| number = ML16256A235
| number = ML16256A235
| issue date = 08/25/2016
| issue date = 08/25/2016
| title = Waterford Steam Electric Station, Unit 3, Revision 309 to Final Safety Analysis Report, Chapter 5, Reactor Coolant System and Connected Systems, Section 5.0 - Reactor Coolant System and Connected Systems
| title = Revision 309 to Final Safety Analysis Report, Chapter 5, Reactor Coolant System and Connected Systems, Section 5.0 - Reactor Coolant System and Connected Systems
| author name =  
| author name =  
| author affiliation = Entergy Operations, Inc
| author affiliation = Entergy Operations, Inc
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:WSES-FSAR-UNIT-3  5.1-1 Revision 307 (07/13) 5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS 5.1 SUMMARY DESCRIPTION The reactor is a pressurized water reactor (PWR) with two coolant loops. The Reactor Coolant System (RCS) circulates coolant (borated water) in a closed cycle, removing heat from the reactor core and internals and transferring it to a secondary (steam generating) system. In a pressurized water reactor, the steam generators provide the interface between the Reactor Coolant (primary) System and the Main Steam (secondary) System. The steam generators are vertical U-tube heat exchangers in which heat is transferred from the reactor coolant to the Main Steam System. Reactor coolant is prevented from mixing with the secondary steam by the steam generator tubes and the steam generator tube sheet. This makes the RCS a closed system which forms a barrier to the release of radioactive materials from the core of the reactor to the containment.
{{#Wiki_filter:WSES-FSAR-UNIT-3  5.1-1 Revision 307 (07/13) 5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS 5.1  
The arrangement of the RCS is shown in Figures 5.1-1 and 2. The major components of the system are the reactor vessel; two parallel heat transfer loops, each containing one steam generator and two reactor coolant pumps; a pressurizer connected to one of the reactor vessel outlet pipes; and associated piping. All components are located inside the containment. Effluent discharges from the pressurizer safety valves are condensed and cooled in the quench tank. (EC-8458, R307) The major impacts to the RCS due to steam generator replacement were evaluated. An increase in RCS volume of approximately 4%, an increase in heat transfer capability, and a slight change in normal RCS flow rate are expected. The potential impact to specific RCS functional requirements and design bases were addressed in detail, and based on those evaluations the evaluated RCS functional and performance requirements are met following steam generator replacement. (EC-8458, R307) Table 5.1-1 shows the principal pressures, temperatures and flowrates of the RCS under normal steady-state, full-power operating conditions. Instrumentation provided for operation and control of the system is described in Chapter 7.  
 
==SUMMARY==
DESCRIPTION  
 
The reactor is a pressurized water reactor (PWR) with two coolant loops. The Reactor Coolant System (RCS) circulates coolant (borated water) in a closed cycle, removing heat from the reactor core and internals and transferring it to a secondary (steam generating) system.
In a pressurized water reactor, the steam generators provide the interface between the Reac tor Coolant (primary) System and t he Main Steam (secondary) System.
The steam generators are vertical U-tube heat exchangers in which heat is transferred from the reactor coolant to the Main Steam System. Reactor coolant is prevent ed from mixing with the secondary steam by the steam generator tubes and the steam generator tube sheet. This makes the RCS a closed system which forms a barrier to the release of radioactive materials from the core of the reactor to the containment.  
 
The arrangement of the RCS is shown in Figures 5.1-1 and 2. The major components of the system are the reactor vessel; two parallel heat transfer loops, each containing one steam generator and two reactor coolant pumps; a pressurizer connected to one of the reactor ve ssel outlet pipes; and associated piping. All components are located inside the containment. Effluent discharges from the pressurizer safety valves are condensed and cooled in the quench tank.
(EC-8458, R307)
The major impacts to the RCS due to steam generator repl acement were evaluated. An increase in RCS volume of approximately 4%, an increase in heat transfer capabilit y, and a slight change in normal RCS flow rate are expected. The potential impact to specific RCS func tional requirements and design bases were addressed in detail, and based on those evaluations the evaluated RCS functional and performance requirements are met following steam generator replacement. (EC-8458, R307)
Table 5.1-1 shows the principal pressures, temperat ures and flowrates of the RCS under normal steady-state, full-power operating conditions. Instrumentation provided for operation and control of t he system is described in Chapter 7.
 
