RS-14-031, Request to Dispose of Slightly Contaminated Soil in Accordance with 10 CFR 20.2002

From kanterella
(Redirected from RS-14-031)
Jump to navigation Jump to search
Request to Dispose of Slightly Contaminated Soil in Accordance with 10 CFR 20.2002
ML14077A140
Person / Time
Site: Dresden  
Issue date: 03/18/2014
From: Simpson P
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RS-14-031
Download: ML14077A140 (193)


Text

RS-14-031 March 18, 2014 10 CFR 20.2002 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Dresden Nuclear Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-19 and DPR-25 NRC Docket Nos. 50-237 and 50-249

Subject:

Request to Dispose of Slightly Contaminated Soil In Accordance With 10 CFR 20.2002 In accordance with 10 CFR 20. 2002, "Method for obtaining approval of proposed disposal procedures," Exelon Generation Company, LLC (EGC), requests NRC approval of the attached request to dispose of slightly contaminated soil onsite at Dresden Nuclear Power Station, Units 2 and 3 (DNPS). Specifically, EGC requests permission to spread the current inventory of approximately 6,000 cubic meters (m) of soil as described in Attachment 1, and approval to conduct future disposal operations onsite within the bounds of the radiological dose assessment provided in Attachment 2, not to exceed a total volume of 20,000 m3. The Attachment 2 analysis determined that disposing of the soil in the proposed manner will limit the radiological dose received by the maximally exposed individual to less than five millirem per year both during and after NRC-licensed activities.

EGC requests approval of this request by March 18, 2015.

There are no regulatory commitments contained within this letter. Should you have any questions concerning this letter, please contact Mr. Mitchel A. Mathews at (630) 657-2819.

Respectfully, Attachments:

1.

Evaluation of Proposed 10 CFR 20.2002 Disposal Procedure 2.

DRE-13-001, "Dresden On-Site Soil Disposal Assessment and Derivation of Single Soil DCGL," Revision 1

ATTACHMENT 1 Evaluation of Proposed 10 CFR 20.2002 Disposal Procedure Page 1 of 5

Subject:

Request to Dispose of Slightly Contaminated Soil In Accordance With 10 CFR 20.2002

1.0 BACKGROUND

2.0 DESCRIPTION

OF THE WASTE CONTAINING LICENSED MATERIAL 2.1 Physical and Chemical Properties of Material Important to Risk Evaluation 2.2 Proposed Manner of Waste Disposal 2.3 Conditions of Waste Disposal 3.0 ANALYSIS AND EVALUATION OF PERTINENT INFORMATION ON NATURE OF THE ENVIRONMENT 4.0 NATURE AND LOCATION OF OTHER POTENTIALLY AFFECTED LICENSED AND UNLICENSED FACILITIES 5.0 ANALYSIS AND PROCEDURES TO ENSURE THAT DOSES ARE MAINTAINED ALARA AND WITHIN THE 10 CFR 20 DOSE LIMITS 6.0 RECORDKEEPING REQUIREMENTS

7.0 REFERENCES

ATTACHMENT 1 Evaluation of Proposed 10 CFR 20.2002 Disposal Procedure Page 2 of 5

1.0 BACKGROUND

As of March 2014, Exelon Generation Company, LLC (EGC) has accumulated approximately 6,000 cubic meters (m3) of soils containing trace quantities of residual radioactive materials on-site at Dresden Nuclear Power Station (DNPS), Units 2 and 3. The majority of the soils collected were generated from the following DNPS projects:

2011-2012 Condensate storage tank level instrumentation piping replacement 2011 Radwaste tank farm piping replacement 2010 Unit 3 low pressure coolant injection system pipe replacement 2010 Units 2 and 3 condensate transfer/make-up pipe replacement and carbon fiber wrap 2009 Condensate Tank 105A pipe repair 2006 Units 2 and 3 high pressure coolant injection pipe replacement Initial cost estimates projected more than $4,000,000 for transportation and disposal of the current inventory of soils excluding on-site labor and management costs.

The soils contain trace quantities of radionuclides (i.e., byproduct material) which analysis has determined is well below the license termination criteria defined in 10 CFR 20.1402, "Radiological criteria for unrestricted use." Therefore, disposal of the soil in the proposed manner is not likely to require remediation upon facility license termination.

Considering the high costs of shipping and disposal as well as the minimal radiological hazard associated with the soils, on-site disposal is highly desirable.

A dose assessment analysis, included as Attachment 2, was performed to determine the feasibility of disposing of this material onsite in accordance with 10 CFR 20.2002, "Method for obtaining approval of proposed disposal procedures." The conceptual models employed for this dose assessment are detailed in the RESRAD Version 6 Users Manual. The specific model employed for this analysis, RESRAD Version 6.5, was developed under the joint sponsorship of the U. S. Department of Energy and the NRC for site-specific dose assessments of residual radioactivity.

As described in Attachment 2, Section 2.1, Derived Concentration Guideline Levels (DCGLs) are radionuclide-specific concentration limits used by licensees during decommissioning activities to achieve the regulatory dose standards that permit the release of the property and allow termination of the operating license by the NRC. The analysis used radionuclide-specific DCGLs to verify that the total dose in millirem per year (mrem/yr) from all radionuclides present in the material proposed for disposal will meet the requirements of 10 CFR 20 Subpart E, "Radiological Criteria for License Termination," by using the sum of fractions (SOF).

As discussed in Attachment 2, Section 3.2, "Critical Groups, Scenarios, Pathways, Identification and Selection," the derived DCGLs from three exposure scenarios were evaluated. The three evaluated scenarios for exposure were "The Industrial Worker (i.e., individual exposed during EGC licensed activities)," "The Recreationist," and "The Resident Farmer."

ATTACHMENT 1 Evaluation of Proposed 10 CFR 20.2002 Disposal Procedure Page 3 of 5 The analysis found that the Resident Farmer scenario results in the most restrictive DCGLs.

Therefore, by adopting the Resident Farmer based DCGLs and ensuring the average soil concentrations do not exceed 20% with SOF applied to meet as low as reasonably achievable (ALARA) principles, the other scenario doses may be determined by multiplying the five mrem/yr associated with being 20% of the 25 mrem/yr basic dose limit by a percentage of the Resident Farmer exposure.

For example, consider if the soil averaged 0.5642 pico curies per gram of Cobalt-60 (i.e., 20% of the DCGL):

The Resident Farmer scenario would result in five mrem/yr.

The Industrial Worker would result in five mrem/yr x 28.889% = 1.4 mrem/yr.

The Recreationist would result in five mrem/yr x 2.032% = 0.1 mrem/yr In summary, soils that average 20% of the Resident Farmer DCGLs will result in a maximum exposure of five mrem/yr and dose to an Industrial Worker or Recreationist of less than five mrem/yr.

2.0 DESCRIPTION

OF THE WASTE CONTAINING LICENSED MATERIAL 2.1 Physical and Chemical Properties of Material Important to Risk Evaluation As described in Attachment 2, Section 3.1, "Source Term," the waste associated with this request is restricted to soils and sewage treatment drying bed wastes. The residual byproduct materials are primarily solid metal oxides, and there are no other environmentally hazardous chemicals or constituents associated with this request.

2.2 Proposed Manner of Waste Disposal EGC proposes a disposal of the materials described above in the Restricted Area of the DNPS Owner Controlled Area as defined in 10 CFR 20.1003. An overhead photo of the proposed disposal site is shown in Attachment 2, Section 3.1, Figure 1. The proposed disposal site is a 100 meter by 100 meter plot of land which will accommodate the disposal of soil up to two meters high. The materials will be sampled and evaluated to ensure compliance with the proposed procedural requirements. The material, if sample results indicate acceptable, will be transferred to the disposal site, and evenly graded to a depth not to exceed two meters. The materials will then be over-seeded to address EGC Storm Water Management Program concerns (e.g., silt run-off in to the river) and to ensure the material remains on the disposal site. The disposal will be controlled by procedure, and will be posted with signage that will require contacting DNPS Radiation Protection Department personnel prior to disturbing the soil within the proposed disposal site.

ATTACHMENT 1 Evaluation of Proposed 10 CFR 20.2002 Disposal Procedure Page 4 of 5 2.3 Conditions of Waste Disposal EGC proposes to limit the disposal to waste containing licensed material that does not exceed the DCGLs with the SOF rule applied as described in Attachment 2, Enclosure 1, "Single Soil DCGL that Results in 25 mrem/yr to an Average Member of the Critical Group."

To demonstrate adherence with NRC and industry ALARA radiological dose principles, the average concentration of the disposed volume of licensed material will be kept to 20% of the DCGLs (i.e., with the sum of fractions rule applied).

The waste proposed for disposal will meet the State of Illinois Environment Protection Agency (IL EPA) definition of "uncontaminated soil." Materials suspected of containing environmentally hazardous chemical constituents will be sampled and analyzed to determine if hazardous substances are present. If identified, the hazardous material will be sequestered, contained, and disposed of in accordance with IL EPA requirements and EGC procedures.

3.0 ANALYSIS AND EVALUATION OF PERTINENT INFORMATION ON NATURE OF THE ENVIRONMENT The pertinent information related to the nature of the environment that were utilized in the RESRAD, Version 6.5 analysis are described in Attachment 2, Section 3.4, "Calculations and Input Parameters."

4.0 NATURE AND LOCATION OF OTHER POTENTIALLY AFFECTED LICENSED AND UNLICENSED FACILITIES The materials proposed for disposal will remain within the DNPS Restricted Area. The nearest facility is the General Electric (GE) Boiling Water Reactor (BWR) Spent Fuel Storage facility which is approximately 0.7 miles to the southwest of DNPS. No impact to this facility or any other licensed or unlicensed facility is expected.

5.0 ANALYSIS AND PROCEDURES TO ENSURE THAT DOSES ARE MAINTAINED ALARA AND WITHIN THE 10 CFR 20 DOSE LIMITS DCGLs have been determined for nuclides that are proposed for disposal. The DCGLs were calculated assuming that a hypothetical "Resident Farmer" would receive a maximum of 25 mrem/yr.

The limit of 25 mrem/yr was chosen to ensure that no legacy issues are created related to the guidance found in 10 CFR 20.1402. This will ensure that the DNPS site will meet applicable public dose requirements at the time of license termination. To further demonstrate compliance with NRC and industry ALARA principles, the average of the disposed volume of licensed

ATTACHMENT 1 Evaluation of Proposed 10 CFR 20.2002 Disposal Procedure Page 5 of 5 material will be limited to ensure average concentration of radionuclides is 20% of the limiting DCGLs using the sum of fractions rule.

This methodology is consistent with the guidance provided in NUREG-1757, Volume 2, "Consolidated Decommissioning Guidance: Characterization, Survey, and Determination of Radiological Criteria," Revision 1.

6.0 RECORDKEEPING REQUIREMENTS EGC complies with 10 CFR 20.2108 recordkeeping requirements through the use of the Quality Assurance Topical Report (QATR) which describes retention of records required by regulation.

These requirements are implemented through Exelon Procedures RM-AA-101, "Records Management Program," and RM-AA-101-1004, "Standard Records Retention Schedule."

EGC records associated with the proposed onsite disposal will be recorded and maintained until the NRC terminates the license requiring the records. Records of the disposal that will be maintained include the following:

1. Radionuclide concentrations detected in the material
2. Total volume of material disposed
3. Total radioactivity in the disposal operation as well as the total radioactivity accumulated on the disposal plot at the time of spreading
4. Drawings and/or photographs showing the plot of land on which the material was applied; and
5. Dose calculations or maximum allowable accumulated activity determinations required to demonstrate that the approved dose values have not been exceeded.

7.0 REFERENCES

The references associated with the analysis are located in Attachment 2, Section 4, "References."

ATTACHMENT 2 Dresden Nuclear Power Station Request to Dispose of Slightly Contaminated Soil In Accordance With 10 CFR 20.2002 DRE-13-001, "Dresden On-Site Soil Disposal Assessment and Derivation of Single Soil DCGL," Revision 1

DRE-13-001 Revision 1 Page 1 of 13 SRRS: 2B.134 DRESDEN ON-SITE SOIL DISPOSAL DOSE ASSESSMENT AND DERIVATION OF SINGLE SOIL DCGLS Prepared by: Jeffrey J Cady, MS, CHP, NRRPT (Print & Sign) Signature on file Date:

01/15/2014 Reviewed by: Jack McCarthy, CHP, NRRPT (Print & Sign) Signature per attached e-mail notification Date:

01/15/2014 Approved by: Jeffrey J Cady, MS, CHP, NRRPT (Print & Sign) Signature on file Date:

01/15/2014

DRE-13-001 Revision 1 Page 2 of 13 SRRS: 2B.134

1.

PURPOSE 1.1.

The Dresden Nuclear Power Station is evaluating an on-site disposal option of soils containing residual levels of plant licensed material. This technical paper documents a dose assessment and related assumptions in support of the on-site disposal evaluation and application.

1.2.

Dresden commits to using radionuclide-specific Derived Concentration Guideline Levels (DCGL) to ensure that the total dose from all radionuclides will meet the requirements of 10 CFR 20 Subpart E by using the sum of fractions (SOF).

2.

TERMS AND DEFINITIONS 2.1.

Derived Concentration Guideline Level (DCGL). Radionuclide-specific concentration limits used by the licensee during decommissioning to achieve the regulatory dose standard that permits the release of the property and termination of the license.

3.

DOSE ASSESSMENT Note:

This outline is based on the NRCs evaluation criteria described in NUREG-1757, Vol.2, Rev. 1 Section 5.2 Unrestricted Release Using Site-Specific Information (Decommissioning Groups 4-5) 3.1.

Source Term Disposal Volume - The total disposal volume being requested is 20,000 m3 of soils and sludges. As of January 2013, Dresden has accumulated on-site approximately 6,000 m3 of soils containing trace quantities of residual radioactive materials. The majority of the collected soils were generated from the following projects:

  • 2011-2012 CST Level Instrumentation Piping Replacement
  • 2011 RW Tank Farm Piping Replacement
  • 2010 U3 LPCI Pipe Replacement 2010 U2/3 Condensate Transfer/Make-Up Pipe Replacement &

Carbon Fiber Wrap

  • 2009 Condensate Tank 105A Pipe Repair
  • 2006 2/3 HPCI Pipe Replacement Documentation indicates that plant licensed material was detected in soil samples taken from each of these projects.

DRE-13-001 Revision 1 Page 3 of 13 SRRS: 2B.134 Ten samples were collected from the accumulated soil and were analyzed by Teledyne Brown Engineering for radionuclides associated with the 10 CFR Part 61 program. A summary of the sample results is provided in the table below.

Table 1 - Summary of Sample Results from Current Soil Inventory Radionuclide Minimum (pCi/g)

Average (pCi/g)

Standard Deviation (1)

Maximum (pCi/g)

K-40 (naturally occurring) 7.92X100 1.02X100 1.26 X100 1.17X10+1 Co-60 7.42X10-2 1.76X10-1 1.40X10-1 4.01X10-1 Cs-137 4.62X10-1 1.03X100 5.53X10-1 2.33X100 Ra-226 (naturally occurring) 1.35X100 1.35X100 3.53 X10-1 1.35X100 Th-232 (naturally occurring) 2.12X10-1 3.48X10-1 7.86X10-2 4.81X10-1 U-235 (naturally occurring) 8.17X10-2 8.17X10-2 2.15X10-2 8.17X10-2 Other nuclides analyzed for but determined to be less than MDA include:

Be-7, Cr-51, Mn-54, Co-57, Co-58, Fe-59, Zn-65, Nb-94, Nb-95, Zr-95, Mo-99, Ru-103, Ru-106, Ag-110m, Sn-113, Sb-124, Sb-125, I-131, Cs-134, Ba-140, La-140, Ce-141, Ce-144, Eu-154, Hf-181, Ra-226, Np-237, Am-241, Cm-242, Cm-243/244, Pu-238, Pu-239/240, Pu-241, Pu-242.

The Cs-137 value includes the background contribution from Cesium in the environment as a result of human activities (e.g., atomic bomb testing.) The values listed above are consistent with typical environmental values published in other peer reviewed literature. For comparison, Cs-137 concentration in the top layer of soils in Nebraska have been demonstrated to be from none detectable to 216 Bq/kg (6 pCi/g) (Weesner et al.)

Disposal Location - The assumed source term for this assessment is based on a 100 meter (m) by 100 m by 2 m plot of soil located on the Owner Controlled Area (OCA) on the north side of the property. This allows for a total disposal capacity of 20,000 m3. The proposed foot print is shown in the Figure 1.

DRE-13-001 Revision 1 Page 4 of 13 SRRS: 2B.134 Figure 1 - Proposed On-site Disposal Area Residual Radioactivity Spatial Variability

  • For modeling purposes, the plot of soil will be assumed to have a homogenous concentration of contamination throughout the 20,000 m3 of soil.

Radionuclides of Concern

  • Historical samples demonstrate that the two primary nuclides of concern are Co-60 and Cs-137.
  • DCGLs are developed in this paper for a variety of nuclides based on some of the typical nuclides included on 10 CFR 61 off-site vendor analysis reports. Note that nuclides whose half-lives are less than 60 days have been omitted.

Chemical Form - Considering the source of soil contamination is primarily from excavated soils associated with the repair of leaking piping, the contamination in the soil is expected to be primarily solid metal oxides and tritiated water from residual moisture content of the soil.

North

DRE-13-001 Revision 1 Page 5 of 13 SRRS: 2B.134 Environmentally Hazardous Constituents - The modeling associated with this dose evaluation does not address other environmentally hazardous constituents. There is no intent to request authorization to dispose of materials containing environmentally hazardous constituents at this time.

3.2.

Critical Groups, Scenarios, Pathways, Identification and Selection Scenario and Critical Group Identification Three exposure scenarios are included in this document.

  • To model dose upon license termination, a Resident Farmer scenario is appropriate and a conceivable use for the land upon license termination. Unless explicitly stated in section 3.4 of this document, the default parameters associated with RESRAD Version 6 were utilized. Those parameters that were changed are based on site specific data.
  • The Industrial Worker use scenario is included to evaluate potential dose to workers over the remaining life of the license.
  • Dresden allows employees to bow hunt on this area of the property therefore the Recreational User use scenario was included to evaluate any additional exposure to those employees that utilize the benefit.

Exposure Pathways - The exposure pathways associated with each of the three scenarios evaluated are listed in Table 2.

DRE-13-001 Revision 1 Page 6 of 13 SRRS: 2B.134 Table 2 - Summary of Scenarios and Applicable Pathways Pathway Resident Farmer Industrial Worker Recreationist Direct radiation from byproduct materials in the soil Yes Yes Yes Inhalation of re-suspended dust Yes Yes Yes Inhalation of radon and its decay products Yes Yes Yes Ingestion of food from crops grown in the soil containing byproduct materials Yes No No Ingestion of milk from livestock raised in the area containing byproduct materials Yes No No Ingestion of meat from livestock raised in the area containing byproduct materials Yes No Yes Ingestion of fish from a nearby pond containing byproduct materials from water percolating through the soil containing byproduct materials Yes No Yes Ingestion of water from a well or pond containing byproduct materials from water percolating through the soil containing byproduct materials, and Yes No No Ingestion of soil containing byproduct materials Yes Yes Yes 3.3.

Conceptual Models - The conceptual models employed for this dose assessment are detailed in the RESRAD Version 6 Users Manual. The RESRAD Version 6.5 was developed under the joint sponsorship of the U.S. Department of Energy and the U.S. Nuclear Regulatory Commission for site-specific dose assessment of residual radioactivity.

DRE-13-001 Revision 1 Page 7 of 13 SRRS: 2B.134 3.4.

Calculations and Input Parameters Unless otherwise specified in Table 3, default models and conceptual parameters associated with RESRAD Version 6.5 were used. All parameters were evaluated and were found to be a reasonable representation of Dresdens conditions or of a conservative nature.

The site geological data from Dresdens UFSAR is summarized in Figure 2. The Information was used to select various soil parameters. The following generalizations are made to support the dose assessment:

  • The contaminated zone is assumed to be 2 m thick and of a sandy-loam soil consistency.
  • The mantle is the unsaturated layer and is assumed to be 1.7 m thick and of a sandy-loam soil consistency.
  • A single saturated layer, 12 m thick, will represent both the Spoon Formation (sandstone) and the Fort Atkinson Limestone formation which formulates the upper aquifer. The characteristics of sandstone provide more conservative model parameters and will thus be used to model the saturated layer.
  • The Scales shale represents an impermeable layer and separates the lower and upper aquifers in this geological region. The dose assessment assumes that all water is taken from the upper aquifer and represents a conservative assumption.

DRE-13-001 Revision 1 Page 8 of 13 SRRS: 2B.134 Figure 2 - Summary of Site Geological Data The following table describes the parameters that were changed from the default value and the reason for the change.

DRE-13-001 Revision 1 Page 9 of 13 SRRS: 2B.134 Table 3 - Site-Specific Modeling Parameters and Assumptions.

Input Screen Parameter Default Value Actual Value Reason B-1 Dose conversion factors for inhalation, mrem/pCi Note that there may be differences between the Base Case and the Current Value for DCFs; that include daughter products that are also radioactive, RESRAD sums the DCFs of the parent and some of the daughter products as described in the RESRAD Users Manual.

D-1 Dose conversion factors for ingestion, mrem/pCi Note that there may be differences between the Base Case and the Current Value for DCFs; that include daughter products that are also radioactive, RESRAD sums the DCFs of the parent and some of the daughter products as described in the RESRAD Users Manual.

R012 Initial principle radionuclide (one entry per each radionuclide) 100 1

The purpose of this analysis is to establish single soil DCGLs which is independent of the values entered here. One pCi/g was selected as it is much closer to realistic environmental concentrations that may be encountered in this case.

R013 Density of contaminated zone (g/cm3) 1.5 1.44 Based on Sandy loam in Table 2.1 the RESRAD Data Collection Manual R013 Contaminated zone b parameter 5.3 4.38 Based on Sandy loam in Table E.2 of the RESRAD Users Manual R014 Saturated zone total porosity 0.4 0.34 Based on Sandstone (medium) in Table E.8 of the RESRAD Users Manual R014 Saturated zone effective porosity 0.2 0.27 Based on Sandstone (medium) in Table E.8 of the RESRAD Users Manual

DRE-13-001 Revision 1 Page 10 of 13 SRRS: 2B.134 Input Screen Parameter Default Value Actual Value Reason R014 Saturated zone b parameter 5.3 4.05 Based on Sand in Table E.2 of the RESRAD Users Manual R015 Unsaturated zone thickness (m).

4 1.7 Site specific data.

R015 Unsaturated zone soil density (g/cm3) 1.5 1.44 Based on Sandy loam in Table 2.1 the RESRAD Data Collection Manual R015 Unsaturated zone b parameter 5.3 4.38 Based on Sandy loam in Table E.2 of the RESRAD Users Manual R017 Inhalation rate (m3/yr) 8,400 8,400 11,400 14,000 Resident Farmer default Industrial Worker default Recreationist default R017 Exposure duration (yr) 30 30 25 30 Resident Farmer default Industrial Worker default Recreationist default R017 Fraction of time spent indoors 0.50 0.50 0.17 Resident Farmer default Industrial Worker default Recreationist default R017 Fraction of time spent outdoors (on site) 0.25 0.25 0.06 0.006 Resident Farmer default Industrial Worker default Recreationist default

DRE-13-001 Revision 1 Page 11 of 13 SRRS: 2B.134 3.5.

DCGL Values The results of the analyses are included in:

  • Enclosure 4, RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Resident Farmer Scenario, January 10, 2014.
  • Enclosure 5, RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Industrial Worker Scenario, January 10, 2014.
  • Enclosure 6, RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Recreationist Scenario, January 10, 2014.

The most restrictive single soil DCGLs are referenced from report page 47 of, page 45 of Enclosure 5, and page 47 of Enclosure 6 and are reproduced for each nuclide in Enclosure 2. Based on the comparison, the Resident Farmer Scenario DCGLs were chosen as the appropriate DCGLs for permit application and are reproduced in Enclosure 1 for clarity. Refer to Section 3.7 of this document for appropriate use of the DCGLs.

3.6.

Uncertainty Analysis The guidance provided in NUREG-1757, Vol. 2, Rev. 1 states that a qualitative assessment of uncertainty analysis may be sufficient for relatively simple modeling scenarios. The model and assumptions included in this dose assessment and derivation were based on the most conservative critical use group (i.e., the Resident Farmer) and assumed conservative soil parameters that to derive at DCGL that will most likely overestimate the dose to the average member of the critical group might receive.

3.7.

Compliance with Regulatory Criteria 10CFR20.1402 Radiological criteria for unrestricted use states that a site will be considered acceptable for unrestricted use if the residual radioactivity that is distinguishable from background results in a TEDE to an average member of the critical group does not exceed 25 mrem per year.

For soils containing multiple radionuclides, a SOFs technique may be applied using the measured concentrations and the single soil DCGLs listed in Enclosure 1. Where the SOFs result in a value of 1, compliance is appropriately demonstrated and doses are not expected to exceed 25 mrem per year.

DRE-13-001 Revision 1 Page 12 of 13 SRRS: 2B.134 10CFR20.1402 Radiological criteria for unrestricted use also states that residual radioactivity must be reduced to levels that are as low as reasonably achievable (ALARA). NUREG-1757, Vol. 2, Rev. 1 provides additional guidance and states that an acceptable approach to demonstrate ALARA is to establish a pre-determined acceptable dose limit or concentration guidelines. To demonstrate ALARA, an administrative limit may be imposed when applying the SOFs rule to the average soil concentrations such that the sum is 0.2. This would ensure that the estimated dose to an average member of the critical group does not exceed 5 mrem per year.

4.

REFERENCES 4.1.

10CFR20 Subpart E - Radiological Criteria for License Termination 4.2.

10CFR61 Subpart E - Radiological Criteria for License Termination 4.3.

ANL/EAD-4, Users Manual for RESRAD Version 6. Argonne National Laboratory, Argonne, IL. July 2001.

4.4.

C. Yu, C. Loureiro, J.-J. Cheng, L.G. Jones, Y.Y. Wang, Y.P. Chia,* and E. Faillace, Data Collection Handbook to Support Modeling Impacts of Radioactive Material in Soil. Argonne National Laboratory, Argonne, IL. April 1993.

4.5.

Dresden Power Station Updated Final Safety Analysis Report (UFSAR) Revision 9, Dresden Nuclear Power Station, Unit 2 and 3 Facility Operating License Nos.

(Renewed) DPR-19 (Unit 2) and DPR-25 (Unit 3) NRC Docket Nos. STN 50-237 (Unit 2) and 50-249 (Unit 3), June 2011 4.6.

NUREG-1575, Rev. 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). EPA 402-R-97-016, Rev. 1, DOE/EH-0624, Rev. 1. U.S.

Department of Defense, U.S. Department of Energy, U.S. Environmental Protection Agency, and NRC: Washington, DC. August 2000. Corrected pages for MARSSIM, Revision 1 (August 2000) with the June 2001 updates, are available at the EPA Web site: http://www.epa.gov/radiation/marssim.

4.7.

NUREG-1757, Vol. 2, Rev. 1, Consolidated Decommissioning Guidance -

Characterization, Survey, and Determination of Radiological Criteria. NRC:

Washington, DC. September 2006.

4.8.

Weesner AP, Fairchild RW. Concentration of 137Cs in Soil Across Nebraska. Health Phys 94(6):574-580, June 2008

DRE-13-001 Revision 1 Page 13 of 13 SRRS: 2B.134

5.

ENCLOSURES 5.1., Single Soil DCGL that Results in 25 mrem/yr to an Average Member of the Critical Group.

5.2., Comparison and Conclusion of DCGLs for Three Exposure Scenarios.

5.3., Demonstration of Application of the DCGLs and SOF to Demonstrate Compliance with Dose Criteria.

5.4., RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Resident Farmer Scenario, January 10, 2014.

5.5., RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Industrial Worker Scenario, January 10, 2014.

5.6., RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Recreationist Scenario, January 10, 2014.

DRE-13-001 Revision 1 SRRS: 2B.134 ENCLOSURE 1 Single Soil DCGL that Results in 25 mrem/yr to an Average Member of the Critical Group.

Page 1 of 1 Nuclide Single Soil DCGL (pCi/g)

Most Sensitive Pathway Peak Dose Time Frame (years)

Ag-110m 5.11E+00 Ground 0

Am-241 2.01E+00 Water 300 C-14 1.89E+01 Plant 0

Ce-144 2.01E+02 Ground 0

Cm-242 3.01E+03 Plant 0

Cm-243 3.95E+01 Ground 0

Co-57 1.28E+02 Ground 0

Co-58 2.72E+01 Ground 0

Co-60 2.82E+00 Ground 0

Cs-134 5.01E+00 Ground 0

Cs-137 1.10E+01 Ground 0

Eu-154 5.99E+00 Ground 0

Fe-55 9.72E+04 Meat 0

H-3 1.46E+03 Water 1

I-129 2.24E-01 Water 3

Mn-54 1.23E+01 Ground 0

Nb-94 5.98E+00 Water 3

Ni-59 1.49E+04 Plant 0

Ni-63 5.45E+03 Plant 0

Np-237 2.85E+00 Plant 0

Pu-238 6.32E+01 Plant 0

Pu-239 5.69E+01 Plant 0

Pu-241 6.08E+01 Water 300 Pu-242 5.99E+01 Plant 0

Ru-106 8.02E+00 Water 1

Sb-124 1.89E+01 Ground 0

Sb-125 2.25E+01 Water 1

Sn-113 8.56E+01 Ground 0

Sr-90 5.02E+00 Plant 0

Tc-99 2.77E+01 Water 3

Zn-65 1.04E+01 Ground 0

Zr-95 2.07E+01 Ground 0

DRE-13-001 Revision 1 SRRS: 2B.134 ENCLOSURE 2 Comparison and Conclusion of DCGLs for Three Exposure Scenarios.

Page 1 of 2 The chart on page 2 of this enclosure compares the derived DCGLs from the three scenarios and compares the Industrial Worker and Recreationist values to those of the Resident Farmer Scenario.

As can be seen from the chart, the Resident Farmer scenario results in the most restrictive DCGLs. By adopting the Resident Farmer based DCGLs and ensuring the average soil concentrations do not exceed 20% (SOF applied) to meet ALARA requirements, the other scenario doses may be determined by multiplying the 5 mrem (associated with being 20% of the 25 mrem/yr basic dose limit) by the percentage listed on the chart.

For example, consider if the soil averaged 0.5642 pCi/g Co-60 (20% of the DCGL):

  • The Resident Farmer scenario would result in 5 mrem.
  • The Industrial worker would result in 5 mrem
  • 28.889% = 1.4 mrem.
  • The Recreationist would result in 5mrem
  • 2.032% = 0.1 mrem In summary, soils that average 20% of the Resident Farmer DCGLs will result in a maximum of 5 mrem/yr and dose to an Industrial Worker or Recreationist will be less than 5 mrem/yr.

DRE-13-001 Revision 1 SRRS: 2B.134 ENCLOSURE 2 Comparison and Conclusion of DCGLs for Three Exposure Scenarios.

Page 2 of 2 Resident Farmer (RF)

Industrial Worker

% of RF Recreationist

% of RF Ag-110m 5.108E+00 1.881E+01 27.156%

4.579E+02 1.116%

Am-241 2.007E+00 5.115E+02 0.392%

1.995E+02 1.006%

C-14 1.889E+01 4.145E+05 0.005%

4.015E+01 47.049%

Ce-144 2.009E+02 6.867E+02 29.256%

2.041E+04 0.984%

Cm-242 3.010E+03 3.075E+04 9.789%

3.949E+05 0.762%

Cm-243 3.948E+01 1.977E+02 19.970%

4.853E+03 0.814%

Co-57 1.280E+02 4.487E+02 28.527%

5.278E+03 2.425%

Co-58 2.715E+01 9.210E+01 29.479%

1.962E+03 1.384%

Co-60 2.821E+00 9.765E+00 28.889%

1.388E+02 2.032%

Cs-134 5.013E+00 1.854E+01 27.039%

1.065E+02 4.707%

Cs-137 1.103E+01 4.421E+01 24.949%

1.476E+02 7.473%

Eu-154 5.990E+00 2.009E+01 29.816%

5.938E+02 1.009%

Fe-55 9.720E+04 5.492E+06 1.770%

1.304E+05 74.540%

H-3 1.457E+03 2.216E+05 0.657%

1.379E+04 10.566%

I-129 2.238E-01 7.032E+03 0.003%

4.105E+00 5.452%

Mn-54 1.225E+01 4.211E+01 29.090%

1.218E+03 1.006%

Nb-94 5.980E+00 2.242E+01 26.673%

4.017E+02 1.489%

Ni-59 1.491E+04 1.367E+07 0.109%

1.937E+05 7.697%

Ni-63 5.448E+03 5.019E+06 0.109%

7.076E+04 7.699%

Np-237 2.850E+00 1.056E+02 2.699%

9.317E+01 3.059%

Pu-238 6.317E+01 6.863E+02 9.204%

3.592E+03 1.759%

Pu-239 5.691E+01 6.194E+02 9.188%

3.237E+03 1.758%

Pu-241 6.075E+01 2.047E+04 0.297%

6.036E+03 1.006%

Pu-242 5.994E+01 6.514E+02 9.202%

3.408E+03 1.759%

Ru-106 8.017E+00 2.219E+02 3.613%

4.027E+02 1.991%

Sb-124 1.890E+01 6.419E+01 29.444%

1.885E+03 1.003%

Sb-125 2.253E+01 9.849E+01 22.875%

9.919E+02 2.271%

Sn-113 8.562E+01 3.190E+02 26.840%

2.658E+03 3.221%

Sr-90 5.022E+00 4.652E+03 0.108%

3.149E+01 15.948%

Tc-99 2.771E+01 1.072E+06 0.003%

1.437E+04 0.193%

Zn-65 1.042E+01 8.790E+01 11.854%

2.410E+01 43.237%

Zr-95 2.072E+01 6.951E+01 29.809%

2.073E+03 1.000%

DRE-13-001 Revision 1 SRRS: 2B.134 ENCLOSURE 3 Demonstration of Application of the DCGLs and SOF to Dresdens Current Soil Inventory to Demonstrate Compliance with Dose Criteria.

Page 1 of 1 The following demonstrates how the derived single soil DCGLs and the SOF may be used to demonstrate compliance with the 10CFR20 Subpart E - Radiological Criteria for License Termination dose criteria.

Assumptions:

1. Table 1 of this document summarizes sample results from a preliminary sampling campaign that was intended to identify the primary nuclides of concern. Although additional surveys are required to verify there are no elevated pockets of soil within the volume, the average concentration will be utilized in this example to demonstrate the concept.
2. The single soil DCGLs listed in Enclosure 1 are utilized.
3. Screening surveys are conducted to verify there are no localized volumes of soil containing radionuclides in concentrations significantly above the average.
4. If the SOF is 0.2 the soil meets the 10CFR20 Subpart E dose and ALARA criteria.

Acceptance Criteria:

Conceptually:

2.0

DCGL Nuclide Individual ion Concentrat Nuclide Measured Individual As applicable to this example SOF DCGL Cs ion Concentrat Soil Cs DCGL Co ion Concentrat Soil Co

=

+

137 137 60 60 156

.0

/

11

/

10 03

.1

/

82

.2

/

10 76

.1 0

1

=

+

g pCi g

pCi X

g pCi g

pCi X

2.0 156

.0

Since the SOF for the average nuclide concentrations is less than the acceptance criteria, the soil would be considered acceptable for on-site disposal.

DRE-13-001 Revision 1 SRRS: 2B.134 ENCLOSURE 4 RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Resident Farmer Scenario (56 pages total)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 1 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary... 2 Site-Specific Parameter Summary.......................... 13 Summary of Pathway Selections............................ 24 Contaminated Zone and Total Dose Summary................. 25 Total Dose Components Time = 0.000E+00.................................... 28 Time = 1.000E+00.................................... 30 Time = 3.000E+00.................................... 32 Time = 1.000E+01.................................... 34 Time = 3.000E+01.................................... 36 Time = 1.000E+02.................................... 38 Time = 3.000E+02.................................... 40 Time = 1.000E+03.................................... 42 Dose/Source Ratios Summed Over All Pathways.............. 44 Single Radionuclide Soil Guidelines...................... 47 Dose Per Nuclide Summed Over All Pathways................ 49 Soil Concentration Per Nuclide........................... 53

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 2 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ A-1 ³ DCF's for external ground radiation, (mrem/yr)/(pCi/g) ³ ³ ³ A-1 ³ Ac-225 (Source: FGR 12) ³ 6.371E-02 ³ 6.371E-02 ³ DCF1( 1)

A-1 ³ Ac-227 (Source: FGR 12) ³ 4.951E-04 ³ 4.951E-04 ³ DCF1( 2)

A-1 ³ Ag-110 (Source: FGR 12) ³ 2.242E-01 ³ 2.242E-01 ³ DCF1( 3)

A-1 ³ Ag-110m (Source: FGR 12) ³ 1.717E+01 ³ 1.717E+01 ³ DCF1( 4)

A-1 ³ Am-241 (Source: FGR 12) ³ 4.372E-02 ³ 4.372E-02 ³ DCF1( 5)

A-1 ³ Am-243 (Source: FGR 12) ³ 1.420E-01 ³ 1.420E-01 ³ DCF1( 6)

A-1 ³ At-217 (Source: FGR 12) ³ 1.773E-03 ³ 1.773E-03 ³ DCF1( 7)

A-1 ³ At-218 (Source: FGR 12) ³ 5.847E-03 ³ 5.847E-03 ³ DCF1( 8)

A-1 ³ Ba-137m (Source: FGR 12) ³ 3.606E+00 ³ 3.606E+00 ³ DCF1( 9)

A-1 ³ Bi-210 (Source: FGR 12) ³ 3.606E-03 ³ 3.606E-03 ³ DCF1( 10)

A-1 ³ Bi-211 (Source: FGR 12) ³ 2.559E-01 ³ 2.559E-01 ³ DCF1( 11)

A-1 ³ Bi-213 (Source: FGR 12) ³ 7.660E-01 ³ 7.660E-01 ³ DCF1( 12)

A-1 ³ Bi-214 (Source: FGR 12) ³ 9.808E+00 ³ 9.808E+00 ³ DCF1( 13)

A-1 ³ C-14 (Source: FGR 12) ³ 1.345E-05 ³ 1.345E-05 ³ DCF1( 14)

A-1 ³ Ce-144 (Source: FGR 12) ³ 7.174E-02 ³ 7.174E-02 ³ DCF1( 15)

A-1 ³ Cm-242 (Source: FGR 12) ³ 1.709E-04 ³ 1.709E-04 ³ DCF1( 16)

A-1 ³ Cm-243 (Source: FGR 12) ³ 5.829E-01 ³ 5.829E-01 ³ DCF1( 17)

A-1 ³ Co-57 (Source: FGR 12) ³ 5.007E-01 ³ 5.007E-01 ³ DCF1( 18)

A-1 ³ Co-58 (Source: FGR 12) ³ 5.960E+00 ³ 5.960E+00 ³ DCF1( 19)

A-1 ³ Co-60 (Source: FGR 12) ³ 1.622E+01 ³ 1.622E+01 ³ DCF1( 20)

A-1 ³ Cs-134 (Source: FGR 12) ³ 9.472E+00 ³ 9.472E+00 ³ DCF1( 21)

A-1 ³ Cs-137 (Source: FGR 12) ³ 7.510E-04 ³ 7.510E-04 ³ DCF1( 22)

A-1 ³ Eu-154 (Source: FGR 12) ³ 7.678E+00 ³ 7.678E+00 ³ DCF1( 23)

A-1 ³ Fe-55 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 24)

A-1 ³ Fr-221 (Source: FGR 12) ³ 1.536E-01 ³ 1.536E-01 ³ DCF1( 25)

A-1 ³ Fr-223 (Source: FGR 12) ³ 1.980E-01 ³ 1.980E-01 ³ DCF1( 26)

A-1 ³ H-3 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 27)

A-1 ³ I-129 (Source: FGR 12) ³ 1.295E-02 ³ 1.295E-02 ³ DCF1( 28)

A-1 ³ In-113m (Source: FGR 12) ³ 1.435E+00 ³ 1.435E+00 ³ DCF1( 29)

A-1 ³ Mn-54 (Source: FGR 12) ³ 5.156E+00 ³ 5.156E+00 ³ DCF1( 30)

A-1 ³ Nb-94 (Source: FGR 12) ³ 9.677E+00 ³ 9.677E+00 ³ DCF1( 31)

A-1 ³ Nb-95 (Source: FGR 12) ³ 4.689E+00 ³ 4.689E+00 ³ DCF1( 32)

A-1 ³ Nb-95m (Source: FGR 12) ³ 3.195E-01 ³ 3.195E-01 ³ DCF1( 33)

A-1 ³ Ni-59 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 34)

A-1 ³ Ni-63 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 35)

A-1 ³ Np-237 (Source: FGR 12) ³ 7.790E-02 ³ 7.790E-02 ³ DCF1( 36)

A-1 ³ Np-239 (Source: FGR 12) ³ 7.529E-01 ³ 7.529E-01 ³ DCF1( 37)

A-1 ³ Pa-231 (Source: FGR 12) ³ 1.906E-01 ³ 1.906E-01 ³ DCF1( 38)

A-1 ³ Pa-233 (Source: FGR 12) ³ 1.020E+00 ³ 1.020E+00 ³ DCF1( 39)

A-1 ³ Pa-234 (Source: FGR 12) ³ 1.155E+01 ³ 1.155E+01 ³ DCF1( 40)

A-1 ³ Pa-234m (Source: FGR 12) ³ 8.967E-02 ³ 8.967E-02 ³ DCF1( 41)

A-1 ³ Pb-209 (Source: FGR 12) ³ 7.734E-04 ³ 7.734E-04 ³ DCF1( 42)

A-1 ³ Pb-210 (Source: FGR 12) ³ 2.447E-03 ³ 2.447E-03 ³ DCF1( 43)

A-1 ³ Pb-211 (Source: FGR 12) ³ 3.064E-01 ³ 3.064E-01 ³ DCF1( 44)

A-1 ³ Pb-214 (Source: FGR 12) ³ 1.341E+00 ³ 1.341E+00 ³ DCF1( 45)

A-1 ³ Po-210 (Source: FGR 12) ³ 5.231E-05 ³ 5.231E-05 ³ DCF1( 46)

A-1 ³ Po-211 (Source: FGR 12) ³ 4.764E-02 ³ 4.764E-02 ³ DCF1( 47)

A-1 ³ Po-213 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 48)

A-1 ³ Po-214 (Source: FGR 12) ³ 5.138E-04 ³ 5.138E-04 ³ DCF1( 49)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 3 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ A-1 ³ Po-215 (Source: FGR 12) ³ 1.016E-03 ³ 1.016E-03 ³ DCF1( 50)

A-1 ³ Po-218 (Source: FGR 12) ³ 5.642E-05 ³ 5.642E-05 ³ DCF1( 51)

A-1 ³ Pr-144 (Source: FGR 12) ³ 2.522E-01 ³ 2.522E-01 ³ DCF1( 52)

A-1 ³ Pr-144m (Source: FGR 12) ³ 1.437E-02 ³ 1.437E-02 ³ DCF1( 53)

A-1 ³ Pu-238 (Source: FGR 12) ³ 1.513E-04 ³ 1.513E-04 ³ DCF1( 54)

A-1 ³ Pu-239 (Source: FGR 12) ³ 2.952E-04 ³ 2.952E-04 ³ DCF1( 55)

A-1 ³ Pu-241 (Source: FGR 12) ³ 5.904E-06 ³ 5.904E-06 ³ DCF1( 56)

A-1 ³ Pu-242 (Source: FGR 12) ³ 1.280E-04 ³ 1.280E-04 ³ DCF1( 57)

A-1 ³ Ra-223 (Source: FGR 12) ³ 6.034E-01 ³ 6.034E-01 ³ DCF1( 58)

A-1 ³ Ra-225 (Source: FGR 12) ³ 1.102E-02 ³ 1.102E-02 ³ DCF1( 59)

A-1 ³ Ra-226 (Source: FGR 12) ³ 3.176E-02 ³ 3.176E-02 ³ DCF1( 60)

A-1 ³ Rh-106 (Source: FGR 12) ³ 1.291E+00 ³ 1.291E+00 ³ DCF1( 61)

A-1 ³ Rn-219 (Source: FGR 12) ³ 3.083E-01 ³ 3.083E-01 ³ DCF1( 62)

A-1 ³ Rn-222 (Source: FGR 12) ³ 2.354E-03 ³ 2.354E-03 ³ DCF1( 63)

A-1 ³ Ru-106 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 64)

A-1 ³ Sb-124 (Source: FGR 12) ³ 1.169E+01 ³ 1.169E+01 ³ DCF1( 65)

A-1 ³ Sb-125 (Source: FGR 12) ³ 2.447E+00 ³ 2.447E+00 ³ DCF1( 66)

A-1 ³ Sn-113 (Source: FGR 12) ³ 2.970E-02 ³ 2.970E-02 ³ DCF1( 67)

A-1 ³ Sr-90 (Source: FGR 12) ³ 7.043E-04 ³ 7.043E-04 ³ DCF1( 68)

A-1 ³ Tc-99 (Source: FGR 12) ³ 1.255E-04 ³ 1.255E-04 ³ DCF1( 69)

A-1 ³ Te-125m (Source: FGR 12) ³ 1.515E-02 ³ 1.515E-02 ³ DCF1( 70)

A-1 ³ Th-227 (Source: FGR 12) ³ 5.212E-01 ³ 5.212E-01 ³ DCF1( 71)

A-1 ³ Th-229 (Source: FGR 12) ³ 3.213E-01 ³ 3.213E-01 ³ DCF1( 72)

A-1 ³ Th-230 (Source: FGR 12) ³ 1.209E-03 ³ 1.209E-03 ³ DCF1( 73)

A-1 ³ Th-231 (Source: FGR 12) ³ 3.643E-02 ³ 3.643E-02 ³ DCF1( 74)

