR94-059.NOTSERVICEINDUCED.700510SS-CS*F1.20RMSU-47RIGIDSUPPORT6IAOEVT-395-VT-3sNORECORDABLE 6INSIGNIFICANTs JACKINGBOLTSLOOSE,LIGHTRUST.LOOSEBOLTSACCEPTABLE PERNCR94-0626NOTSERVICEINDUCED-ACCEPTABLE.
72 0ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)r1.OwnerRochester Gas&ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NA5C.ommercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISEISMICSUPPORTSCont.G3.MAINSTEAM (Cont.)SummaryExamNumberCateg700520SS-CSItemNumberComponent
- F1.20RMSU-48RIGIDSUPPORT&IAComponent TypeOENDEExamVT-395-VT-3sNORECORDABLE
&fINSIGNIFICANTS LOOSEJACKBOLT)LIGHTRUST.ACCEPTABLE PERNCR94-063.NOTSERVICEINDUCEDACCEPTABLE.
G4~RESIDUALHEATREMOVALDRAWINGS:
B-21SummaryNumber700580ExamItemCategNumberComponent SS-CS*F1.20RRHU-87RIGIDSUPPORT&IAComponent TypeOENDEExamVT-395-VT-3$NORECORDABLE INDICATIONS
-ACCEPTABLE INSIGsCORROSION, LIGHTRUSTONBASEPLATE-ACCEPTABLE.
700590SS-CS*F1.20RRHU-90RIGIDSUPPORT&IAOEVT-395-VT-3sNORECORDABLE INDICATIONS
-ACCEPTABLE.
INSIGsCORROSION, RUST&CHIPPEDPAINTONBASEPLATE-ACCEPTABLE.
G5eSeW.TOACWATERCHILLERSDRAWINGS:
C-16SummaryNumberExamCategItemNumberComponent Component TypeNDEExam700740SS-CS*F1.20VSWU-364OEVARIABLESPRING&IAVT-395-VT-3NORECORDABLE INDICATIONS
-ACCEPTABLE.
TEMP.55DEG.F.,SETTING=1.05=1456if'SfN-EG-13312-82-308 TYPEBfSIZE10~NOTEsPLATEg3TOBEAM(WSX35)WELDISWELDEDALLAROUND~73 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriodsThirdOutage(1995)I1.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAB.commercial ServiceDate~Jul197DS.National BoardNumberforUnit~NAATTACHMENT ISEISMICSUPPORTSCont.G6.STANDBYAUXFEEDWATER DRAWINGS:
C-28ASummaryExamNumberCateg700790SS-CSItemNumberComponent
- F1.20RSWU-525U-BOLTComponent TypeAUGNDEExamVT-395-VT-3:NORECORDABLE INDICATIONS
-ACCEPTABLE.
74
0R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.Commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT IH~STEAMGENERATOR EDDYClJRRENTEXAMINATIONS-Hl~STEAMGENERATOR ASummaryExamNumberCateg800000B-QItemNumberB16.20Component OPENGENERATOR TUBESPREV.IDENT.DEGRAD20Component TypeASMENDEExamETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.800150B-QB16.20OPENGENERATOR TUBESASME20'%OTATING RANDOMSAMPLEETET95-ET<SEE1995EDDYCURRENTREPORTFORDETAILS.800200SG-ET----OPENGENERATOR TUBESOE100%OFALLUNSLEEVED TUBESETET95-ETsSEE1995EDDYCURRENTREPORTFORDETAILS800350B-QB16.20SLEEVEDGENERATOR TUBES20%ROT.RAN.SAM.EACHTYPESLEEVEASMEETETETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.a800360-------WEARIND.COLDLEG-2ND/3RD SPR1C10-RlC12, R2C106R2C12,R3C10-R3C12 OEET95-ET:ALLTUBESINSPECTED DURING1994.TUBESRlcloEcR1C12TUBESINSPECTED 1995.NODETECTABLE DEFECTSIDENTIFIED ACCEPTABLE.
75 R.E~GINNANUCLEARPOWERPLANTrInservice Inspection Report1990-1999
- Interval, SecondPeriodsThirdOutage(1995)l.OwnerRochester Gas6ElectricCor.89EastAve.Rochester NY146492.PlantR.E.Ginna NuclearPowerPlant1503LakeRoadOntarioNY145193.PlantUnit14.OwnerCertificate ofAuthorization (IfReq.)~NAS.commercial ServiceDate~Jul1970S.National BoardNumberforUnit~NAATTACHMENT ISTEAMGENERATOR EDDYCURRENTEXAMINATIONS CONT~H2,STEAMGENERATOR BSummaryExamNumberCategItemNumberComponent Component TypeNDEExam801000B-QB16.20OPENGENERATOR TUBESASMEPREV.IDENT.DEGRADE20%ETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.801150B-QB16.20OPENGENERATOR TUBESASME20%ROTATINGRANDOMSAMPLEETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.801200SG-ET----OPENGENERATOR TUBESOE100%OFALLUNSLEEVED 100%OFALLUNSLEEVED 95-ET!SEE1995EDDYCURRENTREPORTFORDETAILS.ETET801350B-QB16.20SLEEVEDGENERATOR TUBES20%ROT.RAN.SAMEACHTYPESLEEVEASMEETETETET95-ET:SEE1995EDDYCURRENTREPORTFORDETAILS.76 FORMNIS-2OWNER'SREPORTFORREPAIRSORREPLACEMENTS AsRcdluircd bytheProvisions ofthcASMECodeSectionXI1.OwnerRochester GasgElectricCor.Date24Gul199589EastAve.Rochester NY14649Sheet2.PlantR.E.GinnaNuclearPowerPlatttVnitof241503LakeRoadOntarioNY14519AddressRepairOrganization P.O.No.,JobNo.,ctc.3.WorkPerformed byNameTypeCodeSymbolStampAuthorization No.NANAAddressExpiration DateNA4.Identification ofSystemd.(lApplloOlCtooloCod~lp~Edloo,~Addd,CodeCase(b)Applicable EditionofSectionXIUtilizedforRepairsorReplaccmcnts 19866.Identification ofComponents RepairedorReplacedandReplacement Components NameofComponent NameofManufacturer Manufacturer SerialNo.NationalBoardNo.OtherIdcntiCicationYearBuildRepairedReplacedofReplaccmcnt ASMECodeStamped(YcsorNo)7.Description ofWork8.TestsConducted:(a)
Hydrostatic 0Pneumatic 0NominalOperating Pressure0Other0PrcssurepsiTestTemp.'FNOTE:Supplcmcntal shcctsinformoflists,skctchcs, ordrawingsmaybeused,provided(I)sizeis8-1/2in.x11in.,(2)information initemsIthrough6onthisrcportisincludedoneachshcct,and(3)eachsheetisnumberedandthenumberofshcctsisrecordedatthetopof'thisform.()SceATI'ACHMENT II"FORAPPLICABLE INFORMATION (12/82)ThisForm(E00030)maybcobtainedfromthcOrderDept.,ASME,345E.47thSt.,NewYork,N.Y.10017I FORMNIS-2(Back)9.Remarks Applicable Manufacturer's DataReportstobcattachedCERTIFICATE OFCOMPLIANCE Wccertifythatthestatements madeinthcreportarecorrectandthisASMECode,SectionXI.repairorreplacement conlortns totherulesofthcN/ATypeCodeSymbolStampICcrtificat ofuo'nNo.N/AExpiration DateSinedF.A.KlcackiISIEnineerDate24JulOwnerorOwner'sDesignee, TitleN/A1995CERTIFICATE OFINSERVICE INSPECTION I,theundcrsigncd, holdingavalidcommission issuedbytheNationalBoardofBoilerandPressureVesselInspectors andtheStateorProvinceofNcwYorkandemployedbyHSBI/klCn.ofHartfordCT.haveinspcctcd thecomponents dcscribcd inthisOwner'sRcportduringtheperiod/toW9Mandstatethattothebestofmyknowledge andbclicf,theOwnerhasperformed examinations andtakencorrective mcasurcsdcscribcd inthisOwner'sRcportinaccordance withtheinspection planandasrequiredbytheASMECodc, SectionXI.Bysigningthiscertilicate neitherthcInspector norhisernploycr makesanywarranty, expressed orimplied,concerning theexaminations andcorrective measuresdescribed inthisOwner'sRcport.Furthcrmorc, ncithcrthcInspector norhiscmploycrshallbeliableinanymannerforanypersonalinjuryorpropertydamageoralossofanykindarisingfroinorconncctcd withthisinspection.