System pressure is controlled by t he pressurizer, where steam and water are maintained in thermal equilibrium.
Steam is formed by energizing immersion heaters in the pre ssurizer, or is condensed by the pressurizer spray to limit pressure variations caused by contra ction or expansion of the reactor coolant.  


System pressure is controlled by the pressurizer, where steam and water are maintained in thermal equilibrium. Steam is formed by energizing immersion heaters in the pressurizer, or is condensed by the pressurizer spray to limit pressure variations caused by contraction or expansion of the reactor coolant.
The average temperature of the reactor coolant varies with power level and the fluid expands or contracts, changing the pressurizer water level.  
The average temperature of the reactor coolant varies with power level and the fluid expands or contracts, changing the pressurizer water level.  


The charging pumps and letdown control valves in the Chemical and Volume Control System (CVCS) are used to maintain the programmed pressurizer water level. A continuous but variable letdown purification flow is maintained to keep the RCS chemistry within prescribed limits. Two charging nozzles and a letdown nozzle are provided on the reactor coolant piping for this operation. The charging flow is also used to alter the boron concentration or correct the chemistry of the reactor coolant.
The charging pumps and letdown control valves in the C hemical and Volume Control Sy stem (CVCS) are used to maintain the programmed pressurizer water level. A continuous but variable letdown purification flow is maintained to keep the RCS chemistry within prescribed limits. Two charging nozzles and a letdown nozzle are provided on the reactor coolant piping for this operation. The charging flow is also used to alter the boron  
Other reactor coolant loop penetrations are the pressurizer surge line in one reactor vessel outlet pipe; the four safety injection inlet nozzles, one in each reactor vessel inlet pipe; one outlet nozzle to the Shutdown Cooling System in each reactor vessel outlet pipe; two pressurizer spray nozzles; vent and drain connections; and sample connections and instrument connections.
 
WSES-FSAR-UNIT-35.1-2Overpressure protection for the reactor coolant pressure boundary is provided by two spring-loaded ASME Codesafety valves connected to the top of the pressurizer. These valves discharge to the quench tank, where the steam is released under water to be condensed and cooled. If the steam discharge exceeds the capacity of the quench tank, it is relieved to the containment atmosphere through a rupture disc.Overpressure protection for the secondary side of the steam generators is provided by 12 spring-loaded ASMECode safety valves located in the Main Steam System upstream of the main steam isolation valves.Components and piping in the RCS are insulated with a material compatible with the temperatures involved toreduce heat losses and protect personnel from high temperatures. All insulation material used has a low soluble chloride and other halide content to minimize the possibility of stress corrosion of stainless steel.Principal parameters of the RCS are listed in Table 5.1-2. Table 5.1-3 lists RCS volumes.Shielding requirements of the surrounding concrete structures are described in Section 12.3. Reactor CoolantSystem shielding permits limited personnel access to the containment building during power operation. The reactor vessel sits in a thick walled concrete well. This and other shielding reduces the dose rate within thecontainment and outside the shield wall during full power operation to acceptable levels.5.1.1SCHEMATIC FLOW DIAGRAM The principal pressures, temperatures, and flow rates at major components are listed in Table 5.1-1. Theseparameters are referenced to Figure 5.1-3, the piping and instrument diagram, by numbered locations.Instrumentation provided for operation and control of the RCS is described in Chapter 7 and is indicated on Figure 5.1-3.5.1.2PIPING AND INSTRUMENT DIAGRAM Figure 5.1-3 is the piping and instrument diagram of the RCS. The entire system is located within the containment.Fluid systems which are connected to the Reactor Coolant System and which include the limits of the reactor coolant pressure boundary as defined in 10CFR50.2 (v), are identified and the appropriate piping and instrument diagrams in other sections are referenced. Figure 5.1-4 is the piping and instrument diagram for the reactor coolant pump seals.5.1.3ELEVATION DRAWING Major components of the RCS are surrounded by concrete structures, which provide support plus shielding andmissile protection. Elevation drawings, illustrating principal dimensions of the RCS in relationship to the surrounding concrete structures, are provided on Figures 1.2-17 through 1.2-22.
concentration or correct the chem istry of the reactor coolant.  
WSES-FSAR-UNIT-3   TABLE 5.1-1 Revision 307 (07/13) PROCESS DATA POINT TABULATION   (DRN 03-2059, R14) Parameter Pressurizer S.G. 1-A Midpoint Pump  1-B Outlet Reactor Vessel Midpoint Pump 1-A Outlet S.G. 2-A Midpoint Pump 2-A Outlet Pump 2-B Outlet  Data Point Figure 5.1-3 1 2 3 4 5 6 7 8 Pressure, psig 2,250 2,232.0 2,306.4 2,282.1 2,306.4 2,232.0 2,306.4 2,306.4 (EC-8458, R307)        Temperature, F  652.7 572.5 543 572.5 543 572.5 543 543 Mass Flowrate lbm/hr  (x 106)  - 81.8 40.9 163.5 40.9 81.8 40.9 40.9 Volumetric Flow-rate, gpm  (x 104)  - 21.5 10.8 43.1 10.8 21.5 10.8 10.8 (DRN 03-2059, R14; EC-8458, R307)
 
