No. 01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING Licensee: .        AmerGen Energy Company, LLC Facility:          Oyster Creek Nuclear Generating Station Docket No:          05000219 Time and Date:      Friday, August 3, 2001, at 10:00 a.m.
No. 01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING Licensee: .        AmerGen Energy Company, LLC Facility:          Oyster Creek Nuclear Generating Station Docket No:          05000219 Time and Date:      Friday, August 3, 2001, at 10:00 a.m.
Location:          U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415 Purpose:           A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.
Location:          U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415
 
==Purpose:==
A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.
NRC Attendees:      J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)
NRC Attendees:      J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)
J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)
J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)
Line 515: Line 518:


No. 01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING Licensee:          AmerGen Energy Company, LLC Facility:          Oyster Creek Nuclear Generating Station Docket No:          05000219 Time and Date:      Friday, August 3, 2001, at 10:00 a.m.
No. 01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING Licensee:          AmerGen Energy Company, LLC Facility:          Oyster Creek Nuclear Generating Station Docket No:          05000219 Time and Date:      Friday, August 3, 2001, at 10:00 a.m.
Location:          U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415 Purpose:           A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.
Location:          U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415
 
==Purpose:==
A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.
NRC Attendees:      J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)
NRC Attendees:      J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)
J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)
J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)

Latest revision as of 04:34, 24 December 2019

E-mail Correspondence Between NRC and Rge from June 12 to June 29, 2001
ML012000255
Person / Time
Site: Ginna Constellation icon.png
Issue date: 07/18/2001
From: Doerflein L
NRC Region 1
To:
NRC Region 1
References
-RFPFR IR-01-005
Download: ML012000255 (138)


Text

    • MEMORANDUM**

TO: Public Docket Room FROM: Lawerence T. Doerflein, Chief Systems Branch Cý;IaA"ýýý

SUBJECT:

E-MAIL CORRESPONDENCE BETWEEN NRC AND RGE FROM JUNE 12 TO JUNE 29, 2001 Attached to this memo are a series of email correspondense that took place between the NRC and Rochester Gas and Electric (RGE) personnel from the R.E. Ginna Nuclear Power Plant between June 12 to June 29, 2001. The information contained within these e-mails was used during the course of an NRC baseline inspection, which will be documented in NRC inspection report 05000244/2001005.

Attachments: 1. June 12, 2001 Email From NRC To RGE,

Subject:

Loss of SW SDP

2. June 13, 2001 Email From RGE To NRC,

Subject:

Loss of SW SDP

3. June 18, 2001 Email From NRC To RGE,

Subject:

Loss of SW SDP

4. June 22, 2001 Email From RGE To NRC,

Subject:

NRC Questions

5. June 29, 2001 Email From RGE To NRC,

Subject:

Loss of SW SDP

ATTACHMENT I June 12, 2001 Email From NRC To RGE,

Subject:

Loss of SW SDP

Mail Envelope Properties (3B266CAB.8A6: 10: 35430)

Subject:

Re: Loss of SW SDP Creation Date: 6/12/01 3:25PM From: Wayne Schmidt Created By: WLS@nrc.gov Recipients nrc.gov kplpo.KPDO AXL CC (Alfred Lohmeier)

FJA CC (Frank Amer)

GWM2 CC (George Morris)

MCM CC (Michael Modes)

PDK CC (Paul Kaufman)

SMP CC (Stephen Pindale) rge.com ThomasHarding (ThomasHarding@rý,*.com)

Post Office Route kp lpo.KPDO nrc.gov rge.com Files Size Date & Time MESSAGE 5965 06/12/01 03:25PM Options Expiration Date: None Priority: Standard Reply Requested: No Return Notification: None Concealed

Subject:

No Security: Standard

From: Wayne Schmidt To: Thomas_-Harding@rge.com Date: 6/12/01 3:25PM

Subject:

Re: Loss of SW SDP Hi Tom - just a few thoughts from a team meeting we had today.

1) We would like to know the basis for the operator failure rates quoted in the previous e-mail.
2) We are unable to find a procedure that directs the use of the city water to SAFW following a LOSW if the CST is not depleted. (i.e.,no step in ATT-5.1 to verify the avavability of the SW

,suction source or lineup city water)

3) The loss of IA procedure does cross tie to SA - so feed and bleed appear to apply.
4) Is there a cross tie from city water to the firemain in the IB, if so what directs its use?

>>> <ThomasHarding@rge.com> 06108/01 02:09PM >>>

FYI, here is a little more info from Mark. Both of us will be unavailable on Monday, and Mark will also be gone Wed. through Friday. Tuesday is good for both of us.

- - Forwarded by Thomas Harding/NOG/RG&E on 06/0812001 02:07 PM --------------

Mark Flaherty 06/08/2001 01:00 PM To: Thomas Harding/NOG/RG&E@RG&E cc:

Subject:

Loss of SW SDP Since I will only be in the office on Tues next week, I performed an additional review of the SDP as sent by the NRC on 12/29/00 related to the loss of SW procedure issue identified in the NRC inspection. Based on this, I would like to offer the following:

Event Tree 10 (LSSW) is missing all feed and bleed (F&B) functions.

This apparently was done on the premise that F&B requires SI, PORVs, and all supporting functions. SI has no SW dependencies as described in the PSA Final Report (Section 6.17.4.d) and the Ginna UFSAR (Section 6.3.2.2.2.1). At the time the event trees were being developed, there was some question about whether the PORVs, on nitrogen only, was sufficient for F&B. RG&E agreed that it was not and the PSA now requires IA in addition to nitrogen for F&B purposes. Table 2 of the 12/29/00 SDP identifies through Note 8 that the Service Air compressor is air cooled and does not require SW. Therefore, F&B should be

considered for the LSSW event tree (and for the for loss of CCW tree).

I would imagine this would would have a large effect on the results.

The SDP Worksheet for loss of SW (Table 3.12) identifies a failure rate of 0.1 for the operators to align city water to the SAFW system and to provide fire water to the TDAFW lube oil cooler. The PSA currently uses 1.OOE-02 and 6.70E-03 for these events, respectively (or at least one order of magnitude lower). However, the following things should be pointed out:

If all SW is lost, then fire water to the TDAFW pump is likely lost since they take suction from a similar location. City water to SAFW would remain available since this is a different source. The PSA reflects this by the fact that event SWCXXSUCTN, TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION fails both SW and the fire water pumps.

This event forms the basis for most of the frequency of losing all SW as an initiator (versus the random failure of 4 SW pumps).

The PSA operator failure rates are based on losing all AFW at the start of the transient. If the TDAFW pump runs for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> before failing, there is a lot of additional time before SG tube uncovery that would lead to a more likely operator success.

I hope these help.

CC: GINNASSDI

ATTACHMENT 2 June 13, 2001 Email From RGE To NRC,

Subject:

Loss of SW SDP

Mail Envelope Properties (3B276D56.8F8 :13 : 6392)

Subject:

Re: Loss of SW SDP Creation Date: 6/13/01 9:39AM From: <ThomasHarding@rge.com>

Created By: ThomasHarding@rge.com Recipients nrc.gov kplpo.KP DO WLS (Wayne Schmidt)

Post Office Route kplpo.KPDO nrc.gov Files Size Date & Time MESSAGE 1557 06/13/01 09:39AM 3-16-4-1.1 26167 Header 1004 Options Expiration Date: None Priority: Standard Reply Requested: No Return Notification: None Concealed

Subject:

No Security: Standard

From: <ThomasHarding@rge.com>

To: 'Wayne Schmidt" <WLS@nrc.gov>

Date: 6/13/01 9:41AM

Subject:

Re: Loss of SW SDP

1) I'm e-mailing the info that Mark provided, any detailed discussion of this should probably wait until next week.
2) The lineup is controlled by ER-AFW.1, which is entered from about a bazzilion EOPs. I'll assume that you still have a copy of this. The procedure is intended to give the Operators many options in getting water into the steam generators. To some degree you need to rely on RO/SRO training.
3) no response requested.
4) I attached procedure SC-3.16.4.1 (it's in WordPerfect). This procedure is utilized by Operations anytime there is major maintenance of the fire system (like today!).

(See attached file: 3-16-4-1.1)

"Wayne Schmidt" <WLS@nrc.gov> on 06/12/2001 03:25:31 PM To: <ThomasHarding@rge.com>

cc: "Alfred Lohmeier" <AXL@nrc.gov>, "Frank Arner" <FJA@nrc.gov>, "George Morris" <GWM2@nrc.gov>, "Michael Modes" <MCM@nrc.gov>, "Paul Kaufman"

<PDK@nrc.gov>, "Stephen Pindale" <SMP@nrc.gov>

Subject:

Re: Loss of SW SDP Hi Tom - just a few thoughts from a team meeting we had today.

1) We would like to know the basis for the operator failure rates quoted in the previous e-mail.
2) We are unable to find a procedure that directs the use of the city water to SAFW following a LOSW if the CST is not depleted. (i.e.,no step in ATT-5.1 to verify the avavability of the SW suction source or lineup city water)
3) The loss of IA procedure does cross tie to SA - so feed and bleed appear

to apply.

4) Is there a cross tie from city water to the firemain in the IB, if so what directs its use?

ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER PROCEDURE NO. SC-3.16.4.1 REV. NO. 9 CROSS TIE OF DOMESTIC WATER SUPPLY TO FIRE SERVICE WATER SYSTEM RESPONSIBLE MANAGER EFFECTIVE DATE GINNA STATION UNIT #1 COMPLETED DATE:

TIME:

CATEGORY 1.0 REVIEWED BY:

THIS PROCEDURE CONTAINS 7 PAGES

SC-3.16.4.1: 2 Rev. 9 SC-3.16.4.1 CROSS TIE OF DOMESTIC WATER SUPPLY TO FIRE SERVICE WATER SYSTEM 1.0 PURPOSE 1.1 To provide adequate water supplies to the on-site fire service water system header in the event of a loss of the Electric and Diesel Fire Pumps or as directed by the Site Fire Protection Engineer/Designee and Shift Supervisor.

1.2 To provide instructions to site personnel regarding the proper method of completing the cross connection.

1.3 To prevent cross contamination between the on-site fire service water system and the potable domestic water system supplied by the Ontario Water Authority.

2.0 REFERENCES

2.1 GAI Drawing # D-381-301.

2.2 GAI Drawing # D-381-302.

3.0 INSTRUCTIONS 3.1 Obtain permission from Shift Supervisor to perform this procedure.

3.1.1 Contact Maintenance and Fire Protection and Safety for equipment and support.

3.2 At Domestic Hydrant #7 remove both 2.5" discharge caps. Tighten large discharge cap.

3.2.1 Open hydrant fully and allow a full flow of water to flush main of any foreign matter.

3.2.2 Shut down hydrant and place a 2.5" gate valve on each discharge port, then connect approximately 100' of 3" fire hose to each gate valve.

NOTE All connections to yard hydrants shall utilize gated valve devices for quick isolation and personnel safety purposes.

SC-3.16.4.1: 3 Rev. 9

SC-3.16.4.1: 4 Rev. 9 3.2.3 Route hose to wall valve #5158. Place back flow protectors on each input point. Be sure flow of water is from yard hydrant to wall hydrant.

3.2.4 Connect fire hose to back flow protectors.

3.2.5 Open hydrant #7 slowly and completely.

3.2.6 Open hydrant gate valves slowly and completely.

3.2.7 Once pressure has equalized between hydrant and hose, open valve #5158 fully.

3.2.8 Inspect hose and connections for any signs of leakage.

3.3 At domestic fire hydrant #8, remove both 2.5" discharge caps. Tighten large discharge cap.

3.3.1 Open hydrant fully and allow a full flow of water to flush main of any foreign matter.

3.3.2 Shut down hydrant and place a 2.5" gate valve on each discharge port, route and then connect approximately 100' of 3" hose to each input connection for the Service Building sprinkler system. (Located outside on the NE corner of the Service Building).

NOTE This connection does not require additional back flow protection since valve #5199N provides this function.

3.3.3 Once all connections have been completed, leave #8 hydrant secured. This hydrant will only be utilized in the event of a failure at one of the other locations.

NOTE Wall hydrant valve #5157 will also be left as is. This will allow further supply if needed at a later date by drafting from the discharge canal with a fire department pumper and connecting 2 additional hoses from that operation to this location.

3.4 At domestic hydrant #9 or #10, remove both 2.5" discharge caps. Tighten large discharge cap.

3.4.1 Open hydrant fully and allow a full flow of water to flush main of any foreign matter.

3.4.2 Shut down hydrant and place a 2.5" gate valve on each discharge port, then connect approximately 200' for hydrant #9 and approximately 350' for hydrant

  1. 10 of 3" fire hose to each gate valve.

SC-3.16.4.1: 5 Rev. 9 3.4.3 Route hose lengths to valve #51 56 located outside the Oil Storage Building.

Place back flow protectors on each input point and connect hoses. Be sure flow of water is from yard hydrant to wall hydrant.

NOTE Where fire hose crosses the plant driveway place hose in a hose bridge to protect from damage.

3.4.4 Open hydrant #9 or #10 slowly and completely.

3.4.5 Open hydrant gate valves slowly and completely.

3.4.6 Inspect fire hose and couplings for any signs of leakage.

3.4.7 Open wall hydrant valve #5156 slowly and completely.

3.5 At hydrant #11 or #13 remove, 2.5" discharge caps. Tighten large discharge cap.

3.5.1 Open hydrant fully and allow a full flow of water to flush the main of any foreign matter.

3.5.2 Shut down hydrant and place a 2.5" gate valve on each discharge port, then connect approximately 250' for hydrant #11 and approximately 200' for hydrant #13 of 3" fire hose to each gate valve.

3.5.3 Route hose to wall hydrant valve #5155 located outside the Auxiliary building east side. Place back flow protectors on each input point and connect hose.

Be sure flow is from yard hydrant to wall hydrant.

NOTE Where fire hose crosses plant driveway place hose in hose bridge to protect from damage.

3.5.4 Open hydrant #11 or #13 slowly and completely.

3.5.5 Open hydrant gate valves slowly and completely.

3.5.6 Once pressure has equalized, inspect all hose and couplings for signs of leakage.

SC-3.16.4.1: 6 Rev. 9 3.5.7 Open wall hydrant valve #5155 slowly and completely.

NOTE Should this procedure be utilized during winter months, each fire hose and opened hydrant will require heat tracing and or insulation to prevent freezing. Where this is not practical, a positive water flow must be maintained on each fire hose.

NOTE Should manual fire fighting require assistance from local fire departments, DO NOT ALLOW ANY ADDITIONAL CONNECTIONS ON THE DOMESTIC YARD HYDRANT SYSTEM WITHOUT APPROVAL BY THE FIRE PROTECTION ENGINEER AS THESE CONNECTIONS COULD REDUCE AVAILABLE WATER SUPPLIES TO THE PLANT.

NOTE Additional water is available by drafting with a fire department pumper from the discharge canal.

3.5.8 Independent verification by a knowledgeable individual, normally an AUX Operator (Active or inactive) or the Fire Protection Engineer to ensure that the cross tie is established in accordance with this procedure.

3.6 Cross tie disconnection.

3.6.1 Shut down wall hydrant valve #5158.

3.6.2 Shut down hydrant #7 and relieve hose pressure by loosening up the couplings at the hydrant.

3.6.3 Once the hose is depressurized, remove hose from hydrant and wall hydrant valve #51 58.

3.6.4 Disconnect each coupling and drain, clean and roll up hose and return to storage.

3.6.5 Place caps back on hydrant and wall hydrant #5158.

NOTE Loosen steamer cap on hydrant so it is hand tight.

3.6.6 Disconnect hose at the fire dept. connection for the Service Building sprinkler system and at hydrant #8.

3.6.7 Disconnect each coupling and drain, clean, roll up and return hose to storage.

3.6.8 Place caps back on hydrant and fire dept. connection.

NOTE Loosen steamer cap on hydrant so it is hand tight.

SC-3.16.4.1: 7 Rev. 9 3.6.9 Shut down wall hydrant valve #5156.

3.6.10 Shut down hydrant supplying water to wall hydrant and relieve pressure by loosening up the couplings at the hydrant.

3.6.11 Once the hose is depressurized, remove hose from hydrant and wall Valve

  1. 5156.

3.6.12 Disconnect each coupling and drain, clean and roll up hose and return to storage.

3.6.13 Place caps back on hydrant and wall hydrant valve #5156.

NOTE Loosen steamer cap on hydrant so it is hand tight.

3.6.14 Shut down wall hydrant #5155.

3.6.15 Shut down hydrant supplying water to valve #5155 and relieve pressure by loosening up the couplings at the hydrant.

3.6.16 Once the hose is depressurized, remove hose from hydrant and wall valve

  1. 5155.

3.6.17 Disconnect each coupling and drain, clean and roll up hose and return to storage.

3.6.18 Place caps back on hydrant and wall hydrant valve #5155.

NOTE Loosen steamer cap on hydrant so it is hand tight.

CROSS TIE INSTALLED BY:

DATE: TIME:

INDEPENDENT VERIFICATION BY:

DATE: TIME:

CROSS TIE REMOVED BY:

DATE: TIME:

FIRE PROTECTION ENGINEER REVIEW:

SC-3.16.4.1: 8 Rev. 9 ATTACHMENT

ATTACHMENT 3 June 18, 2001 Email From NRC To RGE,

Subject:

Loss of SW SDP

Mail Envelope Properties (3B2E0082.8A6: 10: 35430)

Subject:

Re: Loss of SW SDP Creation Date: 6/18/01 9:22AM From: Wayne Schmidt Created By: WLS@nrc.gov Recipients rge.com ThomasHarding (ThomasHarding@rge.com)

Post Office Route rge.com Files Size Date & Time RiskQuestions.wpd 6036 06/18/01 09:18AM MESSAGE 1232 06/18/01 09:22AM Options Expiration Date: None Priority: Standard Reply Requested: No Return Notification: None Concealed

Subject:

No Security: Standard

From: Wayne Schmidt To: ThomasHarding@rge.com Date: 6/18/01 9:22AM

Subject:

Re: Loss of SW SDP Hi Tom - hope you had a good weekend.

Thanks for the last info.

We would like to gather the necessary furhter information this week, so that we can have a call with you, if necessary on Thursday or Friday. Please see the attached questions ( some of the answers overlap, but it was the easist way to make sure the bases were covered)..

I'll be out on Tuesday but in the rest of the week.

Thanks fcor your help.

SDP Questions Ginna SSDI

1. Does the Ginna PRA assume the need for the crosstie of the cooling water from the fire main for total loss of service water scenarios? If so, was the assumption of the frequency of success the same as assumed in AFHDALTTD? If so, this does not appear appropriate since the operator must recognize (proceduralized) the loss of fire water and take actions to align the city water to the fire headers (proceduralized) and also recognize (not proceduralized) the need to connect the temporary supply hose (proceduralized).
2. How would you estimate the Diagnosis HEP for the LOSW event, (given no procedure guiding the operator recognition) verse time for:
1. The alignment of City/Fire water to the TDAFW pump of the need to complete Att 5.2?
2. The alignment of City Water to SAFW?
3. Was the Total mean HEP for the City water to fire water ever calculated? Has it been calculated now? If so what is it? (Please include the calculation).
4. Relative to crediting feed and bleed for a LOSW - What does the current PRA assume?

We think that the SDP assumes no feed and bleed because the recirc capability would not be available. Does the PRA assume anything relative to the time dependance until the RWST reaches the point for swapover? Are there procedures in place for establishing a source of cooling water to the RHR Hxs, without SW?

5. What is the current PRA core damage prob for LOSW? What would the LOSW core damage probability be given: (for each please include the sequences of interest and the assumed failure probabilities. If feed and bleed is credited please explain how.
1. Inability to align Firewater to the TDAFW pump (given nominal failure probability for aligning city water to SAFW).
2. Inability to align Firewater to the TDAFW pump and inability to align city water to SAFW.

ATTACHMENT 4 June 22, 2001 Email From RGE To NRC,

Subject:

NRC Questions

Mail Envelope Properties (3B338D35.177 : 16: 16759)

Subject:

NRC Questions Creation Date: 6/22/01 2:07PM From: <ThomasHarding@rge.com>

Created By: ThomasHarding@rge.com Recipients nrc.gov kplpo.KPDO FJA (Frank Arner)

JMT1 (James Trapp)

WLS (Wayne Schmidt)

Post Office Route kplpo.KPDO nrc.gov Files Size Date & Time MESSAGE 384 06/22/01 02:07PM RiskQuestions.wpd 22509 LOSW2.xls 770560 LOSWI .xls 1518080 Heade-" 990 Options Expiration Date: None Priority: Standard Reply Requested: No Return Notification: None Concealed

Subject:

No Security: Standard

From: <ThomasHarding@rge.com>

To: "Wayne Schmidt" <WLS@nrc.gov>, <JMT1@nrc.gov>, <FJA@nrc.gov>

Date: 6/22/01 2:24PM

Subject:

NRC Questions Attached are our responses to the previous questions.

- - Forwarded by Thomas Harding/NOG/RG&E on 06/22/2001 02:03 PM --------------

Mark Flaherty 06/22/2001 01:53 PM To: Thomas Harding/NOG/RG&E@RG&E cc:

Subject:

NRC Questions Here they are:

(See attached file: RiskQuestions.wpd)(See attached file: LOSW2.xls)(See attached file: LOSWI.xls)

SDP Questions Ginna SSDI In order to ensure that everyone is talking from the same page, here is a summary of the expected loss of service water (LOSW) scenario that will be used as a reference point in responding to the NRC questions.

A. Given a LOSW, the plant would trip either automatically or manually within a few minutes due to loss of BOP related equipment, CCW to the RCPs, etc. The following equipment (as a minimum) will be assumed failed due to the loss of SW:

  • IACompressors A, B, C. However, the service air compressor (normally cross tied to IA)and the diesel air compressor are available.
  • MDAFW Pumps A and B. However, the TDAFW pump will auto start on low SG level (shrink due to reactor trip) and the SAFW pumps will be available.
  • CCW high temperature alarms will result in tripping the CCW pumps. This will fail cooling to the RCPs (which will also be tripped) and the RHR heat exchangers (failing sump recirculation and RHR cooldown).
  • MFW pumps B. Once the plant has tripped, the operators enter procedure E-0. It would be expected that SI conditions would not exist (nor a manual SI required) and operators would exit E-0 after step 4 and enter procedure ES-0.1.

C. Upon exiting E-0, the STA would consult the Critical Safety Function Status Trees (CSFSTs) per EOP usage guides (procedure A-503.1) and the note prior to the first step in ES-0.1. Included within the CSFSTs is verification that there is 200 gpm total AFW flow and 5% level in at least one SG. The STA performs this verification approximately once every 10-20 minutes (step 3.2.10.3 of procedure A-503.1). At this point, there is also a shift briefing to discuss the plant status. It would be expected that the loss of SW would be discussed, but we will assume that this is not discussed for the purpose of this review.

D. Procedure ES-0.1 provides instructions to the operators to stabilize the plant and bring it to hot shutdown conditions. There is a step to verify the number of operating SW pumps

(#5) and a continuous action step (#9) to verify SG level > 5%. The last step of the procedure requires the operators to consult plant staff to determine if cooldown is required and to go to procedure ES-0.2 for natural circulation cooldown (since there are no RCPs). It can be assumed that between the plant staff and licensed operators, that a decision would be made to limit the plant cooldown with no SW present since CCW and RHR are not available. However, it will be assumed that the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> run time with no SW lube oil cooling to the TDAFW pump will not be identified since this is only found in procedure ECA-0.0 (SBO).

E. Procedure ES-0.2 instructs the operators to cooldown and depressurize the RCS using natural circulation. As mentioned above in D, it can be assumed that the plant cooldown would be limited with no SW available. However, it will now be assumed that the TDAFW pump fails after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of operation with no SW cooling for lube oil. Since AFW and maintaining SG level is a basis for providing natural circulation, it would be expected that operators would be monitoring it closely. The STA would also be monitoring these as part of the CSFSTs once every 10-20 minutes. Between these and the expected control board alarms, operators would transition to FR-H.1 upon loss of the TDAFW pump.

F. Procedure FR-H.1 instructs the operators to restore feedwater flow to the SGs first by preferred AFW, then by MFW, then by SAFW. Preferred AFW and MFW will be

assumed unavailable such that only SAFW can be used. EOP Attachment 5.1 instructs the operators to align SAFW taking suction from SW. Procedure ER-AFW.1 provides instructions on how to use alternate suction sources (e.g., city and fire water); however, there is no direct links to ER-AFW.1 from FR-H.1 and Attachment 5.1 other than CST level < 5 feet. Regardless, the operators know that SW is unavailable and have been trained on the use for ER-AFW.1 for similar type circumstances. That is, ER-AFW.1 is considered to be an Abnormal Operating Procedure (AOP) that is referenced by the EOP series of procedures. Operators are trained and expected to utilize AOP type of procedures as needed in support of EOP implementation. Also, the minimum CST level specified in LCO 3.7.6 is based on providing sufficient inventory for the TDAFW pump for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> post trip in accordance with NUREG-0737, item II.E.1.1. As such, the operators would be expected to be procedurally directed into ER-AFW.1 from low CST level at about the same time that the TDAFW pump would fail due to insufficient lube oil cooling.

G. If AFW, MFW, and SAFW cannot be implemented by FR-H.1, then the operators are instructed to use the condensate system or implement feed and bleed. The condensate system has no dependancies on SW, but does require depressurizing the SGs which could be accomplished using ARVs especially given 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of successful TDAFW operation. Feed and bleed occurs until necessary subcooling margin is obtained such that the SI pumps can be stopped and the PORVs closed. At this time, the plant would go to normal RHR shutdown cooling (requires SW), sump recirculation (requires SW), or stabilize on AFW that has been restored. Assuming a SI flowrate of 500 gpm (each pump is designed for 350 gpm and given the initial lower decay heat levels) and 300,000 gallons of RWST inventory, the need to be on RHR or AFW would not occur before 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />. It can be expected that either SW, the TDAFW pump, or SAFW would be recovered within this time frame. However, the PSA model assumes that recirculation capability is required (i.e., there is no credit for this recovery).

1. Does the Ginna PRA assume the need for the crosstie of the cooling water from the fire main for total loss of service water scenarios? If so, was the assumption of the frequency of success the same as assumed in AFHDALTTD? If so, this does not appear appropriate since the operator must recognize (proceduralized) the loss of fire water and take actions to align the city water to the fire headers (proceduralized) and also recognize (not proceduralized) the need to connect the temporary supply hose (proceduralized).

As indicated in PSA Final Report, Appendix F, Table F-4, event AFHFDALTTD is only credited for SBO scenarios (i.e., scenarios where procedure ECA-0.0 is entered). All other scenarios use a value of 1.0 for using fire water to support the TDAFW pump.

2. How would you estimate the Diagnosis HEP for the LOSW event, (given no procedure guiding the operator recognition) verse time for:
a. The alignment of City/Fire water to the TDAFW pump of the need to complete Att-5.2?
b. The alignment of City Water to SAFW?

The diagnosis for alignment of fire water to the TDAFW pump (AFHFDALTTD) and city water to SAFW (AXHFDCITYW) was based on the following:

a. AFHFDALTTD - Cues to perform this action would only be available upon entering ECA-0.0, Step 8.d. All other scenarios do not credit this action (i.e.,

failure probability of 1.0).

b. AXHFDCITYW - Cues to perform this action would be from one of the following:

(1) low CST level - found on foldout page of all EOPs, (2) Step 13.a RNO of Procedure FR-C.1 for inadequate core cooling if SG level cannot be maintained >

5%, (3) Step 7 of Procedure FR-H.1 for inadequate heat sink if SAFW cannot be aligned to SW. Note that for the last item, there is no direct procedural guidance.

However, as described in item F of the event summary, operators are expected to utilize AOPs like ER-AFW. I in a situation like this. The calculation of this value was previously provided to the NRC and assumes that the operator had 20 minutes of diagnosis available. With 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of successful TDAFW operation, this diagnosis time would be much longer.

3. Was the Total mean HEP for the City water to fire water ever calculated? Has it been calculated now? If so what is it? (Please include the calculation).

No HEP for this event has ever been calculated, nor is there any intention of generating one at this time. Instructions to perform this step are not contained within the EOP and AOP series of procedures (i.e., they are in other plant testing procedures). However, this activity is performed during testing and maintenance of the fire water systems and is called out in the TRM for when both fire pumps are inoperable (i.e., establish a backup fire water system). That is, operators are aware of this capability.

4. Relative to crediting feed and bleed for a LOSW - What does the current PRA assume? We think that the SDP assumes no feed and bleed because the recirc capability would not be available. Does the PRA assume anything relative to the time dependance until the RWST reaches the point for swapover? Are there procedures in place for establishing a source of cooling water to the RHR Hxs, without SW?

The PSA utilizes a single transient event tree which contains, among other transients, the LOSW event (see PSA Final Report Figure 5-1). For the feed portion of feed and bleed, top event UH1 on the figure (High Pressure Injection) contains the logic for gate SR500, FAILURE TO DELIVER FLOW FROM 1 OF 3 SI PUMPS TO THE RCS DURING RECIRC. Since no recovery of SW is credited (as described in the event summary, item G), feed and bleed is not success for a LOSW event. However, since it would take over 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> to deplete the RWST, it could be postulated that the SW or AFW system would be recovered, or even the RWST refilled. There is no procedure which establishes an alternate source of cooling to the RHR HXs, primarily due to the number of AFW pumps.

5. What is the current PRA core damage prob for LOSW? What would the LOSW core damage probability be given: (for each please include the sequences of interest and the assumed failure probabilities. If feed and bleed is credited please explain how.)
a. Inability to align Firewater to the TDAFW pump (given nominal failure probability for aligning city water to SAFW).
b. Inability to align Firewater to the TDAFW pump and inability to align city water to SAFW.

Three LOSW scenarios were solved as described below. In no instance is credit for feed and bleed taken.

LOSW as currently addressedwithin the PSA model - The attached cutset file (LOSW1 .XLS) shows a of CDF 3.035E-06 with risk dominated by transients with no AFW available. Note that event AFHFDALTTD is only found in combination with a SBO event. Also, AXHFDCITYW is not found in the cutsets. This is due to the fact that there is already a human error event of failing to start SAFW per EOP steps (AXHFDSAFWX) within the models. For LOSW, this event also includes failure to align city water since no SW is available at the outset.

Consequently, event AXHFDSAFWX was increased by the necessary factor to result in a failure probability of 1.OE-02 similar to AFHFDALTTD.

LOSW with no credit for aligning Firewaterto TDAFW- this is the same as the first sequence since event AFHFDALTTD is only credited for SBO cutsets.

LOSW with no credit for aligning Firewaterto TDAFW nor city water to SAFW- If no credit is taken for TDAFW and the SAFW systems, then the CDF is equivalent to the LOSW frequency, or 2.OOE-04/yr (LOSW2.XLS). However, this scenario is not considered credible due to the reasons described above for the operators treatment of ER-AFW.1 as a AOP which is entered as necessary in the EOPs.

Also, if operators failed to align city water to SAFW in FR-H.1, they would go to feed and bleed. Once this failed due to lack of RWST inventory and ability to go onto RHR, the core would heat up and the operators would enter FR-C.1. This procedure has specific guidance to enter ER-AFW.1 in step 13.a RNO for when SG level is < 5% and 200 gpm of AFW cannot be established. Finally, the use of the condesate system has not been considered.

Cutsets with Descriptions Report

@POWER1 = 3.03E-06 D:ICAFTA- 06/22/2001 13:45

  1. Inputs Description Rate Exposure Event PreoProbability 1 TI0000SW Total Loss of Service Water 1 1.00E+O0 1.06E-06 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG -TRANSIENT EVENT 1 1_00E+00 2 TI00OOSW Total Loss of Service Water 1 1.00E+00 8.76E-07 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)

Sl1E-03 S.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress duoing loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.001-04 1.OOE-04 TRANSX 3 TIOOQSW AAAATRANSI TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Resuts in SI Conditions (Seat LOCA) 1 1.00E+0O I 1.00E+00 1.59E-07 1 1.000E00 LPIQM. YL S CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 4 TI0000SW Total Loss of Service Water 1 I.00E+00 1.32E-07 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR + 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.000E00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 I.00-O04 5 T10000SW Total Loss of Service Water 1 1.00E+00 1.06E-07 AXXVN09728 3 way valve 9728 fails to operate 1.00E-03 1 1.000-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+0O 6 TI00OOSW Total Loss of Service Water 1 1.000E00 8.76E-08 AXXVN09728 3 way valve 9728 fails to operate 1-00E-03 1 1.00E-03 NOSEO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1-0OE-04 1.00E-04 TRANSX TAG -TRANSIENT EVENT 1 1.00E+00 7 TI000OSW Total Loss of Service Water 1 1.00E+00 0.04E-08 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 8 TI0000SW Total Loss of Service Water 1 1.00E+00 4.59E-08 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.290E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 9 Ti0000SW Total Loss of Service Water 1 1.00E+00 3.47E-08 ACAA50_5OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A) 0.83 8.25E.01 ACAZDLOSPI Failure to Restore Offsite Power Within I Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trp 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure ofAC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DG1ANOTRUN FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGt BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 POF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWrODG TAG - SW Lost to DG (cooling) 1 1.00E+00 10 Ti0000SW Total Loss of Service Water 1 1_00E+00 2.87E-08 ACAA5050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.20E-01 ACAZDLOSPI Failure to Restore Offsge PowerWithin I Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Tdp 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 11 T10000SW Total Loss of Service Water I 1.00E+00 2.81E-08 AXTMSAFSGA SAFW TRAIN C TO S/G A O.OS. DUE TO T/M 0.02 1.67E-02 AXTMSAFSGB SAFW TRAIN D TO S/G B O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 12 TIOOOOSW Total Loss of Service Water I 1.00E+00 2.50E-00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E000 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO00515N Motor-Operated Valve 515 ts Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.00 0.00E.02 RCRZT0431C PORV PCV-431C Falls To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.000+00 13 TIoOOOSW Total Loss of Service Water 1 1.00E+00 2.56E-08 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.87E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (510/516) To Terminate LOCA W/n 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03

SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 14 TI000SSW Total Loss of Service Water 1 1.00E+00 2.17E-08 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TiM 0.02 1.67E-02 AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.0DE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76B-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT I 1.0OE+OO 15 TISOOOSW Total Loss of Service Water 1 1_00E+00 2.12E-08 NOSBO TAG - NO STATION BLACKOUT I 1.0DE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.87E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/n 3 Min 0.05 B.SOE-02 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 1 5.O0E-03 SLO TAG - SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1,00E+00 16 TI0000SW Total Loss of Service Water 1 I.002+00 2.12E-08 NOSBO TAG - NO STATION BLACKOUT 1 1.00E600 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/ln 3 Min 0.05 5.0012-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.0BE-03 I 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.OGE+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1G.00E+O 17 TI000SW Total Loss of Seara/e Water I 1.OGE+00 1.16E.O8 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 I 8.85E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+O0 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Firi Events For Stress) 5.19E-S3 5.19E-03 FSAZCORRO3 Condction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to I 1.93E-00 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 18 T10000SW Total Loss of SeOvsoe Water 1 1.OOE+00 9.2gE-0g AXCCSSAFWA Common cause falure of SAFW Pumps IC and 1D to start 8.79E-O5 8.79E-O5 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 19 TI0000SW Total Loss of Service Water I 1.00E+O0 9.05E-09 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00ES00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.OOE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 20 TI0000SW Total Loss of Searvce Water 1 1.00E+00 8.84E-09 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.OOE÷00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI00OOSW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loso of SWlo 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TRANSX TAG - TRANSIENT EVENT I 1.00E+O0 21 TI000OSW Total Loss of Service Water 1 1.00E+00 8.84E-09 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI000OSW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRS3 Correct/on Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-C4 1.14E-04 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 22 TIOOSW Total Loss of Service Water 1 1.00E+00 7.96E-09 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.850-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI000OSW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correct/on Factor for Operators Failing to align SAFW due to increased stress during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E600 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 23 TI00OGSW Total Loss of Service Water 1 1.00E+00 7.70E609 AXCCDMOVNB Common cause failure of MOVs 9701A and 9701B to throttle flor 7.28E-05 7.28E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 088 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 24 TI0000SW Total Loss of Service Water 1 1.00E+00 7.70E-09 AXCCSSAFWA Common cause failure of SAFW Pumps IC and 1D to start 8.70E-05 8.79E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0a88 8-76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.0GE-G4 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 25 TIOOOOSW Total Loss of Service Water 1 1. 0E÷00 7.27E-09 AXHFLSAFWA Failure to restore SAFW Pump Train 1C to service pest test/mault 3.00E-03 3.00EO03 AXMMSAFWPD Failure of SAFW Pump 1 D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 26 TIO00OSW Total Loss of Service Water 1 1.00E+00 7.25E-09 AXHFLSAFWB Failure to restore SAFW Pump Train 1D to service post test/moist 3.00E-03 3.00E-O3 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 NOSBO TAG . NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.0XE+00 27 TIOGOOSW Total Loss of Searice Water 1 1.00E+00 6.38E-09 AXCCDMOVNB Common cause failure of MOVs 9701A and 9701B to throttle flow 7.28E-05 7.28E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG -TRANSIENT EVENT 1 1.00E+00

28 TI0000SW Total Loss of Service Water 1 1.00E+00 6.0E-09 ACAA1000X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZDLOSP1 Failure to Restore Offste Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG- DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.0iE+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I I.0OE+00 29 TIOOSOSW Total Loss of Serioe Water 1 1.00E+00 6.03E-09 AXHFLSAFWA Failure to restore SAFW Pump Train 1C to service post test/maint 3.OBE-03 3.00E-03 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSED TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 30 TI0000SW Total Loss of Service Water 1 1.00E+00 6.01E-09 AXHFLSAFWB Failure to restore SAFW Pump Train 1D to service post test/maint 3.00E-03 3.001-03 AXMMSAFWPC Failure of SAPW Pump lC train 0.02 2.28E-02 NOSBO TAG - NO STATION BLACKOUT I 1.00Eu00 PCF PLANT CAPACITY FACTOR 048 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 31 TI0000SW Total Loss of Service Water 1 1.00E+00 5.685E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPALP NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER 5.34E-05 5.34E-05 NOSBE TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.0OE+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 32 T10000SW Total Loss of Service Water 1 1.00E+00 5.65E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPBLP SEAL LEAKOFF PATH FROM ROP B OBSTRUCTED 5.34E-05 5.34E-05 NOSBE TAG - NO STATION BLACKOUT 1 100E+00 PCF PLANT CAPACITY FACTOR 0-88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR + 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 33 TI0000SW Total Loss of Service Water 1 1.00E+00 5.30E-09 AXHFLSAFWB Failure to restore SAFW Pump Train 1 D to service post test/maimt 3.00E-03 3.00E-03 AXTMSAFSGA SAFW TRAIN C TO SIG A O.O.S. DUE TO TIM 0.02 1.67E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.0OE÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 34 TIO0OOSW Total Loss of Service Water 1 1.00E+00 5. 16E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPAFP NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL 4.88E-05 4.88E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR v I HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 35 TI0000SW Total Loss of Service Water 1 1.00E+00 5.16E609 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPBFP NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER 4.88E-05 4.88E-05 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR 5 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 36 TIOiOOSW Total Loss of Service Water 1 1.00E+00 8.02E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In St Conditions (Seal LOCA) 1 1.00E+00 CVPPJCVCOM Common CVCS Piping Ruplure 1.98E-06 24 4.75E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR u 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 37 TI000OSW Total Loss of Service Water 1 1.00E+00 5.02E-09 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZDLOSPI Failure to Restore Offshe Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1-006+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully I 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 38 TIS00OSW Total Loss of Service Water 1 1.00E÷00 4.69E-09 AXHFLSAFWA Failure to restore SAPW Pump Train 1 C to service post test/maimt 3.00E-03 3.00E-03 AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TO TIM 0.01 1.48E-02 NOSBE TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 06.8 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 39 TI0000SW Total Loss of Service Water 1 1.00E+00 4.68E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPALP NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER 5.34E-05 5.34E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR 5 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 40 TiOOitOSW Total Loss of Service Water I 1.00E+00 4.68E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)

I 1.00E+00 CVMMRCPBLP SEAL LEAKOFF PATH FROM RCP B OBSTRUCTED 5.34E-05 6.34E-05 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAGO- TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1 00E-04 1.00E-G4 41 TI0000SW Total Loss of Service Water I 1.00E+00 4.46E-09 FSTMFCITYW City Water Supply to Yard Fire Loop Inoperable 4.22E-05 4.22E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8076E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E*00 42 T10000SW Total Loss of Service Water 1 1.00E+00 4.39E-09 AXHFLSAFWB Failure to restore SAFW Pump Train 1D to service post test/maint 3.OOE-03 3.00E-03 AXTMSAFSGA SAFW TRAIN C TO S/G A O.OS. DUE TO T/M 0.02 1.67E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.70E-01 S*WXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1 .00E04 TRANSX TAG - TRANSIENT EVENT 1 1.00Eu00 43 T10000SW Total Loss of Service Water 1 1.00E+00 4.27E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.001+00 CVMMRCPAFP NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL 4.88E-05 4.88E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 4TI0000SW Total Loss of Service Water I 1.00E+00 4.27E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in 31 Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPBFP NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER 4.88E-05 4.88E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0088 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR 5 1 HOUR 1 t.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS I 1.OOE+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 45 "10000SW Total Loss of Service Water 1 1.00E+00 4.16E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVPPJCVCOM Common CVCS Piping Rupture 1.98E-06 24 4.75E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.,OE+00

  • WCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 46 TIOOOOSW Total Loss of Service Water 1 1.00E+00 3.89E-09 AXHFLSAFWA Failure to restore SAFW Pump Train 1C to service post test/moaint 3.00E-03 3.0OE-03 AXTMSAFSGB SAFWTRAIN D TO S/G B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.OOE-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1 OOE+00 47 TI0000SW Total Loss of Service Water 1 1.05E+00 3.70E-09 FSTMFCITYW City Water Supply to Yard Fire Loop snoperable 4.22E-05 4.22E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E-00 PCF PLANT CAPACITY FACTOR 0.88 &.78E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 48 T10000SW Total Loss of Service Water 1 1.00E+00 2.56E-09 AAAATRANSI TAG -Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.O0E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFD0ORCP Operators Fail to Trip RCPs After Loss of Support Systems 0.02 1.61E-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.BOE+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 49 TI0000SW Total Loss of Service Water 1 1.00E+00 2.52E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50_5OA FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.0 5.00E-01 ACLOPRT751 Loss of Offsie Circuit 751 Following Reactor Trip 2-12E-03 2-12E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG18NOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR 5 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.002+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I t.00E÷00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - BW Lost to DG (cooling) 1 1.00E+00 50 T10000SW Total Loss of Service Water 1 1.00E+00 2.50E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 ACAAS050A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKCT767 TO BUS 12A) 0083 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ANOff-Site Power Following Reactor Trip 2.10E-03 2.1OE-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E÷00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.7BE-01 RCAZO01RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00Eu00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 51 T7100OSW Total Loss of Service Water 1 1.00Eu00 2.12E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Resuots in SI Conditions (Seal LOCA) 1 1.006+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSB03 TAG - NO STATION BLACKOUT 1 1.OOE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFDOORCP Operators Fail to Trip RCPS After Loss of Support Systema 0.02 1.81E-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.002E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00En00 SWCa3SUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 52 T10000SW Total Loss of Service Water 1 1.00E+00 2.11E-09 ACAAS_50A FLAG - OFFSITE POWER MODE 50050 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Less of Offsite Circuit 767 Foilowing Reactor Trip 2.12E-03 2.12E-03

ACTRAINA TAG - Failure of AC Train A 1 1.OOE+00 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1 .OE÷00 TRANSX TAG - TRANSIENT EVENT 1 1.09E+00 53 TIOOOOSW Total Loss of Service Water 1 1.00)E00 2.11E-09 ACAA50.50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSt2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0,5 5.00E-01 ACLOPRT751 Loss of Offste Circuit 751 Following ReactorTop 2.12E-03 2.122-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.09E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 54 TIOOOOSW Total Loss of Service Water 1 1.00E+00 2.11E-09 AXCCFSAFWA Common cause failure of SAFW Pumps 1C and 1D to run 1.99E-05 1.99E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.7SE-O1 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.OOE÷00 55 TI0000SW Total Loss of Service Water 1 1.0)E+00 2.09E-09 ACAASO_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 797 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.02E-01 ACLOPRTALL Loss of ANOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.009+00 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.50E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+50 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 56 TIOOOOSW Total Loss of Service Water 1 1.00E+00 2.09E-09 ACAASO_50A FLAG- OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO S CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Top 2.10E-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E÷00 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 57 TI0000SW Total Loss of Service Water 1 1.00E+00 2.09E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00-E01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B 1 1.50E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+0 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1509E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.0OE-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 58 TI0000SW Total Loss of Service Water 1 1.00E+00 2.07E-09 A.AATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditioos (Seal LOCA) I 1.00E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 129, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.009-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DGoBNOTRUN FLAG - DG o IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.009+00 SSLO TAG - SMALLSMALL LOCA SEQUENCE I 1.00E+50 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E.04 1.09E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+50 59 TI0000SW Total Loss of Service Water I 1.00E+00 1.82E-09 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.05E-03 ACTRAINA TAG - Failure of AC Train A 1 1.50E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Comncted for TI000OSW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.50E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.22E-03 3.28E-03 SWTMPUMP1 D SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 60 TIOOOOSW Total Loss of Service Water I 1.00E+00 1.75E-09 ACAA50.50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.50E-01 ACLOPRT767 Loss of Offsoe Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.09E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to Do (cooling) 1 1.00E+50 TRANSX TAG - TRANSIENT EVENT I 1.09E+50 61 TI0000SW Total Loss of Service Water 1 1.50E+00 1.75E-09 ACAAS050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.50E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following ReactorTop 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B 1 11.00E+0 AXMMSAFWPC Failure of SAFW Pump IC twin 0.02 2.29E-02 DG1 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.50E+00

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWC)XSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E-00 62 Ti0000SW Total Loss of Service Water 1 1.00E-00 1.75E-09 AXCCFSAFWA Common cause failure of SAFW Pumps 1C and 1D to run 1.99E-05 1.99E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT I 1.00E>00 63 T10000SW Total Loss of Service Water I 1.00E+00 1.74E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+n0 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWMOOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1 B SW Pump B in maintenance 0.05 4.55E-02 64 TI00OOSW Total Loss of Service Water 1 1.00E+00 1.73E-09 ACAA50_0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E-00 AXMMSAFWPD Failure of SAFW Pump 10 Train 0.02 2.29E-02 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 65 TI0000SW Total Loss of Service Water 1 1.00E+00 1.73E-09 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00-E01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B 1 1_00E800 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1B AND 17 I 9.97E-01 NOSBO TAG . NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00o-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1_00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 66 T10000SW Total Loss of Service Water 1 1.00E-00 1.44E-09 AAAATRANSI TAG - Transient Initiating Event Whicih Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 CVCCMPFABC COMMON CAUSE FAILURE OF THE CHARGING PUMPS TO RUN 1.36E-05 1.36E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00>E00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Servrce Water Pumps To Run 1.21E-04 1.21E-04 67 T10000SW Total Loss of Service Water 1 1.00E+00 1.36E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.0OE+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.008E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR u 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.0OE+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 68 T10000SW Total Loss of Service Water 1 1.00E+00 1 33E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.001+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 89 T10000SW Total Loss of Service Water 1 1.001+00 1.33E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSB00 TAG - NO STATION BLACKOUT 1 1.001+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0B1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00>E00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 70 T10000SW Total Loss of Service Water 1 1.00E+00 1.20E-09 AAA*TRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.501-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > I HOUR 1 1.00E800 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTvIMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 71 T10000SW Total Loss of Service Water 1 1.00E+00 1.19E-09 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 CVCCMPFABC COMMON CAUSE FAILURE OF THE CHARGING PUMPS TO RUN 1.36E-05 1.36E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG . TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALLSMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 72 TIOOSW Total Loss of Service Water 1 1.00E+0O 1.19E-09 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.18E-03 5.19E-03

FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00EQ00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-0l SWAASWPICR FLAG - Service Water Pump PSWO1 C Is In Operation 0.58 5.79E-01 SWCVC04603 Service Water Pump PSWsIC Discharge Check Valve 4603 Fails To Close On Demand 5.84E-04 1 5.84E-04 SWVTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.O0E+0O 73 T10000SW Total Loss of Service Water I 1.00E+00 1.16E-09 ACE2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.86E-03 ACTRAINA TAG - Failure of AC Train A I 1.O0E+0O AXXVN09728 3 way valve 9728 fails to operate 1.0E-03B 1 l10E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1E SW Pump E In maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 74 I50000SW Total Loss of Service Water I 1.00E+00 1.14E-09 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDO0515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCMVC0051 5 MOV 515 fails to close 2.22E-03 1 2.22E-03 RCRZT0431 C PORV PCV-431 C Fails To Reseat After Steam Relief S.DOE-G3 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1,001E00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 75 TIOOOOSW Total Loss of Service Water 1 1.00E+00 1.14E209 NOSEO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCMVC00515 MOV 515 fails to close 2.22E-03 1 2.22E-03 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.OE-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.SOE+00 78 TIOOOOSW Total Loss of Service Water 1 1.002+00 1.13E-O9 AXMMSGBSAF Failure of SAFW injection line to SIG B 6.39E-04 8.39E-04 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M 0.02 1.67E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E200 77 TIOOOOSW Total Loss of Service Water 1 1.00E+00 9.52E-10 AXHFLSAPWA Failure to restore SAFW Pump Train IC to service post testlmaint 3.0OE-03 3.00E-03 AXHFLSAFWB Failure to restore SAFW Pump Train 1D to service post test/mrint 3.00E-03 3.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E÷00 78 TI000OSW Total Loss of Service Water 1 1.00E+00 9.41E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDD0515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCMVC00515 MOV 515 fails to close 2.22E-03 1 2.22E-03 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00-E03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.OSE÷00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.OoE-04 1.00E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 79 T10000SW Total Loss of Service Water 1 1.0OE+00 9.41E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.SOE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCMVCO0515 MOV 515 fails to close 2.22E-03 I 2.22E-03 RCRZTO0430 PORV PCV-430 Fails To Reseat After Steam Relief 5.0E-03 1 5.O0E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00+O00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I l.OGE+00 80 TI0000SW Total Loss of Service Water 1 1.00E+00 9.34E-10 AXMMSGBSAF Failure of SAFW injection line to S/G B 6.39E-04 6.39E-04 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM 0.02 1.67E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) l.OOE-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 81 TI000OSW Total Loss of Service Water 1 1.00E+00 9.33E-t0 ACE2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 f.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.OE+00 AXHFDSAFWX Operators Fail to Cotrectly Align SAFW (Corredced for T1000OSW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWOEB Is In Operation 0.58 5.79E-01 SWCVC04802 Service Water Pump PSWOlB Discharge Check Valve 4602 Fails To Close On Demand 5.84E-04 1 5.84E-04 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 82 TIOOOOSW Total Loss of Service Water 1 1.00E+00 9.15E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+OO PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDO0515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCCCFPORVC PORVs FAIL TO CLOSE (CCF) 1.79E-04 1.79E-04 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 500E2-02 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 121E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 83 TI000OSW Total Loss of Service Water 1 1.00E*00 9.15E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.87E-01 RCCCFPORVC PORVs FAIL TO CLOSE (CCF) 1.79E-04 1.79E-04 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 SLO TAG - SMALL LOCA SEQUENCE 1 1.002+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 84 T10000SW Total Loss of Service Water 1 1.00E+00 9.05E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00Ea00 AXXVN09728 3 way salve 9728 fails to operate 1.OOE-03 1 1.00E-03 NOSEO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.OOE+00 85 TI0OOSW Total Loss of Service Water 1 1.00E+00 8.86E-10 MLO TAG - MEDIUM LOCA SEQUENCE 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

RCAZDO0515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCCCFPORVC PORVs FAIL TO CLOSE (CCF) 1.79E-04 1.79E-04 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLMTRANS TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES I 1.00E-00 86 T10000SW Total Loss of Service Water 1 1.00Eg00 8.84E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-06 1 8.85E-03 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AXXVN09728 3 way valve 9728 fails to operate 1.00E-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.O0E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TRANSX TAG - TRANSIENT EVENT 1 1.O0E+00 87 T10000SW Total Loss of Service Water 1 1.001+00 8.84E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXXVN09728 3 way valve 9728 fails to operate 1.00E-03 1 i.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00EO+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 88 TI0000SW Total Loss of Service Water 1 1.00E+00 8.78E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACCBD2BTAA 4160 VAC Bus 11A / Bus 12A Tie Breaker 521BTA-A (BUS1 t1A/1) Fails to Close 3.64E-03 1 3.64E-03 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 IAAACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9.50E-01 IAHFDCSA04 OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > I HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1-00E+00 SWCCIPUMPSR Common Cause Failurl Of Service Water Pumps To Run 1.21E-04 1.21E-04 89 TI0000SW Total Loss of Service Water 1 1.00E+00 8.78E-10 AAAATRANSI TAG -Transient Initiating Event Which Eventually Rsults In SI Conditions (Seal LOCA) 1 1.00E+00 ACCBD521 1A 4160 VAC Circuit Breaker 52111A (BUS1 1A10) Fails To Open on Demand 3.64E-03 1 3.64E-03 CVHFDSUCTN Operators Fail to Manually Open Suction Une Upon Loss of IA 0.02 2.40E-02 LA.AACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9.50E-01 IAHFDCSA04 OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.00E-01 NOSSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E-00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 90 T10000SW Total Loss of Service Water 1 1.00E+00 8.34E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.05E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correctin Factor for Operators Failing to align SAFW due to increased stress duoing loss of SW to 1 1.93E+00 NOS8 TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 TRANSX TAG - TRANSIENT EVENT 1 1.001+00 91 TIOO0OSW Total Loss of Service Water I 1.00E+00 8.34E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIO000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stresw during loss of SWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 92 TIOOOOSW Total Loss of Service Water 1 1.00E+00 8.201-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.190E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFWdue to increased stress during loss of SWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.98 8.76E-01 SWAASWP1DR FLAG- Service Water Pump PSWIlD Is In Operation 0.58 5.79E-01 SWCVC04604 Service Water Pump PSW01 D Discharge Check Valve 4604 Fails To Close On Demand 5.84E-04 1 5.84E-04 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT 1 1.00E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 93 TIO000SW Total Loss of Service Water 1 1.00E+00 7.96E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 I 8.85E-03 ACTRAINB TAG - Failura of AC Train B 1 1.00E+00 AXXVN09728 3 way valve 9728 fails to operate 1.00E-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMM0SWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.130-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 94 T10000SW Total Loss of Service Water 1 1.00E+00 7.88E-10 AXHFLSAFWA Failure to restore SAFW Pump Train 1 C to service post test/maint 3.OOE-03 3.00E-03 AXHFLSAFWB Failure to restore SAFW Pump Train 1 D to service post toestmaint 3.00E-03 3.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.000-04 1.00-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 95 T10000SW Total Loss of Service Water 1 1.00E+00 7.84E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM00112B AOV 112B FAILS TO OPEN ON DEMAND 0.18 1.83E-01 CVMMRXMAKE FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER 1.69E-03 1.69E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ00t RCP NO RCP SEAL COOLING FOR 0 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 96 TI0000SW Total Loss of Service Water 1 1.00E+00 7.78E-10 AXMMSGASAF Failure of SAFW injection line to S/G A 4.97E-04 4.97E-04 AXTMSAFSGB SAFW TRAIN D TO SbG B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 97 T10000SW Total Loss of Seroice Water I 1.00E+00 7.67E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD0051 SN Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.87E-01 RCMMO00515 ELECTRICAL FAILURES PREVENT MOVING MOV-515 1.5OE-03 1.50E-03 RCRZT0431C PORV PCV-431 C Fails To Reseat After Steam Relief 5.00E-03 I 5.O0E-03 SLO TAG - SMALL LOCA SEQUENCE I 1.OOE+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 98 T10000SW Total Loss of Service Water 1 1.00E-00 7.67E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.00E800 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCMM000516 ELECTRICAL FAILURES PREVENT MOVING MOV-516 1.50E-03 1.50E-03 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 I 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE I 1.OOE+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 99 TI0000SW Total Loss of Service Water 1 1.00E+00 7.58E-10 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD0051 SN Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCCCFPORVC PORVs FAIL TO CLOSE (CCF) 1-79E-04 1.79E-04 RCHFDPLOCA Operators Fail To Close PORV Block Valfe (5159516) To Termlinate LOCA Won 3 Min 0.05 5.00E-02 SLO TAG - SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.0OE-04 1.00E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 100 TI0000SW Total Loss of Service Water 1 1.00E+00 7.58E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCCCFPORVC PORVs FAIL TO CLOSE (CCF) 1.79E-04 1.79E-04 RCHFDPLOCA Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA WIln 3 Min 0.05 5.00E-02 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.006E00 101 TI000SW Total Loss of Service Water 1 1.006E00 7.34E-10 MLO TAG - MEDIUM LOCA SEQUENCE 1 I.00+E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOS1SN Motor-Operated Vale 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCCCFPORVC PORVs FAIL TO CLOSE (CCF) 1.79E-04 1.79E-04 RCHFDPLOCA Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA WIln 3 Min 0.05 5.00E-02 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TLMTRANS TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES 1 1.00E+00 102 T10000SW Total Loss of Service Water 1 .00OE+00 7.27E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in S1 Conditions (Seal LOCA) 1 1.00E+00 ACCBD2ETAA 4160 VAC Bus 1A/ Bus 12A Tie Breaker 52/1TA-A (BUS11A/11) Fails to Close 3.64E-03 1 3.64E-03 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 IAAACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9.50E-01 IAHFDCSA04 OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ01 RCP NO RCP SEAL COOLING FOR - 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 103 TI0000SW Total Loss of Service Water 1 1.00E+00 7.27E-10 AAAATRANSI TAG - Transient Inltiatiag Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACCBO5211A 4160 VAC Circuit Breaker 52/t1A (BUS1 1A/10) Fails To Open on Demand 3.64E-03 1 3.64E-03 CVHFDSUCTN Operators Fail to Manually Open Sucdon Line Upon Loss of IA 0.02 2.40E-02 IAAACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9.50E-01 IAHFDCSA04 OPERATORS FAILTO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.006E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZS01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 104 TI0000SW Total Loss of Service Water 1 1.00E+00 7.22E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 I 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0-88 8786E-01 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 105 TI0000SW Total Loss of Service Water 1 1.00E+00 7.16E-10 AAAATRANSI TAG - Transient Initiating Event Whtich Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM7T0S/A VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED 0.17 1.67E-01 CVMMRXMAKE FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER 1.69E-03 1.69E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8-76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00OE00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 106 TI0000SW Total Loss of Service Water 1 1.00E+00 7.15E-10 ACAAS_505N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSPI Failure to Restore Offsfe PowerWdhin 1 Hour 0.38 3.81E-01 ACLOPNOSi2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Ant Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00OE+00 ACTRAINB TAG - Failure of AC Train B I 1.0DE+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 OGIANOTRUN FLAG - DG lA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 S8O TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 107 TI0OOSW Total Loss of Service Water 1 1.00E+00 6.71E-10 AXCCPSGINB Common cause failure of check avles 9705A and 9705B to open 6.35E-06 8.35E-06 NOSBO TAG - NO STATION BLACKOUT I 1.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG -TRANSIENT EVENT 1 1.006+00 108 T10000SW Total Loss of Service Water 1 1.00E+00 8.59E-10 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZOLLOSP1 Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss ofJl Off-See Power Following Reactor Trp 2.10E-03 2.101-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00

ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFTMOTDAFW TDAFW Pump Train out-of-service for maintenance 0.02 1.90E-02 DOGIANOTRUN FLAG - DOGIA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGI BNOTRUN FLAG -0G 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8E76E-01 S0O TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.0OE+00 109 T10000SW Total Loss of Service Water 1 1.00E+00 6.50E-10 AAAATRANBI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM00112B AOV 1128 FAILS TO OPEN ON DEMAND 0.18 1.83E-01 CVMMRXMAKE FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER 1.69E-03 1.69E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR + 1 HOUR 1 1.00E.00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUC-n TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 110 T10000SW Total Loss of Service Water 1 1.00E+00 6.45E-10 AXMMSGASAF Failure of SAFW injection line to S/G A 4.97E-04 4.97E-04 AXTMSAFSGB SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+000 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 111 T10000SW Total Loss of Service Water 1 1.00E+00 6.36E810 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDO0515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCMM000515 ELECTRICAL FAILURES PREVENT MOVING MOV-515 1.50E-03 1.50E-03 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 1 S0OE-03 SLO TAG - SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 112 T10000SW Total Loss of Service Water 1 1.00E+00 8.36E-10 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCMM000516 ELECTRICAL FAILURES PREVENT MOVING MOV-516 1.50E-03 1.50E-03 RCRZT0O430 PORV PCV-430 Falls To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+000 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.000E04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 113 T10000SW Total Loss of Service Water I 1.00E+00 8.31E-10 ACAA0_100X FLAG - OFFSITE POWER MODE 0/100 (CKT 701 SUPPLYING BUSES 12A AND 12B) 0.02 1.50E-02 ACAZDLOSP1 Failure to Restore Oflsite Power Within 1 Hour 0.38 3.81 E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 0.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Top 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 AFAXITDAFW` TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG 01 B NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Sermce Water Pumps To Run 1.21E-04 1-21E-04 SWrODG TAG - SW Lost to DG (cooling) 1 1 00E+00 114 T10000SW Total Loss of Service Water 1 1.00E+00 6.11E-10 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZDLOSP1 Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsie Circuit 767 Foliowing Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.000+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.000000 DGiANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 115 T10000SW Total Loss of Service Water I 1.00E+00 6.07E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8-85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 116 T10000SW Total Loss of Service Water 1 100E+00 5.93E-10 AAAATRANSI TAG - Transient Initiating Event Wthich Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Une Upon Loss of IA 0.02 2.40E-02 CVMM7005/A VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED 0.17 1.87E-01 CVMMRXMAKE FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER 1.69E-03 1.69E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.COE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR o 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 117 T10000SW Total Loss of Service Water 1 1.00E+00 5.92E-10 ACAA5050N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 787 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSP1 Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of At Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 Sao TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00-E04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 118 T10000SW Total Loss of Service Water 1 1.00E+00 5.89E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stras during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01

SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWSOIA 1.00E-06 1 8.76E-03 SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWSOI B 1.006-06 1 8.76E-03 SWTSFFSWCI PLUGGING OF TRAVELLING SCREEN FWSOIC 1.00E-06 1 8.76E-03 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 119 T10000SW Total Loss of Service Water 1 1.00E+00 5.89E.10 AXHFDSAFWX Operators Fail to Correctly Align SAPW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.198-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SWlo 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.006+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG . CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWSO1A 1.00E-06 1 8.786-03 SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWS0B 1.00E-06 1 8.76E-03 0WTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS01D 1.00E-06 I 8.76E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 120 T10000SW Total Loss of Service Water 1 1.006E00 5.89E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.1GE-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWS01A 1.00E-06 1 8.76E-03 SWTSFFSWCI PLUGGING OF TRAVELLING SCREEN FWSO1C 1.00E-06 1 8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS01D 1.00E-06 1 8.786E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 121 TI7OOOSW Total Loss of Service Water I 1.00E+00 5.89E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.006E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01 SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWOS1B 1.00E-06 1 8.76E-03 SWTSFFSWCI PLUGGING OF TRAVELLING SCREEN FWS01C 1.00E-06 1 8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWSO1D 1.00E-06 1 8.76E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 122 T10000SW Total Loss of Service Water I 1.00E+00 5.65E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.016E-0* 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress durng loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 123 T10000SW Total Loss of Service Water I 1.00E+00 5.56E-10 AXCCPSGINB Common cause failure of dieck vnales 9705A and 9705B to open 6.35E-06 8.35E-00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

  • WCXXSUCTI TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 124 T10000SW Total Loss of Service Water 1 1.00E+00 5.486E-10 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsite Power Wethin 1 Hour 0.38 3.816-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Top 2.1OE-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFTMOTDAFW TDAFW Pump Train out-of-service for maintenance 0.02 1.90E-02 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG01BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.006-04 1.00E-04 SWTODG TAG - SW Lost to 10 (cooling) 1 1.00E+00 125 T10000SW Total Loss of Service Water 1 1.00E+00 5.23E-10 ACAAOJ100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.50E-02 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3-81E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AtIOff-SOle Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AFAXITDAFW TAG - TOAFW Pump operates successfully 1 1.00oE+0 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.768-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SW-TODG TAG - SW Lost to DG (cooling) 1 1.00E+00 126 T10000SW Total Loss of Service Water 1 1.00E+00 5.06E-10 ACAA1 DOOX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO S? CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Less of OfGsle Circuit 767 Following ReactorTrip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfulty 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1ENOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 ACHFDRCOFF Failure to recover second offsie power circuit after failure of first 0.1 1.00E-01 127 T10000SW Total Loss of Service Water 1 1.00E+00 4.96E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AXHFDSAFWJX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Corection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 TRANSX TAG - TRANSIENT EVENT I 1.00E600 128 T10000SW Total Loss of Service Water 1 1.00E+00 4.92E-10 FSXVK8549 MANUALVALVE 8549 TRANSFERS CLOSED 1.94i-07 24 4.66E-08 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 129 T10000SW Total Loss of Service Water 1 1.006+00 4.75E-10 ACB2FI6S17 Local Faulv on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAIN8 TAG - Failore of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02

___a a a TAG - NO STATION BLACKOUT 1 1.00+500 NOSBO 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPAS 0.04 3.56E-02 SWTMPUMPIC SW Pump C in maintenance 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 4.64E-10 130 TI0000SW Total Loss of Servce Water 1.01E-06 1 8.85E-03 ACB2FIBSI7 Local Fauft on 480 VAC Bus 17 1 1.00E+00 ACTRAINB TAG - Failure of AC Train 8 0.02 2.29E-02 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 1.14E-04 1.14E-04 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 4.641-10 131 T10000SW Total Loss of Service Water 1.01E-06 1 8.85E-03 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1 1.00E+00 ACTRAINA TAG - Failure of AC Train A 0.02 2.29E-02 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 1.14E-04 1.14E-04 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.000+00 4.46E-10 132 T10000SW Total Loss of Service Water 0.83 8.25E-01 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.5 5.00E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO S0 CONDITION FOR LOOP 2.12E-03 2.12E-03 ACLOPRT751 Loss of Offshe Circuit 751 Following Reactor Trip I 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 0.97 9.67E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 5.00E-03 1 5.00E-03 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief I 1.00E+00 SLO TAG - SMALL LOCA SEQUENCE 1.21E-04 1.21E-04 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run I 1.00E+00 SWrODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 4.46E-10 133 T10000SW Total Loss of Service Water 0.83 8.25E-01 ACAA*0_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)

CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPNOSI2 Loss of Offsite Circus 767 Following Reactor Trip 2.12E-03 2.12E-03 ACLOPRT767 1 1.00E+00 ACTRAINA TAG - Failure of AC Train A 1 9.97E-01 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT 1 1.00E+00 NOSBO 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 0.97 9.67E-01 RCAZDO0516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 RCRZT00430 1 1.00E+00 SLO TAG - SMALL LOCA SEQUENCE 1.21E-04 1.21E-04 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 4.42E-10 134 T10000SW Total Loss of Service Water 0.83 8.25E-01 ACAA50-50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)

CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.0OE-01 ACLOPNOSt2 Loss of All Off-SOte Power Following Reactor Trip 2.10E-03 2.10E-03 ACLOPRTALL 1 1.00E+00 ACTRAINA TAG - Failure of AC Train A 1 9.97E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 0.97 9.67E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 5.00E-03 1 5.00E-03 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 1 1.00E+00 SLO TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Sevice Water Pumps To Run 1.21E-04 1.21E-04 SWCCIPUMPSR 1 1.00E+00 SWTODG TAG - SW Lost to DG fcooling)

TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 TLSTRANS 1 1.00E+00 4.42E-10 135 T10000SW Total Loss of Service Water 0.83 8.25E-01 ACAAS_50CA FLAG - OFFSITE POWER MODE 80/50 ALT (CKT 751 TO BUS 12B. CKT 787 TO BUS 12A) 0.5 5.00E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip 2.10-E03 2.10E-03 ACLOPRTALL TAG - Failure of AC Train B 1 1.00E+00 ACTRAINB FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES I1 AND 17 1 9.97E-01 DGIBNOTRUN 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 0.87 9867E-01 RCAZD00515N Motor-Operated Valve 510 Is Not Closed Due to PORV Leakage PORV PCV-431C Fails To Reseat After Steam Relief 5.0OE-03 1 5.00E-03 RCRZT0431C 1 1.00E+00 SLO TAG - SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 1 1.001+00 SWTODG TAG - SW Lost to DG (ceoling)

TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 TLSTRANS 1 1.00E+00 4.40E-10 136 T10000SW Total Loss of Service Water 1 1.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Coeditions (Seal LOCA)

FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 123 AND 12B) 0.14 1.44E-01 ACAA100_OX CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.001-01 ACLOPNOSI2 2.12E-03 2.12E-03 ACLOPRT767 Loss of OffsheCircuit 767 Following Reactor Trip 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVAACHPMPC TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPA FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.971-01 DGIBNOTRUN 1 1.00E+00 NOSSO TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR 0.88 8.76E-01 PCF NO RCP SEAL COOLING FOR + 1 HOUR 1 1.00E+00 RCAZO01RCP TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SEALLOCA TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SSLO 1.21E-04 1.21E-04 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling)

Total Loss of Service Water 1 1.00E+00 4.36E-10 137 T10000SW 1 1.00E+00 AAAATRANSI TAG - Treoslent Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 0.14 1.44E-01 ACAA1000iX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)

CORRECTION FACTOR FOR NO S0 CONDITION FOR LOOP 0.5 5.00E-01 ACLOPNOSI2 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPB 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPA 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 NOSBO TAG - NO STATION BLACKOUT 1 1.001+00 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 1 1.00E+00 RCAZ001RCP NO RCP SEAL COOLING FOR + 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 I 1.00E+00 SSLO TAG - SMALL SMALLLOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWCCIPUMPSR TAG - SW Lost to DG (ceoling) 1 1 00E+00 SWTODG I 1.00E+00 4.17E-10 138 T10000SW Total Loss of Service Water

ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E800 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 AXMMSAFWPO Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 139 TIOCOSOW Total Loss of Service Water 1 1.00E+00 4.10E-10 AAAATRANSI TAG - Transient Initiating Event Which Evenlually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM00110B AOV 1108 FAILS TO OPEN OR TRANSFERS CLOSED 8.83E-04 8.83E-04 CVMM001 12B AOV 112B FAILS TO OPEN ON DEMAND 0.18 1.83E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ00I RCP NO RCP SEAL COOLING FOR u 1 HOUR 1 1.00E800 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 140 TI0008SW Total Loss of Service Water 1 1.00E+00 4.08E-10 FSXVK8549 MANUALVALVE 8549 TRANSFERS CLOSED 1.94E-07 24 4.86E-06 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 141 T10000SW Total Loss of Service Water 1 1.00E+00 4.06E810 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ADOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFMMOTDAFW Failure of TDAFW pump train components 0.01 1.17E-02 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.218E-4 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 142 TIO0OOSW Total Loss of Service Water 1 1.00E+00 4.04E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in 0I Conditions (Seal LOCA) 1 1.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKlT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsie Circuit 767 Following Reactor Trip 2.128-03 2.128-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM001 12B AOV 112B FAILS TO OPEN ON DEMAND 0.18 1.83E-01 DGlANOTRUN FLAG - 00 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 IBAABUSBMX FLAG - InstIrment Bus B on Normal Supply 1 9.99E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00+>00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to 0G (cooling) 1 1.00E+00 143 TIOCOSW Total Loss of Service Water 1 1.00E+00 4.01E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKOT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction bne Upon Loss of IA 0.02 2-40E-02 CVMM001 12B AOV 112B FAILS TO OPEN ON DEMAND 0.18 1.83E-01 DGIANOTRUN FLAG - D0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.978-01 IBAABUSBMX FLAG - Instrument Bus B on Normal Supply 1 9.99E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR u 1 HOUR 1 1.00E>00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E800 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooeing) 1 1.001+00 144 TIOOOOSW Total Loss of Service Water I 1.00E+00 3.80E-10 AXMMSAFWPD Failure of SAFW Pump 1 D Train 0.02 2.29E-02 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM 0.02 1.67E-02 AXXVK9702D Manual valve 9702D transfers closed 1.07E-07 87624 9.38E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG . TRANSIENT EVENT I 1.00E÷00 145 T10000SW Total Loss of Service Water 1 1.0OE+00 3.80E-10 ACAAS0_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.28E-01 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.0OE-01 ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 108OE+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully I 11.00EO00 DGIANOTRUN FLAG. DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGlBNOTRUN FLAG- DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E.-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E.01 SBO TAG . STATION BLACKOUT SEQUENCE 1 11.00E+00 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPI B SW Pump B in maintenance 0.05 4.55E-02 SWTODG TAG - SW Lost to 0G (cooling) I 11.00E+00 14e TI00OOSW Total Loss of Service Water I 11.00E÷00 3.74E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LOCA) 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM001108 AOV 1108 FAILS TO OPEN OR TRANSFERS CLOSED 8.83E-04 8.83E-04 CVMM70051A VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED 0.17 1.67E-01 NOSBO TAG -NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.ODE+D0 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I1 t.00E÷00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21 E-04 1.21 E-04 147 TIOOOOSW Total Loss of Service Water I 1.00E+00 3.69E.10 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.0DE-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Tnp 2.12E-03 2.12E-03 ACTRAINS TAG - Failure of AC Train B I 1.00E÷O0

DGIBNOTRUN FLAG - OG 8 IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E-00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDO0515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.671-01 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.OE-03 1 5.OOE-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.O0E+00 TLSTRANS TAG -TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 148 TI000OSW Total Loss of Service Water I1 .00E+00 3.69E-10 ACAASO 50A FLAG - OFFSITE POWER MODE 50150ALT (CKT 751 TO BUS 12B. CKT 757 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.7E-01 RCAZD00516N Motor-Operated Valve 51 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (coeling) 1 1.00E+00 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.O0E÷00 149 TI0000SW Total Loss of Service Water 1 1.OE+00 3.69E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Resufts in St Conditions (Seal LOCA) 1 1.00E+00 ACAA5SI50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00Eu00 CVHFDSUCTN Operators Fa/ to Manually Open Suction Une Upon Loss of IA 0.02 2.40E-02 CVMM7050/A VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED 0.17 1.67E-01 DGIANOTRUN 0A FLAG - DG IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 IBAABUSBMX FLAG - Instrument Bus B on Normal Supply 1 8.99E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00Eo00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 150 TI0000SW Total Loss of Service Water 1 1.00E+00 3.695-10 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1-44E-Ol ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT787 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 151 TIS00OSW Total Loss of Service Water 1 1.00E+00 3.88E-10 ACAA 100 OX FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Otfste Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 DGtBNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.OE+00 152 TI0000SW Total Loss of Service Water 1 1.00E+00 3.68E-10 ACAA505_0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 1ZA) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0-5 6.00E-01 ACLOPRTALL Loss of All Off-She Power Following ReactorTep 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 DGIANOTRUN FLAG - DG A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.87E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is NOt Closed Due To PORV Leakage 0.97 9.67E-01 RCRZTO0430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.0012+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to 00 (cooling) 1 1.00E000 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 153 TISOOSW Total Loss of Service Water 1 1.005+00 3.60E510 ACAASO_50A FLAG - OFFSITE POWER MODE 50150ALT (CKT 751 TO BUS 128. CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Sfte Power Following Reactor Top 2.10E-03 2.1OE-03 ACTRAINB TAG - Fauore of AC Train B 1 1.00E+00 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 0.87E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.005-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1 00Eo00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 154 TIOOOOSW Total Loss of Service Water 1 1.00E+00 3.56E-10 AAAATRANSI TAG - Transient Initialing Event Which Eventually Resuets In SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50.SOA FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Une Upon Loss of IA 0.02 2.40E-02 CVMM7005/A VALVES IN INSTRUMENT AIR LINE TO SOV 142565 AND AOV 112C FAIL CLOSED 0.17 1.675-01 DGIANOTRUN FLAG - 0* 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 IBAABUSBMX FLAG - Instrument Bus B on Normal Supply 1 9.99E-01 NOSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 155 TI0000SW Total Loss of Service Water 1 1.00E+00 3.85E-10 ACAAI 00 OX FLAG -OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00

AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 0.7BE-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 156 T10000SW Total Loss of Service Water I 1.00E+00 3.65E-10 ACAA100OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All OffnS-te Power Following Reactor Trip 2.1OE-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B 1 1.001+00 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 DGO1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 I.00E+00 TRANSX TAG -TRANSIENT EVENT 1 1.00E+00 157 T10000SW Total Loss of Service Water 1 1.001+00 3.64E-10 AAAATRANSI TAG - Transient Initiating Event Whi/c Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 T

ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor rip 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E600 158 T10000SW Total Loss of Service Water I 1.00E+00 3.61E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.0OE-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Tnp 2.10E-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR a 1 HOUR 1 1.00E600 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00aE00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Last to DG (cooling) 1 1.00E+00 159 T10000SW Total Loss of Service Water 1 1.00E+00 3.40E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM00110B AOV 110B FAILS TO OPEN OR TRANSFERS CLOSED 8-83E-04 8.83E-04 CVMM00112B AOV 112B FAILS TO OPEN ON DEMAND 0.18 1.83E-01 NOSED TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.766-01 RCAZOOIRCP NO RCP SEAL COOLING FOR a 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWC)X(SUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.006-04 1.00E.04 160 T10000SW Total Loss of Service Water 1 1.00E+00 3.36E-10 ACAA50-50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsite Power Within I Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00En01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Tfip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.0OE+00 AFMMOTDAFW Failure of TDAFW pump train components 0.01 1.17E-02 DG1ANOTRUN FLAG- DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1,00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 161 710000SW Tatal Loss of Service Water I 1.00E+00 3.36E-10 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 AXTMSAFSGB SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M 0.01 1.48E-02 AXXVK9702D Manual valve 97020 transfers caosed 1.07E-07 87624 9.38E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 162 T10000SW Total Loss of Service Water 1 1.006E00 3.35E-10 AAAATRANBI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.03 0.25E601 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVHFDOSUCTN Operators Fail to Manually Open Suction Line Upon Lass of IA 0.02 2.40E-02 CVMM00112B AOV 1128 FAILS TO OPEN ON DEMAND 0.18 1.83E-01 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 IBAABUSBMX FLAG - Instrument Bus B on Nonnal Supply 1 9.99E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76EW01 RCAZ001RCP NO RCP SEAL COOLING FOR

  • 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALLLOCA SEQUENCE 1 1.00+O00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 163 T10000SW Total Loss of Service Water 1 1.00E+00 3.32E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.001+00 ACAA50O_0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 &25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM00112B AOV 1128 FAILS TO OPEN ON DEMAND 0.18 1.83E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 IBAABUSBMX FLAG - Instrument Bus B on Normal Supply 1 9.991-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR> 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.OE÷00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.80E+00 164 TIOOOESW Total Loss of Service Water 1 1.00E+00 3.15E-10 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 AXTMSAFSGA SAFW TRAIN C TO S/G A 0.0.S. DUE TO T/M 0.02 1 676-02 AXXVKg702D Manuat valve 9702D transfers cdosed I.07E-07 87624 9.38E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.08E>00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 165 TIOOOOSW Total Loss of Service Water 1 1.00E+00 3.10E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM00110B AOV 110B FAILS TO OPEN OR TRANSFERS CLOSED 8.83E-04 8.83E-04 CVMM7005/A VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED 0.17 1.67E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-E1 RCAZ001 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.08E-04 1.00E-04 166 TIOOOOSW Total Loss of Service Water I 1.00E÷00 3.06E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LOCA) 1 1.00E+00 ACAA50ESEA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CK0T767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 6.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Une Upon Loss of IA 0.02 2.40E-02 CVMM700S/A VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED 0.17 1.67E-01 DGIANOTRUN FLAG- DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 IBAABUSBMX FLAG - Instrument Bus B on Normal Supply 1 9.99E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E-00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E-00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 167 TI0000SW Total Loss of Service Water 1 1.00E+00 3.06E-10 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1-44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offste Circui 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.08E+00 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 DGIANOTRUN FLAG - DG lA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.0E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.006E00 168 TIEOOOSW Total Loss of Service Water 1 1.00E+00 3.O5E-10 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsoe Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 I.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 169 TI000OSW Total Loss of Service Water 1 1.00E+00 3.03E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.S0E+00 ACAASOE50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.0SE-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 CVMM7005/A VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED 0.17 1.67E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 IBAABUSBMX FLAG - Instrument Bus B on Normal Supply 1 9.99E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR a I HOUR 1 1_00>+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.0OE+DO SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.08E-04 SWTODG TAG . SW Lost to DG (cooling) 1 1.00E600 170 TIOOOOSW Total Loss of Service Water 1 1.80E+00 3.03E-10 ACAA100_OX FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.OOE-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 DGIANOTRUN FLAG - DOG1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00+E00 TRANSX TAG - TRANSIENT EVENT I 1.00E÷00 171 TI00SOSW Total Loss of Setvice Water 1 1.00E600 3.02E-10 ACAAI00_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.80E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of A/ Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCT1 TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 172 TI00OOSW Total Loss of Sorvco Water I 11.00E+00 2.97E-10 ACAAS E50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsite Power WOihin1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Sie Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E÷00