AWE8.N.6ccrInspector's Signature Date7195'~Commissions NationalBoard,State,Province, andEndorsements (e)SeeATI'ACHMENT II"FORAPPLICABLE INFORMATION
(~')Repair,Replacement orModification asidcntilied within"ATTACHMENT II
RoE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester Gas8ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant,1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications:
1986NoAddendaATTACHMENT IIREPAIRREPLACEMENT andMODIFICATION PROGRAMTheRepair,Replacement andModification (RR&M)Program,asidentified withinthe"Appendix B"ProgramoftheGinnaStationQualityAssurance Manual,identifies component jurisdiction andassociated requirements.
Applicable Repair,Replacement orModification activities havebeenperformed inaccordance withASMESectionXICode,1986edition,noaddenda.Whenanitemundertherulesandrequirements ofthe"Appendix B"Programisfounddeficient, anEngineering "use-as-is" evaluation mayresult.Thisdetermination isindicated withintheISIProgramSummary,"Attachment I",fortheapplicable component withinthisreport.Ifthedeficiency resultsinaCodeRepair,Replacement orModification; thedeficiency willbeclassified asoneofthreecategorytypes.Thesecategorytypesshallconsistofa"CodeServiceInducedRejectable Indication",
a"CodeRejectable Indication" anda"Corrective ActionActivity".
A"CodeServiceInducedRejectable Indication" occurswhenacomponent undertheRR&MProgramcontainsanindication thatisbeyondASMESectionXICodeacceptable standards andwasdetermined tobe"ServiceInduced".
"ServiceInduced"indications, stemmingfromInservice Inspection Examinations (ISI),shallrequireadditional expandedexaminations.
Theassociated expandedexaminations shallbeperformed inaccordance totherequirements oftheASMESectionXICode.A"CodeRejectable Indication" occurswhenacomponent undertheRR&MProgramcontainsanindication thatisbeyondASMESectionXICodeacceptable standards andwasdetermined tobenot"ServiceInduced".
Thiscategoryincludesbutisnotlimitedtoitemssuchasweldingdiscontinuities fromamodification identified duringISIpreservice examinations orcomponent damagecausedbyhumaninvolvement.
R.EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1~Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.Plant!R.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications:
1986NoAddendaATTACHMENT IIA"Corrective ActionActivity" mayoccurwhenacomponent undertheRR&MProgramrequirescorrective action.Thiscorrective actionmaybearesultfromamaintenance operation thatidentifies aneedtoperformaCodeRepair,Replacement orModification.
Thiscategoryincludes'but.isnotlimitedtoitemssuchasmachining acomponent tocorrectanidentified problemortheremovalandlaterreapplication ofhardfacematerialonpressureboundarysurfaces.
Thefollowing groupshaveperformed applicable Repair,Replacement andModification activities duringthe1993Outage.Eachgrouphasbeenidentified byanumberandwillcorrespond tothegroups'ame andaddress.Rochester GasandElectric, GinnaStationdepartments willnotbeidentified aslikecontractors butbygenericname.InthebelowlistingofRepairs,Replacements orModifications; theworkgroupwillbeidentified byanumberwithinthecomponent discussion.
Rochester Gas&Electric, GinnaStation2~GinnaStationProjectsDepartment NuclearPowerServicesPhiladelphia, Pa.3.ITIMovats2825CobbInternational Blvd.Kennensaw, Ga.30144-5512 4~5.ABB-Combustion Engineering, Inc.,1000ProspectHillRoadP.O.Box500Windsor,Connecticut 06095-0500 Babcock&WilcoxLynchburg, Virginia R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner!Rochester Gas8ElectricCo.89E.Ave.Rochester N.Y.146492~PlanttR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModifications:
1986NoAddendaATTACHMENT IIThefollowing information willreportapplicable Repairs,Replacements orModifications performed atR.E.GinnaNuclearPowerPlantduringthisreporting periodasrequiredbyASMESectionXICode.1~ASMEClass:3~Sstem:SWGORRNo.:95-E-001Construction Code:ASMESectionIII'86;B31.1'73;B16.34WorkPerformed B:1NameofComonent:V4620,SwivelNutWorkDescritionRemarks:An"Approved Equivalent" Replacement wasinitiated fortheSwivelNutassociated withV4620andtoreattachthedisctothestem.Thisactivitywascontrolled byWOk19402994&NCR94-106.Construction CodeVTexamination wasperformed andacceptable.
Uponactivityconclusion, aVT-2LeakageExamination wasperformed
&acceptable.
2.ASMEClass:3~Sstem:SWGORRNo.:95-E-002Construction Code:ASMESectionIII'86;B31.1'73;B16.34WorkPerformed B:2NameofComonent:V4603ReliefReuest:g25WorkDescritionRemarks:AModification activitywasinitiated toreplaceV4603withaNozzleCheckValveandaFlangewithextendedlength.Thisactivitywascontrolled byEWR5284BandSM5284B.2.Construction CodeRTNDEwasperformed andacceptable inaccordance withthespecified ReliefRequest.AVT-2LeakageExamination wasperformed andacceptable.
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner:Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.Plant!R.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofsectionXIUtilizedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II3~ASMEClass:2~Sstem:MSGORRNo.:95-E-003Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:MSU-18(South)Mechanical SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheMechanical Snubberassociated withComponent SupportMSU-18(South).Thisactivitywascontrolled byWOg19404245andNCR95-017.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable.
