Line 20: |
Line 20: |
| 10 CFRWRITTEN NOTIFICATION FOR HEX HEAD CAP SCREWS NOVA MACHINE PRODUCTS PART NUMBERS: BPRT.008227.30, BPRT.008468.30, AND BPRT .008342.30. | | 10 CFRWRITTEN NOTIFICATION FOR HEX HEAD CAP SCREWS NOVA MACHINE PRODUCTS PART NUMBERS: BPRT.008227.30, BPRT.008468.30, AND BPRT .008342.30. |
| FOLLOW-UP TO INITIAL NOTIFICATION DATED JULY 13, 2017. | | FOLLOW-UP TO INITIAL NOTIFICATION DATED JULY 13, 2017. |
| Pursuant to 1OCFR21.21 (d)( 4) Nova Machine Products is providing the required written notification and final report of the identification of a defect in Nova Machine Fastener P/N BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30. | | Pursuant to 10CFR21.21 (d)( 4) Nova Machine Products is providing the required written notification and final report of the identification of a defect in Nova Machine Fastener P/N BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30. |
| On the basis of an evaluation conducted by both Nova Machine and Exelon it has been determined that the subject condition, if left uncorrected, has a potential to create substantial safety hazard. | | On the basis of an evaluation conducted by both Nova Machine and Exelon it has been determined that the subject condition, if left uncorrected, has a potential to create substantial safety hazard. |
| The enclosure to this letter provides the information required by 1OCFR21.21 (d) (4). | | The enclosure to this letter provides the information required by 10CFR21.21 (d) (4). |
| This letter also serves as the final report regarding the subject parts. | | This letter also serves as the final report regarding the subject parts. |
| If there are any questions pertaining to this communication, please contact Tad Gray, General Manager, at 216-898-8374 or Frank Furfari, Sr. Quality Assurance Manager at 216-898-8394. | | If there are any questions pertaining to this communication, please contact Tad Gray, General Manager, at 216-898-8374 or Frank Furfari, Sr. Quality Assurance Manager at 216-898-8394. |
| ~~~ce~ly, | | ~~~ce~ly, |
| ~~ | | ~~ |
| ;ad Graf' U v General Manager - Nova & AP Services Attachment 1: 1OCFR21 Written Notification | | ;ad Graf' U v General Manager - Nova & AP Services Attachment 1: 10CFR21 Written Notification |
|
| |
|
| CURT/SS-WRIGHT Page 1of 3 Written Report Attachment 1 (i) Name and address of the individual or individuals informing the Commission. | | CURT/SS-WRIGHT Page 1of 3 Written Report Attachment 1 (i) Name and address of the individual or individuals informing the Commission. |
|
---|
Category:Deficiency Correspondence (per 10CFR50.55e and Part 21)
MONTHYEARML19325C0942019-11-0707 November 2019 Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch ZJS1518 Final Report Per 10 CFR Part 21 ML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML19263A6662019-09-0909 September 2019 Lake Engineering Co. - Third Interim Notification Per 10 CFR Part 21: Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 ML19210D4342019-07-11011 July 2019 Curtiss-Wright SAS - 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 ML19190A0432019-06-28028 June 2019 Discusses Proprietary Information for Curtiss-Wright SAS - 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 - Cw SAS Initial Report No. 10CFR21-48 ML19029A1552018-12-27027 December 2018 10 CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0123, Rev. 1 ML17223A2002017-08-0909 August 2017 10 CFR Written Notification for Hex Head Cap Screws Nova Machine Products Part Numbers: BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30 ML17104A2882017-04-13013 April 2017 Emerson Process Management, LLC - Fisher Information Notice, (FIN) 2017-02 ML17114A0712017-04-13013 April 2017 10 CFR Part 21 Notification of Deviation - Gkt Relay ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML14105A0182014-04-11011 April 2014 Part 21 - Model 1154HP Transmitters with Integral 1159 Remote Diaphragm Seals May