ML16256A481
ML16256A481 | |
Person / Time | |
---|---|
Site: | Waterford ![]() |
Issue date: | 08/25/2016 |
From: | Entergy Operations |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML16256A115 | List:
|
References | |
W3F1-2016-0053 | |
Download: ML16256A481 (10) | |
Text
WSES-FSAR-UNIT-3 10-i CHAPTER 10 STEAM AND POWER CONVERSION SYSTEM TABLE OF CONTENTS
Section Title Page
10.0 STEAM AND POWER CONVERSION SYSTEM 10.1-1
10.1
SUMMARY
DESCRIPTION 10.1-1
10.2 TURBINE GENERATOR 10.2-1
10.2.1 DESIGN BASES 10.2-1
10.
2.2 DESCRIPTION
10.2-1
10.2.3 TURBINE DISK INTEGRITY 10.2-7
10.2.4 EVALUATION 10.2-15
10.2 REFERENCES
10.2-15
10.3 MAIN STEAM SUPPLY SYSTEM 10.3-1
10.3.1 DESIGN BASES 10.3-1
10.
3.2 DESCRIPTION
10.3-2
10.3.3 EVALUATION 10.3-4
10.3.4 INSPECTION AND TESTING REQUIREMENTS 10.3-5
10.3.5 WATER CHEMISTRY 10.3-5
10.3.6 STEAM AND FEEDWATER SYSTEM 10.3-8
10.3 REFERENCES
10.3-9
10.4 OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM 10.4-1
10.4.1 MAIN CONDENSER 10.4-1
10.4.2 MAIN CONDENSER EVACUATION SYSTEM 10.4-4
10.4.3 TURBINE GLAND SEALING SYSTEM 10.4-6
10.4.4 STEAM BYPASS SYSTEM 10.4-7
WSES-FSAR-UNIT-3 10-ii CHAPTER 10 STEAM AND POWER CONVERSION SYSTEM TABLE OF CONTENTS (Cont'd)
Section Title Page
10.4.5 CIRCULATING WATER SYSTEM 10.4-9
10.4.6 CONDENSATE CLEAN-UP SYSTEM 10.4-12
10.4.7 CONDENSATE AND FEEDWATER SYSTEMS 10.4-16
10.4.8 STEAM GENERATOR BLOWDOWN SYSTEM 10.4-22
10.4.9 EMERGENCY FEEDWATER SYSTEM 10.4-28
10.4.10 CHEMICAL FEED SYSTEM 10.4-36
10.4.9A EMERGENCY FEEDWATER SYSTEM RELIABILITY ANALYSIS 10.4.9B-i
WSES-FSAR-UNIT-3 10-iii Revision 11 (05/01)
CHAPTER 10 STEAM AND POWER CONVERSION SYSTEM LIST OF TABLES
Table Title
10.2-1 EXTRACTION STEAM VALVE ARRANGEMENTS FOR TURBINE OVERSPEED PROTECTION
10.2-2 TURBINE OVERSPEED PROTECTION DEVICES
10.2-3 LOW PRESSURE TURBINE MATERIALS
10.3-1 MAIN STEAM SUPPLY SYSTEM MAIN STEAM LINE SAFETY VALVES
10.3-2 STEAM GENERATOR BLOWDOWN CHEMISTRY LIMITS
10.3-3 FEEDWATER OPERATING CHEMISTRY LIMITS
10.3-4 DELETED
10.3-5 BRANCH CONNECTIONS BETWEEN MSIV'S AND TURBINE STOP VALVES
10.3-6 DELETED
10.3-7 DELETED
10.3-8 DELETED
10.3-9 DELETED
10.4-1 MAIN CONDENSER PERFORMANCE AND DATA
10.4-2 CIRCULATING WATER SYSTEM COMPONENT DATA
10.4-3 CONDENSATE PUMP DATA
10.4-4 HEATER DRAIN PUMP DATA
10.4-5 STEAM GENERATOR FEEDWATER PUMP DATA
10.4-5a AUXILIARY FEEDWATER PUMP DATA
10.4-6 FEEDWATER HEATER DATA
10.4-7 STEAM GENERATOR BLOWDOWN TANK AND PUMP DATA
10.4-8 STEAM GENERATOR BLOWDOWN HEAT EXCHANGERS DATA (DRN 99-2262, R11) 10.4-9 DELETED (DRN 99-2262, R11) 10.4-10 REGENERATIVE WASTE TANK PUMP AND PUMP DATA (DRN 99-2262, R11) 10.4-11 DEMINERALIZER COMPONENT DESIGN DATA (DRN 99-2262, R11)
