TQ-AA-151-F10 Revision 0 Page 1 of 1 SRRS: 3D.105 Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-2 Class ID:
Evaluators Operators
/ crew position 11-1 (2012-301)
/ ATC
/ BOP Initial Conditions:
/ CRS Initial Power = 70%
Load dropped to support FRV Maintenance Turnover:
Remove 2B FWRV From Service For Maintenance Swap Reactor Building Fans For Maintenance Event Place HPCI on the Turning Gear No.
Malf.
No.
Event Type*
Event Description 1
NONE N
BOP HVAC - Reactor Building Fans, Swap For Maintenance 3
NONE N
ATC FW - FWRV, Remove From Service For Maintenance 4
RRMFAEXH C
ATC HVAC - Recirc MG Vent Fan, Degrades Causing Low Flow 4
HPTGFAIL C / T BOP HPCI - System, Inoperable Due to Failure of Turning Gear to Engage 5
SER0512 C
ATC DWEDS - Alarm Failure, Manually Pump Sumps 6
ADS3CBN ADS3CSD C / T BOP MAIN STEAM - ERV, Spurious Opening 7
NP2 M
TEAM Manual Scram - Loss Of Instrument Air System.
8 HPRMBRKP M
TEAM EMERGENCY DEPRESSURIZE - On 2 Areas Above Max Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.
- (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec