ML12132A324: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| issue date = 04/05/2012
| issue date = 04/05/2012
| title = 2012 Dresden Nuclear Power Station Initial License Examination ES-D-1 ILT-N-2
| title = 2012 Dresden Nuclear Power Station Initial License Examination ES-D-1 ILT-N-2
| author name = Reeser D W
| author name = Reeser D
| author affiliation = NRC/RGN-III/DRS/OB
| author affiliation = NRC/RGN-III/DRS/OB
| addressee name = Reeser D W, Nelson J
| addressee name = Reeser D, Nelson J
| addressee affiliation = Exelon Generation Co, LLC
| addressee affiliation = Exelon Generation Co, LLC
| docket = 05000237, 05000249
| docket = 05000237, 05000249
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:TQ-AA-151-F10 Revision 0 Page 1 of 1 SRRS: 3D.105 Scenario Outline Station: Dresden Generating Station Scenario No.:
{{#Wiki_filter:TQ-AA-151-F10 Revision 0 Page 1 of 1 Scenario Outline Station: Dresden Generating Station             Scenario No.: ILT-N-2         Class ID: 11-1 (2012-301)
ILT-N-2       Class ID:
Evaluators                                          Operators          / crew position
Evaluators Operators / crew position 11-1 (2012-301)         /   ATC     /   BOP Initial Conditions:
                                                                                      / ATC
/  CRS       Initial Power = 75%         Turnover:         Load drop to support FRV maintenance Swap Reactor Building Fans for maitenance Event Remove 2B FRV from service for maintenance No. Malf. No. Event Type* Event Description 1 NONE N B OP HVAC - Reactor Building Fans, Swap For Maintenance 2 NONE N ATC FW - FWRV, Remove From Service For Maintenance 3 ADS3CBN                  ADS3CSD C / T BOP MAIN STEAM  
                                                                                      / BOP
- ERV, Spurious Opening 4 RRMFNALO RRDFBTRP C ATC HVAC - Recirc MG Vent Fan, Trips Due To Overcurrent 5 HPINIT I / T BOP HPCI - System, Spurious Initiation 6 SER0512 C ATC DWEDS - Alarm Failure, Manually Pump Sumps 7 NP2 M TEAM Manual Scram  
                                                                                      / CRS Initial Conditions:        Initial Power = 75%
- Loss Of Instrument Air System.
Turnover:             Load drop to support FRV maintenance Swap Reactor Building Fans for maitenance Remove 2B FRV from service for maintenance Event          Malf.              Event                                    Event No.         No.                 Type*                                 Description 1         NONE               N       BOP    HVAC - Reactor Building Fans, Swap For Maintenance 2         NONE               N       ATC   FW - FWRV, Remove From Service For Maintenance ADS3CBN 3                           C/T     BOP   MAIN STEAM - ERV, Spurious Opening ADS3CSD RRMFNALO 4                             C       ATC   HVAC - Recirc MG Vent Fan, Trips Due To Overcurrent RRDFBTRP 5         HPINIT             I/T     BOP   HPCI - System, Spurious Initiation 6       SER0512             C       ATC   DWEDS - Alarm Failure, Manually Pump Sumps 7           NP2               M     TEAM   Manual Scram - Loss Of Instrument Air System.
8 HPRMBRKP M TEAM EMERGENCY DEPRESSURIZE  
EMERGENCY DEPRESSURIZE - On 2 Areas Above Max 8      HPRMBRKP              M      TEAM    Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.
- On 2 Areas Above Max Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.
* (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec SRRS: 3D.105}}
* (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec}}

Latest revision as of 04:38, 12 November 2019

2012 Dresden Nuclear Power Station Initial License Examination ES-D-1 ILT-N-2
ML12132A324
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 04/05/2012
From: David Reeser
Operations Branch III
To: David Reeser, Nelson J
Exelon Generation Co
Shared Package
ML11354A121 List:
References
Download: ML12132A324 (1)


Text

TQ-AA-151-F10 Revision 0 Page 1 of 1 Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-2 Class ID: 11-1 (2012-301)

Evaluators Operators / crew position

/ ATC

/ BOP

/ CRS Initial Conditions: Initial Power = 75%

Turnover: Load drop to support FRV maintenance Swap Reactor Building Fans for maitenance Remove 2B FRV from service for maintenance Event Malf. Event Event No. No. Type* Description 1 NONE N BOP HVAC - Reactor Building Fans, Swap For Maintenance 2 NONE N ATC FW - FWRV, Remove From Service For Maintenance ADS3CBN 3 C/T BOP MAIN STEAM - ERV, Spurious Opening ADS3CSD RRMFNALO 4 C ATC HVAC - Recirc MG Vent Fan, Trips Due To Overcurrent RRDFBTRP 5 HPINIT I/T BOP HPCI - System, Spurious Initiation 6 SER0512 C ATC DWEDS - Alarm Failure, Manually Pump Sumps 7 NP2 M TEAM Manual Scram - Loss Of Instrument Air System.

EMERGENCY DEPRESSURIZE - On 2 Areas Above Max 8 HPRMBRKP M TEAM Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.

  • (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec SRRS: 3D.105