WSES-FSAR-UNIT-3 3.9C-1 APPENDIX 3.9C DESCRIPTION OF SEISMIC ANALYSIS AND
SUMMARY
OF RESULTS FOR NON-NSSS SUPPLIED ACTIVE VALVES Seismic qualification of Code Class 1, 2 and 3 active valves consists of determination of rigidity, verification of structural adequacy and conclusion of operability of valve-actuator assemblies under seismic conditions. Check valve are considered adequate for seismic loading on the basis of the following considerations:
a)
Lack of external actuator and topworks b)
Absence of actuator loads c)
Simplicity of the hinge mechanism d)
Low seismic accelerations e)
Small hinge pin deflections f)
Clearance tolerance for rotating parts less critical than for parts requiring linear motion (i.e. valve stems)
Seismic loads are considered in Class 1 Design Reports for Code Class 1 check valves with nominal inlet sizes greater than 4 inches. These valves and the Class 1 Design Reports are listed in Table 3.9C-2.
Although not required, TRW Mission performed analysis and submitted seismic reports for Code Class 2 and 3 wafer type check valves. These are listed in Table 3.9C-3.
Valve and actuator assemblies are determined to be acceptable for service under earthquake load by meeting the following criteria:
a)
Determination of lowest natural frequency to confirm rigidity of the assembly. Rigidity is defined as the lowest natural frequency of the topworks to be 33 Hertz. This ensures that the valve-actuator assemblies are more rigid than the piping system which is designed not to exceed a period of 0.20. Rigid valve-actuator assemblies are modeled as simple eccentric loads on the piping in the system seismic analysis. This ensures that the seismic load on the valves is not amplified by the flexibility of the topworks structure to exceed 1.0g in the horizontal and 0.67g in the vertical directions, and permits the use of a static analysis of the topworks to confirm structural adequacy. Valve-actuator assemblies that are non-rigid are dynamically tested to prove structural adequacy and are dynamically modeled in the system seismic analysis.
b)
Confirmation of structural adequacy of the valve topworks and connecting bolting under seismic loads and other applicable loads such as actuator thrust or discharge reaction forces.
WSES-FSAR-UNIT-3 3.9C-2 c)
Proof of operability by either implicit conclusion based on past experience and demonstration of very low stress levels in critical parts, deflection analysis, or testing.
Valves with actuators and topworks are determined to be acceptable for service under earthquake loadings without loss of function by one of the four methods described below. The qualification consists of either mathematical modeling and analysis, actual testing, or a combination of both. These methods are outlined below and referenced in Table 3.9C-1.
Method 1:
a.
Analytical determination of natural frequency.
b.
Analytical verification of structural integrity.
c.
Analytical conclusion of operability.
Method 2:
a.
Analytical determination of natural frequency.
b.
Analytical verification of structural integrity.
c.
Static deflection test for confirmation of operability.
Method 3:
(Performed on complete valve-actuator assembly) a.
Testing for determination of natural frequency.
b.
Analytical verification of structural integrity.
c.
Dynamic testing to confirm operability.
Method 4:
(Performed on topworks and actuator only) a.
Testing for determination of natural frequency.
b.
Analytical verification of structural integrity.
c.
Dynamic operability testing of topworkers/actuator only.
This method is used on large bore valves with large actuators that are either too complicated to model accurately, where testing of the complete valve-actuator assembly is impractical, or when the structure has been analytically determined to be non-rigid. It is assumed that the valve body is massive enough to not be significantly distorted by the eccentric loading of the topworks during seismic loads and that motion of internal moving parts will not be impeded.
In all of the above qualification methods, structural adequacy of the non-pressure retaining parts is verified by calculating the stresses in the yoke structures and attachment bolts and confirming that they are below the yield stress for the material.
The stresses for pressure retaining materials are calculated to be below the S values of Tables 1.7-1 and 1.7-2 (as applicable) of the applicable ASME Code and Addenda.