A-1 ³ Th-234 (Source: FGR 12) ³ 2.410E-02 ³ 2.410E-02 ³ DCF1( 75)

A-1 ³ Tl-207 (Source: FGR 12) ³ 1.980E-02 ³ 1.980E-02 ³ DCF1( 76)

A-1 ³ Tl-209 (Source: FGR 12) ³ 1.293E+01 ³ 1.293E+01 ³ DCF1( 77)

A-1 ³ Tl-210 (Source: no data) ³ 0.000E+00 ³-2.000E+00 ³ DCF1( 78)

A-1 ³ U-233 (Source: FGR 12) ³ 1.397E-03 ³ 1.397E-03 ³ DCF1( 79)

A-1 ³ U-234 (Source: FGR 12) ³ 4.017E-04 ³ 4.017E-04 ³ DCF1( 80)

A-1 ³ U-235 (Source: FGR 12) ³ 7.211E-01 ³ 7.211E-01 ³ DCF1( 81)

A-1 ³ U-237 (Source: FGR 12) ³ 5.306E-01 ³ 5.306E-01 ³ DCF1( 82)

A-1 ³ U-238 (Source: FGR 12) ³ 1.031E-04 ³ 1.031E-04 ³ DCF1( 83)

A-1 ³ Y-90 (Source: FGR 12) ³ 2.391E-02 ³ 2.391E-02 ³ DCF1( 84)

A-1 ³ Zn-65 (Source: FGR 12) ³ 3.699E+00 ³ 3.699E+00 ³ DCF1( 85)

A-1 ³ Zr-95 (Source: FGR 12) ³ 4.521E+00 ³ 4.521E+00 ³ DCF1( 86)

³ ³ ³ ³ B-1 ³ Dose conversion factors for inhalation, mrem/pCi: ³ ³ ³ B-1 ³ Ac-227+D ³ 6.724E+00 ³ 6.700E+00 ³ DCF2( 1)

B-1 ³ Ag-110m+D ³ 8.030E-05 ³ 8.030E-05 ³ DCF2( 2)

B-1 ³ Am-241 ³ 4.440E-01 ³ 4.440E-01 ³ DCF2( 3)

B-1 ³ Am-243+D ³ 4.400E-01 ³ 4.400E-01 ³ DCF2( 4)

B-1 ³ C-14(p) (Class: ORGANIC) ³ 2.090E-06 ³ 2.090E-06 ³ DCF2( 5)

B-1 ³ C-14(g) (Class: CO2) ³ 2.350E-08 ³ 2.350E-08 ³ C14GInhDCF B-1 ³ Ce-144+D ³ 3.740E-04 ³ 3.740E-04 ³ DCF2( 6)

B-1 ³ Cm-242 ³ 1.730E-02 ³ 1.730E-02 ³ DCF2( 7)

B-1 ³ Cm-243 ³ 3.070E-01 ³ 3.070E-01 ³ DCF2( 10)

B-1 ³ Co-57 ³ 9.070E-06 ³ 9.070E-06 ³ DCF2( 12)

B-1 ³ Co-58 ³ 1.090E-05 ³ 1.090E-05 ³ DCF2( 13)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 4 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ B-1 ³ Co-60 ³ 2.190E-04 ³ 2.190E-04 ³ DCF2( 14)

B-1 ³ Cs-134 ³ 4.620E-05 ³ 4.620E-05 ³ DCF2( 15)

B-1 ³ Cs-137+D ³ 3.190E-05 ³ 3.190E-05 ³ DCF2( 16)

B-1 ³ Eu-154 ³ 2.860E-04 ³ 2.860E-04 ³ DCF2( 17)

B-1 ³ Fe-55 ³ 2.690E-06 ³ 2.690E-06 ³ DCF2( 18)

B-1 ³ H-3 ³ 6.400E-08 ³ 6.400E-08 ³ DCF2( 19)

B-1 ³ I-129 ³ 1.740E-04 ³ 1.740E-04 ³ DCF2( 20)

B-1 ³ Mn-54 ³ 6.700E-06 ³ 6.700E-06 ³ DCF2( 21)

B-1 ³ Nb-94 ³ 4.140E-04 ³ 4.140E-04 ³ DCF2( 22)

B-1 ³ Nb-95 ³ 5.810E-06 ³ 5.810E-06 ³ DCF2( 23)

B-1 ³ Ni-59 ³ 2.700E-06 ³ 2.700E-06 ³ DCF2( 24)

B-1 ³ Ni-63 ³ 6.290E-06 ³ 6.290E-06 ³ DCF2( 25)

B-1 ³ Np-237+D ³ 5.400E-01 ³ 5.400E-01 ³ DCF2( 26)

B-1 ³ Pa-231 ³ 1.280E+00 ³ 1.280E+00 ³ DCF2( 27)

B-1 ³ Pb-210+D ³ 1.380E-02 ³ 1.360E-02 ³ DCF2( 28)

B-1 ³ Po-210 ³ 9.400E-03 ³ 9.400E-03 ³ DCF2( 29)

B-1 ³ Pu-238 ³ 3.920E-01 ³ 3.920E-01 ³ DCF2( 30)

B-1 ³ Pu-239 ³ 4.290E-01 ³ 4.290E-01 ³ DCF2( 32)

B-1 ³ Pu-241 ³ 8.250E-03 ³ 8.250E-03 ³ DCF2( 33)

B-1 ³ Pu-241+D ³ 8.254E-03 ³ 8.250E-03 ³ DCF2( 34)

B-1 ³ Pu-242 ³ 4.110E-01 ³ 4.110E-01 ³ DCF2( 35)

B-1 ³ Ra-226+D ³ 8.594E-03 ³ 8.580E-03 ³ DCF2( 38)

B-1 ³ Ru-106+D ³ 4.770E-04 ³ 4.770E-04 ³ DCF2( 39)

B-1 ³ Sb-124 ³ 2.520E-05 ³ 2.520E-05 ³ DCF2( 40)

B-1 ³ Sb-125 ³ 1.220E-05 ³ 1.220E-05 ³ DCF2( 41)

B-1 ³ Sn-113+D ³ 1.074E-05 ³ 1.070E-05 ³ DCF2( 43)

B-1 ³ Sr-90+D ³ 1.308E-03 ³ 1.300E-03 ³ DCF2( 44)

B-1 ³ Tc-99 ³ 8.320E-06 ³ 8.320E-06 ³ DCF2( 45)

B-1 ³ Te-125m ³ 7.290E-06 ³ 7.290E-06 ³ DCF2( 46)

B-1 ³ Th-229+D ³ 2.169E+00 ³ 2.150E+00 ³ DCF2( 47)

B-1 ³ Th-230 ³ 3.260E-01 ³ 3.260E-01 ³ DCF2( 48)

B-1 ³ U-233 ³ 1.350E-01 ³ 1.350E-01 ³ DCF2( 49)

B-1 ³ U-234 ³ 1.320E-01 ³ 1.320E-01 ³ DCF2( 50)

B-1 ³ U-235+D ³ 1.230E-01 ³ 1.230E-01 ³ DCF2( 51)

B-1 ³ U-238 ³ 1.180E-01 ³ 1.180E-01 ³ DCF2( 52)

B-1 ³ U-238+D ³ 1.180E-01 ³ 1.180E-01 ³ DCF2( 53)

B-1 ³ Zn-65 ³ 2.040E-05 ³ 2.040E-05 ³ DCF2( 54)

B-1 ³ Zr-95+D ³ 2.362E-05 ³ 2.360E-05 ³ DCF2( 55)

³ ³ ³ ³ D-1 ³ Dose conversion factors for ingestion, mrem/pCi: ³ ³ ³ D-1 ³ Ac-227+D ³ 1.480E-02 ³ 1.410E-02 ³ DCF3( 1)

D-1 ³ Ag-110m+D ³ 1.080E-05 ³ 1.080E-05 ³ DCF3( 2)

D-1 ³ Am-241 ³ 3.640E-03 ³ 3.640E-03 ³ DCF3( 3)

D-1 ³ Am-243+D ³ 3.623E-03 ³ 3.620E-03 ³ DCF3( 4)

D-1 ³ C-14 ³ 2.090E-06 ³ 2.090E-06 ³ DCF3( 5)

D-1 ³ Ce-144+D ³ 2.112E-05 ³ 2.100E-05 ³ DCF3( 6)

D-1 ³ Cm-242 ³ 1.150E-04 ³ 1.150E-04 ³ DCF3( 7)

D-1 ³ Cm-243 ³ 2.510E-03 ³ 2.510E-03 ³ DCF3( 10)

D-1 ³ Co-57 ³ 1.180E-06 ³ 1.180E-06 ³ DCF3( 12)

D-1 ³ Co-58 ³ 3.580E-06 ³ 3.580E-06 ³ DCF3( 13)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 5 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-1 ³ Co-60 ³ 2.690E-05 ³ 2.690E-05 ³ DCF3( 14)

D-1 ³ Cs-134 ³ 7.330E-05 ³ 7.330E-05 ³ DCF3( 15)

D-1 ³ Cs-137+D ³ 5.000E-05 ³ 5.000E-05 ³ DCF3( 16)

D-1 ³ Eu-154 ³ 9.550E-06 ³ 9.550E-06 ³ DCF3( 17)

D-1 ³ Fe-55 ³ 6.070E-07 ³ 6.070E-07 ³ DCF3( 18)

D-1 ³ H-3 ³ 6.400E-08 ³ 6.400E-08 ³ DCF3( 19)

D-1 ³ I-129 ³ 2.760E-04 ³ 2.760E-04 ³ DCF3( 20)

D-1 ³ Mn-54 ³ 2.770E-06 ³ 2.770E-06 ³ DCF3( 21)

D-1 ³ Nb-94 ³ 7.140E-06 ³ 7.140E-06 ³ DCF3( 22)

D-1 ³ Nb-95 ³ 2.570E-06 ³ 2.570E-06 ³ DCF3( 23)

D-1 ³ Ni-59 ³ 2.100E-07 ³ 2.100E-07 ³ DCF3( 24)

D-1 ³ Ni-63 ³ 5.770E-07 ³ 5.770E-07 ³ DCF3( 25)

D-1 ³ Np-237+D ³ 4.444E-03 ³ 4.440E-03 ³ DCF3( 26)

D-1 ³ Pa-231 ³ 1.060E-02 ³ 1.060E-02 ³ DCF3( 27)

D-1 ³ Pb-210+D ³ 5.376E-03 ³ 5.370E-03 ³ DCF3( 28)

D-1 ³ Po-210 ³ 1.900E-03 ³ 1.900E-03 ³ DCF3( 29)

D-1 ³ Pu-238 ³ 3.200E-03 ³ 3.200E-03 ³ DCF3( 30)

D-1 ³ Pu-239 ³ 3.540E-03 ³ 3.540E-03 ³ DCF3( 32)

D-1 ³ Pu-241 ³ 6.840E-05 ³ 6.840E-05 ³ DCF3( 33)

D-1 ³ Pu-241+D ³ 7.157E-05 ³ 6.840E-05 ³ DCF3( 34)

D-1 ³ Pu-242 ³ 3.360E-03 ³ 3.360E-03 ³ DCF3( 35)

D-1 ³ Ra-226+D ³ 1.321E-03 ³ 1.320E-03 ³ DCF3( 38)

D-1 ³ Ru-106+D ³ 2.740E-05 ³ 2.740E-05 ³ DCF3( 39)

D-1 ³ Sb-124 ³ 1.010E-05 ³ 1.010E-05 ³ DCF3( 40)

D-1 ³ Sb-125 ³ 2.810E-06 ³ 2.810E-06 ³ DCF3( 41)

D-1 ³ Sn-113+D ³ 3.185E-06 ³ 3.080E-06 ³ DCF3( 43)

D-1 ³ Sr-90+D ³ 1.528E-04 ³ 1.420E-04 ³ DCF3( 44)

D-1 ³ Tc-99 ³ 1.460E-06 ³ 1.460E-06 ³ DCF3( 45)

D-1 ³ Te-125m ³ 3.670E-06 ³ 3.670E-06 ³ DCF3( 46)

D-1 ³ Th-229+D ³ 4.027E-03 ³ 3.530E-03 ³ DCF3( 47)

D-1 ³ Th-230 ³ 5.480E-04 ³ 5.480E-04 ³ DCF3( 48)

D-1 ³ U-233 ³ 2.890E-04 ³ 2.890E-04 ³ DCF3( 49)

D-1 ³ U-234 ³ 2.830E-04 ³ 2.830E-04 ³ DCF3( 50)

D-1 ³ U-235+D ³ 2.673E-04 ³ 2.660E-04 ³ DCF3( 51)

D-1 ³ U-238 ³ 2.550E-04 ³ 2.550E-04 ³ DCF3( 52)

D-1 ³ U-238+D ³ 2.687E-04 ³ 2.550E-04 ³ DCF3( 53)

D-1 ³ Zn-65 ³ 1.440E-05 ³ 1.440E-05 ³ DCF3( 54)

D-1 ³ Zr-95+D ³ 3.786E-06 ³ 3.770E-06 ³ DCF3( 55)

³ ³ ³ ³ D-34 ³ Food transfer factors: ³ ³ ³ D-34 ³ Ac-227+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 1,1)

D-34 ³ Ac-227+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 1,2)

D-34 ³ Ac-227+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 1,3)

D-34 ³ ³ ³ ³ D-34 ³ Ag-110m+D, plant/soil concentration ratio, dimensionless ³ 1.500E-01 ³ 1.500E-01 ³ RTF( 2,1)

D-34 ³ Ag-110m+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-03 ³ 3.000E-03 ³ RTF( 2,2)

D-34 ³ Ag-110m+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.500E-02 ³ 2.500E-02 ³ RTF( 2,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 6 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Am-241, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 3,1)

D-34 ³ Am-241, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 3,2)

D-34 ³ Am-241, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 3,3)

D-34 ³ ³ ³ ³ D-34 ³ Am-243+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 4,1)

D-34 ³ Am-243+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 4,2)

D-34 ³ Am-243+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 4,3)

D-34 ³ ³ ³ ³ D-34 ³ C-14, plant/soil concentration ratio, dimensionless ³ 5.500E+00 ³ 5.500E+00 ³ RTF( 5,1)

D-34 ³ C-14, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.100E-02 ³ 3.100E-02 ³ RTF( 5,2)

D-34 ³ C-14, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.200E-02 ³ 1.200E-02 ³ RTF( 5,3)

D-34 ³ ³ ³ ³ D-34 ³ Ce-144+D, plant/soil concentration ratio, dimensionless ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 6,1)

D-34 ³ Ce-144+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 6,2)

D-34 ³ Ce-144+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 6,3)

D-34 ³ ³ ³ ³ D-34 ³ Cm-242, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 7,1)

D-34 ³ Cm-242, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 7,2)

D-34 ³ Cm-242, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 7,3)

D-34 ³ ³ ³ ³ D-34 ³ Cm-243, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 10,1)

D-34 ³ Cm-243, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 10,2)

D-34 ³ Cm-243, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 10,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-57, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 12,1)

D-34 ³ Co-57, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 12,2)

D-34 ³ Co-57, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 12,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-58, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 13,1)

D-34 ³ Co-58, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 13,2)

D-34 ³ Co-58, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 13,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-60, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 14,1)

D-34 ³ Co-60, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 14,2)

D-34 ³ Co-60, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 14,3)

D-34 ³ ³ ³ ³ D-34 ³ Cs-134, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 15,1)

D-34 ³ Cs-134, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 15,2)

D-34 ³ Cs-134, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 15,3)

D-34 ³ ³ ³ ³ D-34 ³ Cs-137+D, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 16,1)

D-34 ³ Cs-137+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 16,2)

D-34 ³ Cs-137+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 16,3)

D-34 ³ ³ ³ ³ D-34 ³ Eu-154, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 17,1)

D-34 ³ Eu-154, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 17,2)

D-34 ³ Eu-154, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 17,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 7 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Fe-55, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 18,1)

D-34 ³ Fe-55, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 18,2)

D-34 ³ Fe-55, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 18,3)

D-34 ³ ³ ³ ³ D-34 ³ H-3, plant/soil concentration ratio, dimensionless ³ 4.800E+00 ³ 4.800E+00 ³ RTF( 19,1)

D-34 ³ H-3, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.200E-02 ³ 1.200E-02 ³ RTF( 19,2)

D-34 ³ H-3, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 19,3)

D-34 ³ ³ ³ ³ D-34 ³ I-129, plant/soil concentration ratio, dimensionless ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 20,1)

D-34 ³ I-129, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 7.000E-03 ³ 7.000E-03 ³ RTF( 20,2)

D-34 ³ I-129, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 20,3)

D-34 ³ ³ ³ ³ D-34 ³ Mn-54, plant/soil concentration ratio, dimensionless ³ 3.000E-01 ³ 3.000E-01 ³ RTF( 21,1)

D-34 ³ Mn-54, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-04 ³ 5.000E-04 ³ RTF( 21,2)

D-34 ³ Mn-54, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 21,3)

D-34 ³ ³ ³ ³ D-34 ³ Nb-94, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 22,1)

D-34 ³ Nb-94, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-07 ³ 3.000E-07 ³ RTF( 22,2)

D-34 ³ Nb-94, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 22,3)

D-34 ³ ³ ³ ³ D-34 ³ Nb-95, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 23,1)

D-34 ³ Nb-95, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-07 ³ 3.000E-07 ³ RTF( 23,2)

D-34 ³ Nb-95, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 23,3)

D-34 ³ ³ ³ ³ D-34 ³ Ni-59, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 24,1)

D-34 ³ Ni-59, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 24,2)

D-34 ³ Ni-59, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 24,3)

D-34 ³ ³ ³ ³ D-34 ³ Ni-63, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 25,1)

D-34 ³ Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 25,2)

D-34 ³ Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 25,3)

D-34 ³ ³ ³ ³ D-34 ³ Np-237+D, plant/soil concentration ratio, dimensionless ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 26,1)

D-34 ³ Np-237+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 26,2)

D-34 ³ Np-237+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 26,3)

D-34 ³ ³ ³ ³ D-34 ³ Pa-231, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 27,1)

D-34 ³ Pa-231, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 27,2)

D-34 ³ Pa-231, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 27,3)

D-34 ³ ³ ³ ³ D-34 ³ Pb-210+D, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 28,1)

D-34 ³ Pb-210+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 8.000E-04 ³ 8.000E-04 ³ RTF( 28,2)

D-34 ³ Pb-210+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 28,3)

D-34 ³ ³ ³ ³ D-34 ³ Po-210, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 29,1)

D-34 ³ Po-210, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 29,2)

D-34 ³ Po-210, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 29,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 8 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Pu-238, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 30,1)

D-34 ³ Pu-238, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 30,2)

D-34 ³ Pu-238, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 30,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-239, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 32,1)

D-34 ³ Pu-239, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 32,2)

D-34 ³ Pu-239, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 32,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-241, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 33,1)

D-34 ³ Pu-241, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 33,2)

D-34 ³ Pu-241, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 33,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-241+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 34,1)

D-34 ³ Pu-241+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 34,2)

D-34 ³ Pu-241+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 34,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-242, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 35,1)

D-34 ³ Pu-242, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 35,2)

D-34 ³ Pu-242, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 35,3)

D-34 ³ ³ ³ ³ D-34 ³ Ra-226+D, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 38,1)

D-34 ³ Ra-226+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 38,2)

D-34 ³ Ra-226+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 38,3)

D-34 ³ ³ ³ ³ D-34 ³ Ru-106+D, plant/soil concentration ratio, dimensionless ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 39,1)

D-34 ³ Ru-106+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 39,2)

D-34 ³ Ru-106+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.300E-06 ³ 3.300E-06 ³ RTF( 39,3)

D-34 ³ ³ ³ ³ D-34 ³ Sb-124, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 40,1)

D-34 ³ Sb-124, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 40,2)

D-34 ³ Sb-124, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 40,3)

D-34 ³ ³ ³ ³ D-34 ³ Sb-125, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 41,1)

D-34 ³ Sb-125, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 41,2)

D-34 ³ Sb-125, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 41,3)

D-34 ³ ³ ³ ³ D-34 ³ Sn-113+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 43,1)

D-34 ³ Sn-113+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 43,2)

D-34 ³ Sn-113+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 43,3)

D-34 ³ ³ ³ ³ D-34 ³ Sr-90+D, plant/soil concentration ratio, dimensionless ³ 3.000E-01 ³ 3.000E-01 ³ RTF( 44,1)

D-34 ³ Sr-90+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 44,2)

D-34 ³ Sr-90+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 44,3)

D-34 ³ ³ ³ ³ D-34 ³ Tc-99, plant/soil concentration ratio, dimensionless ³ 5.000E+00 ³ 5.000E+00 ³ RTF( 45,1)

D-34 ³ Tc-99, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 45,2)

D-34 ³ Tc-99, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 45,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 9 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Te-125m, plant/soil concentration ratio, dimensionless ³ 6.000E-01 ³ 6.000E-01 ³ RTF( 46,1)

D-34 ³ Te-125m, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 7.000E-03 ³ 7.000E-03 ³ RTF( 46,2)

D-34 ³ Te-125m, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-04 ³ 5.000E-04 ³ RTF( 46,3)

D-34 ³ ³ ³ ³ D-34 ³ Th-229+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 47,1)

D-34 ³ Th-229+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 47,2)

D-34 ³ Th-229+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 47,3)

D-34 ³ ³ ³ ³ D-34 ³ Th-230, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 48,1)

D-34 ³ Th-230, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 48,2)

D-34 ³ Th-230, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 48,3)

D-34 ³ ³ ³ ³ D-34 ³ U-233, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 49,1)

D-34 ³ U-233, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 49,2)

D-34 ³ U-233, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 49,3)

D-34 ³ ³ ³ ³ D-34 ³ U-234, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 50,1)

D-34 ³ U-234, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 50,2)

D-34 ³ U-234, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 50,3)

D-34 ³ ³ ³ ³ D-34 ³ U-235+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 51,1)

D-34 ³ U-235+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 51,2)

D-34 ³ U-235+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 51,3)

D-34 ³ ³ ³ ³ D-34 ³ U-238, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 52,1)

D-34 ³ U-238, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 52,2)

D-34 ³ U-238, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 52,3)

D-34 ³ ³ ³ ³ D-34 ³ U-238+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 53,1)

D-34 ³ U-238+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 53,2)

D-34 ³ U-238+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 53,3)

D-34 ³ ³ ³ ³ D-34 ³ Zn-65, plant/soil concentration ratio, dimensionless ³ 4.000E-01 ³ 4.000E-01 ³ RTF( 54,1)

D-34 ³ Zn-65, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-01 ³ 1.000E-01 ³ RTF( 54,2)

D-34 ³ Zn-65, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 54,3)

D-34 ³ ³ ³ ³ D-34 ³ Zr-95+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 55,1)

D-34 ³ Zr-95+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 55,2)

D-34 ³ Zr-95+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-07 ³ 6.000E-07 ³ RTF( 55,3)

³ ³ ³ ³ D-5 ³ Bioaccumulation factors, fresh water, L/kg: ³ ³ ³ D-5 ³ Ac-227+D, fish ³ 1.500E+01 ³ 1.500E+01 ³ BIOFAC( 1,1)

D-5 ³ Ac-227+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 1,2)

D-5 ³ ³ ³ ³ D-5 ³ Ag-110m+D, fish ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 2,1)

D-5 ³ Ag-110m+D, crustacea and mollusks ³ 7.700E+02 ³ 7.700E+02 ³ BIOFAC( 2,2)

D-5 ³ ³ ³ ³ D-5 ³ Am-241, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 3,1)

D-5 ³ Am-241, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 3,2)

D-5 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 10 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Am-243+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 4,1)

D-5 ³ Am-243+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 4,2)

D-5 ³ ³ ³ ³ D-5 ³ C-14, fish ³ 5.000E+04 ³ 5.000E+04 ³ BIOFAC( 5,1)

D-5 ³ C-14, crustacea and mollusks ³ 9.100E+03 ³ 9.100E+03 ³ BIOFAC( 5,2)

D-5 ³ ³ ³ ³ D-5 ³ Ce-144+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 6,1)

D-5 ³ Ce-144+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 6,2)

D-5 ³ ³ ³ ³ D-5 ³ Cm-242, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 7,1)

D-5 ³ Cm-242, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 7,2)

D-5 ³ ³ ³ ³ D-5 ³ Cm-243, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 10,1)

D-5 ³ Cm-243, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 10,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-57, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 12,1)

D-5 ³ Co-57, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 12,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-58, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 13,1)

D-5 ³ Co-58, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 13,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-60, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 14,1)

D-5 ³ Co-60, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 14,2)

D-5 ³ ³ ³ ³ D-5 ³ Cs-134, fish ³ 2.000E+03 ³ 2.000E+03 ³ BIOFAC( 15,1)

D-5 ³ Cs-134, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 15,2)

D-5 ³ ³ ³ ³ D-5 ³ Cs-137+D, fish ³ 2.000E+03 ³ 2.000E+03 ³ BIOFAC( 16,1)

D-5 ³ Cs-137+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 16,2)

D-5 ³ ³ ³ ³ D-5 ³ Eu-154, fish ³ 5.000E+01 ³ 5.000E+01 ³ BIOFAC( 17,1)

D-5 ³ Eu-154, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 17,2)

D-5 ³ ³ ³ ³ D-5 ³ Fe-55, fish ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 18,1)

D-5 ³ Fe-55, crustacea and mollusks ³ 3.200E+03 ³ 3.200E+03 ³ BIOFAC( 18,2)

D-5 ³ ³ ³ ³ D-5 ³ H-3, fish ³ 1.000E+00 ³ 1.000E+00 ³ BIOFAC( 19,1)

D-5 ³ H-3, crustacea and mollusks ³ 1.000E+00 ³ 1.000E+00 ³ BIOFAC( 19,2)

D-5 ³ ³ ³ ³ D-5 ³ I-129, fish ³ 4.000E+01 ³ 4.000E+01 ³ BIOFAC( 20,1)

D-5 ³ I-129, crustacea and mollusks ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 20,2)

D-5 ³ ³ ³ ³ D-5 ³ Mn-54, fish ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 21,1)

D-5 ³ Mn-54, crustacea and mollusks ³ 9.000E+04 ³ 9.000E+04 ³ BIOFAC( 21,2)

D-5 ³ ³ ³ ³ D-5 ³ Nb-94, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 22,1)

D-5 ³ Nb-94, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 22,2)

D-5 ³ ³ ³ ³ D-5 ³ Nb-95, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 23,1)

D-5 ³ Nb-95, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 23,2)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 11 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Ni-59, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 24,1)

D-5 ³ Ni-59, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 24,2)

D-5 ³ ³ ³ ³ D-5 ³ Ni-63, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 25,1)

D-5 ³ Ni-63, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 25,2)

D-5 ³ ³ ³ ³ D-5 ³ Np-237+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 26,1)

D-5 ³ Np-237+D, crustacea and mollusks ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 26,2)

D-5 ³ ³ ³ ³ D-5 ³ Pa-231, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 27,1)

D-5 ³ Pa-231, crustacea and mollusks ³ 1.100E+02 ³ 1.100E+02 ³ BIOFAC( 27,2)

D-5 ³ ³ ³ ³ D-5 ³ Pb-210+D, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 28,1)

D-5 ³ Pb-210+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 28,2)

D-5 ³ ³ ³ ³ D-5 ³ Po-210, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 29,1)

D-5 ³ Po-210, crustacea and mollusks ³ 2.000E+04 ³ 2.000E+04 ³ BIOFAC( 29,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-238, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 30,1)

D-5 ³ Pu-238, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 30,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-239, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 32,1)

D-5 ³ Pu-239, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 32,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-241, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 33,1)

D-5 ³ Pu-241, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 33,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-241+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 34,1)

D-5 ³ Pu-241+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 34,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-242, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 35,1)

D-5 ³ Pu-242, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 35,2)

D-5 ³ ³ ³ ³ D-5 ³ Ra-226+D, fish ³ 5.000E+01 ³ 5.000E+01 ³ BIOFAC( 38,1)

D-5 ³ Ra-226+D, crustacea and mollusks ³ 2.500E+02 ³ 2.500E+02 ³ BIOFAC( 38,2)

D-5 ³ ³ ³ ³ D-5 ³ Ru-106+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 39,1)

D-5 ³ Ru-106+D, crustacea and mollusks ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 39,2)

D-5 ³ ³ ³ ³ D-5 ³ Sb-124, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 40,1)

D-5 ³ Sb-124, crustacea and mollusks ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 40,2)

D-5 ³ ³ ³ ³ D-5 ³ Sb-125, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 41,1)

D-5 ³ Sb-125, crustacea and mollusks ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 41,2)

D-5 ³ ³ ³ ³ D-5 ³ Sn-113+D, fish ³ 3.000E+03 ³ 3.000E+03 ³ BIOFAC( 43,1)

D-5 ³ Sn-113+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 43,2)

D-5 ³ ³ ³ ³ D-5 ³ Sr-90+D, fish ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 44,1)

D-5 ³ Sr-90+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 44,2)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 12 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Tc-99, fish ³ 2.000E+01 ³ 2.000E+01 ³ BIOFAC( 45,1)

D-5 ³ Tc-99, crustacea and mollusks ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 45,2)

D-5 ³ ³ ³ ³ D-5 ³ Te-125m, fish ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 46,1)

D-5 ³ Te-125m, crustacea and mollusks ³ 7.500E+01 ³ 7.500E+01 ³ BIOFAC( 46,2)

D-5 ³ ³ ³ ³ D-5 ³ Th-229+D, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 47,1)

D-5 ³ Th-229+D, crustacea and mollusks ³ 5.000E+02 ³ 5.000E+02 ³ BIOFAC( 47,2)

D-5 ³ ³ ³ ³ D-5 ³ Th-230, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 48,1)

D-5 ³ Th-230, crustacea and mollusks ³ 5.000E+02 ³ 5.000E+02 ³ BIOFAC( 48,2)

D-5 ³ ³ ³ ³ D-5 ³ U-233, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 49,1)

D-5 ³ U-233, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 49,2)

D-5 ³ ³ ³ ³ D-5 ³ U-234, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 50,1)

D-5 ³ U-234, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 50,2)

D-5 ³ ³ ³ ³ D-5 ³ U-235+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 51,1)

D-5 ³ U-235+D, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 51,2)

D-5 ³ ³ ³ ³ D-5 ³ U-238, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 52,1)

D-5 ³ U-238, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 52,2)

D-5 ³ ³ ³ ³ D-5 ³ U-238+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 53,1)

D-5 ³ U-238+D, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 53,2)

D-5 ³ ³ ³ ³ D-5 ³ Zn-65, fish ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 54,1)

D-5 ³ Zn-65, crustacea and mollusks ³ 1.000E+04 ³ 1.000E+04 ³ BIOFAC( 54,2)

D-5 ³ ³ ³ ³ D-5 ³ Zr-95+D, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 55,1)

D-5 ³ Zr-95+D, crustacea and mollusks ³ 6.700E+00 ³ 6.700E+00 ³ BIOFAC( 55,2)

  1. For DCF1(xxx) only, factors are for infinite depth & area. See ETFG table in Ground Pathway of Detailed Report.
  • Base Case means Default.Lib w/o Associate Nuclide contributions.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 13 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R011 ³ Area of contaminated zone (m**2) ³ 1.000E+04 ³ 1.000E+04 ³ --- ³ AREA R011 ³ Thickness of contaminated zone (m) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ THICK0 R011 ³ Fraction of contamination that is submerged ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ SUBMFRACT R011 ³ Length parallel to aquifer flow (m) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ LCZPAQ R011 ³ Basic radiation dose limit (mrem/yr) ³ 2.500E+01 ³ 3.000E+01 ³ --- ³ BRDL R011 ³ Time since placement of material (yr) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ TI R011 ³ Times for calculations (yr) ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ T( 2)

R011 ³ Times for calculations (yr) ³ 3.000E+00 ³ 3.000E+00 ³ --- ³ T( 3)

R011 ³ Times for calculations (yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ T( 4)

R011 ³ Times for calculations (yr) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ T( 5)

R011 ³ Times for calculations (yr) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ T( 6)

R011 ³ Times for calculations (yr) ³ 3.000E+02 ³ 3.000E+02 ³ --- ³ T( 7)

R011 ³ Times for calculations (yr) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ T( 8)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ --- ³ T( 9)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ --- ³ T(10)

³ ³ ³ ³ ³ R012 ³ Initial principal radionuclide (pCi/g): Ag-110m ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(2)

R012 ³ Initial principal radionuclide (pCi/g): Am-241 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(3)

R012 ³ Initial principal radionuclide (pCi/g): C-14 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(5)

R012 ³ Initial principal radionuclide (pCi/g): Ce-144 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(6)

R012 ³ Initial principal radionuclide (pCi/g): Cm-242 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(7)

R012 ³ Initial principal radionuclide (pCi/g): Cm-243 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(10)

R012 ³ Initial principal radionuclide (pCi/g): Co-57 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(12)

R012 ³ Initial principal radionuclide (pCi/g): Co-58 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(13)

R012 ³ Initial principal radionuclide (pCi/g): Co-60 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(14)

R012 ³ Initial principal radionuclide (pCi/g): Cs-134 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(15)

R012 ³ Initial principal radionuclide (pCi/g): Cs-137 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(16)

R012 ³ Initial principal radionuclide (pCi/g): Eu-154 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(17)

R012 ³ Initial principal radionuclide (pCi/g): Fe-55 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(18)

R012 ³ Initial principal radionuclide (pCi/g): H-3 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(19)

R012 ³ Initial principal radionuclide (pCi/g): I-129 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(20)

R012 ³ Initial principal radionuclide (pCi/g): Mn-54 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(21)

R012 ³ Initial principal radionuclide (pCi/g): Nb-94 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(22)

R012 ³ Initial principal radionuclide (pCi/g): Ni-59 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(24)

R012 ³ Initial principal radionuclide (pCi/g): Ni-63 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(25)

R012 ³ Initial principal radionuclide (pCi/g): Np-237 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(26)

R012 ³ Initial principal radionuclide (pCi/g): Pu-238 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(30)

R012 ³ Initial principal radionuclide (pCi/g): Pu-239 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(32)

R012 ³ Initial principal radionuclide (pCi/g): Pu-241 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(33)

R012 ³ Initial principal radionuclide (pCi/g): Pu-242 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(35)

R012 ³ Initial principal radionuclide (pCi/g): Ru-106 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(39)

R012 ³ Initial principal radionuclide (pCi/g): Sb-124 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(40)

R012 ³ Initial principal radionuclide (pCi/g): Sb-125 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(41)

R012 ³ Initial principal radionuclide (pCi/g): Sn-113 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(43)

R012 ³ Initial principal radionuclide (pCi/g): Sr-90 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(44)

R012 ³ Initial principal radionuclide (pCi/g): Tc-99 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(45)

R012 ³ Initial principal radionuclide (pCi/g): Zn-65 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(54)

R012 ³ Initial principal radionuclide (pCi/g): Zr-95 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(55)

R012 ³ Concentration in groundwater (pCi/L): Ag-110m ³ not used ³ 0.000E+00 ³ --- ³ W1( 2)

R012 ³ Concentration in groundwater (pCi/L): Am-241 ³ not used ³ 0.000E+00 ³ --- ³ W1( 3)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 14 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R012 ³ Concentration in groundwater (pCi/L): C-14 ³ not used ³ 0.000E+00 ³ --- ³ W1( 5)

R012 ³ Concentration in groundwater (pCi/L): Ce-144 ³ not used ³ 0.000E+00 ³ --- ³ W1( 6)

R012 ³ Concentration in groundwater (pCi/L): Cm-242 ³ not used ³ 0.000E+00 ³ --- ³ W1( 7)

R012 ³ Concentration in groundwater (pCi/L): Cm-243 ³ not used ³ 0.000E+00 ³ --- ³ W1(10)

R012 ³ Concentration in groundwater (pCi/L): Co-57 ³ not used ³ 0.000E+00 ³ --- ³ W1(12)

R012 ³ Concentration in groundwater (pCi/L): Co-58 ³ not used ³ 0.000E+00 ³ --- ³ W1(13)

R012 ³ Concentration in groundwater (pCi/L): Co-60 ³ not used ³ 0.000E+00 ³ --- ³ W1(14)

R012 ³ Concentration in groundwater (pCi/L): Cs-134 ³ not used ³ 0.000E+00 ³ --- ³ W1(15)

R012 ³ Concentration in groundwater (pCi/L): Cs-137 ³ not used ³ 0.000E+00 ³ --- ³ W1(16)

R012 ³ Concentration in groundwater (pCi/L): Eu-154 ³ not used ³ 0.000E+00 ³ --- ³ W1(17)

R012 ³ Concentration in groundwater (pCi/L): Fe-55 ³ not used ³ 0.000E+00 ³ --- ³ W1(18)

R012 ³ Concentration in groundwater (pCi/L): H-3 ³ not used ³ 0.000E+00 ³ --- ³ W1(19)

R012 ³ Concentration in groundwater (pCi/L): I-129 ³ not used ³ 0.000E+00 ³ --- ³ W1(20)

R012 ³ Concentration in groundwater (pCi/L): Mn-54 ³ not used ³ 0.000E+00 ³ --- ³ W1(21)

R012 ³ Concentration in groundwater (pCi/L): Nb-94 ³ not used ³ 0.000E+00 ³ --- ³ W1(22)

R012 ³ Concentration in groundwater (pCi/L): Ni-59 ³ not used ³ 0.000E+00 ³ --- ³ W1(24)

R012 ³ Concentration in groundwater (pCi/L): Ni-63 ³ not used ³ 0.000E+00 ³ --- ³ W1(25)

R012 ³ Concentration in groundwater (pCi/L): Np-237 ³ not used ³ 0.000E+00 ³ --- ³ W1(26)

R012 ³ Concentration in groundwater (pCi/L): Pu-238 ³ not used ³ 0.000E+00 ³ --- ³ W1(30)

R012 ³ Concentration in groundwater (pCi/L): Pu-239 ³ not used ³ 0.000E+00 ³ --- ³ W1(32)

R012 ³ Concentration in groundwater (pCi/L): Pu-241 ³ not used ³ 0.000E+00 ³ --- ³ W1(33)

R012 ³ Concentration in groundwater (pCi/L): Pu-242 ³ not used ³ 0.000E+00 ³ --- ³ W1(35)

R012 ³ Concentration in groundwater (pCi/L): Ru-106 ³ not used ³ 0.000E+00 ³ --- ³ W1(39)

R012 ³ Concentration in groundwater (pCi/L): Sb-124 ³ not used ³ 0.000E+00 ³ --- ³ W1(40)

R012 ³ Concentration in groundwater (pCi/L): Sb-125 ³ not used ³ 0.000E+00 ³ --- ³ W1(41)

R012 ³ Concentration in groundwater (pCi/L): Sn-113 ³ not used ³ 0.000E+00 ³ --- ³ W1(43)

R012 ³ Concentration in groundwater (pCi/L): Sr-90 ³ not used ³ 0.000E+00 ³ --- ³ W1(44)

R012 ³ Concentration in groundwater (pCi/L): Tc-99 ³ not used ³ 0.000E+00 ³ --- ³ W1(45)

R012 ³ Concentration in groundwater (pCi/L): Zn-65 ³ not used ³ 0.000E+00 ³ --- ³ W1(54)

R012 ³ Concentration in groundwater (pCi/L): Zr-95 ³ not used ³ 0.000E+00 ³ --- ³ W1(55)

³ ³ ³ ³ ³ R013 ³ Cover depth (m) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ COVER0 R013 ³ Density of cover material (g/cm**3) ³ not used ³ 1.500E+00 ³ --- ³ DENSCV R013 ³ Cover depth erosion rate (m/yr) ³ not used ³ 1.000E-03 ³ --- ³ VCV R013 ³ Density of contaminated zone (g/cm**3) ³ 1.440E+00 ³ 1.500E+00 ³ --- ³ DENSCZ R013 ³ Contaminated zone erosion rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ --- ³ VCZ R013 ³ Contaminated zone total porosity ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ TPCZ R013 ³ Contaminated zone field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCCZ R013 ³ Contaminated zone hydraulic conductivity (m/yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ HCCZ R013 ³ Contaminated zone b parameter ³ 4.380E+00 ³ 5.300E+00 ³ --- ³ BCZ R013 ³ Average annual wind speed (m/sec) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ WIND R013 ³ Humidity in air (g/m**3) ³ 8.000E+00 ³ 8.000E+00 ³ --- ³ HUMID R013 ³ Evapotranspiration coefficient ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ EVAPTR R013 ³ Precipitation (m/yr) ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ PRECIP R013 ³ Irrigation (m/yr) ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ RI R013 ³ Irrigation mode ³ overhead ³ overhead ³ --- ³ IDITCH R013 ³ Runoff coefficient ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ RUNOFF R013 ³ Watershed area for nearby stream or pond (m**2) ³ 1.000E+06 ³ 1.000E+06 ³ --- ³ WAREA R013 ³ Accuracy for water/soil computations ³ 1.000E-03 ³ 1.000E-03 ³ Romberg failures occurred ³ EPS

³ ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 15 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R014 ³ Density of saturated zone (g/cm**3) ³ 1.500E+00 ³ 1.500E+00 ³ --- ³ DENSAQ R014 ³ Saturated zone total porosity ³ 3.400E-01 ³ 4.000E-01 ³ --- ³ TPSZ R014 ³ Saturated zone effective porosity ³ 2.700E-01 ³ 2.000E-01 ³ --- ³ EPSZ R014 ³ Saturated zone field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCSZ R014 ³ Saturated zone hydraulic conductivity (m/yr) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ HCSZ R014 ³ Saturated zone hydraulic gradient ³ 2.000E-02 ³ 2.000E-02 ³ --- ³ HGWT R014 ³ Saturated zone b parameter ³ 4.050E+00 ³ 5.300E+00 ³ --- ³ BSZ R014 ³ Water table drop rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ --- ³ VWT R014 ³ Well pump intake depth (m below water table) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DWIBWT R014 ³ Model: Nondispersion (ND) or Mass-Balance (MB) ³ ND ³ ND ³ --- ³ MODEL R014 ³ Well pumping rate (m**3/yr) ³ 2.500E+02 ³ 2.500E+02 ³ --- ³ UW

³ ³ ³ ³ ³ R015 ³ Number of unsaturated zone strata ³ 1 ³ 1 ³ --- ³ NS R015 ³ Unsat. zone 1, thickness (m) ³ 1.700E+00 ³ 4.000E+00 ³ --- ³ H(1)

R015 ³ Unsat. zone 1, soil density (g/cm**3) ³ 1.440E+00 ³ 1.500E+00 ³ --- ³ DENSUZ(1)

R015 ³ Unsat. zone 1, total porosity ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ TPUZ(1)

R015 ³ Unsat. zone 1, effective porosity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ EPUZ(1)

R015 ³ Unsat. zone 1, field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCUZ(1)

R015 ³ Unsat. zone 1, soil-specific b parameter ³ 4.380E+00 ³ 5.300E+00 ³ --- ³ BUZ(1)

R015 ³ Unsat. zone 1, hydraulic conductivity (m/yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ HCUZ(1)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ag-110m ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC( 2)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU( 2,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS( 2)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH( 2)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 2)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Am-241 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 3)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 3,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 3)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 3)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 3)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for C-14 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC( 5)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU( 5,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS( 5)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH( 5)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 5)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ce-144 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC( 6)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU( 6,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS( 6)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH( 6)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 6)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 16 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Cm-242 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCC( 7)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCU( 7,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCS( 7)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.260E-04 ³ ALEACH( 7)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 7)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cm-243 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCC(10)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCU(10,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCS(10)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.260E-04 ³ ALEACH(10)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(10)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-57 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(12)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(12,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(12)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(12)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(12)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-58 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(13)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(13,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(13)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(13)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(13)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-60 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(14)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(14,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(14)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(14)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(14)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cs-134 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCC(15)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCU(15,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCS(15)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.774E-05 ³ ALEACH(15)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(15)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cs-137 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCC(16)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCU(16,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCS(16)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.774E-05 ³ ALEACH(16)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(16)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 17 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Eu-154 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCC(17)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCU(17,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCS(17)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.104E-04 ³ ALEACH(17)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(17)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Fe-55 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(18)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(18,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(18)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(18)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(18)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for H-3 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(19)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(19,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(19)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(19)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(19)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for I-129 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCC(20)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCU(20,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCS(20)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 5.506E-01 ³ ALEACH(20)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(20)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Mn-54 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCC(21)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCU(21,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCS(21)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.671E-04 ³ ALEACH(21)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(21)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Nb-94 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(22)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(22,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(22)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(22)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(22)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ni-59 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(24)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(24,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(24)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(24)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(24)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 18 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Ni-63 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(25)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(25,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(25)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(25)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(25)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Np-237 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCC(26)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCU(26,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCS(26)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 6.739E-04 ³ ALEACH(26)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(26)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-238 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(30)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(30,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(30)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(30)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(30)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-239 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(32)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(32,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(32)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(32)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(32)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-241 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(33)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(33,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(33)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(33)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(33)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-242 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(35)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(35,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(35)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(35)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(35)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ru-106 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(39)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(39,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(39)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(39)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(39)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 19 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Sb-124 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(40)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(40,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(40)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(40)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(40)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sb-125 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(41)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(41,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(41)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(41)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(41)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sn-113 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(43)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(43,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(43)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(43)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(43)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sr-90 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCC(44)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCU(44,1)

R016 ³ Saturated zone (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCS(44)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 5.746E-03 ³ ALEACH(44)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(44)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Tc-99 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(45)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(45,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(45)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(45)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(45)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Zn-65 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(54)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(54,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(54)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(54)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(54)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Zr-95 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCC(55)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCU(55,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCS(55)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 7.891E-05 ³ ALEACH(55)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(55)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 20 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for daughter Ac-227 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 1)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 1,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 1)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 1)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 1)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Am-243 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 4)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 4,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 4)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 4)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 4)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Nb-95 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(23)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(23,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(23)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(23)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(23)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Pa-231 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(27)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(27,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(27)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(27)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(27)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Pb-210 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCC(28)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCU(28,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCS(28)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.732E-03 ³ ALEACH(28)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(28)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Po-210 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCC(29)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCU(29,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCS(29)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.700E-02 ³ ALEACH(29)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(29)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Ra-226 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCC(38)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCU(38,1)