ACTRAINB TAG - Failure ofAC Train B 1 1,OOEo00 AFAXITOAFW TAG - TDAFW Pump operates successfully 1 1.00E-00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 I 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-E1 SBE TAG - STATION BLACKOUT SEQUENCE 1 1-OE+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 173 TIOEOOSW Total Loss of Service Water I 1 .0E÷00 2.90E-10 ACAAS0_5OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offshte Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 S.OOE-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.0.E+00 ACTRAINB TAG - Failure of AC Train B 1 1.001E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.00EO00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBE TAG - STATION BLACKOUT SEQUENCE 1 1.OOE+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.O0E÷SO 174 TISOOSW Total Loss of Service Water I 1.00E+O0 2.90E-10 ACAASO,50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsile Power Within 1 Hour 0.38 3.81EE01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOS12 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10fE-03 ACTRAINA TAG - Failure of AC Train A 1 1.O0E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PCF PLANT CAPACITY FACTOR 0.88 8.78&-01 SEO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.0OE+00 175 TIS00OSW Total Loss of Service Water I 1.00E+00 2.86E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1-01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M 0.02 1.67E-02 AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBE TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 176 TIEOOOSW Total Loss of Service Water 1 1.00E+00 2.80E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for Tl0OOOSW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1-93E+00 NOSBE TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-O1 SWAASWP1CNR FLAG - Service Water Pump PSW0t C Is Not In Operation 0.42 4.21E-E1 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMP1B SW Pump B in maintenance 0.0E 4.55E-02 SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 177 T]0OOOSW Total Loss of Service Water 1 1.00E+00 2.80E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRS3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1893E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+S0 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSWS1 B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.281-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 178 TISOOOSW Total Loss of Service Water 1 1.0OE+00 2.80E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-O6 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.OCE+00 NOSED TAG - NO STATION BLACKOUT 1 1.00E800 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD0051 SN Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 8.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 5.002-02 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-O3 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4-5$E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 179 TIS00OSW Total Less of Service Water 1 1.0OE+00 2.80E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-E6 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 NOSBO TAG - NO STATION BLACKOUT I 1.OOEv00 PCF PLANT CAPACITY FACTOR 0.88 8.76f-El RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Value (5151516) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00fE-E3 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28ff-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 180 TIOOSSSW Total Loss of Service Water 1 1.00E+00 2.78E-10 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 AXTMSAFSGB SAFW TRAIN D TO S/G B O-O.S. DUE TO TIM 0.01 1.48E-02 AXXVK9702D Manual valve 97020 transfers csosed 1.07E-07 87624 8.38E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8g76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00f-4 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 181 T0000SW Total Loss of Service Water 1 1.0E+00 2.77E-10 ACAASO50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKlT751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-E1 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsile Circuit 751 Following Reactor Tdp 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E-00 AXHFLSAFWA Failure to restore SAFW Pump Train IC to service post teeslrnaint 3.00E-03 3.00E-03 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-o4 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.OOE+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+O0 182 T10000SW Total Loss of Service Water 1 1 00E800 2.77E-10 ACAASO-50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 083 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.O0E+00 AXHFLSAFWB Failure to restore SAFW Pump Train lD to service post test/maint 3.00E-03 3.00-E03 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E-00 TRANSX TAG -TRANSIENT EVENT I 1_000+00 183 T10000SW Total Loss of Service Water I 1.00E+00 2.74E-10 AXHFDSAFWX Operators Fail to Correotly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSW01 D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT I 1.0E+00 184 T10000SW Total Loss of Service Water 1 1.08E+00 2.74E-10 ACAAS0_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXHFLSAFWE Failure to mrtow SAFW Pump Train ID to service post testimaint 3.00-E03 3.00E-03 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00>E00 185 T10000SW Total Loss of Service Water 1 1.00E+00 2.74E-10 ACAASO_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 05 5.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 AXHFLSAFWA Failure to restore SAFW Pump Train IC to service post test/maint 3.00E-03 3.008-03 DG1BNOTRUN FLAG . DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG . TRANSIENT EVENT 1 1.00E+00 186 T10000SW Total Loss of Service Water 1 1.00E+00 2.73E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E800 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 100E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 187 T10000SW Total Loss of Service Water 1 1.08E+00 2.88E-10 AXHFDSAFWX Operators Fail to Correctiy Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.0E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.78E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 188 T10000SW Total Loss of Service Water 1 1.0OE+00 2.61E-10 ACAAS_050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.258E-01 ACAZDLOSP1 Falure to Restore Ofnsite Power Wthin I Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Alt Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DG1ANOTRUN FLAG- DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 8.97E-01 DGIENOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 I.00E+00 SWMM0SWPCS FAILURES OF SW PUMP C TO START 3-28E-03 3.28E-03 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 189 T10000SW Total Loss of Service Water 1 1.00E+00 2.42E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Resuots in SI Conditions (Seal LOCA) 1 1.00E800 ACMMSST016 Transformer PXABSS016 Faults 8.40E-05 8.40E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E800 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWrODG TAG - SW Lost to DG (cooling) 1 1.00E+00 190 TIOOOOSW Total Loss of Service Water I 1.00E+80 2.32E-10 ACAA50 O0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSP1 Falure to Restore Offste Power Wohin I Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+0 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFHFDALTrTD OPERATORS FAIL TO PROVIDE COOLING TO TDAFW LUBE OIL FROM DIESEL FIRE PUMP 6.70E-03 6.70E-03 DGIANOTRUN FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01

DG1SNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 19 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.OE+00 191 TIEOOWOS Total Loss of Service Water 1 1.009E+0 2.31E-10 AXCCPDISCB Common cause failure of check valves 9700A and 9700B to open 2.18E-06 2.18E-06 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 192 TI0000SW Total Loss of Service Water 1 1.0IEu00 2.29E-10 ACAA5050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsie Ciruit 751 Following Reactor Tnp 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFLSAFWA Failure to restore SAFW Pump Train IC to service post test/maint 3.00E-03 3.00E-03 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E.01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.90E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 193 TI000OSW Total Loss of Service Water 1 1.00E+00 2.29E-10 ACAAS 50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A) 0.83 8.25$-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.08E+00 AXHFLSAFWS Failure to restore SAFW Pump Train 1D to service post test/maint 3.00E-03 3.00E-03 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00Eu00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00Eu00 194 TI0000SW Total Loss of Service Water 1 1.00E+00 2.27E810 ACAA50E50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 797 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL. Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.90E+00 AXHFLSAFWB Failure to restore SAFW Pump Train I D to service post test/maint 3.00E-03 3.0OE-03 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 19 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1I 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.08E÷00 195 TI00OOSW Total Loss of Service Water 1 1.00E+00 2.27E-10 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Sae Power Following Reactor Trip 2.10E-03 2.106-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFLSAFWA Failure to restore SAFW Pump Train IC to service post test/maint 3.00E-03 3.00E-03 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 19 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.90E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 I.08E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00+O00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 196 TI000OSW Total Loss of Service Water I 1.00E+00 2.24E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM 0.02 1-67E-02 AXTMSAFSGB SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 197 TI00SOSW Total Loss of Service Water I 1.0OE+00 2.19E-10 ACB2FIBS17 Local Faunt on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD0051 SN Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 5-00E-02 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.008E00 198 TI000SOW Total Loss of Service Water 1 1.00E+00 2.19E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E06 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B I 1.00uE00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E800 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFOPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 500OE-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00-E03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C lv maintenance 0.04 3.56E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 199 T10000SW Total Loss of Service Water 1 1.00E+00 2.19E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM 0.02 1.67E-02 AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TO TIM 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 200 TIOOOSOW Total Loss of Service Water 1 1.00E+00 2.19E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M 0.02 1.67E-02 AXTMSAFSGB SAFW TRAIN D TO S/G B 9.0.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E-00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TRANSX TAG - TRANSIENT EVENT I 1.00E800 201 T10000SW Total Loss of Service Waler 1 1.00E+00 2.14E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIO0OOSWand Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00

NOSBO TAG - NO STATION BLACKOUT 1 1.0OE+00 PCF PLANT CAPACITY FACTOR 0.85 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CNR FLAG - Service Water Pump PSWOIC Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-G4 1.14E-04 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.001+00 202 TIOOOOSW Total Loss of Service Water 1 1.OOE+0O 2.14E-10 ACE2FIBS17 Local Fault on 400 VAC Bus 17 1.01E-06 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.gOE+0g NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDOO515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA W/n 3 Min 0.05 5.00E-02 RCRZTO431C PORV PCV-431C Fails To Reseat After Steam Relief 5.OE-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+O0 203 TI000SW Total Loss of Seivice Water I 1.00E+00 2.14E-10 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.0OEo00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDOO0516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA W/in 3 Min 0.05 0.003E-02 RCRZT0O430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 204 TI0000SW Total Loss of Service Water 1 1.00E+00 2.14E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 101E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1 00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fall To Close PORV Block Valve (515/516) To Terminate LOCA W/ln 3 Min 0.05 5.00E-02 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Serorvce Water Pumps To Start 1.14E-04 1.14E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00OE+00 205 TIOO0SW Total Loss of Service Water 1 1.00E+00 2.14E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 I 8.85E-03 ACTRAINA TAG - Failuro of AC Train A 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZTO0430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 206 T100000SW Totat Loss of Service Water 1 1.00E+00 2.11E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 I.000000 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 IAAACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9.50E-01 IAHFDCSA04 OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR 5 I HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E÷00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 207 T10000SW Total Loss of Service Water 1 1.00E+00 2.09E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corected for TIOOOOSWand Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SWto I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1 B Is In Operation 0-58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1 D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.281-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPI C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 208 T10000SW Total Loss of Service Water 1 1.00E+00 2.09E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.000000 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION T FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor rip 2.100-03 2.10E-03 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 IAAACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9.50E-01 IAHFDCSAO4 OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR 0 1 HOUR 1 1.00E÷00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.O0E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 209 T10000SW Total Loss of Service Water 1 1.00E+00 2.05E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIOOOOSWand Soei Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 CoTrection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0158 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+O0 210 T1000OSW Total Loss of Service Water 1 1.00E+00 2.05E-10 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIOO0OSWand Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to I 1.93E+00O NOSBO TAG - NO STATION BLACKOUT 1 1,00E+OO PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-0-4 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2-47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+O00

211 TI0000SW Total Loss of Service Water I 1.00E+00 2.03E-10 ACMMSST014 480 VAC Bus 14 Transformer PXABSS014 Faults 8.40E-05 8.40E-05 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.291-02 DGlANOTRUN FLAG. DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E-00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 212 T10000SW Total Loss of Service Water 1 1.00E+00 2.03E-10 ACMMSST018 Transformer PXABSS016 Faults 8.40E-05 8.40E-05 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump I C train 0.02 2.29E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E÷00 213 TI0000SW Total Loss of Service Water 1 1.00E+00 2.03E-10 AXHFLSAFWA Failure to restore SAFW Pump Train 1C to service post tlesUmaint 3.OOE-03 3.00E-03 AXMMSGBSAF Failure of SAFW injection line to SIG B 6.39E-04 8.39E-04 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 121E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 214 TI700OSW Total Loss of Service Water I 1.00E+00 2.01E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACMMSST018 Transformer PXABSS016 Faults 8.40E-05 0.40E-05 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSEO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.0E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E-00 215 T10000SW Total Loss of Service Water 1 1.00E+00 1.97E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINE TAG - Failure of AC Train B I 1.00E+00 AXTMSAFSGA SAFW TRAIN C TO SIG A O.O.S. DUE TO T/M 0.02 1.671-02 AXTMSAFSG8 SAFW TRAIN D TO S/G B OO.S. DUE TO T/M 0.01 1.48E-02 NOSBE TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 TRANSX TAG - TRANSIENT EVENT 1 1-00E+00 216 T10000SW Total Loss of Service Water I 1.00E+00 1.93E-10 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZOLOSPI Failure to Restore Offsie Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFHFDAL'TD OPERATORS FAIL TO PROVIDE COOLING TO TDAFW LUBE OIL FROM DIESEL FIRE PUMP 8.70E-03 6.70E-03 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 997E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SB TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.000-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 10OE+00 217 Ti0000SW Total Loss of Service Water I 1.00E+00 1.82E-10 ACB2FIBS17 Local Faul on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINE TAG - Failure of AC Train B 1 1.00E000 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDD0515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA WAn 3 Min 0.05 5.00E-02 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 I 5000E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 218 T10000SW Total Loss of Service Water 1 1 00E+00 1.92E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 0-06 1 8.850-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.761-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (5150516) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALLLOCA SEQUENCE 1 1.00E+00 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 219 T10000SW Total Loss of Service Water 1 1.00E+00 1.91E-10 AXCCPDISCB Common cause failure of check valons 9700A and 9700B to open 2.1 E-06 2.18E-06 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00-E04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.OSE+00 220 T10000SW Total Loss of Service Water 1 1.00E+00 1.85E-10 ACAA5M050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZOLOSPt Failure to Restore Offsite Power Wirtin 1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.010-06 1 8.85E-03 ACB2FTES18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E000 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 OG18NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTODG TAG - SW Lost to 00 (cooling) 1 1.00E+00 221 TI0000SW Total Loss of Service Water 1 1.00E+00 1.85E-10 ACAAS0_50A FLAG - OFFSITE POWER MODE 50/00 ALT (CKT 751 TO BUS 128. CKT 787 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSP1 Failure to Restore Ofsitle Power Within 1 Hour 0.38 3.81E-01

ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-O3 ACB2FTBS1 7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-O5 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Sete Power Following ReactorTrp 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.001+00 ACTRAINB TAG - Failure of AC Train B 1 t.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 PCIF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 222 TI0OO$SW Total Loss of Service Water 1 1.00E+00 182E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01 E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXXVN09728 3 way valve 9728 fails to operate 1.00E-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+O0 PCF PLANT CAPACITY FACTOR 0g88 8.76E-01 SWMMOSWPBS FAILURES OF SW PUMP S TO START 3.28E-03 3.28E-03 SWrMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00>E00 223 T1000OSW Total Loss of Service Water 1 1+008E00 1.79E-10 AAAATRANSI TAG - Transient Initiating Event Whichi Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCIF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOCIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCVC04803 Service Water Pump PSW01C Discharge Check Valve 4603 Fails To Close On Demand 5+84E-04 1 5.84E-04 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 224 TIO000SW Total Loss of Service Water 1 1.00E+00 1.75E-10 AXMMSAFWPD Failure of SAFW Pump 1 D Train 0.02 2.29E-02 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM 0.02 1.87E-02 AXTMSAFWAB SAFW cross-connect line out-of-service for maintenance 4.33E-03 4233E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCIF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 225 TI1000SW Total Loss of Service Water 1 1.00E+00 1.75E610 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAAS0 50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Top 2.12E-03 2.12E-03 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 LAACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9.50E-01 IAHFDCSA04 OPERATORS FAILTO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.0OE-01 NOSBO TAG - NO STATION BLACKOUT 1 1006E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E801 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E800 SWC)XXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 226 TI0000SW Total Loss of Service Water 1 1.00E+00 1.73E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-See Power Following Reactor Trip 2.10E-03 2.10-E03 CVHFDSUCTN Operators Fail to Manually Open Suction Line Upon Loss of IA 0.02 2.40E-02 IAAACSA02R FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA 0.95 9850E-01 IAHFDCSA04 OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8,76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 227 T10000SW Total Loss of Service Water 1 1.00E+00 1.73E-10 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 126. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-O1 ACLOPRTALL Loss of All Off-Sie Power Following Reactor Trip 2.10E-03 2-10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00>E00 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.00E-01 AFTMOTDAFW TDAFW Pump Train out-of-service for maintenance 0.02 1.90E-02 DG1ANOTRUN FLAG - DO;1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1008+00 228 TIOOOOSW Total Loss of Service Water 1 1.00E+00 1.68E.10 ACMMSST014 480 VAC Bus 14 Transformer PXABSS014 Faults 8.40E-05 8.40E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9897E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCIF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E600 TRANSX TAG - TRANSIENT EVENT 1 1 00E+00 229 T10000SW Total Loss of Service Water 1 1.00E+00 1.68E-10 ACMMSST016 Transformer PXABSS016 Faults 8.40E-05 840E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCIF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 230 TI00SOSW Total Loss of Service Water 1 1.00E+00 1.801-10 AXHFLSAFWA Failure to restore SAFW Pump Train IC to service pest test/maint 3.00E-03 3.00E-03 AXMMSGBSAF Failure of SAFW injection line to S/G B 6.39E-04 6.38E-04 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 231 T1000$SW Total Loss of Service Water 1 1.00E+00 1.58E-10 AXHFLSAFWB Failure to restore SAFW Pump Train ID to service pest test/maint 3.00E-03 3.00E-03 AXMMSGASAF Failure of SAFW injection line to S/G A 4.976E-04 4.97E-04

NOSBO TAG - NO STATION BLACKOUT 1 I.0OE>00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT I 1.00E-00 232 TI0000SW Total Loss of Service Water 1 1.001E+O0 1.58E-10 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXTMSAFSOB SAW* TRAIN D TO IOG B O.O.S. DUE TO T/M 0.01 1.480-02 AXTMSAFWAB SAFW cross-cornect line out-of-serurce for maintenance 4.33E-03 4.33S-03 NOSBO TAG - NO STATION BLACKOUT 1 1l00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E>00 233 TI0000SW Total Loss of Service Water 1 1.OE+O0 1.458E-10 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 AXTMSAFSGA SAFW TRAIN C TO S/G A DO..S. DUE TO TIM 0.02 1.678-02 AXTMSAFWAB SAFW cross-connect line out-of-service for maintenance 4.33E-03 4.33E-03 NOSO TAG - NO STATION BLACKOUT 1 1.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.000-04 TRANSX TAG - TRANSIENT EVENT 1 1.0OE+00 234 TI0000SW Total Loss of Service Water 1 1.00E+00 1.438-10 ACAA50-50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.001-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.108-03 ACTRAINA TAG - Failure of AC Train A I 1.00E÷00 ACTRAINB TAG - Failure of AC Train B 1 1.DOE+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.00-E01 AFTMOTDAFW TDAFW Pump Train out-of-service for maintenance 0.02 1.90E-02 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.978-01 DGIBNOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANTCAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E-00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODOG TAG - SW Lost to DG (cooling) 1 1.00E+00 235 TI000OSW Total Loss of Service Water 1 1.00E+00 1.40E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85lt-03 ACTRAINB TAG - Failure of AC Train B 1 1.08E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 0.78-E01 RCAZSO1RCP NO RCP SEAL COOLING FOR v 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+v0 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWCVC04602 Service Water Pump PSW01 Discharge Check Valve 4602 Falls To Close On Demand l.84E-04 1 5.84E-04 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 238 TIOOOOSW Total Loss of Service Water 1 1.,OE+00 1.36E-10 ACMMMCCO1C 480 VAC Motor Control Center MCCC Faults 5.82E-05 5.82E-05 AXMMSAFWPO Failure of SAFW Pump 1 D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 237 TI00COSW Total Loss of Service Water 1 1 00vE00 1.36E-10 ACMMMCCOIL 480 VAC Motor Control Center MCCL Fauots 5.62E-05 5.82E-05 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E1200 238 TI0000SW Total Loss of Service Water I 1.00E+00 1.36E810 ACMMMCCO1D 480 VAC Motor Control Center MCCD Faults 5.62E-05 5.62E-08 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 239 TIO000SW Total Loss of Service Water 1 1.00E>00 1.36E-10 ACMMMCC01M 480 VAC Motor Control Center MCCM Faults lt62E-05 5.62E-05 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 240 TI0000SW Total Loss of Service Water 1 1.00E+00 1.31E-10 AXHFLSAFWB Failure to restore SAFW Pump Train 1D to service pest test/maint 3.00E-03 3.00E-03 AXMMSGASAF Failure of SAFW injection line to S/G A 4.97E-04 4.97E-04 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.0OE-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E÷00 241 TIOOOSW Total Loss of Service Water 1 1.00E+00 1.28E-10 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXTMSAFSGB SAFW TRAIN D TO SIG B O.O.S. DUE TO TJM 0.01 1.48E-02 AXTMSAFWAB SAFW cross-connect line out-of-service for maintenance 4.338-03 4.33E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 242 T10000SW Total Loss of Service Water 1 1.00E+00 1.25E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.O0E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 243 TIOO8OSW Total Loss of Service Water I 1.00E+00 1.25E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1-01E-08 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANTCAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS I 1.o0E÷00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPSS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03

244 TI0000SW Total Loss of Service Water 1 1.00E+00 1.24E-10 MLO TAG - MEDIUM LOCA SEQUENCE 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.87E-01 RCAZD00516N Moltr-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFOPLOCA Operators Fail To Close PORV Block Vatve (5151518) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.02E-03 1 5.00E-03 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.OE-03 1 5.00E-03 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TLMTRANS TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES I 1.00E+00 245 Ti0000SW Total Loss of Service Water I 1.00E+00 1.23E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In St Conditions (Seal LOCA) I 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E-00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 5SLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAASWP1DR FLAG - Service Water Pump PSW01 0 Ic tn Operation 0.58 5.79E-01 SWCVC04804 Service Water Pump PSWO1D Discharge Check Valve 4804 Fails To Close On Demand 5.84E-04 1 5.84E-04 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT 1 1.005+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 246 TI0000SW Total Loss of Service Water 1 1.005+00 1.21-110 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAASOL50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactr Trip 2.12E-03 2.12E-03 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 CVMMPCH1AF CHARGING PUMP PCH01A FAILS TO RUN 1.31E-03 1.311-03 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Caose Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 247 TI0000SW Total Loss of Service Water 1 1.00E+00 1.20E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAASO 50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Sie Power Fotlowing Reactor Tdip 2.102-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 CVMMPCHIAF CHARGING PUMP PCHO0A FAILS TO RUN 1.315-03 1.31E-03 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR , 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.OOE+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 248 TI000OSW Total Loss of Service Water 1 1.00E+00 1.19E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 .85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXXVN09728 3 way valve 9728 fails to operate 1.00E-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCVC04603 Service Water Pump PSWS1C Discharge Check Valve 4803 Fails To Close On Demand 5.84E-04 1 5.84E-04 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 249 TI00OOSW Total Loss of Service Water I 1.00E+00 1.1SE-10 ACAA10 .OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZDLOSPI Failure to Restore Offslel Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-S8e Power FolokMng Reactor Trip 2.1OE-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 AFTMOTDAFW TDAFW Pump Train oat-of-service for maintenance 0.02 1.90E-02 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 I 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

$50 TAG - STATION BLACKOUT SEQUENCE 1 1.005+00 SWCCIPUMPSR Common Caose Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 250 TI0000SW Total Loss of Service Water 1 1.00E+00 1.13E-10 ACMMMCC01C 480 VAC Motor Control Center MCCC Faults 5.62E-05 5.625-05 AXMMSAFWPD Faire of SAFW Pump ID Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION QNITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 251 TI0000SW Total Loss of Service Water 1 1.00E+00 1.13E-10 ACMMMCC0IL 480 VAC Motor Control Center MCCL Faults 5.62E-05 5.82E-05 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT I 1.00E+80 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTl TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.005+00 252 TI0OO0SW Total Loss of Service Water 1 1.00E+00 1.13E-10 ACMMMCCOI D 480 VAC Motor Control Ceoter MCCD Faults 5.62E-05 5.62E-05 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWC)CXSUCTI TOTAL FAILURE OF COMMON 5W/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 253 TIO000SW Total Loss of Service Water I 1.00E+00 1.13E-10 ACMMMCC01M 480 VAC Motor Control Center MCCM Faults 5.62E-05 5.82E-05 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SwaOSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 254 110000SW Total Loss of Service Water 1 1.00E+00 1.08E-10 AAAATRANSI TAG - Transient Initiating Event Which Eventualay Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.602-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00

SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALLSMALL LOCA SEQUENCE I 11.00E00 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 SWTMPUMPIB SW Pump S in maintenance 0.05 4.55E-02 255 TI0000SW Total Loss of Service Water 1 1.00E+00 1.07E-10 ACAA5S050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following ReactoriTdp 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure ofAC Train B I 1.00E+00 AFAZFAILXX Non-Elec Failure of aDlMDAFW pumps oindependentof AF300) 0.1 1.00E-01 AFMMOTDAFW Failure of TDAFW pump traie components 0.01 1.17E-02 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

$50 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 256 TIOOOOSW Total Loss of Service Water I 1.00E+00 1.045-10 ACAAS0_SOA FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsie Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Losw of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Faoure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DG1ARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 0.03 3.00E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.005-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SO TAG - STATION BLACKOUT SEQUENCE 1 1.005200 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00+200 257 TI00OOSW Total Loss of Service Water 1 1.00E+00 1.045-10 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offste Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.005-01 ACLOPRTALL Loss of ANOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFHFLTDAFW Failure to restore TDAFW pump train to service post test/maintenance 3.00E-03 3.00e-03 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.005+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.215-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 258 TIOOOOSW Total Loss of Service Water I 1.00E+00 1.02E-10 MLO TAG - MEDIUM LOCA SEQUENCE 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.671-01 RCAZD00518N Motor-Opurated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fad To Close PORV Block Valve (515/518) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Reitef 5.00E-03 1 5.001-03 RCRZT0431C PORV PCV-431C Fais To Reseal After Steam Relief 5.00E-03 1 5.00E-03 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TLMTRANS TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES 1 1.00E+00 259 T10000SW Total Loss of Service Water I 1.00E+00 1.02E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 AXCCSSAFWA Common couse failure of SAFW Pumps 1C and ID to start 8.79E-05 0.79E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 263 TIO000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 AAAATRANSI TAG - Transient Initiating Event Whlich Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 AAA..OOSX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128) 0.02 1.501-02 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.5E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure ofAC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1SNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.005+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOAs 1 1.00E500 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00+E00 SVWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SWPumpC In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circul after failure of first 0.1 1.00E-01 264 TIO000SW Total Loss of Service Water I 1.00E+00 0.00+E00 AAAATRANSI TAG - Transient Initialing Event Which Eventualy Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA0M100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 126) 0.02 1.05E-02 ACS2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ANOff-Sihe Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.005+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.005+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALLSMALL LOCA SEQUENCE 1 1.00E+00 SWTMIPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.05E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E500 265 T10000SW Total Low of Service Water 1 1.00E+00 O.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA0100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.501-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offslte Circuit 751 Folowlig Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure ofAC Train B 1 1.00E+00 DGIANOTRUN FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 19 AND 17 1 9.97E-01

TAG - NO STATION BLACKOUT 1 1.00E+00 NOSBO 0.88 8.788-01 PCF PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + 1 HOUR 1 1.00E+80 RCAZ001RCP TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E+80 SEALLOCA SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 1.21E-04 1.21E-04 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1 1.00E+80 Sw'rODG TAG - SW Lost to D0 (cooling) 0 0.OOE+00 AAAA FACTOR TO ELIMINATEUV AND ILLOGICAL CUTSETS 0.1 1.002-01 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 1 1.00E+00 0.OOE+00 268 TI0000SW Total Loss of Service Water 1 1.00E+00 AAAATRANSI TAG - Trensintl Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 0.02 1.50E-02 ACAA0O100X FLAG - OFFSITE POWER MODE 0/100 (CKT 781 SUPPLYING BUSES IA AND 12B) 0.8 8.008-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 2.12E-03 2.121-03 ACLOPRT-51 Loss of Offste Circuit 751 Following Reactor Ttip 1 1.00E+00 ACTRAINA TAG - Failure of AC Train A 1 1.005+00 ACTRAINS TAG - Failure of AC Train B 1 9.97E-01 DGlANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.78E-01 PCF PLANT CAPACITY FACTOR 1 1.00E+00 RCAZ0O1RCP NO RCP SEAL COOLING FOR + I HOUR 1 1.008E00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR) 1.00E-04 1.00E-04 SWCo(SUCTI 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling) 0 0.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0.1 1.00E-01 ACHFDRCOFF Failure to recover second oftsite power circuit after failure of first 1 1.00E+00 0.00E+00 267 TI0000SW Total Loss of Service Water 1 1.00E+00 AAAATRANSI TAG - Transient Initiaing Event Which Eventually Results in SI Conditions (Seal LOCA) 0.02 1.50E-02 ACAAOJL0OX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.5 5.00E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 2.10E-03 2.102-03 ACLOPRTALL Loss of At Off-Site Power Folfowing Reactor Trip 1 1.00E+00 ACTRAINA TAG - Fauure ofAC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 9.97E-01 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 1.80E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 1 1.00E+00 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E2+0 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1.21E-04 1.21E-04 SWCCIPUMPSR Corrmnon Cause Failure Of Service Water Pumps To Run 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling) 0 0.001+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 1 1.00E+00 0.008+00 268 T10000SW Total Loss of Service Water 1 1.008+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 0.02 1.50E-02 ACAA0J100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)

CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.8 5.00E-01 ACLOPNOSI2 2.108-03 2.10E-03 ACLOPRTALL Loss OfAlI Off-Sne Power Following ReactorTrip 1 1.00E+00 ACTRAINA TAG - Failure of AC Train A 1 1.008+00 ACTRAINB TAG - Failure of AC Train B 1 9.97E-01 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 1 1.00E+00 RCAZ001RCP NO RCP SEAL COOLING FOR u 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWCXXSUCTI 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling) 0 0.008+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 1 1.008+00 0.00E+00 269 TI0000SW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 0.14 1.44E-01 ACAAI00 0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)

ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 &.001-01 2.12E-03 2.11212-03 ACLOPRT767 Loss of Offsie Circuit 767 Following Reactor Trip ACTRAINA TAG - Failure of AC Train A 0 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 I 9.97E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 1 1.00E+00 RCAZ00IRCP NO RCP SEAL COOLING FOR + I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SEALLOCA I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1.14E-04 1.14E-04 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start I 1.00E+00 SWTODG TAG - SW Lost to DG (cooling) 0 0.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0.1 1.0012-011 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first I 1.00E+00 0.00E+00 270 T10000SW Total Loss of Service Water I 1.00E+O0 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 0.14 1.44E-01 ACAA100_0X FLAG - OFFSITE POWER MODE 10010(CKT 767 SUPPLIES BUSES 12A AND 128) 1.01E-156 I 8.85E-03 ACB2FIBS17 Local Fault on 480 VAC Bus 17 0.5 5.00E-0t ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 2.12E-03 2.12E-03 ACLOPRT767 Loss of Offsihe Circuit 787 Following Reactor Trip TAG - Failure of AC Train A 1 1.00E+00 ACTRAINA TAG - Failure of AC Train B 1 1.00E÷00 ACTRAINB 1 9.97E-01 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - 00 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT 1 1.00E+00 NOSBO 0.88 8.76E-01 PCF PLANT CAPACITY FACTOR 1 1.00E+00 RCAZ00IRCP NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOOAs 1 1.00E+00 SEALLOCA TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E÷00 SSLO FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPAS SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMP1C 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling)

FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 AAA Failure to recover second offsite power circuit after failure of first 0.1 1.00E-011 ACHFDRCOFF 1 1.00E+00 0.0012+00 271 T10000SW Total Loss of Service Water 1 1.00E÷00 AAAATRANSI TAG -Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)

FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACAA100_OX 1.01E-06 1 8.85E-03 ACB2FIBS17 Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-011 ACLOPNOSI2 Loss of Offste Circuit 767 Following ReactorTnp 2.12E-03 2.12E*03 ACLOPRT767 TAG - Faiure of AC Train A I 1.00E+00 ACTRAINA TAG - Failure of AC Train B I 1.00E+00 ACTRAINB 1 9.97E-01 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.07E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 NOSBO TAG - NO STATION BLACKOUT 1 1.0012+00 PLANT CAPACITY FACTOR 0.88 8.78E-01 PCF NO RCP SEAL COOLING FOR + 1 HOUR I 1.00E÷00 RCAZO01RCP SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00

SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offste power circuit after failure of first 0.1 1.00E-01 272 TI0000SW Total Loss of Service Water 1 1.00E+00 0.OSE+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA1 80X FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-00 1 8.85E-03 ACLOPNOSt2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsfie Circuit 767 Following Reautor Trip 2.128-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.001+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 1I I 9.97E-01 DGIBNOTRUN FLAG - 0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.001+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00+E00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 273 T10000SW Total Loss of Service Water 1 1.00+E00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 AC52FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.68-E03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of M Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG- DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.07E-01 DGIBNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 6.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure of Service Water Pumps To Start 1.14E-04 1.14E-04 SWrODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 274 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Inilating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAAI00O0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 120) 0.14 1.44E-01 ACB2FIBS17 Local Fault 0n 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of At Off-Site Power Following Reactr Trip 2.10E-03 2.10t-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E÷00 ACTRAINS TAG - Failure of AC Train B 1 1.00E00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGl BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS O 0.00E+00 275 T10000SW Total Loss of Service Water 1 1.008200 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Alt Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 16 1 9.97E-01 DG1 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.001+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWVMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.281-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.131-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E200 276 T10000SW Total Loss of Service Water 1 1.00E+00 0.OOE+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100.0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of An Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ00IRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E÷00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTIMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - 8W Lost to DG (cooling) I 1.00E+00 AAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E-00 277 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventualty Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAAI00O0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 6.88E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.121-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGlANOTRUN FLAG -DG0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00

SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.008+00 ACHFDRCOFF Failure to recover second offsie power circuit after failure of first 0.1 1.00E-01 278 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seal LOCA) 1 1.00E+00 ACAA100LOX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.440-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.8 5.00E-01 ACLOPRT787 Loss of Offaste Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E-00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DGO IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWT'MPUMP1B SW Pump B in maintenance 0.05 4.550-02 SWTODG TAG - SW Lost to DO (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Fauure to recover second offsite power circuit after failure of first 0.1 1.00E-01 279 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initatinrg Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA1 00_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT/87 Loss of Offsie Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure ofAC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DOG1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGlBNOTRUN FLAG - DOGB IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.000+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIB SW Pump B in maintenance 0.08 4.65E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 280 TI0000SW Total Loss of Service Water 1 1.00E+00 0.000+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.101-03 2.108-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.O8+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.970-01 DGIBNOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSOB TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FORv I HOUR 1 1.000+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.008+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AMMA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 281 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Whticl Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/S (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Los of All Off-Site Power Following Reactor Trip 2.101-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E÷00 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DOGB IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E-00 PCF PLANT CAPACITY FACTOR 0.88 8.T76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 0 10.00E+00 OSWvIMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPI B SW Pump Bin mainatenance 0.05 4.5512-02 SWTODG TAG - SW Lost to DOG(cooling) 1 1.0012+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 282 TI0S0SW Total Loss of Service Water I 1.00E+00 O.O0E+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA100.OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01 E-08 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-011 ACLOPRTALL Loss of AM Off-Site Power Following Reactor Trip 2.101-03 2.101-03 ACTRAINA TAG - Faiure ot'AC Train A 1 1.00E+00 ACTRAINB TAG - Failure ofAC Train B I 11.00E+.00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.0012+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15SE-03 7.15E-03 SWTODG TAG - SW Lost to DG (cooling) I 1.00E-D00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 283 TI7000SW Total Loss of Service Water I 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) I 11.00E+00 ACAA100_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 DG1ANOTRUN FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 11.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.7SE-01 RCAZOO1RCP NO RCP SEAL COOLING FOR >1 HOUR 1 1.00E+O0

SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 SWTODG FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 AAAA ACHFDRCOFF Failurm to recover second offsite power circuit after failure of first 0.1 l.00E-01 264 TICOOOSW Total Loss of Service Water 1 1.00E+00 0.00E-00 TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 AAitATRANSI 0.14 1.44E-01 ACAA100_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128)

CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPNOSI2 ACLOPRT767 Loss of Offiste Circuit 767 Following Reactor Trip 2.12E-03 2.121-03 TAG - Failure of AC Train A 1 1.00E+00 ACTRAINA TAG - Failure of AC Train B 1 1.00E+00 ACTRAINB FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIANOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGIBNOTRUN NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.768E-01 PCF 1 1.00E+00 RCAZ001RCP NO RCP SEAL COOLING FOR > I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SEALLOCA TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SSLO SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.002E-04 1.00E-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 SWTODG FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 AAAA Falure to recover second offsite power circuit after failure of firt 0.1 1.00E-01 ACHFDRCOFF 285 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seat LOCA) 1 1.00E+00 FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACAA1I0_0X 0.5 5.00E-01 ACLOPNOSt2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRT687 Loss of Offsite Circuit 767 Following Reactor Tdp 2.12E-03 2.12E-03 TAG - Failure of AC Train A 1 1.00E+00 ACTRAINA TAG - Failure of AC Train B 1 1.00E+00 ACTRAINB 1 9.97E-01 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 DGt BNOTRUN TAG - NO STATION BLACKOUT 1 1.00E+00 NOSBO PLANT CAPACITY FACTOR 0.86 8.76E-01 PCF RCHFD00RCP Operators Fall to Trp RCPS After Loss of Support Systems 0.02 1.61E-02 TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SEALLOCA TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SSLO SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 SWTODG FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 AAAA Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 ACHFDRCOFF Total Loss of Service Water I 1.00E+00 0.00E+00 286 TI0000SW TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seao LOCA) 1 1.000E00 AAAATRANSI ACAA100..OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPNOS12 ACLOPRT767 Loss of Offsite Circuit 767 Following ReactorTrip 2.12E-03 2.12E-03 TAG - Failure of AC Train A 1 1.00E+00 ACTRAINA TAG - Failure of AC Train B 1 1.00E+00 ACTRAINB FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIANOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGt BNOTRUN TAG - NO STATION BLACKOUT 1 1.00E+00 NOSBO PLANT CAPACITY FACTOR 0.88 8.78E-01 PCF RCHFDOORCP Operators Fail to Trip RCPs After Loss of Support Systems 0.02 1.61E-02 TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SEALLOCA SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXOSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 0 0.000+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 Total Loss of Service Water 1 1.000+00 0.00E+00 287 TI0000SW TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E000 AAAATRANSI ACAA100 0X FLAG - OFFOITE POWER MODE 100/S (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 0.5 5.00E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of At Off-Site Power Following Reactor Tdp 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG- DG 1AIS NOT RUNNING AND TIED TO BUSES 14AND 18 1 6.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 DGIBNOTRUN NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 0.88 8.7BE-01 PCF PLANT CAPACITY FACTOR RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.OlE+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.0OE000 TAG - SMALL SMALL LOCA SEQUENCE I 1.00E÷00 SSLO Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWCCIPUMPSR 1 1,00E÷00 SWTODG TAG - SW Lost to DG (cooling) 0O0.0OE+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS I 1.00E+00 O.00E+00 288 TI0000SW Total Loss of Service Water I 1.00E+00 AAAATRANSI TAG - Transient In/Oating Event Which Eventually Results in SI Conditions (Seal LOCA)

FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAA1 OOX CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPNOSI2 Loss of At Off-Site Power Following Reactor Trip 2.10E-03 2.10OE-03 ACLOPRTALL TAG - Failure of AC Train A I 11.00E+00 ACTRAINA TAG - Failure of AC Train B I 1.00E+00 ACTRAINB FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 8.97E-01 DGIANOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 DGIBNOTRUN I 1.00E+00 NOSBO TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR 0.88 8.76E-01 PCF NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 RCAZ001RCP TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SEALLOCA TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SSLO 1.00E-04 1.00E-04 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)

TAG - SW Lest to DG (cooling) I 1.00E+O0 SWTODG AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water I 1.00E+00 0.0012+00 289 T10000SW I 1.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 0.14 1.44E-01 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12AAND 12B)

ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5,00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure OfAC Train A I 1.00E+00 ACTRAINA ACTRAINB TAG - Failure of AC Train B I 1.00E+00 DGlANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 0.97E-01 DGIBNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 8.97E-011 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFDOORCP Operators Fail to Trip RCPs After Loss of Support Systems 0.02 1.61E-02 TAG - TRANSIENT INDUCED SEAL LOCAs I 11,00E+00 SEALLOCA SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCCIPUMPFR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 1 1,0012+00 SWTODOG TAG - SW Lost to DG (cooling)

FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0O0.00E+00 AAAA 290 TI0000SW Total Loss of Service Water I 1.00E÷00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 ACAA100_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01

ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E÷00 ACTRAINB TAG - Failure of AC Train B 1 1.OOE+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGlBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFDOORCP Operators Fall to Trip RCPs After Loss of Support Systems 0.02 1.61E-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALLSMALL LOCA SEQUENCE 1 1.001+00 BWCXXOUCTI TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost In DG (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.05E+00 291 TI7000SW Total Loss of Service Water 1 1.00E+00 5.00*E00 AAAATRANSI TAG - Transient Initiatng Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACAASOL50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAAO 50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B) 0.02 1.70E-02 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOOI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTSI-1 Loss of Offsite Circuit 751 Following Reactor Trip 2.125-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.05E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR u 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.005+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWVTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - 0W Lost to0G (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.OOE+00 ACHFDRCOFF Failure to recover second otfsite power circuit after failure of first 0.1 1.00E-01 292 710000SW Total Loss of Service Water 1 1.005+00 5.005+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seal LOCA) 1 1.00E+00 ACAAOS_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAA50M50N FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 125) 0.02 1.70E-02 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-08 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offtsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 001 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1A " SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 5.00E+00 ACHFDRCOFF Failure to recover second olfite power circuit after failure of first 0.1 1.005-01 293 TI0000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAAO590A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAAS*SON FLAG - OFFSITE POWER MODE 00/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 125) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following ReactorTrip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.005+00 DGlANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG- DG- IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.80 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALLLOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE LIVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-011 294 TI0000SW Total Loss of Service Water I 11.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50-50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACAASO-50N FLAG - OFFOITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 125) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-011 ACLOPRT751 Loss of Offsthe Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B I 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG5 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-011 NOSBO TAG - NO STATION BLACKOUT I 1.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTlOOG TAG - SW Lost to DG (cooling) I 11.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 295 TI0000WS Total Loss of Service Water I 11.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) I 11.00E+00 ACAA50 50A FLAG - OFFSFTE POWER MODE 501/0 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-011 ACAA50_SON FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B) 0.02 1.70E.-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-011 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E÷00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.(0)E+00

-WCCIPUMPSR Common Cause Failure Of Seroice Water Pumps To Run 1.21E-04 1.21 E-04 SWTODG TAG - SI Lost to DG (cooling) I 1.ODE+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 O.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of irst 0.1 1.00E-01 298 T10000SW Total Loss of Service Water 1 1.0012+00 0.00E+00

AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E>00 ACAASO..OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 787 TO BUS 12A) 0.83 8.28E-01 ACAAS. ON FLAG - OFFSITE POWER MODE S0/50NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT787 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.io0E00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offitse power circuit after failure of first 0.1 1.002-01 297 TIOOO0SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACB2FIBS18 Local Fault on 480 VAC Bus IB 1.01E-06 1 8.858-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ANOff-Site Power Following Reactor Trip 2.108-03 2.10E-03 ACTRAINA TAG - Failloe of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGt BNOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED 0.12 1.23E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00>E00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.008+00 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazl tce and Loss of SW (32/2052 hrs) 0.02 1.88E-02 SWTODG TAG - SW Lost 1o DG (cooling) 1 1.00>E00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 298 TI0000BW Total Loss of Service Water 1 1.00E>00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00>E00 ACAAS)0A FLAG - OFFSITE POWER MODE SO/SO ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-00 1 8.85E-03 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Site Power Fotlowing Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00>E00 ACTRAINS TAG - Failure of AC Train B 1 1.00>E00 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGlBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.978-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ00I RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.008+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.008+00 SWTODG TAG - SW Lost In DG (cooling) 1 1.00E+80 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 299 TI0000SW Total Loss of Service Water 1 1.008+00 0.008+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAASO_50A FLAG - OFFSITE POWER MODE S505 ALT (CKT 761 TO BUS 128. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 I.018E-f I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT'751 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.128-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E800 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWrMPUMPIA SW Pump Ain maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 0 1.00E+00 300 TI0000SW Total Loss of Service Water I 1.00E+00 O.O8E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 11.0012+00 ACAAS0 5OA FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8t.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.0111-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-011 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10DE-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 11.00E+00 ACTRAINB TAG - Failure of AC Train B 1 11.00E+00 DGIANOTRUN FLAG- DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIENOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR >1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 11.11412-041.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 301 TI000OSW Total Loss of Service Water I 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventualty Results in SI Conditions (Seal LOCA) I1 1.00E+00 ACAAS0L.50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-011 ACLOPRTALL Loss of At Off-Site Power Following Reactor Trip 2.10DE-03 2.110E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGI BNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.5SE-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 302 TIO000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00