4.ASMEClass:2~Sstem:SAEWGORRNo.:95-E-005Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:AFU-208Hydraulic SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheHydraulic Snubberassociated withComponent SupportAFU-208.Thisactivitywascontrolled byWOg19404248andNCR95-044.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable.
5.ASMEClass:2~Sstem:MSGORRNo.:95-E-006Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:MSU-57Mechanical SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheMechanical Snubberassociated withComponent SupportMSU-57.Thisactivitywascontrolled byWOg19404247andNCR95-039.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable.
RaE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1~Owner!Rochester gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlanttR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II6.ASMEClass:2~Sstem:SAFWGORRNo.:95-E-007Construction Code:ASMESectionIII'74/'86WorkPerformed B:1NameofComonent:AFU-229Hydraulic SnubberWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated fortheHydraulic Snubberassociated withComponent SupportAFU-229.Thisactivitywascontrolled byWOg19501481andNCR95-047.Uponreinstallation, aVisualBaselineexamination wasperformed andacceptable.
7~ASMEClass:3~Sstem:SWGORRNo.:95-E-009Construction Code:ASMESectionIII86FB31~173B16~34WorkPerformed B:1NameofComonent:V4604ReliefReuest:g25WorkDescritionRemarks:AModification activitywasinitiated toreplaceV4604withaNozzleCheckValveandaFlangewithextendedlength.Thisactivitywascontrolled byEWR5284BandSM5284B.3.-ASMESectionIIIConstruction CodeRTNDEwasperformed andacceptable inaccordance withthespecified ReliefRequest.AVT-2LeakageExamination wasperformed andacceptable.
(SeeGORR95-T-024).
RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications t1986NoAddendaATTACHMENT II8.ASMEClass:1~Sstem:RCS-S/GGORRNo.:95-E-010Line:N/AConstruction Code:ASMESectionIII'86WorkPerformed B:5NameofComonent:SteamGenerator "A&B"(EMSO1A,EMSO1B)Tubes,Explosive Sleeves/Plugs.
WorkDescritionRemarks:DuringtheEddyCurrentExamination ofSteamGenerator "A&B",tubescontaining defectswereidentified anddetermined tobecandidates forB&Wbimetallic explosive sleevesorplugs.Atotalof75B&Wexplosive sleevesand3B&Wexplosive plugswasinstalled inthe"A"SteamGenerator.
Atotalof91B&Wexplosive sleevesand8B&Wexplosive plugswasinstalled inthe"B"SteamGenerator.
Thelocationofthesedefective tubesareidentified withintheEddyCurrent"1995FinalExamination ReportforSteamGenerators".
Thisactivitywascontrolled byGinnaStationMaintenance Procedures M43.16&M43.43.3, andB&Wdocument51.-1212535-01.
Uponcompletion oftheinstallation
- activity, EddyCurrentexaminations wereperformed andacceptable onthesleeves.NoEddyCurrentexamination wasperformed onthePlugs.EddyCurrentSleeveExaminations arealsoutilizedtoverifyproperweldlocationandprovidescomparison toensureweldsoundness.
RE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnertRochester Gas8ElectricCo.89E.Ave.Rochester N.Y.146492~Plant!R.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II9.ASMEClass:1~Sstem:RCS-S/GGORRNo.:95-E-011Line:N/AConstruction Code:ASMESectionIII'86WorkPerformed B:4NameofComonent:SteamGenerator "B"(EMS01B)Tubes,WeldedPlugs.WorkDescritionRemarks:DuringtheEddyCurrentExamination ofSteamGenerator "B",atotalof10tubescontaining defectswereidentified anddetermined tobecandidates forCEweldedplugs.Atotaloften(10)weldedCEPlugswereinstalled inthe"B"SteamGenerator.
Thelocationofthesedefective tubesareidentified withintheEddyCurrent"1995FinalExamination ReportforSteamGenerators".
Thisactivitywascontrolled byGinnaStationMaintenance Procedure M43.55andCEReportCEN-320-P.Uponcompletion oftheinstallation
- activity, VTExaminations wereperformed andacceptable.
10.ASMEClass:3~Sstem:MSGORRNo.:95-T-001Construction Code:B31.1'73/'86;B16.34WorkPerformed B:1NameofComonent:V3519,Studs&NutsWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated toinstallnewStuds&Nutsassociated withV3519.Thisactivitywascontrolled byWOg's19401812, 19402976andNCR94-103.Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable.
RaE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlanttR.E.GinnaNuclearpowerplant1503LakeRd.OntarioN.Y.145193~APPlicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications!
1986NoAddendaATTACHMENT II11.ASMEClass:2~Sstem:CVCS-Letdown GORRNo.:95-T-003'":'"-"'/'-'onstruction Code:VIII'65;W676257;B31.1'55.WorkPerformed B:1NameofComonent:V203WorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated toinstallarebuiltspareReliefValveassociated withV203.Thisactivitywascontrolled byWOg's19402556,
- 19401923, 19401901&19401833.
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable.
12.ASMEClass:3~Sstem:MS~GORRNo.:95-T-004Construction Code:B31.1'86;B16.341SP-5291.WorkPerformed B:1NameofComonent:V3518Studs&NutsWorkDescritionRemarks:ALike-for-Like Replacement activitywasinitiated toinstallnewStuds&Nutsassociated withV3518.Thisactivitywascontrolled byWOg19402162.
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable.
13.ASMEClass:3~Sstem:SWGORRNo.:95-T-005Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291WorkPerformed B:1NameofComonent:PSW01C(SWPumpC)WorkDescritionRemarks:ServiceWaterPumpCBowlAssemblywithShaftwasreplacedwithapreviously rebuiltitems.Also;someboltingwasreplacedwithapprovedequivalent bolts.Thisactivitywascontrolled byWOg's19402122, 19321060andTSEE91-546.Uponreinstallation, anASMESectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.110 ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeri.od,ThirdOutage(1995)l.Owner:Rochester Gas5ElectricCo.89E.Ave.Rochester N.Y.146492.PlantiR.E.GinnaNuclearPowerPlant1503LakeRd.Ontari.oN.Y.145193~Applicable Editi:onofSectionXIUtilisedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II14.ASMEClass:3~Sstem:SWGORRNo.:95-T-006Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291WorkPerformed B:1NameofComonent:PSW01A(SWPumpA)WorkDescritionRemarks:ServiceWaterPumpABowlAssembly, Discharge CaseandShaftwasreplacedwithpreviously rebuiltitems.Thisactivitywascontrolled byWOg's19403555and19402161.
Uponreassembly, anASME'SectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.115.ASMEClass:2~Sstem:SIGORRNo.:95-T-007-'"/'/'"Construction Code:ASMEIII83W85/'86.WorkPerformed B:1NameofComonent:V874E&Pipingdownstream V1820C.WorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated toinstallanewglobevalve(V874E)withassociated piping.Thisactivitywascontrolled byNCR94-169 andWOg19403601.
Construction CodeVT&PTexaminations wereperformed andacceptable.