R016 ³ Saturated zone (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCS(38)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.473E-03 ³ ALEACH(38)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(38)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 21 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for daughter Te-125m ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(46)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(46,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(46)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(46)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(46)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Th-229 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCC(47)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCU(47,1)

R016 ³ Saturated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCS(47)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.894E-06 ³ ALEACH(47)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(47)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Th-230 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCC(48)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCU(48,1)

R016 ³ Saturated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCS(48)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.894E-06 ³ ALEACH(48)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(48)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-233 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(49)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(49,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(49)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(49)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(49)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-234 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(50)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(50,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(50)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(50)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(50)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-235 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(51)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(51,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(51)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(51)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(51)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-238 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(52)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(52,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(52)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(52)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(52)

R017 ³ Inhalation rate (m**3/yr) ³ 8.400E+03 ³ 8.400E+03 ³ --- ³ INHALR R017 ³ Mass loading for inhalation (g/m**3) ³ 1.000E-04 ³ 1.000E-04 ³ --- ³ MLINH R017 ³ Exposure duration ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ ED R017 ³ Shielding factor, inhalation ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ SHF3

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 22 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R017 ³ Shielding factor, external gamma ³ 7.000E-01 ³ 7.000E-01 ³ --- ³ SHF1 R017 ³ Fraction of time spent indoors ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ FIND R017 ³ Fraction of time spent outdoors (on site) ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ FOTD R017 ³ Shape factor flag, external gamma ³ 1.000E+00 ³ 1.000E+00 ³ >0 shows circular AREA. ³ FS R017 ³ Radii of shape factor array (used if FS = -1): ³ ³ ³ ³ R017 ³ Outer annular radius (m), ring 1: ³ not used ³ 5.000E+01 ³ --- ³ RAD_SHAPE( 1)

R017 ³ Outer annular radius (m), ring 2: ³ not used ³ 7.071E+01 ³ --- ³ RAD_SHAPE( 2)

R017 ³ Outer annular radius (m), ring 3: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 3)

R017 ³ Outer annular radius (m), ring 4: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 4)

R017 ³ Outer annular radius (m), ring 5: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 5)

R017 ³ Outer annular radius (m), ring 6: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 6)

R017 ³ Outer annular radius (m), ring 7: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 7)

R017 ³ Outer annular radius (m), ring 8: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 8)

R017 ³ Outer annular radius (m), ring 9: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 9)

R017 ³ Outer annular radius (m), ring 10: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(10)

R017 ³ Outer annular radius (m), ring 11: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(11)

R017 ³ Outer annular radius (m), ring 12: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(12)

³ ³ ³ ³ ³ R017 ³ Fractions of annular areas within AREA: ³ ³ ³ ³ R017 ³ Ring 1 ³ not used ³ 1.000E+00 ³ --- ³ FRACA( 1)

R017 ³ Ring 2 ³ not used ³ 2.732E-01 ³ --- ³ FRACA( 2)

R017 ³ Ring 3 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 3)

R017 ³ Ring 4 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 4)

R017 ³ Ring 5 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 5)

R017 ³ Ring 6 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 6)

R017 ³ Ring 7 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 7)

R017 ³ Ring 8 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 8)

R017 ³ Ring 9 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 9)

R017 ³ Ring 10 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(10)

R017 ³ Ring 11 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(11)

R017 ³ Ring 12 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(12)

³ ³ ³ ³ ³ R018 ³ Fruits, vegetables and grain consumption (kg/yr) ³ 1.600E+02 ³ 1.600E+02 ³ --- ³ DIET(1)

R018 ³ Leafy vegetable consumption (kg/yr) ³ 1.400E+01 ³ 1.400E+01 ³ --- ³ DIET(2)

R018 ³ Milk consumption (L/yr) ³ 9.200E+01 ³ 9.200E+01 ³ --- ³ DIET(3)

R018 ³ Meat and poultry consumption (kg/yr) ³ 6.300E+01 ³ 6.300E+01 ³ --- ³ DIET(4)

R018 ³ Fish consumption (kg/yr) ³ 5.400E+00 ³ 5.400E+00 ³ --- ³ DIET(5)

R018 ³ Other seafood consumption (kg/yr) ³ 9.000E-01 ³ 9.000E-01 ³ --- ³ DIET(6)

R018 ³ Soil ingestion rate (g/yr) ³ 3.650E+01 ³ 3.650E+01 ³ --- ³ SOIL R018 ³ Drinking water intake (L/yr) ³ 5.100E+02 ³ 5.100E+02 ³ --- ³ DWI R018 ³ Contamination fraction of drinking water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FDW R018 ³ Contamination fraction of household water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FHHW R018 ³ Contamination fraction of livestock water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FLW R018 ³ Contamination fraction of irrigation water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FIRW R018 ³ Contamination fraction of aquatic food ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ FR9 R018 ³ Contamination fraction of plant food ³-1 ³-1 ³ 0.500E+00 ³ FPLANT R018 ³ Contamination fraction of meat ³-1 ³-1 ³ 0.500E+00 ³ FMEAT R018 ³ Contamination fraction of milk ³-1 ³-1 ³ 0.500E+00 ³ FMILK

³ ³ ³ ³ ³ R019 ³ Livestock fodder intake for meat (kg/day) ³ 6.800E+01 ³ 6.800E+01 ³ --- ³ LFI5

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 23 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R019 ³ Livestock fodder intake for milk (kg/day) ³ 5.500E+01 ³ 5.500E+01 ³ --- ³ LFI6 R019 ³ Livestock water intake for meat (L/day) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ LWI5 R019 ³ Livestock water intake for milk (L/day) ³ 1.600E+02 ³ 1.600E+02 ³ --- ³ LWI6 R019 ³ Livestock soil intake (kg/day) ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ LSI R019 ³ Mass loading for foliar deposition (g/m**3) ³ 1.000E-04 ³ 1.000E-04 ³ --- ³ MLFD R019 ³ Depth of soil mixing layer (m) ³ 1.500E-01 ³ 1.500E-01 ³ --- ³ DM R019 ³ Depth of roots (m) ³ 9.000E-01 ³ 9.000E-01 ³ --- ³ DROOT R019 ³ Drinking water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWDW R019 ³ Household water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWHH R019 ³ Livestock water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWLW R019 ³ Irrigation fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWIR

³ ³ ³ ³ ³ R19B ³ Wet weight crop yield for Non-Leafy (kg/m**2) ³ 7.000E-01 ³ 7.000E-01 ³ --- ³ YV(1)

R19B ³ Wet weight crop yield for Leafy (kg/m**2) ³ 1.500E+00 ³ 1.500E+00 ³ --- ³ YV(2)

R19B ³ Wet weight crop yield for Fodder (kg/m**2) ³ 1.100E+00 ³ 1.100E+00 ³ --- ³ YV(3)

R19B ³ Growing Season for Non-Leafy (years) ³ 1.700E-01 ³ 1.700E-01 ³ --- ³ TE(1)

R19B ³ Growing Season for Leafy (years) ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ TE(2)

R19B ³ Growing Season for Fodder (years) ³ 8.000E-02 ³ 8.000E-02 ³ --- ³ TE(3)

R19B ³ Translocation Factor for Non-Leafy ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ TIV(1)

R19B ³ Translocation Factor for Leafy ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ TIV(2)

R19B ³ Translocation Factor for Fodder ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ TIV(3)

R19B ³ Dry Foliar Interception Fraction for Non-Leafy ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RDRY(1)

R19B ³ Dry Foliar Interception Fraction for Leafy ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RDRY(2)

R19B ³ Dry Foliar Interception Fraction for Fodder ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RDRY(3)

R19B ³ Wet Foliar Interception Fraction for Non-Leafy ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RWET(1)

R19B ³ Wet Foliar Interception Fraction for Leafy ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RWET(2)

R19B ³ Wet Foliar Interception Fraction for Fodder ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RWET(3)

R19B ³ Weathering Removal Constant for Vegetation ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ WLAM

³ ³ ³ ³ ³ C14 ³ C-12 concentration in water (g/cm**3) ³ 2.000E-05 ³ 2.000E-05 ³ --- ³ C12WTR C14 ³ C-12 concentration in contaminated soil (g/g) ³ 3.000E-02 ³ 3.000E-02 ³ --- ³ C12CZ C14 ³ Fraction of vegetation carbon from soil ³ 2.000E-02 ³ 2.000E-02 ³ --- ³ CSOIL C14 ³ Fraction of vegetation carbon from air ³ 9.800E-01 ³ 9.800E-01 ³ --- ³ CAIR C14 ³ C-14 evasion layer thickness in soil (m) ³ 3.000E-01 ³ 3.000E-01 ³ --- ³ DMC C14 ³ C-14 evasion flux rate from soil (1/sec) ³ 7.000E-07 ³ 7.000E-07 ³ --- ³ EVSN C14 ³ C-12 evasion flux rate from soil (1/sec) ³ 1.000E-10 ³ 1.000E-10 ³ --- ³ REVSN C14 ³ Fraction of grain in beef cattle feed ³ 8.000E-01 ³ 8.000E-01 ³ --- ³ AVFG4 C14 ³ Fraction of grain in milk cow feed ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ AVFG5

³ ³ ³ ³ ³ STOR ³ Storage times of contaminated foodstuffs (days): ³ ³ ³ ³ STOR ³ Fruits, non-leafy vegetables, and grain ³ 1.400E+01 ³ 1.400E+01 ³ --- ³ STOR_T(1)

STOR ³ Leafy vegetables ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(2)

STOR ³ Milk ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(3)

STOR ³ Meat and poultry ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ STOR_T(4)

STOR ³ Fish ³ 7.000E+00 ³ 7.000E+00 ³ --- ³ STOR_T(5)

STOR ³ Crustacea and mollusks ³ 7.000E+00 ³ 7.000E+00 ³ --- ³ STOR_T(6)

STOR ³ Well water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(7)

STOR ³ Surface water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(8)

STOR ³ Livestock fodder ³ 4.500E+01 ³ 4.500E+01 ³ --- ³ STOR_T(9)

³ ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 24 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R021 ³ Thickness of building foundation (m) ³ 1.500E-01 ³ 1.500E-01 ³ --- ³ FLOOR1 R021 ³ Bulk density of building foundation (g/cm**3) ³ 2.400E+00 ³ 2.400E+00 ³ --- ³ DENSFL R021 ³ Total porosity of the cover material ³ not used ³ 4.000E-01 ³ --- ³ TPCV R021 ³ Total porosity of the building foundation ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ TPFL R021 ³ Volumetric water content of the cover material ³ not used ³ 5.000E-02 ³ --- ³ PH2OCV R021 ³ Volumetric water content of the foundation ³ 3.000E-02 ³ 3.000E-02 ³ --- ³ PH2OFL R021 ³ Diffusion coefficient for radon gas (m/sec): ³ ³ ³ ³ R021 ³ in cover material ³ not used ³ 2.000E-06 ³ --- ³ DIFCV R021 ³ in foundation material ³ 3.000E-07 ³ 3.000E-07 ³ --- ³ DIFFL R021 ³ in contaminated zone soil ³ 2.000E-06 ³ 2.000E-06 ³ --- ³ DIFCZ R021 ³ Radon vertical dimension of mixing (m) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ HMIX R021 ³ Average building air exchange rate (1/hr) ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ REXG R021 ³ Height of the building (room) (m) ³ 2.500E+00 ³ 2.500E+00 ³ --- ³ HRM R021 ³ Building interior area factor ³ 0.000E+00 ³ 0.000E+00 ³ code computed (time dependent) ³ FAI R021 ³ Building depth below ground surface (m) ³-1.000E+00 ³-1.000E+00 ³ code computed (time dependent) ³ DMFL R021 ³ Emanating power of Rn-222 gas ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ EMANA(1)

R021 ³ Emanating power of Rn-220 gas ³ not used ³ 1.500E-01 ³ --- ³ EMANA(2)

³ ³ ³ ³ ³ TITL ³ Number of graphical time points ³ 32 ³ --- ³ --- ³ NPTS TITL ³ Maximum number of integration points for dose ³ 17 ³ --- ³ --- ³ LYMAX TITL ³ Maximum number of integration points for risk ³ 257 ³ --- ³ --- ³ KYMAX

Summary of Pathway Selections Pathway ³ User Selection

Å 1 -- external gamma ³ active 2 -- inhalation (w/o radon)³ active 3 -- plant ingestion ³ active 4 -- meat ingestion ³ active 5 -- milk ingestion ³ active 6 -- aquatic foods ³ active 7 -- drinking water ³ active 8 -- soil ingestion ³ active 9 -- radon ³ active Find peak pathway doses ³ active

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 25 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 10000.00 square meters Ag-110m 1.000E+00 Thickness: 2.00 meters Am-241 1.000E+00 Cover Depth: 0.00 meters C-14 1.000E+00 Ce-144 1.000E+00 Cm-242 1.000E+00 Cm-243 1.000E+00 Co-57 1.000E+00 Co-58 1.000E+00 Co-60 1.000E+00 Cs-134 1.000E+00 Cs-137 1.000E+00 Eu-154 1.000E+00 Fe-55 1.000E+00 H-3 1.000E+00 I-129 1.000E+00 Mn-54 1.000E+00 Nb-94 1.000E+00 Ni-59 1.000E+00 Ni-63 1.000E+00 Np-237 1.000E+00 Pu-238 1.000E+00 Pu-239 1.000E+00 Pu-241 1.000E+00 Pu-242 1.000E+00 Ru-106 1.000E+00 Sb-124 1.000E+00 Sb-125 1.000E+00 Sn-113 1.000E+00 Sr-90 1.000E+00 Tc-99 1.000E+00 Zn-65 1.000E+00 Zr-95 1.000E+00 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 6.029E+01 9.430E+01 1.498E+02 7.111E+01 1.418E+01 1.675E+01 2.091E+01 5.346E+00 M(t): 2.412E+00 3.772E+00 5.993E+00 2.844E+00 5.671E-01 6.701E-01 8.362E-01 2.138E-01 Maximum TDOSE(t): 1.673E+02 mrem/yr at t = 5.49 n 0.01 years

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 26 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 5.489E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Nuclide Ag-110m 2.049E-04 0.0000 1.089E-10 0.0000 0.000E+00 0.0000 3.073E-06 0.0000 2.659E-07 0.0000 2.534E-06 0.0000 6.263E-09 0.0000 Am-241 2.395E-02 0.0001 2.673E-02 0.0002 0.000E+00 0.0000 2.984E-01 0.0018 3.068E-03 0.0000 1.750E-04 0.0000 9.375E-02 0.0006 C-14 2.632E-16 0.0000 1.861E-14 0.0000 0.000E+00 0.0000 1.111E-10 0.0000 4.595E-11 0.0000 1.575E-11 0.0000 1.902E-15 0.0000 Ce-144 9.156E-04 0.0000 1.193E-07 0.0000 0.000E+00 0.0000 1.833E-05 0.0000 4.219E-08 0.0000 1.477E-07 0.0000 2.881E-06 0.0000 Cm-242 4.471E-07 0.0000 1.222E-04 0.0000 7.867E-14 0.0000 1.358E-03 0.0000 2.789E-05 0.0000 3.987E-07 0.0000 4.267E-04 0.0000 Cm-243 2.877E-01 0.0017 1.698E-02 0.0001 0.000E+00 0.0000 1.889E-01 0.0011 7.773E-04 0.0000 1.108E-04 0.0000 5.937E-02 0.0004 Co-57 1.104E-03 0.0000 2.229E-09 0.0000 0.000E+00 0.0000 3.155E-05 0.0000 1.696E-05 0.0000 2.043E-06 0.0000 1.241E-07 0.0000 Co-58 2.717E-09 0.0000 5.663E-16 0.0000 0.000E+00 0.0000 2.026E-11 0.0000 1.088E-11 0.0000 1.310E-12 0.0000 7.956E-14 0.0000 Co-60 4.165E+00 0.0249 6.374E-06 0.0000 0.000E+00 0.0000 8.515E-02 0.0005 4.579E-02 0.0003 5.516E-03 0.0000 3.349E-04 0.0000 Cs-134 7.136E-01 0.0043 3.966E-07 0.0000 0.000E+00 0.0000 3.422E-02 0.0002 2.993E-02 0.0002 9.772E-03 0.0001 2.692E-04 0.0000 Cs-137 1.668E+00 0.0100 1.777E-06 0.0000 0.000E+00 0.0000 1.515E-01 0.0009 1.325E-01 0.0008 4.326E-02 0.0003 1.192E-03 0.0000 Eu-154 2.704E+00 0.0162 1.141E-05 0.0000 0.000E+00 0.0000 1.295E-03 0.0000 2.514E-04 0.0000 8.731E-06 0.0000 1.629E-04 0.0000 Fe-55 0.000E+00 0.0000 3.706E-08 0.0000 0.000E+00 0.0000 1.138E-05 0.0000 4.679E-05 0.0000 1.001E-06 0.0000 3.577E-06 0.0000 H-3 0.000E+00 0.0000 2.784E-08 0.0000 0.000E+00 0.0000 1.095E-06 0.0000 1.953E-07 0.0000 1.593E-07 0.0000 8.764E-11 0.0000 I-129 2.889E-04 0.0000 4.169E-07 0.0000 0.000E+00 0.0000 1.835E-02 0.0001 4.600E-03 0.0000 7.998E-03 0.0000 2.829E-04 0.0000 Mn-54 2.320E-02 0.0001 3.424E-09 0.0000 0.000E+00 0.0000 5.775E-04 0.0000 7.284E-06 0.0000 5.191E-06 0.0000 6.056E-07 0.0000 Nb-94 4.470E-02 0.0003 2.175E-07 0.0000 0.000E+00 0.0000 5.249E-05 0.0000 7.245E-10 0.0000 5.987E-09 0.0000 1.605E-06 0.0000 Ni-59 0.000E+00 0.0000 1.726E-07 0.0000 0.000E+00 0.0000 9.125E-04 0.0000 1.289E-04 0.0000 6.273E-04 0.0000 5.742E-06 0.0000 Ni-63 0.000E+00 0.0000 3.851E-07 0.0000 0.000E+00 0.0000 2.401E-03 0.0000 3.391E-04 0.0000 1.651E-03 0.0000 1.511E-05 0.0000 Np-237 6.217E-01 0.0037 3.442E-02 0.0002 0.000E+00 0.0000 7.701E+00 0.0460 2.594E-01 0.0016 1.629E-03 0.0000 1.212E-01 0.0007 Pu-238 8.560E-05 0.0000 2.391E-02 0.0001 2.087E-11 0.0000 2.657E-01 0.0016 5.461E-03 0.0000 7.800E-05 0.0000 8.351E-02 0.0005 Pu-239 1.688E-04 0.0000 2.743E-02 0.0002 0.000E+00 0.0000 3.081E-01 0.0018 6.333E-03 0.0000 9.036E-05 0.0000 9.684E-02 0.0006 Pu-241 2.138E-04 0.0000 6.251E-04 0.0000 0.000E+00 0.0000 7.026E-03 0.0000 1.183E-04 0.0000 2.811E-06 0.0000 2.208E-03 0.0000 Pu-242 7.541E-05 0.0000 2.629E-02 0.0002 4.929E-21 0.0000 2.925E-01 0.0017 6.012E-03 0.0000 8.578E-05 0.0000 9.193E-02 0.0005 Ru-106 1.036E-04 0.0000 4.351E-09 0.0000 0.000E+00 0.0000 1.049E-05 0.0000 7.081E-07 0.0000 1.380E-09 0.0000 1.069E-07 0.0000 Sb-124 1.473E-12 0.0000 3.607E-19 0.0000 0.000E+00 0.0000 2.028E-15 0.0000 9.313E-17 0.0000 1.154E-17 0.0000 6.184E-17 0.0000 Sb-125 2.578E-03 0.0000 1.671E-09 0.0000 0.000E+00 0.0000 8.202E-05 0.0000 8.763E-06 0.0000 8.856E-07 0.0000 1.893E-07 0.0000 Sn-113 1.794E-08 0.0000 1.484E-14 0.0000 0.000E+00 0.0000 1.541E-11 0.0000 1.558E-11 0.0000 2.068E-12 0.0000 1.883E-12 0.0000 Sr-90 1.162E-02 0.0001 7.016E-05 0.0000 0.000E+00 0.0000 3.342E+00 0.0200 6.750E-01 0.0040 2.004E-01 0.0012 3.505E-03 0.0000 Tc-99 5.917E-07 0.0000 4.372E-09 0.0000 0.000E+00 0.0000 5.367E-03 0.0000 1.484E-05 0.0000 1.681E-04 0.0000 3.282E-07 0.0000 Zn-65 3.824E-05 0.0000 2.391E-11 0.0000 0.000E+00 0.0000 9.447E-06 0.0000 2.652E-05 0.0000 3.015E-06 0.0000 7.218E-09 0.0000 Zr-95 6.601E-10 0.0000 1.986E-16 0.0000 0.000E+00 0.0000 3.597E-13 0.0000 1.097E-17 0.0000 3.934E-17 0.0000 2.091E-14 0.0000 Total 1.027E+01 0.0614 1.566E-01 0.0009 2.095E-11 0.0000 1.271E+01 0.0759 1.170E+00 0.0070 2.716E-01 0.0016 5.550E-01 0.0033

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 27 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 5.489E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Nuclide Ag-110m 1.292E-02 0.0001 9.163E-05 0.0000 0.000E+00 0.0000 1.038E-03 0.0000 4.309E-04 0.0000 7.680E-03 0.0000 2.237E-02 0.0001 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.461E-01 0.0027 C-14 1.479E-01 0.0009 4.115E-01 0.0025 0.000E+00 0.0000 5.898E-02 0.0004 1.282E-02 0.0001 2.101E-02 0.0001 6.522E-01 0.0039 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.371E-04 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.935E-03 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.538E-01 0.0033 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.155E-03 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.750E-09 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.302E+00 0.0257 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.878E-01 0.0047 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.997E+00 0.0119 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.705E+00 0.0162 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.279E-05 0.0000 H-3 1.012E-02 0.0001 6.317E-07 0.0000 0.000E+00 0.0000 9.572E-04 0.0000 2.554E-04 0.0000 6.905E-04 0.0000 1.202E-02 0.0001 I-129 9.812E+01 0.5865 2.120E-01 0.0013 0.000E+00 0.0000 7.573E+00 0.0453 7.320E+00 0.0438 2.295E+01 0.1372 1.362E+02 0.8142 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.379E-02 0.0001 Nb-94 3.413E+00 0.0204 5.757E-02 0.0003 0.000E+00 0.0000 2.658E-01 0.0016 1.150E-05 0.0000 1.628E-04 0.0000 3.781E+00 0.0226 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.675E-03 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.407E-03 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.740E+00 0.0522 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.788E-01 0.0023 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.390E-01 0.0026 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.019E-02 0.0001 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.169E-01 0.0025 Ru-106 2.228E-01 0.0013 7.113E-04 0.0000 0.000E+00 0.0000 1.740E-02 0.0001 4.961E-03 0.0000 1.748E-05 0.0000 2.460E-01 0.0015 Sb-124 1.173E-10 0.0000 6.338E-13 0.0000 0.000E+00 0.0000 9.070E-12 0.0000 1.266E-12 0.0000 2.759E-13 0.0000 1.301E-10 0.0000 Sb-125 3.996E-01 0.0024 3.631E-03 0.0000 0.000E+00 0.0000 3.203E-02 0.0002 9.663E-03 0.0001 1.861E-03 0.0000 4.495E-01 0.0027 Sn-113 3.751E-06 0.0000 6.312E-07 0.0000 0.000E+00 0.0000 2.901E-07 0.0000 4.104E-07 0.0000 8.863E-08 0.0000 5.189E-06 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.233E+00 0.0253 Tc-99 6.980E-01 0.0042 7.746E-04 0.0000 0.000E+00 0.0000 1.203E-01 0.0007 8.644E-04 0.0000 1.759E-02 0.0001 8.431E-01 0.0050 Zn-65 1.488E-02 0.0001 2.111E-03 0.0000 0.000E+00 0.0000 1.265E-03 0.0000 1.662E-02 0.0001 3.548E-03 0.0000 3.850E-02 0.0002 Zr-95 1.006E-11 0.0000 1.602E-13 0.0000 0.000E+00 0.0000 7.099E-13 0.0000 2.069E-17 0.0000 4.082E-16 0.0000 6.714E-10 0.0000 Total 1.030E+02 0.6159 6.884E-01 0.0041 0.000E+00 0.0000 8.071E+00 0.0482 7.366E+00 0.0440 2.301E+01 0.1375 1.673E+02 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 28 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 4.456E+00 0.0739 2.367E-06 0.0000 0.000E+00 0.0000 6.628E-02 0.0011 5.571E-03 0.0001 5.369E-02 0.0009 1.362E-04 0.0000 Am-241 2.533E-02 0.0004 2.827E-02 0.0005 0.000E+00 0.0000 3.155E-01 0.0052 3.243E-03 0.0001 1.850E-04 0.0000 9.914E-02 0.0016 C-14 1.888E-06 0.0000 1.335E-04 0.0000 0.000E+00 0.0000 7.428E-01 0.0123 2.496E-01 0.0041 9.165E-02 0.0015 1.365E-05 0.0000 Ce-144 1.216E-01 0.0020 1.585E-05 0.0000 0.000E+00 0.0000 2.434E-03 0.0000 5.604E-06 0.0000 1.962E-05 0.0000 3.827E-04 0.0000 Cm-242 5.167E-05 0.0000 6.242E-04 0.0000 3.065E-17 0.0000 5.778E-03 0.0001 3.440E-05 0.0000 3.185E-06 0.0000 1.815E-03 0.0000 Cm-243 3.290E-01 0.0055 1.941E-02 0.0003 0.000E+00 0.0000 2.160E-01 0.0036 8.879E-04 0.0000 1.267E-04 0.0000 6.788E-02 0.0011 Co-57 1.867E-01 0.0031 3.771E-07 0.0000 0.000E+00 0.0000 5.337E-03 0.0001 2.869E-03 0.0000 3.456E-04 0.0000 2.099E-05 0.0000 Co-58 9.099E-01 0.0151 1.896E-07 0.0000 0.000E+00 0.0000 6.779E-03 0.0001 3.643E-03 0.0001 4.387E-04 0.0000 2.664E-05 0.0000 Co-60 8.581E+00 0.1423 1.313E-05 0.0000 0.000E+00 0.0000 1.754E-01 0.0029 9.433E-02 0.0016 1.136E-02 0.0002 6.900E-04 0.0000 Cs-134 4.518E+00 0.0749 2.511E-06 0.0000 0.000E+00 0.0000 2.166E-01 0.0036 1.894E-01 0.0031 6.186E-02 0.0010 1.704E-03 0.0000 Cs-137 1.894E+00 0.0314 2.018E-06 0.0000 0.000E+00 0.0000 1.720E-01 0.0029 1.504E-01 0.0025 4.911E-02 0.0008 1.353E-03 0.0000 Eu-154 4.171E+00 0.0692 1.760E-05 0.0000 0.000E+00 0.0000 1.998E-03 0.0000 3.878E-04 0.0000 1.347E-05 0.0000 2.514E-04 0.0000 Fe-55 0.000E+00 0.0000 1.518E-07 0.0000 0.000E+00 0.0000 4.663E-05 0.0000 1.917E-04 0.0000 4.102E-06 0.0000 1.465E-05 0.0000 H-3 0.000E+00 0.0000 2.705E-04 0.0000 0.000E+00 0.0000 1.048E-02 0.0002 1.769E-03 0.0000 1.471E-03 0.0000 8.515E-07 0.0000 I-129 5.933E-03 0.0001 8.563E-06 0.0000 0.000E+00 0.0000 3.755E-01 0.0062 9.316E-02 0.0015 1.628E-01 0.0027 5.810E-03 0.0001 Mn-54 1.990E+00 0.0330 2.937E-07 0.0000 0.000E+00 0.0000 4.953E-02 0.0008 6.247E-04 0.0000 4.452E-04 0.0000 5.195E-05 0.0000 Nb-94 3.737E+00 0.0620 1.819E-05 0.0000 0.000E+00 0.0000 4.364E-03 0.0001 5.939E-08 0.0000 4.952E-07 0.0000 1.342E-04 0.0000 Ni-59 0.000E+00 0.0000 1.728E-07 0.0000 0.000E+00 0.0000 9.134E-04 0.0000 1.290E-04 0.0000 6.279E-04 0.0000 5.748E-06 0.0000 Ni-63 0.000E+00 0.0000 4.010E-07 0.0000 0.000E+00 0.0000 2.501E-03 0.0000 3.532E-04 0.0000 1.719E-03 0.0000 1.574E-05 0.0000 Np-237 6.240E-01 0.0103 3.455E-02 0.0006 0.000E+00 0.0000 7.730E+00 0.1282 2.603E-01 0.0043 1.635E-03 0.0000 1.216E-01 0.0020 Pu-238 8.944E-05 0.0000 2.499E-02 0.0004 2.458E-14 0.0000 2.776E-01 0.0046 5.706E-03 0.0001 8.142E-05 0.0000 8.725E-02 0.0014 Pu-239 1.689E-04 0.0000 2.745E-02 0.0005 0.000E+00 0.0000 3.083E-01 0.0051 6.337E-03 0.0001 9.041E-05 0.0000 9.690E-02 0.0016 Pu-241 3.059E-05 0.0000 5.378E-04 0.0000 0.000E+00 0.0000 6.066E-03 0.0001 1.223E-04 0.0000 1.852E-06 0.0000 1.906E-03 0.0000 Pu-242 7.544E-05 0.0000 2.630E-02 0.0004 7.636E-25 0.0000 2.927E-01 0.0049 6.015E-03 0.0001 8.582E-05 0.0000 9.198E-02 0.0015 Ru-106 3.772E-01 0.0063 1.585E-05 0.0000 0.000E+00 0.0000 3.794E-02 0.0006 2.502E-03 0.0000 4.929E-06 0.0000 3.894E-04 0.0000 Sb-124 1.305E+00 0.0217 3.196E-07 0.0000 0.000E+00 0.0000 1.768E-03 0.0000 7.828E-05 0.0000 9.936E-06 0.0000 5.480E-05 0.0000 Sb-125 8.508E-01 0.0141 5.300E-07 0.0000 0.000E+00 0.0000 1.870E-02 0.0003 1.702E-03 0.0000 1.848E-04 0.0000 5.783E-05 0.0000 Sn-113 2.627E-01 0.0044 2.174E-07 0.0000 0.000E+00 0.0000 2.233E-04 0.0000 2.224E-04 0.0000 3.001E-05 0.0000 2.757E-05 0.0000 Sr-90 1.367E-02 0.0002 8.251E-05 0.0000 0.000E+00 0.0000 3.930E+00 0.0652 7.937E-01 0.0132 2.356E-01 0.0039 4.122E-03 0.0001 Tc-99 4.947E-05 0.0000 3.655E-07 0.0000 0.000E+00 0.0000 4.461E-01 0.0074 1.207E-03 0.0000 1.378E-02 0.0002 2.744E-05 0.0000 Zn-65 9.532E-01 0.0158 5.959E-07 0.0000 0.000E+00 0.0000 2.336E-01 0.0039 6.364E-01 0.0106 7.315E-02 0.0012 1.799E-04 0.0000 Zr-95 1.206E+00 0.0200 4.560E-07 0.0000 0.000E+00 0.0000 5.147E-04 0.0000 2.303E-08 0.0000 5.827E-08 0.0000 4.108E-05 0.0000 Total 3.652E+01 0.6057 1.627E-01 0.0027 2.461E-14 0.0000 1.565E+01 0.2596 2.511E+00 0.0416 7.606E-01 0.0126 5.840E-01 0.0097

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 29 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 1.998E-01 0.0033 1.309E-03 0.0000 0.000E+00 0.0000 1.402E-02 0.0002 3.156E-03 0.0001 9.505E-02 0.0016 4.895E+00 0.0812 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.717E-01 0.0078 C-14 5.850E-02 0.0010 1.509E-01 0.0025 0.000E+00 0.0000 1.956E-02 0.0003 2.708E-03 0.0000 7.640E-03 0.0001 1.324E+00 0.0220 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.245E-01 0.0021 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.306E-03 0.0001 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.333E-01 0.0105 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.953E-01 0.0032 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.207E-01 0.0153 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.862E+00 0.1470 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.987E+00 0.0827 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.267E+00 0.0376 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.174E+00 0.0692 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.572E-04 0.0000 H-3 2.339E-03 0.0000 1.355E-07 0.0000 0.000E+00 0.0000 1.886E-04 0.0000 3.913E-05 0.0000 1.513E-04 0.0000 1.671E-02 0.0003 I-129 1.406E+00 0.0233 2.621E-03 0.0000 0.000E+00 0.0000 8.395E-02 0.0014 2.024E-02 0.0003 2.242E-01 0.0037 2.380E+00 0.0395 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.041E+00 0.0338 Nb-94 3.066E-01 0.0051 4.809E-03 0.0001 0.000E+00 0.0000 2.107E-02 0.0003 5.068E-07 0.0000 1.181E-05 0.0000 4.074E+00 0.0676 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.676E-03 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.589E-03 0.0001 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.772E+00 0.1455 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.957E-01 0.0066 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.393E-01 0.0073 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.665E-03 0.0001 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.171E-01 0.0069 Ru-106 6.634E-01 0.0110 1.962E-03 0.0000 0.000E+00 0.0000 4.547E-02 0.0008 7.085E-03 0.0001 4.181E-05 0.0000 1.136E+00 0.0188 Sb-124 1.443E-02 0.0002 6.999E-05 0.0000 0.000E+00 0.0000 9.366E-04 0.0000 6.284E-05 0.0000 2.613E-05 0.0000 1.323E+00 0.0219 Sb-125 1.277E-01 0.0021 1.065E-03 0.0000 0.000E+00 0.0000 9.003E-03 0.0001 1.480E-03 0.0000 4.728E-04 0.0000 1.011E+00 0.0168 Sn-113 2.236E-02 0.0004 3.447E-03 0.0001 0.000E+00 0.0000 1.494E-03 0.0000 1.103E-03 0.0000 4.180E-04 0.0000 2.920E-01 0.0048 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.978E+00 0.0826 Tc-99 6.270E-02 0.0010 6.469E-05 0.0000 0.000E+00 0.0000 9.374E-03 0.0002 3.728E-05 0.0000 1.252E-03 0.0000 5.346E-01 0.0089 Zn-65 2.609E-01 0.0043 3.420E-02 0.0006 0.000E+00 0.0000 1.935E-02 0.0003 1.378E-01 0.0023 4.973E-02 0.0008 2.399E+00 0.0398 Zr-95 4.097E-04 0.0000 5.842E-06 0.0000 0.000E+00 0.0000 2.426E-05 0.0000 3.457E-10 0.0000 1.342E-08 0.0000 1.207E+00 0.0200 Total 3.125E+00 0.0518 2.005E-01 0.0033 0.000E+00 0.0000 2.244E-01 0.0037 1.737E-01 0.0029 3.790E-01 0.0063 6.029E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 30 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 7.223E-01 0.0077 3.837E-07 0.0000 0.000E+00 0.0000 1.083E-02 0.0001 9.371E-04 0.0000 8.933E-03 0.0001 2.207E-05 0.0000 Am-241 2.507E-02 0.0003 2.798E-02 0.0003 0.000E+00 0.0000 3.124E-01 0.0033 3.211E-03 0.0000 1.832E-04 0.0000 9.813E-02 0.0010 C-14 3.046E-08 0.0000 2.154E-06 0.0000 0.000E+00 0.0000 1.285E-02 0.0001 5.303E-03 0.0001 1.819E-03 0.0000 2.202E-07 0.0000 Ce-144 4.991E-02 0.0005 6.503E-06 0.0000 0.000E+00 0.0000 9.989E-04 0.0000 2.300E-06 0.0000 8.052E-06 0.0000 1.570E-04 0.0000 Cm-242 1.127E-05 0.0000 2.314E-04 0.0000 7.703E-16 0.0000 2.327E-03 0.0000 2.996E-05 0.0000 9.971E-07 0.0000 7.312E-04 0.0000 Cm-243 3.210E-01 0.0034 1.894E-02 0.0002 0.000E+00 0.0000 2.108E-01 0.0022 8.666E-04 0.0000 1.236E-04 0.0000 6.624E-02 0.0007 Co-57 7.332E-02 0.0008 1.481E-07 0.0000 0.000E+00 0.0000 2.096E-03 0.0000 1.127E-03 0.0000 1.357E-04 0.0000 8.242E-06 0.0000 Co-58 2.546E-02 0.0003 5.306E-09 0.0000 0.000E+00 0.0000 1.898E-04 0.0000 1.020E-04 0.0000 1.228E-05 0.0000 7.455E-07 0.0000 Co-60 7.522E+00 0.0798 1.151E-05 0.0000 0.000E+00 0.0000 1.538E-01 0.0016 8.269E-02 0.0009 9.961E-03 0.0001 6.048E-04 0.0000 Cs-134 3.228E+00 0.0342 1.794E-06 0.0000 0.000E+00 0.0000 1.548E-01 0.0016 1.354E-01 0.0014 4.420E-02 0.0005 1.218E-03 0.0000 Cs-137 1.851E+00 0.0196 1.972E-06 0.0000 0.000E+00 0.0000 1.681E-01 0.0018 1.470E-01 0.0016 4.799E-02 0.0005 1.322E-03 0.0000 Eu-154 3.854E+00 0.0409 1.626E-05 0.0000 0.000E+00 0.0000 1.846E-03 0.0000 3.583E-04 0.0000 1.245E-05 0.0000 2.323E-04 0.0000 Fe-55 0.000E+00 0.0000 1.174E-07 0.0000 0.000E+00 0.0000 3.606E-05 0.0000 1.482E-04 0.0000 3.173E-06 0.0000 1.133E-05 0.0000 H-3 0.000E+00 0.0000 5.087E-05 0.0000 0.000E+00 0.0000 2.002E-03 0.0000 3.566E-04 0.0000 2.909E-04 0.0000 1.602E-07 0.0000 I-129 3.421E-03 0.0000 4.937E-06 0.0000 0.000E+00 0.0000 2.173E-01 0.0023 5.448E-02 0.0006 9.472E-02 0.0010 3.350E-03 0.0000 Mn-54 8.844E-01 0.0094 1.305E-07 0.0000 0.000E+00 0.0000 2.201E-02 0.0002 2.777E-04 0.0000 1.979E-04 0.0000 2.309E-05 0.0000 Nb-94 1.669E+00 0.0177 8.120E-06 0.0000 0.000E+00 0.0000 1.959E-03 0.0000 2.705E-08 0.0000 2.235E-07 0.0000 5.990E-05 0.0000 Ni-59 0.000E+00 0.0000 1.727E-07 0.0000 0.000E+00 0.0000 9.133E-04 0.0000 1.290E-04 0.0000 6.278E-04 0.0000 5.747E-06 0.0000 Ni-63 0.000E+00 0.0000 3.981E-07 0.0000 0.000E+00 0.0000 2.482E-03 0.0000 3.506E-04 0.0000 1.706E-03 0.0000 1.562E-05 0.0000 Np-237 6.236E-01 0.0066 3.452E-02 0.0004 0.000E+00 0.0000 7.725E+00 0.0819 2.602E-01 0.0028 1.634E-03 0.0000 1.215E-01 0.0013 Pu-238 8.873E-05 0.0000 2.479E-02 0.0003 3.676E-13 0.0000 2.754E-01 0.0029 5.661E-03 0.0001 8.078E-05 0.0000 8.656E-02 0.0009 Pu-239 1.689E-04 0.0000 2.745E-02 0.0003 0.000E+00 0.0000 3.083E-01 0.0033 6.336E-03 0.0001 9.040E-05 0.0000 9.689E-02 0.0010 Pu-241 6.860E-05 0.0000 5.565E-04 0.0000 0.000E+00 0.0000 6.272E-03 0.0001 1.217E-04 0.0000 2.053E-06 0.0000 1.971E-03 0.0000 Pu-242 7.544E-05 0.0000 2.630E-02 0.0003 2.363E-23 0.0000 2.926E-01 0.0031 6.014E-03 0.0001 8.581E-05 0.0000 9.197E-02 0.0010 Ru-106 8.467E-02 0.0009 3.557E-06 0.0000 0.000E+00 0.0000 8.579E-03 0.0001 5.789E-04 0.0000 1.128E-06 0.0000 8.741E-05 0.0000 Sb-124 8.692E-03 0.0001 2.128E-09 0.0000 0.000E+00 0.0000 1.197E-05 0.0000 5.496E-07 0.0000 6.811E-08 0.0000 3.649E-07 0.0000 Sb-125 2.959E-01 0.0031 1.917E-07 0.0000 0.000E+00 0.0000 9.361E-03 0.0001 9.956E-04 0.0000 1.008E-04 0.0000 2.170E-05 0.0000 Sn-113 1.300E-02 0.0001 1.076E-08 0.0000 0.000E+00 0.0000 1.117E-05 0.0000 1.129E-05 0.0000 1.499E-06 0.0000 1.365E-06 0.0000 Sr-90 1.327E-02 0.0001 8.011E-05 0.0000 0.000E+00 0.0000 3.816E+00 0.0405 7.707E-01 0.0082 2.288E-01 0.0024 4.002E-03 0.0000 Tc-99 2.209E-05 0.0000 1.632E-07 0.0000 0.000E+00 0.0000 2.003E-01 0.0021 5.540E-04 0.0000 6.276E-03 0.0001 1.225E-05 0.0000 Zn-65 1.507E-01 0.0016 9.423E-08 0.0000 0.000E+00 0.0000 3.724E-02 0.0004 1.045E-01 0.0011 1.188E-02 0.0001 2.845E-05 0.0000 Zr-95 3.403E-02 0.0004 1.027E-08 0.0000 0.000E+00 0.0000 1.848E-05 0.0000 5.664E-10 0.0000 2.020E-09 0.0000 1.079E-06 0.0000 Total 2.145E+01 0.2275 1.610E-01 0.0017 3.684E-13 0.0000 1.396E+01 0.1480 1.588E+00 0.0168 4.599E-01 0.0049 5.752E-01 0.0061

