ML012000255
| ML012000255 | |
| Person / Time | |
|---|---|
| Site: | Ginna |
| Issue date: | 07/18/2001 |
| From: | Doerflein L NRC Region 1 |
| To: | NRC Region 1 |
| References | |
| -RFPFR IR-01-005 | |
| Download: ML012000255 (138) | |
Text
- MEMORANDUM**
Public Docket Room FROM:
SUBJECT:
Lawerence T. Doerflein, Chief Systems Branch E-MAIL CORRESPONDENCE BETWEEN NRC AND RGE FROM JUNE 12 TO JUNE 29, 2001 Attached to this memo are a series of email correspondense that took place between the NRC and Rochester Gas and Electric (RGE) personnel from the R.E. Ginna Nuclear Power Plant between June 12 to June 29, 2001. The information contained within these e-mails was used during the course of an NRC baseline inspection, which will be documented in NRC inspection report 05000244/2001005.
Attachments: 1. June 12, 2001 Email From NRC To RGE,
Subject:
- 2. June 13, 2001 Email From RGE To NRC,
Subject:
- 3. June 18, 2001 Email From NRC To RGE,
Subject:
- 4. June 22, 2001 Email From RGE To NRC,
Subject:
NRC Questions
- 5. June 29, 2001 Email From RGE To NRC,
Subject:
Cý;IaA"ýýý
ATTACHMENT I June 12, 2001 Email From NRC To RGE,
Subject:
Mail Envelope Properties (3B266CAB.8A6: 10: 35430)
Subject:
Re: Loss of SW SDP Creation Date:
6/12/01 3:25PM From:
Wayne Schmidt Created By:
WLS@nrc.gov Recipients nrc.gov kplpo.KPDO AXL CC (Alfred Lohmeier)
FJA CC (Frank Amer)
GWM2 CC (George Morris)
PDK CC (Paul Kaufman)
SMP CC (Stephen Pindale) rge.com ThomasHarding (ThomasHarding@rý,*.com)
Post Office Route kp lpo.KPDO nrc.gov rge.com Files Size Date & Time MESSAGE 5965 06/12/01 03:25PM Options Expiration Date:
None Priority:
Standard Reply Requested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard
From:
Wayne Schmidt To:
Thomas_- Harding@rge.com Date:
6/12/01 3:25PM
Subject:
Re: Loss of SW SDP Hi Tom - just a few thoughts from a team meeting we had today.
- 1) We would like to know the basis for the operator failure rates quoted in the previous e-mail.
- 2) We are unable to find a procedure that directs the use of the city water to SAFW following a LOSW if the CST is not depleted. (i.e.,no step in ATT-5.1 to verify the avavability of the SW
, suction source or lineup city water)
- 4) Is there a cross tie from city water to the firemain in the IB, if so what directs its use?
>>> <ThomasHarding@rge.com> 06108/01 02:09PM >>>
FYI, here is a little more info from Mark. Both of us will be unavailable on Monday, and Mark will also be gone Wed. through Friday. Tuesday is good for both of us.
Forwarded by Thomas Harding/NOG/RG&E on 06/0812001 02:07 PM Mark Flaherty 06/08/2001 01:00 PM To: Thomas Harding/NOG/RG&E@RG&E cc:
Subject:
Loss of SW SDP Since I will only be in the office on Tues next week, I performed an additional review of the SDP as sent by the NRC on 12/29/00 related to the loss of SW procedure issue identified in the NRC inspection. Based on this, I would like to offer the following:
Event Tree 10 (LSSW) is missing all feed and bleed (F&B) functions.
This apparently was done on the premise that F&B requires SI, PORVs, and all supporting functions. SI has no SW dependencies as described in the PSA Final Report (Section 6.17.4.d) and the Ginna UFSAR (Section 6.3.2.2.2.1). At the time the event trees were being developed, there was some question about whether the PORVs, on nitrogen only, was sufficient for F&B. RG&E agreed that it was not and the PSA now requires IA in addition to nitrogen for F&B purposes. Table 2 of the 12/29/00 SDP identifies through Note 8 that the Service Air compressor is air cooled and does not require SW. Therefore, F&B should be
considered for the LSSW event tree (and for the for loss of CCW tree).
I would imagine this would would have a large effect on the results.
The SDP Worksheet for loss of SW (Table 3.12) identifies a failure rate of 0.1 for the operators to align city water to the SAFW system and to provide fire water to the TDAFW lube oil cooler. The PSA currently uses 1.OOE-02 and 6.70E-03 for these events, respectively (or at least one order of magnitude lower). However, the following things should be pointed out:
If all SW is lost, then fire water to the TDAFW pump is likely lost since they take suction from a similar location. City water to SAFW would remain available since this is a different source. The PSA reflects this by the fact that event SWCXXSUCTN, TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION fails both SW and the fire water pumps.
This event forms the basis for most of the frequency of losing all SW as an initiator (versus the random failure of 4 SW pumps).
The PSA operator failure rates are based on losing all AFW at the start of the transient. If the TDAFW pump runs for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> before failing, there is a lot of additional time before SG tube uncovery that would lead to a more likely operator success.
I hope these help.
CC:
GINNASSDI
ATTACHMENT 2 June 13, 2001 Email From RGE To NRC,
Subject:
Mail Envelope Properties (3B276D56.8F8 :13 : 6392)
Subject:
Creation Date:
From:
Created By:
Re: Loss of SW SDP 6/13/01 9:39AM
<ThomasHarding@rge.com>
ThomasHarding@rge.com Recipients nrc.gov kplpo.KP DO WLS (Wayne Schmidt)
Post Office kplpo.KPDO Route nrc.gov Files MESSAGE 3-16-4-1.1 Header Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
Size 1557 26167 1004 Date & Time 06/13/01 09:39AM None Standard No None No Standard
From:
<ThomasHarding@rge.com>
To:
'Wayne Schmidt" <WLS@nrc.gov>
Date:
6/13/01 9:41AM
Subject:
- 1) I'm e-mailing the info that Mark provided, any detailed discussion of this should probably wait until next week.
- 2) The lineup is controlled by ER-AFW.1, which is entered from about a bazzilion EOPs. I'll assume that you still have a copy of this. The procedure is intended to give the Operators many options in getting water into the steam generators. To some degree you need to rely on RO/SRO training.
- 3) no response requested.
- 4) I attached procedure SC-3.16.4.1 (it's in WordPerfect). This procedure is utilized by Operations anytime there is major maintenance of the fire system (like today!).
(See attached file: 3-16-4-1.1)
"Wayne Schmidt" <WLS@nrc.gov> on 06/12/2001 03:25:31 PM To: <ThomasHarding@rge.com>
cc:
"Alfred Lohmeier" <AXL@nrc.gov>, "Frank Arner" <FJA@nrc.gov>, "George Morris" <GWM2@nrc.gov>, "Michael Modes" <MCM@nrc.gov>, "Paul Kaufman"
<PDK@nrc.gov>, "Stephen Pindale" <SMP@nrc.gov>
Subject:
Re: Loss of SW SDP Hi Tom - just a few thoughts from a team meeting we had today.
- 1) We would like to know the basis for the operator failure rates quoted in the previous e-mail.
- 2) We are unable to find a procedure that directs the use of the city water to SAFW following a LOSW if the CST is not depleted. (i.e.,no step in ATT-5.1 to verify the avavability of the SW suction source or lineup city water)
to apply.
- 4) Is there a cross tie from city water to the firemain in the IB, if so what directs its use?
ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER PROCEDURE NO.
SC-3.16.4.1 REV. NO. 9 CROSS TIE OF DOMESTIC WATER SUPPLY TO FIRE SERVICE WATER SYSTEM RESPONSIBLE MANAGER EFFECTIVE DATE GINNA STATION UNIT #1 COMPLETED DATE:
TIME:
CATEGORY 1.0 REVIEWED BY:
THIS PROCEDURE CONTAINS 7
PAGES
1.0 1.1 SC-3.16.4.1: 2 Rev. 9 SC-3.16.4.1 CROSS TIE OF DOMESTIC WATER SUPPLY TO FIRE SERVICE WATER SYSTEM PURPOSE To provide adequate water supplies to the on-site fire service water system header in the event of a loss of the Electric and Diesel Fire Pumps or as directed by the Site Fire Protection Engineer/Designee and Shift Supervisor.
To provide instructions to site personnel regarding the proper method of completing the cross connection.
To prevent cross contamination between the on-site fire service water system and the potable domestic water system supplied by the Ontario Water Authority.
REFERENCES GAI Drawing # D-381-301.
GAI Drawing # D-381-302.
INSTRUCTIONS Obtain permission from Shift Supervisor to perform this procedure.
Contact Maintenance and Fire Protection and Safety for equipment and support.
At Domestic Hydrant #7 remove both 2.5" discharge caps.
Tighten large discharge cap.
Open hydrant fully and allow a full flow of water to flush main of any foreign matter.
Shut down hydrant and place a 2.5" gate valve on each discharge port, then connect approximately 100' of 3" fire hose to each gate valve.
NOTE All connections to yard hydrants shall utilize gated valve devices for quick isolation and personnel safety purposes.
1.2 1.3 2.0 2.1 2.2 3.0 3.1 3.1.1 3.2 3.2.1 3.2.2
SC-3.16.4.1: 3 Rev. 9
SC-3.16.4.1: 4 Rev. 9 3.2.3 Route hose to wall valve #5158. Place back flow protectors on each input point. Be sure flow of water is from yard hydrant to wall hydrant.
3.2.4 Connect fire hose to back flow protectors.
3.2.5 Open hydrant #7 slowly and completely.
3.2.6 Open hydrant gate valves slowly and completely.
3.2.7 Once pressure has equalized between hydrant and hose, open valve #5158 fully.
3.2.8 Inspect hose and connections for any signs of leakage.
3.3 At domestic fire hydrant #8, remove both 2.5" discharge caps. Tighten large discharge cap.
3.3.1 Open hydrant fully and allow a full flow of water to flush main of any foreign matter.
3.3.2 Shut down hydrant and place a 2.5" gate valve on each discharge port, route and then connect approximately 100' of 3" hose to each input connection for the Service Building sprinkler system. (Located outside on the NE corner of the Service Building).
NOTE This connection does not require additional back flow protection since valve #5199N provides this function.
3.3.3 Once all connections have been completed, leave #8 hydrant secured. This hydrant will only be utilized in the event of a failure at one of the other locations.
NOTE Wall hydrant valve #5157 will also be left as is. This will allow further supply if needed at a later date by drafting from the discharge canal with a fire department pumper and connecting 2 additional hoses from that operation to this location.
3.4 At domestic hydrant #9 or #10, remove both 2.5" discharge caps. Tighten large discharge cap.
3.4.1 Open hydrant fully and allow a full flow of water to flush main of any foreign matter.
3.4.2 Shut down hydrant and place a 2.5" gate valve on each discharge port, then connect approximately 200' for hydrant #9 and approximately 350' for hydrant
- 10 of 3" fire hose to each gate valve.
SC-3.16.4.1: 5 Rev. 9 3.4.3 Route hose lengths to valve #51 56 located outside the Oil Storage Building.
Place back flow protectors on each input point and connect hoses. Be sure flow of water is from yard hydrant to wall hydrant.
NOTE Where fire hose crosses the plant driveway place hose in a hose bridge to protect from damage.
3.4.4 Open hydrant #9 or #10 slowly and completely.
3.4.5 Open hydrant gate valves slowly and completely.
3.4.6 Inspect fire hose and couplings for any signs of leakage.
3.4.7 Open wall hydrant valve #5156 slowly and completely.
3.5 At hydrant #11 or #13 remove, 2.5" discharge caps. Tighten large discharge cap.
3.5.1 Open hydrant fully and allow a full flow of water to flush the main of any foreign matter.
3.5.2 Shut down hydrant and place a 2.5" gate valve on each discharge port, then connect approximately 250' for hydrant #11 and approximately 200' for hydrant #13 of 3" fire hose to each gate valve.
3.5.3 Route hose to wall hydrant valve #5155 located outside the Auxiliary building east side. Place back flow protectors on each input point and connect hose.
Be sure flow is from yard hydrant to wall hydrant.
NOTE Where fire hose crosses plant driveway place hose in hose bridge to protect from damage.
3.5.4 Open hydrant #11 or #13 slowly and completely.
3.5.5 Open hydrant gate valves slowly and completely.
Once pressure has equalized, inspect all hose and couplings for signs of leakage.
3.5.6
SC-3.16.4.1: 6 Rev. 9 3.5.7 Open wall hydrant valve #5155 slowly and completely.
NOTE Should this procedure be utilized during winter months, each fire hose and opened hydrant will require heat tracing and or insulation to prevent freezing.
Where this is not practical, a positive water flow must be maintained on each fire hose.
NOTE Should manual fire fighting require assistance from local fire departments, DO NOT ALLOW ANY ADDITIONAL CONNECTIONS ON THE DOMESTIC YARD HYDRANT SYSTEM WITHOUT APPROVAL BY THE FIRE PROTECTION ENGINEER AS THESE CONNECTIONS COULD REDUCE AVAILABLE WATER SUPPLIES TO THE PLANT.
NOTE Additional water is available by drafting with a fire department pumper from the discharge canal.
3.5.8 Independent verification by a knowledgeable individual, normally an AUX Operator (Active or inactive) or the Fire Protection Engineer to ensure that the cross tie is established in accordance with this procedure.
3.6 Cross tie disconnection.
3.6.1 Shut down wall hydrant valve #5158.
3.6.2 Shut down hydrant #7 and relieve hose pressure by loosening up the couplings at the hydrant.
3.6.3 Once the hose is depressurized, remove hose from hydrant and wall hydrant valve #51 58.
3.6.4 Disconnect each coupling and drain, clean and roll up hose and return to storage.
3.6.5 Place caps back on hydrant and wall hydrant #5158.
NOTE Loosen steamer cap on hydrant so it is hand tight.
3.6.6 Disconnect hose at the fire dept. connection for the Service Building sprinkler system and at hydrant #8.
3.6.7 Disconnect each coupling and drain, clean, roll up and return hose to storage.
3.6.8 Place caps back on hydrant and fire dept. connection.
NOTE Loosen steamer cap on hydrant so it is hand tight.
SC-3.16.4.1: 7 Rev. 9 3.6.9 Shut down wall hydrant valve #5156.
3.6.10 Shut down hydrant supplying water to wall hydrant and relieve pressure by loosening up the couplings at the hydrant.
3.6.11 Once the hose is depressurized, remove hose from hydrant and wall Valve
- 5156.
3.6.12 Disconnect each coupling and drain, clean and roll up hose and return to storage.
3.6.13 Place caps back on hydrant and wall hydrant valve #5156.
NOTE Loosen steamer cap on hydrant so it is hand tight.
3.6.14 Shut down wall hydrant #5155.
3.6.15 Shut down hydrant supplying water to valve #5155 and relieve pressure by loosening up the couplings at the hydrant.
3.6.16 Once the hose is depressurized, remove hose from hydrant and wall valve
- 5155.
3.6.17 Disconnect each coupling and drain, clean and roll up hose and return to storage.
3.6.18 Place caps back on hydrant and wall hydrant valve #5155.
NOTE Loosen steamer cap on hydrant so it is hand tight.
CROSS TIE INSTALLED BY:
DATE:
TIME:
INDEPENDENT VERIFICATION BY:
DATE:
TIME:
CROSS TIE REMOVED BY:
DATE:
TIME:
FIRE PROTECTION ENGINEER REVIEW:
SC-3.16.4.1: 8 Rev. 9 ATTACHMENT
ATTACHMENT 3 June 18, 2001 Email From NRC To RGE,
Subject:
Mail Envelope Properties (3B2E0082.8A6: 10: 35430)
Subject:
Creation Date:
From:
Created By:
Re: Loss of SW SDP 6/18/01 9:22AM Wayne Schmidt WLS@nrc.gov Recipients rge.com ThomasHarding (ThomasHarding@rge.com)
Post Office Files RiskQuestions.wpd MESSAGE Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
Size 6036 1232 Date & Time 06/18/01 09:18AM 06/18/01 09:22AM None Standard No None No Standard Route rge.com
From:
Wayne Schmidt To:
ThomasHarding@rge.com Date:
6/18/01 9:22AM
Subject:
Re: Loss of SW SDP Hi Tom - hope you had a good weekend.
Thanks for the last info.
We would like to gather the necessary furhter information this week, so that we can have a call with you, if necessary on Thursday or Friday. Please see the attached questions ( some of the answers overlap, but it was the easist way to make sure the bases were covered)..
I'll be out on Tuesday but in the rest of the week.
Thanks fcor your help.
SDP Questions Ginna SSDI
- 1.
Does the Ginna PRA assume the need for the crosstie of the cooling water from the fire main for total loss of service water scenarios? If so, was the assumption of the frequency of success the same as assumed in AFHDALTTD? If so, this does not appear appropriate since the operator must recognize (proceduralized) the loss of fire water and take actions to align the city water to the fire headers (proceduralized) and also recognize (not proceduralized) the need to connect the temporary supply hose (proceduralized).
- 2.
How would you estimate the Diagnosis HEP for the LOSW event, (given no procedure guiding the operator recognition) verse time for:
- 1.
The alignment of City/Fire water to the TDAFW pump of the need to complete Att 5.2?
- 2.
The alignment of City Water to SAFW?
- 3.
Was the Total mean HEP for the City water to fire water ever calculated? Has it been calculated now? If so what is it? (Please include the calculation).
- 4.
Relative to crediting feed and bleed for a LOSW - What does the current PRA assume?
We think that the SDP assumes no feed and bleed because the recirc capability would not be available. Does the PRA assume anything relative to the time dependance until the RWST reaches the point for swapover? Are there procedures in place for establishing a source of cooling water to the RHR Hxs, without SW?
- 5.
What is the current PRA core damage prob for LOSW? What would the LOSW core damage probability be given: (for each please include the sequences of interest and the assumed failure probabilities. If feed and bleed is credited please explain how.
- 1.
Inability to align Firewater to the TDAFW pump (given nominal failure probability for aligning city water to SAFW).
- 2.
Inability to align Firewater to the TDAFW pump and inability to align city water to SAFW.
ATTACHMENT 4 June 22, 2001 Email From RGE To NRC,
Subject:
NRC Questions
Mail Envelope Properties (3B338D35.177 : 16: 16759)
Subject:
Creation Date:
From:
Created By:
Recipients nrc.gov kplpo.KPDO FJA (Frank Arner)
JMT1 (James Trapp)
WLS (Wayne Schmidt)
Post Office kplpo.KPDO Files MESSAGE RiskQuestions.wpd LOSW2.xls LOSWI.xls Heade-"
Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
NRC Questions 6/22/01 2:07PM
<ThomasHarding@rge.com>
ThomasHarding@rge.com Route nrc.gov Size 384 22509 770560 1518080 990 None Standard No None No Standard Date & Time 06/22/01 02:07PM
From:
<ThomasHarding@rge.com>
To:
"Wayne Schmidt" <WLS@nrc.gov>, <JMT1@nrc.gov>, <FJA@nrc.gov>
Date:
6/22/01 2:24PM
Subject:
NRC Questions Attached are our responses to the previous questions.
Forwarded by Thomas Harding/NOG/RG&E on 06/22/2001 02:03 PM Mark Flaherty 06/22/2001 01:53 PM To: Thomas Harding/NOG/RG&E@RG&E cc:
Subject:
NRC Questions Here they are:
(See attached file: RiskQuestions.wpd)(See attached file: LOSW2.xls)(See attached file: LOSWI.xls)
SDP Questions Ginna SSDI In order to ensure that everyone is talking from the same page, here is a summary of the expected loss of service water (LOSW) scenario that will be used as a reference point in responding to the NRC questions.
A.
Given a LOSW, the plant would trip either automatically or manually within a few minutes due to loss of BOP related equipment, CCW to the RCPs, etc. The following equipment (as a minimum) will be assumed failed due to the loss of SW:
IA Compressors A, B, C. However, the service air compressor (normally cross tied to IA) and the diesel air compressor are available.
MDAFW Pumps A and B. However, the TDAFW pump will auto start on low SG level (shrink due to reactor trip) and the SAFW pumps will be available.
CCW high temperature alarms will result in tripping the CCW pumps. This will fail cooling to the RCPs (which will also be tripped) and the RHR heat exchangers (failing sump recirculation and RHR cooldown).
MFW pumps B.
Once the plant has tripped, the operators enter procedure E-0. It would be expected that SI conditions would not exist (nor a manual SI required) and operators would exit E-0 after step 4 and enter procedure ES-0.1.
C.
Upon exiting E-0, the STA would consult the Critical Safety Function Status Trees (CSFSTs) per EOP usage guides (procedure A-503.1) and the note prior to the first step in ES-0.1. Included within the CSFSTs is verification that there is 200 gpm total AFW flow and 5% level in at least one SG. The STA performs this verification approximately once every 10-20 minutes (step 3.2.10.3 of procedure A-503.1). At this point, there is also a shift briefing to discuss the plant status. It would be expected that the loss of SW would be discussed, but we will assume that this is not discussed for the purpose of this review.
D.
Procedure ES-0.1 provides instructions to the operators to stabilize the plant and bring it to hot shutdown conditions. There is a step to verify the number of operating SW pumps
(#5) and a continuous action step (#9) to verify SG level > 5%. The last step of the procedure requires the operators to consult plant staff to determine if cooldown is required and to go to procedure ES-0.2 for natural circulation cooldown (since there are no RCPs). It can be assumed that between the plant staff and licensed operators, that a decision would be made to limit the plant cooldown with no SW present since CCW and RHR are not available. However, it will be assumed that the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> run time with no SW lube oil cooling to the TDAFW pump will not be identified since this is only found in procedure ECA-0.0 (SBO).
E.
Procedure ES-0.2 instructs the operators to cooldown and depressurize the RCS using natural circulation. As mentioned above in D, it can be assumed that the plant cooldown would be limited with no SW available. However, it will now be assumed that the TDAFW pump fails after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of operation with no SW cooling for lube oil. Since AFW and maintaining SG level is a basis for providing natural circulation, it would be expected that operators would be monitoring it closely. The STA would also be monitoring these as part of the CSFSTs once every 10-20 minutes. Between these and the expected control board alarms, operators would transition to FR-H.1 upon loss of the TDAFW pump.
F.
Procedure FR-H.1 instructs the operators to restore feedwater flow to the SGs first by preferred AFW, then by MFW, then by SAFW. Preferred AFW and MFW will be
assumed unavailable such that only SAFW can be used. EOP Attachment 5.1 instructs the operators to align SAFW taking suction from SW. Procedure ER-AFW.1 provides instructions on how to use alternate suction sources (e.g., city and fire water); however, there is no direct links to ER-AFW.1 from FR-H.1 and Attachment 5.1 other than CST level < 5 feet. Regardless, the operators know that SW is unavailable and have been trained on the use for ER-AFW.1 for similar type circumstances. That is, ER-AFW.1 is considered to be an Abnormal Operating Procedure (AOP) that is referenced by the EOP series of procedures. Operators are trained and expected to utilize AOP type of procedures as needed in support of EOP implementation. Also, the minimum CST level specified in LCO 3.7.6 is based on providing sufficient inventory for the TDAFW pump for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> post trip in accordance with NUREG-0737, item II.E.1.1. As such, the operators would be expected to be procedurally directed into ER-AFW.1 from low CST level at about the same time that the TDAFW pump would fail due to insufficient lube oil cooling.
G.
If AFW, M FW, and SAFW cannot be implemented by FR-H.1, then the operators are instructed to use the condensate system or implement feed and bleed. The condensate system has no dependancies on SW, but does require depressurizing the SGs which could be accomplished using ARVs especially given 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of successful TDAFW operation. Feed and bleed occurs until necessary subcooling margin is obtained such that the SI pumps can be stopped and the PORVs closed. At this time, the plant would go to normal RHR shutdown cooling (requires SW), sump recirculation (requires SW), or stabilize on AFW that has been restored. Assuming a SI flowrate of 500 gpm (each pump is designed for 350 gpm and given the initial lower decay heat levels) and 300,000 gallons of RWST inventory, the need to be on RHR or AFW would not occur before 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />. It can be expected that either SW, the TDAFW pump, or SAFW would be recovered within this time frame. However, the PSA model assumes that recirculation capability is required (i.e., there is no credit for this recovery).
- 1.
Does the Ginna PRA assume the need for the crosstie of the cooling water from the fire main for total loss of service water scenarios? If so, was the assumption of the frequency of success the same as assumed in AFHDALTTD? If so, this does not appear appropriate since the operator must recognize (proceduralized) the loss of fire water and take actions to align the city water to the fire headers (proceduralized) and also recognize (not proceduralized) the need to connect the temporary supply hose (proceduralized).
As indicated in PSA Final Report, Appendix F, Table F-4, event AFHFDALTTD is only credited for SBO scenarios (i.e., scenarios where procedure ECA-0.0 is entered). All other scenarios use a value of 1.0 for using fire water to support the TDAFW pump.
- 2.
How would you estimate the Diagnosis HEP for the LOSW event, (given no procedure guiding the operator recognition) verse time for:
- a.
The alignment of City/Fire water to the TDAFW pump of the need to complete Att-5.2?
- b.
The alignment of City Water to SAFW?
The diagnosis for alignment of fire water to the TDAFW pump (AFHFDALTTD) and city water to SAFW (AXHFDCITYW) was based on the following:
- a.
AFHFDALTTD - Cues to perform this action would only be available upon entering ECA-0.0, Step 8.d. All other scenarios do not credit this action (i.e.,
failure probability of 1.0).
- b.
AXHFDCITYW - Cues to perform this action would be from one of the following:
(1) low CST level - found on foldout page of all EOPs, (2) Step 13.a RNO of Procedure FR-C.1 for inadequate core cooling if SG level cannot be maintained >
5%, (3) Step 7 of Procedure FR-H.1 for inadequate heat sink if SAFW cannot be aligned to SW. Note that for the last item, there is no direct procedural guidance.
However, as described in item F of the event summary, operators are expected to utilize AOPs like ER-AFW. I in a situation like this. The calculation of this value was previously provided to the NRC and assumes that the operator had 20 minutes of diagnosis available. With 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of successful TDAFW operation, this diagnosis time would be much longer.
- 3.
Was the Total mean HEP for the City water to fire water ever calculated? Has it been calculated now? If so what is it? (Please include the calculation).
No HEP for this event has ever been calculated, nor is there any intention of generating one at this time. Instructions to perform this step are not contained within the EOP and AOP series of procedures (i.e., they are in other plant testing procedures). However, this activity is performed during testing and maintenance of the fire water systems and is called out in the TRM for when both fire pumps are inoperable (i.e., establish a backup fire water system). That is, operators are aware of this capability.
- 4.
Relative to crediting feed and bleed for a LOSW - What does the current PRA assume? We think that the SDP assumes no feed and bleed because the recirc capability would not be available. Does the PRA assume anything relative to the time dependance until the RWST reaches the point for swapover? Are there procedures in place for establishing a source of cooling water to the RHR Hxs, without SW?
The PSA utilizes a single transient event tree which contains, among other transients, the LOSW event (see PSA Final Report Figure 5-1). For the feed portion of feed and bleed, top event UH1 on the figure (High Pressure Injection) contains the logic for gate SR500, FAILURE TO DELIVER FLOW FROM 1 OF 3 SI PUMPS TO THE RCS DURING RECIRC. Since no recovery of SW is credited (as described in the event summary, item G), feed and bleed is not success for a LOSW event. However, since it would take over 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> to deplete the RWST, it could be postulated that the SW or AFW system would be recovered, or even the RWST refilled. There is no procedure which establishes an alternate source of cooling to the RHR HXs, primarily due to the number of AFW pumps.
- 5.
What is the current PRA core damage prob for LOSW? What would the LOSW core damage probability be given: (for each please include the sequences of interest and the assumed failure probabilities. If feed and bleed is credited please explain how.)
- a.
Inability to align Firewater to the TDAFW pump (given nominal failure probability for aligning city water to SAFW).
- b.
Inability to align Firewater to the TDAFW pump and inability to align city water to SAFW.
Three LOSW scenarios were solved as described below. In no instance is credit for feed and bleed taken.
LOSW as currently addressed within the PSA model - The attached cutset file (LOSW1.XLS) shows a of CDF 3.035E-06 with risk dominated by transients with no AFW available. Note that event AFHFDALTTD is only found in combination with a SBO event. Also, AXHFDCITYW is not found in the cutsets. This is due to the fact that there is already a human error event of failing to start SAFW per EOP steps (AXHFDSAFWX) within the models. For LOSW, this event also includes failure to align city water since no SW is available at the outset.
Consequently, event AXHFDSAFWX was increased by the necessary factor to result in a failure probability of 1.OE-02 similar to AFHFDALTTD.
LOSW with no credit for aligning Firewater to TDAFW-this is the same as the first sequence since event AFHFDALTTD is only credited for SBO cutsets.
LOSW with no credit for aligning Firewater to TDAFW nor city water to SAFW-If no credit is taken for TDAFW and the SAFW systems, then the CDF is equivalent to the LOSW frequency, or 2.OOE-04/yr (LOSW2.XLS). However, this scenario is not considered credible due to the reasons described above for the operators treatment of ER-AFW.1 as a AOP which is entered as necessary in the EOPs.
Also, if operators failed to align city water to SAFW in FR-H.1, they would go to feed and bleed. Once this failed due to lack of RWST inventory and ability to go onto RHR, the core would heat up and the operators would enter FR-C.1. This procedure has specific guidance to enter ER-AFW.1 in step 13.a RNO for when SG level is < 5% and 200 gpm of AFW cannot be established. Finally, the use of the condesate system has not been considered.
Cutsets with Descriptions Report
@POWER1 = 3.03E-06 D:ICAFTA-06/22/2001 13:45 Inputs Description 1 TI0000SW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG -TRANSIENT EVENT 2 TI00OOSW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress duoing loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG - TRANSIENT EVENT 3 TIOOQSW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Resuts in SI Conditions (Seat LOCA)
CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZ001RCP NO RCP SEAL COOLING FOR> 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 4 TI0000SW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
CVMMRCPIFP NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZO01RCP NO RCP SEAL COOLING FOR + 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 5 T10000SW Total Loss of Service Water AXXVN09728 3 way valve 9728 fails to operate NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 6 TI00OOSW Total Loss of Service Water AXXVN09728 3 way valve 9728 fails to operate NOSEO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG -TRANSIENT EVENT 7 TI000OSW Total Loss of Service Water AXMMSAFWPC Failure of SAFW Pump 1C train AXMMSAFWPD Failure of SAFW Pump 1D Train NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 8 TI0000SW Total Loss of Service Water AXMMSAFWPC Failure of SAFW Pump IC train AXMMSAFWPD Failure of SAFW Pump 1D Train NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG - TRANSIENT EVENT 9 Ti0000SW Total Loss of Service Water ACAA50_5OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A)
ACAZDLOSPI Failure to Restore Offsite Power Within I Hour ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of Al Off-Site Power Following Reactor Trp ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure ofAC Train B AFAX1TDAFW TAG - TDAFW Pump operates successfully DG1ANOTRUN FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DGt BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 POF PLANT CAPACITY FACTOR SBO TAG - STATION BLACKOUT SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run SWrODG TAG - SW Lost to DG (cooling) 10 Ti0000SW Total Loss of Service Water ACAA5050A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACAZDLOSPI Failure to Restore Offsge PowerWithin I Hour ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Tdp ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B AFAX1TDAFW TAG - TDAFW Pump operates successfully DG1ANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PCF PLANT CAPACITY FACTOR SBO TAG - STATION BLACKOUT SEQUENCE SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
SWTODG TAG - SW Lost to DG (cooling) 11 T10000SW Total Loss of Service Water AXTMSAFSGA SAFW TRAIN C TO S/G A O.OS. DUE TO T/M AXTMSAFSGB SAFW TRAIN D TO S/G B O.S. DUE TO T/M NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 12 TIOOOOSW Total Loss of Service Water NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZO00515N Motor-Operated Valve 515 ts Not Closed Due to PORV Leakage RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min RCRZT0431C PORV PCV-431C Falls To Reseat After Steam Relief SLO TAG - SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 13 TIoOOOSW Total Loss of Service Water NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage RCHFDPLOCA Operators Fail To Close PORV Block Valve (510/516) To Terminate LOCA W/n 3 Min RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief Rate Exposure Event PreoProbability 1 1.00E+O0 1.06E-06 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1_00E+00 1 1.00E+00 8.76E-07 Sl1E-03 S.19E-03 I 1.93E+00 1 1.00E+00 0.88 8.76E-01 1.001-04 1.OOE-04 1 1.00E+0O I 1.00E+00 1.59E-07 1 1.000E00 1.50E-03 1.00E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 I 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 I.00E+00 1.32E-07 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 I 1.000E00 1 1.00E+00 1.00E-04 I.00-O04 1 1.00E+00 1.06E-07 1.00E-03 1 1.000-03 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+0O 1 1.000E00 8.76E-08 1-00E-03 1 1.00E-03 1 1.00E+00 0.88 8.76E-01 1-0OE-04 1.00E-04 1 1.00E+00 1 1.00E+00 0.04E-08 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 4.59E-08 0.02 2.290E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 3.47E-08 0.83 8.25E.01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 9.97E-01 I 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1_00E+00 2.87E-08 0.83 8.20E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.78E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 I 1.00E+00 2.81E-08 0.02 1.67E-02 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 I 1.00E+00 2.50E-00 1 1.00E000 0.88 8.76E-01 0.97 9.67E-01 0.00 0.00E.02 5.00E-03 1 5.00E-03 1 1.00E+00 1.21E-04 1.21E-04 1 1.000+00 1 1.00E+00 2.56E-08 1 1.00E+00 0.88 8.76E-01 0.97 9.87E-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 LPIQM. YL S
SLO TAG - SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 14 TI000SSW Total Loss of Service Water AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO TiM AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TO T/M NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG - TRANSIENT EVENT 15 TISOOOSW Total Loss of Service Water NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZD00515N Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/n 3 Min RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief SLO TAG - SMALL LOCA SEQUENCE SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 16 TI0000SW Total Loss of Service Water NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/ln 3 Min RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief SLO TAG - SMALL LOCA SEQUENCE SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 17 TI000SW Total Loss of Seara/e Water ACB2FIBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Firi Events For Stress)
FSAZCORRO3 Condction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1B SW Pump B in maintenance TRANSX TAG - TRANSIENT EVENT 18 T10000SW Total Loss of SeOvsoe Water AXCCSSAFWA Common cause falure of SAFW Pumps IC and 1D to start NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 19 TI0000SW Total Loss of Service Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWMMOSWPAS FAILURES OF SW PUMP A TO START SWTMPUMPIC SW Pump C In maintenance TRANSX TAG - TRANSIENT EVENT 20 TI0000SW Total Loss of Searvce Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI00OOSW and Some Fire Events For Stress)
FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loso of SWlo NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start TRANSX TAG - TRANSIENT EVENT 21 TI000OSW Total Loss of Service Water ACB2FIBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI000OSW and Some Fire Events For Stress)
FSAZCORRS3 Correct/on Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start TRANSX TAG - TRANSIENT EVENT 22 TIOOSW Total Loss of Service Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TI000OSW and Some Fire Events For Stress)
FSAZCORRO3 Correct/on Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWMMOSWPCS FAILURES OF SW PUMP C TO START SWTMPUMPIA SW Pump A in maintenance TRANSX TAG - TRANSIENT EVENT 23 TI00OGSW Total Loss of Service Water AXCCDMOVNB Common cause failure of MOVs 9701A and 9701B to throttle flor NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 24 TI0000SW Total Loss of Service Water AXCCSSAFWA Common cause failure of SAFW Pumps IC and 1D to start NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG - TRANSIENT EVENT 25 TIOOOOSW Total Loss of Service Water AXHFLSAFWA Failure to restore SAFW Pump Train 1C to service pest test/mault AXMMSAFWPD Failure of SAFW Pump 1 D Train NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 26 TIO00OSW Total Loss of Service Water AXHFLSAFWB Failure to restore SAFW Pump Train 1 D to service post test/moist AXMMSAFWPC Failure of SAFW Pump IC train NOSBO TAG. NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 27 TIOGOOSW Total Loss of Searice Water AXCCDMOVNB Common cause failure of MOVs 9701A and 9701B to throttle flow NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR)
TRANSX TAG -TRANSIENT EVENT 1 1.00E+00 1.21E-04 1.21E-04 I 1.00E+00 1 1.00E+00 2.17E-08 0.02 1.67E-02 0.01 1.48E-02 1 1.0DE+00 0.88 8.76B-01 1.00E-04 1.00E-04 I 1.0OE+OO 1 1_00E+00 2.12E-08 I 1.0DE+00 0.88 8.76E-01 0.97 9.87E-01 0.05 B.SOE-02 5.00E-03 1 5.O0E-03 I 1.00E+00 1.00E-04 1.00E-04 1 1,00E+00 1 I.002+00 2.12E-08 1 1.00E600 0.88 8.76E-01 0.97 9.67E-01 0.05 5.0012-02 5.0BE-03 I 5.00E-03 1 1.OGE+00 1.00E-04 1.00E-04 1 1G.00E+O I 1.OGE+00 1.16E.O8 1.01E-06 I
8.85E-03 I 1.00E+O0 5.19E-S3 5.19E-03 I 1.93E-00 I 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.00E+00 1 1.OOE+00 9.2gE-0g 8.79E-O5 8.79E-O5 I 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E+00 I 1.00E+O0 9.05E-09 1.01E-06 I
8.85E-03 1 1.00ES00 5.19E-03 5.19E-03 I 1.93E+00 1 1.OOE+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 8.84E-09 1.01E-06 1 8.85E-03 1 1.OOE÷00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 I 1.00E+O0 1 1.00E+00 8.84E-09 1.01E-06 1 8.85E-03 1 1.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 1.14E-C4 1.14E-04 I 1.00E+00 1 1.00E+00 7.96E-09 1.01E-06 1 8.850-03 1 1.00E+00 5.19E-03 5.19E-03 I 1.93E+00 1 1.00E600 0.88 8.76E-01 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 1 1.00E+00 7.70E609 7.28E-05 7.28E-05 1 1.00E+00 088 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 7.70E-09 8.70E-05 8.79E-05 1 1.00E+00 0a88 8-76E-01 1.0GE-G4 1.00E-04 1 1.00E+00 1 1. 0E÷00 7.27E-09 3.00E-03 3.00EO03 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 7.25E-09 3.00E-03 3.00E-O3 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.0XE+00 1 1.00E+00 6.38E-09 7.28E-05 7.28E-05 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00
28 TI0000SW Total Loss of Service Water ACAA1000X FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
ACAZDLOSP1 Failure to Restore Offste Power Within 1 Hour ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B AFAXITDAFW TAG - TDAFW Pump operates successfully DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DG1BNOTRUN FLAG-DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PCF PLANT CAPACITY FACTOR SBO TAG - STATION BLACKOUT SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run SWTODG TAG - SW Lost to DG (cooling) 29 TIOOSOSW Total Loss of Serioe Water AXHFLSAFWA Failure to restore SAFW Pump Train 1 C to service post test/maint AXMMSAFWPD Failure of SAFW Pump 1D Train NOSED TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG - TRANSIENT EVENT 30 TI0000SW Total Loss of Service Water AXHFLSAFWB Failure to restore SAFW Pump Train 1D to service post test/maint AXMMSAFWPC Failure of SAPW Pump lC train NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG - TRANSIENT EVENT 31 TI0000SW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
CVMMRCPALP NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER NOSBE TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZOIRCP NO RCP SEAL COOLING FOR > 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 32 T10000SW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
CVMMRCPBLP SEAL LEAKOFF PATH FROM ROP B OBSTRUCTED NOSBE TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZOO1RCP NO RCP SEAL COOLING FOR + 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 33 TI0000SW Total Loss of Service Water AXHFLSAFWB Failure to restore SAFW Pump Train 1 D to service post test/maimt AXTMSAFSGA SAFW TRAIN C TO SIG A O.O.S. DUE TO TIM NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 34 TIO0OOSW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
CVMMRCPAFP NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZ001RCP NO RCP SEAL COOLING FOR v I HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 35 TI0000SW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
CVMMRCPBFP NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZO01RCP NO RCP SEAL COOLING FOR 5 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 36 TIOiOOSW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In St Conditions (Seal LOCA)
CVPPJCVCOM Common CVCS Piping Ruplure NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZ001 RCP NO RCP SEAL COOLING FOR u 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAS SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 37 TI000OSW Total Loss of Service Water ACAA100_OX FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
ACAZDLOSPI Failure to Restore Offshe Power Within 1 Hour ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B AFAX1TDAFW TAG - TDAFW Pump operates successfully DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PCF PLANT CAPACITY FACTOR SBO TAG - STATION BLACKOUT SEQUENCE SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
SWTODG TAG - SW Lost to DG (cooling) 38 TIS00OSW Total Loss of Service Water AXHFLSAFWA Failure to restore SAPW Pump Train 1 C to service post test/maimt AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TO TIM NOSBE TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run TRANSX TAG - TRANSIENT EVENT 39 TI0000SW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
CVMMRCPALP NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZ001RCP NO RCP SEAL COOLING FOR 5 1 HOUR SEALLOCA TAG - TRANSIENT INDUCED SEAL LOCAs SSLO TAG - SMALL SMALL LOCA SEQUENCE SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 40 TiOOitOSW Total Loss of Service Water AAAATRANSI TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
CVMMRCPBLP SEAL LEAKOFF PATH FROM RCP B OBSTRUCTED NOSBO TAG - NO STATION BLACKOUT 1 1.00E+00 6.0E-09 0.14 1.44E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 I
9.97E-01 I
9.97E-01 0.88 8.76E-01 I 1.0iE+00 1.21E-04 1.21E-04 I I.0OE+00 1 1.00E+00 6.03E-09 3.OBE-03 3.00E-03 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 6.01E-09 3.00E-03 3.001-03 0.02 2.28E-02 I 1.00Eu00 048 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 5.685E-09 1 1.00E+00 5.34E-05 5.34E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.0OE+00 1.21E-04 1.21E-04 1 1.00E+00 5.65E-09 1 1.00E+00 5.34E-05 5.34E-05 1 100E+00 0-88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 5.30E-09 3.00E-03 3.00E-03 0.02 1.67E-02 1 1.0OE÷00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E+00 1 1.00E+00 5. 16E-09 1 1.00E+00 4.88E-05 4.88E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 5.16E609 1 1.00E+00 4.88E-05 4.88E-05 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 8.02E-09 1 1.00E+00 1.98E-06 24 4.75E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 5.02E-09 0.14 1.44E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1-006+00 I 1.00E+00 1
9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E÷00 4.69E-09 3.00E-03 3.00E-03 0.01 1.48E-02 1 1.00E+00 06.8 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 4.68E-09 1 1.00E+00 5.34E-05 5.34E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 I 1.00E+00 4.68E-09 I 1.00E+00 5.34E-05 6.34E-05 I 1.00E+00
PCF RCAZO01RCP SEALLOCA SSLO SWCXXSUCTI 41 TI0000SW FSTMFCITYW NOSBO PCF SWCCIPUMPSR TRANSX 42 T10000SW AXHFLSAFWB AXTMSAFSGA NOSBO PCF S*WXXSUCTI TRANSX 43 T10000SW AAAATRANSI CVMMRCPAFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI 4TI0000SW AAAATRANSI CVMMRCPBFP NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCXXSUCTI 45 "10000SW AAAATRANSI CVPPJCVCOM NOSBO PCF RCAZ001RCP SEALLOCA SSLO
- WCXXSUCTI 46 TIOOOOSW AXHFLSAFWA AXTMSAFSGB NOSBO PCF SWCXXSUCTI TRANSX 47 TI0000SW FSTMFCITYW NOSBO PCF SWCXXSUCTI TRANSX 48 T10000SW AAAATRANSI CVMMRCPIFP NOSBO PCF RCHFD0ORCP SEALLOCA SSLO SWCCIPUMPSR 49 TI0000SW AAAATRANSI ACAA50_5OA ACLOPNOSI2 ACLOPRT751 ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DG18NOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 50 T10000SW AAAATRANSI ACAAS050A ACLOPNOSI2 ACLOPRTALL ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DG1BNOTRUN NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 51 T7100OSW AAAATRANSI CVMMRCPIFP NOSB03 PCF RCHFDOORCP SEALLOCA SSLO SWCa3SUCTI 52 T10000SW ACAAS_50A ACLOPNOSI2 ACLOPRT767 PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG O-TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water City Water Supply to Yard Fire Loop Inoperable TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water Failure to restore SAFW Pump Train 1D to service post test/maint SAFW TRAIN C TO S/G A O.OS. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in 31 Conditions (Seal LOCA)
NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR 5 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Common CVCS Piping Rupture TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Failure to restore SAFW Pump Train 1C to service post test/moaint SAFWTRAIN D TO S/G B O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water City Water Supply to Yard Fire Loop snoperable TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG -Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 751 Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR 5 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - BW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKCT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-Site Power Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Resuots in SI Conditions (Seal LOCA)
NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Trip RCPS After Loss of Support Systema TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 50050 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Less of Offsite Circuit 767 Foilowing Reactor Trip 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 00E-04 1.00E-G4 I 1.00E+00 4.46E-09 4.22E-05 4.22E-05 1 1.00E+00 0.88 8076E-01 1.21E-04 1.21E-04 1 1.00E*00 1 1.00E+00 4.39E-09 3.OOE-03 3.00E-03 0.02 1.67E-02 1 1.00E+00 0.88 8.70E-01 1.00E-04 1.00E04 1 1.00Eu00 1 1.00E+00 4.27E-09 1 1.001+00 4.88E-05 4.88E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 I 1.00E+00 1.00E-04 1.00E-04 I 1.00E+00 4.27E-09 1 1.00E+00 4.88E-05 4.88E-05 1 1.00E+00 0088 8.76E-01 1 t.00E+00 I 1.OOE+00 I 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 4.16E-09 1 1.00E+00 1.98E-06 24 4.75E-05 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 I 1.00E+00 I 1.,OE+00 1.00E-04 1.00E-04 1 1.00E+00 3.89E-09 3.00E-03 3.0OE-03 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 1.OOE-04 1.00E-04 1 1 OOE+00 1 1.05E+00 3.70E-09 4.22E-05 4.22E-05 1 1.00E-00 0.88 &.78E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 2.56E-09 1 1.O0E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 0.02 1.61E-02 I 1.00E+00 I 1.BOE+00 1.21E-04 1.21E-04 1 1.00E+00 2.52E-09 1 1.00E+00 0.83 8.25E-01 0.0 5.00E-01 2-12E-03 2-12E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.002+00 I t.00E÷00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 2.50E-09 I 1.00E+00 0083 8.25E-01 0.5 5.00E-01 2.10E-03 2.1OE-03 1 1.00E÷00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+00 0.88 8.7BE-01 1 1.00E+00 1 1.00E+00 1 1.00Eu00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00Eu00 2.12E-09 1 1.006+00 1.50E-03 1.50E-03 1 1.OOE+00 0.88 8.76E-01 0.02 1.81E-02 1 1.002E+00 1 1.00En00 1.00E-04 1.00E-04 1 1.00E+00 2.11E-09 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03
ACTRAINA AXMMSAFWPD DGIANOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 53 TIOOOOSW ACAA50.50A ACLOPNOSt2 ACLOPRT751 ACTRAINB AXMMSAFWPC DG1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 54 TIOOOOSW AXCCFSAFWA NOSBO PCF SWCCIPUMPSR TRANSX 55 TI0000SW ACAASO_50A ACLOPNOSI2 ACLOPRTALL ACTRAINA AXMMSAFWPD DG1ANOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 56 TIOOOOSW ACAASO_50A ACLOPNOSI2 ACLOPRTALL ACTRAINB AXMMSAFWPC DG1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 57 TI0000SW AAAATRANSI ACAA50_50A ACLOPNOS12 ACLOPRT751 ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DG1BNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 58 TI0000SW A.AATRANSI ACAASO_50A ACLOPNOSI2 ACLOPRTALL ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DGoBNOTRUN NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 59 TI0000SW ACB2FIBS18 ACTRAINA AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWMMOSWPBS SWTMPUMP1 D TRANSX 60 TIOOOOSW ACAA50.50A ACLOPNOSI2 ACLOPRT767 ACTRAINA AXMMSAFWPD DGIANOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 61 TI0000SW ACAAS050A ACLOPNOSI2 ACLOPRT751 ACTRAINB AXMMSAFWPC DG1 BNOTRUN NOSBO TAG - Failure of AC Train A Failure of SAFW Pump ID Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offste Circuit 751 Following ReactorTop TAG - Failure of AC Train B Failure of SAFW Pump IC train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water Common cause failure of SAFW Pumps 1C and 1D to run TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 797 TO BUS 12A)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of AN Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Failure of SAFW Pump 1D Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG-OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO S CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Top TAG - Failure of AC Train B Failure of SAFW Pump IC train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditioos (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 129, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG -CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG o
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Operators Fail to Correctly Align SAFW (Comncted for TI000OSW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP B TO START SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsoe Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Failure of SAFW Pump 1D Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to Do (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following ReactorTop TAG - Failure of AC Train B Failure of SAFW Pump IC twin FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 TAG - NO STATION BLACKOUT 1 1.OOE+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.OE÷00 1 1.09E+00 1 1.00)E00 2.11E-09 0.83 8.25E-01 0,5 5.00E-01 2.12E-03 2.122-03 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 I 1.09E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 2.11E-09 1.99E-05 1.99E-05 1 1.00E+00 0.88 8.7SE-O1 1.21E-04 1.21E-04 1 1.OOE÷00 1 1.0)E+00 2.09E-09 0.83 8.25E-01 0.5 5.02E-01 2.10E-03 2.10E-03 1 1.009+00 0.02 2.29E-02 1 9.97E-01 I 1.50E+00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E+50 I 1.00E+00 1 1.00E+00 2.09E-09 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E÷00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 2.09E-09 1 1.00E+00 0.83 8.25E-01 0.5 5.00-E01 2.12E-03 2.12E-03 1 1.50E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+0 0.88 8.76E-01 1 1509E+00 1 1.00E+00 I 1.00E+00 1.0OE-04 1.00E-04 1 1.00E+00 1 1.00E+00 2.07E-09 I 1.00E+00 0.83 8.25E-01 0.5 5.009-01 2.10E-03 2.10E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.009+00 I 1.00E+50 1.00E.04 1.09E-04 I 1.00E+50 I 1.00E+00 1.82E-09 1.01E-06 1 8.05E-03 1 1.50E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.50E+00 0.88 8.76E-01 3.22E-03 3.28E-03 7.15E-03 7.15E-03 1 1.00E+00 I 1.00E+00 1.75E-09 0.83 8.25E-01 0.5 5.50E-01 2.12E-03 2.12E-03 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 1 1.09E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+50 I 1.09E+50 1 1.50E+00 1.75E-09 0.83 8.25E-01 0.5 5.50E-01 2.12E-03 2.12E-03 1 11.00E+0 0.02 2.29E-02 1 9.97E-01 1 1.50E+00
PCF SWC)XSUCTI SWTODG TRANSX 62 Ti0000SW AXCCFSAFWA NOSBO PCF SWCXXSUCTI TRANSX 63 T10000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPIFP NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWMOOSWPDS SWTMPUMP1 B 64 TI00OOSW ACAA50_0A ACLOPNOSI2 ACLOPRTALL ACTRAINA AXMMSAFWPD DGIANOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 65 TI0000SW ACAA50_50A ACLOPNOSI2 ACLOPRTALL ACTRAINB AXMMSAFWPC DGIBNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 66 T10000SW AAAATRANSI CVCCMPFABC NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWCCIPUMPSR 67 T10000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWMMOSWPAS SWTMPUMP1C 68 T10000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCAZO1RCP SEALLOCA SSLO SWCCPUMPSS 89 T10000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPIFP NOSB00 PCF RCAZ0B1RCP SEALLOCA SSLO SWCCPUMPSS 70 T10000SW AAA*TRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWMMOSWPCS SWTvIMPUMP1A 71 T10000SW AAAATRANSI CVCCMPFABC NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI 72 TIOOSW ACB2FIBS18 ACTRAINA AXHFDSAFWX PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water Common cause failure of SAFW Pumps 1C and 1D to run TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP D TO START SW Pump B in maintenance Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Failure of SAFW Pump 10 Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train B Failure of SAFW Pump 1C train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1B AND 17 TAG. NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Whicih Eventually Results in SI Conditions (Seal LOCA)
COMMON CAUSE FAILURE OF THE CHARGING PUMPS TO RUN TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Servrce Water Pumps To Run Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR u 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
COMMON CAUSE FAILURE OF THE CHARGING PUMPS TO RUN TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG. TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress) 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E-00 1 1.00E-00 1.75E-09 1.99E-05 1.99E-05 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 I 1.00E>00 I 1.00E+00 1.74E-09 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 I 1.00E+n0 I 1.00E+00 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.00E+00 1.73E-09 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E-00 0.02 2.29E-02 I 9.97E-01 1 1.0OE+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.73E-09 0.83 8.25E-01 0.5 5.00-E01 2.10E-03 2.10E-03 1 1_00E800 0.02 2.29E-02 I