ACAASQOSOA FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.010-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.101-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - 0G 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 8.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.001>00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 303 TI0000SW Total Loss of Service Water 1 1.00E+00 0.80E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACAAS0-5OA FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO STCONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ANlOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.000+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 1 9.87E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.000+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.000+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 O.00E+00 304 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Inhtating Event Which Eventualty Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAAS0_50A FLAG - OFFSITE POWER MODE 50/SB ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 6.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Faloure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG -00 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.98E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E000 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFDOORCP Operators Fail to Trip RCPs After Loss of Support Systems 0.02 1.610-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 OSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 e.O0E+00 305 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.000>00 ACAA5050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 8.000-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.100-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00+>00 PCF PLANT CAPACITY FACTOR 0.88 8.70E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIA SW Pump Ain maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 306 T10000SW Total Loss of Service Water 1 1.00E0>0 0.00E+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAAS0_50A FLAG - OFFBITE POWER MODE 50/00 ALT (CKT 751 TO BUS 12B. CKr 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-00 72 7.27E-05 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Ait Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG01BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00>E00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E000 AAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 307 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKr 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 025E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ANOff-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND Il 1 8.87E-01 DG1BNOTRUN FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.87E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > I HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E000 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCVC04603 Service Water Pump PSW01C Discharge Check Valve 4603 Fails To Close On Demand 5.84E-04 1 5.84E-04 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE IN AND ILLOGICAL CUTSETS 0 0.00E+00 308 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00

ACAASOS0A FLAG - OFFSITE POWER MODE 50/S0 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus IS 1.01E-06 1 8.8SE-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AN Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E-00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.002+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+000 309 TIOOOOSW Total Loss of Service Water 1 1.001+00 0.00>E00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LbOA) 1 1.SOE+00 ACAA50_50A FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AN Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.OOE+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.008+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-83 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 8 0.00E+00 310 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E800 ACAASO500A FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 I 8MB5E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ADOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 t.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.000+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG18NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZOORCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.8OE+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIB SW Pump B In maintenance 0.05 4.55E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 311 TIOOOOSW Total Loss of Service Water I 1.00E+00 0.00E+00 AAA*TRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-00 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Alt Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00>E00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.008+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 00.00E800 312 TI0000SW Total Loss of Service Water 1 1.008+00 0.001+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50.50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.8 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 t.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit alter failure of first 0.1 1.00E-01 313 TI0000SW Total Loss of Service Water 1 1.00E+00D0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.008+00 ACAAS0.50A FLAG - OFFSITE POWER MODE S50/SALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.8 5.00E-01 ACLOPRT751 Loss of Offsito Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 DGIANOTRUN FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-00 RCAZOOIRCP NO RCP SEAL COOLING FOR >1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOOAs 1 1.00E+00

$LO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.0012-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00+>00 ACHFDRCOFF Failure to recover second offsite power circuit alter failure of first 0.1 1.00E-01 314 TI0000SW Total Loss of Service Water 1 1.00E+00 0.008+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01

ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Sile Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E.00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.2112-02 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 DGDGFOO01B DIESEL GENERATOR KDG01 B FAILS TO RUN 1.41E-03 24 3.38E-02 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.002+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOOAS 1 1.002+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 315 TISOOOSW Total Loss of Service Water 1 1.002+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAASOSEA FLAG - OFFSITE POWER MODE 50/S0 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.28E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Tdp 2.10E-03 2.1OE-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG- Failure of AC Train B 1 1.00E+00 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGDGFOOIB DIESEL GENERATOR KDG0I B FAILS TO RUN 1.41E-03 24 3.38E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.002+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 AMAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 316 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E-00 ACAAM0L50A FLAG - OFFSITE POWER MODE SE/50ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 8.00E-01 ACLOPRTALL Loss of Ali Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E200 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG18NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGTMOOOOIB DIESEL GENERATOR KDGOIB UNAVAILABLE DUE TO TESTING OR MAINTENANCE 0.01 1.49E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZSO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 O.00E+00 317 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Iniflating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 6.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E200 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 DGCCOORUN DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE) 1.36E-03 1.36E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E200 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 AAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 318 TI0000SW Total Loss of Service Water 1 1.00E+00 0.002+00 AAAATRANSI TAG - Transient Iniating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA5OJS0A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.8 5.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E200 ACTRAINB TAG - Failure of AC Train B 1 1.00E200 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGCCO0ORUN DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE) 1 .36E-03 1.36E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.002+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.002+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWC)OXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.21E-04 1.0012-04 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 O.00E+00 319 TI0000SW Total Loss of Service Water I 1.00E+00 0.0012÷00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditiens (Seal LOCA) 1 1.00E200 ACAASOJOA FLAG - OFFSITE POWER MODE SE50/ ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Top 2.102-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Falluro of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGDGFOO01A DIESEL GENERATOR KDGOA FAILS TO RUN 1.41E-03 24 3.38E-02 DGDGF0001B DIESEL GENERATOR KDGOIB FAILS TO RUN 1.41E-03 24 3.38E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 11.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I1 1.002>00 1.O0E+DO SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+O0 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21 E-04 1.21E-04 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 320 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00ED00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E÷00 ACAASO_5OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AR Off-Site Power Following Reactor Trip 2.10E-03 2.1012-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+O0 ACTRAINB TAG - Fallur of AC Train B I 1.00E÷00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.83 8.76E-01

RCAZ051RCP NO RCP SEAL COOLING FOR ' 1 HOUR 1 1.00S+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00s+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I I.00E+n0 SWAASWPIBNR FLAG - Service Water Pump PSW0IB Is Not In Operation 0.42 4.21 E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP 0 TO RUN 0.02 2.47E-02 SWIMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 321 TIOOOOSW Total Loss of Servoce Water 1 1.0E+01 0.0OOE+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LOCA) I 1.00E+00 ACAASOOS0A FLAG - OFFSITE POWER MODE 50150 ALT (CK' 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of An Off-Site Power Following Reactor Trip 2.10f-o03 2.10E-03 ACTRAINA TAG - Fatlure of AC Train A 1 1.00E.00 ACTRAINS TAG - Failure of AC Train B I 1.O0E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND lB 1 9.87E-01 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR ' 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOGAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMSVPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPiC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 322 TI000OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Resulis in SI Conditions (Seal LOCA) 1 1.00E200 ACAASOf50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of At Off-Site Power Following Reactor Trip 2.10f-03 2.10f-03 ACTRAINA TAG - Failure of AC Train A 1 1.85E800 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG18NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 lOOfE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR ' 1 HOUR 1 1.00E+80 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.OOE+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.85E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.05E+00 323 TIOOOOSW Total Loss of Service Water 1 1.85E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.008E+8 ACAA5O 50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL. Loss of At Off-Site Power Following Reactor Trip 2.10f-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E-00 ACTRAINB TAG - Faolurn of AC Train B I 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.O0E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR ' 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.t052+85 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.85E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.80E+00 324 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.85E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Condotions (Seal LOCA) 1 1.85E+00 ACAA50SO0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.008f-01 ACLOPRTALL Loss of All Off-See Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.05E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCHFDOORCP Operators Fail to Trip RCPs After Loss of Support Systemn 0.02 1.61E-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 0 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.85E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 1 0.008+00 325 TI0000SW Total Loss of Service Water 1 1.00E700 0.01E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventuaey Results in SI Conditions (Seat LOCA) 1 1.008+00 ACAASO 5OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 1.81E-01 ACLOPRTALL Loss of An Off-Site Power Following Reactor Trip 2.10E-03 2.1.0E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Faelure ofAC Train B 1 1.00E-00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFDOORCP Operators Falt to Trip RCPs After Loss of Support Systems 0.02 1.61E-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E÷00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.0012.04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E÷00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 326 TI000OSW Total Loss of Service Water 1 1.00E+00 0.D0E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.0012+00 ACAASO 50A FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.0012-01 ACLOPRTALL Loss of An Off-Site Power Following Reactor Trip 2.10OE-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B I 1.00E+00 DG1ARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 0.03 3.00E-02 DGISNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT I 11.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR ' 1 HOUR 1 11.0012+00

SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.211-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS S 0.O0E+00 327 TIOOOSSW Total Loss of Service Water 1 1.00E+00 O.00E+00 AAAATRANSI TAG - Transient Initiating Event Which ESentually Results in SI Conditions (Seal LOCA) I 1.00E+00 ACAAS0SOA FLAG - OFFSITE POWER MODE 5/50 ALT (CK"T751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of At Off-Site Power Following Reactor Trip 2.101-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 0.03 3.00E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00+E00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E÷00 328 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSt TAG - Transient Initiating Event Which Evenotualy Results In SI Conditions (Seal LOCA) 1 1.008+00 ACAA5050N FLAG - OFFSITE POWER MODE 5/SO NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 128) 0.02 1.70E-02 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.008-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - 00 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG -0 08 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.80 8.76E-01 RCAZO0IRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.008+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00+O00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 O.00E+00 329 T10000SW Total Loss of Service Water 1 1.00E+00 0.0OE+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAASO_50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 OGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.768E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > I HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOAs 1 1.00+E00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.0OE+00 SWCCIPUMPSR Common Cause Falure Of Service Water Pumps To Run 1.211-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 330 TI0000SW Total Loss of Service Water 1 1 008+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACAA50_50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AS Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG- Falure of AC Train B 1 1.008+00 DGIANOTRUN FLAG -DG 1A IS NOT RUNNING AND TIEDTO BUSES 14AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR + 1 HOUR 1 1.00E+00 SEALLOCA TAG -TRANSIENT INDUCED SEAL LOCAs 1 1.008+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00+E00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.008E00 331 T10000SW Total Loss of Seruice Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 1 0.58E-03 ACB2FIBS18 Local Fault o0 480 VAC Bus 18 1.01E-06 1 8.858-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.008+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED 0.12 1.23E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAZINTAKE Assumplion that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (32/2052 his) 0.02 1.66E-02 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 332 TI000OSW Total Loss of Service Water 1 1.00E+00 O.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eveotualy Results in SI Conditions (Seat LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.851-03 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-0O ACTRAINA TAG - Failur of AC Train A 1 1.00E+00 ACTRAINB TAG - Faulure of AC Train B 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP 1.00E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.008+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 333 T10000SW Total Loss of Service Water 1 1.008+00 O.008E00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.018-06 1 6.85E-03 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01 E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03

NOSBO TAG - NO STATION BLACKOUT 1 1.OcE+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR >1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.OOE+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 334 TI000OSW Total Loss of Service Water 1 I.00Ev00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In St Conditions (Seal LOCA) 1 1.00E+00 AC82FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLYLOAD CHARGING PUMP 1.00E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > I HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Failure Of Service Vlater Pumps To Start 1.14E-04 1.14E-04 335 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.05E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-O1 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLYLOAD CHARGING PUMP 1.00E-03 1.001-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+O0 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3-28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 338 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E200 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01

.CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLYLOAD CHARGING PUMP 1.000-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+O0 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.000+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 337 TI0000SW Total Loss of Service Water I 1.00E+00 0.000+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLYLOAD CHARGING PUMP 1.00E-03 1.000-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.OOE-00 SWrMPUMP1A SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 1.000+00 0.00E+00 1 1.00E+00 338 T10000SW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.805-03 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING D.58 5.77E-01 FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-011 CVAACHPMPC CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE D.08 8.21E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE 0.09 8-6OE-02 0.0lE 3 3.13E5-03 CVTMCHPMPC TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE 1.04 3.85E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-011 RCAZO01RCP NO RCP SEAL COOLING FOR >1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 11.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 11.00E+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 339 TI0000SW Total Loss of Seivice Waler 1 1.00E+00 0.00E+00 AAMATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.000+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVCCMPFABC COMMON CAUSE FAILURE OF THE CHARGING PUMPS TO RUN 1.36E-05 1.36E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.(X)E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.113E-02 SWTiMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 340 T10000SW Total Loss of Service Water 1 1,00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seat LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 CVMMRCPAFP NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL 4.88E-05 4.88E-05 NOSBO TAG - NO STATION BLACKOUT I 11.00E+00 POF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 11.0012+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 341 TIOO0SW Total Loss of Service Water 1 1.0012+00 0.00E+O0 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 CVMMRCPALP NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER 5.34E-05 5.34E-06 NOSBO TAG - NO STATION BLACKOUT I 11.00E+00 PCF PLANT CAPACITY FACTOR 0,88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR

  • 1 HOUR I 11.00E+00

SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 S'WTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 342 TISOOOSW Total Loss of Service Water 1 1.00E+00 O.001E00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIES17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPBFP NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER 4.88E-05 4.88E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ001RCP NO RCP SEAL COOLING FOR - 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E-00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1A SW Pump A inmaintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 343 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventualy Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPBLP SEAL LEAKOFF PATH FROM RCP B OBSTRUCTED 5.34E-05 5.34E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1,00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+80 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C inmaintenance 0.04 3.56E-02 344 TI0000SW Total Loss of Service Water 1 1.008+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.008+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ00tRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOOAs 1 1.008+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 345 TI0COOSW Total Loss of Service Water 1 1.00E+00 0,008E00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFDO0RCP Operators Fail to Tdp RCPs After Loss of Support Systems 0.02 1.61E-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.008+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1A SW Pump Ain maintenance 0.03 3.13E-02 SWTFMPUMPIC SWNPump C in maintenance 0.04 3.56E-02 346 TIO0OOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.851-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVPPJCVCOM Common CVCS Piping Rupture 1.98E-00 24 4.75E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.008+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 347 TIOGO0SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP 1.00E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01RCP NO RCP SEAL COOLING FOR ' 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 348 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 349 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOOA) 1 1.00E+00 ACB2FIBS18 Local Fault o0 480 VAC Bus 18 1.01E-00 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP 1.008-03 1.008-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR ' 1 HOUR 1 1.008+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOOA SEQUENCE 1 1.008+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 350 TI0000SW Total Loss of Service Water 1 1.008+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBSS8 Local Fault on 480 VAC Bus 18 1.011E-06 1 8.80E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHIPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01

CVHFDPMPST OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP 1.0OE-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01 RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWMM0SWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 351 TISOOOOW Total Loss of Service Water I 1.008+00 0.00E+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLYLOAD CHARGING PUMP 1.00E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.O0E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.OlE+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALLSMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1 B SW Pump B in maintenance 0.05 4.5SE-02 SWTMPUMP1 D SW Pump D in maintenance 7.15E-03 7.15E-03 352 T10000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-05 1 8.85E-03 ACTRAINA TAG - Faiure of AC Train A 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE 0.09 8.60E-02 CVTMCHPMPC TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE 0.04 3.85E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 353 T10000SW Total Loss of Servoce Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPAFP NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL 4.88E-05 4.88E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 354 TIOOOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E800 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E÷00 CVMMRCPALP NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER 5.34E-05 5.34E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 355 T100OSW Total Loss of Service Water 1 1.008+00 0.0OE+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conddlons (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPBFP NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER 4.88E-O05 4.88E-O5 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 356 710000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPBLP SEAL LEAKOFF PATH FROM RCP B OBSTRUCTED 5.34E-O5 5.34E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.001+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00+E00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 357 T10000SW Total Loss of Service Water 1 1.00E+00 0.001+00 AAAATRANSI TAG - Transient Initiating Event Which Eventuatly Results in SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 I 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.501-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZOIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.008>00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 358 TIO7O1SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 CVPPJCVCOM Common CVCS Piping Rupture 1.98E-06 24 4.75E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO0IRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPiD SW Pump D in maintenance 7.15E-03 7.15E-03 359 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditiens (Seal LOCA) 1 1.00E+00

CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 S.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVCCMPAABC COMMON CAUSE FAILURE OF CHARGING PUMPS TO START 5.78E-05 5.78E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.001+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 360 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVCCMPAABC COMMON CAUSE FAILURE OF CHARGING PUMPS TO START 5.78E-OS 5.78E-05 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.001+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR) 1.00E-04 1.00E-04 361 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-C1 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAILTO MANUALLY LOAD CHARGING PUMP 1.00E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Servine Water Pumps To Run 1.21E-04 1.21E-04 362 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP S RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG- CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLYLOAD CHARGING PUMP 1.00E-03 1.00E-C3 NOSSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-C1 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR) 1.00E-04 1.00E-04 363 T10000SW Total Loss of Service Water I 1.00E+00 0.OOE+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-C1 CVHFDPMPST OPERATORS FAIL TO MANUALLYLOAD CHARGING PUMP 1.00E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFD00RCP Operators Fail to Trip RCPs After Loss of Support Systems 0.02 1.61E-02 SEALLOIdA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 364 TI0000SW Total Loss of Service Waler 1 1.005+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVHFDPMPST OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP 1.00E-03 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCHFD0ORCP Operatom Fail to Trip RCPs After Loss of Support Systems 0.02 1.81E-02 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E500 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 365 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-C1 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-C1 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVMMPCH1CA CHARGING PUMP PCH01C FAILS TO START 1.04E-03 1.04E-03 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE 0.09 8.80E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.001200 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZ0O1RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.005+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 366 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVMMPCH1CA CHARGING PUMP PCH01C FAILS TO START 1.04E5-3 1.04E-03 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP S UNAVAILABLE 0.09 8.60E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.001+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZODIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.005200 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 367 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.001+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-C1 CVAACHPMPB FLAG - CHARGING PUMP S RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVMMPCH1CF CHARGING PUMP PCHOIC FAILS TO RUN 1.31E-03 1.31E-03 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE 0.09 8.60E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E-00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E-00 SW1CCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 368 TIOOOOSW Total Losw of Service Water 1 1.00E+00 0.OOE+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results InSI Conditions (Seal LOCA) 1 1.00E+00

CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP S RUNNING 0.58 577E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVMMPCH1CF CHARGING PUMP PCH01C FAILS TO RUN 1.31E-03 1.31E-03 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE 0.09 8.60E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCxXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 389 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 CVAACHPMPB FLAG - CHARGING PUMP B RUNNING 0.58 6.77E-01 CVAACHPMPC FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21 E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP S UNAVAILABLE 0.09 8.60E-02 CVTMCHPMPC TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE 0.04 3.85E-02 NOSSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 370 TIOOOOSW Total Loss of Servce Water I 1.00E+00 0.00E+00 AAAATRANSI tS Conditions (Seal LOCA)

TAG - Transient Initialing Event Which Eventually Results in I 1.00E+00 CVAACHPMPA FLAG - CHARGING PUMP A RUNNING 0.08 5.77E-01 CVAACHPMPB FLAG- CHARGING PUMP B RUNNING 0.58 5.77E-01 CVAACHPMPC FLAG- CHARGING PUMP C RUNNING 0.58 5.77E-01 CVTMCHPMPA TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE 0.08 8.21E-02 CVTMCHPMPB TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE 0.08 8.60E-02 CVTMCHPMPC TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE 0.04 3.85E-02 NOSSO TAG - NO STATION BLACKOUT I 1.00E-00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZOOIRCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs I 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 371 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001 RCP NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAASWP1 BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG- Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.00 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 372 110000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 t.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 I.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+O0 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWPPJIHDRB SERVICE WATER HEADER "5" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWIMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.03 4.55E-02 SWIMPUMPIC SW Pump C In maintenance 0.04 3.58E-02 373 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZO01RCP NO RCP SEAL COOLING FOR> 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAASWP1ER FLAG - Service Water Pump PSWO1 B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 374 TI0000SW Total Loss of Service Water 1 1.00E+00 0.002+00 AAAATRANSI TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZ001RCP NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SWAASWPIBR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.478-02 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 375 TIO0OOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) I 1.00E+00 CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZOO1RCP NO RCP SEAL COOLING FOR > 1 HOUR I 1.00E+00 SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.0012+00 SSLO TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 SWAASWPIDR FLAG - Service Water Pump PSW1DD Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4M84E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 376 TIOO0SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA0O100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 125) 0.02 1.5012-02 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 A*LOPRT7$1 Loss of Offsile Circuit 751 Following Reactor Trip 2.12E-03 2.112E-03 ACTRAINA TAG - Failure of AC Train A 1 1.0012+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E÷00

DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGI BNOTRUN FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 1SAND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E.00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Case Failure Of Service Water Pumps To Run 1.211-04 1.21E-04 SWTOOG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.OOE+00 ACHFORCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00S-01 377 TI1O0OSW Total Loss of Service Water 1 1.00OE+00 0.00E00 ACAAOIOOX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12AAND 128) 0.02 1.50E-02 ACAZDLOSP1 Failure to Restore Offsite Power Wilthin I Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG;B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

$60 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to D1 (cooling) 1 1.00E200 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.000E00 ACHFDRCOFF Failure to recover second offsite power circuit afterfa/lure of first 0.1 1.00E-01 378 TI0000SW Total Loss of Service Water 1 1.00E-00 0.00E+00 ACAA0.100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128) 0.02 1.50E-02 ACAZDLOSPI Failure to Restore Offskie Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 8.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.000+00 DGIANOTRUN FLAG - D0 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - 0DG IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to D0 (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS O 0.00E+00 379 TIOOO0SW Total Loss of Service Water 1 1.00E+00 0.000000 ACAAO_100X FLAG - OFFSrTE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.50E-02 ACAZDLOSP1 Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.000-01 ACLOPRTALL Loss of ANOff-Site Power Folklwing Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG- Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - D 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG -0O B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 8.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.761-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to D0 (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 380 T10000SW Total Loss of Service Water 1 1.00E+00 0.000+00 ACAAO..100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128) 0.02 1.50E-02 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.011E-06 1 8-85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offs/te Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.000+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.87E-01 DG1 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.58E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsita power circuit after failure of first 0.1 1.00E-01 381 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA0_b1OX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.50E-02 ACB2FIBS17 Local Faust on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.001-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.100-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to D0 (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.000200 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00+E00 382 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAO.100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.50E-02 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offlste Circuit 751 Following ReactorTop 2.12E-03 2.12E-03 ACTRAINA TAG - Failure ofAC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 8.97E-01 DGIBNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 BED TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to D0 (cooling) 1 1.00E+00 WAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offs/Ie power circuit after failure of first 0.1 1.00E-01 383 TI000OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA0_100OX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 138 AND 12B) 0.02 1.50E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Faiure of AC Train A 1 1.00E+00 ACTRAINB TAG - Faiurm of AC Train B 1 1.00E+00 AFAZFAIL)OC Non-Elec Fa/lure of al MDAFW pumps (independeont of AF300) 0.1 1.00E-01 DG1ANOTRUN FLAG - D 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.000+00

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

$80 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 WCCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.0gE-04 1.OOE-04 SWTODG TAG - SW Lost to D0 (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 g.00E+00 ACHFDRCOFF Failure to recover second offshe power circuit after failure of first 0.1 1.00E-01 384 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA.L10OX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.50E-02 ACLOPNOS12 CORRECTION FACTOR FOR NO $S CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsute Circuit 751 Following Reactor Top 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGlANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG -0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Fallur Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00+E00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTBETS 0 8.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 385 TI000OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAO.1 OX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12AAND 12B) 0.02 1.50E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loon of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00+E00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 WAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.008E00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 386 TI00O0SW Total Loss of Service Water 1 1.00E+00 0.008+00 ACAAO100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12AAND 12B) 0.02 1.50E-02 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Ag Off-Site Power Following Reactor Trip 2.18E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps Undependentof AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSSO TAG - NO STATION BLACKOUT 1 1.00+E00 PCF PLANT CAPACITY FACTOR 0.88 8.768E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWITODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00+E00 387 TIOOOOSW Total Loon of Service Water 1 1.00E+00 0.00E+00 ACAA0_10NX FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.50E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AlHOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps independent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.008-04 SWTODG TAG - SW Lost to 00 (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 388 TI000CSW Total Loss of Service Water I 1.00E+00 8.00E+00 ACAAO.. OX FLAG - OFFSITE POWER MODE 8/100 (CKT 751 SUPPLYING BUSES 12A AND 128) 0.02 1.50E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of An Off-She Power Following Reactor Trip 2.10E-03 2.110E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.80E+80 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E.01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 121E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 0 5.00-E+0 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 389 TI1000SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA0_100X FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128) 0.02 1.80E.02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E.01 ACLOPRTALL Loss of Alt Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINS TAG - Failure of AC Train B I 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.0012+00 PCF PLANT CAPACITY FACTOR 0.88 8t.76E-01 SWCOCSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODOG TAG - SW Lost to 0G (cooling) I 1.00ED00 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 AAAA FACTOR TO ELIMINATE WV AND ILLOGICAL CUTSETS 0 0.00E+00 390 TIO0O0SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA100_0X FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACAZDLOSPI Failure to Reotow Offsite Power Within 1 Hour 0.3a 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E.-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00)

AFAXITDAFW TAG - TDAFW Pump operates successfully I 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG -0D B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 58O TAG - STATION BLACKOUT SEQUENCE I 11.00E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E.02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E.02 SWTODG TAG - SW Lost to DG (cooling) 1 11.00E+00 ACHFDRCOFF Fallure to recover second offsite power circuit after taioure of first 0.1 1.00E-011 391 TIO0OOSW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAAI00OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZDLOSPI Falure to Restore Offsite Power Within 1 Hour 0.38 3.811E-01

ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTI767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DOIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.001+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.06E-02 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+O0 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offitne power circuit after failure of first 0.1 1.00E-01 392 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAI00 0X FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACAZDLOSPI Failure to Restore Offste Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AN Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 S80 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.068-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 393 T10000SW Total Loss of Seicae Water 1 1.00E+00 0.00E+00 ACAA11000X FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZOLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SB6 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C In maintenance 0.04 3.50E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00+E00 394 T10000SW Total Loss of Service Water 1 1.00E+00 0.008+00 ACAAI 00-OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.446-01 ACAZDLOSPI Failure to Restore Offste Power Within 1 Hour 0.38 3.81E-01 ACB2FIB181 Local Fault on 480 VAC Bus 18 1.01 E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.0 5.00E-01 ACLOPR1T77 Loss of Offslte Circuit 767 Following Reactor Trip 2.12E-03 2.128-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E÷00 ACTRAINB TAG - Failure of AC Train B 1 1.001+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.151-03 7.15E-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 ACHFORCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.008-01 395 TI0000SW Total Loss of Service Water 1 1.00E800 0.00E+00 ACAAIO0_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-i1 ACLOPRT7B7 Loss of Offsite Circuit 767 Following Reactor Tfip 2.12E-03 2.128-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMPIB SW Pump Bin maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.151-03 SWTODG TAG - SW Lost to DO (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsfte power circuit after failure of first 0.1 1.00E-01 3986TI000SW Total Loss of Service Water 1 1.008E00 0.00E+00 ACAA10CLOX FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.446-01 ACAZDLOSPI Failure to Restore Ofisite Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS1O Local Fault on 480 VAC Bus 18 1.01 E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.8 9.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Top 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.008+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGI8NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 S80 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMP1 B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.156-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 397 TI0000SW Total Loss of Service Water 1 1.008E00 0.00E+00 ACAA1 00_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.446-01 ACAZOLOSPI Failure to Restore Offsoe Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 9.00E-01 ACLOPRTALL Loss of Alt Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.008+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.972-01 DG18NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 880 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMP1B SW Pump B in maitenanoce 0.08 4.80E-02 SWTMPUMP1D SW Pump D in maiotenance 7.1tE-03 7.15E-03

SWTODG TAG - SW Lost to DG (cooling) 1 1.001+00 AAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 398 T10000SW Total Loss of Service Water 1 1.006+00 0.00E+00 ACAAI00_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES M2A AND 12B) 0.14 144E-01 ACAZDLOSP1 Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.0 5.00E-01 ACLOPRT787 Loss of Offate Circuit 767 Following Reactor Trip 2.12E-03 2.121-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.OE+÷00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 6.97E-01 DG1BNOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Servce Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsfte power circuit after failure of first 0.1 1.00E-01 399 TI0000SW Total Loss of Service Water 1 1.00E+00 0.002+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACAZDLOSP1 Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.002-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.121-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGlANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG 6 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost Io DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second atnsite power circuit after flaure of first 0.1 1.00E-01 400 TI0000SW Total Loss of Service Water 1 1.008E00 0.00E+00 ACAA100OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPUES BUSES 12A AND 128) 0.14 1.44E-01 ACAZDLOSPI Failure to Restore Offsite Power Within I Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.002E00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 0.97E-01 DGIBNOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 401 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100..OX FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACAZDLOSP1 Failure to Restore Offsite PowerWfithin 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.002+00 ACTRAINB TAG - Failure of AC Train B 1 1.002+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND lB 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.008+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR) 1.00E-04 1.008-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.001200 402 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100OX FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsie Circuit 767 Following Reactor Trip 2.122-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.008+00 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps lindependent of AF300) 0.1 1.00E-01 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSEO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.002+00 SWrMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.50E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS O 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after faltre of first 0.1 1.00E-01 403 T10000SW Total Loss of Service Water 1 1.00+E00 0.00E+00 ACAA100 0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS17 Local Fauit on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.002-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 D*IANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND l8 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Fallure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DOG(cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.001200 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after fauure of first 0.1 1.00E-01 404 T10000SW Total Loss of Service Water 1 11.0012+00 0.0012+00 ACAA1 00_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FI5S17 Local Fault on 480 VAC Bus 17 1.01E-00 1 8.85E-03 ACLOPNOSt2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPR1767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.972-01 DGIBNOTRUN FLAG -0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.28E-03 SWTMPUMPtC SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to D1 (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT I 11.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E÷00

ACHFDRCOFF Failurm to recoversecond offsie power circuit after faaiure of first 0.1 11.0E-01 405 TI0000*W Total Loss of Service Water 1 1.00E+00 0.OOE+00 ACAA100OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIES1 7 Local Fault on 480 VAC Bus 17 1.01E-o06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsote Circuit 767 Following Reactor Tdp 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E-00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.07E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+80 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 406 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00Eu00 ACAA1000X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsto Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.001+00 ACTRAINB TAG - Falure of AC Train B 1 1.00E800 DGIANOTRUN FLAG - DG lA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.87E-01 DGISNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E200 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AmA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsie power circuit after failure of first 0.1 1.001-01 407 TIOO0OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100JX FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 AC82FIBS17 Locel Fauot on 480 VAC Bus 17 1.01E-06 1 8.85F-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Alt Off-She Power Following Reactor Trip 2.101-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+O0 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Etec Faluret of all MDAFW pumps independent of AF300) 0.1 1.00E-01 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DOGIBNOTRUN FLAG DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.971-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00Ee00 408 TI000OSW Total Loss of Service Water I 1.00E+00 8.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.008-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINE TAG - Failre of AC Train B 1 1.00E+00 D*lANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - 0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 409 TIOOOOSW Total Loss of Service Water 1 1.00E+00 O.00+E00 ACAA1O0OX FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.018-00 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of At Off-She Power Following Reactor Trip 2.108-03 2.1OE-03 ACTRAINA TAG - Failure atACGTrain A 1 1,00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DOGIA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.008E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3-28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+000 410 TI0000SW Total Loss of Service Water 1 1.008+00 0.00E+00 ACAA`100JX FLAG - OFFSITE POWER MODE 10010 (CKT 787 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Foltoiag Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.80 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.08E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AmAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 411 TI000OSW Total Loss of Service Water 1 1.00E+00 0.008+00 ACAA1 00_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 AC82FIBS17 Local Fault on 480 VAC Bus 17 1.011E-08 1 8.86E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP .05 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DOGIA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 POF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWrMPUMPIA SW Pump A inmaintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DO (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00

AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 412 TISOOOSW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA100O0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-a1 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offstte Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGI BNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Case Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.001+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 413 TIOOOOSW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA100J0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 125) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-O1 ACLOPRT767 Loss of OffsIte Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.8 8 .76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 AAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second oflsite powercircuit after faiure of first 0.1 1.001-01 414 TIOOOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAM100OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01 E-06 1 8.85E-03 ACLOPNOS12 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 0.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recoversecoaid offsote power circuit after failure of first 0.1 1.00E-01 415 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Ait Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 416 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 10 1.01E-06 1 8.85E-03 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AnlOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.00 4.55E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AMMA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 417 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACB2FIBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.0 5.00E-01 ACLOPRTALL Loss of ADOff-Site Power Following Reactor Trip 2.108-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train 8 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.115-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.002+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAMM FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 418 TI0000SW Total Loss of Service Water 1 1.008+00 0.00+E00 ACAA10OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A I 1.OOE+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps findependent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 .97E8-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBC TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Canoe Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01

419 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100O0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.8 5.00E-01 ACLOPRT767 Loss of Offs/te Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure ofAC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.00E-01 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR) 1.006-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsie power circuit after failure of first 0.1 1.002-01 420 T10000SW Total Loss of Service Water 1 1.00E800 0.00E+00 ACAA100 0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.218-04 8WTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.008+00 ACHFDRCOFF Failure to recover second offshe power circuit after failure of first 0.1 1.00E-01 421 T10000SW Total Loss of Service Water 1 1.00E800 0.00E+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.001-01 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 16 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.006-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offste power circuit after failure of first 0.1 1.002-01 422 T10000SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA10_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.008+00 AFAZFAILXX Non-Elec Failure of at MDAFW pumps (Independent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1IBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.216-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 423 TI0000SW Total Loss of Service Water 1 1.00E+00 0.008+00 ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0. 5-00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.008+00 AFAZFAILXX Non-Elec Failure ofall MDAFW pumps (independent of AF300) 0.1 1.00E801 DG1ANOTRUN FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E+D0 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.OOE+00 424 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100_0X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ANOff-Site Power Following Reactor Trip 2.101-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DO (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 425 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA100 0X FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128) 0.14 1.44E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.008-01 ACLOPRTALL Loss of Ali Off-Site Power Following ReactorTrip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train 8 1 1.008+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 98.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DOG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 426 T10000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACAAS0O50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 126, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAASO_50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSPI Failure to Restore Offsite Power Whhin 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offshie Circuit 751 Following Reactor Trip 2.128-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.008+00 DGIANOTRUN FLAG - DG tA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01

DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.971-01 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 427 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.001+00 ACAASO50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAASOSON FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSPI Failure to Restore Olfste Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following ReactorTrip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Faulure of AC Train B 1 1.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00OE00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 428 TI0OOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAASO50A. FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAASO_50N FLAG - OFFSITE POWER MODE 50/SONORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSPI Failure to Restore Offsie Power Within I Hour 0.38 3.818-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.6 5.00E-01 ACLOPRT751 Loss of Offsfte Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 8.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E800 SWCCIPUMPSR Common Cause Fa/ure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 O.00E+00 ACHFDRCOFF Failure to recover second offsIhe power circuit after failure of first 0.1 1.008-01 429 T10000SW Total Loss of Service Water 1 1.00E+00 0.001E00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAA50 50N FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128) 0.02 1.70E-02 ACAZDLOSP1 Failure to Restore Offsite Power Wthin 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP .05 5.008-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SB TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.008-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 430 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAS_-50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 707 TO BUS 12A) 0.83 8.25E-01 ACAASOSON FLAG - OFFOITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSPI Failure to Restore Offsite PowerWtlhin I Hour 0.38 3.818-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT787 Loss of Offite Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG18NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE IV AND ILLOGICAL CUTSETS 0 0.OOE+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 431 TI000SOW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAASO50SOA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACAAS0 5ON FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B) 0.02 1.708-02 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Off/ste Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAX1TDAFW TAG - TDAFW Pump operates successfully 1 1.001+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.008-04 1.00E-04 SWTODG TAG - SW Lost to DO (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 432 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAS_50OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.258-01 ACAASO-50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128) 0.02 1.70E-02 ACAZDLOSPI Failure to Restore ODsire Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsite Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG0 81 NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E+00 SWCCIPUMPSR Common Cause Fa/lure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 433 T10000SW Total Loss of Service Water I 1.00E+00 0.008+00 ACAAS0.5A FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAA50.5ON FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128) 0.02 1.708-02 ACAZDLOSPI Fa/lure to Restore Offsite Power Within I Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01

ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E-00 ACTRAINB TAG - Failure of AC Train B 1 1.OOE+00 DGIANOTRUN FLAG -DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BENOTRUN FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.008-O4 1.00E-04 SWTODG TAG - SW Lost to 00 (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after falurm offirst 0.1 1.008-01 434 TIODOOSW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA50L.S0A FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAAS0_5ON FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 787 TO BUS 128) 0.02 1.70E-02 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsie Crcuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-O1 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.008+00 ACHFDRCOFF Failure to recover second of/slte power circuit after failure of first 0.1 1.0OE-01 435 TI000OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50SQOA FLAG - OFFSITE POWER MODE 50/SO ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAASOS0N FLAG - OFFSITE POWER MODE 50/SO NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-00 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offske Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 i.0OECO0 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.978-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Faiure to recover second onslte power circuit after failure of first 0.1 1.00E-01 436 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAS30-OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAA50-50N FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKOT787 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offshe Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00+E00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG -0 0; IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - O B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.OOE+00 ACHFDRCOFF Failure to recover second ofnsthe power circult after fa/lure of find 0.1 1.00E-01 437 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50O50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAASOJ50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsie Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.008+00 AFAZFAILXX Non-Elec Failure of al MDAFW pumps (independent of AF300) 0.1 1.001-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E801 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to 0G (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.008+00 ACHFDRCOFF Failure to recover second of/tsite power circuit after failure of first 0.1 1.00E-01 438 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA5050A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.53 8.25E-01 ACAA50._50N FLAG - OFFSITE POWER MODE 50/SO NORMAL (CKT 751 TO BUS 12A, CK'T 767 TO BUS 128) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsie Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - 0G B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.978-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.008E00 TRANSX TAG - TRANSIENT EVENT 1 1.008E00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsle power circuit after failure of first 0.1 1.00E-01 439 T10000SW Total Loss of Service Water 1 1.00E+00 0.008E00 ACAASL-50A FLAG - OFFSITE POWER MODE 50/50 ALT (CK'T 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAAS0q50N FLAG - OFFSITE POWER MODE 50/SO NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128) 0.02 1.70E-02 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.001-01 ACLOPRT751 Loss of Offs/le Circait751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG - 0G0 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E800 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.OO12+00 ACHFDRCOFF Failure to recover second of/tie power circuit after failure of first 0.1 1.00E-01

440 TIOOOSW Total Loss of Service Water 1 1.00E+00 0.002+00 ACAAO_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 122, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAAOO N50 FLAG - OFFPITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 122) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT787 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 l.005+00 AFAZFAILXO Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.002+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to 0G (coolng) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E200 ACHFDRCOFF Falure to recover second offshie power circuit after failure of first 0.1 1.00E-01 441 T10000SW Total Loss of Service Water 1 1.00E200 O.002E00 ACAA0_J50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAA5S50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.002-01 ACLOPRT787 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAIL.XX Non-Elec Failure ofall MDAFW pumps (independeot of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG IA IS NOT RUNNING ANDTIED TO BUSES 14 AND 18 1 9.972-01 DGIBNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 10 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to D1 (cooling) 1 1.00E+00 AAAA FACTOR TO EUMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Falour to recover second offshe power circuit after fanure of first 0.1 1.00E-01 "442 110000SW Total Loss of Service Water 1 1.00+E00 0.00E+00 ACAAS0_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 787 TO BUS 12A) 0.83 020E201 ACAA50_50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 787 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT767 Loss of Offsihe Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 0.97E-01 DG1BNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.002+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsfte power circuit after failure of irat 0.1 1.00E-01 443 71000OSW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA50 50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAAS0OJON FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKr 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 S.00E-01 ACLOPRT767 Loss of Offsee Circuit 787 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.002+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to D0 (cooling) 1 1.002+00 TRANSX TAG - TRANSIENT EVENT 111.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 444 T10000SW Total Loss of Service Water 1 1.00E÷00 0.001+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPi Failure to Restore Offatte Power Within 1 Hour 0.38 3.81E-01 AC82FIBS17 Local Fault on 480 VAC Bus 17 1.012-06 1 8.85E-03 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 8.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Top 2.10E-03 2.110E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E÷00 DG1ANOTRUN FLAG - DI IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - D B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.0012+00 SWTODG TAG - SW Lost to D0 (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 "440TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 0.83 8.25E-01 ACAA5O0.50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128. CKT 767 TO BUS 12A)

ACAZDLOSP1 Failure to Restore Offsite Power Within I Hour 0.38 3.8112-01 ACB2FIBS17 Local Fauft on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 6.00E-01 ACLOPRTALL Loss of At Off-Shie Power Following Reactor Trip 2.10E=-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.0012+00 ACTRAINB TAG - Falure of AC Train B I 1.00E-00 AFAXITDAFW TAG - TDAFW Pump operates successfully I 1.00E+00 DGIANOTRUN FLAG - D0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 80 TAG - STATION BLACKOUT SEQUENCE I 11.00E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-0T2 SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 448 T10000SW Total Loss of Service Water I 1.00E+00 0.0012+00 ACAA50-50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACAZOLOSPI Failure to Restore Offshe Power VWthin1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.10E-03 2.110E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Faollre of AC Train B 1 1.00E÷00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.9712-011 DGIBNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.9712-011 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 S2O TAG - STATION BLACKOUT SEQUENCE 1 1.O0E+00 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E÷00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E÷00

447 T100O0SW Total Loss of Service Water 1 1.00E+00 0.OOE+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Oflsite Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 101E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-O1 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Falluo of AC Train A I 1.08E+00 ACTRAINB TAG - Failure of AC Train B 1 1.005+00 DGIANOTRUN FLAG - DGlIA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1lBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 "448TIDOOOSW Total Loss of Service Water 1 1.00E+00 0.005+00 ACAAS0_5OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSP1 Failure to Restore Offslte Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-OS 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 505E-01 ACLOPRTALL Loss of Alt Off-Sie Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.05E+00 ACTRAINB TAG - Fauture of AC Train B 1 1.80E+00 DGIANOTRUN FLAG - DO;IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.80E+80 PCF PLANT CAPACITY FACTOR 0088 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E-*0 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTODG TAG - SW Lost to DG (cooling) I 1.OOE00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.05E+00 449 TIOOOSW Total Loss of Service Water 1 1.00E+00 0.80E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsieo Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E5O0 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.05E+00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E500 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 450 T10000SW Total Loss of Service Water 1 1.001O20 0.05E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.26E-01 ACAZDLOSPI Failure to Restore Offsite Power Within I Hour 0.38 3.81E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL. Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Faulure of AC Train S 1 1.80E+80 DGIANOTRUN FLAG - D0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 8.87E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+50 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