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 31 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 6.683E-01 0.0071 4.653E-03 0.0000 0.000E+00 0.0000 5.201E-02 0.0006 1.887E-02 0.0002 3.753E-01 0.0040 1.862E+00 0.0197 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.669E-01 0.0050 C-14 2.146E-01 0.0023 5.837E-01 0.0062 0.000E+00 0.0000 8.126E-02 0.0009 1.566E-02 0.0002 2.966E-02 0.0003 9.448E-01 0.0100 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.108E-02 0.0005 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.332E-03 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.180E-01 0.0066 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.669E-02 0.0008 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.577E-02 0.0003 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.769E+00 0.0824 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.563E+00 0.0378 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.215E+00 0.0235 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.857E+00 0.0409 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.989E-04 0.0000 H-3 1.224E-02 0.0001 7.499E-07 0.0000 0.000E+00 0.0000 1.112E-03 0.0000 2.787E-04 0.0000 8.231E-04 0.0000 1.716E-02 0.0002 I-129 3.338E+01 0.3540 7.076E-02 0.0008 0.000E+00 0.0000 2.494E+00 0.0264 2.067E+00 0.0219 7.349E+00 0.0779 4.573E+01 0.4850 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.069E-01 0.0096 Nb-94 2.058E+00 0.0218 3.409E-02 0.0004 0.000E+00 0.0000 1.554E-01 0.0016 5.891E-06 0.0000 9.281E-05 0.0000 3.918E+00 0.0415 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.676E-03 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.555E-03 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.766E+00 0.0930 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.926E-01 0.0042 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.392E-01 0.0047 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.992E-03 0.0001 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.171E-01 0.0044 Ru-106 2.755E+00 0.0292 8.636E-03 0.0001 0.000E+00 0.0000 2.086E-01 0.0022 5.202E-02 0.0006 2.043E-04 0.0000 3.118E+00 0.0331 Sb-124 8.075E-03 0.0001 4.270E-05 0.0000 0.000E+00 0.0000 6.030E-04 0.0000 7.182E-05 0.0000 1.782E-05 0.0000 1.752E-02 0.0002 Sb-125 7.227E-01 0.0077 6.441E-03 0.0001 0.000E+00 0.0000 5.614E-02 0.0006 1.481E-02 0.0002 3.176E-03 0.0000 1.110E+00 0.0118 Sn-113 3.605E-02 0.0004 5.950E-03 0.0001 0.000E+00 0.0000 2.700E-03 0.0000 3.313E-03 0.0000 8.033E-04 0.0000 6.184E-02 0.0007 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.833E+00 0.0513 Tc-99 4.208E-01 0.0045 4.586E-04 0.0000 0.000E+00 0.0000 7.003E-02 0.0007 4.409E-04 0.0000 9.977E-03 0.0001 7.089E-01 0.0075 Zn-65 8.588E-01 0.0091 1.196E-01 0.0013 0.000E+00 0.0000 7.074E-02 0.0008 8.119E-01 0.0086 1.934E-01 0.0021 2.359E+00 0.0250 Zr-95 3.612E-04 0.0000 5.638E-06 0.0000 0.000E+00 0.0000 2.468E-05 0.0000 6.185E-10 0.0000 1.395E-08 0.0000 3.444E-02 0.0004 Total 4.113E+01 0.4362 8.343E-01 0.0088 0.000E+00 0.0000 3.193E+00 0.0339 2.984E+00 0.0316 7.963E+00 0.0844 9.430E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 32 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 1.899E-02 0.0001 1.008E-08 0.0000 0.000E+00 0.0000 2.847E-04 0.0000 2.463E-05 0.0000 2.348E-04 0.0000 5.801E-07 0.0000 Am-241 2.456E-02 0.0002 2.742E-02 0.0002 0.000E+00 0.0000 3.061E-01 0.0020 3.146E-03 0.0000 1.795E-04 0.0000 9.615E-02 0.0006 C-14 7.850E-12 0.0000 5.551E-10 0.0000 0.000E+00 0.0000 3.312E-06 0.0000 1.368E-06 0.0000 4.692E-07 0.0000 5.673E-11 0.0000 Ce-144 8.405E-03 0.0001 1.095E-06 0.0000 0.000E+00 0.0000 1.682E-04 0.0000 3.873E-07 0.0000 1.356E-06 0.0000 2.645E-05 0.0000 Cm-242 9.279E-07 0.0000 1.292E-04 0.0000 1.340E-14 0.0000 1.425E-03 0.0000 2.849E-05 0.0000 4.321E-07 0.0000 4.478E-04 0.0000 Cm-243 3.057E-01 0.0020 1.804E-02 0.0001 0.000E+00 0.0000 2.007E-01 0.0013 8.256E-04 0.0000 1.177E-04 0.0000 6.309E-02 0.0004 Co-57 1.131E-02 0.0001 2.284E-08 0.0000 0.000E+00 0.0000 3.232E-04 0.0000 1.738E-04 0.0000 2.093E-05 0.0000 1.271E-06 0.0000 Co-58 1.994E-05 0.0000 4.156E-12 0.0000 0.000E+00 0.0000 1.487E-07 0.0000 7.987E-08 0.0000 9.617E-09 0.0000 5.839E-10 0.0000 Co-60 5.780E+00 0.0386 8.846E-06 0.0000 0.000E+00 0.0000 1.182E-01 0.0008 6.354E-02 0.0004 7.655E-03 0.0001 4.648E-04 0.0000 Cs-134 1.648E+00 0.0110 9.158E-07 0.0000 0.000E+00 0.0000 7.902E-02 0.0005 6.910E-02 0.0005 2.256E-02 0.0002 6.216E-04 0.0000 Cs-137 1.767E+00 0.0118 1.883E-06 0.0000 0.000E+00 0.0000 1.605E-01 0.0011 1.403E-01 0.0009 4.582E-02 0.0003 1.262E-03 0.0000 Eu-154 3.291E+00 0.0220 1.389E-05 0.0000 0.000E+00 0.0000 1.577E-03 0.0000 3.060E-04 0.0000 1.063E-05 0.0000 1.983E-04 0.0000 Fe-55 0.000E+00 0.0000 7.024E-08 0.0000 0.000E+00 0.0000 2.157E-05 0.0000 8.868E-05 0.0000 1.898E-06 0.0000 6.780E-06 0.0000 H-3 0.000E+00 0.0000 1.795E-06 0.0000 0.000E+00 0.0000 7.064E-05 0.0000 1.259E-05 0.0000 1.027E-05 0.0000 5.652E-09 0.0000 I-129 1.137E-03 0.0000 1.641E-06 0.0000 0.000E+00 0.0000 7.224E-02 0.0005 1.811E-02 0.0001 3.149E-02 0.0002 1.114E-03 0.0000 Mn-54 1.747E-01 0.0012 2.578E-08 0.0000 0.000E+00 0.0000 4.347E-03 0.0000 5.483E-05 0.0000 3.908E-05 0.0000 4.559E-06 0.0000 Nb-94 3.326E-01 0.0022 1.619E-06 0.0000 0.000E+00 0.0000 3.906E-04 0.0000 5.392E-09 0.0000 4.455E-08 0.0000 1.194E-05 0.0000 Ni-59 0.000E+00 0.0000 1.727E-07 0.0000 0.000E+00 0.0000 9.129E-04 0.0000 1.289E-04 0.0000 6.276E-04 0.0000 5.745E-06 0.0000 Ni-63 0.000E+00 0.0000 3.922E-07 0.0000 0.000E+00 0.0000 2.446E-03 0.0000 3.454E-04 0.0000 1.681E-03 0.0000 1.539E-05 0.0000 Np-237 6.227E-01 0.0042 3.448E-02 0.0002 0.000E+00 0.0000 7.714E+00 0.0515 2.598E-01 0.0017 1.632E-03 0.0000 1.214E-01 0.0008 Pu-238 8.732E-05 0.0000 2.439E-02 0.0002 4.259E-12 0.0000 2.711E-01 0.0018 5.571E-03 0.0000 7.953E-05 0.0000 8.519E-02 0.0006 Pu-239 1.689E-04 0.0000 2.744E-02 0.0002 0.000E+00 0.0000 3.082E-01 0.0021 6.335E-03 0.0000 9.038E-05 0.0000 9.687E-02 0.0006 Pu-241 1.382E-04 0.0000 5.900E-04 0.0000 0.000E+00 0.0000 6.641E-03 0.0000 1.202E-04 0.0000 2.418E-06 0.0000 2.087E-03 0.0000 Pu-242 7.542E-05 0.0000 2.629E-02 0.0002 5.931E-22 0.0000 2.926E-01 0.0020 6.013E-03 0.0000 8.580E-05 0.0000 9.195E-02 0.0006 Ru-106 4.267E-03 0.0000 1.793E-07 0.0000 0.000E+00 0.0000 4.323E-04 0.0000 2.918E-05 0.0000 5.686E-08 0.0000 4.405E-06 0.0000 Sb-124 3.854E-07 0.0000 9.437E-14 0.0000 0.000E+00 0.0000 5.307E-10 0.0000 2.437E-11 0.0000 3.020E-12 0.0000 1.618E-11 0.0000 Sb-125 3.576E-02 0.0002 2.318E-08 0.0000 0.000E+00 0.0000 1.138E-03 0.0000 1.216E-04 0.0000 1.229E-05 0.0000 2.626E-06 0.0000 Sn-113 3.185E-05 0.0000 2.635E-11 0.0000 0.000E+00 0.0000 2.737E-08 0.0000 2.767E-08 0.0000 3.672E-09 0.0000 3.343E-09 0.0000 Sr-90 1.251E-02 0.0001 7.551E-05 0.0000 0.000E+00 0.0000 3.597E+00 0.0240 7.265E-01 0.0048 2.157E-01 0.0014 3.772E-03 0.0000 Tc-99 4.403E-06 0.0000 3.253E-08 0.0000 0.000E+00 0.0000 3.994E-02 0.0003 1.104E-04 0.0000 1.251E-03 0.0000 2.442E-06 0.0000 Zn-65 3.769E-03 0.0000 2.356E-09 0.0000 0.000E+00 0.0000 9.311E-04 0.0000 2.614E-03 0.0000 2.971E-04 0.0000 7.115E-07 0.0000 Zr-95 1.251E-05 0.0000 3.763E-12 0.0000 0.000E+00 0.0000 6.816E-09 0.0000 2.079E-13 0.0000 7.455E-13 0.0000 3.961E-10 0.0000 Total 1.404E+01 0.0937 1.589E-01 0.0011 4.273E-12 0.0000 1.318E+01 0.0880 1.303E+00 0.0087 3.296E-01 0.0022 5.647E-01 0.0038

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 33 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 1.591E-01 0.0011 1.121E-03 0.0000 0.000E+00 0.0000 1.264E-02 0.0001 5.054E-03 0.0000 9.288E-02 0.0006 2.903E-01 0.0019 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.575E-01 0.0031 C-14 2.222E-01 0.0015 6.060E-01 0.0040 0.000E+00 0.0000 8.465E-02 0.0006 1.664E-02 0.0001 3.082E-02 0.0002 9.603E-01 0.0064 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.602E-03 0.0001 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.032E-03 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.885E-01 0.0039 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.183E-02 0.0001 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.018E-05 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.970E+00 0.0398 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.819E+00 0.0121 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.115E+00 0.0141 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.293E+00 0.0220 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.190E-04 0.0000 H-3 1.416E-02 0.0001 8.741E-07 0.0000 0.000E+00 0.0000 1.308E-03 0.0000 3.378E-04 0.0000 9.580E-04 0.0000 1.686E-02 0.0001 I-129 8.059E+01 0.5379 1.738E-01 0.0012 0.000E+00 0.0000 6.198E+00 0.0414 5.898E+00 0.0394 1.873E+01 0.1250 1.117E+02 0.7456 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.791E-01 0.0012 Nb-94 3.518E+00 0.0235 5.890E-02 0.0004 0.000E+00 0.0000 2.705E-01 0.0018 1.116E-05 0.0000 1.641E-04 0.0000 4.181E+00 0.0279 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.675E-03 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.488E-03 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.754E+00 0.0584 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.864E-01 0.0026 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.391E-01 0.0029 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.578E-03 0.0001 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.170E-01 0.0028 Ru-106 1.235E+00 0.0082 3.918E-03 0.0000 0.000E+00 0.0000 9.541E-02 0.0006 2.611E-02 0.0002 9.509E-05 0.0000 1.365E+00 0.0091 Sb-124 3.777E-06 0.0000 2.034E-08 0.0000 0.000E+00 0.0000 2.904E-07 0.0000 3.977E-08 0.0000 8.803E-09 0.0000 4.522E-06 0.0000 Sb-125 7.596E-01 0.0051 6.852E-03 0.0000 0.000E+00 0.0000 6.014E-02 0.0004 1.734E-02 0.0001 3.463E-03 0.0000 8.845E-01 0.0059 Sn-113 8.519E-04 0.0000 1.427E-04 0.0000 0.000E+00 0.0000 6.536E-05 0.0000 8.985E-05 0.0000 1.986E-05 0.0000 1.202E-03 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.556E+00 0.0304 Tc-99 7.195E-01 0.0048 7.924E-04 0.0000 0.000E+00 0.0000 1.222E-01 0.0008 8.373E-04 0.0000 1.769E-02 0.0001 9.023E-01 0.0060 Zn-65 1.947E-01 0.0013 2.745E-02 0.0002 0.000E+00 0.0000 1.638E-02 0.0001 2.073E-01 0.0014 4.561E-02 0.0003 4.991E-01 0.0033 Zr-95 1.909E-07 0.0000 3.039E-09 0.0000 0.000E+00 0.0000 1.347E-08 0.0000 3.925E-13 0.0000 7.744E-12 0.0000 1.272E-05 0.0000 Total 8.741E+01 0.5834 8.789E-01 0.0059 0.000E+00 0.0000 6.861E+00 0.0458 6.171E+00 0.0412 1.892E+01 0.1263 1.498E+02 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 34 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 5.588E-08 0.0000 2.968E-14 0.0000 0.000E+00 0.0000 8.380E-10 0.0000 7.250E-11 0.0000 6.910E-10 0.0000 1.708E-12 0.0000 Am-241 2.287E-02 0.0003 2.553E-02 0.0004 0.000E+00 0.0000 2.850E-01 0.0040 2.930E-03 0.0000 1.671E-04 0.0000 8.953E-02 0.0013 C-14 1.941E-24 0.0000 1.373E-22 0.0000 0.000E+00 0.0000 8.198E-19 0.0000 3.398E-19 0.0000 1.164E-19 0.0000 1.403E-23 0.0000 Ce-144 1.647E-05 0.0000 2.146E-09 0.0000 0.000E+00 0.0000 3.297E-07 0.0000 7.592E-10 0.0000 2.658E-09 0.0000 5.184E-08 0.0000 Cm-242 4.216E-07 0.0000 1.178E-04 0.0000 4.696E-13 0.0000 1.309E-03 0.0000 2.690E-05 0.0000 3.844E-07 0.0000 4.113E-04 0.0000 Cm-243 2.576E-01 0.0036 1.521E-02 0.0002 0.000E+00 0.0000 1.692E-01 0.0024 6.969E-04 0.0000 9.922E-05 0.0000 5.318E-02 0.0007 Co-57 1.628E-05 0.0000 3.288E-11 0.0000 0.000E+00 0.0000 4.653E-07 0.0000 2.502E-07 0.0000 3.014E-08 0.0000 1.830E-09 0.0000 Co-58 2.682E-16 0.0000 5.588E-23 0.0000 0.000E+00 0.0000 1.999E-18 0.0000 1.074E-18 0.0000 1.293E-19 0.0000 7.851E-21 0.0000 Co-60 2.300E+00 0.0323 3.519E-06 0.0000 0.000E+00 0.0000 4.701E-02 0.0007 2.528E-02 0.0004 3.045E-03 0.0000 1.849E-04 0.0000 Cs-134 1.566E-01 0.0022 8.705E-08 0.0000 0.000E+00 0.0000 7.511E-03 0.0001 6.568E-03 0.0001 2.145E-03 0.0000 5.908E-05 0.0000 Cs-137 1.503E+00 0.0211 1.601E-06 0.0000 0.000E+00 0.0000 1.365E-01 0.0019 1.193E-01 0.0017 3.897E-02 0.0005 1.073E-03 0.0000 Eu-154 1.893E+00 0.0266 7.989E-06 0.0000 0.000E+00 0.0000 9.071E-04 0.0000 1.760E-04 0.0000 6.115E-06 0.0000 1.141E-04 0.0000 Fe-55 0.000E+00 0.0000 1.163E-08 0.0000 0.000E+00 0.0000 3.572E-06 0.0000 1.468E-05 0.0000 3.143E-07 0.0000 1.123E-06 0.0000 H-3 0.000E+00 0.0000 1.445E-11 0.0000 0.000E+00 0.0000 5.685E-10 0.0000 1.014E-10 0.0000 8.268E-11 0.0000 4.548E-14 0.0000 I-129 2.410E-05 0.0000 3.478E-08 0.0000 0.000E+00 0.0000 1.531E-03 0.0000 3.838E-04 0.0000 6.673E-04 0.0000 2.360E-05 0.0000 Mn-54 5.979E-04 0.0000 8.826E-11 0.0000 0.000E+00 0.0000 1.488E-05 0.0000 1.877E-07 0.0000 1.338E-07 0.0000 1.561E-08 0.0000 Nb-94 1.176E-03 0.0000 5.725E-09 0.0000 0.000E+00 0.0000 1.382E-06 0.0000 1.907E-11 0.0000 1.576E-10 0.0000 4.223E-08 0.0000 Ni-59 0.000E+00 0.0000 1.725E-07 0.0000 0.000E+00 0.0000 9.118E-04 0.0000 1.288E-04 0.0000 6.268E-04 0.0000 5.738E-06 0.0000 Ni-63 0.000E+00 0.0000 3.725E-07 0.0000 0.000E+00 0.0000 2.323E-03 0.0000 3.280E-04 0.0000 1.597E-03 0.0000 1.462E-05 0.0000 Np-237 6.198E-01 0.0087 3.431E-02 0.0005 0.000E+00 0.0000 7.678E+00 0.1080 2.586E-01 0.0036 1.624E-03 0.0000 1.208E-01 0.0017 Pu-238 8.258E-05 0.0000 2.307E-02 0.0003 1.102E-10 0.0000 2.563E-01 0.0036 5.268E-03 0.0001 7.530E-05 0.0000 8.055E-02 0.0011 Pu-239 1.687E-04 0.0000 2.742E-02 0.0004 0.000E+00 0.0000 3.080E-01 0.0043 6.330E-03 0.0001 9.031E-05 0.0000 9.679E-02 0.0014 Pu-241 3.240E-04 0.0000 6.726E-04 0.0000 0.000E+00 0.0000 7.547E-03 0.0001 1.146E-04 0.0000 3.372E-06 0.0000 2.371E-03 0.0000 Pu-242 7.538E-05 0.0000 2.628E-02 0.0004 4.572E-20 0.0000 2.924E-01 0.0041 6.010E-03 0.0001 8.574E-05 0.0000 9.189E-02 0.0013 Ru-106 1.226E-07 0.0000 5.151E-12 0.0000 0.000E+00 0.0000 1.242E-08 0.0000 8.384E-10 0.0000 1.634E-12 0.0000 1.266E-10 0.0000 Sb-124 2.237E-22 0.0000 5.477E-29 0.0000 0.000E+00 0.0000 3.080E-25 0.0000 1.414E-26 0.0000 1.753E-27 0.0000 9.390E-27 0.0000 Sb-125 2.195E-05 0.0000 1.423E-11 0.0000 0.000E+00 0.0000 6.983E-07 0.0000 7.461E-08 0.0000 7.540E-09 0.0000 1.612E-09 0.0000 Sn-113 2.317E-14 0.0000 1.917E-20 0.0000 0.000E+00 0.0000 1.991E-17 0.0000 2.013E-17 0.0000 2.672E-18 0.0000 2.432E-18 0.0000 Sr-90 1.017E-02 0.0001 6.140E-05 0.0000 0.000E+00 0.0000 2.925E+00 0.0411 5.907E-01 0.0083 1.754E-01 0.0025 3.067E-03 0.0000 Tc-99 1.558E-08 0.0000 1.151E-10 0.0000 0.000E+00 0.0000 1.413E-04 0.0000 3.907E-07 0.0000 4.426E-06 0.0000 8.639E-09 0.0000 Zn-65 9.317E-09 0.0000 5.825E-15 0.0000 0.000E+00 0.0000 2.302E-09 0.0000 6.461E-09 0.0000 7.345E-10 0.0000 1.759E-12 0.0000 Zr-95 1.168E-17 0.0000 3.512E-24 0.0000 0.000E+00 0.0000 6.363E-21 0.0000 1.941E-25 0.0000 6.960E-25 0.0000 3.698E-22 0.0000 Total 6.765E+00 0.0951 1.527E-01 0.0021 1.106E-10 0.0000 1.212E+01 0.1704 1.023E+00 0.0144 2.246E-01 0.0032 5.401E-01 0.0076

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 35 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 3.996E-06 0.0000 2.859E-08 0.0000 0.000E+00 0.0000 3.257E-07 0.0000 1.445E-07 0.0000 2.444E-06 0.0000 6.996E-06 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.260E-01 0.0060 C-14 2.677E-09 0.0000 7.830E-09 0.0000 0.000E+00 0.0000 1.192E-09 0.0000 3.462E-10 0.0000 4.083E-10 0.0000 1.245E-08 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.686E-05 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.865E-03 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.960E-01 0.0070 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.703E-05 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.714E-16 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.375E+00 0.0334 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.729E-01 0.0024 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.799E+00 0.0253 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.895E+00 0.0266 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.971E-05 0.0000 H-3 6.726E-06 0.0000 4.268E-10 0.0000 0.000E+00 0.0000 6.577E-07 0.0000 1.855E-07 0.0000 4.655E-07 0.0000 8.036E-06 0.0000 I-129 3.575E+01 0.5027 7.799E-02 0.0011 0.000E+00 0.0000 2.805E+00 0.0394 2.901E+00 0.0408 8.617E+00 0.1212 5.015E+01 0.7053 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.132E-04 0.0000 Nb-94 9.882E-02 0.0014 1.679E-03 0.0000 0.000E+00 0.0000 7.789E-03 0.0001 3.565E-07 0.0000 4.828E-06 0.0000 1.095E-01 0.0015 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.673E-03 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.262E-03 0.0001 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.713E+00 0.1225 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.654E-01 0.0051 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.388E-01 0.0062 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.103E-02 0.0002 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.167E-01 0.0059 Ru-106 2.962E-04 0.0000 9.536E-07 0.0000 0.000E+00 0.0000 2.346E-05 0.0000 7.125E-06 0.0000 2.388E-08 0.0000 3.279E-04 0.0000 Sb-124 2.200E-20 0.0000 1.204E-22 0.0000 0.000E+00 0.0000 1.736E-21 0.0000 2.642E-22 0.0000 5.375E-23 0.0000 2.439E-20 0.0000 Sb-125 3.771E-03 0.0001 3.452E-05 0.0000 0.000E+00 0.0000 3.061E-04 0.0000 9.793E-05 0.0000 1.800E-05 0.0000 4.250E-03 0.0001 Sn-113 5.692E-12 0.0000 9.681E-13 0.0000 0.000E+00 0.0000 4.480E-13 0.0000 6.841E-13 0.0000 1.390E-13 0.0000 7.955E-12 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.704E+00 0.0521 Tc-99 2.021E-02 0.0003 2.259E-05 0.0000 0.000E+00 0.0000 3.531E-03 0.0000 2.683E-05 0.0000 5.223E-04 0.0000 2.446E-02 0.0003 Zn-65 4.116E-06 0.0000 5.891E-07 0.0000 0.000E+00 0.0000 3.553E-07 0.0000 4.989E-06 0.0000 1.010E-06 0.0000 1.108E-05 0.0000 Zr-95 1.770E-19 0.0000 2.820E-21 0.0000 0.000E+00 0.0000 1.249E-20 0.0000 3.642E-25 0.0000 7.185E-24 0.0000 1.188E-17 0.0000 Total 3.587E+01 0.5045 7.973E-02 0.0011 0.000E+00 0.0000 2.816E+00 0.0396 2.901E+00 0.0408 8.618E+00 0.1212 7.111E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 36 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 8.790E-24 0.0000 4.668E-30 0.0000 0.000E+00 0.0000 1.318E-25 0.0000 1.140E-26 0.0000 1.087E-25 0.0000 2.686E-28 0.0000 Am-241 1.866E-02 0.0013 2.082E-02 0.0015 0.000E+00 0.0000 2.325E-01 0.0164 2.391E-03 0.0002 1.363E-04 0.0000 7.302E-02 0.0052 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 3.023E-13 0.0000 3.939E-17 0.0000 0.000E+00 0.0000 6.050E-15 0.0000 1.393E-17 0.0000 4.877E-17 0.0000 9.512E-16 0.0000 Cm-242 3.594E-07 0.0000 1.004E-04 0.0000 1.200E-11 0.0000 1.116E-03 0.0001 2.293E-05 0.0000 3.289E-07 0.0000 3.506E-04 0.0000 Cm-243 1.580E-01 0.0111 9.338E-03 0.0007 0.000E+00 0.0000 1.039E-01 0.0073 4.303E-04 0.0000 6.089E-05 0.0000 3.266E-02 0.0023 Co-57 1.238E-13 0.0000 2.500E-19 0.0000 0.000E+00 0.0000 3.538E-15 0.0000 1.902E-15 0.0000 2.292E-16 0.0000 1.392E-17 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 1.652E-01 0.0116 2.528E-07 0.0000 0.000E+00 0.0000 3.377E-03 0.0002 1.816E-03 0.0001 2.187E-04 0.0000 1.328E-05 0.0000 Cs-134 1.883E-04 0.0000 1.046E-10 0.0000 0.000E+00 0.0000 9.028E-06 0.0000 7.894E-06 0.0000 2.578E-06 0.0000 7.101E-08 0.0000 Cs-137 9.460E-01 0.0667 1.008E-06 0.0000 0.000E+00 0.0000 8.591E-02 0.0061 7.512E-02 0.0053 2.453E-02 0.0017 6.758E-04 0.0000 Eu-154 3.902E-01 0.0275 1.646E-06 0.0000 0.000E+00 0.0000 1.869E-04 0.0000 3.628E-05 0.0000 1.260E-06 0.0000 2.351E-05 0.0000 Fe-55 0.000E+00 0.0000 6.828E-11 0.0000 0.000E+00 0.0000 2.097E-08 0.0000 8.620E-08 0.0000 1.845E-09 0.0000 6.590E-09 0.0000 H-3 0.000E+00 0.0000 3.218E-26 0.0000 0.000E+00 0.0000 1.267E-24 0.0000 2.265E-25 0.0000 1.846E-25 0.0000 1.013E-28 0.0000 I-129 3.977E-10 0.0000 5.740E-13 0.0000 0.000E+00 0.0000 2.526E-08 0.0000 6.333E-09 0.0000 1.101E-08 0.0000 3.895E-10 0.0000 Mn-54 5.398E-11 0.0000 7.968E-18 0.0000 0.000E+00 0.0000 1.344E-12 0.0000 1.695E-14 0.0000 1.208E-14 0.0000 1.409E-15 0.0000 Nb-94 1.166E-10 0.0000 5.673E-16 0.0000 0.000E+00 0.0000 1.369E-13 0.0000 1.890E-18 0.0000 1.561E-17 0.0000 4.185E-15 0.0000 Ni-59 0.000E+00 0.0000 1.718E-07 0.0000 0.000E+00 0.0000 9.084E-04 0.0001 1.283E-04 0.0000 6.245E-04 0.0000 5.717E-06 0.0000 Ni-63 0.000E+00 0.0000 3.213E-07 0.0000 0.000E+00 0.0000 2.003E-03 0.0001 2.829E-04 0.0000 1.377E-03 0.0001 1.261E-05 0.0000 Np-237 6.115E-01 0.0431 3.386E-02 0.0024 0.000E+00 0.0000 7.575E+00 0.5343 2.551E-01 0.0180 1.603E-03 0.0001 1.192E-01 0.0084 Pu-238 7.040E-05 0.0000 1.966E-02 0.0014 2.509E-09 0.0000 2.185E-01 0.0154 4.490E-03 0.0003 6.443E-05 0.0000 6.866E-02 0.0048 Pu-239 1.683E-04 0.0000 2.736E-02 0.0019 0.000E+00 0.0000 3.073E-01 0.0217 6.315E-03 0.0004 9.010E-05 0.0000 9.657E-02 0.0068 Pu-241 5.426E-04 0.0000 7.241E-04 0.0001 0.000E+00 0.0000 8.098E-03 0.0006 9.740E-05 0.0000 4.347E-06 0.0000 2.544E-03 0.0002 Pu-242 7.524E-05 0.0000 2.623E-02 0.0019 3.116E-18 0.0000 2.919E-01 0.0206 5.999E-03 0.0004 8.559E-05 0.0000 9.173E-02 0.0065 Ru-106 1.296E-20 0.0000 5.444E-25 0.0000 0.000E+00 0.0000 1.313E-21 0.0000 8.859E-23 0.0000 1.727E-25 0.0000 1.338E-23 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 1.460E-14 0.0000 9.461E-21 0.0000 0.000E+00 0.0000 4.644E-16 0.0000 4.961E-17 0.0000 5.014E-18 0.0000 1.072E-18 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 5.634E-03 0.0004 3.400E-05 0.0000 0.000E+00 0.0000 1.620E+00 0.1142 3.271E-01 0.0231 9.711E-02 0.0068 1.699E-03 0.0001 Tc-99 1.544E-15 0.0000 1.141E-17 0.0000 0.000E+00 0.0000 1.401E-11 0.0000 3.873E-14 0.0000 4.388E-13 0.0000 8.566E-16 0.0000 Zn-65 8.903E-25 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.199E-25 0.0000 6.174E-25 0.0000 7.019E-26 0.0000 1.681E-28 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 2.296E+00 0.1620 1.381E-01 0.0097 2.521E-09 0.0000 1.045E+01 0.7371 6.794E-01 0.0479 1.259E-01 0.0089 4.871E-01 0.0344

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 37 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 6.256E-22 0.0000 4.477E-24 0.0000 0.000E+00 0.0000 5.100E-23 0.0000 2.263E-23 0.0000 3.827E-22 0.0000 1.095E-21 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.475E-01 0.0245 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.094E-13 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.590E-03 0.0001 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.044E-01 0.0215 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.295E-13 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.706E-01 0.0120 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.078E-04 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.132E+00 0.0799 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.904E-01 0.0275 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.157E-07 0.0000 H-3 1.649E-20 0.0000 1.046E-24 0.0000 0.000E+00 0.0000 1.613E-21 0.0000 4.552E-22 0.0000 1.141E-21 0.0000 1.970E-20 0.0000 I-129 5.877E-04 0.0000 1.282E-06 0.0000 0.000E+00 0.0000 4.611E-05 0.0000 4.768E-05 0.0000 1.417E-04 0.0000 8.245E-04 0.0001 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.535E-11 0.0000 Nb-94 9.746E-09 0.0000 1.656E-10 0.0000 0.000E+00 0.0000 7.682E-10 0.0000 3.516E-14 0.0000 4.761E-13 0.0000 1.080E-08 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.667E-03 0.0001 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.676E-03 0.0003 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.596E+00 0.6063 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.114E-01 0.0220 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.378E-01 0.0309 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.201E-02 0.0008 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.160E-01 0.0293 Ru-106 3.115E-17 0.0000 1.003E-19 0.0000 0.000E+00 0.0000 2.468E-18 0.0000 7.495E-19 0.0000 2.512E-21 0.0000 3.449E-17 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 2.496E-12 0.0000 2.285E-14 0.0000 0.000E+00 0.0000 2.026E-13 0.0000 6.482E-14 0.0000 1.192E-14 0.0000 2.813E-12 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.051E+00 0.1447 Tc-99 1.995E-09 0.0000 2.230E-12 0.0000 0.000E+00 0.0000 3.485E-10 0.0000 2.648E-12 0.0000 5.155E-11 0.0000 2.414E-09 0.0000 Zn-65 3.914E-22 0.0000 5.602E-23 0.0000 0.000E+00 0.0000 3.379E-23 0.0000 4.744E-22 0.0000 9.605E-23 0.0000 1.054E-21 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 5.877E-04 0.0000 1.282E-06 0.0000 0.000E+00 0.0000 4.611E-05 0.0000 4.768E-05 0.0000 1.417E-04 0.0000 1.418E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 38 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 9.152E-03 0.0005 1.020E-02 0.0006 0.000E+00 0.0000 1.140E-01 0.0068 1.176E-03 0.0001 6.681E-05 0.0000 3.578E-02 0.0021 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 2.057E-07 0.0000 5.741E-05 0.0000 3.504E-10 0.0000 6.378E-04 0.0000 1.311E-05 0.0000 1.911E-07 0.0000 2.004E-04 0.0000 Cm-243 2.854E-02 0.0017 1.713E-03 0.0001 0.000E+00 0.0000 1.907E-02 0.0011 8.379E-05 0.0000 1.109E-05 0.0000 5.992E-03 0.0004 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 1.640E-05 0.0000 2.510E-11 0.0000 0.000E+00 0.0000 3.353E-07 0.0000 1.803E-07 0.0000 2.172E-08 0.0000 1.319E-09 0.0000 Cs-134 1.133E-14 0.0000 6.299E-21 0.0000 0.000E+00 0.0000 5.435E-16 0.0000 4.752E-16 0.0000 1.552E-16 0.0000 4.275E-18 0.0000 Cs-137 1.872E-01 0.0112 1.995E-07 0.0000 0.000E+00 0.0000 1.700E-02 0.0010 1.487E-02 0.0009 4.854E-03 0.0003 1.337E-04 0.0000 Eu-154 1.550E-03 0.0001 6.539E-09 0.0000 0.000E+00 0.0000 7.425E-07 0.0000 1.441E-07 0.0000 5.005E-09 0.0000 9.341E-08 0.0000 Fe-55 0.000E+00 0.0000 1.058E-18 0.0000 0.000E+00 0.0000 3.250E-16 0.0000 1.336E-15 0.0000 2.859E-17 0.0000 1.021E-16 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 7.259E-27 0.0000 1.048E-29 0.0000 0.000E+00 0.0000 4.610E-25 0.0000 1.156E-25 0.0000 2.010E-25 0.0000 7.108E-27 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 1.696E-07 0.0000 0.000E+00 0.0000 8.969E-04 0.0001 1.267E-04 0.0000 6.165E-04 0.0000 5.644E-06 0.0000 Ni-63 0.000E+00 0.0000 1.915E-07 0.0000 0.000E+00 0.0000 1.194E-03 0.0001 1.686E-04 0.0000 8.207E-04 0.0000 7.513E-06 0.0000 Np-237 5.833E-01 0.0348 3.230E-02 0.0019 0.000E+00 0.0000 7.226E+00 0.4313 2.434E-01 0.0145 1.530E-03 0.0001 1.137E-01 0.0068 Pu-238 4.029E-05 0.0000 1.124E-02 0.0007 7.017E-08 0.0000 1.249E-01 0.0075 2.568E-03 0.0002 3.743E-05 0.0000 3.926E-02 0.0023 Pu-239 1.670E-04 0.0000 2.714E-02 0.0016 0.000E+00 0.0000 3.048E-01 0.0182 6.264E-03 0.0004 8.938E-05 0.0000 9.579E-02 0.0057 Pu-241 3.774E-04 0.0000 4.250E-04 0.0000 0.000E+00 0.0000 4.748E-03 0.0003 4.939E-05 0.0000 2.769E-06 0.0000 1.491E-03 0.0001 Pu-242 7.478E-05 0.0000 2.607E-02 0.0016 3.195E-16 0.0000 2.901E-01 0.0173 5.962E-03 0.0004 8.506E-05 0.0000 9.116E-02 0.0054 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 7.120E-04 0.0000 4.297E-06 0.0000 0.000E+00 0.0000 2.047E-01 0.0122 4.134E-02 0.0025 1.227E-02 0.0007 2.147E-04 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 8.112E-01 0.0484 1.091E-01 0.0065 7.052E-08 0.0000 8.308E+00 0.4959 3.160E-01 0.0189 2.039E-02 0.0012 3.837E-01 0.0229

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 39 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 6.118E+00 0.3652 6.368E-02 0.0038 0.000E+00 0.0000 4.702E-01 0.0281 3.267E-03 0.0002 2.864E-04 0.0000 6.826E+00 0.4074 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 3.268E-24 0.0000 5.721E-25 0.0000 0.000E+00 0.0000 2.359E-25 0.0000 1.272E-25 0.0000 2.342E-26 0.0000 9.092E-04 0.0001 Cm-243 2.786E-05 0.0000 2.899E-07 0.0000 0.000E+00 0.0000 2.141E-06 0.0000 1.485E-08 0.0000 1.303E-09 0.0000 5.544E-02 0.0033 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.694E-05 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.251E-14 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.241E-01 0.0134 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.551E-03 0.0001 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.793E-15 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 1.058E-20 0.0000 2.308E-23 0.0000 0.000E+00 0.0000 8.300E-22 0.0000 8.583E-22 0.0000 2.550E-21 0.0000 1.484E-20 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.646E-03 0.0001 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.191E-03 0.0001 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.200E+00 0.4895 Pu-238 8.029E-22 0.0000 1.405E-22 0.0000 0.000E+00 0.0000 5.796E-23 0.0000 3.126E-23 0.0000 5.755E-24 0.0000 1.781E-01 0.0106 Pu-239 4.165E-11 0.0000 3.998E-13 0.0000 0.000E+00 0.0000 3.194E-12 0.0000 8.773E-15 0.0000 1.941E-14 0.0000 4.342E-01 0.0259 Pu-241 1.301E-01 0.0078 1.353E-03 0.0001 0.000E+00 0.0000 9.992E-03 0.0006 6.934E-05 0.0000 6.085E-06 0.0000 1.486E-01 0.0089 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.134E-01 0.0247 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 5.957E-03 0.0004 2.416E-05 0.0000 0.000E+00 0.0000 4.931E-04 0.0000 5.099E-04 0.0000 2.794E-04 0.0000 2.665E-01 0.0159 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 6.254E+00 0.3733 6.506E-02 0.0039 0.000E+00 0.0000 4.807E-01 0.0287 3.846E-03 0.0002 5.719E-04 0.0000 1.675E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 40 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 1.207E-03 0.0001 1.330E-03 0.0001 0.000E+00 0.0000 1.503E-02 0.0007 1.593E-04 0.0000 8.740E-06 0.0000 4.663E-03 0.0002 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 4.237E-08 0.0000 1.163E-05 0.0000 4.901E-09 0.0000 1.292E-04 0.0000 2.655E-06 0.0000 4.205E-08 0.0000 4.058E-05 0.0000 Cm-243 2.155E-04 0.0000 4.400E-05 0.0000 0.000E+00 0.0000 4.928E-04 0.0000 7.807E-06 0.0000 1.860E-07 0.0000 1.549E-04 0.0000 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 5.994E-17 0.0000 9.173E-23 0.0000 0.000E+00 0.0000 1.225E-18 0.0000 6.589E-19 0.0000 7.938E-20 0.0000 4.820E-21 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 1.829E-03 0.0001 1.949E-09 0.0000 0.000E+00 0.0000 1.661E-04 0.0000 1.452E-04 0.0000 4.742E-05 0.0000 1.306E-06 0.0000 Eu-154 2.140E-10 0.0000 9.030E-16 0.0000 0.000E+00 0.0000 1.025E-13 0.0000 1.990E-14 0.0000 6.911E-16 0.0000 1.290E-14 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 1.636E-07 0.0000 0.000E+00 0.0000 8.647E-04 0.0000 1.221E-04 0.0000 5.944E-04 0.0000 5.441E-06 0.0000 Ni-63 0.000E+00 0.0000 4.364E-08 0.0000 0.000E+00 0.0000 2.721E-04 0.0000 3.843E-05 0.0000 1.870E-04 0.0000 1.712E-06 0.0000 Np-237 5.097E-01 0.0244 2.823E-02 0.0014 0.000E+00 0.0000 6.315E+00 0.3021 2.127E-01 0.0102 1.339E-03 0.0001 9.934E-02 0.0048 Pu-238 8.299E-06 0.0000 2.277E-03 0.0001 9.692E-07 0.0000 2.530E-02 0.0012 5.200E-04 0.0000 8.239E-06 0.0000 7.948E-03 0.0004 Pu-239 1.632E-04 0.0000 2.652E-02 0.0013 0.000E+00 0.0000 2.978E-01 0.0142 6.121E-03 0.0003 8.733E-05 0.0000 9.360E-02 0.0045 Pu-241 5.074E-05 0.0000 5.606E-05 0.0000 0.000E+00 0.0000 6.322E-04 0.0000 6.656E-06 0.0000 3.682E-07 0.0000 1.966E-04 0.0000 Pu-242 7.347E-05 0.0000 2.561E-02 0.0012 1.739E-14 0.0000 2.850E-01 0.0136 5.857E-03 0.0003 8.357E-05 0.0000 8.956E-02 0.0043 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 1.931E-06 0.0000 1.166E-08 0.0000 0.000E+00 0.0000 5.554E-04 0.0000 1.122E-04 0.0000 3.330E-05 0.0000 5.824E-07 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 5.133E-01 0.0246 8.407E-02 0.0040 9.741E-07 0.0000 6.941E+00 0.3320 2.258E-01 0.0108 2.390E-03 0.0001 2.955E-01 0.0141

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 41 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 1.143E+01 0.5466 1.190E-01 0.0057 0.000E+00 0.0000 8.787E-01 0.0420 6.117E-03 0.0003 5.355E-04 0.0000 1.245E+01 0.5958 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 2.015E-07 0.0000 2.358E-10 0.0000 3.425E-12 0.0000 1.550E-08 0.0000 7.376E-10 0.0000 2.830E-09 0.0000 1.843E-04 0.0000 Cm-243 1.513E-04 0.0000 1.575E-06 0.0000 0.000E+00 0.0000 1.163E-05 0.0000 8.095E-08 0.0000 7.087E-09 0.0000 1.080E-03 0.0001 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.191E-17 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.189E-03 0.0001 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.141E-10 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.587E-03 0.0001 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.993E-04 0.0000 Np-237 1.095E-04 0.0000 1.160E-07 0.0000 0.000E+00 0.0000 8.422E-06 0.0000 3.980E-07 0.0000 1.539E-06 0.0000 7.166E+00 0.3428 Pu-238 3.992E-05 0.0000 4.676E-08 0.0000 6.851E-10 0.0000 3.070E-06 0.0000 1.461E-07 0.0000 5.608E-07 0.0000 3.610E-02 0.0017 Pu-239 3.953E-08 0.0000 1.877E-10 0.0000 0.000E+00 0.0000 3.039E-09 0.0000 2.822E-10 0.0000 2.717E-10 0.0000 4.243E-01 0.0203 Pu-241 3.774E-01 0.0181 3.930E-03 0.0002 0.000E+00 0.0000 2.902E-02 0.0014 2.020E-04 0.0000 1.768E-05 0.0000 4.115E-01 0.0197 Pu-242 2.974E-09 0.0000 3.222E-12 0.0000 8.408E-15 0.0000 2.287E-10 0.0000 1.083E-11 0.0000 4.178E-11 0.0000 4.062E-01 0.0194 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 3.236E-04 0.0000 1.313E-06 0.0000 0.000E+00 0.0000 2.682E-05 0.0000 2.788E-05 0.0000 1.521E-05 0.0000 1.098E-03 0.0001 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 1.181E+01 0.5647 1.229E-01 0.0059 6.885E-10 0.0000 9.078E-01 0.0434 6.348E-03 0.0003 5.705E-04 0.0000 2.091E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 42 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 1.177E-05 0.0000 1.659E-06 0.0000 0.000E+00 0.0000 1.459E-04 0.0000 4.636E-06 0.0000 3.541E-08 0.0000 5.824E-06 0.0000 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 3.492E-09 0.0000 4.429E-08 0.0000 2.654E-08 0.0000 4.930E-07 0.0000 1.035E-08 0.0000 7.680E-10 0.0000 1.524E-07 0.0000 Cm-243 1.791E-07 0.0000 2.888E-05 0.0000 0.000E+00 0.0000 3.244E-04 0.0001 6.667E-06 0.0000 9.512E-08 0.0000 1.019E-04 0.0000 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 1.685E-10 0.0000 1.796E-16 0.0000 0.000E+00 0.0000 1.530E-11 0.0000 1.338E-11 0.0000 4.370E-12 0.0000 1.204E-13 0.0000 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 1.439E-07 0.0000 0.000E+00 0.0000 7.608E-04 0.0001 1.074E-04 0.0000 5.230E-04 0.0001 4.788E-06 0.0000 Ni-63 0.000E+00 0.0000 2.467E-10 0.0000 0.000E+00 0.0000 1.538E-06 0.0000 2.172E-07 0.0000 1.057E-06 0.0000 9.679E-09 0.0000 Np-237 3.180E-01 0.0595 1.762E-02 0.0033 0.000E+00 0.0000 3.939E+00 0.7368 1.327E-01 0.0248 8.370E-04 0.0002 6.198E-02 0.0116 Pu-238 6.876E-07 0.0000 8.676E-06 0.0000 5.228E-06 0.0000 9.656E-05 0.0000 2.027E-06 0.0000 1.508E-07 0.0000 2.984E-05 0.0000 Pu-239 1.506E-04 0.0000 2.446E-02 0.0046 0.000E+00 0.0000 2.747E-01 0.0514 5.645E-03 0.0011 8.055E-05 0.0000 8.632E-02 0.0161 Pu-241 4.051E-07 0.0000 6.490E-08 0.0000 0.000E+00 0.0000 5.020E-06 0.0000 1.574E-07 0.0000 1.253E-09 0.0000 2.278E-07 0.0000 Pu-242 6.905E-05 0.0000 2.407E-02 0.0045 6.188E-13 0.0000 2.678E-01 0.0501 5.505E-03 0.0010 7.854E-05 0.0000 8.417E-02 0.0157 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 2.008E-15 0.0000 1.212E-17 0.0000 0.000E+00 0.0000 5.775E-13 0.0000 1.166E-13 0.0000 3.462E-14 0.0000 6.055E-16 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 3.183E-01 0.0595 6.618E-02 0.0124 5.254E-06 0.0000 4.483E+00 0.8386 1.439E-01 0.0269 1.520E-03 0.0003 2.326E-01 0.0435

