WSES-FSAR-UNIT-3 1.7-1 Revision 13-B (01/05)

(DRN 04-1444, R13-B)

The following information is historical pursuant to NEI 98-03 and is identified by a designation of start and end.

Start of historical data.

(DRN 04-1444, R13-B) 1.7 ELECTRICAL, INSTRUMENTATION, AND CONTROL DRAWINGS Table 1.7-1 is a list of proprietary and nonproprietary electrical, instrumentation and control (EI&C) drawings. Three copies of all proprietary and seven copies of all nonproprietary drawings have been submitted under separate cover.

Drawing 1564-B-431 (Sheet 1 thru 11) listed in Table 1.7-1 provides symbols for flow diagrams and instrument schematics and logic diagrams.

(DRN 04-1444, R13-B)

End of historical data.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

The following table is historical pursuant to NEI 98-03 and is identified by a designation of start and end.

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 1 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (A) Instrument Location Arrangement Drawings G-428 1

7 11-81 E

Turbine Building 2

6 12-80 E

Turbine Building 3

6 10-80 E

Reactor Building 4

5 10-80 E

Reactor Building 5

6 12-80 E

Reactor Building 6

5 10-80 E

Reactor Building 7

6 10-80 E

Reactor Building 8

7 01-82 E

Reactor Building 9

5 01-82 E

Reactor Building 10 5

11-81 E

Reactor Building G-429 1

5 01-82 E

Miscellaneous Area 2

1 12-80 E

Miscellaneous Area 3

2 12-80 E

Miscellaneous Area G-432 1

7 11-81 E

Reactor Auxiliary Building 2

5 12-80 E

Reactor Auxiliary Building 3

6 05-81 E

Reactor Auxiliary Building 4

5 12-80 E

Reactor Auxiliary Building 5

6 12-80 E

Reactor Auxiliary Building 6

6 07-78 E

Reactor Auxiliary Building 7

6 01-82 E

Reactor Auxiliary Building 8

7 01-82 E

Reactor Auxiliary Building C-433 5

06-78 E

Fuel Handling Building G-435 1

2 08-78 E

No Sampling System Instr. Arrgt. (Turbine Building) 2 2

11-78 E

No Sampling System Instr. Arrgt. (Reactor Aux. Building) 3 2

6-23-78 E

Sampling System (Reactor Aux. Bldg.)

4 2

7-21-78 E

Sampling System (Reactor Bldg.)

5 2

7-21-78 E

Sampling System (Reactor Bldg.)

LEGEND:

E - EBASCO CE - COMBUSTION ENGINEERING

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 2 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (A) Instrument Location Arrangement Drawings (Cont'd)

LOU-5817)

G-391) Dwg's for HVAC System 70% @ 9/77 1

3 11-81 E

Turbine Building, HWAC System, Instrumentation 2

2 12-80 E

No Turbine Building, HVAC System Instrumentation 3

3 08-81 E

No Reactor & Fuel Handling Bldg, HVAC Instrumentation 4

4 01-82 E

No Reactor Auxiliary Building, HVAC Instrumentation 5

4 11-81 E

No Reactor Auxiliary Building, HVAC Instrumentation 6

3 11-80 E

No Reactor Auxiliary Building, HVAC Instrumentation 7

3 11-81 E

No HVAC Instrumentation Location Arrangement (B) Instrument Schematics and Logic Diagrams - Safety Related B-431 Cover 0

3-8-73 E

No Instrument Schematics and Logic Diagrams A

1 1-18-80 E

No Organization of Drawing B

6 4-7-80 E

No Index c

6 4-7-80 E

No Index D

4 4-7-80 E

No Index E

6 4-7-80 E

No Index F

1 4-7-80 E

No Index 0.1 0

9-30-71 E

No Pipe, Valves & Instrument Symbols (Cover Sheet) 0.2 4

12-19-79 E

No Instrumentation - Symbols 0.3 3

7-23-79 E

No Instrumentation - Functions & Meanings or Identification Letters 0.4 3

12-19-79 E

No Line Designations 0.5 3

1-18-80 E

No Line System Description and Symbols (Abbreviations) 0.6 4

1-18-80 E

No Abbreviations (Continued) 0.7 4

1-23-80 E

No Valves Symbols 0.8 3

12-19-79 E

No Valves Symbols 0.9 1

12-19-79 E

No Pipe or Equipment Accessories Symbols 0.10 2

12-19-79 E

No Equipment Symbols 0.11 1

12-19-79 E

No Graphical Symbols for Logic Diagrams 3AS 4

12-19-79 E

No Contaiment Spray 4AS 4

12-19-79 E

No Containment Spray 5AS 3

12-19-79 E

No Contaiment Sump Instruments & Leak Detection 65 3

12-19-79 E

No Containment Pressure 145 2

12-19-79 E

No Main Steam Isolation Valve Steam Generator - 1 155 2

12-19-79 E

No Main Steam Isolation Valve Steam Generator - 2 35ASI 1

12-19-79 E

No Emergency Steam Generator Feedwater System 35AS2 2

6-11-80 E

No Emergency Steam Generator Feedwater System 95AS 3

12-19-79 E

No Condensate Storage Pool Instrumentation

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 3 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (B) Instrument Schematics and Logic Diagrams - Safety Related 114AS 2

6-19-78 E

No Shutdown Heat Exchangers 115AS 2

6-19-78 E

No Component Cooling Water Supply to & Return from containment 118AIS 3

12-19-79 E

No Containment Fan Cooler Unit System Instrumentation 118A2S 3

12-19-79 E

No Containment Fan Cooler Unit System Instrumentation 120AS 2

6-11-80 E

No Component Cooling Water Pump Schematic 121AS 3

11-6-80 E

No Component Cooling Water Surge Tank & Return Headers 122AS 3

6-11-80 E

No Component Cooling Water System A (Redrawn) 123AS 3

6-11-80 E

No Component Cooling Water System B (Redrawn)

B-431 124AS 3

6-11-80 E

No Component Cooling Water Header Instrumentation 125AS 3

6-11-80 E

No Component Cooling Water to Control Room Chillers 126AS 1

6-19-78 E

No Component Cooling Water to Diesel Gen Heat Exchangers 153S 1

12-19-79 E

No Diesel Oil System Inst. (Diesel Oil Feed Tank "A")

154S 1

12-19-79 E

No Diesel Oil System Inst. (Diesel Oil Feed Tank "B")

220S 0

8-29-78 E

No Miscellaneous Instrumentation 221S 1

8-29-78 E

No RAB-CCW Pump Room "A", Air Handling Unit AH-10 (3A-SA) Instrumentation 222S 1

8-29-78 E

No RAB-CCW Pump Room "B", Air Handling Unit AH-10 (3B-SB) Instrumentation 223S 1

8-29-78 E

No RAB-Emerg. FW Pump "A" Room "A", Air Handling Unit AH-17 (3A-SA) Instrumentation 224S 1

8-29-78 E

No RAB-Emerg. FW Pump "B" Room "B", Air Handling Unit AH-17 (3B-SB) Instrumentation 225S 1

8-29-78 E

No RAB-Charging Pump "A" Room "A", Air Handling Unit AH-18 (3A-SA) Instrumentation 226S 1

8-29-78 E

No RAB-Charging Pump "B" Room "B", Air Handling Unit AH-18 (3B-SB) Instrumentation 229S 2

2-12-79 E

No RAB-Shutdown Ht. Exch. "B" Room "B", Air Handling Unit AH-3 (3B-SB) Instrumentation 230S 1

8-29-78 E

No RAB-Sbuidown Ht. Exch "A" Room "A", Air Handling Unit AH-3 (3A-SA) Instrumentation 231S 1

8-29-78 E

No RAB-CCW Pump Ht. Exch. "B" Room "B", Air Handling Unit AH-24 (3B-SB) Instrumentation 232S 1

8-29-78 E

No RAB-CCW Pump Ht. Exch. "A" Room "A", Air Handling Unit AH-24 (3A-SA) Instrumentation 233S 2

2-12-79 E

No RAB-Safeguard Pumps Room "A", Air Handling Unit AH-2 (3A-SA) Instrumentation 234S 2

2-12-79 E

No RAB-Safeguard Pumps Room "A", Air Handling Unit AH-2 (3C-SA) Instrumentation

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 4 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (B) Instrument Schematics and Logic Diagrams - Safety Related B-431 235S 2

2-12-79 E

No RAB-Safeguard Pumps Room "B", Air Handling Unit AH-2 (3B-SB) Instrumentation 236S 2

2-12-79 E

No RAB-Safeguard Pumps Room "B", Air Handling Unit AH-2 (3D-SB) Instrumentation 237S 2

2-12-79 E

No RAB-Safeguard Pump Room "A", Air Handling Unit AH-21 (3-SAB) instrumentation 238S 1

8-29-78 E

No RAB-Control Room Equipment Room, Air Handling Unit AH-26 (3A-SA) Instrumentation 239S 1

8-29-78 E

No RAB-Control Room Equipment Room, Air Handling Unit AH-26 (3B-SH) Instrumentation 240S 1

8-29-78 E

No RAB-CCW Pump Room "A/B", Air Handling Unit AH-20 (3B-SAB) Instrumentation 241S 1

8-29-78 E

No RAB-CCW Pump Room "A/B", Air Handling Unit AH-20 (3A-SAB) Instrumentation 242S 1

8-29-78 E

No RAB-Charging Pump Room "A/B", Air Handling Unit AH-22 (3A-SAB) Instrumentation 243S 1

8-29-78 E

No RAB-Charging Pump Room "A/B", Air Handling Unit AH-22 (3B-SAB) Instrumentation 245S 2

12-14-79 E

No Control Atmos Release System (CARS) Instrumentation 246S 1

8-29-78 E

No Switchgear Area Ventilation System AH-25 (3A-SA) 247S 1

8-29-78 E

No Switchgear Area Ventilation System AH-25 (3B-SB) 248S 1

8-29-78 E

No Battery Rm Exhaust Fans 251S 2

12-14-79 E

No Emerg Diesel Gen Rm "A" Vent Sys Fan E-28 (3A-SA) 252S 2

12-19-79 E

No Emerg Diesel Gen Rm "B" Vent Sys Fan E-28 (38-SB) 253S 2

12-14-79 E

No Water Chiller WC-1 (3A-SA) 254S 2

12-14-79 E

No Water Chiller WC-1 (3B-SB) 255S 2

12-14-79 E

No Water Chiller WC-1 (3C-SA/B) 256S 2

12-14-79 E

No Chiller Water Sys Isol Valves 260S 1

12-06-78 Control Room, Conference Room & Kitchen Exhaust Fan 261S 1

12-06-78 E

No Control Rm Toilet Exh Fans E-34 (3A-SA) & E-34 (3B-SB) 262S 1

12-14-79 E

No Swgr Area Vent System AH-30 (3A-SA) 263S 2

12-14-79 E

No Swgr Area Vent System AH-30 (3B-SB) 264S 3

9-18-81 E

No Cont Rm Emerg Filtration Unit S-8 (3A-SA) 265S 2

9-18-81 E

No Cont Rm Emerg Filtration Unit S-8 (3B-SB) 266S 1

12-6-78 E

No Cont Rm Air Handling Unit AH-12 (3A-SA)

(DRN 01-758, R11-A) 267S 2

12-14-79 E

No Cont Rm Air Handling Unit AH-12 (3B-SB)

(DRN 01-758, R11-A) 268S 3

9-18-81 E

No SH1eld Bldg Vent System E-17 (3A-SA)

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 5 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (B) Instrument Schematics and Logic Diagrams - Safety Related B-431 269S 3

9-18-81 E

No SH1eld Bldg Vent System E-17 (3B-SB) 270S 1

2-12-79 E

No RAB HVAC Equip Rm Vent System AH-13 (3A-SA) & E-41 (3A-SA) 271S 1

2-12-79 E

No AH-13 (3A-SA) Rm Vent System AH-13 (3B-SB) & E-41 (3B-SB) 272S 0

8-29-78 Fuel Handling Building Normal Supply Fan AH-14 (3) 274S 2

9-18-81 E

No FHB Emerg Filtration Unit E-35 (3A-SA) 275S 2

9-18-81 E

No FHB Emerg Filtration Unit E-35 (3B-SB) 276S 0

8-29-78 Fuel Handling Building Mechanical Equipment Room Exhaust Fans E-21 (3A-SA) & E-21 (3B-SB) 283S 1

9-8-81 E

No Containment Vacuum Relief 284S 0

8-29-78 E

No Containment Fan Clr AH-1 (3C-SA) & (3A-SA) 285S 0

8-29-78 E

No Containment Fan Clr AH-1 (3D-SB) & (3B-SB) 289S 0

8-29-78 E

No Battery Rooms Fan Room Fans E-52 (3A-SA) & (3B-SB) 295S 2

9-8-81 E

No Containment Purge System 296S 1

9-8-81 E

No CVAS Exhaust Fan E-23 (3A-SA) 297S 2

9-8-81 E

No CVAS Exhaust Fan E-23 (3B-SB) 298S 1

12-19-79 1

No CVAS Isolation Valves 299S 1

12-19-79 E

No CVAS Isolation Valves

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 6 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (B) Instrument Schematics and Logic Diagrams - Safety Related B-431 1

2 12-14-79 E

No Containment Spray 2A 3

12-19-79 E

No Refueling Water Storage Pool Makeup Control 11 1

12-14-79 E

No Main Steam System 12 4

12-19-79 E

No Main Steam From Steam Generator - 1 13A 4

12-19-79 E

No Main Steam From Steam Generator - 2 16A 4

12-19-79 E

No Steam to Steam Generator Feedwater Pump Turbines 17A 3

12-19-79 E

No Main Steam to H.P. Turbine 18A 2

6-19-78 E

No Steam Dump Lines 19 4

2-12-79 E

No Main Steam to Moisture Separator Reheaters 24 0

12-14-79 E

No Auxiliary Steam System 25 1

12-19-79 E

No Auxiliary Steam System 26 1

12-19-79 E

No Auxiliary Steam System 31 1

12-14-79 E

No Feedwater System 32A-1 3

3-19-80 E

No Feedwater Pump "A" Flow System 32A-2 1

12-19-79 E

No Feedwater Pump "A" Flow System 33A-1 1

3-19-80 E

No Feedwater Pump "B" Flow System 33A-2 1

12-19-79 E

No Feedwater Pump "B" Flow System 34 4

12-19-79 E

No Feedwater to H.P. Heater IA/LB/IC 46 1

12-14-79 E

No Extraction Steam System 47A 4

12-19-79 E

No Extraction Steam From H.P. Turbine to H.P. Heaters IA/IB/IC 48A 4

12-19-79 E

No Cold Rebeat Steam from H.P. Turbine to L.P. Heaters 2A/2B/2C 49 2

6-19-78 E

No Steam to L.P. Turbines A/B/C 50 3

6-19-78 E

No Condenser Vacuum 51A 4

12-19-79 E

No Extraction Steam From L.P. Turbine to I.P. Heater 3A 52A 4

12-19-79 E

No Extraction Steam From L.P. Turbine to I.P. Heater 3B 53A 4

12-19-79 E

No Extraction Steam From L.P. Turbine to I.P. Heater 3C 54A 4

12-19-79 E

No Extraction Steam From L.P. Turbine to I.P. Heater 4A 55A 4

12-19-79 E

No Extraction Steam From L.P. Turbine to I.P. Heater 4B 56A 4

12-19-79 E

No Extraction Steam from L.P. Turbine to I.P. Heater 4C 58 0

6-19-78 E

No L.P. Heaters 5 & 6 Shell Pressure 59 0

6-19-78 E

No Cold Reheat from H.P. Turbine to Moisture Separator Reheater 66 1

12-14-79 E

No Heater Drain System 67A 4

12-19-79 E

No Moisture Separator "A" Drain System Instrumentation 68A 4

12-19-79 E

No Moisture Separator "B" Drain System Instrumentation 69 3

12-19-79 E

No Heater IA/IB/IC Drain System Instrumentation 70A 5

8-10-81 E

No Heater 2A & Drain Pump System Instrumentation 71A 5

8-10-81 E

No Heater 2B & Drain Pump System Instrumentation 72A 5

8-10-81 E

No Heater 2C & Drain Pump System Instrumentation

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 7 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (B) Instrument Schematics and Logic Diagrams - Non-Safety Related B-431 73 3

