WSES-FSAR-UNIT-3 2-i Revision 307 (07/13)

SITE CHARACTERISTICS CHAPTER 2 TABLE OF CONTENTS Section Title Page 2.0 SITE CHARACTERISTICS 2.1-1 2.1 GEOGRAPHY AND DEMOGRAPHY 2.1-1 2.1.1 SITE LOCATION AND DESCRIPTION 2.1-1 2.1.2 EXCLUSION AREA AUTHORITY AND CONTROL 2.1-3 2.1.3 POPULATION DISTRIBUTION 2.1-5

2.1 REFERENCES

2.1-24 NEARBY INDUSTRIAL, TRANSPORTATION AND MILITARY 2.2-1 FACILITIES 2.2.1 LOCATIONS AND ROUTES 2.2-1 2.

2.2 DESCRIPTION

S 2.2-1 (EC-39014, R307) 2.2.3 EVALUATION OF POTENTIAL ACCIDENTS 2.2-11 (EC-39014, R307)

2.2 REFERENCES

2.2-57 2.2A EVALUATION OF ACTUAL HAZARDOUS CHEMICAL RELEASES 2.2A-1 POSTULATED TO OCCUR NEAR THE WATERFORD 3 SITE 2.2A.1 ANALYSIS OF THE POSSIBLE CONSEQUENCES OF THE 2.2A-1 LIVINGSTON, LOUISIANA DERAILMENT ACCIDENT ON THE WATERFORD 3 PLANT 2.2A.2 ANALYSIS OF THE POTENTIAL CONSEQUENCES OF THE 2.2A-7 DECEMBER 11, 1982 EXPLOSION AT THE UNION CARBIDE PLANT ON WSES-3 2.2A REFERENCES 2.2A-10 2.3 METEOROLOGY 2.3-1 2.3.1 REGIONAL CLIMATOLOGY 2.3-1 2.3.2 LOCAL METEOROLOGY 2.3-6 2.3.3 ONSITE METEOROLOGICAL MEASUREMENTS PROGRAM 2.3-9

WSES-FSAR-UNIT-3 2-ii CHAPTER 2 TABLE OF CONTENTS (Cont'd)

Section Title Page 2.3.4 SHORT-TERM (ACCIDENT) DIFFUSION ESTIMATES 2.3-17 2.3.5 LONG TERM (ROUTINE) DIFFUSION ESTIMATES 2.3-20

2.3 REFERENCES

2.3-22 2.4 HYDROLOGIC ENGINEERING 2.4-1 2.4.1 HYDROLOGIC DESCRIPTION 2.4-1 2.4.2 FLOODS 2.4-5 2.4.3 PROBABLE MAXIMUM FLOOD (PMF) ON STREAMS AND 2.4-12 RIVERS 2.4.4 POTENTIAL DAM FAILURES, SEISMICALLY INDUCED 2.4-20 2.4.5 PROBABLE MAXIMUM SURGE AND SEICHE FLOODING 2.4-20 2.4.6 PROBABLE MAXIMUM TSUNAMI FLOODING 2.4-32 2.4.7 ICE EFFECTS 2.4-32 2.4.8 COOLING WATER CANALS AND RESERVOIRS 2.4-33 2.4.9 CHANNEL DIVERSIONS 2.4-33 2.4.10 FLOODING PROTECTION REQUIREMENTS 2.4-33 2.4.11 LOW WATER CONSIDERATION 2.4-34 2.4.12 DISPERSION, DILUTION, AND TRAVEL TIMES OF 2.4-36 ACCIDENTAL RELEASES OF LIQUID EFFLUENTS IN SURFACE WATERS 2.4.13 GROUNDWATER 2.4-37 2.4.14 TECHNICAL SPECIFICATIONS AND EMERGENCY OPERATION 2.5-51 REQUIREMENTS

2.4 REFERENCES

2.4-52 2.5 GEOLOGY AND SEISMOLOGY 2.5-1 2.5.1 BASIC GEOLOGIC AND SEISMIC INFORMATION 2.5-2 2.5.2 VIBRATORY GROUND MOTION 2.5-41

WSES-FSAR-UNIT-3 2-iii CHAPTER 2 TABLE OF CONTENTS (Cont'd)

Section Title Page 2.5.3 SURFACE FAULTING 2.5-52 2.5.4 STABILITY OF SUBSURFACE MATERIALS 2.5-58 2.5.5 STABILITY OF SLOPES 2.5-103 2.5.6 EMBANKMENTS AND DAMS 2.5-103

2.5 REFERENCES

2.5-104 2.5 BIBLIOGRAPHY 2.5-111 2.5A LABORATORY TESTING 2.5A-1 2.5A GENERAL SAMPLE HANDLING 2.5A-1 2.5A.1 CLASSIFICATION TESTS 2.5A-1 2.5A.2 STRENGTH TESTS 2.5A-2 2.5A.3 CONSOLIDATION TESTS 2.5A-4 2.5A.4 ELASTIC PROPERTIES 2.5A-4 2.5A.5 LIQUEFACTION TESTS 2.5A-5 2.5A.6

SUMMARY

OF TESTS RESULTS 2.5A-5 2.5B BORING LOGS 2.5B-1 2.5C PROCEDURE FOR SOILS CONTROL AND FILTER 2.5C-0 AND BACKFILL SPECIFICATION

WSES-FSAR-UNIT-3 2-iv CHAPTER 2 SITE CHARACTERISTICS LIST OF TABLES Table Title 2.1-1 Resident Population Within 50 Miles of Waterford 3 2.1-2 Towns With Over 1,000 Persons Within 10 Miles of Waterford 3 2.1-3 Cities, Towns, and Communities With Over 10,000 Persons Within 50 Miles of Waterford 3 2.1-4 Total Estimated Peak Daily And Seasonal Transient Population 1977 and 2030 2.1-5 Peak Daily and Seasonal Transient Population Within 10 Miles Of Waterford 3 2.1-6 Estimated Average Sunday Participation In Recreational Activity Within 10 Miles of Waterford 3 2.1-7 Combined Daily And Seasonal Recreational Transient Population Within 10 Miles Of Waterford 3 2.1-8 Transportation Transient Population Within 10 Miles Of Waterford 3 (passengers per day) 2.1-9 Peak Daily Industrial Employment Within 10 Miles Of Waterford 3 2.1-10 Cumulative Population Density By Sectors Within 30 Miles Of Waterford Unit 3, 1981 2.1-11 Cumulative Population Density By Sectors Within 30 Miles of Waterford Unit 3, 2030 2.1-12 Major Transportation Facilities Within the LPZ 2.1-13 1977 Peak Daily Population Distribution Within The Low Population Zone 2.1-14 Summary Comparison Of Demographic Methodologies 2.1-15 Correlation And Regression Of Growth Rates Versus Development Suitability Within Five Miles Of Waterford 3, 1973-1977 2.1-16 Probability Of Residential Development Within Different Levels Of Development Suitability

WSES-FSAR-UNIT-3 2-v Revision 309 (06/16)

CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.2-1 Major Industries Within Five Miles Of Waterford 3 2.2-2 Truck Traffic Accidents In The Vicinity Of Waterford 3 (1974-1986) 2.2-3 Products Used, Produced, Stored, By Industries Within Five Miles Of Waterford 3 (EC-5000082218, R301) 2.2-3a Industrial Facilities Storing Significant Quantities of Toxic Materials Within Five Miles of Waterford 3 2.2-3b Hazardous Materials Stored or Processed in the Waterford 3 Vicinity 2.2-3c Hazardous Materials Shipped on the Mississippi River by Industrial Facilities in the Waterford 3 Vicinity (EC-39014, R307; LBDCR 15-048, R309))

2.2-3d Hazardous Materials Carried on Union Pacific Railroad in 2014 in the Vicinity of Waterford 3 2.2-3e Hazardous Materials Carried Through Good Hope, LA in 2014 on Canadian National Railway 2.2-3f Hazardous Materials Carried on Kansas City Southern Railway Through St.

