#REDIRECT [[IR 05000325/2003008]]
{{Adams
| number = ML042160062
| issue date = 08/02/2004
| title = IR 05000324-03-008, Notification of Brunswick, Unit 2, Supplemental Inspection During Week of 08/23/2004
| author name = Fredrickson P
| author affiliation = NRC/RGN-II/DRP/RPB4
| addressee name = Gannon C
| addressee affiliation = Carolina Power & Light Co
| docket = 05000324
| license number = DPR-062
| contact person =
| document report number = IR-03-008
| document type = Inspection Report, Letter
| page count = 5
}}
 
{{IR-Nav| site = 05000324 | year = 2003 | report number = 008 }}
 
=Text=
{{#Wiki_filter:ust 2, 2004
 
==SUBJECT:==
NOTIFICATION OF BRUNSWICK STEAM ELECTRIC PLANT UNIT 2 SUPPLEMENTAL INSPECTION - NRC INSPECTION REPORT 50-325/2003-08 AND 50-324/2003-08
 
==Dear Mr. Gannon:==
In a Final Significance Determination letter, dated June 2, 2004, from Mr. Loren Plisco, the Region II Deputy Regional Administrator, you were informed that the NRC had concluded that the final significance determination of a Brunswick Steam Electric Plant Unit 2 finding associated with an emergency diesel generator jacket water cooling system leak, had been characterized as White (i.e., an issue of low to moderate safety significance, which may require additional NRC inspection). Also in this letter you were informed that, because Brunswick Unit 2 plant performance for this issue had been determined to be in the increased regulatory response band, we would use the NRC Action Matrix to determine the most appropriate NRC response for the finding, and notify you by separate correspondence of our determination.
 
The purpose of this letter is to notify you that we plan to conduct a Supplemental Inspection of Brunswick Unit 2 during the week of August 23, 2004. The inspection will be conducted by Mr.
 
Bob Hagar, the Senior Resident Inspector at the H. B. Robinson Nuclear Plant. In accordance with NRC Inspection Manual Chapter 0305, Operating Reactor Assessment Program, the inspection will be conducted using NRC Inspection Procedure 95001, Inspection For One Or Two White Inputs In A Strategic Performance Area.
 
Discussions between Mr. Eugene DiPaolo of my staff and Mr. Steve Tabor of your staff have taken place to allow for scheduling conflicts and personnel availability to be resolved in advance of this inspection. Thank you for your cooperation in this matter. If you have any questions regarding the inspection, please contact Mr. Hagar at (843) 383-4571 or me at (404)
562-4530.
 
CP&L    2 In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room (PDR) or from the NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
 
Sincerely,
/RA/
Paul E. Fredrickson, Chief Reactor Projects Branch 4 Division of Reactor Projects Docket No.: 50-324 License No: DPR-62 cc: (See page 3)
 
CP&L  3 cc:
W. G. Noll, Director Site Operations Margaret A. Force Brunswick Steam Electric Plant Assistant Attorney General Carolina Power & Light Company State of North Carolina Electronic Mail Distribution Electronic Mail Distribution David H. Hinds, Plant Manager Jo. A. Sanford, Chair Brunswick Steam Electric Plant North Carolina Utilities Commission Carolina Power & Light Company c/o Sam Watson, Staff Attorney Electronic Mail Distribution Electronic Mail Distribution James W. Holt, Manager  Robert P. Gruber Performance Evaluation and Executive Director Regulatory Affairs PEB 7 Public Staff NCUC Carolina Power & Light Company 4326 Mail Service Center Electronic Mail Distribution Raleigh, NC 27699-4326 Edward T. O'Neil, Manager Public Service Commission Site Support Services  State of South Carolina Brunswick Steam Electric Plant P. O. Box 11649 Carolina Power & Light Company Columbia, SC 29211 Electronic Mail Distribution David R. Sandifer, Chairperson Leonard R. Beller, Supervisor Brunswick County Board of Commissioners Licensing/Regulatory Programs P. O. Box 249 Brunswick Steam Electric Plant Bolivia, NC 28422 Carolina Power & Light Company Electronic Mail Distribution Warren Lee, Director New Hanover County Department of William D. Johnson  Emergency Management Vice President & Corporate Secretary P. O. Box 1525 Carolina Power & Light Company Wilmington, NC 28402-1525 Electronic Mail Distribution Distribution w/encl: (See page 4)
John H. O'Neill, Jr.
 