12-19-79 E

No Heater 3A/3B/3C Drain System Instrumentation 74 3

12-19-79 E

No Heater 4A/4B/4C Drain System Instrumentation 75 3

12-19-79 E

No Heater SA/5B/SC Drain System Instrumentation 76 3

12-19-79 E

No Heater 6A/6B/6C Drain System Instrumentation 77 2

2-12-80 E

No M.S.R. "A" Shell Drain List 78 2

2-12-80 E

No M.S.R. "B" Shell Drain List 86 1

12-14-79 E

No Condensate System 87 4

12-19-79 E

No Condensate To and From Gland Steam Condenser 88A 4

12-19-79 E

No Condenser Hotwell Level Control 89 4

2-12-80 E

No Condensate to and from Heaters in Condenser Neck 91A 3

12-19-79 E

No Gland Seal Leakoff Tank Level Control 92 3

2-12-80 E

No Condensate to and from IP Heaters 93A 4

12-19-79 E

No Condensate Pumps 94A 3

12-19-79 E

No Primary Water & CNDS Storage Tank System 101 1

12-14-79 E

No Turbine Closed Cooling Water System 102A 3

2-12-80 E

No Surge Tank & Turbine Cooling Water Pumps Instrumentation System 103 3

2-12-80 E

No Turbine Cooling Water Heat Exchangers Instrumentation System 104 2

12-19-79 E

No Cooling Water to Turbine L.O. Coolers 105 0

6-19-78 E

No Cold Gas System Generator Cooling 106 1

12-19-79 E

No Steam Generator Feed Pump Turbine Coolers "A & B" 107 0

6-19-78 E

No Generator Stator Water Coolers 108 0

6-19-78 E

No Turbine Electro Hydraulic Fluid Cooling 111 1

12-14-79 E

No Component Closed Cooling Water System 112 3

12-19-79 E

No Cooling Water System for Pump Coolers (TYP) 113 1

6-19-78 E

No Waste and Boric Acid Concentrator 116A 3

12-19-79 E

No Reactor Coolant Pumps Coolers 117 4

12-19-79 E

No Letdown Heat Exchanger Cooling Water System 119 4

12-19-79 E

No Fuel Pool Heat Exchanger Cooling Water System 128 1

12-14-79 E

No Firewater and Domestic Water System 129A 2

7-23-79 E

No Firewater Storage System 136 1

12-14-79 E

No Lube Oil System 146 1

12-14-79 E

No Instrument and Station Air System 147 2

7-23-79 E

No Station Air System 148 2

7-23-79 E

No Instrument Air System 152 1

12-14-79 E

No Emergency Diesel Generator Oil System 156 1

12-14-79 E

No Condenser Cooling Water System 157A 2

12-19-79 E

No Circulating Water Pumps Schematic 158 1

6-19-78 E

No Cooling Water to Turbine Closed Cooling Water Heat Exchangers 159A 1

6-19-78 E

No CW Air Evacuation Pumps Schematic

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 8 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (B) Instrument Schematics and Logic Diagrams - Non-Safety Related B-431 160 1

6-19-78 E

No Cooling Water to and From Condenser "A" 161 1

6-19-78 E

No Cooling Water to and From Condenser "B" 162 1

6-19-78 E

No Cooling Water to and From Condenser "C" 163A-1 0

6-30-78 E

No Screen Wash System 163A-2 0

6-30-78 E

No Screen Wash System 171 1

12-14-79 E

No Gas System 181 1

12-14-79 E

No Blowdown System 182 0

9-19-78 E

No Steam Generator Blowdown System Inst.

183 1

12-19-79 E

No Blowdown Tank & Blowdown Pumps "A & B" 184 1

12-19-79 E

No Blowdown Heat Exchangers "A & B" 185 1

12-19-79 E

No Blowdown Demineralizer System 190 0

6-19-78 E

No Sump Pumps Level Instruments 191 1

12-14-79 E

No Sampling Systems 201 1

12-14-79 E

No Containment Air 202 2

12-19-79 E

No Containment Radiation Monitoring 211 1

12-14-79 E

No HVAC System 212 1

12-14-79 E

No Supplementary Chiller Cooling Tower and Chiller Water Control 213 1

12-14-79 E

No Supplementary Chiller Cooling Tower and Chiller Water Control 214 1

12-14-79 E

No Supplementary Chilled Water Control 215 1

12-14-79 E

No Supplementary Chilled Water Cooling Tower Makeup Control 217 1

5-05-81 E

No Condensate Pump "A" Motor Exhaust Fans E-53 (3A&3B) 218 0

8-29-78 E

No Condensate Pump "B" Motor Exhaust Fans E-54 (3&3B) 219 0

8-29-78 E

No Condensate Pump "C" Motor Exhause Fans E-55 (3A&3B) 227 1

8-29-78 E

No RAB Blowdown Filter "B" Room "B" Air Handling Unit AH-28 (3)

Instrumentation 228 8-29-78 E

No RAB Blowdown Filter "A" Room "A", Air Handling Unit AH-27 (3)

Instrumentation 244 2

12-14-79 E

No Reactor Cavity Cooling System Instrumentation S-2(3A) & S-2 (3B) 249 2

7-23-79 E

No Turbine Area Supply Fan S-10 (3) 250 2

7-23-79 E

No Typical Turbine Area Exhaust Fan 257 2

12-14-79 E

No Annulus Negative Pressure System 258 0

9-29-78 E

No Airborne Radioactivity Removal System Fan E-13 (3A) 259 0

9-29-78 E

No Airborne Radioactivity Removal System Fan E-13 (3B) 273 0

9-29-78 E

No Fuel Handling Building Normal Exhaust Fans E-20 (3A) & E-20(3B) 277 0

9-29-78 E

No CEDM Fans (Inlet) 278 0

2-12-78 E

No CEDM Fans E-16(3A), E-16(3B), E-16(3C) & E-16(3D) 279 0

9-29-79 E

No Reactor Aux. Bldg. AH-5(3) & E-47(3)

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 9 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (B) Instrument Schematics and Logic Diagrams - Non-Safety Related B-431 280 0

9-29-78 E

No Reactor Aux Bldg. AH-8(3) 281 0

9-29-78 E

No RAB Smoke Purge Fans E-48(3) & E-50(3) 282 0

9-29-78 E

No Cable Vault Area Exhaust Fan E-49(3) 286 0

9-29-78 E

No Containment Fan Coolers Condensate Flow Detection 287 0

2-25-81 E

No Turbine Bldg. Swgr Unit AH-15(3) 288 0

2-25-81 E

No Turbine Bldg. Swgr Unit AH-29(3) 290 0

9-29-78 E

No Computer Room Supplemental Air Handling System AH-31(3) 291 0

10-16-78 E

No Hot Machine Shop Ventilation System 292 2

12-19-78 E

No Decontamination Facility Ventilation System 293 1

10-16-78 E

No RAB Normal Supply Fans 294 1

12-19-79 E

No RAB Normal Exhaust Fans

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 10 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related B-424 I

Open 9-82 E

No Index II Open 9-82 E

No Index III Open 9-82 E

No Index IV Open 9-82 E

No Index V

Open 9-82 E

No Index VI Open 9-82 E

No Index VII Open 9-82 E

No Index VIII Open 9-82 E

No Index IX Open 9-82 E

No Index X

Open 9-82 E

No Index XI Open 9-92 E

No Index XII Open 9-82 E

No Index XIII Open 9-82 E

No Index XIV Open 9-82 E

No Index XV Open 9-82 E

No Index XVI Open 9-82 E

No Index XVII Open 9-82 E

No Index XVIII Open 9-82 E

No Index XIX Open 9-82 E

No Index XX Open 9-82 E

No Index XXI Open 9-82 E

No Index XXII Open 9-82 E

No Index XXIV 1

9-82 E

No List of Abbreviations XXV 1

9-82 E

No List of Abbreviations XXVI 1

9-82 E

No List of Abbreviations XXVII 1

9-82 E

No List of Abbreviations XXVIII 1

9-82 E

No List of Abbreviations XXIX 1

9-82 E

No List of Abbreviations XXX 1

9-82 E

No List of Abbreviations XXXI 1

9-82 E

No List of Abbreviations XXXII 1

9-82 E

No List of Abbreviations XXXIII 0

9-82 E

No Device Numbers and Definitions XXXIV 0

9-82 E

No Device Numbers and Definitions XXXV 0

9-82 E

No Device Numbers and Definitions XXXVI 0

9-82 E

No Device Numbers and Definitions XXXVII 0

9-82 E

No Device Numbers and Definitions XXXVIII 0

9-82 E

No Device Numbers and Definitions XL 1

10-21-78 E

No Graphical Symbols XLI 0

10-21-78 E

No Graphical Symbols

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 11 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 XLII 0

2-28-80 E

No Typical Breaker Closing Ciruits XLIII 2

4-11-80 E

No Typical Plug Connection Diagram XLIV 0

2-28-80 E

No Isolation Relays - Typcial Wiring Diagrams IS 9

9-82 E

No CEA Drive MG Set A Supply BKR 3S 10 8-82 E

No CFA Drive MG Set B Supply BKR 5S 7

10-27-80 E

No Reactor Trip Bkr TCBI 6S 6

10-27-80 E

No Reactor Trip Bkr TCH2 7S 7

9-82 E

No Reactor Trip Bkr TCB3 8s 6

10-27-80 E

No Reactor Trip Bkr TCB4 9s 5

10-27-80 E

No Reactor Trip Bkr TCB5 10s 5

10-27-80 E

No Reactor Trip Bkr TCB6 11s 5

10-27-80 E

No Reactor Trip Bkr TCB7 12S 5

10-27-80 E

No Reactor Trip Bkr TCB8 13S 7

10-27-80 E

No Reactor Trip Bkr TCB9 21S 10 9-82 E

No CEA No. 1 22S 9

9-82 E

No CEA No. 2 23S 9

9-82 E

No CFA No. 3 24S 8

9-82 E

No CEA No. 4 25S 9

9-82 E

No CEA No. 5 26S 9

9-82 E

No CEA No. 6 27S 8

9-82 E

No CEA No. 7 28S 8

9-82 E

No CEA No. 8 29S 9

9-82 E

No CEA No. 9 30S 8

9-82 E

No CEA No. 10 31S 8

9-82 E

No CFA No. 11 32S 8

9-82 E

No CEA No. 12 33S 8

9-82 E

No CFA No. 13 34S 8

9-82 E

No CEA No. 14 35S 9

9-82 E

No CEA No. 15 36S 8

9-82 E

No CEA No. 16 37S 9

9-82 E

No CEA No. 17 38S 8

9-82 E

No CEA No. 18 39S 8

9-82 E

No CEA No. 19 40S 8

9-82 E

No CEA No. 20 41S 8

9-82 E

No CEA No. 21 42S 8

9-82 E

No CEA No. 22 43S 9

9-82 E

No CEA No. 23 44S 8

9-92 E

No CEA No. 24 45S 8

9-82 E

No CEA No. 25

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 12 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 46S 9

9-82 E

No CEA No. 26 47S 8

9-82 E

No CEA No. 27 48S 8

9-82 E

No CEA No. 28 49S 8

9-82 E

No CEA No. 29 50S 8

9-82 E

No CEA No. 30 51S 8

9-82 E

No CEA No. 31 52S 8

9-82 E

No CEA No. 32 53S 9

9-82 E

No CEA No. 33 54S 8

9-82 E

No CEA No. 34 55S 8

9-82 E

No CEA No. 35 56S 8

9-82 E

No CEA No. 36 57S 9

9-82 E

No CEA No. 37 5as 9

9-82 E

No CEA No. 38 59S 9

9-82 E

No CEA No. 39 60S 8

9-82 E

No CEA No. 40 61S 8

9-82 E

No CFA No. 41 62S 8

9-82 E

No CEA No. 42 63S 8

9-82 E

No CEA No. 43 64S 9

9-82 E

No CEA No. 44 65S 8

9-82 E

No CEA No. 45 66S 8

9-82 E

No CEA No. 46 67S 8

9-82 E

No CEA No. 47 68S 8

9-82 E

No CEA No. 48 69S 8

9-82 E

No CEA No. 49 70S 9

9-82 E

No CEA No. 50 71S 8

9-82 E

No CRA No. 51 72S 10 9-82 E

No CEA No. 52 73S 10 9-82 E

No CEA No. 53 74S 9

9-82 E

No CEA No. 54 75S 9

9-82 E

No CEA No. 55 76S 9

9-82 E

No CEA No. 56 77S 8

9-82 E

No CEA No. 57 78S 8

9-82 E

No CEA No. 58 79S 8

9-82 E

No CEA No. 59 80S 8

9-82 E

No CEA No. 60 81S 8

9-82 E

No CEA No. 61 82S 8

9-82 E

No CEA No. 62 83S 8

9-82 84S 8

9-82 E

No CEA No. 64

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3 (DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 13 of 47)

Revision 307 (07/13)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 85S 8

9-82 E

No CEA No. 65 86S 9

9-82 E

No CEA No. 66 87S 8

9-82 E

No CEA No. 67 88S 8

9-82 E

No CEA No. 68 89S 8

9-82 E

No CEA No. 69 90S 8

9-82 E

No CEA No. 70 91s 8

9-82 E

No CEA No. 71 92S 8

9-82 E

No CEA No. 72 93S 8

9-82 E

No CEA No. 73 94S 8

9-82 E

No CEA No. 74 95S 9

9-82 E

No CEA No. 75 96S 8

9-82 E

No CEA No. 76 97S 9

9-82 E

No CEA No. 77 98S 8

9-82 E

No CEA No. 78 99S 8

9-82 E

No CEA No. 79 100S 8

9-82 E

No CEA No. 80 101S 8

9-82 E

No CEA No. 81 102S 8

9-82 E

No CEA No. 82 103S 8

9-82 E

No CEA No. 83 104S 9

9-82 E

No CEA No. 84 105S 8

9-82 E

No CEA No. 85 106S 9

9-82 E

No CEA No. 86 107S 8

9-82 E

No CEA No. 87 (EC-2800, R307)

(EC-2800, R307) 113S 4

9-82 E

No Excore Neutron Flux Protective Channel A 114S 4

9-82 E

No Excore Neutron Flux Protective Channel B 115S 4

9-82 E

No Excore Neutron Flux Protective Channel C 116S 4

9-82 E

No Excore Neutron Flux Protective Channel D 119S 9

9-82 E

No Incore Neutron Flux Det 93A-L16 & 93A-G18 Incore Neutron Flux 120S 9

9-82 E

No Det 93A-E20 & 93A-GI3 Incore Neutron Flux 121S 8

9-82 E

No Det 95A-A14 & 95A-C9 Incore Neutron Flux (DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 14 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 122S 8