WSES-FSAR-UNIT-3 10-iv CHAPTER 10 STEAM AND POWER CONVERSION SYSTEM LIST OF TABLES (Cont'd)
Table Title
10.4-11a BLOWDOWN BOOSTER PUMP
10.4-12 EMERGENCY FEEDWATER SYSTEM COMPONENT DESIGN DATA
10.4-13 CONDENSATE STORAGE POOL CHEMICAL COMPOSITION
10.4-14 EMERGENCY FEEDWATER SYSTEM FAILURE MODE AND EFFECTS ANALYSIS
10.4-15 EMERGENCY FEEDWATER SYSTEM INSTRUMENTATION APPLICATION
10.4-16 CONDENSATE DEMINERALIZER EFFLUENT WATER QUALITY
10.4-17 CONDENSATE CLEAN-UP DESIGN DATA
10.4.9A-1 EVALUATION OF THE WATERFORD SES UNIT NO. 3 EMERGENCY FEEDWATER SYSTEM VERSUS THE REQUIREMENTS OF STANDARD REVIEW PLAN (SRP) 10.4.9 AND BRANCH TECHNICAL POSITION (BTP) ASB 10-1
10.4.9A-2 EVALUATION OF THE WATERFORD SES UNIT NO. 3 EMERGENCY FEEDWATER SYSTEM VERSUS THE NRC EFW SHORT AND LONG TERM RECOMMENDATIONS
10.4.9A-3 COMPARISON OF WATERFORD EFW SYSTEM WITH NRC EFW SYSTEM FLOW REQUIREMENTS
10.4.9B-1 COMPONENT LIST MANUAL VALVES
10.4.9B-2 EFS FAILURE MODES AND EFFECTS ANALYSIS
10.4.9B-3 MINIMAL CUT SETS - CASE 1
10.4.9B-4 MINIMAL CUT SETS - CASE 2
10.4.9B-5 DELETED
10.4.9B-6 BASIC EVENT CAUSES AND PROBABILITIES
10.4.9B-7 EFS VALVES SUBJECT TO ASME SECTION XI TESTING
10.4.9B-8
SUMMARY
OF TEST AND MAINTENANCE CONTRIBUTIONS TO COMPONENT AVAILABILITY
10.4.9B-9 DOMINANT CUT SETS - CASE 1
10.4.9B-10 DOMINANT CUT SETS - CASE 2
10.4.9B-11 DOMINANT CUT SETS - CASE 3
WSES-FSAR-UNIT-3 10-v Revision 14 (12/05)
CHAPTER 10 (DRN 04-719, R14)
STEAM AND POWER CONVERSION SYSTEM (DRN 04-719, R14)
LIST OF FIGURES
Figure Title
10.2-1 STEAM PRESSURE VARIATION WITH POWER
10.2-2 HEAT BALANCE MAXIMUM GUARANTEED
10.2-3 HEAT BALANCE MAX CALCULATED (NOT GUARANTEED)
10.2-4 FLOW DIAGRAM MAIN & EXTRACTION STEAM SYSTEMS (SHEET 1 OF 4)
10.2-4 FLOW DIAGRAM MAIN & EXTRACTION STEAM SYSTEMS (SHEET 2 OF 4)
10.2-4 FLOW DIAGRAM MAIN & EXTRACTION STEAM SYSTEMS (SHEET 3 OF 4)
10.2-4 FLOW DIAGRAM MAIN & EXTRACTION STEAM SYSTEMS (SHEET 4 OF 4)
10.2-5 TURBINE OVERSPEED PROTECTION ELECTRO-HYDRAULIC SYSTEM
10.2-6 DIGITAL ELECTRO-HYDRAULIC (DEH) CONTROL SYSTEM
10.2-7 TURBINE HIGH-PRESSURE ELEMENT (DRN 04-719, R14) 10.2-8 DELETED (DRN 04-719, R14) 10.2-9 OVERSPEED PROTECTION CONTROLLER
10.3-1 MAIN STEAM ISOLATION VALVE
10.3-2 LOCATIONS OF PROCESS SAMPLE POINTS
10.4-1 FLOW DIAGRAM CIRCULATING, SERVICE & INTAKE COOLING WATER SYSTEMS (SHEET 1 OF 2) (DRN 01-420) 10.4-1 FLOW DIAGRAM CIRCULATING, SERVICE & INTAKE COOLING WATER SYSTEMS (SHEET 2 OF 2)
10.4-2 FLOW DIAGRAM-FEEDWATER CONDENSATE & AIR EVACUATION SYSTEM (SHEET 1 OF 6) (DRN 01-420) 10.4-2 FLOW DIAGRAM-FEEDWATER CONDENSATE & AIR EVACUATION SYSTEM (SHEET 2 OF 6)