$5O TAG - STATION BLACKOUT SEQUENCE 1 1.05E+00 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 A*AA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.80E+00 451 T10000SW Total Loss of Service Water 1 1.80E+00 0.00E+00 ACAASO50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS I1A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offsite Power Within 1 Hour 0.38 3.81t-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01 E-06 1 8.85E-03 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.05E-01 ACLOPRTALL Loss of AS Off-Site Power Following Reactor Trip 2.105-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Faoure of AC Train B 1 1.05E+00 AFAXITDAFW TAG - TDAFW Pump operates successfully 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D In maintenance 7.15E-03 7.1155-03 SWTODG TAG - SW Lost to 00 (cooling) I 1.00E+00 452 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.00E÷00 ACAASO5_0A FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSP1 Failure to Restore Offsle Power Within I Hour 0.38 3.81E-01 ACB2FIBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-She Power Following Reactor Trip 2.110E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Fauure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGISNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 E 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCPUMPSS Common Cause Fatlure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling)

AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 1.805+00 453 T10000SW Total Loss of Service Water I 11.00E+00 0,00E+00 ACAASOSSA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSP1 Failure to Restore Offsite Power Within 1 Hour 0.38 3.81E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.8515-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 11 0.5 9.975-01 5.00E-011 1.005+80 ACLOPRTALL Loss of Ali Off-Site Power Following Reactor Trip 2.,t0E-03 2.110E-03 ACTRAINA TAG - Failure of AC Train A I 1,00E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 DGIANOTRUN FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DG1 BNOTRUN FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E+00 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02

SWTODG TAG - SW Lost to DG (cooling) 1 1.008E00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 454 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 00150ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 3.25E-01 ACAZDLOSPI Failure to Restore Offshe PowerWfthirt I Hour 0.38 3.811-01 ACB2FIBS1S Local Fault on 480 VAC Bus 18 1.01E-06 1 0.865-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG. DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.10E-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.008+00 AAAA FACTOR TO EUMINATE UV AND ILLOGICAL CUTSETS 0 0.00E-00 455 TI000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA5O0LOA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSP1 Failure to Restore Offsfte Power Within 1 Hoar 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of At Off-Site Power Followiog Reactor Trip 2.108-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 1DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Camse Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO EUMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 456 T10000SW Total Loss of Service Water 1 1.00E+00 0.001+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 777 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restow Offslte Power Within 1 Hour 0.38 3.61E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTAL. Loss of All Off-Shte Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.978-01 Dl 1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to 00 (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 457 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA5_S50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 126, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACAZDLOSPI Failure to Restore Offshe Power Within 1 Hour 0.38 3.91E-01 ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ADOff-Ste Power Following ReactorTrip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG- Failure of AC Train B 1 1.00E+00 DGIARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 15 0.03 3.00E-02 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.008+00 458 TIOO70SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA5OL50A FLAG - OFFSITE POWER MODE 50/50 ALT (ClKT751 TO BUS 12B, CKr 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 0.85E-03 ACB2FIBS18 Local Faulton 480 VAC Bus 18 1.01E-06 I 9.85E-03 ACLOPNOS12 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.9 0.00E-01 ACLOPRTALL Loss of Al Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED 0.12 1.23E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (32/2052 hOs) 0.02 1.66E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E.00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.08E+00 450 T10000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACB2FTBS18 Local Fault on 480 VAC Bus 19 1.01E-06 72 7.27E-05 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.006-01 ACLOPRTALL Loss of AS Off-She Power Followeing Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG- Failureof AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG18NOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTODG TAG - SW Lost to DG (cooling) 1 1.0082-00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 460 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAS0_.0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offslte Ciruist 751 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINB TAG - Failure ofAC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-O1 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A Ir maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT I 1.0oE+00 461 TI0000SW Total Loss of Service Water 1 1.00E+00 0.006+00 ACAA50.50A FLAG - OFFSITE POWER MODE 50050 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 9.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-0 1 8.S5E-03

ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPR'767 Loss of Offsite Circuit 767 Folkowing Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failurs of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train 8 I 1.00E+00 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 POF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of flirst 0.1 1.00E-01 462 T10000SW Total Loss of Service Water 1 1.00E+00 0.002+00 ACAASO.LOA FLAG- OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FI8S17 Local Fault on 480 VAC BUs 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-She Power Following Reactor Trip 2.102-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG- DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E÷00 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to 0G (cooling) 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 463 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 825E-01 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Followong ReactorTrip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.002+00 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWrMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.002+00 TRANSX TAG - TRANSIENT EVENT 1 1.002+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.002+00 464 TI00005W Total Loss of Service Water 1 1.00E+00 O.00E+00 ACAASO50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG -0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 465 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAASO 50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-00 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ADOff-Shie Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 466 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAASOS50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIB17 Local Faust on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Ste Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWT"ODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 467 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50.50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Bite Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.002+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 468 TIO000SW Total Loss of Service Water 1 1.002+00 0.002E00 ACAAS0S50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.0112-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01

ACLOPRTALL Loss of AN Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 DGISNOTRUN FLAG - DG8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I l.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWTMPUMP1A 3W Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC 3W Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.002+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 469 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAS0_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 AC82FIBS18 Local Fault on 480 VAC Bus 18 1.01E-OS 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Fallure ofAC Train B 1 1.008+00 DG1ANOTRUN FLAG -0G IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E800 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 470 T10000SW Total Loss of Service Water 1 1.00E+00 O.OOE+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 1ZA) 0.83 5.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.011E-00 I 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AKiOff-Site Power Following Reactor Trip 2.10E-03 2.1OE-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AFAZFAIL)O Non-Elec Failure of all MDAFW pumps Ondependent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR. 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15-803 SWTODG TAG - SW Lost to DG (cooling) 1 1.008+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 471 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.00E-00 ACAA50_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG. DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCVC04603 Service Water Pump PSWIC Discharge Check Valve 4603 Fails To Close On Demand 5.84E-04 1 5.84E-04 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.008+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0.00E+00 472 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.008-01 ACLOPRTALL Loss of ANOff-Site Power Fotowing Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 0G0 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.87E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.008+00 TRANSX TAG - TRANSIENT EVENT I 1.008E00 AAAA FACTOR TO EUMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 473 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.OOE+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2108-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.008E00 ACTRAINB TAG - Falure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - D IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - 00 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWTMPUMP1D SW Pump D In maintenance 7.15E-03 7.158-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+50 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AMAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 474 TI000OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAS5 50A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Alt Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Faoure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.008+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-O1 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.008E00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE IV AND ILLOGICAL CUTSETS 0 0.00E+00 475 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA0S0_S0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG- Faiure of AC Train B 1 1.00E+00 DGlANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.972-01

DG18NOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1 D SW Pump D in maintenance 7.15E-03 7.15E-03 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 6.00E+00 476 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAA5050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Following Reactor Trp 2.12E-03 2.12E-03 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.12E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.008+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 8.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 477 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 8.28E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRT751 Loss of Offsite Circuit 751 Folowing Reactor Trip 2.12E-03 2.12E-03 ACLOPRT767 Loss of Offsite Circuit 767 Following Reactor Trip 2.12E-03 2.128-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.768-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E804 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 ACHFDRCOFF Failure to recover second offsite power circuit after failure of first 0.1 1.00E-01 478 TIO0O0SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAA50J50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.008E+0 AFAZFAILXX Non-Elec Failure of all MDAFW pumps Cindependentof AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 8.97E-01 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-1 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00

.AAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 479 TI00SOOW Total Loss of Service Water 1 1.008+00 0.008+00 ACAASO0.0A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAIL)CX Non-Eloc Failure of all MDAFW pumps (Ondependent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 480 TI0000SW Total Loss of Service Water 1 1.00E+00 0.008+00 ACAAS5050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Sihe Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 DGCCOOORUN DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE) 1.36E-03 1.38E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TRANSX TAG - TRANSIENT EVENT 1 1.008E00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 481 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAASO_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Ali Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 I 9.97E-01 DGCCOORUN DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE) 1.38E-03 1.36E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 482 TI0000SW Total Loss of Service Water 1 1.00E+00O0.00E+00 ACAA50_50A FLAG - OFFSITE POWER MODE S50/SALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5,00E-01 ACLOPRTALL Loss of A)i Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E÷00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DGO IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGDGF0001A DIESEL GENERATOR KDGO1AFAILS TO RUN 1.41E-03 24 3.38E-02 DODGF0001B DIESEL GENERATOR KDG0iB FAILS TO RUN 1.41E-03 24 3.38E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.0012+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21 Eo04 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 483 TI00O0SW Total Loss of Service Water I 1.00E+00 0.00E+00

ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.001-01 ACLOPRTALL Loss of APIOff-She Power Following Reactor Trip 2.110-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG- DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP18NR FLAG - Service Water Pump PSWOIB Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01 D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump 8 in maintenance 0.05 4.556-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DO (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.006+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 O.00E+00 484 TIO00SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACAA5_W50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG- DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG- DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 6.97E-01 NOSED TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG- Service Water Pump PSW0I1B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG- Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.476-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E-00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 485 TI0000SW Total Loss of Service Water 1 1.00E+00 0.002+00 ACAAS0_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trp 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+50 ACTRAINB TAG - Failure of AC Train B 1 1.006+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) 1 15.001+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 5 0.00E+00 486 TI0000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACAASW050A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of AlnOff-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1 006E+0 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR) 1.00E-04 1.006-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.006+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E600 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 487 TI000OSW Total Loss of Service Water I 1.00E+00 5.00E+00 ACAASOWWA FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 126, CKT 767 TO BUS I2A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.002+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 0.03 3.00E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.976-01 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODOG TAG - SW Lost to DG (cooling) 1 1.006+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 488 TI0000SW Total Loss of Service Water 1 1.00E+00 5.006+00 ACAA5050A FLAG- OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of APlOff-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure ofAC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 0.03 3.00E-02 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.00E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.006+00 489 TI0000SW Total Loss of Service Water 1 1.05E+00 0.00E+00 ACAA50._50N FLAG- OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSP1 Failure to Restore Offsite Power Wthin 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip 2.11012-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 11.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGIBNOTRUN FLAG - DG O IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.9712-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 1.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE I 1.00E+00 SWCCIPUMPSR Common Cause Fahure Of Service Water Pumps To Run 1.21E-04 1.2112-04 SWTODG TAG - SW Lost to DO (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 00O.OOE+O0 490 TIOOOSW Total Loss of Service Water 1 1.0012+00 0.0OE+00 ACAASOW50N FLAG - OFFSrTE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACAZDLOSPI Failure to Restore ffshte Power Within 1 Hour 0.38 3.81E-01 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.006-01

ACLOPRTALL Loss of ANOff-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Falure of AC Train A I 1.00E-00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND IS I 9.97E-01 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCIF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 WAA FACTOR TO ELIMINATEUVAND ILLOGICAL CUTSETS O 0.00E+00 491 T10000SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACAASO50N FLAG - OFFSITE POWER MODE 50/60 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B) 0.02 1.70E-02 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 6.85-E03 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL. Loss of All Off-She Power Follow/ng Reactor Trip 2.10E-03 2.10-E03 ACTRAINA TAG - Failure of AC Train A 1 1.008+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGJANOTRUN FLAG - 00 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.768-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 492 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAASO_SON FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of Al Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (Independent of AF300) 0.1 1.00E-01 DGIANOTRUN FLAG - DG; A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00EO00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 493 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAAS0_50N FLAG - OFFSITE POWER MODE W0/50NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of ANOff-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failul of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AFAZFAILXX Non-Elec Failure of all MDAFW pumps (independent of AF300) 0.1 1.008-01 DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SBO TAG - STATION BLACKOUT SEQUENCE 1 1.008+00 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 SWTODG TAG - SW Lost to DG (cooling) I 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.008+00 494 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACAASO_50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 8.00E-01 ACLOPRTALL Loss of AlM Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DG1 BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 SWTODG TAG - SW Lost to D0 (cooling) I 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.008+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 495 T10000SW Total Loss of Service Water 1 1.008+00 0.00E+00 ACAASOL60N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B) 0.02 1.70E-02 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 ACLOPRTALL Loss of All Off-Site Power Following Reactor Top 2.10E-03 2.1OE-03 ACTRAINA TAG - Fallure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 DG1ANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 DGI1NOTRUN FLAG. DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 6.97E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00-E04 SWTODG TAG - SW Lost to DG (cooling) 1 1.00E+00 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 496 TI0000SW Total Loss of Service Water 1 1.00E+00 0.008+00 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACB2FISS18 Local Fault on 480 VAC Bus 1i 1.01E80 I 8&85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.18E-03 5.19E-03 DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED 0.12 1.23E-01 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW duoe to increased stress during loss of SIN to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCIF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause FrazIl Ice and Loss of SW (32/2052 hrs) 0.02 1.66E-02 TRANSX TAG - TRANSIENT EVENT 1 1.008+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 497 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.0181-06 1 8.85E-03 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.65E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 AXXVN09728 3 way vafee 9726 fails to operate 1.00E-03 1 1.00E-03 DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED 0.12 1.23E-01 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazit Ice and Loss of SW (32/2052 hrs) 0.02 1.66E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.008+00 498 T10000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACB2FISS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACB2FTBS1B Local Fault on 480 VAC Bus 18 1.011-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00

ACTRAINB TAG - Failure of AC Train s 1 1.001+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.1SE-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 499 T10000SW Total Loss of Service Water I 1.00E+00 0.OOE+00 ACB2FISS17 Local Fauot on 480 VAC Bus 17 1.01 E-06 1 8.851-03 ACB2FTBS18 Local Fault on 480 VAC Bus 19 1.011-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT 1 t.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS O 0.00E+00 500 T10000SW Total Loss of Service Water 1 1.00E+00 O0OE00 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85M-O3 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1t01SE-O 72 7.275-05 ACTRAINA TAG - Failure of AC Train A 1 1.001+00 ACTRAINB TAG - Failure of AC Train B 1 1.006E00 AXTMSAFSGA SAFW TRAIN C TO SIG A O.O.S. DUE TO TIM 0.02 1.67E-02 AXTMSAFSGB SAFWTRAIN D TO SIG 8 OO.S. DUE TO TIM 0.01 1.49E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS O 0.00+E00 501 TIO000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-00 1 8.85E-03 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 A)0CVN09728 3 way valve 9728 fails to operate 1.0E-03 1 I1.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.OOE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 502 T10000SW Total Loss of Servce Water 1 1.00E+00 0,00E+00 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACB2FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.005+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDD0515N Motor-Operated Valve 515 Is Not Cinsed Due to PORV Leakage 0.97 9.87E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/5156) To Terminate LOCA W/In 3 Min 0.0 5.00E-02 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.005+00 TLSTRANS TAG - TRANSIENT INDUCED SMAlJL LOCA SEQUENCES 1 1.005+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 503 T10000SW Total Loss of Sernvce Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV BElck Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.O0E-O3 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.00E+00 AMAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 504 T10000SW Total Loss of Service Water 1 1.005+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINS TAG - Failure of AC Train B 1 1.005+00 AXCCDMOVNB Common cause failure of MOVs 9701A and 9701B to thmttle flow 7.28E-05 7.28E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 505 T10000SW Total Loss of Service Water I 1.00E+00 0O00E+80 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXCCFSAFWA Common cause failure of SAFW Pumps 1C and ID to ton 1.99E-05 1.99E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.05E+00 506 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AC62FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AXCCSSAFWA Common cause failure of SAFW Pumps 1C and tO to start 8.79E-05 8.79E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.58E-02 TRANSX TAG - TRANSIENT EVENT 1 1 00E+00 507 TI10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.005E+8 AXHFOSAFWX Operators Fat to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.195-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+80 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 508 TI0000WS Total Loss of Service Water 1 1.005+00 0.00E+00 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 AXHFLSAFWA Failure to restore SAFW Pump Train 1C to service post test/maint 3.00E-03 3.00E-03 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 9.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.005+00 509 T10000SW Total Loss of Service Water I 1.00E500 0.OOE+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-06 1 8.85E-03

ACTRAINB TAG - Failure of AC Train B 1 1.OOE+00 AXHFLSAFWA Failure In restore SAFW Pump Train 1C to service post test/maiot 3.00E-03 3.OOE-03 AXTMSAFSGB SAIWTRAIN D TO S/G B O.O.S. DUE TO T/M 0.01 1.40E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.OOE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPlA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 510 T1000OSW Total Loss of Service Water I 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACTRAINB TAG . Failure of AC Train B 1 1.00E+00 AXHFLSAFWB Failure to restore SAFW Pump Train 10 to service post test/maint 3.00E-03 3.SOE-03 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.002+00 PFP PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 511 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFLSAFWB Failure to restore SAFW Pump Train 1D to service post test/maint 3.00E-03 3.00E-03 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M 0.02 1.67E-02 NOSBO TAG - NO STATION BLACKOUT I 1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 512 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01 E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00+E00 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWTMPUMPIA SW Pump Ain maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 513 T10000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.S5E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM 0.02 1.67E-02 AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TOTIM 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUM P1C SW Pump C in maintenance 0.04 3.56E.-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 514 T10000SW Total Loss of Service Water 1 1.OOE+00 O.00E+00 ACS2FIBSI7 Local Fault on 480 VAC Bus 17 1.011-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 AXXVN09728 3 way valve 9728 fails Io operate l.OGE-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWrMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 515 TI7000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-0 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 FSTMFCITYW City Water Supply to Yard Fire Loop Inoperable 4.22E-05 4.22E-05 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIA SW Pump A In maintenance 0.0 3.113E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 516 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.8E-03 ACTRAINB TAG - Failure of AC Train B 1 1.OOE+00 NOSBO TAG - NO STATION BLACKOUT 1 1.OOE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fag To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.0OE+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 517 T7000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-O6 I 8.85E-03 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00516N Motor-Opereted VaNe 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fall To Close PORV Block Valve (515&158)To Terminate LOCA W/In 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam ReFlef 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.008+00 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 518 TI000OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-OB 1 M.85E-03 ACB2FTSS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Cormected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.18E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 519 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACS2FIBS1 8 Local Fault on 480 VAC Bus 18 1.01E-06 0 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.011E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I 1.OOE+00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 AXMMSAFWPC Failure of SAFW Pump 1C train 0.02 2.29E-02 AXMMSAFWPD Fature ofSAFW Pump lD Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 520 TI0000SW Total Loss of Service Water 1 1.00E+00 O.OOE+00 ACB2FIBS18 Local Fault on 480 VAC Bus 16 1.01E-0 1 8.8E-03

ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01 E-06 72 7.27E-05 ACTRAINA TAG - Faluro of AC Train A I 1.00E-00 ACTRAINB TAG - Failure of AC Train B 1 1.ooE+00 AXTMSAFSGA SAFWTRAIN C TO S/G A O.O.S. DUE TO T/M 0.02 1.67E-02 AXTMSAFSGB SAFWTRAIN D TO S/G B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT I i.00E+s0 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 521 TIOO00SW Total Loss of Service Water 1 1.0012+ 0.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 I 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I 1.00El00 ACTRAINB TAG - Failore of AC Train B 1 1.00E+00 A)OCVN09728 3 way value 9728 falls to operate 1.00E-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 TRANSX TAG - TRANSIENT EVENT 1 1.008+00 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS o 0.50E+00 522 TI0O0OSW Total Loss of Senrce Water 1 1.00E+00 0.00E+00 ACB2FIBSIS Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 ACTRAINB TAG - Failure of AC Train B 1 1.08E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Value (515/518) To Terminate LOCA W/tn 3 Min 0.05 5.008-02 RCRZT0431C PORV PCV-431C Fails To Reseal After Steam Relief 5.00E-03 I 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES I 1.000E+0 AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.08E+00 523 T10000SW Total Loss of Service Water I 1.00E+00 .O00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E-00 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.678-01 RCHFOPLOCA Operators Fail To Close PORV Block Value (515/516) To Terminate LOCA WfIn 3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.001+00 AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 524 TIO0000W Total Loss of Senrice Water 1 1.00E+00 0.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXCCDMOVNB Common cause failure of MOVs 9701A and 97018 to throttle flow 7.28E-05 7.28E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1B SW Pump B in maintenance 0.05 4.85E-02 SWTMPUMP1D SW Pump D in maintenance 7.18E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.001+00 525 TI0000SW Total Loss of Senrice Water 1 1.00E+00 0.00E+00 ACB2FIBSS18 Local Fault on 480 VAC Bus 18 1.018-06 1 8.85E-03 ACTRAINA TAG - Failureof AC Train A 1 1.00E+00 AXCCSSAFWA Common cause failure of SAFW Pumps 1C and 1 D to start 8.79E-05 8.79E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-O3 TRANSX TAG - TRANSIENT EVENT 1 1.008+00 528 TI00OOSW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXHFDSAFWX Operators Fail to Correctly Align MAFW (Corrdeed for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correctlon Factor for Operators Failing to arlgn SAFW duoeto increased stress during los of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPI D SW Pump D in maintenance 7.151-03 7.16E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 527 TIO00SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Faillow of AC Train A 1 1.008+00 AXHFLSAFWA Failure to restore FW Pump Train 1C to service post tlsllmaint 3.00E-03 3.00E-03 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-OS 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 528 TIOOOOSW Total Loss of Service Water 1 1.008+00 0.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 I 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXHFLSAFWA oo Falurl nrstore SAFW Pump Train iC to service post test/maint 3.008-O3 3.00E-03 AXTMSAFSGB SAFW TRAIN D TO S/G8 O1O.S. DUE TO T/M 0.01 1.48E-02 NOSSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 529 TI0000SW Total Loss of Service Water I 1.00E+00 0.008+00 ACB2FIBS18 Local Fault on 480 VAC Bus I8 1.01E-08 1 8.85E-03 ACTRAINA TAG - Failure OfAC Train A 1 1.00E+00 AXHFLSAFWB Failure to retore SAFW Pump Train ID to service post tlst/maint 3.00E-03 3.00E-03 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 530 T10000SW Total Loss of Service Water 1 1.00E+80 0.00E+00 ACB2FIBS18 Local FauSt on 480 VAC Bus tI 1.01E-00 I 8.85E-03 ACTRAINA TAG - Falure ofAC Train A 1 1.00E+00 AXHFLSAFWB Failure to restore SAFW Pump Train ID to service pest test/maint 3.00E-03 3.00E-03 AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M 0.02 1.67E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPI B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 531 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00

ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 AXMMSAFWPC Failure of MEW Pump 1C train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump ID Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.1$E-03 tf.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 532 TIOOCOOW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS1S Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXTMSAFSGA SAFWTRAIN C TO S/G A O.O.S. DUE TO T/M 0.02 1.67E-02 AXTMSAFSGB SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M 0.01 1.48E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 533 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBS1S Local Fault on 480 VAC Bus 18 tO0E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 AXMVN09728 3 way valve 9728 fails to operate 1.00E-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPI B SW Pump Bin maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.158-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 534 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 ACB2FIBSIB Local Fault on 480 VAC Bus 18 1.01E-OG I 8.lE-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 FSTMFCITYW CityWater Supply to Yard Fire Loop Inoperable 4.22E-05 4.22E-05 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 535 TI0000SW Total Loss of Service Water I 1.00E+00 0.08E+00 ACB2FIBS18 Local Fault on 480 VAC Bus tS 1.018-00 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA WAn 3 Min 0.05 5.00E-02 RCRZT0431C PORV PCV-431C Fails To Reseal After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.00E+00 SWTMPUMP1I SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 536 TIOOOOSW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-O 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 RCAZDO0516N Motor-Operated Valve 516 Is Not Closed Duo To PORV Leakage 0.97 9.67E-01 RCHFDPLOCA Operators Fail To Close PORV Block Valve (5151518) To Terminate LOCA WIlIn3 Min 0.05 5.00E-02 RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief 5.00E-03 1 5.00E-03 SLO TAG - SMALL LOCA SEQUENCE 1 1.0OE+00 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.151-03 TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 1 1.00E+00 537 TIOOOStW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI000OSW and Some Fire Events For Stress) 5.15E-03 5.18E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress duling loss ofSWto 1 1.93E+00 NOSSO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSWO1A Is Not In Operation 0.42 4.21E-01 SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.50E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 538 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TISOO0SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSWOIA Is Not In Operation 0.42 4.21E-01 SWAASWPICNR FLAG - Service Water Pump PSWO1C Is Not In Operation 0.42 4.21E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 539 TISOCOOW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIO0OOSW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss ofSWto I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSWO1A Is Not In Operation 0.42 4.21E-01 SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance .0,4 3.56E-02 SWTMPUMPI D SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 540 T10000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 POF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSWOIA Is Not In Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSW0IC Is In Operation 0.53 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPI B SW Pump B in maintenance 0.05 4.5512o02 TRANSX TAG - TRANSIENT EVENT I 1.00E+00 541 T10000SW Total Loss of Service Water I 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIOO0SW and Some Fire Events For Stress) 5.19E-03 5.1912-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01

SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0g58 5.79E-01 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.00 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.ISE-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 542 710000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Courected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPtCNR FLAG- Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMPI B SW Pump B in maintenance 0.05 4.55E-02 SWfMPUMPiC SW Pump C In maintenance 0.04 3.56E-02 SWIMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 543 710000SW Total Loss of Service Water 1 1.00E+00 0.00E-00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Conrection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Serice Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D In maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 544 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Falling to align SAFW due to Increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG- Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.94E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 545 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWP1DNR FLAG - Service Water Pump PSWOrID Is Not In Operation 0.42 4.21 E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.00 4.55E-02 SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 545 7100006W Total Loss of Service Water I 1.00E+00 0.00E+00 AXHFOSAFWX Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAPW due to increased stress during loss of SWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPI B SW Pump B in maintenance 0.05 4.55E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 547 T10000SW Total Loss of Service Water 1 1.00E+00 0.000+00 AXHFDSAFWX Operators Fail to Correctly Algn SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Conrrection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.001+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG- Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1A SW Pump A ln maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B In maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 548 TI0000SW Total Loss of Service Water 1 1.00E+00 0.000+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Conrected for TI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due Io increased stress during ioss of SW to 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 &.78E-01 SWAASWPIBNR FLAG - Service Water Pump PSW0 B Is Not In Operation 0.42 4.21E-01 SWPPJIHDRB SERVICE WATER HEADER WB* PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPI B SW Pump B in maintenance 0.05 4.550-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 549 T10000SW Total Loss of Service Water 1 1.00E0+0 O.00+E00 AXHFDSAFWX Operatom Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to Increased strss during loss ofSWfo 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWM1B Is In Operation 0.58 5.79E-01 SWAASWP1DNR FLAG - Service Water Pump PSWOID Is Not In Operation 0.42 4.21E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMP1D SW Pump Din maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.001+00 550 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail Io Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Conrection Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C Sw Pump C in matntenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 551 TI70SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Conectly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03

FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to Increased stress durtng loss of SW to 1 1.93E200 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT I 1.O0E+00 552 TIO000SW Total Loss of Service Water 1 1.002E+0 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TISOOOSWand Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to I 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 I.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 SWrMPUMP1D SW Pump D in maintenance 7.16E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.OOE+00 553 TI000OSW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected forTI0000SW and Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 1.93E-00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIB SW Pump 8 In maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 554 T1000OSW Total Loss of Service Water 1 1.00E+O0 0.00E+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corected for 1I0000SWand Some Fire Events For Stress) 5.1E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Faeling to align SAFW due to iseneed stress duoing los ofSWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0B88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE 5.53E-07 1 4.84E-03 SWIMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 555 TI0000SW Total Loss of Service Water 1 1.00E+00 O.OOE+00 AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIOOOOSWand Some Fire Events For Stress) 5.19E-03 5.19E-03 FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SEWto 1 1.93E+00 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.85 8.76E-01 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWPPJIHDRB SERVICE WATER HEADER 'B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT I 1.00E+00

&%e TS00OSW Total Loss of Service Water 1 1.OOE+00 0.00E+00 AXMMSAFWPC Failure of SAFW Pump IC train 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 229E-02 NOSEO TAG - NO STATION BLACKOUT 1 1.OOE+0O PCF PLANT CAPACITY FACTOR 0e88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump P5N01B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSW01 D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump Bin maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 557 TI0000SW Total Loss of Service Water I 1.00E+D0 0.0OE+00 AXMMSAFWPC Failure of SAFW Pump 1ICtrain 0.02 2.29E-02 AXMMSAFWPD Failure of SAFW Pump 1D Train 0.02 2.29E-02 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW(I1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP 0 TO RUN 0.02 2.47E-02 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 558 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXXVN09728 3 way valve 9728 fails to operate 1.00E-03 1 1.00E-03 NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.762-01 SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWrMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWThmPUMP1C SW Pump C In maintenance 0.04 3.66E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 559 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 AXXVN09728 3 way valve 9728 faio to operate 1.tOE-03 I 1.00E-03 NOSBO TAG - NO STATION BLACKOUT I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.7BE-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1 D Is In Operation 0.58 5.792-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW PumpA to maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 TRANSX TAG - TRANSIENT EVENT 1 1.00E+00 Report Summary:

Frlename: DACAFTA-W\QUANTtLEVELI\@POWERI.CUT Print date: 06/22/2001 1:45 PM Not sorted Printed in full

No.01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING Licensee: . AmerGen Energy Company, LLC Facility: Oyster Creek Nuclear Generating Station Docket No: 05000219 Time and Date: Friday, August 3, 2001, at 10:00 a.m.

Location: U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415

Purpose:

A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.

NRC Attendees: J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)

J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)

V. Ordaz, Chief, Reactor Safeguards Section Chief, NRR D. Orrik, Reactor Security Specialist, NRR L. Dudes, Senior Resident Inspector, Oyster Creek, DRP P. Frechette, Physical Security Inspector, DRS D. Holody, ORA Staff J. Nick, ORA Staff Licensee Attendees: J. Benjamin, Vice President, Licensing and Regulatory Affairs R. DeGregorio, Vice President, Oyster Creek E. Harkness, Plant Manager, Oyster Creek H. McNally, Manager, MAROG Security G. Vanderheyden, Vice President, MAROG J. Hutton, Director, Licensing

2 Note: This meeting is closed to public observation since the matters to be discussed involve Safeguards Information. Attendance by additional NRC personnel to the meeting should be made known by July 25, 2001, to John White, Chief, Radiation Safety and Safeguards Branch, Region 1, at 610-337-5114.

Approved By:

John F. Rogge, Chief Projects Branch 7 Division of Reactor Projects

3 Distribution:

DOCUMENT NAME: G:\RSSB\FRECHET'ROCMTGNOTICE.WPD After declaring this document "An Official Agency Record" it will/will not be released to the Public.

OFFICE NAME DATE RI/DRS PFrechette 07/17/01 RI/DRS JWhite 07/ /01 H

To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure RI/DRP JRogge 107/ /01 "E" = Copy with attachment/enclosure 07/ /01 07/ /01 "N"= No copy OFFICIAL RECORD COPY

No.01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING Licensee: AmerGen Energy Company, LLC Facility: Oyster Creek Nuclear Generating Station Docket No: 05000219 Time and Date: Friday, August 3, 2001, at 10:00 a.m.

Location: U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415

Purpose:

A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.

NRC Attendees: J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)

J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)

V. Ordaz, Chief, Reactor Safeguards Section Chief, NRR D. Orrik, Reactor Security Specialist, NRR L. Dudes, Senior Resident Inspector, Oyster Creek, DRP P. Frechette, Physical Security Inspector, DRS D. Holody, ORA Staff J. Nick, ORA Staff Licensee Attendees: J. Benjamin, Vice President, Licensing and Regulatory Affairs R. DeGregorio, Vice President, Oyster Creek E. Harkness, Plant Manager, Oyster Creek H. McNally, Manager, MAROG Security G. Vanderheyden, Vice President, MAROG J. Hutton, Director, Licensing

2 Note: This meeting is closed to public observation since the matters to be discussed involve Safeguards Information. Attendance by additional NRC personnel to the meeting should be made known by July 25, 2001, to John White, Chief, Radiation Safety and Safeguards Branch, Region 1, at 610-337-5114.

Approved By:

John F. Rogge, Chief Projects Branch 7 Division of Reactor Projects

3 Distribution:

(Note: Include: OE Mail; PMNS; OE Web; and S. Bogle, OE)

DOCUMENT NAME: G:\RSSB\FRECHETT\OCMTGNOTICE.WPD After declaring this document "An Official Agency Record" it will/will not be released to the Public.

To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N"= No copy OFFICE RI/DRS RI/DRS RI/DRP L NAME PFrechette JWhite JRogge DATE 07/17/01 07/ /01 07/ /01 07/ /01 07/ /01 OFFICIAL RECORD COPY

Cutsets with Descriptions Report a LSW-INIT1 = 2.01E-04 DI.CAFTA- 06/22/2001 13:15 Inputs Description Rate Exposure Event Pinb Probabtlity 1 TI00OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR 1 1.00E200 1.06E-04 SWCCIPUMPSR 0.88 8.76E-01 Common Cause Failure Of Service Waoter Pumps To Run 2 TIOOOOSW 1.21E-04 1.21E-04 Total Loss of Service Water PCF 1 1.0E++00 8.76E-05 PLANT CAPACITY FACTOR SWCXXSUCTI 0.88 8.76E201 TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 3 TIOOOSW Total Loss of Service Water ACB2FIBS18 1 1.00E+00 1.16E-06 Local Fault on 480 VAC Bus 18 ACTRAINA 1.01E-06 1 8.80E-03 TAG - Failure of AC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWMMOSWPDS 0.88 8.76E-01 FAILURES OF SW PUMP D TO START SWTMPUMPI B 3.28E-03 3.28E-03 SW Pump B in mainrenance 4 TI0000SW ACB2FIBS17 Total Loss of SerNce Water Local Fault on 480 VAC Bus 17 1.01E-06 0.05 1

1 4.55E-02 1.00E+00 8.85E-03 9.05E-07 LO0SLOŽ.XKL SS ACTRAINS TAG - Failure Of AC Train S PCF PLANT CAPACITY FACTOR 1 1.00E+00 SWMMOSWPAO 0.88 8.78E-01 FAILURES OF SW PUMP A TO START SWTMPUMPIC 3.28E-03 3.28E-03 SW Pump C in maintenance 5 TIOOOOSW Total Loss of Service Water 0.04 3.56E-02 1 1.002+00 8.84E-07 ACB2FISS17 Local Fault on 480 VAC Bus 17 ACTRAINB 1.01E-06 1 8.85E-03 TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR 1 1.00E+00 SWCCPUMPSS 0.88 8.76E-01 Common Cause Fa/ure Of Service Water Pumps To Start 6 TI0000SW 1.14E-04 1.14E-04 Total Loss of Service Water ACB2FIBS18 1 1.002+00 8.84E-07 Local Fauh on 480 VAC Bus 18 1.01E-06 1 8.85-E03 ACTRAINA TAG - Failure ofAC Train A PCP PLANT CAPACITY FACTOR 1 1.00E+00 SWCCPUMPSS 0.88 8.76E-01 Common Cause Failure Of Service Water Pumps To Start 7 TIO00OSW Total Loss of Service Water 1.14E-04 1.14E-04 ACB2FIBSI7 1 1.00E+00 7.96E-07 Local Fault on 480 VAC Bus 17 1012-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train 8 PCF PLANT CAPACITY FACTOR 1 1.0E-+00 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3,28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 8 TI0000SW .003 3.13E-02 Total Loss of Service Water ACB2FIBS17 1 1.00E+00 5.64E-07 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E.03 ACB2FTSS18 Local Fault on 480 VAC Bus 18 ACTRAINA 1.012-06 72 7.27E-05 TAG - Failure ofAC Train A ACTRAIN TAG - Pailure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 1 1.00E+00 9 TIOOOOSW 0.88 8.76E-01 Total Loss of Service Water ACE2FIBS18 1 1.00E+00 5.64E-07 Local Fault on 480 VAC Bus 18 1.01 E-06 1 8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 ACTRAINA 1.01E-56 72 7.27E-05 TAG - Failure of AC Train A ACTRAIN 1 1,00E+00 TAG - Pailunmn/AC Train B PCF 1 1.00E+00 PLANT CAPACITY FACTOR 10 TIOOOSW Total Loss of Service Water 0.88 8.76E-01 ACB2FIBS18 1 1.00E+00 1.82E-07 Local Fault on 480 VAC Bus 10 ACTRAINA 1.01E-06 1 8.85E-03 TAG - Fa/lure of AC Train A PCF 1 1.05E-00 PLANT CAPACITY FACTOR SWMMOSWPBS 0.88 8.76E-01 FAILURES OF SW PUMP B TO START SWTMPUMPID 3.28E-03 3.28E-03 SW Pump D io maintenance 11 TI0000SW 7.15E-03 7.15E-03 Total Loss Of Service Water ACB2FIBS17 1 1.00E+00 1.40E-07 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACB2FIBS1E Local Fault on 480 VAC Bus 18 ACTRAINA 1.01E-06 1 8.85E-03 TAG - Fa/lure of AC Train A ACTRAIN 1 1.00E+00 TAG - Pa/ouren/AC Trains DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS< 30 DEGREES AND 1 1.00E+00 INTAKE HEATERS ENE 0.12 1.23E-01 PCF PLANT CAPACITY FACTOR SWAZINTAKE 0.88 8.76E-01 Assumption that Lake Temperature Is Cold Enough to Cause Frazil 12 T10000SW Ice and Loss of SI (3 0.02 1.66E-02 Total Loss of Service Water ACB2FIBS18 1 1.00E+00 1.19E-07 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure ofAC Train A PCF PLANT CAPACITY FACTOR 1 1.00E+00 SWAASWPICR 0.88 &.76E-01 FLAG - Service Water Pump PSW01C Is In Operation SWCVC04603 0.58 5.79E-01 Service Water Pump PSWOIC Discharge Check Valve 4603 Fails To Close On 5.84E-04 1 5.84E-04 SWTMPUMPI B SW Pump B In maintenance 13 TI0OOOSW Total Loss of Service Water 0.05 4.55E-02 ACB2FIBS17 1 1.00E+00 9833E-08 Local Fault on 480 VAC Bus 17 ACTRAINB 1.01E-06 I 8.85E-03 TAG - Failure of AC TrainO I 1.00E+00 PCF PLANTCAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWI0B Is In Operation 0.88 8.76E-01 SWCVC04602 Service Water Pump PSWOI B Discharge Check Valve 4602 Fails 0.88 5.79E-01 To Close On 5.84E804 1 5.84E-04 SWTMPUMPIC SW Pump C in maintenance 14 T10000SW Total Loss of Service Water 0.04 3.562-02 1 1.00E+00 8.342-0 ACB2PIBS17 Local Fault on 480 VAC Bus 17 ACTRAINB 1.01E-06 1 8.85E-03 TAG - Failure ofAC Train B PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWMMOSWPAS 0.88 8.76E-01 FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E.03 3.28E-03 15 TI00OSW Total Loss of Service Water ACB2FIBSI8 1 1.00E200 8.34E-08 Local Fault on 480 VAC Bus Ia ACTRAINA 1.01E-06 1 8.85E-03 TAG - Failure ofAC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWMMOSWPBS 0.88 8.78E-01 FAILURES OF SW PUMP B TO START SWMMOSWPDS 3.28E-03 3.28E-03 FAILURES OF SW PUMP D TO START 18 TI0000SW 3.28E-03 3.28E-03 Total Loss of Service Water ACB2FIBS17 1 1.00E+00 8.20E-08 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure ofAC Train B PCF 1 1.002+00 PLANT CAPACITY FACTOR SWAASWPIDR 0.88 8.76E-01 FLAG - Service Water Pump PSWO1D Is In Operation SWCVC04604 0.58 5.79E-01 Service Water Pump PSW01D Discharge Check Valve 4604 Fails To Close On 5.94E.04 1 5.84E-04 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT SWTMPUMPIA SW Pump A in maintenance 1 1.00E+00 17 TI00OOSW Total Loss of Service Water 0.03 3.132-02 ACB2FIBS18 1 1.00E+00 7.222-08 Local Fault on 480 VAC Bus 18 ACTRAINA 1.01E-06 1 8.85E-03 TAG - Failure of AC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWMMSWPDRT 0.88 8.76E-01 FAILURES OF SW PUMP D TO RUN SWTMPUMPIB 2.05E-04 2.052-04 SW Pump B in maintenance 10 TI0000SW Total Loss of Service Water 0.00 4.552-02 PCF 1 1.002+00 5.892-08 PLANT CAPACITY FACTOR SWAASCREEN 088 8.70E-01 FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWSOIA 1.002-06 1 &.78E-03 SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWSO1B SWISFFSWCI 1.00E-06 1 8.76E-03 PLUGGING OF TRAVELLING SCREEN FWS01C 19 TIOOOOSW 1.00E-06 1 8.76E-03 Total Loss of Service Water PCF 1 1.00E+00 5.89E208 PLANT CAPACITY FACTOR 0.88 8.76E-01

SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWSO1A 1.00E-06 1 8&78E-03 SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWS01B 1.00E-06 I 8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS010 1.001-06 1 8.76E-03 20 TIO0OOSW Total Loss of Service Water 1 1.00E.00 5.89E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-C1 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWS01A 1.00E-06 1 8.76E-03 SWTSFFSWCI PLUGGING OF TRAVELLING SCREEN FWS01C 1.00E-08 I 8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS01D 1.00E-06 1 8.76E-03 21 TI0000SW Total Loss of Service Water 1 1.00E+00 5.89E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-O SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWS01B 1.00E-06 1 8.76E-03 SWTSFFSWCI PLUGGING OF TRAVELLING SCREEN FWS01C 1.001-06 1 8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS01D 1.00E-068 8.78E-03 22 TI0000SW Total Loss of Service Water 1 1.008+00 5.65E-08 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 I 8.85E-03 ACTRAINB TAG - Failure of AC Train E 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 23 TI0000SW Total Loss of Service Water 1 1.00E+00 4.96E-08 AC82FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.851-03 ACTRAINB TAG - Failure of AC Train 8 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWTMPUMP1A SW Pump A inmaintenance 0.03 3.13E-02 24 TI0000SW Total Loss of Service Water 1 1.00E+00 2.80E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWMlA Is In Operation 0.58 5.79E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMPI B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 25 TI00O0SW Total Loss of Service Water I 1.00E+00 2.80E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSWOIB Is Not In Operation 0.42 4.21 E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 0.00 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 26 TI0000SW Total Loss of Service Water 1 1.008+00 2.74E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPDRI FAILURES OF SW PUMP 0 TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump S in maintenance 0.05 4.55E-02 27 TI0000SW Total Loss of Service Water 1 1.00E+00 2.68E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 28 TI0000SW Total Loss of Service Water 1 1.00E+00 2.14E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E801 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICNR FLAG- Service Water Pump PSWOIC Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 29 TI0000SW Total Loss of Service Water 1 1.00E+00 2.09E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 6.78E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 30 TI000OSW Total Loss of Service Water PCF 1 1.00E+00 2.05E-08 PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.88 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN.