Charles Parish in 2014 (EC-39014, R307, LBDCR 15-048, R309))

(EC-38835, R307) 2.2-3g Hazardous Materials Shipped by Truck on Louisiana Highway 18 in Waterford 3 Vicinity (EC-38835, R307) 2.2-4 Deleted 2.2-4a Materials Transported New Waterford 3 Posing Potential Hazards 2.2-4b Deleted (EC-39014, R307, LBDCR 15-048, R309))

2.2-5 Hazardous Freight Transported on the Mississippi River Between River Mile 129 and 129.9 in 2013 (EC-39014, R307, LBDCR 15-048, R309) 2.2-6 Major Pipelines Carrying Hazardous Materials Within Two Miles of Waterford 3 2.2-7 Oil And Gas Fields Within Five Miles Of Waterford 3 (EC-5000082218, R301) 2.2-8 Trips and Drafts Of Vessels On The Mississippi River, Between Baton Rouge To, But Not Including, New Orleans, La., 1975 2.2-9 Commercial Vessel Casualties On The Mississippi River Between Mile 124 and 135 Reported In Fiscal Year 1976 2.2-10 Mississippi River Terminals, Docks, Mooring Locations And Warehouses In The Vicinity Of Waterford 3 2.2-11 Forecast Of Aircraft Operations For The St. John The Baptist Parish Airport

WSES-FSAR-UNIT-3 2-vi Revision 307 (07/13)

CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.2-12 Aircraft Operations For New Orleans International Airport 2.2-13 Aircraft Operations Forecasts For New Orleans International Airport 2.2-14 Aircraft Accidents Occurring On Or Within Five Miles Of New Orleans International Airport, 1966-1976 2.2-15 Vessel Casualties On The Mississippi River Between New Orleans And Baton Rouge Fiscal Years 1969-1971 2.2-16 Time and Drafts Of Vessels Mississippi River - Baton Rouge, La.,

But Not Including New Orleans, La., 1970 2.2-17 Rail, Truck And Barge Accident Probability 2.2-18 Centerline Concentrations For Methane Plume Of 67 LBM/Sec Source, Stability Class F, Wind Speed 2.6 Ft./Sec Assuming No Buoyancy 2.2-19 Releases From Ruptured Pipelines 2.2-20 Dimension of Propane Plume Downwind of 325 Ft3/Sec Source (6 In. LPG Line) Stability Category F, Wind Speed 2.6 Ft/Sec 2.2-21 Dimension of Propane Plume Downwind of 1000 Ft/Sec Source, (8 In. LPG Line) Stability Category F, Wind Speed 2.6 Ft/Sec 2.2-22 Blast And Seismic Parameters For Shock Waves From Propane Detonations (EC-38835, R307) 2.2-23 Dimension Of Methane Plume Downwind Of 2893 Ft3/Sec Source Stability Category F, Wind Speed 2.6 Ft/Sec. No Buoyancy (EC-38835, R307) 2.2A-1 Toxic Chemicals Lost In Train Derailment 2.2A-2 Chemical Released In Derailment Posing Potential Hazards To Control Room Habitability 2.2A-3 Waterford Steam Electric Station Unit 3 Onsite Meteorological Data: 1972-1978 Summary of Maximum Persistence Occurrences 2.2A-4 Calculational Assumptions Used in Acrolein Release Analysis 2.3-1 Recurrence Interval And Wind Speed (Fastest Mile) At New Orleans, Louisiana (At 30 Ft.)

2.3-2 Fastest Mile Wind Speed And Wind Direction New Orleans, Louisiana

WSES-FSAR-UNIT-3 2-vii CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-2(a)

Ultimate Heat Sink Meteorological Design Parameters 2.3-3 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-4 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-5 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-6 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-7 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-8 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-9 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-10 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-11 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-12 New Orleans, La. Moisant International Airport Percentage Frequencies Of Wind Direction And Speed 2.3-13 New Orleans, La. Moisant International Airport Percentage Frequencies of Wind Direction and Speed 2.3-14 New Orleans, La. Moisant International Airport Percentage Frequencies of Wind Direction and Speed 2.3-15 New Orleans, La. Moisant International Airport Percentage Frequencies of Wind Direction and Speed 2.3-15a New Orleans, La. Moisant International Airport Percentage Frequencies of Wind Direction and Speed 2.3-16

[Wind Rose Data for January] 1973-1975 and 1978 at Waterford 3 Site 2734. Observations

WSES-FSAR-UNIT-3 2-viii CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-17

[Wind Rose Data for February] 1973-1975 and 1977-1978 at Waterford 3 Site 2585. Observations 2.3-18

[Wind Rose Data for March] 1973-1975 and 1977 at Waterford 3 Site 2706. Observations 2.3-19

[Wind Rose Data for April] 1973-1975 and 1977 at Waterford 3 Site 2751. Observations 2.3-20

[Wind Rose Data for May] 1973-1975 and 1977 at Waterford 3 Site 2790. Observations 2.3-21

[Wind Rose Data for June] 1973-1975 and 1977 at Waterford 3 Site 2716. Observations 2.3-22

[Wind Rose Data for July] 1972-1974 and 1977 at Waterford 3 Site 2886. Observations 2.3-23

[Wind Rose Data for August] 1972-1974 and 1977 at Waterford 3 Site 2746. Observations 2.3-24

[Wind Rose Data for September] 1972-1974 and 1977 at Waterford 3 Site 2616. Observations 2.3-25

[Wind Rose Data for October] 1972-1974 and 1977 at Waterford 3 Site 2647. Observations 2.3-26

[Wind Rose Data for November] 1972-1974 and 1977 at Waterford 3 Site 2731. Observations 2.3-27

[Wind Rose Data for December] 1972-1974 and 1977 at Waterford 3 Site 2843. Observations 2.3-28 Annual Wind Rose Data for July 1972-June 1975 and February 1977-February 1978 at Waterford 3 Site 32751. Observations 2.3-29 Average Monthly And Annual Temperature For Selected Stations In The New Orleans Areas (1931-1960) 2.3-30 Mean Monthly And Annual Maximum, Minimum, Average Temperatures Moisant International Airport (1931-1960) 2.3-31 Temperature Extremes, Moisant International Airport, New Orleans, Louisiana 2.3-32 Average Monthly Occurrences Of Extreme Temperatures Moisant International Airport, New Orleans, Louisiana (1947-1972)

WSES-FSAR-UNIT-3 2-ix CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-33 Mean Monthly And Annual Maximum, Minimum And Average Temperatures Waterford Nuclear Unit 3 On Site Data (July 1972-June 1975 And February 1977-February 1978) 2.3-34 Mean Relative Humidity And Number Of Days With Heavy Fog Moisant International Airport, New Orleans, Louisiana (1949-1972) 2.3-35 Average Monthly And Annual Precipitation For Selected Stations In The New Orleans Areas (1931-1960) 2.3-36 Extreme Monthly And Daily Precipitation (Inches) (1947-1972)

And Mean Number Of Days With Rain (1947-1972) Moisant International Airport, New Orleans, Louisiana 2.3-37 Maximum Short Period Precipitation (Inches) Audubon Station, New Orleans, Louisiana (1889-1969) 2.3-38 Number Of Precipitation Occurrences By Hour Of Day For Moisant International Airport (1951-1960) 2.3-39 Annual And Seasonal Percentage Frequency Of Surface Wind Direction During Precipitation Naval Air Station-New Orleans, Louisiana, (1949-1965) 2.3-40 Percent Frequency Of Onsite Stability Classes July 1972 -

June 1975 And February 1977 - February 1978 2.3-41 Seasonal And Annual Average Morning And Afternoon Mixing Heights Waterford Area 2.3-42 Wind Distribution By Stability Class At Waterford 3, January Class A 2.3-43 Wind Distribution By Stability Class At Waterford 3, January Class B 2.3-44 Wind Distribution By Stability Class At Waterford 3, January Class C 2.3-45 Wind Distribution By Stability Class At Waterford 3, January Class D 2.3-46 Wind Distribution By Stability Class At Waterford 3, January Class E 2.3-47 Wind Distribution By Stability Class At Waterford 3, January Class F

WSES-FSAR-UNIT-3 2-x CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-48 Wind Distribution By Stability Class At Waterford 3, January Class G 2.3-49 Wind Distribution By Stability Class At Waterford 3, February Class A 2.3-50 Wind Distribution By Stability Class At Waterford 3, February Class B 2.3-51 Wind Distribution By Stability Class At Waterford 3, February Class C 2.3-52 Wind Distribution By Stability Class At Waterford 3, February Class D 2.3-53 Wind Distribution By Stability Class At Waterford 3, February Class E 2.3-54 Wind Distribution By Stability Class At Waterford 3, February Class F 2.3-55 Wind Distribution By Stability Class At Waterford 3, February Class G 2.3-56 Wind Distribution By Stability Class At Waterford 3, March Class A 2.3-57 Wind Distribution By Stability Class At Waterford 3, March Class B 2.3-58 Wind Distribution By Stability Class At Waterford 3, March Class C 2.3-59 Wind Distribution By Stability Class At Waterford 3, March Class D 2.3-60 Wind Distribution By Stability Class At Waterford 3, March Class E 2.3-61 Wind Distribution By Stability Class At Waterford 3, March Class F 2.3-62 Wind Distribution By Stability Class At Waterford 3, March Class G 2.3-63 Wind Distribution By Stability Class At Waterford 3, April Class A

WSES-FSAR-UNIT-3 2-xi CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-64 Wind Distribution By Stability Class At Waterford 3, April Class B 2.3-65 Wind Distribution By Stability Class At Waterford 3, April Class C 2.3-66 Wind Distribution By Stability Class At Waterford 3, April Class D 2.3-67 Wind Distribution By Stability Class At Waterford 3, April Class E 2.3-68 Wind Distribution By Stability Class At Waterford 3, April Class F 2.3-69 Wind Distribution By Stability Class At Waterford 3, April Class G 2.3-70 Wind Distribution By Stability Class At Waterford 3, May Class A 2.3-71 Wind Distribution By Stability Class At Waterford 3, May Class B 2.3-72 Wind Distribution By Stability Class At Waterford 3, May Class C 2.3-73 Wind Distribution By Stability Class At Waterford 3, May Class D 2.3-74 Wind Distribution By Stability Class AT Waterford 3, May Class E 2.3-75 Wind Distribution By Stability Class AT Waterford 3, May Class F 2.3-76 Wind Distribution By Stability Class At Waterford 3, May Class G 2.3-77 Wind Distribution By Stability Class At Waterford 3, June Class A 2.3-78 Wind Distribution By Stability Class At Waterford 3, June Class B 2.3-79 Wind Distribution By Stability Class At Waterford 3, June Class C

