{{#Wiki_filter:TQ-AA-151-F10 Revision 0 Page 1 of 1 SRRS: 3D.105 Scenario Outline Station: Dresden Generating Station Scenario No.:
{{#Wiki_filter:TQ-AA-151-F10 Revision 0 Page 1 of 1 Scenario Outline Station: Dresden Generating Station             Scenario No.: ILT-N-2         Class ID: 11-1 (2012-301)
ILT-N-2       Class ID:
Evaluators                                          Operators          / crew position
Evaluators Operators / crew position 11-1 (2012-301)         /   ATC     /   BOP Initial Conditions:
                                                                                      / ATC
/  CRS  Initial Power = 70%
                                                                                      / BOP
Load dropped to support FRV Maintenance Turnover: Remove 2B FWRV From Service For Maintenance Swap Reactor Building Fans For Maintenance Event Place HPCI on the Turning Gear No. Malf. No. Event Type* Event Description 1 NONE N BOP HVAC - Reactor Building Fans, Swap For Maintenance 3 NONE N ATC FW - FWRV, Remove From Service For Maintenance 4 RRMFAEXH C ATC HVAC - Recirc MG Vent Fan, Degrades Causing Low Flow 4 HPTGFAIL C / T BOP HPCI - System, Inoperable Due to Failure of Turning Gear to Engage 5 SER0512 C ATC DWEDS - Alarm Failure, Manually Pump Sumps 6 ADS3CBN                  ADS3CSD C / T BOP MAIN STEAM  
                                                                                      / CRS Initial Conditions: Initial Power = 70%
- ERV, Spurious Opening 7 NP2 M TEAM Manual Scram  
Load dropped to support FRV Maintenance Turnover:             Remove 2B FWRV From Service For Maintenance Swap Reactor Building Fans For Maintenance Place HPCI on the Turning Gear Event          Malf.              Event                                    Event No.         No.                 Type*                                 Description 1         NONE               N       BOP   HVAC - Reactor Building Fans, Swap For Maintenance 3         NONE               N       ATC   FW - FWRV, Remove From Service For Maintenance 4       RRMFAEXH             C       ATC   HVAC - Recirc MG Vent Fan, Degrades Causing Low Flow HPCI - System, Inoperable Due to Failure of Turning Gear 4        HPTGFAIL            C/T      BOP to Engage 5       SER0512             C       ATC   DWEDS - Alarm Failure, Manually Pump Sumps ADS3CBN 6                           C/T     BOP   MAIN STEAM - ERV, Spurious Opening ADS3CSD 7           NP2               M     TEAM   Manual Scram - Loss Of Instrument Air System.
- Loss Of Instrument Air System.
EMERGENCY DEPRESSURIZE - On 2 Areas Above Max 8      HPRMBRKP              M      TEAM    Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.
8 HPRMBRKP M TEAM EMERGENCY DEPRESSURIZE  
* (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec SRRS: 3D.105}}
- On 2 Areas Above Max Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.
* (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec}}

Latest revision as of 22:27, 11 November 2019

2012 Dresden Nuclear Power Station Initial License Examination ES-D-1 ILT-N-2 Rev 1
ML12284A373
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 09/26/2012
From: David Reeser
Operations Branch III
To: Nelson J
Exelon Generation Co
Shared Package
ML11354A121 List:
References
Download: ML12284A373 (1)


Text

TQ-AA-151-F10 Revision 0 Page 1 of 1 Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-2 Class ID: 11-1 (2012-301)

Evaluators Operators / crew position

/ ATC

/ BOP

/ CRS Initial Conditions: Initial Power = 70%

Load dropped to support FRV Maintenance Turnover: Remove 2B FWRV From Service For Maintenance Swap Reactor Building Fans For Maintenance Place HPCI on the Turning Gear Event Malf. Event Event No. No. Type* Description 1 NONE N BOP HVAC - Reactor Building Fans, Swap For Maintenance 3 NONE N ATC FW - FWRV, Remove From Service For Maintenance 4 RRMFAEXH C ATC HVAC - Recirc MG Vent Fan, Degrades Causing Low Flow HPCI - System, Inoperable Due to Failure of Turning Gear 4 HPTGFAIL C/T BOP to Engage 5 SER0512 C ATC DWEDS - Alarm Failure, Manually Pump Sumps ADS3CBN 6 C/T BOP MAIN STEAM - ERV, Spurious Opening ADS3CSD 7 NP2 M TEAM Manual Scram - Loss Of Instrument Air System.

EMERGENCY DEPRESSURIZE - On 2 Areas Above Max 8 HPRMBRKP M TEAM Safe Radiation Levels Due To HPCI Steam Line Leak into the HPCI Room.

  • (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor, (T)ech Spec SRRS: 3D.105