9-82 E

No Det 95A-E6 & 96A-C2 Incore Neutron Flux 123S 8

9-82 E

No Det 96A-C4 & 98A-T2 Incore Neutron Flux 124S 8

9-82 E

No Det 98A-19 & 98AR4 Incore Neutron Flux 125S 8

9-82 E

No Det 100A-T16 & 101A-WI8 Incore Neutron Flux 126S 8

9-82 E

No Det 92B-R18 & 92B-120 Incore Neutron Flux 127S 8

9-82 E

No Det 94B-E16 & 94B-C18 Incore Neutron Flux 128S 8

9-82 E

No Det 96B-E2 & 97B-G6 129S 8

9-82 E

No Incore Neutron Flux Det 97B-R2 & 97B-G4 130S 8

9-82 E

No Incore Neutron Flux Det 99B-W4 & 99B-T9 131S 8

9-92 E

No Incore Neutron Flux Det 99B-R13 & 99B-T6 132S 8

9-92 E

No Incore Neutron Flux Det 100B-Y8 & 101B-T20 133S 9

9-82 E

No Incore Neutron Flux Det 92C-C20 & 93C-G16 134S 8

9-82 E

No Incore Neutron Flux Det 93C-L13 & 94C-C9 135S 8

9-82 E

No Incore Neutron Flux Det 94C-C16 & 9SC-E9 136S 8

9-82 E

No Incore Neutron Flux Det 96C-E4 & 96C-Ag 137S 8

9-82 E

No Incore Neutron Flux Det 97C-L2 & 98C-R6 138S 8

9-82 E

No Incore Neutron Flux Det 99C-W6 & 100C-W13 139S 8

9-82 E

No Incore Neutron Flux Det 100C-T13 & I0IC-T18 140S 8

9-82 E

No Incore Neutron Flux Det 92D-L1B & 92D-R16

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 15 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 141S 8

9-82 R

No Incore Neutron Flux Det 93D-E18 & 94D-EI3 142S 8

9-82 E

No Incore Neutron Flux Det 95D-C13 & 96D-C6 143S 8

9-82 E

No Incore Neutron Flux Det 97D-L4 & 98D-T4 144S 8

9-82 E

No Incore Neutron Flux Det 98D-L6 & 99D-R9 145S 8

9-82 E

No Incore Neutron Flux Det 1OOD-W9 & 101D-Y14 146S 8

9-82 E

No Incore Neutron Flux Det 101D-W16 & 101D-R20 147S 5

9-82 E

No Incore Thermocouples SH. 1 148S 5

9-9-80 E

No Incore Thermocouples SH. 2 149S 5

9-82 E

No Incore Thermocouples SH. 3 150S 5

9-9-80 E

No Incore Thermocouples SH. 4 151S 5

9-9-80 E

No Incore Thermocouples SH. 5 152S 5

9-9-80 E

No Incore Thermocouples SH. 6 153S 5

9-9-80 R

No Incore Thermocouples SH. 7 154S 5

9-9-80 E

No Incore Thermocouples SH. 8 160S 8

9-82 E

No ESFAS Auxiliary Relay Cab A Alarms Sh. 1 162S 2

10-4-78 E

No ESFAS Auxiliary Relay Cab A Test Module 165S 3

9-82 E

No ESFAS Auxiliary Relay Cab B Alarms Sh. 1 167S 2

3-9-79 E

No ESFAS Auxiliary Relay Cab B Test Module 170S 8

9-82 E

No ESFAS Auxiliary Relays 176S 8

9-26-79 E

No Auxiliary Protective Cab Computer & Alarm Channel A 177S 10 9-82 E

No Auxiliary Protective Cab Computer

& Alarm Channel B 178S 10 9-82 E

No Auxiliary Protective Cab Computer

& Alarm Channel C 179S 9

9-82 E

No Auxiliary Protective Cab Computer

& Alarm Channel D 180S 2

9-82 E

No Auxiliary Protective Cab Interconnections 188S 4

9-82 E

No Control Board Mounted Nuclear Instrumentation Sh. 2 189S 7

9-82 E

No Control Board Mounted Nuclear Instrumentation Sh. 3

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 16 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 19is 3

3-22-79 E

No Control Board Mounted Nuclear Instrumentation Sh. 5 193S 2

3-27-79 E

No Control Board Miscellaneous Instrumentation Sh. 2 194S 4

4-3-79 E

No Control Board Miscellaneous Instrumentation Sh. 3 195S 4

9-82 E

No Control Board Miscellaneous Instrumentation Sh. 4 199S 7

9-82 E

No Power Supplies Pnl's CP-25, 26, 27, 28, 29, 30, 31 201S 9

9-82 E

No RCS Loop 1 Temp (Hot Leg) 202S 9

9-82 E

No RCS Loop 2 Temp (Hot Leg) 207S 9

9-82 E

No RCS Loop 1 Temp (Cold Leg) 208S 9

9-82 E

No RCS Loop 2 Temp (Cold Leg) 210S 7

9-82 E

No Steam Gen No. 1 Press Sh. 1 211S 4

9-82 E

No Steam Gen No. 1 Press Sh. 2 212S 7

9-82 E

No Steam Gen No. 1 Level Sh. 1 213S 4

9-82 E

No Steam Gen No. 1 Level Sh. 2 215S 7

9-82 E

No Steam Gen No. 2 Press Sh. 2 216S 4

9-82 E

No Steam Gen No. 2 Press Sh. 2 217S 4

9-82 E

No Steam Gen No. 2 Level Sh. 1 218S 5

9-82 E

No Steam Gen No. 2 Level Sh. 2 225S 11 9-82 E

No Reactor Coolant Pump 1A Alarms and Computer Input Sh 2 226S 4

9-82 E

No Reactor Coolant Pump 1A Protective Speed 235S 14 9-82 E

No Reactor Coolant Pump 1B Alarms and Computer Inputs Sh 2 236S 3

9-82 E

No Reactor Coolant Pump 1B Protective Speed 245S 12 9-82 E

No Reactor Coolant Pump 2A Alarms and Computer Inputs Sh 2 246S 3

9-82 E

No Reactor Coolant Pump 2A Protective Speed 255S 14 9-82 E

No Reactor Coolant Pump 2B Alarms and Computer Inputs Sh 2

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 17 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE

 (DRN 01-758, R11-A)

(C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 256S 3

9-82 E

No Reactor Coolant Pump 2B Protective Speed 262S 6

9-82 E

No Loose Parts Monitoring System Sh 3 266S 6

9-82 E

No Pressurizer Press (Narrow Range)

Sh 3 267S 6

9-82 E

No Pressurizer Press (Wide Range)

Sh 4 268S 5

9-82 E

No Pressurizer Press (Wide Range)

Sh 5 269S 6

9-82 E

No Pressurizer Press Sh 6 270S 10 9-82 E

No Pressurizer Press (Wide Range)

Sh 7 273S 9

9-82 E

No Pressurizer Level Sh 1 275S 6

9-82 E

No Pressurizer Level Sh 3 278S 2

9-82 E

No Subcooled Marg. Monitor Channel A 279S 2

9-82 E

No Subcooled Marg. Monitor Channel B 294S 3

9-82 E

No Pressurizer Aux Spray Valve ICH-E2505A 295S 4

9-82 E

No Pressurizer Aux Spray Valve ICH-E2505B 300S 8

9-82 E

No Letdown Stop V& ICH-FIS16A/B 301S 7

9-82 E

No Letdown Cont Isol Valve ICH-F25OIA/B 302S 6

8-27-80 E

No Letdown Cont Isol Valve 2CH-FI51BA/B 325S 6

9-82 E

No RCP Bleedoff Cont Isol Valves 2CH-FIS12A/B &

2CH-FIS13A/B 327S 5

9-82 E

No Volume Control Tk Disch Valve 2CH-VI23A/B 337S 4

2-7-79 E

No Boric Acid Gravity Feed Valve 3CH-VI06A 338S 3

11-28-79 E

No CVCS System A Heat Tracing 340S 7

12-18-79 E

No Boric Acid Makeup Tk B Heater 2-1 341S 8

1-17-80 E

No Boric Acid Makeup Tk B Heater 2-2 342S 4

2-26-79 E

No Boric Acid Gravity Feed Valve 3CH-VlO7B 343S 4

9-82 E

No CVCS System B Heat Tracing 345S 6

9-92 E

No Boric Acid Pump A 346S 5

9-82 E

No Boric Acid Pump A Recirc Valve 3CH-Fl7OA 350S 6

9-82 E

No Boric Acid Pump B 351S 4

5-16-79 E

No Boric Acid Pump B Recirc Valve & 3CH-FI71B 357S 5

9-82 E

No Reactor Makeup Stop Valve 3CH-FI17A/B 358S 6

9-92 E

No Reactor Makeup Bypass Valve 3CH-VI12A/B

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 18 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 365S 5

9-82 E

No Charging Pump A 366S 8

9-82 E

No Charging Pump A Seal Lube Pump 370S 4

9-92 E

No Charging Pump A/B 371S 8

9-82 E

No Charging Pump A/B Seal Lube Pump 375S 4

9-82 E

No Charging Pump B 376S 8

9-82 E

No Charging pump B Seal Lube Pump 381S 8

9-82 E

No Charging Line to loop 1A; Shutoff Valve ICH-E2503A 382S 8

9-82 E

No Charging Line to loop 2A; Shutoff Valve ICH-E2504B 402S 4

9-82 E

No Reactor Drain Tk Cont Isol Valves 2BM-FIOBA/B & 2BM-FI09A/B 490S 8

9-82 E

No Refueling Water Tk Level Sh 1 492S 5

11-19-80 E

No Refueling Water Storage Pool Outlet Valve 2SI-L103A 493S 7

9-82 E

No SIS Sump Isol Valve 2SI-L101A 495S 6

9-82 E

No Refueling Water Storage Pool Outlet Valve 2SI-LI04D 496S 6

9-82 E

No Cont Sump Isol Valve 2SI-L102B 498S 6

9-82 E

No Cont Isol from SI TK Drain To RWP Valve 2SI-FI561A/B 500S 8

9-82 E

No High Press Safety inj Pump A 502S 4

9-82 E

No High Press SI Header A Orifice Bypass Valve 2SI-VIS34 503S 5

9-82 E

No Reactor Coolant Loop I Hot Leg Flow Contr Valve 2SI-VI556 504S 5

9-82 E

No Reactor Coolant Loop I Hot Let Inj Isol Valve 251-VIS57 507S 5

9-82 E

No High Press Safety Inj Pump A/B 509S 7

9-82 E

No High Pressure Safety Inj Pump B 511S 3

9-82 E

No High Pressure SI Header B Orifice Bypass Valve 2SI-V811B 512S 5

9-82 E

No Reactor Coolant Loop 2 Hot Leg Flow Contr Valve 2SI-Vl559 513S 4

9-82 E

No Reactor Coolant Loop 2 Hot Let Inj Isol Valve & 2SI-VI558 516S 5

9-82 E

No Safety Inj Pumps A Min Flow Isol Valve 2SI-V809A

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 19 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 517S 5

9-82 E

No Safety Inj Pumps A Min Flow Isol Valve 2SI-VB10A 518S 5

9-82 E

No Safety Inj Pumps B Min Flow Isol Valve 2SI-V801B 519S 6

9-82 E

No Safety Inj Pumps B Min Flow Isol Valve 2SI-V802B 520S 1

9-82 E

No LPSI Pumps Min. Flow isolation Valves 2ST-EI587A and 2SI-EI588B 521S 5

9-82 E

No High Press SI Flow Cont Valve 2ST-VI550AI 522S 5

9-82 E

No High Press Sl Flow Cont Valve 2SI-VIS46A2 523S 5

9-82 E

No High Press Sl Flow Cont Valve 2SI-VI542A3 524S 5

9-82 E

No High Press Sl Flow Cont Valve 2SI-VI548A4 525S 6

9-82 E

No High Press SI Flow Cont Valve 2SI-VIS4681 526S 6

9-82 E

No High Press Sl Flow Cont Valve 2SI-V]54OB2 527S 5

9-82 E

No High Preas Si Flow Cont Valve 2SI-VI547B3 528S 6

9-82 E

No High Press SI Flow Cont Valve 2SI-VI544B4 530S 4

9-2-80 E

No Low Press Safety Inj Pump A 532S 3

3-9-79 E

No Shutdown & Cooling Line A Bypass Valve 2SI-FM317A 533S 2

10-4-78 E

No Shutdown Cooling Flow Control Valve 2SI-FM318A 535S 4

9-2-80 E

No Low Press Safety Inj Pump B 537S 2

10-4-78 E

No Shutdown Cooling Line B Bypass Valve SI-FM348B 538S 2

10-4-78 E

No Shutdown Cooling Flow Contr Valve SI-FM349B 539S 4

9-82 E

No Shutdown Line to RCS Loop I 541S 7

9-82 E

No Low Press Sl Flow Contr Valve 2SI-VI549AI 542S 7

9-82 E

No Low Press Sl Flow Contr Valve 2SI-VIS39BI 543S 6

9-82 E

No Low Press Sl Flow Contr Valve 2SI-VI54IA2 544S 7

9-82 E

No Low Press Sl Flow Contr Valve 2SI-VI543B2 545S 4

9-11-80 E

No Nitrogen Cont Isol Valve 2NG-F605 &

2NG-F604 548S 8

9-82 E

No Shutdown Cooling Temp 552S 6

9-82 E

No SI Tak IA Isol Valve & ISI-VSO5 TKIA 553S 9

9-82 E

No SI Tnk IA Nitrogen Contr Valve & Vent Valve 554S 4

9-82 E

No SI Tnk 1A Leakage Drain Valve &

Fill Drain Valve 555S 6

9-82 9

No SI Tak IA Vent Valve 558S 6

9-92 E

No SI Tnk IB Isol Valve ISI-VI506 TKIB

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 20 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Safety Related (Cont'd)

B-424 559S 6

9-82 E

No SI Tnk IB Nitrogen Contr Valve &

Vent Va 560S 4

9-82 E

No SI Tak IR Leakage Drain Valve &

Fill Drain Valve 561S 6

9-82 E

No SI Tank IB Vent Valve 564S 7

9-82 E

No SI Tnk 2A Isol Valve ISI-VIS07 TK2A 565S 7

9-82 E

No SI Tak 2A Nitrogen Cont Valve 566S 4

9-82 E

No SI Tnk 2A Leakage Drain Valve &

Fill Drain Valve 567S 6

9-82 E

No SI Tnk 2A Vent Valve 570S 7

9-82 E

No SI Tnk 28 Isol Valve ISI-V15O8 Tk2B 571S 6

9-82 E

No SI Tnk 2B Nitrogen Contr Valve &

Vent Valve 572S 4

9-82 E

No SI Tnk 2B Leakage Drain Valve Fill Drain Valve 573S 7

9-82 E

No SI Tnk 2B Vent Valve 589S 5

9-82 E

No Shutdown Cool Heat Exch Instr 590S 10 9-82 E

No RCS Loop #1 Shutdown Cool Isol Valve ISI-VI502 591S 11 9-82 E

No RCS Loop #1 Shutdown Cool Isol Valve ISI-VI501B 592S 4

9-82 E

No RCS Loop #1 Shutdown Cool Isol Valve 2SI-V326B 593S 3

9-82 E

No RCS Loop #1 Hot Leg Inj Drain Valve ISI-VI578 594S 5

9-26-79 E

No Hydraulic Pump Motor RCS Loop #1 SHDN Cool Isol Valve 1SI-VI502B 595S 10 9-82 E