WSES-FSAR-UNIT-3     TABLE 5.1-2 Revision 307 (07/13)   (DRN 03-2059, R14) PARAMETERS OF REACTOR COOLANT SYSTEM _______________________________________________________________________________________  Parameter Value
Other reactor coolant loop penetrations are the pressurize r surge line in one reactor vessel outlet pipe; the four safety injection inlet nozzles, one in each reactor vesse l inlet pipe; one outlet nozzle to the Shutdown Cooling System in each reactor vessel outlet pipe; two pressuri zer spray nozzles; vent and drain connections; and sample connections and instrument connections.
_______________________________________________________________________________________
WSES-FSAR-UNIT-3 5.1-2Overpressure protection for the reactor coolant pressure boundary is provided by two spring-loaded ASME Codesafety valves connected to the top of the pressurizer. These valves discharge to the quench tank, where the steam is released under water to be condensed and cooled. If the steam discharge exceeds the capacity of the quench tank, it is relieved to the containment atmosphere through a rupture disc.Overpressure protection for the secondary side of the steam generators is provided by 12 spring-loaded ASMECode safety valves located in the Main Steam System upstream of the main steam isolation valves.Components and piping in the RCS are insulated with a material compatible with the temperatures involved toreduce heat losses and protect personnel from high temperatures. All insulation material used has a low soluble chloride and other halide content to minimize the possibility of stress corrosion of stainless steel.Principal parameters of the RCS are listed in Table 5.1-2. Table 5.1-3 lists RCS volumes.Shielding requirements of the surrounding concrete structures are described in Section 12.3. Reactor CoolantSystem shielding permits limited personnel access to the containment building during power operation. The reactor vessel sits in a thick walled concrete well. This and other shielding reduces the dose rate within thecontainment and outside the shield wall during full power operation to acceptable levels.5.1.1SCHEMATIC FLOW DIAGRAM The principal pressures, temperatures, and flow rates at major components are listed in Table 5.1-1. Theseparameters are referenced to Figure 5.1-3, the piping and instrument diagram, by numbered locations.Instrumentation provided for operation and control of the RCS is described in Chapter 7 and is indicated on Figure 5.1-3.5.1.2PIPING AND INSTRUMENT DIAGRAM Figure 5.1-3 is the piping and instrument diagram of the RCS. The entire system is located within the containment.Fluid systems which are connected to the Reactor Coolant System and which include the limits of the reactor coolant pressure boundary as defined in 10CFR50.2 (v), are identified and the appropriate piping and instrument diagrams in other sections are referenced. Figure 5.1-4 is the piping and instrument diagram for the reactor coolant pump seals.5.1.3ELEVATION DRAWING Major components of the RCS are surrounded by concrete structures, which provide support plus shielding andmissile protection. Elevation drawings, illustrating principal dimensions of the RCS in relationship to the surrounding concrete structures, are provided on Figures 1.2-17 through 1.2-22.
WSES-FSAR-UNIT-3 TABLE 5.1-1 Revision 307 (07/13)
PROCESS DATA POINT TABULATION (DRN 03-2059, R14)
Parameter  
 
Pressurizer S.G. 1-A Midpoint Pump  1-B Outlet Reactor Vessel Midpoint Pump 1-A Outlet S.G. 2-A Midpoint Pump 2-A Outlet Pump 2-B Outlet  Data Point  
 