AnASMESectionXIhydrostatic testwithaccompanying VT-2examination wasperformed underRSSP15.6andacceptable.
16.ASMEClass:2~Sstem:SlGORRNo.:95-T-008Construction Code:ASMEIII83W85WorkPerformed B:1NameofComonent:V891CHingePin.WorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated fortheassociated HingePinofV891C.Thisactivitywascontrolled byWOg's19403641and19403627.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
11
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriodsThirdOutage(1995)1~Owner!Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.plant:R.E.GinnaNuclearpowerplant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModificationst 1986NoAddendaATTACHMENT II17.ASMEClass:2~Sstem:BlowdownGORRNo.:95-T-009Construction Code:ASMEIII'74/86WorkPerformed B:1NameofComonent:BDU-21,RigidSupportWorkDescritionRemarks:Areplacement activitywasinitiated forBDU-21rigidsupportthatwasinadvetingly removedandrequiredreinstallation.
Thisactivitywascontrolled byWO.g19403648andNCR94-102.
Construction Codeexaminations wereperformed andacceptable.
AnASMESectionXIvisualBaselineexamination wasperformed andacceptable.
18.ASMEClass:3~Sstem:CCWGORRNo.:95-T-01010H-AC5-152 Construction Code:ASMEIII'86;B16.34WorkPerformed B:1NameofComonent:V780A/BFlangeStudsWorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated forFlangeStudsassociated withValves780A6B.Thisactivitywascontrolled byWOg19402526.
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable.
19.ASMEClass:3~Sstem:SWGORRNo.:95-T-011Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291WorkPerformed B:1NameofComonent:PSW01C(SWPumpC)WorkDescritionRemarks:ServiceWaterPumpCBowlAssemblywithShaftwasreplacedwithpreviously rebuiltitems.Thisactivitywascontrolled byWOg's19404042and19403611.
Uponreassembly, anASMESectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.1 R.EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester GasEElectricCo.89E.Ave.Rochester N.Y.146492.PlanttR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications:
1986NoAddendaATTACHMENT II20.ASMEClass:3~Sstem:SWGORRNo.:95-T-013Line:N/AConstruction Code:GilbertSpecsRO-2204;SP-5291;II'86.WorkPerformed B:1NameofComonent:PSW01B(SWPumpB)WorkDescritionRemarks:ServiceWaterPumpBBowlAssembly, Intermediate Shaft,ImpellerShaft,SuctionBellandassociated Boltingwasreplacedwithpreviously rebuiltornewitems.Thisactivitywascontrolled byWOg's19402721and19404138.
Uponreassembly, anASMESectionXIIWA5244FlowTestwasperformed andacceptable underPT2.7.121.ASMEClass:3~Sstem:SWGORRNo.:95-T-014Construction Code:ASMEIII86)B31~155(RO2167WorkPerformed B:1NameofComonent:Expansion JointSSW04,SupportsSWU-629/633 Work.Descri tionRemarks:Areplacement activitywasinitiated foranewExpansion Joint,modifysupport.SWU-633andthereplacement ofmiscellaneous itemssuchasbolts,nutsect.Thisactivitywascontrolled byEWR5284B,TSR93-520, NCR94-128,SM-5284B.2
&WOg19404933.
Afterinstallation, Construction CodeVTexaminations aswellasSectionXIbaselineexaminations wereperformed andacceptable.
Also;ASMESectionXILeakageexamination wasperformed andacceptable.
(Note:seeGORR95-E-002) 22'SMEClass:3~Sstem:CCWGORRNo.:95-T-016Construction Code:ASMEIII'74/'86WorkPerformed B:1NameofComonent:CCU-159RigidRestraint.
WorkDescritionRemarks:Areplacement activitywasinitiated toinstallwashersinCCU-159,RigidRestraint Component Support,andalsototorqueHiltiBolts.Thisactivitywascontrolled byWOg19404910andNCR94-125.
Uponinstallation, anASMESectionXIBaselineVTexamination wasperformed andacceptable.
13 4tl R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492~PlanttR.E.GinnaNuclearPowerPlan81503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II23.ASMEClass:3~Sstem:AFWGORRNo.:95-T-017Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4000AStem&Disc.WorkDescritionRemarks:Areplacement activitywasinitiated toinstallanewStem&Discassociated withValve4000A.Thisactivitywascontrolled byWOg's19402916and19402936.
BodytoBonnetweldareawaspreppedandanewSealWeldwasapplied.Construction CodePTexamination wasperformed andacceptable.
Uponcompleting thereassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
24.ASMEClass:3~Sstem:SAFEGORRNo.:95-T-018Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9703BStem&Disc.WorkDescritionRemarks:Areplacement activitywasinitiated toinstallanewStem&Discassociated withValve9703B.Thisactivitywascontrolled byWOg19402953.
BodytoBonnetweldareawaspreppedandanewSealWeldwasapplied.Construction CodePTexamination wasperformed andacceptable.
Uponcompleting thereassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
25.ASMEClass:3~Sstem:SWGORRNo.:95-T-020Construction Code:B31.1'73;B16.34;ASMEIII'86.WorkPerformed B:1NameofComonent:V4622.ReliefReuest:g25WorkDescritionRemarks:AnApprovedEquivalent replacement activitywasinitiated toinstallasparevalvefromstockforV4622.Thisactivitywascontrolled byNCR94-009, TE93-548&WOg19400868.
Construction CodeVT&PT(Root&FinalWeld)examinations wereperformed andacceptable.
AnASMESectionXILeakageexamination wasperformed andacceptable.
14
R.E~OINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester GasaElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.OinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilisedforRePairs,Replacements orModificationss 1986NoAddendaATTACHMENT II26.ASMEClass:1~Sstem:Pressurizer GORRNo.:95-T-021Construction Code:ASMEIII'83/'85/'86.
WorkPerformed B:3NameofComonent:V515.WorkDescritionRemarks:AnApprovedEquivalent replacement activitywasinitiated toinstallanewvalve.Thisactivitywascontrolled byNCR94-068, EWR3755&WO¹19402868.
Construction CodeRT&PTexaminations wereperformed andacceptable.
ASMESectionXIBaselinePTexamination aswellasaHydrostatic Testwithaccompanying VT-2examination wasperformed andacceptable.
27.ASMEClass:1~Sstem:Pressurizer GORRNo.:95-T-022Construction Code:ASMEIII'83/'85/'86.
WorkPerformed B:3NameofComonent:V516.WorkDescritionRemarks:AnApprovedEquivalent replacement activitywasinitiated toinstallanewvalve.Thisactivitywascontrolled byNCR95-073
&WO¹19402865.
Construction CodeRT&PTexaminations wereperformed andacceptable.
ASMESectionXIBaselinePTexamination aswellasaHydrostatic Testwithaccompanying VT-2examination wasperformed andacceptable.