WSES-FSAR-UNIT-3 2-xii CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-80 Wind Distribution By Stability Class At Waterford 3, June Class D 2.3-81 Wind Distribution By Stability Class At Waterford 3, June Class E 2.3-82 Wind Distribution By Stability Class At Waterford 3, June Class F 2.3-83 Wind Distribution By Stability Class At Waterford 3, June Class G 2.3-84 Wind Distribution By Stability Class At Waterford 3, July Class A 2.3-85 Wind Distribution By Stability Class At Waterford 3, July Class B 2.3-86 Wind Distribution By Stability Class At Waterford 3, July Class C 2.3-87 Wind Distribution By Stability Class At Waterford 3, July Class D 2.3-88 Wind Distribution By Stability Class At Waterford 3, July Class E 2.3-89 Wind Distribution By Stability Class At Waterford 3, July Class F 2.3-90 Wind Distribution By Stability Class At Waterford 3, July Class G 2.3-91 Wind Distribution By Stability Class At Waterford 3, August Class A 2.3-92 Wind Distribution By Stability Class At Waterford 3, August Class B 2.3-93 Wind Distribution By Stability Class At Waterford 3, August Class C 2.3-94 Wind Distribution By Stability Class At Waterford 3, August Class D 2.3-95 Wind Distribution By Stability Class At Waterford 3, August Class E

WSES-FSAR-UNIT-3 2-xiii CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-96 Wind Distribution By Stability Class At Waterford 3, August Class F 2.3-97 Wind Distribution By Stability Class At Waterford 3, August Class G 2.3-98 Wind Distribution By Stability Class At Waterford 3, September Class A 2.3-99 Wind Distribution By Stability Class At Waterford 3, September Class B 2.3-100 Wind Distribution By Stability Class At Waterford 3, September Class C 2.3-101 Wind Distribution By Stability Class At Waterford 3, September Class D 2.3-102 Wind Distribution By Stability Class At Waterford 3, September Class E 2.3-103 Wind Distribution By Stability Class At Waterford 3, September Class F 2.3-104 Wind Distribution By Stability Class At Waterford 3, September Class G 2.3-105 Wind Distribution By Stability Class At Waterford 3, October Class A 2.3-106 Wind Distribution By Stability Class AT Waterford 3, October Class B 2.3-107 Wind Distribution By Stability Class At Waterford 3, October Class C 2.3-108 Wind Distribution By Stability Class At Waterford 3, October Class D 2.3-109 Wind Distribution By Stability Class At Waterford 3, October Class E 2.3-110 Wind Distribution By Stability Class At Waterford 3, October Class F 2.3-111 Wind Distribution By Stability Class At Waterford 3, October Class G

WSES-FSAR-UNIT-3 2-xiv CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-112 Wind Distribution By Stability Class At Waterford 3, November Class A 2.3-113 Wind Distribution By Stability Class At Waterford 3, November Class B 2.3-114 Wind Distribution By Stability Class At Waterford 3, November Class C 2.3-115 Wind Distribution By Stability Class At Waterford 3, November Class D 2.3-116 Wind Distribution By Stability Class At Waterford 3, November Class E 2.3-117 Wind Distribution By Stability Class At Waterford 3, November Class F 2.3-118 Wind Distribution By Stability Class At Waterford 3, November Class G 2.3-119 Wind Distribution By Stability Class At Waterford 3, December Class A 2.3-120 Wind Distribution By Stability Class At Waterford 3, December Class B 2.3-121 Wind Distribution By Stability Class At Waterford 3, December Class C 2.3-122 Wind Distribution By Stability Class At Waterford 3, December Class D 2.3-123 Wind Distribution By Stability Class At Waterford 3, December Class E 2.3-124 Wind Distribution By Stability Class At Waterford 3, December Class F 2.3-125 Wind Distribution By Stability Class At Waterford 3, December Class G 2.3-126 Wind Distribution By Stability Class At Waterford 3, Annual Total, Class A 2.3-127 Wind Distribution By Stability Class At Waterford 3, Annual Total, Class B

WSES-FSAR-UNIT-3 2-xv Revision 14 (12/05)

CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.3-128 Wind Distribution By Stability Class At Waterford 3, Annual Total, Class C 2.3-129 Wind Distribution By Stability Class At Waterford 3, Annual Total, Class D 2.3-130 Wind Distribution By Stability Class At Waterford 3, Annual Total, Class E 2.3-131 Wind Distribution By Stability Class At Waterford 3, Annual Total, Class F 2.3-132 Wind Distribution By Stability Class At Waterford 3, Annual Total, Class G 2.3-133 Average Monthly Data Recovery, Waterford Onsite Meteorological Monitoring Program (July 1972-June 1975 and February 1977-February 1978) 2.3-134 Waterford SES-Unit 3 Annual Average Dilution Factors (July 1972-June 1975 and February 1977-February 1978) 2.3-135 Waterford SES-Unit 3 Annual Average Dilution Factors At The Minimum Site Boundary (914m) (July 1972-June 1975 and February 1977-February 1978)

(DRN 03-2055, R14) 2.3-136 Waterford SES-Unit 3 Short-term (Accident) Dilution Factors (Sec/m

3) (1997-2001)

(DRN 03-2055, R14) 2.3-137 Storms in Excess of 50 MPH Since 1963 2.3-138 Waterford Onsite Meteorological Monitoring System 2.3-139 Summary of Meteorological Monitoring Program Parameters Measured At Primary And Backup Systems (DRN 01-156, R11-A) 2.3-140 DELETED (DRN 01-156, R11-A) 2.3-141 Waterford Operational Meteorological Monitoring System Accuracies 2.4-1 Municipal Water Intakes Downstream Of Waterford 3 Discharge (River Mile 129.6) 2.4-2 Flood-Crest Elevation Near The Waterford Site

WSES-FSAR-UNIT-3 2-xvi Revision 11 (05/01)

CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.4-3 Maximum Discharges for 1973 Flood 2.4-4 Original And Adjusted Project Design Flood Flow Lines 2.4-5 Streamflow In The Mississippi River 1900-1976 (DRN 99-2493) 2.4-6 DELETED 2.4-6a DELETED 2.4-6b DELETED 2.4-6c DELETED (DRN 99-2493) 2.4-7 Hypothetical Flood Peaks On The Mississippi And Atchafalaya Rivers 2.4-8 Computations Of Static And Dynamic Head Following Levee Failure 2.4-9 Computations Of Static And Dynamic Head 2.4-10 Probable Maximum Hurricane Parameters Zone B - Mile 660 -

New Orleans, Louisiana 2.4-10a Comparison Of Hurricane Surge Computations For South Pass Approach 2.4-11 Continental Shelf Profiles For Open Coast Surge Computations 2.4-12 Frequency Analysis Of Mississippi River Discharge Charge At Tarbert Landing 2.4-13 Water Well And Test Hole Data For St. Charles Parish 2.4-14 Local Detailed Well Survey 2.4-15 Groundwater Quality At Site 2.5-1 Approximate Periods Of Movements Along Growth Faults In Louisiana 2.5-2 Oil Well Logs Used In Structural Correlations 2.5-3 Tonal Anomalies And Linear Trends In The Site Area

WSES-FSAR-UNIT-3 2-xvii CHAPTER 2 LIST OF TABLES (Cont'd)

Table Title 2.5-4 Utilized Southern Louisiana Salt Domes 2.5-5 Salt Domes Near Waterford Site 2.5-6 Listing Of Historic Earthquakes In Order Of Distance From Waterford Site 2.5-7 Listing Of Historic Earthquakes In Order Of Decreasing Intensity 2.5-8 Listing Of Historic Earthquakes In Chronological Order 2.5-9 Summary Of Intensity Data Concerning The New Madrid Series, Donaldsonville Earthquake, Gulfport Earthquake, And Baton Rouge Earthquake 2.5-10 Results From Parametric Study Of Seismic Wave Transmission Characteristics 2.5-11 Results From Parametric Study Of Seismic Wave Transmission Characteristics 2.5-12 Pleistocene Soil Strata Zones 2.5-13 Unified Soil Classifications 2.5-14 Properties Of Subsurface Materials Design Values 2.5-15 Compacted Class A Backfill Index Properties Test Results 2.5-16 Monitoring Point Locations 2.5A-1 Laboratory Test Summary Table 2.5A-2 Summary Of Laboratory Permeability Tests 2.5A-3 Coefficient Of Permeability Computed From Consolidation Data 2.5A-4 Summary Of Organic Content Data 2.5A Notes On Tables