Figure 5.1-3  
 
1 2 3 4 5 6 7 8 Pressure, psig  
 
2,250 2,232.0 2,306.4 2,282.1 2,306.4 2,232.0 2,306.4 2,306.4 (EC-8458, R307)        Temperature, F  652.7 572.5 543 572.5 543 572.5 543 543 Mass Flowrate  
 
lbm/hr  (x 10
: 6)  - 81.8 40.9 163.5 40.9 81.8 40.9 40.9 Volumetric Flow-  
 
rate, gpm  (x 10
: 4)  - 21.5 10.8 43.1 10.8 21.5 10.8 10.8 (DRN 03-2059, R14; EC-8458, R307)
WSES-FSAR-UNIT-3 TABLE 5.1-2 Revision 307 (07/13)
(DRN 03-2059, R14)
PARAMETERS OF REACTOR COOLANT SYSTEM
_______________________________________________________________________________________  Parameter Value  
 
_______________________________________________________________________________________  


Rated Thermal Power, Mwt (core only) 3,716  
Rated Thermal Power, Mwt (core only) 3,716  


Thermal Power Btu/hr (including heat addition from RCPs) 1.274 x 1010 Design Pressure, psia 2,500  
Thermal Power Btu/hr (including heat addition from RCPs) 1.274 x 10 10 Design Pressure, psia 2,500  
 
Design Temperature (except pressurizer and surge line),  F 650 Pressurizer and Surge Line Design Temperature,  F 700  (EC-8458, R307)
Coolant Flow Rate, Operating, lbm/hr 163.5 x 10 6 (EC-8458, R307)
Cold Leg Temperature, Operating,  F 543  (EC-8458, R307)
Average Temperature, Operating,  F 572.5  Hot Leg Temperature, Operating,  F 602 (DRN 03-2059, R14; EC-8458, R307)
Normal Operating Pressure, psia 2,250 (EC-8458, R307)
System Water Volume, ft.
3 (without pressurizer) 10,485 (EC-8458, R307)
Pressurizer Water Volume, ft.
3 (full power) 800


Design Temperature (except pressurizer and surge line), F 650 Pressurizer and Surge Line Design Temperature, F 700  (EC-8458, R307) Coolant Flow Rate, Operating, lbm/hr 163.5 x 106 (EC-8458, R307)  Cold Leg Temperature, Operating, F 543  (EC-8458, R307) Average Temperature, Operating, F 572.5  Hot Leg Temperature, Operating, F 602 (DRN 03-2059, R14; EC-8458, R307)  Normal Operating Pressure, psia 2,250  (EC-8458, R307) System Water Volume, ft.3 (without pressurizer) 10,485 (EC-8458, R307)  Pressurizer Water Volume, ft.3 (full power) 800 Pressurizer Steam Volume, ft.3 (full power) 700
Pressurizer Steam Volume, ft.
3 (full power) 700
_______________________________________________________________________________________
_______________________________________________________________________________________
WSES-FSAR-UNIT-3  TABLE 5.1-3 Revision 307 (07/13) NOMINAL REACTOR COOLANT SYSTEM VOLUMES _______________________________________________________________________________________  Component Volume (ft.3) _______________________________________________________________________________________ (EC-8458, R307) Reactor Vessel (including nozzles) 4,811  Steam Generators (including nozzles) 2,051 each (EC-8458, R307) Reactor Coolant Pumps 112 each (EC-8458, R307) Pressurizer 1,519 Piping Hot Leg 145 each (EC-8458, R307) Cold Leg 198 each (EC-8458, R307)  Surge Line 39 (EC-8458, R307) _______________________________________________________________________________________}}
WSES-FSAR-UNIT-3  TABLE 5.1-3 Revision 307 (07/13)
NOMINAL REACTOR COOLANT SYSTEM VOLUMES
_______________________________________________________________________________________  Component Volume (ft.
: 3) _______________________________________________________________________________________ (EC-8458, R307)
Reactor Vessel (including nozzles) 4,811  Steam Generators (including nozzles) 2,051 each (EC-8458, R307)
Reactor Coolant Pumps 112 each (EC-8458, R307)
Pressurizer 1,519 Piping Hot Leg 145 each (EC-8458, R307)
Cold Leg 198 each (EC-8458, R307)  Surge Line 39 (EC-8458, R307)
_______________________________________________________________________________________}}