28.ASMEClass:3~Sstem:SWGORRNo..95-T-023Construction Code:ASMEIII'86;B31.1'73WorkPerformed B:3NameofComonent:V4607WorkDescritionRemarks:A.Like-for-Like replacement activitywasinitiated forV4607Bolting&Stem.WeldRepairswerealsoperformed totheValveSeats&Disc.Thisactivitywascontrolled byWO¹19221485&MovatsDR95-05/-06/-08/-14.
Construction CodePTexaminations fortheWeldRepairsoftheSeat&Discwereperformed andacceptable.
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable.
15 R.EGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester Gas6ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofsectionXIUtilizedforRepairs,Replacements orModifications:
1986NoAddendaATTACHMENT II29.ASMEClass:3~sstem:SWGORRNo.:95-T-024Construction Code:ASMEIII'86FB31.1'55;RO-2167WorkPerformed B:1NameofComonent:Expansion JointSSW05,SupportsSWU-630/634 WorkDescritionRemarks:Areplacement activitywasinitiated foranewExpansion Joint,modifysupportsSWU-630/6343 andthereplacement ofmiscellaneous itemssuchasbolts,nutsect.Thisactivitywascontrolled byEWR5284B,TSR93-520, SM-5284B.3&WOg19500499.
Afterinstallation, Construction CodeVTexaminations forthesupportsaswellasSectionXIbaselineexaminations wereperformed andacceptable.
Also;ASMESectionXILeakageexamination wasperformed andacceptable.
(Note:seeGORR95-E-009) 30.ASMEClass:3~Sstem:SWGORRNo.:95-T-026Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4608WorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated forV4608Stem.WeldRepairswerealsoperformed totheValveSeats&Disc.Thisactivitywascontrolled byWO19221483.
Construction CodePTexaminations fortheWeldRepairsoftheSeat&Discwereperformed andacceptable.
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable.
31.ASMEClass:3~Sstem:FWGORRNo.:95-T-027Line:4-FW-900-1 Construction Code:B31.1'73;B16.34;SP-5291FASMEIII'86.WorkPerformed B:3NameofComonent:V4271WorkDescritionRemarks:AReplacement activitywasinitiated toinstallanewStem,Cage&Plungerassociated withV4271.Thisactivitywascontrolled byTSR90-126
&WOg19402472.
Uponreinstallation, anASMESectionXILeakageexamination wasperformed andacceptable.
16
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner:Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492~PlanttR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications!
1986NoAddendaATTACHMENT II32'SMEClass:3~Sstem:SAFEGORRNo.:95-T-029.Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9701BWorkDescritionRemarks:AReplacement activitywasinitiated toinstallanewStemAssemblyassociated withV9701B.Thisactivitywascontrolled byWOg19402948.
Uponreinstallation, anASMESectionXIVT-2examination wasperformed andacceptable.
33.ASMEClass:2~Sstem:SAFWGORRNo.:95-T-030Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9704BWorkDescritionRemarks:ALike-for-Like replacement activitywasinitiated forV9704BStem.Theworkactivityalsocoveredthereapplication oftheBodytoBonnetSealWeld.Thisactivitywascontrolled byWOg19402959.
Construction CodePTexamination fortheSealWeldwasperformed andacceptable.
AnASMESectionXIVT-2examination wasperformed,and acceptable.
34.ASMEClass:2/3~Sstem:SAFWGORRNo.:95-T-031Construction Code:ASMEIII'74/'86WorkPerformed B:3NameofComonent:V9704A;AFU-231WorkDescritionRemarks:Areplacement activitywasinitiated forV9704AStemandthereapplication oftheBodytoBonnetSealWeld.Component SupportAFU-231wasalsoremovedandreinstalled inordertoprovideaccessfortheoriginalworkscope.Thisactivitywascontrolled byWOg19402956.
Construction CodePTexamination fortheSealWeldandVTexamination forthesupportwasperformed andacceptable.
ASMESectionXIBaselineVTexamination forthesupportandVT-2examination wasperformed andacceptable.
17 ReE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModificationst 1986NoAddendaATTACHMENT II35.ASMEClass:3~Sstem:SWGORRNo.:95-T-032Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4668AWorkDescritionRemarks:Areplacement activitywasinitiated forV4668AStem.Thisactivitywascontrolled by,WO¹19221535.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
36.ASMEClass:3~Sstem:SWGORRNo.:95-T-033Construction Code:ASMEIII'86;B31.1'73;B16.34WorkPerformed B:3NameofComonent:V4561AWorkDescritionRemarks:Areplacement activitywasinitiated forV4561A.Thisactivitywascontrolled byWO¹19402895.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
37.ASMEClass:3~Sstem:MSGORRNo.:95-T-034Construction Code:ASMEIII'86;B31.1'73/'86;B16.34WorkPerformed B:1&3NameofComonent:V3518WorkDescritionRemarks:Areplacement activitywasinitiated forV3518Shaft&Keys.Weldrepairswerealsoperformed totheDiscArmandtheapplication ofTackWeldstotheNuttoDiscPost.ThisActivitywascontrolled byWO¹19402322andNCR95-021.
Construction CodePTExaminations wereperformed ontheweldedareasandacceptable.
Uponreassembly, anASMESectionXILeakageexamination (ISIExam95411400) wasperformed andacceptable.
RE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner!Rochester Gas&ElectricCo.S9E.Ave.Rochester N.Y.146492.PlanttR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications!
1986NoAddendaATTACHMENT II38.ASMEClass:3~Sstem:RCSGORRNo.:95-T-035Construction Code:B31.1'73/'86;B16.34;VIII'65;WE-676279WorkPerformed B:1NameofComonent:V434WorkDescritionRemarks:Thisactivitywasinitiated toreplaceV434witharebuiltunit,nointernalvalvecomponents werereplaced.
Thisactivitywascontrolled byWOg19402658.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
39.ASMEClass:l~SstemRCSGORRNo.:95-T-036Construction Code:B31.1'73/'86;B16.34;VIII'65;WE-676279WorkPerformed B:1NameofComonent:V435WorkDescritionRemarks:Thisactivitywasinitiated toreplaceV435witharebuiltunit,nointernalvalvecomponents werereplaced.
Thisactivitywascontrolled byWOg19402659.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
40.ASMEClass:3~Sstem:SWGORRNo.:95-T-037Construction Code:B31.1'73/'86;SP-5291WorkPerformed B:1NameofComonent:BlindFlangeNuts/Bolts Downstream ofV4640WorkDescritionRemarks:Thisactivitywasinitiated toreplaceassociated Nuts/Bolts ofBlindFlangeDownstream ofV4640.Thisactivitywascontrolled byWOg19500531.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.OwnersRochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications:
1986NoAddendaATTACHMENT II41.ASMEClass:3~Sstem:DGGORRNo.:95-T-038Construction Code:B31.1'73/'86;SP-5291;ASMEVIIIWorkPerformed B:1NameofComonent:V5960&1FlangeNut/BoltWorkDescritionRemarks:Thisactivitywasinitiated toreplaceoneNut/BoltonaFlangeaswellasforreplacing V5960.Thisactivitywascontrolled byWOg19402512.
