ENGINE SYSTEMS, INC.

175 Freight Road, Rocky Mount, NC 27804

' I

\\

Telephone: 252/977-2720 Fax: 252/446-1134 Report No.

10CFR21-0135 Rev. 0:

05/24/23 1 0CFR21 R_~/PClRTING OF DEFECTS AND NIO~-COMPLIANCE l *

t.

COMPONENT:

Woodward EGB-35P GLO"fl/ir/Actuator with Foreign Material Part Number 9903-722 Serial Number 18847017 SYSTEM:

Emergency Diesel Generator CONCLUSION:

Reportable in Accordance With 1 0CFR21

~~~~---~~-~----------

Qngineering Manager Reviewed By: ----~---fMrl=-.........a-=-------

Quality Manager Quality Performance With Pride Date:

ENGINE SYSTEMS, INC.

175 Freight Road Rocky Mount, NC 27804 May 24, 2023 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

1 0CFR21 Reporting of Defects and Non-Compliance -

Telephone: 252/977-2720 Fax: 252/446-1134

~o _, lZL(

'[ib -- 7 Z-5 Engine Systems, Inc. Report No. 1 0CFR21-0135, Rev. 0 Woodward EGB-35P Governor/Actuator with Foreign Material Part Number 9903-722 SeriaINumber18847017

Dear Sir/ Madam:

The enclosed report addresses a reportable notification on a Woodward EGB-35P governor/actuator with foreign material, !if~ 9903-722, S/N 18847017.

l

.\\

I '

A copy of the report has also been mailed tc our affected nuclear customer.

i*

Please sign below, acknowledging receip. n: this report, and return a copy to the attention of Document Control at the add esS above (or, fax to number 252/446-3830) within 10 working days after receipt.

Yours very truly, ENGINE SYSTEMS, INC.

I Susan Woolard Document Control Coordinator Please let us know if ANY of your mailing ~nformation changes - name of recipient, name of company/facility, address, etc. Mark the changes on this acknowledgment form and send to us by mail or FAX to the number above.

RECEIVED: ---------

71 DATE:

Quality Performance With Pride

Report No.

10CFR21-0135 Record of Revisions Page:

1 of 1 REV DATE PAGE DESCRIPTION 0

05/24/23 Original Issue.

Report No.

Revision:

Date:

Page:

Pursuant to 10 CFR 21.21(d)(4), ESI is presenting the required information as follows:

(i) Name and address of the individual or individuals informing the Commission.

Dan Roberts John Kriesel Quality Manager Engineering Manager Engine Systems Inc.

Engine Systems Inc.

175 Freight Rd.

175 Freight Rd.

Rocky Mount, NC 27804 Rocky Mount, NC 27804 10CFR21-0135 0

05/24/23 1 of 2 (ii) Identification of the basic component supplied within the United States which fails to comply or contains a defect.

Woodward Governor, PIN 9903-722, SIN 18847017 (iii) Identification of the firm supplying the basic component which fails to comply or contains a defect.

Engine Systems Inc. (ES/)

(iv) Nature of the defec~ or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

An EGB-35P governor/actuator (governor) installed on a customer's emergency diesel generator failed soon after installation. Investigation_ revealed a piece of foreign material, a loose buffer plug, inside the governor that caused the failure. Since the governor is used to maintain fuel rack position of the diesel engine, failure of the governor would prevent the emergency diesel generator set from performing during a safety-event.

(v} The date on which the information of such defect or failure to comply was obtained.

March 28, 2023 (vi) In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.

Customer Customer ES/Sales Part Serial ESI C-of-C PO Order Number Number Date Duke Energy-00655050 8002096 9903-722 18847017 06/30/2015 Brunswick Nuclear Plant Table 1: EGB-35P Governor/Actuator Affected by Foreign Material (vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.

For Brunswick Nuclear Plant:

No action required. The affected governor has been returned to ES/.

For ES/:

The governor will be refurbished under ESl's 10CFR50 Appendix B program and certified for continued use at Brunswick Nuclear Plant. To prevent reoccurrence, ES/ will revise the dedication requirements to enhance existing foreign material inspection practices to include a visual inspection where the buffer plug was located within the governor. The revisions are expected to be complete within 30 days but in all cases prior to future shipments.

Report No.

Revision:

Date:

Page:

1 0CFR21-0135 0

05/24/23 2 of2 (viii) Any advice related to the potential defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.

The governor uses a buffer plug to retain the buffer piston and springs in the subgovernor case. All components required of the governor assembly were accounted for; the buffer plug discovered inside the governor was an extra component. Circumstances during original dedication activities in 2015 required disassembly of the governor. It was during this process the additional buffer plug was introduced into the governor. The governor tested satisfactorily and remained operable until the cumulative effect of contact between the metal buffer plug and internal governor gearing produced metal shavings (additional foreign material) of a sufficient amount to cause failure of the governor.

\\

'