No RCS Loop #2 Shutdown Cool 1801 Valve 1SI-VI504A 596S 9

9-82 E

No RCS Loop #2 Shutdown Cool Isol Valve 1SI-VI503A 597S 3

2-21-79 E

No RCS Loop #2 Shutdown Cool Isol Valve ISI-V327 598S 3

9-82 E

No RCS Loop #2 Hot Leg Inj Drain Valve 1SI-VI577 599S 7

9-82 E

No Hydraulic Pump Motor RCS Loop #2 SHDN Cool Isol Valve 1SI-VI503A 604S 4

9-82 E

No Contaiment Spray Riser Level Pump 'A' 605S 6

9-82 E

No Containment Spray Pump A

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 21 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 607S 4

9-82 E

No Contaiment Spray Isolation Valve 2CS-F305A 608S 9

9-82 E

No Containment Spray Pump A Disch Press & Flow & Hisc Ann Inputs 609S 5

9-82 E

No Containment Spray Riser Level Pump 'B' 610S 8

9-82 E

No Containment Spray Pump B 612S 5

9-82 E

No Containment Spray Isolation Valve 2CS-306B 613S 8

9-82 E

No Containment Spray Pump B Disch Press & Flow & Misc Ann Inputs 618S 1

9-82 E

No Containment Pressure Instrumentation Isol. Valves 620S 4

9-92 E

No Containment Pressure Instrumentation SH 1 621S 6

9-82 E

No Containment Pressure Instrumentation SH 2 623S 12 9-82 E

No Containment Pressure & SIS Sump Temp & Level Instr SH 1 624S 14 9-82 E

No Containment Pressure & SIS Sump Temp & Level Instr SH 2 625S 8

9-82 E

No Containment Personnel Air Lock 680S 4

9-82 E

No Waste Gas Cont Isol Valves 700S 4

9-82 E

No Comp Cool Wtr Pumps Comon Circuits 2WM-FI57A/D & 2WM-FI58A/B 701S 6

6-27-90 E

No Comp Cool Suct Disch HDR Isol Valve 3CC-F13A/B, 3CC-FI09A/B 702S 6

6-27-80 E

No Comp Cool Suct Disch HDR Isol Valve 3CC-F14A/b, 3CC-FIIOA/B 703S 2

6-18-79 E

No Comp Cool Suct Disch HDR Isol Valve 3CC-F15A/B, 3CCFIIIA/B 704S 3

9-82 E

No Comp Cool Suct Disch HDR Isol Valve 3CC-F16A/B, 3CC-Fll2A/B 705S 6

9-82 E

No Comp Cool Wtr Pump A 707S 7

9-82 E

No Comp Cool Wtr Pump A/B 709S 4

9-82 E

No Comp Cool Wtr Pump B 713S 10 9-82 E

No Comp Cool Wtr System Instrumentation SH2 714S 8

9-82 E

No Comp Cool Wtr System Instrumentation SH3 715S 5

1-8-80 E

No Comp Cool Wtr System Instrumentation SH4 716S 6

9-82 E

No Comp Cool Wtr System Instrumentation SH5

731S, 5

2-18-80 E

No Dry Tower A Fan No. 1 732S 5

2-18-80 E

No Dry Tower A Fan No. 2 733S 5

2-18-80 R

No Dry Tower A Fan No. 3 734S 5

2-18-80 E

No Dry Tower A Fan No. 4 735S 5

2-18-80 E

No Dry Tower A Fan No. 5 736S 6

2-18-80 E

No Dry Tower A Fan No. 6 737S 5

2-18-80 E

No Dry Tower A Fan No. 7 738S 5

2-18-80 E

No Dry Tower A Fan No. 8 739S 5

2-18-80 E

No Dry Tower A Fan No. 9 740S 6

2-18-80 E

No Dry Tower A Fan No. 10

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 22 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 741S 5

2-18-80 E

No Dry Tower A Fan No. 11 742S 5

2-18-80 E

No Dry Tower A Fan No. 12 743S 5

2-18-80 E

No Dry Tower A Fan No. 13 744S 5

2-18-80 E

No Dry Tower A Fan No. 14 745S 5

2-18-80 E

No Dry Tower A Fan No. 15 749S 6

9-82 E

No Dry Tower Isol Valve 3CC-B201A & Bypass Valve 3CC-F265A 752S 5

9-82 E

No Aux Comp Coolant Pump A 753S 7

9-82 E

No Aux Comp Coolant Pump Alarms & Computer Inputs 761S 6

9-82 E

No Wet Tower A Fan No. 1 762S 4

9-82 E

No Wet Tower A Fan No. 2 763S 4

9-82 E

No Wet Tower A Fan No. 3 764S 4

9-82 E

No Wet Tower A Fan No. 4 765S 5

2-7-80 E

No Wet Tower A Fan No. 5 766S 4

9-82 E

No Wet Tower A Fan No. 6 767S 4

9-92 E

No Wet Tower A Fan No. 7 768S 7

9-82 E

No Wet Tower A Fan No. 8 770S 2

9-82 E

No Cool Tower A Motor Space Heaters 781S 4

2-18-80 E

No Dry Tower A Fan No. 1 782S 6

9-82 E

No Dry Tower A Fan No. 2 783S 5

9-82 E

No Dry Tower A Fan No. 3 754S 0

E No ACCW Pump A Disch. Line Isol. Valve 3CC-B288A 784S 6

9-82 E

No Dry Tower B Fan No. 4 785S 5

9-82 E

No Dry Tower B Fan No. 5 786S 5

9-82 E

No Dry Tower B Fan No. 6 787S 5

9-82 E

No Dry Tower B Fan No. 7 788S 5

9-82 E

No Dry Tower B Fan No. 8 789S 4

2-18-80 E

No Dry Tower B Fan No. 9 790S 4

2-18-80 E

No Dry Tower B Fan No. 10 791S 4

2-18-80 E

No Dry Tower B Fan No. 11 792S 6

9-82 E

No Dry Tower B Fan No. 12 793S 4

2-18-80 E

No Dry Tower B Fan No. 13 794S 4

2-18-80 E

No Dry Tower B Fan No. 14 795S 7

2-18-80 E

No Dry Tower B Fan No. 15 799S 4

4-17-79 E

No Dry Tower B Isol Valve 3CC-B203B & Bypass Valve 3CC-B262B 802S 4

9-82 E

No Auxiliary Component Cooling Water Pump B 803S 6

9-82 E

No Auxiliary Component Coolant Pump B Alarms and Computer Inputs 811S 4

5-16-79 E

No Wet Tower B Fan No. 1

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 23 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 812S 4

9-82 E

No Wet Tower B Fan No. 2 813S 4

9-82 E

No Wet Tower B FAn No. 3 814S 4

9-82 E

No Wet Tower B Fan No. 4 815S 5

9-82 E

No Wet Tower B Fan No. 5 816S 5

9-82 E

No Wet Tower B Fan No. 6 817S 5

9-82 E

No Wet Tower B Fan No. 7 818S 6

9-82 E

No Wet Tower B Fan No. 8 819S 3

1-3-79 E

No Wet Tower Level Equalizing Valves Cross Tie Valves 820S 2

9-82 E

No Cool Tower Motor Space Materials 821S 4

7-24-79 E

No Chillers Coolant Selective Valves Common CKT System "A" 822S 2

10-9-78 E

No Chillers Coolant Selective Valves 3CC-F272B & 3CC-F274A 823S 2

10-9-78 E

No Chillers Coolant Selective Valves 3CC-F276A & 3CC-F278A 824S 6

9-82 E

No Containment Fan Coolers Cool Coils Instr System "A" 826S 3

1-3-79 E

No Chillers Coolant Selective Valves Comon CKT System "B" 827S 3

5-10-79 E

No Chillers Coolant Selective Valves 3CC-F273B & 3CC-F275B 828S 3

5-11-79 E

No Chillers Coolant Selective Valves 3CC-F277H & 3CC-F279B 829S 7

9-82 E

No Containment Fan Coolers Cool Coils Instr Syst "B" 834S 5

6-27-80 E

No Component Coolant Isol Valve 3CC-FI22A 836S 6

9-82 E

No Component Coolant Isol Valve 3CC-Fl239 838S 2

9-25-78 E

No Component Coolant Isol Valve 3CC-133A/B 840S 5

9-82 E

No Fuel Pool Temp. Control Valve 3CC-FM 138AB CH A 841S 4

9-82 E

No Fuel Pool Temp. Control Valve 3CC-FM 138AB CH B 804S 0

E No ACCW Pump B Disch. Line Isol. Valve 3CC-B289B 843S 7

3-3-80 E

No Component Coolant Surge Tank Level Contr Valve 7OW-LM601 845S 6

9-27-80 E

No CCW to RC Pumps Coolant Valve 2CC-FI46A/B 846S 8

9-82 E

No CCW from RC Pumps Isol Valve 2CC-FI47A/B & 2CC-F243A/B 847S 3

5-11-79 E

No Shutdown Heat Exch A Outlet Valve 3CC-FI30A 848S 3

5-11-79 E

No Shutdown Heat Exch B Outlet Valve 3CC-FI31B 851s 8

9-82 E

No Component Coolant Makeup Pump A 852S 8

9-82 E

No Component Coolant Makeup Pump 8 854S 3

4-10-79 E

No CCW Makeup to Return Header Valve 3CC-F240A 855S 3

4-10-79 E

No CCW Makeup to Return Header Valve 3CC-F241B 859S 7

9-82 E

No DG'S Stand Pipes Level Contr Valve 3CC-L640A & 3CC-L641B 862S 9

9-82 E

No Containment Sump Pump Isolation Valves 908S 0

9-82 E

No Toxic Chemical Detection System SH. 5

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 24 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 911S 7

9-82 E

No Coolant Sampling Isol Valves 2SL-FI501A/B & 2SL-1504A/B 912S 6

9-82 E

No Pressurized Surge Line Cont Isol Valve 2SL-FI502 913S 7

9-82 E

No PZRD STH Space Sample Cont Isol Valves 2SL-FIS03A/B & 2SL-FI506A/B 922S 8

9-82 E

No STH GEN I Sample Isol Valves 2SL-F601 & 2SL-F602 923S 5

9-82 E

No STH GEN 2 Sample Isol Valves 2SL-F603 & 2SLF604 929S 4

8-27-80 E

No STH Line Sample Isol Valves 2MS-F714 & 2MS-F715 931S 3

9-82 E

No Reactor Coolant System Vent Valves SH. 1 932S 5

9-82 E

No Reactor Coolant System Vent Valves SH. 2 933S 3

9-82 E

No Reactor Coolant System Vent Valves SH. 3 934S 3

9-82 E

No Reactor Coolant System Vent Valves SH. 4 940S 1

9-82 E

No SIS Sump Sampling Cont. Isol. Valve 2SI-E648 951S 5

9-82 E

No Hydrogen Analyzer System A Sh 1 952S 8

9-82 E

No Hydrogen Analyzer System A Sh 2 953S 1

11-10-78 E

No Hydrogen Analyzer System A Inlet Pump 954S 1

11-10-78 E

No Hydrogen Analyzer System A Outlet Pump 955S 3

9-82 E

No Hydrogen Analyzer System B Sh 1 956S 6

9-82 E

No Hydrogen Analyzer System B Sh 2 957S 1

11-10-78 E

No Hydrogen Analyzer System B Inlet Pump 958S 2

5-11-79 E

No Hydrogen Analyzer System B Outlet Pump 960S 8

9-82 E

No Hydrogen Recombiner System A 962S 7

9-82 E

No Hydrogen Recombiner System 8 997S 5

8-27-80 E

No Instrument Air Cont Isol Valve 21A-F601AB

(DRN 01-758, R11-A) 1000S 7

9-10-79 E

No Charging Pump A Cooler AH-18 (3A-SA) 1001S 7

9-10-79 E

No Charging Pump AB Cooler AH-22 (3A-SAB) 1002S 6

9-10-79 E

No Charging Pump B Cooler AH-18 (3B-SB) 1003S 6

9-10-79 E

No Charging Pump AB Cooler AH-22 (3B-SAB) 1004S 7

9-82 E

No Safeguard Pump Room A Cooler AH-21 (3-SAB) 1005S 11 9-82 E

No Safeguard Pump Room A Cooler AH-2 (3A-SA) 1006S 9

9-82 E

No Safeguard Pump Room A Cooler AH-2 (3A-SA) 1007S 8

9-82 E

No Safeguard pump Room A Cooler AH-2 (3B-SB) 1008S 8

9-82 E

No Safeguard Pump Room A Cooler AH-2 (3D-SB)

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 25 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 1010S 7

9-10-79 E

No CCW Pump A Cooler AH-10 (3A-SA) 1011S 7

9-82 E

No CCW Heat Exch A Cooler AH-24 (3A-SA) 1012S 7

9-12-79 E

No CCW Pump AB Cooler AH-20 (3A-SAB) 1013S 7

9-12-79 E

No CCW Pump AB Cooler AH-20 (3B-SAB) 1014S 6

9-10-79 E

No CCW Pump B Cooler AH-10 (3B-SB) 1015S 7

8-25-80 E

No CCW Heat Exch B Cooler AH-24 (3B-SB) 1017S 8

8-25-80 E

No Shutdown Heat Exch A Cooler AH-3 (3A-SA) 1018S 8

8-25-80 E

No Shutdown Heat Exch B Cooler AH-3 (3B-SB) 1020S 8

9-10-79 E

No Emerg FWP A Cooler AH-17 (3A-SA) 1021S 8

9-10-79 E

No Emerg FWP A Cooler AH-17 (38-SB) 1026S 8

8-25-80 E

No Equipt Room Cooler AH-26 (3A-SA) 1027S 8

9-82 E

No Equipt Room Cooler AH-26 (3B-SB) 1031S 5

9-82 E

No Control Atmos Release System Supply Fan S-3 (3A-SA) 1032S 9

9-82 E

No Control Atmos Release System Exhaust Fan E-18 (3A-SA)

(DRN 01-758, R11-A) 1033S 5

9-82 E

No Control Atmos Release System

(DRN 01-758, R11-A)

Disch Valve 2KV-BI67A 1034S 7

9-82 E

No Control Atmos Release System Suct Valve-F253A 1035S 5

8-92 E

No Control Atmos Release System Supply Fan S-3 (38-SB) 1036S 11 9-82 E

No Control Atmos Release System Exhaust Fan E-18 (3B-SB)

Disch Valve 2HV-BI689 1037S 4

9-82 E

No Control Atmos Release System Disch Valve 2HV-BI68B 1038S 7

9-82 E

No Control Atmos Release System Shut Valve 2HV-F254B 1040S 9

9-92 E

No Diesel Gen A Room Vent System

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 26 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 1041S 5

9-82 E

No Diesel Gen A Room Exhaust Fan E-28 (3A-SA) 1042S 7

9-3-80 E

No Diesel Gen B Room Vent System 1043S 5

9-82 E

No Diesel Gen B Room Exhaust Fan E-28 (3B-SB) 1045S 5

9-82 E

No Water Chiller Compressor WC-1 (3A-SA) 1046S 5

9-82 E

No Water Chiller Compressor WC-1 (3A-SA) Oil Pump 1047S 3

4-17-79 E

No Water Chiller WC-1 (3A-SA)