Upon,reassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
42.ASMEClass:2~Sstem:MSGORRNo.:95-T-039Construction Code:B31.1'73;SP-5291;B16.34;ASMEIII'86WorkPerformed B:3NameofComonent:V3505AWorkDescritionRemarks:Thisactivitywasinitiated toreplacetheStem&Discassociated withV3505A.Thisactivitywascontrolled byWOI19501151.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
43.ASMEClass:3~Sstem:CVCS/CCWGORRNo.:95-T-040Line:N/AConstruction Code:ASMEVIIIWorkPerformed B:1NameofComonent:ECH05,Non-Regen Hx.WorkDescritionRemarks:Thisactivitywasinitiated toreplacetwo(2)StudsontheNon-Regenerative HeatExchanger.
Thisactivitywascontrolled byWOg19221031.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andresultswereunacceptable.
AnActionReport(95-202)wasgenerated.
20
R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester GasaElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModificationss 1986NoAddendaATTACHMENT II44.ASMEClass:3~Sstem:AFWGORRNo.:95-T-041Construction Code:B31.1'73;SP-5291;ASMEIIX'86WorkPerformed B:3NameofComonent:V4010WorkDescritionRemarks:Thisactivitywasinitiated toreplacetheDi'scAssemblyassociated withV4010.Thisactivitywascontrolled byWOg19402939.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
45.ASMEClass:2~Sstem:MS6B-MS-600-1B Construction Code:B31.1'73;ASMEIII'77/75&'86WorkPerformed B:3NameofComonent:V34116V3410WorkDescritionRemarks:Thisreplacement activitywasinitiated toinstallaDiffuser/Pilot PluginV3411andaStemPilotAssemblyinV3410.Theseactivities werecontrolled by.WOg's19402924and19402925.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
46.ASMEClass:2~Sstem:CSGORRNo.95-T-043Line:3A-SI-301 Construction Code:SP-5291;ASMEIII'74/'86WorkPerformed B:1NameofComonent:CSU-72,Component SupportWorkDescritionRemarks:Thisactivitywasinitiated toinstallanutonComponent SupportCSU-72.Thisactivitywascontrolled byWOg19501405.
Uponassembly, propertorqueverification wasperformed andacceptable.
Noadditional ASMESectionXXBaselineExaminations wereperformed sincethisComponent SupportislocatedonanExemptLine.21 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.Owner:Rochester Gas6ElectricCo.89E.Ave.Rochester N.Y.146492.Plant!R.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications!
1986NoAddendaATTACHMENT II47.ASMEClass:2~Sstem:CVCSGORRNo.:95-T-044Construction Code:B31.1'73/'86;B16.34WorkPerformed B:1NameofComonent:V371WorkDescritionRemarks:Thisactivitywasinitiated toinstallaPlug/Stem Assemblyassociated withV371.Thisactivitywascontrolled byWO¹19501329.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
48.ASMEClass:2~Sstem:HHSGORRNo.:95-T-045Line:150-4Construction Code':B31.1'55;ASMEIII'86;SP-5291WorkPerformed B:1NameofComonent:CappedPenetrations 301&303WorkDescritionRemarks:Thisactivitywasinitiated toremoveHHSSystempipingandcappingPenetrations 301and302.Theworkwascontrolled byWO¹19320570&TSR93-067.
Construction CodeVT&PTexaminations wereperformed andacceptable associated withtheendcaps.Uponcompletion ofthisactivity, anAppendixJPressureTestwasperformed
&acceptable.
49.GORRNo.:95-T-046Corrective ActionActivityASMEClass:3~Sstem:MS1.5D-MS-600-1 Construction Code:B31.173IASMEIII86B1634)SP5291WorkPerformed B:1NameofComonent:V8527&V8528WorkDescritionRemarks:Areplacement activitywasinitiated toinstallnewvalvesassociated withV8527&V8528.Theseactivities werecontrolled byWO¹'s19404707and19403598.
Construction CodeVT&MTexaminations wereperformed andacceptable.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
AnActionReport(95-171)wasgenerated fortheimproperapplication ofASMESectionXILeakageexamination.
ReliefRequest¹30wasalsogenerated.
22
ReE.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)l.OwnersRochester Gas&ElectricCo.S9E.Ave.Rochester N.Y.146492~PlanttR.E.QianaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193~Applicable EditionofSectionXIUtilisedforRepairs,Replacements orModifications:
1986NoAddendaATTACHMENT II50.ASMEClass:3~Sstem:AFWGORRNo.:95-T-047Construction Code:B31.1'73:ASMEIII'86;B16.34;SP-5291WorkPerformed B:3NameofComonent:V4007WorkDescritionRemarks:Thisactivitywasinitiated toinstallanewStem&SeatRingsassociated withV4007.Thisactivitywascontrolled byWOg19501545.
Uponreassembly, anASMESectionXILeakageexamination wasperformed andacceptable.
51.ASMEClass:2~Sstem:SIGORRNo.:95-T-048Construction Code:B31.1'73;B16.34;ASMEIII'86WorkPerformed B:1NameofComonent:V1820CWorkDescritionRemarks:Thisactivitywasinitiated toreplaceV1820C.Thisactivitywascontrolled byWOg19403628.
Construction CodeVT&PTexaminations wereperformed andacceptable.
Uponcompletion ofthisactivity, anASMESectionXIHydroTestandaccompanying VT-2examination wasperformed andacceptable.
23 S
R~E'GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999Interval, SecondPeriod,ThirdOutage(1995)1.Owner:Rochester Gas&ElectricCo.89E.Ave.Rochester N.Y.146492.PlantsR.E.GinnaNuclearPowerPlant1503LakeRd.OntarioN.Y.145193.Applicable EditionofSectionXIUtilizedforRepairs,Replacements orModifications:
19S6NoAddendaATTACHMENT II52.ASMEClass:2~Sstem:S/GBlowdownGORRNo.:95-T-049Line:"B"LoopConstruction Code:B31.1'73;ASMEIII'74/'86.WorkPerformed B:1&2NameofComonent:S/GBlowdown"B"Loop;Piping&Supports, insideContainment.
CodeCase:N-416WorkDescritionRemarks:Areplacement activityontheS/GBlowdownLoop"B"piping(2")andComponent Supportsinsidecontainment wasinitiated.
PipingmaterialwasupgradedfromCarbonSteeltoChrome-Moly.
Thisactivitywascontrolled byWOg19500287, TSR94-116, EWR4499andSM94-116.1.
Construction CodeVT&MTexaminations onthe2"SocketWeldsaswellasRT&VTexaminations ontheone(1)ButtWeldwereperformed andacceptable.
ExistingComponent Supports(BDU-5,BDU-11,BDU-15,&BDU-16)wereremovedforthisactivityandlaterreinstalled hadConstruction CodeVTexaminations performed andacceptable.