9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00o-04 1.00E-04 1 1_00E+00 1 1.00E+00 1 1.00E-00 1.44E-09 I 1.00E+00 1.36E-05 1.36E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00>E00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1.36E-09 1 1.0OE+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 1 1.008E00 0.88 8.76E-01 1 1.00E+00 1 1.0OE+00 I 1.00E+00 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 1 33E-09 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.001+00 1.50E-03 1.50E-03 1 1.00E÷00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.14E-04 1.14E-04 1 1.001+00 1.33E-09 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 1 1.001+00 0.88 8.76E-01 1 1.00E+00 1 1.00>E00 I 1.00E+00 1.14E-04 1.14E-04 1 1.00E+00 1.20E-09 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.501-03 1 1.00E+00 0.88 8.76E-01 1 1.00E800 1 1.00E+00 1 1.00E+00 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 1.19E-09 I 1.00E+00 1.36E-05 1.36E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+0O 1.19E-09 1.01E-06 1 8.85E-03 1 1.00E+00 5.18E-03 5.19E-03
FSAZCORRO3 NOSBO PCF SWAASWPICR SWCVC04603 SWVTMPUMPIB TRANSX 73 T10000SW ACE2FIBS18 ACTRAINA AXXVN09728 NOSBO PCF SWMMOSWPDS SWTMPUMP1E TRANSX 74 I50000SW NOSBO PCF RCAZDO0515N RCMVC0051 5 RCRZT0431 C SLO SWCCIPUMPSR TLSTRANS 75 TIOOOOSW NOSEO PCF RCAZD00516N RCMVC00515 RCRZT00430 SLO SWCCIPUMPSR TLSTRANS 78 TIOOOOSW AXMMSGBSAF AXTMSAFSGA NOSBO PCF SWCCIPUMPSR TRANSX 77 TIOOOOSW AXHFLSAPWA AXHFLSAFWB NOSBO PCF SWCCIPUMPSR TRANSX 78 TI000OSW NOSBO PCF RCAZDD0515N RCMVC00515 RCRZT0431C SLO SWCXXSUCTI TLSTRANS 79 T10000SW NOSBO PCF RCAZD00516N RCMVCO0515 RCRZTO0430 SLO SWCXXSUCTI TLSTRANS 80 TI0000SW AXMMSGBSAF AXTMSAFSGA NOSBO PCF SWCXXSUCTI TRANSX 81 TI000OSW ACE2FIBS17 ACTRAINB AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWPIBR SWCVC04802 SWTMPUMP1C TRANSX 82 TIOOOOSW NOSBO PCF RCAZDO0515N RCCCFPORVC RCHFDPLOCA SLO SWCCIPUMPSR TLSTRANS 83 TI000OSW NOSBO PCF RCAZD00516N RCCCFPORVC RCHFDPLOCA SLO SWCCIPUMPSR TLSTRANS 84 T10000SW ACB2FIBS17 ACTRAINB AXXVN09728 NOSEO PCF SWMMOSWPAS SWTMPUMP1C TRANSX 85 TI0OOSW MLO PCF Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWO1 C Is In Operation Service Water Pump PSWsIC Discharge Check Valve 4603 Fails To Close On Demand SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP D TO START SW Pump E In maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage MOV 515 fails to close PORV PCV-431 C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage MOV 515 fails to close PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Failure of SAFW injection line to SIG B SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water Failure to restore SAFW Pump Train IC to service post testlmaint Failure to restore SAFW Pump Train 1D to service post test/mrint TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage MOV 515 fails to close PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage MOV 515 fails to close PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Failure of SAFW injection line to S/G B SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Operators Fail to Cotrectly Align SAFW (Corredced for T1000OSW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWOE B Is In Operation Service Water Pump PSWOlB Discharge Check Valve 4602 Fails To Close On Demand SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage PORVs FAIL TO CLOSE (CCF)
Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage PORVs FAIL TO CLOSE (CCF)
Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B 3 way salve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - MEDIUM LOCA SEQUENCE PLANT CAPACITY FACTOR 1 1.93E+00 1 1.00EQ00 0.88 8.76E-0l 0.58 5.79E-01 5.84E-04 1 5.84E-04 0.05 4.55E-02 1 1.O0E+0O I 1.00E+00 1.16E-09 1.01E-06 1
8.86E-03 I 1.O0E+0O 1.0E-03B 1 l10E-03 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.00E+00 I 1.00E+00 1.14E-09 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 2.22E-03 1 2.22E-03 S.DOE-G3 1 5.00E-03 1 1,001E00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1.14E209 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 2.22E-03 1 2.22E-03 5.OE-03 1 5.00E-03 1 1.00E+00 1.21E-04 1.21E-04 1 1.SOE+00 1 1.002+00 1.13E-O9 6.39E-04 8.39E-04 0.02 1.67E-02 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E200 1 1.00E+00 9.52E-10 3.0OE-03 3.00E-03 3.00E-03 3.00E-03 I 1.00E+00 0.88 8.78E-01 1.21E-04 1.21E-04 1 1.00E÷00 1 1.00E+00 9.41E-10 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 2.22E-03 1 2.22E-03 5.00-E03 1 5.00E-03 1 1.OSE÷00 1.OoE-04 1.00E-04 I 1.00E+00 1 1.0OE+00 9.41E-10 1 1.SOE+00 0.88 8.76E-01 0.97 9.67E-01 2.22E-03 I 2.22E-03 5.0E-03 1 5.O0E-03 1 1.00+O00 1.00E-04 1.00E-04 I l.OGE+00 1 1.00E+00 9.34E-10 6.39E-04 6.39E-04 0.02 1.67E-02 1 1.00E+00 0.88 8.76E-01 l.OOE-04 1.00E-04 1 1.00E+00 1 1.00E+00 9.33E-t0 1.01E-06 1 f.85E-03 1 1. OE+00 5.19E-03 5.19E-03 1 1.93E+00 I 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 5.84E-04 1 5.84E-04 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 9.15E-10 1 1.00E+OO 0.88 8.76E-01 0.97 9.67E-01 1.79E-04 1.79E-04 0.05 500E2-02 1 1.00E00 1.21E-04 121E-04 I 1.00E+00 1 1.00E*00 9.15E-10 1 1.00E+00 0.88 8.76E-01 0.97 9.87E-01 1.79E-04 1.79E-04 0.05 5.00E-02 1 1.002+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 9.05E-10 1.01 E-06 1 8.85E-03 1 1.00Ea00 1.OOE-03 1
1.00E-03 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.OOE+00 1 1.00E+00 8.86E-10 1 1.00E+00 0.88 8.76E-01
RCAZDO0515N RCAZD00516N RCCCFPORVC RCHFDPLOCA SWCCIPUMPSR TLMTRANS 86 T10000SW ACB2FIBS17 ACTRAINS AXXVN09728 NOSBO PCF SWCCPUMPSS TRANSX 87 T10000SW ACB2FIBS18 ACTRAINA AXXVN09728 NOSBO PCF SWCCPUMPSS TRANSX 88 TI0000SW AAAATRANSI ACCBD2BTAA CVHFDSUCTN IAAACSA02R IAHFDCSA04 NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCIPUMPSR 89 TI0000SW AAAATRANSI ACCBD521 1A CVHFDSUCTN LA.AACSA02R IAHFDCSA04 NOSSO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR 90 T10000SW ACB2FIBS17 ACTRAINB AXHFDSAFWX FSAZCORRO3 NOS8 PCF SWMMOSWPAS SWMMOSWPCS TRANSX 91 TIOO0OSW ACB2FIBS18 ACTRAINA AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWMMOSWPBS SWMMOSWPDS TRANSX 92 TIOOOOSW ACB2FIBS17 ACTRAINB AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1DR SWCVC04604 SWPMPDINIT SWTMPUMPIA TRANSX 93 TIO000SW ACB2FIBS17 ACTRAINB AXXVN09728 NOSBO PCF SWMM0SWPCS SWTMPUMP1A TRANSX 94 T10000SW AXHFLSAFWA AXHFLSAFWB NOSBO PCF SWCXXSUCTI TRANSX 95 T10000SW AAAATRANSI CVHFDSUCTN CVMM00112B CVMMRXMAKE NOSBO PCF RCAZ00t RCP SEALLOCA SSLO SWCCIPUMPSR 96 TI0000SW AXMMSGASAF AXTMSAFSGB NOSBO PCF SWCCIPUMPSR TRANSX 97 T10000SW NOSBO Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage PORVs FAIL TO CLOSE (CCF)
Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 4160 VAC Bus 11A / Bus 12A Tie Breaker 521BTA-A (BUS1 t1A/1) Fails to Close Operators Fail to Manually Open Suction Line Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failurl Of Service Water Pumps To Run Total Loss of Service Water TAG -Transient Initiating Event Which Eventually Rsults In SI Conditions (Seal LOCA) 4160 VAC Circuit Breaker 5211 1A (BUS1 1A10) Fails To Open on Demand Operators Fail to Manually Open Suction Une Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
Correctin Factor for Operators Failing to align SAFW due to increased stress duoing loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START FAILURES OF SW PUMP C TO START TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Operators Fail to Correctly Align SAFW (Corrected for TIO000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stresw during loss of SWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP B TO START FAILURES OF SW PUMP D TO START TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFWdue to increased stress during loss of SWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG-Service Water Pump PSWIlD Is In Operation Service Water Pump PSW01 D Discharge Check Valve 4604 Fails To Close On Demand TAG - SW PUMP D FAILS AS AN INITIATING EVENT SW Pump A in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failura of AC Train B 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Failure to restore SAFW Pump Train 1 C to service post test/maint Failure to restore SAFW Pump Train 1 D to service post toestmaint TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 112B FAILS TO OPEN ON DEMAND FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR 0 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water Failure of SAFW injection line to S/G A SAFW TRAIN D TO SbG B O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Seroice Water TAG - NO STATION BLACKOUT 0.97 9.67E-01 0.97 9.67E-01 1.79E-04 1.79E-04 0.05 5.00E-02 1.21E-04 1.21E-04 I 1.00E-00 1 1.00Eg00 8.84E-10 1.01 E-06 1 8.85E-03 1 1.00E+00 1.00E-03 1 1.00E-03 1 1.O0E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.O0E+00 1 1.001+00 8.84E-10 1.01E-06 1 8.85E-03 1 1.00E+00 1.00E-03 1 i.00E-03 I 1.00EO+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.00E+00 8.78E-10 1 1.00E+00 3.64E-03 1 3.64E-03 0.02 2.40E-02 0.95 9.50E-01 0.1 1.00E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1-00E+00 1.21E-04 1.21E-04 1 1.00E+00 8.78E-10 1 1.00E+00 3.64E-03 1 3.64E-03 0.02 2.40E-02 0.95 9.50E-01 0.1 1.00E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E-00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 8.34E-10 1.01E-06 1 8.05E-03 1 1.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 3.28E-03 3.28E-03 1 1.001+00 I 1.00E+00 8.34E-10 1.01E-06 1 8.85E-03 1 1.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.78E-01 3.28E-03 3.28E-03 3.28E-03 3.28E-03 1 1.00E+00 1 1.00E+00 8.201-10 1.01E-06 1 8.85E-03 1 1.00E+00 5.19E-03 5.190E-03 1 1.93E+00 1 1.00E+00 0.98 8.76E-01 0.58 5.79E-01 5.84E-04 1 5.84E-04 1 1.00E+00 0.03 3.13E-02 1 1.00E+00 1 1.00E+00 7.96E-10 1.01E-08 I 8.85E-03 1 1.00E+00 1.00E-03 1 1.00E-03 I 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.03 3.130-02 1 1.00E+00 1 1.00E+00 7.88E-10 3.OOE-03 3.00E-03 3.00E-03 3.00E-03 I 1.00E+00 0.88 8.76E-01 1.000-04 1.00-04 1 1.00E+00 1 1.00E+00 7.84E-10 1 1.00E+00 0.02 2.40E-02 0.18 1.83E-01 1.69E-03 1.69E-03 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 7.78E-10 4.97E-04 4.97E-04 0.01 1.48E-02 I 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 I 1.00E+00 7.67E-10 1 1.00E+00
PCF RCAZD0051 SN RCMMO00515 RCRZT0431C SLO SWCCIPUMPSR TLSTRANS 98 T10000SW NOSBO PCF RCAZD00516N RCMM000516 RCRZT00430 SLO SWCCIPUMPSR TLSTRANS 99 TI0000SW NOSBO PCF RCAZD0051 SN RCCCFPORVC RCHFDPLOCA SLO SWCXXSUCTI TLSTRANS 100 TI0000SW NOSBO PCF RCAZD00516N RCCCFPORVC RCHFDPLOCA SLO SWCXXSUCTI TLSTRANS 101 TI000SW MLO PCF RCAZOOS1SN RCAZD00516N RCCCFPORVC RCHFDPLOCA SWCXXSUCTI TLMTRANS 102 T10000SW AAAATRANSI ACCBD2ETAA CVHFDSUCTN IAAACSA02R IAHFDCSA04 NOSBO PCF RCAZ01 RCP SEALLOCA SSLO SWCXXSUCTI 103 TI0000SW AAAATRANSI ACCBO5211A CVHFDSUCTN IAAACSA02R IAHFDCSA04 NOSBO PCF RCAZS01RCP SEALLOCA SSLO SWCXXSUCTI 104 TI0000SW ACB2FIBS18 ACTRAINA AXHFDSAFWX FSAZCORR03 NOSBO PCF SWMMSWPDRT SWTMPUMP1B TRANSX 105 TI0000SW AAAATRANSI CVHFDSUCTN CVMM7T0S/A CVMMRXMAKE NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR 106 TI0000SW ACAAS_505N ACAZDLOSPI ACLOPNOSi2 ACLOPRTALL ACTRAINA ACTRAINB AFAXITDAFW OGIANOTRUN DGI BNOTRUN PCF S8O SWCCIPUMPSR SWTODG 107 TI0OOSW AXCCPSGINB NOSBO PCF SWCCIPUMPSR TRANSX 108 T10000SW ACAA50_50A ACAZOLLOSP1 ACLOPNOSI2 ACLOPRTALL ACTRAINA PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage ELECTRICAL FAILURES PREVENT MOVING MOV-515 PORV PCV-431 C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage ELECTRICAL FAILURES PREVENT MOVING MOV-516 PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage PORVs FAIL TO CLOSE (CCF)
Operators Fail To Close PORV Block Valfe (5159516) To Termlinate LOCA Won 3 Min TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage PORVs FAIL TO CLOSE (CCF)
Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA WIln 3 Min TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - MEDIUM LOCA SEQUENCE PLANT CAPACITY FACTOR Motor-Operated Vale 515 Is Not Closed Due to PORV Leakage Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage PORVs FAIL TO CLOSE (CCF)
Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA WIln 3 Min TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in S1 Conditions (Seal LOCA) 4160 VAC Bus 1A/ Bus 12A Tie Breaker 52/1TA-A (BUS11A/11) Fails to Close Operators Fail to Manually Open Suction Line Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR - 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Inltiatiag Event Which Eventually Results in SI Conditions (Seal LOCA) 4160 VAC Circuit Breaker 52/t1A (BUS1 1A/10) Fails To Open on Demand Operators Fail to Manually Open Sucdon Line Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP D TO RUN SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Whtich Eventually Results in SI Conditions (Seal LOCA)
Operators Fail to Manually Open Suction Line Upon Loss of IA VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
Failure to Restore Offsfe PowerWdhin 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Ant Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG lA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water Common cause failure of check avles 9705A and 9705B to open TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG -TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss ofJl Off-See Power Following Reactor Trp TAG - Failure of AC Train A 0.88 8.76E-01 0.97 9.87E-01 1.5OE-03 1.50E-03 5.00E-03 I 5.O0E-03 I 1.OOE+00 1.21E-04 1.21E-04 I 1.00E+00 1 1.00E-00 7.67E-10 1 1.00E800 0.88 8.76E-01 0.97 9.67E-01 1.50E-03 1.50E-03 5.00E-03 I
5.00E-03 I 1.OOE+00 1.21E-04 1.21E-04 I 1.00E+00 1 1.00E+00 7.58E-10 I 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 1-79E-04 1.79E-04 0.05 5.00E-02 I 1.00E+00 1.0OE-04 1.00E-04 1 1.00E+00 1 1.00E+00 7.58E-10 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 1.79E-04 1.79E-04 0.05 5.00E-02 1 1.00E+00 1.00E-04 1.00E-04 1 1.006E00 1 1.006E00 7.34E-10 1 I.00+E00 0.88 8.76E-01 0.97 9.67E-01 0.97 9.67E-01 1.79E-04 1.79E-04 0.05 5.00E-02 1.00E-04 1.00E-04 1 1.00E+00 1
.00OE+00 7.27E-10 1 1.00E+00 3.64E-03 1 3.64E-03 0.02 2.40E-02 0.95 9.50E-01 0.1 1.00E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 7.27E-10 1 1.00E+00 3.64E-03 1 3.64E-03 0.02 2.40E-02 0.95 9.50E-01 0.1 1.00E-01 1 1.006E00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 7.22E-10 1.01E-06 I 8.85E-03 1 1.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0-88 8786E-01 2.05E-04 2.05E-04 0.05 4.55E-02 1 1.00E+00 1 1.00E+00 7.16E-10 1 1.00E+00 0.02 2.40E-02 0.17 1.67E-01 1.69E-03 1.69E-03 1 1.00E+00 0.88 8-76E-01 1 1.00E+00 1 1.00E+00 1 1.00OE00 1.21E-04 1.21E-04 1 1.00E+00 7.15E-10 0.02 1.70E-02 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00OE+00 I 1.0DE+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 6.71E-10 6.35E-06 8.35E-06 I 1.0OE+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.006+00 1 1.00E+00 8.59E-10 0.83 8.25E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.101-03 1 1.00E+00
ACTRAINB AFTMOTDAFW DOGIANOTRUN DGI BNOTRUN PCF S0O SWCCIPUMPSR SWTODG 109 T10000SW AAAATRANBI CVHFDSUCTN CVMM00112B CVMMRXMAKE NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCXXSUC-n 110 T10000SW AXMMSGASAF AXTMSAFSGB NOSBO PCF SWCXXSUCTI TRANSX 111 T10000SW NOSBO PCF RCAZDO0515N RCMM000515 RCRZT0431C SLO SWCXXSUCTI TLSTRANS 112 T10000SW NOSBO PCF RCAZD00516N RCMM000516 RCRZT0O430 SLO SWCXXSUCTI TLSTRANS 113 T10000SW ACAA0_100X ACAZDLOSP1 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAXITDAFW`
DGIANOTRUN DG1BNOTRUN PCF SBO SWCCIPUMPSR SWrODG 114 T10000SW ACAA100_OX ACAZDLOSP1 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB AFAX1TDAFW DGiANOTRUN DGIBNOTRUN PCF SBO SWCCIPUMPSR SWTODG ACHFDRCOFF 115 T10000SW ACB2FIBS18 ACTRAINA AXMMSAFWPC AXMMSAFWPD NOSBO PCF SWMMOSWPDS SWTMPUMP1B TRANSX 116 T10000SW AAAATRANSI CVHFDSUCTN CVMM7005/A CVMMRXMAKE NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWCXXSUCTI 117 T10000SW ACAA5050N ACAZDLOSP1 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAXITDAFW DGIANOTRUN DG1BNOTRUN PCF Sao SWCXXSUCTI SWTODG 118 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASCREEN TAG - Failure of AC Train B TDAFW Pump Train out-of-service for maintenance FLAG - DOG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -0G 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 1128 FAILS TO OPEN ON DEMAND FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Failure of SAFW injection line to S/G A SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage ELECTRICAL FAILURES PREVENT MOVING MOV-515 PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage ELECTRICAL FAILURES PREVENT MOVING MOV-516 PORV PCV-430 Falls To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 701 SUPPLYING BUSES 12A AND 12B)
Failure to Restore Oflsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Top TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B 01 NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Sermce Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 767 Foliowing Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Failure to recover second offsite power circuit after failure of first Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Failure of SAFW Pump 1C train Failure of SAFW Pump ID Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP D TO START SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Wthich Eventually Results in SI Conditions (Seal LOCA)
Operators Fail to Manually Open Suction Une Upon Loss of IA VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED FAILURE OF REACTOR MAKEUP WATER TO THE BLENDER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR o 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 787 TO BUS 12B)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stras during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 1 1.00E+00 0.02 1.90E-02 1 9.97E-01 1 9.97E-01 0.88 8E76E-01 1 1.00E+00 1.21E-04 1.21E-04 I 1.0OE+00 1 1.00E+00 6.50E-10 I 1.00E+00 0.02 2.40E-02 0.18 1.83E-01 1.69E-03 1.69E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E.00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 6.45E-10 4.97E-04 4.97E-04 0.01 1.48E-02 1 1.00E+000 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 6.36E810 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 1.50E-03 1.50E-03 5.00E-03 1 S0OE-03 I 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 8.36E-10 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 1.50E-03 1.50E-03 5.00E-03 1 5.00E-03 1 1.00E+000 1.00E-04 1.000E04 1 1.00E+00 I 1.00E+00 8.31E-10 0.02 1.50E-02 0.38 3.81 E-01 0.5 0.00E-01 2.10E-03 2.10E-03 1 1.00E+00 I 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.21E-04 1-21E-04 1 1 00E+00 1 1.00E+00 6.11E-10 0.14 1.44E-01 0.38 3.81E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.000+00 1 1.00E+00 1 1.000000 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0.1 1.00E-01 I 1.00E+00 6.07E-10 1.01 E-06 1 8-85E-03 1 1.00E+00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.00E+00 1 100E+00 5.93E-10 1 1.00E+00 0.02 2.40E-02 0.17 1.87E-01 1.69E-03 1.69E-03 1 1.COE+00 0.88 8.76E-01 I 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 5.92E-10 0.02 1.70E-02 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00-E04 1 1.00E+00 1 1.00E+00 5.89E-10 5.19E-03 5.19E-03 I 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.1 1.00E-01
SWTSFFSWAI SWTSFFSWBI SWTSFFSWCI TRANSX 119 T10000SW AXHFDSAFWX FSAZCORR03 NOSBO PCF SWAASCREEN SWTSFFSWAI SWTSFFSWBI 0WTSFFSWDI TRANSX 120 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASCREEN SWTSFFSWAI SWTSFFSWCI SWTSFFSWDI TRANSX 121 TI7OOOSW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASCREEN SWTSFFSWBI SWTSFFSWCI SWTSFFSWDI TRANSX 122 T10000SW ACB2FIBS17 ACTRAINB AXHFDSAFWX FSAZCORR03 NOSBO PCF SWMMSWPART SWTMPUMPIC TRANSX 123 T10000SW AXCCPSGINB NOSBO PCF
- WCXXSUCTI TRANSX 124 T10000SW ACAA50_50A ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFTMOTDAFW DGIANOTRUN DG01BNOTRUN PCF SBO SWCXXSUCTI SWTODG 125 T10000SW ACAAOJ100X ACAZDLOSPI ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINS AFAXITDAFW DGIANOTRUN DGIBNOTRUN PCF SBO SWCXXSUCTI SW-TODG 126 T10000SW ACAA1 DOOX ACAZDLOSPI ACLOPNOS12 ACLOPRT767 ACTRAINA ACTRAINS AFAX1TDAFW DGIANOTRUN DG1ENOTRUN PCF SBO SWCXXSUCTI SWTODG ACHFDRCOFF 127 T10000SW ACB2FIBS17 ACTRAINS AXHFDSAFWJX FSAZCORRO3 NOSBO PCF SWMMSWPCRT SWTMPUMP1A TRANSX 128 T10000SW FSXVK8549 NOSBO PCF SWCCIPUMPSR TRANSX 129 T10000SW ACB2FI6S17 ACTRAIN8 AXMMSAFWPC AXMMSAFWPD PLUGGING OF TRAVELLING SCREEN FWSOIA PLUGGING OF TRAVELLING SCREEN FWSOI B PLUGGING OF TRAVELLING SCREEN FWSOIC TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAPW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SWlo TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG. CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY PLUGGING OF TRAVELLING SCREEN FWSO1A PLUGGING OF TRAVELLING SCREEN FWS0B PLUGGING OF TRAVELLING SCREEN FWS01D TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY PLUGGING OF TRAVELLING SCREEN FWS01A PLUGGING OF TRAVELLING SCREEN FWSO1C PLUGGING OF TRAVELLING SCREEN FWS01D TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY PLUGGING OF TRAVELLING SCREEN FWOS1B PLUGGING OF TRAVELLING SCREEN FWS01C PLUGGING OF TRAVELLING SCREEN FWSO1D TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress durng loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SERVICE WATER PUMP A TO RUN SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Common cause failure of dieck vnales 9705A and 9705B to open TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Wethin 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Top TAG - Failure of AC Train A TAG - Failure of AC Train B TDAFW Pump Train out-of-service for maintenance FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to 10 (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AtI Off-SOle Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TOAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO S? CONDITION FOR LOOP Less of OfGsle Circuit 767 Following ReactorTrip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfulty FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Failure to recover second offsie power circuit after failure of first Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
Corection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP C TO RUN SW Pump A in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water MANUAL VALVE 8549 TRANSFERS CLOSED TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water Local Faulv on 480 VAC Bus 17 TAG - Failore of AC Train B Failure of SAFW Pump IC train Failure of SAFW Pump 1D Train 1.00E-06 1 8.76E-03 1.006-06 1 8.76E-03 1.00E-06 1 8.76E-03 I 1.00E+00 1 1.00E+00 5.89E.10 5.19E-03 5.198-03 1 1.93E+00 1 1.006+00 0.88 8.76E-01 0.1 1.00E-01 1.00E-06 1 8.786-03 1.00E-06 1 8.76E-03 1.00E-06 I 8.76E-03 1 1.00E+00 1 1.006E00 5.89E-10 5.1GE-03 5.19E-03 I 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.1 1.00E-01 1.00E-06 1 8.76E-03 1.00E-06 1 8.76E-03 1.00E-06 1 8.786E-03 1 1.00E+00 I 1.00E+00 5.89E-10 5.19E-03 5.19E-03 1 1.93E+00 1 1.006E00 0.88 8.76E-01 0.1 1.00E-01 1.00E-06 1 8.76E-03 1.00E-06 1 8.76E-03 1.00E-06 1 8.76E-03 1 1.00E+00 I 1.00E+00 5.65E-10 1.016E-0*
1 8.85E-03 1 1.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 2.05E-04 2.05E-04 0.04 3.56E-02 I 1.00E+00 I 1.00E+00 5.56E-10 6.35E-06 8.35E-00 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 5.486E-10 0.83 8.25E-01 0.38 3.816-01 0.5 5.00E-01 2.1OE-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.02 1.90E-02 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 I 1.00E+00 1.006-04 1.00E-04 1 1.00E+00 1 1.00E+00 5.23E-10 0.02 1.50E-02 0.38 3-81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 1.00oE+0 1 9.97E-01 1 9.97E-01 0.88 8.768-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 5.06E-10 0.14 1.44E-01 0.38 3.81E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0.1 1.00E-01 1 1.00E+00 4.96E-10 1.01E-06 1 8.85E-03 1 1.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 2.05E-04 2.05E-04 0.03 3.13E-02 I 1.00E600 1 1.00E+00 4.92E-10 1.94i-07 24 4.66E-08 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.006+00 4.75E-10 1.01E-06 1 8.85E-03 1 1.00E+00 0.02 2.29E-02 0.02 2.29E-02
___a a
a NOSBO PCF SWMMOSWPAS SWTMPUMPIC TRANSX 130 TI0000SW ACB2FIBSI7 ACTRAINB AXMMSAFWPC AXMMSAFWPD NOSBO PCF SWCCPUMPSS TRANSX 131 T10000SW ACB2FIBS18 ACTRAINA AXMMSAFWPC AXMMSAFWPD NOSBO PCF SWCCPUMPSS TRANSX 132 T10000SW ACAA50_50A ACLOPNOSI2 ACLOPRT751 ACTRAINB DGIBNOTRUN NOSBO PCF RCAZD00515N RCRZT0431C SLO SWCCIPUMPSR SWrODG TLSTRANS 133 T10000SW ACAA*0_50A ACLOPNOSI2 ACLOPRT767 ACTRAINA DGlANOTRUN NOSBO PCF RCAZDO0516N RCRZT00430 SLO SWCCIPUMPSR SWTODG TLSTRANS 134 T10000SW ACAA50-50A ACLOPNOSt2 ACLOPRTALL ACTRAINA DGIANOTRUN NOSBO PCF RCAZD00516N RCRZT00430 SLO SWCCIPUMPSR SWTODG TLSTRANS 135 T10000SW ACAAS_50CA ACLOPNOSI2 ACLOPRTALL ACTRAINB DGIBNOTRUN NOSBO PCF RCAZD00515N RCRZT0431C SLO SWCCIPUMPSR SWTODG TLSTRANS 136 T10000SW AAAATRANSI ACAA100_OX ACLOPNOSI2 ACLOPRT767 ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DGIBNOTRUN NOSSO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 137 T10000SW AAAATRANSI ACAA1000iX ACLOPNOSI2 ACLOPRTALL ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DG1BNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 138 T10000SW TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Servce Water Local Fauft on 480 VAC Bus 17 TAG - Failure of AC Train 8 Failure of SAFW Pump 1C train Failure of SAFW Pump 1D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Failure of SAFW Pump 1C train Failure of SAFW Pump 1D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO S0 CONDITION FOR LOOP Loss of Offshe Circuit 751 Following Reactor Trip TAG - Failure of AC Train B FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circus 767 Following Reactor Trip TAG - Failure of AC Train A FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-SOte Power Following Reactor Trip TAG - Failure of AC Train A FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Sevice Water Pumps To Run TAG - SW Lost to DG fcooling)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water FLAG - OFFSITE POWER MODE 80/50 ALT (CKT 751 TO BUS 12B. CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train B FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES I1 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 510 Is Not Closed Due to PORV Leakage PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (ceoling)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Coeditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 123 AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offshe Circuit 767 Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Treoslent Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO S0 CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (ceoling)
Total Loss of Service Water 1 1.00+500 0.88 8.76E-01 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 4.64E-10 1.01E-06 1 8.85E-03 1 1.00E+00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.00E+00 4.641-10 1.01E-06 1 8.85E-03 1 1.00E+00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.000+00 4.46E-10 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 I 1.00E+00 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 5.00E-03 1 5.00E-03 I 1.00E+00 1.21E-04 1.21E-04 I 1.00E+00 1 1.00E+00 I 1.00E+00 4.46E-10 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 5.00E-03 1 5.00E-03 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 4.42E-10 0.83 8.25E-01 0.5 5.0OE-01 2.10E-03 2.10E-03 1 1.00E+00 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 5.00E-03 1 5.00E-03 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 4.42E-10 0.83 8.25E-01 0.5 5.00E-01 2.10-E03 2.10E-03 1 1.00E+00 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.87 9867E-01 5.0OE-03 1 5.00E-03 1 1.00E+00 1.21E-04 1.21E-04 1 1.001+00 1 1.00E+00 1 1.00E+00 4.40E-10 1 1.00E+00 0.14 1.44E-01 0.5 5.001-01 2.12E-03 2.12E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.971-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 4.36E-10 1 1.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1
9.97E-01 1 1.001+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 I 1.00E+00 1.21E-04 1.21E-04 1 1 00E+00 I 1.00E+00 4.17E-10
ACB2FIBS17 ACTRAINB AXMMSAFWPC AXMMSAFWPO NOSBO PCF SWMMOSWPCS SWTMPUMP1A TRANSX 139 TIOCOSOW AAAATRANSI CVHFDSUCTN CVMM00110B CVMM001 12B NOSBO PCF RCAZ00I RCP SEALLOCA SSLO SWCCIPUMPSR 140 TI0008SW FSXVK8549 NOSBO PCF SWCXXSUCTI TRANSX 141 T10000SW ACAA50_50A ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFMMOTDAFW DGIANOTRUN DG1 BNOTRUN PCF SBO SWCCIPUMPSR SWTODG 142 TIO0OOSW AAAATRANSI ACAA50_50A ACLOPNOSI2 ACLOPRT767 ACTRAINA CVHFDSUCTN CVMM001 12B DGlANOTRUN IBAABUSBMX NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 143 TIOCOSW AAAATRANSI ACAA50_50A ACLOPNOSI2 ACLOPRTALL ACTRAINA CVHFDSUCTN CVMM001 12B DGIANOTRUN IBAABUSBMX NOSBO PCF RCAZOOIRCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 144 TIOOOOSW AXMMSAFWPD AXTMSAFSGA AXXVK9702D NOSBO PCF SWCCIPUMPSR TRANSX 145 T10000SW ACAAS0_50A ACAZDLOSPI ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAX1TDAFW DGIANOTRUN DGlBNOTRUN PCF SBO SWMMOSWPDS SWTMPUMPI B SWTODG 14e TI00OOSW AAAATRANSI CVHFDSUCTN CVMM001108 CVMM70051A NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR 147 TIOOOOSW ACAA50_50A ACLOPNOSI2 ACLOPRT751 ACTRAINS Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Failure of SAFW Pump IC train Failure of SAFW Pump 1D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Evenlually Results in SI Conditions (Seal LOCA)
Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 1108 FAILS TO OPEN OR TRANSFERS CLOSED AOV 112B FAILS TO OPEN ON DEMAND TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR u 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water MANUAL VALVE 8549 TRANSFERS CLOSED TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AD Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Failure of TDAFW pump train components FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in 0I Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKlT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 112B FAILS TO OPEN ON DEMAND FLAG - 00 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - InstIrment Bus B on Normal Supply TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to 0G (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKOT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Operators Fail to Manually Open Suction bne Upon Loss of IA AOV 112B FAILS TO OPEN ON DEMAND FLAG - D0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - Instrument Bus B on Normal Supply TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR u 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooeing)
Total Loss of Service Water Failure of SAFW Pump 1 D Train SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM Manual valve 9702D transfers closed TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG. TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Within 1 Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG. DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG-DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG. STATION BLACKOUT SEQUENCE FAILURES OF SW PUMP D TO START SW Pump B in maintenance TAG - SW Lost to 0G (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LOCA)
Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 1108 FAILS TO OPEN OR TRANSFERS CLOSED VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED TAG -NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Tnp TAG - Failure of AC Train B 1.01E-06 1 8.85E-03 1 1.00E800 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 1 1.00E+00 4.10E-10 1 1.00E+00 0.02 2.40E-02 8.83E-04 8.83E-04 0.18 1.83E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E800 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 4.08E-10 1.94E-07 24 4.86E-06 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 4.06E810 0.83 8.25E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.01 1.17E-02 1 9.97E-01 1 9.97E-01 0.88 8.78E-01 1 1.00E+00 1.218E-4 1.21E-04 1 1.00E+00 1 1.00E+00 4.04E-10 1 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.128-03 2.128-03 1 1.00E+00 0.02 2.40E-02 0.18 1.83E-01 1 9.97E-01 1 9.99E-01 1 1.00E+00 0.88 8.76E-01 1 1.00+>00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 4.01E-10 1 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 0.02 2-40E-02 0.18 1.83E-01 1 9.978-01 1 9.99E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E>00 1 1.00E+00 1 1.00E800 1.21E-04 1.21E-04 1 1.001+00 I 1.00E+00 3.80E-10 0.02 2.29E-02 0.02 1.67E-02 1.07E-07 87624 9.38E-03 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E÷00 1 1.0OE+00 3.80E-10 0.83 8.28E-01 0.38 3.81E-01 1.01E-06 1 8.85E-03 0.5 5.0OE-01 2.10E-03 2.10E-03 1 108OE+00 I 1.00E+00 I 11.00EO00 I 9.97E-01 I 9.97E.-01 0.88 8.76E.01 1 11.00E+00 3.28E-03 3.28E-03 0.05 4.55E-02 I 11.00E+00 I 11.00E÷00 3.74E-10 1 1.00E+00 0.02 2.40E-02 8.83E-04 8.83E-04 0.17 1.67E-01 I 1.00E+00 0.88 8.76E-01 1 1.ODE+D0 I 1.00E+00 I1 t.00E÷00 1.21 E-04 1.21 E-04 I 1.00E+00 3.69E.10 0.83 8.25E-01 0.5 5.0DE-01 2.12E-03 2.12E-03 I 1.00E÷O0
DGIBNOTRUN NOSBO PCF RCAZDO0515N RCRZT0431C SLO SWCXXSUCTI SWTODG TLSTRANS 148 TI000OSW ACAASO 50A ACLOPNOSI2 ACLOPRT767 ACTRAINA DGlANOTRUN NOSBO PCF RCAZD00516N RCRZT00430 SLO SWCXXSUCTI SWTODG TLSTRANS 149 TI0000SW AAAATRANSI ACAA5SI50A ACLOPNOSI2 ACLOPRT767 ACTRAINA CVHFDSUCTN CVMM7050/A DGIANOTRUN IBAABUSBMX NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 150 TI0000SW ACAA100_OX ACLOPNOSI2 ACLOPRT787 ACTRAINA AXMMSAFWPD DG1ANOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 151 TIS00OSW ACAA 100 OX ACLOPNOSI2 ACLOPRT767 ACTRAINB AXMMSAFWPC DGtBNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 152 TI0000SW ACAA505_0A ACLOPNOSI2 ACLOPRTALL ACTRAINA DGIANOTRUN NOSBO PCF RCAZD00516N RCRZTO0430 SLO SWCXXSUCTI SWTODG TLSTRANS 153 TISOOSW ACAASO_50A ACLOPNOSI2 ACLOPRTALL ACTRAINB DG1BNOTRUN NOSBO PCF RCAZD00515N RCRZT0431C SLO SWCXXSUCTI SWTODG TLSTRANS 154 TIOOOOSW AAAATRANSI ACAA50.SOA ACLOPNOSI2 ACLOPRTALL ACTRAINA CVHFDSUCTN CVMM7005/A DGIANOTRUN IBAABUSBMX NOSO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 155 TI0000SW ACAAI 00 OX ACLOPNOSI2 ACLOPRTALL ACTRAINA FLAG - OG 8 IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG -TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 757 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 51 Is Not Closed Due To PORV Leakage PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Resufts in St Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Operators Fa/ to Manually Open Suction Une Upon Loss of IA VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED FLAG - DG 0A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - Instrument Bus B on Normal Supply TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Failure of SAFW Pump 1 D Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Otfste Circuit 787 Following Reactor Trip TAG - Failure of AC Train B Failure of SAFW Pump 1C train FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 1ZA)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following ReactorTep TAG - Failure of AC Train A FLAG - DG A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is NOt Closed Due To PORV Leakage PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to 00 (cooling)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128. CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Sfte Power Following Reactor Top TAG - Fauore of AC Train B FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Resuets In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Operators Fail to Manually Open Suction Une Upon Loss of IA VALVES IN INSTRUMENT AIR LINE TO SOV 142565 AND AOV 112C FAIL CLOSED FLAG - 0* 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - Instrument Bus B on Normal Supply TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water FLAG -OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A 1
9.97E-01 1 1.00E-00 0.88 8.76E-01 0.97 9.671-01 5.OE-03 1 5.OOE-03 1 1.00E+00 1.00E-04 1.00E-04 1 1.O0E+00 1 1.00E+00 I1.00E+00 3.69E-10 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 9.97E-01 1 1.00E÷00 0.88 8.7E-01 0.97 9.67E-01 5.00E-03 1 5.00E-03 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 1 1.O0E÷00 1 1.OE+00 3.69E-10 1 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00Eu00 0.02 2.40E-02 0.17 1.67E-01 1 9.97E-01 1 8.99E-01 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00Eo00 I 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 3.695-10 0.14 1-44E-Ol 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E+00 I 1.00E+00 1 1.00E+00 3.88E-10 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E+00 1 1.OE+00 1 1.00E+00 3.68E-10 0.83 8.25E-01 0-5 6.00E-01 2.10E-03 2.10E-03 1 1.00E+00 I 9.87E-01 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 5.00E-03 1 5.00E-03 1 1.0012+00 1.00E-04 1.00E-04 1 1.00E000 1 1.00E+00 1 1.005+00 3.60E510 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.1OE-03 1 1.00E+00 1 0.87E-01 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 5.005-03 1 5.00E-03 1 1 00Eo00 1.00E-04 1.00E-04 1 1.00E+00 I 1.00E+00 1 1.00E+00 3.56E-10 1 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 0.02 2.40E-02 0.17 1.675-01 1 9.97E-01 1 9.99E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 3.85E-10 0.14 1.44E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00
AXMMSAFWPD DGIANOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 156 T10000SW ACAA100OX ACLOPNOSI2 ACLOPRTALL ACTRAINB AXMMSAFWPC DGO1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 157 T10000SW AAAATRANSI ACAA100_OX ACLOPNOSI2 ACLOPRT767 ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DGI BNOTRUN NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 158 T10000SW AAAATRANSI ACAA100_OX ACLOPNOSI2 ACLOPRTALL ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DGIBNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 159 T10000SW AAAATRANSI CVHFDSUCTN CVMM00110B CVMM00112B NOSED PCF RCAZOOIRCP SEALLOCA SSLO SWC)X(SUCTI 160 T10000SW ACAA50-50A ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFMMOTDAFW DG1ANOTRUN DG1BNOTRUN PCF SBO SWCXXSUCTI SWTODG 161 710000SW AXMMSAFWPC AXTMSAFSGB AXXVK9702D NOSBO PCF SWCCIPUMPSR TRANSX 162 T10000SW AAAATRANBI ACAA50_50A ACLOPNOSI2 ACLOPRT767 ACTRAINA CVHFDOSUCTN CVMM00112B DG1ANOTRUN IBAABUSBMX NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 163 T10000SW AAAATRANSI ACAA50O_0A ACLOPNOSI2 ACLOPRTALL ACTRAINA CVHFDSUCTN CVMM00112B DGIANOTRUN IBAABUSBMX NOSBO Failure of SAFW Pump ID Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All OffnS-te Power Following Reactor Trip TAG - Failure of AC Train B Failure of SAFW Pump IC train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG -TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Whi/c Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor T
rip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Tnp TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR a 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 110B FAILS TO OPEN OR TRANSFERS CLOSED AOV 112B FAILS TO OPEN ON DEMAND TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR a 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Within I Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Tfip TAG - Failure of AC Train A TAG - Failure of AC Train B Failure of TDAFW pump train components FLAG-DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Tatal Loss of Service Water Failure of SAFW Pump IC train SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M Manual valve 97020 transfers caosed TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Operators Fail to Manually Open Suction Line Upon Lass of IA AOV 1128 FAILS TO OPEN ON DEMAND FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - Instrument Bus B on Nonnal Supply TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR
- 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 1128 FAILS TO OPEN ON DEMAND FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - Instrument Bus B on Normal Supply TAG - NO STATION BLACKOUT 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 0.7BE-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 I 1.00E+00 3.65E-10 0.14 1.44E-01 0.5 5.00E-01 2.1OE-03 2.10E-03 1 1.001+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 I.00E+00 1 1.00E+00 1 1.001+00 3.64E-10 1 1.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 I 1.00E+00 1.00E-04 1.00E-04 1 1.00E600 I 1.00E+00 3.61E-10 1 1.00E+00 0.14 1.44E-01 0.5 5.0OE-01 2.10E-03 2.10E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E600 1 1.00E+00 1 1.00aE00 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 3.40E-10 I 1.00E+00 0.02 2.40E-02 8-83E-04 8.83E-04 0.18 1.83E-01 1 1.00E+00 0.88 8.766-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.006-04 1.00E.04 1 1.00E+00 3.36E-10 0.83 8.25E-01 0.38 3.81E-01 0.5 5.00En01 2.10E-03 2.10E-03 1 1.00E+00 1 1.0OE+00 0.01 1.17E-02 I
9.97E-01 1 9.97E-01 0.88 8.76E-01 I 1,00E+00 1.00E-04 1.00E-04 1 1.00E+00 I 1.00E+00 3.36E-10 0.02 2.29E-02 0.01 1.48E-02 1.07E-07 87624 9.38E-03 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.006E00 3.35E-10 1 1.00E+00 0.03 0.25E601 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 0.02 2.40E-02 0.18 1.83E-01 1 9.97E-01 1 9.99E-01 1 1.00E+00 0.88 8.76EW01 1 1.00E+00 1 1.00E+00 1 1.00+O00 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 3.32E-10 1 1.001+00 0.83
&25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 0.02 2.40E-02 0.18 1.83E-01 I
9.97E-01 1 9.991-01 1 1.00E+00
PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 164 TIOOOESW AXMMSAFWPD AXTMSAFSGA AXXVKg702D NOSBO PCF SWCXXSUCTI TRANSX 165 TIOOOOSW AAAATRANSI CVHFDSUCTN CVMM00110B CVMM7005/A NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWCXXSUCTI 166 TIOOOOSW AAAATRANSI ACAA50ESEA ACLOPNOSI2 ACLOPRT767 ACTRAINA CVHFDSUCTN CVMM700S/A DGIANOTRUN IBAABUSBMX NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 167 TI0000SW ACAA100_OX ACLOPNOSI2 ACLOPRT767 ACTRAINA AXMMSAFWPD DGIANOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 168 TIEOOOSW ACAA100_OX ACLOPNOSI2 ACLOPRT767 ACTRAINB AXMMSAFWPC DGIBNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 169 TI000OSW AAAATRANSI ACAASOE50A ACLOPNOSI2 ACLOPRTALL ACTRAINA CVHFDSUCTN CVMM7005/A DGIANOTRUN IBAABUSBMX NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 170 TIOOOOSW ACAA100_OX ACLOPNOSI2 ACLOPRTALL ACTRAINA AXMMSAFWPD DGIANOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 171 TI00SOSW ACAAI00_0X ACLOPNOSI2 ACLOPRTALL ACTRAINB AXMMSAFWPC DGIBNOTRUN NOSBO PCF SWCXXSUCT1 SWTODG TRANSX 172 TI00OOSW ACAAS E50A ACAZDLOSPI ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Failure of SAFW Pump 1D Train SAFW TRAIN C TO S/G A 0.0.S. DUE TO T/M Manuat valve 9702D transfers cdosed TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Operators Fail to Manually Open Suction Line Upon Loss of IA AOV 110B FAILS TO OPEN OR TRANSFERS CLOSED VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CK0T 767 TO BUS 12A)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Operators Fail to Manually Open Suction Une Upon Loss of IA VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED FLAG-DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - Instrument Bus B on Normal Supply TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offste Circui 767 Following Reactor Trip TAG - Failure of AC Train A Failure of SAFW Pump 1D Train FLAG - DG lA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsoe Circuit 767 Following Reactor Trip TAG - Failure of AC Train B Failure of SAFW Pump 1C train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Operators Fail to Manually Open Suction Line Upon Loss of IA VALVES IN INSTRUMENT AIR LINE TO SOV 14206S AND AOV 112C FAIL CLOSED FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - Instrument Bus B on Normal Supply TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR a I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Failure of SAFW Pump 1D Train FLAG - DOG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Setvice Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of A/ Off-Site Power Following Reactor Trip TAG - Failure of AC Train B Failure of SAFW Pump 1C train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Sorvco Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
Failure to Restore Offsite Power WOihin 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Sie Power Following Reactor Trip TAG - Failure of AC Train A 0.88 8.76E-01 I 1.00E+00 1 1.OE÷00 I 1.00E+00 1.00E-04 1.00E-04 1 1.80E+00 1 1.00E+00 3.15E-10 0.02 2.29E-02 0.02 1 676-02 I.07E-07 87624 9.38E-03 1 1.08E>00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 3.10E-10 1 1.00E+00 0.02 2.40E-02 8.83E-04 8.83E-04 0.17 1.67E-01 1 1.00E+00 0.88 8.76E-E1 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.08E-04 1.00E-04 I 1.00E÷00 3.06E-10 1 1.00E+00 0.83 8.25E-01 0.5 6.00E-01 2.12E-03 2.12E-03 1 1.00E+00 0.02 2.40E-02 0.17 1.67E-01 1 9.97E-01 1 9.99E-01 1 1.00E-00 0.88 8.76E-01 1 1.00E+00 1 1.00E-00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 3.06E-10 0.14 1-44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.08E+00 0.02 2.29E-02 1 9.97E-01 1 1.0E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.006E00 1 1.00E+00 3.O5E-10 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 I.00E+00 1 1.00E+00 1 1.00E+00 3.03E-10 1 1.S0E+00 0.83 8.25E-01 0.5 5.0SE-01 2.10E-03 2.10E-03 1 1.00E+00 0.02 2.40E-02 0.17 1.67E-01 1 9.97E-01 1 9.99E-01 1 1.00E+00 0.88 8.76E-01 1 1_00>+00 I 1.0OE+DO I 1.00E+00 1.00E-04 1.08E-04 1 1.00E600 1 1.80E+00 3.03E-10 0.14 1.44E-01 0.5 5.OOE-01 2.10E-03 2.10E-03 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 I 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00+E00 I 1.00E÷00 1 1.00E600 3.02E-10 0.14 1.80E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 0.02 2.29E-02 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 I 1.00E+00 I 1.00E+00 I 11.00E+00 2.97E-10 0.83 8.25E-01 0.38 3.81E-01 1.01E-06 I 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 I 1.00E÷00
ACTRAINB TAG - Failure ofAC Train B AFAXITOAFW TAG - TDAFW Pump operates successfully DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PCF PLANT CAPACITY FACTOR SBE TAG - STATION BLACKOUT SEQUENCE SWMMOSWPAS FAILURES OF SW PUMP A TO START SWTMPUMP1C SW Pump C in maintenance SWTODG TAG - SW Lost to DG (cooling) 173 TIOEOOSW Total Loss of Service Water ACAAS0_5OA FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACAZDLOSPI Failure to Restore Offshte Power Within 1 Hour ACB2FIBS17 Local Fault on 480 VAC Bus 17 ACLOPNOSI2 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B AFAX1TDAFW TAG - TDAFW Pump operates successfully DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PCF PLANT CAPACITY FACTOR SBE TAG - STATION BLACKOUT SEQUENCE SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWTODG TAG - SW Lost to DG (cooling) 174 TISOOSW Total Loss of Service Water ACAASO,50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACAZDLOSPI Failure to Restore Offsile Power Within 1 Hour ACB2FIBS18 Local Fault on 480 VAC Bus 18 ACLOPNOS12 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B AFAXITDAFW TAG - TDAFW Pump operates successfully DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PCF PLANT CAPACITY FACTOR SEO TAG - STATION BLACKOUT SEQUENCE SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWTODG TAG - SW Lost to DG (cooling) 175 TIS00OSW Total Loss of Service Water ACB2FIBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A AXTMSAFSGA SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M AXTMSAFSGB SAFW TRAIN D TO S/G B O.O.S. DUE TO T/M NOSBE TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMPIB SW Pump B in maintenance TRANSX TAG - TRANSIENT EVENT 176 TIEOOOSW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for Tl0OOOSW and Some Fire Events For Stress)
FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBE TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWP1CNR FLAG - Service Water Pump PSW0t C Is Not In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1C SW Pump C In maintenance TRANSX TAG - TRANSIENT EVENT 177 T]0OOOSW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corected for TI0000SW and Some Fire Events For Stress)
FSAZCORRS3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSWS1 B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance TRANSX TAG - TRANSIENT EVENT 178 TISOOOSW Total Loss of Service Water ACB2FIBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A NOSED TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZD0051 SN Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage RCHFDPLOCA Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min RCRZT0431C PORV PCV-431C Fails To Reseat After Steam Relief SLO TAG - SMALL LOCA SEQUENCE SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1B SW Pump B in maintenance TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 179 TIS00OSW Total Less of Service Water ACB2FIBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR RCAZD00516N Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage RCHFDPLOCA Operators Fail To Close PORV Block Value (5151516) To Terminate LOCA W/In 3 Min RCRZT00430 PORV PCV-430 Fails To Reseat After Steam Relief SLO TAG - SMALL LOCA SEQUENCE SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1B SW Pump B in maintenance TLSTRANS TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES 180 TIOOSSSW Total Loss of Service Water AXMMSAFWPC Failure of SAFW Pump IC train AXTMSAFSGB SAFW TRAIN D TO S/G B O-O.S. DUE TO TIM AXXVK9702D Manual valve 97020 transfers csosed NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TRANSX TAG - TRANSIENT EVENT 181 T0000SW Total Loss of Service Water ACAASO50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKlT 751 TO BUS 12B. CKT 767 TO BUS 12A)
ACLOPNOS12 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRT751 Loss of Offsile Circuit 751 Following Reactor Tdp ACTRAINB TAG - Failure of AC Train B AXHFLSAFWA Failure to restore SAFW Pump Train IC to service post teeslrnaint DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR 1 1,OOEo00 1 1.00E-00 I 9.97E-01 I 9.97E-01 0.88 8.76E-E1 1 1 -OE+00 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 I 1.0E÷00 2.90E-10 0.83 8.25E-01 0.38 3.81E-01 1.01E-06 I
8.85E-03 0.5 S.OOE-01 2.10E-03 2.10E-03 1 1.0.E+00 1 1.001E+00 1 1.00EO00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.OOE+00 1.14E-04 1.14E-04 1 1.O0E÷SO I 1.00E+O0 2.90E-10 0.83 8.25E-01 0.38 3.81EE01 1.01E-06 1
8.85E-03 0.5 5.00E-01 2.10E-03 2.10fE-03 1 1.O0E+00 I 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 0.88 8.78&-01 1 1.00E+00 1.14E-04 1.14E-04 I 1.0OE+00 I 1.00E+00 2.86E-10 1-01E-06 1 8.85E-03 1 1.00E+00 0.02 1.67E-02 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.00E+00 1 1.00E+00 2.80E-10 5.19E-03 5.19E-03 1 1-93E+00 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-O1 0.42 4.21E-E1 3.28E-03 3.28E-03 0.02 2.47E-02 0.0E 4.55E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 2.80E-10 5.19E-03 5.19E-03 1 1893E+00 1 1.00E+S0 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 3.28E-03 3.281-03 0.02 2.47E-02 0.05 4.55E-02 0.04 3.56E-02 1 1.00E+00 1 1.0OE+00 2.80E-10 1.01E-O6 1 8.85E-03 1 1.OCE+00 1 1.00E800 0.88 8.76E-01 0.97 8.67E-01 0.05 5.002-02 5.00E-03 1 5.00E-O3 1 1.00E+00 3.28E-03 3.28E-03 0.05 4-5$E-02 1 1.00E+00 1 1.0OE+00 2.80E-10 1.01E-E6 1 8.85E-03 I 1.00E+00 I 1.OOEv00 0.88 8.76f-El 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1 5.00fE-E3 1 1.00E+00 3.28E-03 3.28ff-03 0.05 4.55E-02 1 1.00E+00 1 1.00E+00 2.78E-10 0.02 2.29E-02 0.01 1.48E-02 1.07E-07 87624 8.38E-03 1 1.00E+00 0.88 8g76E-01 1.00E-04 1.00f-4 1 1.00E+00 1 1.0E+00 2.77E-10 0.83 8.25E-E1 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E-00 3.00E-03 3.00E-03 I
9.97E-01 I 1.00E+00 0.88 8.76E-01
SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run 1.21E-o4 1.21E-04 SWTODG TRANSX 182 T10000SW ACAASO-50A ACLOPNOSI2 ACLOPRT767 ACTRAINA AXHFLSAFWB DGIANOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 183 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1BNR SWAASWPIDR SWCCPUMPSS SWMMSWPDRI SWTMPUMP1B TRANSX 184 T10000SW ACAAS0_50A ACLOPNOS12 ACLOPRTALL ACTRAINA AXHFLSAFWE DGIANOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 185 T10000SW ACAASO_50A ACLOPNOSI2 ACLOPRTALL ACTRAINE AXHFLSAFWA DG1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 186 T10000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPIFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWMMOSWPBS SWTMPUMP1D 187 T10000SW AXHFDSAFWX FSAZCORR03 NOSBO PCF SWAASWP1AR SWAASWP1CR SWMMOSWPDS SWMMSWPARI SWMMSWPCRI SWTMPUMPIB TRANSX 188 T10000SW ACAAS_050A ACAZDLOSP1 ACB2FIBS17 ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINE AFAX1TDAFW DG1ANOTRUN DGIENOTRUN PCF SBO SWMM0SWPCS SWTMPUMP1A SWTODG 189 T10000SW AAAATRANSI ACMMSST016 ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DG1BNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR SWrODG 190 TIOOOOSW ACAA50 O0A ACAZDLOSP1 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFHFDALTrTD DGIANOTRUN TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Failure to restore SAFW Pump Train lD to service post test/maint FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG -TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correotly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG -NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01B Is Not In Operation FLAG - Service Water Pump PSW01 D Is In Operation Common Cause Failure Of Service Water Pumps To Start FAILURES OF SW PUMP D TO RUN SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Site Power Following Reactor Trip TAG - Failure of AC Train A Failure to mrtow SAFW Pump Train ID to service post testimaint FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train B Failure to restore SAFW Pump Train IC to service post test/maint FLAG. DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG. TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP B TO START SW Pump D in maintenance Total Loss of Service Water Operators Fail to Correctiy Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01A Is In Operation FLAG - Service Water Pump PSWOIC Is In Operation FAILURES OF SW PUMP D TO START FAILURES OF SERVICE WATER PUMP A TO RUN FAILURES OF SW PUMP C TO RUN SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Falure to Restore Ofnsite Power Wthin I Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Alt Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG-DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A In maintenance TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Resuots in SI Conditions (Seal LOCA)
Transformer PXABSS016 Faults TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
Falure to Restore Offste Power Wohin I Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B OPERATORS FAIL TO PROVIDE COOLING TO TDAFW LUBE OIL FROM DIESEL FIRE PUMP FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 I 1.OOE+00 1 1.00E+O0 1 1 00E800 2.77E-10 083 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.O0E+00 3.00E-03 3.00-E03 1 9.97E-01 I 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E-00 I 1_000+00 I 1.00E+00 2.74E-10 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 1.14E-04 1.14E-04 0.02 2.47E-02 0.05 4.55E-02 I 1.0E+00 1 1.08E+00 2.74E-10 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 3.00-E03 3.00E-03 1 9.97E-01 1 1.0OE+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00>E00 1 1.00E+00 2.74E-10 0.83 8.25E-01 05 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 3.00E-03 3.008-03 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 2.73E-10 1 1.00E800 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 1 100E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 3.28E-03 3.28E-03 7.15E-03 7.15E-03 1 1.08E+00 2.88E-10 5.19E-03 5.19E-03 1 1.93E+00 1 1.0E+00 0.88 8.76E-01 0.58 5.78E-01 0.58 5.79E-01 3.28E-03 3.28E-03 0.02 2.47E-02 0.02 2.47E-02 0.05 4.55E-02 I 1.00E+00 1 1.0OE+00 2.61E-10 0.83 8.258E-01 0.38 3.81E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 8.97E-01 1 9.97E-01 0.88 8.76E-01 1 I.00E+00 3-28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 1 1.00E+00 2.42E-10 1 1.00E800 8.40E-05 8.40E-05 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E800 1.21E-04 1.21E-04 1 1.00E+00 I 1.00E+80 2.32E-10 0.83 8.25E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+0 1 1.00E+00 6.70E-03 6.70E-03 1 9.97E-01
DG1SNOTRUN PCF SBO SWCCIPUMPSR SWTODG 191 TIEOOWOS AXCCPDISCB NOSBO PCF SWCCIPUMPSR TRANSX 192 TI0000SW ACAA5050A ACLOPNOSI2 ACLOPRT751 ACTRAINB AXHFLSAFWA DGIBNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 193 TI000OSW ACAAS 50A ACLOPNOSI2 ACLOPRT767 ACTRAINA AXHFLSAFWS DGIANOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 194 TI0000SW ACAA50E50A ACLOPNOS12 ACLOPRTALL.