Pump Out Compressor 1048S 6

9-82 E

No Chilled Water Pump P-1 (3A-SA) 1049S 9

9-82 E

No Chilled Water Sys RCC Va & Exp Tnk Lev Cnt Va 1050S 7

8-25-80 E

No Chilled Water System A Alarm & Computer Inputs 1051S 7

2-15-80 E

No Chilled Water System A Instrumentation Sh 1 1052S 6

9-82 E

No Chilled Water System A Instrumentation Sh 2 1055S 6

9-82 E

No Water Chiller Compressor WC-1 (3B-SB) 1056S 4

9-82 E

No Water Chiller WC-1 (3B-SB) Oil Pump 1057S 4

9-82 E

No Water Chiller WC-1 (38-SB) Pumpout Compressor 1058S 7

9-26-79 E

No Chilled Water Pump P-1 (3B-SB) 1059S 8

9-82 E

No Chilled Water Sys B Recirc Va & Exp Tank Level Contr Va 1060S 6

9-82 E

No Chilled Water Sys B Alarm & Computer Inputs 1061S 5

9-14-79 E

No Chilled Water Sys B Instrumentation Sh 1 1062S 5

9-14-79 E

No Chilled Water Sys 8 Instrumentation Sh 2 1065S 6

9-82 E

No Water Chiller Compressor WC-1 (3C-SAB) 1066S 6

9-82 E

No Water Cbiller WC-1 (3C-SAB) Oil Pump 1067S 4

9-82 E

No Water Chiller WC-1 (3C-SAB) Pumpout Compressor 1068S 8

9-82 E

No Chilled Water Pump P-1 (3C-SAB) 1069S 8

9-82 E

No Chilled Water System AB Recirc Va & Exp Tank Level Contr Va 1070S 7

9-82 E

No Chilled Water System AB Alarm & Computer Inputs 1071S 5

9-14-79 E

No Chilled Water System AB Instrumentation Sh I 1072S 4

9-14-79 E

No Chilled Water System AB Instrumentation Sh 2 1073S 7

9-82 E

No Chilled Water System Isolation Valves Sh I 1074S 6

9-82 E

No Chilled Water System Isolation Valves Sh 2 1075S 7

9-82 E

No Swgr Area Air Handling Unit AH-25 (3A-SA) 1076S 11 9-82 E

No AH-25 (3A-SA) Electric Heating Coil EHC-36 (3A-SA) 1077S 9

9-82 E

No AH-25 (3A-SA) Chilled Water Contr Valve & Hisc 1079S 5

9-82 E

No Swgr Area Air Handling Unit AH-25 (3B-SB) 1080S 10 9-82 E

No AH-25 (3B-SB) Electric Heating Coil EHC-36 (3B-SB) 1081S 9

9-82 E

No AH-25 (3B-SB) Chilled Water Contr Valve & Misc

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 27 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 1083S 6

9-82 E

No Battery Room A Exhaust Fan E-29 (3A-SA) 1084S 8

9-82 E

No Battery Room A Exhaust Fan E-29 (3B-SB) 1085S 8

9-82 E

No Battery Room Fans Cooler E-52 (3A-SA) 1086S 5

9-82 E

No Battery Room AB Exhaust Fan E-31 (3A-SA) 1087S 4

11-14-79 E

No Battery Room AB Exhaust Fan E-31 (3B-SB) 1088S 6

9-82 E

No Battery Room Fan Cooler E-52 (3B-SB) 1089S 4

5-7-79 E

No Battery Room B Exhaust Fan E-30 (3B-SB) 1090S 5

9-82 E

No Battery Room Exhaust Fan E-30 (3B-SB) 1092S 5

5-7-79 E

No Computer Battery Room Exhaust Fan E-00 (3A-SA) 1093S 5

11-28-79 E

No Computer Battery Room Exhaust Fan E-00 (3B-SB) 1099S 7

9-82 E

No Annulus Negative Press Sys Sh 3 1110S 3

6-18-79 E

No CVAS Isolation Valves SH1 1111S 2

6-18-79 E

No CVAS Isolation Valves Sh2 1113S 6

9-82 E

No CVAS Exhaust Fan E-23 (3B-SA) 1114S 8

9-82 E

No CVAS Exhaust Fan E-23 (3B-SB) 1115S 3

1-8-80 E

No CVAS Electric Heating Coil EHC-48 (3A-SA) 1116S 3

9-82 E

No CVAS Electric Heating Coil EHC-48 (3A-SA) 1117S 5

11-14-79 E

No RAB HVAC Equip Room Supply Fan AH-13 (3A-SA) 1119S 5

3-19-79 E

No RAB HVAC Equip,Room Supply Fan AH-13 (3B-SB) 1121S 5

11-14-79 E

No RAB HVAC Equip Room Exhaust Fan E-41 (3A-SA) 1122S 5

11-14-79 E

No RAB HVAC Equip Room Exhaust Fan E-41 1123S 7

9-82 E

No RAB HVAC Equip Room Elec Htg Coil ECH-55 (3A) 1124S 7

9-82 E

No RAB HVAC Equip Room Elec Htg Coil EHC-55 (3B) 1128S 10 9-82 E

No Cont Purge Isol VA'S Shl, 1129S 9

9-82 E

No Cont Purge Isol VA's Sh2 1130S 9

9-82 E

No Cont Vacuum Relief VA 2HV-BI56A 1131S 12 9-82 E

No Cont Vacuum Relief VA 2HV-BI57B 1132S 7

9-82 E

No Cont Fan Cooler AH-1 (3A-SA) 1133S 5

9-82 E

No Cont Fan Cooler AH-1 (3C-SA) 1134S 9

9-82 E

No Cont Fan Cooler Syst A Valves 1135S 6

9-82 E

No Cont Fan Cooler AH-1 (3B-SB) 1136S 5

9-82 E

No Cont Fan Cooler AH-1 (3D-SB)

(DRN 01-758, R11-A) 1137S 8

9-82 E

No Containment Fan Coolers System B Valves 1138S 8

9-82 E

No Containment Fan Coolers Instrumentation

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 28 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 1146S 5

9-92 E

No Contr Room Emerg Filtr Unit A Intake and Return Air Dampers Comm Cont SH 1 1147S 7

9-82 E

No Contr Room Emerg Filtr Unit B Intake and Return Air Dampers Comm Cont SH 2 1148S 8

9-82 E

NO Contr Room Emerg Filtr Unit S-8 (3A-SA) 1149S 11 9-82 E

No S-8 (3A-SA) Electric Heating Coil EHC-49 (3A-SA) 1150S 5

9-82 E

No Contr Room Filtr Unit S-8 (3B-SD) 1151S 10 9-82 E

No S 8 (3B-SB) Electric Heating Coil EHC-49 (3B-SB) 1152S 5

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B196A 1153S 5

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B197A 1154S 3

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B198A 1155S 3

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B199A 1156S 5

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B201A 1157S 4

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B200B 1158S 3

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B203A 1159S 3

9-82 E

No Control Rm Emerg Filtr Unit Intake Valve 3HV-B202B 1160S 7

9-82 E

No Control Room Toilet Exhaust Fan E-34 (3A-SA) 1161S 8

9-82 E

No Control Room Toilet Exhaust Fan E-34 (3B-SB) 1162S 2

9-82 E

No Control Room Area Norm & Purge Dampers D-45, D-46, D-68 1164S 6

9-82 E

No Contr Rm Confer Rm & Kitchen Exh Fan Disch Valves & Dampers

(DRN 01-758, R11-A) 1165S 7

9-82 E

No Contr Room Air Handling Unit AH-12 (3A-SA) 1166S 8

9-82 E

No AH-12 (3A-SA) Electric Heating Coil EHC-34 (3AS) 1167S 6

9-82 E

No Contr Room Air Handling Unit AH-12 (3B-SE) 1168S 7

9-82 E

No AH-12 (3B-SB) Electric Heating Coil EHC-34 (3B-SB) 1232S 10 9-82 E

No FHB Vent Sys Exhaust Fan E-21 (3A-SA) 1233S 10 9-82 E

No FHB Vent Sys Exhaust Fan E-21 (3B-SH) 1234S 6

3-3-80 E

No FHB Vent System Emerg Filter Unit E-35 (3A-SA) 1235S 8

9-82 E

No E-35 (3A-SA) Electric Heating Coil

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 29 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 1236S 5

2-5-80 E

No FHB Vent Sys Emerg Filtr Unit E-35 (3B-SB) 1237S 10 9-82 E

No E-35 (3B-SR) Electric Heating Coil 1238S 5

9-82 E

No FHB Isolation Dampers SH1 1239S 6

9-82 E

No FHB Isolation Dampers SH2 1242S 4

8-25-80 E

No SWGR Area Air Holding Unit AH-30 (3A-SA) 1243S 5

9-82 E

No AH-30 (3A-SA) Chilled Wtr Contr VA & Hisc 1245S 3

8-25-80 E

No SWGR Ares Air Handling Unit AH-30 (3B-SB) 1246S 7

9-82 E

No AH-30 (3B-SB) Chilled Wtr Contr VA & Misc 1250S 7

9-82 E

No Shield Bldg Vent Sys Fan E-17 (3A-SA) 1252S 4

9-82 E

No Shield Bldg Vent Sys Train Inlet 2HV-BI60A 1253S 6

9-82 E

No Shield Bldg Vent Sys Train Outlet 2HV-BI58A 1254S 8

9-82 E

No Electric Heater Coil EHC-51 (3A-SA) 1255S 5

9-82 E

No Shield Bldg. Vent Syst A Exch VA 2HV-BI622A 1256S 2

9-82 E

No Shield Bldg. Vent Syst A Recirc VA 2HV-BI64A 1257S 8

9-82 E

No Shield Bldg. Vent Syst A Aux Exch VA 2HV-BI73A 1259S 7

9-82 E

No Shield Bldg. Vent Sys Fan E-17 (3B-SB) 1261S 4

9-82 E

No Shield Bldg. Vent Sys Train Inlet 2HV-BI61B 1262S 6

9-82 E

No Shield Bldg Vent Sys Train Outlet 2HV-:159B 1263S 5

9-82 E

No Electric Heating Coil EHC-51 (3B-SB) 1264S 5

9-82 E

No Shield Vent Syst B Exh VA 2HV-BI63B 1265S 2

4-5-79 E

No Shield Bldg Vent Syst B Recirc VA 2HV - B165B 1266S 9

9-82 E

No Shield Bldg Vent Syst B Aux Exh VA 2HV - B173B 1268S 3

9-82 E

No CVAS A Train Inlet VA 3HV B208A 1269S 2

4-5-79 E

No CVAS A Train Outlet VA 3HV B206A 1270S 8

9-82 E

No CVAS A Train Instrumentation 1271S 4

9-82 E

No CVAS B Train Inlet VA 3HV - B209B 1272S 2

4-5-79 E

No CVAS B Train Outlet 3HV - B209B 1273S 9

9-82 E

No CVAS Instrumentation 1274S 5

9-82 E

No CVAS A Train Min Flow Damper D-71 (SA) 1275S 5

9-82 E

No CVAS B Train Min Flow Damper D-71 (SB) 1326S 2

11-17-78 E

No Fire Wtr Cont Isol VA's 2FP-F127 & 2FP-F129 1509S 2

9-82 E

No Steam Gen. No. 1 Level (Wide Range) & EFW Flow 1510S 6

9-82 E

No SG No 1 Feedwater Isolation VA 2FV-V823A SH1 1511S 8

9-82 E

No SG No 1 Feedwater Isolation VA 2FV-823 SH2

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 30 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 1525S 2

9-82 E

No Steam Gen. No. 2 Level (Wide Range) & EFV Flow 1526S 6

9-82 E

No SG No 2 Feedwater Isolation VA 2FV-V824B SH1 1527S 9

9-82 E

No SG No 2 Feedwater Isolation VA 2FW-V824B SH2 1530S 10 9-82 E

No Condensate Storage Pool Inlet VA 6 CD-L362 & Instrumentation 1531S 6

9-82 E

No Emerg Feedwater Pump A 1533S 6

9-82 E

No Emerg Feedwater Pump B 1535S 2

11-14-79 E

No Emerg FWPT Stm Shutoff VA 2MS-V611A 1536S 1

10-9-78 E

No Emerg FWPT Sts Shutoff VA 2MS-V612B 1540S 8

9-82 E

No Emergency FWPT Stop Valve 1541S 7

9-82 E

No Emergency FWPT Gov Valve 1546S 5

9-82 E

No SG No 1 Emerg FV Isol VA's 2FW-V848A and 2FV-V852A 1547S 4

9-82 E

No SG No 1 Emerg FV Isol VA's 2FW-V8478 and 2FW-851B 1548S 5

9-82 E

No SG No 2 EMerg FV Isol VA's 2FW-849A 1549S 5

9-82 E

No SG No 2 Emerg FV Isol VA's 2FW-V850B and 2FW-V854B 1550S 8

9-82 E

No Emergency Feedwater Instrumentation 1551S 1

9-82 E

No SG No. 1 Emergency FW Contr. VA's 2FW-VB52A & V851B 1552S 1

9-82 E

No SG No. 2 Emergency FV Contr. VA's 2FW-V853A & V854B 1560S 4

9-82 E

No Steam Gen No. 1 Blowdown Cont Isol VA 2BD-F603 & 2RD-F604 1565S 6

9-82 E

No Steam Gen No. 2 Blowdown Cont Isol VA 2BD-F605 & 2BD-F606 1643S 4

9-14-79 E

No SG1 Main Sto Atmospheric Damp VA 2MS-PM629A 1644S 3

9-82 E

No STM Line 1 Upstream Normal Drain VA 2MS-V670 1645S 4

9-82 E

No STM Line 1 Upstream Emerg Drain VA 2MS-V671 1646S 6

9-82 E

No STM Line 1 Isolation 2MS-V602A SH1 1647S 8

9-82 E

No STM Line 1 Isolation 2MS-V602A SH2 1658S 5

9-14-79 E

No SG2 Main Stm Atmospheric Dump VA 2MS-PM 6308 1659S 3

12-18-79 E

No STM - Line 2 Upstream Normal Drain VA 2MS-V663 1660S 5

9-82 E

No STM - Line 2 Upstream Emerg Drain VA 2MS-V664 1661S 6

9-82 E

No STH - Line 2 Isolation VA 2MS-V604B SH1 1662S a

9-82 E

No STM Line 2 Isolation VA 2MS-V604B SH2 2090S 1

9-82 E

No Class IE Va's N2 Backup System No. 1 2091S 1

9-82 E

No Class IE Va's N2 Backup System No. 2

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 31 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 2092S 2

9-82 E

No Class IE Va's N2 Backup System No. 3 2093S 3

9-82 E

No Class IE Va's N2 Backup System No. 4 2094S 1

9-82 E

No Class IE Va's N2 Backup System No. 5 2095S 1

9-82 E

No Class IE Va's N2 Backup System No. 6 2096S 2

9-82 E

No Class IE Va's N2 Backup System No. 7 2097S 3

9-82 E

No Class IE Va's N2 Backup System No. 8 2098S 1

9-82 E

No Class IE Va's N2 Backup System Alarm 2301S 3

9-82 E

No Diesel Gen A Air Compressor A No. 1 2302S 3

9-82 E

No Diesel Gen A Air Compressor B No. 2 2304S 6

9-82 E

No Diesel Gen A Jacket Water Circulating Pump 2305S 6

9-82 E

No Diesel Gen A Jacket Water Heater 2306S 3

9-11-80 E

No Diesel Gen A Cooling Water Shut-off Valve 2308S 5

9-82 E

No Diesel Gen A Stanby Fuel Oil Booster Pump 2309S 6

9-82 E

No Diesel Gen A Fuel Oil Tranfer Pump 2311S 5

9-82 E

No Diesel Gen A Pre-Lube Oil Pump 2312S 3

9-82 E

No Diesel Gen A Standby Lube Oil Pump 2313S 7

9-82 E

No Diesel Gen A Lube Oil Heater 2314S 3

9-92 E

No Diesel Gen A Space Htr 2315S 5

9-82 E

No Diesel Gen A Generator Control Interface SH1 2316S 3

10-8-80 E

No Diesel Gen A Generator Control Interface SH2 2317S 3

10-8-80 E

No Diesel Gen A Generator Control Interface SH3 2318S 5

9-82 E

No Diesel Gen A Engine Control Interface SH1 2319S 2

9-92 E

No Diesel Gen A Engine Control Interface SH2 2320S 2

9-82 E

No Diesel Gen A Engine Control Interface SH3 2321S 4

9-82 E

No Diesel Gen A Engine Control Interface SH4 2322S 0

9-20-77 E

No Diesel Gen A Engine Control Interface SH5 2323S 11 9-82 E

No Diesel Gen A Engine Control Interface SH6 2324S 4

9-82 E

No Diesel Gen A Engine Control Interface SH7 2326S 7

9-82 E

No Diesel Gen B Computer Inputs SH2 2327S 6

9-82 E

No Diesel Generator A Breaker 2328S 6

9-82 E

No Diesel Generator A Comp Inputs SH3 2332S 7

9-82 E

No 4.16 KV Bus 3A3 Tie to Bus 3A2-S 2334S 7

9-82 E

No 4.16 KV Bus 3A3 Tie to Bus 3AB3-S 2335S 7

9-82 E

No 4.16 KV Bus 3AB3-S Tie to Bus 3A3-S 2336S 1

9-82 E

No 4.16 KV Bus 3A3 MTP Space Beaters 2337S 7

9-82 E

No 4.16 KV Bus 3A3-S Undervoltage Relays Test 2338S 3

9-82 E

No 4.16 KV Bus 3A3-1 Undervoltage Relays Test

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 32 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 2339S 5