Exhibit Degraded Functional Reliability ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13002A0302012-12-21021 December 2012 Part 21 Notification - Defect Discoveredd in COM-5 and SSC-T Protective Relays Distributed by Abb, Inc ML12094A3712012-04-0202 April 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12097A3162012-03-0202 March 2012 Part 21 Report - Rosemont Pressure Tranmitters Out of Tolerance Condition ML12066A1182012-03-0202 March 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML0328704222003-10-0909 October 2003 Potential Safety Condition for Eaton Cutler-Hammer Type W Vintage Unit Plug-In Stabs 2019-09-09
[Table view] Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML20108F5302020-03-20020 March 2020 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0129, Rev. 0, Test Stand Deficiency - EMD Fuel Injectors P/N H40084720 ML20024E2552020-01-0909 January 2020 Engine Systems, Inc., Submittal of Selenium Surge Suppressor, Emo P/N 8403049 ML19347A4262019-12-10010 December 2019 General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) ML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML19199A0342019-07-0505 July 2019 Lake Engineering Co., Third Interim Notification Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 ML19190A0442019-06-0707 June 2019 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 - Cw SAS Initial Report No. 10CFR21-48 ML19168A0122019-05-31031 May 2019 Paragon Energy Solution LLC-10 CFR Part 21 Report of Defect GS2 Terry Turbine Introl Positioners ML19168A0102019-05-31031 May 2019 Curtis-Wright Nuclear Division- Notification Report for Potential Part 21 Update ML19077A0962019-03-0505 March 2019 Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 ML17243A1362017-08-28028 August 2017 Fisher Information Notice, (FIN) 2017-04 - Erroneous Rotary Seating Torque Calculation in Flowscanner Software ML17223A2002017-08-0909 August 2017 10 CFR Written Notification for Hex Head Cap Screws Nova Machine Products Part Numbers: BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30 ML17179A3782017-06-0707 June 2017 TE Connectivity - Part 21 Transfer of Information TE-023 ML17114A0712017-04-13013 April 2017 10 CFR Part 21 Notification of Deviation - Gkt Relay ML17114A0702017-04-13013 April 2017 Part 21 Notification - Identified Fisher 546S Electro-Pneumatic Transducers Standard Mounting Brackets Failed Seismic Testing Standards ML17104A2882017-04-13013 April 2017 Emerson Process Management, LLC - Fisher Information Notice, (FIN) 2017-02 ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML16321A4512016-10-21021 October 2016 Part 21 Reporting of Defects and Noncompliance ML16251A0982016-09-0202 September 2016 Part 21 - Potential Failure of Battery System Connections ML16243A4722016-08-25025 August 2016 Part 21 Reporting of Defects and Noncompliance ML16139A8342016-05-10010 May 2016 Electroswitch - Transmittal of 10CFR Part 21 Reporting of Defects and Noncompliance Regarding Vendor Inspection of Electroswitch Corporation Docket No. 99900833 ML16039A2692016-02-0303 February 2016 Nutherm International, Inc. - Potential Issue Regarding Incorrect Industrial Irradiation Dose, Per Cooper, Oconee, Fitzpatrick, Point Beach, Brunswick, and Susquehanna ML15103A2442015-04-0606 April 2015 Part 21 Report - Deviation of Hk Circuit Breaker Close Latch Spring ML15022A6502015-01-20020 January 2015 Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification ML14274A0522014-09-22022 September 2014 Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities ML14105A0182014-04-11011 April 2014 Part 21 - Model 1154HP Transmitters with Integral 1159 Remote Diaphragm Seals May Exhibit Degraded Functional Reliability ML14094A4452014-04-0101 April 2014 Notification of Part 21 Report on Defective Raw Material Used to Manufacture Valve Stems ML14069A4682014-03-0202 March 2014 Part 21 Report - Defective Raw Material Used to Manufacture Valve Stems