WSES-FSAR-UNIT-3 2-xviii SITE CHARACTERISTICS CHAPTER 2 LIST OF FIGURES Figure Title 2.1-1 THE REGION WITHIN 50 MILES OF WATERFORD 3 2.1-2 THE AREA WITHIN 5 MILES OF WATERFORD 3 2.1-3 WATERFORD 3 SITE AND NEARBY STRUCTURES 2.1-4 EFFLUENT RELEASE POINTS AND RESTRICTED AREA BOUNDARY 2.1-4a WATERFORD 3 SITE EXCLUSION ZONE AND PROPERTY BOUNDARY 2.1-5 1977 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-6 1980 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-7 1981 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-8 1990 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-9 2000 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-10 2010 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-11 2020 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-12 2030 RESIDENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-13 THE REGION WITHIN 10 MILES OF WATERFORD 3 2.1-14 1977 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-15 1980 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-16 1981 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-17 1990 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-18 2000 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-19 2010 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-20 2020 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-21 2030 RESIDENT POPULATION WITHIN 50 MILES OF WATERFORD 3 2.1-22 1977 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3

WSES-FSAR-UNIT-3 2-xix Revision 309 (06/16)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.1-23 1980 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-24 1981 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-25 1990 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-26 2000 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-27 2010 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-28 2020 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-29 2030 TRANSIENT POPULATION WITHIN 10 MILES OF WATERFORD 3 2.1-30 RECREATIONAL FACILITIES WITHIN 10 MILES OF WATERFORD 3 2.1-31 TRANSPORTATION NETWORK WITHIN 10 MILES OF WATERFORD 3 2.1-32 MAJOR INDUSTRIAL PROPERTIES WITHIN 10 MILES OF WATERFORD 3 2.1-33 LOW POPULATION ZONE CULTURAL FEATURES 2.1-34 LOW POPULATION ZONE 1977 PEAK POPULATION DISTRIBUTION 2.2-1 MAJOR INDUSTRIES AND OIL AND GAS FIELDS WITHIN 5 MILES OF WATERFORD 3 2.2-2 TRANSPORTATION FACILITIES WITHIN 5 MILES OF WATERFORD 3 (EC-5000082218, R301) 2.2-3 DELETED (EC-39014, R307; LBDCR 15-048, R309) 2.2-3A PIPELINES OF ACADIAN & ENTERPRISE PELICAN IN VICINITY OF WATERFORD 3 (LBDCR 15-048, R309) 2.2-3B PIPELINES OF AIR PRODUCTS & NUSTAR IN WATERFORD 3 VICINITY 2.2-3C PIPELINES OF CHEVRON & BRIDGELINE IN VICNITY OF WATERFORD 3 (EC-39014, R307) 2.2-3D PIPELINES OF ENTERPRISE PRODUCTS OPERATING CO. IN VICINITY OF WATERFORD 3 2.2-3E PIPELINES OF GULF SOUTH PIPELINE IN VICINITY OF WATERFORD 3 (EC-5000082218, R301)

(EC-39014, R307) 2.2-3F PIPELINES OF SHELL OIL & DCP MIDSTREAM IN VICINITY OF WATERFORD 3 2.2-3G PIPELINES OF UCAR IN VICINITY OF WATERFORD 3 (EC-39014, R307) 2.2-4 AIRPORTS AND LOW ALTITUDE FEDERAL AIRWAYS IN THE VICINITY OF WATERFORD 3 2.2-5 FIGURE NUMBER NOT USED 2.2-5A LANDING AND APPROACH PATHS, NEW ORLEANS INTERNATIONAL AIRPORT 2.2-5B LANDING AND APPROACH PATHS, NEW ORLEANS INTERNATIONAL AIRPORT

WSES-FSAR-UNIT-3 2-xx Revision 301 (09/07)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.2-6 AIR ALERT ZONE IN THE VICINITY OF WATERFORD 3 2.2-7 OVERPRESSURE VS. SCALED RANGE FOR SURFACE BURST 2.2-8 DETONABLE CLOUD FOR 6" TEXACO LPG LINE 2.2-9 DETONABLE CLOUD FOR 8" UNION CARBIDE LINE 2.2-10 BLAST WAVE PARAMETER VS. SCALED DISTANCE 2.2-11 ENTRAINMENT COEFFICIENT VS. DENSIMETRIC FROUDE NO. (FROM REFERENCE 20) 2.2-12 100 LB/SEC BREAK GRAVITY SLUMPING MODEL RESULTS 2.2-13 VOLUME DISTANCE OF 100 LB/SEC SOURCE OF WIDTH L GIVING 2.4%

CONCENTRATION 2.2-14 LATERAL DIFFUSION, Y, VS. DOWNWIND DISTANCE FROM SOURCE FOR PASQUILL'S TURBULENCE TYPES (SOURCE: REF. 71) 2.2-15 FAMILY OF HUGONIOT CURVES CORRESPONDING TO ZERO & 100 PERCENT REACTION OF STOICHIOMETRIC PROPANE AND AIR 2.2-16 OVERPRESSURES GENERATED BY DEFLAGRATIONS OF PROPANE AND HYDROGEN OXYGEN AND AIR MIXTURES 2.2-17 QUADRATIC REGRESSION LINE MAXIMUM DEBRIS DISTANCE VS.

EQUIVALENT YIELD 2.2A-1 TOPOGRAPHIC MAP OF SITE AND VICINITY 2.2A-2 PERSISTENCE OF CALMS 2.2A-3 CONDITIONAL PROBABILITY OF EXCEEDING DISTANCE FROM TRACK FOLLOWING A FREIGHT TRAIN DERAILMENT 2.2A-4 PROBABILITY OF OCCURRENCE OF POOLS OR CLOUDS OF GIVEN DIMENSION - THAT MIGHT IGNITE AND CAUSE FIRES/EXPLOSIONS (GIVEN A SPILL HAS OCCURRED) 2.2A-5 FLAME HEIGHT VS. SIZE OF FIRE 2.2A-6 PROBABILITY OF MISSILES REACHING A DISTANCE FROM ACCIDENT LOCATION 2.2A-7 QUADRATIC REGRESSION LINE MAXIMUM DEBRIS DISTANCE VS.

EQUIVALENT YIELD 2.2A-8 ACROLEIN CONCENTRATION VS. TIME 2.3-1 JANUARY WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA

WSES-FSAR-UNIT-3 2-xxi Revision 301 (09/07)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.3-2 FEBRUARY WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-3 MARCH WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-4 APRIL WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-5 MAY WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-6 JUNE WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-7 JULY WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-8 AUGUST WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-9 SEPTEMBER WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-10 OCTOBER WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-11 NOVEMBER WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-12 DECEMBER WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-13 ANNUAL WIND ROSE MOISANT INTERNATIONAL AIRPORT, NEW ORLEANS, LOUISIANA 2.3-14 ON-SITE WIND ROSE - JANUARY 1973-1975 & 1978 2.3-15 ON-SITE WIND ROSE - FEBRUARY 1973-1975 & 1977-1978 2.3-16 ON-SITE WIND ROSE - MARCH 1973-1975 & 1977 2.3-17 ON-SITE WIND ROSE - APRIL 1973-1975 & 1977 2.3-18 ON-SITE WIND ROSE - MAY 1973-1975 & 1977 2.3-19 ON-SITE WIND ROSE - JUNE 1973-1975 & 1977 2.3-20 ON-SITE WIND ROSE - JULY 1972-1974 & 1977

WSES-FSAR-UNIT-3 2-xxii CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.3-21 ON-SITE WIND ROSE - AUGUST 1972-1974 & 1977 2.3-22 ON-SITE WIND ROSE - SEPTEMBER 1972-1974 & 1977 2.3-23 ON-SITE WIND ROSE - OCTOBER 1972-1974 & 1977 2.3-24 ON-SITE WIND ROSE - NOVEMBER 1972-1974 & 1977 2.3-25 ON-SITE WIND ROSE - DECEMBER 1972-1974 & 1977 2.3-26 ON-SITE WIND ROSE - ANNUAL 1972-1975 & 1977-78 2.3-27 FIGURE NUMBER NOT USED 2.3-27a MAXIMUM TOPOGRAPHIC ELEVATION VS. DISTANCE FROM CENTERLINE OF PLANT (SHEET 1 OF 4) 2.3-27b MAXIMUM TOPOGRAPHIC ELEVATION VS. DISTANCE FROM CENTERLINE OF PLANT (SHEET 2 OF 4) 2.3-27c MAXIMUM TOPOGRAPHIC ELEVATION VS. DISTANCE FROM CENTERLINE OF PLANT (SHEET 3 OF 4) 2.3-27d MAXIMUM TOPOGRAPHIC ELEVATION VS. DISTANCE FROM CENTERLINE OF PLANT (SHEET 4 OF 4) 2.3-28 TOPOGRAPHIC FEATURES WITHIN 5 MILES OF SITE 2.3-29 LOCATION OF METEOROLOGICAL TOWER 2.3-30 W1034 LOW THRESHOLD RECORDING WIND SYSTEM 2.3-31 W1034 LOW THRESHOLD RECORDING WIND SYSTEM 2.3-32 W1034 LOW THRESHOLD RECORDING WIND SYSTEM 2.3-33 SPECIFICATIONS FOR THE GILL ANEMOMETER BIVANE -