0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 31 TI0000SW Total Loss of Service Water 1 1.00E+00 2.05E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01 D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPBRI FAILURES OF SW PUMP 8 TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 32 TI00O0SW Total Loss of Service Water 1 1.00E+00 1.88E-08 PCF PLANT CAPACITY FACTOR 0.88 8.761-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.88 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 33 TI0000SW Total Loss of Service Water 1 1.00E+00 1.87E-08 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.06E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWCVC04601 Service Water Pump PSW0IA Discharge Check Valve 4801 Fais To Close On 5.84E-04 1 6.84E-04 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.158-03 34 TI0000SW Total Loss of Service Water 1 1.00E+00 1.84E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1OR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Iotn Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1A SWPumpA in maintenance 0.03 3.13E-02 35 TI0000SW Total Loss of Service Water 1 1.00E+00 1.75E-08 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 36 TIOOOOSW Total Loss of Service Water 1 1.00E+00 1.37E-08 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-CO 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.0OE÷00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWPICNR FLAG - Service Water Pump PSWO1C Is Not In Operation 0.42 4.21E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 37 T10000SW Total Loss of Service Water 1 1.00E+00 1.30E-08 AC82FTBS17 Local Fault on 480 VAC Bus 17 1.018-06 72 7.27E-05 ACTRAINB TAG - Faiur OfAC Train B 1 1.008+00 PCO PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWOlA Is In Operation 0.58 5.79E.01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 38 TISOOOSW Total Loss of Service Water 1 1.00E+00 1.30E-08 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWoIB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 39 TSOOOOSW Total Loss of Service Water 1 1.OE-.00 1.20E-08 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failura of AC Train B 1 1.00E800 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSWO1A Is Not In Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 40 TIOOOOSW Total Loss of Service Water 1 1.008E00 1.12E-08 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 41 TI0000SW Total Loss of Service Water 1 1.00E800 9.49E-09 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWMvIMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER "0" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 42 TIOOOOSW Total Loss of Service Water 1 1.00+O00 9.49E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.211E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 43 TIOODOSW Total Loss of Service Water 1 1.00E+00 9.27E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1B SW Pump s in maintenance 0.05 4.55E-02 44T10000SW Total Loss of Service Water 1 1.00E+00 9.06E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1B SW Pump B In maintenance 0.05 4.555-02 45 Ti0000SW Total Loss of Service Water 1 1.0OE+00 9.06E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1B SW Pump B In maintenance 0.05 4.55E-02 46 TIOOOSW Total Loss of Service Water 1 1.00E+00 8.608-09 ACB2FIB17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.855-03 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW1 B Is In Operation 0.58 5.79E-01 SWCVC04602 Service Water Pump PSWO1 B Discharge Check Valve 4602 Fails To Close On 5.84E-04 1 5.84E-04 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.285-03 3.28E-03 47 TIOOOOSW Total Loss of Service Water 1 1.00E+00 8.60E-09 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINS TAG - Failure of AC Train B 1 1.001200 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1DR FLAG- Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCVC04604 Service Water Pump PSWO1D Discharge Check Valve 4604 Falls To Close On 5.84E-04 1 5.84E-04 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT 1 1.00E+00 48 TISOOOSW Total Loss of Service Water 1 1.00E+00 8.60E-09 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.005+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG- Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWCVC04601 Service Water Pump PSW01A Diclsarge Check Valve 4601 Fails To Close On 5.84E-04 1 5.84E-04 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 49 TI00OOSW Total Loss of Service Water 1 1.00E+00 8.60E-09 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 5.76E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCVC04603 Service Water Pump PSW01C Discharge Check Valve 4603 Falls To Close On 5.84E-04 1 5.84E-04 SWMMOSWPSS FAILURES OF SW PUMP S TO START 3.28E-03 3.28E-03 50 TI0000SW Total Loss of Service Water 1 1.00E+00 7.26E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICNR FLAG - Service Water Pump PSWO1C Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Comnmon Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 6.53E-07 1 4.84E-03 SWtMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 51 TI000OSW Total Loss of Service Water 1 1.00E+00 7.09E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B I In Operation 0.58 5.79E-01

SWMMOSWPAS FAILURES OF SIN PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 52 T10000SW Total Loss of Service Water 1 1.00E+00 7.09E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 53 T10000SW Total Loss of Service Water 1 1.00E+00 6.83E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "8" PIPING RUPTURE 5.53E-07 I 4.04E-03 54 T10000SW Total Loss of Service Water I 1.00E+00 6.93E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B"PIPING RUPTURE 5.53E-07 I 4.84E-03 55 T10000SW Total Loss of Service Water 1.00E+00 6.93E-09 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1CR FLAG - Service Water Pump PSW0t C Is In Operation SWCCPUMPSS 0.08 5.79E-01 Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A"PIPING RUPTURE 5.53E-07 1 4.84E-03 56 TI0000SW Total Loss of Service Water 1 1.00E+00 6.93E-09 PCF PLANT CAPACITY FACTOR 0.80 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW0ID It In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.04E-03 57 1I0000SW Total Loss of Servica Water 1 1.00E+00 6.38E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E0-04 1.14E-04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.04E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 58 T10000SW Total Loss of Service Water 1 1.00E+00 6.23E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW0lB Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRB 0.02 2.47E-02 SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E0-3 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 59 T10000SW Total Loss of Service Water 1 1.00E+00 6.23E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1DR FLAG - Service Water Pump PSW01 D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA 0.02 2.47E-02 SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1A SW Pump A in maintenance 60 TI0000SW 0.03 3.130-02 Total Loss of Service Water 1 1.00E+00 5.91E-09 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.0tE-0B 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 PCF 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW1 B Is Not In Operation 0.42 4.21E-01 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIB SW Pump B in maintenance 61 TOOSOOSW 0.05 4.550-02 Total Loss of Service Water I ACB2FIBS17 1.00E+00 5.20E-09 Local Fault on 480 VAC Bus 17 1.01 E-06 1 8.80E-03 ACTRAINB TAG - Failure of AC Train B I PCF 1.00E+0O PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.03E-04 2.05E-04 62 TI0000SW Total Loss of Service Water I ACB2FIBS17 1.00E+00 0.20E-09 Local Fault on 480 VAC Bus 17 1.01 E-08 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B 1 PCF 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPART 3.28E-03 3.280-03 FAILURES OF SERVICE WATER PUMP A TO RUN 63 T10000SW 2.OE-04 2.05E-04 Total LOSSof Service Water I ACB2FIBS18 1.00E+00 5.20E-09 Local Fault on040 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 PCF 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMSWPDRT 3.28E-03 3.28E-03 FAILURES OF SW PUMP D TO RUN 64 TI0000SW 2.05E-04 2.05E-04 Total Loss of Service Water ACB2FIPS18 1.000+00 5.13E-09 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A PCF 1.00E+00 PLANT CAPACITY FACTOR SWMMOSWPDS 0.80 8.76E-01 FAILURES OF SW PUMP D TO START SWMMSWPBRT 3.28E-03 3.281-03 FAILURES OF SW PUMP B TO RUN 65 T10000SW 2.02E-04 2.02E-04 Total Loss of Service Water I ACB2FTBS17 1.00E+00 4.83E-00 Local Fault on 480 VAC Bus 17 ACTRAINB 1.01E-06 72 7.27E-05 TAG - Failure of AC Train B 1 PCF 1.00E+00 PLANT CAPACITY FACTOR SWAASWP1CNR 0.88 8.76E-01 FLAG - Service Water Pump PSW01C Is Not In Operation SWPPJIHDRA SERVICE WATER HEADER *A"PIPING RUPTURE 0.42 4.21E-01 SWTMPUMPIC 5.53E-07 1 4.94E-03 SW Pump C in maintenance 66 TI0000SW 0.04 3.56E-02 Total Loss of Service Water 1 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.O0E+00 4.42E-09 ACTRAINB 1.01E-06 72 7.27E-05 TAG - Failure of AC Train S 1 PCF PLANT CAPACITY FACTOR 1.00E+00 SWAASWP1AR 0.88 8.76E-01 FLAG - Service Water Pump PSW01A Is In Operation SWMMSWPARI 0.58 5.79E-01 FAILURES OF SERVICE WATER PUMP A TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 0.02 2.47E-02 67 T10000SW 5.53E-07 1 4.84E-03 Total Loss of Service Water 1 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.00E+00 4.42E-09 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train s 1 PCF PLANT CAPACITY FACTOR 1.00E+00 SWAASWP1CR 0.88 8.76E-01 FLAG - Service Water Pump PSWO0C Is In Operation SWMMSWPCRI 0.58 5.79E-01 FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 0.02 2.47E-02 88 TI000OSW 5.53E-07 1 4.84E-03 Total Loss of Service Water 1 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.000+00 4.42E-09 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 PCF PLANT CAPACITY FACTOR 1.00E+00 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.88 8.76E-01 SWMMSWPBRI 0.58 5.79E-01 FAILURES OF SW PUMP B TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 0.02 2.47E-02 5.53E-07 1 4.04E-03

69 TI0000SW Total Loss of Service Water I 1.00E+00 4.42E-00 ACB2FTBSl8 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Faulure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE 5.53E-07 1 4.84E-03 70 TI000SW Total Loss of Service Water 1 1.00E+00 4.300-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPtBR FLAG - Service Water Pump PSW01t Is In Operation 0.58 5.79E-01 SWAASWP1 DNR FLAG - Service Water Pump PSWO1D Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPERI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWTMPUMPtD SW Pump D in maintenance 7.15E-03 7.151-03 71 T10000SW Total Loss of Service Water 1 1.000+00 4.21E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPtAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.780E01 SWMMOSWPBS FAILURES OF SW PUMP S TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMP1 0 SW Pump D in maintenance 7.16E-03 7.15E-03 72 Ti0000SW Total Loss of Service Water I 1.00E+00 4.07E-09 ACE2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIANR FLAG - Service Water Pump PSWOtA Is Not In Operation 0.42 4.21E-01 SWPPJIHDRB SERVICE WATER HEADER 8E"PIPING RUPTURE 6.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 313E-02 73 TI00OOSW Total Loss of Service Water 1 1.00E+00 3.87E-09 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.78E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMIMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 74 Ti0000SW Total Loss of Service Water 1 1.00E+00 3.87E-09 PCF PLANT CAPACITY FACTOR 0.88 8.70E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1 DNR FLAG - Service Water Pump PSWOID Is Not In Operation 0.42 4.21E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.280E-03 SWMMSWPBRI FAILURES OF SW PUMP S TO RUN 0.02 2.47E-02 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWrMPUMPID SW Pump D in maintenance 7.1SE-03 7.15E-03 75 TI00OQSW Total Loss of Service Water I 1.00E+00 2.74E-09 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.0112-0 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPI BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWMMSWPBRI FAILURES OF SW PUMP S TO RUN 0.02 2.47E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 78 TI000OSW Total Loss of Service Water I 1.00E+00 2.58E-08 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation SWAASWP1 DR 0.42 4.21E-01 FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.280-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.280E-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1B 0.02 2.47E-02 SW Pump B in maintenance 77 Ti0000SW 0.05 4.55E-02 Total Loss of Service Water 1.00E+00 2.02E-09 PCF PLANT CAPACITY FACTOR SWAASWPIAR 0.88 8.78E-01 FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICNR 0.58 5.79E-01 FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMOSWPES FAILURES OF SW PUMP S TO START 3.28E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPARI 3.28E-03 3.28E-03 FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMPIC SW Pump C in maiatenance 78 TI0000SW 0.04 3.56E-02 Total Loss of Service Water PCF 1.00E+00 1.93E-09 PLANT CAPACITY FACTOR SWAASWPIAR 0.88 8.761-01 FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 0.58 5.79E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS 3.28E-03 3.28E-03 FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPCRI 0.02 2.47E-02 FAILURES OF SW PUMP C TO RUN 79 Ti0000SW Total Loss of Service Water 0.02 2.47E-02 PCF 1.00E+00 1.83E-09 PLANT CAPACITY FACTOR SWAASWP1BR 0.88 8.76E-01 FLAG - Service Water Pump PSWO1E Is In Operation SWAASWP1DR 0.58 5.79E-01 FLAG - Service Water Pump PSW01D Is In Operation SWMMOSWPAS 0.58 5.70E-01 FAILURES OF SW PUMP A TO START SWMMOSWPCS 3.280E-03 3.28E-03 FAILURES OF SW PUMP C TO START SWMMSWPSRI 3.28E-03 3.28E-03 FAILURES OF SW PUMP B TO RUN SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 80 TI0000SW Total Loss of Service Water 0.02 2.47E-02 1.00E+00 1.78E-09 PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.88 8.78E-01 SWAASWP1CR 0.42 4.21 E-01 FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPBS 0.28 5.79E-01 FAILURES OF SW PUMP B TO START 3.28E-03 3.280E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPCRI 3.20E-03 3.28E-03 FAILURES OF SW PUMP C TO RUN 0.02 SWTMPUMPIA 2.47E-02 SW Pump A In maintenance 0.03 3.13E-02 81 T10000SW Total Loss of Service Water PCF 1.00E+00 1.75E-09 PLANT CAPACITY FACTOR 0.88 SWAASWPIAR 8.760-01 FLAG - Service Water Pump PSW0tA Is In Operation 0.58 SWAASWPICNR 5.79E-01 FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 SWMMSWPARI 4.21E-01 FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 SWMMSWPDRT 2.47E-02 FAILURES OF SW PUMP D TO RUN 2.05E-04 SWTMPUMPIB 2.05E-04 SW Pump Bin maintenance 0,05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 82 TI0000SW 3.56E-02 Total Loss of Service Water PCF 1.00E+00 1.75E-09 PLANT CAPACITY FACTOR 0.88 SWAASWP1BNR FLAG - Service Water Pump PSW0I8 Is Not In Operation 8.78E-01 0.42 SWAASWPIDR 4.21E-01 FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 5.70E-01 2.05E-04 SWMMSWPDRI 2.05E-04 FAILURES OF SW PUMP D TO RUN 0.02 SWTMPUMP1B 2.47E-02 SW Pump S in maintenance 0.05 SWTMPUMPIC 4.55E-02 SW Pump C in maintenance 0.04 83 TI0000SW 3.56E-02 Total Loss of Service Water PCF 1.000+00 1.67E-0M PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 8.78E-01 0.58 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 5.70E-01 0.58 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 5.79E-01 0.02 2.47E-02

SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 SWTMPUMPIS SW Pump B in maintenance 0.05 4.55E-02 84 TIOO00SW Total Loss of Service Water 1 1.00E-00 1.48E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWPPJIHDRA SERVICE WATER HEADER "A"PIPING RUPTURE 5.53E-07 1 4.84E-03 SWIMPUMPID SW Pump D In maintenance 7.19E-03 7.15E-03 85 TI0000SW Total Loss of Service Water I PCF 1.00E+00 1.42E-09 PLANT CAPACITY FACTOR 0.88 SWAASWP1AR 8.76E-01 FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B' PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 88 T10000SW Total Loss of Service Water 1 1.00E+00 1.42E-09 PCF PLANT CAPACITY FACTOR 0.88 8.70E-01 SWAASWPICR FLAG - Service Water Pump PSW0IC Is In Operation 0.58 5.79E-01 SWMMOSWPBS FAILURES OF SW PUMP S TO START 3.28E-03 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 87 TI0000SW Total Loss of Service Water I PCF 1.00E+00 1.31E-09 PLANT CAPACITY FACTOR 0.88 SWAASWPIANR 8.78E-01 FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 SWMMOSWPSS 4.2112-01 FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER'S" PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMPIA SW Pump A inmaintenance 0.03 3.13E-02 SWTMPUMPID SW Pump D In maintenance 7.15E-03 7.15E-03 88 TI0000SW Total Loss of Service Water I 1.00E+00 1.31E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A"PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 88 T10000SW Total Loss of Service Water 1 PCF PLANT CAPACITY FACTOR 1.00E+00 1.31E-09 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWIB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID ls In Operation 0.58 5.79E-01 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 90 TIOO00SW Total Loss of Service Water 1 1.00E+00 1.15E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIB R FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW1ID Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP S TO RUN 0.02 2.47E-02 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 91 T10000SW Total Loss of Service Water I ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.00E+00 9.29E-10 1.01E-08 72 ACTRAINA TAG - Failure of AC Train A 7.27E-05 1 1.000+00 PCF PLANT CAPACITY FACTOR 0.83 8.76E-01 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.150-03 92 TI0000SW Total Loss of Service Water 1 1.00E+00 8.86E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACTRAINS TAG - Failure of AC Train B 1 1.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1SR FLAG - Service Water Pump PSW01S Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCVC04602 Service Water Pump PSWO1S Discharge Check Valve 4602 PFaisTo Close On 5.84E.04 1 5.84E-04 SWCVC04604 Service Water Pump PSWO1D Discharge Check Valve 4804 Fails To Close On 6.84E-04 1 &.84E-04 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT 1 1.00E+00 93 TI0000SW Total Loss of Service Water I ACS2FIBS18 Local Fault on 480 VAC Bus 18 1.00E+00 8.86E-10 1.01E-06 1 ACTRAINA TAG - Failure of AC Train A 8.85E-03 I

PCF PLANT CAPACITY FACTOR 1.00E+00 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 SWCVCD4601 Service Water Pump PSW01A Discharge Check Valve 4601 Falls To Close On 5.84E-04 5.79E-01 1

SWCVC04603 Service Water Pump PSW01C Discharge Check Valve 4603 Fais To Close On 5.84E-04 5.84E-04 1 5.84E-04 94 T10000SW Total Loss of Serifce Water 1 PCF PLANT CAPACITY FACTOR 1.00E+00 8.75E-10 0.88 SWAASWPIBNR FLAG - Service Water Pump PSW01 B Is Not In Operation 8.76E-01 0.42 4.21E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER "B' PIPING RUPTURE 3.28E-03 5.53E-07 1 SWTMPUMP1 B SW Pump B in maintenance 4.84E-03 0.05 4.55E-02 95 T10000SW Total Loss of Service Water 1 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.00E+00 8.70E-10 1.01E-06 1 ACTRAINB 8.85E-03 TAG - Failure of AC Train BS DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 1.00E+00 0.12 PCF PLANT CAPACITY FACTOR 1.23E-01 0.88 SWAZINTAKE Assumption that Lake Temperature Is Coad Enough to Cause Frazil Ice and Loss of SW (3 8.76E-01 0.02 SWHHFCWOIA Circulating Water Intake Heater CWO1A Pails 1.686-02 2.29E-08 24 96 11D000SW 5.50E-05 Total Loss of Service Water I ACB2FISS17 Local Fault on 480 VAC Bus 17 1.00E+08 8.70E-10 1.010-06 1 ACTRAINB TAG - Failure of AC Train B 8.85E-03 1

DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 1.00E+00 0.12 PCF PLANT CAPACITY FACTOR 1.23E-01 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (3 8.76E-01 0.02 1.66E-02 SWHHFCW01C Circulating Water Intake Heater CW01C Fails 2.29E-08 24 97 TIOOOOSW Total Loss of Service Water 5.50E-05 1

ACB2FIBS18 Local Fault on 480 VAC sus18 1.00E+00 8.70E-10 1.01E-06 1 ACTRAINA TAG - Failure of AC Train A 8.85E-03 1

DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 1.00E+00 0.12 PCF PLANT CAPACITY FACTOR 1.23E-01 0.88 SWAZINTAKE Assumption that Lake Temperature Is Coal Enough to Cause Frazn Ice and Loss of I (3 8.78E-01 0.02 SWHHFCW01S Cirulating Water intake Heater CW018 Fails 1.66E-02 2.29E-08 24 98 T10000SW Total Loss of Service Water 5.50E-05 1

ACB2FIBS10 Local Fault on 480 VAC Bus 18 1.00E÷00 8.70E-10 1.010-08 1 ACTRAINA TAG - Failure of AC Train A 8.85E-03 1

DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 1.00E+00 0.12 PCF PLANT CAPACITY FACTOR 1.23E-01 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SIN (3 8.76E-01 0.02 SWHHFPCW01D Circulating Water Intake Heater CWOID Fails 1.66E-02 2.29E-06 24 99 T10000SW Total Loss of Service Water 5.50E-05 I

PCF PLANT CAPACITY FACTOR 1.00E+00 8.85E-10 0.88 8.78E-01

SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.288E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.288E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A"PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 100 TIOOOOSW Total Loss of Service Water 1 1.00E+00 6.54E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.78E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.281E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28 E8-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 101 Tt000OSW Total Loss of Service Water 1 1.00E000 8.84E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG- Service Water Pump PSWi1B Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.288E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.288E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER 0"BPIPING RUPTURE 5.53E-07 1 4.84E-03 102 TIO000SW Total Loss of Service Water 1 1.00E+00 8.54E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28 E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28 E-03 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 103 TI0000SW Total Loss of Service Water 1 1.000200 6.54E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28 E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28 E-03 3.28E-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER A PIPING RUPTURE 5.53E-07 1 4.84E-03 104 TI000OSW Total Loss of Service Water 1 1.00E+00 6.02E-10 PCF PLANT CAPACITY FACTOR 0.89 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSWOIA Is Not In Operation 0.42 4.21E801 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28EE-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.281E-03 3.28E-03 SWPPJIHDRE SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 105 TI0000SW Total Loss of Service Water 1 1.00E+00 5.92E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BNR FLAG - Service Water Pump PSWO1 B Is Not In Operation 0.42 4.21E-01 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2 E-04 2.05E-04 SWPPJIHDRB SERVICE WATER HEADER "fr"PIPING RUPTURE 5.53E-07 2.05E 1 4.84E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.58E-02 106 TI0000SW Total Loss of Service Water 1 1.00E+00 5.92E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWPPJIHDRA E-04 2.05E-04 SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance 1.84 3.561-02 107 TI0000SW Total Loss of Service Water 1 1.00E+00 5.88E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 2.05E1.58 5.79E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPDRT 1.02 2.47E-02 FAILURES OF SW PUMP D TO RUN 2 .05E -04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 2.05E-04 5.53E-07 1 4.84E-03 SWTMPUMPIB SIN Pump B in maintenance 0.05 4.55E-02 108 T10000SW Total Loss of Service Water 1 1.00E+00 5.65E-10 PCF PLANT CAPACITY FACTOR

'.88 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0 '.58 5.79E-01 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 0 '.02 2.47E-02 2 -04 2.05E-04 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 SWTMPUMP1B SW Pump B in maintenance 0 1 4.84E-03

.05 4.55E-02 109 710000SW Totat Loss of Serace Water ACB2FIBS17 1 1.00E+00 5.36E-10 Local Fault on 480 VAC Bus 17 1.011E-06 1 8.85E-03 ACTRAINE TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR 0 1 1.00E+00 0 .88 8.76E-01 SWAASWPIBR FLAG- Service Water Pump PSWOt B Is In Operation SWCVC04602 Service Water Pump PSW01B Discharge Check Valve 4802 Fais To Ciose On 5.84E-04 .58 5.79E-01 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 05E 1 5.84E-04

2. 0-4 2.05E-04 110 TIOOOOSW Total Loss of Service Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 1 1.00E+00 5.36E-10 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR 05E0. 1 1.00E+00 SWAASWP1DR 88 8.76E-01 FLAG - Service Water Pump PSWOID Is In Operation SWCVC04804 58 5.79E-01 Service Water Pump PSW01 D Discharge Check Valve 4604 Fais To Close On 5.84E-04 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 1 5.84E-04
2. 04 2.05E-04 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT ItI TIOOO0SW 1 1.00E+00 Total Loss of Service Water 0. 1 ACB2FIBS18 Local Fault on 480 VAC Bus It 1.00E+00 5.36E-10 1.01E-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR 0. 1 1.00E+00 SWAASWPIAR 88 8.76E-01 FLAG- Service Water Pump PSW01A Is In Operation SWCVC0460I Service Water Pump PSW01A Discharge Check Valve 4601 Fails To Close On 5.84E-04 58 5.79E-01 SWMMSWPORT FAILURES OF SW PUMP D TO RUN 05E 1 5.84E-04
2. D4 2.05E-04 112 TI00OSW Total Loss of Service Water ACB2FIBS18 Local Faunt on 480 VAC Bus 18 1 1.00E+00 8.28E-10 1.01E-06 0.:1 8.85E-03 ACTRAINA TAG - Failure of AC Train A
0. 1 1.00E+00 PCF PLANT CAPACITY FACTOR SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0-588 8.78E-01 SWCVC04603 Servce Water Pump PSW01C Discharge Check Valve 4603 Fails To Close On &84E-04 s8 5.79E-01 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 0.2 1 5.84E-04 2.1 04 2.02E-04 113 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR 0.8 1 1.00E+00 5.228-10 SWAASWPIAR FLAG- Service Water Pump PSW01A Is In Operation 0.188 0.12 8.76E-01 SWAASWPICR FLAG- Service Water Pump PSWOIC Is In Operation 0.558 5.79E-01 SWMM0SWPDS FAILURES OF SW PUMP D TO START 58 5.79E-01 3.228E-033 SWTMPUMP1B 3.28E-03 SW Pump B in maintenance UVREKI829A 0.105 4.55E-02 RELAY 29-A IN BUS 1 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 UVREKI129C RELAY 29-C IN BUS 10 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 0.11 3.45E-03 114 TI0000SW Total Loss of Service Water PCF 1 1.00E+00 5.22E-10 PLANT CAPACITY FACTOR 0.888 SWAASWPIAR 8.76E-01 FLAG - Service Water Pump PSW01A Is In Operation 0.5 SWAASWPiCR FLAG- Service Water Pump PSWOIC Is In Operation 58 5.79E-01 0.S58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 5.79E-01 3.2 8E-C0 SWTMPUMPIB SW Pump B in maintenance 3.28E-03 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER28.94E-07 0.005 4.55E-02 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 115 TIOOOSW Total Loss of Service Water 1 3.45E-03 1 1.000+00 5.22E-10

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERM.94E-07 1 3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2118 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 116 710000SW Total Loss of Service Water 1 1.00Ee00 0.22E-j1O PCF PLANT CAPACITY FACTOR 0.08 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C is In Operation 0.58 0.79E-01 SWMM0SWPDS FAILURES OF SW PUMP D TO START 3.21.E-03 3.28E1-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1 3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 117 T10000SW Total Loss of Service Water 1 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.70E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.281E-03 3.280-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 I 3.45E003 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/I 8 TRANSFERS TO DE-ENERGIZE3.94E-07 I 3.45E-03 118 TI000OSW Total Loss of Service Water 1 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 S.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOI C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28 E-03 3.28E-03 SWTMPUMPIS SW Pump B In maintenance 0.05 4.55E-02 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 1 3.45E-03 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 119 TI0000SW Total Loss of Service Water 1 1.00E+00 0.22E-10 PCF PLANT CAPACITY FACTOR 0.08 8.76E-01 SWAASWP1AR FLAG - Servie Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.08 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28 E-03 3.28E003 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.45E-03 UVREKO829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 120 T10000SW Total Loss of Service Water 1 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.08 5.79E-01 SWMMOSWPoDS FAILURES OF SW PUMP D TO START 3.28 E-03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1 3.451-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 121 T10000SW Total Loss of Service Water 1 1.002+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP 0 TO START 3.281E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance UVREKIO29B 0.05 4.550-02 RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER3.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 1 3.45E-03 122 TI0000SW Total Loss of Service Water I 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START

.28 E-03 3.20E-03 SWTMPUMP1S SW Pump B in maintenance 0.05 4.55E-02 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVRERI7ED8 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 123 TI0000SW Total Loss of Service Water 1 1.00E+00 0.22E-10 PCF PLANT CAPACITY FACTOR 1.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA in In Operation 0.08 0.79E-01 SWAASWPtCR FLAG - Service Water Pump PSWOIC Is In Operation 1.58 0.20 6.79E-01 SWMM0SWPDS FAILURES OF SW PUMP D TO START 3 E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance UVREKI828C 1.05 4.55E-02 RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 124 TI0000SW Total Loss of Service Water 1 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 00.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWPICR 0.58 5.79E-01 FLAG - Service Water Pump PSW01C Is In Operation

.285 058 5.79E-01 SWMMOSWPDS SWTMPUMPI B FAILURES OF SW PUMP D TO START SW Pump B in maintenance 3

0"-03 3.28E-03 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 '.05 4.55E-02 UVRERI2718 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27I18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 125 110000SW Total Loss of Service Water 0 1 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR SWAASWP1AR 0 .88 8.78E-01 FLAG - Service Water Pump PSWO1A Is In Operation

.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP 0 TO START .28E s.8 5.79E-01 SWTMPUMP1B SW Pump B in maintenance 3.

0."-03 3.28E-03 UVREKI829C .05 4.55E-02 RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7D18 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO DE-ENERGIZED 3.94E-07

0. 1 3.45E-03 126 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR 0. 1 1.00E+00 5.22E-10 SWAASWPIAR 0..88 8.78E-01 FLAG - Service Water Pump P-WOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0..58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 28 58 0.79E-01 3.

SWTMPUMPIB SW Pump B in maintenance 0.03 3.28E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 05 4.55E-02 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 1 3.45E-03 3.94E-07 0., 1 127 TI0000SW 3.45E-03 Total Loss of Service Water PCF PLANT CAPACITY FACTOR 0. 1 1.00E+00 5.22E-10 SWAASWPIAR FLAG - Service Water Pump PSW1A Is In Operation 0.88 8.76E-01 SWAASWP1CR 58 8.79E-01 FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START 28Eo08 5.70E-01 3J 03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.1 UVREKI829D 05 4.55E-02 RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 0.5 1 128 TI0000SW 3.45E-03 Total Loss of Service Water 28E-0 PCF 0.8 1 1.00E+00 5.22E-10 PLANT CAPACITY FACTOR 0.0 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.588 8.78E-01 SWAASWPICR 58 5.79E-01 FLAG - Service Water Pump PWOiC Is In Operation SWMMOSWPDS 58 0.790E-01 FAILURES OF SW PUMP D TO START 3.

SWTMPUMPI B 33 3.28E-03 SW Pump B in maintenance 0.805 UVREKI829D RELAY 29-0 IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 4.55E-02 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27DI18 TRANSFERS TO DEO-ENERGIZED3.94E-07 1 3.451-03 129 TI0000SW Total Loss of Service Water 0.5 1 3.45E-03 PCF 1 1.00E+00 5.22E-10 PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 88 8.76E-01 58 8.79E-01

SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.29E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 130 TI0000SW Total Loss of Service Water 1 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWMlA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWYMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.552-02 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/15 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 131 TI0000SW Total Loss of Service Water 1 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.o8 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 UVREKIBX28 BUS 15 UNDERVOLTAGE RELAY 27BX2115 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27DI18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 132 TI0000SW Total Loss of Service Water I 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79Eo01 SWAASWP1CR FLAG - Service Water Pump PSW0IC Is In Operation D.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIB SW Pump B inmaintenance 0.05 4.55E-02 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B1 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 133 TI0000SW Total Loss of Service Water 1 1.00E+00 6.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 328E-03 3.28E-03 SWTMPUMPI B SW Pump B in maintenance 0.05 UVREKIX218 4.55E-02 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BDs BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 134 TIO000SW Total Loss of Service Water I 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.282-03 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 UVRERG2718 BUS 18 UNDERVOLTAGE RELAY 27/11 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/t8 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 135 TIQ0OOSW Total Loss of Service Water 1 1.002+00 5.221-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW0h1C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BDS BUS 18 UNDERVOLTAGE RELAY 27D/Bs18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 136 TI0000SW Total Loss of Service Water 1 1.002+00 5.221-10 PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR 8.72E-01 FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 UVRERI7B1$ 4.55E-02 BUS 18 UNDERVOLTAGE RELAY 27B118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 UVRERI7D18 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27D/I18TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 137 TI0000SW Total Loss of Service Water I 1.00E+00 5.22E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 SWAASWP1CR 5.79E-01 FLAG - Service Water Pump PSWO1C Is In Operation 0.58 SWMMOSWPDS 5.79E-01 FAILURES OF SW PUMP D TO START 3.28E-03 SWTMPUMP1B 3.28E-03 SW Pump B in maintenance 0.05 UVRERI7BD8 4.552-02 BUS 18 UNDERVOLTAGE RELAY 27018/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 UVRERI7DI8 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27DI18 TRANSFERS TO DE-ENERGIZED 3.94Eo07 1 3.45E-03 138 TIO000SW Total Loss of Service Water I ACB2FIBS17 1.00E+00 5.05E-10 Local Fault on 480 VAC Bus 17 1.01E-06 1 ACCBR1829A AC BREAKER BUS18/29A TRANSFERS OPEN 8.85E-03 1.33E-06 24 3.19E-05 ACTRAINB TAG - Failure of AC Train B 1 DGAAINTAKE 1.002+00 FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF 1.23E-01 PLANT CAPACITY FACTOR 0.88 SWAZINTAKE 8.76E-01 Assumption that Lake Temperature Is Cold Enough to Cause Frazil Iceoand Loss of SW (3 0.02 1.86E-02 139 T10000SW Total Loss of Service Water I ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.00E+00 5.05E-10 1.0iE-08 1 ACCERI 829B AC BREAKER BUS18129B TRANSFERS OPEN 8.85E-03 1.33E-06 24 ACTRAINB TAG - Failure of AC Train B 3.19E-05 1 1.002+00 DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 1.23E-01 0.88 8.76E-01 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Casse Frazl ice and Loss of SW (3 0.02 140 TI0000SW Total Loss of Service Water 1.66E-02 1 1.00E+00 5.05E-10 ACB2FIBS18 Local Fault on 480 VAC Bus 1 1.01 E-08 1 8.85E-03 ACCBR1727A AC BREAKER BUS17/27A TRANSFERS OPEN 1.33E-06 24 3.19E-05 ACTRAINA TAG - Failure of AC Train A I DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 1.00E+00 0.12 1.23E-01 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (3 8.78E-01 0.02 141 TI0000SW Total Loss of Service Water 1.66E-02 1 1.001200 5.05-E10 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1 8.85E-03 ACCBR1727B AC BREAKER BUS17/27B TRANSFERS OPEN 1.33E-08 24 3.1 9E-05 ACTRAINA TAG - Fatlure of AC Train A I DGAAINTAKE FLAG - MINIMUMOUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 1.00E+00 0.12 1.23E-01 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (3 0.02 1.86E-02 142 TIODOOSW Total Loss of Service Water I PCF PLANT CAPACITY FACTOR 1.00E+00 4.422-10 0.88 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 8.76E-01 0.58 5.79E-01 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 2.05E-04 0.02 SWPPJIHDRB SERVICE WATER HEADER rB"PIPING RUPTURE 2.47E-02 8.53E-07 1 SWTMPUMP1C SW Pump C in maintenance 4.94E-03 0.04 3.58E-02 143 TI0000SW Total Loss of Service Water I 1.00E+00 4.42E-10 POP PLANT CAPACITY FACTOR 0.88 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 8.78E-01 0.58 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 5.79E-01 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 2.05E-04 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER A PIPING RUPTURE 5.53E-07 1 SWTMPUMPIC SW Pump C in maintenance 4.84E-03 0.04 3.50E-02 144 T10000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 8.782-01 0.58 5.79E-01

SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMOSWPAS FAILURES OF SW PUMP A TO START 328E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 145 T10000SW Total Loss of Service Water I 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 6.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1 3.45E-03 UVREKt729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 146 Tt0000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.792-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 147 TI0000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-91 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 148 TIOO0OSW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.22E-03 3.28E-03 SWTMPUMP1C SW"Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1 3.45E-03 UVRERt7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/8/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 149 TI000OSW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 .79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQO.94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 10 TI0000SW Total Loss of Service Water 1 1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW012 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWThMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG0.94E-07 1 3.45E-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.04E-07 1 3.45E-03 151 T10000SW Total Loss ofServiceWater 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.792-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER/8.94E-07 I 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 152 T10000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGE.94E-07 I 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 153 T10000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.as 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOlD Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERLN94E-07 I 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 154 TI0000SW Total Loss of Service Water 1 1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.w8 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.281-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.58E-02 UVREKI1729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 155 T10000SW Total Loss of Service Water I 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 156 T10000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG -Service Water Pump PSW1lD Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.562-02 UVREKI729C RELAY29-C IN BUS 17 UNDERVOLTAGE CIRCUITTRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.452-03 157 TI0000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.282-03 SWTMPUMPIC SW Pump C in maintenance 0.94 3.06E-02 UVREKI729D RELAY29-D IN BUS 17 UNDERVOLTAGE CIRCUITTRANSFERS TO ENER 3.94E-07 I 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 158 Ti0000mW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.28E-03

SWTMPUMP1C SW Pump C Inmaintenance 0.04 3.56E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 159 TIOO0OSW Tolal Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78G-01 SWAASWPIBR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 160 T10000SW Total Loss of Service Water I 1.00E+00 4.091-10 PCF PLANT CAPACITY FACTOR 0.88 8.76B-OI SWAASWP1BR FLAG - Service Water Pump PSWoB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C In mainlenance 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 161 1I0000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.285-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.9425-07 1 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 162 T10000SW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.28E-03 SWTMPUMP1C SW Pump C inmaintenance 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO D0-ENERGIZED 3.94E-07 1 3.45E-03 163 TI0OOOSW Total Loss of Service Water 1 1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG- Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.582-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO D0-ENERGIZED 3.94E-07 1 3.45E-03 164 T10000SW Total Loss of Service Water 1 1.0012+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is Io Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.58E-02 UVREKIlX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 165 TI0000SW Total Loss of Service Water I 1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1S Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 156 TI0000SW Total Loss of Service Water 1 1.00+E00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWOI0D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.282-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO D2-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.04E-07 1 3.45E-03 167 r0ooosW Total Loss of Service Water 1 1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTrMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.942-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.452-03 168 TIOOOOSW Total Loss of Service Water 1 1.00E+00 4.0gE-10 PCF PLANT CAPACITY FACTOR 0.88 8.762-01 SWAASWPI6R FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.792-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 SWMlMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7SD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 169 TIOOOOSW Total Loss of Service Water 1 1.0012+00 4.069-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.289-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWTMPUMPID SW Pump 0 in maintenance 7.15E-03 7.15E-03 170 TI000OSW Total Loss of Service Water 1 1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ3.942-07 1 3.45E-03 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 171 710000SW Total Loss of Service Water 1 1.00E+00 3.95E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOiA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER3.94E-07 1 3.45E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.942-07 1 3.452-03 172 T10000SW Total Loss of Service Water 1 1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E207 1 3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27X2)218 TRANSFERS TO ENERGIZED 3.04E-07 1 3.45E-03 173 T1000OSW Total Loss of Service Water 1 1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

SWAASWP1AR FLAG - SerAice Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASNPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 14E-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 .14 1 3.45E-03 UVRERI7B1 8 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 174 TI0000SW Total Loss of Service Water 1 1.00E-00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWP1ICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 141-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERCM.94E-07 .1 I 3.45E-03 UVRER17BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 I 3.45E-03 175 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW0lA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 4E-04 1.14E-04 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGM.94E-07 1.1 1 3.45E-03 UVREKIB29C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 176 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.78E-01 SWAASWPICR FLAG - Service Water Pump PSWIC Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.1 4E-04 1.14E-04 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAG E CIRCUIT TRANSFERS TO ENERG8.94E-07 1 3.45E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 177 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.768-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.798-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 I 3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 178 T0000SW Total Loss of Service Water 1 1.00E+00 3.99E810 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWE1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 4E-04 1.14E-04 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG/.94E-07 1.14 1 3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/t8 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.48E-03 179 TIDOOOSW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.78E-01 SWAASWPICR FLAG- Service Water Pump PSW01C Is In Operation 0.58 5.78E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start I1.14 41-04 1.14E-04 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG(.94E-07 I 3.45E-03 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 180 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Faiure Of Service Water Pumps To Start I1.144E-04 1.14E-04 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2J18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.48E-03 181 TIOO0OSW Total Loss of Service Water 1 1.00E+00 3.98E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPI1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 8.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 8.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1 E-04 1.14E-04 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 .14 1 3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 182 T10000SW Total Loss of Service Water 1 1.008+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW1A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Stant .14lE-04 UVREKI1829C 1.14E-04 RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7DI8 1 3.45E-03 BUS 18 UNCERVOLTAGE RELAY 27D/1 8 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 183 TI10000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI828D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 14E-04 1.14E-04 UVREKIX218 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 184 TI0000SW Total Loss of Service Water 1 1.00E+O0 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWIC Is In Operation 0.58 8.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 141E-04 UVREKI829D 1.14E-04 RELAY 29-C IN BUS 18 UNDiERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2718 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 185 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWIC Is In Operation SWCCPUMPSS 0.58 5.79E-01 Common Cause Failure Of Service Water Pumps To Start 1. 141E-04 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1.14E-04 UVRERI7DI8 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27D/a8 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 188 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR SWAASWPIAR 0.88 8.76E-01 FLAG - Service Water Pump PSW01A Is In Operation 0.58 8.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWCCPUMPSS 0.58 8.79E-01 Common Cause Falcre Of Service Water Pumps To Stan 1.114E.