AnASMESection.XILeakageexamination wasperformed andacceptable inaccordance withCodeCaseN-416.24 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, secondPeriod,ThirdOutage(1995)ATTACHMENT IIIEROSION/CORROSION (MINWALL)
PROGRAMSUMMARYThissectionprovidesErosion/Corrosion examination detailsandinformation corresponding toitemsinspected duringthe1995Outage.Atotalof96itemswereexamined.
Thebreakdown ofthistotalisasfollows:ComonentTeTotalNumberPipesElbowsReducersTeesExansionJointTotal513464196Thefollowing listsidentifies systemsofexaminedcomponents, systemcomponent resultsummaries, andcomponent resultdetails.SstemsofExaminedComonents:Component thickness measurements wereperformed onthefollowing systems.DWGNO.SYSTEMSM-1M-2M-4AM-4BM-7AM-10M-10AM-10BM-10CM-11AM-15AM-15BA/BF.W.PUMPDISCHARGE TO5A/BHEATERS5A/BF.W.HEATERSTOF.W.HEADERFEEDWATER CLEANUPTOCONDENSER FROM5A/BHPHEATERSFEEDWATER CLEANUPTOCONDENSER
&CONDENSATE DEM.RINSEHEATERDRAINTANKDISCHARGE LOWPRESSUREDOWNCOMERS (WESTCONDENSER)
LOWPRESSUREDOWNCOMERS TOL.P.H.(WESTCONDENSER)
LOWPRESSUREDOWNCOMERS (EASTCONDENSER)
LOWPRESSUREDOWNCOMERS TOL.P.H.(EASTCONDENSER)
MSR1A&1B2NDPASSDRAINMSR1A4THPASSTO5AHEATERMSR1B4THPASSTO5AHEATER 00 REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIISstemsofExaminedComonents:Cont.DWGNO.SYSTEMSM-16M-31M-41AM-41BM-75M-81M-88DM-90M-91M-105MSR1A&1B4THPASSTOCONDENSER MSR1A&1BTOHEATERDRAINTANK&CONDENSER 5AHPHEATERDRAINTO4ALPHEATER5BHEATERDRAINTO4BHEATERSTEAMEXTRACTION TO5A&5BHEATERSFEEDWATER DISCHARGE (TURBINEBLDG)S/GBLOWDOWNTOFLASHTANK(TURBINEBUILDING)
FEEDWATER CLEANUP(CV-18)FEEDWATER CLEANUP(CV-19)HEATINGSTEAMSstemComonentResultSummaries:
Thefollowing breakdownbysystemprovidesgeneralresultsonthecomponent typesthatwereexamined.
DWGNO.SYSTEMM-1A/BFoWPUMPDISCHARGE TO5A/BHEATERSComponents Examined:
Results:4ofNominal2Elbows4Acceptable 2PipesM-25A/BF.W.HEATERSTOFW.HEADERComponents Examined:
Results:4ofNominal2Elbows1Acceptable 2Pipes3>88 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIISstemComonentResultSummaries:
Cont.DWGNO.SYSTEMM-4AFEEDWATER CLEANUPTOCONDENSER FROM5A/BHPHEATERSComponents Examined:'esults:
4ofNominal1Pipe1>88M-4BFEEDWATER CLEANUPTOComponents Examined:
2Elbows2Pipes2ReducerCONDENSER
&CONDENSATE DEM.RINSEResults:>ofNominal2>88288-82182-76176-70M-7AHEATERDRAINTANKDISCHARGE Components Examined:
Results:4ofNominal2Elbows1Acceptable 1Expansion Joint4>881Pipe1ReducerM-10LOWPRESSUREDOWNCOMERS (WESTCONDENSER)
Components Examined:
Results:4ofNominal1Pipe1<65M-10ALOWPRESSUREDOWNCOMERS TOL.PH(WESTCONDENSER)
Components Examined:
Results:4ofNominal5Pipes182-764<65M-10BLOWPRESSUREDOWNCOMERS (EASTCONDENSER)
Components Examined:
Results:%ofNominal1Pipe1<65M-10CLOWPRESSUREDOWNCOMERS TOL.P.H(EASTCONDENSER)
Components Examined:
Results:~ofNominal3Pipes170-652<65
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)/ATTACHMENT IIISstemComonentResultSummaries:
Cont.DWG~NO.SYSTEMM-11AMSR1A&1B2NDPASSDRAINComponents Examined:
Results:9ofNominal1Elbow2>881PipeM-15AMSR1A4THPASSTO5AHEATERComponents Examined:
Results:4ofNominal4Elbows10>885Pipes1TeeM-15BMSR1B4THPASSTO5AHEATERComponents Examined:
Results:4ofNominal1Elbow1>88M-16MSR1A&1B4THPASSTOCONDENSER Components Examined:
Results:4ofNominal1Pipe188-82M-31MSR1A&1BTOHEATERDRAINTANK&CONDENSER Components Examined:
Results:4ofNominal5Elbows13>887Pipes1TeeM-41A5AHPHEATERDRAINTO4ALPHEATERComponents Examined:
Results:%ofNominal3Elbows5>882PipesM-41BSBHEATERDRAINTO4BHEATERComponents Examined:
Results:4ofNominal3Elbows4>882Pipes188-82 R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeri.od,ThirdOutage'(1995)
ATTACHMENT IIISstemComonentResultSummaries:
Cont.DWG~NOSYSTEMM-75STEAMEXTRACTION TO5AComponents Examined:
2Elbows3Pipes1Tee5BHEATERSResults:cofNominal1Acceptable 1Unacceptable 2>88176-70170-65M-81FEEDWATER DISCHARGE (TURBINEBLDG)Components Examined:
Results:4ofNominal2Elbows5>883Pipes188-822Reducers1<65M-88D'S/G BLOWDOWNTOFLASHComponents Examined:
2Elbows6Pipes1TeeTANK(TURBINEBUILDING)
Results:4ofNominal7>88176-701<65M-90FEEDWATER CLEANUP(CV-18)Components Examined:
Results:4ofNominal1Elbow182-761Pipe176-70M-91FEEDWATER CLEANUP(CV-19)Components Examined:
Results:4ofNominal1Elbow1>881Reducer188-82M-105HEATINGSTEAMComponents Examined:
1Elbow2PipesResults:4ofNominal3>88 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)/ATTACHMENT IIIComanentResultDetails:Thefollowing listprovidesexamination resultdetailsoncomponents
,bydrawingnumberandsystemdescription.