ACTRAINA AXHFLSAFWB DGlANOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 195 TI00OOSW ACAA50_50A ACLOPNOSI2 ACLOPRTALL ACTRAINB AXHFLSAFWA DGIBNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX 196 TI000OSW ACB2FIBS17 ACTRAINB AXTMSAFSGA AXTMSAFSGB NOSBO PCF SWMMOSWPAS SWTMPUMP1C TRANSX 197 TI00SOSW ACB2FIBS17 ACTRAINB NOSBO PCF RCAZD0051 SN RCHFDPLOCA RCRZT0431C SLO SWMMOSWPAS SWTMPUMP1C TLSTRANS 198 TI000SOW ACB2FIBS17 ACTRAINB NOSBO PCF RCAZD00516N RCHFOPLOCA RCRZT00430 SLO SWMMOSWPAS SWTMPUMP1C TLSTRANS 199 T10000SW ACB2FIBS17 ACTRAINB AXTMSAFSGA AXTMSAFSGB NOSBO PCF SWCCPUMPSS TRANSX 200 TIOOOSOW ACB2FIBS18 ACTRAINA AXTMSAFSGA AXTMSAFSGB NOSBO PCF SWCCPUMPSS TRANSX 201 T10000SW AXHFDSAFWX FSAZCORR03 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 19 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water Common cause failure of check valves 9700A and 9700B to open TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsie Ciruit 751 Following Reactor Tnp TAG - Failure of AC Train B Failure to restore SAFW Pump Train IC to service post test/maint FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A Failure to restore SAFW Pump Train 1D to service post test/maint FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 797 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train A Failure to restore SAFW Pump Train I D to service post test/maint FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 19 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Sae Power Following Reactor Trip TAG - Failure of AC Train B Failure to restore SAFW Pump Train IC to service post test/maint FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 19 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Faunt on 480 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C lv maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM SAFW TRAIN D TO S/G B O.O.S. DUE TO TIM TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M SAFW TRAIN D TO S/G B 9.0.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT EVENT Total Loss of Service Waler Operators Fail to Correctly Align SAFW (Corrected for TIO0OOSW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.OE+00 1 1.009E+0 2.31E-10 2.18E-06 2.18E-06 I 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.0IEu00 2.29E-10 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 3.00E-03 3.00E-03 1 9.97E.01 1 1.00E+00 0.88 8.76E-01 1.90E-04 1.00E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 2.29E-10 0.83 8.25$-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.08E+00 3.00E-03 3.00E-03 1 9.97E-01 1 1.00Eu00 0.88 8.78E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00Eu00 1 1.00E+00 2.27E810 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.90E+00 3.00E-03 3.0OE-03 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1I 1.00E+00 1 1.08E÷00 1 1.00E+00 2.27E-10 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.106-03 1 1.00E+00 3.00E-03 3.00E-03 1 9.97E-01 1 1.90E+00 0.88 8.76E-01 1.00E-04 I.08E-04 1 1.00+O00 1 1.00E+00 I 1.00E+00 2.24E-10 1.01E-06 I 8.85E-03 1 1.00E+00 0.02 1-67E-02 0.01 1.48E-02 1 1.00E+00 0.88 8.78E-01 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 I 1.0OE+00 2.19E-10 1.01E-06 I 8.85E-03 1 1.00E+00 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5-00E-02 5.00E-03 1 5.00E-03 1 1.00E+00 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.008E00 1 1.00E+00 2.19E-10 1.01 E06 I
8.85E-03 I 1.00uE00 1 1.00E800 0.88 8.76E-01 0.97 9.67E-01 0.05 500OE-02 5.00E-03 1 5.00-E03 1 1.00E+00 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 2.19E-10 1.01E-06 1 8.85E-03 1 1.00E+00 0.02 1.67E-02 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.00E+00 2.19E-10 1.01E-06 1 8.85E-03 1 1.00E+00 0.02 1.67E-02 0.01 1.48E-02 1 1.00E-00 0.88 8.76E-01 1.14E-04 1.14E-04 I 1.00E800 1 1.00E+00 2.14E-10 5.19E-03 5.19E-03 1 1.93E+00
NOSBO PCF SWAASWPIAR SWAASWP1CNR SWCCPUMPSS SWMMSWPARI SWTMPUMPIC TRANSX 202 TIOOOOSW ACE2FIBS17 ACTRAINB NOSBO PCF RCAZDOO515N RCHFDPLOCA RCRZTO431C SLO SWCCPUMPSS TLSTRANS 203 TI000SW ACB2FIBSI7 ACTRAINB NOSBO PCF RCAZDOO0516N RCHFDPLOCA RCRZT0O430 SLO SWCCPUMPSS TLSTRANS 204 TI0000SW ACB2FIBS18 ACTRAINA NOSBO PCF RCAZD00515N RCHFDPLOCA RCRZT0431C SLO SWCCPUMPSS TLSTRANS 205 TIOO0SW ACB2FIBS18 ACTRAINA NOSBO PCF RCAZD00516N RCHFDPLOCA RCRZTO0430 SLO SWCCPUMPSS TLSTRANS 206 T100000SW AAAATRANSI ACAA50_50A ACLOPNOS12 ACLOPRT767 CVHFDSUCTN IAAACSA02R IAHFDCSA04 NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR 207 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1BR SWAASWPIDR SWMMOSWPAS SWMMSWPBRI SWMMSWPDRI SWTMPUMPI C TRANSX 208 T10000SW AAAATRANSI ACAA50_50A ACLOPNOS12 ACLOPRTALL CVHFDSUCTN IAAACSA02R IAHFDCSAO4 NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWCCIPUMPSR 209 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWPIAR SWAASWP1CR SWCCPUMPSS SWMMSWPARI SWMMSWPCRI TRANSX 210 T1000OSW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1BR SWAASWP1DR SWCCPUMPSS SWMMSWPBRI SWMMSWPDRI TRANSX TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01A Is In Operation FLAG - Service Water Pump PSWOIC Is Not In Operation Common Cause Failure Of Service Water Pumps To Start FAILURES OF SERVICE WATER PUMP A TO RUN SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 400 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA W/n 3 Min PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Seivice Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA W/in 3 Min PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Operators Fall To Close PORV Block Valve (515/516) To Terminate LOCA W/ln 3 Min PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Serorvce Water Pumps To Start TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failuro of AC Train A TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Totat Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip Operators Fail to Manually Open Suction Line Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR 5 I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corected for TIOOOOSW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWO1 B Is In Operation FLAG -Service Water Pump PSWO1 D Is In Operation FAILURES OF SW PUMP A TO START FAILURES OF SW PUMP B TO RUN FAILURES OF SW PUMP D TO RUN SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor T
rip Operators Fail to Manually Open Suction Line Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR 0 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for TIOOOOSW and Soei Fire Events For Stress)
CoTrection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWO1A Is In Operation FLAG - Service Water Pump PSWO1C Is In Operation Common Cause Failure Of Service Water Pumps To Start FAILURES OF SERVICE WATER PUMP A TO RUN FAILURES OF SW PUMP C TO RUN TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for TIOO0OSW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW0IB Is In Operation FLAG - Service Water Pump PSW01D Is In Operation Common Cause Failure Of Service Water Pumps To Start FAILURES OF SW PUMP B TO RUN FAILURES OF SW PUMP D TO RUN TAG - TRANSIENT EVENT 1 1.0OE+00 0.85 8.76E-01 0.58 5.79E-01 0.42 4.21E-01 1.14E-G4 1.14E-04 0.02 2.47E-02 0.04 3.56E-02 1 1.001+00 1 1.OOE+0O 2.14E-10 1.01E-06 I
8.85E-03 1 1.gOE+0g 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.OE-03 1 5.00E-03 1 1.00E+00 1.14E-04 1.14E-04 I 1.00E+O0 I 1.00E+00 2.14E-10 1.01E-06 1 8.85E-03 1 1.00E+00 1 1.0OEo00 0.88 8.76E-01 0.97 9.67E-01 0.05 0.003E-02 5.00E-03 1 5.00E-03 1 1.00E+00 1.14E-04 1.14E-04 1 1.00E+00 1 1.00E+00 2.14E-10 101E-06 1 8.85E-03 1 1.00E+00 1 1 00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 1 1.00E+00 1.14E-04 1.14E-04 1 1.00OE+00 1 1.00E+00 2.14E-10 1.01E-06 I 8.85E-03 1 1.00E+00 I 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 1 1.00E+00 1.14E-04 1.14E-04 I 1.00E+00 1 1.00E+00 2.11E-10 1 I.000000 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 0.02 2.40E-02 0.95 9.50E-01 0.1 1.00E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E÷00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 2.09E-10 5.19E-03 5.19E-03 I 1.93E+00 1 1.00E00 0.88 8.76E-01 0-58 5.79E-01 0.58 5.79E-01 3.28E-03 3.281-03 0.02 2.47E-02 0.02 2.47E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 2.09E-10 1 1.000000 0.83 8.25E-01 0.5 5.00E-01 2.100-03 2.10E-03 0.02 2.40E-02 0.95 9.50E-01 0.1 1.00E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E÷00 1 1.O0E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 2.05E-10 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0158 5.79E-01 0.58 5.79E-01 1.14E-04 1.14E-04 0.02 2.47E-02 0.02 2.47E-02 1 1.00E+O0 1 1.00E+00 2.05E-10 5.19E-03 5.19E-03 I 1.93E+00O 1 1,00E+OO 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 1.14E-04 1.14E-0-4 0.02 2-47E-02 0.02 2.47E-02 1 1.00E+O00
211 TI0000SW Total Loss of Service Water I 1.00E+00 2.03E-10 ACMMSST014 ACTRAINA AXMMSAFWPD DGlANOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX 212 T10000SW ACMMSST018 ACTRAINE AXMMSAFWPC DGIBNOTRUN NOSSO PCF SWCCIPUMPSR SWTODG TRANSX 213 TI0000SW AXHFLSAFWA AXMMSGBSAF NOSBO PCF SWCCIPUMPSR TRANSX 214 TI700OSW AAAATRANSI ACMMSST018 ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DG1 BNOTRUN NOSEO PCF RCAZ001 RCP SEALLOCA SSLO SWCXXSUCTI SWTODG 215 T10000SW ACB2FIBS17 ACTRAINE AXTMSAFSGA AXTMSAFSG8 NOSBE PCF SWMMOSWPCS SWTMPUMPIA TRANSX 216 T10000SW ACAA50_50A ACAZOLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFHFDAL'TD DGIANOTRUN DGIBNOTRUN PCF SB SWCXXSUCTI SWTODG 217 Ti0000SW ACB2FIBS17 ACTRAINE NOSBO PCF RCAZDD0515N RCHFDPLOCA RCRZT0431C SLO SWMMOSWPCS SWTMPUMPIA TLSTRANS 218 T10000SW ACB2FIBS17 ACTRAINB NOSBO PCF RCAZD00516N RCHFDPLOCA RCRZT00430 SLO SWMMOSWPCS SWTMPUMP1A TLSTRANS 219 T10000SW AXCCPDISCB NOSBO PCF SWCXXSUCTI TRANSX 220 T10000SW ACAA5M050A ACAZOLOSPt ACB2FIBS17 ACB2FTES18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAX1TDAFW DGIANOTRUN OG18NOTRUN PCF SBO SWTODG 221 TI0000SW ACAAS0_50A ACAZDLOSP1 480 VAC Bus 14 Transformer PXABSS014 Faults TAG - Failure of AC Train A Failure of SAFW Pump ID Train FLAG. DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water Transformer PXABSS016 Faults TAG - Failure of AC Train B Failure of SAFW Pump I C train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water Failure to restore SAFW Pump Train 1C to service post tlesUmaint Failure of SAFW injection line to SIG B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Transformer PXABSS016 Faults TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B SAFW TRAIN C TO SIG A O.O.S. DUE TO T/M SAFW TRAIN D TO S/G B OO.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Offsie Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B OPERATORS FAIL TO PROVIDE COOLING TO TDAFW LUBE OIL FROM DIESEL FIRE PUMP FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water Local Faul on 480 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Operators Fail To Close PORV Block Valve (515/516) To Terminate LOCA WAn 3 Min PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage Operators Fail To Close PORV Block Valve (5150516) To Terminate LOCA W/In 3 Min PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Common cause failure of check valons 9700A and 9700B to open TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Wirtin 1 Hour Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TAG - SW Lost to 00 (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/00 ALT (CKT 751 TO BUS 128. CKT 787 TO BUS 12A)
Failure to Restore Ofsitle Power Within 1 Hour 8.40E-05 8.40E-05 I
1.00E+00 0.02 2.291-02 I
9.97E-01 1 1.00E-00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1 1.00E+00 2.03E-10 8.40E-05 8.40E-05 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E÷00 1 1.00E+00 2.03E-10 3.OOE-03 3.00E-03 6.39E-04 8.39E-04 I 1.00E+00 0.88 8.76E-01 121E-04 1.21E-04 1 1.00E+00 I 1.00E+00 2.01E-10 1 1.00E+00 8.40E-05 0.40E-05 I 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.0E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E-00 1 1.00E+00 1.97E-10 1.01 E-06 1 8.85E-03 I 1.00E+00 0.02 1.671-02 0.01 1.48E-02 I 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.03 3.13E-02 1 1-00E+00 I 1.00E+00 1.93E-10 0.83 8.25E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 8.70E-03 6.70E-03 1 997E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.000-04 1.00E-04 1 10OE+00 I 1.00E+00 1.82E-10 1.01E-06 1 8.85E-03 1 1.00E000 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 I
5000E-03 1 1.00E+00 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 1 1 00E+00 1.92E-10 1.01 0-06 1 8.850-03 1 1.00E+00 1 1.00E+00 0.88 8.761-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1
5.00E-03 1 1.00E+00 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 1 1.00E+00 1.91E-10 2.1 E-06 2.18E-06 1 1.00E+00 0.88 8.76E-01 1.00-E04 1.00E-04 1 1.OSE+00 1 1.00E+00 1.85E-10 0.83 8.25E-01 0.38 3.81E-01 1.010-06 1 8.85E-03 1.01E-06 72 7.27E-05 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E000 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.85E-10 0.83 8.25E-01 0.38 3.81E-01
ACB2FIBS18 ACB2FTBS1 7 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAXITDAFW DGIANOTRUN DGIBNOTRUN PCIF SBO SWTODG 222 TI0OO$SW ACB2FIBS18 ACTRAINA AXXVN09728 NOSBO PCF SWMMOSWPBS SWrMPUMP1D TRANSX 223 T1000OSW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPIFP NOSBO PCIF RCAZOCIRCP SEALLOCA SSLO SWAASWPICR SWCVC04803 SWTMPUMPIB 224 TIO000SW AXMMSAFWPD AXTMSAFSGA AXTMSAFWAB NOSBO PCIF SWCCIPUMPSR TRANSX 225 TI1000SW AAAATRANSI ACAAS0 50A ACLOPNOSI2 ACLOPRT767 CVHFDSUCTN LAACSA02R IAHFDCSA04 NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWC)XXSUCTI 226 TI0000SW AAAATRANSI ACAASO_50A ACLOPNOSI2 ACLOPRTALL CVHFDSUCTN IAAACSA02R IAHFDCSA04 NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCXXSUCTI 227 T10000SW ACAA50_50A ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINE AFAZFAILXX AFTMOTDAFW DG1ANOTRUN DGIBNOTRUN PCF SBO SWCCIPUMPSR SWTODG 228 TIOOOOSW ACMMSST014 ACTRAINA AXMMSAFWPD DG1ANOTRUN NOSBO PCIF SWCXXSUCTI SWTODG TRANSX 229 T10000SW ACMMSST016 ACTRAINB AXMMSAFWPC DGIBNOTRUN NOSBO PCIF SWCXXSUCTI SWTODG TRANSX 230 TI00SOSW AXHFLSAFWA AXMMSGBSAF NOSBO PCF SWCXXSUCTI TRANSX 231 T1000$SW AXHFLSAFWB AXMMSGASAF Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Sete Power Following ReactorTrp TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TAG - SW Lost to DG (cooling)
Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP S TO START SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Whichi Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSWO1C Is In Operation Service Water Pump PSW01C Discharge Check Valve 4603 Fails To Close On Demand SW Pump B in maintenance Total Loss of Service Water Failure of SAFW Pump 1 D Train SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM SAFW cross-connect line out-of-service for maintenance TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Top Operators Fail to Manually Open Suction Line Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-See Power Following Reactor Trip Operators Fail to Manually Open Suction Line Upon Loss of IA FLAG - SA COMPRESSOR CSA02 RUNNING AND SUPPLYING IA OPERATORS FAIL TO PLACE THE DIESEL AIR COMPRESSOR IN SERVICE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 126. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Sie Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
TDAFW Pump Train out-of-service for maintenance FLAG - DO; 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water 480 VAC Bus 14 Transformer PXABSS014 Faults TAG - Failure of AC Train A Failure of SAFW Pump ID Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water Transformer PXABSS016 Faults TAG - Failure of AC Train B Failure of SAFW Pump 1C train FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water Failure to restore SAFW Pump Train IC to service pest test/maint Failure of SAFW injection line to S/G B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water Failure to restore SAFW Pump Train ID to service pest test/maint Failure of SAFW injection line to S/G A 1.01E-06 1 8.85E-O3 1.01E-06 72 7.27E-O5 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.001+00 1 t.00E+00 1 1.00E+00 1 9.97E-01 I
9.97E-01 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 182E-10 1.01 E-06 1 8.85E-03 1 1.00E+00 1.00E-03 1 1.00E-03 1 1.00E+O0 0g88 8.76E-01 3.28E-03 3.28E-03 7.15E-03 7.15E-03 1 1.00>E00 1 1+008E00 1.79E-10 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.58 5.79E-01 5+84E-04 1 5.84E-04 0.05 4.55E-02 1 1.00E+00 1.75E-10 0.02 2.29E-02 0.02 1.87E-02 4.33E-03 4233E-03 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1.75E610 1 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 0.02 2.40E-02 0.95 9.50E-01 0.1 1.0OE-01 1 1006E+00 0.88 8.76E801 1 1.00E+00 1 1.00E+00 1 1.00E800 1.00E-04 1.00E-04 1 1.00E+00 1.73E-10 I 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10-E03 0.02 2.40E-02 0.95 9850E-01 0.1 1.00E-01 1 1.00E+00 0.88 8,76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 1.73E-10 0.83 8.25E-01 0.5 5.00E-O1 2.10E-03 2-10E-03 1 1.00>E00 1 1.00E+00 0.1 1.00E-01 0.02 1.90E-02 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 I 1.00E+00 1.21E-04 1.21E-04 1 1008+00 1 1.00E+00 1.68E.10 8.40E-05 8.40E-05 1 1.00E+00 0.02 2.29E-02 1 9897E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E600 1 1 00E+00 1 1.00E+00 1.68E-10 8.40E-05 840E-05 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 I 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 I 1.00E+00 1 1.00E+00 1.801-10 3.00E-03 3.00E-03 6.39E-04 6.38E-04 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 1.58E-10 3.00E-03 3.00E-03 4.976E-04 4.97E-04
NOSBO PCF SWCCIPUMPSR TRANSX 232 TI0000SW AXMMSAFWPC AXTMSAFSOB AXTMSAFWAB NOSBO PCF SWCCIPUMPSR TRANSX 233 TI0000SW AXMMSAFWPD AXTMSAFSGA AXTMSAFWAB NOSO PCF SWCXXSUCTI TRANSX 234 TI0000SW ACAA50-50A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX AFTMOTDAFW DG1ANOTRUN DGIBNOTRUN PCF SBO SWCXXSUCTI SWTODOG 235 TI000OSW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCAZSO1 RCP SEALLOCA SSLO SWAASWP1BR SWCVC04602 SWTMPUMP1C 238 TIOOOOSW ACMMMCCO1C AXMMSAFWPO NOSBO PCF SWCCIPUMPSR TRANSX 237 TI00COSW ACMMMCCOIL AXMMSAFWPD NOSBO PCF SWCCIPUMPSR TRANSX 238 TI0000SW ACMMMCCO1D AXMMSAFWPC NOSBO PCF SWCCIPUMPSR TRANSX 239 TIO000SW ACMMMCC01M AXMMSAFWPC NOSBO PCF SWCCIPUMPSR TRANSX 240 TI0000SW AXHFLSAFWB AXMMSGASAF NOSBO PCF SWCXXSUCTI TRANSX 241 TIOOOSW AXMMSAFWPC AXTMSAFSGB AXTMSAFWAB NOSBO PCF SWCXXSUCTI TRANSX 242 T10000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWMMOSWPAS SWMMOSWPCS 243 TIOO8OSW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPIFP NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWMMOSWPSS SWMMOSWPDS TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water Failure of SAFW Pump 1C train SAW* TRAIN D TO IOG B O.O.S. DUE TO T/M SAFW cross-cornect line out-of-serurce for maintenance TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water Failure of SAFW Pump 1D Train SAFW TRAIN C TO S/G A DO..S. DUE TO TIM SAFW cross-connect line out-of-service for maintenance TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
TDAFW Pump Train out-of-service for maintenance FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR v 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSW01B Is In Operation Service Water Pump PSW01 Discharge Check Valve 4602 Falls To Close On Demand SW Pump C in maintenance Total Loss of Service Water 480 VAC Motor Control Center MCCC Faults Failure of SAFW Pump 1 D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water 480 VAC Motor Control Center MCCL Fauots Failure of SAFW Pump ID Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water 480 VAC Motor Control Center MCCD Faults Failure of SAFW Pump 1C train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water 480 VAC Motor Control Center MCCM Faults Failure of SAFW Pump 1C train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT Total Loss of Service Water Failure to restore SAFW Pump Train 1D to service pest test/maint Failure of SAFW injection line to S/G A TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water Failure of SAFW Pump 1C train SAFW TRAIN D TO SIG B O.O.S. DUE TO TJM SAFW cross-connect line out-of-service for maintenance TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START FAILURES OF SW PUMP C TO START Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP B TO START FAILURES OF SW PUMP D TO START 1 I.0OE>00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E-00 1 1.001E+O0 1.58E-10 0.02 2.29E-02 0.01 1.480-02 4.33E-03 4.33S-03 1 1l00E÷00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E>00 1 1.OE+O0 1.458E-10 0.02 2.29E-02 0.02 1.678-02 4.33E-03 4.33E-03 1 1.0OE+00 0.88 8.76E-01 1.00E-04 1.000-04 1 1.0OE+00 1 1.00E+00 1.438-10 0.83 8.25E-01 0.5 5.001-01 2.10E-03 2.108-03 I 1.00E÷00 1 1.DOE+00 0.1 1.00-E01 0.02 1.90E-02 1 9.978-01 1 9.97E-01 0.88 8.76E-01 I 1.00E-00 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 1.40E-10 1 1.00E+00 1.01E-06 1 8.85lt-03 1 1.08E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 0.78-E01 1 1.00E+00 1 1.00E+00 1 1.00E+v0 0.58 5.79E-01 l.84E-04 1 5.84E-04 0.04 3.56E-02 1 1.,OE+00 1.36E-10 5.82E-05 5.82E-05 0.02 2.29E-02 1 1.00E+00 0.88 8.78E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1 00vE00 1.36E-10 5.62E-05 5.82E-05 0.02 2.29E-02 1 1.00E÷00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E1200 I 1.00E+00 1.36E810 5.62E-05 5.62E-08 0.02 2.29E-02 I 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E>00 1.36E-10 lt62E-05 5.62E-05 0.02 2.29E-02 1 1.008+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1.31E-10 3.00E-03 3.00E-03 4.97E-04 4.97E-04 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.0OE-04 1 1.00E÷00 1 1.00E+00 1.28E-10 0.02 2.29E-02 0.01 1.48E-02 4.338-03 4.33E-03 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 1.25E-10 I 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 I 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.00E+00 1 1.O0E+00 3.28E-03 3.28E-03 3.28E-03 3.28E-03 I 1.00E+00 1.25E-10 1 1.00E+00 1-01E-08 1 8.85E-03 I 1.00E+00 1.50E-03 1.50E-03 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 I 1.o0E÷00 1 1.00E+00 3.28E-03 3.28E-03 3.28E-03 3.28E-03
244 TI0000SW MLO PCF RCAZD00515N RCAZD00516N RCHFOPLOCA RCRZT00430 RCRZT0431C SWCCIPUMPSR TLMTRANS 245 Ti0000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCAZ001RCP SEALLOCA 5SLO SWAASWP1DR SWCVC04804 SWPMPDINIT SWTMPUMPIA 246 TI0000SW AAAATRANSI ACAASOL50A ACLOPNOSI2 ACLOPRT751 ACTRAINB CVMMPCH1AF DG1BNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 247 TI0000SW AAAATRANSI ACAASO 50A ACLOPNOS12 ACLOPRTALL ACTRAINB CVMMPCHIAF DG1BNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG 248 TI000OSW ACB2FIBS18 ACTRAINA AXXVN09728 NOSBO PCF SWAASWPICR SWCVC04603 SWTMPUMP1B TRANSX 249 TI00OOSW ACAA10.OX ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFTMOTDAFW DGIANOTRUN DGIBNOTRUN PCF
$50 SWCCIPUMPSR SWTODG 250 TI0000SW ACMMMCC01C AXMMSAFWPD NOSBO PCF SWCXXSUCTI TRANSX 251 TI0000SW ACMMMCC0IL AXMMSAFWPD NOSBO PCF SWCXXSUCTl TRANSX 252 TI0OO0SW ACMMMCCOI D AXMMSAFWPC NOSBO PCF SWC)CXSUCTI TRANSX 253 TIO000SW ACMMMCC01M AXMMSAFWPC NOSBO PCF SwaOSUCTI TRANSX 254 110000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPIFP NOSBO PCF RCAZ001RCP Total Loss of Service Water TAG - MEDIUM LOCA SEQUENCE PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Moltr-Operated Valve 516 Is Not Closed Due To PORV Leakage Operators Fail To Close PORV Block Vatve (5151518) To Terminate LOCA W/In 3 Min PORV PCV-430 Fails To Reseat After Steam Relief PORV PCV-431C Fails To Reseat After Steam Relief Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In St Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSW01 0 Ic tn Operation Service Water Pump PSWO1D Discharge Check Valve 4804 Fails To Close On Demand TAG - SW PUMP D FAILS AS AN INITIATING EVENT SW Pump A in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactr Trip TAG - Failure of AC Train B CHARGING PUMP PCH01A FAILS TO RUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Caose Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Sie Power Fotlowing Reactor Tdip TAG - Failure of AC Train B CHARGING PUMP PCHO0A FAILS TO RUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR, 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01C Is In Operation Service Water Pump PSWS1C Discharge Check Valve 4803 Fails To Close On Demand SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Failure to Restore Offslel Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-S8e Power FolokMng Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TDAFW Pump Train oat-of-service for maintenance FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Caose Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
Total Loss of Service Water 480 VAC Motor Control Center MCCC Faults Faire of SAFW Pump ID Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION QNITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water 480 VAC Motor Control Center MCCL Faults Failure of SAFW Pump I D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water 480 VAC Motor Control Ceoter MCCD Faults Failure of SAFW Pump 1C train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON 5W/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water 480 VAC Motor Control Center MCCM Faults Failure of SAFW Pump IC train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR)
TAG - TRANSIENT EVENT Total Loss of Service Water TAG - Transient Initiating Event Which Eventualay Results In SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 1.24E-10 1 1.00E+00 0.88 8.76E-01 0.97 9.87E-01 0.97 9.67E-01 0.05 5.00E-02 5.02E-03 1 5.00E-03 5.OE-03 1 5.00E-03 1.21E-04 1.21E-04 I 1.00E+00 I 1.00E+00 1.23E-10 I 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E-00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 I 1.00E+00 1 1.00E+00 0.58 5.79E-01 5.84E-04 1 5.84E-04 1 1.005+00 0.03 3.13E-02 1 1.005+00 1.21-110 1 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 I 1.00E+00 1.31E-03 1.311-03 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1.20E-10 1 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.102-03 2.10E-03 I 1.00E+00 1.315-03 1.31E-03 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.00E+00 1 1.OOE+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1.19E-10 1.01E-06 1
.85E-03 1 1.00E+00 1.00E-03 1 1.00E-03 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 5.84E-04 1 5.84E-04 0.05 4.55E-02 1 1.00E+00 I 1.00E+00 1.1SE-10 0.14 1.44E-01 0.38 3.81E-01 0.5 5.00E-01 2.1OE-03 2.10E-03 1 1.00E+00 I 1.00E+00 0.02 1.90E-02 I 9.97E-01 I 9.97E-01 0.88 8.76E-01 1 1.005+00 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 1.13E-10 5.62E-05 5.625-05 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 1.13E-10 5.62E-05 5.82E-05 0.02 2.29E-02 I 1.00E+80 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.005+00 1 1.00E+00 1.13E-10 5.62E-05 5.62E-05 0.02 2.29E-02 I 1.00E+00 0.88 8.78E-01 1.00E-04 1.00E-04 1 1.00E+00 I 1.00E+00 1.13E-10 5.62E-05 5.82E-05 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 1.08E-10 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.602-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 I 1.00E+00
SEALLOCA SSLO SWMMSWPDRT SWTMPUMPIB 255 TI0000SW ACAA5S050A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS AFAZFAILXX AFMMOTDAFW DGIANOTRUN DGIBNOTRUN PCF
$50 SWCCIPUMPSR SWTODG 256 TIOOOOSW ACAAS0_SOA ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAX1TDAFW DG1ARUN DGIBNOTRUN DGAZRUNDGA PCF SO SWCCIPUMPSR SWTODG 257 TI00OOSW ACAA50_50A ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFHFLTDAFW DG1ANOTRUN DG1BNOTRUN PCF SBO SWCCIPUMPSR SWTODG 258 TIOOOOSW MLO PCF RCAZD00515N RCAZD00518N RCHFDPLOCA RCRZT00430 RCRZT0431C SWCXXSUCTI TLMTRANS 259 T10000SW ACB2FIBS18 ACTRAINA AXCCSSAFWA NOSBO PCF SWMMOSWPDS SWTMPUMP1B TRANSX 263 TIO000SW AAAATRANSI AAA..OOSX ACB2FIBS17 ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DGIANOTRUN DG1SNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SVWTMPUMP1A SWTMPUMPIC SWTODG AAAA ACHFDRCOFF 264 TIO000SW AAAATRANSI ACAA0M100X ACS2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWTMIPUMP1A SWTMPUMPIC SWTODG AAAA 265 T10000SW AAAATRANSI ACAA0100X ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINS DGIANOTRUN DGIBNOTRUN TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 TAG - SMALL SMALL LOCA SEQUENCE I 11.00E00 FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 SW Pump S in maintenance 0.05 4.55E-02 Total Loss of Service Water 1 1.00E+00 1.07E-10 FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 8.25E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of All Off-Site Power Following ReactoriTdp 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure ofAC Train B I 1.00E+00 Non-Elec Failure of aDl MDAFW pumps oindependent of AF300) 0.1 1.00E-01 Failure of TDAFW pump traie components 0.01 1.17E-02 FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 Total Loss of Service Water I 1.00E+00 1.045-10 FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 Failure to Restore Offsie Power Within 1 Hour 0.38 3.81E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Losw of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Faoure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 TAG - TDAFW Pump operates successfully 1 1.00E+00 FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 0.03 3.00E-02 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.005-01 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - STATION BLACKOUT SEQUENCE 1 1.005200 Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TAG - SW Lost to DG (cooling) 1 1.00+200 Total Loss of Service Water 1 1.00E+00 1.045-10 FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 Failure to Restore Offste Power Within 1 Hour 0.38 3.81E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.005-01 Loss of AN Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 Failure to restore TDAFW pump train to service post test/maintenance 3.00E-03 3.00e-03 FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - STATION BLACKOUT SEQUENCE 1 1.005+00 Common Cause Failure Of Service Water Pumps To Run 1.215-04 1.21E-04 TAG - SW Lost to DG (cooling)
I 1.00E+00 Total Loss of Service Water I 1.00E+00 1.02E-10 TAG - MEDIUM LOCA SEQUENCE 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage 0.97 9.671-01 Motor-Opurated Valve 516 Is Not Closed Due To PORV Leakage 0.97 9.67E-01 Operators Fad To Close PORV Block Valve (515/518) To Terminate LOCA W/In 3 Min 0.05 5.00E-02 PORV PCV-430 Fails To Reseat After Steam Reitef 5.00E-03 1 5.001-03 PORV PCV-431C Fais To Reseal After Steam Relief 5.00E-03 1 5.00E-03 TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TAG - TRANSIENT INDUCED MEDIUM LOCA SEQUENCES 1 1.00E+00 Total Loss of Service Water I 1.00E+00 1.02E-10 Local Fault on 480 VAC Bus 18 1.01E-06 1 8.85E-03 TAG - Failure of AC Train A I 1.00E+00 Common couse failure of SAFW Pumps 1C and ID to start 8.79E-05 0.79E-05 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SW Pump B in maintenance 0.05 4.55E-02 TAG - TRANSIENT EVENT 1 1.00E+00 Total Loss of Service Water 1 1.00E+00 O.00E+00 TAG - Transient Initiating Event Whlich Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128) 0.02 1.501-02 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.5E-03 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of Offsite Circuit 751 Following Reactor Trip 2.12E-03 2.12E-03 TAG - Failure ofAC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT 1 1.005+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 TAG - TRANSIENT INDUCED SEAL LOAs 1 1.00E500 TAG - SMALL SMALL LOCA SEQUENCE 1 1.00+E00 SW Pump A in maintenance 0.03 3.13E-02 SWPumpC In maintenance 0.04 3.56E-02 TAG - SW Lost to DG (cooling) 1 1.00E+00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 Failure to recover second offsite power circul after failure of first 0.1 1.00E-01 Total Loss of Service Water I 1.00E+00 0.00+E00 TAG - Transient Initialing Event Which Eventualy Results in SI Conditions (Seal LOCA) 1 1.00E+00 FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 126) 0.02 1.05E-02 Local Fault on 480 VAC Bus 17 1.01E-06 I 8.85E-03 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of AN Off-Sihe Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT 1 1.005+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 NO RCP SEAL COOLING FOR > 1 HOUR 1 1.005+00 TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 SW Pump A In maintenance 0.03 3.13E-02 SW Pump C in maintenance 0.04 3.05E-02 TAG - SW Lost to DG (cooling) 1 1.00E+00 FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E500 Total Low of Service Water 1 1.00E+00 O.00E+00 TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B) 0.02 1.501-02 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of Offslte Circuit 751 Folowlig Reactor Trip 2.12E-03 2.12E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure ofAC Train B 1 1.00E+00 FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 19 AND 17 1 9.97E-01
NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCIPUMPSR Sw'rODG AAAA ACHFDRCOFF 268 TI0000SW AAAATRANSI ACAA0O100X ACLOPNOSI2 ACLOPRT-51 ACTRAINA ACTRAINS DGlANOTRUN DG1BNOTRUN NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCo(SUCTI SWTODG AAAA ACHFDRCOFF 267 TI0000SW AAAATRANSI ACAAOJL0OX ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA 268 T10000SW AAAATRANSI ACAA0J100X ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA 269 TI0000SW AAAATRANSI ACAAI00 0X ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ00IRCP SEALLOCA SSLO SWCCPUMPSS SWTODG AAAA ACHFDRCOFF 270 T10000SW AAAATRANSI ACAA100_0X ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ00IRCP SEALLOCA SSLO SWMMOSWPAS SWTMPUMP1C SWTODG AAA ACHFDRCOFF 271 T10000SW AAAATRANSI ACAA100_OX ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to D0 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Trensintl Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 0/100 (CKT 781 SUPPLYING BUSES IA AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offste Circuit 751 Following Reactor Ttip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + I HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second oftsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiaing Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Site Power Folfowing Reactor Trip TAG - Fauure ofAC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE Corrmnon Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss OfAlI Off-Sne Power Following ReactorTrip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR u 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsihe Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - 00 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOOAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG -Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offste Circuit 767 Following ReactorTnp TAG - Faiure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR + 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 0.88 8.788-01 1 1.00E+80 1 1.00E+80 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+80 0 0.OOE+00 0.1 1.002-01 1 1.00E+00 0.OOE+00 1 1.00E+00 0.02 1.50E-02 0.8 8.008-01 2.12E-03 2.121-03 1 1.00E+00 1 1.005+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.008E00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 1 1.00E+00 0.02 1.50E-02 0.5 5.00E-01 2.10E-03 2.102-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.80E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E2+0 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.001+00 1 1.00E+00 0.008+00 1 1.008+00 0.02 1.50E-02 0.8 5.00E-01 2.108-03 2.10E-03 1 1.00E+00 1 1.008+00 1 9.97E-01 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.008+00 1 1.008+00 0.00E+00 1 1.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 &.001-01 2.12E-03 2.11212-03 0 1.00E+00 1 1.00E+00 I 9.97E-01 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 I 1.00E+00 I 1.00E+00 1.14E-04 1.14E-04 I 1.00E+00 0 0.00E+00 0.1 1.0012-011 I 1.00E+00 0.00E+00 I 1.00E+O0 0.14 1.44E-01 1.01E-156 I 8.85E-03 0.5 5.00E-0t 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E÷00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E÷00 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 0 0.00E+00 0.1 1.00E-011 1 1.00E+00 0.0012+00 1 1.00E÷00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-011 2.12E-03 2.12E*03 I 1.00E+00 I 1.00E+00 1 9.97E-01 I 9.07E-01 1 1.0012+00 0.88 8.78E-01 I 1.00E÷00 I 1.00E+00
SSLO SWMMOSWPCS SWTMPUMPIA SWTODG AAAA ACHFDRCOFF 272 TI0000SW AAAATRANSI ACAA1 80X ACB2FIBS17 ACLOPNOSt2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWTMPUMPIA SWTMPUMPIC SWTODG AAAA ACHFDRCOFF 273 T10000SW AAAATRANSI ACAA100_0X AC52FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCCPUMPSS SWrODG AAAA 274 TI0000SW AAAATRANSI ACAAI00O0X ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DG1ANOTRUN DGl BNOTRUN NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWMMOSWPAS SWTMPUMP1C SWTODG AAAA 275 T10000SW AAAATRANSI ACAA100_OX ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1 BNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWVMOSWPCS SWTMPUMP1A SWTODG AAAA 276 T10000SW AAAATRANSI ACAA100.0X ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF RCAZ00IRCP SEALLOCA SSLO SWTMPUMP1A SWTIMPUMPIC SWTODG AAA 277 T10000SW AAAATRANSI ACAAI00O0X ACB2FIBS18 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGlANOTRUN DG1 BNOTRUN NOSBO PCF RCAZ001 RCP TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A In maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offste power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsfie Circuit 767 Following Reautor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 1I FLAG - 0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of M Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG-DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Inilating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 120)
Local Fault 0n 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Site Power Following Reactr Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Alt Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 16 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of An Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - 8W Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventualty Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG -DG0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.OSE+00 1 1.00E+00 0.14 1.44E-01 1.01E-00 1 8.85E-03 0.5 5.00E-01 2.128-03 2.12E-03 I 1.00E+00 1 1.001+00 I 9.97E-01 1 9.97E-01 1 1.001+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0 0.00+E00 0.1 1.00E-01 1 1.00+E00 0.00E+00 1 1.00E+00 0.14 1.44E-01 1.01E-06 1 8.68-E03 0.5 5.00E-01 2.10E-03 2.10E-03 I 1.00E+00 1 1.00E+00 1 9.07E-01 1 9.97E-01 1 1.00E+00 0.88 6.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.14E-04 1.14E-04 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10t-03 1 1.00E÷00 1 1.00E00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 I 1.00E+00 1 1.00E+00 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 O 0.00E+00 1 1.008200 0.00E+00 1 1.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E÷00 0.88 8.78E-01 1 1.00E+00 1 1.001+00 1 1.00E+00 3.28E-03 3.281-03 0.03 3.131-02 1 1.00E+00 0 0.00E200 1 1.00E+00 0.OOE+00 1 1.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E÷00 1 1.00E+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 I 1.00E+00 0 0.00E-00 1 1.00E+00 0.00E+00 1 1.00E+00 0.14 1.44E-01 1.01E-08 1 6.88E-03 0.5 5.00E-01 2.12E-03 2.121-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00
SEALLOCA SSLO SWCCPUMPSS SWTODG AAAA ACHFDRCOFF 278 T10000SW AAAATRANSI ACAA100LOX ACB2FIBS18 ACLOPNOSI2 ACLOPRT787 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWMMOSWPDS SWT'MPUMP1B SWTODG AAAA ACHFDRCOFF 279 TI0000SW AAAATRANSI ACAA1 00_OX ACB2FIBS18 ACLOPNOSI2 ACLOPRT/87 ACTRAINA ACTRAINB DGIANOTRUN DGlBNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWTMPUMPIB SWTMPUMPID SWTODG AAAA ACHFDRCOFF 280 TI0000SW AAAATRANSI ACAA100_OX ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSOB PCF RCAZ001RCP SEALLOCA SSLO SWCCPUMPSS SWTODG AMMA 281 T10000SW AAAATRANSI ACAA100_OX ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO OSWvIMOSWPDS SWTMPUMPI B SWTODG AAAA 282 TI0S0SW AAAATRANSI ACAA10 0.OX ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWTMPUMPIB SWTMPUMPID SWTODG AAAA 283 TI7000SW AAAATRANSI ACAA100_0X ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF RCAZOO1 RCP TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsie power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offaste Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DGO IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP D TO START SW Pump B in maintenance TAG - SW Lost to DO (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Fauure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initatinrg Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 767 Following Reactor Trip TAG - Failure ofAC Train A TAG - Failure of AC Train B FLAG - DOG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DOG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR v I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Whticl Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/S (CKT 767 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Los of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DOG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP D TO START SW Pump Bin mainatenance TAG - SW Lost to DOG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AM Off-Site Power Following Reactor Trip TAG - Faiure ot'AC Train A TAG - Failure ofAC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 I 1.00E+00 1.14E-04 1.14E-04 1 1.00E+00 0 0.008+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 1 1.00E+00 0.14 1.440-01 1.01E-06 1 8.85E-03 0.8 5.00E-01 2.12E-03 2.12E-03 I 1.00E+00 1 1.00E-00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 3.28E-03 3.28E-03 0.05 4.550-02 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 1 1.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 I 9.97E-01 1 1.000+00 0.88 8.76E-01 1 1.000+00 1 1.00E+00 1 1.00E+00 0.08 4.65E-02 7.15E-03 7.15E-03 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.000+00 1 1.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.101-03 2.108-03 1 1.00E+00 1 1.O8+00 1 9.970-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.000+00 1 1.00E+00 1 1.008+00 1.14E-04 1.14E-04 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E+00 0.14 1.44E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.101-03 2.10E-03 I 1.00E÷00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E-00 0.88 8.T76E-01 I 1.00E+00 1 1.00E+00 0 10.00E+00 3.28E-03 3.28E-03 0.05 4.5512-02 1 1.0012+00 0 0.00E+00 I 1.00E+00 O.O0E+00 1 1.00E+00 0.14 1.44E-01 1.01 E-08 I 8.85E-03 0.5 5.00E-011 2.101-03 2.101-03 1 1.00E+00 I 11.00E+.00 1 9.97E-01 1 9.97E-01 1 1.0012+00 0.88 8.76E-01 I 1.00E+00 I 1.00E+00 I 1.00E+00 0.05 4.55E-02 7.15SE-03 7.15E-03 I 1.00E-D00 0 0.00E+00 I 1.00E+00 0.00E+00 I 11.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 I 1.00E+00 I 1.00E+00 1 9.97E-01 I 9.97E-01 1 11.00E+00 0.88 8.7SE-01 1 1.00E+O0
SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 264 TICOOOSW AAitATRANSI ACAA100_0X ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 285 T10000SW AAAATRANSI ACAA1I0_0X ACLOPNOSt2 ACLOPRT687 ACTRAINA ACTRAINB DG1ANOTRUN DGt BNOTRUN NOSBO PCF RCHFD00RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 286 TI0000SW AAAATRANSI ACAA100..OX ACLOPNOS12 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGt BNOTRUN NOSBO PCF RCHFDOORCP SEALLOCA SSLO SWCXXOSUCTI SWTODG AAAA ACHFDRCOFF 287 TI0000SW AAAATRANSI ACAA100 0X ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA 288 TI0000SW AAAATRANSI ACAA1 OOX ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA 289 T10000SW AAAATRANSI ACAA100_OX ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGlANOTRUN DGIBNOTRUN NOSBO PCF RCHFDOORCP SEALLOCA SSLO SWCCIPUMPFR SWTODOG AAAA 290 TI0000SW AAAATRANSI ACAA100_0X TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failurm to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG -OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offiste Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Falure to recover second offsite power circuit after failure of firt Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seat LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 128)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Tdp TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fall to Trp RCPS After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seao LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following ReactorTrip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFOITE POWER MODE 100/S (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Site Power Following Reactor Tdp TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG-DG 1AIS NOT RUNNING AND TIED TO BUSES 14AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient In/Oating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12AAND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure Of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B) 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 0.1 l.00E-01 1 1.00E+00 0.00E-00 1 1.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.121-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.768E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.002E-04 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 1 1.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 I
9.97E-01 1 1.00E+00 0.86 8.76E-01 0.02 1.61E-02 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 I 1.00E+00 0.00E+00 1 1.000E00 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 0.02 1.61E-02 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.000+00 0.1 1.00E-01 1 1.000+00 0.00E+00 1 1.00E000 0.14 1.44E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 6.97E-01 I 9.97E-01 1 1.00E+00 0.88 8.7BE-01 I 1.OlE+00 1 1.0OE000 I 1.00E÷00 1.21E-04 1.21E-04 1 1,00E÷00 0O0.0OE+00 I 1.00E+00 O.00E+00 I 1.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.10E-03 2.10OE-03 I 11.00E+00 I 1.00E+00 I 8.97E-01 I 9.97E-01 I 1.00E+00 0.88 8.76E-01 I 1.00E+00 I 1.00E+00 I 1.00E+00 1.00E-04 1.00E-04 I 1.00E+O0 0 0.00E+00 I 1.00E+00 0.0012+00 I 1.00E+00 0.14 1.44E-01 0.5 5,00E-01 2.10E-03 2.10E-03 I 1.00E+00 I 1.00E+00 I 0.97E-01 I 8.97E-011 I 1.00E+00 0.88 8.76E-01 0.02 1.61E-02 I 11,00E+00 I 1.00E+00 1.21E-04 1.21E-04 1 1,0012+00 0O0.00E+00 I 1.00E÷00 0.00E+00 I 1.00E+00 0.14 1.44E-01
ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGlBNOTRUN NOSBO PCF RCHFDOORCP SEALLOCA SSLO BWCXXOUCTI SWTODG AAAA 291 TI7000SW AAAATRANSI ACAASOL50A ACAAO 50N ACB2FIBS17 ACLOPNOOI2 ACLOPRTSI-1 ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZOOIRCP SEALLOCA SSLO SWTMPUMPIA SWVTMPUMP1C SWTODG AAAA ACHFDRCOFF 292 710000SW AAAATRANSI ACAAOS_50A ACAA50M50N ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN 001 BNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWTMPUMP1A "
SWTMPUMP1C SWTODG AAAA ACHFDRCOFF 293 TI0000SW AAAATRANSI ACAAO590A ACAAS*SON ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DGlANOTRUN DGIBNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 294 TI0000SW AAAATRANSI ACAA50-50A ACAASO-50N ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINS DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWCXXSUCTI SWTlOOG AAAA ACHFDRCOFF 295 TI0000WS AAAATRANSI ACAA50 50A ACAA50_SON ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO
-WCCIPUMPSR SWTODG AAAA ACHFDRCOFF 298 T10000SW CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fall to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiatng Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR u 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A In maintenance SW Pump C in maintenance TAG - 0W Lost to 0G (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second otfsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 125)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offtsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A In maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second olfite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 00/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 125)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following ReactorTrip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG-DG-IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE LIV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
FLAG - OFFOITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 125)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsthe Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 5 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSFTE POWER MODE 501/0 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Seroice Water Pumps To Run TAG - SI Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of irst Total Loss of Service Water 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E÷00 1 1.OOE+00 1 9.97E-01 1 9.97E-01 I 1.00E+00 0.88 8.76E-01 0.02 1.61E-02 1 1.00E+00 1 1.001+00 1.00E-04 1.00E-04 I 1.00E+00 0 0.05E+00 1 1.00E+00 5.00*E00 1 1.00E+00 0.83 8.25E-01 0.02 1.70E-02 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.125-03 2.12E-03 I 1.00E+00 1 1.05E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.005+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0 0.OOE+00 0.1 1.00E-01 1 1.005+00 5.005+00 1 1.00E+00 0.83 8.25E-01 0.02 1.70E-02 1.01 E-08 I
8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0 5.00E+00 0.1 1.005-01 1 1.00E+00 O.00E+00 1 1.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.5 5.00E-01 2.12E-03 2.12E-03 I 1.00E+00 1 1.005+00 I 9.97E-01 1 9.97E-01 1 1.00E+00 0.80 8.76E-01 I 1.00E+00 I 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 I 1.00E+00 0 0.00E+00 0.1 1.00E-011 I 11.00E+00 0.00E+00 1 1.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.5 5.00E-011 2.12E-03 2.12E-03 1 1.00E+00 I 1.00E+00 I 9.97E-01 I 9.97E-011 I 1.0OE+00 0.88 8.78E-01 I 1.00E+00 I 1.00E+00 I 1.00E+00 1.00E-04 1.00E-04 I 11.00E+00 0 0.00E+00 0.1 1.00E-01 I 11.00E+00 0.00E+00 I 11.00E+00 0.83 8.25E-011 0.02 1.70E.-02 0.5 5.00E-011 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E÷00 0.88 8.76E-01 I 1.00E÷00 I 1.00E+00 1 1.(0)E+00 1.21E-04 1.21 E-04 I 1.ODE+00 0 O.00E+00 0.1 1.00E-01 1 1.0012+00 0.00E+00
AAAATRANSI ACAASO..OA ACAAS.