MODEL NO. 21001 2.3-34 PHOTOGRAPH OF THE GILL ANEMOMETER BIVANE - MODEL NO. 21002 2.3-35 SPECIFICATION OF THE W101-P SKYVANE I WIND SENSOR 2.3-36 PHOTOGRAPH OF THE W101-P SKYVANE I WIND SENSOR 2.3-37 SPECIFICATIONS OF THE M731 DIGITAL DATA LOGGER 2.3-38 PHOTOGRAPH OF THE M731 DIGITAL DATA LOGGER

WSES-FSAR-UNIT-3 2-xxiii Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.3-39 HORIZONTAL DISPERSION COEFFICIENTS 2.3-40 VERTICAL DISPERSION COEFFICIENTS 2.3-41 DIRECTIONALLY INDEPENDENT - CUM. FREQUENCY DISTRIBUTION OF X/Q AT THE MIN. SITE BOUNDARY - JULY 1972 - JUNE 1975 & FEB 1977-FEB 1978 - 1 HOUR PERIOD 2.3-42 DIRECTIONALLY INDEPENDENT - CUM. FREQUENCY DISTRIBUTION OF X/Q AT THE OUTER BOUNDARY OF THE LOW POPULATION ZONE - JULY 1972-JUNE 1975 & FEB 1977 - FEB 1978 - 8 HOUR PERIOD 2.3-43 DIRECTIONALLY INDEPENDENT - CUM. FREQUENCY DISTRIBUTION OF X/Q AT THE OUTER BOUNDARY OF THE LOW POPULATION ZONE - JULY 1972-JUNE 1975 & FEB 1972 - FEB 1978 - 16 HOUR PERIOD 2.3-44 DIRECTIONALLY INDEPENDENT - CUM. FREQUENCY DISTRIBUTION OF X/Q AT THE OUTER BOUNDARY OF THE LOW POPULATION ZONE - JULY 1972-JUNE 1975 & FEB 1972 - FEB 1978 - 3 DAY PERIOD 2.3-45 DIRECTIONALLY INDEPENDENT - CUM. FREQUENCY DISTRIBUTION OF X/Q AT THE OUTER BOUNDARY OF THE LOW POPULATION ZONE JULY 1972-JUNE 1975 & FEB 1972 - FEB 1978 - 26 DAY PERIOD 2.3-46 DIAGRAM OF PRIMARY METEOROLOGICAL TOWER COMPOUND 2.3-47 LOCATIONS OF PRIMARY AND BACKUP METEOROLOGICAL MONITORING SYSTEMS (DRN 03-2055, R14) 2.3-48 SOURCE AND RECEPTOR LOCATIONS FOR CONTROL ROOM ATMOSPHERIC DISPERSION CALCULATIONS (DRN 03-2055, R14) 2.4-1 TOPOGRAPHIC MAP OF SITE AND VICINITY 2.4-2 REGIONAL HYDROGRAPHIC FEATURES 2.4-3 FLOOD CONTROL SCHEME IN THE LOWER MISSISSIPPI RIVER 2.4-4 COMPARISON BETWEEN 1973 FLOOD DISCHARGE & PDF DISCHARGE 2.4-5 SURFACE AND GROUNDWATER PUMPAGE TRENDS FOR ST. CHARLES PARISH 2.4-6 STAGE HYDROGRAPH AT RED RIVER LANDING, LA.

2.4-7 FLOOD FREQUENCY AT TARBERT LANDING AND BATON ROUGE, MISS. RIVER BY LOG-PEARSON TYPE III DISTRIBUTION 2.4-8 ROOF DRAINAGE 2.4-9 DETERMINATION OF MANNING ROUGHNESS COEFFICIENT

WSES-FSAR-UNIT-3 2-xxiv Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.4-10 PROJECT DESIGN FLOOD FLOW LINE FROM VENICE TO NEW ORLEANS 2.4-11 BONNET CARRE' SPILLWAY OPERATION 2.4-12 PROJECT DESIGN FLOOD FLOW LINE AND LEVEE DESIGN GRADE 2.4-13 FLOOD STAGE - DISCHARGE CURVE AT WATERFORD SITE 2.4-14 COMPUTED RIVER PROFILE WITH FULL LEVEE DISCHARGE 2.4-15 DELETED 2.4-16 DELETED 2.4-17 DELETED 2.4-18 DELETED 2.4-19 DELETED 2.4-20 WATERFORD 3-SITE AREA 2.4-21 WATER PROFILE UNDER SUDDEN LEVEE FAILURE CONDITION 2.4-22 CRITICAL PMH PATHS 2.4-23 OPEN COAST SURGE HYDROGRAPH MOUTH OF MISSISSIPPI RIVER 2.4-24 EFFECT OF PMH SURGE ON RIVER STAGE PROFILE 2.4-25 OPEN COAST SURGE MAXIMUM FLOOD LEVELS 2.4-26 FLOW DURATION CURVE AT SITE 2.4-27 PEAK CONCENTRATION VS. DOWNSTREAM DISTANCE 2.4-28 LOCATION MAP OF GROUNDWATER REGION, SITE AREA, AND SITE 2.4-29 POINT BAR DEPOSITS OF MISSISSIPPI RIVER 2.4-30 CONFIGURATION OF THE TOP OF THE GRAMERCY AQUIFER 2.4-31 CONFIGURATION OF THE TOP OF THE NORCO AQUIFER 2.4-32 CONFIGURATION OF THE TOP OF THE GONZALES - NEW ORLEANS AQUIFER 2.4-33 GENERALIZED CROSS-SECTION THROUGH WATERFORD SITE

WSES-FSAR-UNIT-3 2-xxv Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.4-34 CONFIGURATION OF THE POTENTIOMETRIC SURFACE IN THE GRAMERCY AQUIFER, FALL 1960 2.4-35 CONFIGURATION OF THE POTENTIOMETRIC SURFACE IN THE NORCO AQUIFER, FALL 1965 2.4-36 WATER LEVEL AND PUMPAGE NORCO AQUIFER AT NORCO 2.4-37 CONFIGURATION OF THE POTENTIOMETRIC SURFACE IN THE GONZALES-NEW ORLEANS AQUIFER, FALL 1965 2.4-38 WATER LEVELS IN GONZALES - NEW ORLEANS AQUIFER 2.4-39 WATER WELLS AND TEST HOLES IN SITE AREA 2.4-40 AREA OF DETAILED WELL SURVEY 2.4-41 AVERAGE MONTHLY GROUND WATER REQUIREMENTS FOR ST. JAMES, ST. CHARLES AND ST. JOHN THE BAPTIST PARISHES; 1970 - 2020 2.4-42 PIEZOMETRIC SURFACE IN E1 - 77 FT. SAND 2.4-43 ASSUMED PIEZOMETRIC SURFACE IN RECENT MATERIAL 2.5-1 SITE LOCATION MAP 2.5-2 REGIONAL PHYSIOGRAPHIC MAP (LAND) 2.5-3 REGIONAL PHYSIOGRAPHIC (SUBMARINE) 2.5-4 DELTAS OF THE MISSISSIPPI RIVER 2.5-5 GENERALIZED REGIONAL CROSS SECTIONS 2.5-6 REGIONAL STRATIGRAPHIC COLUMN 2.5-7 REGIONAL SURFICIAL GEOLOGY MAP GULF COASTAL PLAIN 2.5-8 SALT BASIN LOCATIONS (GENERALIZED) 2.5-9 GENERALIZED REGIONAL GROSS-SECTIONS 2.5-10 REGIONAL STRUCTURE MAP 2.5-11 REGIONAL BOUGUER GRAVITY ANOMALY MAP 2.5-12 VACHERIE FISSURE