10.4-2 FLOW DIAGRAM-FEEDWATER CONDENSATE & AIR EVACUATION SYSTEM (SHEET 3 OF 6)
10.4-2 FLOW DIAGRAM-FEEDWATER CONDENSATE & AIR EVACUATION SYSTEM (SHEET 4 OF 6)
WSES-FSAR-UNIT-3 10-vi Revision 12-C (07/03)
CHAPTER 10 TEAM AND POWER CONVERSION SYSTEM LIST OF FIGURES
Figure Title
10.4-2 FLOW DIAGRAM-FEEDWATER CONDENSATE & AIR EVACUATION SYSTEM (SHEET 5 OF 6)
10.4-2 FLOW DIAGRAM-FEEDWATER CONDENSATE & AIR EVACUATION SYSTEM (SHEET 6 OF 6)
(DRN 03-683, R12-C) 10.4-3 FLOW DIAGRAM TURBINE BUILDING MISCELLANEOUS SYSTEMS (SHEET 1 OF 2)
10.4-3 FLOW DIAGRAM TURBINE BUILDING MISCELLANEOUS SYSTEMS (SHEET 2 OF 2) (DRN 03-683, R12-C)
(DRN 01-420, R11) 10.4-4 FLOW DIAGRAM HEATER DRAIN & VENT SYSTEMS (SHEET 1 OF 4) (DRN 01-420, R11)
10.4-4 FLOW DIAGRAM HEATER DRAIN & VENT SYSTEMS (SHEET 2 OF 4)
10.4-4 FLOW DIAGRAM HEATER DRAIN & VENT SYSTEMS (SHEET 3 OF 4)
10.4-4 FLOW DIAGRAM HEATER DRAIN & VENT SYSTEMS (SHEET 4 OF 4)
10.4-5 FLOW DIAGRAM STEAM GENERATOR BLOWDOWN SYSTEM (SHEET 1 OF 2)
10.4-5 FLOW DIAGRAM STEAM GENERATOR BLOWDOWN SYSTEM (SHEET 2 OF 2)
10.4-6 EMERGENCY FEEDWATER SYSTEM
10.4-7 DELETED
10.4-8 BACKWASH TREATMENT SYSTEM FLOW DIAGRAM 10.4-9 CONDENSATE POLISHER SYSTEM FLOW DIAGRAM
10.4.9A-1 DELETED
10.4.9B-1 WSES-3 SIMPLIFIED EFS FLOW DIAGRAM (APPENDIX 10.4.9A)
10.4.9B-2 EFS FAULT TREE, CASE 1 - LMFW (APPENDIX 10.4.9A)
10.4.9B-3 EFS FAULT TREE, CASE 2 - LMFW/LOOP (APPENDIX 10.4.9A)
10.4.9B-4 EFS FAULT TREE, CASE 3 - LMFW/SB (APPENDIX 10.4.9A)
WSES-FSAR-UNIT-3 10-vii Revision 14 (12/05)
UPDATE REFERENCE LIST Chapter 10
Section Cross References
Revision 12-B
10.4.2.5 ER-W3-2002-0663-001/DRN 03-214
Revision 12-C
Figure 10.2-6 ER-W3-2001-0274-000/DRN 03-556
Figure 10.4-3 Sht 1 ER-W3-2003-0255-000/DRN 03-683 Figure 10.4-3 Sht 2
Revision 13
Section 10.4.7.3 ER-W3-2002-0288-002/DRN 03-1888
Section 10.3.1 ER-W3-2003-0755-001/DRN 03-2157 Section 10.4.1
Revision 13-A
Figure 10.2-6 Sht. 2 ER-W3-2003-0142-000/DRN 04-987 Figure 10.2-6 Sht. 3
Section 10.4.5.3 ER-W3-2004-0265-000/DRN 04-616
Revision 14
Section 10.3.1 ER-W3-2001-1149-000/DRN 03-2064 Section 10.3.3 Section 10.4.1.1 Section 10.4.1.2 Section 10.4.1.3 Section 10.4.2.2 Section 10.4.4.1 Section 10.4.4.2 Section 10.4.6.1 Section 10.4.7.1 Section 10.4.7.2 Section 10.4.8 Table 10.4-1 Table 10.4-6 Table 10.4-17 sh 1 Figure 10.2-1 Figure 10.2-2 Figure 10.2-3 sh 1
Table 10.4.9A-3 shts 2-3 ER-W3-2001-1149-000/DRN 05-544
WSES-FSAR-UNIT-3 10-viii Revision 15 (03/07)
UPDATE REFERENCE LIST Chapter 10
Section Cross References
Revision 14 Cont'd