ON ACLOPNOSI2 ACLOPRT787 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 297 TIOOO0SW AAAATRANSI ACAASO_50A ACB2FIBS17 ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGt BNOTRUN DGAAINTAKE NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWAZINTAKE SWTODG AAAA 298 TI0000BW AAAATRANSI ACAAS)0A ACB2FIBS17 ACB2FTBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DGlANOTRUN DGlBNOTRUN NOSBO PCF RCAZ00I RCP SEALLOCA SSLO SWTODG AAAA 299 TI0000SW AAAATRANSI ACAASO_50A ACB2FIBSI7 ACLOPNOSI2 ACLOPRT'751 ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DG1BNOTRUN NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWrMPUMPIA SWTMPUMPIC SWTODG 300 TI0000SW AAAATRANSI ACAAS0 5OA ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIENOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCPUMPSS SWTODG AAAA 301 TI000OSW AAAATRANSI ACAAS0L.50A ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DGIANOTRUN DGI BNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWMMOSWPAS SWTMPUMPIC SWTODG AAAA 302 TIO000SW AAAATRANSI TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 787 TO BUS 12A)
FLAG - OFFSITE POWER MODE S0/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offitse power circuit after failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus IB CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of AN Off-Site Power Following Reactor Trip TAG - Failloe of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Assumption that Lake Temperature Is Cold Enough to Cause Frazl tce and Loss of SW (32/2052 hrs)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE SO/SO ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Site Power Fotlowing Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TAG - SW Lost In DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE S505 ALT (CKT 761 TO BUS 128. CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE SW Pump Ain maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventualty Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E>00 0.83 8.28E-01 0.02 1.70E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.io0E00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.002-01 1 1.00E+00 0.00E+00 1 1.00E+00 0.83 8.25E-01 1.01E-06 1 8.85E-03 1.01E-06 1 8.858-03 0.5 5.00E-01 2.108-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.12 1.23E-01 1 1.00E+00 0.88 8.78E-01 1 1.00>E00 1 1.00E+00 1 1.008+00 0.02 1.88E-02 1 1.00>E00 0 0.00E+00 1 1.00E>00 0.00E+00 1 1.00>E00 0.83 8.25E-01 1.01E-00 1 8.85E-03 1.01E-06 72 7.27E-05 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00>E00 1 1.00>E00 1 9.97E-01 1 9.978-01 1 1.00E+00 0.88 8.78E-01 1 1.008+00 1 1.00E+00 1 1.008+00 1 1.00E+80 0 0.00E+00 1 1.008+00 0.008+00 1 1.00E+00 0.83 8.25E-01 I.018E-f I
8.85E-03 0.5 5.00E-01 2.12E-03 2.128-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E800 I 1.00E+00 I 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 0 1.00E+00 I 1.00E+00 O.O8E+00 1 11.0012+00 0.83 8t.25E-01 1.0111-06 1 8.85E-03 0.5 5.00E-011 2.10DE-03 2.10E-03 1 11.00E+00 1 11.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 11.11412-04 1.14E-04 1 1.00E+00 0 0.00E+00 I 1.00E+00 0.00E+00 I1 1.00E+00 0.83 8.25E-01 1.01E-06 I 8.85E-03 0.5 5.00E-011 2.10DE-03 2.110E-03 I 1.00E+00 1 1.00E+00 I 9.97E-01 I 9.97E-01 I 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.00E+00 I 1.00E+00 3.28E-03 3.28E-03 0.04 3.5SE-02 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 I 1.00E+00
ACAASQOSOA ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWMMOSWPCS SWTMPUMPIA SWTODG AAAA 303 TI0000SW AAAATRANSI ACAAS0-5OA ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWTMPUMP1A SWTMPUMPIC SWTODG AAAA 304 TI0000SW AAAATRANSI ACAAS0_50A ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1 BNOTRUN NOSBO PCF RCHFDOORCP SEALLOCA OSLO SWTMPUMPIA SWTMPUMP1C SWTODG AAA 305 TI0000SW AAAATRANSI ACAA5050A ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINB CVAACHPMPB CVAACHPMPC CVTMCHPMPA DGIBNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWTMPUMPIA SWTMPUMPIC SWTODG 306 T10000SW AAAATRANSI ACAAS0_50A ACB2FIBS18 ACB2FTBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG01BNOTRUN NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWTODG AAA 307 T10000SW AAAATRANSI ACAASO_50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWAASWPICR SWCVC04603 SWTMPUMP1B SWTODG AAAA 308 TI0000SW AAAATRANSI FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - 0G 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO ST CONDITION FOR LOOP Loss of ANl Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Inhtating Event Which Eventualty Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/SB ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Faloure of AC Train A TAG - Failure of AC Train B FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -00 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train B FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump Ain maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFBITE POWER MODE 50/00 ALT (CKT 751 TO BUS 12B. CKr 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Ait Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKr 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND Il FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > I HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSWO1C Is In Operation Service Water Pump PSW01C Discharge Check Valve 4603 Fails To Close On Demand SW Pump B in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE IN AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA) 0.83 8.25E-01 1.010-06 1 8.85E-03 0.5 5.00E-01 2.101-03 2.10E-03 1 1.00E+00 1 1.00E+00 I
9.97E-01 1 8.97E-01 1 1.001>00 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 I 1.00E+00 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.80E+00 1 1.00E+00 0.83 8.25E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 I 1.00E+00 1 1.000+00 1 9.97E-01 1 9.87E-01 1 1.000+00 0.88 8.76E-01 1 1.00E+00 1 1.000+00 I 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.000+00 0 O.00E+00 1 1.00E+00 0.00E+00 1 1.00E+00 0.83 8.25E-01 1.01E-06 I 8.85E-03 0.5 6.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.98E-01 1 1.00E000 0.88 8.76E-01 0.02 1.610-02 1 1.00E+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0 e.O0E+00 1 1.00E+00 0.00E+00 1 1.000>00 0.83 8.25E-01 1.01E-06 1 8.85E-03 0.5 8.000-01 2.10E-03 2.100-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 1 9.97E-01 1 1.00+>00 0.88 8.70E-01 I 1.00E+00 1 1.00E+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 I 1.00E+00 1 1.00E0>0 0.00E+00 1 1.00E+00 0.83 8.25E-01 1.01E-08 1 8.85E-03 1.01E-00 72 7.27E-05 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00>E00 1 1.00E+00 1 1.00E000 0 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E+00 0.83 025E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 8.87E-01 1 9.87E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E000 1 1.00E+00 0.58 5.79E-01 5.84E-04 1
5.84E-04 0.05 4.55E-02 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E+00
ACAASOS0A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZOOIRCP SEALLOCA SSLO SWCCPUMPSS SWTODG AAAA 309 TIOOOOSW AAAATRANSI ACAA50_50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZOOI RCP SEALLOCA SSLO SWMMOSWPBS SWTMPUMP1D SWTODG AAA 310 TIOOOOSW AAAATRANSI ACAASO500A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG18NOTRUN NOSBO PCF RCAZOORCP SEALLOCA SSLO SWMMOSWPDS SWTMPUMPIB SWTODG AAAA 311 TIOOOOSW AAA*TRANSI ACAASO_50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWTMPUMPIB SWTMPUMP1D SWTODG AAAA 312 TI0000SW AAAATRANSI ACAA50.50A ACLOPNOSI2 ACLOPRT751 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 313 TI0000SW AAAATRANSI ACAAS0.50A ACLOPNOSI2 ACLOPRT751 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCAZOOIRCP SEALLOCA
$LO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 314 TI0000SW AAAATRANSI ACAA50_50A FLAG - OFFSITE POWER MODE 50/S0 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Local Fault on 480 VAC Bus IS CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LbOA)
FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP B TO START SW Pump D in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AD Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP D TO START SW Pump B In maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Alt Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trip Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit alter failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsito Circuit 751 Following Reactor Trip Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOOAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit alter failure of first Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A) 0.83 8.25E-01 1.01E-06 1 8.8SE-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E-00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.14E-04 1.14E-04 1 1.002+00 0 0.00E+000 1 1.001+00 0.00>E00 1 1.SOE+00 0.83 8.25E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.OOE+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.008+00 I 1.00E+00 3.28E-03 3.28E-83 7.15E-03 7.15E-03 1 1.00E+00 8 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E800 0.83 8.25E-01 1.01E-06 I 8MB5E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 t.00E+00 1 1.000+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.8OE+00 1 1.00E+00 1 1.00E+00 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.00E+00 0 0.00E+00 I 1.00E+00 0.00E+00 1 1.00E+00 0.83 8.25E-01 1.01E-00 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00>E00 1 1.008+00 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 00.00E800 1 1.008+00 0.001+00 1 1.00E+00 0.83 8.25E-01 0.8 5.00E-01 2.12E-03 2.12E-03 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 t.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00D0.00E+00 1 1.008+00 0.83 8.25E-01 0.8 5.00E-01 2.12E-03 2.12E-03 2.12E-03 2.12E-03 I 1.00E+00 I 1.00E+00 I 9.97E-01 I
9.97E-01 1 1.00E+00 0.88 8.76E-00 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.0012-04 1 1.00E+00 0 0.00+>00 0.1 1.00E-01 1 1.00E+00 0.008+00 1 1.00E+00 0.83 8.25E-01
ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB CVTMCHPMPA DGlANOTRUN DGIBNOTRUN DGDGFOO01B NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCCIPUMPSR AAAA 315 TISOOOSW AAAATRANSI ACAASOSEA ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB CVTMCHPMPA DG1ANOTRUN DGIBNOTRUN DGDGFOOIB NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCXXSUCTI AMAA 316 TI0000SW AAAATRANSI ACAAM0L50A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB CVTMCHPMPA DG1ANOTRUN DG18NOTRUN DGTMOOOOIB NOSBO PCF RCAZSO1RCP SEALLOCA SSLO SWCCIPUMPSR AAAA 317 TI0000SW AAAATRANSI ACAA50_50A ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINS DGIANOTRUN DGIBNOTRUN DGCCOORUN NOSBO PCF RCAZOO1 RCP SEALLOCA SSLO SWCCIPUMPSR AAA 318 TI0000SW AAAATRANSI ACAA5OJS0A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN DGCCO0ORUN NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWC)OXSUCTI AAAA 319 TI0000SW AAAATRANSI ACAASOJOA ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN DGDGFOO01A DGDGF0001B NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCCIPUMPSR AAAA 320 TI0000SW AAAATRANSI ACAASO_5OA ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Sile Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATOR KDG01 B FAILS TO RUN TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOOAS TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/S0 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Tdp TAG - Failure of AC Train A TAG-Failure of AC Train B TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATOR KDG0I B FAILS TO RUN TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE SE/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Ali Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATOR KDGOIB UNAVAILABLE DUE TO TESTING OR MAINTENANCE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Iniflating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Iniating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditiens (Seal LOCA)
FLAG - OFFSITE POWER MODE SE50/ ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Top TAG - Failure of AC Train A TAG - Falluro of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATOR KDGOA FAILS TO RUN DIESEL GENERATOR KDGOIB FAILS TO RUN TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AR Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Fallur of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR 0.5 5.00E-01 2.10E-03 2.10E-03 I 1.00E.00 1 1.00E+00 0.08 8.2112-02 1 9.97E-01 I 9.97E-01 1.41E-03 24 3.38E-02 I 1.00E+00 0.88 8.76E-01 1 1.002+00 1 1.002+00 1 1.00E+00 1.21E-04 1.21E-04 0 0.00E+00 1 1.002+00 0.00E+00 1 1.00E+00 0.83 8.28E-01 0.5 5.00E-01 2.10E-03 2.1OE-03 1 1.00E+00 1 1.00E+00 0.08 8.21E-02 1 9.97E-01 1 9.97E-01 1.41E-03 24 3.38E-02 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.002+00 1.00E-04 1.00E-04 0 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E-00 0.83 8.25E-01 0.5 8.00E-01 2.10E-03 2.10E-03 1 1.00E200 1 1.00E+00 0.08 8.21E-02 1 9.97E-01 1 9.97E-01 0.01 1.49E-02 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 0 O.00E+00 1 1.00E+00 0.00E+00 1 1.00E+00 0.83 8.25E-01 0.5 6.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E200 I 9.97E-01 I 9.97E-01 1.36E-03 1.36E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E200 1.21E-04 1.21E-04 0 0.00E+00 1 1.00E+00 0.002+00 1 1.00E+00 0.83 8.25E-01 0.8 5.00E-01 2.10E-03 2.10E-03 1 1.00E200 1 1.00E200 1 9.97E-01 1 9.97E-01 1.36E-03 1.36E-03 1 1.002+00 0.88 8.76E-01 1 1.002+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.0012-04 0 O.00E+00 I 1.00E+00 0.0012÷00 1 1.00E200 0.83 8.25E-01 0.5 5.00E-01 2.102-03 2.10E-03 1 1.002>00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1.41E-03 24 3.38E-02 1.41E-03 24 3.38E-02 1 1.00E+00 0.88 8.76E-01 1 11.00E+00 I 1.O0E+DO 1 1.00E+O0 1.21 E-04 1.21E-04 0 0.00E+00 1 1.00E+00 0.00ED00 1 1.00E÷00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.1012-03 I 1.00E+O0 I 1.00E÷00 I 9.97E-01 I 9.97E-01 I 1.00E+00 0.83 8.76E-01
RCAZ051RCP SEALLOCA SSLO SWAASWPIBNR SWAASWP1DR SWMMSWPDRI SWIMPUMPIA SWTMPUMP1B SWTMPUMP1C SWTODG AAAA 321 TIOOOOSW AAAATRANSI ACAASOOS0A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DGIANOTRUN DGI BNOTRUN NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWMSVPIBR SWAASWPIDR SWMMSWPBRI SWMMSWPDRI SWTMPUMPIA SWTMPUMPiC SWTODG AAAA 322 TI000OSW AAAATRANSI ACAASOf50A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG18NOTRUN NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA 323 TIOOOOSW AAAATRANSI ACAA5O 50A ACLOPNOSI2 ACLOPRTALL.
ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZOOIRCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA 324 TIOOOOSW AAAATRANSI ACAA50SO0A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF RCHFDOORCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA 325 TI0000SW AAAATRANSI ACAASO 5OA ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF RCHFDOORCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA 326 TI000OSW AAAATRANSI ACAASO 50A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DG1ARUN DGISNOTRUN DGAZRUNDGA NOSBO PCF RCAZ001RCP NO RCP SEAL COOLING FOR ' 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSW0IB Is Not In Operation FLAG - Service Water Pump PSW01D Is In Operation FAILURES OF SW PUMP 0 TO RUN SW Pump A in maintenance SW Pump B in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Servoce Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seat LOCA)
FLAG - OFFSITE POWER MODE 50150 ALT (CK' 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of An Off-Site Power Following Reactor Trip TAG - Fatlure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND lB FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR ' 1 HOUR TAG - TRANSIENT INDUCED SEAL LOGAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSWOIB Is In Operation FLAG - Service Water Pump PSW0ID Is In Operation FAILURES OF SW PUMP B TO RUN FAILURES OF SW PUMP D TO RUN SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Resulis in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of At Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR ' 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Faolurn of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR ' 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Condotions (Seal LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-See Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Trip RCPs After Loss of Support Systemn TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventuaey Results in SI Conditions (Seat LOCA)
FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of An Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Faelure ofAC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Falt to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of An Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR ' 1 HOUR 1 1.00S+00 I 1.00s+00 I I.00E+n0 0.42 4.21 E-01 0.58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 I 1.00E+00 0 0.00E+00 1 1.0E+01 0.0OOE+00 I 1.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10f-o03 2.10E-03 1 1.00E.00 I 1.O0E+00 1 9.87E-01 I 9.97E-01 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.58 5.79E-01 0.58 5.79E-01 0.02 2.47E-02 0.02 2.47E-02 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E200 0.83 8.25E-01 0.5 5.00E-01 2.10f-03 2.10f-03 1 1.85E800 1 1.00E+00 I
9.97E-01 1 9.97E-01 1 lOOfE+00 0.88 8.76E-01 1 1.00E+80 1 1.OOE+00 I 1.00E+00 1.21E-04 1.21E-04 1 1.85E+00 0 0.05E+00 1 1.85E+00 0.00E+00 1 1.008E+8 0.83 8.25E-01 0.5 5.00E-01 2.10f-03 2.10E-03 I 1.00E-00 I 1.00E+00 1 9.97E-01 1 9.97E-01 I 1.O0E+00 0.88 8.76E-01 1 1.00E+00 1 1.t052+85 1 1.00E+00 1.00E-04 1.00E-04 1 1.85E+00 0 0.80E+00 1 1.00E+00 0.85E+00 1 1.85E+00 0.83 8.25E-01 0.5 5.008f-01 2.10E-03 2.10E-03 I 1.05E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 I 1.00E+00 0.88 8.78E-01 0.02 1.61E-02 1 1.00E+00 0 1.00E+00 1.21E-04 1.21E-04 1 1.85E+00 1 0.008+00 1 1.00E700 0.01E+00 1 1.008+00 0.83 8.25E-01 0.5 1.81E-01 2.10E-03 2.1.0E-03 1 1.00E+00 1 1.00E-00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.02 1.61E-02 1 1.00E÷00 1 1.00E+00 1.00E-04 1.0012.04 I 1.00E÷00 0 0.00E+00 1 1.00E+00 0.D0E+00 1 1.0012+00 0.83 8.25E-01 0.5 5.0012-01 2.10OE-03 2.10E-03 1 1.00E+00 I 1.00E+00 0.03 3.00E-02 I
9.97E-01 0.1 1.00E-01 I 11.00E+00 0.88 8.76E-01 1 11.0012+00
SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA 327 TIOOOSSW AAAATRANSI ACAAS0SOA ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIARUN DGIBNOTRUN DGAZRUNDGA NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA 328 TI0000SW AAAATRANSt ACAA5050N ACB2FIBSI7 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZO0IRCP SEALLOCA SSLO SWTMPUMP1A SWTMPUMPIC SWTODG AAAA 329 T10000SW AAAATRANSI ACAASO_50N ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB OGIANOTRUN DG1 BNOTRUN NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR SWTODG AAAA 330 TI0000SW AAAATRANSI ACAA50_50N ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWCXXSUCTI SWTODG AAAA 331 T10000SW AAAATRANSI ACB2FIBSI7 ACB2FIBS18 ACTRAINA ACTRAINB CVMMRCPIFP DGAAINTAKE NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWAZINTAKE AAAA 332 TI000OSW AAAATRANSI ACB2FIBS17 ACB2FTBS18 ACTRAINA ACTRAINB CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZOO1RCP SEALLOCA SSLO AAAA 333 T10000SW AAAATRANSI ACB2FIBS17 ACB2FTBS18 ACTRAINA ACTRAINB CVMMRCPIFP TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 TAG - SMALL SMALL LOCA SEQUENCE I 1.00E+00 Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.211-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS S 0.O0E+00 Total Loss of Service Water 1 1.00E+00 O.00E+00 TAG - Transient Initiating Event Which ESentually Results in SI Conditions (Seal LOCA)
I 1.00E+00 FLAG - OFFSITE POWER MODE 5/50 ALT (CK"T 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of At Off-Site Power Following Reactor Trip 2.101-03 2.10E-03 TAG - Failure of AC Train A I 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 0.03 3.00E-02 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.00E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 NO RCP SEAL COOLING FOR> 1 HOUR 1 1.00E+00 TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TAG - SW Lost to DG (cooling) 1 1.00+E00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E÷00 Total Loss of Service Water 1 1.00E+00 0.00E+00 TAG - Transient Initiating Event Which Evenotualy Results In SI Conditions (Seal LOCA) 1 1.008+00 FLAG - OFFSITE POWER MODE 5/SO NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 128) 0.02 1.70E-02 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.85E-03 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.008-01 Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - 00 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG -0 08 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.80 8.76E-01 NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 TAG - TRANSIENT INDUCED SEAL LOCAS 1 1.008+00 TAG - SMALL SMALL LOCA SEQUENCE I 1.00+O00 SW Pump A in maintenance 0.03 3.13E-02 SW Pump C in maintenance 0.04 3.56E-02 TAG - SW Lost to DG (cooling) 1 1.00E+00 FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 O.00E+00 Total Loss of Service Water 1 1.00E+00 0.0OE+00 TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.768E-01 NO RCP SEAL COOLING FOR > I HOUR 1 1.00E+00 TAG - TRANSIENT INDUCED SEAL LOAs 1 1.00+E00 TAG - SMALL SMALL LOCA SEQUENCE 1 1.0OE+00 Common Cause Falure Of Service Water Pumps To Run 1.211-04 1.21E-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water 1 1 008+00 0.00E+00 TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B) 0.02 1.70E-02 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of AS Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG-Falure of AC Train B 1 1.008+00 FLAG -DG 1A IS NOT RUNNING AND TIEDTO BUSES 14AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT I 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 NO RCP SEAL COOLING FOR + 1 HOUR 1 1.00E+00 TAG -TRANSIENT INDUCED SEAL LOCAs 1 1.008+00 TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TAG - SW Lost to DG (cooling) 1 1.00+E00 FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.008E00 Total Loss of Seruice Water 1 1.00E+00 0.00E+00 TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA) 1 1.00E+00 Local Fault on 480 VAC Bus 17 1.01E-06 1 0.58E-03 Local Fault o0 480 VAC Bus 18 1.01E-06 1 8.858-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.008+00 NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03 FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED 0.12 1.23E-01 TAG - NO STATION BLACKOUT 1 1.008+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 NO RCP SEAL COOLING FOR > 1 HOUR 1 1.00E+00 TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 Assumplion that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (32/2052 his) 0.02 1.66E-02 FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water 1 1.00E+00 O.00E+00 TAG - Transient Initiating Event Which Eveotualy Results in SI Conditions (Seat LOCA) 1 1.00E+00 Local Fault on 480 VAC Bus 17 1.01E-06 1 8.851-03 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-0O TAG - Failur of AC Train A 1 1.00E+00 TAG - Faulure of AC Train B 1 1.00E+00 FLAG - CHARGING PUMP A RUNNING 0.58 5.77E-01 FLAG - CHARGING PUMP B RUNNING 0.58 5.77E-01 FLAG - CHARGING PUMP C RUNNING 0.58 5.77E-01 OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP 1.00E-03 1.00E-03 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 NO RCP SEAL COOLING FOR > 1 HOUR 1 1.008+00 TAG - TRANSIENT INDUCED SEAL LOCAs 1 1.00E+00 TAG - SMALL SMALL LOCA SEQUENCE 1 1.00E+00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water 1 1.008+00 O.008E00 TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 1 1.00E+00 Local Fault on 480 VAC Bus 17 1.018-06 1 6.85E-03 Local Fault on 480 VAC Bus 18 1.01 E-06 72 7.27E-05 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS) 1.50E-03 1.50E-03
NOSBO PCF RCAZOO1RCP SEALLOCA SSLO AAAA 334 TI000OSW AAAATRANSI AC82FIBS17 ACTRAINB CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCCPUMPSS 335 TI0000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWMMOSWPAS SWTMPUMPIC 338 TI0000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVAACHPMPA CVAACHPMPB
.CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWMMOSWPCS SWTMPUMPIA 337 TI0000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWrMPUMP1A SWTMPUMPIC 338 T10000SW AAAATRANSI ACB2FIBS17 ACTRAINS CVAACHPMPA CVAACHPMPB CVAACHPMPC CVTMCHPMPA CVTMCHPMPB CVTMCHPMPC NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWTMPUMP1A SWTMPUMP1C 339 TI0000SW AAMATRANSI ACB2FIBS17 ACTRAINB CVCCMPFABC NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWTMPUMPIA SWTiMPUMPIC 340 T10000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPAFP NOSBO POF RCAZ001RCP SEALLOCA SSLO SWTMPUMP1A SWTMPUMPIC 341 TIOO0SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPALP NOSBO PCF RCAZ001RCP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In St Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > I HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Vlater Pumps To Start Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A in maintenance Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Seivice Waler TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B COMMON CAUSE FAILURE OF THE CHARGING PUMPS TO RUN TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C In maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in St Conditions (Seat LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR
- 1 HOUR 1 1.OcE+00 0.88 8.78E-01 1 1.00E+00 I 1.OOE+00 1 1.00E+00 0 0.00E+00 1 I.00Ev00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.00E-03 1.00E-03 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 I 1.00E+00 1 1.00E+00 1.14E-04 1.14E-04 I 1.00E+00 0.00E+00 1 1.00E+00 1.01E-08 1 8.05E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-O1 0.58 5.77E-01 1.00E-03 1.001-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 I 1.00E+O0 1 1.00E+00 3-28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 0.00E200 1 1.00E+00 1.01 E-06 1 8.85E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.000-03 1.00E-03 1 1.00E+O0 0.88 8.76E-01 1 1.000+00 1 1.00E+00 1 1.00E+00 3.28E-03 3.28E-03 0.03 3.13E-02 I 1.00E+00 0.000+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.00E-03 1.000-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.000+00 1 1.OOE-00 0.0lE 3 3.13E5-03 0.04 3.56E-02 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.805-03 1 1.00E+00 0.58 5.77E-01 D.58 5.77E-01 0.58 5.77E-011 D.08 8.21E-02 0.09 8-6OE-02 1.04 3.85E-02 1 1.00E+00 0.88 8.76E-011 1 1.00E+00 1 11.00E+00 1 11.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0.00E+00 1 1.000+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.36E-05 1.36E-05 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.(X)E+00 0.03 3.113E-02 0.04 3.56E-02 1 1,00E+00 0.00E+00 1 1.00E+00 1.01E-06 I 8.85E-03 I 1.00E+00 4.88E-05 4.88E-05 I 11.00E+00 0.88 8.76E-01 I 1.00E+00 1 11.0012+00 I 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.0012+00 0.00E+O0 I 1.00E+00 1.01E-08 I 8.85E-03 I 1.00E+00 5.34E-05 5.34E-06 I 11.00E+00 0,88 8.76E-01 I 11.00E+00
SEALLOCA SSLO S'WTMPUMPIA SWTMPUMPIC 342 TISOOOSW AAAATRANSI ACB2FIES17 ACTRAINB CVMMRCPBFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWTMPUMP1A SWTMPUMP1C 343 T10000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPBLP NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWTMPUMPIA SWTMPUMP1C 344 TI0000SW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCAZ00tRCP SEALLOCA SSLO SWTMPUMP1A SWTMPUMP1C 345 TI0COOSW AAAATRANSI ACB2FIBS17 ACTRAINB CVMMRCPIFP NOSBO PCF RCHFDO0RCP SEALLOCA SSLO SWTMPUMP1A SWTFMPUMPIC 346 TIO0OOSW AAAATRANSI ACB2FIBS17 ACTRAINB CVPPJCVCOM NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWTMPUMP1A SWTMPUMPIC 347 TIOGO0SW AAAATRANSI ACB2FIBS18 ACB2FTBS17 ACTRAINA ACTRAINB CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZO01RCP SEALLOCA SSLO AAAA 348 TI0000SW AAAATRANSI ACB2FIBSI8 ACB2FTBS17 ACTRAINA ACTRAINE CVMMRCPIFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO AAAA 349 TI0000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCPUMPSS 350 TI0000SW AAAATRANSI ACB2FIBSS8 ACTRAINA CVAACHPMPA CVAACHPMPB CVAACHIPMPC TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR - 1 HOUR TAG -TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventualy Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B SEAL LEAKOFF PATH FROM RCP B OBSTRUCTED TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOOAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Tdp RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump Ain maintenance SWN Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Common CVCS Piping Rupture TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR ' 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train A TAG - Failure of AC Train B NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOOA)
Local Fault o0 480 VAC Bus 18 TAG - Failure of AC Train A FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR ' 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOOA SEQUENCE Common Cause Failure Of Service Water Pumps To Start Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING 1 1.00E+00 I 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 O.001E00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 4.88E-05 4.88E-05 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.00E-00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 5.34E-05 5.34E-05 1 1.00E+00 0.88 8.76E-01 1 1,00E+00 1 1.00E+00 1 1.00E+80 0.03 3.13E-02 0.04 3.56E-02 1 1.008+00 0.00E+00 1 1.008+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.008+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0,008E00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 0.02 1.61E-02 1 1.008+00 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-08 1 8.851-03 1 1.00E+00 1.98E-00 24 4.75E-05 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.00E+00 1 1.008+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1.01E-06 72 7.27E-05 1 1.00E+00 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.00E-03 1.00E-03 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1.01E-08 72 7.27E-05 1 1.00E+00 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0 0.00E+00 I 1.00E+00 0.00E+00 1 1.00E+00 1.01E-00 1 8.85E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.008-03 1.008-03 1 1.00E+00 0.88 8.76E-01 1 1.008+00 1 1.00E+00 1 1.008+00 1.14E-04 1.14E-04 1 1.008+00 0.00E+00 1 1.00E+00 1.011E-06 1 8.80E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01
CVHFDPMPST NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWMM0SWPDS SWTMPUMPIB 351 TISOOOOW AAAATRANSI ACB2FIBS18 ACTRAINA CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWTMPUMP1 B SWTMPUMP1 D 352 T10000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVAACHPMPA CVAACHPMPB CVAACHPMPC CVTMCHPMPA CVTMCHPMPB CVTMCHPMPC NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWTMPUMP1B SWTMPUMP1D 353 T10000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPAFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWTMPUMP1B SWTMPUMPID 354 TIOOOSW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPALP NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWTMPUMP1B SWTMPUMPID 355 T100OSW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPBFP NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWTMPUMPIB SWTMPUMPID 356 710000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPBLP NOSBO PCF RCAZOOIRCP SEALLOCA SSLO SWTMPUMPIB SWTMPUMP1D 357 T10000SW AAAATRANSI ACB2FIBS18 ACTRAINA CVMMRCPIFP NOSBO PCF RCAZOIRCP SEALLOCA SSLO SWTMPUMP1B SWTMPUMP1D 358 TIO7O1SW AAAATRANSI ACB2FIBS18 ACTRAINA CVPPJCVCOM NOSBO PCF RCAZO0IRCP SEALLOCA SSLO SWTMPUMPIB SWTMPUMPiD 359 T10000SW AAAATRANSI OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FAILURES OF SW PUMP D TO START SW Pump B in maintenance Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Faiure of AC Train A FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Servoce Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW FROM SEAL INJECTION FILTER A TO RCP A SEAL TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL LEAKOFF PATH FROM RCP A TO COMMON HEADER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conddlons (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW PATH TO RCP B SEAL FROM SEAL INJECTION FILTER TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A SEAL LEAKOFF PATH FROM RCP B OBSTRUCTED TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventuatly Results in SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Common CVCS Piping Rupture TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditiens (Seal LOCA) 1.0OE-03 1.00E-03 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 I 1.00E+00 3.28E-03 3.28E-03 0.05 4.55E-02 I 1.008+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.00E-03 1.00E-03 I 1.O0E+00 0.88 8.76E-01 1 1.OlE+00 I 1.00E+00 1 1.00E+00 0.05 4.5SE-02 7.15E-03 7.15E-03 1 1.00E+00 O.00E+00 1 1.00E+00 1.01E-05 1 8.85E-03 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 0.09 8.60E-02 0.04 3.85E-02 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 4.88E-05 4.88E-05 1 1.008+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 0.00E+00 1 1.00E800 1.01E-06 1 8.85E-03 1 1.00E÷00 5.34E-05 5.34E-05 1 1.0OE+00 0.88 8.76E-01 I 1.00E+00 I 1.00E+00 I 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.008+00 0.0OE+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 4.88E-O05 4.88E-O5 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 5.34E-O5 5.34E-05 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.001+00 1 1.00+E00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 0.001+00 1 1.00E+00 1.01E-06 I 8.85E-03 1 1.00E+00 1.50E-03 1.501-03 1 1.00E+00 0.88 8.78E-01 1 1.008>00 1 1.00E+00 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 0.00E+00 1 1.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 1.98E-06 24 4.75E-05 1 1.008+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 0.00E+00 1 1.00E+00
CVAACHPMPA CVAACHPMPB CVAACHPMPC CVCCMPAABC NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWCCIPUMPSR 360 TIOOOOSW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVCCMPAABC NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWCXXSUCTI 361 TI0000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCAZO01RCP SEALLOCA SSLO SWCCIPUMPSR 362 TI0000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSSO PCF RCAZOO1RCP SEALLOCA SSLO SWCXXSUCTI 363 T10000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCHFD00RCP SEALLOIdA SSLO SWCCIPUMPSR 364 TI0000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVHFDPMPST NOSBO PCF RCHFD0ORCP SEALLOCA SSLO SWCXXSUCTI 365 TI0000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVMMPCH1CA CVTMCHPMPA CVTMCHPMPB NOSBO PCF RCAZ0O1RCP SEALLOCA SSLO SWCCIPUMPSR 366 T10000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVMMPCH1CA CVTMCHPMPA CVTMCHPMPB NOSBO PCF RCAZODIRCP SEALLOCA SSLO SWCXXSUCTI 367 T10000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVMMPCH1CF CVTMCHPMPA CVTMCHPMPB NOSBO PCF RCAZ001RCP SEALLOCA SSLO SW1CCIPUMPSR 368 TIOOOOSW AAAATRANSI FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING COMMON CAUSE FAILURE OF CHARGING PUMPS TO START TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING COMMON CAUSE FAILURE OF CHARGING PUMPS TO START TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Servine Water Pumps To Run Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP S RUNNING FLAG-CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operators Fail to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Waler TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING OPERATORS FAIL TO MANUALLY LOAD CHARGING PUMP TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Operatom Fail to Trip RCPs After Loss of Support Systems TAG - TRANSIENT INDUCED SEAL LOCAS TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING CHARGING PUMP PCH01C FAILS TO START TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING CHARGING PUMP PCH01C FAILS TO START TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP S UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP S RUNNING FLAG - CHARGING PUMP C RUNNING CHARGING PUMP PCHOIC FAILS TO RUN TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Losw of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA) 0.58 S.77E-01 0.58 5.77E-01 0.58 5.77E-01 5.78E-05 5.78E-05 1 1.001+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0.00E+00 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 5.78E-OS 5.78E-05 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.001+00 1 1.00E+00 1.00E-04 1.00E-04 I 1.00E+00 0.00E+00 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-C1 0.58 5.77E-01 1.00E-03 1.00E-03 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0.00E+00 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.00E-03 1.00E-C3 1 1.00E+00 0.88 8.76E-C1 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 I 1.00E+00 0.OOE+00 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-C1 1.00E-03 1.00E-03 1 1.00E+00 0.88 8.76E-01 0.02 1.61E-02 1 1.00E+00 1 1.00E+00 1.21E-04 1.21E-04 1 1.005+00 0.00E+00 1 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.00E-03 1.00E-03 1 1.00E+00 0.88 8.76E-01 0.02 1.81E-02 1 1.00E+00 1 1.00E500 1.00E-04 1.00E-04 I 1.00E+00 0.00E+00 1 1.00E+00 0.58 5.77E-C1 0.58 5.77E-C1 0.58 5.77E-01 1.04E-03 1.04E-03 0.08 8.21E-02 0.09 8.80E-02 1 1.001200 0.88 8.78E-01 1 1.00E+00 1 1.00E+00 1 1.005+00 1.21E-04 1.21E-04 1 1.00E+00 0.00E+00 I 1.00E+00 0.58 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 1.04E5-3 1.04E-03 0.08 8.21E-02 0.09 8.60E-02 1 1.001+00 0.88 8.76E-01 1 1.00E+00 1 1.005200 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0.00E+00 1 1.001+00 0.58 5.77E-C1 0.58 5.77E-01 0.58 5.77E-01 1.31E-03 1.31E-03 0.08 8.21E-02 0.09 8.60E-02 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E-00 1 1.00E-00 1.21E-04 1.21E-04 1 1.00E+00 0.OOE+00 1 1.00E+00
CVAACHPMPA CVAACHPMPB CVAACHPMPC CVMMPCH1CF CVTMCHPMPA CVTMCHPMPB NOSBO PCF RCAZOOIRCP SEALLOCA SSLO SWCxXSUCTI 389 TI0000SW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVTMCHPMPA CVTMCHPMPB CVTMCHPMPC NOSSO PCF RCAZOOIRCP SEALLOCA SSLO SWCCIPUMPSR 370 TIOOOOSW AAAATRANSI CVAACHPMPA CVAACHPMPB CVAACHPMPC CVTMCHPMPA CVTMCHPMPB CVTMCHPMPC NOSSO PCF RCAZOOIRCP SEALLOCA SSLO SWCXXSUCTI 371 T10000SW AAAATRANSI CVMMRCPIFP NOSBO PCF RCAZ001 RCP SEALLOCA SSLO SWAASWP1 BNR SWAASWPIDR SWMMSWPDRI SWTMPUMPIA SWTMPUMPIB SWTMPUMPIC 372 110000SW AAAATRANSI CVMMRCPIFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWAASWP1BNR SWPPJIHDRB SWIMPUMP1A SWTMPUMP1B SWIMPUMPIC 373 TI0000SW AAAATRANSI CVMMRCPIFP NOSBO PCF RCAZO01 RCP SEALLOCA SSLO SWAASWP1ER SWAASWP1 DR SWMMSWPBRI SWMMSWPDRI SWTMPUMPIA SWTMPUMP1C 374 TI0000SW AAAATRANSI CVMMRCPIFP NOSBO PCF RCAZ001RCP SEALLOCA SSLO SWAASWPIBR SWMMSWPBRI SWPPJIHDRB SWTMPUMPIA SWTMPUMPIC 375 TIO0OOSW AAAATRANSI CVMMRCPIFP NOSBO PCF RCAZOO1RCP SEALLOCA SSLO SWAASWPIDR SWMMSWPDRI SWPPJIHDRA SWTMPUMPIA SWTMPUMPIC 376 TIOO0SW ACAA0O100X ACAZDLOSPI ACLOPNOSI2 A*LOPRT7$1 ACTRAINA ACTRAINB FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP S RUNNING FLAG - CHARGING PUMP C RUNNING CHARGING PUMP PCH01C FAILS TO RUN TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP S UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE Common Cause Failure Of Service Water Pumps To Run Total Loss of Servce Water TAG - Transient Initialing Event Which Eventually Results in tS Conditions (Seal LOCA)
FLAG - CHARGING PUMP A RUNNING FLAG - CHARGING PUMP B RUNNING FLAG - CHARGING PUMP C RUNNING TEST OR MAINTENANCE RENDERS CHARGING PUMP A UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP B UNAVAILABLE TEST OR MAINTENANCE RENDERS CHARGING PUMP C UNAVAILABLE TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results In SI Conditions (Seal LOCA)
NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSWO1B Is Not In Operation FLAG - Service Water Pump PSWOID Is In Operation FAILURES OF SW PUMP D TO RUN SW Pump A in maintenance SW Pump B in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSW01B Is Not In Operation SERVICE WATER HEADER "5" PIPING RUPTURE SW Pump A in maintenance SW Pump B in maintenance SW Pump C In maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR> 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSWO1 B Is In Operation FLAG - Service Water Pump PSW01D Is In Operation FAILURES OF SW PUMP B TO RUN FAILURES OF SW PUMP D TO RUN SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initialing Event Which Eventually Results in SI Conditions (Seal LOCA)
NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSW0IB Is In Operation FAILURES OF SW PUMP B TO RUN SERVICE WATER HEADER "B" PIPING RUPTURE SW Pump A in maintenance SW Pump C in maintenance Total Loss of Service Water TAG - Transient Initiating Event Which Eventually Results in SI Conditions (Seal LOCA)
NO FLOW THROUGH SEAL INJECTION FILTER A (SERVES BOTH TRAINS)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR NO RCP SEAL COOLING FOR > 1 HOUR TAG - TRANSIENT INDUCED SEAL LOCAs TAG - SMALL SMALL LOCA SEQUENCE FLAG - Service Water Pump PSW1D D Is In Operation FAILURES OF SW PUMP D TO RUN SERVICE WATER HEADER "A" PIPING RUPTURE SW Pump A In maintenance SW Pump C in maintenance Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 125)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsile Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B 0.58 5.77E-01 0.58 577E-01 0.58 5.77E-01 1.31E-03 1.31E-03 0.08 8.21E-02 0.09 8.60E-02 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0.00E+00 1 1.00E+00 0.58 5.77E-01 0.58 6.77E-01 0.58 5.77E-01 0.08 8.21 E-02 0.09 8.60E-02 0.04 3.85E-02 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 I 1.00E+00 1.21E-04 1.21E-04 I 1.00E+00 0.00E+00 I 1.00E+00 0.08 5.77E-01 0.58 5.77E-01 0.58 5.77E-01 0.08 8.21E-02 0.08 8.60E-02 0.04 3.85E-02 I 1.00E-00 0.88 8.78E-01 1 1.00E+00 I 1.00E+00 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0.00E00 1 1.00E+00 1.50E-03 1.50E-03 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.42 4.21E-01 0.58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.00 4.55E-02 0.04 3.56E-02 1 1.00E+00 0.00E+00 I 1.00E+00 1.50E-03 t.50E-03 1 I.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+O0 1 1.00E+00 0.42 4.21E-01 5.53E-07 1 4.84E-03 0.03 3.13E-02 0.03 4.55E-02 0.04 3.58E-02 1 1.00E+00 0.00E+00 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.00E+00 1 1.00E+00 0.58 5.79E-01 0.58 5.79E-01 0.02 2.47E-02 0.02 2.47E-02 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0.002+00 1 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.58 5.79E-01 0.02 2.478-02 5.53E-07 1 4.84E-03 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0.00E+00 I 1.00E+00 1.50E-03 1.50E-03 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 1 1.0012+00 I 1.00E+00 0.58 5.79E-01 0.02 2.47E-02 5.53E-07 1 4M84E-03 0.03 3.13E-02 0.04 3.56E-02 I 1.00E+00 0.00E+00 0.02 1.5012-02 0.38 3.81E-01 0.5 5.00E-01 2.12E-03 2.112E-03 1 1.0012+00 1 1.00E÷00
DGIANOTRUN DGI BNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTOOG AAAA ACHFORCOFF 377 TI1O0OSW ACAAOIOOX ACAZDLOSP1 ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINS DGIANOTRUN DGIBNOTRUN NOSBO PCF
$60 SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 378 TI0000SW ACAA0.100X ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA 379 TIOOO0SW ACAAO_100X ACAZDLOSP1 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA 380 T10000SW ACAAO..100X ACB2FIBS17 ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DG1ANOTRUN DG1 BNOTRUN NOSBO PCF SWTMPUMPIA SWTMPUMPIC SWTODG TRANSX AAAA ACHFDRCOFF 381 T10000SW ACAA0_b1OX ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1 BNOTRUN NOSBO PCF SWTMPUMP1A SWTMPUMPIC SWTODG TRANSX AAAA 382 TI0000SW ACAAO.100X ACLOPNOS12 ACLOPRT751 ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DGIBNOTRUN NOSBO PCF BED SWCCIPUMPSR SWTODG WAA ACHFDRCOFF 383 TI000OSW ACAA0_100OX ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB AFAZFAIL)OC DG1ANOTRUN DG1BNOTRUN NOSBO FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 1S AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Case Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12AAND 128)
Failure to Restore Offsite Power Wilthin I Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG;B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to D1 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit afterfa/lure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128)
Failure to Restore Offskie Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - D0 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 0
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to D0 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSrTE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-Site Power Folklwing Reactor Trip TAG - Failure of AC Train A TAG-Failure of AC Train B FLAG - D 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -0O B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to D0 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offs/te Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsita power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
Local Faust on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to D0 (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offlste Circuit 751 Following ReactorTop TAG - Failure ofAC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to D0 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offs/Ie power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 138 AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trip TAG - Faiure of AC Train A TAG - Faiurm of AC Train B Non-Elec Fa/lure of al MDAFW pumps (independeont of AF300)
FLAG - D 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT 1 9.97E-01 1 9.97E-01 1 1.00E.00 0.88 8.76E-01 1 1.00E+00 1.211-04 1.21E-04 1 1.00E+00 0 0.OOE+00 0.1 1.00S-01 1 1.00OE+00 0.00E00 0.02 1.50E-02 0.38 3.81E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E200 0 0.000E00 0.1 1.00E-01 1 1.00E-00 0.00E+00 0.02 1.50E-02 0.38 3.81E-01 0.5 8.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.000+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 O 0.00E+00 1 1.00E+00 0.000000 0.02 1.50E-02 0.38 3.81E-01 0.5 5.000-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 8.97E-01 1 1.00E+00 0.88 8.761-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.000+00 0.02 1.50E-02 1.011E-06 1 8-85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.000+00 1 1.00E+00 1 9.87E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.58E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.02 1.50E-02 1.01E-06 1 8.85E-03 0.5 5.001-01 2.100-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.000200 0 0.00+E00 1 1.00E+00 0.00E+00 0.02 1.50E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 8.97E-01 1 9.97E-01 1 1.000+00 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.02 1.50E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.000+00
PCF
$80 WCCXXSUCTI SWTODG AAAA ACHFDRCOFF 384 TI0000SW ACAA.L10OX ACLOPNOS12 ACLOPRT751 ACTRAINA ACTRAINB DGlANOTRUN DG1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX AAAA ACHFDRCOFF 385 TI000OSW ACAAO.1 OX ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX WAA ACHFDRCOFF 386 TI00O0SW ACAAO100X ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINS AFAZFAILXX DGIANOTRUN DGIBNOTRUN NOSSO PCF SBO SWCCIPUMPSR SWITODG AAAA 387 TIOOOOSW ACAA0_10NX ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DG1 BNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA 388 TI000CSW ACAAO.. OX ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX AAAA 389 TI1000SW ACAA0_100X ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DGIANOTRUN DGIBNOTRUN NOSBO PCF SWCOCSUCTI SWTODOG TRANSX AAAA 390 TIO0O0SW ACAA100_0X ACAZDLOSPI ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB AFAXITDAFW DG1ANOTRUN DGIBNOTRUN PCF 58O SWTMPUMPIA SWTMPUMP1C SWTODG ACHFDRCOFF 391 TIO0OOSW ACAAI00OX ACAZDLOSPI PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to D0 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offshe power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO $S CONDITION FOR LOOP Loss of Offsute Circuit 751 Following Reactor Top TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Fallur Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTBETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12AAND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loon of Offsite Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12AAND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Ag Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps Undependent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loon of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AlH Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps independent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to 00 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 8/100 (CKT 751 SUPPLYING BUSES 12A AND 128)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of An Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 0/100 (CKT 751 SUPPLYING BUSES 12A AND 128)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Alt Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to 0G (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE WV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128)
Failure to Reotow Offsite Power Within 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -0D B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
Fallure to recover second offsite power circuit after taioure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Falure to Restore Offsite Power Within 1 Hour 0.88 8.76E-01 1 1.00E+00 1.0gE-04 1.OOE-04 1 1.00E+00 0 g.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.02 1.50E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00+E00 1 1.00E+00 0 8.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.02 1.50E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00+E00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 0 0.008E00 0.1 1.00E-01 1 1.00E+00 0.008+00 0.02 1.50E-02 0.5 5.00E-01 2.18E-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.00+E00 0.88 8.768E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00+E00 1 1.00E+00 0.00E+00 0.02 1.50E-02 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.008-04 1 1.00E+00 0 0.00E+00 I 1.00E+00 8.00E+00 0.02 1.50E-02 0.5 5.00E-01 2.10E-03 2.110E-03 I 1.00E+00 I 1.80E+80 I 9.97E-01 I 9.97E.01 I 1.00E+00 0.88 8.76E-01 121E-04 1.21E-04 0 5.00-E+0 I 1.00E+00 0 0.00E+00 I 1.00E+00 0.00E+00 0.02 1.80E.02 0.5 5.00E.01 2.10E-03 2.10E-03 I 1.00E+00 I 1.00E+00 I 9.97E-01 I 9.97E-01 1 1.0012+00 0.88 8t.76E-01 1.00E-04 1.00E-04 I 1.00ED00 I 1.00E+00 0 0.00E+00 I 1.00E+00 0.00E+00 0.14 1.44E-01 0.3a 3.81E-01 1.01E-06 1 8.85E.-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00)
I 1.00E+00 1 9.97E-01 I 9.97E-01 0.88 8.76E-01 I 11.00E+00 0.03 3.13E.02 0.04 3.56E.02 1 11.00E+00 0.1 1.00E-011 I 1.00E+00 0.00E+00 0.14 1.44E-01 0.38 3.811E-01
ACB2FIBS17 ACLOPNOSI2 ACLOPRTI767 ACTRAINA ACTRAINB DOIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWTMPUMPIA SWTMPUMP1C SWTODG AAAA ACHFDRCOFF 392 T10000SW ACAAI00 0X ACAZDLOSPI ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAX1TDAFW DGlANOTRUN DG1BNOTRUN PCF S80 SWTMPUMPIA SWTMPUMPIC SWTODG 393 T10000SW ACAA11000X ACAZOLOSPI ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SB6 SWTMPUMP1A SWTMPUMP1C SWTODG AAAA 394 T10000SW ACAAI 00-OX ACAZDLOSPI ACB2FIB181 ACLOPNOSI2 ACLOPR1T77 ACTRAINA ACTRAINB AFAXITDAFW DGIANOTRUN DGIBNOTRUN PCF SBO SWTMPUMP1B SWTMPUMPID SWTODG ACHFORCOFF 395 TI0000SW ACAAIO0_OX ACAZDLOSPI ACB2FIBS18 ACLOPNOSI2 ACLOPRT7B7 ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF SBO SWTMPUMPIB SWTMPUMP1D SWTODG AAAA ACHFDRCOFF 3986 TI000SW ACAA10CLOX ACAZDLOSPI ACB2FIBS1O ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAXITDAFW DG1ANOTRUN DGI8NOTRUN PCF S80 SWTMPUMP1 B SWTMPUMP1D SWTODG 397 TI0000SW ACAA1 00_OX ACAZOLOSPI ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS DG1ANOTRUN DG18NOTRUN NOSBO PCF 880 SWTMPUMP1B SWTMPUMP1D Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offitne power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 128)
Failure to Restore Offste Power Within 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A in maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
Total Loss of Seicae Water FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B)
Failure to Restore Offsite Power Within 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A In maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Failure to Restore Offste Power Within 1 Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offslte Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Failure to Restore Offsite Power Within 1 Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Tfip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump Bin maintenance SW Pump D in maintenance TAG - SW Lost to DO (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsfte power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128)
Failure to Restore Ofisite Power Within 1 Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Top TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Failure to Restore Offsoe Power Within 1 Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Alt Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump B in maitenanoce SW Pump D in maiotenance 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 I
9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.001+00 0.03 3.13E-02 0.04 3.06E-02 I 1.00E+O0 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.14 1.44E-01 0.38 3.81E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 0.03 3.13E-02 0.04 3.068-02 1 1.00E+00 1 1.00E+00 0.00E+00 0.14 1.44E-01 0.38 3.81E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 0.03 3.13E-02 0.04 3.50E-02 1 1.00E+00 0 0.00+E00 1 1.00E+00 0.008+00 0.14 1.446-01 0.38 3.81E-01 1.01 E-06 1 8.85E-03 0.0 5.00E-01 2.12E-03 2.128-03 1 1.00E÷00 1 1.001+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.78E-01 1 1.00E+00 0.05 4.55E-02 7.151-03 7.15E-03 1 1.00E+00 0.1 1.008-01 1 1.00E800 0.00E+00 0.14 1.44E-01 0.38 3.81E-01 1.01E-06 1 8.85E-03 0.5 5.00E-i1 2.12E-03 2.128-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.151-03 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.008E00 0.00E+00 0.14 1.446-01 0.38 3.81E-01 1.01 E-06 1 8.85E-03 0.8 9.00E-01 2.10E-03 2.10E-03 1 1.008+00 I 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.156-03 1 1.00E+00 1 1.008E00 0.00E+00 0.14 1.446-01 0.38 3.81E-01 1.01E-06 1 8.85E-03 0.5 9.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.008+00 1 9.972-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 0.08 4.80E-02 7.1tE-03 7.15E-03
SWTODG TAG - SW Lost to DG (cooling) 1 1.001+00 AAA 398 T10000SW ACAAI00_0X ACAZDLOSP1 ACLOPNOSI2 ACLOPRT787 ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 399 TI0000SW ACAA100_OX ACAZDLOSP1 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGlANOTRUN DG1 BNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 400 TI0000SW ACAA100OX ACAZDLOSPI ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA 401 TI0000SW ACAA100..OX ACAZDLOSP1 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA 402 T10000SW ACAA100OX ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINE AFAZFAILXX DG1ANOTRUN DGIBNOTRUN NOSEO PCF SBO SWrMPUMPIA SWTMPUMP1C SWTODG AAAA ACHFDRCOFF 403 T10000SW ACAA100 0X ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB D*IANOTRUN DGIBNOTRUN NOSBO PCF SWCCPUMPSS SWTODG TRANSX AAAA ACHFDRCOFF 404 T10000SW ACAA1 00_OX ACB2FI5S17 ACLOPNOSt2 ACLOPR1767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWMMOSWPAS SWTMPUMPtC SWTODG TRANSX AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES M2A AND 12B)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offate Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Servce Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsfte power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 6 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second atnsite power circuit after flaure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPUES BUSES 12A AND 128)
Failure to Restore Offsite Power Within I Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 128)
Failure to Restore Offsite PowerWfithin 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND lB FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps lindependent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A In maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after faltre of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fauit on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND l8 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Fallure Of Service Water Pumps To Start TAG - SW Lost to DOG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after fauure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START SW Pump C In maintenance TAG - SW Lost to D1 (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 1 1.006+00 0.00E+00 0.14 144E-01 0.38 3.81E-01 0.0 5.00E-01 2.12E-03 2.121-03 1 1.00E+00 1 1.OE+÷00 1 6.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.002+00 0.14 1.44E-01 0.38 3.81E-01 0.5 5.002-01 2.121-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.008E00 0.00E+00 0.14 1.44E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.002E00 1 1.00E+00 1 0.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.14 1.44E-01 0.38 3.81E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.002+00 1 1.002+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.008+00 1.00E-04 1.008-04 1 1.00E+00 0 0.001200 1 1.00E+00 0.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.122-03 2.12E-03 1 1.008+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.002+00 0.03 3.13E-02 0.04 3.50E-02 1 1.00E+00 O 0.00E+00 0.1 1.00E-01 1 1.00+E00 0.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.002-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.001200 0 0.00E+00 0.1 1.00E-01 1 11.0012+00 0.0012+00 0.14 1.44E-01 1.01E-00 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.972-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 3.282-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 I 11.00E+00 0 0.00E÷00
ACHFDRCOFF Failurm to recoversecond offsie power circuit after faaiure of first 0.1 11.0E-01 405 TI0000*W ACAA100OX ACB2FIES1 7 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWMMOSWPCS SWTMPUMP1A SWTODG TRANSX AAAA ACHFDRCOFF 406 TI0000SW ACAA1000X ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGISNOTRUN NOSBO PCF SWTMPUMP1A SWTMPUMP1C SWTODG TRANSX AmA ACHFDRCOFF 407 TIOO0OSW ACAA100JX AC82FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DG1ANOTRUN DOGIBNOTRUN NOSBO PCF SBO SWTMPUMP1A SWTMPUMPIC SWTODG AAAA 408 TI000OSW ACAA100_OX ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINE D*lANOTRUN DG1BNOTRUN NOSBO PCF SWCCPUMPSS SWTODG TRANSX AAAA 409 TIOOOOSW ACAA1 O0OX ACB2FIBSI7 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SWMMOSWPAS SWTMPUMP1C SWTODG TRANSX AAAA 410 TI0000SW ACAA`100JX ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWMMOSWPCS SWTMPUMPIA SWTODG TRANSX AmAA 411 TI000OSW ACAA1 00_OX AC82FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINE DG1ANOTRUN DGIBNOTRUN NOSBO POF SWrMPUMPIA SWTMPUMPIC SWTODG TRANSX Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsote Circuit 767 Following Reactor Tdp TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsto Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Falure of AC Train B FLAG - DG lA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsie power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B)
Locel Fauot on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Alt Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Etec Faluret of all MDAFW pumps independent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failre of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - 0G B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-She Power Following Reactor Trip TAG - Failure atACG Train A TAG - Failure of AC Train B FLAG - DOG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 10010 (CKT 787 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Foltoiag Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 787 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DOG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C In maintenance TAG - SW Lost to DO (cooling)
TAG - TRANSIENT EVENT 1 1.00E+00 0.OOE+00 0.14 1.44E-01 1.01E-o06 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E-00 1 1.00E+00 1 9.97E-01 1 9.07E-01 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+80 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00Eu00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.001+00 1 1.00E800 1 9.87E-01 1 9.97E-01 1 1.00E200 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.001-01 1 1.00E+00 0.00E+00 0.14 1.44E-01 1.01E-06 1 8.85F-03 0.5 5.00E-01 2.101-03 2.10E-03 1 1.00E+O0 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.971-01 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0 0.00Ee00 I 1.00E+00 8.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.008-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 I
9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 I 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 O.00+E00 0.14 1.44E-01 1.018-00 1 8.85E-03 0.5 5.00E-01 2.108-03 2.1OE-03 1 1,00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.008E00 0.88 8.76E-01 3.28E-03 3-28E-03 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0 0.00E+000 1 1.008+00 0.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 I 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.80 8.76E-01 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.08E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.008+00 0.14 1.44E-01 1.011E-08 1 8.86E-03
.05 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00
AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 412 TISOOOSW ACAA100O0X ACB2FIBS18 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DG1ANOTRUN DGI BNOTRUN NOSBO PCF SWCCPUMPSS SWTODG TRANSX AAAA ACHFDRCOFF 413 TIOOOOSW ACAA100J0X ACB2FIBS18 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF SWMMOSWPDS SWTMPUMP1B SWTODG TRANSX AAA ACHFDRCOFF 414 TIOOOSW ACAAM100OX ACB2FIBS18 ACLOPNOS12 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWTMPUMPIB SWTMPUMP1D SWTODG TRANSX AAAA ACHFDRCOFF 415 TIOOOOSW ACAA100X ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIIBNOTRUN NOSBO PCF SWCCPUMPSS SWTODG TRANSX AAAA 416 TI0000SW ACAA100_0X ACB2FIBS18 ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF SWMMOSWPDS SWTMPUMPIB SWTODG TRANSX AMMA 417 TI0000SW ACAA100_OX ACB2FIBSI8 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWTMPUMP1B SWTMPUMP1D SWTODG TRANSX AAMM 418 TI0000SW ACAA10OX ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DGIBNOTRUN NOSBO PCF SBC SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offstte Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Case Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 125)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of OffsIte Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP D TO START SW Pump B in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second oflsite powercircuit after faiure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recoversecoaid offsote power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Ait Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 10 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Anl Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP D TO START SW Pump B in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AD Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train 8 FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps findependent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Canoe Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first I 1.00E+00 0.00E+00 0.14 1.44E-a1 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 I 9.97E-01 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.001+00 0 0.00E+00 0.1 1.00E-01 I 1.00E+00 0.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-O1 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 1 1.00E+00 0.8 8.76E-01 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.00E+00 I 1.00E+00 0 0.00E+00 0.1 1.001-01 1 1.00E+00 0.00E+00 0.14 1.44E-01 1.01 E-06 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 I 1.00E+00 1 1.00E+00 1 9.97E-01 1 0.97E-01 I 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.14 1.44E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 3.28E-03 3.28E-03 0.00 4.55E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.14 1.44E-01 1.01E-06 1 8.85E-03 0.0 5.00E-01 2.108-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 0.05 4.55E-02 7.15E-03 7.115-03 1 1.002+00 1 1.00E+00 0 0.00E+00 1 1.008+00 0.00+E00 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 I 1.OOE+00 1 1.00E+00 0.1 1.00E-01 I 9.97E-01 1
.97E8-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01
419 TI0000SW ACAA100O0X ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB AFAZFAILXX DGlANOTRUN DGIBNOTRUN NOSSO PCF SBO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 420 T10000SW ACAA100 0X ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF SWCCIPUMPSR 8WTODG TRANSX AAAA ACHFDRCOFF 421 T10000SW ACAA100_OX ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX AAAA ACHFDRCOFF 422 T10000SW ACAA10_OX ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DG1IBNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA 423 TI0000SW ACAA100_OX ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DG1ANOTRUN DG1BNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA 424 T10000SW ACAA100_0X ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX AAAA 425 T10000SW ACAA100 0X ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX AAAA 426 T10000SW ACAAS0O50A ACAASO_50N ACAZDLOSPI ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB AFAXITDAFW DGIANOTRUN Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offs/te Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure ofAC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DO B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsie power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offshe power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 16 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offste power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of at MDAFW pumps (Independent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure ofall MDAFW pumps (independent of AF300)
FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 100/0 (CKT 767 SUPPLIES BUSES 12A AND 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DO (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 10010 (CKT 767 SUPPLIES BUSES 12A AND 128)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Ali Off-Site Power Following ReactorTrip TAG - Failure of AC Train A TAG - Failure of AC Train 8 FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to DOG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 126, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
Failure to Restore Offsite Power Whhin 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offshie Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG tA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 1.00E+00 0.00E+00 0.14 1.44E-01 0.8 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 I
9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.006-04 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.002-01 1 1.00E800 0.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.218-04 1 1.00E+00 1 1.00E+00 0 0.008+00 0.1 1.00E-01 1 1.00E800 0.00E+00 0.14 1.44E-01 0.5 5.001-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.006-04 I 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.002-01 I 1.00E+00 0.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.008+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.216-04 1.21E-04 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.008+00 0.14 1.44E-01
- 0.