WSES-FSAR-UNIT-3 2-xxvi Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5-13 FISK'S FEATURES OF THE DELTAIC PLAIN 2.5-14 WATERFORD SITE BOUNDARIES 2.5-15 TOPOGRAPHIC MAP OF SITE AND VICINITY 2.5-16 SURFACE GEOLOGY IN THE SITE AREA 2.5-17 EXAMPLE PETROLEUM TEST WELL ELECTRIC LOG SHOWING SITE AREA STRATIGRAPHY AND MARKER HORIZONS 2.5-18 OIL AND GAS TEST WELLS USED IN SITE STRUCTURE STUDY 2.5-19 FAULT SURFACES IN THE SITE AREA 2.5-20 SITE STRUCTURE - HORIZON 1 FROM ELECTRIC LOG SIGNATURE 2.5-21 SITE STRUCTURE - HORIZON 2 FROM ELECTRIC LOG SIGNATURE 2.5-22 SITE STRUCTURE - HORIZON 3 FROM ELECTRIC LOG SIGNATURE (LOWEST DATUM WITHOUT FAULTING) 2.5-23 SITE STRUCTURE - HORIZON 4 FROM ELECTRIC LOG SIGNATURE (HIGHEST DATUM WHICH REFLECTS FAULTING PATTERN) 2.5-24 SITE STRUCTURE - HORIZON 5 FROM ELECTRIC LOG SIGNATURE (RIDGEFIELD SAND) 2.5-25 SITE STRUCTURAL CROSS SECTION A 2.5-26 SITE STRUCTURAL CROSS SECTION B 2.5-27 SITE STRUCTURAL CROSS SECTION C 2.5-27a SITE STRUCTURAL CROSS-SECTION D 2.5-27b SITE STRUCTURAL CROSS-SECTION E 2.5-28 GEOLOGIC SECTION X-X' 2.5-29 GEOLOGIC SECTION Y-Y' 2.5-30 GEOLOGIC MAP OF WATERFORD 3 EXCAVATION 2.5-30a TOP OF PLEISTOCENE CONTOUR MAP 2.5-30b TOP OF PLEISTOCENE STUDY SECTION 1-1

WSES-FSAR-UNIT-3 2-xxvii Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5-30c TOP OF PLEISTOCENE STUDY SECTION 2-2 2.5-30d TOP OF PLEISTOCENE STUDY SECTION 3-3 2.5-30e TOP OF PLEISTOCENE STUDY SECTION 4-4 2.5-30f LOCATION MAP FOR CROSS-SECTION 5-5 2.5-30g CROSS-SECTION 5-5 2.5-31 TONAL ANOMALIES & LINEAR TRENDS IN THE SITE AREA 2.5-31a ELEVATION OF TOP OF PLEISTOCENE DEPOSITS 2.5-32 FIGURE NUMBER NOT USED (DRN 01-360) 2.5-32a ELECTRIC LOG BORING TEST NO. B-3*

2.5-32b ELECTRIC LOG COMPANY BORE TEST NO. B-5*

2.5-32c ELECTRIC LOG COMPANY NO. B-7*

2.5-32d ELECTRIC LOG BORING COMPANY NO. 41*

2.5-32e ELECTRICAL LOG BORING NO. 42*

2.5-32f ELECTRICAL LOG BORING NO. 26*

(DRN 01-360) 2.5-33 SITE BORING PLAN 2.5-34 TIME - DISTANCE PLOT FOR FIGURE 27 SEISMIC TRAVERSE A-A' 2.5-35 SEISMIC TRAVERSE A-A' 2.5-36 SEISMIC TRAVERSE B-B' 2.5-37 SEISMIC TRAVERSE C-C' 2.5-38 SEISMIC TRAVERSE D-D' (DRN 01-360)

Figures 2.5-32(a) through 2.5-32(f) are classified as historical pursuant to Waterford 3 Site Procedure W4.504 and Nuclear Energy Institute (NEI) 98-03. The figures have been physically removed from the UFSAR. However, the figures are incorporated by reference, and thus they continue to be a part of the UFSAR. These figures are available for references and use in Document Control, and they may be found as record ER-W3-01-0268-00-00 / DRN 01-360.

(DRN 01-360)

WSES-FSAR-UNIT-3 2-xxviii Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5-39 OIL & GAS PRODUCTION IN THE SITE AREA 2.5-40 CHANGE IN BENCHMARK ELEVATIONS 1938-1964 2.5-41 BENCHMARK LOCATION MAP SHOWING OIL AND GAS PRODUCTION NEAR MISSISSIPPI RIVER 2.5-42 HISTORIC EARTHQUAKE EPICENTERS WITH PROVINCES OF UNIQUE CRUSTAL PATTERNS, GEOLOGIC HISTORY AND EARTHQUAKE HISTORY 2.5-42a SEISMIC REFLECTION COVERAGE MAP 2.5-43 USC & GS ISOSEISMAL MAP OF DONALDSONVILLE EARTHQUAKE -

OCTOBER 19, 1930 2.5-44 WATERFORD SITE INTENSITY ACCELERATION RELATIONSHIP 2.5-45 SYNTHETIC EARTHQUAKE TIME - HISTORY 2.5-46 VACHERIE FISSURE DISPLACEMENT ACROSS FURROW 2.5-47 VACHERIE FISSURE SHAPE OF FISSURE 2.5-48 BORING PLOT PLAN 2.5-49 BORING PROFILE A-A' 2.5-50 BORING PROFILE B-B' & C-C' 2.5-51 BORING PROFILE D-D' 2.5-52 BORING PROFILE E-E' & F-F' 2.5-53 GRAIN SIZE DISTRIBUTION

SUMMARY

CURVE GRADE TO -40 FT. MSL 2.5-54 GRAIN SIZE DISTRIBUTION

SUMMARY

CURVE -40 FT. MSL TO -77 FT. MSL 2.5-55 GRAIN SIZE DISTRIBUTION

SUMMARY

CURVE -77 FT. MSL TO -92 FT. MSL 2.5-56 GRAIN SIZE DISTRIBUTION

SUMMARY

CURVE -92 FT. MSL TO -108 FT. MSL 2.5-57 GRAIN SIZE DISTRIBUTION

SUMMARY

CURVE -108 FT. MSL TO -116 FT. MSL 2.5-58 GRAIN SIZE DISTRIBUTION

SUMMARY

CURVE -127 FT. MSL TO -317 FT. MSL 2.5-59 GRAIN SIZE DISTRIBUTION

SUMMARY

CURVE -317 FT. MSL TO -500 FT. MSL

WSES-FSAR-UNIT-3 2-xxix Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5-60 LIQUID LIMIT VS. PLASTICITY INDEX GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5-61 LIQUID LIMIT VS. PLASTICITY INDEX -40 FT. MSL TO -77 FT. MSL 2.5-62 LIQUID LIMIT VS. PLASTICITY INDEX -92 FT. MSL TO -108 FT. MSL 2.5-63 LIQUID LIMIT VS. PLASTICITY INDEX - 108 FT. MSL TO -116 FT. MSL 2.5-64 LIQUID LIMIT VS. PLASTICITY INDEX -116 FT. MSL TO -127 FT. MSL 2.5-65 LIQUID LIMIT VS. PLASTICITY INDEX -127 FT. MSL TO -317 FT. MSL 2.5-66 UNCONFINED COMPRESSIVE STRENGTH AND COHESION VS. DEPTH 2.5-67 UNCONSOLIDATED UNDRAINED SHEAR STRENGTH GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5-68 UNCONSOLIDATED UNDRAINED SHEAR STRENGTH -40 FT. MSL TO -77 FT. MSL 2.5-69 UNCONSOLIDATED UNDRAINED SHEAR STRENGTH -127 FT MSL TO -317 FT MSL 2.5-70 CONSOLIDATED UNDRAINED SHEAR STRENGTH GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5-71 CONSOLIDATED UNDRAINED SHEAR STRENGTH -108 FT. MSL TO -116 FT. MSL 2.5-72 DRAINED SHEAR STRENGTH GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5-73 DRAINED SHEAR STRENGTH -77 FT. MSL TO -92 FT. MSL 2.5-74 DRAINED SHEAR STRENGTH - PLEISTOCENE CLAYS 2.5-75 OVERCONSOLIDATION RATIO VS. DEPTH 2.5-76 SEISMIC WAVE VELOCITY & SHEAR MODULUS VS. DEPTH 2.5-77 SHEAR MODULUS & DAMPING VS. STRAIN-RECENT MATERIAL (GRADE TO -40 FT. MSL) 2.5-78 SHEAR MODULUS & DAMPING VS. STRAIN-UPPER PLEISTOCENE (-40 FT.