ML14042A2022014-02-0505 February 2014 Part 21 Report Regarding Unqualified Material Used in Electrical Penetration Assemblies ML13277A0102013-09-23023 September 2013 Interim Report Update for Component ASME Material Supplied by Mirion Technologies (Conax Nuclear), Inc. (Mtcn), as Part of Containment Electric Penetration Assemblies (EPA) ML13246A0842013-08-23023 August 2013 Notification of Potential Defect & Interim Report Regarding a Potential Defect of Materials Supplied to Operating Us Nuclear Power Plants by Mirion Technologies (Conax Nuclear) Inc. (Mtcn) with Containment Electric Penetration Assemblies ML13238A2532013-08-21021 August 2013 Notification of Potential Part 21 Report - Foxboro Power Supply Potential Failures Due to Defective the Wraps and Holders ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13142A3292013-05-0606 May 2013 Notification of Potential Part 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0109, Rev. 0 ML13127A0142013-05-0303 May 2013 Part 21 Report - Fuel Injectors Failed Pressure Test ML13093A1532013-04-0202 April 2013 Part 21 Report - Foxboro Power Supply Potential Failures Due to Defective Tie Wraps and Holders ML13073A1072013-03-12012 March 2013 Notification of Potential Part 21 Report - Defective Raw Material Used to Manufacture Valve Stems ML13064A0122013-02-25025 February 2013 Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve ML13002A4702012-12-28028 December 2012 10 C.F.R. Part 21 Notification to Customers - COM-5 and SSC-T Protective Relays - Telephone Relay Armature Pivot Pin, Resubmitted to Include Attachment 1, Which Was Inadvertently Omitted in the Original Fax ML13002A0302012-12-21021 December 2012 Part 21 Notification - Defect Discoveredd in COM-5 and SSC-T Protective Relays Distributed by Abb, Inc ML12352A1232012-12-13013 December 2012 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML12348A1362012-12-13013 December 2012 Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers ML12094A3712012-04-0202 April 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12066A1182012-03-0202 March 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12097A3162012-03-0202 March 2012 Part 21 Report - Rosemont Pressure Tranmitters Out of Tolerance Condition ML12058A1412012-02-23023 February 2012 Part 21 Report - Rosemount Nuclear Instruments, Inc., Pressure Transmitter with Nonzero Based Calibrations ML0914904882009-05-28028 May 2009 Notification of Potential Part 21 Report Re Air Circuit Breaker Deficiency ML0904007482009-02-0505 February 2009 Update to Part 21 Report Notification, Texas Instruments Operational Amplifier, P/N: OPA 2111 ML0823901062008-08-25025 August 2008 Notification of Potential Part 21 on Failure of F and G Switches ML0809906342008-04-0404 April 2008 Part 21 Notification Regarding Failure to Comply with the Requirements for Dedication of Commercial Grade Items 2020-03-20
[Table view] |
Text
Nuclear Division CURT/SS- 18001 Sheldon Road WRIGHT Middleburg Heights, OH 44130 T: 216.267.3200 www.curtisswright.com/NuclearDivision Nova Machine Products US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Date: August 9, 2017
SUBJECT:
10 CFRWRITTEN NOTIFICATION FOR HEX HEAD CAP SCREWS NOVA MACHINE PRODUCTS PART NUMBERS: BPRT.008227.30, BPRT.008468.30, AND BPRT .008342.30.
FOLLOW-UP TO INITIAL NOTIFICATION DATED JULY 13, 2017.
Pursuant to 10CFR21.21 (d)( 4) Nova Machine Products is providing the required written notification and final report of the identification of a defect in Nova Machine Fastener P/N BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30.
On the basis of an evaluation conducted by both Nova Machine and Exelon it has been determined that the subject condition, if left uncorrected, has a potential to create substantial safety hazard.
The enclosure to this letter provides the information required by 10CFR21.21 (d) (4).
This letter also serves as the final report regarding the subject parts.