5-00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.008+00 0.1 1.00E801 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 I 1.00E+D0 1.00E-04 1.00E-04 I 1.00E+00 0 0.OOE+00 1 1.00E+00 0.00E+00 0.14 1.44E-01 0.5 5.00E-01 2.101-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.14 1.44E-01 0.5 5.008-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.008+00 1
98.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 O.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.38 3.81E-01 0.5 5.00E-01 2.128-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 1.008+00 1 9.97E-01
DGIBNOTRUN PCF SBO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 427 TIOOOOSW ACAASO50A ACAASOSON ACAZDLOSPI ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB AFAXITDAFW DGIANOTRUN DGIBNOTRUN PCF SBO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 428 TI0OOSW ACAASO50A.
ACAASO_50N ACAZDLOSPI ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DGlANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 429 T10000SW ACAA50_50A ACAA50 50N ACAZDLOSP1 ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SB SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 430 TI0000SW ACAAS_-50A ACAASOSON ACAZDLOSPI ACLOPNOSI2 ACLOPRT787 ACTRAINA ACTRAINB AFAXITDAFW DG1ANOTRUN DG18NOTRUN PCF SBO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 431 TI000SOW ACAASO50SOA ACAAS0 5ON ACAZDLOSPI ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB AFAX1TDAFW DG1ANOTRUN DGIBNOTRUN PCF SBO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 432 T10000SW ACAAS_50OA ACAASO-50N ACAZDLOSPI ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 433 T10000SW ACAAS0.5A ACAA50.5ON ACAZDLOSPI ACLOPNOSI2 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
Failure to Restore Olfste Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following ReactorTrip TAG - Failure of AC Train A TAG - Faulure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/SO NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B)
Failure to Restore Offsie Power Within I Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsfte Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Fa/ure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsIhe power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128)
Failure to Restore Offsite Power Wthin 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 707 TO BUS 12A)
FLAG - OFFOITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B)
Failure to Restore Offsite PowerWtlhin I Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offite Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE IV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B)
Failure to Restore Offsite Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Off/ste Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to DO (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128)
Failure to Restore ODsire Power Within 1 Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 0 81 NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Fa/lure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128)
Fa/lure to Restore Offsite Power Within I Hour CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 1 9.971-01 0.88 8.78E-01 1 1.00E+00 1.21E-04 1.21E-04 I 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.001+00 0.83 8.25E-01 0.02 1.70E-02 0.38 3.81E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.00OE00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.38 3.818-01 0.6 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 8.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E800 1.21E-04 1.21E-04 1 1.00E+00 0 O.00E+00 0.1 1.008-01 1 1.00E+00 0.001E00 0.83 8.25E-01 0.02 1.70E-02 0.38 3.81E-01
.05 5.008-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E+00 1.00E-04 1.008-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.38 3.818-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.OOE+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.708-02 0.38 3.81E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 1.001+00 1 9.97E-01 1 9.97E-01 0.88 8.76E-01 1 1.00E+00 1.008-04 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.258-01 0.02 1.70E-02 0.38 3.81E-01 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 I
9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0.00E+00 0.1 1.00E-01 I 1.00E+00 0.008+00 0.83 8.25E-01 0.02 1.708-02 0.38 3.81E-01 0.5 5.00E-01
ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DG1BENOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 434 TIODOOSW ACAA50L.S0A ACAAS0_5ON ACB2FIBS17 ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DG1ANOTRUN DG1 BNOTRUN NOSBO PCF SWTMPUMPIA SWTMPUMP1C SWTODG TRANSX AAAA ACHFDRCOFF 435 TI000OSW ACAA50SQOA ACAASOS0N ACB2FIBS17 ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWTMPUMPIA SWTMPUMPIC SWTODG TRANSX AAAA ACHFDRCOFF 436 T10000SW ACAAS30-OA ACAA50-50N ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DG1BNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 437 T10000SW ACAA50O50A ACAASOJ50N ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DGI BNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF 438 T10000SW ACAA5050A ACAA50._50N ACLOPNOSI2 ACLOPRT751 ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX AAAA ACHFDRCOFF 439 T10000SW ACAASL-50A ACAAS0q50N ACLOPNOS12 ACLOPRT751 ACTRAINA ACTRAINB DGIANOTRUN DG1 BNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX AAAA ACHFDRCOFF Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG -DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to 00 (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after falurm offirst Total Loss of Service Water FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 787 TO BUS 128)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsie Crcuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second of/slte power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/SO ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/SO NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offske Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Faiure to recover second onslte power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50150 NORMAL (CKT 751 TO BUS 12A, CKOT 787 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offshe Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
FLAG -0 0; IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - O B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second ofnsthe power circult after fa/lure of find Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of al MDAFW pumps (independent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION ONITIATOR)
TAG - SW Lost to 0G (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second of/tsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/SO NORMAL (CKT 751 TO BUS 12A, CK'T 767 TO BUS 128)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsie Circuit 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - 0G B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsle power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CK'T 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/SO NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 128)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offs/le Circait 751 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DO 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - 0G0 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second of/tie power circuit after failure of first 2.12E-03 2.12E-03 1 1.00E-00 1 1.OOE+00 1 9.97E-01 I 9.97E-01 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.008-O4 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.008-01 I 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.70E-02 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-O1 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0 0.008+00 0.1 1.0OE-01 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.70E-02 1.01E-00 1 8.85E-03 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 i.0OECO0 1 9.97E-01 1 9.978-01 1 1.00E+00 0.88 8.78E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00+E00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.008+00 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.OOE+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.008+00 0.1 1.001-01 1 9.97E801 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.008+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.53 8.25E-01 0.02 1.70E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.978-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.008E00 1 1.008E00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.008E00 0.83 8.25E-01 0.02 1.70E-02 0.5 5.001-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E800 1 1.00E+00 0 0.OO12+00 0.1 1.00E-01
440 TIOOOSW ACAAO_50A ACAAOO N50 ACLOPNOSI2 ACLOPRT787 ACTRAINA ACTRAINB AFAZFAILXO DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA ACHFDRCOFF 441 T10000SW ACAA0_J50A ACAA5S50N ACLOPNOSI2 ACLOPRT787 ACTRAINA ACTRAINB AFAZFAIL.XX DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA ACHFDRCOFF "442 110000SW ACAAS0_50A ACAA50_50N ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX AAAA ACHFDRCOFF 443 71000OSW ACAA50 50A ACAAS0OJON ACLOPNOSI2 ACLOPRT767 ACTRAINA ACTRAINB DGIANOTRUN DGI BNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX AAAA ACHFDRCOFF 444 T10000SW ACAASO_50A ACAZDLOSPi AC82FIBS17 ACB2FTBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SBO SWTODG AAAA "440 TI0000SW ACAA5O0.50A ACAZDLOSP1 ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAXITDAFW DGIANOTRUN DGIBNOTRUN PCF 80 SWTMPUMPIA SWTMPUMP1C SWTODG 448 T10000SW ACAA50-50A ACAZOLOSPI ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF S2O SWCCPUMPSS SWTODG AAAA Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 122, CKT 767 TO BUS 12A)
FLAG - OFFPITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 122)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to 0G (coolng)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Falure to recover second offshie power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure ofall MDAFW pumps (independeot of AF300)
FLAG - DG IA IS NOT RUNNING ANDTIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 10 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR)
TAG - SW Lost to D1 (cooling)
FACTOR TO EUMINATE UVAND ILLOGICAL CUTSETS Falour to recover second offshe power circuit after fanure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 787 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 787 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsihe Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsfte power circuit after failure of irat Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKr 767 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsee Circuit 787 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - SW Lost to D0 (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Offatte Power Within 1 Hour Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Top TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DI IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TAG - SW Lost to D0 (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128. CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Within I Hour Local Fauft on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of At Off-Shie Power Following Reactor Trip TAG - Failure of AC Train A TAG - Falure of AC Train B TAG - TDAFW Pump operates successfully FLAG - D0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A in maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Failure to Restore Offshe Power VWthin 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Faollre of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 1 1.00E+00 0.002+00 0.83 8.25E-01 0.02 1.70E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 l.005+00 0.1 1.00E-01 1 9.97E-01 I
9.97E-01 1 1.002+00 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E200 0.1 1.00E-01 1 1.00E200 O.002E00 0.83 8.25E-01 0.02 1.70E-02 0.5 5.002-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.972-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00+E00 0.00E+00 0.83 020E201 0.02 1.70E-02 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 I 1.00E+00 1 0.97E-01 1 9.97E-01 1 1.002+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 I 1.00E+00 0.00E+00 0.83 8.25E-01 0.02 1.70E-02 0.5 S.00E-01 2.12E-03 2.12E-03 1 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 1 1.002+00 0.88 8.78E-01 1.00E-04 1.00E-04 1 1.002+00 11 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E÷00 0.001+00 0.83 8.25E-01 0.38 3.81E-01 1.012-06 1 8.85E-03 1.01E-06 72 7.27E-05 0.5 8.00E-01 2.10E-03 2.110E-03 I 1.00E+00 1 1.00E÷00 1 9.97E-01 I 9.97E-01 I 1.00E+00 0.88 8.76E-01 1 1.0012+00 I 1.00E+00 0 0.00E+00 I 1.00E+00 0.00E+00 0.83 8.25E-01 0.38 3.8112-01 1.01E-06 I 8.85E-03 0.5 6.00E-01 2.10E=-03 2.10E-03 1 1.0012+00 I 1.00E-00 I 1.00E+00 I 9.97E-01 I 9.97E-01 0.88 8.76E-01 I 11.00E+00 0.03 3.13E-0T2 0.04 3.56E-02 I 1.00E+00 I 1.00E+00 0.0012+00 0.83 8.25E-01 0.38 3.81E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.110E-03 1 1.00E+00 1 1.00E÷00 1 9.9712-011 1 9.9712-011 1 1.00E+00 0.88 8.76E-01 1 1.O0E+00 1.14E-04 1.14E-04 1 1.00E÷00 0 0.00E÷00
447 T100O0SW ACAA50_50A ACAZDLOSPI ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1lBNOTRUN NOSBO PCF SBO SWMMOSWPAS SWTMPUMPIC SWTODG AAAA "448 TIDOOOSW ACAAS0_5OA ACAZDLOSP1 ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWMMOSWPCS SWTMPUMP1A SWTODG AAAA 449 TIOOOSW ACAASO_50A ACAZDLOSPI ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWTMPUMP1A SWTMPUMPIC SWTODG AAAA 450 T10000SW ACAASO_50A ACAZDLOSPI ACB2FIBS18 ACB2FTBS17 ACLOPNOSI2 ACLOPRTALL.
ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF
$5O SWTODG A*AA 451 T10000SW ACAASO50A ACAZDLOSPI ACB2FIBS18 ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINB AFAXITDAFW DG1ANOTRUN DGIBNOTRUN PCF SBO SWTMPUMPIB SWTMPUMPID SWTODG 452 TIOOOOSW ACAASO5_0A ACAZDLOSP1 ACB2FIBSI8 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGISNOTRUN NOSBO PCF SO SWCCPUMPSS SWTODG AAAA 453 T10000SW ACAASOSSA ACAZDLOSP1 ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1 BNOTRUN NOSBO PCF SBO SWMMOSWPDS SWTMPUMP1B Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Oflsite Power Within 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Falluo of AC Train A TAG - Failure of AC Train B FLAG - DGlIA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE FAILURES OF SW PUMP A TO START SW Pump C In maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Failure to Restore Offslte Power Within 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Alt Off-Sie Power Following Reactor Trip TAG - Failure of AC Train A TAG - Fauture of AC Train B FLAG - DO;IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Failure to Restore Offsieo Power Within 1 Hour Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Within I Hour Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Faulure of AC Train S FLAG - D0 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS I1A)
Failure to Restore Offsite Power Within 1 Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AS Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Faoure of AC Train B TAG - TDAFW Pump operates successfully FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump B in maintenance SW Pump D In maintenance TAG - SW Lost to 00 (cooling)
Total Loss of Service Water FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
Failure to Restore Offsle Power Within I Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Fauure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Fatlure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Failure to Restore Offsite Power Within 1 Hour Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Ali Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DO IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - D0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE FAILURES OF SW PUMP D TO START SW Pump B in maintenance 1 1.00E+00 0.OOE+00 0.83 8.25E-01 0.38 3.81E-01 101E-06 1 8.85E-03 0.5 5.00E-O1 2.10E-03 2.10E-03 I 1.08E+00 1 1.005+00 1 9.97E-01 1
9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.005+00 0.83 8.25E-01 0.38 3.81E-01 1.01E-OS 1 8.85E-03 0.5 505E-01 2.10E-03 2.10E-03 1 1.05E+00 1 1.80E+00 1 9.97E-01 1 9.97E-01 1 1.80E+80 0088 8.76E-01 I 1.00E-*0 3.28E-03 3.28E-03 0.03 3.13E-02 I 1.OOE00 0 0.05E+00 1 1.00E+00 0.80E+00 0.83 8.25E-01 0.38 3.81E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E5O0 0.88 8.76E-01 1 1.05E+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E500 0 0.00E+00 1 1.001O20 0.05E+00 0.83 8.26E-01 0.38 3.81E-01 1.01E-06 1 8.85E-03 1.01E-08 72 7.27E-05 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.80E+80 1 8.87E-01 1 9.97E-01 1 1.00E+50 0.88 8.76E-01 1 1.05E+00 1 1.00E+00 0 0.80E+00 1 1.80E+00 0.00E+00 0.83 8.25E-01 0.38 3.81t-01 1.01 E-06 1 8.85E-03 0.5 5.05E-01 2.105-03 2.10E-03 1 1.00E+00 1 1.05E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 0.88 8.78E-01 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.1155-03 I 1.00E+00 1 1.00E+00 0.00E÷00 0.83 8.25E-01 0.38 3.81E-01 1.01E-06 I 8.85E-03 0.5 5.00E-01 2.110E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 E 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.14E-04 1.14E-04 1 9.975-01 1 1.005+80 0 1.805+00 I 11.00E+00 0,00E+00 0.83 8.25E-01 0.38 3.81E-01 1.01E-06 1 8.8515-03 0.5 5.00E-011 2.,t0E-03 2.110E-03 I 1,00E+00 I 1.00E+00 I 9.97E-01 I 9.97E-01 1 1.00E+00 0.88 8.76E-01 I 1.00E+00 3.28E-03 3.28E-03 0.05 4.55E-02
SWTODG AAAA 454 TI0000SW ACAA50_50A ACAZDLOSPI ACB2FIBS1S ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWTMPUMP1B SWTMPUMP1D SWTODG AAAA 455 TI000SW ACAA5O0LOA ACAZDLOSP1 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN 1DGIBNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA 456 T10000SW ACAASO_50A ACAZDLOSPI ACLOPNOSI2 ACLOPRTAL.
ACTRAINA ACTRAINB DG1ANOTRUN Dl 1BNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA 457 T10000SW ACAA5_S50A ACAZDLOSPI ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINB DGIARUN DG1BNOTRUN DGAZRUNDGA NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA 458 TIOO70SW ACAA5OL50A ACB2FIBS17 ACB2FIBS18 ACLOPNOS12 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN DGAAINTAKE NOSBO PCF SWAZINTAKE SWTODG TRANSX AAAA 450 T10000SW ACAA50_50A ACB2FIBS17 ACB2FTBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG18NOTRUN NOSBO PCF SWTODG TRANSX AAAA 460 T10000SW ACAAS0_.0A ACB2FIBSI7 ACLOPNOSI2 ACLOPRT751 ACTRAINB AXMMSAFWPC DGIBNOTRUN NOSBO PCF SWTMPUMP1A SWTMPUMP1C SWTODG TRANSX 461 TI0000SW ACAA50.50A ACB2FIBS17 TAG - SW Lost to DG (cooling) 1 1.008E00 FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water 1 1.00E+00 0.00E+00 FLAG - OFFSITE POWER MODE 00150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A) 0.83 3.25E-01 Failure to Restore Offshe PowerWfthirt I Hour 0.38 3.811-01 Local Fault on 480 VAC Bus 18 1.01E-06 1 0.865-03 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of All Off-Site Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG. DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 SW Pump B in maintenance 0.05 4.55E-02 SW Pump D in maintenance 7.15E-03 7.10E-03 TAG - SW Lost to DG (cooling) 1 1.008+00 FACTOR TO EUMINATE UV AND ILLOGICAL CUTSETS 0 0.00E-00 Total Loss of Service Water 1 1.00E+00 0.00E+00 FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 Failure to Restore Offsfte Power Within 1 Hoar 0.38 3.81E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of At Off-Site Power Followiog Reactor Trip 2.108-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 Common Camse Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 FACTOR TO EUMINATE UV AND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water 1 1.00E+00 0.001+00 FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 777 TO BUS 12A) 0.83 8.25E-01 Failure to Restow Offslte Power Within 1 Hour 0.38 3.61E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of All Off-Shte Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.978-01 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - STATION BLACKOUT SEQUENCE I 1.00E+00 TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 TAG - SW Lost to 00 (cooling) 1 1.00E+00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water 1 1.00E+00 0.00E+00 FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 126, CKT 767 TO BUS 12A) 0.83 8.25E-01 Failure to Restore Offshe Power Within 1 Hour 0.38 3.91E-01 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of AD Off-Ste Power Following ReactorTrip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG-Failure of AC Train B 1 1.00E+00 FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 15 0.03 3.00E-02 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS 0.1 1.00E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - STATION BLACKOUT SEQUENCE 1 1.00E+00 Common Cause Failure Of Service Water Pumps To Run 1.21E-04 1.21E-04 TAG - SW Lost to DG (cooling) 1 1.00E+00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.008+00 Total Loss of Service Water I 1.00E+00 0.00E+00 FLAG - OFFSITE POWER MODE 50/50 ALT (ClKT 751 TO BUS 12B, CKr 767 TO BUS 12A) 0.83 8.25E-01 Local Fault on 480 VAC Bus 17 1.01E-06 1 0.85E-03 Local Fault on 480 VAC Bus 18 1.01E-06 I 9.85E-03 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP 0.9 0.00E-01 Loss of Al Off-She Power Following Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A 1 1.00E+00 TAG - Failure of AC Train B 1 1.00E+00 FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1 9.97E-01 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-01 FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED 0.12 1.23E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (32/2052 hOs) 0.02 1.66E-02 TAG - SW Lost to DG (cooling) 1 1.00E+00 TAG - TRANSIENT EVENT 1 1.00E.00 FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 0 0.08E+00 Total Loss of Service Water 1 1.00E+00 O.00E+00 FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E-03 Local Fault on 480 VAC Bus 19 1.01E-06 72 7.27E-05 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.006-01 Loss of AS Off-She Power Followeing Reactor Trip 2.10E-03 2.10E-03 TAG - Failure of AC Train A I 1.00E+00 TAG-Failureof AC Train B 1 1.00E+00 FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 1
9.97E-01 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1
9.97E-01 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 TAG - SW Lost to DG (cooling) 1 1.0082-00 TAG - TRANSIENT EVENT 1 1.00E+00 FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 0 0.00E+00 Total Loss of Service Water 1 1.00E+00 0.00E+00 FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A) 0.83 8.25E-01 Local Fault on 480 VAC Bus 17 1.01E-08 1 8.85E-03 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 Loss of Offslte Ciruist 751 Following Reactor Trip 2.12E-03 2.12E-03 TAG - Failure ofAC Train B 1 1.00E+00 Failure of SAFW Pump 1C train 0.02 2.29E-02 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 1 9.97E-O1 TAG - NO STATION BLACKOUT 1 1.00E+00 PLANT CAPACITY FACTOR 0.88 8.76E-01 SW Pump A Ir maintenance 0.03 3.13E-02 SW Pump C In maintenance 0.04 3.56E-02 TAG - SW Lost to DG (cooling) 1 1.00E+00 TAG - TRANSIENT EVENT I 1.0oE+00 Total Loss of Service Water 1 1.00E+00 0.006+00 FLAG - OFFSITE POWER MODE 50050 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A) 0.83 9.25E-01 Local Fault on 480 VAC Bus 17 1.01 E-0 1 8.S5E-03
ACLOPNOSI2 ACLOPR'767 ACTRAINA ACTRAINB AXMMSAFWPD DGIANOTRUN NOSBO POF SWTMPUMPIA SWTMPUMPIC SWTODG TRANSX AAAA ACHFDRCOFF 462 T10000SW ACAASO.LOA ACB2FI8S17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DG1BNOTRUN NOSBO PCF SBO SWTMPUMP1A SWTMPUMP1C SWTODG AAAA 463 T10000SW ACAA50_50A ACB2FIBSI7 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AXMMSAFWPD DG1ANOTRUN NOSBO PCF SWrMPUMP1A SWTMPUMPIC SWTODG TRANSX AAAA 464 TI00005W ACAASO50A ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1 BNOTRUN NOSBO PCF SWCCPUMPSS SWTODG TRANSX AAAA 465 T10000SW ACAASO 50A ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1 BNOTRUN NOSBO PCF SWMMOSWPAS SWTMPUMPIC SWTODG TRANSX AAAA 466 T10000SW ACAASOS50A ACB2FIB17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SWMMOSWPCS SWTMPUMPIA SWT"ODG TRANSX AAAA 467 T10000SW ACAA50.50A ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1 BNOTRUN NOSBO PCF SWTMPUMP1A SWTMPUMPIC SWTODG TRANSX AAAA 468 TIO000SW ACAAS0S50A ACB2FIBS17 ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 767 Folkowing Reactor Trip TAG - Failurs of AC Train A TAG - Failure of AC Train 8 Failure of SAFW Pump ID Train FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of flirst Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
Local Fault on 480 VAC BUs 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to 0G (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 5/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Followong ReactorTrip TAG - Failure of AC Train A TAG - Failure of AC Train B Failure of SAFW Pump ID Train FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128. CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG -0 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AD Off-Shie Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP A TO START SW Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
Local Faust on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Ste Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG1 A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP C TO START SW Pump A in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Bite Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.5 5.00E-01 2.12E-03 2.12E-03 1 1.00E+00 I 1.00E+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.002+00 0.83 8.25E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.102-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 1 1.00E÷00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.83 825E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.002+00 0.02 2.29E-02 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.002+00 1 1.002+00 0 0.002+00 1 1.00E+00 O.00E+00 0.83 8.25E-01 1.01 E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 1.01E-00 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.03 3.13E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 1.01E-08 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.002+00 0 0.00E+00 1 1.002+00 0.002E00 0.83 8.25E-01 1.0112-06 1
8.85E-03 0.5 5.00E-01
ACLOPRTALL ACTRAINB AXMMSAFWPC DGISNOTRUN NOSBO PCF SWTMPUMP1A SWTMPUMPIC SWTODG TRANSX 469 T10000SW ACAAS0_50A AC82FIBS18 ACB2FTBS17 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF SWTODG TRANSX AAAA 470 T10000SW ACAA50_50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINS AFAZFAIL)O DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWTMPUMPIB SWTMPUMPID SWTODG AAAA 471 TIOOOOSW ACAA50_50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF SWAASWP1CR SWCVC04603 SWTMPUMP1B SWTODG TRANSX AAAA 472 T10000SW ACAA50_50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN 0G0 BNOTRUN NOSBO PCF SWCCPUMPSS SWTODG TRANSX AAAA 473 TIOOOOSW ACAASO_50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1BNOTRUN NOSBO PCF SWMMOSWPBS SWTMPUMP1D SWTODG TRANSX AMAA 474 TI000OSW ACAAS5 50A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SWMMOSWPDS SWTMPUMP1B SWTODG TRANSX AAAA 475 T10000SW ACAA0S0_S0A ACB2FIBS18 ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGlANOTRUN Loss of AN Off-Site Power Following Reactor Trip TAG - Failure of AC Train B Failure of SAFW Pump IC train FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR 3W Pump A in maintenance 3W Pump C in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Al Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Fallure ofAC Train B FLAG -0G IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 1ZA)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AKi Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps Ondependent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR.
TAG - STATION BLACKOUT SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG. DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 1 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01C Is In Operation Service Water Pump PSWIC Discharge Check Valve 4603 Fails To Close On Demand SW Pump B in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-Site Power Fotowing Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Start TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO EUMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Falure of AC Train B FLAG - D IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - 00 B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP B TO START SW Pump D In maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Alt Off-Site Power Following Reactor Trip TAG - Faoure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FAILURES OF SW PUMP D TO START SW Pump B in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE IV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 787 TO BUS 12A)
Local Fault on 480 VAC Bus 18 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG-Faiure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 2.10E-03 2.10E-03 1 1.00E+00 0.02 2.29E-02 1 9.97E-01 I l.00E+00 0.88 8.78E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.002+00 1 1.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 1.01E-OS 1 8.85E-03 1.01E-06 72 7.27E-05 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.008+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E800 1 1.00E+00 0 0.00E+00 1 1.00E+00 O.OOE+00 0.83 5.25E-01 1.011E-00 I 8.85E-03 0.5 5.00E-01 2.10E-03 2.1OE-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 I 1.00E+00 0.88 8.76E-01 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15-803 1 1.008+00 0 0.00E+00 1 1.00E+00 0.00E-00 0.83 8.25E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 5.84E-04 1 5.84E-04 0.05 4.55E-02 1 1.008+00 1 1.00E+00 0.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 1.01E-06 1 8.85E-03 0.5 5.008-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.87E-01 1 1.00E+00 0.88 8.76E-01 1.14E-04 1.14E-04 1 1.008+00 I 1.008E00 0 0.00E+00 1 1.00E+00 0.OOE+00 0.83 8.25E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2108-03 2.10E-03 1 1.008E00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 3.28E-03 3.28E-03 7.15E-03 7.158-03 1 1.00E+50 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 1.01E-08 1
8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.008+00 1 9.97E-01 1 9.97E-O1 1 1.00E+00 0.88 8.76E-01 3.28E-03 3.28E-03 0.05 4.55E-02 1 1.008E00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 1.01E-06 1 8.85E-03 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.972-01
DG18NOTRUN NOSBO PCF SWTMPUMPIB SWTMPUMP1 D SWTODG TRANSX AAAA 476 TI0000SW ACAA5050A ACLOPNOSI2 ACLOPRT751 ACLOPRT767 ACTRAINA ACTRAINB DG1ANOTRUN DG1BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX AAAA ACHFDRCOFF 477 TI0000SW ACAA50_50A ACLOPNOSI2 ACLOPRT751 ACLOPRT767 ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX AAAA ACHFDRCOFF 478 TIO0O0SW ACAA50J50A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DGI BNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG
.AAA 479 TI00SOOW ACAASO0.0A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAIL)CX DGIANOTRUN DGIBNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA 480 TI0000SW ACAAS5050A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN DGCCOOORUN NOSBO PCF SWCCIPUMPSR TRANSX AAAA 481 TI0000SW ACAASO_50A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGIBNOTRUN DGCCOORUN NOSBO PCF SWCXXSUCTI TRANSX AAAA 482 TI0000SW ACAA50_50A ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN DGDGF0001A DODGF0001B NOSBO PCF SWCCIPUMPSR TRANSX AAAA 483 TI00O0SW FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO St CONDITION FOR LOOP Loss of Offsite Circuit 751 Following Reactor Trp Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B. CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Offsite Circuit 751 Folowing Reactor Trip Loss of Offsite Circuit 767 Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Failure to recover second offsite power circuit after failure of first Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps Cindependent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Eloc Failure of all MDAFW pumps (Ondependent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 787 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Sihe Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 129, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Ali Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATORS FAIL TO RUN (COMMON CAUSE)
TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE S50/S ALT (CKT 751 TO BUS 128, CKT 767 TO BUS 12A)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of A)i Off-Site Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DGO IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DIESEL GENERATOR KDGO1A FAILS TO RUN DIESEL GENERATOR KDG0iB FAILS TO RUN TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water 1 9.97E-01 I 1.00E+00 0.88 8.78E-01 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 0 6.00E+00 I 1.00E+00 0.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.12E-03 2.12E-03 2.12E-03 2.12E-03 1 1.00E+00 1 1.008+00 1 8.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.28E-01 0.5 5.00E-01 2.12E-03 2.12E-03 2.12E-03 2.128-03 1 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.768-01 1.00E804 1.00E-04 1 1.00E+00 1 1.00E+00 0 0.00E+00 0.1 1.00E-01 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 I 1.008E+0 0.1 1.00E-01 1 8.97E-01 1 9.97E-1 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 1 1.00E+00 0 0.00E+00 1 1.008+00 0.008+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 I 1.00E+00 0 0.00E+00 1 1.00E+00 0.008+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 I 1.00E+00 1 1.00E+00 I 9.97E-01 1 9.97E-01 1.36E-03 1.38E-03 1 1.00E+00 0.88 8.78E-01 1.21E-04 1.21E-04 1 1.008E00 0 0.00E+00 1 1.00E+00 0.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 I
9.97E-01 1.38E-03 1.36E-03 1 1.008+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 0 0.00E+00 1 1.00E+00O0.00E+00 0.83 8.25E-01 0.5 5,00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E÷00 1 9.97E-01 1 9.97E-01 1.41E-03 24 3.38E-02 1.41E-03 24 3.38E-02 1 1.0012+00 0.88 8.76E-01 1.21E-04 1.21 Eo04 I 1.00E+00 0 0.00E+00 I 1.00E+00 0.00E+00
ACAA50_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of API Off-She Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWP18NR FLAG - Service Water Pump PSWOIB Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW01 D Is In Operation SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMPIA SW Pump A In maintenance SWTMPUMPIB SW Pump 8 in maintenance SWTMPUMP1C SW Pump C in maintenance SWTODG TAG - SW Lost to DO (cooling)
TRANSX TAG - TRANSIENT EVENT AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 484 TIO00SW Total Loss of Service Water ACAA5_W50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of Al Off-She Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINS TAG - Failure of AC Train B DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DGIBNOTRUN FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 NOSED TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW0I1B Is In Operation SWAASWP1 DR FLAG - Service Water Pump PSWO1D Is In Operation SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance SWTODG TAG - SW Lost to DG (cooling)
TRANSX TAG - TRANSIENT EVENT AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 485 TI0000SW Total Loss of Service Water ACAAS0_50A FLAG - OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Trp ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B DGIANOTRUN FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DGI BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 18 AND 17 NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run SWTODG TAG - SW Lost to DG (cooling)
TRANSX TAG - TRANSIENT EVENT AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 486 TI0000SW Total Loss of Service Water ACAASW050A FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of Aln Off-Site Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B DGlANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DG1BNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SWIFIRE WATER SUCTION (INITIATOR)
SWTODG TAG - SW Lost to DG (cooling)
TRANSX TAG - TRANSIENT EVENT AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 487 TI000OSW Total Loss of Service Water ACAASOWWA FLAG - OFFSITE POWER MODE 50150 ALT (CKT 751 TO BUS 126, CKT 767 TO BUS I2A)
ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B DGIARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCCIPUMPSR Common Cause Failure Of Service Water Pumps To Run SWTODOG TAG - SW Lost to DG (cooling)
TRANSX TAG - TRANSIENT EVENT AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 488 TI0000SW Total Loss of Service Water ACAA5050A FLAG-OFFSITE POWER MODE 50/50 ALT (CKT 751 TO BUS 12B, CKT 767 TO BUS 12A)
ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of APl Off-She Power Following Reactor Trip ACTRAINA TAG - Failure ofAC Train A ACTRAINB TAG - Failure of AC Train B DGIARUN FLAG - DG A IS RUNNING AND TIED TO BUSES 14 AND 18 DGIBNOTRUN FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 DGAZRUNDGA DG A TRIPS FOLLOWING AN SI OR LOOP EVENT GIVEN THAT IT WAS RUNNING AN TIED TO BUS NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
SWTODG TAG - SW Lost to DG (cooling)
TRANSX TAG - TRANSIENT EVENT AAAA FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS 489 TI0000SW Total Loss of Service Water ACAA50._50N FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 787 TO BUS 12B)
ACAZDLOSP1 Failure to Restore Offsite Power Wthin 1 Hour ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP ACLOPRTALL Loss of All Off-Site Power Following Reactor Trip ACTRAINA TAG - Failure of AC Train A ACTRAINB TAG - Failure of AC Train B DGIANOTRUN FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 DGIBNOTRUN FLAG - DG O
IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SBO TAG - STATION BLACKOUT SEQUENCE SWCCIPUMPSR Common Cause Fahure Of Service Water Pumps To Run SWTODG TAG - SW Lost to DO (cooling)
AAAA FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS 490 TIOOOSW Total Loss of Service Water ACAASOW50N FLAG - OFFSrTE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
ACAZDLOSPI Failure to Restore ffshte Power Within 1 Hour ACLOPNOSI2 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP 0.83 8.25E-01 0.5 5.001-01 2.110-03 2.10E-03 1 1.00E+05 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.78E-01 0.42 4.21E-01 0.58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.05 4.556-02 0.04 3.56E-02 1 1.00E+00 1 1.006+00 0 O.00E+00 1 1.00E+00 O.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 6.97E-01 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.02 2.47E-02 0.02 2.476-02 0.03 3.13E-02 0.04 3.56E-02 1 1.00E-00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.002+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+50 1 1.006+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 15.001+00 1 1.00E+00 5 0.00E+00 1 1.00E+00 O.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1 006E+0 0.88 8.76E-01 1.00E-04 1.006-04 1 1.006+00 1 1.00E600 0 0.00E+00 I 1.00E+00 5.00E+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.002+00 1 1.00E+00 0.03 3.00E-02 1 9.976-01 0.1 1.00E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 1 1.006+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 5.006+00 0.83 8.25E-01 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.03 3.00E-02 1 9.97E-01 0.1 1.00E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00E-04 1 1.00E+00 1 1.00E+00 0 0.006+00 1 1.05E+00 0.00E+00 0.02 1.70E-02 0.38 3.81E-01 0.5 5.00E-01 2.11012-03 2.10E-03 1 11.00E+00 1 1.00E+00 1 9.97E-01 1 9.9712-01 1 1.00E+00 0.88 1.76E-01 I 1.00E+00 1.21E-04 1.2112-04 I 1.00E+00 00O.OOE+O0 1 1.0012+00 0.0OE+00 0.02 1.70E-02 0.38 3.81E-01 0.5 5.006-01
ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DGIBNOTRUN NOSBO PCIF SBO SWCXXSUCTI SWTODG WAA 491 T10000SW ACAASO50N ACB2FIBS17 ACLOPNOSI2 ACLOPRTALL.
ACTRAINA ACTRAINB DGJANOTRUN DG1 BNOTRUN NOSBO PCF SWTMPUMPIA SWTMPUMPIC SWTODG TRANSX AAAA 492 T10000SW ACAASO_SON ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DGIANOTRUN DG1 BNOTRUN NOSBO PCF SBO SWCCIPUMPSR SWTODG AAAA 493 T10000SW ACAAS0_50N ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB AFAZFAILXX DG1ANOTRUN DG1BNOTRUN NOSBO PCF SBO SWCXXSUCTI SWTODG AAAA 494 T10000SW ACAASO_50N ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DGIANOTRUN DG1 BNOTRUN NOSBO PCF SWCCIPUMPSR SWTODG TRANSX AAAA 495 T10000SW ACAASOL60N ACLOPNOSI2 ACLOPRTALL ACTRAINA ACTRAINB DG1ANOTRUN DGI1NOTRUN NOSBO PCF SWCXXSUCTI SWTODG TRANSX AAAA 496 TI0000SW ACB2FIBSI7 ACB2FISS18 ACTRAINA ACTRAINB AXHFDSAFWX DGAAINTAKE FSAZCORRO3 NOSBO PCIF SWAZINTAKE TRANSX AAAA 497 T10000SW ACB2FIBS17 ACB2FIBS18 ACTRAINA ACTRAINB AXXVN09728 DGAAINTAKE NOSBO PCF SWAZINTAKE TRANSX AAAA 498 T10000SW ACB2FISS17 ACB2FTBS1B ACTRAINA Loss of AN Off-She Power Following Reactor Trip TAG - Falure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND IS FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION INITIATOR)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/60 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B)
Local Fault on 480 VAC Bus 17 CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-She Power Follow/ng Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - 00 IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C In maintenance TAG - SW Lost to DG (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of Al Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (Independent of AF300)
FLAG - DG; A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG 8 IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to DG (cooling)
FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE W0/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AN Off-She Power Following Reactor Trip TAG - Failul of AC Train A TAG - Failure of AC Train B Non-Elec Failure of all MDAFW pumps (independent of AF300)
FLAG - DG 1A IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - STATION BLACKOUT SEQUENCE TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A, CKT 767 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of AlM Off-She Power Following Reactor Trip TAG - Failure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG - DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Common Cause Failure Of Service Water Pumps To Run TAG - SW Lost to D0 (cooling)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water FLAG - OFFSITE POWER MODE 50/50 NORMAL (CKT 751 TO BUS 12A. CKT 767 TO BUS 12B)
CORRECTION FACTOR FOR NO SI CONDITION FOR LOOP Loss of All Off-Site Power Following Reactor Top TAG - Fallure of AC Train A TAG - Failure of AC Train B FLAG - DG IA IS NOT RUNNING AND TIED TO BUSES 14 AND 18 FLAG. DG B IS NOT RUNNING AND TIED ONTO BUSES 16 AND 17 TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 1i TAG - Failure of AC Train A TAG - Failure of AC Train B Operators Fail to Correctly Align SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED Correction Factor for Operators Failing to align SAFW duoe to increased stress during loss of SIN to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Assumption that Lake Temperature Is Cold Enough to Cause FrazIl Ice and Loss of SW (32/2052 hrs)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A TAG - Failure of AC Train B 3 way vafee 9726 fails to operate FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENERGIZED TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Assumption that Lake Temperature Is Cold Enough to Cause Frazit Ice and Loss of SW (32/2052 hrs)
TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A 2.10E-03 2.10E-03 I 1.00E-00 1 1.00E+00 I 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.00E-04 1.00E-04 1 1.00E+00 O 0.00E+00 I 1.00E+00 0.00E+00 0.02 1.70E-02 1.01E-06 1 6.85-E03 0.5 5.00E-01 2.10E-03 2.10-E03 1 1.008+00 1 1.00E+00 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.768-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 0.02 1.70E-02 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.1 1.00E-01 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 1.21E-04 1.21E-04 I 1.00EO00 0 0.00E+00 1 1.00E+00 0.00E+00 0.02 1.70E-02 0.5 5.00E-01 2.10E-03 2.10E-03 1 1.00E+00 1 1.00E+00 0.1 1.008-01 1 9.97E-01 1 9.97E-01 1 1.00E+00 0.88 8.76E-01 1 1.008+00 1.00E-04 1.00E-04 I 1.00E+00 0 0.008+00 1 1.00E+00 0.00E+00 0.02 1.70E-02 0.5 8.00E-01 2.10E-03 2.10E-03 I
1.00E+00 1 1.00E+00 1
9.97E-01 1
9.97E-01 1 1.00E+00 0.88 8.76E-01 1.21E-04 1.21E-04 I 1.00E+00 1 1.008+00 0 0.00E+00 1 1.008+00 0.00E+00 0.02 1.70E-02 0.5 5.00E-01 2.10E-03 2.1OE-03 1 1.00E+00 1 1.00E+00 1 9.97E-01 1 6.97E-01 1 1.00E+00 0.88 8.76E-01 1.00E-04 1.00-E04 1 1.00E+00 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.008+00 1.01E-06 1 8.85E-03 1.01E80 I 8&85E-03 1 1.00E+00 1 1.00E+00 5.18E-03 5.19E-03 0.12 1.23E-01 1 1.93E+00 1 1.008+00 0.88 8.76E-01 0.02 1.66E-02 1 1.008+00 0 0.00E+00 1 1.00E+00 0.00E+00 1.0181-06 1 8.85E-03 1.01E-06 1 8.65E-03 1 1.00E+00 I 1.00E+00 1.00E-03 1 1.00E-03 0.12 1.23E-01 1 1.008+00 0.88 8.76E-01 0.02 1.66E-02 1 1.00E+00 0 0.008+00 1 1.00E+00 O.00E+00 1.01E-08 1 8.85E-03 1.011-08 72 7.27E-05 1 1.00E+00
ACTRAINB AXHFDSAFWX FSAZCORRO3 NOSBO PCF TRANSX AAAA 499 T10000SW ACB2FISS17 ACB2FTBS18 ACTRAINA ACTRAINB AXMMSAFWPC AXMMSAFWPD NOSBO PCF TRANSX AAAA 500 T10000SW ACB2FIBSI7 ACB2FTBS18 ACTRAINA ACTRAINB AXTMSAFSGA AXTMSAFSGB NOSBO PCF TRANSX AAAA 501 TIO000SW ACB2FIBS17 ACB2FTBS18 ACTRAINA ACTRAINB A)0CVN09728 NOSBO PCF TRANSX AAAA 502 T10000SW ACB2FIBSI7 ACB2FTBSI8 ACTRAINA ACTRAINB NOSBO PCF RCAZDD0515N RCHFDPLOCA RCRZT0431C SLO TLSTRANS AAAA 503 T10000SW ACB2FIBS17 ACB2FTBS18 ACTRAINA ACTRAINB NOSBO PCF RCAZD00516N RCHFDPLOCA RCRZT00430 SLO TLSTRANS AMAA 504 T10000SW ACB2FIBS17 ACTRAINS AXCCDMOVNB NOSBO PCF SWTMPUMP1A SWTMPUMPIC TRANSX 505 T10000SW ACB2FIBS17 ACTRAINB AXCCFSAFWA NOSBO PCF SWTMPUMP1A SWTMPUMP1C TRANSX 506 TI0000SW AC62FIBS17 ACTRAINS AXCCSSAFWA NOSBO PCF SWTMPUMP1A SWTMPUMP1C TRANSX 507 TI10000SW ACB2FIBS17 ACTRAINB AXHFOSAFWX FSAZCORRO3 NOSBO PCF SWTMPUMPIA SWTMPUMPIC TRANSX 508 TI0000WS ACB2FIBSI7 ACTRAINS AXHFLSAFWA AXMMSAFWPD NOSBO PCF SWTMPUMP1A SWTMPUMPIC TRANSX 509 T10000SW ACB2FIBS17 TAG - Failure of AC Train s Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress dudng loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fauot on 480 VAC Bus 17 Local Fault on 480 VAC Bus 19 TAG - Failure of AC Train A TAG - Failure of AC Train B Failure of SAFW Pump 1C train Failure of SAFW Pump 1D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A TAG - Failure of AC Train B SAFW TRAIN C TO SIG A O.O.S. DUE TO TIM SAFWTRAIN D TO SIG 8 OO.S. DUE TO TIM TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A TAG - Failure of AC Train B 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Servce Water Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Cinsed Due to PORV Leakage Operators Fail To Close PORV Block Valve (515/5156) To Terminate LOCA W/In 3 Min PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TAG - TRANSIENT INDUCED SMAlJL LOCA SEQUENCES FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Sernvce Water Local Fault on 480 VAC Bus 17 Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage Operators Fail To Close PORV BElck Valve (515/516) To Terminate LOCA W/In 3 Min PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Common cause failure of MOVs 9701A and 9701B to thmttle flow TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Common cause failure of SAFW Pumps 1C and ID to ton TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Common cause failure of SAFW Pumps 1C and tO to start TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Operators Fat to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Failure to restore SAFW Pump Train 1C to service post test/maint Failure of SAFW Pump 1D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 1 1.001+00 5.19E-03 5.1SE-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 0 0.00E+00 I 1.00E+00 0.OOE+00 1.01 E-06 1 8.851-03 1.011-06 72 7.27E-05 1 1.00E+00 1 1.00E+00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1 t.00E+00 O 0.00E+00 1 1.00E+00 O0OE00 1.01E-06 1 8.85M-O3 1t01SE-O 72 7.275-05 1 1.001+00 1 1.006E00 0.02 1.67E-02 0.01 1.49E-02 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 O 0.00+E00 1 1.00E+00 0.00E+00 1.01E-00 1 8.85E-03 1.01E-06 72 7.27E-05 1 1.00E+00 1 1.00E+00 1.0E-03 1 I1.00E-03 I 1.OOE+00 0.88 8.76E-01 1 1.00E+00 0 0.00E+00 1 1.00E+00 0,00E+00 1.01E-06 1 8.85E-03 1.01E-06 72 7.27E-05 1 1.00E+00 1 1.005+00 1 1.00E+00 0.88 8.76E-01 0.97 9.87E-01 0.0 5.00E-02 5.00E-03 1 5.00E-03 1 1.005+00 1 1.005+00 0 0.00E+00 1 1.00E+00 0.00E+00 1.01E-06 1 8.85E-03 1.01E-06 72 7.27E-05 1 1.00E+00 1 1.00E+00 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.O0E-O3 1
5.00E-03 1 1.00E+00 I 1.00E+00 0 0.00E+00 1 1.005+00 0.00E+00 1.01E-06 1 8.85E-03 1 1.005+00 7.28E-05 7.28E-05 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 I 1.00E+00 I 1.00E+00 0O00E+80 1.01E-06 1 8.85E-03 1 1.00E+00 1.99E-05 1.99E-05 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.05E+00 1 1.00E+00 0.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 8.79E-05 8.79E-05 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.58E-02 1 1 00E+00 1 1.00E+00 0.00E+00 1.01E-06 1 8.85E-03 1 1.005E+8 5.19E-03 5.195-03 1 1.93E+00 1 1.00E+80 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.005+00 0.00E+00 1.01E-08 1 8.85E-03 1 1.00E+00 3.00E-03 3.00E-03 0.02 2.29E-02 1 1.00E+00 0.88 9.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.005+00 I 1.00E500 0.OOE+00 1.01 E-06 1 8.85E-03
ACTRAINB AXHFLSAFWA AXTMSAFSGB NOSBO PCF SWTMPUMPlA SWTMPUMPIC TRANSX 510 T1000OSW ACB2FIBS17 ACTRAINB AXHFLSAFWB AXMMSAFWPC NOSBO PFP SWTMPUMP1A SWTMPUMPIC TRANSX 511 T10000SW ACB2FIBS17 ACTRAINB AXHFLSAFWB AXTMSAFSGA NOSBO PCF SWTMPUMPIA SWTMPUMPIC TRANSX 512 T10000SW ACB2FIBS17 ACTRAINB AXMMSAFWPC AXMMSAFWPD NOSBO PCF SWTMPUMPIA SWTMPUMPIC TRANSX 513 T10000SW ACB2FIBS17 ACTRAINB AXTMSAFSGA AXTMSAFSGB NOSBO PCF SWTMPUMP1A SWTMPUM P1C TRANSX 514 T10000SW ACS2FIBSI7 ACTRAINB AXXVN09728 NOSBO PCF SWrMPUMP1A SWTMPUMPIC TRANSX 515 TI7000SW ACB2FIBS17 ACTRAINB FSTMFCITYW NOSBO PCF SWTMPUMPIA SWTMPUMPIC TRANSX 516 T10000SW ACB2FIBS17 ACTRAINB NOSBO PCF RCAZD00515N RCHFDPLOCA RCRZT0431C SLO SWTMPUMPIA SWTMPUMPIC TLSTRANS 517 T7000SW ACB2FIBS17 ACTRAINB NOSBO PCF RCAZD00516N RCHFDPLOCA RCRZT00430 SLO SWTMPUMPIA SWTMPUMPIC TLSTRANS 518 TI000OSW ACB2FIBS18 ACB2FTSS17 ACTRAINA ACTRAINB AXHFDSAFWX FSAZCORR03 NOSBO PCF TRANSX AAAA 519 T10000SW ACS2FIBS1 8 ACB2FTBS17 ACTRAINA ACTRAINB AXMMSAFWPC AXMMSAFWPD NOSBO PCF TRANSX AAAA 520 TI0000SW ACB2FIBS18 TAG - Failure of AC Train B Failure In restore SAFW Pump Train 1C to service post test/maiot SAIWTRAIN D TO S/G B O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG. Failure of AC Train B Failure to restore SAFW Pump Train 10 to service post test/maint Failure of SAFW Pump IC train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A In maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Failure to restore SAFW Pump Train 1D to service post test/maint SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B Failure of SAFW Pump IC train Failure of SAFW Pump ID Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump Ain maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B SAFW TRAIN C TO S/G A O.O.S. DUE TO TIM SAFW TRAIN D TO S/G B O.O.S. DUE TO TIM TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B 3 way valve 9728 fails Io operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B City Water Supply to Yard Fire Loop Inoperable TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump A In maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Operators Fag To Close PORV Block Valve (515/516) To Terminate LOCA W/In 3 Min PORV PCV-431C Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE SW Pump A in maintenance SW Pump C in maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Opereted VaNe 516 Is Not Closed Due To PORV Leakage Operators Fall To Close PORV Block Valve (515&158) To Terminate LOCA W/In 3 Min PORV PCV-430 Fails To Reseat After Steam ReFlef TAG - SMALL LOCA SEQUENCE SW Pump A In maintenance SW Pump C in maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train A TAG - Failure of AC Train B Operators Fail to Correctly Align SAFW (Cormected for TI0000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train A TAG - Failure of AC Train B Failure of SAFW Pump 1C train Fature ofSAFW Pump lD Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 16 1 1.OOE+00 3.00E-03 3.OOE-03 0.01 1.40E-02 1 1.OOE+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 I 1.00E+00 0.00E+00 1.01E-06 I
8.85E-03 1 1.00E+00 3.00E-03 3.SOE-03 0.02 2.29E-02 1 1.002+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-06 I 8.85E-03 1 1.00E+00 3.00E-03 3.00E-03 0.02 1.67E-02 I 1.00E÷00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.01 E-06 1 8.85E-03 1 1.00+E00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.78E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 O.00E+00 1.01E-06 1 8.S5E-03 1 1.00E+00 0.02 1.67E-02 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 0.03 3.13E-02 0.04 3.56E.-02 1 1.00E+00 1 1.OOE+00 O.00E+00 1.011-06 1 8.85E-03 I 1.00E+00 l.OGE-03 1 1.00E-03 1 1.00E+00 0.88 8.78E-01 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-0 1 8.85E-03 1 1.00E+00 4.22E-05 4.22E-05 I 1.00E+00 0.88 8.76E-01 0.0 3.113E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-08 1 8.8E-03 1 1.OOE+00 1 1.OOE+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 1 1.0OE+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-O6 I 8.85E-03 I 1.00E+00 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 1 1.008+00 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-OB 1
M.85E-03 1.01E-06 72 7.27E-05 1 1.00E+00 1 1.00E+00 5.19E-03 5.18E-03 I 1.93E+00 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 0 0.00E+00 1 1.00E+00 0.00E+00 1.01E-06 0 8.85E-03 1.011E-08 72 7.27E-05 I 1.OOE+00 1 1.00E+00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 1 1.00E+00 0 0.00E+00 1 1.00E+00 O.OOE+00 1.01E-0 1 8.8E-03
