- ML18152B202 + (ML18152B202)
- ML18152B203 + (ML18152B203)
- 05000280/LER-1988-025, :on 880815,control/relay Room Chillers Inoperable.Caused by Inadequate Svc Water Flow to Chiller Condensers as Result of Method to Start/Stop Chillers.Addl Procedure Will Be Developed + (ML18152B205)
- 05000280/LER-1988-029, :on 880815,reactor Trip & Safety Injection Occurred.Caused by Spurious Initiation of Train a High Consequence Limiting Safeguard.Relay Replaced & Limit Switch on Steam Dump Valve Adjusted + (ML18152B206)
- ML18152B208 + (ML18152B208)
- ML18152B209 + (ML18152B209)
- PNO-II-88-056, on 880914,Unit 1 Shut Down.Caused by Determination That Both Emergency Diesel Generators Would Be Overloaded If Loss of Offsite Power Occurred Between 5 & 60 Minutes After Loca.Condition Exists for Both Units + (ML18152B211)
- ML18152B212 + (ML18152B212)
- ML18152B213 + (ML18152B213)
- ML18152B216 + (ML18152B216)
- ML18152B217 + (ML18152B217)
- ML18152B218 + (ML18152B218)
- ML18152B219 + (ML18152B219)
- ML18152B220 + (ML18152B220)
- ML18152B223 + (ML18152B223)
- ML18152B228 + (ML18152B228)
- 05000281/LER-1988-022-01, :on 880910,reactor Trip by Turbine Trip Occurred While Attempting to Maintain Turbine at Synchronous Speed.Caused by Inadequate Procedure & Faulty Valve Position Indication.Testing to Be Performed + (ML18152B229)
- ML18152B231 + (ML18152B231)
- 05000280/LER-1988-036, :on 880912,charging Pump Component Cooling Water Sys Declared Inoperable When Both Charging Pump CC Pumps Became Air Bound Following Return to Service of a Intermediate Seal Cooler + (ML18152B232)
- ML18152B233 + (ML18152B233)
- ML18152B234 + (ML18152B234)
- 05000280/LER-1988-032, :on 880913,three Emergency Diesel Generators Declared Inoperable Due to Design Deficiency.Caused by Incorrect Design Assumption That Worst Case Scenario Was hi-hi Actuation.Design Change Generated + (ML18152B235)
- ML18152B238 + (ML18152B238)
- ML18152B239 + (ML18152B239)
- ML18152B240 + (ML18152B240)
- ML18152B242 + (ML18152B242)
- IR 05000280/1988033 + (ML18152B244)
- ML18152B245 + (ML18152B245)
- ML18152B246 + (ML18152B246)
- 05000280/LER-1988-037, :on 880918,electrical Penetration Not Completely Filled W/Fire Retardant Foam,Surrounding Cables as Required.Fire Watch Not Posted within Hour of Discovery. Caused by Personnel Error.Personnel Counseled + (ML18152B247)
- IR 05000280/1988028 + (ML18152B248)
- ML18152B249 + (ML18152B249)
- ML18152B250 + (ML18152B250)
- ML18152B252 + (ML18152B252)
- ML18152B253 + (ML18152B253)
- 05000280/LER-1988-038, :on 880928,three Recirculation Spray HXs Filled W/Svc Water Discovered.Caused by Leakage Past Normally Closed Recirculation Spray HX Inlet Isolation Valves.Samples Taken + (ML18152B254)
- IR 05000280/1988029 + (ML18152B255)
- ML18152B256 + (ML18152B256)
- IR 05000280/1988037 + (ML18152B258)
- ML18152B259 + (ML18152B259)
- ML18152B260 + (ML18152B260)
- PNO-II-88-067, on 881031,contractor Received Electrical Shock While Erecting Scaffolding Near 4,160-volt Transformer. Contractor Taken to Hosp & Released.No Contamination or Radiation Involved + (ML18152B261)
- ML18152B263 + (ML18152B263)
- ML18152B264 + (ML18152B264)
- IR 05000280/1988036 + (ML18152B266)
- ML18152B267 + (ML18152B267)
- ML18152B268 + (ML18152B268)
- ML18152B269 + (ML18152B269)
- ML18152B270 + (ML18152B270)
- ML18152B271 + (ML18152B271)
- ML18152B272 + (ML18152B272)