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 43 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 8.687E-02 0.0163 9.037E-04 0.0002 0.000E+00 0.0000 6.682E-03 0.0012 4.846E-05 0.0000 4.089E-06 0.0000 9.468E-02 0.0177 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 9.606E-07 0.0000 5.413E-09 0.0000 5.239E-10 0.0000 7.381E-08 0.0000 4.492E-09 0.0000 1.332E-08 0.0000 1.789E-06 0.0000 Cm-243 5.611E-06 0.0000 5.823E-08 0.0000 0.000E+00 0.0000 4.316E-07 0.0000 3.030E-09 0.0000 2.665E-10 0.0000 4.683E-04 0.0001 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.017E-10 0.0000 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.396E-03 0.0003 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.822E-06 0.0000 Np-237 1.532E-03 0.0003 1.627E-06 0.0000 0.000E+00 0.0000 1.179E-04 0.0000 5.576E-06 0.0000 2.153E-05 0.0000 4.472E+00 0.8365 Pu-238 1.895E-04 0.0000 1.069E-06 0.0000 1.035E-07 0.0000 1.456E-05 0.0000 8.864E-07 0.0000 2.626E-06 0.0000 3.519E-04 0.0001 Pu-239 9.071E-07 0.0000 5.381E-09 0.0000 0.000E+00 0.0000 6.978E-08 0.0000 8.962E-09 0.0000 3.769E-09 0.0000 3.913E-01 0.0732 Pu-241 3.662E-03 0.0007 3.810E-05 0.0000 0.000E+00 0.0000 2.816E-04 0.0001 2.023E-06 0.0000 1.722E-07 0.0000 3.989E-03 0.0007 Pu-242 3.997E-08 0.0000 4.276E-11 0.0000 5.520E-14 0.0000 3.074E-09 0.0000 1.456E-10 0.0000 5.618E-10 0.0000 3.817E-01 0.0714 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 1.095E-11 0.0000 4.444E-14 0.0000 0.000E+00 0.0000 9.077E-13 0.0000 9.445E-13 0.0000 5.150E-13 0.0000 1.409E-11 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 9.227E-02 0.0173 9.445E-04 0.0002 1.041E-07 0.0000 7.097E-03 0.0013 5.697E-05 0.0000 2.844E-05 0.0000 5.346E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 44 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m+D Ag-110m+D 1.000E+00 4.895E+00 1.862E+00 2.903E-01 6.996E-06 1.095E-21 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 4.717E-01 4.669E-01 4.575E-01 4.260E-01 3.474E-01 6.825E+00 1.245E+01 9.433E-02 Am-241 Np-237+D 1.000E+00 1.334E-06 4.133E-06 9.667E-06 2.811E-05 7.364E-05 1.775E-04 3.081E-04 3.558E-04 Am-241 U-233 1.000E+00 3.173E-14 1.795E-13 8.360E-13 6.746E-12 5.053E-11 6.247E-10 1.991E-08 2.448E-07 Am-241 Th-229+D 1.000E+00 9.129E-18 1.299E-16 1.477E-15 3.787E-14 8.607E-13 2.424E-11 3.541E-10 2.830E-09 Am-241 DSR(j) 4.717E-01 4.669E-01 4.575E-01 4.260E-01 3.475E-01 6.826E+00 1.245E+01 9.468E-02 C-14 C-14 1.000E+00 1.324E+00 9.448E-01 9.603E-01 1.245E-08 7.006E-45 0.000E+00 0.000E+00 0.000E+00 Ce-144+D Ce-144+D 1.000E+00 1.245E-01 5.108E-02 8.602E-03 1.686E-05 3.094E-13 2.589E-40 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 4.975E-10 1.050E-10 4.683E-12 8.760E-17 2.716E-30 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 1.346E-11 2.842E-12 1.267E-13 2.370E-18 7.348E-32 0.000E+00 0.000E+00 0.000E+00 Cm-242 Pu-238 1.840E-09 1.823E-12 3.288E-12 3.612E-12 3.432E-12 2.926E-12 1.673E-12 3.386E-13 1.264E-15 Cm-242 DSR(j) 1.528E-11 6.130E-12 3.739E-12 3.432E-12 2.926E-12 1.673E-12 3.386E-13 1.264E-15 Cm-242 Cm-242 1.000E+00 7.316E-03 1.545E-03 6.886E-05 1.288E-09 3.994E-23 0.000E+00 0.000E+00 0.000E+00 Cm-242 Pu-238 1.000E+00 9.907E-04 1.787E-03 1.963E-03 1.865E-03 1.590E-03 9.091E-04 1.840E-04 6.868E-07 Cm-242 U-234 1.000E+00 2.072E-10 1.094E-09 3.407E-09 1.137E-08 3.081E-08 6.961E-08 2.918E-07 1.024E-06 Cm-242 Th-230 1.000E+00 5.959E-16 6.599E-15 4.829E-14 5.234E-13 4.416E-12 3.819E-11 1.779E-10 3.822E-10 Cm-242 Ra-226+D 1.000E+00 3.662E-17 9.262E-16 1.617E-14 5.678E-13 1.452E-11 4.242E-10 5.961E-09 3.592E-08 Cm-242 Pb-210+D 1.000E+00 2.312E-20 1.031E-18 3.514E-17 3.412E-15 2.278E-13 1.594E-11 3.971E-10 1.030E-08 Cm-242 Po-210 1.000E+00 7.003E-22 4.565E-20 2.199E-18 2.903E-16 2.191E-14 1.605E-12 1.989E-10 3.194E-08 Cm-242 DSR(j) 8.306E-03 3.332E-03 2.032E-03 1.865E-03 1.590E-03 9.092E-04 1.843E-04 1.789E-06 Cm-243 Cm-243 2.400E-03 1.520E-03 1.483E-03 1.412E-03 1.190E-03 7.299E-04 1.318E-04 9.923E-07 3.670E-14 Cm-243 Am-243+D 2.400E-03 1.069E-07 3.160E-07 7.138E-07 1.909E-06 4.016E-06 3.486E-05 1.655E-04 6.079E-06 Cm-243 Pu-239 2.400E-03 4.711E-13 3.268E-12 1.691E-11 1.402E-10 9.573E-10 5.493E-09 1.785E-08 3.861E-08 Cm-243 U-235+D 2.400E-03 1.343E-22 2.009E-21 2.309E-20 5.759E-19 1.181E-17 2.486E-16 4.080E-15 5.749E-14 Cm-243 Pa-231 2.400E-03 1.091E-26 3.676E-25 9.573E-24 7.285E-22 4.464E-20 5.467E-18 2.675E-16 1.729E-14 Cm-243 Ac-227+D 2.400E-03 4.414E-29 2.392E-27 1.127E-25 2.190E-23 3.386E-21 8.149E-18 5.895E-16 5.125E-14 Cm-243 DSR(j) 1.520E-03 1.483E-03 1.413E-03 1.192E-03 7.339E-04 1.667E-04 1.666E-04 6.118E-06 Cm-243 Cm-243 9.976E-01 6.317E-01 6.165E-01 5.871E-01 4.947E-01 3.034E-01 5.480E-02 4.125E-04 1.525E-11 Cm-243 Pu-239 9.976E-01 6.253E-06 1.857E-05 4.232E-05 1.168E-04 2.708E-04 4.683E-04 5.008E-04 4.621E-04 Cm-243 U-235+D 9.976E-01 2.383E-15 1.662E-14 8.646E-14 7.265E-13 5.143E-12 3.269E-11 1.139E-10 4.495E-10 Cm-243 Pa-231 9.976E-01 2.497E-19 4.018E-18 4.800E-17 1.232E-15 2.613E-14 5.823E-13 8.359E-12 1.948E-10 Cm-243 Ac-227+D 9.976E-01 1.129E-21 3.027E-20 6.781E-19 4.521E-17 2.390E-15 1.307E-13 1.492E-11 5.887E-10 Cm-243 DSR(j) 6.317E-01 6.165E-01 5.871E-01 4.948E-01 3.037E-01 5.527E-02 9.132E-04 4.621E-04 Co-57 Co-57 1.000E+00 1.953E-01 7.669E-02 1.183E-02 1.703E-05 1.295E-13 4.963E-42 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 9.207E-01 2.577E-02 2.018E-05 2.714E-16 0.000E+00 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 45 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 8.862E+00 7.769E+00 5.970E+00 2.375E+00 1.706E-01 1.694E-05 6.191E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 4.987E+00 3.563E+00 1.819E+00 1.729E-01 2.078E-04 1.251E-14 7.147E-44 0.000E+00 Cs-137+D Cs-137+D 1.000E+00 2.267E+00 2.215E+00 2.115E+00 1.799E+00 1.132E+00 2.241E-01 2.189E-03 2.017E-10 Eu-154 Eu-154 1.000E+00 4.174E+00 3.857E+00 3.293E+00 1.895E+00 3.904E-01 1.551E-03 2.141E-10 2.095E-34 Fe-55 Fe-55 1.000E+00 2.572E-04 1.989E-04 1.190E-04 1.971E-05 1.157E-07 1.793E-15 8.707E-38 0.000E+00 H-3 H-3 1.000E+00 1.671E-02 1.716E-02 1.686E-02 8.036E-06 1.970E-20 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 2.380E+00 4.573E+01 1.117E+02 5.015E+01 8.245E-04 1.484E-20 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 2.041E+00 9.069E-01 1.791E-01 6.132E-04 5.535E-11 1.224E-35 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 4.074E+00 3.918E+00 4.181E+00 1.095E-01 1.080E-08 3.251E-33 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.676E-03 1.676E-03 1.675E-03 1.673E-03 1.667E-03 1.646E-03 1.587E-03 1.396E-03 Ni-63 Ni-63 1.000E+00 4.589E-03 4.555E-03 4.488E-03 4.262E-03 3.676E-03 2.191E-03 4.993E-04 2.822E-06 Np-237+D Np-237+D 1.000E+00 8.772E+00 8.766E+00 8.754E+00 8.713E+00 8.596E+00 8.200E+00 7.166E+00 4.470E+00 Np-237+D U-233 1.000E+00 2.573E-07 6.493E-07 1.406E-06 4.005E-06 1.103E-05 3.138E-05 1.836E-04 1.744E-03 Np-237+D Th-229+D 1.000E+00 1.098E-10 7.423E-10 3.868E-09 3.408E-08 2.790E-07 2.749E-06 1.892E-05 9.689E-05 Np-237+D DSR(j) 8.772E+00 8.766E+00 8.754E+00 8.713E+00 8.596E+00 8.200E+00 7.166E+00 4.472E+00 Pu-238 Pu-238 1.840E-09 7.282E-10 7.224E-10 7.109E-10 6.723E-10 5.730E-10 3.276E-10 6.632E-11 2.475E-13 Pu-238 Pu-238 1.000E+00 3.957E-01 3.926E-01 3.864E-01 3.654E-01 3.114E-01 1.781E-01 3.604E-02 1.345E-04 Pu-238 U-234 1.000E+00 1.164E-07 3.541E-07 8.227E-07 2.380E-06 6.176E-06 1.375E-05 5.770E-05 2.019E-04 Pu-238 Th-230 1.000E+00 3.938E-13 2.627E-12 1.349E-11 1.161E-10 9.046E-10 7.597E-09 3.510E-08 7.525E-08 Pu-238 Ra-226+D 1.000E+00 2.942E-14 4.424E-13 5.141E-12 1.332E-10 3.035E-09 8.494E-08 1.179E-06 7.077E-06 Pu-238 Pb-210+D 1.000E+00 2.081E-17 5.513E-16 1.230E-14 8.390E-13 4.844E-11 3.204E-09 7.866E-08 2.034E-06 Pu-238 Po-210 1.000E+00 6.800E-19 2.597E-17 7.994E-16 7.201E-14 4.664E-12 3.226E-10 3.969E-08 6.312E-06 Pu-238 DSR(j) 3.957E-01 3.926E-01 3.864E-01 3.654E-01 3.114E-01 1.781E-01 3.610E-02 3.519E-04 Pu-239 Pu-239 1.000E+00 4.393E-01 4.392E-01 4.391E-01 4.388E-01 4.378E-01 4.342E-01 4.243E-01 3.913E-01 Pu-239 U-235+D 1.000E+00 2.510E-10 7.541E-10 1.755E-09 5.204E-09 1.459E-08 4.262E-08 1.130E-07 4.037E-07 Pu-239 Pa-231 1.000E+00 3.619E-14 2.691E-13 1.456E-12 1.300E-11 1.051E-10 9.727E-10 1.003E-08 1.839E-07 Pu-239 Ac-227+D 1.000E+00 1.885E-16 2.473E-15 2.612E-14 6.096E-13 1.181E-11 2.685E-10 2.008E-08 5.593E-07 Pu-239 DSR(j) 4.393E-01 4.392E-01 4.391E-01 4.388E-01 4.378E-01 4.342E-01 4.243E-01 3.913E-01

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 46 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Pu-241 Pu-241 1.000E+00 8.284E-03 7.894E-03 7.169E-03 5.115E-03 1.950E-03 6.668E-05 4.320E-09 9.456E-24 Pu-241 Am-241 1.000E+00 3.731E-04 1.090E-03 2.403E-03 5.913E-03 1.006E-02 1.485E-01 4.115E-01 3.978E-03 Pu-241 Np-237+D 1.000E+00 6.784E-10 4.936E-09 2.575E-08 2.044E-07 1.216E-06 5.001E-06 9.926E-06 1.163E-05 Pu-241 U-233 1.000E+00 1.384E-17 1.637E-16 1.596E-15 3.451E-14 6.125E-13 1.234E-11 5.431E-10 7.641E-09 Pu-241 Th-229+D 1.000E+00 2.991E-21 8.583E-20 2.057E-18 1.460E-16 8.203E-15 4.894E-13 1.013E-11 9.154E-11 Pu-241 DSR(j) 8.658E-03 8.985E-03 9.572E-03 1.103E-02 1.201E-02 1.486E-01 4.115E-01 3.989E-03 Pu-241+D Pu-241+D 2.450E-05 7.474E-06 7.122E-06 6.468E-06 4.615E-06 1.759E-06 6.016E-08 3.898E-12 8.531E-27 Pu-241+D Np-237+D 2.450E-05 3.230E-11 9.839E-11 2.219E-10 5.700E-10 1.098E-09 1.357E-09 1.196E-09 7.460E-10 Pu-241+D U-233 2.450E-05 7.692E-19 4.304E-18 1.956E-17 1.452E-16 8.822E-16 4.242E-15 2.523E-14 2.749E-13 Pu-241+D Th-229+D 2.450E-05 2.219E-22 3.131E-21 3.498E-20 8.429E-19 1.632E-17 3.094E-16 2.777E-15 1.560E-14 Pu-241+D DSR(j) 7.474E-06 7.122E-06 6.468E-06 4.615E-06 1.760E-06 6.152E-08 1.200E-09 7.463E-10 Pu-242 Pu-242 5.500E-06 2.294E-06 2.294E-06 2.294E-06 2.292E-06 2.288E-06 2.274E-06 2.234E-06 2.100E-06 Pu-242 Pu-242 5.400E-05 2.252E-05 2.252E-05 2.252E-05 2.250E-05 2.246E-05 2.233E-05 2.193E-05 2.061E-05 Pu-242 U-238 5.400E-05 3.098E-16 9.460E-16 2.215E-15 6.586E-15 1.849E-14 5.408E-14 2.846E-13 2.407E-12 Pu-242 DSR(j) 2.252E-05 2.252E-05 2.252E-05 2.250E-05 2.246E-05 2.233E-05 2.193E-05 2.061E-05 Pu-242 Pu-242 9.999E-01 4.171E-01 4.171E-01 4.170E-01 4.167E-01 4.160E-01 4.134E-01 4.061E-01 3.817E-01 Pu-242 U-238+D 9.999E-01 1.266E-11 3.828E-11 8.930E-11 2.651E-10 7.438E-10 2.175E-09 7.992E-09 5.044E-08 Pu-242 U-234 9.999E-01 6.211E-18 4.345E-17 2.287E-16 2.013E-15 1.620E-14 1.498E-13 3.296E-12 9.518E-11 Pu-242 Th-230 9.999E-01 1.577E-23 2.229E-22 2.514E-21 6.472E-20 1.520E-18 4.810E-17 9.501E-16 1.335E-14 Pu-242 Ra-226+D 9.999E-01 9.118E-25 2.840E-23 7.153E-22 5.527E-20 3.769E-18 3.867E-16 7.702E-14 1.121E-12 Pu-242 Pb-210+D 9.999E-01 5.617E-28 3.011E-26 1.415E-24 2.836E-22 4.928E-20 1.236E-17 1.306E-13 8.829E-13 Pu-242 Po-210 9.999E-01 1.676E-29 1.299E-27 8.528E-26 2.339E-23 4.668E-21 1.237E-18 5.211E-13 3.313E-12 Pu-242 DSR(j) 4.171E-01 4.171E-01 4.170E-01 4.167E-01 4.160E-01 4.134E-01 4.061E-01 3.817E-01 Ru-106+D Ru-106+D 1.000E+00 1.136E+00 3.118E+00 1.365E+00 3.279E-04 3.449E-17 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 1.323E+00 1.752E-02 4.522E-06 2.439E-20 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 7.390E-01 6.921E-01 5.157E-01 2.448E-03 1.620E-12 1.121E-44 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 2.183E-01 2.044E-01 1.523E-01 7.229E-04 4.785E-13 0.000E+00 0.000E+00 0.000E+00 Sb-125 Te-125m 2.280E-01 5.380E-02 2.131E-01 2.165E-01 1.080E-03 7.146E-13 0.000E+00 0.000E+00 0.000E+00 Sb-125 DSR(j) 2.721E-01 4.175E-01 3.688E-01 1.803E-03 1.193E-12 0.000E+00 0.000E+00 0.000E+00 Sn-113+D Sn-113+D 1.000E+00 2.920E-01 6.184E-02 1.202E-03 7.955E-12 6.161E-38 0.000E+00 0.000E+00 0.000E+00 Sr-90+D Sr-90+D 1.000E+00 4.978E+00 4.833E+00 4.556E+00 3.704E+00 2.051E+00 2.665E-01 1.098E-03 1.409E-11 Tc-99 Tc-99 1.000E+00 5.346E-01 7.089E-01 9.023E-01 2.446E-02 2.414E-09 7.284E-34 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 2.399E+00 2.359E+00 4.991E-01 1.108E-05 1.054E-21 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 47 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95+D Zr-95+D 1.000E+00 6.298E-01 1.204E-02 4.401E-06 4.108E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Zr-95+D Nb-95 1.000E+00 5.768E-01 2.240E-02 8.322E-06 7.767E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Zr-95+D DSR(j) 1.207E+00 3.444E-02 1.272E-05 1.188E-17 0.000E+00 0.000E+00 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life ó 30 days) daughters.

Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m 5.108E+00 1.342E+01 8.612E+01 3.573E+06 *4.754E+15 *4.754E+15 *4.754E+15 *4.754E+15 Am-241 5.300E+01 5.354E+01 5.464E+01 5.868E+01 7.194E+01 3.663E+00 2.007E+00 2.640E+02 C-14 1.889E+01 2.646E+01 2.603E+01 2.007E+09 *4.455E+12 *4.455E+12 *4.455E+12 *4.455E+12 Ce-144 2.009E+02 4.894E+02 2.906E+03 1.483E+06 8.081E+13 *3.191E+15 *3.191E+15 *3.191E+15 Cm-242 3.010E+03 7.504E+03 1.230E+04 1.340E+04 1.572E+04 2.750E+04 1.356E+05 1.397E+07 Cm-243 3.948E+01 4.045E+01 4.248E+01 5.040E+01 8.213E+01 4.509E+02 2.315E+04 5.339E+04 Co-57 1.280E+02 3.260E+02 2.114E+03 1.468E+06 1.931E+14 *8.465E+15 *8.465E+15 *8.465E+15 Co-58 2.715E+01 9.702E+02 1.239E+06 *3.183E+16 *3.183E+16 *3.183E+16 *3.183E+16 *3.183E+16 Co-60 2.821E+00 3.218E+00 4.187E+00 1.053E+01 1.465E+02 1.476E+06 *1.132E+15 *1.132E+15 Cs-134 5.013E+00 7.016E+00 1.374E+01 1.446E+02 1.203E+05 *1.295E+15 *1.295E+15 *1.295E+15 Cs-137 1.103E+01 1.129E+01 1.182E+01 1.390E+01 2.208E+01 1.116E+02 1.142E+04 1.239E+11 Eu-154 5.990E+00 6.482E+00 7.591E+00 1.320E+01 6.403E+01 1.612E+04 1.167E+11 *2.639E+14 Fe-55 9.720E+04 1.257E+05 2.101E+05 1.269E+06 2.161E+08 *2.410E+15 *2.410E+15 *2.410E+15 H-3 1.496E+03 1.457E+03 1.483E+03 3.111E+06 *9.597E+15 *9.597E+15 *9.597E+15 *9.597E+15 I-129 1.050E+01 5.467E-01 2.238E-01 4.985E-01 3.032E+04 *1.766E+08 *1.766E+08 *1.766E+08 Mn-54 1.225E+01 2.757E+01 1.396E+02 4.077E+04 4.516E+11 *7.746E+15 *7.746E+15 *7.746E+15 Nb-94 6.136E+00 6.381E+00 5.980E+00 2.284E+02 2.315E+09 *1.875E+11 *1.875E+11 *1.875E+11 Ni-59 1.491E+04 1.492E+04 1.492E+04 1.494E+04 1.500E+04 1.519E+04 1.575E+04 1.791E+04 Ni-63 5.448E+03 5.488E+03 5.570E+03 5.866E+03 6.801E+03 1.141E+04 5.007E+04 8.858E+06 Np-237 2.850E+00 2.852E+00 2.856E+00 2.869E+00 2.908E+00 3.049E+00 3.489E+00 5.590E+00 Pu-238 6.317E+01 6.368E+01 6.470E+01 6.842E+01 8.027E+01 1.404E+02 6.925E+02 7.105E+04 Pu-239 5.691E+01 5.692E+01 5.693E+01 5.698E+01 5.711E+01 5.757E+01 5.892E+01 6.388E+01 Pu-241 2.885E+03 2.780E+03 2.610E+03 2.266E+03 2.081E+03 1.683E+02 6.075E+01 6.267E+03 Pu-242 5.994E+01 5.994E+01 5.995E+01 5.999E+01 6.010E+01 6.047E+01 6.155E+01 6.549E+01 Ru-106 2.201E+01 8.017E+00 1.831E+01 7.625E+04 *3.348E+15 *3.348E+15 *3.348E+15 *3.348E+15 Sb-124 1.890E+01 1.427E+03 5.528E+06 *1.750E+16 *1.750E+16 *1.750E+16 *1.750E+16 *1.750E+16 Sb-125 2.473E+01 2.253E+01 2.827E+01 5.882E+03 8.886E+12 *1.033E+15 *1.033E+15 *1.033E+15 Sn-113 8.562E+01 4.043E+02 2.081E+04 3.143E+12 *1.005E+16 *1.005E+16 *1.005E+16 *1.005E+16 Sr-90 5.022E+00 5.173E+00 5.488E+00 6.749E+00 1.219E+01 9.380E+01 2.276E+04 1.774E+12 Tc-99 4.676E+01 3.527E+01 2.771E+01 1.022E+03 1.036E+10 *1.697E+10 *1.697E+10 *1.697E+10 Zn-65 1.042E+01 1.060E+01 5.009E+01 2.257E+06 *8.245E+15 *8.245E+15 *8.245E+15 *8.245E+15 Zr-95 2.072E+01 7.259E+02 1.965E+06 *2.150E+16 *2.150E+16 *2.150E+16 *2.150E+16 *2.150E+16

  • At specific activity limit

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 48 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 5.49 n 0.01 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)

(i) (pCi/g) (years) (pCi/g) (pCi/g)

Ag-110m 1.000E+00 0.000E+00 4.895E+00 5.108E+00 2.237E-02 1.118E+03 Am-241 1.000E+00 264.0 n 0.5 1.257E+01 1.989E+00 4.461E-01 5.605E+01 C-14 1.000E+00 0.000E+00 1.324E+00 1.889E+01 6.522E-01 3.833E+01 Ce-144 1.000E+00 0.000E+00 1.245E-01 2.009E+02 9.371E-04 2.668E+04 Cm-242 1.000E+00 0.000E+00 8.306E-03 3.010E+03 1.935E-03 1.292E+04 Cm-243 1.000E+00 0.000E+00 6.333E-01 3.948E+01 5.538E-01 4.514E+01 Co-57 1.000E+00 0.000E+00 1.953E-01 1.280E+02 1.155E-03 2.165E+04 Co-58 1.000E+00 0.000E+00 9.207E-01 2.715E+01 2.750E-09 9.091E+09 Co-60 1.000E+00 0.000E+00 8.862E+00 2.821E+00 4.302E+00 5.812E+00 Cs-134 1.000E+00 0.000E+00 4.987E+00 5.013E+00 7.878E-01 3.173E+01 Cs-137 1.000E+00 0.000E+00 2.267E+00 1.103E+01 1.997E+00 1.252E+01 Eu-154 1.000E+00 0.000E+00 4.174E+00 5.990E+00 2.705E+00 9.240E+00 Fe-55 1.000E+00 0.000E+00 2.572E-04 9.720E+04 6.279E-05 3.982E+05 H-3 1.000E+00 1.635 n 0.003 1.765E-02 1.416E+03 1.202E-02 2.080E+03 I-129 1.000E+00 7.56 n 0.02 1.419E+02 1.762E-01 1.362E+02 1.835E-01 Mn-54 1.000E+00 0.000E+00 2.041E+00 1.225E+01 2.379E-02 1.051E+03 Nb-94 1.000E+00 4.929 n 0.010 4.232E+00 5.908E+00 3.781E+00 6.612E+00 Ni-59 1.000E+00 0.000E+00 1.676E-03 1.491E+04 1.675E-03 1.493E+04 Ni-63 1.000E+00 0.000E+00 4.589E-03 5.448E+03 4.407E-03 5.673E+03 Np-237 1.000E+00 0.000E+00 8.772E+00 2.850E+00 8.740E+00 2.861E+00 Pu-238 1.000E+00 0.000E+00 3.957E-01 6.317E+01 3.788E-01 6.600E+01 Pu-239 1.000E+00 0.000E+00 4.393E-01 5.691E+01 4.390E-01 5.695E+01 Pu-241 1.000E+00 288.3 n 0.6 4.120E-01 6.068E+01 1.019E-02 2.452E+03 Pu-242 1.000E+00 0.000E+00 4.171E-01 5.994E+01 4.169E-01 5.996E+01 Ru-106 1.000E+00 1.046 n 0.002 3.121E+00 8.009E+00 2.460E-01 1.016E+02 Sb-124 1.000E+00 0.000E+00 1.323E+00 1.890E+01 1.301E-10 1.922E+11 Sb-125 1.000E+00 1.219 n 0.002 1.118E+00 2.237E+01 4.495E-01 5.562E+01 Sn-113 1.000E+00 0.000E+00 2.920E-01 8.562E+01 5.189E-06 4.818E+06 Sr-90 1.000E+00 0.000E+00 4.978E+00 5.022E+00 4.233E+00 5.907E+00 Tc-99 1.000E+00 4.929 n 0.010 9.402E-01 2.659E+01 8.431E-01 2.965E+01 Zn-65 1.000E+00 0.000E+00 2.399E+00 1.042E+01 3.850E-02 6.493E+02 Zr-95 1.000E+00 0.000E+00 1.207E+00 2.072E+01 6.714E-10 3.724E+10

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 49 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m Ag-110m 1.000E+00 4.895E+00 1.862E+00 2.903E-01 6.996E-06 1.095E-21 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 4.717E-01 4.669E-01 4.575E-01 4.260E-01 3.474E-01 6.825E+00 1.245E+01 9.433E-02 Am-241 Pu-241 1.000E+00 3.731E-04 1.090E-03 2.403E-03 5.913E-03 1.006E-02 1.485E-01 4.115E-01 3.978E-03 Am-241 DOSE(j) 4.721E-01 4.680E-01 4.599E-01 4.319E-01 3.575E-01 6.974E+00 1.287E+01 9.830E-02 Np-237 Am-241 1.000E+00 1.334E-06 4.133E-06 9.667E-06 2.811E-05 7.364E-05 1.775E-04 3.081E-04 3.558E-04 Np-237 Np-237 1.000E+00 8.772E+00 8.766E+00 8.754E+00 8.713E+00 8.596E+00 8.200E+00 7.166E+00 4.470E+00 Np-237 Pu-241 1.000E+00 6.784E-10 4.936E-09 2.575E-08 2.044E-07 1.216E-06 5.001E-06 9.926E-06 1.163E-05 Np-237 Pu-241 2.450E-05 3.230E-11 9.839E-11 2.219E-10 5.700E-10 1.098E-09 1.357E-09 1.196E-09 7.460E-10 Np-237 DOSE(j) 8.772E+00 8.766E+00 8.754E+00 8.713E+00 8.597E+00 8.200E+00 7.166E+00 4.470E+00 U-233 Am-241 1.000E+00 3.173E-14 1.795E-13 8.360E-13 6.746E-12 5.053E-11 6.247E-10 1.991E-08 2.448E-07 U-233 Np-237 1.000E+00 2.573E-07 6.493E-07 1.406E-06 4.005E-06 1.103E-05 3.138E-05 1.836E-04 1.744E-03 U-233 Pu-241 1.000E+00 1.384E-17 1.637E-16 1.596E-15 3.451E-14 6.125E-13 1.234E-11 5.431E-10 7.641E-09 U-233 Pu-241 2.450E-05 7.692E-19 4.304E-18 1.956E-17 1.452E-16 8.822E-16 4.242E-15 2.523E-14 2.749E-13 U-233 DOSE(j) 2.573E-07 6.493E-07 1.406E-06 4.005E-06 1.103E-05 3.138E-05 1.836E-04 1.744E-03 Th-229 Am-241 1.000E+00 9.129E-18 1.299E-16 1.477E-15 3.787E-14 8.607E-13 2.424E-11 3.541E-10 2.830E-09 Th-229 Np-237 1.000E+00 1.098E-10 7.423E-10 3.868E-09 3.408E-08 2.790E-07 2.749E-06 1.892E-05 9.689E-05 Th-229 Pu-241 1.000E+00 2.991E-21 8.583E-20 2.057E-18 1.460E-16 8.203E-15 4.894E-13 1.013E-11 9.154E-11 Th-229 Pu-241 2.450E-05 2.219E-22 3.131E-21 3.498E-20 8.429E-19 1.632E-17 3.094E-16 2.777E-15 1.560E-14 Th-229 DOSE(j) 1.098E-10 7.423E-10 3.868E-09 3.408E-08 2.790E-07 2.749E-06 1.892E-05 9.689E-05 C-14 C-14 1.000E+00 1.324E+00 9.448E-01 9.603E-01 1.245E-08 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Ce-144 Ce-144 1.000E+00 1.245E-01 5.108E-02 8.602E-03 1.686E-05 3.094E-13 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 4.975E-10 1.050E-10 4.683E-12 8.760E-17 1.886E-30 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 1.346E-11 2.842E-12 1.267E-13 2.370E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Cm-242 DOSE(j) 5.109E-10 1.079E-10 4.809E-12 8.997E-17 1.886E-30 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.840E-09 1.823E-12 3.288E-12 3.612E-12 3.432E-12 2.926E-12 1.673E-12 3.386E-13 1.264E-15 Pu-238 Pu-238 1.840E-09 7.282E-10 7.224E-10 7.109E-10 6.723E-10 5.730E-10 3.276E-10 6.632E-11 2.475E-13 Pu-238 DOSE(j) 7.300E-10 7.257E-10 7.145E-10 6.757E-10 5.759E-10 3.293E-10 6.666E-11 2.488E-13 Cm-242 Cm-242 1.000E+00 7.316E-03 1.545E-03 6.886E-05 1.288E-09 3.994E-23 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.000E+00 9.907E-04 1.787E-03 1.963E-03 1.865E-03 1.590E-03 9.091E-04 1.840E-04 6.868E-07 U-234 Cm-242 1.000E+00 2.072E-10 1.094E-09 3.407E-09 1.137E-08 3.081E-08 6.961E-08 2.918E-07 1.024E-06 U-234 Pu-238 1.000E+00 1.164E-07 3.541E-07 8.227E-07 2.380E-06 6.176E-06 1.375E-05 5.770E-05 2.019E-04 U-234 Pu-242 9.999E-01 6.211E-18 4.345E-17 2.287E-16 2.013E-15 1.620E-14 1.498E-13 3.296E-12 9.518E-11 U-234 DOSE(j) 1.166E-07 3.552E-07 8.261E-07 2.391E-06 6.207E-06 1.381E-05 5.799E-05 2.029E-04 Th-230 Cm-242 1.000E+00 5.959E-16 6.599E-15 4.829E-14 5.234E-13 4.416E-12 3.819E-11 1.779E-10 3.822E-10 Th-230 Pu-238 1.000E+00 3.938E-13 2.627E-12 1.349E-11 1.161E-10 9.046E-10 7.597E-09 3.510E-08 7.525E-08 Th-230 Pu-242 9.999E-01 1.577E-23 2.229E-22 2.514E-21 6.472E-20 1.520E-18 4.810E-17 9.501E-16 1.335E-14 Th-230 DOSE(j) 3.944E-13 2.634E-12 1.354E-11 1.167E-10 9.090E-10 7.636E-09 3.528E-08 7.563E-08

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 50 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ra-226 Cm-242 1.000E+00 3.662E-17 9.262E-16 1.617E-14 5.678E-13 1.452E-11 4.242E-10 5.961E-09 3.592E-08 Ra-226 Pu-238 1.000E+00 2.942E-14 4.424E-13 5.141E-12 1.332E-10 3.035E-09 8.494E-08 1.179E-06 7.077E-06 Ra-226 Pu-242 9.999E-01 9.118E-25 2.840E-23 7.153E-22 5.527E-20 3.769E-18 3.867E-16 7.702E-14 1.121E-12 Ra-226 DOSE(j) 2.946E-14 4.434E-13 5.157E-12 1.338E-10 3.050E-09 8.536E-08 1.185E-06 7.113E-06 Pb-210 Cm-242 1.000E+00 2.312E-20 1.031E-18 3.514E-17 3.412E-15 2.278E-13 1.594E-11 3.971E-10 1.030E-08 Pb-210 Pu-238 1.000E+00 2.081E-17 5.513E-16 1.230E-14 8.390E-13 4.844E-11 3.204E-09 7.866E-08 2.034E-06 Pb-210 Pu-242 9.999E-01 5.614E-28 3.011E-26 1.415E-24 2.836E-22 4.928E-20 1.236E-17 1.306E-13 8.829E-13 Pb-210 DOSE(j) 2.083E-17 5.523E-16 1.233E-14 8.424E-13 4.866E-11 3.220E-09 7.906E-08 2.044E-06 Po-210 Cm-242 1.000E+00 7.003E-22 4.565E-20 2.199E-18 2.903E-16 2.191E-14 1.605E-12 1.989E-10 3.194E-08 Po-210 Pu-238 1.000E+00 6.800E-19 2.597E-17 7.994E-16 7.201E-14 4.664E-12 3.226E-10 3.969E-08 6.312E-06 Po-210 Pu-242 9.999E-01 1.539E-29 1.298E-27 8.528E-26 2.339E-23 4.668E-21 1.237E-18 5.211E-13 3.313E-12 Po-210 DOSE(j) 6.807E-19 2.602E-17 8.016E-16 7.230E-14 4.686E-12 3.242E-10 3.989E-08 6.344E-06 Cm-243 Cm-243 2.400E-03 1.520E-03 1.483E-03 1.412E-03 1.190E-03 7.299E-04 1.318E-04 9.923E-07 3.670E-14 Cm-243 Cm-243 9.976E-01 6.317E-01 6.165E-01 5.871E-01 4.947E-01 3.034E-01 5.480E-02 4.125E-04 1.525E-11 Cm-243 DOSE(j) 6.333E-01 6.180E-01 5.885E-01 4.959E-01 3.041E-01 5.494E-02 4.135E-04 1.529E-11 Am-243 Cm-243 2.400E-03 1.069E-07 3.160E-07 7.138E-07 1.909E-06 4.016E-06 3.486E-05 1.655E-04 6.079E-06 Pu-239 Cm-243 2.400E-03 4.711E-13 3.268E-12 1.691E-11 1.402E-10 9.573E-10 5.493E-09 1.785E-08 3.861E-08 Pu-239 Cm-243 9.976E-01 6.253E-06 1.857E-05 4.232E-05 1.168E-04 2.708E-04 4.683E-04 5.008E-04 4.621E-04 Pu-239 Pu-239 1.000E+00 4.393E-01 4.392E-01 4.391E-01 4.388E-01 4.378E-01 4.342E-01 4.243E-01 3.913E-01 Pu-239 DOSE(j) 4.393E-01 4.393E-01 4.392E-01 4.389E-01 4.380E-01 4.347E-01 4.248E-01 3.918E-01 U-235 Cm-243 2.400E-03 1.343E-22 2.009E-21 2.309E-20 5.759E-19 1.181E-17 2.486E-16 4.080E-15 5.749E-14 U-235 Cm-243 9.976E-01 2.383E-15 1.662E-14 8.646E-14 7.265E-13 5.143E-12 3.269E-11 1.139E-10 4.495E-10 U-235 Pu-239 1.000E+00 2.510E-10 7.541E-10 1.755E-09 5.204E-09 1.459E-08 4.262E-08 1.130E-07 4.037E-07 U-235 DOSE(j) 2.510E-10 7.541E-10 1.755E-09 5.204E-09 1.460E-08 4.265E-08 1.132E-07 4.042E-07 Pa-231 Cm-243 2.400E-03 1.091E-26 3.676E-25 9.573E-24 7.285E-22 4.464E-20 5.467E-18 2.675E-16 1.729E-14 Pa-231 Cm-243 9.976E-01 2.497E-19 4.018E-18 4.800E-17 1.232E-15 2.613E-14 5.823E-13 8.359E-12 1.948E-10 Pa-231 Pu-239 1.000E+00 3.619E-14 2.691E-13 1.456E-12 1.300E-11 1.051E-10 9.727E-10 1.003E-08 1.839E-07 Pa-231 DOSE(j) 3.619E-14 2.691E-13 1.456E-12 1.300E-11 1.052E-10 9.733E-10 1.004E-08 1.841E-07 Ac-227 Cm-243 2.400E-03 4.408E-29 2.392E-27 1.127E-25 2.190E-23 3.386E-21 8.149E-18 5.895E-16 5.125E-14 Ac-227 Cm-243 9.976E-01 1.129E-21 3.027E-20 6.781E-19 4.521E-17 2.390E-15 1.307E-13 1.492E-11 5.887E-10 Ac-227 Pu-239 1.000E+00 1.885E-16 2.473E-15 2.612E-14 6.096E-13 1.181E-11 2.685E-10 2.008E-08 5.593E-07 Ac-227 DOSE(j) 1.885E-16 2.473E-15 2.612E-14 6.097E-13 1.181E-11 2.686E-10 2.009E-08 5.599E-07 Co-57 Co-57 1.000E+00 1.953E-01 7.669E-02 1.183E-02 1.703E-05 1.295E-13 0.000E+00 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 9.207E-01 2.577E-02 2.018E-05 2.714E-16 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Co-60 Co-60 1.000E+00 8.862E+00 7.769E+00 5.970E+00 2.375E+00 1.706E-01 1.694E-05 6.191E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 4.987E+00 3.563E+00 1.819E+00 1.729E-01 2.078E-04 1.251E-14 0.000E+00 0.000E+00 Cs-137 Cs-137 1.000E+00 2.267E+00 2.215E+00 2.115E+00 1.799E+00 1.132E+00 2.241E-01 2.189E-03 2.017E-10

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 51 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Eu-154 Eu-154 1.000E+00 4.174E+00 3.857E+00 3.293E+00 1.895E+00 3.904E-01 1.551E-03 2.141E-10 0.000E+00 Fe-55 Fe-55 1.000E+00 2.572E-04 1.989E-04 1.190E-04 1.971E-05 1.157E-07 1.793E-15 0.000E+00 0.000E+00 H-3 H-3 1.000E+00 1.671E-02 1.716E-02 1.686E-02 8.036E-06 1.970E-20 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 2.380E+00 4.573E+01 1.117E+02 5.015E+01 8.245E-04 1.484E-20 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 2.041E+00 9.069E-01 1.791E-01 6.132E-04 5.535E-11 0.000E+00 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 4.074E+00 3.918E+00 4.181E+00 1.095E-01 1.080E-08 0.000E+00 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.676E-03 1.676E-03 1.675E-03 1.673E-03 1.667E-03 1.646E-03 1.587E-03 1.396E-03 Ni-63 Ni-63 1.000E+00 4.589E-03 4.555E-03 4.488E-03 4.262E-03 3.676E-03 2.191E-03 4.993E-04 2.822E-06 Pu-238 Pu-238 1.000E+00 3.957E-01 3.926E-01 3.864E-01 3.654E-01 3.114E-01 1.781E-01 3.604E-02 1.345E-04 Pu-241 Pu-241 1.000E+00 8.284E-03 7.894E-03 7.169E-03 5.115E-03 1.950E-03 6.668E-05 4.320E-09 9.456E-24 Pu-241 Pu-241 2.450E-05 7.474E-06 7.122E-06 6.468E-06 4.615E-06 1.759E-06 6.016E-08 3.898E-12 8.531E-27 Pu-241 DOSE(j) 8.292E-03 7.902E-03 7.175E-03 5.120E-03 1.952E-03 6.674E-05 4.324E-09 9.465E-24 Pu-242 Pu-242 5.500E-06 2.294E-06 2.294E-06 2.294E-06 2.292E-06 2.288E-06 2.274E-06 2.234E-06 2.100E-06 Pu-242 Pu-242 5.400E-05 2.252E-05 2.252E-05 2.252E-05 2.250E-05 2.246E-05 2.233E-05 2.193E-05 2.061E-05 Pu-242 DOSE(j) 2.482E-05 2.482E-05 2.481E-05 2.480E-05 2.475E-05 2.460E-05 2.417E-05 2.271E-05 U-238 Pu-242 5.400E-05 3.098E-16 9.460E-16 2.215E-15 6.586E-15 1.849E-14 5.408E-14 2.846E-13 2.407E-12 U-238 Pu-242 9.999E-01 1.266E-11 3.828E-11 8.930E-11 2.651E-10 7.438E-10 2.175E-09 7.992E-09 5.044E-08 U-238 DOSE(j) 1.266E-11 3.828E-11 8.930E-11 2.651E-10 7.438E-10 2.175E-09 7.992E-09 5.044E-08 Pu-242 Pu-242 9.999E-01 4.171E-01 4.171E-01 4.170E-01 4.167E-01 4.160E-01 4.134E-01 4.061E-01 3.817E-01 Ru-106 Ru-106 1.000E+00 1.136E+00 3.118E+00 1.365E+00 3.279E-04 3.449E-17 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 1.323E+00 1.752E-02 4.522E-06 2.439E-20 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 7.390E-01 6.921E-01 5.157E-01 2.448E-03 1.620E-12 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 2.183E-01 2.044E-01 1.523E-01 7.229E-04 4.785E-13 0.000E+00 0.000E+00 0.000E+00 Sb-125 DOSE(j) 9.573E-01 8.966E-01 6.680E-01 3.171E-03 2.099E-12 0.000E+00 0.000E+00 0.000E+00 Te-125m Sb-125 2.280E-01 5.380E-02 2.131E-01 2.165E-01 1.080E-03 7.146E-13 0.000E+00 0.000E+00 0.000E+00 Sn-113 Sn-113 1.000E+00 2.920E-01 6.184E-02 1.202E-03 7.955E-12 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sr-90 Sr-90 1.000E+00 4.978E+00 4.833E+00 4.556E+00 3.704E+00 2.051E+00 2.665E-01 1.098E-03 1.409E-11 Tc-99 Tc-99 1.000E+00 5.346E-01 7.089E-01 9.023E-01 2.446E-02 2.414E-09 0.000E+00 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 2.399E+00 2.359E+00 4.991E-01 1.108E-05 1.054E-21 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 52 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95 Zr-95 1.000E+00 6.298E-01 1.204E-02 4.401E-06 4.108E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Nb-95 Zr-95 1.000E+00 5.768E-01 2.240E-02 8.322E-06 7.767E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 53 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m Ag-110m 1.000E+00 1.000E+00 1.621E-01 4.261E-03 1.254E-08 1.973E-24 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 1.000E+00 9.899E-01 9.699E-01 9.031E-01 7.366E-01 3.609E-01 4.700E-02 3.747E-05 Am-241 Pu-241 1.000E+00 0.000E+00 1.558E-03 4.410E-03 1.205E-02 2.114E-02 1.488E-02 1.982E-03 1.580E-06 Am-241 S(j): 1.000E+00 9.914E-01 9.743E-01 9.152E-01 7.577E-01 3.758E-01 4.898E-02 3.905E-05 Np-237 Am-241 1.000E+00 0.000E+00 3.221E-07 9.560E-07 3.069E-06 8.284E-06 1.953E-05 2.620E-05 1.734E-05 Np-237 Np-237 1.000E+00 1.000E+00 9.993E-01 9.980E-01 9.933E-01 9.800E-01 9.348E-01 8.169E-01 5.096E-01 Np-237 Pu-241 1.000E+00 0.000E+00 2.547E-10 2.204E-09 2.144E-08 1.354E-07 5.574E-07 8.702E-07 5.849E-07 Np-237 Pu-241 2.450E-05 0.000E+00 7.745E-12 2.214E-11 6.273E-11 1.243E-10 1.547E-10 1.363E-10 8.505E-11 Np-237 S(j): 1.000E+00 9.993E-01 9.980E-01 9.933E-01 9.800E-01 9.348E-01 8.169E-01 5.096E-01 U-233 Am-241 1.000E+00 0.000E+00 7.049E-13 6.284E-12 6.753E-11 5.533E-10 4.479E-09 1.793E-08 2.484E-08 U-233 Np-237 1.000E+00 0.000E+00 4.364E-06 1.304E-05 4.284E-05 1.233E-04 3.568E-04 7.262E-04 7.502E-04 U-233 Pu-241 1.000E+00 0.000E+00 3.727E-16 9.757E-15 3.250E-13 6.594E-12 1.060E-10 5.573E-10 8.328E-10 U-233 Pu-241 2.450E-05 0.000E+00 1.705E-17 1.483E-16 1.466E-15 9.725E-15 4.814E-14 1.154E-13 1.247E-13 U-233 S(j): 0.000E+00 4.364E-06 1.304E-05 4.284E-05 1.233E-04 3.568E-04 7.262E-04 7.502E-04 Th-229 Am-241 1.000E+00 0.000E+00 2.221E-17 5.955E-16 2.151E-14 5.410E-13 1.579E-11 2.320E-10 1.807E-09 Th-229 Np-237 1.000E+00 0.000E+00 2.062E-10 1.851E-09 2.036E-08 1.782E-07 1.798E-06 1.246E-05 6.357E-05 Th-229 Pu-241 1.000E+00 0.000E+00 8.827E-21 6.975E-19 7.907E-17 5.088E-15 3.180E-13 6.638E-12 5.859E-11 Th-229 Pu-241 2.450E-05 0.000E+00 5.391E-22 1.418E-20 4.810E-19 1.030E-17 2.020E-16 1.828E-15 1.024E-14 Th-229 S(j): 0.000E+00 2.062E-10 1.851E-09 2.036E-08 1.782E-07 1.798E-06 1.246E-05 6.357E-05 C-14 C-14 1.000E+00 1.000E+00 1.615E-02 4.167E-06 1.036E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Ce-144 Ce-144 1.000E+00 1.000E+00 4.104E-01 6.911E-02 1.355E-04 2.486E-12 2.080E-39 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 6.800E-08 1.436E-08 6.401E-10 1.197E-14 3.712E-28 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 1.840E-09 3.885E-10 1.732E-11 3.240E-16 1.004E-29 0.000E+00 0.000E+00 0.000E+00 Cm-242 S(j): 6.984E-08 1.475E-08 6.574E-10 1.230E-14 3.812E-28 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.840E-09 0.000E+00 7.336E-12 9.084E-12 8.674E-12 7.393E-12 4.227E-12 8.557E-13 3.193E-15 Pu-238 Pu-238 1.840E-09 1.840E-09 1.825E-09 1.796E-09 1.699E-09 1.448E-09 8.279E-10 1.676E-10 6.254E-13 Pu-238 S(j): 1.840E-09 1.833E-09 1.806E-09 1.707E-09 1.455E-09 8.321E-10 1.684E-10 6.286E-13 Cm-242 Cm-242 1.000E+00 1.000E+00 2.111E-01 9.413E-03 1.761E-07 5.459E-21 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.000E+00 0.000E+00 3.987E-03 4.937E-03 4.714E-03 4.018E-03 2.297E-03 4.650E-04 1.736E-06 U-234 Cm-242 1.000E+00 0.000E+00 7.066E-09 3.354E-08 1.277E-07 3.576E-07 8.171E-07 8.379E-07 9.911E-08 U-234 Pu-238 1.000E+00 0.000E+00 2.819E-06 8.360E-06 2.677E-05 7.169E-05 1.613E-04 1.648E-04 1.947E-05 U-234 Pu-242 9.999E-01 0.000E+00 2.194E-16 1.965E-15 2.148E-14 1.846E-13 1.747E-12 1.012E-11 3.011E-11 U-234 S(j): 0.000E+00 2.826E-06 8.394E-06 2.690E-05 7.204E-05 1.621E-04 1.656E-04 1.957E-05 Th-230 Cm-242 1.000E+00 0.000E+00 2.367E-14 3.826E-13 5.500E-12 5.001E-11 4.435E-10 2.078E-09 4.398E-09 Th-230 Pu-238 1.000E+00 0.000E+00 1.271E-11 1.135E-10 1.228E-09 1.025E-08 8.825E-08 4.101E-07 8.659E-07 Th-230 Pu-242 9.999E-01 0.000E+00 6.587E-22 1.772E-20 6.483E-19 1.691E-17 5.552E-16 1.080E-14 1.509E-13 Th-230 S(j): 0.000E+00 1.274E-11 1.139E-10 1.234E-09 1.030E-08 8.869E-08 4.122E-07 8.703E-07