Latest revision as of 19:55, 6 May 2019

Revision 309 to Final Safety Analysis Report, Chapter 5, Reactor Coolant System and Connected Systems, Section 5.0 - Reactor Coolant System and Connected Systems
ML16256A235
Person / Time
Site: Waterford Entergy icon.png
Issue date: 08/25/2016
From:
Entergy Operations
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16256A115 List: ... further results
References
W3F1-2016-0053
Download: ML16256A235 (5)


Text

WSES-FSAR-UNIT-3 5.1-1 Revision 307 (07/13) 5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS 5.1

SUMMARY

DESCRIPTION

The reactor is a pressurized water reactor (PWR) with two coolant loops. The Reactor Coolant System (RCS) circulates coolant (borated water) in a closed cycle, removing heat from the reactor core and internals and transferring it to a secondary (steam generating) system.

In a pressurized water reactor, the steam generators provide the interface between the Reac tor Coolant (primary) System and t he Main Steam (secondary) System.

The steam generators are vertical U-tube heat exchangers in which heat is transferred from the reactor coolant to the Main Steam System. Reactor coolant is prevent ed from mixing with the secondary steam by the steam generator tubes and the steam generator tube sheet. This makes the RCS a closed system which forms a barrier to the release of radioactive materials from the core of the reactor to the containment.

The arrangement of the RCS is shown in Figures 5.1-1 and 2. The major components of the system are the reactor vessel; two parallel heat transfer loops, each containing one steam generator and two reactor coolant pumps; a pressurizer connected to one of the reactor ve ssel outlet pipes; and associated piping. All components are located inside the containment. Effluent discharges from the pressurizer safety valves are condensed and cooled in the quench tank.

(EC-8458, R307)

The major impacts to the RCS due to steam generator repl acement were evaluated. An increase in RCS volume of approximately 4%, an increase in heat transfer capabilit y, and a slight change in normal RCS flow rate are expected. The potential impact to specific RCS func tional requirements and design bases were addressed in detail, and based on those evaluations the evaluated RCS functional and performance requirements are met following steam generator replacement. (EC-8458, R307)

Table 5.1-1 shows the principal pressures, temperat ures and flowrates of the RCS under normal steady-state, full-power operating conditions. Instrumentation provided for operation and control of t he system is described in Chapter 7.

System pressure is controlled by t he pressurizer, where steam and water are maintained in thermal equilibrium.

Steam is formed by energizing immersion heaters in the pre ssurizer, or is condensed by the pressurizer spray to limit pressure variations caused by contra ction or expansion of the reactor coolant.

The average temperature of the reactor coolant varies with power level and the fluid expands or contracts, changing the pressurizer water level.

The charging pumps and letdown control valves in the C hemical and Volume Control Sy stem (CVCS) are used to maintain the programmed pressurizer water level. A continuous but variable letdown purification flow is maintained to keep the RCS chemistry within prescribed limits. Two charging nozzles and a letdown nozzle are provided on the reactor coolant piping for this operation. The charging flow is also used to alter the boron

concentration or correct the chem istry of the reactor coolant.

Other reactor coolant loop penetrations are the pressurize r surge line in one reactor vessel outlet pipe; the four safety injection inlet nozzles, one in each reactor vesse l inlet pipe; one outlet nozzle to the Shutdown Cooling System in each reactor vessel outlet pipe; two pressuri zer spray nozzles; vent and drain connections; and sample connections and instrument connections.