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 1 of 12)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 1SI-V1501B Lunkenheimer 1
Anamet Lab No. 78.042, 3/27/78 V1593A 1SI-V1502B Lunkenheimer 1
Anamet Lab No. 227.14 Rev A, V1504A 3/13/78 1SI-V1505TK1A Lunkenheimer 1
Anamet Lab No. 227l.15 Rev A, V1506TK1B 3/13/78 V1507TK2A V1508TK2B 2SI-L101A Fisher Controls 1
Seismic Analysis of 4", 12",
L102B 20" and 24" Butterfly Valve L103A Assemblies Rev 2, 1/30/80 2SI-FM318AA Fisher Controls 1
Seismic Analysis of 4", 10",
FM349B and 12" Butterfly Valve Assemblies Rev 2, 1/30/80 3CC-TM291B Fisher Controls 1
Seismic Analysis of 4", 10",
and 12" Butterfly Valve Assemblies Rev 2, 4/23/80 3CC-TM290A Fisher Controls 1
Seismic Analysis of 12" and 16" Butterfly Valve Assemblies, 11/17/78 3CC-F109A/B Fisher Controls 3
Dynamic Test Program on Bettis F110A/B T312-SR3-M3 and 722C-SR80-M3 F111A/B Actuator, 6/5/79 F112A/B F114A/B F115A/B F116A/B 3FW-V607A Pacific 1
Seismic Analysis Report V610B FA-5267, 8/26/77 2MS-V697 Velan 1
Seismic Analysis of 1"-1500 lb V698 Forged Carbon Steel Bonnetless Globe Valve SR-6208, 11/7/82
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 2 of 12)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 3CC-TM148A Fisher Controls 1
Seismic Analysis of 6", 8" and TM149B 30" Butterfly Valve Assemblies, 1/11/78 3CC-F120A Fisher Controls 1
Seismic Analysis 1", 16" F121B and 24" Butterfly Valve F122A Assemblies, 11/17/80 F123B 3CC-F132A/B Fisher Controls 3
Dynamic Test Program on Bettis F133A/B T312-SR3 M3 and 722C-SR-80-M3-Actuators, 6/5/79 2HV-B150B Fisher Controls 3
Dynamic Test Program on Bettis B151A T420-SR3 M3 and 722C-SR80-M3 B152A Actuators, 9/18/78.
B153B Operability study in B154B accordance with NUREG-0737, B155A Action Item II.E.4.2.
Documented via LP&L letter W3P81-1835, D.L.
Aswell to R.L. Tedesco, dated August 19, 1981.
Seismic Analysis of 6", 16" B157B and 24" Butterfly Valve Assemblies, 11/17/80 3HV-B175A Fisher Controls 1
Seismic Analysis of 6", 16" B176B and 24" Butterfly Valve Assemblies, 11/17/80 3HV-B196A Fisher Controls 1
Seismic Analysis of 8", 18" B197B and 20" Butterfly Valve B198A Assemblies Rev 2, 2/13/80 B199B B200B B201A B202B B203A 3HV-B169A Fisher Controls 1
Seismic Analysis of 12" and B170B 16" Butterfly Valve Assemblies, 11/17/78
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 3 of 12)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 3HV-B171A Fisher Controls 1
Seismic Analysis of 12" and B172B 16" Butterfly Valve B177A Assemblies, 11/17/78 B178B 3HV-B206A Fisher Controls 1
Seismic Analysis of 8", 18" B207B and 20" Butterfly Valve B208A Assemblies Rev 2, 3/13/80 B209B 3HV-B226A Fisher Controls 4
Dynamic Test Program on B227B Bettis T420-SR1-M3 Actuator Rev 1, 9/18/78 2MS-V611A Anchor Darling 1
Anamet Lab No. 79.097, 7/30/79 V612B Note: Meets intent of Reg.
Guide 1.48 2SI-V801B Anchor Darling 1
A/DV Seismic Calculation V802B No. 1980-1 Rev A, 7/18/80 V809A V810A V811B 2SI-V305B Anchor Darling 1
A/DV Seismic Calculation V306A No. 1982-1, 9/1/76 V307A V308B 2SI-V1534 Anchor Darling 1
Anamet Lab No. 78.102, V1557 7/14/78 V1558 2SI-V1556 Anchor Darling 1
Anamet Lab No. 78.101, V1559 Rev A, 3/28/80 2FW-V823A Anchor Darling 1
A/DV Static Seismic Analysis V824B Report No. E-6326-1, 4/26/78
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 4 of 12) Revision 11-B (06/02)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 2SI-V326B Anchor Darling 1
A/DV Seismic Calculation V327A No. 1984-1, 9/1/76 2CS-V301A Anchor Darling 1
A/DV Seismic Analysis V302B Calculation 1985-1, 9/1/76 V303A V304B
(DRN 02-387) 2BD-F603 (BD-102A)
A/DV Calculation Order 2BD-F605 (BD-102B)
EZ901, 3/11/97 (Valve)
Hiller Seismic and EQ Report ER-ST-2400 3/21/97 (Actuator) 2BD-F604 (BD-103A)
Masoneilan 1
Masoneilan Report No.
