- ML20198F950 + (ML20198F950)
- ML20198F951 + (ML20198F951)
- ML20198F953 + (ML20198F953)
- ML20198F955 + (ML20198F955)
- ML20198F957 + (ML20198F957)
- L-98-241, LARs 258 & 129 to Licenses DPR-66 & DPR-73,modifying TS 3/4.8.1, AC Sources for Units & Associated Bases to Clarify EDG Fuel Oil Storage Requirements by Addition of Term Usable + (ML20198F959)
- ML20198F964 + (ML20198F964)
- ML20198F966 + (ML20198F966)
- ML20198F967 + (ML20198F967)
- ML20198F968 + (ML20198F968)
- 05000331/LER-1985-042, :on 851005,two Drywell Equipment Drain Sump Timers Found Inoperable.Caused by Corrosion/Pitting on Internal Motor Power Contacts & Increased Resistance Across Contacts at Low Voltage.Timers Replaced + (ML20198F970)
- ML20198F971 + (ML20198F971)
- ML20198F973 + (ML20198F973)
- ML20198F974 + (ML20198F974)
- ML20198F977 + (ML20198F977)
- ML20198F978 + (ML20198F978)
- ML20198F979 + (ML20198F979)
- ML20198F980 + (ML20198F980)
- ML20198F984 + (ML20198F984)
- ML20198F985 + (ML20198F985)
- ML20198F986 + (ML20198F986)
- ML20198F988 + (ML20198F988)
- ML20198F992 + (ML20198F992)
- ML20198F994 + (ML20198F994)
- ML20198F995 + (ML20198F995)
- ML20198F997 + (ML20198F997)
- ML20198F998 + (ML20198F998)
- ML20198F999 + (ML20198F999)
- ML20198G000 + (ML20198G000)
- 05000272/LER-1985-012-01, :on 851006,turbine Tripped Due to Shift Supervisor Opening Vent Valve for Alarm Sensor.Caused by Troubleshooting Techniques & Sys Design.Senior Shift Supervisor Counseled + (ML20198G001)
- ML20198G002 + (ML20198G002)
- ML20198G003 + (ML20198G003)
- ML20198G005 + (ML20198G005)
- ML20198G006 + (ML20198G006)
- ML20198G007 + (ML20198G007)
- ML20198G008 + (ML20198G008)
- ML20198G009 + (ML20198G009)
- ML20198G011 + (ML20198G011)
- ML20198G012 + (ML20198G012)
- ML20198G013 + (ML20198G013)
- 05000237/LER-1985-037-03, :on 851007,reactor Bldg Ventilation Tripped & Isolated W/Standby Gas Treatment Sys Autostarting as Required.Caused by Operator Removing Wrong Fuse.Station Tailgate Session Conducted + (ML20198G015)
- ML20198G016 + (ML20198G016)
- ML20198G017 + (ML20198G017)
- ML20198G020 + (ML20198G020)
- ML20198G022 + (ML20198G022)
- ML20198G023 + (ML20198G023)
- ML20198G026 + (ML20198G026)
- ML20198G027 + (ML20198G027)
- ML20198G030 + (ML20198G030)
- ML20198G031 + (ML20198G031)
- ML20198G034 + (ML20198G034)