Shaw, Pittman, Potts & Trowbridge 2300 N Street NW Washington, DC 20037-1128 Beverly O. Hall, Section Chief Division of Radiation Protection N. C. Department of Environment and Natural Resources Electronic Mail Distribution
 
Distribution w/encl:
B. Mozafari, NRR L. Slack, RII EICS RIDSRIDSNRRDIPMLIPB R. Hagar, RII PUBLIC OFFICE DRP/RII SIGNATURE PEF NAME PFredrickson:as DATE  08/02/2004 E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO YES NO PUBLIC YES NO OFFICIAL RECORD COPY DOCUMENT NAME: E:\Filenet\ML042160062.wpd
}}

Latest revision as of 00:47, 17 March 2020

IR 05000324-03-008, Notification of Brunswick, Unit 2, Supplemental Inspection During Week of 08/23/2004
ML042160062
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 08/02/2004
From: Fredrickson P
NRC/RGN-II/DRP/RPB4
To: Gannon C
Carolina Power & Light Co
References
IR-03-008
Download: ML042160062 (5)


Text

ust 2, 2004

SUBJECT:

NOTIFICATION OF BRUNSWICK STEAM ELECTRIC PLANT UNIT 2 SUPPLEMENTAL INSPECTION - NRC INSPECTION REPORT 50-325/2003-08 AND 50-324/2003-08

Dear Mr. Gannon:

In a Final Significance Determination letter, dated June 2, 2004, from Mr. Loren Plisco, the Region II Deputy Regional Administrator, you were informed that the NRC had concluded that the final significance determination of a Brunswick Steam Electric Plant Unit 2 finding associated with an emergency diesel generator jacket water cooling system leak, had been characterized as White (i.e., an issue of low to moderate safety significance, which may require additional NRC inspection). Also in this letter you were informed that, because Brunswick Unit 2 plant performance for this issue had been determined to be in the increased regulatory response band, we would use the NRC Action Matrix to determine the most appropriate NRC response for the finding, and notify you by separate correspondence of our determination.

The purpose of this letter is to notify you that we plan to conduct a Supplemental Inspection of Brunswick Unit 2 during the week of August 23, 2004. The inspection will be conducted by Mr.

Bob Hagar, the Senior Resident Inspector at the H. B. Robinson Nuclear Plant. In accordance with NRC Inspection Manual Chapter 0305, Operating Reactor Assessment Program, the inspection will be conducted using NRC Inspection Procedure 95001, Inspection For One Or Two White Inputs In A Strategic Performance Area.

Discussions between Mr. Eugene DiPaolo of my staff and Mr. Steve Tabor of your staff have taken place to allow for scheduling conflicts and personnel availability to be resolved in advance of this inspection. Thank you for your cooperation in this matter. If you have any questions regarding the inspection, please contact Mr. Hagar at (843) 383-4571 or me at (404)

562-4530.

CP&L 2 In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room (PDR) or from the NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Paul E. Fredrickson, Chief Reactor Projects Branch 4 Division of Reactor Projects Docket No.: 50-324 License No: DPR-62 cc: (See page 3)

CP&L 3 cc:

W. G. Noll, Director Site Operations Margaret A. Force Brunswick Steam Electric Plant Assistant Attorney General Carolina Power & Light Company State of North Carolina Electronic Mail Distribution Electronic Mail Distribution David H. Hinds, Plant Manager Jo. A. Sanford, Chair Brunswick Steam Electric Plant North Carolina Utilities Commission Carolina Power & Light Company c/o Sam Watson, Staff Attorney Electronic Mail Distribution Electronic Mail Distribution James W. Holt, Manager Robert P. Gruber Performance Evaluation and Executive Director Regulatory Affairs PEB 7 Public Staff NCUC Carolina Power & Light Company 4326 Mail Service Center Electronic Mail Distribution Raleigh, NC 27699-4326 Edward T. O'Neil, Manager Public Service Commission Site Support Services State of South Carolina Brunswick Steam Electric Plant P. O. Box 11649 Carolina Power & Light Company Columbia, SC 29211 Electronic Mail Distribution David R. Sandifer, Chairperson Leonard R. Beller, Supervisor Brunswick County Board of Commissioners Licensing/Regulatory Programs P. O. Box 249 Brunswick Steam Electric Plant Bolivia, NC 28422 Carolina Power & Light Company Electronic Mail Distribution Warren Lee, Director New Hanover County Department of William D. Johnson Emergency Management Vice President & Corporate Secretary P. O. Box 1525 Carolina Power & Light Company Wilmington, NC 28402-1525 Electronic Mail Distribution Distribution w/encl: (See page 4)

John H. O'Neill, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N Street NW Washington, DC 20037-1128 Beverly O. Hall, Section Chief Division of Radiation Protection N. C. Department of Environment and Natural Resources Electronic Mail Distribution

Distribution w/encl:

B. Mozafari, NRR L. Slack, RII EICS RIDSRIDSNRRDIPMLIPB R. Hagar, RII PUBLIC OFFICE DRP/RII SIGNATURE PEF NAME PFredrickson:as DATE 08/02/2004 E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO YES NO PUBLIC YES NO OFFICIAL RECORD COPY DOCUMENT NAME: E:\Filenet\ML042160062.wpd