UVREKIBX28 E-04 1.148-04 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 UVREKIX218 I 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 27X2118 TRANSFERS TO ENERGIZED 3.94E-07 1 3.458E-03 187 T10000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 1.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.58 5.79E-01 1.114 '-04 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX218 TRANSFERS TO ENERGIZED 3.94E-07 1.14E-04 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/1t TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 1 3.45E-03 188 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR SWAASWPIAR '.88 8.76E-01 FLAG - Service Water Pump PSWUIA Is In Operation SWAASWPICR .58 5.79E-01 FLAG - Service Water Pump PSW01C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 40 .58 5.79E-01 i.t UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2118 TRANSFERS TO ENERGIZED 3.94E-07 -04 1.148-04 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.46E-03 0

189 TI000SW 1 3.45E-03 Total Loss of Service Water PCF PLANT CAPACITY FACTOR 0 1 1.00E+00 3.99E-10 SWAASWPIAR 0.88 8.78E-01 FLAG - Service Water Pump PSWOIA Is In Operation

.588 .79E-01 SWAASWPICR FLAG - Service Water Pump PSWG1C Is In Operation

.58 5.79E-01

SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.142-04 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 271h18 TRANSFERS TO DE-ENERGIZED 3.94E.07 I 3.4SE-03 190 TI0000SW Total Loas of Service Water I 1.00E200 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW0IC Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 1.1 4E-04 1.14E-04 3.94E-07 1 3.45E-03 UVRERr7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.452-03 191 T10000SW Total Loss of Service Water 1 1.00E+00 3.90E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is tn Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 4E-04 1.14E-04 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1.1 1 3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 192 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWO0A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Servioe Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.1 4E-04 1.14E-04 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D8/W18TRANSFERS TO DE-ENERGIZE3.94E-07 I 3.45E-03 193 TI0OOOSW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Faflure Of Service Water Pumps To Start 1.1442-04 1.14E-04 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 194 Tf0000SW Total Loss of Service Water 1 1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Faiure Of Service Water Pumps To Start UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27DM/18 TRANSFERS TO DE-ENERGIZE3.94E-07 .144E-04 1.14E-04 1 3.45E-03 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 2713/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 195 TI0000SW Total Loss of Service Water 1 1.00E+00 3.989E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.08 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14 1E-04 1.14E-04 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER03.94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I 3.45E-03 196 110000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start E-04 1.14E-04 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ8.94E-07 1.14 1 3.45E-03 UVREKI729D RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 197 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWS18 Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14 2E-04 1.14E-04 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG2.94E-07 1 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY27BX2/17TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 198 TIOO0SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1 B Is In Operation 0.58 5.792-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGS.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E-03 199 T10000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWF1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.08 5.79E-01 SWCCPUMPSS Common Cause Failure Of Serwice Water Pumps To Start UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 .14 E-04 1.14E-04 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/8/17 TRANSFERS TO DE-ENERGIZE3.94E-07 I 3.45E-03 200 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.88 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start .14EE-04 1.14E-04 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 201 T10000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.89 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1 .14EE-04 1.14E-04 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGM.94E-07 1 3.45E-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 202 T10000SW Total Loss of Service Water 1 1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1 BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start .141E-04 1.14E-04 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQB.94E-07 1 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 203 TISOOOSW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWDIB Is Ie Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start .149.E104 1.14E-04 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGt.94E-07 1 3.45E-03 UVRERI7BI 7 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 204 T10000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW9018 Is In Operation 1.08 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWS1D Is In Operation 1.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 142 '-04 1.14E-04 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQM.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 205 T10000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR SWAASWPIR .88 8.76E-01 FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation

'.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1. 142 UVREKI729C --04 1.14E-04 RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03

UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27)(21 17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 206 TI0000SW Total Loss of Service Water 1 1.00E-00 3.99E-10 PC, PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Servlce Water Pump PSWOI D Ison Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRER12717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 207 Tt0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is Io Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27DI17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 208 T10000SW Total Loss of Service Water I 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 209 TI0000SW Total Loss of Service Water 1 1.00E100 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW1lD Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 210 TI0000SW Total Loss of Service Water 1 1.00E+00 3.9ME-10 PCF PLANT CAPACITY FACTOR 0.88 &76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01 B Is In Operatlon 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.141-04 1.14E-04 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DO-ENERGIZED 3.94E-07 1 3.45E-03 211 TI0000SW Total Loss of Service Water 1 1.00E+00 3189E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 278X2/17 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 212 T10000SW Total Loss of Service Water 1 1.008E+ 3.18E-10 POF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1 D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 213 T100OOSW Total Loss of Service Water I 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Stan 1.14E-04 1.14E-04 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 214 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSWM1D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKIX217 1.14E-04 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 UVRERI7817 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 215 T10000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is tn Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKIX217 1.14E-04 BUS 17 UNDERVOLTAGE RELAY 27XV217 TRANSFERS TO ENERGIZED 3.94E-07 1 UVRERI7BD7 3.45E.03 BUS 17 UNDERVOLTAGE RELAY 27D/B17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 218 TIODOOSW Total Loss of Service Water I 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSW(1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump POW01D Is tn Operation 0.58 SWCCPUMPSS 5.79E-01 Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 UVRERI7B17 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 217 TI0000SW Total Loss of Service Water 1 1.00E+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP11BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 SWAASWP1 DR 5.791-01 FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCCPUMPSS 5.79E-01 Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVRERI2717 1.14E-04 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 UVRERI7BD7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 218 TI0000SW Total Loss of Service Water I PCF 1.00E+00 3199E-10 PLANT CAPACITY FACTOR 0.88 SWAASWPIBR 8.76E-01 FLAG - Service Water Pump PSW018 Is In Operation 0.58 SWAASWPIDR 5.79E-01 FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVRERI27D7 1.14E-04 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 UVRERI7E17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 1 3.45E.03 219 TI0000SW Total Loss of Service Water I PCF 1.00E+00 31991-10 PLANT CAPACITY FACTOR 0.88 SWAASWPI BR 8.76E-01 FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWID Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 5.79E-01 1.14E-04 UVRERI27D7 1.14E-04 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 894E-07 1 UVRERI7BD7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27D08117 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 220 TI0000SW Total Loss of Service Water 1 PCF 1.00E+00 3.89E-10 PLANT CAPACITY FACTOR 0.88 SWAASWP1BR 8.76E-01 FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 5.79E-01 0.02 2.47E-02 SWMMSWPCRT FAILURES OF SI PUMP C TO RUN 2.05E-04 2.05E-04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 SWTMPUMP1A 4.84E-03 SW Pump A In maintenance 0.03 221 T10000SW 3.13E-02 Total Loss of Service Water 1 1.00E+00 3.89E-10 PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1DR 8.76E-01 FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWMMSWPCRT 5.79E-01 FAILURES OF SW PUMP C TO RUN 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 2.05E-04 0.02 SWPPJIHDRA 2.47E-02 SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 SWTMPUMPIA SW Pump A In mainlenance 4.84E-03 0.03 3.13E-02 222 T10000SW Total Loss of Service Water 1 1.00E+00 3.59E-10

PCF PLANT CAPACITY FACTOR 0.88 &78E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQO.94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 223 T10000SW Total Loss of Service Water I 1.00E800 3.59E-iA PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1 BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWFP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMM0SWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPtA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ2,94E-07 I 3.45E-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 224 TI0000SW Total Loss of Service Water I 1.O0E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWE 1D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI1729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 I 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 225 TI0000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-Ol SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERC3.94E-07 1 3.48E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 226 Ti0000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW0t D Is In Operation 0.58 5.79E-81 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG2.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D8/117 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 227 TI0000SW Total Loss of Service Water 1 1.008+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0,58 5.7E-E01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3,94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 228 TI8000SW Total Loss of Service Water 1 1.00E+00 3.598-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.138-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.458-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 229 TI0000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERCE.94E-07 1 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E807 1 3.45E-03 230 TIOSOCSW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 231 TI0000SW Total Loss of Service Water 1 1.008+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPiBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW010 Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E803 232 T10000SW Total Loss of Service Water 1 1.00E+00 3.598-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1 D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SVVWIPUMPIA SWPump A in maintenance 0.03 3.13E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X3217 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 233 TI000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SIN PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E.03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 234 TI0000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.78E801 SWAASWP1DR FLAG - Service Water Pump PSWOtD Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.84E-07 1 3.45E-03 235 TI0000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BR FLAG - Service Water Pump PSW015 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.798-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPlA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREIIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 236 T10000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWS1B Is In Operation 0.58 5.79E-01

SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-1 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWIrMPUMPlA SW PumpA in maintenance 0.03 3.13E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRER12717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 237 T10000SW Total Loss of Service Water I 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 238 T10000SW Total Loss of Service Water I 1.002E00 3.59E.10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Isnt Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKIB217 BUS 17UNDERVOLTAGE RELAY27BX2I17TRANSFERSTOENERGIZED 3.94E-07 1 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 239 TI0000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 6.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPOS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 240 T10000SW Total Loss of Service Water 1 1.00E200 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMMSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 241 T10000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SWPump A in maintenance 0.03 3.13E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7817 BUS 17 UNDERVOLTAGE RELAY 272/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 242 TI000OSW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMSSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI78D7 BUS 17 UNDERVOLTAGE RELAY 27D/0/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 243 TI0000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0o58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 272/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 244 T10000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANTCAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/A117 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 245 TI0OOOSW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.78E-01 SWAASWPIDR FLAG - Service Water Pump PSW010 Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 246 T10000SW Total Loss of Service Water 1 1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWIB Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW010 Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27DBI 7 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 247 TI0000SW Total Loss of Service Water 1 1.00E+00 3.24E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 ACTRAINB TAG - Faium of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPART FAILURES OF SERV1CE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 248 T10000SW Total Loss of Service Water I 1.00E+00 3.202-10 ACB2FIBS1B Local Fault on 480 VAC Bus 18 1.012-06 1 8.85E-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 249 TI0000SW Total Loss of Service Water 1 1.002+00 2.58E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVtCE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMP1D SIN Pump D in maintenance 7.15E-03 7.15E-03 250 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Falure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1 3.45E-03 IVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 251 710000SW Total Loss of Service Water 1 1.00E+00 2.64E-10

ACB2FTBSI 7 Local Fault on 480 VAC Bus 17 1.0112-06 72 7.27E-05 ACTRAINB TAG - Fauure of AC Train B 1 1.0E000 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW0IC Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1 3.45E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 252 TI0000SW Total Loss of Service Water 1 1.00E+00 2.542-10 ACE2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG1.94E-07 1 3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 253 TIQOCOSW Total Loss of Service Water 1 1.00E200 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.002E00 PCF PLANT CAPACITY FACTOR 0.88 8.79E-01 SWAASWPIAR FLAG - Service Water Pump PSWD1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 1 3.45E-03 UVRERI7B18 BUS 19 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 254 TIOOOSW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.79E-01 SWAASWPIAR FLAG - Service Water Pump PSWD1A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGa.94E-07 1 3.45E-03 UVRERI7BD9 BUS 18 UNDERVOLTAGE RELAY 270/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 255 T10000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 &76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGE.94E207 1 3.45E-03 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 256 T10000SW Total Loss of Service Water 1 1.02E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E201 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGa.94E-07 I 3.45E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 257 T10000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1 3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 258 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Fuilure of AC Train B 1 1.00E+00 PCF PLANTCAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.792-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQE.94E-07 1 3.45E-03 UVRERI7BI8 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 259 TIOOOSSW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 489 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWS1C Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQM.94E-07 1 3.45E-03 UVRERI7BDS BUS 18 UNDERVOLTAGE RELAY 27018/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 260 TIOOOOSW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 489 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.79E201 SWAASWP1AR FLAG - Service Water Pump pSWO1A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY27X2118 TRANSFERSTO ENERGIZED 3.94E-07 1 3.45E-03 261 TIOOOOSW Total Loss of Service Water 1 1.001+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.08E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 262 T10000SW Total Loss of Service Water I 1.00E+00 2.54E.10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 263 T10000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.012E-0 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C is in Operation 0.58 5.79E-01 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 264 T10000SW Total Loss of Service Water 1 1.00E+00 2.64E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.002+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE0ENERGIZED 3.94E-07 1 3.45E-03 265 TIO0SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00

PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI71318 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 266 TI00OOSW Total Loss of Service Water 1 1.00+200 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failurm of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump P-W01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 287 TI0000SW Total Loss of Service Water I 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train 8 1 1.00E+80 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.88 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 278X2118 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 268 710000SW Total Loss of Service Water I 1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27D1/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 269 TI0000SW Total Loss of Service Water I 1.00E+00 2.54E-10 ACB2FTES17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINS TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 270 T10000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.001200 PCF PLANT CAPACITY FACTOR 0.88 8.788-01 SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D0B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 271 TI000OSW Total Loss of Service Water I 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.78E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BI8 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 272 TI0000SW Total Loss of Service Water I 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault an 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failure of AC Train 5 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 273 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure ofAC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E803 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/I8 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.48E-03 274 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWSIA Is In Operation 0.58 3.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/8118 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 275 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E.10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Falure of AC Train A 1 1.002E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW0lD Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 1 3.45E-03 UVREKI7290 RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.458E-03 278 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 I 3.45E-03 UVREKI17290 RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 277 TISOSOSW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus lB 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOI B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 1 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 278 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27817 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.45E803 279 TIOO00SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSWO18 Is In Operation 0.58 5.79E-01

SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 I 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B117 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 280 TI000OSW Total Loss of Service Water 1 1.00E-00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01 B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWI1D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 281 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS1B Local Fault on 490 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1 B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1 3.45E-03 UVREKI1729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 282 TI0000SW Total Loss of Service Water I 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPI BR FLAG - Service Water Pump PSWOI B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 283 TI0000SW Total Loss of Service Water I 1.00E+00 2.54E-10 AC82FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO0D Is In Operation 0.58 5.79E-01 UVREKI7295 RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 284 TI0000SW Total Loss of Service Water I 1.00E+00 2.54E.10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 727E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D0/B17 TRANSFERS TO DE-ENERGIZE3.94E-07 I 3.45E-03 285 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E010 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.001+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B I In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 2712/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 288 TIC0OSW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.790E01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DEO-ENERGIZED 3.94E-07 1 3.45E-03 287 T10000SW Total Loss of Service Water I 1.900E00 2.540-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW801 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D1l17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 288 TI000SW Total Loss of Service Water I 1.00E0+0 2.54E-10 ACB2FTESI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 579E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X217 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 289 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 UVREKI728D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 290 TI0000SW Total Loss of Service Water I 1.00E+00 2.64E.10 ACB2FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 &76E-01 SWAASWP1BR FLAG - Service Water Pump PS601B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 291 TI0000SW Total Loss of Service Water 1 1.00E+00 2.54E-10 ACB2FTBSI Local Fault on 480 VAC Bus 13 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANTCAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E001 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 292 TI0000SW Total Loss of Service Water 1 1.00.E00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus I8 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1 BR FLAG - Service Water Pump PSWB01BIn to Operation 0.58 5.79E-01 SWAASWPIDR FLAG- Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 293 T10000SW Total Loss of Service Water I 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.010-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 6.78E-01 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03

UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 294 TI0000SW Total Loss of Servioe Water 1 3.45E-03 ACB2FTBS18 I 1.00E+00 2.54E-10 Local Fault on 480 VAC Bus 18 ACTRAINA 1.01E-06 72 7.27E-05 TAG - Failure of AC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWAASWPIBR 0.88 8.76E-01 FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSWO1D Is In Operation UVREKIX217 0.58 5.79E-01 BUS 17 UNDERVOLTAGE RELAY27X2/17 TRANSFERS TO ENERGIZED 7 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 1 UNDERVOLTAGE RELAY 27B/17I*.ANSFERS TO DE-ENERGIZED 295 T10000SW 3.948-07 1 3.45E-03 Total Loss of Service Water 1 1.008200 2.54E-10 ACB2FTBS1B Local Fault on 480 VAC Bus 18 ACTRAINA 1.01E-00 72 7.27E-05 TAG - Failure of AC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWAASWPI8R 0.88 8.76E-01 FLAG - Service Water Pump PSWOIB Is In Operation SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSWO1D Is In Operation UVREKIX217 0.58 5.79E-01 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27018/17 TRANSFERS TO DE-ENERGIZE3.94E-07 298 TI0000SW Total Loss of Service Water 1 3.45E-OS ACB2FTBS18 1 1.00E-00 2.64E.10 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWAASWPI8R 0.88 8.76E-01 FLAG - Service Water Pump PSWO1B Is In Operation SWAASWP1DR 0.58 5.79E-01 FLAG - Service Water Pump PSW0ID Is In Operation UVRERI2717 0.58 5.79E-01 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 297 T10000SW 3.94E-07 1 3.45E-03 Total Loss of Service Water ACB2FTBSI8 1 1.0012.00 2.54E-10 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWAASWP1BR 0.88 8.768E-01 FLAG - Service Water Pump PSWOIB Is In Operation SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSW0lD Is In Operatioo UVRERI2717 0.58 5.79E-01 BUS 17 UNDERVOLTAGE RELAY27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D0B/I 7 TRANSFERS TO DE-ENERGIZE3.94E.07 298 TI0000SW Total Loss of Service Water 1 3.45E-03 1 1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 ACTRAINA 1.01E-06 72 7.27E-05 TAG - Failure of AC Train A PCF 1 1.00E+00 PLANT CAPACITY FACTOR SWAASWPIBR 0.88 8.768E-01 FLAG - Service Water Pump PSW01B is In Operation SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSW01D Is In Operation UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 0.58 5.79E-01 3.94E-07 1 3.45E-03 UVRERI7817 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 299 TIO0OOSW 3.94E-07 1 3.45E-03 Total Loss of Service Water ACB2FTBS18 1 1.00E+00 2.54E-10 Local Fault on 480 VAC Bus 18 1.01E-00 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR 1 1.00E+00 SWAASWP1BR 0.88 &76E-01 FLAG - Service Water Pump PSW001B Is In Operation SWAASWP1DR 0.58 5.79E-01 FLAG - Service Water Pump PSW01D Is In Operation UVRERI27D7 0.58 5.79E-01 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94 E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E.07 300 TI0000SW Total Loss of Service Water 1 3.45E-03 PCF 1 1.008+00 2.428-10 PLANT CAPACITY FACTOR SWAASWPI1R 0.68 8.70E-01 FLAG - Service Water Pump PS01B Is In Operation SWAASWP1DNR 0.88 5.78E-01 FLAG - Service Water Pump PSW01D Is Not In Operation SWMMSWPBRI 0.42 4.21E-01 FAILURES OF SW PUMP S TO RUN SWMMSWPCRT 0.02 2.47E-02 FAILURES OF SW PUMP C TO RUN SWTMPUMP1A 2.051-04 2.05E-04 SW Pump A in maintenance SWTMPUMPID 0.03 3.13E-02 SW Pump D in maintenance 301 TI00DOSW 7.15E-03 7.108-03 Total Loss of Service Water PCF 1 1888.00 2.38-10 PLANT CAPACITY FACTOR SWAASWPIANR 088 8.78E-01 FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CR 0.42 4.21E-01 FLAG - Service Water Pump PSWIC Is In Operation SWMMSWPBRT 0.58 5.79E-01 FAILURES OF SW PUMP S TO RUN SWMVMSWPCRI 2.02E-04 2.02E-04 FAILURES OF SW PUMP C TO RUN SWTMPUMPIA 0.02 2.47E-02 SW Pump A in maintenance SWTMPUMP1D 0.03 3.13E-02 SW Pump D in maintenance 302 TI0000SW 7.15E-03 7.15E-03 Total Loon of Service Water PCF 1 1.008+00 1.61E-10 PLANT CAPACITY FACTOR SWAASWPIBNR 0.88 8.76E-01 FLAG - Service Water Pump PSW081B Is Not In Operatioa SWAASWPIDR 0.42 4.21E-01 FLAG - Service Water Pump PSW0lD Is In Operation SWMMOSWPAS 0.58 5.79E-01 FAILURES OF SW PUMP A TO START SWMMSWPCRT 3.28E-03 3.28E-03 FAILURES OF SW PUMP C TO RUN SWMMSWPDRI 2.058-04 2.858-84 FAILURES OF SW PUMP D TO RUN

.082 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 303 TI0000SW Total Loos of Service Water 0.05 4.55E-02 PCF 1 1.00E-00 1.61E-t0 PLANT CAPACITY FACTOR SWAASWPIBNR 0.88 8.76E-01 FLAG - Service Water Pump PSWO1B Is Not In Operation SWAASWP1DR 0.42 4.21E-01 FLAG - Service Water Pump PSW601DIs In Operation SWMMOSWPCS 0.58 5.79E-01 FAILURES OF SW PUMP C TO START SWMIMSWPART 3.28E-03 3.28E-03 FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1B 0.02 2.47E-02 SW Pump B in maintenance 304 T100005W 0.05 4.55E-02 Total Loss of Service Water 1 1.00+00 1.388-to PCF PLANT CAPACITY FACTOR SWAASWPIDNR 0.88 8.78E-01 FLAG - Service Water Pump PSW01D Is Not In Operation SWMMOSWPAS 0.42 4.21E-01 FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1D SWIPump D In malatenance 305 TIOOOSW 7.15E-03 7.158-03 Total Loss of Service Water PCF 1 1.008+80 1.268-10 PLANT CAPACITY FACTOR SWAASWPIAR 0.88 .70 16E-01 FLAG - Service Water Pump PSW01A Is In Operation SWAASWP1CNR 0.88 5.79E-01 FLAG - Service Water Pump PSWOIC Is Not In Operation SWMMOSWPBS 0.42 4.21E-01 FAILURES OF SW PUMP B TO START SWMMtSWPARI 3.28E-03 3.28E-03 FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPDRT 0.02 2.47E-02 FAILURES OF SW PUMP D TO RUN SWTMPUMP1C 2.05E-04 2.058-04 SW Pump C in maintenance 306 T10000SW Total Loss of Service Water 0.84 3.568-02 PCF 1 1.001+00 1.248-10 PLANT CAPACITY FACTOR 0.88 8.768E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWPICNR 0.58 5.79E-01 FLAG - Service Water Pump PSWOIC Is Not Io Operation 0.42 4.21E-01 SWMM8SWPDS FAILURES OF SW PUMP D TO START SWMMSWPARI 3.28E-03 3.28E-03 FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPBRT 0.02 2.47E-02 FAILURES OF SW PUMP B TO RUN SWTMPUMPiC SW Pump C In maintenance 2.02E-04 2.02E-04 307 T10000SW 0.84 3.568-02 Total Loss of Service Water 1 1.00E+00 1.20E-18 PCF PLANT CAPACITY FACTOR SWAASWPIAR 8.88 6.760 1E FLAG - Service Water Pump PSW01A Is In Operation SWAASWPlCR 0.88 5.798E-01 FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPBS 0.58 5.79E-01 FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPCRI 0.02 2.47E-02 FAILURES OF SW PUMP C TO RUN SWMMSWPDRT 8.02 2.478-02 FAILURES OF SW PUMP D TO RUN 308 TI000OSW Total Loss of Service Water 2.085-04 2.058-04 PCF 1 1.00E+00 1.308-to PLANT CAPACITY FACTOR 0.88 8.76E-01

SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSM01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWMMSWPORI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 309 TI0000SW Total Loss of Service Water 1 1.00E+00 1.20E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW0I D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWMMSWPSRI FAILURES OF SW PUMP S TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 310 TI0000SW Total Loss of Service Water I 1.000+00 1.19E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.790E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMIMSWPBRT FAILURES OF SW PUMP S TO RUN 2.02E-04 2.02E-04 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 311 TIOOOOSW Total Loss of Service Water 1 1.00E+00 1.11E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 312 T10000SW Total Loss of Service Water 1 1.00E+00 1.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 313 TI0O0OSW Total Loss of Service Water 1 1.00E+00 0.80E+00 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 ACTRAINB TAG - Failure of AC Train B I 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-81 SWIMPUMPtA SW Pump A in maintenance 0.03 3.113E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 314 TI0000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.815-03 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWTMPUMP1S SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 315 TI0000SW Total Loss of Service Water 1.00E+00 0.000E00 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 721 727E-05 ACTRAINB TAG - Failure of AC Train B 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW0IA Is Not In Operation 0.42 4.21E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 318 TI0OOOSW Total Loss of Service Water I 1.00E+00 8.00E+00 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWPPJIHDRA SERVICE WATER HEAOER "A"PIPING RUPTURE 5.53E-07 1 4.84E-03 SWPPJIHDRB SERVICE WATER HEADER "B5PIPING RUPTURE 5.53E-07 1 4.84E-03 317 T10000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 ACB2FTES18 Local Fault on 480 VAC Bus 18 1.011-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPI BNR FLAG - Service Water Pump PSW01lB Is Not In Operation 0.42 4.21 E-01 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWTMPUMP1B SW Pump S in maintenance 0.05 4.55E-02 SWTMPUMPI D SW Pump D in maintenance 7.15E-03 7.15E-03 318 TIOE00SW Total Loss of Service Water I 1.00E+00 0.00E+00 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.278&O5 ACTRAINA TAG - Failure of AC Train A 1 1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWPPJIHORA SERVICE WATER HEADER A" PIPING RUPTURE 5.53E-07 I 4.84E-03 SWPPJIHDRB SERVICE WATER HEADER "S" PIPING RUPTURE 5.53E-07 1 4.84E-03 319 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 876E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.211-01 SWAASWP1CNR FLAG- Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failura Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWIMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 320 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSWO1A Is Not In Operation 0.42 4.21E-01 SWAASWP1CNR FLAG - Service Water Pump PSW0IC Is Not In Operation 0.42 4.21E-01 SWMMOSWPBS FAILURES OF SW PUMP S TO START 3.28E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 321 TI00QSW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWPICNR FLAG - Service Water Pump PSWO1 C Is Not In Operation 0.42 4.21E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 SWrMPUMPIA SW Pump A in maintenance 0.03 3.130-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.561-02 322 TI0000SW Total Loss of Service Water 1 1.00E+00 0.OOE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.131-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMPI D SW Pump D in maintenance 7.115E-03 7.15E-03 323 TI0000SW Total Loss of Service Water 1.008200 O.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSWE1A Is Not In Operation 0.42 4.21E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMM0SWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03

SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWTMPUMP1A SW Pump A in maiotenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 324 TIOOOOSW Total Loss of Service Water 1 1.OOE+n0 0.00+E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1S SW Pump S in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 325 TIOOOOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 326 T10000SW Total Loss of Service Water I 1.000+00 O.00E+00 PCF PLANT CAPACITY FACTOR 0.88 0.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWP1CNR FLAG - Ser.vce Water Pump PSWOIC Is Not In Operation 0.42 4.21E-01 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E.02 SWTMPUMP1e SW Pump S in maintenance 0.05 4.65E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.5612-02 327 710000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.70E-01 SWAASWPIANR FLAG - Service Water Pump PSWO1A Is Nat In Operntion 0.42 421E-01 SWAASWPICNR FLAG - Service Water Pump PSWOIC Is Not In Operation 0.42 4.21E-01 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIS SW Pump S in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 328 T000OSW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWP1CR FLAG - Service Water Pump PSWEIC Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SN Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 329 TI000SW Total Loss of Service Water 1 1.00E+00 0.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E.01 SWAASWP1CR FLAG - Service Water Pump PSW0IC Is In Operation 0.58 5.79E-01 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.051-04 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 330 T10000SW Total Loss of Service Water 1 1.00E+00 0.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Notun Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump S in maintenance 0.05 4.55E-02 SWTMPUMPI D SW Pump D in maintenance 7.15E-03 7.151-03 331 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER "B"PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump S in maintenance 0.05 4.55E-02 332 TIOOOSW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWMMSWPDRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWPPJIHDRS SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 333 TI0000SW Total Loss of Service Water I 1.000+00 0.0OE+00 PCF PLANT CAPACITY FACTOR 0.08 8.76E-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21 E-01 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 I 4.54E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump S in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 334 TI000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 SWAASWPICNR 5.79E-01 FLAG - Service Water Pump PSWOIC Is Not In Operation 0.42 4.21E-01 SWMMOSWPSS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWIMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 335 T10000SW Total Loss of Service Water 0 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CNR FLAG - Service Water Pump PSWMIC Is Nut In Operation 0.42 4.21E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWTMPUMPiC SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMPID SW Pump D in maintenance 7.151-03 7.15E-03 336 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 SWAASWP1CNR 5.79E-01 FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMP1 B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.150-03 337 TI7OOOSW Total Loss of Service Water 1 1.00E+00 0.000E00 PCF PLANT CAPACITY FACTOR SWAASWPIAR 0.88 8.76E-01 FLAG - Service Water Pump PSWOtA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMPIS SW Pump B in maintenance 0.02 2.47E-02 0.05 4.55E-02 SWrMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 338 TIOOSOW Total Loss of Service Water 0 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01

SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0.58 5.79E-01 SWTMPUMPID SW Pump D in maintenance 0.05 4.55E-02 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 7.115&-03 7.15E-03 TO ENERGaB4E-07 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 1 3.45E-03 TO ENER 3.94E-07 339 TIOOOOSW Total Loss of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.00E+00 8.00E+00 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.88 8.76E-01 SWAASWP1CR FLAG - Service Water Pump PSW01EC Is In Operation 0.58 5.79E-01 SWTMPUMPI B SW Pump B in maintenance 0.58 5.79E-01 SWTMPUMP1D SW Pump D in maintenance 0.05 4.55E-02 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 8E-03 7.15E-03 TO ENERGQ.94E-07 7.1 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 1 3.45E-03 TO ENER 3.94E-07 340 TIO0OOSW Total Loss of Service Water I 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.00E+00 0.00E+00 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.88 8.78E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWTMPUMP1B SW Pump B in maintenance 0.58 5.79E-01 SWTMPUMP1D SW Pump D in maintenance 0.05 4.55E-02 UVREKIB29A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 5E-03 7.15E-03 TO ENERG3.94E-07 7.1 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS 1 3.45E-03 TO ENERGIZED 3.94E-07 341 TIO000SW Total Loon of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.00E+00 0.00E+00 SWAASWPIAR FLAG - Service Water Pump PSW1iA Is In Operation 0.88 8.76E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWTIMPUMPIB SW Pump B in maintenance 0.58 5.79E-01 SWTMPUMPI D SW Pump D in maintenance 0.05 4.55E-02 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS E-03 7.151-03 TO ENERQ2.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 2713/18 TRANSFERS TO 1 3.45E-03 DE-ENERGIZED 3.94E-07 342 TIOOOOSW Total Loss of Service Water 1 3.45E-03 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.88 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01iC Is In Operation 0.58 5.79E-01 SWTMPUMP1B SW Pump B in maintenance 0.58 5.79E-01 SWTMPUMP1D SW Pump D in maintenance 7.15 0.05 4.55E-02 7

UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS E-03 7.15E-03 TO ENERCS.94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/S/18 TRANSFERS I 3.45E-03 TO DE-ENERGIZE .94E-07 343 TIOO0OSW Total Loss of Service Water 3 1 3.458E-03 PCF PLANT CAPACITY FACTOR 1 1.00E+00 0.001+00 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.88 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWTIMPUMPIB SW Pump B in maintenance 0.58 5.79E-01 SWTMPUMP1D SW Pump D in maintenance .15E 0.05 4.55E-02 UVREKI829B 7. E-03 RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 7.15E-03 TO ENERGB.94E-07 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS I 3.45E-03 TO ENER 3.94E-07 344 TI0000SW Total Loso of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.00E+00 0.00E+00 SWAASWPIAR FLAG - Service Water Pump PSW8/1A Is In Operation 0.88 8.761-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 8.79E-01 SWTMPUMP1B SN Pump B In maintenance 0.58 5.79E-01 SWTMPUMP1D SW Pump D in maintenance 15; 0.05 4.55E-02 UVREKI829B RELAY 29-B IN BUS lB UNDERVOLTAGE CIRCUIT TRANSFERS 7. ,-03 7.15E-03 TO ENERGQ.94E-07 UVREKI828D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 1 3.45E-03 TO ENER 3.94E-07 345 TIOOOOSW Total Loss of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.00E+00 0.00E+00 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.88 8.76E-01 198 0 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0'.58 5.79E-01 SWTMPUMPIB SW Pump B in maintenance .58 5.79E-01 SW/TMPUMPID SIN Pump D in maintenance '.05 4.55E-02 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 7: -03 7.15E-03 TO ENERGB.94E-07 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2118 TRANSFERS I 3.45E-03 TO ENERGIZED 3.94E-07 346 TI0000SW Total Loss of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.001+00 0.00E+00 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0. 8.8 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW1iC Is In Operation .58 0SE 5.798-01 SWTMPUMP1B SW Pump B in maintenance 0..58 5.79E-01 SWTMPUMPID SW Pump D in maintenance .05 4.55E-02 UVREKI829B 7.1 4D3 RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 7.15E-03 TO ENERG.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO 1 3.45E-03 DE-ENERGIZED 3.94E-07 347 TI0OOISW Total Loss of Service Water I 3.45E-03 PCF PLANT CAPACITY FACTOR 0. 1 1.00E+00 0.00E+00 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is in Operation 0. 88 8.78E-01 SWAASWPICR FLAG - Service Water Pump PSW0IC Is In Operation 58 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0. on 5.79E-01 SWTMPUMPID SW Pump D in maintenance 05 4.55E-02 7.1 58 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 33 7.15E-03 TO ENERG,94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS 1 3.45E-03 TO DE-ENERGIZE3.94E-07 348 TI00OESW Total Loss of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 0.8 1 1.00E+00 O.00E+00 SWAASWPIAR FLAG - Service Water Pump PSW1IA Is In Operation 0.1B8 8.76E-01 SWAASWPICR FLAG- Service Water Pump PSWSiC Is In Operation 0.1se 5.79E-01 SWTMPUMP1B SW Pump B in maintenance 0.C58 5.79E-01 SWTMPUMP1D SW Pump D in maintenance 05 4.55E-02 UVREKI829C 7.15 SB RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS O 7.15E-03 TO ENER 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27)(2/18 TRANSFERS TO 1 3.45E-03 ENERGIZED 3.94E-07 349 TIOOO0SW Total Loss of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 0. 1 1.00E+00 0.00E+00 0.0 SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation S 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01IC Is In Operation 0.5 5 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0.5 8 5.79E-01 SWTMPUMP1D SW Pump D in maintenance 7.15 E-0 5 4.55E-02 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 3 7.15E-03 UVRERI2718 TO ENER 3.94E-07 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO 1 3.45E-03 DE-ENERGIZED 3.94E-07 350 TI000SW Total Loss of Service Water 1 3.45E-03 D.51 PCF PLANT CAPACITY FACTOR 0.8 1 1.00E+00 0.00E+00 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.8 8 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C In In Operation 0.88 58.79E-01 SWTMPUMPIB SW Pump B in maintenance 8 5.79E-01 SWTMPUMP1D SW Pump D in maintenance 5 4.55E-02 UVREKI829C 7.15 RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 1 7.15E-03 TO ENER 3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO I 3.45E-03 D0-ENERGIZED 3.94E-07 351 TI0000SW Total Loss of Service Water S 3.45E-03 PCF PLANT CAPACITY FACTOR 1.00E+00 O.OOE+80 SWAASWPlAR FLAG - Service Water Pump PSW0IA Is In Operation 0.&88 8.78E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 1 0.58I 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0.08 5.79E-01 SWTMPUMPID SW Pump D in maintenance 4.55E-02 UVREIO829D 7.1 E-03 RELAY 29-DIN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS 7.15E-03 TO ENER 3.94E-07 0.58 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2J18 TRANSFERS TO 3.45E-03 ENERGIZED 3.94E-07 352 T1000SW Total Loss of Service Water 3.45E-03 PCF PLANT CAPACITY FACTOR 0.88 1.00E+80 0.00E+00 SWAASWPIAR FLAG - Service Water Pump PSWIA Is In Operation 8.76E-01 0

SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 5.79E-01 0

L58 5.79E-01

SWTMPUMPI B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1D SW Pump D in maintenance 7. ISE-03 7.15E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E.07 1 3.45E.03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 353 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWTMPUMP1B SW Pump B In maintenance 0.05 4.55E.02 SWTMPUMP1D SW Pump D in maintenance 5E-03 7.15E-03 UVREK1829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 7.1 I 3.45E-03 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 354 TI0000SW Total Loss of Service Water 1 1.008200 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E.01 SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E.01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPI D SW Pump D In maintenance 5E-03 7.158-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 7.1 1 3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27",2/18 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 355 T10000SW Total Loss of Service Water 1 1.00E+00 0.0012+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is in Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWThIPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 5E-03 7.15E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 7.1 I 3.45E-83 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 356 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00+E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E.01 SWAASWPlCR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWTMPUMP1B SW Pump B in maintenance 0.05 4.58E-02 SWTMPUMP1D SW Pump D in maintenance 5E-03 7.15E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 7.1.

1 3.45E-03 UVRERI7Dt8 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 I 3.458E-03 357 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance 7.15 5E-03 7.15E.03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E.07 1 3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 358 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance E-03 7.15E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 I 3.45E-03 359 T10000SW Total Loss of Service Water 1 1.008+00 0.00E+00 PCF PLANT CAPACITY FACTOR 7.15 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPID SW Pump D in maintenance UVRERI2718 E-03 7.15-E03 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7818 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 271/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 360 T10000SW Total Loss of Service Water 1 1.00E+00 0.008+00 PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWS1A Is In Operation ris 7.15 0.88 8.76E-01 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0.05 4.58E-02 SWTMPUMPID SW Pump D in maintenance 7 E-03 7.18-E03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7008 BUS 18 UNDERVOLTAGE RELAY 27D/B118 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 361 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 7.15E0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWSIC Is In Operation 0.58 5.79E-01 SWTMPUMPI SW Pump B in maintenance SWTMPUMPID 0.05 4.55E-02 SW Pump D In maintenance 7 UVRERI7B18 E-03 7.18E-03 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7D18 1 3.45E-03 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 382 TI0000SW I 3ASE-03 Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.70E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASuWPICR 0.58 5.79E-01 FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E801 SWTMPUMP18 SW Pump B in maintenance SWTMPUMP1D 0.05 4.55E-02 SW Pump D In maintenance 7..151i-03 UVRERIJBD8 7.15E-03 BUS 18 UNDERVOLTAGE RELAY 27D/8118 TRANSFERS TO DE-ENERGIZE3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.04E-07 1 3.45E-03 1 3.45E-03 363 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWPIAR 0.88 8.76E-01 FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVTCE WATER PUMP A TO RUN SWPPJIHDRB 1.02 2.47E-02 SERVICE WATER HEADER WB` PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMP1B SW Pump B in maintenance SWTMPUMPID 1.05 4.55E-02 SW Pump D In maintenance 7.158 -03 384 TI0000SW 7.158E-03 Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWPIBNR 1.88 8.76E-01 FLAG - Service Water Pump PSWOIB Is Not In Operation 1.42 4.21E-01 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation

.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start I 14SE SWTMPUMP1E -04 1.14E-04 SW Pump B in maintenance 15E 0.05 4.55E-02 SWTMPUMP1D 365 TIOOOSW SW Pump D In maintenance Total Loss of Service Water 7.

0 "-03 7.15E-03 PCF PLANT CAPACITY FACTOR 0 1 1.00E+00 0.00+E00 SWAASWPIBNR 0 .88 8.76E-01 FLAG - Service Water Pump PSW01B Is Not In Operation

.42 4.21E-01 SWAASWP1DNR FLAG - Service Water Pump PSWO1D Is Not In Operation 18* .42 4.21E-01 SWMMOSWPAS SWMM0SWPCS FAILURES OF SW PUMP A TO START FAILURES OF SW PUMP C TO START 3.:

3.