WSES-FSAR-UNIT-3 5.1-2Overpressure protection for the reactor coolant pressure boundary is provided by two spring-loaded ASME Codesafety valves connected to the top of the pressurizer. These valves discharge to the quench tank, where the steam is released under water to be condensed and cooled. If the steam discharge exceeds the capacity of the quench tank, it is relieved to the containment atmosphere through a rupture disc.Overpressure protection for the secondary side of the steam generators is provided by 12 spring-loaded ASMECode safety valves located in the Main Steam System upstream of the main steam isolation valves.Components and piping in the RCS are insulated with a material compatible with the temperatures involved toreduce heat losses and protect personnel from high temperatures. All insulation material used has a low soluble chloride and other halide content to minimize the possibility of stress corrosion of stainless steel.Principal parameters of the RCS are listed in Table 5.1-2. Table 5.1-3 lists RCS volumes.Shielding requirements of the surrounding concrete structures are described in Section 12.3. Reactor CoolantSystem shielding permits limited personnel access to the containment building during power operation. The reactor vessel sits in a thick walled concrete well. This and other shielding reduces the dose rate within thecontainment and outside the shield wall during full power operation to acceptable levels.5.1.1SCHEMATIC FLOW DIAGRAM The principal pressures, temperatures, and flow rates at major components are listed in Table 5.1-1. Theseparameters are referenced to Figure 5.1-3, the piping and instrument diagram, by numbered locations.Instrumentation provided for operation and control of the RCS is described in Chapter 7 and is indicated on Figure 5.1-3.5.1.2PIPING AND INSTRUMENT DIAGRAM Figure 5.1-3 is the piping and instrument diagram of the RCS. The entire system is located within the containment.Fluid systems which are connected to the Reactor Coolant System and which include the limits of the reactor coolant pressure boundary as defined in 10CFR50.2 (v), are identified and the appropriate piping and instrument diagrams in other sections are referenced. Figure 5.1-4 is the piping and instrument diagram for the reactor coolant pump seals.5.1.3ELEVATION DRAWING Major components of the RCS are surrounded by concrete structures, which provide support plus shielding andmissile protection. Elevation drawings, illustrating principal dimensions of the RCS in relationship to the surrounding concrete structures, are provided on Figures 1.2-17 through 1.2-22.

WSES-FSAR-UNIT-3 TABLE 5.1-1 Revision 307 (07/13)

PROCESS DATA POINT TABULATION (DRN 03-2059, R14)

Parameter

Pressurizer S.G. 1-A Midpoint Pump 1-B Outlet Reactor Vessel Midpoint Pump 1-A Outlet S.G. 2-A Midpoint Pump 2-A Outlet Pump 2-B Outlet Data Point

Figure 5.1-3

1 2 3 4 5 6 7 8 Pressure, psig

2,250 2,232.0 2,306.4 2,282.1 2,306.4 2,232.0 2,306.4 2,306.4 (EC-8458, R307) Temperature, F 652.7 572.5 543 572.5 543 572.5 543 543 Mass Flowrate

lbm/hr (x 10

6) - 81.8 40.9 163.5 40.9 81.8 40.9 40.9 Volumetric Flow-

rate, gpm (x 10

4) - 21.5 10.8 43.1 10.8 21.5 10.8 10.8 (DRN 03-2059, R14; EC-8458, R307)

WSES-FSAR-UNIT-3 TABLE 5.1-2 Revision 307 (07/13)

(DRN 03-2059, R14)

PARAMETERS OF REACTOR COOLANT SYSTEM

_______________________________________________________________________________________ Parameter Value

_______________________________________________________________________________________

Rated Thermal Power, Mwt (core only) 3,716

Thermal Power Btu/hr (including heat addition from RCPs) 1.274 x 10 10 Design Pressure, psia 2,500

Design Temperature (except pressurizer and surge line), F 650 Pressurizer and Surge Line Design Temperature, F 700 (EC-8458, R307)

Coolant Flow Rate, Operating, lbm/hr 163.5 x 10 6 (EC-8458, R307)

Cold Leg Temperature, Operating, F 543 (EC-8458, R307)

Average Temperature, Operating, F 572.5 Hot Leg Temperature, Operating, F 602 (DRN 03-2059, R14; EC-8458, R307)

Normal Operating Pressure, psia 2,250 (EC-8458, R307)

System Water Volume, ft.

3 (without pressurizer) 10,485 (EC-8458, R307)

Pressurizer Water Volume, ft.

3 (full power) 800

Pressurizer Steam Volume, ft.

3 (full power) 700

_______________________________________________________________________________________

WSES-FSAR-UNIT-3 TABLE 5.1-3 Revision 307 (07/13)

NOMINAL REACTOR COOLANT SYSTEM VOLUMES

_______________________________________________________________________________________ Component Volume (ft.

3) _______________________________________________________________________________________ (EC-8458, R307)

Reactor Vessel (including nozzles) 4,811 Steam Generators (including nozzles) 2,051 each (EC-8458, R307)

Reactor Coolant Pumps 112 each (EC-8458, R307)

Pressurizer 1,519 Piping Hot Leg 145 each (EC-8458, R307)

Cold Leg 198 each (EC-8458, R307) Surge Line 39 (EC-8458, R307)

_______________________________________________________________________________________