F606 (BD-103B) 9614-01, 2/24/97 3CC-F268A Jamesbury 1
John Henry Associates Report F269B No. JHA-76-51, 4/19/77 3CC-B201A Jamesbury 1
John Henry Associates Report B203B No. JHA-77-84, 11/23/77 3CC-B262B Jamesbury 1
John Henry Associates Report B265A No. JHA-76-51, 4/19/77 3CC-F154A1 Jamesbury 1
John Henry Associates Report F155A2 No. JHA-76-5, 4/19/77 F156B1 F157B2 3CC-F158A1 Jamesbury 1
John Henry Associates Report F159A2 No. JHA-76-51, 4/19/77 F160B1 F161B2 2CC-F147A/B Jamesbury 1
John Henry Associates Report F243A/B No. JHA-76-51, 4/19/77
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 5 of 12)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 3CC-F276A Jamesbury 1
John Henry Associates Report F277B No. JHA-76-51, 4/19/77 3CC-F278A Jamesbury 1
John Henry Associates Report F279B No. JHA-76-51, 4/19/77 3CC-F130A Jamesbury 1
John Henry Associates Report F131B No. JHA-76-51, 4/19/77 3CC-F272A Jamesbury 1
John Henry Associates Report F272B No. JHA-76-51, 4/19/77 3CC-F274A Jamesbury 1
John Henry Associates Report F273B No. JHA-76-51, 4/19/77 2CC-F146A/B Jamesbury 1
John Henry Associates Report No. JHA-76-51, 4/19/77 3AC-F142A Fisher Controls 1
Dynamic Test Program on Bettis F143B T312-SR3-M# and 722C-SR80-M#
F149A Actuators, 6/5/79 F150B 3AC-F144A Jamesbury 1
John Henry Associates Report F135B No. JHA 77-86, 11/23/77 F136A F151B 3CC-F240A Masoneilan 3
Seismic Qualification Report F241B No. 1065, 1/4/80 2FW-V853A Masoneilan 3
Seismic Qualification Report V850B No. 1063, 12/13/79 V854B V849A V847B V848A V851B V852A
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 6 of 12) Revision 9 (12/97)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date
3AC-TM163A Masoneilan 3
Seismic Qualification Report TM172B No. 1064, 12/14/79
3AC-TM680A Masoneilan 3
Seismic Qualification Report TM684B No. 1062, 12/13/79 3AC-TM646A Masoneilan 3
Seismic Qualification Report TM649A No. 1062, 12/13/79 2CS-F305A W-K-M 2
National Frequency Determina-F306B tion and Seismic Analysis 15-0074-11 Rev N929, 2/21/80 Seismic Operability Qualification Test Report 15-0074-09 Rev N974, 8/15/79 1CH-F2501A/B W-K-M 2
National Frequency Calculation ASK 274557 Rev N790 Seismic Operability Qualification Test Report 15-0076-02 Rev N888 1CH-F1518A/B W-K-M 2
Natural Frequency Calculation ASK 274557 Rev N790 2MS-V602A W-K-M 2
Natural Frequency V604B Determination and Seismic Analysis ASK 274891 Rev N791, 3/2/79 Seismic Operability Qualification Test Report 15-0068-04 Rev N944, 19/17/79 Seismic Simulation Test Within Pump Module 15-0068-05 Rev N968, 11/8/79
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 7 of 12) Revision 8 (5/96)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 2IA-F601A/B W-K-M 1
Natural Frequency Calculation ASK 272968 Rev N717, 11/13/78 Static Seismic Calculation ASK 272668 Rev N715, 11/8/78 2FP-F127 W-K-M 2
Natural Frequency Calculation F129 ASK 272158 Rev N710, 9/29/78 Static Seismic Calculation ASK 272151 Rev N710, 9/27/78 Natural Frequency Calculation Verification Report ASK 272157 Rev N689, 9/27/78 Proof of Operability Test ASK 272156 Rev N689, 9/27/78 3CC-V251A Pacific 1