9-82 E

No 480V Bus 3A31-S Undervoltage Relays Test 2340S 4

9-82 E

No 480V Bus 3A31-S Undervoltage Relays Test 2341S 4

9-82 E

No Sequencer A SH1 2342S 1

9-82 E

No Sequencer A SH2 2343S 1

8-27-80 E

No Sequencer A SH3 2346S 0

9-82 E

No STA Service Transformer 3A32 Feeder Interlocks 2347S 5

9-82 E

No STA Service Transformer 3A31-S Feeder 2348S 0

9-82 E

No STA Service Transformer 3A32 Feeder 2349S 5

9-82 E

No STA Service Transformer 3A315S Feeder 2351S 3

9-82 E

No Diesel Gen B Air Compressor No. 1 2352S 3

9-82 E

No Diesel Gen B Air Compressor No. 2 2354S 6

9-82 E

No Diesel Gen B Jacket Water Circulating Pump 2355S 6

9-82 E

No Diesel Gen B Jacket Water Heater 2356S 3

9-82 E

No Diesel Gen B Cool Water Shutoff Valve 2358S 5

9-82 E

No Diesel Gen B Standby Fuel Oil Booster Pump 2359S 6

9-82 E

No Diesel Gen B Fuel Oil Transfer Pump 2361S 5

9-82 E

No Diesel Gen B Pre-Lube Oil Pump 2362S 3

9-82 E

No Diesel Gen B Stanby Lube Oil Pump 2363S 5

9-82 E

No Diesel Gen B Lube Oil Heater 2364S 2

9-82 E

No Diesel Gen B Space Htr 2365S 5

9-82 E

No Diesel Gen B Generator Control Interface SH1 2366S 4

10-27-80 E

No Diesel Gen B Generator Control Interface SH2 2367S 4

10-27-80 E

No Diesel Gen B Generator Control Interface SH3 2368S 6

9-82 E

No Diesel Gen B Engine Control Interface SH1 2369S 2

9-82 E

No Diesel Gen B Engine Control Interface SH2 2370S 2

9-82 E

No Diesel Gen B Engine Control Interface SH3 2371S 2

9-82 E

No Diesel Gen B Engine Control Interface SH4 2372S 0

9-20-77 E

No Diesel Gen B Engine Control Interface SH5 2373S 10 9-82 E

No Diesel Gen B Engine Control Interface SH6 2374S 4

9-82 E

No Diesel Gen B Engine Control Interface SH7 2375S 5

9-82 E

No Diesel Gen B Computer Inputs SH1 2376S 8

9-82 E

No Diesel Gen B Computer Inputs SH2 2377S 6

9-82 E

No Diesel Generator B Breaker 2378S 4

9-82 E

No Diesel Generator B Computer Inputs SH3 2382S 6

9-82 E

No 4.16 KV Bus 3B3-S Tie to Bus 3B2 2384S 7

9-82 E

No 4.16 KV Bus 3B3-S Tie to Bus 3AB3-S

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 33 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 2385S 8

9-82 E

No 4.16 KV Bus 3AB3-S Tie to Bus 3B3-S 2386S 3

6-4-79 E

No 4.16 KB Bus 3B3-S Mtr Space Heaters 2387S 5

9-82 E

No 4.16 KV Bus 3B3-S Undervoltage Relays 2388S 3

9-82 E

No 4.16 KV Bus 3B3-S Undervoltage Relays 2389S 9

9-82 E

No 480V Bus 3B31-S Undervoltage Relays 2390S 5

9-82 E

No 480V Bus 3B31-S Undervoltage Relays Test 2391S 4

9-82 E

No Sequencer B SH1 2392S 2

9-82 E

No Sequencer B SH2 2393S 3

8-27-80 E

No Sequencer B SH3 2396S 0

9-82 E

No STA Service Transformer 3B22 Feeder Interlocks 2397S 4

9-82 E

No STA Service Transformer 3B31-S Feeder 2398S 7

9-82 E

No STA Service Transformer 3B32 Feeder 2399S 5

9-82 E

No STA Service Transformer 3B315-S Feeder 2406S 1

7-27-78 E

No 4.16 KV Bus 3AB3-S Mtr Space Heaters 2407S 2

9-82 E

No 4.16 KV Bus 3AB3-S Undervoltage Relays SH1 2408S 5

6-4-79 E

No 4.16 KV Bus 3AB-S Undervoltage Relays SH2 2409S 4

9-82 E

No 4.16 KV Bus 3AB3-S Undervoltage Relays Test 2410S 1

3-9-79 E

No 490V Bus 3AB31-S Undervoltage Relays 2411S 3

12-18-79 E

No 480V Bus 3AB31-S Undervoltage Relays Test 2477S 4

9-82 E

No 480V Bus 3A31-S Tie To Bus 3AB31-S 2479S 4

9-82 E

No 480V MCC 3A311-S Feeder 2480S 4

9-82 E

No 480V MCC 3A312-S Feeder 2481S 4

9-82 E

No 480V MCC 3A313-S Feeder 2482S 4

9-82 E

No 480V MCC 3A314-S Feeder 2483S 4

9-82 E

No 480V MCC 3A317-S Feeder 2486S 4

9-82 E

No 480V MCC 3A312-S Bus Isolation Bkr 2487S 3

9-82 E

No 480V MCC 3A313-S Bus Isolation Bkr 2488S 3

9-82 E

No 480V MCC 3A314-S Bus Isolation Bkr 2489S 3

9-82 E

No Computer Primary Feeder 2502S 5

9-82 E

No 480V Bus 3B31-S Tie To Bus 3AB31S 2504S 4

9-82 E

No 480V MCC 3B311-S Feeder 2505S 4

9-82 E

No 480V MCC 3B312-S Feeder 2506S 4

9-82 E

No 480V MCC 3B313-S Feeder 2507S 4

9-82 E

No 480V MCC 3B314-S Feeder 2508S 4

9-82 E

No 480V MCC 3B317-S Feeder 2511S 3

9-82 E

No 480V MCC 3B312-S Bus Isolation Bkr 2512S 4

9-82 E

No 480V MCC 3B313-S Bus Isolation Bkr 2513S 3

9-82 E

No 480V MCC 3B314-S Bus Isolation Bkr 2525S 3

9-10-79 E

No 480V Bus 3AB31-S Undervoltage Relays SH2

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 34 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 2527S 3

9-82 E

No 480V Bus 3AB31-S Tie to Bus 3A31-S 2529S 3

9-82 E

No 480V Bus 3AB31-S Tie to Bus 3B31-S 2531S 4

9-82 E

No 480V MCC 3AB311-S Feeder 2532S 4

9-82 E

No 480V MCC 3AB312-S Feeder 2533S 4

9-82 E

No 480V MCC 3AB313-S Feeder 2534S 1

9-82 E

No Computer Secondary Feeder 2537S 1

9-3-80 E

No 480V MCC 3A315-S Bus Boltage 2538S 1

9-82 E

No 208/120V AC PWR PNL 3B1-SA Feeder 2541S 1

9-3-80 E

No 480V MCC 3B315-S Bus Voltage 2542S 1

11-28-79 E

No 208/120V AC PWR PHL 3BI-SB Feeder 2550S 3

11-28-79 E

No Battery Charger 3A1-S Feeder 2551S 3

11-28-79 E

No Battery Charger 3A2-S Feeder 2552S 3

11-28-79 E

No Battery Charger 3B1-S Feeder 2553S 3

11-28-79 E

No Battery Charger 3B2-S Feeder 2554S 3

9-82 E

No Battery Charger 3AB-1S Feeder 2555S 3

11-28-79 E

No Battery Charger 3AB-2S Feeder 2560S 3

9-82 E

No 125V DC Battery Charger 3A1-S and 3A2-S 2561S 4

9-82 E

No 125V DC Battery Charger 3AB-S and 3AB2-S 2562S 3

9-92 E

No 125V DC Battery Charger 3B1-S and 3B2-S 2563S 13 9-82 E

No 125V DC Buses Instrumentation 2564S 4

9-18-80 E

No Static Uninterrupt Pwr Supp 3MA-S N Feeeder 2565S 4

9-18-80 E

No Static uninterrupt Pwr Supp 3MB-S N Feeder 2566S 4

9-18-80 E

No Static Uninterrupt Pwr Supp 3MC-S N Feeder 2567S 4

9-18-80 E

No Static Uninterrupt Pwr Supp 3ND-S N Feeder 2568S 3

11-28-79 E

No Static Uninterrupt Pwr Supp 3A-S N Feeder 2569S 3

11-28-79 E

No Static Uninterrupt Pwr Supp 3B-S N Feeder 2570S 7

9-82 E

No Static Uninterrupt Pwr Supp 3MA-S and 3MB-S 2571S 7

8-82 E

No Static Uninterrupt Pwr Supp 3MC-S and 3MD-S 2573S 4

8-6-80 E

No Static Uninterrupt Pwr Supp 3A-S and 3B-S 2575S 4

9-18-80 E

No Static Uninterrupt Pwr Supp 3KA-S Alt Feeder 2576S 4

9-18-90 E

No Static Uninterrupt Pwr Supp 3MB-S Alt Feeder 2577S 4

9-18-80 E

No Static Uninterrupt Pwr Supp 3MC-S Alt Feeder 2578S 4

9-18-80 E

No Static Uninterrupt Pwr Supp 3ND-S Alt Feeder 2583S 3

11-28-79 E

No Static Uninterrupt Pwr Supp 3A-S Alt Feeder 2584S 3

9-82 E

No Static Uninterrupt Pwr Supp 3B-S Alt Feeder 2596S 2

9-82 E

No Radiation Monitoring Safety Loop "A" 2597S 0

9-82 E

No Radiation Monitors Safety Ch. A Annunciation 2598S 2

9-82 E

No Radiation Monitoring Safety Loop "B" 2599S 0

9-82 E

No Radiation Monitors Safety Ch. B Annunciation

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 35 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 2635S 0

9-82 E

No Containment Atmosphere High Range Rad. Monitor A 2636S 0

9-82 E

No Containment Atmosphere High Range Rad. Monitor B 2656S 3

9-82 E

No Component Cooling Water Process Radiation Monitor "A" 2657S 3

9-82 E

No Component Cooling Water Process Radiation Monitor "B" 2660S 4

9-82 E

No Containment Purge Isolation "A" Area Radiation Monitor 2661S 6

9-82 E

No Containment Purge Isolation "B" Area Radiation Monitor 2662S 4

9-82 E

No Containment Purge Isolation "A" Area Radiation Monitor 2663S 4

9-82 E

No Containment Purge Isolation "B" Area Radiation Monitor 2666S 2

9-82 E

No Shield Building EL 46.0'-140º Post-LOCA Radiation Monitor "B" 2667S 2

9-82 E

No Shield Building EL 21.0'-230º Post-LOCA Radiation Monitor "B" 2668S 2

9-82 E

No Shield Building EL 21.0-140º Post-LOCA Radiation Monitor "A" 2669S 2

9-82 E

No Shield Building EL 46.0'-240º Post-LOCA Radiation Monitor "A" 2670S 3

9-82 E

No Containment Atmosphere Airborne Radiation Monitor 2671S 6

9-82 E

No Plant Stack Airborne Radiation Monitor "A" 2672S 6

9-82 E

No Plant Stack Airborne Radiation Monitor "B" 2673S 6

9-82 E

No Containment Atmosphere Radiation Monitor Isol. Valves 2675S 5

9-82 E

No Control Room Isolation "A" Airborne Radiation Monitor 2679S 1

10-23-80 E

No Control Room Isolation "B" Airborne Radiation Monitor 2681S 2

9-82 E

No Control Room Isolation "B" Airborne Radiation Monitor 2685S 3

9-82 E

No F/H Building Isolation "A" Airborne Radiation Monitor 2686S 2

9-82 E

No F/H Building Isolation "A" Airborne Radiation Monitor 2687S 2

9-82 E

No F/H Building Isolation "B" Airborne Radiation Monitor 2688S 3

9-82 E

No F/H Building Isolation "B" Airborne Radiation Monitor 2694S 3

9-82 E

No RPS Trip Alarms SH. 1 2695S 2

9-82 E

No RPS Trip Alarms SH. 2 2696S 2

9-82 E

No RPS Trip Alarms SH. 3 2697S 3

9-82 E

No RPS Pretrip Alarms SH. 1 2698S 3

9-82 E

No RPS Pretrip Alarms SH. 2 2699S 3

9-82 E

No RPS Pretrip Alarms SH. 3 2700S 2

8-1-79 E

No CP-10 External Connections SH1 2701S 3

8-1-79 E

No CP-10 External Connections SH2 2702S 3

8-1-79 E

No CP-10 External Connections SH3 2703S 3

8-1-79 E

No CP-10 External Connections SH4 2704S 2

9-7-79 E

No CP-10 External Connections SH5 2705S 3

9-82 E

No CP-10 External Connections SH6 2706S 2

9-7-79 E

No CP-10 External Connections SH7 2707S 2

9-7-79 E

No CP-10 External Connections SH8 2708S 4

9-82 E

No CP-10 External Connections SH9

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 36 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 2709S 4

9-82 E

No CP-10 External Connections SH10 2710S 2

9-7-79 E

No CP-10 External Connections SH11 2711S 2

9-7-79 E

No CP-10 External Connections SH12 2712S 4

9-82 E

No CP-10 External Connections SH13 2713S 5

9-82 E

No CP-10 External Connections SH14 2714S 5

9-82 E

No CP-10 External Connections SH15 2716S 3

9-82 E

No CP-10 External Connections SH17 2717S 3

9-82 E

No CP-10 External Connections SH18 2718S 3

9-92 E

No CP-10 External Connections SH19 2719S 3

9-82 E

No CP-10 External Connections SH20 2720S 3

9-82 E

No CP-10 External Connections SH21 2721S 3

11-17-78 E

No CP-10 External Connections SH22 2722S 3

11-17-78 E

No CP-10 External Connections SH23 2723S 3

11-17-78 E

No CP-10 External Connections SH24 2724S 5

9-82 E

No Plant Protection System Renote Control Module SH1 2725S 3

9-7-79 E

No Plant Protection System Remote Control Module SH2 2726S 4

9-82 E

No Plant Protection System Renote Control Module SH3 2727S 3

9-7-79 E

No Plant Protection System Remote Control Module SH4 2934S 1

9-82 E

No Annunciator Display Cabinets SA &SB 2935S 6

9-82 E

No Annunciator Logic Panel Safety Channel A and B 2951S 0

9-82 E

No Reactor Coolant Flow Monitor SH. 1 2952S 0

9-82 E

No Reactor Coolant Flow Monitor SH. 2 2954S 0

9-82 E

No Reactor Coolant Level Monitor No. 1 SH. 1 2955S 0

9-82 E

No Reactor Coolant Level Monitor No. 1 SH. 2 2956S 0

9-82 E

No Reactor Coolant Level Monitor No. 2 SH. 1 2957S 0

9-82 E

No Reactor Coolant Level Monitor No. 2 SH. 2 2961S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 1 2962S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 2 2963S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 3 2964S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 4 2965S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 5 2966S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 6 2967S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 7 2968S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 8 2969S 0