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 54 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ra-226 Cm-242 1.000E+00 0.000E+00 2.738E-18 1.437E-16 7.512E-15 2.135E-13 6.477E-12 9.192E-11 5.240E-10 Ra-226 Pu-238 1.000E+00 0.000E+00 1.836E-15 4.922E-14 1.778E-12 4.470E-11 1.297E-09 1.818E-08 1.032E-07 Ra-226 Pu-242 9.999E-01 0.000E+00 7.132E-26 5.754E-24 7.006E-22 5.455E-20 5.872E-18 3.253E-16 1.221E-14 Ra-226 S(j): 0.000E+00 1.839E-15 4.936E-14 1.785E-12 4.492E-11 1.304E-09 1.827E-08 1.037E-07 Pb-210 Cm-242 1.000E+00 0.000E+00 1.770E-20 2.917E-18 5.235E-16 4.145E-14 3.072E-12 7.031E-11 4.847E-10 Pb-210 Pu-238 1.000E+00 0.000E+00 1.418E-17 1.128E-15 1.304E-13 8.829E-12 6.176E-10 1.391E-08 9.546E-08 Pb-210 Pu-242 9.999E-01 0.000E+00 4.411E-28 1.057E-25 4.141E-23 8.790E-21 2.364E-18 2.227E-16 1.073E-14 Pb-210 S(j): 0.000E+00 1.420E-17 1.130E-15 1.310E-13 8.870E-12 6.206E-10 1.398E-08 9.595E-08 Po-210 Cm-242 1.000E+00 0.000E+00 4.364E-21 1.515E-18 4.199E-16 3.838E-14 2.991E-12 6.936E-11 4.800E-10 Po-210 Pu-238 1.000E+00 0.000E+00 3.939E-18 6.196E-16 1.058E-13 8.185E-12 6.012E-10 1.372E-08 9.454E-08 Po-210 Pu-242 9.999E-01 0.000E+00 1.059E-28 5.252E-26 3.207E-23 8.003E-21 2.287E-18 2.192E-16 1.061E-14 Po-210 S(j): 0.000E+00 3.943E-18 6.212E-16 1.062E-13 8.223E-12 6.042E-10 1.379E-08 9.502E-08 Cm-243 Cm-243 2.400E-03 2.400E-03 2.342E-03 2.230E-03 1.879E-03 1.153E-03 2.082E-04 1.567E-06 5.795E-14 Cm-243 Cm-243 9.976E-01 9.976E-01 9.735E-01 9.271E-01 7.812E-01 4.791E-01 8.654E-02 6.513E-04 2.409E-11 Cm-243 S(j): 1.000E+00 9.758E-01 9.293E-01 7.831E-01 4.803E-01 8.675E-02 6.529E-04 2.415E-11 Am-243 Cm-243 2.400E-03 0.000E+00 2.217E-07 6.435E-07 1.912E-06 4.153E-06 4.761E-06 1.048E-06 2.425E-09 Pu-239 Cm-243 2.400E-03 0.000E+00 3.211E-12 2.826E-11 2.909E-10 2.119E-09 1.208E-08 2.654E-08 2.774E-08 Pu-239 Cm-243 9.976E-01 0.000E+00 2.838E-05 8.310E-05 2.548E-04 6.097E-04 1.065E-03 1.140E-03 1.052E-03 Pu-239 Pu-239 1.000E+00 1.000E+00 9.999E-01 9.997E-01 9.988E-01 9.965E-01 9.885E-01 9.659E-01 8.908E-01 Pu-239 S(j): 1.000E+00 9.999E-01 9.997E-01 9.991E-01 9.971E-01 9.896E-01 9.671E-01 8.919E-01 U-235 Cm-243 2.400E-03 0.000E+00 1.056E-21 2.800E-20 9.731E-19 2.202E-17 4.611E-16 3.352E-15 7.630E-15 U-235 Cm-243 9.976E-01 0.000E+00 1.402E-14 1.238E-13 1.291E-12 9.745E-12 6.332E-11 1.932E-10 2.973E-10 U-235 Pu-239 1.000E+00 0.000E+00 9.831E-10 2.939E-09 9.675E-09 2.802E-08 8.276E-08 1.802E-07 2.533E-07 U-235 S(j): 0.000E+00 9.831E-10 2.939E-09 9.676E-09 2.803E-08 8.282E-08 1.804E-07 2.536E-07 Pa-231 Cm-243 2.400E-03 0.000E+00 5.592E-27 4.458E-25 5.205E-23 3.608E-21 2.671E-19 6.288E-18 3.927E-17 Pa-231 Cm-243 9.976E-01 0.000E+00 9.901E-20 2.632E-18 9.232E-17 2.145E-15 4.933E-14 4.587E-13 1.619E-12 Pa-231 Pu-239 1.000E+00 0.000E+00 1.039E-14 9.311E-14 1.018E-12 8.741E-12 8.263E-11 4.770E-10 1.400E-09 Pa-231 S(j): 0.000E+00 1.039E-14 9.312E-14 1.018E-12 8.743E-12 8.268E-11 4.775E-10 1.402E-09 Ac-227 Cm-243 2.400E-03 0.000E+00 3.541E-29 8.378E-27 3.143E-24 5.905E-22 1.070E-19 4.074E-18 3.041E-17 Ac-227 Cm-243 9.976E-01 0.000E+00 7.829E-22 6.163E-20 6.892E-18 4.253E-16 2.261E-14 3.137E-13 1.261E-12 Ac-227 Pu-239 1.000E+00 0.000E+00 1.093E-16 2.882E-15 9.845E-14 2.140E-12 4.208E-11 3.338E-10 1.092E-09 Ac-227 S(j): 0.000E+00 1.093E-16 2.882E-15 9.846E-14 2.140E-12 4.211E-11 3.341E-10 1.094E-09 Co-57 Co-57 1.000E+00 1.000E+00 3.927E-01 6.056E-02 8.720E-05 6.630E-13 2.542E-41 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 1.000E+00 2.799E-02 2.192E-05 2.947E-16 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Co-60 Co-60 1.000E+00 1.000E+00 8.766E-01 6.737E-01 2.680E-01 1.925E-02 1.912E-06 6.986E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 1.000E+00 7.145E-01 3.647E-01 3.467E-02 4.167E-05 2.509E-15 1.541E-44 0.000E+00 Cs-137 Cs-137 1.000E+00 1.000E+00 9.771E-01 9.329E-01 7.934E-01 4.994E-01 9.884E-02 9.656E-04 8.898E-11

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 55 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Eu-154 Eu-154 1.000E+00 1.000E+00 9.241E-01 7.890E-01 4.539E-01 9.354E-02 3.716E-04 5.131E-11 5.020E-35 Fe-55 Fe-55 1.000E+00 1.000E+00 7.734E-01 4.627E-01 7.662E-02 4.497E-04 6.970E-12 3.385E-34 0.000E+00 H-3 H-3 1.000E+00 1.000E+00 1.881E-01 6.643E-03 5.357E-08 1.201E-22 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 1.000E+00 5.766E-01 1.917E-01 4.062E-03 6.703E-08 1.224E-24 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 1.000E+00 4.444E-01 8.777E-02 3.005E-04 2.713E-11 5.997E-36 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 1.000E+00 4.465E-01 8.900E-02 3.148E-04 3.119E-11 9.553E-36 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.000E+00 9.998E-01 9.995E-01 9.982E-01 9.945E-01 9.819E-01 9.466E-01 8.329E-01 Ni-63 Ni-63 1.000E+00 1.000E+00 9.926E-01 9.781E-01 9.287E-01 8.011E-01 4.774E-01 1.088E-01 6.150E-04 Pu-238 Pu-238 1.000E+00 1.000E+00 9.920E-01 9.763E-01 9.232E-01 7.869E-01 4.499E-01 9.108E-02 3.399E-04 Pu-241 Pu-241 1.000E+00 1.000E+00 9.529E-01 8.653E-01 6.174E-01 2.353E-01 8.049E-03 5.215E-07 1.141E-21 Pu-241 Pu-241 2.450E-05 2.450E-05 2.335E-05 2.120E-05 1.513E-05 5.766E-06 1.972E-07 1.278E-11 2.796E-26 Pu-241 S(j): 1.000E+00 9.529E-01 8.653E-01 6.174E-01 2.354E-01 8.049E-03 5.215E-07 1.141E-21 Pu-242 Pu-242 5.500E-06 5.500E-06 5.500E-06 5.499E-06 5.495E-06 5.485E-06 5.451E-06 5.356E-06 5.033E-06 Pu-242 Pu-242 5.400E-05 5.400E-05 5.399E-05 5.399E-05 5.395E-05 5.386E-05 5.352E-05 5.258E-05 4.942E-05 Pu-242 S(j): 5.950E-05 5.949E-05 5.948E-05 5.945E-05 5.934E-05 5.897E-05 5.794E-05 5.445E-05 U-238 Pu-242 5.400E-05 0.000E+00 8.362E-15 2.500E-14 8.230E-14 2.384E-13 7.049E-13 1.540E-12 2.197E-12 U-238 Pu-242 9.999E-01 0.000E+00 1.549E-10 4.629E-10 1.524E-09 4.415E-09 1.305E-08 2.852E-08 4.069E-08 U-238 S(j): 0.000E+00 1.549E-10 4.629E-10 1.524E-09 4.415E-09 1.305E-08 2.852E-08 4.069E-08 Pu-242 Pu-242 9.999E-01 9.999E-01 9.999E-01 9.997E-01 9.991E-01 9.973E-01 9.911E-01 9.737E-01 9.151E-01 Ru-106 Ru-106 1.000E+00 1.000E+00 2.245E-01 1.131E-02 3.251E-07 3.435E-20 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 1.000E+00 6.659E-03 2.952E-07 1.713E-22 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 7.720E-01 2.684E-01 3.244E-02 1.991E-05 1.324E-14 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 2.280E-01 7.926E-02 9.580E-03 5.880E-06 3.910E-15 0.000E+00 0.000E+00 0.000E+00 Sb-125 S(j): 1.000E+00 3.476E-01 4.202E-02 2.579E-05 1.715E-14 0.000E+00 0.000E+00 0.000E+00 Te-125m Sb-125 2.280E-01 0.000E+00 8.271E-02 1.016E-02 6.237E-06 4.148E-15 0.000E+00 0.000E+00 0.000E+00 Sn-113 Sn-113 1.000E+00 1.000E+00 4.949E-02 1.212E-04 8.821E-14 6.863E-40 0.000E+00 0.000E+00 0.000E+00 Sr-90 Sr-90 1.000E+00 1.000E+00 9.709E-01 9.152E-01 7.442E-01 4.121E-01 5.208E-02 1.413E-04 1.469E-13 Tc-99 Tc-99 1.000E+00 1.000E+00 4.465E-01 8.901E-02 3.149E-04 3.122E-11 9.582E-36 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 1.000E+00 1.581E-01 3.954E-03 9.775E-09 9.340E-25 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:39 Page 56 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413FARMER.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95 Zr-95 1.000E+00 1.000E+00 1.912E-02 6.988E-06 6.523E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Nb-95 Zr-95 1.000E+00 0.000E+00 3.339E-02 1.242E-05 1.160E-17 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

RESCALC.EXE execution time = 123.91 seconds Total water/soil iteration failures = 1.

DRE-13-001 Revision 1 SRRS: 2B.134 ENCLOSURE 5 RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Industrial Worker Scenario (54 pages total)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 1 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary... 2 Site-Specific Parameter Summary.......................... 13 Summary of Pathway Selections............................ 24 Contaminated Zone and Total Dose Summary................. 25 Total Dose Components Time = 0.000E+00.................................... 26 Time = 1.000E+00.................................... 28 Time = 3.000E+00.................................... 30 Time = 1.000E+01.................................... 32 Time = 3.000E+01.................................... 34 Time = 1.000E+02.................................... 36 Time = 3.000E+02.................................... 38 Time = 1.000E+03.................................... 40 Dose/Source Ratios Summed Over All Pathways.............. 42 Single Radionuclide Soil Guidelines...................... 45 Dose Per Nuclide Summed Over All Pathways................ 47 Soil Concentration Per Nuclide........................... 51

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 2 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ A-1 ³ DCF's for external ground radiation, (mrem/yr)/(pCi/g) ³ ³ ³ A-1 ³ Ac-225 (Source: FGR 12) ³ 6.371E-02 ³ 6.371E-02 ³ DCF1( 1)

A-1 ³ Ac-227 (Source: FGR 12) ³ 4.951E-04 ³ 4.951E-04 ³ DCF1( 2)

A-1 ³ Ag-110 (Source: FGR 12) ³ 2.242E-01 ³ 2.242E-01 ³ DCF1( 3)

A-1 ³ Ag-110m (Source: FGR 12) ³ 1.717E+01 ³ 1.717E+01 ³ DCF1( 4)

A-1 ³ Am-241 (Source: FGR 12) ³ 4.372E-02 ³ 4.372E-02 ³ DCF1( 5)

A-1 ³ Am-243 (Source: FGR 12) ³ 1.420E-01 ³ 1.420E-01 ³ DCF1( 6)

A-1 ³ At-217 (Source: FGR 12) ³ 1.773E-03 ³ 1.773E-03 ³ DCF1( 7)

A-1 ³ At-218 (Source: FGR 12) ³ 5.847E-03 ³ 5.847E-03 ³ DCF1( 8)

A-1 ³ Ba-137m (Source: FGR 12) ³ 3.606E+00 ³ 3.606E+00 ³ DCF1( 9)

A-1 ³ Bi-210 (Source: FGR 12) ³ 3.606E-03 ³ 3.606E-03 ³ DCF1( 10)

A-1 ³ Bi-211 (Source: FGR 12) ³ 2.559E-01 ³ 2.559E-01 ³ DCF1( 11)

A-1 ³ Bi-213 (Source: FGR 12) ³ 7.660E-01 ³ 7.660E-01 ³ DCF1( 12)

A-1 ³ Bi-214 (Source: FGR 12) ³ 9.808E+00 ³ 9.808E+00 ³ DCF1( 13)

A-1 ³ C-14 (Source: FGR 12) ³ 1.345E-05 ³ 1.345E-05 ³ DCF1( 14)

A-1 ³ Ce-144 (Source: FGR 12) ³ 7.174E-02 ³ 7.174E-02 ³ DCF1( 15)

A-1 ³ Cm-242 (Source: FGR 12) ³ 1.709E-04 ³ 1.709E-04 ³ DCF1( 16)

A-1 ³ Cm-243 (Source: FGR 12) ³ 5.829E-01 ³ 5.829E-01 ³ DCF1( 17)

A-1 ³ Co-57 (Source: FGR 12) ³ 5.007E-01 ³ 5.007E-01 ³ DCF1( 18)

A-1 ³ Co-58 (Source: FGR 12) ³ 5.960E+00 ³ 5.960E+00 ³ DCF1( 19)

A-1 ³ Co-60 (Source: FGR 12) ³ 1.622E+01 ³ 1.622E+01 ³ DCF1( 20)

A-1 ³ Cs-134 (Source: FGR 12) ³ 9.472E+00 ³ 9.472E+00 ³ DCF1( 21)

A-1 ³ Cs-137 (Source: FGR 12) ³ 7.510E-04 ³ 7.510E-04 ³ DCF1( 22)

A-1 ³ Eu-154 (Source: FGR 12) ³ 7.678E+00 ³ 7.678E+00 ³ DCF1( 23)

A-1 ³ Fe-55 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 24)

A-1 ³ Fr-221 (Source: FGR 12) ³ 1.536E-01 ³ 1.536E-01 ³ DCF1( 25)

A-1 ³ Fr-223 (Source: FGR 12) ³ 1.980E-01 ³ 1.980E-01 ³ DCF1( 26)

A-1 ³ H-3 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 27)

A-1 ³ I-129 (Source: FGR 12) ³ 1.295E-02 ³ 1.295E-02 ³ DCF1( 28)

A-1 ³ In-113m (Source: FGR 12) ³ 1.435E+00 ³ 1.435E+00 ³ DCF1( 29)

A-1 ³ Mn-54 (Source: FGR 12) ³ 5.156E+00 ³ 5.156E+00 ³ DCF1( 30)

A-1 ³ Nb-94 (Source: FGR 12) ³ 9.677E+00 ³ 9.677E+00 ³ DCF1( 31)

A-1 ³ Nb-95 (Source: FGR 12) ³ 4.689E+00 ³ 4.689E+00 ³ DCF1( 32)

A-1 ³ Nb-95m (Source: FGR 12) ³ 3.195E-01 ³ 3.195E-01 ³ DCF1( 33)

A-1 ³ Ni-59 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 34)

A-1 ³ Ni-63 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 35)

A-1 ³ Np-237 (Source: FGR 12) ³ 7.790E-02 ³ 7.790E-02 ³ DCF1( 36)

A-1 ³ Np-239 (Source: FGR 12) ³ 7.529E-01 ³ 7.529E-01 ³ DCF1( 37)

A-1 ³ Pa-231 (Source: FGR 12) ³ 1.906E-01 ³ 1.906E-01 ³ DCF1( 38)

A-1 ³ Pa-233 (Source: FGR 12) ³ 1.020E+00 ³ 1.020E+00 ³ DCF1( 39)

A-1 ³ Pa-234 (Source: FGR 12) ³ 1.155E+01 ³ 1.155E+01 ³ DCF1( 40)

A-1 ³ Pa-234m (Source: FGR 12) ³ 8.967E-02 ³ 8.967E-02 ³ DCF1( 41)

A-1 ³ Pb-209 (Source: FGR 12) ³ 7.734E-04 ³ 7.734E-04 ³ DCF1( 42)

A-1 ³ Pb-210 (Source: FGR 12) ³ 2.447E-03 ³ 2.447E-03 ³ DCF1( 43)

A-1 ³ Pb-211 (Source: FGR 12) ³ 3.064E-01 ³ 3.064E-01 ³ DCF1( 44)

A-1 ³ Pb-214 (Source: FGR 12) ³ 1.341E+00 ³ 1.341E+00 ³ DCF1( 45)

A-1 ³ Po-210 (Source: FGR 12) ³ 5.231E-05 ³ 5.231E-05 ³ DCF1( 46)

A-1 ³ Po-211 (Source: FGR 12) ³ 4.764E-02 ³ 4.764E-02 ³ DCF1( 47)

A-1 ³ Po-213 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 48)

A-1 ³ Po-214 (Source: FGR 12) ³ 5.138E-04 ³ 5.138E-04 ³ DCF1( 49)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 3 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ A-1 ³ Po-215 (Source: FGR 12) ³ 1.016E-03 ³ 1.016E-03 ³ DCF1( 50)

A-1 ³ Po-218 (Source: FGR 12) ³ 5.642E-05 ³ 5.642E-05 ³ DCF1( 51)

A-1 ³ Pr-144 (Source: FGR 12) ³ 2.522E-01 ³ 2.522E-01 ³ DCF1( 52)

A-1 ³ Pr-144m (Source: FGR 12) ³ 1.437E-02 ³ 1.437E-02 ³ DCF1( 53)

A-1 ³ Pu-238 (Source: FGR 12) ³ 1.513E-04 ³ 1.513E-04 ³ DCF1( 54)

A-1 ³ Pu-239 (Source: FGR 12) ³ 2.952E-04 ³ 2.952E-04 ³ DCF1( 55)

A-1 ³ Pu-241 (Source: FGR 12) ³ 5.904E-06 ³ 5.904E-06 ³ DCF1( 56)

A-1 ³ Pu-242 (Source: FGR 12) ³ 1.280E-04 ³ 1.280E-04 ³ DCF1( 57)

A-1 ³ Ra-223 (Source: FGR 12) ³ 6.034E-01 ³ 6.034E-01 ³ DCF1( 58)

A-1 ³ Ra-225 (Source: FGR 12) ³ 1.102E-02 ³ 1.102E-02 ³ DCF1( 59)

A-1 ³ Ra-226 (Source: FGR 12) ³ 3.176E-02 ³ 3.176E-02 ³ DCF1( 60)

A-1 ³ Rh-106 (Source: FGR 12) ³ 1.291E+00 ³ 1.291E+00 ³ DCF1( 61)

A-1 ³ Rn-219 (Source: FGR 12) ³ 3.083E-01 ³ 3.083E-01 ³ DCF1( 62)

A-1 ³ Rn-222 (Source: FGR 12) ³ 2.354E-03 ³ 2.354E-03 ³ DCF1( 63)

A-1 ³ Ru-106 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 64)

A-1 ³ Sb-124 (Source: FGR 12) ³ 1.169E+01 ³ 1.169E+01 ³ DCF1( 65)

A-1 ³ Sb-125 (Source: FGR 12) ³ 2.447E+00 ³ 2.447E+00 ³ DCF1( 66)

A-1 ³ Sn-113 (Source: FGR 12) ³ 2.970E-02 ³ 2.970E-02 ³ DCF1( 67)

A-1 ³ Sr-90 (Source: FGR 12) ³ 7.043E-04 ³ 7.043E-04 ³ DCF1( 68)

A-1 ³ Tc-99 (Source: FGR 12) ³ 1.255E-04 ³ 1.255E-04 ³ DCF1( 69)

A-1 ³ Te-125m (Source: FGR 12) ³ 1.515E-02 ³ 1.515E-02 ³ DCF1( 70)

A-1 ³ Th-227 (Source: FGR 12) ³ 5.212E-01 ³ 5.212E-01 ³ DCF1( 71)

A-1 ³ Th-229 (Source: FGR 12) ³ 3.213E-01 ³ 3.213E-01 ³ DCF1( 72)

A-1 ³ Th-230 (Source: FGR 12) ³ 1.209E-03 ³ 1.209E-03 ³ DCF1( 73)

A-1 ³ Th-231 (Source: FGR 12) ³ 3.643E-02 ³ 3.643E-02 ³ DCF1( 74)

A-1 ³ Th-234 (Source: FGR 12) ³ 2.410E-02 ³ 2.410E-02 ³ DCF1( 75)

A-1 ³ Tl-207 (Source: FGR 12) ³ 1.980E-02 ³ 1.980E-02 ³ DCF1( 76)

A-1 ³ Tl-209 (Source: FGR 12) ³ 1.293E+01 ³ 1.293E+01 ³ DCF1( 77)

A-1 ³ Tl-210 (Source: no data) ³ 0.000E+00 ³-2.000E+00 ³ DCF1( 78)

A-1 ³ U-233 (Source: FGR 12) ³ 1.397E-03 ³ 1.397E-03 ³ DCF1( 79)

A-1 ³ U-234 (Source: FGR 12) ³ 4.017E-04 ³ 4.017E-04 ³ DCF1( 80)

A-1 ³ U-235 (Source: FGR 12) ³ 7.211E-01 ³ 7.211E-01 ³ DCF1( 81)

A-1 ³ U-237 (Source: FGR 12) ³ 5.306E-01 ³ 5.306E-01 ³ DCF1( 82)

A-1 ³ U-238 (Source: FGR 12) ³ 1.031E-04 ³ 1.031E-04 ³ DCF1( 83)

A-1 ³ Y-90 (Source: FGR 12) ³ 2.391E-02 ³ 2.391E-02 ³ DCF1( 84)

A-1 ³ Zn-65 (Source: FGR 12) ³ 3.699E+00 ³ 3.699E+00 ³ DCF1( 85)

A-1 ³ Zr-95 (Source: FGR 12) ³ 4.521E+00 ³ 4.521E+00 ³ DCF1( 86)

³ ³ ³ ³ B-1 ³ Dose conversion factors for inhalation, mrem/pCi: ³ ³ ³ B-1 ³ Ac-227+D ³ 6.724E+00 ³ 6.700E+00 ³ DCF2( 1)

B-1 ³ Ag-110m+D ³ 8.030E-05 ³ 8.030E-05 ³ DCF2( 2)

B-1 ³ Am-241 ³ 4.440E-01 ³ 4.440E-01 ³ DCF2( 3)

B-1 ³ Am-243+D ³ 4.400E-01 ³ 4.400E-01 ³ DCF2( 4)

B-1 ³ C-14(p) (Class: ORGANIC) ³ 2.090E-06 ³ 2.090E-06 ³ DCF2( 5)

B-1 ³ C-14(g) (Class: CO2) ³ 2.350E-08 ³ 2.350E-08 ³ C14GInhDCF B-1 ³ Ce-144+D ³ 3.740E-04 ³ 3.740E-04 ³ DCF2( 6)

B-1 ³ Cm-242 ³ 1.730E-02 ³ 1.730E-02 ³ DCF2( 7)

B-1 ³ Cm-243 ³ 3.070E-01 ³ 3.070E-01 ³ DCF2( 10)

B-1 ³ Co-57 ³ 9.070E-06 ³ 9.070E-06 ³ DCF2( 12)

B-1 ³ Co-58 ³ 1.090E-05 ³ 1.090E-05 ³ DCF2( 13)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 4 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ B-1 ³ Co-60 ³ 2.190E-04 ³ 2.190E-04 ³ DCF2( 14)

B-1 ³ Cs-134 ³ 4.620E-05 ³ 4.620E-05 ³ DCF2( 15)

B-1 ³ Cs-137+D ³ 3.190E-05 ³ 3.190E-05 ³ DCF2( 16)

B-1 ³ Eu-154 ³ 2.860E-04 ³ 2.860E-04 ³ DCF2( 17)

B-1 ³ Fe-55 ³ 2.690E-06 ³ 2.690E-06 ³ DCF2( 18)

B-1 ³ H-3 ³ 6.400E-08 ³ 6.400E-08 ³ DCF2( 19)

B-1 ³ I-129 ³ 1.740E-04 ³ 1.740E-04 ³ DCF2( 20)

B-1 ³ Mn-54 ³ 6.700E-06 ³ 6.700E-06 ³ DCF2( 21)

B-1 ³ Nb-94 ³ 4.140E-04 ³ 4.140E-04 ³ DCF2( 22)

B-1 ³ Nb-95 ³ 5.810E-06 ³ 5.810E-06 ³ DCF2( 23)

B-1 ³ Ni-59 ³ 2.700E-06 ³ 2.700E-06 ³ DCF2( 24)

B-1 ³ Ni-63 ³ 6.290E-06 ³ 6.290E-06 ³ DCF2( 25)

B-1 ³ Np-237+D ³ 5.400E-01 ³ 5.400E-01 ³ DCF2( 26)

B-1 ³ Pa-231 ³ 1.280E+00 ³ 1.280E+00 ³ DCF2( 27)

B-1 ³ Pb-210+D ³ 1.380E-02 ³ 1.360E-02 ³ DCF2( 28)

B-1 ³ Po-210 ³ 9.400E-03 ³ 9.400E-03 ³ DCF2( 29)

B-1 ³ Pu-238 ³ 3.920E-01 ³ 3.920E-01 ³ DCF2( 30)

B-1 ³ Pu-239 ³ 4.290E-01 ³ 4.290E-01 ³ DCF2( 32)

B-1 ³ Pu-241 ³ 8.250E-03 ³ 8.250E-03 ³ DCF2( 33)

B-1 ³ Pu-241+D ³ 8.254E-03 ³ 8.250E-03 ³ DCF2( 34)

B-1 ³ Pu-242 ³ 4.110E-01 ³ 4.110E-01 ³ DCF2( 35)

B-1 ³ Ra-226+D ³ 8.594E-03 ³ 8.580E-03 ³ DCF2( 38)

B-1 ³ Ru-106+D ³ 4.770E-04 ³ 4.770E-04 ³ DCF2( 39)

B-1 ³ Sb-124 ³ 2.520E-05 ³ 2.520E-05 ³ DCF2( 40)

B-1 ³ Sb-125 ³ 1.220E-05 ³ 1.220E-05 ³ DCF2( 41)

B-1 ³ Sn-113+D ³ 1.074E-05 ³ 1.070E-05 ³ DCF2( 43)

B-1 ³ Sr-90+D ³ 1.308E-03 ³ 1.300E-03 ³ DCF2( 44)

B-1 ³ Tc-99 ³ 8.320E-06 ³ 8.320E-06 ³ DCF2( 45)

B-1 ³ Te-125m ³ 7.290E-06 ³ 7.290E-06 ³ DCF2( 46)

B-1 ³ Th-229+D ³ 2.169E+00 ³ 2.150E+00 ³ DCF2( 47)

B-1 ³ Th-230 ³ 3.260E-01 ³ 3.260E-01 ³ DCF2( 48)

B-1 ³ U-233 ³ 1.350E-01 ³ 1.350E-01 ³ DCF2( 49)

B-1 ³ U-234 ³ 1.320E-01 ³ 1.320E-01 ³ DCF2( 50)

B-1 ³ U-235+D ³ 1.230E-01 ³ 1.230E-01 ³ DCF2( 51)

B-1 ³ U-238 ³ 1.180E-01 ³ 1.180E-01 ³ DCF2( 52)

B-1 ³ U-238+D ³ 1.180E-01 ³ 1.180E-01 ³ DCF2( 53)

B-1 ³ Zn-65 ³ 2.040E-05 ³ 2.040E-05 ³ DCF2( 54)

B-1 ³ Zr-95+D ³ 2.362E-05 ³ 2.360E-05 ³ DCF2( 55)

³ ³ ³ ³ D-1 ³ Dose conversion factors for ingestion, mrem/pCi: ³ ³ ³ D-1 ³ Ac-227+D ³ 1.480E-02 ³ 1.410E-02 ³ DCF3( 1)

D-1 ³ Ag-110m+D ³ 1.080E-05 ³ 1.080E-05 ³ DCF3( 2)

D-1 ³ Am-241 ³ 3.640E-03 ³ 3.640E-03 ³ DCF3( 3)

D-1 ³ Am-243+D ³ 3.623E-03 ³ 3.620E-03 ³ DCF3( 4)

D-1 ³ C-14 ³ 2.090E-06 ³ 2.090E-06 ³ DCF3( 5)

D-1 ³ Ce-144+D ³ 2.112E-05 ³ 2.100E-05 ³ DCF3( 6)

D-1 ³ Cm-242 ³ 1.150E-04 ³ 1.150E-04 ³ DCF3( 7)

D-1 ³ Cm-243 ³ 2.510E-03 ³ 2.510E-03 ³ DCF3( 10)

D-1 ³ Co-57 ³ 1.180E-06 ³ 1.180E-06 ³ DCF3( 12)

D-1 ³ Co-58 ³ 3.580E-06 ³ 3.580E-06 ³ DCF3( 13)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 5 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-1 ³ Co-60 ³ 2.690E-05 ³ 2.690E-05 ³ DCF3( 14)

D-1 ³ Cs-134 ³ 7.330E-05 ³ 7.330E-05 ³ DCF3( 15)

D-1 ³ Cs-137+D ³ 5.000E-05 ³ 5.000E-05 ³ DCF3( 16)

D-1 ³ Eu-154 ³ 9.550E-06 ³ 9.550E-06 ³ DCF3( 17)

D-1 ³ Fe-55 ³ 6.070E-07 ³ 6.070E-07 ³ DCF3( 18)

D-1 ³ H-3 ³ 6.400E-08 ³ 6.400E-08 ³ DCF3( 19)

D-1 ³ I-129 ³ 2.760E-04 ³ 2.760E-04 ³ DCF3( 20)

D-1 ³ Mn-54 ³ 2.770E-06 ³ 2.770E-06 ³ DCF3( 21)

D-1 ³ Nb-94 ³ 7.140E-06 ³ 7.140E-06 ³ DCF3( 22)

D-1 ³ Nb-95 ³ 2.570E-06 ³ 2.570E-06 ³ DCF3( 23)

D-1 ³ Ni-59 ³ 2.100E-07 ³ 2.100E-07 ³ DCF3( 24)

D-1 ³ Ni-63 ³ 5.770E-07 ³ 5.770E-07 ³ DCF3( 25)

D-1 ³ Np-237+D ³ 4.444E-03 ³ 4.440E-03 ³ DCF3( 26)

D-1 ³ Pa-231 ³ 1.060E-02 ³ 1.060E-02 ³ DCF3( 27)

D-1 ³ Pb-210+D ³ 5.376E-03 ³ 5.370E-03 ³ DCF3( 28)

D-1 ³ Po-210 ³ 1.900E-03 ³ 1.900E-03 ³ DCF3( 29)

D-1 ³ Pu-238 ³ 3.200E-03 ³ 3.200E-03 ³ DCF3( 30)

D-1 ³ Pu-239 ³ 3.540E-03 ³ 3.540E-03 ³ DCF3( 32)

D-1 ³ Pu-241 ³ 6.840E-05 ³ 6.840E-05 ³ DCF3( 33)

D-1 ³ Pu-241+D ³ 7.157E-05 ³ 6.840E-05 ³ DCF3( 34)

D-1 ³ Pu-242 ³ 3.360E-03 ³ 3.360E-03 ³ DCF3( 35)

D-1 ³ Ra-226+D ³ 1.321E-03 ³ 1.320E-03 ³ DCF3( 38)

D-1 ³ Ru-106+D ³ 2.740E-05 ³ 2.740E-05 ³ DCF3( 39)

D-1 ³ Sb-124 ³ 1.010E-05 ³ 1.010E-05 ³ DCF3( 40)

D-1 ³ Sb-125 ³ 2.810E-06 ³ 2.810E-06 ³ DCF3( 41)

D-1 ³ Sn-113+D ³ 3.185E-06 ³ 3.080E-06 ³ DCF3( 43)

D-1 ³ Sr-90+D ³ 1.528E-04 ³ 1.420E-04 ³ DCF3( 44)

D-1 ³ Tc-99 ³ 1.460E-06 ³ 1.460E-06 ³ DCF3( 45)

D-1 ³ Te-125m ³ 3.670E-06 ³ 3.670E-06 ³ DCF3( 46)

D-1 ³ Th-229+D ³ 4.027E-03 ³ 3.530E-03 ³ DCF3( 47)

D-1 ³ Th-230 ³ 5.480E-04 ³ 5.480E-04 ³ DCF3( 48)

D-1 ³ U-233 ³ 2.890E-04 ³ 2.890E-04 ³ DCF3( 49)

D-1 ³ U-234 ³ 2.830E-04 ³ 2.830E-04 ³ DCF3( 50)

D-1 ³ U-235+D ³ 2.673E-04 ³ 2.660E-04 ³ DCF3( 51)

D-1 ³ U-238 ³ 2.550E-04 ³ 2.550E-04 ³ DCF3( 52)

D-1 ³ U-238+D ³ 2.687E-04 ³ 2.550E-04 ³ DCF3( 53)

D-1 ³ Zn-65 ³ 1.440E-05 ³ 1.440E-05 ³ DCF3( 54)

D-1 ³ Zr-95+D ³ 3.786E-06 ³ 3.770E-06 ³ DCF3( 55)

³ ³ ³ ³ D-34 ³ Food transfer factors: ³ ³ ³ D-34 ³ Ac-227+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 1,1)

D-34 ³ Ac-227+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 1,2)

D-34 ³ Ac-227+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 1,3)

D-34 ³ ³ ³ ³ D-34 ³ Ag-110m+D, plant/soil concentration ratio, dimensionless ³ 1.500E-01 ³ 1.500E-01 ³ RTF( 2,1)

D-34 ³ Ag-110m+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-03 ³ 3.000E-03 ³ RTF( 2,2)

D-34 ³ Ag-110m+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.500E-02 ³ 2.500E-02 ³ RTF( 2,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 6 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Am-241, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 3,1)

D-34 ³ Am-241, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 3,2)

D-34 ³ Am-241, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 3,3)

D-34 ³ ³ ³ ³ D-34 ³ Am-243+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 4,1)

D-34 ³ Am-243+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 4,2)

D-34 ³ Am-243+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 4,3)

D-34 ³ ³ ³ ³ D-34 ³ C-14, plant/soil concentration ratio, dimensionless ³ 5.500E+00 ³ 5.500E+00 ³ RTF( 5,1)

D-34 ³ C-14, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.100E-02 ³ 3.100E-02 ³ RTF( 5,2)

D-34 ³ C-14, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.200E-02 ³ 1.200E-02 ³ RTF( 5,3)

D-34 ³ ³ ³ ³ D-34 ³ Ce-144+D, plant/soil concentration ratio, dimensionless ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 6,1)

D-34 ³ Ce-144+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 6,2)

D-34 ³ Ce-144+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 6,3)

D-34 ³ ³ ³ ³ D-34 ³ Cm-242, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 7,1)

D-34 ³ Cm-242, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 7,2)

D-34 ³ Cm-242, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 7,3)

D-34 ³ ³ ³ ³ D-34 ³ Cm-243, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 10,1)

D-34 ³ Cm-243, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 10,2)

D-34 ³ Cm-243, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 10,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-57, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 12,1)

D-34 ³ Co-57, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 12,2)

D-34 ³ Co-57, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 12,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-58, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 13,1)

D-34 ³ Co-58, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 13,2)

D-34 ³ Co-58, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 13,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-60, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 14,1)

D-34 ³ Co-60, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 14,2)

D-34 ³ Co-60, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 14,3)

D-34 ³ ³ ³ ³ D-34 ³ Cs-134, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 15,1)

D-34 ³ Cs-134, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 15,2)

D-34 ³ Cs-134, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 15,3)

D-34 ³ ³ ³ ³ D-34 ³ Cs-137+D, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 16,1)

D-34 ³ Cs-137+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 16,2)

D-34 ³ Cs-137+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 16,3)

D-34 ³ ³ ³ ³ D-34 ³ Eu-154, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 17,1)

D-34 ³ Eu-154, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 17,2)

D-34 ³ Eu-154, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 17,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 7 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Fe-55, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 18,1)

D-34 ³ Fe-55, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 18,2)

D-34 ³ Fe-55, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 18,3)

D-34 ³ ³ ³ ³ D-34 ³ H-3, plant/soil concentration ratio, dimensionless ³ 4.800E+00 ³ 4.800E+00 ³ RTF( 19,1)

D-34 ³ H-3, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.200E-02 ³ 1.200E-02 ³ RTF( 19,2)

D-34 ³ H-3, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 19,3)

D-34 ³ ³ ³ ³ D-34 ³ I-129, plant/soil concentration ratio, dimensionless ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 20,1)

D-34 ³ I-129, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 7.000E-03 ³ 7.000E-03 ³ RTF( 20,2)

D-34 ³ I-129, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 20,3)

D-34 ³ ³ ³ ³ D-34 ³ Mn-54, plant/soil concentration ratio, dimensionless ³ 3.000E-01 ³ 3.000E-01 ³ RTF( 21,1)

D-34 ³ Mn-54, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-04 ³ 5.000E-04 ³ RTF( 21,2)

D-34 ³ Mn-54, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 21,3)

D-34 ³ ³ ³ ³ D-34 ³ Nb-94, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 22,1)

D-34 ³ Nb-94, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-07 ³ 3.000E-07 ³ RTF( 22,2)

D-34 ³ Nb-94, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 22,3)

D-34 ³ ³ ³ ³ D-34 ³ Nb-95, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 23,1)

D-34 ³ Nb-95, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-07 ³ 3.000E-07 ³ RTF( 23,2)

D-34 ³ Nb-95, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 23,3)

D-34 ³ ³ ³ ³ D-34 ³ Ni-59, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 24,1)

D-34 ³ Ni-59, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 24,2)

D-34 ³ Ni-59, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 24,3)

D-34 ³ ³ ³ ³ D-34 ³ Ni-63, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 25,1)

D-34 ³ Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 25,2)

D-34 ³ Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 25,3)

D-34 ³ ³ ³ ³ D-34 ³ Np-237+D, plant/soil concentration ratio, dimensionless ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 26,1)

D-34 ³ Np-237+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 26,2)

D-34 ³ Np-237+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 26,3)

D-34 ³ ³ ³ ³ D-34 ³ Pa-231, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 27,1)

D-34 ³ Pa-231, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 27,2)

D-34 ³ Pa-231, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 27,3)

D-34 ³ ³ ³ ³ D-34 ³ Pb-210+D, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 28,1)

D-34 ³ Pb-210+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 8.000E-04 ³ 8.000E-04 ³ RTF( 28,2)

D-34 ³ Pb-210+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 28,3)

D-34 ³ ³ ³ ³ D-34 ³ Po-210, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 29,1)

D-34 ³ Po-210, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 29,2)

D-34 ³ Po-210, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 29,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 8 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Pu-238, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 30,1)

D-34 ³ Pu-238, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 30,2)

D-34 ³ Pu-238, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 30,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-239, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 32,1)

D-34 ³ Pu-239, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 32,2)

D-34 ³ Pu-239, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 32,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-241, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 33,1)

D-34 ³ Pu-241, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 33,2)

D-34 ³ Pu-241, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 33,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-241+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 34,1)

D-34 ³ Pu-241+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 34,2)

D-34 ³ Pu-241+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 34,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-242, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 35,1)

D-34 ³ Pu-242, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 35,2)

D-34 ³ Pu-242, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 35,3)

D-34 ³ ³ ³ ³ D-34 ³ Ra-226+D, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 38,1)

D-34 ³ Ra-226+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 38,2)

D-34 ³ Ra-226+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 38,3)

D-34 ³ ³ ³ ³ D-34 ³ Ru-106+D, plant/soil concentration ratio, dimensionless ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 39,1)

D-34 ³ Ru-106+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 39,2)

D-34 ³ Ru-106+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.300E-06 ³ 3.300E-06 ³ RTF( 39,3)

D-34 ³ ³ ³ ³ D-34 ³ Sb-124, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 40,1)

D-34 ³ Sb-124, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 40,2)

D-34 ³ Sb-124, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 40,3)

D-34 ³ ³ ³ ³ D-34 ³ Sb-125, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 41,1)

D-34 ³ Sb-125, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 41,2)

D-34 ³ Sb-125, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 41,3)

D-34 ³ ³ ³ ³ D-34 ³ Sn-113+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 43,1)

D-34 ³ Sn-113+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 43,2)

D-34 ³ Sn-113+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 43,3)

D-34 ³ ³ ³ ³ D-34 ³ Sr-90+D, plant/soil concentration ratio, dimensionless ³ 3.000E-01 ³ 3.000E-01 ³ RTF( 44,1)

D-34 ³ Sr-90+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 44,2)

D-34 ³ Sr-90+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 44,3)

D-34 ³ ³ ³ ³ D-34 ³ Tc-99, plant/soil concentration ratio, dimensionless ³ 5.000E+00 ³ 5.000E+00 ³ RTF( 45,1)

D-34 ³ Tc-99, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 45,2)

D-34 ³ Tc-99, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 45,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 9 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Te-125m, plant/soil concentration ratio, dimensionless ³ 6.000E-01 ³ 6.000E-01 ³ RTF( 46,1)

D-34 ³ Te-125m, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 7.000E-03 ³ 7.000E-03 ³ RTF( 46,2)

D-34 ³ Te-125m, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-04 ³ 5.000E-04 ³ RTF( 46,3)

D-34 ³ ³ ³ ³ D-34 ³ Th-229+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 47,1)

D-34 ³ Th-229+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 47,2)

D-34 ³ Th-229+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 47,3)

D-34 ³ ³ ³ ³ D-34 ³ Th-230, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 48,1)

D-34 ³ Th-230, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 48,2)

D-34 ³ Th-230, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 48,3)

D-34 ³ ³ ³ ³ D-34 ³ U-233, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 49,1)

D-34 ³ U-233, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 49,2)

D-34 ³ U-233, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 49,3)

D-34 ³ ³ ³ ³ D-34 ³ U-234, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 50,1)

D-34 ³ U-234, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 50,2)

D-34 ³ U-234, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 50,3)

D-34 ³ ³ ³ ³ D-34 ³ U-235+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 51,1)

D-34 ³ U-235+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 51,2)

D-34 ³ U-235+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 51,3)

D-34 ³ ³ ³ ³ D-34 ³ U-238, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 52,1)

D-34 ³ U-238, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 52,2)

D-34 ³ U-238, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 52,3)

D-34 ³ ³ ³ ³ D-34 ³ U-238+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 53,1)

D-34 ³ U-238+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 53,2)

D-34 ³ U-238+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 53,3)

D-34 ³ ³ ³ ³ D-34 ³ Zn-65, plant/soil concentration ratio, dimensionless ³ 4.000E-01 ³ 4.000E-01 ³ RTF( 54,1)

D-34 ³ Zn-65, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-01 ³ 1.000E-01 ³ RTF( 54,2)

D-34 ³ Zn-65, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 54,3)

D-34 ³ ³ ³ ³ D-34 ³ Zr-95+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 55,1)

D-34 ³ Zr-95+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 55,2)

D-34 ³ Zr-95+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-07 ³ 6.000E-07 ³ RTF( 55,3)

³ ³ ³ ³ D-5 ³ Bioaccumulation factors, fresh water, L/kg: ³ ³ ³ D-5 ³ Ac-227+D, fish ³ 1.500E+01 ³ 1.500E+01 ³ BIOFAC( 1,1)

D-5 ³ Ac-227+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 1,2)