Seismic Analysis Report V252B FA-5262, 8/26/77 2BM-F108A/B ITT Grinnell 1
Seismic Report W-146, Rev 1, F109A/B 7/79 2MS-V663 Velan 1
Seismic Analysis B62-1500, V664 G-100 SR-6209, 8/13/74 V670 V671
1SI-V2504 Anchor 1
Report No. R95.040, V2505 Darling Rev. A 5/22/95
2MS-PM629A Control Components 1
Seismic Analysis Report PM630B International 17285-11, 11/9/78 2HV-V180A GPE Controls 1
Stress Analysis for Seismic V181B and Operating Conditions LA-240-384 Rev A, 3/15/78 Static and Dynamic Analysis LA-240-431 Rev 0, 5/31/78 1CH-F2503A Target Rock 1
Seismic and Design Report F2504B No. 3096 Rev A, 8/19/82 F2505A F2505B
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 8 of 12) Revision 10 (10/99)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date
No. 6090, Rev. A with E2558 Att. C, Rev. A, 2/25/97
E2559 E2560 E2561 E2562 KSV-72-10 Cooper Engine Co.
Qualified with Diesel 58-4 Generator, Refer to Sub-section 8.3.1.1.2.13 7FS-V129 ITT Grinnell 1
Seismic Analysis Report V130 No. W-146, Rev 1, V131 3/22/79 7CC-V258 Anchor Darling 1
Anamet Lab No.80-278, 11/7/80 2HV-V182A GPE Controls 1
Stress Analysis for Seismic V183B and Operating Conditions, LA-240-385, 3/7/77 2HV-V184A GPE Controls 1
Stress Analysis for Seismic V185B and Operating Conditions, LA-240386, 3/7/77 2SI-E1587A Target Rock 1
Seismic Analysis Certification E1588B Submitted by Target Rock letter dated 6/24/82 and Design and Seismic Report 3096, Rev A, 10/8/81 2SI-V1561A/B Anchor Darling 1
Design and Analysis Report No. R95.040, Rev. A 5/22/95
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 9 of 12)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 2SI-E632 Valcor 1
Stress Analysis Report on E633 Valve, Solenoid 1 in, Sch 80, E634 Position Indication P/N E635 104146001, Document No.
E636 Mr 526-5295-7-1, 7/17/80 E637 E638 E639 3CC-FM138A/B Fisher Controls 1
Seismic Analysis of 4", 12",
20" and 24" Butterfly Valve Assemblies, Rev 2, 1/30/80 3CC-E640A Valcor 1
Stress Analysis Report on E641B Valve, Solenoid, 1 in, Sch 80, Position Indication, Nuclear Service, DC, P/N14321001, Document No. Mr 526-6131-5-1, 8/29/80 3AC-E611A Valcor 1
Stress Analysis Report on E612B Valve, Solenoid, 1 in, Sch 80, E613A/B Position Indication, Nuclear Service, AC, P/N 101170001, Document No. Mr 526-5295-6-1 7/17/80 3HV-B210A Jamesbury 1
John Henry Associates Report No. JHA-77-84, 11/23/77 3HV-B215B Jamesbury 1
John Henry Associates Report B216A No. JHA-77-84, 11/23/77 3HV-B217B Fisher Controls 3
Dynamic Test Program on Bettis B218A T420-SR3-M3 and 722-SR-80-M3 Actuators, 9/18/78 3HV-B223B Fisher Controls 3
Dynamic Test Program on Bettis B224A T420-SR3-M3 and 722-SR-80-M3 Actuators, 9/18/78
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 10 of 12)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 3HV-B225B Fisher Controls 3
Dynamic Test Program on Bettis T312-SR3-M3 and 722C-SR-80-M3 Actuators, 6/5/79 3MS-V684 Velan 1
Seismic Analysis of 2" Carbon V685 Steel Valve Report No. SR6209, Rev 1, 8/13/74 2MS-F714 Velan 1
Seismic Analysis 1" F715 Bonnetless Vertical Globe Valve SR-6622, 6/4/81 2HV-F253A Fisher Controls 1