The."Component Type"classification specified inthelistbelowcorresponds tothefollowing:
P=PipeR=Reducer/Expander E=ElbowT=TeeJ=Expansion JointDrawingNo.M-1System:A/BFWPUMPDISCHARGE TO5A/BHEATER-.SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth200270272002802820030030P0.938E0.938P0.938E0.9380.604NA>880.703NA>880.604NA>880.701NA>88VTVTVT'DrawingNo.M-2System:5A/BFEEDWATER HEATERSTOFEEDWATER HEADERSummaryNumberComp.Comp.NominalNominalIDTeWall1Wall2MinimumMinimumPercentNDEAllowable ReadinNominalMeth20113013201140142011501520116016E0.938P0.938E0.938E0.9380.7050.7100.961>881.009>88UTUT0.704NA>88VT0.6050.864>88UTDrawingNo.M-4ASystem:FEEDWATER CLEANUPTOCONDENSER/EAST WALLSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth20331031P0.5000.2500.603>88UT RE~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriodiThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-4BSystem:FEEDWATER CLEANUPTOCONDENSER/EAST WALLSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth20451051R0.5000.5940.350,0.416 0.49188-82UT2045205220459059204600602046306320464064E0.594E0.594P0.594R0.594P0.6880.6880.4160.571>88UT0.416,0.482 0.46776-70UT0.4820.675>88UT0.4160.50388-82UT0.4160.467.82-76UTDrawingNo.M-7ASystem:HEATERDRAINTANKDISCHARGE
~~~~~~SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth2070100120702002E0.688P0.68820703003E0.68820704504AJ0.68820705005R0.6880.7500.2780.2740.2780.695>88UT0.646>880.630>88UTUTVTUTNANA0.278,0.303 0.786>88DrawingNo.M-10System:LOWPRESSUREDOWNCOMERS SummaryNumberComp.Comp.NominalNominalMinimumIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth2110601FP0.3750.1130.236(65UT
R.E.GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-10ASystem:STEAMEXTRACTION TO2ALPHSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth2121801821219019212250252122602621227027P0.375P0.375P0.375P0.375P0.3750.1130.150<65UT0.1130.1130.156<65UTHoles<65UT0.1130.140<65UT0.1130.28582-76.UTDrawingNo.M-10BSystem:LOWPRESSUREDOWNCOMERS tSummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth2130602FP0.3750.1130.159<65UTDrawingNo.M-10CSystem:STEAMEXTRACTION TO2BLPHSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDE~NumberIDTeWall1Wall2Allowable ReadinNominalMeth214130132141401421415015P0.375P0.375P0.3750.1130.1130.1130.120<65Holes<65UTUT0.25470-65UTDrawingNo.M-11ASystem:MSR1A&1B2NDPASSDRAINSSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth21508008E0.4320.2680.390>88UT21509009P0.4320.2670.401>88UT
REGINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)/ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-15ASystem:MSR1A4THPASSTOHEATER5ASummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth22601001226020022260252A22603003P0.432E0.432P0.432E0.43222610510AE0.3002261101122612012T0.300P0.30022604004P0.43222609009E0.30022610010-P0.3000.2660.2660.2660.2660.2660.1710.1680.1750.1710.1680.499>880.385>880.398>880.397>880.390>880.284>880.275>880.266>880.289>880.284>88UTUTUTUTUTUTUTUTUTDrawingNo.M-15BSystem:MSR1B4THPASSTOHEATER5B,SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth22721073E0.3000.1690.273>88UTDrawingNo.M-16System:MSR1A&1B4THPASSDRAINTOCONDENSER SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth22801001P0.3000.1680.26388-82UT R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)1ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-31System:MSR1A&1BTOHEATERDRAINTANKSummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth'602502526026026e260270,272602802826028128A26028228B2'6028328C26037037E0.432P0.432T0.432P0.432E0.432P0.432E0.432P0.43226009009E0.43226010010P0.43226011011E0.43226012012P0.43226024724CP0.4320.1680.1660.168,0.1660.3780.3780.3780.3780.3780.3780.3780.3780.3780.473>880.417.>880.414>880.418>880.403>880.420>880.412>880.448>880.390>880.387>88UTUTUTUTUTUTUTUTUT0.408>88UT0.388>88UT0.419>88UTDrawingNo.M-41ASystem:5AH.P.H.DRAINTO4AL.P.H.SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth2900121A2900131C2900141D2900151E2900171FE0.687E0.687P0.432E0.432P0.4320.4320.6010.688>880.3780.3780.3780.412>880.417>880.411>880.601,0.378 0.678>88UTUTUTUT,UT10 R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, secondPeriodIThirdOutage(1995)/ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-41B8ystem:5BH.P.H.DRAINTO4BL.P.H.SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth-291012"40AE0.68729101340CE0.68729101440DP0'.43229101540EE0.43229101640FP0.4320.4320.6010.656>88UTUTUT0.3780.3780.406>88UT0.38088-82UT0.601;0.378 0.621>880.3780.418>88DrawingNo.M-75System:STEAMEXTRACTION TO5A&5BH.P.H.~~~~SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth3031201230313013303140143031501530317017P0.375E0.375E0.375P0.375T0.37530320520AP0.3750.2320.2310.2250.2140.2300.2300.26476-70UT0.353>88UTNAOKVTNAOKVT0.367>88UT0.25470-65UTDrawingNo.M-81System:FEEDWATER DISCHARGE SummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth39009009P0.93839006006R0.8440.93839006506AP0.9380.6970.7100.6050.848>88UT0.954>880.863>88UTUT0.570,0.705 0.475<65UT11 R.EGINNANUCLEARPOWERPLANTrInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:DrawingNo.M-81(Cont.)SummaryComp.Comp.NominalNumberIDTeWall1Cont.NominalMinimumWall2Allowable MinimumPercentNDEReadinNominalMeth390210213902302339024024R0.844E0.938P0.9380.9380.6970.6050.855>880.875>88UTUT0.637,0.699 0.72088-82UTDrawingNo.M-88DSystem:BLOWDOWNTOBLOWDOWNTANK(TURBINEBLDG.)SummaryComp.Comp.NominalNominalMinimumMinimumPercentNDENumberIDTeWall1Wall2Allowable ReadinNominalMeth38514014P0.30038515015E0.30038516016P0.300385392,.39BP0.33738553053P0.30038554054E0.30038555055P0.30038575775BP0.33738580080T0.5000.5000.1700.1700.1680.1440.1700.1700.1680.1690.291>88UT0.284>88UT0.297>88UT0.25176-70UT0.283>880.291>880.284>880.303>88UTUTUTUTUT0.285,0.258 0.265<65DrawingNo.M-90System:FWRECIRCCV-18SummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth.30041040E0.43230044043P0.4320.3340.2870.34082-76UT0.31776-70UT12
.i~R.E~GINNANUCLEARPOWERPLANTInservice Inspection Report1990-1999
- Interval, SecondPeriod,ThirdOutage(1995)ATTACHMENT IIIComonentResultDetails:Cont.DrawingNo.M-91System:FWRECIRCCV-19SummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercent'NDE ReadinNominalMeth30079033R0~3370~4320~223I0~3380~342>88UT30082036E0.4320.3330.37488-82UTDrawingNo.M-105System:HouseHeatingSystemSummaryComp.Comp.NominalNominalMinimumNumberIDTeWall1Wall2Allowable MinimumPercentNDEReadinNominalMeth33102002E0.237P0.23733101001P0.2370.1660.1660.1660.223>880.240>880.218>88UTUTUT13