- 05000265/LER-1983-017-03, /03L-0:on 830924,during RCIC Turbine Area High Temp Switch Calibr QIS-28,temp Switches TS 2-1360-15B,16B & 14D Tripped Above Tech Spec Limit.Caused by Setpoint Drift. Switches Replaced + (ML20081B259)
- ML20081B263 + (ML20081B263)
- ML20081B265 + (ML20081B265)
- 05000249/LER-1983-034-03, /03L-0:on 830923,during Normal Operation,Mobile Crane Hit Wet Pipe Sprinkler Drain Valve,Breaking Valve & Spraying Water on Trackway.Caused by Personnel Error.Valve Repaired.Personnel Counseled + (ML20081B268)
- ML20081B274 + (ML20081B274)
- 05000362/LER-1983-064-03, W/Unit in Mode 2,ex-core Logarithmic Power Safety Channel C Declared Inoperable & on 830918,channel B Declared Inoperable.Caused by Failed Cable Connectors.Connectors Replaced + (ML20081B275)
- ML20081B276 + (ML20081B276)
- ML20081B277 + (ML20081B277)
- ML20081B278 + (ML20081B278)
- ML20081B281 + (ML20081B281)
- AECM-83-0668, Final Deficiency Rept PRD-83/12 for Unit 1 & Interim Rept for Unit 2 Re Failure of Agastat GP Series Relays to Switch. Initially Reported on 830902.Deficiency Reportable Per Part 21 for Unit 1.Investigation Ongoing for Unit 2 + (ML20081B284)
- 05000362/LER-1983-073-01, /01T-0:on 830929,charging & Letdown Flows Isolated by Closing Manual Isolation Valves S31208MU084 & S31208MU091 in Violation of Limiting Conditions of Operation.Caused by Personnel Error.Valves Opened on 830930 + (ML20081B295)
- L-95-007, Monthly Operating Repts for Feb 1995 for Point Beach Nuclear Plant Units 1 & 2 + (ML20081B298)
- ML20081B314 + (ML20081B314)
- ML20081B318 + (ML20081B318)
- 05000362/LER-1983-076-03, /03L-0:on 830907,during Shift Surveillance, Control Element Assembly Calculator 2 Declared Inoperable. Caused by Poorly Seated Circuit Board.Circuit Boards Resealed + (ML20081B321)
- ML20081B323 + (ML20081B323)
- ML20081B325 + (ML20081B325)
- ML20081B328 + (ML20081B328)
- ML20081B330 + (ML20081B330)
- 05000302/LER-1995-001, :on 950124,insp Determined Control Complex Habitability Envelope in Leakage Area Exceeded Requirements That Resulted in Condition Potentially Outside Design Basis. Personnel Made Aware of Importance of He + (ML20081B331)
- NG-83-3408, Discusses Scram Discharge Vol short-term Mods in Response to IE Bulletin 80-17.Water Added to Scram Discharge Vol & Vent Procedures & Drain Valve Operability & Closure Time Test Changed from Quarterly to Monthly + (ML20081B332)
- ML20081B333 + (ML20081B333)
- 05000361/LER-1983-124-03, /03L-0:on 830917 & 23,control Element Assembly Calculator Declared Inoperable Due to Spurious Position from Control Element Assembly 20.Caused by Defective Board & Connector.Equipment Replaced + (ML20081B335)
- ML20081B340 + (ML20081B340)
- 05000249/LER-1983-032-03, /03L-0:on 830921,valve LPCI 1501-11B Closed During Installation of Terminal Jumper.Caused by Technician Inadvertently Placing Terminal Jumper on 903-3 Panel Instead of 903-10 Panel + (ML20081B342)
- HL-4771, Forwards Rev 13B to FSAR for Ei Hatch Nuclear Plant & Rev 10B to Fire Hazards Analysis & Fire Protection Programs for Plant Hatch Units 1 & 2 + (ML20081B343)
- ML20081B348 + (ML20081B348)
- 05000373/LER-1983-116-03, /03L-0:on 830926,control Rod Drive (CRD) at Core Location 30-19 Indicated Overtravel When Withdrawn to Full Out Position.Caused by Inner Filter Retainer Spring Damage Due to Excessive Crud Buildup + (ML20081B354)
- ML20081B359 + (ML20081B359)
- 05000362/LER-1983-065-03, /03L-0:on 830905 & 12,w/unit in Mode 2 at Zero Power,High Range in-containment Radiation Monitor 3RI-7820-1 Found in Failed Low Condition & Declared Inoperable.Caused by Faulty Electrical Cable Penetration Path + (ML20081B362)
- ML20081B366 + (ML20081B366)
- 05000361/LER-1983-123-03, /03L-0:on 830913,w/Unit 2 in Mode 1 & Unit 3 in Mode 3,insp of Electrical Penetrations Revealed Two Holes in Penetration Seals in Auxiliary Bldg Control Area.Caused by Procedural Deficiencies During Const + (ML20081B368)
- ML20081B377 + (ML20081B377)
- ML20081B381 + (ML20081B381)
- ML20081B407 + (ML20081B407)
- ML20081B417 + (ML20081B417)
- 05000348/LER-1995-003, :on 950206,determined That Train a of Ssps Potentially Susceptible to Failure in Event of Postulated High Energy Steamline Break.Caused by Spss Design. Maintenance/Surveillance Activities Restricted + (ML20081B418)
- ML20081B422 + (ML20081B422)
- ML20081B424 + (ML20081B424)
- ML20081B428 + (ML20081B428)
- ML20081B429 + (ML20081B429)
- JAFP-95-0122, Responds to NRC Re Violation Noted in Insp Rept 50-333/95-03 on 950123-27.Corrective Actions:Portable Alarming Area Radiation Monitor RM-16 Added to Daily Insp & RP Instrument Procedure RP-INST-103 Being Updated + (ML20081B430)
- 05000370/LER-1995-001-02, :on 950208,Unit 2 Containment Penetrations Have Been Inoperable in Past Due to Failed Equipment.Caused by Unanticipated Environ Interaction.Replaced Affected Piping + (ML20081B432)
- ML20081B433 + (ML20081B433)
- ML20081B435 + (ML20081B435)
- ML20081B439 + (ML20081B439)
- JPN-95-012, Responds to NRC on Radiological Concerns & Industrial Safety Deficiencies + (ML20081B442)
- ST-HL-AE-5036, Application for Amends to Licenses NPF-76 & NPF-80,revising Ref in TS 6.9.1.6.b for Analytical Method Used to Determine Core Operating Limits for Heat Flux Hot Channel Factor for TS 3.2.2 + (ML20081B450)
- ML20081B460 + (ML20081B460)