9-82 E

No QSPDS Miscellaneous Inputs SH. 9 3001S 1

9-82 E

No ESFAS Test Module Channel A SH. 1 3002S 1

9-82 E

No ESFAS Test Module Channel A SH. 2 3003S 1

9-82 E

No ESFAS Test Module Channel A SH. 3 3004S 1

9-82 E

No ESFAS Test Module Channel A SH. 4

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 37 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams-Safety Related (Cont'd)

B-424 3005S 1

9-82 E

No ESFAS Test Module Channel A SH. 5 3006S 1

9-82 E

No ESFAS Test Module Channel A SH. 6 3007S 1

9-82 E

No ESFAS Test Module Channel A SH. 7 3008S 1

9-82 E

No ESFAS Test Module Channel A SH. 8 3009S 1

9-82 E

No ESFAS Test Module Channel A SH. 9 3010S 1

9-82 E

No ESFAS Test Module Channel A SH. 10 3011S 1

9-82 E

No ESFAS Test Module Channel A SH. 11 3012S 1

9-82 E

No ESFAS Test Module Channel A sH. 12 3013S 1

9-82 E

No ESFAS Test Module Channel A SH. 13 3014S 1

9-82 E

No ESFAS Test Module Channel A SH. 14 3015S 1

9-82 E

No ESFAS Test Module Channel A SH. 15 3016S 1

9-82 E

No ESFAS Test Module Channel A SH. 16 3017S 1

9-82 E

No ESFAS Test Module Channel A SH. 17 3018S 1

9-82 E

No ESFAS Test Module Channel A SH. 18 3019S 1

9-82 E

No ESFAS Test Module Channel A SH. 19 3031S 1

9-82 E

No ESFAS Test Module Channel B SH. 1 3032S 1

9-82 E

No ESFAS Test Module Channel B SH. 2 3033S 1

9-82 E

No ESFAS Test Module Channel B SH. 3 3034S 1

9-82 E

No ESFAS Test Module Channel B SH. 4 3035S 1

9-82 E

No ESFAS Test Module Channel B SH. 5 3036S 1

9-82 E

No ESFAS Test Module Channel B SH. 6 3037S 1

9-82 E

No ESFAS Test Module Channel B SH. 7 3038S 1

9-82 E

No ESFAS Test Module Channel B SH. 8 3039S 1

9-82 E

No ESFAS Test Module Channel B SH. 9 3040S 1

9-82 E

No ESFAS Test Module Channel B SH. 10 3041S 1

9-82 E

No ESFAS Test Module Channel B SH. 11 3042S 1

9-82 E

No ESFAS Test Module Channel B SH. 12 3043S 1

9-82 E

No ESFAS Test Module Channel B SH. 13 3044S 1

9-82 E

No ESFAS Test Module Channel B SH. 14 3045S 1

9-82 E

No ESFAS Test Module Channel B SH. 15 3046S 1

9-82 E

No ESFAS Test Module Channel B SH. 16 3047S 1

9-82 E

No ESFAS Test Module Channel B SH. 17 3048S 1

9-82 E

No ESFAS Test Module Channel B SH. 18 3049S 1

9-82 E

No ESFAS Test Module Channel B SH. 19 (C) Control Wiring Diagrams - Non-Safety Related 117 5

9-82 E

No Excore Neutron Flux Control Channel #1 and Startup Channel #1 118 5

9-82 E

No Excore Neutron Flux Control Channel #2 and Startup Channel #2

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 38 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Non-Safety Related (Cont'd) 190 6

9-82 E

No Control Board Mounted Nuclear Instrumentation H4 192 3

9-82 E

No Control Board Miscellaneous Instrumentation SH1 274 8

9-82 E

No Pressurizer Level SH2 330 5

1-9-80 E

No Boric Acid Batching Tank Heater 990 6

9-82 E

No Instrument Air Compressor A 993 7

9-82 E

No Instrument Air Compressor B Alarms & Computer Inputs 995 7

9-82 E

No Instrument Air Dryer 755 0

E No ACCW Jockey Pump A 805 0

E No ACCW Jockey Pump B 1029 10 9-82 E

No Reactor Cavity Cool Syst. Fan S-2(3B) 1105 6

9-82 E

No RAB Normal Exhaust Fan E-22(3A) 1228 7

9-82 E

No FHB Vent System Air Handling Unit AH-14(3) 1230 7

9-82 E

No FHB Vent System Exh. Fan E-20(3A) 1231 7

9-82 E

No FHB Vent System Exh. Fan E-20(3B) 1249 4

9-82 E

No Cable Vault Area Dampers 1750 5

11-28-79 E

No Turbine Trip SH 1 1751 4

11-28-79 E

No Turbine Trip SH 2 1752 9

9-82 E

No Turbine Trip SH 3 1753 5

9-82 E

No Turbine Trip SH 4 1754 8

9-82 E

No Turbine Trip SH 5 1755 5

9-82 E

No Turbine Trip SH 6 1756 1

1-23-79 E

No Auto Stop Reset & Vacuum Trip Latch 1757 5

9-7-79 E

No Turbine Trip Alarms & Computer Inputs SH1 1758 11 9-82 E

No Turbine Trip Alarms & Computer Inputs SH2 2103 4

2-15-80 E

No Exitation System Annunciation 2151 7

9-82 E

No Generator Metering Current SH1 2152 2

9-10-79 E

No Generator Metering Current SH2 2155 3

3-28-80 E

No Generator Potential Tranof Circuits 2156 3

4-5-79 E

No Generator Metering Potential Circuits 2161 3

3-28-80 E

No Generator Diff. & Ground Relaying 2165 1

7-5-78 E

No Gen.-Main Transf. Diff. Relay SH1 2166 1

7-5-78 E

No Gen.-Main Transf. Diff. SH2 2168 2

8-1-79 E

No Main Transformer Gen. Breaker Diff. Relay 2184 1

7-25-78 E

No Main Transf. 3A Differential Relay 2189 1

6-29-78 E

No Main Transf. 3B Differential Relay 2194 1

6-29-78 E

No Unit Aux Transf. 3A Differential Relay 2199 1

6-29-78 E

No Unit Aux Transf. 3B Differential Relay 2201 7

9-82 E

No Generator Lockout Relay 86G1 Sheet 1 2202 8

9-82 E

No Generator Lockout Relay 86G1 Sheet 2

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 39 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Non-Safety Related (Cont'd) 2203 8

9-82 E

No Generator Lockout Relay 86G1 Sheet 3 2205 8

9-82 E

No Generator Lockout Relay 86G2 Sheet 1 2206 4

9-10-79 E

No Generator Lockout Relay 86G2 Sheet 2 2207 6

9-82 E

No Generator Lockout Relay 86G2 Sheet 3 2209 6

9-82 E

No Distance Lockout Relay 2210 8

9-82 E

No Synchronizing SH1 2211 3

9-82 E

No Synchronizing SH2 2221 2

9-82 E

No Generator Circuit Breaker 3A SH1 2222 3

9-82 E

No Generator Circuit Breaker 3A SH2 2225 2

9-82 E

No Generator Circuit Breaker 3B SH1 2226 2

9-82 E

No Generator Circuit Breaker 3B SH2 2231 5

9-10-79 E

No Aux. Transf. 3A to Bus 3A1 Breaker 2233 9

9-82 E

No Aux. Transf. 3A to Bus 3A2 Breaker 2235 6

9-82 E

No Aux. Transf. 3B to Bus 3B1 Breaker 2237 6

8-18-80 E

No Aux. Tranef. 3B to Bus 3B2 Breaker 2238 2

12-22-78 E

No 4 kV/7kV Transfer Failure Alarm 2240 3

9-82 E

No Standby Transf. 3A Disconnect SW 2244 1

4-12-78 E

No Standby Transf. 3A Diff Relays 2245 6

9-82 E

No Standby Transf. 3A Lockout Relay 2246 10 9-82 E

No Standby Transf. 3A to Bus 3A1 Breaker 2248 12 9-82 E

No Control Room North Wall Area Radiation Monitor 2601 2

9-82 E

No HVAC Floor EL 46.0' Radiation Monitor 2602 2

9-82 E

No Reactor Aux Bldg EL 21.0' Area Radiation Monitor 2603 2

9-82 E

No Reactor Aux Bldg EL-4.0' Area Radiation Monitor 2604 2

9-82 E

No Reactor Aux Bldg. EL-4.0' Area Radiation Monitor 2605 2

9-82 E

No Counting Room Area Radiation monitor 2606 2

9-82 E

No Sample Room Ares Radiation Monitor 2607 2

9-82 E

No Boric Acid Preconcentrators Filter Area Radiation Monitor 2608 2

9-82 E

No Waste Filter Wall Area Radiation Monitor 2609 2

9-82 E

No Druming Station Ares Radiation Monitor 2610 2

9-82 E

No Charging Pumps Wall Area Radiation Monitor 2611 2

9-82 E

No Reactor Aux. Bldg. Elevator Shaft Area Radiation Monitor

(DRN 01-758, R11-A) 2612 2

9-82 E

No Radio Chemistry Lab Area Radiation lionitor

(DRN 01-758, R11-A) 2613 2

9-82 E

No Reactor Aux. Bldg Valve Gallery Area Radiation Monitor 2614 2

9-82 E

No Reactor Aux. Bldg. Filter Flush Area Radiation Monitor 2615 2

9-82 E

No Standby Transf. 3A to Bus 3A2 Breaker 2250 4

9-82 E

No Standby Transf. 3B Disconnect SW

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 40 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Non-Safety Related (Cont'd) 2254 1

7-5-78 E

No Standby Transf. 3B Diff Relays 2255 7

9-82 E

No Standby Transf. 3B Lockout Relay 2256 9

9-82 E

No Standby Transf. 3B to 3B1 Breaker 2258 11 9-82 E

No Standby Transf. 3B to Bus 3B2 Breaker 2260 4

6-6-79 E

No Main & Standby Transf 3A & 3B Ground Protection 2325 7

9-82 E

No Diesel Gen A Computer Inputs SH1 2331 4

9-82 E

No 4.16 kV Bus 3A2 Tie to Bus 3A3-S 2380 2

2-4-80 E

No Diesel Gen B Local Annunciator Front View 2381 6

9-82 E

No 4.16 kV Bus 382 Tie to Bus 3B3-S 2590 3

9-82 E

No Radiation Monitor NIS Loop "A" 2592 2

9-82 E

No Radiation Monitor NIS Loop "B" 2594 3

9-82 E

No Radiation Monitor N/S Loop "C" 2600 2

9-82 E

No RAB Waste Gas Coup Area Radiation Monitor 2616 2

9-82 E

No RAB EL-35.0' Area Radiation Monitor 2617 2

9-82 E

No RAB EL-4.0' Area Radiation Monitor 2618 2

9-82 E

No Decontamination Room Area Radiation Monitor 2619 2

9-82 E

No Gas Decay Tanks Area Radiation Monitor 2625 2

9-82 E

No Spent Fuel Storage Pool Area Radiation Monitor 2626 2

9-82 E

No New Fuel Vault Area Radiation Monitor 2627 2

9-82 E

No Fuel Pool Pumps Area Radiation Monitor 2630 3

9-82 E

No Refueling Machine Area Radiation Monitor 2631 3

9-82 E

No Containment Southwest Staircase Area Radiation Monitor 2632 3

9-82 E

No Containment Northeast Staircase Area Radiation Monitor 2633 3

9-82 E

No Personnel Lock Annulus Area Radiation Monitor 2640 3

9-82 E

No Fuel Handling Exhaust A Radiation Monitor 2641 3

9-82 E

No Fuel Handling Exhaust B Radiation Monitor 2642 3

9-82 E

No RAB Airborne Radiation Monitor A 2643 3

9-82 E

No RAB Airborne Radiation Monitor B 2644 3

9-82 E

No RAB Airborne Radiation Monitor C 2645 3

9-82 E

No RAB Airborne Radiation Monitor D 2650 2

9-82 E

No Condenser Vacuum Pumps Process Radiation Monitor 2651 2

9-82 E

No Dry Cooling Tower Sump #1 Process Radiation Monitor 2652 2

9-82 E

No Dry Cooling Tower Sump #2 Process Radiation Monitor 2653 2

9-82 E

No Reactor Bldg Sump Process Radiation Monitor 2654 2

9-82 E

No Industrial Waste Sump Process Radiation Monitor 2655 2

9-82 E

No Circulating Water Discharge Process Radiation Monitor 2658 1

9-82 E

No Component Cooling Water Process Radiation Monitor A/B 2852 3

1-9-80 E

No Computer Inputs SH.53

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 41 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Non-Safety Related (Cont'd)

B-424 2922 1

9-82 E

No Annunciator Display Cabinet A 2923 2

9-82 E

No Annunciator Display Cabinet B 2924 2

9-82 E

No Annunciator Display Cabinet C 2925 2

9-82 E

No Annunciator Display Cabinet D 2926 3

9-82 E

No Annunciator Display Cabinet E 2927 2

9-82 E

No Annunciator Display Cabinet F 2928 2

9-82 E

No Annunciator Display Cabinet G 2929 1

9-82 E

No Annunciator Display Cabinet H 2930 1

9-82 E

No Annunciator Display Cabinet K 2931 2

9-82 E

No Annunciator Display Cabinet L 2932 2

9-82 E

No Annunciator Display Cabinet M 2933 2

9-82 E

No Annunciator Display Cabinet N G246 S01 7

4-82 E

No Reactor Containment Building Sect. and Details S02 3

9-78 E

No Reactor Containment Building Sect. and Details S03 1

9-78 E

No Reactor Containment Building Sect. and Details S04 0

4-80 E

No Reactor Containment Building Sect. and Details G322 S01 7

12-78 E

No Cable Vault and Elec. Equip Room Sect. and Details S02 7

11-79 E

No Cable Vault and Elec. Equip Room Sect. and Details S03 4

12-78 E

No Cable Vault and Elec. Equip Room Sect. and Details S04 4

12-78 E

No Cable Vault and Elec. Equip Room Sect. and Details S05 2

05-80 E

No Cable Vault and Elec. Equip Room Sect. and Details S06 2

12-79 E

No Cable Vault and Elec. Equip Room Sect. and Details S07 2

12-79 E

No Cable Vault and Elec. Equip Room Sect. and Details S08 3

05-80 E

No Cable Vault and Elec. Equip Room Sect. and Details

(DRN 01-758, R11-A)

S09 2

06-82 E

No Cable Vault and Elec. Equip Room Sect. and Details

(DRN 01-758, R11-A)

S10 0

04-80 E

No Cable Vault and Elec. Equip Room Sect. and Details G285 3

12-78 E

No Main One Line Diagram G286 3

7-12-78 E

No Key Auxiliary One Line Diagram G287 2

11-30-78 E

No 125V DC & 120V AC One Line Diagram

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 42 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Non-Safety Related (Cont'd)