If there are any questions pertaining to this communication, please contact Tad Gray, General Manager, at 216-898-8374 or Frank Furfari, Sr. Quality Assurance Manager at 216-898-8394.
~~~ce~ly,
~~
- ad Graf' U v General Manager - Nova & AP Services Attachment 1
- 10CFR21 Written Notification
CURT/SS-WRIGHT Page 1of 3 Written Report Attachment 1 (i) Name and address of the individual or individuals informing the Commission.
Tad Gray General Manager Curtiss-Wright - Nuclear Division Nova Machine Products 18001 Sheldon Road Middleburg Heights Ohio 44130 (ii) Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a defect:
Hex Head Cap Screw Nova Machine Products part numbers: BPRT.008227.30, BPRT.008468.30, and BPRT.008342.30.
All 3 part numbers manufactured from the same forged blank size-same manufacturing run -
same Heat Number.
(iii) Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect:
Curtiss-Wright - Nuclear Division Nova Machine Products 18001 Sheldon Road Middleburg Heights Ohio 44130 (iv) Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply:
Pre-existing cracks found in screws supplied to Exelon may cause premature failure.
Fasteners were all produced from one heat of material, which was used to forge one blank size, which was then used to produce three hex head cap screw sizes. These fasteners are isolated to one heat of material and one manufacturing run.
These fasteners were only supplied to Exelon TMI and Exelon Peach Bottom. TM! had not installed any of the subject bolts and have already returned the subject screws back to Nova Machine.
Nova has been in constant communication with Exelon-Peach Bottom. Some bolts had been installed in emergency diesel generators and Peach Bottom has evaluated the safety significance.
CURTISS--
WRIGHT Written Report Page 2of3 Attachment 1 All but six screws have already been replaced. These six are on schedule to be replaced by Exelon in the very near future.
(v) The date on which the information of such defect or failure to comply was obtained:
July 12, 2017.
(vi) In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part:
I Qu\jntity <
Quantity returned or Nova Part# ... Customer
. Shipped .. *
(EA) being return*e(J I
23 {6 given to Peach BPRT.008227.30 Exelon-TM I 23 Bottom BPRT.008227.30 Exelon-Peach 14 14 BPRT.008227.30 Exelon-Peach 6 6 BPRT.008468.30 Exelon-Peach 8 8 BPRT.008342.30 Exelon-Peach 11 11 (vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the ~ction:
- Exelon-TM! and Exelon-Peach Bottom were the only two locations supplied with this heat of material. Nova Machine initiated a return of all subject fasteners from Exelon which were produced from this specific heat. TM.I did not install any of the suspect screws and all the screws from TMI have been returned to Nova Machine with the exception of six pieces which TMI had sent to Peach Bottom.
CURTISS--
WRIGHT Written Report Attachment 1 Page 3 of3 The fasteners in question were all machined from the same blank forging, which was produced from the same heat of material. The forgings were produced by Nova Machine's approved sub-supplier.
The starting material was UNS S41600 stainless steel. This type of stainless is more susceptible to cracking when cooled rapidly from the forging temperature.
The root cause of the defect (small cracks) in the fastener was attributed to the rapid quenching (water quench) of the blanks immediately following the forging step. The water quenching after forging was limited to this heat of material and one manufacturing run only.
Review of Quality records for this condition indicate that prior and post manufacturing runs were n~t water quenched. Water quenching was limited to one manufacturing run only.
Finished parts are supplied to ASTM F 593 type 416 Condition H.
Corrective actions are documented in Nova CAR #300 and include but are.not limited to elimination of water quenching after forging and implementation of Non-destructive examination on the finished product.
(viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.
Both Nova Machine and Exelon Peach Bottom have been in constant communication on the issue. Exelon Peach Bottom is the only site with remaining subject screws. They are in the process of returning any remaining screws back to Nova Machine Products.
(ix) In the case of an early site permit, the entities to whom an early site permit was transferred.
Not Applicable.