Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20127C786 + (22:18:19, 12 December 2024)
- ML20127C784 + (22:18:20, 12 December 2024)
- ML20127C783 + (22:18:20, 12 December 2024)
- ML20127C782 + (22:18:21, 12 December 2024)
- ML20127C781 + (22:18:23, 12 December 2024)
- ML20127C779 + (22:18:24, 12 December 2024)
- ML20127C780 + (22:18:24, 12 December 2024)
- 05000325/LER-1985-028, :on 850514,design Error Determined in Standby Gas Treatment Sys Which Would Prevent Automatic Initiation Following Loss of Offsite Power.Plant Mods Will Be Implemented by 850708 + (22:18:26, 12 December 2024)
- ML20127C776 + (22:18:28, 12 December 2024)
- ML20127C775 + (22:18:29, 12 December 2024)
- 05000325/LER-1985-029, :on 850515,during Refueling Outage,Primary Containment Group 1 Isolation Occurred While MSIVs Closed. Caused by Shorting of Test Lead to Relay B21-K22,initiating Channel a Logic Trip Signal.Fuses Replaced + (22:18:30, 12 December 2024)
- ML20127C773 + (22:18:31, 12 December 2024)
- ML20127C771 + (22:18:33, 12 December 2024)
- ML20127C772 + (22:18:33, 12 December 2024)
- ML20127C769 + (22:18:34, 12 December 2024)
- 05000281/LER-1985-005-03, :on 850514 & 15,automatic Initiation of Hazard Zones 8 & 4,respectively,locked Out W/No Fire Watch Present. Caused by Lack of Procedure & Training.Procedure for CO2 Sys Lockouts Will Be Implemented + (22:18:35, 12 December 2024)
- ML20127C767 + (22:18:37, 12 December 2024)
- ML20127C766 + (22:18:38, 12 December 2024)
- 05000133/LER-1985-003-01, :on 850514,while Decontaminating Unirradiated Fuel Assemblies,More than One Fuel Assembly Present within Dismantlement/Decontamination Work Area.Caused by Lack of Attention to Tech Spec Requirements + (22:18:39, 12 December 2024)
- ML20127C763 + (22:18:41, 12 December 2024)
- ML20127C762 + (22:18:42, 12 December 2024)
- ML20127C758 + (22:18:43, 12 December 2024)
- ML20127C757 + (22:18:44, 12 December 2024)
- ML20127C755 + (22:18:45, 12 December 2024)
- HL-2371, Plant Ei Hatch Units 1 & 2 Semiannual Radioactive Effluent Release Rept,Jan-June 1992 + (22:18:46, 12 December 2024)
- ML20127C752 + (22:18:47, 12 December 2024)
- ML20127C751 + (22:18:48, 12 December 2024)
- ML20127C749 + (22:18:49, 12 December 2024)
- ML20127C748 + (22:18:50, 12 December 2024)
- ML20127C745 + (22:18:51, 12 December 2024)
- ML20127C744 + (22:18:52, 12 December 2024)
- ML20127C742 + (22:18:53, 12 December 2024)
- ML20127C739 + (22:18:54, 12 December 2024)
- 05000424/LER-1992-007-03, :on 920809,AFW Pump Tripped on Mechanical Overspeed During Testing.Caused by Bent Tappet Stem.Tappet Assembly Replaced + (22:18:55, 12 December 2024)
- ML20127C737 + (22:18:57, 12 December 2024)
- ML20127C736 + (22:18:58, 12 December 2024)
- ML20127C733 + (22:18:59, 12 December 2024)
- ML20127C732 + (22:19:00, 12 December 2024)
- ML20127C730 + (22:19:01, 12 December 2024)
- ML20127C726 + (22:19:04, 12 December 2024)
- 05000370/LER-1992-009-03, :on 920805,reactor Trip Occurred Due to lo-lo Water Level in SG 2B.Caused by Equipment Failure.Vibration & Temp Data Collected for Nv Sys Letdown Orifice Piping & Parallel Path Solenoids Will Be Added + (22:19:05, 12 December 2024)
- ML20127C724 + (22:19:07, 12 December 2024)
- ML20127C723 + (22:19:08, 12 December 2024)
- 05000369/LER-1992-006, :on 920430,discovered Air in Nuclear Svc Water Assured Makeup Piping Associated W/Afw Pump Suction Header Rn Supply Isolations.Caused by Design Deficiency.Continuous Venting Initiated at High Point Locations + (22:19:10, 12 December 2024)
- PLA-2169, Forwards Updated Const Status Rept as of 840331.Info for Inclusion in NUREG-0030.Const Completed & Fuel Loading Commenced + (22:19:12, 12 December 2024)
- ML20127C715 + (22:19:14, 12 December 2024)
- ML20127C714 + (22:19:14, 12 December 2024)
- 05000302/LER-1992-016, :on 920804,alert Declared When Fire Lasted for More than 10 Minutes Due to Failure in Alarm Circuit in Battery Charger.Caused by High Current.Failed Rectifier Replaced & Related Fuse Circuit Installed + (22:19:16, 12 December 2024)
- ML20127C709 + (22:19:18, 12 December 2024)
- 05000344/LER-1992-022, :on 920803,discovered That Sp Performed Following 1985 Design Change Did Not Adequately Test Train a & B Auxiliary Relay Contacts of CCW Surge Tank.Caused by Personnel Error.Relay Replaced + (22:19:20, 12 December 2024)
- ML20127C706 + (22:19:21, 12 December 2024)