G310 S01 1

9-5-78 E

No Reactor Containment Building EL-4 Conduit, Trays and Grounding S02 2

9-5-78 E

No Reactor Containment Building EL-4 Conduit, Trays and Grounding S03 2

12-79 E

No Reactor Containment Building EL-4 Conduit, Trays and Grounding S04 2

06-79 E

No Reactor Containment Building EL-4 Conduit, Trays and Grounding G311 S01 7

06-79 E

No Reactor Containment Building EL+21 Conduit, Trays and Grounding S02 0

6-1-79 E

No Reactor Containment Building EL+21 Conduit, Trays and Grounding G312 6

6-26-79 E

No Reactor Containment Building EL+4 Conduit Trays and Grounding G313 7

6-79 E

No Electrical Penetration Area-Elevation & Details G314 7

10-80 E

No Reactor Containment Building-Sections & Details Sh1 G315 5

9-8-78 E

No Reactor Containment Building-Sections & Details SH2 B316 96 Sheets 4(a)

Open E

No Electrical Penetrations Details G317 S01 8

9-20-78 No Reactor Aux. Bldg. EL. +7.00 Conduit, Trays & Grounding SH1 G317 S02 10 05-82 E

No Reactor Aux. Bldg. EL. +7.00 Conduit, Trays & Grounding SH2 G318 9

05-82 E

No Control Room Arrangement, Conduit & Grounding G319 S01 8

6-14-79 E

No Cable Vault Conduit, Trays & Grounding SH1 G319 S02 8

6-14-79 E

No Cable Vault Conduit, Trays & Grounding SH2 G320 S01 7

11-29-78 E

No Electrical Equipment Room Arrangement - Grounding SH1 G320 S02 8

11-79 E

No Electrical Equipment Room Arrangement - Grounding SH2 G321 S0l 9

07-80 E

No Electrical Equipment Room - Conduit & Trays SH1 G321 S02 9

05-81 E

No Electrical Equipment Room - Conduit & Trays SH2 G322 S0l 7

12-29-78 E

No Cable Vault & Electrical Equipment Room Sections & Details - SH1 G322 S02 7

11-79 E

No Cable Vault & Electrical Equipment Room Grounding SH2 G322 S03 4

12-29-78 E

No Cable Vault & Electrical Equipment Room Section & Details SH3 G322 S04 4

12-29-78 E

No Cable Vault & Electrical Equipment Room Section & Details SH4 G322 S05 2

05-80 E

No Cable Vault & Electrical Equipment Room Section & Details SH5 Note: (a) Revision number is that of index.

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 43 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE (C) Control Wiring Diagrams - Non-Safety Related (Cont'd)

(DRN 01-758, R11-A)

G322 S06 2

12-79 E

No Cable Vault & Electrical Equipment Room Section & Details SH6

(DRN 01-758, R11-A)

G322 S07 2

12-79 E

No Cable Vault & Electrical Equipment Room Section & Details SH7 G322 S08 3

12-79 E

No Cable Vault & Electrical Equipment Room Section & Details SH8 G322 S09 1

10-9-78 E

No G240 S01 4

11-30-37 E

No RAB El +21 Conduit, Trays & Grounding SH1 G240 S02 5

6-14-79 E

No RAB El +21 Conduit, Trays & Grounding SH2 G241 S01 5

04-82 E

No RAB El +46 to +81 Conduit & Grounding SH1 G241 S02 3

10-4-78 E

No RAB El +46 to +81 Conduit & Grounding SH2 G242 S01 5

07-80 E

No H&V Room El +46 Conduit, Trays & Grounding SH1 G242 S02 5

04-82 E

No H&V Room El +46 Conduit, Trays & Grounding SH2 G324 7

12-19-78 E

No Reactor Auxiliary Building EL+21 Conduit, Trays & Grounding SH2 G327 7

11-30-78 E

No Reactor Auxiliary Building EL-4 Conduit, Trays & Grounding SH1 G328 7

11-30-78 E

No Reactor Auxiliary Building EL-4 Conduit, Trays & Grounding SH2 G329 6

11-30-78 E

No Reactor Auxiliary Building EL-4 Conduit, Trays & Grounding SH4 G330 8

05-80 E

No Reactor Auxiliary Building EL-4 Conduit, Trays & Grounding SH3 G331 10 04-80 E

No Electrical Penetration Area Conduit, Trays & Grounding SH3 G332 to 6-27-79 E

No Electrical Penetration Area Conduit, Trays & Grounding SH2 G333 9

6-14-79 E

No Reactor Auxiliary Building EL-35 Conduit, Trays & Grounding SH1 G334 9

11-79 E

No Reactor Auxiliary Building EL-35 Conduit, Trays & Grounding SH2 G335 S01 9

6-26-79 E

No Reactor Auxiliary Building EL-35 Conduit, Trays & Grounding SH3 G336 9

6-26-79 E

No Reactor Auxiliary Building EL-35 Conduit, Trays & Grounding SH4 G337 8

12-28-79 E

No Reactor Auxiliary Building Piping Penetration Area Conduit, Trays & Grounding SH1 G338 9

04-80 E

No Reactor Auxiliary Building Piping Penetration Area Conduit, Trays & Grounding SH2 G339S01 5

6-15-77 E

No Reactor Auxiliary Building Sections & Details SH1 G339S02 3

11-30-78 E

No Reactor Auxiliary Building Sections & Details SH2 G342 8

6-14-79 E

No Fuel Handling Building EL 1 & -35 Conduit, Trays &

Grounding G343 8

05-82 E

No Fuel Handling Building EL+21 & 46 Conduit, Trays &

Grounding

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 44 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING SHEET REVISION PREPARED PROPRIETARY NO.

NO.

NO.

DATE BY INFO.

TITLE G344 S01 5

9-14-78 E

No Electrical Equipment Room Switchgear, MCC & Panel Details - SH1 S02 5

04-82 E

No Electrical Equipment Room Switchgear, MCC & Panel Details - SH2 S03 3

9-14-78 E

No Electrical Equipment Room Switchgear, MCC & Panel Details - SH3 G373S01 8

11-30-78 E

No Cooling Tower Area - Conduit & Grounding-SH1 S02 7

11-30-78 E

No Cooling Tower Area - Conduit & Grounding-SH2 S03 6

11-30-78 S04 0

06-81 E

No Met Towers - Grdg., Ltg. & Details G374 4

11-30-78 E

No Cooling Tower Area - Sections & Details G376SO1 5

3-15-78 E

No Reactor Auxiliary Building Embedded Conduits Below EL(-35) SH1 S02 4

9-30-77 E

No Reactor Auxiliary Building Embedded Conduits Below EL(-35) SH2 S03 4

9-30-77 E

No Reactor Auxiliary Building Embedded Conduits Below EL(-35) SH3 S04 5

3-15-78 E

No Reactor Auxiliary Building Embedded Conduits Below EL(-35) SH4 G377SO1 3

09-77 E

No Seismic Cable Supports Piping Penetration Area

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 45 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING & REVISION NUMBER REVISION PREPARED PROPRIETARY TITLE EBASCO OTHERS DATE BY INFO.

203 R3 B-9270-413-101 3

7/13/77 CE No MCBD Temp. Channel 204 3

B-9270-413-102 3

7/13/77 CE No MCBD Temp. Channel 207 3

B-9270-413-105 3

5/30/73 CE No MCBD Press. Pressure Channel 164 4

B-9270-413-107 3

CE No MCBD Press. Pressure Channel 166 3

B-9270-413-109 SH1 3

7/13/77 CE No MCBD Press. & Level Channel 170 4

B-9270-413-201 4

7/13/77 CE No MCBD CVCS Temp. Channel 174 3

B-9270-413-205 3

7/13/77 CE No MCHD CVCS Level Channel 175 2

B-9270-413-207 1

CE No MCBD CVCS Press. Channel 177 4

B-9270-413-209 3

CE No MCBD CVCS Press. Channel 179 3

B-9270-413-301 3

7/13/77 CE No MCBD CVCS SIS Press. & Level Chan-180 4

B-9270-413-302 3

CE No MCBD CVCS SIS Press. & Level Chan-181 3

B-9270-413-303 3

7/13/77 CE No MCBD CVCS SIS Press. & Level Chan-182 4

B-9270-413-304 3

7/13/77 CE No MCBD CVCS SIS Press. & Level Chan-X B-9270-413-304 4

CE No MCBD SIS Flow & Temp. Channel 184 4

B-9270-413-306 4

7/13/77 CE No MCBD SIS Press. & Temp. Chan.

200 4

B-9270-413-401 3

7/13/77 CE No MCBD Stm. Gen. Press & Level Chan.

201 4

B-9270-413-402 3

7/13/77 CE No MCBD Stm. Gen. Press & Level Chan.

718 2

B-9270-413-112 SH1 3

7/13/77 CE No MCBD Rcp Measurement Channel 719 2

SH2 1

7/13/77 720 3

B-9270-413-113 2

4/17/76 721 3

B-9270-413-114 3

7/13/77 CE No MCBD RCP Measurement Channel 751 2

B-9270-413-116 2

7/13/77 CE No MCBD Board Mounted Nuclear Instrumentation SH 1 752 1

B-9270-413-116 1

4/17/76 CE No MCBD Board Mounted Nuclear Instrumentation SH 2

(DRN 01-758, R11-A) 185 4

B-9270-413-308 3

CE No MCBD RWP Level Channel

(DRN 01-758, R11-A) 1635 1

D-ICE-411-581 2

5/20/75 CE No Excore Instr-Cabling Diag.

7460 0

E-9270-411-501 1

6/30/77 CE No PPS Functional Diagram SH.1 648 3

E-ICE411-501 1

4/6/76 CE No PPS Functional Diagram SH.2 649 3

E-ICE-411-501 6

7/21/75 CE No PPS Functional Diagram SH.3 8643 0

E-9720-411-503 1

10/7/77 CE No PPS Interface Logic Diagram 663 4

E-ICE-411-520 6

3/29/77 CE No PPS Cab. Assy. & Frt Panel 1/0 SH1 664 4

E-ICE-411-520 4

3/29/77 CE No PPS Cab. Assy. & Frt Panel 1/0 SH2 665 4

E-ICE-411-520 4

3/29/77 CE No PPS Cab. Assy. & Frt Panel 1/0 SH3 7464 0

E-9270-411-521 1

6/30/77 CE No PPS Rmt Control Module 1/0 X

J-ICE-411-522 E1 CE No PPS Status - Frt Panel 1/0

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 46 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING & REVISION NUMBER REVISION PREPARED PROPRIETARY TITLE EBASCO OTHERS DATE BY INFO.

667 4

E-ICE-411-531 6

4/78 CE No PPS 2/4 Logic Matrix Sch SH1 668 4

E-ICE-411-531 6

4/78 CE No PPS 2/4 Logic Matrix Sch SH2 669 4

E-ICE-411-531 6

4/78 CE No PPS 2/4 Logic Matrix Sch SH3 670 4

E-ICE-411-531 6

4/78 CE No PPS 2/4 Logic Matrix Sch SH4 671 4

E-ICE-411-531 6

4/78 CE No PPS 2/4 Logic Matrix Sch SH5 672 4

E-ICE-411-531 6

4/78 CE No PPS 2/4 Logic Matrix Sch SH6 7461 0

E-9270-411-532 1

6/30/77 CE No PPS Testing Sys Sch 656 6

E-ICE-411-534 2

4/78 CE No PPS Trip Path Sch 659 5

E-ICE-411-550 4

4/78 CE No PPS Calib & Test Panel Sch 7462 0

E-9270-411-560 1

6/30/77 CE No PPS Bypass & Block Sch 652 3

E-ICE-411-562 4

8/6/75 CE No PPS Misc Sch 7459 0

E-9270-411-570 1

6/30/77 CE No PPS Annum Input Sch Sh 1 646 3

E-9270-411-570 4

7/22/75 CE No PPS Annun Input Sch Sh 2 955 4

E-9270-413-130 E2 CE No Reactor Trip Swgear Arrgmt 1870 1

E-ICE-411-501 3

8/1/75 CE No PPS Functional Diagram Sh 4 1871 2

D-ICE-411-504 3

12/9/76 CE No ESFAS 1875 2

E-ICE-411-537 4

CE No PPS Variable Setpoint Sch 734 2

E-ICE-411-561 3

7/29/74 CE No PPS Aux Logic Sch 1872 1

0-ICE-411-533 2

7/9/75 CE No PPS CPC Test Panel Sch 1873 1

0-ICE-411-533 1

7/9/75 CE No PPS CPC Test Panel Sch 2557 1

B-9270-416-002 1

12/19/76 CE No Swch. Development Sh 1-4 3075 1

B-9270-416-003 1

12/13/76 CE No Power Dist to Instr Cab 1972 1

B-9270-416-007 1

12/13/76 CE No Wide Range Press Press Channel 1977 1

B-9270-416-008 1

12/13/76 CE No Steam Gen. Press Chan 1976 2

B-9270-416-009 SH1 2

CE No Steam Gen. Level Chan SH2 1

SH3 1

SH4 1

1967 2

B-9270-416-010 2

CE No 1978 2

B-9270-416-011 3

7/29/77 CE No RWT Level Chan 1968 1

B-9270-416-012 1

12/13/76 CE No RCP Protective Speed Chan 1969 2

B-9270-416-013 2

CE No Press Press Channel 1970 1

B-9270-416-014 1

12/13/76 CE No Shutdown Heat Exch. 1/0 Temp Chan 8537 0

E-9720-414-075 1

9/23/77 CE No S/D Cooling Temp Channel 653 2

E-9270-411-580 2

CE No CPS Sys Ext Cabling Diagram 654 6

E-9270-411-580 2

CE No PPS Cont Rm Cabling Diagram 1871 2

D-ICE-411-504 3

CE No PPS Cont Rm Cabling Diagram 7553 1

F12004/E30/3ASA 1

CE No ESFAS 6179 0

E-9270-413-021 0

3/31/77 CE No General Layout for E-30 (3A-SA)

Steam Bypass Control System

(DRN 04-1444, R13-B)

End of historical information.

(DRN 04-1444, R13-B)

(DRN 02-85, R11-A; 04-1444, R13-B)

Start of historical information.

(DRN 04-1444, R13-B)

WSES-FSAR-UNIT 3

(DRN 02-85, R11-A)

TABLE 1.7-1 (Sheet 47 of 47)

Revision 13-B (01/05)

ELECTRICAL, INSTRUMENTATION AND CONTROL DRAWINGS DRAWING & REVISION NUMBER REVISION PREPARED PROPRIETARY TITLE EBASCO OTHERS DATE BY INFO.

5061 103-524312 Open SEL Block Diagram 5059 142-100067 Open SEL System Layout - Core Protection System (5 Shts.)

Interconnection Diagram - Core Protection 5062 144-100555 Open SEL Calculator System (2 Shts.)

Cable Assembly - External Operators 5063 144-100556 Open SEL Module Signal (5 Shts.)

5064 149-100316 Open SEL Cable Assembly - External CRT Signal 5066 149-100317 Open SEL CPC "A" Analog Inputs (19 Shts,)

CPC "B" Analog Inputs (20 ShLs.)

5067 149-100318 Open SEL CPC "C" Analog Inputs 5068 149-100319 Open SEL CPC "D" Analog Inputs (19 Shts.)

5069 149-100320 Open SEL CEAC "1" Analog Inputs (16 Shts.)

5070 149-100321 Open SEL CEAC "2" Analog Inputs