ML12284A373: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(2 intermediate revisions by the same user not shown)
Line 3: Line 3:
| issue date = 09/26/2012
| issue date = 09/26/2012
| title = 2012 Dresden Nuclear Power Station Initial License Examination ES-D-1 ILT-N-2 Rev 1
| title = 2012 Dresden Nuclear Power Station Initial License Examination ES-D-1 ILT-N-2 Rev 1
| author name = Reeser D W
| author name = Reeser D
| author affiliation = NRC/RGN-III/DRS/OB
| author affiliation = NRC/RGN-III/DRS/OB
| addressee name = Nelson J
| addressee name = Nelson J
Line 14: Line 14:
| page count = 1
| page count = 1
}}
}}
=Text=
{{#Wiki_filter:TQ-AA-151-F10 Revision 0 Page 1 of 1 Scenario Outline Station: Dresden Generating Station            Scenario No.: ILT-N-2          Class ID: 11-1 (2012-301)
Evaluators                                          Operators          / crew position
                                                                                      / ATC
                                                                                      / BOP
                                                                                      / CRS Initial Conditions: Initial Power = 70%
Load dropped to support FRV Maintenance Turnover:            Remove 2B FWRV From Service For Maintenance Swap Reactor Building Fans For Maintenance Place HPCI on the Turning Gear Event          Malf.              Event                                    Event No.          No.                Type*                                Description 1          NONE              N      BOP    HVAC - Reactor Building Fans, Swap For Maintenance 3          NONE              N      ATC    FW - FWRV, Remove From Service For Maintenance 4      RRMFAEXH              C      ATC    HVAC - Recirc MG Vent Fan, Degrades Causing Low Flow HPCI - System, Inoperable Due to Failure of Turning Gear 4        HPTGFAIL            C/T      BOP to Engage 5        SER0512              C      ATC    DWEDS - Alarm Failure, Manually Pump Sumps ADS3CBN 6                            C/T      BOP    MAIN STEAM - ERV, Spurious Opening ADS3CSD 7          NP2              M      TEAM    Manual Scram - Loss Of Instrument Air System.
EMERGENCY DEPRESSURIZE - On 2 Areas Above Max 8      HPRMBRKP              M      TEAM    Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.
* (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec SRRS: 3D.105}}

Latest revision as of 22:27, 11 November 2019

2012 Dresden Nuclear Power Station Initial License Examination ES-D-1 ILT-N-2 Rev 1
ML12284A373
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 09/26/2012
From: David Reeser
Operations Branch III
To: Nelson J
Exelon Generation Co
Shared Package
ML11354A121 List:
References
Download: ML12284A373 (1)


Text

TQ-AA-151-F10 Revision 0 Page 1 of 1 Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-2 Class ID: 11-1 (2012-301)

Evaluators Operators / crew position

/ ATC

/ BOP

/ CRS Initial Conditions: Initial Power = 70%

Load dropped to support FRV Maintenance Turnover: Remove 2B FWRV From Service For Maintenance Swap Reactor Building Fans For Maintenance Place HPCI on the Turning Gear Event Malf. Event Event No. No. Type* Description 1 NONE N BOP HVAC - Reactor Building Fans, Swap For Maintenance 3 NONE N ATC FW - FWRV, Remove From Service For Maintenance 4 RRMFAEXH C ATC HVAC - Recirc MG Vent Fan, Degrades Causing Low Flow HPCI - System, Inoperable Due to Failure of Turning Gear 4 HPTGFAIL C/T BOP to Engage 5 SER0512 C ATC DWEDS - Alarm Failure, Manually Pump Sumps ADS3CBN 6 C/T BOP MAIN STEAM - ERV, Spurious Opening ADS3CSD 7 NP2 M TEAM Manual Scram - Loss Of Instrument Air System.

EMERGENCY DEPRESSURIZE - On 2 Areas Above Max 8 HPRMBRKP M TEAM Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.

  • (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec SRRS: 3D.105