MSL TO -317 FT. MSL) 2.5-79 SHEAR MODULUS & DAMPING VS. STRAIN-LOWER PLEISTOCENE (BELOW -317 FT. MSL)

WSES-FSAR-UNIT-3 2-xxx Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5-80 GENERALIZED SITE CROSS SECTION 2.5-81 EXCAVATION PLAN 2.5-82 EXCAVATIONS SECTIONS 2.5-83 DEWATERING SYSTEM PLAN 2.5-84 COMPACTED BACKFILL - STATISTICAL STUDY 2.5-85 COMPACTED BACKFILL - DRY DENSITY VS. RELATIVE DENSITY 2.5-86 COMPACTED BACKFILL - COMPACTION CURVE & GRAIN SIZE DISTRIBUTION CURVE 2.5-87 COMPACTED BACKFILL - EARTH PRESSURE COEFFICIENT VS. RADIAL STRAIN 2.5-88 COMPACTED BACKFILL - ACTIVE - PASSIVE MOHR'S CIRCLE PLOTS 2.5-89 SHEAR MODULUS & DAMPING VS. STRAIN-COMPACTED BACKFILL 2.5-90 CYCLIC SHEAR STRENGTH - COMPACTED BACKFILL 2.5-91 RESPONSE ANALYSIS MODEL 2.5-92 SHEAR STRESS AND ACCELERATION VS. DEPTH 2.5-93 FIGURE NUMBER NOT USED 2.5-93a GRAIN SIZE ANALYSES OF -55 FT. MSL MATERIALS 2.5-93b GRAIN SIZE ANALYSES OF -55 FT. MSL MATERIALS 2.5-93c GRAIN SIZE ANALYSES OF -55 FT. MSL MATERIALS 2.5-93d GRAIN SIZE ANALYSES OF -55 FT. MSL MATERIALS 2.5-93e GRAIN SIZE ANALYSES OF -55 FT. MSL MATERIALS 2.5-93f GRAIN SIZE ANALYSES OF -55 FT. MSL MATERIALS 2.5-94 COMPACTION CURVES FOR -55 FT. MSL MATERIALS 2.5-95 FIGURE NUMBER NOT USED 2.5-95a GRAIN SIZE ANALYSES OF -77 FT. MSL MATERIALS

WSES-FSAR-UNIT-3 2-xxxi Revision 14 (12/05)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5-95b GRAIN SIZE ANALYSES OF -77 FT. MSL MATERIALS 2.5-95c GRAIN SIZE ANALYSES OF -77 FT. MSL MATERIALS 2.5-96 CYCLIC SHEAR STRENGTH - IN SITU MATERIAL 2.5-97 LIQUEFACTION POTENTIAL FACTOR OF SAFETY PLOT 2.5-98 GRAIN SIZE AND VOID RATIO COMPARISONS WITH LEE AND FITTON 2.5-99 CYCLIC TEST COMPARISONS WITH LEE AND FITTON 2.5-100 STATIC PRESSURE DIAGRAM 2.5-101 DYNAMIC EARTH PRESSURE DIAGRAM 2.5-102 DESIGN CONCEPT OUTLINE 2.5-103 BEARING PRESSURE HISTORY AT -47 FT. MSL 2.5-104 CONSTRUCTION DIAGRAM - STAGE 1 2.5-105 CONSTRUCTION DIAGRAM - STAGE 2 2.5-106 CONSTRUCTION DIAGRAM - STAGE 3 2.5-107 CONSTRUCTION DIAGRAM - STAGE 4 2.5-108 CONSTRUCTION DIAGRAM - STAGE 5 2.5-109 CONSTRUCTION DIAGRAM - STAGE 6 2.5-110 CONSTRUCTION DIAGRAM - STAGE 7 2.5-111 CONSTRUCTION DIAGRAM - STAGE 8 2.5-112 INSTRUMENTATION PLOT PLAN 2.5-112a SETTLEMENT MONITORING POINTS (1981-84) 2.5-112b PRIMARY SETTLEMENT MONITORING POINT LOCATIONS (1985-1986) 2.5-112c SECONDARY SETTLEMENT MONITORING POINT LOCATIONS (1985-1986) 2.5-112d SETTLEMENT MONITORING POINT LOCATIONS 2.5-113 PIEZOMETER, HEAVE POINT AND EXTENSOMETER RESPONSES SHEET 1 OF 5

WSES-FSAR-UNIT-3 2-xxxii Revision 11 (05/01)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5-113 PIEZOMETER, HEAVE POINT AND EXTENSOMETER RESPONSES SHEET 2 OF 5 2.5-113 PIEZOMETER, HEAVE POINT AND EXTENSOMETER RESPONSES SHEET 3 OF 5 2.5-113 PIEZOMETER, HEAVE POINT AND EXTENSOMETER RESPONSES SHEET 4 OF 5 2.5-113 PIEZOMETER, HEAVE POINT AND EXTENSOMETER RESPONSES SHEET 5 OF 5 2.5-114 INCLINOMETER MOVEMENT NORTH-SOUTH DIRECTION 2.5-115 INCLINOMETER MOVEMENT EAST-WEST DIRECTION 2.5-116 SITE AREA SETTLEMENT SHEET 1 OF 2 2.5-116 SITE AREA SETTLEMENT SHEET 2 OF 2 2.5-117 COMPOSITE FOUNDATION MAT SETTLEMENT (SHEET 1 OF 3) 2.5-117 COMPOSITE FOUNDATION MAT SETTLEMENT (SHEET 2 OF 3) 2.5-117 COMPOSITE FOUNDATION MAT SETTLEMENT (SHEET 3 OF 3) 2.5-118 COMPOSITE FOUNDATION MAT DIFFERENTIAL SETTLEMENT CONTOURS 2.5A-1 GRAIN SIZE ANALYSES 2.5A-2 GRAIN SIZE ANALYSES 2.5A-3 GRAIN SIZE ANALYSES 2.5A-4 GRAIN SIZE ANALYSES 2.5A-5 GRAIN SIZE ANALYSES 2.5A-6 GRAIN SIZE ANALYSES 2.5A-7 GRAIN SIZE ANALYSES 2.5A-8 GRAIN SIZE ANALYSES 2.5A-9 GRAIN SIZE ANALYSES 2.5A-10 GRAIN SIZE ANALYSES 2.5A-11 GRAIN SIZE ANALYSES 2.5A-12 GRAIN SIZE ANALYSES

WSES-FSAR-UNIT-3 2-xxxiii Revision 11 (05/01)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-13 GRAIN SIZE ANALYSES 2.5A-14 GRAIN SIZE ANALYSES 2.5A-15 GRAIN SIZE ANALYSES 2.5A-16 GRAIN SIZE ANALYSES 2.5A-17 GRAIN SIZE ANALYSES 2.5A-18 GRAIN SIZE ANALYSES 2.5A-19 GRAIN SIZE ANALYSES 2.5A-20 GRAIN SIZE ANALYSES 2.5A-21 GRAIN SIZE ANALYSES 2.5A-22 GRAIN SIZE ANALYSES 2.5A-23 GRAIN SIZE ANALYSES 2.5A-24 GRAIN SIZE ANALYSES 2.5A-25 GRAIN SIZE ANALYSES 2.5A-26 GRAIN SIZE ANALYSES 2.5A-27 GRAIN SIZE ANALYSES 2.5A-28 GRAIN SIZE ANALYSES 2.5A-29 GRAIN SIZE ANALYSES 2.5A-30 GRAIN SIZE ANALYSES 2.5A-31 GRAIN SIZE ANALYSES 2.5A-32 GRAIN SIZE ANALYSES 2.5A-33 GRAIN SIZE ANALYSES 2.5A-34 GRAIN SIZE ANALYSES 2.5A-35 GRAIN SIZE ANALYSES 2.5A-36 GRAIN SIZE ANALYSES

WSES-FSAR-UNIT-3 2-xxxiv Revision 11 (05/01)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-37 GRAIN SIZE ANALYSES 2.5A-38 GRAIN SIZE ANALYSES 2.5A-39 GRAIN SIZE ANALYSES 2.5A-40 GRAIN SIZE ANALYSES 2.5A-41 GRAIN SIZE ANALYSES 2.5A-42 GRAIN SIZE ANALYSES 2.5A-43 GRAIN SIZE ANALYSES 2.5A-44 GRAIN SIZE ANALYSES 2.5A-45 GRAIN SIZE ANALYSES 2.5A-46 GRAIN SIZE ANALYSES 2.5A-47 GRAIN SIZE ANALYSES 2.5A-48 GRAIN SIZE ANALYSES 2.5A-49 GRAIN SIZE ANALYSES 2.5A-50 GRAIN SIZE ANALYSES 2.5A-51 GRAIN SIZE ANALYSES 2.5A-52 GRAIN SIZE ANALYSES 2.5A-53 GRAIN SIZE ANALYSES 2.5A-54 GRAIN SIZE ANALYSES 2.5A-55 GRAIN SIZE ANALYSES 2.5A-56 GRAIN SIZE ANALYSES 2.5A-57 GRAIN SIZE ANALYSES 2.5A-58 GRAIN SIZE ANALYSES 2.5A-59 GRAIN SIZE ANALYSES 2.5A-60 GRAIN SIZE ANALYSES

WSES-FSAR-UNIT-3 2-xxxv Revision 11 (05/01)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-61 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-62 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-63 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-64 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-65 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-66 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-67 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-68 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-69 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-70 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-71 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-72 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-73 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-74 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-75 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-76 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-77 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-78 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-79 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-80 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-81 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-82 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-83 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-84 UNCONSOLIDATED UNDRAINED STRENGTH TESTS

WSES-FSAR-UNIT-3 2-xxxvi Revision 11 (05/01)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-85 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-86 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-87 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-88 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-89 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-90 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-91 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-92 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-93 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-94 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-95 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-96 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-97 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-98 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-99 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-100 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-101 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-102 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-103 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-104 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-105 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-106 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-107 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-108 UNCONSOLIDATED UNDRAINED STRENGTH TESTS

WSES-FSAR-UNIT-3 2-xxxvii Revision 11 (05/01)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-109 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-110 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-111 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-112 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-113 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-114 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-115 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-116 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-117 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-118 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-119 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-120 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-121 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-122 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-123 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-124 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-125 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-126 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-127 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-128 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-129 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-130 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-131 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-132 UNCONSOLIDATED UNDRAINED STRENGTH TESTS