Seismic Analysis of 4", 10" F254B and 12" Butterfly Valve Assem-blies, Rev 2, 1/30/80 2HV-B167A Fisher Controls 1
Seismic Analysis of 4", 12" B168B 20" and 24" Butterfly Valve Assemblies, Rev 2, 1/30/80 2HV-B164A Fisher Controls 1
Seismic Analysis of 6", 8" and B165B 30" Butterfly Valve Assem-blies, 1/11/78 2HV-B158A Fisher Controls 1
Seismic Analysis of 6", 8" and B159B 30" Butterfly Valve Assem-B160A blies, 1/11/78 B161B B162QA B163B 2HV-B173A Fisher Controls 1
Seismic Analysis of 4", 12",
B174B 20" and 24" Butterfly Valve Assemblies, Rev 2, 1/30/80 2WM-F104A/B ITT Grinnell 1
Seismic Report W-146, Rev 1, F105A/B 7/79, App L 2WM-F157A/B ITT Grinnell 1
Seismic Report W-146, Rev 1, 7/79, App I
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 11 of 12)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 2SL-V601 Velan 1
Seismic Analysis 1/2" V602 Bonnetless Vertical Globe V603 Valve 6576, 4/23/81 V604 2SL-F1501A/B W-K-M 1
Natural Frequency Calculation F1502A/B ASK 272970, Rev N717 F1503A/B Static Seismic Calculation F1504A/B ASK 272667, Rev N715, 11/8/78 F1505A/B F1506A/B 3NG-E671-1 Target Rock 3
1" Solenoid Valve, E671-2 Model 7CC-001, E671-3 Report No 2375B, E671-4 9/26/79 E671-5 E671-6 E671-7 E671-8 3NG-P670-1 Target Rock 1
Seismic Analysis and Design P670-2 Report No. 3052, Rev A, P670-3 8/5/82 P670-4 P670-5 P670-6 P670-7 P670-8 2HA-E601A Valcor 1
Stress Analysis Report on E602A Valve, Solenoid, 3/8 in, Tube E603A
.065 THK, Position Indication E604A Nuclear Service, AC, E605A P/N 103220002 Document No.
E606A Mr 526-6002-5-1, 7/17/80; E607A P/N 103140002 Document No.
E608A Mr 526-5295-9-1, 7/17/80; E609A P/N 103170002 Document No.
E610A Mr 526-05295-15-1, 7/17/80
WSES-FSAR-UNIT-3 TABLE 3.9C-1 (Sheet 12 of 12)
Revision 309 (06/16)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED ACTIVE VALVE OTHER THAN CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 2HA-E621B Valcor (Cont'd)
E622B E623B E624B E625B E626B E627B E628B E629B E630B E633A E634B (LBDCR 15-013, R309) 3CC-TM169A/B Valtek 1
Seismic Analysis of 6" Globe Valve Valtek Qualification Report 108220.001 Rev 0 09/22/95 (LBDCR 15-013, R309) 3CC-B187A/B Jamesbury 1
John Henry Associates Report N, JHA-76-51, 4/19/77 2CH-F1512A/B WKM 1
Natural Frequency Calculation, F1513A/B ASK 272970, Rev N717, 11/10/80 Static Seismic Calculations, ASK 272667, Rev N715, 11/8/78 2CH-F1529A/B WKM 1
Natural Frequency Determination and Seismic Analysis 15-0074-15, Rev P274, 1/10/81 2CH-F1543 Masoneilan 1 and 4 Seismic Qualification N-00214, No. 1131, 3/11/82 2CH-F175A/B WKM 1
Natural Frequency Calculation, ASK 272657, Rev N720, 10/2/78 Static Seismic Calculation ASK 272656, Rev N710, 10/24/78 3CC-B288A Jamesbury 1
Neles - Jamesbury Report 3CC-B289B No. SWLA - DS98698 Rev. A 12/3/96 (EC-14765, R305)
SIMVAAA4052A Valcor 1
Valcor Report SIMVAAA4052B Valcor 1
MR 526-6040-22-1 dated 12/17/00 (EC-14765, R305)
WSES-FSAR-UNIT-3 TABLE 3.9C-2 Revision 304 (06/10)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED CLASS 1 CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date (EC-13981, R304) 1SI-V1509RL1A Anchor Darling /