ACB2FTBS17 ACTRAINA ACTRAINB AXTMSAFSGA AXTMSAFSGB NOSBO PCF TRANSX AAAA 521 TIOO00SW ACB2FIBS18 ACB2FTBS17 ACTRAINA ACTRAINB A)OCVN09728 NOSBO PCF TRANSX AAAA 522 TI0O0OSW ACB2FIBSIS ACB2FTBS17 ACTRAINA ACTRAINB NOSBO PCF RCAZD00515N RCHFDPLOCA RCRZT0431C SLO TLSTRANS AAAA 523 T10000SW ACB2FIBS18 ACB2FTBS17 ACTRAINA ACTRAINB NOSBO PCF RCAZD00516N RCHFOPLOCA RCRZT00430 SLO TLSTRANS AAAA 524 TIO0000W ACB2FIBS18 ACTRAINA AXCCDMOVNB NOSBO PCF SWTMPUMP1B SWTMPUMP1D TRANSX 525 TI0000SW ACB2FIBSS18 ACTRAINA AXCCSSAFWA NOSBO PCF SWTMPUMP1B SWTMPUMPID TRANSX 528 TI00OOSW ACB2FIBS18 ACTRAINA AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWTMPUMPIB SWTMPUMPI D TRANSX 527 TIO00SW ACB2FIBS18 ACTRAINA AXHFLSAFWA AXMMSAFWPD NOSBO PCF SWTMPUMPIB SWTMPUMP1D TRANSX 528 TIOOOOSW ACB2FIBS18 ACTRAINA AXHFLSAFWA AXTMSAFSGB NOSSO PCF SWTMPUMP1B SWTMPUMP1D TRANSX 529 TI0000SW ACB2FIBS18 ACTRAINA AXHFLSAFWB AXMMSAFWPC NOSBO PCF SWTMPUMP1B SWTMPUMP1D TRANSX 530 T10000SW ACB2FIBS18 ACTRAINA AXHFLSAFWB AXTMSAFSGA NOSBO PCF SWTMPUMPI B SWTMPUMP1D TRANSX 531 TI0000SW Local Fault on 480 VAC Bus 17 TAG - Faluro of AC Train A TAG - Failure of AC Train B SAFWTRAIN C TO S/G A O.O.S. DUE TO T/M SAFWTRAIN D TO S/G B O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train A TAG - Failore of AC Train B 3 way value 9728 falls to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR TAG - TRANSIENT EVENT FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Senrce Water Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Operators Fail To Close PORV Block Value (515/518) To Terminate LOCA W/tn 3 Min PORV PCV-431C Fails To Reseal After Steam Relief TAG - SMALL LOCA SEQUENCE TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES FACTOR TO ELIMINATE UV AND ILLOGICAL CUTSETS Total Loss of Service Water Local Fault on 480 VAC Bus 18 Local Fault on 480 VAC Bus 17 TAG - Failure of AC Train A TAG - Failure of AC Train B TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Due To PORV Leakage Operators Fail To Close PORV Block Value (515/516) To Terminate LOCA WfIn 3 Min PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE TAG -TRANSIENT INDUCED SMALL LOCA SEQUENCES FACTOR TO ELIMINATE UVAND ILLOGICAL CUTSETS Total Loss of Senrice Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Common cause failure of MOVs 9701A and 97018 to throttle flow TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Senrice Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Common cause failure of SAFW Pumps 1C and 1 D to start TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Operators Fail to Correctly Align MAFW (Corrdeed for T10000SW and Some Fire Events For Stress)
Correctlon Factor for Operators Failing to arlgn SAFW duoe to increased stress during los of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Faillow of AC Train A Failure to restore FW Pump Train 1C to service post tlsllmaint Failure of SAFW Pump 1D Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Falurl oo nrstore SAFW Pump Train iC to service post test/maint SAFW TRAIN D TO S/G 8 O1O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus I8 TAG - Failure Of AC Train A Failure to retore SAFW Pump Train ID to service post tlst/maint Failure of SAFW Pump IC train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local FauSt on 480 VAC Bus tI TAG - Falure ofAC Train A Failure to restore SAFW Pump Train ID to service pest test/maint SAFW TRAIN C TO S/G A O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water 1.01 E-06 72 7.27E-05 I 1.00E-00 1 1.ooE+00 0.02 1.67E-02 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 I i.00E+s0 0 0.00E+00 1 1.0012+
0.00E+00 1.01E-06 I 8.85E-03 1.01E-06 72 7.27E-05 I 1.00El00 1 1.00E+00 1.00E-03 1 1.00E-03 I 1.00E+00 0.88 8.76E-01 1 1.008+00 o 0.50E+00 1 1.00E+00 0.00E+00 1.01E-06 1 8.85E-03 1.01E-06 72 7.27E-05 1 1.00E+00 1 1.08E+00 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.008-02 5.00E-03 I 5.00E-03 1 1.00E+00 I 1.000E+0 0 0.08E+00 I 1.00E+00
.O00E+00 1.01E-06 1 8.85E-03 1.01E-08 72 7.27E-05 1 1.00E-00 1 1.00E+00 1 1.00E+00 0.88 8.78E-01 0.97 9.678-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 1 1.00E+00 1 1.001+00 0 0.00E+00 1 1.00E+00 0.00E+00 1.01E-08 1 8.85E-03 1 1.00E+00 7.28E-05 7.28E-05 1 1.00E+00 0.88 8.76E-01 0.05 4.85E-02 7.18E-03 7.15E-03 1 1.001+00 1 1.00E+00 0.00E+00 1.018-06 1 8.85E-03 1 1.00E+00 8.79E-05 8.79E-05 1 1.00E+00 0.88 8.78E-01 0.05 4.55E-02 7.15E-03 7.15E-O3 1 1.008+00 1 1.00E+00 O.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 5.19E-03 5.19E-03 I 1.93E+00 1 1.008+00 0.88 8.76E-01 0.05 4.55E-02 7.151-03 7.16E-03 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-06 1 8.85E-03 1 1.008+00 3.00E-03 3.00E-03 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.15E-OS 7.15E-03 1 1.00E+00 1 1.008+00 0.00E+00 1.01E-08 I 8.85E-03 1 1.00E+00 3.008-O3 3.00E-03 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 I 1.00E+00 0.008+00 1.01E-08 1 8.85E-03 1 1.00E+00 3.00E-03 3.00E-03 0.02 2.29E-02 1 1.00E+00 0.88 8.78E-01 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+80 0.00E+00 1.01E-00 I 8.85E-03 1 1.00E+00 3.00E-03 3.00E-03 0.02 1.67E-02 1 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.15E-03 7.15E-03 I
1.00E+00 I 1.00E+00 0.00E+00
ACB2FIBS18 ACTRAINA AXMMSAFWPC AXMMSAFWPD NOSBO PCF SWTMPUMPIB SWTMPUMPID TRANSX 532 TIOOCOOW ACB2FIBS1S ACTRAINA AXTMSAFSGA AXTMSAFSGB NOSBO PCF SWTMPUMPIB SWTMPUMPID TRANSX 533 T10000SW ACB2FIBS1S ACTRAINA AXMVN09728 NOSBO PCF SWTMPUMPI B SWTMPUMPID TRANSX 534 TI0000SW ACB2FIBSIB ACTRAINA FSTMFCITYW NOSBO PCF SWTMPUMPIB SWTMPUMPID TRANSX 535 TI0000SW ACB2FIBS18 ACTRAINA NOSBO PCF RCAZD00515N RCHFDPLOCA RCRZT0431C SLO SWTMPUMP1I SWTMPUMP1D TLSTRANS 536 TIOOOOSW ACB2FIBS18 ACTRAINA NOSBO PCF RCAZDO0516N RCHFDPLOCA RCRZT00430 SLO SWTMPUMPIB SWTMPUMP1D TLSTRANS 537 TIOOOStW AXHFDSAFWX FSAZCORR03 NOSSO PCF SWAASWPIANR SWAASWPICNR SWCCPUMPSS SWTMPUMP1A SWTMPUMPIC TRANSX 538 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1ANR SWAASWPICNR SWMMOSWPDS SWTMPUMPIA SWTMPUMP1B SWTMPUMP1C TRANSX 539 TISOCOOW AXHFDSAFWX FSAZCORR03 NOSBO PCF SWAASWPIANR SWAASWPICNR SWTMPUMPIA SWTMPUMPIB SWTMPUMP1C SWTMPUMPI D TRANSX 540 T10000SW AXHFDSAFWX FSAZCORR03 NOSBO POF SWAASWP1ANR SWAASWPICR SWMMOSWPDS SWMMSWPCRI SWTMPUMPIA SWTMPUMPI B TRANSX 541 T10000SW AXHFDSAFWX FSAZCORR03 NOSBO PCF SWAASWPIANR Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A Failure of MEW Pump 1C train Failure of SAFW Pump ID Train TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A SAFWTRAIN C TO S/G A O.O.S. DUE TO T/M SAFW TRAIN D TO SIG B O.O.S. DUE TO T/M TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A 3 way valve 9728 fails to operate TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump Bin maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A City Water Supply to Yard Fire Loop Inoperable TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Local Fault on 480 VAC Bus tS TAG - Failure of AC Train A TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 515 Is Not Closed Due to PORV Leakage Operators Fail To Close PORV Block Valve (5151516) To Terminate LOCA WAn 3 Min PORV PCV-431C Fails To Reseal After Steam Relief TAG - SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Local Fault on 480 VAC Bus 18 TAG - Failure of AC Train A TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR Motor-Operated Valve 516 Is Not Closed Duo To PORV Leakage Operators Fail To Close PORV Block Valve (5151518) To Terminate LOCA WIlIn 3 Min PORV PCV-430 Fails To Reseat After Steam Relief TAG - SMALL LOCA SEQUENCE SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT INDUCED SMALL LOCA SEQUENCES Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for TI000OSW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress duling loss ofSWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWO1A Is Not In Operation FLAG - Service Water Pump PSW01C Is Not In Operation Common Cause Failure Of Service Water Pumps To Start SW Pump A In maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for TISOO0SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWOIA Is Not In Operation FLAG - Service Water Pump PSWO1C Is Not In Operation FAILURES OF SW PUMP D TO START SW Pump A in maintenance SW Pump B in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for TIO0OOSW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss ofSWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWO1A Is Not In Operation FLAG - Service Water Pump PSW01C Is Not In Operation SW Pump A In maintenance SW Pump B in maintenance SW Pump C in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWOIA Is Not In Operation FLAG - Service Water Pump PSW0IC Is In Operation FAILURES OF SW PUMP D TO START FAILURES OF SW PUMP C TO RUN SW Pump A in maintenance SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for TIOO0SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01A Is Not In Operation 1.01E-06 1 8.85E-03 I 1.00E+00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.1$E-03 tf.15E-03 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-06 1 8.85E-03 1 1.00E+00 0.02 1.67E-02 0.01 1.48E-02 1 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 0.00E+00 tO0E-06 1 8.85E-03 1 1.00E+00 1.00E-03 1 1.00E-03 1 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.15E-03 7.158-03 1 1.00E+00 1 1.00E+00 0.00E+00 1.01E-OG I 8.lE-03 1 1.00E+00 4.22E-05 4.22E-05 1 1.00E+00 0.88 8.76E-01 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 I 1.00E+00 0.08E+00 1.018-00 1 8.85E-03 I 1.00E+00 I 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 1 1.00E+00 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 O.00E+00 1.01E-O 1 8.85E-03 1 1.00E+00 1 1.00E+00 0.88 8.76E-01 0.97 9.67E-01 0.05 5.00E-02 5.00E-03 1 5.00E-03 1 1.0OE+00 0.05 4.55E-02 7.15E-03 7.151-03 1 1.00E+00 1 1.00E+00 0.00E+00 5.15E-03 5.18E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.42 4.21E-01 1.14E-04 1.14E-04 0.03 3.13E-02 0.04 3.50E-02 1 1.00E+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.42 4.21E-01 3.28E-03 3.28E-03 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03 I 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.42 4.21E-01 0.03 3.13E-02 0.05 4.55E-02
.0,4 3.56E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 O.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.53 5.79E-01 3.28E-03 3.28E-03 0.02 2.47E-02 0.03 3.13E-02 0.05 4.5512o02 I 1.00E+00 I 1.00E+00 0.00E+00 5.19E-03 5.1912-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01
SWAASWPICR SWMMSWPCRI SWTMPUMPIA SWTMPUMPIB SWTMPUMP1D TRANSX 542 710000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1AR SWAASWPtCNR SWMMSWPARI SWTMPUMPI B SWfMPUMPiC SWIMPUMPID TRANSX 543 710000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1AR SWAASWP1CR SWMMSWPARI SWMMSWPCRI SWTMPUMPIB SWTMPUMPID TRANSX 544 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWPIAR SWMMSWPARI SWPPJIHDRB SWTMPUMP1B SWTMPUMPID TRANSX 545 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1BNR SWAASWP1DNR SWTMPUMPIA SWTMPUMP1B SWTMPUMP1C SWTMPUMP1D TRANSX 545 7100006W AXHFOSAFWX FSAZCORR03 NOSBO PCF SWAASWPIBNR SWAASWPIDR SWMMOSWPCS SWMMSWPDRI SWTMPUMPIA SWTMPUMPI B TRANSX 547 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWP1BNR SWAASWP1DR SWMMSWPDRI SWTMPUMP1A SWTMPUMP1B SWTMPUMP1C TRANSX 548 TI0000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWPIBNR SWPPJIHDRB SWTMPUMPIA SWTMPUMPI B SWTMPUMPIC TRANSX 549 T10000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWPIBR SWAASWP1DNR SWMMSWPBRI SWTMPUMP1A SWTMPUMP1C SWTMPUMP1D TRANSX 550 TI0000SW AXHFDSAFWX FSAZCORRO3 NOSBO PCF SWAASWPI BR SWAASWP1 DR SWMMSWPBRI SWMMSWPDRI SWTMPUMP1A SWTMPUMP1C TRANSX 551 TI70SW AXHFDSAFWX FLAG - Service Water Pump PSW01C Is In Operation FAILURES OF SW PUMP C TO RUN SW Pump A in maintenance SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Courected for TI0000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01A Is In Operation FLAG - Service Water Pump PSW01C Is Not In Operation FAILURES OF SERVICE WATER PUMP A TO RUN SW Pump B in maintenance SW Pump C In maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Conrection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Serice Water Pump PSW01A Is In Operation FLAG - Service Water Pump PSW01C Is In Operation FAILURES OF SERVICE WATER PUMP A TO RUN FAILURES OF SW PUMP C TO RUN SW Pump B in maintenance SW Pump D In maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Falling to align SAFW due to Increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01A Is In Operation FAILURES OF SERVICE WATER PUMP A TO RUN SERVICE WATER HEADER "B" PIPING RUPTURE SW Pump B in maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01B Is Not In Operation FLAG - Service Water Pump PSWOrID Is Not In Operation SW Pump A In maintenance SW Pump B in maintenance SW Pump C In maintenance SW Pump D in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAPW due to increased stress during loss of SWto TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW01B Is Not In Operation FLAG - Service Water Pump PSW01D Is In Operation FAILURES OF SW PUMP C TO START FAILURES OF SW PUMP D TO RUN SW Pump A in maintenance SW Pump B in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Algn SAFW (Corrected for TI0000SW and Some Fire Events For Stress)
Conrrection Factor for Operators Failing to align SAFW due to increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWO1B Is Not In Operation FLAG - Service Water Pump PSWO1D Is In Operation FAILURES OF SW PUMP D TO RUN SW Pump A ln maintenance SW Pump B In maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Correctly Align SAFW (Conrected for TI0000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due Io increased stress during ioss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW0 B Is Not In Operation SERVICE WATER HEADER WB*
PIPING RUPTURE SW Pump A in maintenance SW Pump B in maintenance SW Pump C in maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operatom Fail to Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Correction Factor for Operators Failing to align SAFW due to Increased strss during loss ofSWfo TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSWM1B Is In Operation FLAG - Service Water Pump PSWOID Is Not In Operation FAILURES OF SW PUMP B TO RUN SW Pump A in maintenance SW Pump C in maintenance SW Pump Din maintenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail Io Correctly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress)
Conrection Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to TAG - NO STATION BLACKOUT PLANT CAPACITY FACTOR FLAG - Service Water Pump PSW018 Is In Operation FLAG - Service Water Pump PSWO1D Is In Operation FAILURES OF SW PUMP B TO RUN FAILURES OF SW PUMP D TO RUN SW Pump A In maintenance Sw Pump C in matntenance TAG - TRANSIENT EVENT Total Loss of Service Water Operators Fail to Conectly Align SAFW (Corrected for T10000SW and Some Fire Events For Stress) 0g58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.00 4.55E-02 7.ISE-03 7.15E-03 1 1.00E+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.42 4.21E-01 0.02 2.47E-02 0.05 4.55E-02 0.04 3.56E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 0.00E-00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.02 2.47E-02 0.02 2.47E-02 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.78E-01 0.58 5.79E-01 0.02 2.47E-02 5.53E-07 1 4.94E-03 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03 I 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.42 4.21 E-01 0.03 3.13E-02 0.00 4.55E-02 0.04 3.56E-02 7.15E-03 7.15E-03 1 1.00E+00 I 1.00E+00 0.00E+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 3.28E-03 3.28E-03 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 1 1.00E+00 1 1.00E+00 0.000+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.001+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.000+00 5.19E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0.88 &.78E-01 0.42 4.21E-01 5.53E-07 I
4.84E-03 0.03 3.13E-02 0.05 4.550-02 0.04 3.56E-02 1 1.00E+00 1 1.00E0+0 O.00+E00 5.19E-03 5.19E-03 1 1.93E+00 1 1.000+00 0.88 8.76E-01 0.58 5.79E-01 0.42 4.21E-01 0.02 2.47E-02 0.03 3.13E-02 0.04 3.56E-02 7.15E-03 7.15E-03 1 1.001+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03 I 1.93E+00 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.02 2.47E-02 0.02 2.47E-02 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03
FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to Increased stress durtng loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance TRANSX TAG - TRANSIENT EVENT 552 TIO000SW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TISOOOSW and Some Fire Events For Stress)
FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to Increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C In maintenance SWrMPUMP1D SW Pump D in maintenance TRANSX TAG - TRANSIENT EVENT 553 TI000OSW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected forTI0000SW and Some Fire Events For Stress)
FSAZCORRO3 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SW to NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE SWTMPUMPIB SW Pump 8 In maintenance SWTMPUMPID SW Pump D in maintenance TRANSX TAG - TRANSIENT EVENT 554 T1000OSW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corected for 1I0000SW and Some Fire Events For Stress)
FSAZCORR03 Correction Factor for Operators Faeling to align SAFW due to iseneed stress duoing los ofSWto NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE SWIMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance TRANSX TAG - TRANSIENT EVENT 555 TI0000SW Total Loss of Service Water AXHFDSAFWX Operators Fail to Correctly Align SAFW (Corrected for TIOOOOSW and Some Fire Events For Stress)
FSAZCORR03 Correction Factor for Operators Failing to align SAFW due to increased stress during loss of SEWto NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER 'B" PIPING RUPTURE SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance TRANSX TAG - TRANSIENT EVENT
&%e TS00OSW Total Loss of Service Water AXMMSAFWPC Failure of SAFW Pump IC train AXMMSAFWPD Failure of SAFW Pump 1D Train NOSEO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump P5N01B Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01 D Is In Operation SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1B SW Pump Bin maintenance SWTMPUMPIC SW Pump C in maintenance TRANSX TAG - TRANSIENT EVENT 557 TI0000SW Total Loss of Service Water AXMMSAFWPC Failure of SAFW Pump 1IC train AXMMSAFWPD Failure of SAFW Pump 1D Train NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW(I1B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWMMSWPDRI FAILURES OF SW PUMP 0 TO RUN SWTMPUMP1A SW Pump A In maintenance SWTMPUMP1C SW Pump C in maintenance TRANSX TAG - TRANSIENT EVENT 558 T10000SW Total Loss of Service Water AXXVN09728 3 way valve 9728 fails to operate NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWrMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWThmPUMP1C SW Pump C In maintenance TRANSX TAG - TRANSIENT EVENT 559 T10000SW Total Loss of Service Water AXXVN09728 3 way valve 9728 faio to operate NOSBO TAG - NO STATION BLACKOUT PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWO1 D Is In Operation SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMPIA SW PumpA to maintenance SWTMPUMP1C SW Pump C in maintenance TRANSX TAG - TRANSIENT EVENT Report Summary:
Frlename: DACAFTA-W\\QUANTtLEVEL I\\@POWERI.CUT Print date: 06/22/2001 1:45 PM Not sorted Printed in full 1 1.93E200 I 1.00E+00 0.88 8.78E-01 0.58 5.79E-01 0.02 2.47E-02 5.53E-07 1 4.84E-03 0.03 3.13E-02 0.04 3.56E-02 I 1.O0E+00 1 1.002E+0 0.00E+00 5.19E-03 5.19E-03 I 1.93E+00 1 I.0OE+00 0.88 8.78E-01 0.42 4.21E-01 5.53E-07 1 4.84E-03 0.05 4.55E-02 0.04 3.56E-02 7.16E-03 7.15E-03 1 1.OOE+00 1 1.00E+00 0.00E+00 5.19E-03 5.19E-03 1 1.93E-00 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.02 2.47E-02 5.53E-07 1 4.84E-03 0.05 4.55E-02 7.15E-03 7.15E-03 1 1.00E+00 1 1.00E+O0 0.00E+00 5.1E-03 5.19E-03 1 1.93E+00 1 1.00E+00 0B88 8.76E-01 0.58 5.79E-01 0.02 2.47E-02 5.53E-07 1 4.84E-03 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 O.OOE+00 5.19E-03 5.19E-03 1 1.93E+00 I 1.00E+00 0.85 8.76E-01 5.53E-07 1 4.84E-03 5.53E-07 1 4.84E-03 0.03 3.13E-02 0.04 3.56E-02 I 1.00E+00 1 1.OOE+00 0.00E+00 0.02 2.29E-02 0.02 229E-02 1 1.OOE+0O 0e88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 1 1.00E+00 I 1.00E+D0 0.0OE+00 0.02 2.29E-02 0.02 2.29E-02 1 1.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.02 2.47E-02 0.02 2.47E-02 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.00E-03 1 1.00E-03 1 1.00E+00 0.88 8.762-01 0.42 4.21E-01 0.58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 0.04 3.66E-02 1 1.00E+00 1 1.00E+00 0.00E+00 1.tOE-03 I 1.00E-03 I 1.00E+00 0.88 8.7BE-01 0.58 5.79E-01 0.58 5.792-01 0.02 2.47E-02 0.02 2.47E-02 0.03 3.13E-02 0.04 3.56E-02 1 1.00E+00
No.01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING AmerGen Energy Company, LLC Oyster Creek Nuclear Generating Station 05000219 Time and Date:
Location:
Purpose:
NRC Attendees:
Licensee Attendees:
Friday, August 3, 2001, at 10:00 a.m.
U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415 A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.
J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)
J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)
V. Ordaz, Chief, Reactor Safeguards Section Chief, NRR D. Orrik, Reactor Security Specialist, NRR L. Dudes, Senior Resident Inspector, Oyster Creek, DRP P. Frechette, Physical Security Inspector, DRS D. Holody, ORA Staff J. Nick, ORA Staff J. Benjamin, Vice President, Licensing and Regulatory Affairs R. DeGregorio, Vice President, Oyster Creek E. Harkness, Plant Manager, Oyster Creek H. McNally, Manager, MAROG Security G. Vanderheyden, Vice President, MAROG J. Hutton, Director, Licensing Licensee:.
Facility:
Docket No:
2 Note: This meeting is closed to public observation since the matters to be discussed involve Safeguards Information. Attendance by additional NRC personnel to the meeting should be made known by July 25, 2001, to John White, Chief, Radiation Safety and Safeguards Branch, Region 1, at 610-337-5114.
Approved By:
John F. Rogge, Chief Projects Branch 7 Division of Reactor Projects
3 Distribution:
DOCUMENT NAME: G:\\RSSB\\FRECHET'ROCMTGNOTICE.WPD After declaring this document "An Official Agency Record" it will/will not be released to the Public.
To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRS RI/DRS H RI/DRP NAME PFrechette JWhite JRogge DATE 07/17/01 07/
/01 107/
/01 07/ /01 07/ /01 OFFICIAL RECORD COPY
No.01-042 U.S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING AmerGen Energy Company, LLC Oyster Creek Nuclear Generating Station 05000219 Time and Date:
Location:
Purpose:
NRC Attendees:
Licensee Attendees:
Friday, August 3, 2001, at 10:00 a.m.
U.S. Nuclear Regulatory Commission Region I Public Meeting Room 475 Allendale Road King of Prussia, PA 19406-1415 A Regulatory Conference to discuss a preliminary white finding involving the failure of the security organization to successfully interdict a mock adversary force in one of the force-on-force exercises conducted during an Operational Safeguards Readiness Evaluation (OSRE) on May 9, 2001; and documented in NRC Inspection Report 05000219/2001-011, dated June 22, 2001.
J. Wiggins, Deputy Regional Administrator W. Lanning, Director, Division of Reactor Safety (DRS)
J. White, Chief, Radiation Safety and Safeguards Branch, DRS G. Smith, Senior Physical Security Inspector, DRS J. Rogge, Chief, Projects Branch 7, Division of Reactor Projects (DRP)
V. Ordaz, Chief, Reactor Safeguards Section Chief, NRR D. Orrik, Reactor Security Specialist, NRR L. Dudes, Senior Resident Inspector, Oyster Creek, DRP P. Frechette, Physical Security Inspector, DRS D. Holody, ORA Staff J. Nick, ORA Staff J. Benjamin, Vice President, Licensing and Regulatory Affairs R. DeGregorio, Vice President, Oyster Creek E. Harkness, Plant Manager, Oyster Creek H. McNally, Manager, MAROG Security G. Vanderheyden, Vice President, MAROG J. Hutton, Director, Licensing Licensee:
Facility:
Docket No:
2 Note: This meeting is closed to public observation since the matters to be discussed involve Safeguards Information. Attendance by additional NRC personnel to the meeting should be made known by July 25, 2001, to John White, Chief, Radiation Safety and Safeguards Branch, Region 1, at 610-337-5114.
Approved By:
John F. Rogge, Chief Projects Branch 7 Division of Reactor Projects
3 Distribution:
(Note: Include: OE Mail; PMNS; OE Web; and S. Bogle, OE)
DOCUMENT NAME: G:\\RSSB\\FRECHETT\\OCMTGNOTICE.WPD After declaring this document "An Official Agency Record" it will/will not be released to the Public.
To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRS RI/DRS RI/DRP L
NAME PFrechette JWhite JRogge DATE 07/17/01 07/
/01 07/
/01 07/ /01 07/ /01 OFFICIAL RECORD COPY
a Cutsets with Descriptions Report LSW-INIT1 = 2.01E-04 DI.CAFTA-06/22/2001 13:15 Inputs Description Rate Exposure Event Pinb Probabtlity 1 TI00OSW Total Loss of Service Water 1
1.00E200 1.06E-04 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCIPUMPSR Common Cause Failure Of Service Waoter Pumps To Run 1.21E-04 1.21E-04 2 TIOOOOSW Total Loss of Service Water 1
1.0E++00 8.76E-05 PCF PLANT CAPACITY FACTOR 0.88 8.76E201 SWCXXSUCTI TOTAL FAILURE OF COMMON SW/FIRE WATER SUCTION (INITIATOR) 1.00E-04 1.00E-04 3 TIOOOSW Total Loss of Service Water 1
1.00E+00 1.16E-06 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1
8.80E-03 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWTMPUMPI B SW Pump B in mainrenance 0.05 4.55E-02 4 TI0000SW Total Loss of SerNce Water 1
1.00E+00 9.05E-07 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E-03 ACTRAINS TAG - Failure Of AC Train S 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWMMOSWPAO FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 5 TIOOOOSW Total Loss of Service Water 1
1.002+00 8.84E-07 ACB2FISS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E-03 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Fa/ure Of Service Water Pumps To Start 1.14E-04 1.14E-04 6 TI0000SW Total Loss of Service Water 1
1.002+00 8.84E-07 ACB2FIBS18 Local Fauh on 480 VAC Bus 18 1.01E-06 1
8.85-E03 ACTRAINA TAG - Failure ofAC Train A 1
1.00E+00 PCP PLANT CAPACITY FACTOR 0.88 8.76E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 7 TIO00OSW Total Loss of Service Water 1
1.00E+00 7.96E-07 ACB2FIBSI7 Local Fault on 480 VAC Bus 17 1012-06 1
8.85E-03 ACTRAINB TAG - Failure of AC Train 8 1
1.0E-+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3,28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance
.003 3.13E-02 8 TI0000SW Total Loss of Service Water 1
1.00E+00 5.64E-07 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E.03 ACB2FTSS18 Local Fault on 480 VAC Bus 18 1.012-06 72 7.27E-05 ACTRAINA TAG - Failure ofAC Train A 1
1.00E+00 ACTRAIN TAG - Pailure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 9 TIOOOOSW Total Loss of Service Water 1
1.00E+00 5.64E-07 ACE2FIBS18 Local Fault on 480 VAC Bus 18 1.01 E-06 1
8.85E-03 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-56 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1,00E+00 ACTRAIN TAG - Pailunm n/AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 10 TIOOOSW Total Loss of Service Water 1
1.00E+00 1.82E-07 ACB2FIBS18 Local Fault on 480 VAC Bus 10 1.01E-06 1
8.85E-03 ACTRAINA TAG - Fa/lure of AC Train A 1
1.05E-00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWTMPUMPID SW Pump D io maintenance 7.15E-03 7.15E-03 11 TI0000SW Total Loss Of Service Water 1
1.00E+00 1.40E-07 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E-03 ACB2FIBS1E Local Fault on 480 VAC Bus 18 1.01E-06 1
8.85E-03 ACTRAINA TAG - Fa/lure of AC Train A 1
1.00E+00 ACTRAIN TAG - Pa/oure n/AC Trains 1
1.00E+00 DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS< 30 DEGREES AND INTAKE HEATERS ENE 0.12 1.23E-01 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SI (3 0.02 1.66E-02 12 T10000SW Total Loss of Service Water 1
1.00E+00 1.19E-07 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1
8.85E-03 ACTRAINA TAG - Failure ofAC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88
&.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCVC04603 Service Water Pump PSWOIC Discharge Check Valve 4603 Fails To Close On 5.84E-04 1
5.84E-04 SWTMPUMPI B SW Pump B In maintenance 0.05 4.55E-02 13 TI0OOOSW Total Loss of Service Water 1
1.00E+00 9833E-08 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 I
8.85E-03 ACTRAINB TAG - Failure of AC Train O I
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWI0B Is In Operation 0.88 5.79E-01 SWCVC04602 Service Water Pump PSWOI B Discharge Check Valve 4602 Fails To Close On 5.84E804 1
5.84E-04 SWTMPUMPIC SW Pump C in maintenance 0.04 3.562-02 14 T10000SW Total Loss of Service Water 1
1.00E+00 8.342-0 ACB2PIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E-03 ACTRAINB TAG - Failure ofAC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E.03 3.28E-03 15 TI00OSW Total Loss of Service Water 1
1.00E200 8.34E-08 ACB2FIBSI8 Local Fault on 480 VAC Bus Ia 1.01E-06 1
8.85E-03 ACTRAINA TAG - Failure ofAC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 18 TI0000SW Total Loss of Service Water 1
1.00E+00 8.20E-08 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E-03 ACTRAINB TAG - Failure ofAC Train B 1
1.002+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWCVC04604 Service Water Pump PSW01D Discharge Check Valve 4604 Fails To Close On 5.94E.04 1
5.84E-04 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT 1
1.00E+00 SWTMPUMPIA SW Pump A in maintenance 0.03 3.132-02 17 TI00OOSW Total Loss of Service Water 1
1.00E+00 7.222-08 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1
8.85E-03 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.052-04 SWTMPUMPIB SW Pump B in maintenance 0.00 4.552-02 10 TI0000SW Total Loss of Service Water 1
1.002+00 5.892-08 PCF PLANT CAPACITY FACTOR 088 8.70E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWSOIA 1.002-06 1
&.78E-03 SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWSO1B 1.00E-06 1
8.76E-03 SWISFFSWCI PLUGGING OF TRAVELLING SCREEN FWS01C 1.00E-06 1
8.76E-03 19 TIOOOOSW Total Loss of Service Water 1
1.00E+00 5.89E208 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 LO0SLOŽ.XKL SS
SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-01 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWSO1A 1.00E-06 1
8&78E-03 SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWS01B 1.00E-06 I
8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS010 1.001-06 1
8.76E-03 20 TIO0OOSW Total Loss of Service Water 1
1.00E.00 5.89E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-C1 SWTSFFSWAI PLUGGING OF TRAVELLING SCREEN FWS01A 1.00E-06 1
8.76E-03 SWTSFFSWCI PLUGGING OF TRAVELLING SCREEN FWS01C 1.00E-08 I
8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS01D 1.00E-06 1
8.76E-03 21 TI0000SW Total Loss of Service Water 1
1.00E+00 5.89E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASCREEN FLAG - CONDITIONS EXIST WHERE TRAVELLING SCREENS ARE NECESSARY 0.1 1.00E-O SWTSFFSWBI PLUGGING OF TRAVELLING SCREEN FWS01B 1.00E-06 1
8.76E-03 SWTSFFSWCI PLUGGING OF TRAVELLING SCREEN FWS01C 1.001-06 1
8.76E-03 SWTSFFSWDI PLUGGING OF TRAVELLING SCREEN FWS01D 1.00E-06 8 8.78E-03 22 TI0000SW Total Loss of Service Water 1
1.008+00 5.65E-08 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 I
8.85E-03 ACTRAINB TAG - Failure of AC Train E 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 23 TI0000SW Total Loss of Service Water 1
1.00E+00 4.96E-08 AC82FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.851-03 ACTRAINB TAG - Failure of AC Train 8 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 24 TI0000SW Total Loss of Service Water 1
1.00E+00 2.80E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWMlA Is In Operation 0.58 5.79E-01 SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.21E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMPI B SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 25 TI00O0SW Total Loss of Service Water I
1.00E+00 2.80E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BNR FLAG - Service Water Pump PSWOIB Is Not In Operation 0.42 4.21 E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 0.00 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 26 TI0000SW Total Loss of Service Water 1
1.008+00 2.74E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPDRI FAILURES OF SW PUMP 0 TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump S in maintenance 0.05 4.55E-02 27 TI0000SW Total Loss of Service Water 1
1.00E+00 2.68E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 28 TI0000SW Total Loss of Service Water 1
1.00E+00 2.14E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E801 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICNR FLAG-Service Water Pump PSWOIC Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 29 TI0000SW Total Loss of Service Water 1
1.00E+00 2.09E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 6.78E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 30 TI000OSW Total Loss of Service Water 1
1.00E+00 2.05E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.88 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN.
0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 31 TI0000SW Total Loss of Service Water 1
1.00E+00 2.05E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01 D Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPBRI FAILURES OF SW PUMP 8 TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 32 TI00O0SW Total Loss of Service Water 1
1.00E+00 1.88E-08 PCF PLANT CAPACITY FACTOR 0.88 8.761-01 SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.88 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 33 TI0000SW Total Loss of Service Water 1
1.00E+00 1.87E-08 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1
8.85E-03 ACTRAINA TAG - Failure of AC Train A 1
1.06E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWCVC04601 Service Water Pump PSW0IA Discharge Check Valve 4801 Fais To Close On 5.84E-04 1
6.84E-04 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.158-03 34 TI0000SW Total Loss of Service Water 1
1.00E+00 1.84E-08 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1OR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Iotn Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1A SWPumpA in maintenance 0.03 3.13E-02 35 TI0000SW Total Loss of Service Water 1
1.00E+00 1.75E-08 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01
SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 36 TIOOOOSW Total Loss of Service Water 1
1.00E+00 1.37E-08 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-CO 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.0OE÷00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWPICNR FLAG - Service Water Pump PSWO1C Is Not In Operation 0.42 4.21E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 37 T10000SW Total Loss of Service Water 1
1.00E+00 1.30E-08 AC82FTBS17 Local Fault on 480 VAC Bus 17 1.018-06 72 7.27E-05 ACTRAINB TAG - Faiur Of AC Train B 1
1.008+00 PCO PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWOlA Is In Operation 0.58 5.79E.01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 38 TISOOOSW Total Loss of Service Water 1
1.00E+00 1.30E-08 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWoIB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 39 TSOOOOSW Total Loss of Service Water 1
1.OE-.00 1.20E-08 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failura of AC Train B 1
1.00E800 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIANR FLAG - Service Water Pump PSWO1A Is Not In Operation 0.42 4.21E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 40 TIOOOOSW Total Loss of Service Water 1
1.008E00 1.12E-08 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1
8.85E-03 ACTRAINA TAG - Failure of AC Train A I
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.15E-03 41 TI0000SW Total Loss of Service Water 1
1.00E800 9.49E-09 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWMvIMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER "0" PIPING RUPTURE 5.53E-07 1
4.84E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 42 TIOOOOSW Total Loss of Service Water 1
1.00+O00 9.49E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation 0.42 4.211E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A PIPING RUPTURE 5.53E-07 1
4.84E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 43 TIOODOSW Total Loss of Service Water 1
1.00E+00 9.27E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1
4.84E-03 SWTMPUMP1B SW Pump s in maintenance 0.05 4.55E-02 44T10000SW Total Loss of Service Water 1
1.00E+00 9.06E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1
4.84E-03 SWTMPUMP1B SW Pump B In maintenance 0.05 4.555-02 45 Ti0000SW Total Loss of Service Water 1
1.0OE+00 9.06E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1
4.84E-03 SWTMPUMP1B SW Pump B In maintenance 0.05 4.55E-02 46 TIOOOSW Total Loss of Service Water 1
1.00E+00 8.608-09 ACB2FIB17 Local Fault on 480 VAC Bus 17 1.01E-08 1
8.855-03 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW1 B Is In Operation 0.58 5.79E-01 SWCVC04602 Service Water Pump PSWO1 B Discharge Check Valve 4602 Fails To Close On 5.84E-04 1
5.84E-04 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.285-03 3.28E-03 47 TIOOOOSW Total Loss of Service Water 1
1.00E+00 8.60E-09 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
8.85E-03 ACTRAINS TAG - Failure of AC Train B 1
1.001200 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWCVC04604 Service Water Pump PSWO1D Discharge Check Valve 4604 Falls To Close On 5.84E-04 1
5.84E-04 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT 1
1.00E+00 48 TISOOOSW Total Loss of Service Water 1
1.00E+00 8.60E-09 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1
8.85E-03 ACTRAINA TAG - Failure of AC Train A 1
1.005+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWCVC04601 Service Water Pump PSW01A Diclsarge Check Valve 4601 Fails To Close On 5.84E-04 1
5.84E-04 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 49 TI00OOSW Total Loss of Service Water 1
1.00E+00 8.60E-09 ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1
8.85E-03 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 5.76E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWCVC04603 Service Water Pump PSW01C Discharge Check Valve 4603 Falls To Close On 5.84E-04 1
5.84E-04 SWMMOSWPSS FAILURES OF SW PUMP S TO START 3.28E-03 3.28E-03 50 TI0000SW Total Loss of Service Water 1
1.00E+00 7.26E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPICNR FLAG - Service Water Pump PSWO1C Is Not In Operation 0.42 4.21E-01 SWCCPUMPSS Comnmon Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 6.53E-07 1
4.84E-03 SWtMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 51 TI000OSW Total Loss of Service Water 1
1.00E+00 7.09E-09 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B I In Operation 0.58 5.79E-01
SWMMOSWPAS FAILURES OF SIN PUMP A TO START SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMPIC SW Pump C in maintenance 52 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE SWTMPUMPIC SW Pump C In maintenance 53 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWPPJIHDRB SERVICE WATER HEADER "8" PIPING RUPTURE 54 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW018 Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 55 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1CR FLAG - Service Water Pump PSW0t C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 56 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIDR FLAG - Service Water Pump PSW0ID It In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 57 1I0000SW Total Loss of Servica Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMP1A SW Pump A in maintenance 58 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW0lB Is In Operation SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMP1A SW Pump A in maintenance 59 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1DR FLAG - Service Water Pump PSW01 D Is In Operation SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE SWTMPUMP1A SW Pump A in maintenance 60 TI0000SW Total Loss of Service Water ACB2FTBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW1 B Is Not In Operation SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMPIB SW Pump B in maintenance 61 TOOSOOSW Total Loss of Service Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 62 TI0000SW Total Loss of Service Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 63 T10000SW Total LOSS of Service Water ACB2FIBS18 Local Fault on0 40 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 64 TI0000SW Total Loss of Service Water ACB2FIPS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 65 T10000SW Total Loss of Service Water ACB2FTBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWPPJIHDRA SERVICE WATER HEADER *A" PIPING RUPTURE SWTMPUMPIC SW Pump C in maintenance 66 TI0000SW Total Loss of Service Water ACB2FTBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train S PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 67 T10000SW Total Loss of Service Water ACB2FTBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train s PCF PLANT CAPACITY FACTOR SWAASWP1CR FLAG - Service Water Pump PSWO0C Is In Operation SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 88 TI000OSW Total Loss of Service Water ACB2FTBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 3.28E-03 0.02 5.53E-07 I
0.04 1
0.88 0.58 3.28E-03 0.02 5.53E-07 1
0.04 1
0.88 0.58 1.14E-04 0.02 5.53E-07 I
I 0.88 0.58 1.14E-04 0.02 5.53E-07 I
0.88 0.08 1.14E-04 0.02 5.53E-07 1
1 0.80 0.58 1.14E-04 0.02 5.53E-07 1
1 0.88 0.42 1.14E0-04 5.53E-07 1
0.03 1
0.88 0.58 3.28E-03 0.02 5.53E-07 1
0.03 1
0.88 0.58 3.28E-03 0.02 5.53E-07 1
0.03 1
1.0tE-0B 72 1
0.88 0.42 5.53E-07 1
0.05 I
1.01 E-06 1
I 0.88 3.28E-03 2.03E-04 I
1.01 E-08 1
1 0.88 3.28E-03 2.OE-04 I
1.01E-06 1
1 0.88 3.28E-03 2.05E-04 1.01E-06 1
0.80 3.28E-03 2.02E-04 I
1.01E-06 72 1
0.88 0.42 5.53E-07 1
0.04 1
1.01E-06 72 1
0.88 0.58 0.02 5.53E-07 1
1 1.01E-06 72 1
0.88 0.58 0.02 5.53E-07 1
1 1.01E-06 72 1
0.88 0.58 0.02 5.53E-07 1
3.28E-03 2.47E-02 4.84E-03 3.56E-02 1.00E+00 7.09E-09 8.76E-01 5.79E-01 3.28E-03 2.47E-02 4.84E-03 3.56E-02 1.00E+00 6.83E-09 8.76E-01 5.79E-01 1.14E-04 2.47E-02 4.04E-03 1.00E+00 6.93E-09 8.76E-01 5.79E-01 1.14E-04 2.47E-02 4.84E-03 1.00E+00 6.93E-09 8.78E-01 5.79E-01 1.14E-04 2.47E-02 4.84E-03 1.00E+00 6.93E-09 8.76E-01 5.79E-01 1.14E-04 2.47E-02 4.04E-03 1.00E+00 6.38E-09 8.76E-01 4.21E-01 1.14E-04 4.04E-03 3.13E-02 1.00E+00 6.23E-08 8.76E-01 5.79E-01 3.28E-03 2.47E-02 4.84E0-3 3.13E-02 1.00E+00 6.23E-09 8.76E-01 5.79E-01 3.28E-03 2.47E-02 4.84E-03 3.130-02 1.00E+00 5.91E-09 7.27E-05 1.00E+00 8.76E-01 4.21E-01 4.84E-03 4.550-02 1.00E+00 5.20E-09 8.80E-03 1.00E+0O 8.76E-01 3.28E-03 2.05E-04 1.00E+00 0.20E-09 8.85E-03 1.00E+00 8.76E-01 3.280-03 2.05E-04 1.00E+00 5.20E-09 8.85E-03 1.00E+00 8.76E-01 3.28E-03 2.05E-04 1.000+00 5.13E-09 8.85E-03 1.00E+00 8.76E-01 3.281-03 2.02E-04 1.00E+00 4.83E-00 7.27E-05 1.00E+00 8.76E-01 4.21E-01 4.94E-03 3.56E-02 1.O0E+00 4.42E-09 7.27E-05 1.00E+00 8.76E-01 5.79E-01 2.47E-02 4.84E-03 1.00E+00 4.42E-09 7.27E-05 1.00E+00 8.76E-01 5.79E-01 2.47E-02 4.84E-03 1.000+00 4.42E-09 7.27E-05 1.00E+00 8.76E-01 5.79E-01 2.47E-02 4.04E-03
69 TI0000SW Total Loss of Service Water ACB2FTBSl8 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Faulure of AC Train A PCF PLANT CAPACITY FACTOR SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE 70 TI000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPtBR FLAG - Service Water Pump PSW01t Is In Operation SWAASWP1 DNR FLAG - Service Water Pump PSWO1D Is Not In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start SWMMSWPERI FAILURES OF SW PUMP B TO RUN SWTMPUMPtD SW Pump D in maintenance 71 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPtAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPBS FAILURES OF SW PUMP S TO START SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMP1 0 SW Pump D in maintenance 72 Ti0000SW Total Loss of Service Water ACE2FTBS17 Local Fault on 480 VAC Bus 17 ACTRAINS TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSWOtA Is Not In Operation SWPPJIHDRB SERVICE WATER HEADER 8E" PIPING RUPTURE SWTMPUMPIA SW Pump A In maintenance 73 TI00OOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMIMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMPIA SW Pump A in maintenance SWTMPUMPID SW Pump D in maintenance 74 Ti0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1 DNR FLAG - Service Water Pump PSWOID Is Not In Operation SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPBRI FAILURES OF SW PUMP S TO RUN SWTMPUMP1A SW Pump A in maintenance SWrMPUMPID SW Pump D in maintenance 75 TI00OQSW Total Loss of Service Water ACB2FTBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWAASWPI BR FLAG - Service Water Pump PSWOIB Is In Operation SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation SWMMSWPBRI FAILURES OF SW PUMP S TO RUN SWTMPUMP1D SW Pump D in maintenance 78 TI000OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1B SW Pump B in maintenance 77 Ti0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMOSWPES FAILURES OF SW PUMP S TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWTMPUMPIC SW Pump C in maiatenance 78 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 79 Ti0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWO1E Is In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPSRI FAILURES OF SW PUMP B TO RUN SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 80 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMPIA SW Pump A In maintenance 81 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW0tA Is In Operation SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWTMPUMPIB SW Pump Bin maintenance SWTMPUMPIC SW Pump C in maintenance 82 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW0I8 Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1B SW Pump S in maintenance SWTMPUMPIC SW Pump C in maintenance 83 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN I
1.01E-08 72 1
0.88 0.58 0.02 5.53E-07 1
1 0.88 0.58 0.42 1.14E-04 0.02 7.15E-03 1
0.88 0.58 0.58 3.28E-03 0.02 0.02 7.16E-03 I
1.01E-06 72 1
0.88 0.42 6.53E-07 1
0.03 1
0.88 0.42 0.58 3.28E-03 0.02 0.03 7.15E-03 1
0.88 0.58 0.42 3.28E-03 0.02 0.03 7.1 SE-03 I
1.0112-0 72 1
0.88 0.58 0.42 0.02 7.15E-03 I
0.88 0.42 0.58 3.28E-03 3.28E-03 0.02 0.05 0.88 0.58 0.42 3.28E-03 3.28E-03 0.02 0.04 0.88 0.58 0.58 3.28E-03 3.28E-03 0.02 0.02 0.88 0.58 0.58 3.280E-03 3.28E-03 0.02 0.02 0.88 0.42 0.2 8 3.28E-03 3.20E-03 0.02 0.03 0.88 0.58 0.42 0.02 2.05E-04 0,05 0.04 0.88 0.42 0.58 2.05E-04 0.02 0.05 0.04 0.88 0.58 0.58 0.02 1.00E+00 4.42E-00 7.27E-05 1.00E+00 8.78E-01 5.79E-01 2.47E-02 4.84E-03 1.00E+00 4.300-08 8.76E-01 5.79E-01 4.21E-01 1.14E-04 2.47E-02 7.151-03 1.000+00 4.21E-09 8.76E-01 5.79E-01 5.780E01 3.28E-03 2.47E-02 2.47E-02 7.15E-03 1.00E+00 4.07E-09 7.27E-05 1.00E+00 8.78E-01 4.21E-01 4.84E-03 313E-02 1.00E+00 3.87E-09 8.78E-01 4.21E-01 5.78E-01 3.28E-03 2.47E-02 3.13E-02 7.15E-03 1.00E+00 3.87E-09 8.70E-01 5.79E-01 4.21E-01 3.280E-03 2.47E-02 3.13E-02 7.15E-03 1.00E+00 2.74E-09 7.27E-05 1.00E+00 8.78E-01 5.79E-01 4.21E-01 2.47E-02 7.15E-03 1.00E+00 2.58E-08 8.78E-01 4.21E-01 5.79E-01 3.280-03 3.280E-03 2.47E-02 4.55E-02 1.00E+00 2.02E-09 8.78E-01 5.79E-01 4.21E-01 3.28E-03 3.28E-03 2.47E-02 3.56E-02 1.00E+00 1.93E-09 8.761-01 5.79E-01 5.79E-01 3.28E-03 3.28E-03 2.47E-02 2.47E-02 1.00E+00 1.83E-09 8.76E-01 5.79E-01 5.70E-01 3.28E-03 3.28E-03 2.47E-02 2.47E-02 1.00E+00 1.78E-09 8.78E-01 4.21 E-01 5.79E-01 3.280E-03 3.28E-03 2.47E-02 3.13E-02 1.00E+00 1.75E-09 8.760-01 5.79E-01 4.21E-01 2.47E-02 2.05E-04 4.55E-02 3.56E-02 1.00E+00 1.75E-09 8.78E-01 4.21E-01 5.70E-01 2.05E-04 2.47E-02 4.55E-02 3.56E-02 1.000+00 1.67E-0M 8.78E-01 5.70E-01 5.79E-01 2.47E-02
SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 SWTMPUMPIS SW Pump B in maintenance 0.05 84 TIOO00SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1
SWIMPUMPID SW Pump D In maintenance 7.19E-03 85 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 SWPPJIHDRB SERVICE WATER HEADER "B' PIPING RUPTURE 5.53E-07 I
SWTMPUMP1D SW Pump D in maintenance 7.15E-03 88 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPICR FLAG - Service Water Pump PSW0IC Is In Operation 0.58 SWMMOSWPBS FAILURES OF SW PUMP S TO START 3.28E-03 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE 5.53E-07 1
SWTMPUMP1D SW Pump D in maintenance 7.15E-03 87 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 SWMMOSWPSS FAILURES OF SW PUMP B TO START 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER'S" PIPING RUPTURE 5.53E-07 I
SWTMPUMPIA SW Pump A in maintenance 0.03 SWTMPUMPID SW Pump D In maintenance 7.15E-03 88 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 I
SWTMPUMPIA SW Pump A In maintenance 0.03 SWTMPUMPID SW Pump D in maintenance 7.15E-03 88 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSWIB Is In Operation 0.58 SWAASWP1DR FLAG - Service Water Pump PSWOID ls In Operation 0.58 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 SWTMPUMPIC SW Pump C in maintenance 0.04 90 TIOO00SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIB R FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWPIDR FLAG - Service Water Pump PSW1ID Is In Operation 0.58 SWMMSWPBRI FAILURES OF SW PUMP S TO RUN 0.02 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 SWTMPUMP1A SW Pump A in maintenance 0.03 91 T10000SW Total Loss of Service Water I
ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 ACTRAINA TAG - Failure of AC Train A 1
PCF PLANT CAPACITY FACTOR 0.83 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1
SWTMPUMP1D SW Pump D in maintenance 7.15E-03 92 TI0000SW Total Loss of Service Water 1
ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1
ACTRAINS TAG - Failure of AC Train B 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1SR FLAG - Service Water Pump PSW01S Is In Operation 0.58 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCVC04602 Service Water Pump PSWO1S Discharge Check Valve 4602 PFais To Close On 5.84E.04 1
SWCVC04604 Service Water Pump PSWO1D Discharge Check Valve 4804 Fails To Close On 6.84E-04 1
SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT 1
93 TI0000SW Total Loss of Service Water I
ACS2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-06 1
ACTRAINA TAG - Failure of AC Train A I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 SWCVCD4601 Service Water Pump PSW01A Discharge Check Valve 4601 Falls To Close On 5.84E-04 1
SWCVC04603 Service Water Pump PSW01C Discharge Check Valve 4603 Fais To Close On 5.84E-04 1
94 T10000SW Total Loss of Serifce Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBNR FLAG - Service Water Pump PSW01 B Is Not In Operation 0.42 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER "B' PIPING RUPTURE 5.53E-07 1
SWTMPUMP1 B SW Pump B in maintenance 0.05 95 T10000SW Total Loss of Service Water 1
ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
ACTRAINB TAG - Failure of AC Train B S DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Coad Enough to Cause Frazil Ice and Loss of SW (3 0.02 SWHHFCWOIA Circulating Water Intake Heater CWO1A Pails 2.29E-08 24 96 11D000SW Total Loss of Service Water I
ACB2FISS17 Local Fault on 480 VAC Bus 17 1.010-06 1
ACTRAINB TAG - Failure of AC Train B 1
DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (3 0.02 SWHHFCW01C Circulating Water Intake Heater CW01C Fails 2.29E-08 24 97 TIOOOOSW Total Loss of Service Water 1
ACB2FIBS18 Local Fault on 480 VAC sus 18 1.01E-06 1
ACTRAINA TAG - Failure of AC Train A 1
DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Coal Enough to Cause Frazn Ice and Loss of I (3 0.02 SWHHFCW01S Cirulating Water intake Heater CW018 Fails 2.29E-08 24 98 T10000SW Total Loss of Service Water 1
ACB2FIBS10 Local Fault on 480 VAC Bus 18 1.010-08 1
ACTRAINA TAG - Failure of AC Train A 1
DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SIN (3 0.02 SWHHFPCW01D Circulating Water Intake Heater CWOID Fails 2.29E-06 24 99 T10000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 2.47E-02 2.05E-04 4.55E-02 1.00E-00 1.48E-09 8.76E-01 4.21E-01 1.14E-04 4.84E-03 7.15E-03 1.00E+00 1.42E-09 8.76E-01 5.79E-01 3.28E-03 2.47E-02 4.84E-03 7.15E-03 1.00E+00 1.42E-09 8.70E-01 5.79E-01 3.28E-03 2.47E-02 4.84E-03 7.15E-03 1.00E+00 1.31E-09 8.78E-01 4.2112-01 3.28E-03 4.84E-03 3.13E-02 7.15E-03 1.00E+00 1.31E-09 8.76E-01 4.21E-01 3.28E-03 4.84E-03 3.13E-02 7.15E-03 1.00E+00 1.31E-09 8.76E-01 5.79E-01 5.79E-01 2.05E-04 2.47E-02 2.47E-02 3.56E-02 1.00E+00 1.15E-09 8.76E-01 5.79E-01 5.79E-01 2.47E-02 2.05E-04 2.47E-02 3.13E-02 1.00E+00 9.29E-10 7.27E-05 1.000+00 8.76E-01 4.21E-01 4.84E-03 7.150-03 1.00E+00 8.86E-10 8.85E-03 1.000+00 8.76E-01 5.79E-01 5.79E-01 5.84E-04
&.84E-04 1.00E+00 1.00E+00 8.86E-10 8.85E-03 1.00E+00 8.76E-01 5.79E-01 5.79E-01 5.84E-04 5.84E-04 1.00E+00 8.75E-10 8.76E-01 4.21E-01 3.28E-03 3.28E-03 4.84E-03 4.55E-02 1.00E+00 8.70E-10 8.85E-03 1.00E+00 1.23E-01 8.76E-01 1.686-02 5.50E-05 1.00E+08 8.70E-10 8.85E-03 1.00E+00 1.23E-01 8.76E-01 1.66E-02 5.50E-05 1.00E+00 8.70E-10 8.85E-03 1.00E+00 1.23E-01 8.78E-01 1.66E-02 5.50E-05 1.00E÷00 8.70E-10 8.85E-03 1.00E+00 1.23E-01 8.76E-01 1.66E-02 5.50E-05 1.00E+00 8.85E-10 8.78E-01
SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 SWTMPUMPIC SW Pump C in maintenance 100 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 101 Tt000OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG-Service Water Pump PSWi1B Is In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRB SERVICE WATER HEADER 0"B PIPING RUPTURE 5.53E-07 102 TIO000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 103 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER A PIPING RUPTURE 5.53E-07 104 TI000OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSWOIA Is Not In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWPPJIHDRE SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 SWTMPUMP1A SW Pump A In maintenance 105 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSWO1 B Is Not In Operation SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2
SWPPJIHDRB SERVICE WATER HEADER "fr" PIPING RUPTURE 5.53E-07 SWTMPUMPIB SW Pump B in maintenance SWTMPUMP1C SW Pump C in maintenance 106 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 SWTMPUMPIB SW Pump B in maintenance SWTMPUMP1C SW Pump C in maintenance 107 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2
SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 SWTMPUMPIB SIN Pump B in maintenance 108 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2
SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 SWTMPUMP1B SW Pump B in maintenance 109 710000SW Totat Loss of Serace Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.011E-06 ACTRAINE TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWOt B Is In Operation SWCVC04602 Service Water Pump PSW01B Discharge Check Valve 4802 Fais To Ciose On 5.84E-04 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN
- 2.