Table Of Contents ER-W3-2003-0053-000/DRN 04-719 Section 10.2.1 Section 10.2.2.2.1 Section 10.2.3.1.1 Section 10.2.3.3 Section 10.2.3.5 Reference 10.2 Figure 10.2-7 Figure 10.2-8
Section 10.2.4 ER-W3-2003-0053-000/DRN 05-861
Table 10.4-1 ER-W3-2004-0007-000/DRN 04-1702
Section 10.4.9.1.a ER-W3-2004-0276-002/DRN 05-870
Section 10.4.7.3 ER-W3-2004-0602-000/DRN 05-235
Section 10.4.9.3.2 ER-W3-2004-0615-000/DRN 05-447
Section 10.4.8.2 ER-W3-2004-0618-000/DRN 05-151 Section 10.4.8.3
Section 10.4.6.2.1 ER-W3-2005-0126-000/DRN 05-565
Figure 10.2-4 sh 3 ER-W3-2005-0500-00/DRN 05-1559
Revision 14-A
Section 10.4.5.3 ER-W3-2005-0054-000/DRN 05-1425
Revision 14-B
Figure 10.4-1 sh 1 ER-W3-2006-0172-000/DRN 06-502
Revision 15
Section 10.2.3.6 ER-W3-2006-0164-000/DRN 06-722 Section 10.2.3.7
Section 10.2.2.1 ER-W3-2006-0047-000/DRN 06-812
Section 10.4.9.2 ER-W3-2006-0223-000/DRN 06-841 Table 10.4-2 Sh. 1 Table 10.4-4 Table 10.4-7 Sh. 2 Table 10.4-8 Table 10.4-11a
Table 10.4.9A-1 Sh. 1 ER-W3-2006-0223-000/DRN 06-907
Section 10.4.9.3.6 ER-W3-2007-0010-000/DRN 07-28 WSES-FSAR-UNIT-3 10-ix Revision 307 (07/13)
UPDATE REFERENCE LIST Chapter 10
Section Cross References
Revision 303
Section 10.4.9.1 EC-530 Section 10.4.9.2 Section 10.4.9.3.2
Revision 304
Figure 10.4-6 EC-3926 Table 10.4.9B-1 Sh. 3 Table 10.4-9B-2 Sh. 6 Table 10.4-9B-2 Sh. 7 Table 10.4.9B-2 Sh. 8 Table 10.4.9B-2 Sh. 9 Figure 10.4.9B-1
Table 10.4-12 EC-19372
Revision 305
Section 10.3.6.2 EC-29980
Revision 306
Section 10.4.10.2 EC-34060 Section 10.4.10.5 Section 10.4.9B.3.2 Section 10.4.9B.5.1.1
Section 10.4.5.5 EC-34124
Section 10.4.5.2 EC-34828 Figure 10.4-1 Sheet 1 of 2
Revision 307
Section 10.2.2.1 EC-8465 Section 10.3.5.1 Table 10.3-5 Sh. 2 of 2 Section 10.4.7.1 Section 10.4.7.3 Table 10.4-1 Table 10.4-6 Figure 10.2-1 Figure 10.2-2 Figure 10.2-3 Sh. 1 Figure 10.2-3 Sh. 2 Figure 10.2-3A Figure 10.2-3B Figure 10.2-3C Figure 10.2-3D Figure 10.2-3E Figure 10.3-2 WSES-FSAR-UNIT-3 10-x Revision 309 (06/16)
UPDATE REFERENCE LIST Chapter 10
Section Cross References
Revision 307 (Continued)
Appendix 10.4.9B EC-33720 Table 10.4-9B-1 Table 10.4-9B-2 Table 10.4-9B-3 Table 10.4-9B-4 Table 10.4-9B-5 Table 10.4-9B-6 Table 10.4-9B-7 Table 10.4-9B-8 Table 10.4-9B-9 Table 10.4-9B-10 Table 10.4-9B-11 Section 10.4.9.2
Section 10.4.9.2 EC-40342
Section 10.3.1 EC-41355 Section 10.4.9.3.1 Table 10.4-14 Table 10.4.9A-1 Sh. 2 of 7 Table 10.4.9A-2 Sh. 8 of 11
Table 10.4.9A-1 Sh. 4 of 7 EC-42115 Table 10.4.9A-1 Sh. 5 of 7
Revision 308
Table 10.4-3 EC 47045
Revision 309
Section 10.3.5.1 LBDCR 12-003
Section 10.4.9.3.2 LBDCR 15-032
Figure 10.4-1 LBDCR 14-004