"-03 08I 3.28E-03 SWTMPUMPI B SW Pump B In maintenance 0 -03 3.288-03

.05 4.55E-02 SWTMPUMP10 SW Pump D in maintenance 7.1158

-03 7.15E-03 386810000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR 0 1 1.00E+00 0.00E+00 SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation 0 .88 8.76E-01 SWAASWPIDNR FLAG - Service Water Pump PSW0ID Is Not In Operation 0 .42 4.21E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START .42 4.21E-01 3.2 -03 SWTMPUMPIB 0

0. 3.28E-03 SW Pump B in maintenance SWTMPUMP1C 0..05 4.88E-02 SW Pump C in maintenance SWTMPUMP1D .04 3.50E-02 SW Pump D in maintenance 7.115E-03 7.15E-03

367 TI0000SW Total Loss of Service Water PCF I 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWPI BNR FLAG - Service Water Pump PSMIB Is Not In Operation 0.98 0.76E-01 SWAASWP1DNR 0.42 4.21E-01 FLAG - Service Water Pump PSW01 Is Not In Operation 0.42 4.21E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SVWI7MPUMPFA SW PUMp A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1D 0.05 4.55E-02 SW Pump D in maintenance 368 TI0000SW 7.15E-03 7.15E-03 Total Loss of Service Water PCF 1 1.00En00 0.00E+00 PLANT CAPACITY FACTOR SWAASWP1BNR 0.88 8.71E-0I FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWP1DNR 0.42 4.21E-01 FLAG - Service Water Pump PSW01D Is Not In Operation SWMMSWPART 0.42 4.21E-01 FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SWNPump C in maintenance 0.04 3.56E-02 SWTMPUMPID SW Pump D in maintenance 369 TI0000SW 7.15E-03 7.10E-03 Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWPIBNR 0.88 8.76E-01 FLAG - Service Water Pump PSWO1B Is Not In Operation SWAASWP1DNR 0.42 4.21E-01 FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIB 0.03 3.13E-02 SW Pump B1in maintenance 0.05 4.55E-02 SWTMPUMPiD SW Pump D in maintenance 370 TI0000SW 7.15E-03 7.15E-03 Total Loss of Service Water PCF 1 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWPIBNR 0.88 8.76E-01 FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPIDNR 0.42 4.21E-01 FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.00 4.55E-02 SWTMPUMP1C SW Pump C in maintenance SWTMPUMP1D 0.04 3.56E-02 SW Pump D in maintenance 371 TI0000SW 7.15E-03 7.15E-03 Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWPIBNR 0.88 8.76E-01 FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPIDR 0.42 4.21E-01 FLAG - Service Water Pump PSW01D Is In Operation SWMMOSWPCS 0.58 5.79E-01 FAILURES OF SW PUMP C TO START SWMMSWPDRI 3.28E-03 3.28E-03 FAILURES OF SW PUMP D TO RUN SWTMPUMP1A 0.02 2.47E-02 SW Pump A in mainteneance SWTMPUMP1B 0.03 3.13E-02 SW Pump B in maintenance 372 TI0000SW 0.05 4.55E-02 Total Loss of Service Water PCF 1 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWPI BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.88 8.78E-01 SWAASWPIDR FLAG - Service Water Pump PSW0t D Is In Operation 0.42 4.21E-01 SWMMSWPCRT 0.58 5.790E-01 FAILURES OF SW PUMP C TO RUN SWMMSWPDRI 2.051-04 2.05E-04 FAILURES OF SW PUMP D TO RUN SWTMPUMP1A 0.02 2.47E-02 SW Pump A in maintenance SWTMPUMP1B 0.03 3.13E-02 SW Pump B in maintenance 373 TI00OSW 0.05 4.55E-02 Total Loss of Service Water PCF 1 1.00E+00 0.000+00 PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW0 B Is Not In Operation 0.88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.42 4.21E-01 SWMMSWPDRI 0.58 5.79E-01 FAILURES OF SW PUMP D TO RUN SWTMPUMP1A 0.02 2.47E-02 SW Pump A in maintenance SWTMPUMPIB 0.03 3.13E-02 SW Pump B in maintenance SWTMPUMPIC 0.05 4.55E-02 SW Pump C in maintenance 374 TI0000SW 0.04 3.56E-02 Total Loss of Service Water PCF PLANT CAPACITY FACTOR 1 1.000+00 0.00E+00 SWAASWP1BNR 0.88 8.76E-01 FLAG - Service Water Pump PSWO1B Is Nat In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.42 4.21E001 SWTMPUMP1A 0.58 5.790E-01 SW Pump A in maintenance SWTMPUMP1B 0.03 3.130-02 SW Pump B in maintenance SWTMPUMPIC 0.05 4.55E-02 SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGO.94E-07 0.04 3.56E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 375 T10000SW 1 3.45E-03 Total Loss of Service Water PCF 1 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.88 8.76E-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.42 4.21 E-01 SWTMPUMPIA 0.58 5.79E001 SW Pump A in maintenance SWTMPUMP1B 0.03 3.13E-02 SW Pump B in maintenance SWTMPUMP1C 0.05 4.05E-02 SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 0.04 3.56E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.46E-03 370 TIOOOSW Total Loss of Service Water I 3.45E-03 PCF PLANT CAPACITY FACTOR I 1.00E+00 0.00E+00 SWAASWPI BNR FLAG - Service Water Pump PSW0IB Is Not In Operation 0.08 0.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.42 4.21E001 SWTMPUMP1A 0.58 5.79E-01 SW Pump A in maintenance SWTMPUMP1B 0.03 3.13Eo02 SW Pump B in maintenance SWTMPUMPIC SW Pump C In maintenance 0.05 4.55E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ3.04E-07 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.04E-07 1 3.45E-03 377 TIOO0OSW Total Losa of Service Water I 3.45E-03 PCF 1 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWP18NR FLAG - Service Water Pump PSWI1B Is Nat In Operation 0.88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.42 4.21E-01 SWrMPUMPIA 0.58 5.79E-01 SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance 0.03 3.13E-02 SWTMPUMPIC 0.05 4.55E-02 SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 0.04 3.56E-02 UVRERt7B17 BUS 17 UNDERVOLTAGE RELAY 27BI17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 378 T10000SW Total Loss of Service Water I 3.45E-03 PCF PLANT CAPACITY FACTOR I 1.00E+00 0.00E+00 SWAASWPI BNR FLAG - Service Water Pump PSWOIB Is Not In Operation 0.88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.42 4.21E-01 SWTMPUMPIA 0.58 5.70E-01 SW Pump A in maintenance SWTMPUMPIB SW Pump 8 in maintenance 0.03 3.13E-02 SWTMPUMPlC SW Pump C in maintenance 0.05 4.55E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 0.04 3.56E-02 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 379 TI0000SW Total Loss of Service Water I 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.00E+00 0.00E+00 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.42 4.21E-01 SWTMPUMP1A SW Pump A in maintenance 0.58 5.79E-01 SWTMPUMPIB SW Pump B in maintenance 0.03 3.13E-02 SWTMPUMPIC SI Pump C in maintenance 0.05 4.55E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 0.04 3.56E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 1 3.45E-03 3.94E-07 380 T10000SW Total Loss of Service Water 1 3.45E-03 PCF PLANT CAPACITY FACTOR 1 1.O0E+00 0.00E+00 SWAASWP1IBNR FLAG - Service Water Pump PSW0IB Is Not In Operation 0.88 8.76E-01 SWAASWP1DR FLAG- Service Water Pump PSW01D Is In Operation 0.42 4.21E-01 0.08 5.70E-01

SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.552-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ3.84E-07 3.45E-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 3.45E-03 381 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWNTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 3.45E-03 UVREiKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 382 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWPI DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 3.45E-03 UVRERI7BI7 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 383 TI0000SW Total Loss of Service Water 1.00E+00 0.00E.00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pomp PSW01B Is Nat In Operation 0.42 4.21E-01 SWAASWPIDR FLAG -Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWIMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 3.45E-03 384 Tt0000SW Total Loss or Servioe Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW1 B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SW'MPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWIMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 385 T 0OOOONW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BNR FLAG - Service Water Pump PSW0t B Is Not In Operation 0.42 4.21 E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.70E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance UVREKI729C 0.04 3.56E-02 RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2717 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 386 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.78E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance UVREKI729C 0.04 3.56E-02 RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 UVRERI27D7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 387 TI0000SW Total Loss of Service Water 1 1.00+E00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW0iB Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX217 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 388 TI0000SW Total Loss of Service Water 1.002+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW0t B Is Nat In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSWO01DIs In Operation 0.58 5.79E-01 SWTMPUMP1A SWPump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWrMPUMP1C SW Pump C in maintenance UVREKI729O 0.04 3.56E-02 RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2717 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 389 1I0000SW 3.45E-03 Total Loss of Service Water 1.00E+00 0.002E00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSVW0tD Is In Operation 0.58 5.78E-01 SWrMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SIN Pump C in maintenance UVREKI729D 0.04 3.56E-02 RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI27D7 3.452-03 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 390 TI0000SW 3.45E-03 Total Loss of Service Water 1.00E+00 0.00+E00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01 B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SWPumpA in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWrMIPUMPIC SW Pump C in maintenance 0.04 3.562-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.45E-03 3.94E-07 391 TI0000SW 3.45E-03 Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSWM1B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is I Operation 0.58 5.79E-01 SWTMPUMP1A SW PumpA in maintenance SWTMPUMP1B 0.03 3.13E-02 SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance UVREKIB217 0.04 3.56E-02 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI2717 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 392 TIO00OSW 3.45E-03 Total Loss of Service Water PCF 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWPIBNR 0.88 8.76E-01 FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance 0.05 4.55E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 0.04 3.56E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 393 Tf0000SW Total Loss of Service Water 3.45E-03 1.00E+00 0.00E+00

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27E/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 394 TI0000SW Total Loan of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1 BNR FLAG - Service Water Pump PSWO1B Is Nnt In Operation 0.42 4.21E-01 SWAASWP1IDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B In maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 I 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/I 7 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 395 T10000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 878E-01 SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.211E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1 D Is In Operalion 0.58 5.78E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 396 TI0000SW Total Loss of Service Water 1 1.000+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Nat In Operation 0.42 4.210-01 SWAASWPIDR FLAG - Service Water Pump PFW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B In maintenance 0.05 4.55E-02 SWTMPUMP1C SIN Pump C in maintenance 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 397 TI0000SW Total Loss of Service Water 1 1.00E+00 0.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1 B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.58E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 398 T10000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.550-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVRERi27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1 3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/1117 TRANSFERS TO DE-ENERGIZE3.94E-07 1 3.45E-03 399 TIOOOOSW Total Loss of Service Water 1 1.00E+0+ 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPISNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER *B"PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 400 T10000SW Total Loss of Service Water 1 1.000+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 I 4.84E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 401 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPlA SW Pump A i maintenance 0.03 3.13E-02 SWTMPUMPIB SW Pump B In maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.58E-02 402 TIOOOOSW Total Loan of Service Water 1 PCF 1.00nE00 0.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.70E-01 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not tn Operatian 0.42 4.21E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 SWMMSWPBRI 3.28E-03 FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SW"MPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 403 TIO000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 &.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 SWMMSWPART 4.21E-01 FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 SWMMSWPBRI 2.05E-04 FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 SWTMPUMPID 3.56E-02 SW Pump D in maintenance 7.151-03 7.15 E-03 404 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DNR FLAG - Service Water Pump PSWOD Is Not In Operation 0.42 4.21E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWTMPUMPIA 2.47E-02 SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 405 T10000SW 7.15E-03 Total Loss of Service Water 1 PCF 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR 0.88 SWAASWPIBR 8.76E-01 FLAG - Service Water Pump PSW01B In In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWMMSWPDRI 2.47E-02 FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 406 TIOOOOSW Total Loss of Service Water 1 PCF 1.00+00 0.00E+00 PLANT CAPACITY FACTOR 0.88 SWAASWPIBR 8.76E-01 FLAG - Service Water Pump PSW1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWIMPUMPIA 5.70E-01 SW Pump A in maintenance 0.03 SWIMPUMPIC 3.13E-02 SW Pump C in maintenance 0.04 3.58E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGB.94E-07 I UVREKI729C RELAY 2-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 3.45E-03 1

3.45E-03

407 T10000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 UVREKI729D 1 3.45E-03 RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 3.45E-03 408 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSWOt D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQI.94E-07 1 3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/I7 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 409 TI0000SW Total Loss of Service Water 1.008+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 3.45E-03 UVRERI7BI7 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 410 TI0000SW Total Loss of Service Water 1.008+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW1B Is In Operation 1 0.588 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOD Is In Operation 0.88 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER3.O4E-07 UVRERI7BD7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27DI/V17 TRANSFERS TO DE-ENERGIZE3.94E-07 3.45E-03 411 710000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.88 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTIMPUMPIC SW Pump C in maintenance UVREKI7298 0.04 3.56E-02 RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGL94E-07 1 3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1 3.45E-03 412 TI0000SW Total Loss of Service Water 1.008+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWi1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance UVREKI729B 0.04 3.56E-02 RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 UVREKI729D 3.45E-03 RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 3.45E-03 413 TI0000SW Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.798E-01 SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGN.94E-07 1 UVREKIB2I7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 414 TIO300SW Total Loss of Service Water 1.00E+00 O.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSWID Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance UVREKI729B 0.04 3.56E-02 RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 3.45E-03 415 TIOOOOSW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWP1 BR 0.88 8.76E-01 FLAG - Service Water Pump PSW01 B Is In Operation SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVRERI7BD7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27D/BII7 TRANSFERS TO DE-ENERGIZE3.94E-07 419 TI0000SW 3.45E-03 Total Loss of Service Water 1.00E-00 0.001+00 PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWO1 B Is In Operation 0.88 8.78E-01 SWAASWPIDR 0.08 5.79E-01 FLAG - Service Water Pump PSWO1D Is In Operation 0.588 5.798E-01 SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1C 0.03 3.13E-02 SW Pump C in maintenance UVREKI729C 0.04 3.56E-02 RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 417 1I0000SW 3.45E-03 Total Loss of Service Water 1.00E+00 O.OE+00 PCF PLANT CAPACITY FACTOR SWAASWP1BR 0.88 8.786-01 FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIDR 0.88 5.79E-01 FLAG - Service Water Pump PSWO1D Is In Operation 0.88 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 418 TIO0O0SW 3.45E-03 Total Loss of Service Water PCF 1.00E+00 0.001+00 PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.88 8.78E-01 SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSWID Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A in maintenance SWTMPUMPIC SW Pump C In maintenance 0.03 3.13E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 0.04 3.56E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270117 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 419 TI000OSW 3.458-03 Total Loss of Service Water PCF 1.00E+00 0.001+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1DR 0.58 5.79E-01 FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA 0.58 5.79E-01 SW Pump A In maintenance SWTMPUMPIC 0.03 3.13E-02 SW Pump C in maintenance UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 0.04 3.56E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 420 T10000SW 3.45E-03 Total Loss of Service Water PCF 1.00E+00 0.001+00 PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.88 8.76E-01 SWAASWPIDR 0.58 5.79E-01 FLAG - Service Water Pump PSWO10 Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance UVREKI729D RELAY 29-f IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO D08ENERGIZED 3.94E-07 3.45E-03 421 TI00OSW 3.45E-03 Total Loss of Service Water PCF 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR 0.88 8.78E-01

SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 SWAASWP1DR 5.79E-01 FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance UVREKI729D 0.04 3.56E-02 RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D017 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 422 TI0000SW Total Loss of Service Water 1.00E+00 O.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI BR FLAG - Service Water Pump PSFWIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01 D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E.02 SWTMPUMPtC SW Pump C in maintenance 0.04 3.56E.02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 3.45E-03 423 TIO00OSW Total Loss of Service Water 1.00E-00 0.OOE÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1lC SW Pump C in maintenance 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI2717 3.46E-03 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 424 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1IBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.791-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.68 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance UVREKIB217 0.04 3.58E-02 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI27D7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 425 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWTMPUMP1A SWPump A in maintenance 0.03 3.13E-02 SWTMPUMPiC SW Pump C In maintenance 0.04 3.56E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B117 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 3.46E-03 426 T10000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIOR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWTMPUMPlA SW PumpA in maintenance 0.03 3.13E-02 SW'MPUMPIC SW Pump C inmaintenance UVREKIX217 0.04 3.56E-02 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1 UVRERI7BD7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27D/0/17 TRANSFERS TO DE-ENERGIZE3.U4E-07 3.45E-03 427 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI1R FLAG - Service Water Pump PSW01B Is In Operation 0.58 8.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPIC SW Pump C In maintenance UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 0.04 3.56E-02 UVRERI7B17 3.46E-03 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 428 TI00OOSW 3.45E-03 Total Loss of Service Water 1.00E+00 O.00E+00 PCF PLANT CAPACITY FACTOR SWAASWPI1R 0.88 8.76E-01 FLAG - Service Water Pump PSW1t B Is In Operation SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 1 5.79E-01 SWTMPUMP1A SW Pump A inmaintenance 0.58 3.13&-02 SWIMPUMP1C SW Pump C in maintenance 0.03 0.588 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 0.04 3.56E-02 UVRERI7BD7 3.45E-03 BUS 17 UNDERVOLTAGE RELAY 27D/B117 TRANSFERS TO DE-ENERGIZE3.94E-07 0.58 429 TIOGOOSW 3.4E-03 Total Loss of Service Water 1.00E+00 O.00E+00 POF PLANT CAPACITY FACTOR SWAASWP1ER 8.76E-01 FLAG - Service Water Pump PSW01d Is In Operation 0.88 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.581 5.79E-01 SWTMPUMPIA SW PumpA in maintenance 0.58 0.03 3.13E-02 SWTMPUMPIC SW Pump C in maintenance UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D117 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.56E-02 0.04 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27BI17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.45E-03 430 TI0000SW 3.45E-03 Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWPIBR 8.76E-01 FLAG - Service Water Pump PSWO1B Is In Operation 0.88 SWAASWPIDR 5.79E-01 FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWTMPUMPIA 5.79E-01 SW Pump A inmaintenance 0.58 SWTMPUMP1C 3.13E-02 SW Pump C in maintenance 0.03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 3.56E-02 0.04 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 3.45E-03 431 T10000SW 3.45E-03 Total Loss of Service Water PCF 1.008+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWP1BR 8.76E-01 FLAG - Service Water Pump PSWO18 Is In Operation 0.88 SWMMSWPBRI 0.581 5.79E-01 FAILURES OF SW PUMP B TO RUN SWPPJIHDRE SERVICE WATER HEADER "B" PIPING RUPTURE 0.02 2.47E-02 5.53E-07 SWTMPUMPIA 4.84E-03 SW Pump A inmaintenance SWTMPUMP1C 3.13E-02 SW Pump C in maintenance 432 TIOOOOSW Total Loss of Service Water 0.04 3.56E-02 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.88 8.76E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 4.21E-01 3.: 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE 5.53E-07 286.03I SWTMPUMP1C 4.84E-03 SW Pump C In maintenance SWTMPUMP1D SW Pump D In maintenance 0.42 0.04 3.561-02 7.

433 T10000SW 1SE-O3 7.15E-03 Total Loss of Service Water PCF 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWAASWP1CNR FLAG - Service Water Pump PSWI1C Is Not In Operation 8.76E-01 0.88 SWPPJIHDRA SERVICE WATER HEADER "A*PIPING RUPTURE 4.21E-01 S.53E-07 0.42 SWTMPUMP1B I 4.84E-03 SW Pump B in maintenance SWTMPUMP1C 4.55E-02 SW Pump C in maintenance 0.05 SWTMPUMPID 0.04 3.56E-02 SW Pump D in maintenance 7.1 434 T10000SW 18E-03 7.15E-03 Total Loss of Service Water 1 POF 1.0012+00 0.008E00 PLANT CAPACITY FACTOR SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.88 8.76E-01 SWMMSWPCRI 5.79E-01 FAILURES OF SW PUMP C TO RUN 0.58 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 6.53E-07 0.02t SWIMPUMPiB SW Pump 8 in maintenance 4.84E-03 SWTMPUMPID SW Pump D In maintenance 4.55E-02 7.1 0.05 435 T10000SW 5E-03 7.15E-03 Total Loss of Service Water PCF 1 1.006+00 0.006+00 PLANT CAPACITY FACTOR 0.58 8.76E-01 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.211E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.298-o03 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE I 3.28E-03 5.53E-07 SWITMPUMPIC SW Pump C in maintenance 4.84E-03 SWT'MPUMPID 0.04 3.56E-02 SW Pump D in maintenance 7.1 5E-OS 436 T10000SW 7.15E-03 Total Loss of Service Water 1.00E+00 0.001+00

PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIDNR FLAG - Service Water Pump PSWO1D Is Not In Operatien 0.42 421E-01 SWPPJIHDRA SERVICE WATER HEADER " PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 SWTMPUMP1D SWNPump D In maintenance 7.15E-03 7.15E-03 437 TISOOCSW Total Loss of Service Water I 1.00E000 0.0OE+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER A PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 438 TIO000SW Total Loss of Service Water 1 1.00E+00 0.00E000 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Fatlum Of Service Water Pumps To Start 1.14E-04 1.140-04 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWPPJIHDRE SERVICE WATER HEADER B" PIPING RUPTURE 5.53E-07 1 4.84E-03 439 TI0003SW Total Loss of Service Water 1 1.00E+00 0.000+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER A"PIPING RUPTURE 5.53E-07 1 4.84E-03 SWPPJIHDRE SERVICE WATER HEADER B"PIPING RUPTURE 5.53E-07 1 4.84E-03 440 TI0000SW Total Loss of Service Water 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.280-03 SVPPJIHDRA SERVICE WATER HEADER "A"PIPING RUPTURE 5.53E-07 1 4.84E-03 SWPPJIHDRB SERVICE WATER HEADER "Br PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 441 TI000SW Total Loss of Service Water 1 1.00E+00 O.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS 3.28E-03 3.28E-03 FAILURES OF SW PUMP D TO START 3.280E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A7PIPING RUPTURE 5.53E-07 I 4.84E-03 SWPPJIHDRB SERVICE WATER HEADER "B PIPING RUPTURE 5.53E-07 1 4.84E-03 442 TI0000SW Total Loss of Service Water 1 1.000+00 O.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START SWPPJIHDRA 3.28E-03 3.281-03 SERVICE WATER HEADER A" PIPING RUPTURE 5.53E-07 SWPPJIHDRB 1 4.84E-03 SERVICE WATER HEADER 'B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPID SW Pump D in maintenance 7.15&-03 7.15E-03 443 TI0000SW Total Loss of Service Water I 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE SWPPJIHDRB 6.53E-07 I 4.84E-03 SERVICE WATER HEADER'"B PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 444 T1000GW Total Loss of Service Water 1 1.00E+00 0.03E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START SWPPJIHDRA 3.28E-03 3.28E-03 SERVICE WATER HEADER 'A' PIPING RUPTURE 5.53E-07 1 4.84E-03 SWPPJIHDRB SERVICE WATER HEADERSB" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPlB SW Pump B in maintenance 445 TI000SSW 0.05 4.55E-02 Total Loss of Service Water 1 1.00E000 0.000200 PCF PLANT CAPACITY FACTOR SWMMSWPART 0.88 8.76E-01 FAILURES OF SERVICE WATER PUMP A TO RUN SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE 2.05E-04 2.05E-04 SWPPJIHDRS SERVICE WATER HEADER '"S PIPING RUPTURE 5.53E-07 I 4.84E-03 5.53E-07 1 4.84E-03 SWTMPUMPiC SW Pump C in maintenance 446 TIOoOOSW 0.04 3.50E-02 Total Loss of Service Water 1 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWMMSWPCRT 0.88 8.76E-01 FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE 2.03E-04 2.05E-04 SWPPJIHDRB SERVICE WATER HEADER "'" PIPING RUPTURE 5.53E-07 1 4.84E-03 5.53E-07 1 4.84E-03 SWTMPUMPlA SW Pump A In maintenance "447 110000SW Total Loss of Service Water 0.03 1

3.13E-02 1.00E+00 0.00E+00 PCF PLANT CAPACITY FACTOR SWMMSWPDRT 0.88 $.78E-01 FAILURES OF SW PUMP D TO RUN SWPPJIHDRA 2.05E-04 2.05E-04 SERVICE WATER HEADER 'A' PIPING RUPTURE 5.53E-07 1 4.84E-03 SWPPJIHDRB SERVICE WATER HEADER"B" PIPING RUPTURE 5.53E-07 1 4.84E-03 SWTMPUMPIB SW Pump B in maintenance 448 TIOO0OSW 0.05 4.55E-02 Total Loss of Service Water 1 PCF PLANT CAPACITY FACTOR 1.00E+00 0.00E+00 SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE 0.88 8.76E-01 5.53E-07 1 4.84E-03 SWPPJIHDR8 SERVICE WATER HEADER 'B' PIPING RUPTURE SWTMPUMP1A SW Pump A In maintenance 5.53E-07 1 4.84E-03 SWTMPUMP1C 0.03 3.13E-02 SW Pump C in maintenance 449 TIOO00SW 0.04 3.56E-02 Total Loss of Service Water 1 PCF 1.00E+00 0.00E+00 PLANT CAPACITY FACTOR SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE 0.88 8.76E-01 SWPPJIHDRS SERVICE WATER HEADER "B"PIPING RUPTURE 5.53E-07 I 4.84E-03 5.53E-07 1 4.84E-03 SWTMPUMPIS SW Pump B In maintenance SWTMPUMP1D SIN Pump D in maintenance 0.05 4.55E-02 7.15E-03 7.150-03 Report Summary:

Filename: D:ACAFTA-VIOQUANTtEVELIILSW-IN- .CUT Print date: 068222001 1:15 PM Not sorted Printed In full

ATTACHMENT 5 June 29, 2001 Email From RGE To NRC,

Subject:

Loss of SW SDP

Mail Envelope Properties (3B3CAOA5.FDA* 22: 8154)

Subject:

Loss of SW SDP Creation Date: 6/29/01 11:36AM From: <Mark_Flaherty@rge.com>

Created By: Mark_Flaherty@rge.com Recipients nrc.gov kpI_po.KP__DO FJA (Frank Arner)

WLS (Wayne Schmidt)

JMT1 (James Trapp) rge.com Thomas _Harding CC Post Office Route kp lpo.KPDO nrc.gov rge.com Files Size Date & Time MESSAGE 111 06/29/01 11:36AM RiskQuestions.wpd 36497 Header 1000 Options Expiration Date: None Priority: Standard Reply Requested: No Return Notification: None Concealed

Subject:

No Security: Standard

From: <MarkFlaherty@rge.com>

To: <JMTil@nrc.gov>, <wls@nrc.gov>, <FJA@nrc.gov>

Date: 6/29/01 11:37AM

Subject:

Loss of SW SDP Based on conversations with Jim Trapp on Wed, here is a revised letter:

(See attached file: RiskQuestions.wpd)

CC: <ThomasHarding@rge.com>

SDP Questions Ginna SSDI In order to ensure that everyone is talking from the same page, here is a summary of the expected loss of service water (LOSW) scenario that will be used as a reference point in responding to the NRC questions.

A. Given a LOSW, the plant would trip either automatically or manually within a few minutes due to loss of BOP related equipment, CCW to the RCPs' etc. The following equipment (as a minimum) will be assumed failed due to the loss of SW:

  • IA Compressors A, B, C. However, the service air compressor (normally cross tied to IA) and the diesel air compressor are available.
  • MDAFW Pumps A and B. However, the TDAFW pump will auto start on low SG level (shrink due to reactor trip) and the SAFW pumps will be available.
  • CCW high temperature alarms will result in tripping the CCW pumps. This will fail cooling to the RCPs (which will also be tripped) and the RHR heat exchangers (failing sump recirculation and RHR cooldown).

° MFW and Condensate pumps B. Once the plant has tripped, the operators enter procedure E-0. It would be expected that SI conditions would not exist (nor a manual SI required) and operators would exit E-0 after step 4 and enter procedure ES-0.1.

C. Upon exiting E-0, the STA would consult the Critical Safety Function Status Trees (CSFSTs) per EOP usage guides (procedure A-503. 1) and the note prior to the first step in ES-0.1. Included within the CSFSTs is verification that there is 200 gpm total AFW flow and 5% level in at least one SG. The STA performs this verification approximately once every 10-20 minutes (step 3.2.10.3 of procedure A-503.1). At this point, there is

- also a shift briefing to discuss-the plant status. It would be expected that the loss of SW would be discussed, but we will assume that this is not discussed for the purpose of this review.

D. Procedure ES-0.1 provides instructions to the operators to stabilize the plant and bring it to hot shutdown conditions. There is a step to verify the number of operating SW pumps

(#5) and a continuous action step (#9) to verify SG level > 5%. The last step of the procedure requires the operators to consult plant staff to determine if cooldown is required and to go to procedure ES-0.2 for natural circulation cooldown (since there are no RCPs). It can be assumed that between the plant staff and licensed operators, that a decision would be made to limit the plant cooldown with no SW present since CCW and RHR are not available. However, it will be assumed that the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> run time with no SW lube oil cooling to the TDAFW pump will not be identified since this is only found in procedure ECA-0.0 (SBO).

E. Procedure ES-0.2 instructs the operators to cooldown and depressurize the RCS using natural circulation. As mentioned above in D, it can be assumed that the plant cooldown would be limited with no SW available. However, it will now be assumed that the TDAFW pump fails after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of operation with no SW cooling for lube oil. Since AFW and maintaining SG level is a basis for providing natural circulation, it would be expected that operators would be monitoring it closely. The STA would also be monitoring these as part of the CSFSTs once every 10-20 minutes. Between these and the expected control board alarms, operators would transition to FR-H.1 upon loss of the TDAFW pump.

F. Procedure FR-H. 1 instructs the operators to restore feedwater flow to the SGs first by preferred AFW, then by MFW, then by SAFW. Preferred AFW and MFW will be

assumed unavailable such that only SAFW can be used. EOP Attachment 5.1 instructs the operators to align SAFW taking suction from SW. Procedure ER-AFW. 1 provides instructions on how to use alternate suction sources (e.g., city and fire water); however, there is no direct links to ER-AFW.1 from FR-H.1 and Attachment 5.1 other than CST level < 5 feet. Regardless, the operators know that SW is unavailable and have been trained on the use for ER-AFW. 1 for similar type circumstances. That is, ER-AFW. 1 is considered to be an Abnormal Operating Procedure (AOP) that is referenced by the EOP series of procedures. Operators are trained and expected to utilize AOP type of procedures as needed in support of EOP implementation. Also, the minimum CST level specified in LCO 3.7.6 is based on providing sufficient inventory for the TDAFW pump for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> post trip in accordance with NUREG-0737, item II.E.1.1. As such, the operators would be expected to be procedurally directed into ER-AFW. 1 from low CST level at about the same time that the TDAFW pump would fail due to insufficient lube oil cooling.

See also H and I below.

G. If AFW, MFW, and SAFW cannot be implemented by FR-H. 1, then the operators are instructed to use the condensate system or implement feed and bleed. The condensate system requires SW for motor cooling and would be unavailable. Feed and bleed occurs until necessary subcooling margin is obtained such that the SI pumps can be stopped and the PORVs closed. At this time, the plant would go to normal RHR shutdown cooling (requires SW), sump recirculation (requires SW), or stabilize on AFW that has been restored. Assuming a SI flowrate of 500 gpm (each pump is designed for 350 gpm and given the initial lower decay heat levels) and 300,000 gallons of RWST inventory, the need to be on RHR or AFW would not occur before 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />. It can be expected that either SW, the TDAFW pump, or SAFW would be recovered within this time frame.

However, the PSA model assumes that recirculation capability is required (i.e., there is no credit for this recovery).

H. With respect to the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> run time of the TDAFW pump, attached is the current UFSAR description of this issue. As can be seen, there have been several tests of operating the TDAFW pump without any service water. The following summarizes these tests:

On March 6-8, 1981, RG&E conducted a 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> Endurance Test of all AFW pumps, including the TDAFW pump, in support of TMI Item II.E.1.1. The TDAFW pump was run on recirculation flow rate of 125 gpm for the duration of the test.

SW was isolated to the TDAFW pump (pump outboard bearing, quench tank, and lube oil cooling) at the onset of the test. One hour into the test, it was identified that the SW inlet valve to the pump outboard bearing was leaking by and the outlet valve was closed at that time. Steam then began emitting from the funnel drain at the pump bearing and at 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> 55 minutes, SW was restored to prevent the steaming from impacting the nearby control rod drive cabinets and causing a reactor trip. At 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> into the test, SW was again isolated to the TDAFW pump but restored to the outboard bearing 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 50 minutes later due to steaming issues again. The lube oil cooler remained isolated until 39 hours4.513889e-4 days <br />0.0108 hours <br />6.448413e-5 weeks <br />1.48395e-5 months <br /> into the test (i.e. for 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />). All pump parameters were within manufacturer recommendations.

  • On April 17, 1981 the TDAFW pump was run for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> without SW cooling under accident conditions (i.e., 200 gpm). All pump parameters were within manufacturer recommendations.

Based on the above, it is extremely conservative to assume that the TDAFW pump will fail after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of no SW cooling. It has been demonstrated that the TDAFW pump can run without lube oil cooling for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> under recirculation flow conditions

and 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> under design flow conditions. It has also been demonstrated that the TDAFW pump can run without cooling to the outboard bearing for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 55 minutes (with no credit for the first 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with a leaking SW valve) under recirculation flow conditions and 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> under design flow conditions. The only reason that these times are less than the lube oil cooler is due to test constraints and the desire to prevent a potential reactor trip, not from TDAFW pump operability concerns.

LCO 3.7.6 requires that one CST be filled up to 21.5 feet (22,500 gallons) to ensure 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of TDAFW water post-trip. However, Ginna Station has two CSTs, both of which are normally in service. Discussions with control room personnel indicate that they normally maintain the CSTs at approximately 21 feet (low level alarms begin to occur at 19 feet with overfill at around 23 feet). Since this is intended to be a PSA based, best estimate calculation, we can assume both tanks are at 21.5 feet (45,000 gallons). We can also assume that the TDAFW pump will run at 200 gpm for the first hour, 175 gpm for the second hour and 125 gpm for the subsequent hours based on decay heat loads.

Using this, we can calculate the time to reach 5 feet in both tanks (typical entry into ER AFW.1 per the EOPs):

  • If 21.5 feet equals 22,500 gallons, then 5 feet equals 5,232 gallons, or 10,464 gallons for two tanks.
  • Given the TDAFW pump flow rates, we calculate the inventory used as: 200 gpm (60 min) + 175 gpm (60 min) + 125 gpm (x min), or 22,500 gallons + 125x.
  • To calculate the time to reach 5 feet in both tanks:
a. 45,000 gallons (2 full tanks) - 10,464 gallons (5 ft) = (22,500 gallons +

125x)

b. 34,536 gallons = 22,500 gallons + 125x
c. x = 96 mins, or within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> of the event
1. Does the Ginna PRA assume the need for the crosstie of the cooling water from the fire main for total loss of service water scenarios? If so, was the assumption of the frequency of success the same as assumed in AFHDALTTD? If so, this does not appear appropriate since the operator must recognize (proceduralized) the loss of fire water and take actions to align the city water to the fire headers (proceduralized) and also recognize (not proceduralized) the need to connect the temporary supply hose (proceduralized).

As indicated in PSA Final Report, Appendix F, Table F-4, event AFHFDALTTD is only credited for SBO scenarios (i.e., scenarios where procedure ECA-0.0 is entered). All other scenarios use a value of 1.0 for using fire water to support the TDAFW pump.

2. How would you estimate the Diagnosis HEP for the LOSW event, (given no procedure guiding the operator recognition) verse time for:
a. The alignment of CitylFire water to the TDAFW pump of the need to complete Att-5.2?
b. The alignment of City Water to SAFW?

The diagnosis for alignment of fire water to the TDAFW pump (AFHFDALTTD) and city water to SAFW (AXHFDCITYW) was based on the following:

a. AFHFDALTTD - Cues to perform this action would only be available upon entering ECA-0.0, Step 8.d. All other scenarios do not credit this action (i.e.,

failure probability of 1.0).

b. AXHFDCITYW - Cues to perform this action would be from one of the following:

(1) low CST level - found on foldout page of all EOPs; (2) Step 13.a RNO of Procedure FR-C.1 for inadequate core cooling if SG level cannot be maintained >

5%; (3) Auxiliary Operator (AO) monitoring of the TDAFW per Step 3.6.3 of Procedure OPS-SHIFT-RESP which states "during abnormal or emergency conditions, the AOs shall be available to perform equipment monitoring and any local manipulations necessary, as directed by the SS, CRF, or Control Operators"; and (4) Step 7 of Procedure FR-H.1 for inadequate heat sink if SAFW cannot be aligned to SW. Note that for the last item, there is no direct procedural guidance. However, as described in item F of the event summary, operators are expected to utilize AOPs like ER-AFW. 1 in a situation like this. The calculation of this value was previously provided to the NRC and assumes that the operator had 20 minutes of diagnosis available. With 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of successful TDAFW operation, this diagnosis time would be much longer.

3. Was the Total mean HEP for the City water to fire water ever calculated? Has it been calculated now? If so what is it? 'Please include the calculation).

No HEP for this event has ever been calculated, nor is there any intention of generating one at this time. Instructions to perform this step are not contained within-the EOP and AOP series of procedures (i.e., they are ir', other plant testing procedures). However, this activity is performed during testing and maintenance of the fire water systems and is called out in the TRM for when both fire pumps are inoperable (i.e., establish a backup fire water system). That is, operators are :aware of this capability.

4. Reiative to crediting feed and bleed for a LOSW - What does the current PRA assume? We think that the SDP assumes no feed and bleed because-the recirc capability would not be available. Doez the PRA assume anything relative to the time dependance until the RWST reaches the point for swapover? Are there procedures in place for establishing a source of cooling water to the RHR Hxs, without SW?

The PSA utilizes a single transient event tree which contains, among other transients, the LOSW event (see PSA Final Report Figure 5-1). For the feed portion of feed and bleed, top event UH1 on the figure (High Pressure Injection) contains the logic for gate SR500, FAILURE TO DELIVER FLOW FROM I OF 3 SI PUMPS TO THE RCS DURING RECIRC. Since no recovery of SW is credited (as described in the event summary, item G), feed and bleed is not success for a LOSW event. However, since it would take over 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> to deplete the RWST, it could be postulated that the SW or AFW system would be recovered, or even the RWST refilled. There is no procedure which establishes an alternate source of cooling to the RHR HXs, primarily due to the number of AFW pumps.

5. What is the current PRA core damage prob for LOSW? What would the LOSW core damage probability be given: (for each please include the sequences of interest and the assumed failure probabilities. Iffeed and bleed is credited please explain how.)
a. Inability to align Firewater to the TDAFW pump (given nominal failure probability for aligning city water to SAFW).
b. Inability to align Firewater to the TDAFW pump and inability to align city water to SAFW.

Three LOSW scenarios were solved as described beiow. In no instance is credit for feed and bleed taken.

LOSW as currently addressedwithin the PSA model - The attached cutset file (LOSW1 .XLS) shows a of CDF 3.035E-06 with risk dominated by transients with no AFW available. Note that event AFHFDALTTD is only found in combination with a SBO event. Also, AXHFDCITYW is not found in the cutsets. This is due to the fact that there is already a human error event of failing to start SAFW per EOP steps (AXHFDSAFWX) within the models. For LOSW, this event also includes failure to align city water since no SW is available at the outset.

Consequently, event AXHFDSAFWX was increased by the necessary factor to result in a failure probability of 1.OE-02 similar to AFHFDALTTD.

LOSW with no credit for aligning Firewaterto TDAFW - this is the same as the first sequence since event AFHFDALTTD is only credited for SBO cutsets.

LOSW with no credit for aligning Firewaterto TDAFW nor city water to SAFW- If no credit is taken for TDAFW and the SAFW systems, then the CDF is equivalent to the LOSW frequency, or 2.OOE-04/yr (LOSW2.XLS). However, this scenario is not considered credible due to the reasons described below:

a. Operators treatment of ER-AFW.1 as a AOP which is entered as necessary in the EOPs.
b. Operators would initialize SAFW using FR-H. 1 once the TDAFW pump failed. Since this would not be expected to be implemented for at least 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> following the LOSW, operators would only need one SAFW pump due to low decay heat levels. The operator would start one pump which would quickly fail with no suction source if he attempted to use SW as the suction source as the procedure describes. Based on the extensive use of STAR practices, the operator would be expected to question why the pump failed before attempting to start a second SAFW pump.
c. If operators failed to align city water to SAFW in FR-H. 1, they would go to feed and bleed. Once this failed due to lack of RWST inventory and ability to go onto RHR, the core would heat up and the operators would enter FR-C.1. This procedure has specific guidance to enter ER-AFW.1 in step 13.a RNO for when SG level is < 5% and 200 gpm of AFW cannot be established..
d. AOs would be expected to be monitoring the status of the TDAFW pump as required by the procedure outlining shift responsibilities. This is especially true if the TDAFW pump is the only operating preferred AFW pump. If the AO identified pump problems (temperatures, steam, etc),

they would notify the control room who would be looking at alternatives.

e. As described in items H and I, the CST low level alarms are expected to occur at just over 3.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> into the event with an operating TDAFW pump. Based on the tests conducted in 1981, failure of the TDAFW pump is not expected to occur prior to this time. That is, the March 1981 test

was conducted with only a leaking SW valve supplying the outboard bearings for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and no SW cooling for the subsequent 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and 55 minutes.

Even assuming a generic operator failure rate of 0.1, and that items b and c are dependent (i.e., single event), this amounts to an operator error rate of 1 E-03 to start a SAFW pump under this scenario if the TDAFW pump were assumed to fail at an unlikely time of only 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

UFSAR 10.5.4.2 Alternating Current Independence of the Turbine-Driven Auxiliary Feedwater Pump (TDAFWMF As part of the review for NUREG 0737, Item II.E.1.1, Ginna Station was evaluated to determine if there was an essential dependence of the turbine-driven auxiliary feedwater pump (TDAFW) system on ac power. It was determined that the only ac dependence was the need for service water (SW) cooling of the lube-oil for the turbine-driven pump. The turbine-driven feedwater pump (TDAFW) has an ac lube-oil pump and a dc lube-oil pump. These pumps direct the oil through a heat exchanger, which depends on the ac-powered service water (SW) system pumps to cool the oil. The outboard (thrust) bearing of the pump is also provided directly with service water cooling through a water jacket within the bearing housing. The inboard pump radial bearing is cooled by an oil bath without an external source of cooling water. In the event:.

of a total loss of ac power, lube-oil cooling capability for the turbine-driven pump will be lost due to the loss of ac power to the service water (SW) pumps.

An NRC criterion (Recommendation GL-3 of NUREG-0737 Action Item I1.E.1.1) was that the as-built plant should be capable of providing the required preferred auxiliary feedwater flow for at least 2 hr from one preferred auxiliary feedwater pump train independent of any ac power source. As part of the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> Endurance Test conducted on March 6-8, 1981, RG&E performed a test with service water (SW) secured to the turbine's lube oil cooler and the pump outboard (thrust) bearing. The pump was run for a duration of 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> 55 minutes in one sequence without any service water cooling and for 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> in a later sequence without service water cooling to the turbine lube oil cooler. During the first sequence, excessive steaming from the floor drains with service water secured caused the reinitiation of service water (SW) to the pump thrust bearing. The Endurance Test was run in the recirculation mode with 125 gppm passing through the recirculation line back to the condensate storage tanks (CST). Throughcut the testing without service water supplied, the pump outboard (thrust) bearing, which is service, water cooled, and the inboard pump radial bearing (oil bath) were within manufacturer's limits of 165°F. The turbine governor bearing return oil temperature and turbine inboard bearing return oil temperature, as well as the turbine lube oil reservoir temperature, stabilized well within the manufacturer's limit of 180 0 F.

In addition to the Endurance Test, another test was performed on April 17, 1981, for a period of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> without service water cooling to the outboard pump bearing and turbine lube oil cooler, this sequence with the pump delivering 200 gpm (100 gpm to each steam generator). This test was performed to simulate accident conditions. This test also confirmed that oil temperature, as well as pump and turbine bearing temperatures stabilized within acceptable limits.

In a letter dated June 8, 1981 (Reference 7) RG&E submitted the test results for these tests.

In a letter dated June 16, 1982 (Reference 5) the NRC concluded that, based on the results of the recirculation flow test and the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> test on April 17, 1981, RG&E has shown that the turbine-driven auxiliary feedwater system (TDAFW) does not have an essential ac power dependence.