1 Anamet Lab No. 676.4, V1511RL1B Flowserve 6/30/76 V1513RL2A Flowserve-RAL No.
(DRN 06-882, R15) 20343 R-0 Dated V1515RL2B 6-25-09 (SQ-MN-13) 1SI-V1513 (SI 336A) Only (DRN 06-882, R15; EC-13981, R304) 1SI-V1510TK1A Anchor Darling 1
Anamet Lab No. 78.178 V1512TK1B Rev. A, 9/10/79 V1516TK2B (DRN 06-882, R15)
V1514TK2A Anchor Darling 1
Anamet Lab No. 676.4, (DRN 06-882, R15) 6/30/76 (DRN 06-882, R15) 1SI-V1522RL1A Anchor Darling Not Valves Smaller than 4 Required in diameter. No extended topworks.
(DRN 06-882, R15)
V1523RL1B (DRN 06-882, R15)
V1524RL2A (DRN 06-882, R15)
V1525RL2B (DRN 00-1077) 1SI-V2506 Flowserve 1
Design and Seismic V2507 Analysis Report for 3 V2508
-2500# Tilt Disc Check V2509 Valve; Report No.
TR00.067 (DRN 00-1077) 1CH-V2502-1 Velan 1
Extension of Seismic V2502-2 Analysis SR-6686, V2502-3 12/10/81, Seismic V2502-4 Analysis SR-6553, 3/2/81 (DRN 02-387, R11-B) 1SI-V1517RL1A Anchor Darling 1
Anamet Lab No. 676.3 V1518RL1B or (For Flowserve - Log No.
V1519RL2A Flowserve TR01.091)
V1520RL2B (DRN 02-387, R11-B)
WSES-FSAR-UNIT-3 TABLE 3.9C-3 (1 of 2)
Revision 304 (06/10)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED CLASS 1 CHECK VALVES Valve Tag No.
Manufacturer Qualification Method Report No. and Date 3CC-V229A V231B TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 (DRN 98-1951, R11) 3CC-V286A V287B TRW Mission/
Atwood & Morrill 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 (DRN 98-1951, R11) 3CC-V101A V102B V103A/B TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 3CC-V204B V202A TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 3CC-V280A V281B TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 3CC-V282A V283A TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 3CC-V176A V177B V178A V179B TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 2CC-V242A/B TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 3FW-V601A V602B TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 (DRN 99-0691; EC-19716, R304) 3FW-V603A/B TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 (DRN 99-0691; EC-19716, R304) 3MS-V676A V677A TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 2FP-V128 V130 TRW Mission 1
Seismic Stress Analysis MVP 3374 Revision 3/18/77 2SI-V331A V332B TRW Mission 1
Seismic Stress Analysis MVP 4212 and 39132 Revision 3/3/77
WSES-FSAR-UNIT-3 TABLE 3.9C-3 (2 of 2)
Revision 13 (04/04)
SEISMIC QUALIFICATION REPORTS FOR NON-NSSS SUPPLIED CLASS 1 CHECK VALVES Qualification Valve Tag No.
Manufacturer Method Report No. and Date 2SI-V315A V316B TRW Mission 1
Seismic Stress Analysis MVP 4212 and 39132 Revision 3/3/77 2SI-V105A V106B V107A V108B TRW Mission 1
Seismic Stress Analysis MVP 4212 and 39132 Revision 3/3/77 3SI-V117B V118A TRW Mission 1
Seismic Stress Analysis MVP 4212 and 39132 Revision 3/3/77
¨(DRN 02-1196, R13)
ACC-1045A 1045B BNL Industries 1
Seismic Analysis Report No.
SA-A020504, Rev. 0 (DRN 02-1196, R13)
ACC-1951A 1051B BNL Industries 1
Seismic Analysis Report No.
SA-A960904-6 Rev. 0