Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20072G995 + (ML20072G995)
- 05000362/LER-1983-020-01, /01T-0:on 830203,review of ASME Test Data Revealed Error in Hydrotesting of Line from Component Cooling Water Train a to HPSI Pump 3P)17.Cause Due to Misinterpretation of Hydrostatic Test Pressure Requirement.Line Retested + (ML20072G996)
- ML20072G997 + (ML20072G997)
- ML20072G999 + (ML20072G999)
- ML20072H001 + (ML20072H001)
- ML20072H004 + (ML20072H004)
- ML20072H013 + (ML20072H013)
- ML20072H016 + (ML20072H016)
- ML20072H017 + (ML20072H017)
- ML20072H019 + (ML20072H019)
- ML20072H021 + (ML20072H021)
- ML20072H029 + (ML20072H029)
- ML20072H035 + (ML20072H035)
- HL-4648, Application for Amend to License DPR-57,proposing one-time Change to TS 3.9.C to Allow Shutdown Operations W/Only One of Two Required EDGs Aligned to Corresponding Core or Containment Cooling Sys + (ML20072H041)
- ML20072H051 + (ML20072H051)
- DCL-94-167, Forwards Public Version of Revised Corporate ERPIPs.W/940824 Release Memo + (ML20072H052)
- ML20072H053 + (ML20072H053)
- ML20072H055 + (ML20072H055)
- ML20072H057 + (ML20072H057)
- ML20072H062 + (ML20072H062)
- ML20072H071 + (ML20072H071)
- ML20072H072 + (ML20072H072)
- ML20072H081 + (ML20072H081)
- ML20072H084 + (ML20072H084)
- ML20072H086 + (ML20072H086)
- ML20072H089 + (ML20072H089)
- ML20072H094 + (ML20072H094)
- 05000361/LER-1983-021, Forwards LER 83-021/03L-0 + (ML20072H101)
- ML20072H113 + (ML20072H113)
- 05000237/LER-1983-014, Forwards LER 83-014/03L-0 + (ML20072H114)
- ML20072H130 + (ML20072H130)
- ML20072H136 + (ML20072H136)
- 05000237/LER-1983-014-03, /03L-0:on 830222,during Refueling Outage,Time Recorded for Offgas Discharge Valve A02-5406 to Fully Close Exceeded 15 Minute Tech Spec Limit.Cause Unknown.Timer Readjusted.Valve Timed to Close at 14 minutes,16 + (ML20072H138)
- ML20072H143 + (ML20072H143)
- L-83-235, Suppls 830106 Response to NRC Re Violations Noted in IE Insp Rept 50-335/82-36.Corrective Actions: Employee Responsibilities During Procedure Control & Maint Implementation Emphasized + (ML20072H144)
- ML20072H145 + (ML20072H145)
- ML20072H146 + (ML20072H146)
- ML20072H149 + (ML20072H149)
- ML20072H151 + (ML20072H151)
- ML20072H157 + (ML20072H157)
- L-83-299, Responds to NRC Re Violations Noted in IE Insp Repts 50-250/83-07 & 50-251/83-07.Corrective Actions: Requests for Relief from ASME Code Requirements Will Be Documented Prior to Insp.Disputes Noncompliance for Unit 4 + (ML20072H160)
- ML20072H162 + (ML20072H162)
- ML20072H167 + (ML20072H167)
- ML20072H169 + (ML20072H169)
- ML20072H175 + (ML20072H175)
- 05000362/LER-1983-016, Forwards LER 83-016/03L-0 + (ML20072H177)
- ML20072H178 + (ML20072H178)
- ML20072H182 + (ML20072H182)
- ML20072H190 + (ML20072H190)
- 05000362/LER-1983-016-03, /03L-0:on 830207,plant Tour Revealed Failed Temporary Instrument Line on Auxiliary Feedwater Pump Turbine Stop Valve 3HV-4716.Cause Not Stated.Line Replaced & Pump Declared Operable.Investigation Continuing + (ML20072H193)
- 05000362/LER-1983-005, Forwards LER 83-005/01T-0 + (ML20072H197)