D-5 ³ ³ ³ ³ D-5 ³ Ag-110m+D, fish ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 2,1)

D-5 ³ Ag-110m+D, crustacea and mollusks ³ 7.700E+02 ³ 7.700E+02 ³ BIOFAC( 2,2)

D-5 ³ ³ ³ ³ D-5 ³ Am-241, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 3,1)

D-5 ³ Am-241, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 3,2)

D-5 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 10 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Am-243+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 4,1)

D-5 ³ Am-243+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 4,2)

D-5 ³ ³ ³ ³ D-5 ³ C-14, fish ³ 5.000E+04 ³ 5.000E+04 ³ BIOFAC( 5,1)

D-5 ³ C-14, crustacea and mollusks ³ 9.100E+03 ³ 9.100E+03 ³ BIOFAC( 5,2)

D-5 ³ ³ ³ ³ D-5 ³ Ce-144+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 6,1)

D-5 ³ Ce-144+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 6,2)

D-5 ³ ³ ³ ³ D-5 ³ Cm-242, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 7,1)

D-5 ³ Cm-242, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 7,2)

D-5 ³ ³ ³ ³ D-5 ³ Cm-243, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 10,1)

D-5 ³ Cm-243, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 10,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-57, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 12,1)

D-5 ³ Co-57, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 12,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-58, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 13,1)

D-5 ³ Co-58, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 13,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-60, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 14,1)

D-5 ³ Co-60, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 14,2)

D-5 ³ ³ ³ ³ D-5 ³ Cs-134, fish ³ 2.000E+03 ³ 2.000E+03 ³ BIOFAC( 15,1)

D-5 ³ Cs-134, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 15,2)

D-5 ³ ³ ³ ³ D-5 ³ Cs-137+D, fish ³ 2.000E+03 ³ 2.000E+03 ³ BIOFAC( 16,1)

D-5 ³ Cs-137+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 16,2)

D-5 ³ ³ ³ ³ D-5 ³ Eu-154, fish ³ 5.000E+01 ³ 5.000E+01 ³ BIOFAC( 17,1)

D-5 ³ Eu-154, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 17,2)

D-5 ³ ³ ³ ³ D-5 ³ Fe-55, fish ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 18,1)

D-5 ³ Fe-55, crustacea and mollusks ³ 3.200E+03 ³ 3.200E+03 ³ BIOFAC( 18,2)

D-5 ³ ³ ³ ³ D-5 ³ H-3, fish ³ 1.000E+00 ³ 1.000E+00 ³ BIOFAC( 19,1)

D-5 ³ H-3, crustacea and mollusks ³ 1.000E+00 ³ 1.000E+00 ³ BIOFAC( 19,2)

D-5 ³ ³ ³ ³ D-5 ³ I-129, fish ³ 4.000E+01 ³ 4.000E+01 ³ BIOFAC( 20,1)

D-5 ³ I-129, crustacea and mollusks ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 20,2)

D-5 ³ ³ ³ ³ D-5 ³ Mn-54, fish ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 21,1)

D-5 ³ Mn-54, crustacea and mollusks ³ 9.000E+04 ³ 9.000E+04 ³ BIOFAC( 21,2)

D-5 ³ ³ ³ ³ D-5 ³ Nb-94, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 22,1)

D-5 ³ Nb-94, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 22,2)

D-5 ³ ³ ³ ³ D-5 ³ Nb-95, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 23,1)

D-5 ³ Nb-95, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 23,2)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 11 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Ni-59, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 24,1)

D-5 ³ Ni-59, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 24,2)

D-5 ³ ³ ³ ³ D-5 ³ Ni-63, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 25,1)

D-5 ³ Ni-63, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 25,2)

D-5 ³ ³ ³ ³ D-5 ³ Np-237+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 26,1)

D-5 ³ Np-237+D, crustacea and mollusks ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 26,2)

D-5 ³ ³ ³ ³ D-5 ³ Pa-231, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 27,1)

D-5 ³ Pa-231, crustacea and mollusks ³ 1.100E+02 ³ 1.100E+02 ³ BIOFAC( 27,2)

D-5 ³ ³ ³ ³ D-5 ³ Pb-210+D, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 28,1)

D-5 ³ Pb-210+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 28,2)

D-5 ³ ³ ³ ³ D-5 ³ Po-210, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 29,1)

D-5 ³ Po-210, crustacea and mollusks ³ 2.000E+04 ³ 2.000E+04 ³ BIOFAC( 29,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-238, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 30,1)

D-5 ³ Pu-238, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 30,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-239, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 32,1)

D-5 ³ Pu-239, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 32,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-241, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 33,1)

D-5 ³ Pu-241, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 33,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-241+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 34,1)

D-5 ³ Pu-241+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 34,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-242, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 35,1)

D-5 ³ Pu-242, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 35,2)

D-5 ³ ³ ³ ³ D-5 ³ Ra-226+D, fish ³ 5.000E+01 ³ 5.000E+01 ³ BIOFAC( 38,1)

D-5 ³ Ra-226+D, crustacea and mollusks ³ 2.500E+02 ³ 2.500E+02 ³ BIOFAC( 38,2)

D-5 ³ ³ ³ ³ D-5 ³ Ru-106+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 39,1)

D-5 ³ Ru-106+D, crustacea and mollusks ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 39,2)

D-5 ³ ³ ³ ³ D-5 ³ Sb-124, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 40,1)

D-5 ³ Sb-124, crustacea and mollusks ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 40,2)

D-5 ³ ³ ³ ³ D-5 ³ Sb-125, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 41,1)

D-5 ³ Sb-125, crustacea and mollusks ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 41,2)

D-5 ³ ³ ³ ³ D-5 ³ Sn-113+D, fish ³ 3.000E+03 ³ 3.000E+03 ³ BIOFAC( 43,1)

D-5 ³ Sn-113+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 43,2)

D-5 ³ ³ ³ ³ D-5 ³ Sr-90+D, fish ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 44,1)

D-5 ³ Sr-90+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 44,2)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 12 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Tc-99, fish ³ 2.000E+01 ³ 2.000E+01 ³ BIOFAC( 45,1)

D-5 ³ Tc-99, crustacea and mollusks ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 45,2)

D-5 ³ ³ ³ ³ D-5 ³ Te-125m, fish ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 46,1)

D-5 ³ Te-125m, crustacea and mollusks ³ 7.500E+01 ³ 7.500E+01 ³ BIOFAC( 46,2)

D-5 ³ ³ ³ ³ D-5 ³ Th-229+D, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 47,1)

D-5 ³ Th-229+D, crustacea and mollusks ³ 5.000E+02 ³ 5.000E+02 ³ BIOFAC( 47,2)

D-5 ³ ³ ³ ³ D-5 ³ Th-230, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 48,1)

D-5 ³ Th-230, crustacea and mollusks ³ 5.000E+02 ³ 5.000E+02 ³ BIOFAC( 48,2)

D-5 ³ ³ ³ ³ D-5 ³ U-233, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 49,1)

D-5 ³ U-233, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 49,2)

D-5 ³ ³ ³ ³ D-5 ³ U-234, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 50,1)

D-5 ³ U-234, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 50,2)

D-5 ³ ³ ³ ³ D-5 ³ U-235+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 51,1)

D-5 ³ U-235+D, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 51,2)

D-5 ³ ³ ³ ³ D-5 ³ U-238, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 52,1)

D-5 ³ U-238, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 52,2)

D-5 ³ ³ ³ ³ D-5 ³ U-238+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 53,1)

D-5 ³ U-238+D, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 53,2)

D-5 ³ ³ ³ ³ D-5 ³ Zn-65, fish ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 54,1)

D-5 ³ Zn-65, crustacea and mollusks ³ 1.000E+04 ³ 1.000E+04 ³ BIOFAC( 54,2)

D-5 ³ ³ ³ ³ D-5 ³ Zr-95+D, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 55,1)

D-5 ³ Zr-95+D, crustacea and mollusks ³ 6.700E+00 ³ 6.700E+00 ³ BIOFAC( 55,2)

  1. For DCF1(xxx) only, factors are for infinite depth & area. See ETFG table in Ground Pathway of Detailed Report.
  • Base Case means Default.Lib w/o Associate Nuclide contributions.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 13 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R011 ³ Area of contaminated zone (m**2) ³ 1.000E+04 ³ 1.000E+04 ³ --- ³ AREA R011 ³ Thickness of contaminated zone (m) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ THICK0 R011 ³ Fraction of contamination that is submerged ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ SUBMFRACT R011 ³ Length parallel to aquifer flow (m) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ LCZPAQ R011 ³ Basic radiation dose limit (mrem/yr) ³ 2.500E+01 ³ 3.000E+01 ³ --- ³ BRDL R011 ³ Time since placement of material (yr) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ TI R011 ³ Times for calculations (yr) ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ T( 2)

R011 ³ Times for calculations (yr) ³ 3.000E+00 ³ 3.000E+00 ³ --- ³ T( 3)

R011 ³ Times for calculations (yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ T( 4)

R011 ³ Times for calculations (yr) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ T( 5)

R011 ³ Times for calculations (yr) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ T( 6)

R011 ³ Times for calculations (yr) ³ 3.000E+02 ³ 3.000E+02 ³ --- ³ T( 7)

R011 ³ Times for calculations (yr) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ T( 8)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ --- ³ T( 9)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ --- ³ T(10)

³ ³ ³ ³ ³ R012 ³ Initial principal radionuclide (pCi/g): Ag-110m ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(2)

R012 ³ Initial principal radionuclide (pCi/g): Am-241 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(3)

R012 ³ Initial principal radionuclide (pCi/g): C-14 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(5)

R012 ³ Initial principal radionuclide (pCi/g): Ce-144 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(6)

R012 ³ Initial principal radionuclide (pCi/g): Cm-242 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(7)

R012 ³ Initial principal radionuclide (pCi/g): Cm-243 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(10)

R012 ³ Initial principal radionuclide (pCi/g): Co-57 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(12)

R012 ³ Initial principal radionuclide (pCi/g): Co-58 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(13)

R012 ³ Initial principal radionuclide (pCi/g): Co-60 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(14)

R012 ³ Initial principal radionuclide (pCi/g): Cs-134 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(15)

R012 ³ Initial principal radionuclide (pCi/g): Cs-137 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(16)

R012 ³ Initial principal radionuclide (pCi/g): Eu-154 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(17)

R012 ³ Initial principal radionuclide (pCi/g): Fe-55 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(18)

R012 ³ Initial principal radionuclide (pCi/g): H-3 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(19)

R012 ³ Initial principal radionuclide (pCi/g): I-129 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(20)

R012 ³ Initial principal radionuclide (pCi/g): Mn-54 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(21)

R012 ³ Initial principal radionuclide (pCi/g): Nb-94 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(22)

R012 ³ Initial principal radionuclide (pCi/g): Ni-59 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(24)

R012 ³ Initial principal radionuclide (pCi/g): Ni-63 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(25)

R012 ³ Initial principal radionuclide (pCi/g): Np-237 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(26)

R012 ³ Initial principal radionuclide (pCi/g): Pu-238 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(30)

R012 ³ Initial principal radionuclide (pCi/g): Pu-239 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(32)

R012 ³ Initial principal radionuclide (pCi/g): Pu-241 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(33)

R012 ³ Initial principal radionuclide (pCi/g): Pu-242 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(35)

R012 ³ Initial principal radionuclide (pCi/g): Ru-106 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(39)

R012 ³ Initial principal radionuclide (pCi/g): Sb-124 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(40)

R012 ³ Initial principal radionuclide (pCi/g): Sb-125 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(41)

R012 ³ Initial principal radionuclide (pCi/g): Sn-113 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(43)

R012 ³ Initial principal radionuclide (pCi/g): Sr-90 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(44)

R012 ³ Initial principal radionuclide (pCi/g): Tc-99 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(45)

R012 ³ Initial principal radionuclide (pCi/g): Zn-65 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(54)

R012 ³ Initial principal radionuclide (pCi/g): Zr-95 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(55)

R012 ³ Concentration in groundwater (pCi/L): Ag-110m ³ not used ³ 0.000E+00 ³ --- ³ W1( 2)

R012 ³ Concentration in groundwater (pCi/L): Am-241 ³ not used ³ 0.000E+00 ³ --- ³ W1( 3)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 14 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R012 ³ Concentration in groundwater (pCi/L): C-14 ³ not used ³ 0.000E+00 ³ --- ³ W1( 5)

R012 ³ Concentration in groundwater (pCi/L): Ce-144 ³ not used ³ 0.000E+00 ³ --- ³ W1( 6)

R012 ³ Concentration in groundwater (pCi/L): Cm-242 ³ not used ³ 0.000E+00 ³ --- ³ W1( 7)

R012 ³ Concentration in groundwater (pCi/L): Cm-243 ³ not used ³ 0.000E+00 ³ --- ³ W1(10)

R012 ³ Concentration in groundwater (pCi/L): Co-57 ³ not used ³ 0.000E+00 ³ --- ³ W1(12)

R012 ³ Concentration in groundwater (pCi/L): Co-58 ³ not used ³ 0.000E+00 ³ --- ³ W1(13)

R012 ³ Concentration in groundwater (pCi/L): Co-60 ³ not used ³ 0.000E+00 ³ --- ³ W1(14)

R012 ³ Concentration in groundwater (pCi/L): Cs-134 ³ not used ³ 0.000E+00 ³ --- ³ W1(15)

R012 ³ Concentration in groundwater (pCi/L): Cs-137 ³ not used ³ 0.000E+00 ³ --- ³ W1(16)

R012 ³ Concentration in groundwater (pCi/L): Eu-154 ³ not used ³ 0.000E+00 ³ --- ³ W1(17)

R012 ³ Concentration in groundwater (pCi/L): Fe-55 ³ not used ³ 0.000E+00 ³ --- ³ W1(18)

R012 ³ Concentration in groundwater (pCi/L): H-3 ³ not used ³ 0.000E+00 ³ --- ³ W1(19)

R012 ³ Concentration in groundwater (pCi/L): I-129 ³ not used ³ 0.000E+00 ³ --- ³ W1(20)

R012 ³ Concentration in groundwater (pCi/L): Mn-54 ³ not used ³ 0.000E+00 ³ --- ³ W1(21)

R012 ³ Concentration in groundwater (pCi/L): Nb-94 ³ not used ³ 0.000E+00 ³ --- ³ W1(22)

R012 ³ Concentration in groundwater (pCi/L): Ni-59 ³ not used ³ 0.000E+00 ³ --- ³ W1(24)

R012 ³ Concentration in groundwater (pCi/L): Ni-63 ³ not used ³ 0.000E+00 ³ --- ³ W1(25)

R012 ³ Concentration in groundwater (pCi/L): Np-237 ³ not used ³ 0.000E+00 ³ --- ³ W1(26)

R012 ³ Concentration in groundwater (pCi/L): Pu-238 ³ not used ³ 0.000E+00 ³ --- ³ W1(30)

R012 ³ Concentration in groundwater (pCi/L): Pu-239 ³ not used ³ 0.000E+00 ³ --- ³ W1(32)

R012 ³ Concentration in groundwater (pCi/L): Pu-241 ³ not used ³ 0.000E+00 ³ --- ³ W1(33)

R012 ³ Concentration in groundwater (pCi/L): Pu-242 ³ not used ³ 0.000E+00 ³ --- ³ W1(35)

R012 ³ Concentration in groundwater (pCi/L): Ru-106 ³ not used ³ 0.000E+00 ³ --- ³ W1(39)

R012 ³ Concentration in groundwater (pCi/L): Sb-124 ³ not used ³ 0.000E+00 ³ --- ³ W1(40)

R012 ³ Concentration in groundwater (pCi/L): Sb-125 ³ not used ³ 0.000E+00 ³ --- ³ W1(41)

R012 ³ Concentration in groundwater (pCi/L): Sn-113 ³ not used ³ 0.000E+00 ³ --- ³ W1(43)

R012 ³ Concentration in groundwater (pCi/L): Sr-90 ³ not used ³ 0.000E+00 ³ --- ³ W1(44)

R012 ³ Concentration in groundwater (pCi/L): Tc-99 ³ not used ³ 0.000E+00 ³ --- ³ W1(45)

R012 ³ Concentration in groundwater (pCi/L): Zn-65 ³ not used ³ 0.000E+00 ³ --- ³ W1(54)

R012 ³ Concentration in groundwater (pCi/L): Zr-95 ³ not used ³ 0.000E+00 ³ --- ³ W1(55)

³ ³ ³ ³ ³ R013 ³ Cover depth (m) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ COVER0 R013 ³ Density of cover material (g/cm**3) ³ not used ³ 1.500E+00 ³ --- ³ DENSCV R013 ³ Cover depth erosion rate (m/yr) ³ not used ³ 1.000E-03 ³ --- ³ VCV R013 ³ Density of contaminated zone (g/cm**3) ³ 1.440E+00 ³ 1.500E+00 ³ --- ³ DENSCZ R013 ³ Contaminated zone erosion rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ --- ³ VCZ R013 ³ Contaminated zone total porosity ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ TPCZ R013 ³ Contaminated zone field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCCZ R013 ³ Contaminated zone hydraulic conductivity (m/yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ HCCZ R013 ³ Contaminated zone b parameter ³ 4.380E+00 ³ 5.300E+00 ³ --- ³ BCZ R013 ³ Average annual wind speed (m/sec) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ WIND R013 ³ Humidity in air (g/m**3) ³ 8.000E+00 ³ 8.000E+00 ³ --- ³ HUMID R013 ³ Evapotranspiration coefficient ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ EVAPTR R013 ³ Precipitation (m/yr) ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ PRECIP R013 ³ Irrigation (m/yr) ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ RI R013 ³ Irrigation mode ³ overhead ³ overhead ³ --- ³ IDITCH R013 ³ Runoff coefficient ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ RUNOFF R013 ³ Watershed area for nearby stream or pond (m**2) ³ 1.000E+06 ³ 1.000E+06 ³ --- ³ WAREA R013 ³ Accuracy for water/soil computations ³ 1.000E-03 ³ 1.000E-03 ³ --- ³ EPS

³ ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 15 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R014 ³ Density of saturated zone (g/cm**3) ³ 1.500E+00 ³ 1.500E+00 ³ --- ³ DENSAQ R014 ³ Saturated zone total porosity ³ 3.400E-01 ³ 4.000E-01 ³ --- ³ TPSZ R014 ³ Saturated zone effective porosity ³ 2.700E-01 ³ 2.000E-01 ³ --- ³ EPSZ R014 ³ Saturated zone field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCSZ R014 ³ Saturated zone hydraulic conductivity (m/yr) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ HCSZ R014 ³ Saturated zone hydraulic gradient ³ 2.000E-02 ³ 2.000E-02 ³ --- ³ HGWT R014 ³ Saturated zone b parameter ³ 4.050E+00 ³ 5.300E+00 ³ --- ³ BSZ R014 ³ Water table drop rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ --- ³ VWT R014 ³ Well pump intake depth (m below water table) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DWIBWT R014 ³ Model: Nondispersion (ND) or Mass-Balance (MB) ³ ND ³ ND ³ --- ³ MODEL R014 ³ Well pumping rate (m**3/yr) ³ 2.500E+02 ³ 2.500E+02 ³ --- ³ UW

³ ³ ³ ³ ³ R015 ³ Number of unsaturated zone strata ³ not used ³ 1 ³ --- ³ NS R015 ³ Unsat. zone 1, thickness (m) ³ 1.700E+00 ³ 4.000E+00 ³ --- ³ H(1)

R015 ³ Unsat. zone 1, soil density (g/cm**3) ³ 1.440E+00 ³ 1.500E+00 ³ --- ³ DENSUZ(1)

R015 ³ Unsat. zone 1, total porosity ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ TPUZ(1)

R015 ³ Unsat. zone 1, effective porosity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ EPUZ(1)

R015 ³ Unsat. zone 1, field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCUZ(1)

R015 ³ Unsat. zone 1, soil-specific b parameter ³ 4.380E+00 ³ 5.300E+00 ³ --- ³ BUZ(1)

R015 ³ Unsat. zone 1, hydraulic conductivity (m/yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ HCUZ(1)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ag-110m ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC( 2)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU( 2,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS( 2)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH( 2)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 2)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Am-241 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 3)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 3,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 3)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 3)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 3)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for C-14 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC( 5)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU( 5,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS( 5)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH( 5)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 5)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ce-144 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC( 6)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU( 6,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS( 6)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH( 6)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 6)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 16 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Cm-242 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCC( 7)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCU( 7,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCS( 7)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.260E-04 ³ ALEACH( 7)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 7)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cm-243 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCC(10)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCU(10,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCS(10)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.260E-04 ³ ALEACH(10)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(10)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-57 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(12)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(12,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(12)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(12)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(12)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-58 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(13)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(13,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(13)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(13)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(13)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-60 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(14)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(14,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(14)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(14)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(14)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cs-134 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCC(15)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCU(15,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCS(15)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.774E-05 ³ ALEACH(15)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(15)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cs-137 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCC(16)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCU(16,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCS(16)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.774E-05 ³ ALEACH(16)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(16)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 17 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Eu-154 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCC(17)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCU(17,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCS(17)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.104E-04 ³ ALEACH(17)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(17)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Fe-55 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(18)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(18,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(18)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(18)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(18)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for H-3 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(19)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(19,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(19)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(19)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(19)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for I-129 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCC(20)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCU(20,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCS(20)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 5.506E-01 ³ ALEACH(20)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(20)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Mn-54 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCC(21)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCU(21,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCS(21)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.671E-04 ³ ALEACH(21)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(21)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Nb-94 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(22)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(22,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(22)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(22)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(22)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ni-59 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(24)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(24,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(24)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(24)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(24)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 18 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Ni-63 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(25)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(25,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(25)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(25)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(25)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Np-237 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCC(26)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCU(26,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCS(26)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 6.739E-04 ³ ALEACH(26)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(26)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-238 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(30)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(30,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(30)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(30)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(30)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-239 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(32)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(32,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(32)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(32)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(32)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-241 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(33)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(33,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(33)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(33)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(33)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-242 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(35)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(35,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(35)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(35)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(35)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ru-106 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(39)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(39,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(39)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(39)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(39)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 19 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Sb-124 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(40)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(40,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(40)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(40)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(40)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sb-125 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(41)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(41,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(41)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(41)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(41)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sn-113 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(43)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(43,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(43)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(43)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(43)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sr-90 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCC(44)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCU(44,1)

R016 ³ Saturated zone (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCS(44)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 5.746E-03 ³ ALEACH(44)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(44)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Tc-99 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(45)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(45,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(45)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(45)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(45)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Zn-65 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(54)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(54,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(54)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(54)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(54)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Zr-95 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCC(55)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCU(55,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCS(55)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 7.891E-05 ³ ALEACH(55)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(55)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 20 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for daughter Ac-227 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 1)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 1,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 1)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 1)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 1)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Am-243 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 4)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 4,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 4)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 4)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 4)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Nb-95 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(23)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(23,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(23)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(23)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(23)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Pa-231 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(27)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(27,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(27)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(27)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(27)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Pb-210 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCC(28)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCU(28,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCS(28)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.732E-03 ³ ALEACH(28)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(28)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Po-210 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCC(29)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCU(29,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCS(29)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.700E-02 ³ ALEACH(29)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(29)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Ra-226 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCC(38)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCU(38,1)

R016 ³ Saturated zone (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCS(38)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.473E-03 ³ ALEACH(38)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(38)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 21 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for daughter Te-125m ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(46)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(46,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(46)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(46)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(46)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Th-229 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCC(47)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCU(47,1)

R016 ³ Saturated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCS(47)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.894E-06 ³ ALEACH(47)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(47)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Th-230 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCC(48)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCU(48,1)

R016 ³ Saturated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCS(48)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.894E-06 ³ ALEACH(48)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(48)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-233 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(49)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(49,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(49)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(49)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(49)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-234 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(50)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(50,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(50)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(50)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(50)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-235 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(51)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(51,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(51)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(51)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(51)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-238 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(52)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(52,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(52)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(52)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(52)

R017 ³ Inhalation rate (m**3/yr) ³ 1.140E+04 ³ 8.400E+03 ³ --- ³ INHALR R017 ³ Mass loading for inhalation (g/m**3) ³ 1.000E-04 ³ 1.000E-04 ³ --- ³ MLINH R017 ³ Exposure duration ³ 2.500E+01 ³ 3.000E+01 ³ --- ³ ED R017 ³ Shielding factor, inhalation ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ SHF3

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 22 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R017 ³ Shielding factor, external gamma ³ 7.000E-01 ³ 7.000E-01 ³ --- ³ SHF1 R017 ³ Fraction of time spent indoors ³ 1.700E-01 ³ 5.000E-01 ³ --- ³ FIND R017 ³ Fraction of time spent outdoors (on site) ³ 6.000E-02 ³ 2.500E-01 ³ --- ³ FOTD R017 ³ Shape factor flag, external gamma ³ 1.000E+00 ³ 1.000E+00 ³ >0 shows circular AREA. ³ FS R017 ³ Radii of shape factor array (used if FS = -1): ³ ³ ³ ³ R017 ³ Outer annular radius (m), ring 1: ³ not used ³ 5.000E+01 ³ --- ³ RAD_SHAPE( 1)

R017 ³ Outer annular radius (m), ring 2: ³ not used ³ 7.071E+01 ³ --- ³ RAD_SHAPE( 2)

R017 ³ Outer annular radius (m), ring 3: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 3)

R017 ³ Outer annular radius (m), ring 4: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 4)

R017 ³ Outer annular radius (m), ring 5: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 5)

R017 ³ Outer annular radius (m), ring 6: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 6)

R017 ³ Outer annular radius (m), ring 7: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 7)

R017 ³ Outer annular radius (m), ring 8: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 8)

R017 ³ Outer annular radius (m), ring 9: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 9)

R017 ³ Outer annular radius (m), ring 10: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(10)

R017 ³ Outer annular radius (m), ring 11: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(11)

R017 ³ Outer annular radius (m), ring 12: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(12)

³ ³ ³ ³ ³ R017 ³ Fractions of annular areas within AREA: ³ ³ ³ ³ R017 ³ Ring 1 ³ not used ³ 1.000E+00 ³ --- ³ FRACA( 1)

R017 ³ Ring 2 ³ not used ³ 2.732E-01 ³ --- ³ FRACA( 2)

R017 ³ Ring 3 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 3)

R017 ³ Ring 4 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 4)

R017 ³ Ring 5 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 5)

R017 ³ Ring 6 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 6)

R017 ³ Ring 7 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 7)

R017 ³ Ring 8 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 8)

R017 ³ Ring 9 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 9)

R017 ³ Ring 10 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(10)

R017 ³ Ring 11 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(11)

R017 ³ Ring 12 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(12)

³ ³ ³ ³ ³ R018 ³ Fruits, vegetables and grain consumption (kg/yr) ³ not used ³ 1.600E+02 ³ --- ³ DIET(1)

R018 ³ Leafy vegetable consumption (kg/yr) ³ not used ³ 1.400E+01 ³ --- ³ DIET(2)

R018 ³ Milk consumption (L/yr) ³ not used ³ 9.200E+01 ³ --- ³ DIET(3)

R018 ³ Meat and poultry consumption (kg/yr) ³ not used ³ 6.300E+01 ³ --- ³ DIET(4)

R018 ³ Fish consumption (kg/yr) ³ not used ³ 5.400E+00 ³ --- ³ DIET(5)

R018 ³ Other seafood consumption (kg/yr) ³ not used ³ 9.000E-01 ³ --- ³ DIET(6)

R018 ³ Soil ingestion rate (g/yr) ³ 3.650E+01 ³ 3.650E+01 ³ --- ³ SOIL R018 ³ Drinking water intake (L/yr) ³ not used ³ 5.100E+02 ³ --- ³ DWI R018 ³ Contamination fraction of drinking water ³ not used ³ 1.000E+00 ³ --- ³ FDW R018 ³ Contamination fraction of household water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FHHW R018 ³ Contamination fraction of livestock water ³ not used ³ 1.000E+00 ³ --- ³ FLW R018 ³ Contamination fraction of irrigation water ³ not used ³ 1.000E+00 ³ --- ³ FIRW R018 ³ Contamination fraction of aquatic food ³ not used ³ 5.000E-01 ³ --- ³ FR9 R018 ³ Contamination fraction of plant food ³ not used ³-1 ³ --- ³ FPLANT R018 ³ Contamination fraction of meat ³ not used ³-1 ³ --- ³ FMEAT R018 ³ Contamination fraction of milk ³ not used ³-1 ³ --- ³ FMILK

³ ³ ³ ³ ³ R019 ³ Livestock fodder intake for meat (kg/day) ³ not used ³ 6.800E+01 ³ --- ³ LFI5

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 23 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R019 ³ Livestock fodder intake for milk (kg/day) ³ not used ³ 5.500E+01 ³ --- ³ LFI6 R019 ³ Livestock water intake for meat (L/day) ³ not used ³ 5.000E+01 ³ --- ³ LWI5 R019 ³ Livestock water intake for milk (L/day) ³ not used ³ 1.600E+02 ³ --- ³ LWI6 R019 ³ Livestock soil intake (kg/day) ³ not used ³ 5.000E-01 ³ --- ³ LSI R019 ³ Mass loading for foliar deposition (g/m**3) ³ not used ³ 1.000E-04 ³ --- ³ MLFD R019 ³ Depth of soil mixing layer (m) ³ 1.500E-01 ³ 1.500E-01 ³ --- ³ DM R019 ³ Depth of roots (m) ³ not used ³ 9.000E-01 ³ --- ³ DROOT R019 ³ Drinking water fraction from ground water ³ not used ³ 1.000E+00 ³ --- ³ FGWDW R019 ³ Household water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWHH R019 ³ Livestock water fraction from ground water ³ not used ³ 1.000E+00 ³ --- ³ FGWLW R019 ³ Irrigation fraction from ground water ³ not used ³ 1.000E+00 ³ --- ³ FGWIR

³ ³ ³ ³ ³ R19B ³ Wet weight crop yield for Non-Leafy (kg/m**2) ³ not used ³ 7.000E-01 ³ --- ³ YV(1)

R19B ³ Wet weight crop yield for Leafy (kg/m**2) ³ not used ³ 1.500E+00 ³ --- ³ YV(2)

R19B ³ Wet weight crop yield for Fodder (kg/m**2) ³ not used ³ 1.100E+00 ³ --- ³ YV(3)

R19B ³ Growing Season for Non-Leafy (years) ³ not used ³ 1.700E-01 ³ --- ³ TE(1)

R19B ³ Growing Season for Leafy (years) ³ not used ³ 2.500E-01 ³ --- ³ TE(2)

R19B ³ Growing Season for Fodder (years) ³ not used ³ 8.000E-02 ³ --- ³ TE(3)

R19B ³ Translocation Factor for Non-Leafy ³ not used ³ 1.000E-01 ³ --- ³ TIV(1)

R19B ³ Translocation Factor for Leafy ³ not used ³ 1.000E+00 ³ --- ³ TIV(2)

R19B ³ Translocation Factor for Fodder ³ not used ³ 1.000E+00 ³ --- ³ TIV(3)

R19B ³ Dry Foliar Interception Fraction for Non-Leafy ³ not used ³ 2.500E-01 ³ --- ³ RDRY(1)

R19B ³ Dry Foliar Interception Fraction for Leafy ³ not used ³ 2.500E-01 ³ --- ³ RDRY(2)

R19B ³ Dry Foliar Interception Fraction for Fodder ³ not used ³ 2.500E-01 ³ --- ³ RDRY(3)

R19B ³ Wet Foliar Interception Fraction for Non-Leafy ³ not used ³ 2.500E-01 ³ --- ³ RWET(1)

R19B ³ Wet Foliar Interception Fraction for Leafy ³ not used ³ 2.500E-01 ³ --- ³ RWET(2)

R19B ³ Wet Foliar Interception Fraction for Fodder ³ not used ³ 2.500E-01 ³ --- ³ RWET(3)

R19B ³ Weathering Removal Constant for Vegetation ³ not used ³ 2.000E+01 ³ --- ³ WLAM

³ ³ ³ ³ ³ C14 ³ C-12 concentration in water (g/cm**3) ³ 2.000E-05 ³ 2.000E-05 ³ --- ³ C12WTR C14 ³ C-12 concentration in contaminated soil (g/g) ³ 3.000E-02 ³ 3.000E-02 ³ --- ³ C12CZ C14 ³ Fraction of vegetation carbon from soil ³ 2.000E-02 ³ 2.000E-02 ³ --- ³ CSOIL C14 ³ Fraction of vegetation carbon from air ³ 9.800E-01 ³ 9.800E-01 ³ --- ³ CAIR C14 ³ C-14 evasion layer thickness in soil (m) ³ 3.000E-01 ³ 3.000E-01 ³ --- ³ DMC C14 ³ C-14 evasion flux rate from soil (1/sec) ³ 7.000E-07 ³ 7.000E-07 ³ --- ³ EVSN C14 ³ C-12 evasion flux rate from soil (1/sec) ³ 1.000E-10 ³ 1.000E-10 ³ --- ³ REVSN C14 ³ Fraction of grain in beef cattle feed ³ 8.000E-01 ³ 8.000E-01 ³ --- ³ AVFG4 C14 ³ Fraction of grain in milk cow feed ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ AVFG5

³ ³ ³ ³ ³ STOR ³ Storage times of contaminated foodstuffs (days): ³ ³ ³ ³ STOR ³ Fruits, non-leafy vegetables, and grain ³ 1.400E+01 ³ 1.400E+01 ³ --- ³ STOR_T(1)

STOR ³ Leafy vegetables ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(2)

STOR ³ Milk ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(3)

STOR ³ Meat and poultry ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ STOR_T(4)

STOR ³ Fish ³ 7.000E+00 ³ 7.000E+00 ³ --- ³ STOR_T(5)

STOR ³ Crustacea and mollusks ³ 7.000E+00 ³ 7.000E+00 ³ --- ³ STOR_T(6)

STOR ³ Well water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(7)

STOR ³ Surface water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(8)

STOR ³ Livestock fodder ³ 4.500E+01 ³ 4.500E+01 ³ --- ³ STOR_T(9)

³ ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 24 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R021 ³ Thickness of building foundation (m) ³ 1.500E-01 ³ 1.500E-01 ³ --- ³ FLOOR1 R021 ³ Bulk density of building foundation (g/cm**3) ³ 2.400E+00 ³ 2.400E+00 ³ --- ³ DENSFL R021 ³ Total porosity of the cover material ³ not used ³ 4.000E-01 ³ --- ³ TPCV R021 ³ Total porosity of the building foundation ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ TPFL R021 ³ Volumetric water content of the cover material ³ not used ³ 5.000E-02 ³ --- ³ PH2OCV R021 ³ Volumetric water content of the foundation ³ 3.000E-02 ³ 3.000E-02 ³ --- ³ PH2OFL R021 ³ Diffusion coefficient for radon gas (m/sec): ³ ³ ³ ³ R021 ³ in cover material ³ not used ³ 2.000E-06 ³ --- ³ DIFCV R021 ³ in foundation material ³ 3.000E-07 ³ 3.000E-07 ³ --- ³ DIFFL R021 ³ in contaminated zone soil ³ 2.000E-06 ³ 2.000E-06 ³ --- ³ DIFCZ R021 ³ Radon vertical dimension of mixing (m) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ HMIX R021 ³ Average building air exchange rate (1/hr) ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ REXG R021 ³ Height of the building (room) (m) ³ 2.500E+00 ³ 2.500E+00 ³ --- ³ HRM R021 ³ Building interior area factor ³ 0.000E+00 ³ 0.000E+00 ³ code computed (time dependent) ³ FAI R021 ³ Building depth below ground surface (m) ³-1.000E+00 ³-1.000E+00 ³ code computed (time dependent) ³ DMFL R021 ³ Emanating power of Rn-222 gas ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ EMANA(1)

R021 ³ Emanating power of Rn-220 gas ³ not used ³ 1.500E-01 ³ --- ³ EMANA(2)

³ ³ ³ ³ ³ TITL ³ Number of graphical time points ³ 32 ³ --- ³ --- ³ NPTS TITL ³ Maximum number of integration points for dose ³ 17 ³ --- ³ --- ³ LYMAX TITL ³ Maximum number of integration points for risk ³ 257 ³ --- ³ --- ³ KYMAX

Summary of Pathway Selections Pathway ³ User Selection

Å 1 -- external gamma ³ active 2 -- inhalation (w/o radon)³ active 3 -- plant ingestion ³ suppressed 4 -- meat ingestion ³ suppressed 5 -- milk ingestion ³ suppressed 6 -- aquatic foods ³ suppressed 7 -- drinking water ³ suppressed 8 -- soil ingestion ³ active 9 -- radon ³ active Find peak pathway doses ³ active

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 25 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 10000.00 square meters Ag-110m 1.000E+00 Thickness: 2.00 meters Am-241 1.000E+00 Cover Depth: 0.00 meters C-14 1.000E+00 Ce-144 1.000E+00 Cm-242 1.000E+00 Cm-243 1.000E+00 Co-57 1.000E+00 Co-58 1.000E+00 Co-60 1.000E+00 Cs-134 1.000E+00 Cs-137 1.000E+00 Eu-154 1.000E+00 Fe-55 1.000E+00 H-3 1.000E+00 I-129 1.000E+00 Mn-54 1.000E+00 Nb-94 1.000E+00 Ni-59 1.000E+00 Ni-63 1.000E+00 Np-237 1.000E+00 Pu-238 1.000E+00 Pu-239 1.000E+00 Pu-241 1.000E+00 Pu-242 1.000E+00 Ru-106 1.000E+00 Sb-124 1.000E+00 Sb-125 1.000E+00 Sn-113 1.000E+00 Sr-90 1.000E+00 Tc-99 1.000E+00 Zn-65 1.000E+00 Zr-95 1.000E+00 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 1.114E+01 6.639E+00 4.424E+00 2.243E+00 8.877E-01 4.018E-01 2.762E-01 1.918E-01 M(t): 4.455E-01 2.655E-01 1.770E-01 8.972E-02 3.551E-02 1.607E-02 1.105E-02 7.673E-03 Maximum TDOSE(t): 1.114E+01 mrem/yr at t = 0.000E+00 years

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 26 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 1.329E+00 0.1194 9.136E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.175E-05 0.0000 Am-241 7.556E-03 0.0007 1.091E-02 0.0010 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.040E-02 0.0027 C-14 5.633E-07 0.0000 5.556E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.185E-06 0.0000 Ce-144 3.628E-02 0.0033 6.117E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.174E-04 0.0000 Cm-242 1.541E-05 0.0000 2.409E-04 0.0000 1.042E-17 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.567E-04 0.0000 Cm-243 9.814E-02 0.0088 7.492E-03 0.0007 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.082E-02 0.0019 Co-57 5.571E-02 0.0050 1.456E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.436E-06 0.0000 Co-58 2.714E-01 0.0244 7.319E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.169E-06 0.0000 Co-60 2.560E+00 0.2299 5.069E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.116E-04 0.0000 Cs-134 1.348E+00 0.1210 9.693E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.226E-04 0.0000 Cs-137 5.651E-01 0.0507 7.790E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.149E-04 0.0000 Eu-154 1.244E+00 0.1117 6.794E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.709E-05 0.0000 Fe-55 0.000E+00 0.0000 5.860E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.494E-06 0.0000 H-3 0.000E+00 0.0000 1.126E-04 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.611E-07 0.0000 I-129 1.770E-03 0.0002 3.305E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.782E-03 0.0002 Mn-54 5.937E-01 0.0533 1.134E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.593E-05 0.0000 Nb-94 1.115E+00 0.1001 7.021E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.115E-05 0.0000 Ni-59 0.000E+00 0.0000 6.670E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.763E-06 0.0000 Ni-63 0.000E+00 0.0000 1.548E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.826E-06 0.0000 Np-237 1.862E-01 0.0167 1.334E-02 0.0012 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.729E-02 0.0033 Pu-238 2.668E-05 0.0000 9.645E-03 0.0009 8.358E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.676E-02 0.0024 Pu-239 5.039E-05 0.0000 1.060E-02 0.0010 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.972E-02 0.0027 Pu-241 9.127E-06 0.0000 2.076E-04 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.846E-04 0.0001 Pu-242 2.251E-05 0.0000 1.015E-02 0.0009 2.596E-25 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.821E-02 0.0025 Ru-106 1.125E-01 0.0101 6.117E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.194E-04 0.0000 Sb-124 3.895E-01 0.0350 1.234E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.681E-05 0.0000 Sb-125 2.538E-01 0.0228 2.046E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.773E-05 0.0000 Sn-113 7.837E-02 0.0070 8.391E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.455E-06 0.0000 Sr-90 4.078E-03 0.0004 3.185E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.264E-03 0.0001 Tc-99 1.476E-05 0.0000 1.411E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.414E-06 0.0000 Zn-65 2.844E-01 0.0255 2.300E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.518E-05 0.0000 Zr-95 3.597E-01 0.0323 1.760E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.260E-05 0.0000 Total 1.089E+01 0.9783 6.282E-02 0.0056 8.368E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.791E-01 0.0161

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 27 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.329E+00 0.1194 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.887E-02 0.0044 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.031E-05 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.640E-02 0.0033 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.131E-04 0.0001 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.265E-01 0.0114 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.571E-02 0.0050 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.714E-01 0.0244 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.560E+00 0.2299 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.348E+00 0.1211 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.655E-01 0.0508 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.244E+00 0.1117 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.552E-06 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.128E-04 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.555E-03 0.0003 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.937E-01 0.0533 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.115E+00 0.1001 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.829E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.981E-06 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.368E-01 0.0213 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.643E-02 0.0033 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.036E-02 0.0036 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.014E-04 0.0001 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.838E-02 0.0034 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.126E-01 0.0101 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.895E-01 0.0350 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.538E-01 0.0228 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.837E-02 0.0070 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.374E-03 0.0005 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.331E-05 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.844E-01 0.0255 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.597E-01 0.0323 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.114E+01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 28 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 2.155E-01 0.0325 1.481E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.769E-06 0.0000 Am-241 7.479E-03 0.0011 1.080E-02 0.0016 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.009E-02 0.0045 C-14 9.088E-09 0.0000 8.964E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.751E-08 0.0000 Ce-144 1.489E-02 0.0022 2.510E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.816E-05 0.0000 Cm-242 3.361E-06 0.0000 8.933E-05 0.0000 2.619E-16 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.242E-04 0.0000 Cm-243 9.577E-02 0.0144 7.312E-03 0.0011 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.031E-02 0.0031 Co-57 2.188E-02 0.0033 5.717E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.527E-06 0.0000 Co-58 7.597E-03 0.0011 2.048E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.286E-07 0.0000 Co-60 2.244E+00 0.3380 4.444E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.855E-04 0.0000 Cs-134 9.630E-01 0.1451 6.925E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.734E-04 0.0001 Cs-137 5.522E-01 0.0832 7.612E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.054E-04 0.0001 Eu-154 1.150E+00 0.1732 6.278E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.123E-05 0.0000 Fe-55 0.000E+00 0.0000 4.533E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.476E-06 0.0000 H-3 0.000E+00 0.0000 2.117E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.911E-08 0.0000 I-129 1.021E-03 0.0002 1.906E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.027E-03 0.0002 Mn-54 2.638E-01 0.0397 5.039E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.080E-06 0.0000 Nb-94 4.978E-01 0.0750 3.135E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.837E-05 0.0000 Ni-59 0.000E+00 0.0000 6.668E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.762E-06 0.0000 Ni-63 0.000E+00 0.0000 1.537E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.790E-06 0.0000 Np-237 1.860E-01 0.0280 1.333E-02 0.0020 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.727E-02 0.0056 Pu-238 2.647E-05 0.0000 9.569E-03 0.0014 1.250E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.654E-02 0.0040 Pu-239 5.039E-05 0.0000 1.060E-02 0.0016 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.971E-02 0.0045 Pu-241 2.047E-05 0.0000 2.148E-04 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.045E-04 0.0001 Pu-242 2.251E-05 0.0000 1.015E-02 0.0015 8.034E-24 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.820E-02 0.0042 Ru-106 2.526E-02 0.0038 1.373E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.681E-05 0.0000 Sb-124 2.593E-03 0.0004 8.216E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.119E-07 0.0000 Sb-125 8.828E-02 0.0133 7.400E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.655E-06 0.0000 Sn-113 3.879E-03 0.0006 4.153E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.185E-07 0.0000 Sr-90 3.960E-03 0.0006 3.092E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.227E-03 0.0002 Tc-99 6.589E-06 0.0000 6.300E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.757E-06 0.0000 Zn-65 4.497E-02 0.0068 3.638E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.726E-06 0.0000 Zr-95 1.015E-02 0.0015 3.963E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.308E-07 0.0000 Total 6.400E+00 0.9641 6.214E-02 0.0094 1.252E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.764E-01 0.0266