110 TIOOOOSW Total Loss of Service Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation SWCVC04804 Service Water Pump PSW01 D Discharge Check Valve 4604 Fais To Close On 5.84E-04 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN
- 2.
SWPMPDINIT TAG - SW PUMP D FAILS AS AN INITIATING EVENT ItI TIOOO0SW Total Loss of Service Water ACB2FIBS18 Local Fault on 480 VAC Bus It 1.01E-06 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWCVC0460I Service Water Pump PSW01A Discharge Check Valve 4601 Fails To Close On 5.84E-04 SWMMSWPORT FAILURES OF SW PUMP D TO RUN
- 2.
112 TI00OSW Total Loss of Service Water ACB2FIBS18 Local Faunt on 480 VAC Bus 18 1.01E-06 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWCVC04603 Servce Water Pump PSW01C Discharge Check Valve 4603 Fails To Close On &84E-04 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.1 113 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWMM0SWPDS FAILURES OF SW PUMP D TO START 3.2 SWTMPUMP1B SW Pump B in maintenance UVREKI829A RELAY 29-A IN BUS 1 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 UVREKI129C RELAY 29-C IN BUS 10 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 114 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPiCR FLAG - Service Water Pump PSWOIC Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.2 SWTMPUMPIB SW Pump B in maintenance UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER28.94E-07 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 115 TIOOOSW Total Loss of Service Water 3.28 3.28 3.28 3.28 3.28 3.28 3.28 3.28 3.28 3.28 3.28E 3.281 2.05E 2.05E
.05E 0
0 0
0 0
05E
- 0.
05E
- 0.
- 0.
05E
- 0.
0.:
0-5 0.2 0.8 0.12 0.1 0.5 0.1 28E-0 0.1 0.8 0.5 0.S 8E-C 0.0 0.42 4.21E-01 8E-03 3.28E-03 8E-03 3.28E-03 I
4.84E-03 0.04 3.56E-02 1
1.00E+00 6.54E-10 0.88 8.76E-01 0.58 5.78E-01 1E-03 3.28E-03 E8-03 3.28E-03 0.02 2.47E-02 1
4.84E-03 1
1.00E000 8.84E-10 0.88 8.76E-01 0.58 5.79E-01 8E-03 3.28E-03 8E-03 3.28E-03 0.02 2.47E-02 1
4.84E-03 1
1.00E+00 8.54E-10 0.88 8.76E-01 0.58 5.79E-01 E-03 3.28E-03 E-03 3.28E-03 0.02 2.47E-02 1
4.84E-03 1
1.000200 6.54E-10 0.88 8.76E-01 0.58 5.79E-01 E-03 3.28E-03 E-03 3.28E-03 0.02 2.47E-02 1
4.84E-03 1
1.00E+00 6.02E-10 0.89 8.76E-01 0.42 4.21E801 E-03 3.28E-03 E-03 3.28E-03 1
4.84E-03 0.03 3.13E-02 1
1.00E+00 5.92E-10 0.88 8.78E-01 0.42 4.21E-01 E-04 2.05E-04 1
4.84E-03 0.05 4.55E-02 0.04 3.58E-02 1
1.00E+00 5.92E-10 0.88 8.76E-01 0.42 4.21E-01 E-04 2.05E-04 1
4.84E-03 0.05 4.55E-02 1.84 3.561-02 1
1.00E+00 5.88E-10 0.88 8.76E-01 1.58 5.79E-01 1.02 2.47E-02
-04 2.05E-04 1
4.84E-03 0.05 4.55E-02 1
1.00E+00 5.65E-10
'.88 8.76E-01
'.58 5.79E-01
'.02 2.47E-02
-04 2.05E-04 1
4.84E-03
.05 4.55E-02 1
1.00E+00 5.36E-10 1
8.85E-03 1
1.00E+00
.88 8.76E-01
.58 5.79E-01 1
5.84E-04 0-4 2.05E-04 1
1.00E+00 5.36E-10 1
8.85E-03 1
1.00E+00 88 8.76E-01 58 5.79E-01 1
5.84E-04 04 2.05E-04 1
1.00E+00 1
1.00E+00 5.36E-10 1
8.85E-03 1
1.00E+00 88 8.76E-01 58 5.79E-01 1
5.84E-04 D4 2.05E-04 1
1.00E+00 8.28E-10 1
8.85E-03 1
1.00E+00 88 8.78E-01 s8 5.79E-01 1
5.84E-04 04 2.02E-04 1
1.00E+00 5.228-10 88 8.76E-01 58 5.79E-01 58 5.79E-01 33 3.28E-03 05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 5.22E-10 88 8.76E-01 58 5.79E-01 58 5.79E-01 0
3.28E-03 05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.000+00 5.22E-10
PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1B SW Pump B in maintenance UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERM.94E-07 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2118 TRANSFERS TO ENERGIZED 3.94E-07 116 710000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C is In Operation SWMM0SWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1B SW Pump B in maintenance UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 117 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1B SW Pump B in maintenance UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/I 8 TRANSFERS TO DE-ENERGIZE3.94E-07 118 TI000OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOI C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMPIS SW Pump B In maintenance UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 119 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Servie Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMPIB SW Pump B in maintenance UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVREKO829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 120 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPoDS FAILURES OF SW PUMP D TO START SWTMPUMPIB SW Pump B in maintenance UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 121 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP 0 TO START SWTMPUMP1B SW Pump B in maintenance UVREKIO29B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER3.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 122 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1S SW Pump B in maintenance UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVRERI7ED8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 123 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA in In Operation SWAASWPtCR FLAG - Service Water Pump PSWOIC Is In Operation SWMM0SWPDS FAILURES OF SW PUMP D TO START 3
SWTMPUMP1B SW Pump B in maintenance UVREKI828C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 124 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START 3
SWTMPUMPI B SW Pump B in maintenance UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27I18 TRANSFERS TO DE-ENERGIZED 3.94E-07 125 110000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP 0 TO START
- 3.
SWTMPUMP1B SW Pump B in maintenance UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 126 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump P-WOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START
- 3.
SWTMPUMPIB SW Pump B in maintenance UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 127 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START 3J SWTMPUMPIB SW Pump B in maintenance UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 128 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PWOiC Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START
- 3.
SWTMPUMPI B SW Pump B in maintenance UVREKI829D RELAY 29-0 IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27DI18 TRANSFERS TO DEO-ENERGIZED 3.94E-07 129 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 3.2 3.21 3.28 3.28 3.28 3.28 3.281
.28 0.20 0
.285 0
0 0
- 0.
.28E
- 0.
- 0.
- 0.
- 0.
28
- 0.
- 0.
- 0.
0.,
28Eo 0.1 0.8 0.5 0.5 28E-0 0.0 0.8 0.5 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 8E-03 3.28E-03 0.05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00Ee00 0.22E-j1O 0.08 8.78E-01 0.58 5.79E-01 0.58 0.79E-01
.E-03 3.28E1-03 0.05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 5.22E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.70E-01 1E-03 3.280-03 0.05 4.55E-02 I
3.45E003 I
3.45E-03 1
1.00E+00 5.22E-10 0.88 8.78E-01 0.58 S.79E-01 0.58 5.79E-01 E-03 3.28E-03 0.05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.22E-10 0.08 8.76E-01 0.58 5.79E-01 0.08 5.79E-01 E-03 3.28E003 0.05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 5.22E-10 0.88 8.76E-01 0.58 5.79E-01 0.08 5.79E-01 E-03 3.28E-03 0.05 4.55E-02 1
3.451-03 1
3.45E-03 1
1.002+00 5.22E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 E-03 3.28E-03 0.05 4.550-02 I
3.45E-03 1
3.45E-03 I
1.00E+00 5.22E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 E-03 3.20E-03 0.05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.22E-10 1.88 8.76E-01 0.08 0.79E-01 1.58 6.79E-01 E-03 3.28E-03 1.05 4.55E-02 1
3.45E-03 I
3.45E-03 1
1.00E+00 5.22E-10 0.88 8.76E-01 0.58 5.79E-01 058 5.79E-01
"-03 3.28E-03
'.05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 5.22E-10
.88 8.78E-01
.58 5.79E-01 s.8 5.79E-01
"-03 3.28E-03
.05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 5.22E-10
.88 8.78E-01
.58 5.79E-01 58 0.79E-01 03 3.28E-03 05 4.55E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 5.22E-10 88 8.76E-01 58 8.79E-01 08 5.70E-01 03 3.28E-03 05 4.55E-02 I
3.45E-03 1
3.45E-03 1
1.00E+00 5.22E-10 88 8.78E-01 58 5.79E-01 58 0.790E-01 33 3.28E-03 05 4.55E-02 1
3.451-03 1
3.45E-03 1
1.00E+00 5.22E-10 88 8.76E-01 58 8.79E-01
SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.29E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 I
UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
130 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1AR FLAG - Service Water Pump PSWMlA Is In Operation 0.58 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 SWYMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/15 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
131 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.o8 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 UVREKIBX28 BUS 15 UNDERVOLTAGE RELAY 27BX2115 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27DI18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
132 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation 0.58 SWAASWP1CR FLAG - Service Water Pump PSW0IC Is In Operation D.58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 SWTMPUMPIB SW Pump B in maintenance 0.05 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI7B1 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
133 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 328E-03 SWTMPUMPI B SW Pump B in maintenance 0.05 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI7BDs BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1
134 TIO000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.282-03 SWTMPUMPIB SW Pump B in maintenance 0.05 UVRERG2718 BUS 18 UNDERVOLTAGE RELAY 27/11 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/t8 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
135 TIQ0OOSW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSWO1A is In Operation 0.58 SWAASWP1CR FLAG - Service Water Pump PSW0h1C Is In Operation 0.58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7BDS BUS 18 UNDERVOLTAGE RELAY 27D/Bs18 TRANSFERS TO DE-ENERGIZE3.94E-07 1
136 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 UVRERI7B1$
BUS 18 UNDERVOLTAGE RELAY 27B118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/I18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
137 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 SWMMOSWPDS FAILURES OF SW PUMP D TO START 3.28E-03 SWTMPUMP1B SW Pump B in maintenance 0.05 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27018/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1
UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27DI18 TRANSFERS TO DE-ENERGIZED 3.94Eo07 1
138 TIO000SW Total Loss of Service Water I
ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-06 1
ACCBR1829A AC BREAKER BUS18/29A TRANSFERS OPEN 1.33E-06 24 ACTRAINB TAG - Failure of AC Train B 1
DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice oand Loss of SW (3 0.02 139 T10000SW Total Loss of Service Water I
ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.0iE-08 1
ACCERI 829B AC BREAKER BUS18129B TRANSFERS OPEN 1.33E-06 24 ACTRAINB TAG - Failure of AC Train B 1
DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Casse Frazl ice and Loss of SW (3 0.02 140 TI0000SW Total Loss of Service Water 1
ACB2FIBS18 Local Fault on 480 VAC Bus 1 1.01 E-08 1
ACCBR1727A AC BREAKER BUS17/27A TRANSFERS OPEN 1.33E-06 24 ACTRAINA TAG - Failure of AC Train A I
DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (3 0.02 141 TI0000SW Total Loss of Service Water 1
ACB2FIBS18 Local Fault on 480 VAC Bus 18 1.01E-08 1
ACCBR1727B AC BREAKER BUS17/27B TRANSFERS OPEN 1.33E-08 24 ACTRAINA TAG - Fatlure of AC Train A I
DGAAINTAKE FLAG - MINIMUM OUTSIDE AIR TEMP IS < 30 DEGREES AND INTAKE HEATERS ENE 0.12 PCF PLANT CAPACITY FACTOR 0.88 SWAZINTAKE Assumption that Lake Temperature Is Cold Enough to Cause Frazil Ice and Loss of SW (3 0.02 142 TIODOOSW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWPPJIHDRB SERVICE WATER HEADER rB" PIPING RUPTURE 8.53E-07 1
SWTMPUMP1C SW Pump C in maintenance 0.04 143 TI0000SW Total Loss of Service Water I
POP PLANT CAPACITY FACTOR 0.88 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 SWPPJIHDRA SERVICE WATER HEADER A PIPING RUPTURE 5.53E-07 1
SWTMPUMPIC SW Pump C in maintenance 0.04 144 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 3.28E-03 4.55E-02 3.45E-03 3.45E-03 1.00E+00 5.22E-10 8.76E-01 5.79E-01 5.79E-01 3.28E-03 4.552-02 3.45E-03 3.45E-03 1.00E+00 5.22E-10 8.76E-01 5.79E-01 5.79E-01 3.28E-03 4.55E-02 3.45E-03 3.45E-03 1.00E+00 5.22E-10 8.76E-01 5.79Eo01 5.79E-01 3.28E-03 4.55E-02 3.45E-03 3.45E-03 1.00E+00 6.22E-10 8.76E-01 5.79E-01 5.79E-01 3.28E-03 4.55E-02 3.45E-03 3.45E-03 1.00E+00 5.22E-10 8.76E-01 5.79E-01 5.79E-01 3.28E-03 4.55E-02 3.45E-03 3.45E-03 1.002+00 5.221-10 8.76E-01 5.79E-01 5.79E-01 3.28E-03 4.55E-02 3.45E-03 3.45E-03 1.002+00 5.221-10 8.72E-01 5.79E-01 5.79E-01 3.28E-03 4.55E-02 3.45E-03 3.45E-03 1.00E+00 5.22E-10 8.78E-01 5.79E-01 5.79E-01 3.28E-03 4.552-02 3.45E-03 3.45E-03 1.00E+00 5.05E-10 8.85E-03 3.19E-05 1.002+00 1.23E-01 8.76E-01 1.86E-02 1.00E+00 5.05E-10 8.85E-03 3.19E-05 1.002+00 1.23E-01 8.76E-01 1.66E-02 1.00E+00 5.05E-10 8.85E-03 3.19E-05 1.00E+00 1.23E-01 8.78E-01 1.66E-02 1.001200 5.05-E10 8.85E-03 3.1 9E-05 1.00E+00 1.23E-01 8.78E-01 1.86E-02 1.00E+00 4.422-10 8.76E-01 5.79E-01 2.05E-04 2.47E-02 4.94E-03 3.58E-02 1.00E+00 4.42E-10 8.78E-01 5.79E-01 2.05E-04 2.47E-02 4.84E-03 3.50E-02 1.00E+00 4.09E-10 8.782-01 5.79E-01
SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMOSWPAS FAILURES OF SW PUMP A TO START 328E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1
3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 145 T10000SW Total Loss of Service Water I
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 6.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1
3.45E-03 UVREKt729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 146 Tt0000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.792-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1
3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 147 TI0000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-91 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 148 TIOO0OSW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.22E-03 3.28E-03 SWTMPUMP1C SW" Pump C in maintenance 0.04 3.56E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1
3.45E-03 UVRERt7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/8/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 149 TI000OSW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58
.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQO.94E-07 1
3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 10 TI0000SW Total Loss of Service Water 1
1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW012 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWThMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG0.94E-07 1
3.45E-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.04E-07 1
3.45E-03 151 T10000SW Total Loss ofServiceWater 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.792-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER/8.94E-07 I
3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 152 T10000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGE.94E-07 I
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 153 T10000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.as 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOlD Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERLN94E-07 I
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 154 TI0000SW Total Loss of Service Water 1
1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.w8 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.281-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.58E-02 UVREKI1729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 155 T10000SW Total Loss of Service Water I
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I
3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 156 T10000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG -Service Water Pump PSW1lD Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.562-02 UVREKI729C RELAY29-C IN BUS 17 UNDERVOLTAGE CIRCUITTRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.452-03 157 TI0000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.282-03 SWTMPUMPIC SW Pump C in maintenance 0.94 3.06E-02 UVREKI729D RELAY29-D IN BUS 17 UNDERVOLTAGE CIRCUITTRANSFERS TO ENER 3.94E-07 I
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 158 Ti0000m W Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.28E-03
SWTMPUMP1C SW Pump C In maintenance 0.04 3.56E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I
3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 I
3.45E-03 159 TIOO0OSW Tolal Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78G-01 SWAASWPIBR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 160 T10000SW Total Loss of Service Water I
1.00E+00 4.091-10 PCF PLANT CAPACITY FACTOR 0.88 8.76B-OI SWAASWP1BR FLAG - Service Water Pump PSWoB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMP1C SW Pump C In mainlenance 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 I
3.45E-03 161 1I0000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.285-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.9425-07 1
3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 I
3.45E-03 162 T10000SW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 I
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO D0-ENERGIZED 3.94E-07 1
3.45E-03 163 TI0OOOSW Total Loss of Service Water 1
1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG-Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.582-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO D0-ENERGIZED 3.94E-07 1
3.45E-03 164 T10000SW Total Loss of Service Water 1
1.0012+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is Io Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.58E-02 UVREKIlX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 165 TI0000SW Total Loss of Service Water I
1.002+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1S Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 156 TI0000SW Total Loss of Service Water 1
1.00+E00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWOI 0D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.282-03 SWTMPUMPIC SW Pump C In maintenance 0.04 3.56E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO D2-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.04E-07 1
3.45E-03 167 r0ooosW Total Loss of Service Water 1
1.00E+00 4.09E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWTrMPUMPIC SW Pump C in maintenance 0.04 3.56E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.942-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.452-03 168 TIOOOOSW Total Loss of Service Water 1
1.00E+00 4.0gE-10 PCF PLANT CAPACITY FACTOR 0.88 8.762-01 SWAASWPI6R FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.792-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 SWMlMOSWPAS FAILURES OF SW PUMP A TO START 3.282-03 3.28E-03 SWTMPUMP1C SW Pump C in maintenance 0.04 3.56E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7SD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 169 TIOOOOSW Total Loss of Service Water 1
1.0012+00 4.069-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.289-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 2.47E-02 SWTMPUMPID SW Pump 0 in maintenance 7.15E-03 7.15E-03 170 TI000OSW Total Loss of Service Water 1
1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ3.942-07 1
3.45E-03 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 171 710000SW Total Loss of Service Water 1
1.00E+00 3.95E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOiA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER3.94E-07 1
3.45E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.942-07 1
3.452-03 172 T10000SW Total Loss of Service Water 1
1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.14E-04 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E207 1
3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27X2)218 TRANSFERS TO ENERGIZED 3.04E-07 1
3.45E-03 173 T1000OSW Total Loss of Service Water 1
1.002+00 3.99E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01
SWAASWP1AR FLAG - SerAice Water Pump PSW01A Is In Operation SWAASNPICR FLAG - Service Water Pump PSWO1C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVRERI7B1 8 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 174 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWP1ICR FLAG - Service Water Pump PSWOIC Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERCM.94E-07 UVRER17BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 175 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW0lA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGM.94E-07 UVREKIB29C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 176 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWIC Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAG E CIRCUIT TRANSFERS TO ENERG8.94E-07 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 177 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 178 T0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWE1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG/.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/t8 TRANSFERS TO DE-ENERGIZED 3.94E-07 179 TIDOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWPICR FLAG-Service Water Pump PSW01C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start I
UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG(.94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 180 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation SWCCPUMPSS Common Cause Faiure Of Service Water Pumps To Start I
UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2J18 TRANSFERS TO ENERGIZED 3.94E-07 181 TIOO0OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI1AR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1
UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 182 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW1A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Stant UVREKI1829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7DI8 BUS 18 UNCERVOLTAGE RELAY 27D/1 8 TRANSFERS TO DE-ENERGIZED 3.94E-07 183 TI10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI828D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 184 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWIC Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI829D RELAY 29-C IN BUS 18 UNDiERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 185 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWIC Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start
- 1.
UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27D/a8 TRANSFERS TO DE-ENERGIZED 3.94E-07 188 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWCCPUMPSS Common Cause Falcre Of Service Water Pumps To Stan 1.1 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2118 TRANSFERS TO ENERGIZED 3.94E-07 187 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.1 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX218 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/1t TRANSFERS TO DE-ENERGIZED 3.94E-07 188 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWUIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start i.t UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2118 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 189 TI000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSWG1C Is In Operation
.14
.1 1.1 1.1 1.1 1.14 1.14 1.14
.14
.14l 14 141 141 14E.
14 40 0
0 0
0.58 5.79E-01 0.58 5.79E-01 14E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E-00 3.99E-10 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 141-04 1.14E-04 I
3.45E-03 I
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 4E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.78E-01 0.58 5.79E-01 4E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.768-01 0.58 5.798-01 0.58 5.79E-01 4E-04 1.14E-04 I
3.45E-03 I
3.45E-03 1
1.00E+00 3.99E810 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 4E-04 1.14E-04 1
3.45E-03 1
3.48E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.78E-01 0.58 5.78E-01 41-04 1.14E-04 I
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 4E-04 1.14E-04 1
3.45E-03 1
3.48E-03 1
1.00E+00 3.98E-10 0.88 8.78E-01 0.58 8.79E-01 0.58 8.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.008+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+O0 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 8.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 8.79E-01 0.58 8.79E-01 E-04 1.148-04 I
3.45E-03 1
3.458E-03 1
1.00E+00 3.99E-10 0.88 8.78E-01 1.58 5.79E-01 1.58 5.79E-01
'-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10
'.88 8.76E-01
.58 5.79E-01
.58 5.79E-01
-04 1.148-04 1
3.46E-03 1
3.45E-03 1
1.00E+00 3.99E-10
.88 8.78E-01
.588
.79E-01
.58 5.79E-01
SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 1.142-04 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 271h18 TRANSFERS TO DE-ENERGIZED 3.94E.07 I
3.4SE-03 190 TI0000SW Total Loas of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW0IC Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 UVRERr7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 191 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is tn Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 192 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWO0A Is In Operation SWAASWPICR FLAG - Servioe Water Pump PSWO1C Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D8/W18 TRANSFERS TO DE-ENERGIZE3.94E-07 193 TI0OOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWCCPUMPSS Common Cause Faflure Of Service Water Pumps To Start UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 194 Tf0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWCCPUMPSS Common Cause Faiure Of Service Water Pumps To Start UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27DM/18 TRANSFERS TO DE-ENERGIZE3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 2713/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 195 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER03.94E-07 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 196 110000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW0IB Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWO D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ8.94E-07 UVREKI729D RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 197 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWS18 Is In Operation SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG2.94E-07 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY27BX2/17TRANSFERS TO ENERGIZED 3.94E-07 198 TIOO0SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWO1 B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGS.94E-07 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 199 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWF1BR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation SWCCPUMPSS Common Cause Failure Of Serwice Water Pumps To Start UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/8/17 TRANSFERS TO DE-ENERGIZE3.94E-07 200 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW018 Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 201 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1
UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGM.94E-07 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 202 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1 BR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQB.94E-07 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 203 TISOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWDIB Is Ie Operation SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGt.94E-07 UVRERI7BI 7 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 204 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW9018 Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWS1D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQM.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B17 TRANSFERS TO DE-ENERGIZE3.94E-07 205 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIR FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start
- 1.
UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1.1 1.1 1.1 1.14
.14 1.14 1.14 1.14 1.14
.14
.14E
.14E
.141
.149.
142 142 I
1.00E200 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 4E-04 1.14E-04 1
3.45E-03 1
3.452-03 1
1.00E+00 3.90E-10 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 4E-04 1.14E-04 1
3.45E-03 I
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 4E-04 1.14E-04 I
3.45E-03 I
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 42-04 1.14E-04 I
3.45E-03 1
3.45E-03 1
1.002+00 3.99E-10 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 4E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.989E-10 0.88 8.78E-01 0.08 5.79E-01 0.58 5.79E-01 1E-04 1.14E-04 1
3.45E-03 I
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 2E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.792-01 0.58 5.79E-01 E-04 1.14E-04 1
3.45E-03 I
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.08 5.79E-01 E-04 1.14E-04 1
3.45E-03 I
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.88 5.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.89 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.002+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 E-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 E104 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10 0.88 8.76E-01 1.08 5.79E-01 1.58 5.79E-01
'-04 1.14E-04 1
3.45E-03 1
3.45E-03 1
1.00E+00 3.99E-10
.88 8.76E-01 0.58 5.79E-01
'.58 5.79E-01
--04 1.14E-04 1
3.45E-03
UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27)(21 17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 206 TI0000SW Total Loss of Service Water 1
1.00E-00 3.99E-10 PC, PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 SWAASWP1DR FLAG - Servlce Water Pump PSWOI D Is on Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
UVRER12717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
207 Tt0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWPI DR FLAG - Service Water Pump PSW01D Is Io Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27DI17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
208 T10000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I
UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1
209 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 SWAASWPI DR FLAG - Service Water Pump PSW1lD Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
210 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW01 B Is In Operatlon 0.58 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.141-04 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DO-ENERGIZED 3.94E-07 1
211 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPI BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 278X2/17 TRANSFERS TO ENERGIZED 3.94E-07 I
UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 I
212 T10000SW Total Loss of Service Water 1
POF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 SWAASWPIDR FLAG - Service Water Pump PSWO1 D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
213 T100OOSW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Stan 1.14E-04 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 I
UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
214 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWPI DR FLAG - Service Water Pump PSWM1D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI7817 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
215 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is tn Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27XV217 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
218 TIODOOSW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW(1B Is In Operation 0.58 SWAASWP1DR FLAG - Service Water Pump POW01D Is tn Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
217 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP11BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
218 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW018 Is In Operation 0.58 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7E17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
219 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPI BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWP1DR FLAG - Service Water Pump PSWID Is In Operation 0.58 SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start 1.14E-04 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 894E-07 1
UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D08117 TRANSFERS TO DE-ENERGIZE3.94E-07 1
220 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWMMSWPCRT FAILURES OF SI PUMP C TO RUN 2.05E-04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1
SWTMPUMP1A SW Pump A In maintenance 0.03 221 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 1
SWTMPUMPIA SW Pump A In mainlenance 0.03 222 T10000SW Total Loss of Service Water 1
5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.99E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.99E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E100 3.99E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.9ME-10
&76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3189E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.008E+
3.18E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.99E-10 8.78E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.99E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.99E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E.03 3.45E-03 1.00E+00 3.99E-10 8.78E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.99E-10 8.76E-01 5.791-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3199E-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E.03 1.00E+00 31991-10 8.76E-01 5.79E-01 5.79E-01 1.14E-04 3.45E-03 3.45E-03 1.00E+00 3.89E-10 8.76E-01 5.79E-01 2.47E-02 2.05E-04 4.84E-03 3.13E-02 1.00E+00 3.89E-10 8.76E-01 5.79E-01 2.05E-04 2.47E-02 4.84E-03 3.13E-02 1.00E+00 3.59E-10
PCF PLANT CAPACITY FACTOR 0.88
&78E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQO.94E-07 1
3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 223 T10000SW Total Loss of Service Water I
1.00E800 3.59E-iA PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1 BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWFP1DR FLAG -Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMM0SWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPtA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ2,94E-07 I
3.45E-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 224 TI0000SW Total Loss of Service Water I
1.O0E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWE 1D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI1729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 I
3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 225 TI0000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-Ol SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERC3.94E-07 1
3.48E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 226 Ti0000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW0t D Is In Operation 0.58 5.79E-81 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG2.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D8/117 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 227 TI0000SW Total Loss of Service Water 1
1.008+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0,58 5.7E-E01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3,94E-07 1
3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 228 TI8000SW Total Loss of Service Water 1
1.00E+00 3.598-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.138-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1
3.458-03 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 229 TI0000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERCE.94E-07 1
3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E807 1
3.45E-03 230 TIOSOCSW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 231 TI0000SW Total Loss of Service Water 1
1.008+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPiBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW010 Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E803 232 T10000SW Total Loss of Service Water 1
1.00E+00 3.598-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1 D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SVVWIPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 I
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X3217 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 233 TI000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SIN PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E.03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 234 TI0000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.78E801 SWAASWP 1DR FLAG - Service Water Pump PSWOtD Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.84E-07 1
3.45E-03 235 TI0000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWP1BR FLAG - Service Water Pump PSW015 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.798-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPlA SW Pump A in maintenance 0.03 3.13E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVREIIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 236 T10000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWS1B Is In Operation 0.58 5.79E-01
SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-1 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWIrMPUMPlA SW PumpA in maintenance 0.03 3.13E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRER12717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 237 T10000SW Total Loss of Service Water I
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 238 T10000SW Total Loss of Service Water I
1.002E00 3.59E.10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSWOIB Is nt Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 UVREKIB217 BUS 17UNDERVOLTAGE RELAY27BX2I17TRANSFERSTOENERGIZED 3.94E-07 1
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 239 TI0000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 6.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPOS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 240 T10000SW Total Loss of Service Water 1
1.00E200 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMMSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 241 T10000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1 DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SWPump A in maintenance 0.03 3.13E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7817 BUS 17 UNDERVOLTAGE RELAY 272/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 242 TI000OSW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 SWMMSSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI78D7 BUS 17 UNDERVOLTAGE RELAY 27D/0/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 243 TI0000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0o58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A In maintenance 0.03 3.13E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 272/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 244 T10000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW018 Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/A117 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 245 TI0OOOSW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.78E-01 SWAASWPIDR FLAG - Service Water Pump PSW010 Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMP1A SW Pump A In maintenance 0.03 3.13E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 246 T10000SW Total Loss of Service Water 1
1.00E+00 3.59E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWIB Is In Operation 0.58 5.79E-01 SWAASWPI DR FLAG - Service Water Pump PSW010 Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27DBI 7 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 247 TI0000SW Total Loss of Service Water 1
1.00E+00 3.24E-10 ACB2FIBS17 Local Fault on 480 VAC Bus 17 1.01E-08 1
8.85E-03 ACTRAINB TAG - Faium of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPART FAILURES OF SERV1CE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 2.05E-04 248 T10000SW Total Loss of Service Water I
1.00E+00 3.202-10 ACB2FIBS1B Local Fault on 480 VAC Bus 18 1.012-06 1
8.85E-03 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.05E-04 249 TI0000SW Total Loss of Service Water 1
1.002+00 2.58E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMSWPARI FAILURES OF SERVtCE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMP1D SIN Pump D in maintenance 7.15E-03 7.15E-03 250 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Falure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1
3.45E-03 IVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 251 710000SW Total Loss of Service Water 1
1.00E+00 2.64E-10
ACB2FTBSI 7 Local Fault on 480 VAC Bus 17 1.0112-06 72 7.27E-05 ACTRAINB TAG - Fauure of AC Train B 1
1.0E000 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW0IC Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1
3.45E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 252 TI0000SW Total Loss of Service Water 1
1.00E+00 2.542-10 ACE2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG1.94E-07 1
3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 253 TIQOCOSW Total Loss of Service Water 1
1.00E200 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.002E00 PCF PLANT CAPACITY FACTOR 0.88 8.79E-01 SWAASWPIAR FLAG - Service Water Pump PSWD1A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 1
3.45E-03 UVRERI7B18 BUS 19 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 254 TIOOOSW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.79E-01 SWAASWPIAR FLAG - Service Water Pump PSWD1A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGa.94E-07 1
3.45E-03 UVRERI7BD9 BUS 18 UNDERVOLTAGE RELAY 270/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 255 T10000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88
&76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGE.94E207 1
3.45E-03 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 256 T10000SW Total Loss of Service Water 1
1.02E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E201 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGa.94E-07 I
3.45E-03 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 257 T10000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1
3.45E-03 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 I
3.45E-03 258 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Fuilure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.792-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQE.94E-07 1
3.45E-03 UVRERI7BI8 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 259 TIOOOSSW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 489 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWS1C Is In Operation 0.58 5.79E-01 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQM.94E-07 1
3.45E-03 UVRERI7BDS BUS 18 UNDERVOLTAGE RELAY 27018/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 260 TIOOOOSW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 489 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.79E201 SWAASWP1AR FLAG - Service Water Pump pSWO1A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY27X2118 TRANSFERSTO ENERGIZED 3.94E-07 1
3.45E-03 261 TIOOOOSW Total Loss of Service Water 1
1.001+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.08E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 262 T10000SW Total Loss of Service Water I
1.00E+00 2.54E.10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 263 T10000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.012E-0 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C is in Operation 0.58 5.79E-01 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 264 T10000SW Total Loss of Service Water 1
1.00E+00 2.64E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.002+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE0ENERGIZED 3.94E-07 1
3.45E-03 265 TIO0SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00
PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI71318 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 266 TI00OOSW Total Loss of Service Water 1
1.00+200 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failurm of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump P-W01A Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 287 TI0000SW Total Loss of Service Water I
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train 8 1
1.00E+80 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1AR FLAG - Service Water Pump PSWOIA Is In Operation 0.88 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 278X2118 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 268 710000SW Total Loss of Service Water I
1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7DI8 BUS 18 UNDERVOLTAGE RELAY 27D1/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 269 TI0000SW Total Loss of Service Water I
1.00E+00 2.54E-10 ACB2FTES17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINS TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 I
3.45E-03 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 270 T10000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBSI7 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.001200 PCF PLANT CAPACITY FACTOR 0.88 8.788-01 SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation 0.58 5.79E-01 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D0B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 271 TI000OSW Total Loss of Service Water I
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation 0.58 5.78E-01 SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BI8 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 272 TI0000SW Total Loss of Service Water I
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault an 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINE TAG - Failure of AC Train 5 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 273 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-08 72 7.27E-05 ACTRAINB TAG - Failure ofAC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.58 5.79E-01 SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B118 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E803 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/I8 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.48E-03 274 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS17 Local Fault on 480 VAC Bus 17 1.01E-06 72 7.27E-05 ACTRAINB TAG - Failure of AC Train B 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIAR FLAG - Service Water Pump PSWSIA Is In Operation 0.58 3.79E-01 SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation 0.58 5.79E-01 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/8118 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 275 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E.10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Falure of AC Train A 1
1.002E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW0lD Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 1
3.45E-03 UVREKI7290 RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.458E-03 278 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.008+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 I
3.45E-03 UVREKI17290 RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 277 TISOSOSW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus lB 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOI B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 1
3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 278 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27817 TRANSFERS TO DE-ENERGIZED 3.94E-07 I
3.45E803 279 TIOO00SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIBR FLAG - Service Water Pump PSWO18 Is In Operation 0.58 5.79E-01
SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 I
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B117 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-03 280 TI000OSW Total Loss of Service Water 1
1.00E-00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01 B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWI1D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1
3.45E-03 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 281 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS1B Local Fault on 490 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSWO1 B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1
3.45E-03 UVREKI1729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 282 TI0000SW Total Loss of Service Water I
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPI BR FLAG - Service Water Pump PSWOI B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 1
3.45E-03 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 283 TI0000SW Total Loss of Service Water I
1.00E+00 2.54E-10 AC82FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A I
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSWO0D Is In Operation 0.58 5.79E-01 UVREKI7295 RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 284 TI0000SW Total Loss of Service Water I
1.00E+00 2.54E.10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 727E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E÷00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI BR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D0/B17 TRANSFERS TO DE-ENERGIZE3.94E-07 I
3.45E-03 285 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E010 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.001+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW01B I In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 2712/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 288 TIC0OSW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.790E01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DEO-ENERGIZED 3.94E-07 1
3.45E-03 287 T10000SW Total Loss of Service Water I
1.900E00 2.540-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSW801 Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D1l17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 288 TI000SW Total Loss of Service Water I
1.00E0+0 2.54E-10 ACB2FTESI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 579E-01 SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation 0.58 5.79E-01 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X217 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 289 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW0IB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 UVREKI728D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 290 TI0000SW Total Loss of Service Water I
1.00E+00 2.64E.10 ACB2FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88
&76E-01 SWAASWP1BR FLAG - Service Water Pump PS601B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
3.45E-03 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 291 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBSI Local Fault on 480 VAC Bus 13 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E001 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 292 TI0000SW Total Loss of Service Water 1
1.00.E00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus I8 1.01E-08 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWP1 BR FLAG - Service Water Pump PSWB01B In to Operation 0.58 5.79E-01 SWAASWPIDR FLAG-Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 293 T10000SW Total Loss of Service Water I
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.010-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 6.78E-01 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03
UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 294 TI0000SW Total Loss of Servioe Water I
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7B17 BUS 1 7
UNDERVOLTAGE RELAY 27B/17I*.ANSFERS TO DE-ENERGIZED 3.948-07 1
3.45E-03 295 T10000SW Total Loss of Service Water 1
1.008200 2.54E-10 ACB2FTBS1B Local Fault on 480 VAC Bus 18 1.01E-00 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI8R FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 5.79E-01 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27018/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
3.45E-OS 298 TI0000SW Total Loss of Service Water 1
1.00E-00 2.64E.10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPI8R FLAG - Service Water Pump PSWO1B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation 0.58 5.79E-01 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 297 T10000SW Total Loss of Service Water 1
1.0012.00 2.54E-10 ACB2FTBSI8 Local Fault on 480 VAC Bus 18 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.768E-01 SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW0lD Is In Operatioo 0.58 5.79E-01 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D0B/I 7 TRANSFERS TO DE-ENERGIZE3.94E.07 1
3.45E-03 298 TI0000SW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 1 8 1.01E-06 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88 8.768E-01 SWAASWPIBR FLAG - Service Water Pump PSW01B is In Operation 0.58 5.79E-01 SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 UVRERI7817 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
3.45E-03 299 TIO0OOSW Total Loss of Service Water 1
1.00E+00 2.54E-10 ACB2FTBS18 Local Fault on 480 VAC Bus 18 1.01E-00 72 7.27E-05 ACTRAINA TAG - Failure of AC Train A 1
1.00E+00 PCF PLANT CAPACITY FACTOR 0.88
&76E-01 SWAASWP1BR FLAG - Service Water Pump PSW001B Is In Operation 0.58 5.79E-01 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 5.79E-01 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94 E-07 1
3.45E-03 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E.07 1
3.45E-03 300 TI0000SW Total Loss of Service Water 1
1.008+00 2.428-10 PCF PLANT CAPACITY FACTOR 0.68 8.70E-01 SWAASWPI1R FLAG - Service Water Pump PS01B Is In Operation 0.88 5.78E-01 SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWMMSWPBRI FAILURES OF SW PUMP S TO RUN 0.02 2.47E-02 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.051-04 2.05E-04 SWTMPUMP1A SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMPID SW Pump D in maintenance 7.15E-03 7.108-03 301 TI00DOSW Total Loss of Service Water 1
1888.00 2.38-10 PCF PLANT CAPACITY FACTOR 088 8.78E-01 SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation 0.42 4.21E-01 SWAASWP1CR FLAG - Service Water Pump PSWIC Is In Operation 0.58 5.79E-01 SWMMSWPBRT FAILURES OF SW PUMP S TO RUN 2.02E-04 2.02E-04 SWMVMSWPCRI FAILURES OF SW PUMP C TO RUN 0.02 2.47E-02 SWTMPUMPIA SW Pump A in maintenance 0.03 3.13E-02 SWTMPUMP1D SW Pump D in maintenance 7.15E-03 7.15E-03 302 TI0000SW Total Loon of Service Water 1
1.008+00 1.61E-10 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSW081B Is Not In Operatioa 0.42 4.21E-01 SWAASWPIDR FLAG - Service Water Pump PSW0lD Is In Operation 0.58 5.79E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.058-04 2.858-84 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN
.082 2.47E-02 SWTMPUMPIB SW Pump B in maintenance 0.05 4.55E-02 303 TI0000SW Total Loos of Service Water 1
1.00E-00 1.61E-t0 PCF PLANT CAPACITY FACTOR 0.88 8.76E-01 SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 4.21E-01 SWAASWP1DR FLAG - Service Water Pump PSW601D Is In Operation 0.58 5.79E-01 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWMIMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 2.05E-04 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 2.47E-02 SWTMPUMP1B SW Pump B in maintenance 0.05 4.55E-02 304 T100005W Total Loss of Service Water 1
1.00+00 1.388-to PCF PLANT CAPACITY FACTOR 0.88 8.78E-01 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 4.21E-01 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 3.28E-03 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 3.28E-03 SWPPJIHDRA SERVICE WATER HEADER "A PIPING RUPTURE 5.53E-07 1
4.84E-03 SWTMPUMP1D SWIPump D In malatenance 7.15E-03 7.158-03 305 TIOOOSW Total Loss of Service Water 1
1.008+80 1.268-10 PCF PLANT CAPACITY FACTOR 0.88
.70 16E-01 SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.88 5.79E-01 SWAASWP1CNR FLAG - Service Water Pump PSWOIC Is Not In Operation 0.42 4.21E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMtSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.05E-04 2.058-04 SWTMPUMP1C SW Pump C in maintenance 0.84 3.568-02 306 T10000SW Total Loss of Service Water 1
1.001+00 1.248-10 PCF PLANT CAPACITY FACTOR 0.88 8.768E-01 SWAASWPIAR FLAG - Service Water Pump PSW0IA Is In Operation 0.58 5.79E-01 SWAASWPICNR FLAG - Service Water Pump PSWOIC Is Not Io Operation 0.42 4.21E-01 SWMM8SWPDS FAILURES OF SW PUMP D TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPBRT FAILURES OF SW PUMP B TO RUN 2.02E-04 2.02E-04 SWTMPUMPiC SW Pump C In maintenance 0.84 3.568-02 307 T10000SW Total Loss of Service Water 1
1.00E+00 1.20E-18 PCF PLANT CAPACITY FACTOR 8.88 6.760 1E SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation 0.88 5.798E-01 SWAASWPlCR FLAG - Service Water Pump PSW01C Is In Operation 0.58 5.79E-01 SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.28E-03 3.28E-03 SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN 0.02 2.47E-02 SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 8.02 2.478-02 SWMMSWPDRT FAILURES OF SW PUMP D TO RUN 2.085-04 2.058-04 308 TI000OSW Total Loss of Service Water 1
1.00E+00 1.308-to PCF PLANT CAPACITY FACTOR 0.88 8.76E-01
SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSM01D Is In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWMMSWPCRT FAILURES OF SW PUMP C TO RUN SWMMSWPORI FAILURES OF SW PUMP D TO RUN 309 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW0I D Is In Operation SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPSRI FAILURES OF SW PUMP S TO RUN SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 310 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMIMSWPBRT FAILURES OF SW PUMP S TO RUN SWMMSWPCRI FAILURES OF SW PUMP C TO RUN 311 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWTMPUMP1A SW Pump A in maintenance 312 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPBRT FAILURES OF SW PUMP B TO RUN SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMPIA SW Pump A in maintenance 313 TI0O0OSW Total Loss of Service Water ACB2FIBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWIMPUMPtA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance 314 TI0000SW Total Loss of Service Water ACB2FIBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWTMPUMP1S SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance 315 TI0000SW Total Loss of Service Water ACB2FTBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW0IA Is Not In Operation SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMPIC SW Pump C in maintenance 318 TI0OOOSW Total Loss of Service Water ACB2FTBS17 Local Fault on 480 VAC Bus 17 ACTRAINB TAG - Failure of AC Train B PCF PLANT CAPACITY FACTOR SWPPJIHDRA SERVICE WATER HEAOER "A" PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER "B5 PIPING RUPTURE 317 T10000SW Total Loss of Service Water ACB2FTES18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWAASWPI BNR FLAG - Service Water Pump PSW01lB Is Not In Operation SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation SWTMPUMP1B SW Pump S in maintenance SWTMPUMPI D SW Pump D in maintenance 318 TIOE00SW Total Loss of Service Water ACB2FTBS18 Local Fault on 480 VAC Bus 18 ACTRAINA TAG - Failure of AC Train A PCF PLANT CAPACITY FACTOR SWPPJIHORA SERVICE WATER HEADER A" PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER "S" PIPING RUPTURE 319 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CNR FLAG-Service Water Pump PSW01C Is Not In Operation SWCCPUMPSS Common Cause Failura Of Service Water Pumps To Start SWIMPUMPIA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance 320 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSWO1A Is Not In Operation SWAASWP1CNR FLAG - Service Water Pump PSW0IC Is Not In Operation SWMMOSWPBS FAILURES OF SW PUMP S TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMP1A SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance 321 TI00QSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWPICNR FLAG - Service Water Pump PSWO1 C Is Not In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWrMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance 322 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START SWTMPUMP1A SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance SWTMPUMPI D SW Pump D in maintenance 323 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSWE1A Is Not In Operation SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMM0SWPDS FAILURES OF SW PUMP D TO START 0.58 0.58 3.28E-03 0.02 2.05E-04 0.02 1
0.88 0.58 0.58 3.28E-03 2.05E-04 0.02 0.02 I
0.88 0.58 0.58 3.28E-03 0.02 2.02E-04 0.02 1
0.88 0.42 0.58 3.28E-03 0.02 2.05E-04 0.03 1
0.88 0.42 0.58 3.28E-03 2.02E-04 0.02 0.03 1
1.01E-06 1
I 0.88 0.03 0.04 1
1.01E-06 1
1 0.88 0.05 7.15E-03 1
1.01E-06 72 0.88 0.42 0.42 0.03 0.04 I
1.01E-06 72 1
0.88 5.53E-07 1
5.53E-07 1
1 1.011-06 72 1
0.88 0.42 0.42 0.05 7.15E-03 I
1.01E-08 72 1
0.88 5.53E-07 I
5.53E-07 1
I 0.88 0.42 0.42 1.14E-04 0.03 0.04 1
0.88 0.42 0.42 3.28E-03 3.28E-03 0.03 0.04 1
0.88 0.42 0.42 3.28E-03 2.05E-04 0.03 0.04 1
0.88 0.42 0.42 3.28E-03 0.03 0.04 7.115E-03 0.88 0.42 0.42 3.28E-03 5.79E-01 5.79E-01 3.28E-03 2.47E-02 2.05E-04 2.47E-02 1.00E+00 1.20E-10 8.76E-01 5.79E-01 5.79E-01 3.28E-03 2.05E-04 2.47E-02 2.47E-02 1.000+00 1.19E-10 8.76E-01 5.79E-01 5.790E-01 3.28E-03 2.47E-02 2.02E-04 2.47E-02 1.00E+00 1.11E-10 8.76E-01 4.21E-01 5.79E-01 3.28E-03 2.47E-02 2.05E-04 3.13E-02 1.00E+00 1.09E-10 8.76E-01 4.21E-01 5.79E-01 3.28E-03 2.02E-04 2.47E-02 3.13E-02 1.00E+00 0.80E+00 8.85E-03 1.00E+00 8.78E-81 3.113E-02 3.56E-02 1.00E+00 O.00E+00 8.815-03 1.00E+00 8.76E-01 4.55E-02 7.15E-03 1.00E+00 0.000E00 727E-05 1.00E+00 8.76E-01 4.21E-01 4.21E-01 3.13E-02 3.56E-02 1.00E+00 8.00E+00 7.27E-05 1.00E+00 8.76E-01 4.84E-03 4.84E-03 1.00E+00 O.00E+00 7.27E-05 1.00E+00 8.78E-01 4.21 E-01 4.21E-01 4.55E-02 7.15E-03 1.00E+00 0.00E+00 7.278&O5 1.00E+00 8.76E-01 4.84E-03 4.84E-03 1.00E+00 0.00E+00 876E-01 4.211-01 4.21E-01 1.14E-04 3.13E-02 3.56E-02 1.00E+00 0.00E+00 8.76E-01 4.21E-01 4.21E-01 3.28E-03 3.28E-03 3.13E-02 3.56E-02 1.00E+00 0.00E+00 8.76E-01 4.21E-01 4.21E-01 3.28E-03 2.05E-04 3.130-02 3.561-02 1.00E+00 0.OOE+00 8.76E-01 4.21E-01 4.21E-01 3.28E-03 3.131-02 3.56E-02 7.15E-03 1.008200 O.00E+00 8.76E-01 4.21E-01 4.21E-01 3.28E-03
SWMMSWPBRT FAILURES OF SW PUMP B TO RUN SWTMPUMP1A SW Pump A in maiotenance SWTMPUMPIC SW Pump C in maintenance 324 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1S SW Pump S in maintenance SWTMPUMPIC SW Pump C in maintenance 325 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMSWPBRT FAILURES OF SW PUMP B TO RUN SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance SWTMPUMPID SW Pump D in maintenance 326 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CNR FLAG - Ser.vce Water Pump PSWOIC Is Not In Operation SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1e SW Pump S in maintenance SWTMPUMPIC SW Pump C in maintenance 327 710000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSWO1A Is Nat In Operntion SWAASWPICNR FLAG - Service Water Pump PSWOIC Is Not In Operation SWTMPUMP1A SW Pump A In maintenance SWTMPUMPIS SW Pump S in maintenance SWTMPUMPIC SW Pump C in maintenance SWTMPUMP1D SW Pump D in maintenance 328 T000OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CR FLAG - Service Water Pump PSWEIC Is In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMPIA SN Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance 329 TI000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWAASWP1CR FLAG - Service Water Pump PSW0IC Is In Operation SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance 330 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not un Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1B SW Pump S in maintenance SWTMPUMPI D SW Pump D in maintenance 331 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWMMOSWPDS FAILURES OF SW PUMP D TO START SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1B SW Pump S in maintenance 332 TIOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIANR FLAG - Service Water Pump PSW01A Is Not In Operation SWMMSWPDRT FAILURES OF SW PUMP C TO RUN SWPPJIHDRS SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance 333 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1ANR FLAG - Service Water Pump PSW01A Is Not In Operation SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIB SW Pump S in maintenance SWTMPUMPID SW Pump D in maintenance 334 TI000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWPICNR FLAG - Service Water Pump PSWOIC Is Not In Operation SWMMOSWPSS FAILURES OF SW PUMP B TO START SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWIMPUMPIC SW Pump C in maintenance SWTMPUMPID SW Pump D in maintenance 335 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWP1CNR FLAG - Service Water Pump PSWMIC Is Nut In Operation SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPBRT FAILURES OF SW PUMP B TO RUN SWTMPUMPiC SW Pump C in maintenance SWTMPUMPID SW Pump D in maintenance 336 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWP1CNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWTMPUMP1 B SW Pump B in maintenance SWTMPUMP1C SW Pump C In maintenance SWTMPUMP1D SW Pump D in maintenance 337 TI7OOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOtA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWMMSWPARI FAILURES OF SERVICE WATER PUMP A TO RUN SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWTMPUMPIS SW Pump B in maintenance SWrMPUMPID SW Pump D in maintenance 338 TIOOSOW Total Loss of Service Water PCF PLANT CAPACITY FACTOR 2.02E-04 0.03 0.04 1
0.88 0.42 0.42 3.28E-03 0.03 0.05 0.04 1
0.88 0.42 0.42 2.02E-04 0.03 0.04 7.15E-03 I
0.88 0.42 0.42 2.05E-04 0.03 0.05 0.04 1
0.88 0.42 0.42 0.03 0.05 0.04 7.15E-03 I
0.88 0.42 0.58 3.28E-03 0.02 0.03 0.05 1
0.88 0.42 0.58 0.02 2.05E-04 0.03 0.05 1
0.88 0.42 0.58 0.02 0.03 0.05 7.15E-03 1
0.88 0.42 3.28E-03 5.53E-07 1
0.03 0.05 1
0.88 0.42 2.05E-04 5.53E-07 1
0.03 0.05 I
0.08 0.42 5.53E-07 I
0.03 0.05 7.15E-03 1
0.88 0.58 0.42 3.28E-03 0.02 0.04 7.15E-03 0
0.88 0.58 0.42 0.02 2.02E-04 0.04 7.151-03 1
0.88 0.58 0.42 0.02 0.05 0.04 7.15E-03 1
0.88 0.58 0.58 0.02 0.02 0.05 7.15E-03 0
0.88 2.02E-04 3.13E-02 3.56E-02 1.OOE+n0 0.00+E00 8.76E-01 4.21E-01 4.21E-01 3.28E-03 3.13E-02 4.55E-02 3.56E-02 1.00E+00 0.00E+00 8.78E-01 4.21E-01 4.21E-01 2.02E-04 3.13E-02 3.56E-02 7.15E-03 1.000+00 O.00E+00 0.76E-01 4.21E-01 4.21E-01 2.05E-04 3.13E.02 4.65E-02 3.5612-02 1.00E+00 0.00E+00 8.70E-01 421E-01 4.21E-01 3.13E-02 4.55E-02 3.56E-02 7.15E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.28E-03 2.47E-02 3.13E-02 4.55E-02 1.00E+00 0.000+00 8.76E-01 4.21E.01 5.79E-01 2.47E-02 2.051-04 3.13E-02 4.55E-02 1.00E+00 0.000+00 8.76E-01 4.21E-01 5.79E-01 2.47E-02 3.13E-02 4.55E-02 7.151-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 3.28E-03 4.84E-03 3.13E-02 4.55E-02 1.00E+00 0.00E+00 8.76E-01 4.21E-01 2.05E-04 4.84E-03 3.13E-02 4.55E-02 1.000+00 0.0OE+00 8.76E-01 4.21 E-01 4.54E-03 3.13E-02 4.55E-02 7.15E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 4.21E-01 3.28E-03 2.47E-02 3.56E-02 7.15E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 4.21E-01 2.47E-02 2.02E-04 3.56E-02 7.15E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 4.21E-01 2.47E-02 4.55E-02 3.56E-02 7.150-03 1.00E+00 0.000E00 8.76E-01 5.79E-01 5.79E-01 2.47E-02 2.47E-02 4.55E-02 7.15E-03 1.00E+00 0.00E+00 8.76E-01
SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGaB4E-07 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 339 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01EC Is In Operation SWTMPUMPI B SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 340 TIO0OOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance UVREKIB29A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 341 TIO000SW Total Loon of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW1iA Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWTIMPUMPIB SW Pump B in maintenance SWTMPUMPI D SW Pump D in maintenance UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ2.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 2713/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 342 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01iC Is In Operation SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance 7
UVREKI829A RELAY 29-A IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERCS.94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/S/18 TRANSFERS TO DE-ENERGIZE 3.94E-07 343 TIOO0OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWTIMPUMPIB SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance
- 7.
UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGB.94E-07 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 344 TI0000SW Total Loso of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW8/1A Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMP1B SN Pump B In maintenance SWTMPUMP1D SW Pump D in maintenance
- 7.
UVREKI829B RELAY 29-B IN BUS lB UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVREKI828D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 345 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMPIB SW Pump B in maintenance SW/TMPUMPID SIN Pump D in maintenance 7:
UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGB.94E-07 UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2118 TRANSFERS TO ENERGIZED 3.94E-07 346 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW1iC Is In Operation SWTMPUMP1B SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance 7.1 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 347 TI0OOISW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWOIA Is in Operation SWAASWPICR FLAG - Service Water Pump PSW0IC Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance 7.1 UVREKI829B RELAY 29-B IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG,94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 348 TI00OESW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW1IA Is In Operation SWAASWPICR FLAG-Service Water Pump PSWSiC Is In Operation SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance 7.15 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27)(2/18 TRANSFERS TO ENERGIZED 3.94E-07 349 TIOOO0SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01IC Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance 7.15 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 350 TI000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWO1C In In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance 7.15 UVREKI829C RELAY 29-C IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO D0-ENERGIZED 3.94E-07 351 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPlAR FLAG - Service Water Pump PSW0IA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance 7.1 UVREIO829D RELAY 29-DIN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2J18 TRANSFERS TO ENERGIZED 3.94E-07 352 T1000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWIA Is In Operation 0
SWAASWP1CR FLAG - Service Water Pump PSW01C Is In Operation 0
7.1 7.1 7.1 7.15
.15E 15; 198 0
0
- 0.
0SE
- 0.
- 0.
- 0.
- 0.
58 0.8 0.1 0.1 0.C SB
- 0.
0.5 0.5 0.0 E-0 0.8 D.51 0.8 0.88 0.&8 0.58 0.08 E-03 1
0.88 0.58 L58 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 15&-03 7.15E-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 8.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 8E-03 7.15E-03 1
3.45E-03 I
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 5E-03 7.15E-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 E-03 7.151-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 E-03 7.15E-03 I
3.45E-03 1
3.458E-03 1
1.00E+00 0.001+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 E-03 7.15E-03 I
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.761-01 0.58 8.79E-01 0.58 5.79E-01 0.05 4.55E-02
,-03 7.15E-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01
'.58 5.79E-01
.58 5.79E-01
'.05 4.55E-02
-03 7.15E-03 I
3.45E-03 1
3.45E-03 1
1.001+00 0.00E+00 8.8 8.76E-01
.58 5.798-01
.58 5.79E-01
.05 4.55E-02 4D3 7.15E-03 1
3.45E-03 I
3.45E-03 1
1.00E+00 0.00E+00 88 8.78E-01 58 5.79E-01 on 5.79E-01 05 4.55E-02 33 7.15E-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 O.00E+00 B8 8.76E-01 se 5.79E-01 58 5.79E-01 05 4.55E-02 O
7.15E-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 S
8.76E-01 5
5.79E-01 8
5.79E-01 5
4.55E-02 3
7.15E-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 8
8.76E-01 58.79E-01 8
5.79E-01 5
4.55E-02 1
7.15E-03 I
3.45E-03 S
3.45E-03 1.00E+00 O.OOE+80 8
8.78E-01 I
5.79E-01 5.79E-01 4.55E-02 7.15E-03 3.45E-03 3.45E-03 1.00E+80 0.00E+00 8.76E-01 5.79E-01 5.79E-01
SWTMPUMPI B SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance UVREKI829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E.07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 353 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWO1C Is In Operation SWTMPUMP1B SW Pump B In maintenance SWTMPUMP1D SW Pump D in maintenance UVREK1829D RELAY 29-D IN BUS 18 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 354 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWO1C Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMPI D SW Pump D In maintenance UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27",2/18 TRANSFERS TO ENERGIZED 3.94E-07 355 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is in Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWThIPUMPIB SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 356 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWPlCR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance UVREKIBX28 BUS 18 UNDERVOLTAGE RELAY 27BX2/18 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI7Dt8 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 357 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation SWTMPUMP1B SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E.07 UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 27B/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 358 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWOIA Is In Operation SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance UVREKIX218 BUS 18 UNDERVOLTAGE RELAY 27X2/18 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI7BD8 BUS 18 UNDERVOLTAGE RELAY 27D/B/18 TRANSFERS TO DE-ENERGIZE3.94E-07 359 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWOIC Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7818 BUS 18 UNDERVOLTAGE RELAY 271/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 360 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWS1A Is In Operation SWAASWP1CR FLAG - Service Water Pump PSWOIC Is In Operation SWTMPUMPIB SW Pump B in maintenance SWTMPUMPID SW Pump D in maintenance 7
UVRERI2718 BUS 18 UNDERVOLTAGE RELAY 27118 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7008 BUS 18 UNDERVOLTAGE RELAY 27D/B118 TRANSFERS TO DE-ENERGIZE3.94E-07 361 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1AR FLAG - Service Water Pump PSW01A Is In Operation SWAASWPICR FLAG - Service Water Pump PSWSIC Is In Operation SWTMPUMPI SW Pump B in maintenance SWTMPUMPID SW Pump D In maintenance 7
UVRERI7B18 BUS 18 UNDERVOLTAGE RELAY 278/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 270/18 TRANSFERS TO DE-ENERGIZED 3.94E-07 382 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSW01A Is In Operation SWAASuWPICR FLAG - Service Water Pump PSW01C Is In Operation SWTMPUMP18 SW Pump B in maintenance SWTMPUMP1D SW Pump D In maintenance
- 7.
UVRERIJBD8 BUS 18 UNDERVOLTAGE RELAY 27D/8118 TRANSFERS TO DE-ENERGIZE3.94E-07 UVRERI7D18 BUS 18 UNDERVOLTAGE RELAY 27D/18 TRANSFERS TO DE-ENERGIZED 3.04E-07 363 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIAR FLAG - Service Water Pump PSWO1A Is In Operation SWMMSWPARI FAILURES OF SERVTCE WATER PUMP A TO RUN SWPPJIHDRB SERVICE WATER HEADER WB`
PIPING RUPTURE 5.53E-07 SWTMPUMP1B SW Pump B in maintenance SWTMPUMPID SW Pump D In maintenance
- 7.
384 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSWOIB Is Not In Operation SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation SWCCPUMPSS Common Cause Failure Of Service Water Pumps To Start I
SWTMPUMP1E SW Pump B in maintenance SWTMPUMP1D SW Pump D In maintenance
- 7.
365 TIOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWP1DNR FLAG - Service Water Pump PSWO1D Is Not In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.:
SWMM0SWPCS FAILURES OF SW PUMP C TO START
- 3.
SWTMPUMPI B SW Pump B In maintenance SWTMPUMP10 SW Pump D in maintenance 7.1 386 810000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPIDNR FLAG - Service Water Pump PSW0ID Is Not In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.2 SWTMPUMPIB SW Pump B in maintenance SWTMPUMP1C SW Pump C in maintenance SWTMPUMP1D SW Pump D in maintenance 7.1
- 7.
7.1 7.1 7.1 7.1.
7.15 7.15 ris 7.15 7.15E
.151 158 14SE 15E 0
0 0
18*
08I 0
158 0
0 0
0
- 0.
- 0.
15E 0.05 4.55E-02 ISE-03 7.15E-03 1
3.45E.03 1
3.45E-03 I
1.00E+00 0.00E+00 0.88 8.78E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E.02 5E-03 7.15E-03 I
3.45E-03 1
3.45E-03 1
1.008200 0.00E+00 0.88 8.78E.01 0.58 5.79E-01 0.58 5.79E.01 0.05 4.55E-02 5E-03 7.158-03 1
3.45E-03 I
3.45E-03 1
1.00E+00 0.0012+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 5E-03 7.15E-03 I
3.45E-83 1
3.45E-03 1
1.00E+00 0.00+E00 0.88 8.76E-01 0.58 5.79E.01 0.58 5.79E-01 0.05 4.58E-02 5E-03 7.15E-03 1
3.45E-03 I
3.458E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 5E-03 7.15E.03 1
3.45E-03 1
3.45E-03 I
1.00E+00 0.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 E-03 7.15E-03 1
3.45E-03 I
3.45E-03 1
1.008+00 0.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 E-03 7.15-E03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.008+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.58E-02 E-03 7.18-E03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.58 5.79E-01 0.58 5.79E-01 0.05 4.55E-02 E-03 7.18E-03 1
3.45E-03 I
3ASE-03 1
1.00E+00 0.00E+00 0.88 8.70E-01 0.58 5.79E-01 0.58 5.79E801 0.05 4.55E-02 i-03 7.15E-03 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.58 5.79E-01 1.02 2.47E-02 1
4.84E-03 1.05 4.55E-02
-03 7.158E-03 1
1.00E+00 0.00E+00 1.88 8.76E-01 1.42 4.21E-01
.42 4.21E-01
-04 1.14E-04 0.05 4.55E-02
"-03 7.15E-03 1
1.00E+00 0.00+E00
.88 8.76E-01
.42 4.21E-01
.42 4.21E-01
"-03 3.28E-03
-03 3.288-03
.05 4.55E-02
-03 7.15E-03 1
1.00E+00 0.00E+00
.88 8.76E-01
.42 4.21E-01
.42 4.21E-01
-03 3.28E-03
.05 4.88E-02
.04 3.50E-02
-03 7.15E-03
367 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI BNR FLAG - Service Water Pump PSMIB Is Not In Operation SWAASWP1DNR FLAG - Service Water Pump PSW01 Is Not In Operation SWMMOSWPCS FAILURES OF SW PUMP C TO START SVWI7MPUMPFA SW PUMp A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1D SW Pump D in maintenance 368 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN SWTMPUMPIB SW Pump B in maintenance SWTMPUMPIC SWN Pump C in maintenance SWTMPUMPID SW Pump D in maintenance 369 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation SWAASWP1DNR FLAG - Service Water Pump PSW01D Is Not In Operation SWMMSWPCRT FAILURES OF SW PUMP C TO RUN SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIB SW Pump B1in maintenance SWTMPUMPiD SW Pump D in maintenance 370 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1C SW Pump C in maintenance SWTMPUMP1D SW Pump D in maintenance 371 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWMMOSWPCS FAILURES OF SW PUMP C TO START SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1A SW Pump A in mainteneance SWTMPUMP1B SW Pump B in maintenance 372 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI BNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW0t D Is In Operation SWMMSWPCRT FAILURES OF SW PUMP C TO RUN SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance 373 TI00OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW0 B Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWTMPUMP1A SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance 374 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSWO1 B Is Nat In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGO.94E-07 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 375 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW0ID Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1C SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 370 TIOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI BNR FLAG - Service Water Pump PSW0IB Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C In maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ3.04E-07 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.04E-07 377 TIOO0OSW Total Losa of Service Water PCF PLANT CAPACITY FACTOR SWAASWP18NR FLAG - Service Water Pump PSWI1B Is Nat In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWrMPUMPIA SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVRERt7B17 BUS 17 UNDERVOLTAGE RELAY 27BI17 TRANSFERS TO DE-ENERGIZED 3.94E-07 378 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI BNR FLAG - Service Water Pump PSWOIB Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIB SW Pump 8 in maintenance SWTMPUMPlC SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 379 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance SWTMPUMPIC SI Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 380 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1IBNR FLAG - Service Water Pump PSW0IB Is Not In Operation SWAASWP1DR FLAG-Service Water Pump PSW01D Is In Operation I
1.00E+00 0.00E+00 0.98 0.76E-01 0.42 4.21E-01 0.42 4.21E-01 3.28E-03 3.28E-03 0.03 3.13E-02 0.05 4.55E-02 7.15E-03 7.15E-03 1
1.00En00 0.00E+00 0.88 8.71E-0I 0.42 4.21E-01 0.42 4.21E-01 2.05E-04 2.05E-04 0.05 4.55E-02 0.04 3.56E-02 7.15E-03 7.10E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.42 4.21E-01 2.05E-04 2.05E-04 0.03 3.13E-02 0.05 4.55E-02 7.15E-03 7.15E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.42 4.21E-01 0.03 3.13E-02 0.00 4.55E-02 0.04 3.56E-02 7.15E-03 7.15E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 3.28E-03 3.28E-03 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 1
1.00E+00 0.00E+00 0.88 8.78E-01 0.42 4.21E-01 0.58 5.790E-01 2.051-04 2.05E-04 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 1
1.00E+00 0.000+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 0.02 2.47E-02 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 1
1.000+00 0.00E+00 0.88 8.76E-01 0.42 4.21E001 0.58 5.790E-01 0.03 3.130-02 0.05 4.55E-02 0.04 3.56E-02 1
3.45E-03 1
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.42 4.21 E-01 0.58 5.79E001 0.03 3.13E-02 0.05 4.05E-02 0.04 3.56E-02 1
3.46E-03 I
3.45E-03 I
1.00E+00 0.00E+00 0.08 0.76E-01 0.42 4.21E001 0.58 5.79E-01 0.03 3.13Eo02 0.05 4.55E-02 0.04 3.56E-02 1
3.45E-03 I
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 1
3.45E-03 I
3.45E-03 I
1.00E+00 0.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.70E-01 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 1
3.45E-03 I
3.45E-03 1
1.00E+00 0.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.58 5.79E-01 0.03 3.13E-02 0.05 4.55E-02 0.04 3.56E-02 1
3.45E-03 1
3.45E-03 1
1.O0E+00 0.00E+00 0.88 8.76E-01 0.42 4.21E-01 0.08 5.70E-01
SWTMPUMP1A SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ3.84E-07 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 381 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWNTMPUMP1C SW Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVREiKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 382 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWPI DR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 UVRERI7BI7 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 383 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pomp PSW01B Is Nat In Operation SWAASWPIDR FLAG -Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A in maintenance SWIMPUMPIB SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGI.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 384 Tt0000SW Total Loss or Servioe Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW1 B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMPIA SW Pump A in maintenance SW'MPUMPIB SW Pump B in maintenance SWIMPUMPIC SW Pump C in maintenance UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 385 T 0OOOONW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW0t B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 386 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 387 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW0iB Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 388 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW0t B Is Nat In Operation SWAASWPIDR FLAG - Service Water Pump PSWO01D Is In Operation SWTMPUMP1A SWPump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWrMPUMP1C SW Pump C in maintenance UVREKI729O RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 389 1I0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSW01B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSVW0tD Is In Operation SWrMPUMP1A SW Pump A in maintenance SWTMPUMPIB SW Pump B in maintenance SWTMPUMP1C SIN Pump C in maintenance UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 390 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BNR FLAG - Service Water Pump PSW01 B Is Not In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SWPumpA in maintenance SWTMPUMPIB SW Pump B in maintenance SWrMIPUMPIC SW Pump C in maintenance UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 391 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSWM1B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is I Operation SWTMPUMP1A SW PumpA in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 392 TIO00OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1B SW Pump B in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 393 Tf0000SW Total Loss of Service Water 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 1
0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 1
1 1
0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 1
0.88 0.42 0.58 0.03 0.05 0.04 0.88 0.42 0.58 0.03 0.05 0.04 3.13E-02 4.552-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E.00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.78E-01 4.21 E-01 5.70E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.78E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00+E00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.002+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.002E00 8.78E-01 4.21E-01 5.78E-01 3.13E-02 4.55E-02 3.56E-02 3.452-03 3.45E-03 1.00E+00 0.00+E00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.562-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 SWTMPUMP1A SW Pump A in maintenance 0.03 SWTMPUMP1B SW Pump B in maintenance 0.05 SWTMPUMPIC SW Pump C in maintenance 0.04 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 1
UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27E/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
394 TI0000SW Total Loan of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1 BNR FLAG - Service Water Pump PSWO1B Is Nnt In Operation 0.42 SWAASWP1IDR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWTMPUMPIA SW Pump A in maintenance 0.03 SWTMPUMPIB SW Pump B In maintenance 0.05 SWTMPUMPIC SW Pump C in maintenance 0.04 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 I
UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/I 7 TRANSFERS TO DE-ENERGIZE3.94E-07 1
395 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 SWAASWP1DR FLAG - Service Water Pump PSWO1 D Is In Operalion 0.58 SWTMPUMPIA SW Pump A in maintenance 0.03 SWTMPUMP1B SW Pump B in maintenance 0.05 SWTMPUMPIC SW Pump C in maintenance 0.04 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
396 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Nat In Operation 0.42 SWAASWPIDR FLAG - Service Water Pump PFW01D Is In Operation 0.58 SWTMPUMPIA SW Pump A In maintenance 0.03 SWTMPUMP1B SW Pump B In maintenance 0.05 SWTMPUMP1C SIN Pump C in maintenance 0.04 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 1
397 TI0000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWTMPUMPIA SW Pump A In maintenance 0.03 SWTMPUMP1 B SW Pump B in maintenance 0.05 SWTMPUMPIC SW Pump C in maintenance 0.04 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D117 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
398 T10000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 SWAASWP1DR FLAG - Service Water Pump PSWO1D Is In Operation 0.58 SWTMPUMP1A SW Pump A in maintenance 0.03 SWTMPUMP1B SW Pump B in maintenance 0.05 SWTMPUMPIC SW Pump C in maintenance 0.04 UVRERi27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 1
UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/1117 TRANSFERS TO DE-ENERGIZE3.94E-07 1
399 TIOOOOSW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPISNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 SWMMOSWPCS FAILURES OF SW PUMP C TO START 3.28E-03 SWPPJIHDRB SERVICE WATER HEADER *B" PIPING RUPTURE 5.53E-07 I
SWTMPUMP1A SW Pump A in maintenance 0.03 SWTMPUMPIB SW Pump B in maintenance 0.05 400 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBNR FLAG - Service Water Pump PSWO1B Is Not In Operation 0.42 SWMMSWPCRT FAILURES OF SW PUMP C TO RUN 2.05E-04 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 I
SWTMPUMPIA SW Pump A In maintenance 0.03 SWTMPUMPIB SW Pump B in maintenance 0.05 401 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWP1BNR FLAG - Service Water Pump PSW01B Is Not In Operation 0.42 SWPPJIHDRB SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 1
SWTMPUMPlA SW Pump A i maintenance 0.03 SWTMPUMPIB SW Pump B In maintenance 0.05 SWTMPUMPIC SW Pump C in maintenance 0.04 402 TIOOOOSW Total Loan of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not tn Operatian 0.42 SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.28E-03 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWTMPUMPIC SW Pump C in maintenance 0.04 SW"MPUMPID SW Pump D in maintenance 7.15E-03 403 TIO000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation 0.42 SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN 2.05E-04 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWTMPUMPIC SW Pump C in maintenance 0.04 SWTMPUMPID SW Pump D in maintenance 7.151-03 404 TI0000SW Total Loss of Service Water I
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation 0.58 SWAASWP1DNR FLAG - Service Water Pump PSWOD Is Not In Operation 0.42 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWTMPUMPIA SW Pump A in maintenance 0.03 SWTMPUMPIC SW Pump C in maintenance 0.04 SWTMPUMPID SW Pump D in maintenance 7.15E-03 405 T10000SW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW01B In In Operation 0.58 SWAASWP1DR FLAG - Service Water Pump PSW01D is In Operation 0.58 SWMMSWPBRI FAILURES OF SW PUMP B TO RUN 0.02 SWMMSWPDRI FAILURES OF SW PUMP D TO RUN 0.02 SWTMPUMPIA SW Pump A In maintenance 0.03 SWTMPUMPIC SW Pump C in maintenance 0.04 406 TIOOOOSW Total Loss of Service Water 1
PCF PLANT CAPACITY FACTOR 0.88 SWAASWPIBR FLAG - Service Water Pump PSW1B Is In Operation 0.58 SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation 0.58 SWIMPUMPIA SW Pump A in maintenance 0.03 SWIMPUMPIC SW Pump C in maintenance 0.04 UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGB.94E-07 I
UVREKI729C RELAY 2-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 1
8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 878E-01 4.211E-01 5.78E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.000+00 0.00E+00 8.76E-01 4.210-01 5.79E-01 3.13E-02 4.55E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.000+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.55E-02 3.58E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 5.79E-01 3.13E-02 4.550-02 3.56E-02 3.45E-03 3.45E-03 1.00E+0+ 0.00E+00 8.76E-01 4.21E-01 3.28E-03 4.84E-03 3.13E-02 4.55E-02 1.000+00 0.00E+00 8.76E-01 4.21E-01 2.05E-04 4.84E-03 3.13E-02 4.55E-02 1.00E+00 0.00E+00 8.76E-01 4.21E-01 4.84E-03 3.13E-02 4.55E-02 3.58E-02 1.00nE00 0.00E+00 8.76E-01 5.70E-01 4.21E-01 3.28E-03 2.47E-02 3.56E-02 7.15E-03 1.00E+00 0.00E+00
&.76E-01 5.79E-01 4.21E-01 2.05E-04 2.47E-02 3.56E-02 7.15 E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 4.21E-01 2.47E-02 3.13E-02 3.56E-02 7.15E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 2.47E-02 2.47E-02 3.13E-02 3.56E-02 1.00+00 0.00E+00 8.76E-01 5.79E-01 5.70E-01 3.13E-02 3.58E-02 3.45E-03 3.45E-03
407 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A In maintenance SWTMPUMPIC SW Pump C In maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQ.94E-07 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 408 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1 DR FLAG - Service Water Pump PSWOt D Is In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMPIC SW Pump C In maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERQI.94E-07 UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/I7 TRANSFERS TO ENERGIZED 3.94E-07 409 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1C SW Pump C in maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG.94E-07 UVRERI7BI7 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 410 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW1B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWOD Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C In maintenance UVREKI729A RELAY 29-A IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER3.O4E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27DI/V17 TRANSFERS TO DE-ENERGIZE3.94E-07 411 710000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTIMPUMPIC SW Pump C in maintenance UVREKI7298 RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGL94E-07 UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 412 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWi1B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERG3.94E-07 UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 413 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW0IB Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWOID Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGN.94E-07 UVREKIB2I7 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 414 TIO300SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWID Is In Operation SWTMPUMP1A SW Pump A In maintenance SWTMPUMPIC SW Pump C In maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 278/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 415 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1 BR FLAG - Service Water Pump PSW01 B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1C SW Pump C in maintenance UVREKI729B RELAY 29-B IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENERGQ.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/BII 7 TRANSFERS TO DE-ENERGIZE3.94E-07 419 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWO1 B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1C SW Pump C in maintenance UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2117 TRANSFERS TO ENERGIZED 3.94E-07 417 1I0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 418 TIO0O0SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWID Is In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMPIC SW Pump C In maintenance UVREKI729C RELAY 29-C IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270117 TRANSFERS TO DE-ENERGIZED 3.94E-07 419 TI000OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 420 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWOIB Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWO10 Is In Operation SWTMPUMPIA SW Pump A In maintenance SWTMPUMPIC SW Pump C in maintenance UVREKI729D RELAY 29-f IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO D08ENERGIZED 3.94E-07 421 TI00OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR I
0.88 0.58 0.58 0.03 0.04 1
0.88 0.58 0.58 0.03 0.04 1
0.88 0.58 0.58 0.03 0.04 0.88 0.588 0.88 0.03 0.04 1
0.88 0.88 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 1
1 1
0.88 0.58 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 1
0.88 0.58 0.58 0.03 0.04 1
0.88 0.08 0.588 0.03 0.04 0.88 0.88 0.88 0.03 0.04 0.88 0.58 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 0.88 1.00E+00 0.00E+00 8.78E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.008+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.008+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.008+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 5.798E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 O.0OE+00 8.78E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E-00 0.001+00 8.78E-01 5.79E-01 5.798E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 O.OE+00 8.786-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.001+00 8.78E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.458-03 1.00E+00 0.001+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.001+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.78E-01
SWAASWP1BR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance UVREKI729D RELAY 29-D IN BUS 17 UNDERVOLTAGE CIRCUIT TRANSFERS TO ENER 3.94E-07 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D017 TRANSFERS TO DE-ENERGIZED 3.94E-07 422 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI BR FLAG - Service Water Pump PSFWIB Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW01 D Is In Operation SWTMPUMP1A SW Pump A In maintenance SWTMPUMPtC SW Pump C in maintenance UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 423 TIO00OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1lC SW Pump C in maintenance UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 424 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1IBR FLAG - Service Water Pump PSWOIB Is In Operation SWAASWPI DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance UVREKIB217 BUS 17 UNDERVOLTAGE RELAY 27BX2117 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 425 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMP1A SWPump A in maintenance SWTMPUMPiC SW Pump C In maintenance UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B117 TRANSFERS TO DE-ENERGIZED 3.94E-07 426 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSW01B Is In Operation SWAASWPIOR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPlA SW PumpA in maintenance SW'MPUMPIC SW Pump C in maintenance UVREKIX217 BUS 17 UNDERVOLTAGE RELAY 27X2/17 TRANSFERS TO ENERGIZED 3.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/0/17 TRANSFERS TO DE-ENERGIZE3.U4E-07 427 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI1R FLAG - Service Water Pump PSW01B Is In Operation SWAASWP1 DR FLAG - Service Water Pump PSWO1D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMPIC SW Pump C In maintenance UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27B/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 428 TI00OOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPI1R FLAG - Service Water Pump PSW1t B Is In Operation SWAASWP1 DR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMP1A SW Pump A in maintenance SWIMPUMP1C SW Pump C in maintenance UVRERI2717 BUS 17 UNDERVOLTAGE RELAY 27117 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B117 TRANSFERS TO DE-ENERGIZE3.94E-07 429 TIOGOOSW Total Loss of Service Water POF PLANT CAPACITY FACTOR SWAASWP1ER FLAG - Service Water Pump PSW01d Is In Operation SWAASWP1DR FLAG - Service Water Pump PSWOID Is In Operation SWTMPUMPIA SW PumpA in maintenance SWTMPUMPIC SW Pump C in maintenance UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 27D117 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7B17 BUS 17 UNDERVOLTAGE RELAY 27BI17 TRANSFERS TO DE-ENERGIZED 3.94E-07 430 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIBR FLAG - Service Water Pump PSWO1B Is In Operation SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance UVRERI27D7 BUS 17 UNDERVOLTAGE RELAY 270/17 TRANSFERS TO DE-ENERGIZED 3.94E-07 UVRERI7BD7 BUS 17 UNDERVOLTAGE RELAY 27D/B/17 TRANSFERS TO DE-ENERGIZE3.94E-07 431 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1BR FLAG - Service Water Pump PSWO18 Is In Operation SWMMSWPBRI FAILURES OF SW PUMP B TO RUN SWPPJIHDRE SERVICE WATER HEADER "B" PIPING RUPTURE 5.53E-07 SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance 432 TIOOOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPICNR FLAG - Service Water Pump PSW01C Is Not In Operation SWMMOSWPBS FAILURES OF SW PUMP B TO START 3.:
SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE 5.53E-07 SWTMPUMP1C SW Pump C In maintenance SWTMPUMP1D SW Pump D In maintenance
- 7.
433 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWP1CNR FLAG - Service Water Pump PSWI1C Is Not In Operation SWPPJIHDRA SERVICE WATER HEADER "A* PIPING RUPTURE S.53E-07 SWTMPUMP1B SW Pump B in maintenance SWTMPUMP1C SW Pump C in maintenance SWTMPUMPID SW Pump D in maintenance 7.1 434 T10000SW Total Loss of Service Water POF PLANT CAPACITY FACTOR SWAASWPICR FLAG - Service Water Pump PSW01C Is In Operation SWMMSWPCRI FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 6.53E-07 SWIMPUMPiB SW Pump 8 in maintenance SWTMPUMPID SW Pump D In maintenance 7.1 435 T10000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIDNR FLAG - Service Water Pump PSW01D Is Not In Operation SWMMOSWPAS FAILURES OF SW PUMP A TO START 3.2 SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE 5.53E-07 SWITMPUMPIC SW Pump C in maintenance SWT'MPUMPID SW Pump D in maintenance 7.1 436 T10000SW Total Loss of Service Water 0.58 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 0.88 0.58 0.68 0.03 0.04 0.88 0.58 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 1
0.88 0.58 0.58 0.03 0.04 0.88 0.58 1
0.588 0.58 0.58 0.03 0.04 1
0.88 0.58 0.58 0.03 0.04 0.88 0.58 0.58 0.03 0.04 1
0.88 0.58 0.02 1
0.04 I
0.88 0.42 286.03 0.04 1SE-O3 I
0.88 0.42 1
0.05 0.04 18E-03 t
0.88 0.58 0.02 1
0.05 5E-03 I
0.58 0.42 98-o03 0.04 5E-OS 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 O.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E.02 3.56E.02 3.45E-03 3.45E-03 1.00E-00 0.OOE÷00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.46E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 5.791-01 5.79E-01 3.13E-02 3.58E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.46E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 8.79E-01 5.79E-01 3.13E-02 3.56E-02 3.46E-03 3.45E-03 1.00E+00 O.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13&-02 3.56E-02 3.45E-03 3.4E-03 1.00E+00 O.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.00E+00 0.00E+00 8.76E-01 5.79E-01 5.79E-01 3.13E-02 3.56E-02 3.45E-03 3.45E-03 1.008+00 0.00E+00 8.76E-01 5.79E-01 2.47E-02 4.84E-03 3.13E-02 3.56E-02 1.00E+00 0.00E+00 8.76E-01 4.21E-01 3.28E-03 4.84E-03 3.561-02 7.15E-03 1.00E+00 0.00E+00 8.76E-01 4.21E-01 4.84E-03 4.55E-02 3.56E-02 7.15E-03 1.0012+00 0.008E00 8.76E-01 5.79E-01 2.47E-02 4.84E-03 4.55E-02 7.15E-03 1.006+00 0.006+00 8.76E-01 4.211E-01 3.28E-03 4.84E-03 3.56E-02 7.15E-03 1.00E+00 0.001+00
PCF PLANT CAPACITY FACTOR SWAASWPIDNR FLAG - Service Water Pump PSWO1D Is Not In Operatien SWPPJIHDRA SERVICE WATER HEADER "
PIPING RUPTURE SWTMPUMPIA SW Pump A in maintenance SWTMPUMP1C SW Pump C in maintenance SWTMPUMP1D SWN Pump D In maintenance 437 TISOOCSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWAASWPIDR FLAG - Service Water Pump PSW01D Is In Operation SWMMSWPDRI FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER A PIPING RUPTURE SWTMPUMPIA SW Pump A In maintenance SWTMPUMP1C SW Pump C In maintenance 438 TIO000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWCCPUMPSS Common Cause Fatlum Of Service Water Pumps To Start SWPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE SWPPJIHDRE SERVICE WATER HEADER B" PIPING RUPTURE 439 TI0003SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMOSWPAS FAILURES OF SW PUMP A TO START SWMMOSWPCS FAILURES OF SW PUMP C TO START SWPPJIHDRA SERVICE WATER HEADER A" PIPING RUPTURE SWPPJIHDRE SERVICE WATER HEADER B" PIPING RUPTURE 440 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMOSWPAS FAILURES OF SW PUMP A TO START SVPPJIHDRA SERVICE WATER HEADER "A" PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER "Br PIPING RUPTURE SWTMPUMPIC SW Pump C In maintenance 441 TI000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMOSWPBS FAILURES OF SW PUMP B TO START SWMMOSWPDS FAILURES OF SW PUMP D TO START SWPPJIHDRA SERVICE WATER HEADER "A7 PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER "B PIPING RUPTURE 442 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMOSWPBS FAILURES OF SW PUMP B TO START SWPPJIHDRA SERVICE WATER HEADER A" PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER 'B" PIPING RUPTURE SWTMPUMPID SW Pump D in maintenance 443 TI0000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMOSWPCS FAILURES OF SW PUMP C TO START SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER'"B PIPING RUPTURE SWTMPUMPIA SW Pump A in maintenance 444 T1000GW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMOSWPDS FAILURES OF SW PUMP D TO START SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADERSB" PIPING RUPTURE SWTMPUMPlB SW Pump B in maintenance 445 TI000SSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMSWPART FAILURES OF SERVICE WATER PUMP A TO RUN SWPPJIHDRA SERVICE WATER HEADER 'A" PIPING RUPTURE SWPPJIHDRS SERVICE WATER HEADER '"S PIPING RUPTURE SWTMPUMPiC SW Pump C in maintenance 446 TIOoOOSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMSWPCRT FAILURES OF SW PUMP C TO RUN SWPPJIHDRA SERVICE WATER HEADER "A' PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER "'" PIPING RUPTURE SWTMPUMPlA SW Pump A In maintenance "447 110000SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWMMSWPDRT FAILURES OF SW PUMP D TO RUN SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE SWPPJIHDRB SERVICE WATER HEADER"B" PIPING RUPTURE SWTMPUMPIB SW Pump B in maintenance 448 TIOO0OSW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE SWPPJIHDR8 SERVICE WATER HEADER 'B' PIPING RUPTURE SWTMPUMP1A SW Pump A In maintenance SWTMPUMP1C SW Pump C in maintenance 449 TIOO00SW Total Loss of Service Water PCF PLANT CAPACITY FACTOR SWPPJIHDRA SERVICE WATER HEADER 'A' PIPING RUPTURE SWPPJIHDRS SERVICE WATER HEADER "B" PIPING RUPTURE SWTMPUMPIS SW Pump B In maintenance SWTMPUMP1D SIN Pump D in maintenance Report Summary:
Filename: D:ACAFTA-VIOQUANTtEVELIILSW-IN-.CUT Print date: 068222001 1:15 PM Not sorted Printed In full 0.88 0.42 5.53E-07 1
0.03 0.04 7.15E-03 I
0.88 0.58 0.02 5.53E-07 1
0.03 0.04 1
0.88 1.14E-04 5.53E-07 1
5.53E-07 1
1 0.88 3.28E-03 3.28E-03 5.53E-07 1
5.53E-07 1
0.88 3.28E-03 5.53E-07 1
5.53E-07 1
0.04 1
0.88 3.28E-03 3.280E-03 5.53E-07 I
5.53E-07 1
1 0.88 3.28E-03 5.53E-07 1
5.53E-07 1
7.15&-03 I
0.88 3.28E-03 6.53E-07 I
5.53E-07 1
0.03 1
0.88 3.28E-03 5.53E-07 1
5.53E-07 1
0.05 1
0.88 2.05E-04 5.53E-07 I
5.53E-07 1
0.04 1
0.88 2.03E-04 5.53E-07 1
5.53E-07 1
0.03 1
0.88 2.05E-04 5.53E-07 1
5.53E-07 1
0.05 1
0.88 5.53E-07 1
5.53E-07 1
0.03 0.04 1
0.88 5.53E-07 I
5.53E-07 1
0.05 7.15E-03 8.76E-01 421E-01 4.84E-03 3.13E-02 3.56E-02 7.15E-03 1.00E000 0.0OE+00 8.76E-01 5.79E-01 2.47E-02 4.84E-03 3.13E-02 3.56E-02 1.00E+00 0.00E000 8.76E-01 1.140-04 4.84E-03 4.84E-03 1.00E+00 0.000+00 8.76E-01 3.28E-03 3.28E-03 4.84E-03 4.84E-03 1.00E+00 0.00E+00 8.76E-01 3.280-03 4.84E-03 4.84E-03 3.56E-02 1.00E+00 O.00E+00 8.78E-01 3.28E-03 3.28E-03 4.84E-03 4.84E-03 1.000+00 O.00E+00 8.76E-01 3.281-03 4.84E-03 4.84E-03 7.15E-03 1.00E+00 0.00E+00 8.76E-01 3.28E-03 4.84E-03 4.84E-03 3.13E-02 1.00E+00 0.03E+00 8.76E-01 3.28E-03 4.84E-03 4.84E-03 4.55E-02 1.00E000 0.000200 8.76E-01 2.05E-04 4.84E-03 4.84E-03 3.50E-02 1.00E+00 0.00E+00 8.76E-01 2.05E-04 4.84E-03 4.84E-03 3.13E-02 1.00E+00 0.00E+00
$.78E-01 2.05E-04 4.84E-03 4.84E-03 4.55E-02 1.00E+00 0.00E+00 8.76E-01 4.84E-03 4.84E-03 3.13E-02 3.56E-02 1.00E+00 0.00E+00 8.76E-01 4.84E-03 4.84E-03 4.55E-02 7.150-03
ATTACHMENT 5 June 29, 2001 Email From RGE To NRC,
Subject:
Mail Envelope Properties (3B3CAOA5.FDA* 22: 8154)
Subject:
Creation Date:
From:
Created By:
Loss of SW SDP 6/29/01 11:36AM
<Mark_Flaherty@rge.com>
Mark_Flaherty@rge.com Recipients nrc.gov kpI_po.KP__DO FJA (Frank Arner)
WLS (Wayne Schmidt)
JMT1 (James Trapp) rge.com Thomas _Harding CC Post Office kp lpo.KPDO Files MESSAGE RiskQuestions.wpd Header Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
Size 111 36497 1000 Date & Time 06/29/01 11:36AM None Standard No None No Standard Route nrc.gov rge.com
From:
<MarkFlaherty@rge.com>
To:
<JMTil@nrc.gov>, <wls@nrc.gov>, <FJA@nrc.gov>
Date:
6/29/01 11:37AM
Subject:
Loss of SW SDP Based on conversations with Jim Trapp on Wed, here is a revised letter:
(See attached file: RiskQuestions.wpd)
CC:
<ThomasHarding@rge.com>
SDP Questions Ginna SSDI In order to ensure that everyone is talking from the same page, here is a summary of the expected loss of service water (LOSW) scenario that will be used as a reference point in responding to the NRC questions.
A.
Given a LOSW, the plant would trip either automatically or manually within a few minutes due to loss of BOP related equipment, CCW to the RCPs' etc. The following equipment (as a minimum) will be assumed failed due to the loss of SW:
IA Compressors A, B, C. However, the service air compressor (normally cross tied to IA) and the diesel air compressor are available.
MDAFW Pumps A and B. However, the TDAFW pump will auto start on low SG level (shrink due to reactor trip) and the SAFW pumps will be available.
CCW high temperature alarms will result in tripping the CCW pumps. This will fail cooling to the RCPs (which will also be tripped) and the RHR heat exchangers (failing sump recirculation and RHR cooldown).
° MFW and Condensate pumps B.
Once the plant has tripped, the operators enter procedure E-0. It would be expected that SI conditions would not exist (nor a manual SI required) and operators would exit E-0 after step 4 and enter procedure ES-0.1.
C.
Upon exiting E-0, the STA would consult the Critical Safety Function Status Trees (CSFSTs) per EOP usage guides (procedure A-503. 1) and the note prior to the first step in ES-0.1. Included within the CSFSTs is verification that there is 200 gpm total AFW flow and 5% level in at least one SG. The STA performs this verification approximately once every 10-20 minutes (step 3.2.10.3 of procedure A-503.1). At this point, there is
- also a shift briefing to discuss-the plant status. It would be expected that the loss of SW would be discussed, but we will assume that this is not discussed for the purpose of this review.
D.
Procedure ES-0.1 provides instructions to the operators to stabilize the plant and bring it to hot shutdown conditions. There is a step to verify the number of operating SW pumps
(#5) and a continuous action step (#9) to verify SG level > 5%. The last step of the procedure requires the operators to consult plant staff to determine if cooldown is required and to go to procedure ES-0.2 for natural circulation cooldown (since there are no RCPs). It can be assumed that between the plant staff and licensed operators, that a decision would be made to limit the plant cooldown with no SW present since CCW and RHR are not available. However, it will be assumed that the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> run time with no SW lube oil cooling to the TDAFW pump will not be identified since this is only found in procedure ECA-0.0 (SBO).
E.
Procedure ES-0.2 instructs the operators to cooldown and depressurize the RCS using natural circulation. As mentioned above in D, it can be assumed that the plant cooldown would be limited with no SW available. However, it will now be assumed that the TDAFW pump fails after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of operation with no SW cooling for lube oil. Since AFW and maintaining SG level is a basis for providing natural circulation, it would be expected that operators would be monitoring it closely. The STA would also be monitoring these as part of the CSFSTs once every 10-20 minutes. Between these and the expected control board alarms, operators would transition to FR-H.1 upon loss of the TDAFW pump.
F.
Procedure FR-H. 1 instructs the operators to restore feedwater flow to the SGs first by preferred AFW, then by MFW, then by SAFW. Preferred AFW and MFW will be
assumed unavailable such that only SAFW can be used. EOP Attachment 5.1 instructs the operators to align SAFW taking suction from SW. Procedure ER-AFW. 1 provides instructions on how to use alternate suction sources (e.g., city and fire water); however, there is no direct links to ER-AFW.1 from FR-H.1 and Attachment 5.1 other than CST level < 5 feet. Regardless, the operators know that SW is unavailable and have been trained on the use for ER-AFW. 1 for similar type circumstances. That is, ER-AFW. 1 is considered to be an Abnormal Operating Procedure (AOP) that is referenced by the EOP series of procedures. Operators are trained and expected to utilize AOP type of procedures as needed in support of EOP implementation. Also, the minimum CST level specified in LCO 3.7.6 is based on providing sufficient inventory for the TDAFW pump for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> post trip in accordance with NUREG-0737, item II.E.1.1. As such, the operators would be expected to be procedurally directed into ER-AFW. 1 from low CST level at about the same time that the TDAFW pump would fail due to insufficient lube oil cooling.
See also H and I below.
G.
If AFW, MFW, and SAFW cannot be implemented by FR-H. 1, then the operators are instructed to use the condensate system or implement feed and bleed. The condensate system requires SW for motor cooling and would be unavailable. Feed and bleed occurs until necessary subcooling margin is obtained such that the SI pumps can be stopped and the PORVs closed. At this time, the plant would go to normal RHR shutdown cooling (requires SW), sump recirculation (requires SW), or stabilize on AFW that has been restored. Assuming a SI flowrate of 500 gpm (each pump is designed for 350 gpm and given the initial lower decay heat levels) and 300,000 gallons of RWST inventory, the need to be on RHR or AFW would not occur before 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />. It can be expected that either SW, the TDAFW pump, or SAFW would be recovered within this time frame.
However, the PSA model assumes that recirculation capability is required (i.e., there is no credit for this recovery).
H.
With respect to the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> run time of the TDAFW pump, attached is the current UFSAR description of this issue. As can be seen, there have been several tests of operating the TDAFW pump without any service water. The following summarizes these tests:
On March 6-8, 1981, RG&E conducted a 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> Endurance Test of all AFW pumps, including the TDAFW pump, in support of TMI Item II.E.1.1. The TDAFW pump was run on recirculation flow rate of 125 gpm for the duration of the test.
SW was isolated to the TDAFW pump (pump outboard bearing, quench tank, and lube oil cooling) at the onset of the test. One hour into the test, it was identified that the SW inlet valve to the pump outboard bearing was leaking by and the outlet valve was closed at that time. Steam then began emitting from the funnel drain at the pump bearing and at 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> 55 minutes, SW was restored to prevent the steaming from impacting the nearby control rod drive cabinets and causing a reactor trip. At 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> into the test, SW was again isolated to the TDAFW pump but restored to the outboard bearing 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 50 minutes later due to steaming issues again. The lube oil cooler remained isolated until 39 hours4.513889e-4 days <br />0.0108 hours <br />6.448413e-5 weeks <br />1.48395e-5 months <br /> into the test (i.e. for 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />). All pump parameters were within manufacturer recommendations.
On April 17, 1981 the TDAFW pump was run for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> without SW cooling under accident conditions (i.e., 200 gpm). All pump parameters were within manufacturer recommendations.
Based on the above, it is extremely conservative to assume that the TDAFW pump will fail after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of no SW cooling. It has been demonstrated that the TDAFW pump can run without lube oil cooling for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> under recirculation flow conditions
and 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> under design flow conditions. It has also been demonstrated that the TDAFW pump can run without cooling to the outboard bearing for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 55 minutes (with no credit for the first 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with a leaking SW valve) under recirculation flow conditions and 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> under design flow conditions. The only reason that these times are less than the lube oil cooler is due to test constraints and the desire to prevent a potential reactor trip, not from TDAFW pump operability concerns.
LCO 3.7.6 requires that one CST be filled up to 21.5 feet (22,500 gallons) to ensure 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of TDAFW water post-trip. However, Ginna Station has two CSTs, both of which are normally in service. Discussions with control room personnel indicate that they normally maintain the CSTs at approximately 21 feet (low level alarms begin to occur at 19 feet with overfill at around 23 feet). Since this is intended to be a PSA based, best estimate calculation, we can assume both tanks are at 21.5 feet (45,000 gallons). We can also assume that the TDAFW pump will run at 200 gpm for the first hour, 175 gpm for the second hour and 125 gpm for the subsequent hours based on decay heat loads.
Using this, we can calculate the time to reach 5 feet in both tanks (typical entry into ER AFW.1 per the EOPs):
If 21.5 feet equals 22,500 gallons, then 5 feet equals 5,232 gallons, or 10,464 gallons for two tanks.
Given the TDAFW pump flow rates, we calculate the inventory used as: 200 gpm (60 min) + 175 gpm (60 min) + 125 gpm (x min), or 22,500 gallons + 125x.
To calculate the time to reach 5 feet in both tanks:
- a.
45,000 gallons (2 full tanks) - 10,464 gallons (5 ft) = (22,500 gallons +
125x)
- b.
34,536 gallons = 22,500 gallons + 125x
- c.
x = 96 mins, or within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> of the event
- 1.
Does the Ginna PRA assume the need for the crosstie of the cooling water from the fire main for total loss of service water scenarios? If so, was the assumption of the frequency of success the same as assumed in AFHDALTTD? If so, this does not appear appropriate since the operator must recognize (proceduralized) the loss of fire water and take actions to align the city water to the fire headers (proceduralized) and also recognize (not proceduralized) the need to connect the temporary supply hose (proceduralized).
As indicated in PSA Final Report, Appendix F, Table F-4, event AFHFDALTTD is only credited for SBO scenarios (i.e., scenarios where procedure ECA-0.0 is entered). All other scenarios use a value of 1.0 for using fire water to support the TDAFW pump.
- 2.
How would you estimate the Diagnosis HEP for the LOSW event, (given no procedure guiding the operator recognition) verse time for:
- a.
The alignment of CitylFire water to the TDAFW pump of the need to complete Att-5.2?
- b.
The alignment of City Water to SAFW?
The diagnosis for alignment of fire water to the TDAFW pump (AFHFDALTTD) and city water to SAFW (AXHFDCITYW) was based on the following:
- a.
AFHFDALTTD - Cues to perform this action would only be available upon entering ECA-0.0, Step 8.d. All other scenarios do not credit this action (i.e.,
failure probability of 1.0).
- b.
AXHFDCITYW - Cues to perform this action would be from one of the following:
(1) low CST level - found on foldout page of all EOPs; (2) Step 13.a RNO of Procedure FR-C.1 for inadequate core cooling if SG level cannot be maintained >
5%; (3) Auxiliary Operator (AO) monitoring of the TDAFW per Step 3.6.3 of Procedure OPS-SHIFT-RESP which states "during abnormal or emergency conditions, the AOs shall be available to perform equipment monitoring and any local manipulations necessary, as directed by the SS, CRF, or Control Operators"; and (4) Step 7 of Procedure FR-H.1 for inadequate heat sink if SAFW cannot be aligned to SW. Note that for the last item, there is no direct procedural guidance. However, as described in item F of the event summary, operators are expected to utilize AOPs like ER-AFW. 1 in a situation like this. The calculation of this value was previously provided to the NRC and assumes that the operator had 20 minutes of diagnosis available. With 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of successful TDAFW operation, this diagnosis time would be much longer.
- 3.
Was the Total mean HEP for the City water to fire water ever calculated? Has it been calculated now? If so what is it? 'Please include the calculation).
No HEP for this event has ever been calculated, nor is there any intention of generating one at this time. Instructions to perform this step are not contained within-the EOP and AOP series of procedures (i.e., they are ir', other plant testing procedures). However, this activity is performed during testing and maintenance of the fire water systems and is called out in the TRM for when both fire pumps are inoperable (i.e., establish a backup fire water system). That is, operators are :aware of this capability.
- 4.
Reiative to crediting feed and bleed for a LOSW - What does the current PRA assume? We think that the SDP assumes no feed and bleed because-the recirc capability would not be available. Doez the PRA assume anything relative to the time dependance until the RWST reaches the point for swapover? Are there procedures in place for establishing a source of cooling water to the RHR Hxs, without SW?
The PSA utilizes a single transient event tree which contains, among other transients, the LOSW event (see PSA Final Report Figure 5-1). For the feed portion of feed and bleed, top event UH1 on the figure (High Pressure Injection) contains the logic for gate SR500, FAILURE TO DELIVER FLOW FROM I OF 3 SI PUMPS TO THE RCS DURING RECIRC. Since no recovery of SW is credited (as described in the event summary, item G), feed and bleed is not success for a LOSW event. However, since it would take over 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> to deplete the RWST, it could be postulated that the SW or AFW system would be recovered, or even the RWST refilled. There is no procedure which establishes an alternate source of cooling to the RHR HXs, primarily due to the number of AFW pumps.
- 5.
What is the current PRA core damage prob for LOSW? What would the LOSW core damage probability be given: (for each please include the sequences of interest and the assumed failure probabilities. If feed and bleed is credited please explain how.)
- a.
Inability to align Firewater to the TDAFW pump (given nominal failure probability for aligning city water to SAFW).
- b.
Inability to align Firewater to the TDAFW pump and inability to align city water to SAFW.
Three LOSW scenarios were solved as described beiow. In no instance is credit for feed and bleed taken.
LOSW as currently addressed within the PSA model - The attached cutset file (LOSW1.XLS) shows a of CDF 3.035E-06 with risk dominated by transients with no AFW available. Note that event AFHFDALTTD is only found in combination with a SBO event. Also, AXHFDCITYW is not found in the cutsets. This is due to the fact that there is already a human error event of failing to start SAFW per EOP steps (AXHFDSAFWX) within the models. For LOSW, this event also includes failure to align city water since no SW is available at the outset.
Consequently, event AXHFDSAFWX was increased by the necessary factor to result in a failure probability of 1.OE-02 similar to AFHFDALTTD.
LOSW with no credit for aligning Firewater to TDAFW - this is the same as the first sequence since event AFHFDALTTD is only credited for SBO cutsets.
LOSW with no credit for aligning Firewater to TDAFW nor city water to SAFW-If no credit is taken for TDAFW and the SAFW systems, then the CDF is equivalent to the LOSW frequency, or 2.OOE-04/yr (LOSW2.XLS). However, this scenario is not considered credible due to the reasons described below:
- a.
Operators treatment of ER-AFW.1 as a AOP which is entered as necessary in the EOPs.
- b.
Operators would initialize SAFW using FR-H. 1 once the TDAFW pump failed. Since this would not be expected to be implemented for at least 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> following the LOSW, operators would only need one SAFW pump due to low decay heat levels. The operator would start one pump which would quickly fail with no suction source if he attempted to use SW as the suction source as the procedure describes. Based on the extensive use of STAR practices, the operator would be expected to question why the pump failed before attempting to start a second SAFW pump.
- c.
If operators failed to align city water to SAFW in FR-H. 1, they would go to feed and bleed. Once this failed due to lack of RWST inventory and ability to go onto RHR, the core would heat up and the operators would enter FR-C.1. This procedure has specific guidance to enter ER-AFW.1 in step 13.a RNO for when SG level is < 5% and 200 gpm of AFW cannot be established..
- d.
AOs would be expected to be monitoring the status of the TDAFW pump as required by the procedure outlining shift responsibilities. This is especially true if the TDAFW pump is the only operating preferred AFW pump. If the AO identified pump problems (temperatures, steam, etc),
they would notify the control room who would be looking at alternatives.
- e.
As described in items H and I, the CST low level alarms are expected to occur at just over 3.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> into the event with an operating TDAFW pump. Based on the tests conducted in 1981, failure of the TDAFW pump is not expected to occur prior to this time. That is, the March 1981 test
was conducted with only a leaking SW valve supplying the outboard bearings for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and no SW cooling for the subsequent 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and 55 minutes.
Even assuming a generic operator failure rate of 0.1, and that items b and c are dependent (i.e., single event), this amounts to an operator error rate of 1 E-03 to start a SAFW pump under this scenario if the TDAFW pump were assumed to fail at an unlikely time of only 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
UFSAR 10.5.4.2 Alternating Current Independence of the Turbine-Driven Auxiliary Feedwater Pump (TDAFWMF As part of the review for NUREG 0737, Item II.E.1.1, Ginna Station was evaluated to determine if there was an essential dependence of the turbine-driven auxiliary feedwater pump (TDAFW) system on ac power. It was determined that the only ac dependence was the need for service water (SW) cooling of the lube-oil for the turbine-driven pump. The turbine-driven feedwater pump (TDAFW) has an ac lube-oil pump and a dc lube-oil pump. These pumps direct the oil through a heat exchanger, which depends on the ac-powered service water (SW) system pumps to cool the oil. The outboard (thrust) bearing of the pump is also provided directly with service water cooling through a water jacket within the bearing housing. The inboard pump radial bearing is cooled by an oil bath without an external source of cooling water. In the event:.
of a total loss of ac power, lube-oil cooling capability for the turbine-driven pump will be lost due to the loss of ac power to the service water (SW) pumps.
An NRC criterion (Recommendation GL-3 of NUREG-0737 Action Item I1.E.1.1) was that the as-built plant should be capable of providing the required preferred auxiliary feedwater flow for at least 2 hr from one preferred auxiliary feedwater pump train independent of any ac power source. As part of the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> Endurance Test conducted on March 6-8, 1981, RG&E performed a test with service water (SW) secured to the turbine's lube oil cooler and the pump outboard (thrust) bearing. The pump was run for a duration of 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> 55 minutes in one sequence without any service water cooling and for 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> in a later sequence without service water cooling to the turbine lube oil cooler. During the first sequence, excessive steaming from the floor drains with service water secured caused the reinitiation of service water (SW) to the pump thrust bearing. The Endurance Test was run in the recirculation mode with 125 gppm passing through the recirculation line back to the condensate storage tanks (CST). Throughcut the testing without service water supplied, the pump outboard (thrust) bearing, which is service, water cooled, and the inboard pump radial bearing (oil bath) were within manufacturer's limits of 165°F. The turbine governor bearing return oil temperature and turbine inboard bearing return oil temperature, as well as the turbine lube oil reservoir temperature, stabilized well within the manufacturer's limit of 180 0F.
In addition to the Endurance Test, another test was performed on April 17, 1981, for a period of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> without service water cooling to the outboard pump bearing and turbine lube oil cooler, this sequence with the pump delivering 200 gpm (100 gpm to each steam generator). This test was performed to simulate accident conditions. This test also confirmed that oil temperature, as well as pump and turbine bearing temperatures stabilized within acceptable limits.
In a letter dated June 8, 1981 (Reference 7) RG&E submitted the test results for these tests. In a letter dated June 16, 1982 (Reference 5) the NRC concluded that, based on the results of the recirculation flow test and the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> test on April 17, 1981, RG&E has shown that the turbine-driven auxiliary feedwater system (TDAFW) does not have an essential ac power dependence.