WSES-FSAR-UNIT-3 2-xxxviii Revision 12-C (07/03)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-133 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-134 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-135 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-136 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-137 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-138 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-139 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-140 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-141 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-142 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-143 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-144 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-145 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-146 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-147 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-148 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-149 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-150 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-151 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-152 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-153 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-154 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-155 UNCONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-156 UNCONSOLIDATED UNDRAINED STRENGTH TESTS

WSES-FSAR-UNIT-3 2-xxxix Revision 12-C (07/03)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-157 CONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-158 CONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-159 CONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-160 CONSOLIDATED UNDRAINED STRENGTH TESTS 2.5A-161 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-162 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-163 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-164 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-165 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-166 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-167 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-168 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-169 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-170 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-171 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-172 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-173 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-174 CONSOLIDATION TESTS GRADE TO -40 FT. MSL (RECENT MATERIAL) 2.5A-175 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-176 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-177 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-178 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-179 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-180 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL

WSES-FSAR-UNIT-3 2-xl Revision 12-C (07/03)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-181 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-182 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-183 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-184 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-185 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-186 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-187 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-188 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-189 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-190 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-191 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-192 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-193 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-194 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-195 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-196 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-197 CONSOLIDATION TESTS -40 FT. MSL TO -77 FT. MSL 2.5A-198 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-199 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-200 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-201 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-202 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-203 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-204 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL

WSES-FSAR-UNIT-3 2-xli Revision 12-C (07/03)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-205 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-206 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-207 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-208 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-209 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-210 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-211 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-212 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-213 CONSOLIDATION TESTS -92 FT. MSL TO -108 FT. MSL 2.5A-214 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-215 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-216 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-217 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-218 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-219 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-220 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-221 CONSOLIDATION TESTS -108 FT. MSL TO -116 FT. MSL 2.5A-222 CONSOLIDATION TESTS -116 FT. MSL TO -127 FT. MSL 2.5A-223 CONSOLIDATION TESTS -116 FT. MSL TO -127 FT. MSL 2.5A-224 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-225 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-226 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-227 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-228 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL

WSES-FSAR-UNIT-3 2-xlii Revision 12-C (07/03)

CHAPTER 2 LIST OF FIGURES (Cont'd)

Figure Title 2.5A-229 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-230 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-231 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-232 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-233 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-234 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-235 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-236 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-237 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-238 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-239 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-240 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-241 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-242 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-243 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-244 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-245 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-246 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL 2.5A-247 CONSOLIDATION TESTS -127 FT. MSL TO -317 FT. MSL

WSES-FSAR-UNIT-3 2-xliii Revision 15 (03/07)

UPDATE REFERENCE LIST Chapter 2 Section Cross References Revision 12-C Table 2.2-4 Sheet 2 ER-W3-2000-0948-000/DRN 02-1834 Table 2.2-4 Sheet 3 Table 2.2-4 Sheet 4 Table 2.2-4 Sheet 6 Table 2.2-4 Sheet 7 Table 2.2-4 Sheet 8 Table 2.2-4 Sheet 10 Table 2.2-4 Sheet 11 Table 2.2-4A Table 2.2-4B Table 2.2-3d (all 16 sheets)

Table 2.2-5 (both pages)

Revision 14 Table Of Contents ER-W3-2001-1149-000/DRN 03-2055 Section 2.1.1.3 Section 2.1.3.4.1 Section 2.2.3 Section 2.2.3.1 Section 2.2.3.1.4 Section 2.3.4 Section 2.4.3 References 2.3 Table 2.3-136 Figure 2.3-48 Section 2.2.3 ER-W3-2004-0276-000/DRN 05-149 Section 2.2.3.1.4 Section 2.2.3.2 Section 2.2.3.3.6 Section 2.2.3.3.6 ER-W3-2004-0276-002/DRN 05-845 Revision 15 Section 2.1.1.3 ER-W3-2006-0210-000/DRN 06-624 Section 2.2.3.1.3.2 ER-W3-2006-0281-000/DRN 06-869 Section 2.3.5.1 Section 2.4.3.7 Section 2.5.4.13.4 ER-W3-2006-0223-000/DRN 06-877 Section 2.2.3.1.3.1 ER-W3-2006-0223-000/DRN 06-905 Section 2.2.3.1.3.2 Section 2.3.5.1 Section 2.5.4.5.3.2 Section 2.2A.1.3 ER-W3-2006-0296-000/DRN 06-926

WSES-FSAR-UNIT-3 2-xliv Revision 302 (12/08)

UPDATE REFERENCE LIST Chapter 2 Section Cross References Revision 301 Section 2.3.2.1.5 EC-1837 Section 2.3.2.2 Section 2.3.3.1.5 Section 2.3.3.1.7 Section 2.3.3.2 Section 2.3: References Section 2.4.2.3.4 EC-5000082442 EC-2097 Table of Contents EC-5000082218 Section 2.2.1 Section 2.2.2.1.2 Section 2.2.2.2 Section 2.2.2.3 Section 2.2.2.4 Section 2.2.2.6 Section 2.2.3 Section 2.2.3.1.3.1.1 Section 2.2.3.3 Section 2.2.3.3.1 Section 2.2.3.3.2 Section 2.2.3.3.4 Section 2.2.3.3.5 Section 2.2.3.3.6 Section 2.2.: References Table 2.2-3A Table 2.2-3B Sh. 1 of 8 thru Sh. 8 of 8 Table 2.2-3C Table 2.2-3D Sh. 1 of 15 thru Sh. 15 of 15 Table 2-23E Sh. 1 of 11 thru Sh. 11 of 11 Table 2.2-3F Sh 1. of 4 thru Sh. 4 of 4 Table 2.2-3G Table 2.2-4 Table 2.2-4A Table 2.2-4B Table 2.2-5 Table 2.2-6 Sh. 1 of 2 thru Sh. 2 of 2 Table 2.2-7 Figure 2.2-1 Figure 2.2-2 Figure 2.2-3 Figure 2.2-3a Figure 2.2-3b Figure 2.2-3c Figure 2.2-3d Figure 2.2-3e Revision 302 Section 2.4.2.2 LBDCR 2008-001

WSES-FSAR-UNIT-3 2-xlv Revision 307 (07/13)

Section Cross References Revision 303 Section 2.4.11.5 EC-530 Section 2.4.11.6 Section 2.3.3.1.2 EC-8688 Revision 305 Section 2.4.1.1 EC-29230 Section 2.4.3.7 EC-30923 Revision 306 Section 2.4.3.5.3 EC-32952 Revision 307 Table of Contents EC-38835 Table of Contents EC-39014 Section 2.2.1 Section 2.2.2.2 Section 2.2.2.3 Section 2.2.3.1.3.1.1 Section 2.2.3.1.3.2 Section 2.2: REFERENCES Table 2.2-3A Table 2.2-3B Table 2.2-3D Table 2.2-3E Table 2.2-3F Table 2.2-3G Table 2.2-5 Table 2.2-6 Figure 2.2-1 Figure 2.2-3a Figure 2.2-3b Figure 2.2-3c Figure 2.2-3d Figure 2.2-3e Figure 2.2-3f Figure 2.2-3g Section 2.2.3.1 EC-40308 Section 2.2.3.3.5 EC-41671 Section 2.2.3.3.6 Table 2.2-4A Section 2.4-10 EC-42115

WSES-FSAR-UNIT-3 2-xlvi Revision 309 (06/16)

Revision 308 Section 2.1.1.1 LBDCR 14-023 Section 2.4.10 EC 45161 Revision 309 Section 2.1.3.3 LBDCR 15-005 Table 2.1-4 Table 2.1-7 Figure 2.1-4 LBDCR 15-040 Figure 2.1-4a Figure 2.1-3 Figure 2.2A-1 Figure 2.3-29 Figure 2.3-47 Figure 2.4-1 Table of Contents LBDCR 15-048 Section 2.2.1 Section 2.2.2 Section 2.2 References Table 2.2-1 Sh. 1 & 3 Table 2.2-3A Table 2.2-3B sh. 1-20 Table 2.2-3D sh. 1-14 Table 2.2-3E sh. 1-3 Table 2.2-3F sh. 1-4 Table 2.2-3G Table 2.2-5 Sh. 1-2 Table 2.2-6 Sh. 1-4 Figure 2.2-1 Figure 2.2-3a Figure 2.2-3d Figure 2.2-3f Section 2.4.1.1 LBDCR 15-026 Section 2.4.2.1 Section 2.4.2.2 Section 2.4.3.1 Section 2.4.3.5 Section 2.4.3.5.3 Section 2.4.3.7 Section 2.4.3.8 Section 2.4.4 Section 2.4.5.1 Section 2.4.5.2 Section 2.4.5.3 Section 2.4.7 Section 2.4.9 Section 2.4.10 Section 2.4.11.5 Section 2.4.12 Section 2.4.13.1.2 Section 2.4.13.1.3 Section 2.4.13.2.1 Section 2.4.13.2.3 Section 2.4.13.3