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 29 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.155E-01 0.0325 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.838E-02 0.0073 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.730E-07 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.494E-02 0.0023 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.169E-04 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.234E-01 0.0186 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.188E-02 0.0033 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.597E-03 0.0011 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.244E+00 0.3381 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.633E-01 0.1451 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.526E-01 0.0832 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.150E+00 0.1732 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.521E-06 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.122E-05 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.050E-03 0.0003 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.638E-01 0.0397 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.978E-01 0.0750 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.829E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.944E-06 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.366E-01 0.0356 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.614E-02 0.0054 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.036E-02 0.0061 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.398E-04 0.0001 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.838E-02 0.0058 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.529E-02 0.0038 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.593E-03 0.0004 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.829E-02 0.0133 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.879E-03 0.0006 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.218E-03 0.0008 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.041E-05 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.498E-02 0.0068 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.015E-02 0.0015 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.639E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 30 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 5.664E-03 0.0013 3.893E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.779E-07 0.0000 Am-241 7.329E-03 0.0017 1.058E-02 0.0024 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.949E-02 0.0067 C-14 2.342E-12 0.0000 2.310E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.740E-11 0.0000 Ce-144 2.507E-03 0.0006 4.228E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.111E-06 0.0000 Cm-242 2.768E-07 0.0000 4.989E-05 0.0000 4.555E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.373E-04 0.0000 Cm-243 9.120E-02 0.0206 6.963E-03 0.0016 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.935E-02 0.0044 Co-57 3.373E-03 0.0008 8.816E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.897E-07 0.0000 Co-58 5.950E-06 0.0000 1.604E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.791E-10 0.0000 Co-60 1.724E+00 0.3898 3.415E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.425E-04 0.0000 Cs-134 4.916E-01 0.1111 3.535E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.906E-04 0.0000 Cs-137 5.272E-01 0.1192 7.268E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.871E-04 0.0001 Eu-154 9.818E-01 0.2219 5.360E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.083E-05 0.0000 Fe-55 0.000E+00 0.0000 2.712E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.079E-06 0.0000 H-3 0.000E+00 0.0000 7.472E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.733E-09 0.0000 I-129 3.393E-04 0.0001 6.337E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.416E-04 0.0001 Mn-54 5.211E-02 0.0118 9.952E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.398E-06 0.0000 Nb-94 9.923E-02 0.0224 6.249E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.662E-06 0.0000 Ni-59 0.000E+00 0.0000 6.666E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.762E-06 0.0000 Ni-63 0.000E+00 0.0000 1.514E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.720E-06 0.0000 Np-237 1.858E-01 0.0420 1.331E-02 0.0030 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.722E-02 0.0084 Pu-238 2.605E-05 0.0000 9.417E-03 0.0021 1.448E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.612E-02 0.0059 Pu-239 5.038E-05 0.0000 1.059E-02 0.0024 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.971E-02 0.0067 Pu-241 4.122E-05 0.0000 2.278E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.400E-04 0.0001 Pu-242 2.250E-05 0.0000 1.015E-02 0.0023 2.016E-22 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.820E-02 0.0064 Ru-106 1.273E-03 0.0003 6.921E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.351E-06 0.0000 Sb-124 1.150E-07 0.0000 3.643E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.962E-12 0.0000 Sb-125 1.067E-02 0.0024 8.949E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.053E-07 0.0000 Sn-113 9.501E-06 0.0000 1.017E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.025E-09 0.0000 Sr-90 3.732E-03 0.0008 2.915E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.157E-03 0.0003 Tc-99 1.314E-06 0.0000 1.256E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.489E-07 0.0000 Zn-65 1.124E-03 0.0003 9.096E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.182E-07 0.0000 Zr-95 3.732E-06 0.0000 1.453E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.215E-10 0.0000 Total 4.190E+00 0.9470 6.134E-02 0.0139 1.453E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.732E-01 0.0391

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 31 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.664E-03 0.0013 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.740E-02 0.0107 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.508E-10 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.516E-03 0.0006 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.875E-04 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.175E-01 0.0266 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.374E-03 0.0008 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.950E-06 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.725E+00 0.3898 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.918E-01 0.1112 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.276E-01 0.1193 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.819E-01 0.2219 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.106E-06 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.489E-07 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.815E-04 0.0002 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.211E-02 0.0118 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.924E-02 0.0224 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.828E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.872E-06 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.363E-01 0.0534 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.557E-02 0.0080 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.035E-02 0.0091 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.089E-04 0.0002 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.837E-02 0.0087 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.274E-03 0.0003 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.150E-07 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.067E-02 0.0024 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.502E-06 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.918E-03 0.0011 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.075E-06 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.125E-03 0.0003 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.732E-06 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.424E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 32 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 1.667E-08 0.0000 1.146E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.237E-13 0.0000 Am-241 6.824E-03 0.0030 9.856E-03 0.0044 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.746E-02 0.0122 C-14 5.792E-25 0.0000 5.713E-23 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.303E-24 0.0000 Ce-144 4.915E-06 0.0000 8.286E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.590E-08 0.0000 Cm-242 1.258E-07 0.0000 4.547E-05 0.0000 1.597E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.261E-04 0.0001 Cm-243 7.686E-02 0.0343 5.870E-03 0.0026 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.631E-02 0.0073 Co-57 4.857E-06 0.0000 1.269E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.612E-10 0.0000 Co-58 8.000E-17 0.0000 2.157E-23 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.408E-21 0.0000 Co-60 6.860E-01 0.3059 1.359E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.671E-05 0.0000 Cs-134 4.673E-02 0.0208 3.360E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.812E-05 0.0000 Cs-137 4.484E-01 0.1999 6.181E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.292E-04 0.0001 Eu-154 5.649E-01 0.2518 3.084E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.499E-05 0.0000 Fe-55 0.000E+00 0.0000 4.490E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.443E-07 0.0000 H-3 0.000E+00 0.0000 6.012E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.395E-14 0.0000 I-129 7.190E-06 0.0000 1.343E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.238E-06 0.0000 Mn-54 1.784E-04 0.0001 3.407E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.787E-09 0.0000 Nb-94 3.510E-04 0.0002 2.210E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.295E-08 0.0000 Ni-59 0.000E+00 0.0000 6.657E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.760E-06 0.0000 Ni-63 0.000E+00 0.0000 1.438E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.482E-06 0.0000 Np-237 1.849E-01 0.0824 1.325E-02 0.0059 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.704E-02 0.0165 Pu-238 2.464E-05 0.0000 8.905E-03 0.0040 3.746E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.470E-02 0.0110 Pu-239 5.034E-05 0.0000 1.059E-02 0.0047 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.968E-02 0.0132 Pu-241 9.667E-05 0.0000 2.596E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.272E-04 0.0003 Pu-242 2.249E-05 0.0000 1.014E-02 0.0045 1.555E-20 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.818E-02 0.0126 Ru-106 3.658E-08 0.0000 1.989E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.882E-11 0.0000 Sb-124 6.673E-23 0.0000 2.114E-29 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.880E-27 0.0000 Sb-125 6.548E-06 0.0000 5.492E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.942E-10 0.0000 Sn-113 6.912E-15 0.0000 7.401E-21 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.458E-19 0.0000 Sr-90 3.035E-03 0.0014 2.370E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.406E-04 0.0004 Tc-99 4.647E-09 0.0000 4.443E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.649E-09 0.0000 Zn-65 2.780E-09 0.0000 2.249E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.394E-13 0.0000 Zr-95 3.483E-18 0.0000 1.356E-24 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.134E-22 0.0000 Total 2.018E+00 0.8999 5.894E-02 0.0263 3.762E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.656E-01 0.0738

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 33 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.667E-08 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.414E-02 0.0197 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.201E-23 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.931E-06 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.717E-04 0.0001 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.904E-02 0.0442 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.858E-06 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.000E-17 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.861E-01 0.3059 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.674E-02 0.0208 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.487E-01 0.2000 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.649E-01 0.2519 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.488E-07 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.026E-12 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.444E-05 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.784E-04 0.0001 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.510E-04 0.0002 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.826E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.626E-06 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.352E-01 0.1049 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.363E-02 0.0150 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.032E-02 0.0180 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.084E-03 0.0005 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.835E-02 0.0171 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.662E-08 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.674E-23 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.549E-06 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.913E-15 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.999E-03 0.0018 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.341E-09 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.780E-09 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.484E-18 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.243E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 34 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 2.622E-24 0.0000 1.802E-30 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.237E-29 0.0000 Am-241 5.567E-03 0.0063 8.038E-03 0.0091 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.239E-02 0.0252 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 9.018E-14 0.0000 1.520E-17 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.917E-16 0.0000 Cm-242 1.072E-07 0.0000 3.876E-05 0.0000 4.079E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.075E-04 0.0001 Cm-243 4.714E-02 0.0531 3.605E-03 0.0041 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.002E-02 0.0113 Co-57 3.693E-14 0.0000 9.652E-20 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.267E-18 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 4.928E-02 0.0555 9.758E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.073E-06 0.0000 Cs-134 5.616E-05 0.0001 4.039E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.178E-08 0.0000 Cs-137 2.822E-01 0.3179 3.891E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.072E-04 0.0002 Eu-154 1.164E-01 0.1311 6.355E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.211E-06 0.0000 Fe-55 0.000E+00 0.0000 2.636E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.021E-09 0.0000 H-3 0.000E+00 0.0000 1.339E-26 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.107E-29 0.0000 I-129 1.186E-10 0.0000 2.216E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.194E-10 0.0000 Mn-54 1.610E-11 0.0000 3.076E-18 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.321E-16 0.0000 Nb-94 3.478E-11 0.0000 2.190E-16 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.283E-15 0.0000 Ni-59 0.000E+00 0.0000 6.633E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.753E-06 0.0000 Ni-63 0.000E+00 0.0000 1.240E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.866E-06 0.0000 Np-237 1.824E-01 0.2055 1.307E-02 0.0147 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.655E-02 0.0412 Pu-238 2.100E-05 0.0000 7.591E-03 0.0086 8.530E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.106E-02 0.0237 Pu-239 5.022E-05 0.0001 1.056E-02 0.0119 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.961E-02 0.0334 Pu-241 1.619E-04 0.0002 2.795E-04 0.0003 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.802E-04 0.0009 Pu-242 2.245E-05 0.0000 1.013E-02 0.0114 1.059E-18 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.813E-02 0.0317 Ru-106 3.866E-21 0.0000 2.101E-25 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.102E-24 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 4.355E-15 0.0000 3.652E-21 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.287E-19 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 1.681E-03 0.0019 1.313E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.209E-04 0.0006 Tc-99 4.607E-16 0.0000 4.405E-18 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.627E-16 0.0000 Zn-65 2.656E-25 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.154E-29 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 6.850E-01 0.7717 5.332E-02 0.0601 8.571E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.494E-01 0.1683

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 35 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.622E-24 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.600E-02 0.0406 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.049E-14 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.464E-04 0.0002 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.076E-02 0.0684 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.694E-14 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.928E-02 0.0555 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.618E-05 0.0001 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.824E-01 0.3182 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.164E-01 0.1311 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.047E-09 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.342E-26 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.383E-10 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.610E-11 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.478E-11 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.819E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.990E-06 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.320E-01 0.2614 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.867E-02 0.0323 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.022E-02 0.0453 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.222E-03 0.0014 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.828E-02 0.0431 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.870E-21 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.355E-15 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.215E-03 0.0025 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.278E-16 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.657E-25 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.877E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 36 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 2.730E-03 0.0068 3.939E-03 0.0098 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.097E-02 0.0273 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 6.136E-08 0.0000 2.216E-05 0.0001 1.191E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.147E-05 0.0002 Cm-243 8.515E-03 0.0212 6.613E-04 0.0016 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.838E-03 0.0046 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 4.893E-06 0.0000 9.690E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.045E-10 0.0000 Cs-134 3.381E-15 0.0000 2.432E-21 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.311E-18 0.0000 Cs-137 5.585E-02 0.1390 7.700E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.101E-05 0.0001 Eu-154 4.624E-04 0.0012 2.524E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.865E-08 0.0000 Fe-55 0.000E+00 0.0000 4.084E-19 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.132E-17 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 2.166E-27 0.0000 4.044E-30 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.180E-27 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 6.549E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.731E-06 0.0000 Ni-63 0.000E+00 0.0000 7.391E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.304E-06 0.0000 Np-237 1.740E-01 0.4331 1.247E-02 0.0310 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.486E-02 0.0868 Pu-238 1.202E-05 0.0000 4.340E-03 0.0108 2.386E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.204E-02 0.0300 Pu-239 4.982E-05 0.0001 1.048E-02 0.0261 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.938E-02 0.0731 Pu-241 1.126E-04 0.0003 1.641E-04 0.0004 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.571E-04 0.0011 Pu-242 2.231E-05 0.0001 1.006E-02 0.0250 1.086E-16 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.796E-02 0.0696 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 2.124E-04 0.0005 1.659E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.583E-05 0.0002 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 2.420E-01 0.6023 4.214E-02 0.1049 2.398E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.177E-01 0.2929

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 37 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.764E-02 0.0439 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.369E-05 0.0002 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.101E-02 0.0274 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.894E-06 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.382E-15 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.590E-02 0.1391 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.624E-04 0.0012 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.173E-17 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.350E-27 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.796E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.378E-06 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.213E-01 0.5509 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.639E-02 0.0408 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.990E-02 0.0993 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.337E-04 0.0018 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.804E-02 0.0947 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.799E-04 0.0007 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.018E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 38 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 3.600E-04 0.0013 5.133E-04 0.0019 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.430E-03 0.0052 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 1.264E-08 0.0000 4.488E-06 0.0000 1.666E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.244E-05 0.0000 Cm-243 6.430E-05 0.0002 1.698E-05 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.750E-05 0.0002 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 1.788E-17 0.0000 3.541E-23 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.478E-21 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 5.457E-04 0.0020 7.522E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.006E-07 0.0000 Eu-154 6.385E-11 0.0000 3.486E-16 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.955E-15 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 6.314E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.669E-06 0.0000 Ni-63 0.000E+00 0.0000 1.685E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.251E-07 0.0000 Np-237 1.521E-01 0.5506 1.090E-02 0.0395 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.047E-02 0.1103 Pu-238 2.476E-06 0.0000 8.790E-04 0.0032 3.295E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.437E-03 0.0088 Pu-239 4.870E-05 0.0002 1.024E-02 0.0371 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.870E-02 0.1039 Pu-241 1.514E-05 0.0001 2.164E-05 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.029E-05 0.0002 Pu-242 2.192E-05 0.0001 9.887E-03 0.0358 5.912E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.747E-02 0.0994 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 5.762E-07 0.0000 4.500E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.786E-07 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 1.531E-01 0.5544 3.246E-02 0.1175 3.312E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.063E-02 0.3281

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 39 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.303E-03 0.0083 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 1.165E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.695E-05 0.0001 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.288E-04 0.0005 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.788E-17 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.461E-04 0.0020 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.385E-11 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.732E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.420E-07 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.934E-01 0.7003 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 2.329E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.319E-03 0.0120 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.899E-02 0.1412 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.707E-05 0.0004 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 2.859E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.737E-02 0.1353 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.593E-07 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 2.341E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.762E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 40 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 3.512E-06 0.0000 6.404E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.786E-06 0.0000 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 1.042E-09 0.0000 1.710E-08 0.0000 9.024E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.673E-08 0.0000 Cm-243 5.343E-08 0.0000 1.115E-05 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.126E-05 0.0002 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 5.028E-11 0.0000 6.931E-17 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.692E-14 0.0000 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 5.555E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.468E-06 0.0000 Ni-63 0.000E+00 0.0000 9.521E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.968E-09 0.0000 Np-237 9.488E-02 0.4946 6.802E-03 0.0355 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.901E-02 0.0991 Pu-238 2.051E-07 0.0000 3.349E-06 0.0000 1.777E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.152E-06 0.0000 Pu-239 4.492E-05 0.0002 9.441E-03 0.0492 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.647E-02 0.1380 Pu-241 1.208E-07 0.0000 2.505E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.986E-08 0.0000 Pu-242 2.060E-05 0.0001 9.292E-03 0.0484 2.104E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.581E-02 0.1346 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 5.992E-16 0.0000 4.679E-18 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.857E-16 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 9.495E-02 0.4949 2.555E-02 0.1332 1.786E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.134E-02 0.3719

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 41 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.938E-06 0.0000 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 1.781E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.407E-08 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.247E-05 0.0002 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.032E-11 0.0000 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.524E-06 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.063E-09 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.207E-01 0.6291 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 3.520E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.452E-05 0.0001 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.596E-02 0.1874 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.158E-07 0.0000 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 1.496E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.513E-02 0.1831 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.895E-16 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 3.538E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.918E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 42 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m+D Ag-110m+D 1.000E+00 1.329E+00 2.155E-01 5.664E-03 1.667E-08 2.622E-24 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 4.887E-02 4.838E-02 4.740E-02 4.414E-02 3.600E-02 1.764E-02 2.297E-03 1.831E-06 Am-241 Np-237+D 1.000E+00 3.822E-08 1.141E-07 2.634E-07 7.612E-07 1.990E-06 4.638E-06 6.206E-06 4.106E-06 Am-241 U-233 1.000E+00 1.411E-15 9.839E-15 5.153E-14 4.460E-13 3.424E-12 2.708E-11 1.077E-10 1.490E-10 Am-241 Th-229+D 1.000E+00 1.989E-18 2.974E-17 3.446E-16 8.915E-15 2.032E-13 5.726E-12 8.334E-11 6.472E-10 Am-241 DSR(j) 4.887E-02 4.838E-02 4.740E-02 4.414E-02 3.600E-02 1.764E-02 2.303E-03 5.938E-06 C-14 C-14 1.000E+00 6.031E-05 9.730E-07 2.508E-10 6.201E-23 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Ce-144+D Ce-144+D 1.000E+00 3.640E-02 1.494E-02 2.516E-03 4.931E-06 9.049E-14 7.573E-41 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 4.908E-11 1.036E-11 4.620E-13 8.642E-18 2.679E-31 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 1.328E-12 2.804E-13 1.250E-14 2.339E-19 7.250E-33 0.000E+00 0.000E+00 0.000E+00 Cm-242 Pu-238 1.840E-09 1.680E-13 3.027E-13 3.325E-13 3.160E-13 2.693E-13 1.540E-13 3.117E-14 1.163E-16 Cm-242 DSR(j) 1.496E-12 5.831E-13 3.450E-13 3.160E-13 2.693E-13 1.540E-13 3.117E-14 1.163E-16 Cm-242 Cm-242 1.000E+00 7.218E-04 1.524E-04 6.794E-06 1.271E-10 3.940E-24 0.000E+00 0.000E+00 0.000E+00 Cm-242 Pu-238 1.000E+00 9.128E-05 1.645E-04 1.807E-04 1.717E-04 1.464E-04 8.369E-05 1.694E-05 6.322E-08 Cm-242 U-234 1.000E+00 1.500E-11 7.554E-11 2.310E-10 7.654E-10 2.069E-09 4.673E-09 4.777E-09 5.645E-10 Cm-242 Th-230 1.000E+00 8.134E-17 9.477E-16 7.130E-15 7.838E-14 6.641E-13 5.752E-12 2.678E-11 5.657E-11 Cm-242 Ra-226+D 1.000E+00 1.151E-17 2.892E-16 5.029E-15 1.763E-13 4.504E-12 1.316E-10 1.842E-09 1.020E-08 Cm-242 Pb-210+D 1.000E+00 1.419E-22 7.419E-21 2.842E-19 2.992E-17 2.055E-15 1.453E-13 3.283E-12 2.255E-11 Cm-242 Po-210 1.000E+00 1.067E-23 9.492E-22 5.626E-20 8.443E-18 6.629E-16 4.923E-14 1.128E-12 7.775E-12 Cm-242 DSR(j) 8.131E-04 3.169E-04 1.875E-04 1.717E-04 1.464E-04 8.369E-05 1.695E-05 7.407E-08 Cm-243 Cm-243 2.400E-03 3.035E-04 2.962E-04 2.820E-04 2.377E-04 1.458E-04 2.633E-05 1.981E-07 7.328E-15 Cm-243 Am-243+D 2.400E-03 2.165E-08 6.399E-08 1.445E-07 3.866E-07 8.133E-07 9.224E-07 2.026E-07 4.689E-10 Cm-243 Pu-239 2.400E-03 4.332E-14 3.004E-13 1.554E-12 1.289E-11 8.796E-11 4.905E-10 1.072E-09 1.120E-09 Cm-243 U-235+D 2.400E-03 3.555E-23 5.291E-22 6.066E-21 1.511E-19 3.097E-18 6.268E-17 4.516E-16 1.026E-15 Cm-243 Pa-231 2.400E-03 1.712E-28 5.271E-27 1.308E-25 9.675E-24 5.872E-22 4.151E-20 9.650E-19 6.004E-18 Cm-243 Ac-227+D 2.400E-03 3.735E-30 2.325E-28 1.212E-26 2.534E-24 4.028E-22 6.888E-20 2.584E-18 1.921E-17 Cm-243 DSR(j) 3.035E-04 2.962E-04 2.822E-04 2.381E-04 1.466E-04 2.725E-05 4.018E-07 1.589E-09 Cm-243 Cm-243 9.976E-01 1.261E-01 1.231E-01 1.172E-01 9.879E-02 6.058E-02 1.094E-02 8.236E-05 3.046E-12 Cm-243 Pu-239 9.976E-01 5.752E-07 1.707E-06 3.889E-06 1.073E-05 2.489E-05 4.303E-05 4.601E-05 4.246E-05 Cm-243 U-235+D 9.976E-01 6.296E-16 4.372E-15 2.270E-14 1.905E-13 1.348E-12 8.568E-12 2.600E-11 3.997E-11 Cm-243 Pa-231 9.976E-01 3.790E-21 5.647E-20 6.490E-19 1.631E-17 3.434E-16 7.631E-15 7.031E-14 2.475E-13 Cm-243 Ac-227+D 9.976E-01 9.912E-23 3.035E-21 7.442E-20 5.275E-18 2.852E-16 1.449E-14 1.987E-13 7.964E-13 Cm-243 DSR(j) 1.261E-01 1.231E-01 1.172E-01 9.880E-02 6.061E-02 1.099E-02 1.284E-04 4.246E-05 Co-57 Co-57 1.000E+00 5.571E-02 2.188E-02 3.374E-03 4.858E-06 3.694E-14 1.415E-42 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 2.714E-01 7.597E-03 5.950E-06 8.000E-17 0.000E+00 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 43 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 2.560E+00 2.244E+00 1.725E+00 6.861E-01 4.928E-02 4.894E-06 1.788E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 1.348E+00 9.633E-01 4.918E-01 4.674E-02 5.618E-05 3.382E-15 2.102E-44 0.000E+00 Cs-137+D Cs-137+D 1.000E+00 5.655E-01 5.526E-01 5.276E-01 4.487E-01 2.824E-01 5.590E-02 5.461E-04 5.032E-11 Eu-154 Eu-154 1.000E+00 1.244E+00 1.150E+00 9.819E-01 5.649E-01 1.164E-01 4.624E-04 6.385E-11 6.246E-35 Fe-55 Fe-55 1.000E+00 4.552E-06 3.521E-06 2.106E-06 3.488E-07 2.047E-09 3.173E-17 1.541E-39 0.000E+00 H-3 H-3 1.000E+00 1.128E-04 2.122E-05 7.489E-07 6.026E-12 1.342E-26 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 3.555E-03 2.050E-03 6.815E-04 1.444E-05 2.383E-10 4.350E-27 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 5.937E-01 2.638E-01 5.211E-02 1.784E-04 1.610E-11 3.561E-36 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 1.115E+00 4.978E-01 9.924E-02 3.510E-04 3.478E-11 1.065E-35 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.829E-06 1.829E-06 1.828E-06 1.826E-06 1.819E-06 1.796E-06 1.732E-06 1.524E-06 Ni-63 Ni-63 1.000E+00 4.981E-06 4.944E-06 4.872E-06 4.626E-06 3.990E-06 2.378E-06 5.420E-07 3.063E-09 Np-237+D Np-237+D 1.000E+00 2.368E-01 2.366E-01 2.363E-01 2.352E-01 2.320E-01 2.213E-01 1.934E-01 1.207E-01 Np-237+D U-233 1.000E+00 1.310E-08 3.923E-08 9.117E-08 2.696E-07 7.516E-07 2.149E-06 4.360E-06 4.500E-06 Np-237+D Th-229+D 1.000E+00 2.461E-11 1.721E-10 9.069E-10 8.034E-09 6.588E-08 6.495E-07 4.471E-06 2.276E-05 Np-237+D DSR(j) 2.368E-01 2.366E-01 2.363E-01 2.352E-01 2.320E-01 2.213E-01 1.934E-01 1.207E-01 Pu-238 Pu-238 1.840E-09 6.703E-11 6.650E-11 6.544E-11 6.188E-11 5.275E-11 3.016E-11 6.105E-12 2.278E-14 Pu-238 Pu-238 1.000E+00 3.643E-02 3.614E-02 3.557E-02 3.363E-02 2.867E-02 1.639E-02 3.318E-03 1.238E-05 Pu-238 U-234 1.000E+00 8.057E-09 2.405E-08 5.549E-08 1.600E-07 4.147E-07 9.225E-07 9.392E-07 1.109E-07 Pu-238 Th-230 1.000E+00 5.455E-14 3.806E-13 1.997E-12 1.740E-11 1.361E-10 1.144E-09 5.284E-09 1.114E-08 Pu-238 Ra-226+D 1.000E+00 9.228E-15 1.380E-13 1.599E-12 4.136E-11 9.419E-10 2.635E-08 3.643E-07 2.008E-06 Pu-238 Pb-210+D 1.000E+00 1.322E-19 4.064E-18 1.006E-16 7.373E-15 4.370E-13 2.920E-11 6.496E-10 4.442E-09 Pu-238 Po-210 1.000E+00 1.104E-20 5.631E-19 2.084E-17 2.101E-15 1.412E-13 9.895E-12 2.231E-10 1.531E-09 Pu-238 DSR(j) 3.643E-02 3.614E-02 3.557E-02 3.363E-02 2.867E-02 1.639E-02 3.319E-03 1.452E-05 Pu-239 Pu-239 1.000E+00 4.036E-02 4.036E-02 4.035E-02 4.032E-02 4.022E-02 3.990E-02 3.899E-02 3.596E-02 Pu-239 U-235+D 1.000E+00 6.611E-11 1.980E-10 4.604E-10 1.364E-09 3.825E-09 1.117E-08 2.425E-08 3.404E-08 Pu-239 Pa-231 1.000E+00 5.300E-16 3.702E-15 1.948E-14 1.714E-13 1.380E-12 1.274E-11 7.309E-11 2.141E-10 Pu-239 Ac-227+D 1.000E+00 1.729E-17 2.568E-16 2.929E-15 7.171E-14 1.413E-12 2.687E-11 2.113E-10 6.900E-10 Pu-239 DSR(j) 4.036E-02 4.036E-02 4.035E-02 4.032E-02 4.022E-02 3.990E-02 3.899E-02 3.596E-02

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 44 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Pu-241 Pu-241 1.000E+00 7.605E-04 7.247E-04 6.581E-04 4.696E-04 1.790E-04 6.122E-06 3.966E-10 8.681E-25 Pu-241 Am-241 1.000E+00 3.863E-05 1.129E-04 2.489E-04 6.126E-04 1.042E-03 7.275E-04 9.687E-05 7.723E-08 Pu-241 Np-237+D 1.000E+00 2.021E-11 1.391E-10 7.080E-10 5.550E-09 3.288E-08 1.326E-07 2.061E-07 1.385E-07 Pu-241 U-233 1.000E+00 5.608E-19 8.302E-18 9.403E-17 2.245E-15 4.130E-14 6.424E-13 3.349E-12 4.996E-12 Pu-241 Th-229+D 1.000E+00 6.332E-22 1.942E-20 4.779E-19 3.434E-17 1.936E-15 1.156E-13 2.385E-12 2.098E-11 Pu-241 DSR(j) 7.992E-04 8.377E-04 9.070E-04 1.082E-03 1.221E-03 7.337E-04 9.707E-05 2.157E-07 Pu-241+D Pu-241+D 2.450E-05 2.186E-06 2.083E-06 1.891E-06 1.350E-06 5.145E-07 1.759E-08 1.140E-12 2.495E-27 Pu-241+D Np-237+D 2.450E-05 9.247E-13 2.715E-12 6.043E-12 1.542E-11 2.964E-11 3.663E-11 3.228E-11 2.014E-11 Pu-241+D U-233 2.450E-05 3.425E-20 2.362E-19 1.208E-18 9.622E-18 5.988E-17 2.904E-16 6.932E-16 7.480E-16 Pu-241+D Th-229+D 2.450E-05 4.836E-23 7.175E-22 8.166E-21 1.985E-19 3.853E-18 7.311E-17 6.561E-16 3.666E-15 Pu-241+D DSR(j) 2.186E-06 2.083E-06 1.891E-06 1.350E-06 5.145E-07 1.763E-08 3.342E-11 2.014E-11 Pu-242 Pu-242 5.500E-06 2.111E-07 2.111E-07 2.110E-07 2.109E-07 2.105E-07 2.092E-07 2.056E-07 1.932E-07 Pu-242 Pu-242 5.400E-05 2.073E-06 2.072E-06 2.072E-06 2.071E-06 2.067E-06 2.054E-06 2.018E-06 1.897E-06 Pu-242 U-238 5.400E-05 2.123E-17 6.359E-17 1.478E-16 4.381E-16 1.229E-15 3.592E-15 7.822E-15 1.115E-14 Pu-242 DSR(j) 2.073E-06 2.072E-06 2.072E-06 2.071E-06 2.067E-06 2.054E-06 2.018E-06 1.897E-06 Pu-242 Pu-242 9.999E-01 3.838E-02 3.838E-02 3.837E-02 3.835E-02 3.828E-02 3.804E-02 3.737E-02 3.512E-02 Pu-242 U-238+D 9.999E-01 2.385E-12 7.145E-12 1.661E-11 4.923E-11 1.381E-10 4.036E-10 8.789E-10 1.253E-09 Pu-242 U-234 9.999E-01 4.175E-19 2.917E-18 1.535E-17 1.351E-16 1.087E-15 1.005E-14 5.785E-14 1.718E-13 Pu-242 Th-230 9.999E-01 2.119E-24 3.173E-23 3.689E-22 9.666E-21 2.283E-19 7.243E-18 1.395E-16 1.943E-15 Pu-242 Ra-226+D 9.999E-01 2.867E-25 8.871E-24 2.226E-22 1.716E-20 1.170E-18 1.200E-16 9.390E-15 2.485E-13 Pu-242 Pb-210+D 9.999E-01 3.423E-30 2.143E-28 1.130E-26 2.468E-24 4.430E-22 1.124E-19 1.042E-17 4.996E-16 Pu-242 Po-210 9.999E-01 2.521E-31 2.655E-29 2.143E-27 6.730E-25 1.406E-22 3.787E-20 3.571E-18 1.721E-16 Pu-242 DSR(j) 3.838E-02 3.838E-02 3.837E-02 3.835E-02 3.828E-02 3.804E-02 3.737E-02 3.512E-02 Ru-106+D Ru-106+D 1.000E+00 1.126E-01 2.529E-02 1.274E-03 3.662E-08 3.870E-21 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 3.895E-01 2.593E-03 1.150E-07 6.674E-23 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 1.957E-01 6.805E-02 8.224E-03 5.048E-06 3.357E-15 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 5.781E-02 2.010E-02 2.429E-03 1.491E-06 9.913E-16 0.000E+00 0.000E+00 0.000E+00 Sb-125 Te-125m 2.280E-01 2.804E-04 1.408E-04 1.711E-05 1.050E-08 6.983E-18 0.000E+00 0.000E+00 0.000E+00 Sb-125 DSR(j) 5.809E-02 2.024E-02 2.446E-03 1.501E-06 9.983E-16 0.000E+00 0.000E+00 0.000E+00 Sn-113+D Sn-113+D 1.000E+00 7.837E-02 3.879E-03 9.502E-06 6.913E-15 5.379E-41 0.000E+00 0.000E+00 0.000E+00 Sr-90+D Sr-90+D 1.000E+00 5.374E-03 5.218E-03 4.918E-03 3.999E-03 2.215E-03 2.799E-04 7.593E-07 7.895E-16 Tc-99 Tc-99 1.000E+00 2.331E-05 1.041E-05 2.075E-06 7.341E-09 7.278E-16 2.234E-40 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 2.844E-01 4.498E-02 1.125E-03 2.780E-09 2.657E-25 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 45 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95+D Zr-95+D 1.000E+00 1.879E-01 3.592E-03 1.313E-06 1.225E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Zr-95+D Nb-95 1.000E+00 1.718E-01 6.560E-03 2.419E-06 2.258E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Zr-95+D DSR(j) 3.597E-01 1.015E-02 3.732E-06 3.484E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life ó 30 days) daughters.

Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m 1.881E+01 1.160E+02 4.414E+03 1.500E+09 *4.754E+15 *4.754E+15 *4.754E+15 *4.754E+15 Am-241 5.115E+02 5.168E+02 5.274E+02 5.664E+02 6.945E+02 1.417E+03 1.085E+04 4.210E+06 C-14 4.145E+05 2.569E+07 9.970E+10 *4.455E+12 *4.455E+12 *4.455E+12 *4.455E+12 *4.455E+12 Ce-144 6.867E+02 1.673E+03 9.937E+03 5.070E+06 2.763E+14 *3.191E+15 *3.191E+15 *3.191E+15 Cm-242 3.075E+04 7.888E+04 1.333E+05 1.456E+05 1.708E+05 2.987E+05 1.475E+06 3.375E+08 Cm-243 1.977E+02 2.026E+02 2.127E+02 2.524E+02 4.115E+02 2.270E+03 1.941E+05 5.887E+05 Co-57 4.487E+02 1.143E+03 7.410E+03 5.146E+06 6.768E+14 *8.465E+15 *8.465E+15 *8.465E+15 Co-58 9.210E+01 3.291E+03 4.202E+06 *3.183E+16 *3.183E+16 *3.183E+16 *3.183E+16 *3.183E+16 Co-60 9.765E+00 1.114E+01 1.450E+01 3.644E+01 5.073E+02 5.108E+06 *1.132E+15 *1.132E+15 Cs-134 1.854E+01 2.595E+01 5.084E+01 5.348E+02 4.450E+05 *1.295E+15 *1.295E+15 *1.295E+15 Cs-137 4.421E+01 4.524E+01 4.738E+01 5.572E+01 8.851E+01 4.473E+02 4.578E+04 4.968E+11 Eu-154 2.009E+01 2.174E+01 2.546E+01 4.426E+01 2.148E+02 5.406E+04 3.915E+11 *2.639E+14 Fe-55 5.492E+06 7.100E+06 1.187E+07 7.168E+07 1.221E+10 *2.410E+15 *2.410E+15 *2.410E+15 H-3 2.216E+05 1.178E+06 3.338E+07 4.148E+12 *9.597E+15 *9.597E+15 *9.597E+15 *9.597E+15 I-129 7.032E+03 1.220E+04 3.668E+04 1.731E+06 *1.766E+08 *1.766E+08 *1.766E+08 *1.766E+08 Mn-54 4.211E+01 9.475E+01 4.798E+02 1.401E+05 1.552E+12 *7.746E+15 *7.746E+15 *7.746E+15 Nb-94 2.242E+01 5.022E+01 2.519E+02 7.123E+04 *1.875E+11 *1.875E+11 *1.875E+11 *1.875E+11 Ni-59 1.367E+07 1.367E+07 1.367E+07 1.369E+07 1.374E+07 1.392E+07 1.444E+07 1.641E+07 Ni-63 5.019E+06 5.056E+06 5.132E+06 5.404E+06 6.266E+06 1.051E+07 4.613E+07 8.161E+09 Np-237 1.056E+02 1.057E+02 1.058E+02 1.063E+02 1.077E+02 1.129E+02 1.292E+02 2.071E+02 Pu-238 6.863E+02 6.918E+02 7.029E+02 7.433E+02 8.721E+02 1.525E+03 7.532E+03 1.722E+06 Pu-239 6.194E+02 6.194E+02 6.196E+02 6.201E+02 6.215E+02 6.266E+02 6.412E+02 6.953E+02 Pu-241 3.120E+04 2.977E+04 2.750E+04 2.307E+04 2.047E+04 3.407E+04 2.575E+05 1.159E+08 Pu-242 6.514E+02 6.514E+02 6.515E+02 6.519E+02 6.531E+02 6.572E+02 6.689E+02 7.117E+02 Ru-106 2.219E+02 9.886E+02 1.962E+04 6.827E+08 *3.348E+15 *3.348E+15 *3.348E+15 *3.348E+15 Sb-124 6.419E+01 9.640E+03 2.174E+08 *1.750E+16 *1.750E+16 *1.750E+16 *1.750E+16 *1.750E+16 Sb-125 9.849E+01 2.832E+02 2.343E+03 3.817E+06 *1.033E+15 *1.033E+15 *1.033E+15 *1.033E+15 Sn-113 3.190E+02 6.445E+03 2.631E+06 3.616E+15 *1.005E+16 *1.005E+16 *1.005E+16 *1.005E+16 Sr-90 4.652E+03 4.791E+03 5.083E+03 6.251E+03 1.129E+04 8.932E+04 3.292E+07 *1.365E+14 Tc-99 1.072E+06 2.402E+06 1.205E+07 3.406E+09 *1.697E+10 *1.697E+10 *1.697E+10 *1.697E+10 Zn-65 8.790E+01 5.559E+02 2.223E+04 8.992E+09 *8.245E+15 *8.245E+15 *8.245E+15 *8.245E+15 Zr-95 6.951E+01 2.463E+03 6.699E+06 *2.150E+16 *2.150E+16 *2.150E+16 *2.150E+16 *2.150E+16

  • At specific activity limit

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 46 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)

(i) (pCi/g) (years) (pCi/g) (pCi/g)

Ag-110m 1.000E+00 0.000E+00 1.329E+00 1.881E+01 1.329E+00 1.881E+01 Am-241 1.000E+00 0.000E+00 4.887E-02 5.115E+02 4.887E-02 5.115E+02 C-14 1.000E+00 0.000E+00 6.031E-05 4.145E+05 6.031E-05 4.145E+05 Ce-144 1.000E+00 0.000E+00 3.640E-02 6.867E+02 3.640E-02 6.867E+02 Cm-242 1.000E+00 0.000E+00 8.131E-04 3.075E+04 8.131E-04 3.075E+04 Cm-243 1.000E+00 0.000E+00 1.265E-01 1.977E+02 1.265E-01 1.977E+02 Co-57 1.000E+00 0.000E+00 5.571E-02 4.487E+02 5.571E-02 4.487E+02 Co-58 1.000E+00 0.000E+00 2.714E-01 9.210E+01 2.714E-01 9.210E+01 Co-60 1.000E+00 0.000E+00 2.560E+00 9.765E+00 2.560E+00 9.765E+00 Cs-134 1.000E+00 0.000E+00 1.348E+00 1.854E+01 1.348E+00 1.854E+01 Cs-137 1.000E+00 0.000E+00 5.655E-01 4.421E+01 5.655E-01 4.421E+01 Eu-154 1.000E+00 0.000E+00 1.244E+00 2.009E+01 1.244E+00 2.009E+01 Fe-55 1.000E+00 0.000E+00 4.552E-06 5.492E+06 4.552E-06 5.492E+06 H-3 1.000E+00 0.000E+00 1.128E-04 2.216E+05 1.128E-04 2.216E+05 I-129 1.000E+00 0.000E+00 3.555E-03 7.032E+03 3.555E-03 7.032E+03 Mn-54 1.000E+00 0.000E+00 5.937E-01 4.211E+01 5.937E-01 4.211E+01 Nb-94 1.000E+00 0.000E+00 1.115E+00 2.242E+01 1.115E+00 2.242E+01 Ni-59 1.000E+00 0.000E+00 1.829E-06 1.367E+07 1.829E-06 1.367E+07 Ni-63 1.000E+00 0.000E+00 4.981E-06 5.019E+06 4.981E-06 5.019E+06 Np-237 1.000E+00 0.000E+00 2.368E-01 1.056E+02 2.368E-01 1.056E+02 Pu-238 1.000E+00 0.000E+00 3.643E-02 6.863E+02 3.643E-02 6.863E+02 Pu-239 1.000E+00 0.000E+00 4.036E-02 6.194E+02 4.036E-02 6.194E+02 Pu-241 1.000E+00 27.92 n 0.06 1.223E-03 2.044E+04 8.014E-04 3.120E+04 Pu-242 1.000E+00 0.000E+00 3.838E-02 6.514E+02 3.838E-02 6.514E+02 Ru-106 1.000E+00 0.000E+00 1.126E-01 2.219E+02 1.126E-01 2.219E+02 Sb-124 1.000E+00 0.000E+00 3.895E-01 6.419E+01 3.895E-01 6.419E+01 Sb-125 1.000E+00 0.000E+00 2.538E-01 9.849E+01 2.538E-01 9.849E+01 Sn-113 1.000E+00 0.000E+00 7.837E-02 3.190E+02 7.837E-02 3.190E+02 Sr-90 1.000E+00 0.000E+00 5.374E-03 4.652E+03 5.374E-03 4.652E+03 Tc-99 1.000E+00 0.000E+00 2.331E-05 1.072E+06 2.331E-05 1.072E+06 Zn-65 1.000E+00 0.000E+00 2.844E-01 8.790E+01 2.844E-01 8.790E+01 Zr-95 1.000E+00 0.000E+00 3.597E-01 6.951E+01 3.597E-01 6.951E+01

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 47 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m Ag-110m 1.000E+00 1.329E+00 2.155E-01 5.664E-03 1.667E-08 2.622E-24 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 4.887E-02 4.838E-02 4.740E-02 4.414E-02 3.600E-02 1.764E-02 2.297E-03 1.831E-06 Am-241 Pu-241 1.000E+00 3.863E-05 1.129E-04 2.489E-04 6.126E-04 1.042E-03 7.275E-04 9.687E-05 7.723E-08 Am-241 DOSE(j) 4.891E-02 4.849E-02 4.765E-02 4.475E-02 3.704E-02 1.836E-02 2.394E-03 1.909E-06 Np-237 Am-241 1.000E+00 3.822E-08 1.141E-07 2.634E-07 7.612E-07 1.990E-06 4.638E-06 6.206E-06 4.106E-06 Np-237 Np-237 1.000E+00 2.368E-01 2.366E-01 2.363E-01 2.352E-01 2.320E-01 2.213E-01 1.934E-01 1.207E-01 Np-237 Pu-241 1.000E+00 2.021E-11 1.391E-10 7.080E-10 5.550E-09 3.288E-08 1.326E-07 2.061E-07 1.385E-07 Np-237 Pu-241 2.450E-05 9.247E-13 2.715E-12 6.043E-12 1.542E-11 2.964E-11 3.663E-11 3.228E-11 2.014E-11 Np-237 DOSE(j) 2.368E-01 2.366E-01 2.363E-01 2.352E-01 2.320E-01 2.214E-01 1.934E-01 1.207E-01 U-233 Am-241 1.000E+00 1.411E-15 9.839E-15 5.153E-14 4.460E-13 3.424E-12 2.708E-11 1.077E-10 1.490E-10 U-233 Np-237 1.000E+00 1.310E-08 3.923E-08 9.117E-08 2.696E-07 7.516E-07 2.149E-06 4.360E-06 4.500E-06 U-233 Pu-241 1.000E+00 5.608E-19 8.302E-18 9.403E-17 2.245E-15 4.130E-14 6.424E-13 3.349E-12 4.996E-12 U-233 Pu-241 2.450E-05 3.425E-20 2.362E-19 1.208E-18 9.622E-18 5.988E-17 2.904E-16 6.932E-16 7.480E-16 U-233 DOSE(j) 1.310E-08 3.923E-08 9.117E-08 2.696E-07 7.516E-07 2.149E-06 4.360E-06 4.500E-06 Th-229 Am-241 1.000E+00 1.989E-18 2.974E-17 3.446E-16 8.915E-15 2.032E-13 5.726E-12 8.334E-11 6.472E-10 Th-229 Np-237 1.000E+00 2.461E-11 1.721E-10 9.069E-10 8.034E-09 6.588E-08 6.495E-07 4.471E-06 2.276E-05 Th-229 Pu-241 1.000E+00 6.332E-22 1.942E-20 4.779E-19 3.434E-17 1.936E-15 1.156E-13 2.385E-12 2.098E-11 Th-229 Pu-241 2.450E-05 4.836E-23 7.175E-22 8.166E-21 1.985E-19 3.853E-18 7.311E-17 6.561E-16 3.666E-15 Th-229 DOSE(j) 2.461E-11 1.721E-10 9.069E-10 8.034E-09 6.588E-08 6.495E-07 4.471E-06 2.276E-05 C-14 C-14 1.000E+00 6.031E-05 9.730E-07 2.508E-10 6.201E-23 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Ce-144 Ce-144 1.000E+00 3.640E-02 1.494E-02 2.516E-03 4.931E-06 9.049E-14 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 4.908E-11 1.036E-11 4.620E-13 8.642E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 1.328E-12 2.804E-13 1.250E-14 2.339E-19 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Cm-242 DOSE(j) 5.041E-11 1.064E-11 4.745E-13 8.876E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.840E-09 1.680E-13 3.027E-13 3.325E-13 3.160E-13 2.693E-13 1.540E-13 3.117E-14 1.163E-16 Pu-238 Pu-238 1.840E-09 6.703E-11 6.650E-11 6.544E-11 6.188E-11 5.275E-11 3.016E-11 6.105E-12 2.278E-14 Pu-238 DOSE(j) 6.720E-11 6.680E-11 6.578E-11 6.220E-11 5.302E-11 3.031E-11 6.136E-12 2.290E-14 Cm-242 Cm-242 1.000E+00 7.218E-04 1.524E-04 6.794E-06 1.271E-10 3.940E-24 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.000E+00 9.128E-05 1.645E-04 1.807E-04 1.717E-04 1.464E-04 8.369E-05 1.694E-05 6.322E-08 U-234 Cm-242 1.000E+00 1.500E-11 7.554E-11 2.310E-10 7.654E-10 2.069E-09 4.673E-09 4.777E-09 5.645E-10 U-234 Pu-238 1.000E+00 8.057E-09 2.405E-08 5.549E-08 1.600E-07 4.147E-07 9.225E-07 9.392E-07 1.109E-07 U-234 Pu-242 9.999E-01 4.175E-19 2.917E-18 1.535E-17 1.351E-16 1.087E-15 1.005E-14 5.785E-14 1.718E-13 U-234 DOSE(j) 8.072E-09 2.413E-08 5.572E-08 1.607E-07 4.167E-07 9.272E-07 9.440E-07 1.115E-07 Th-230 Cm-242 1.000E+00 8.134E-17 9.477E-16 7.130E-15 7.838E-14 6.641E-13 5.752E-12 2.678E-11 5.657E-11 Th-230 Pu-238 1.000E+00 5.455E-14 3.806E-13 1.997E-12 1.740E-11 1.361E-10 1.144E-09 5.284E-09 1.114E-08 Th-230 Pu-242 9.999E-01 2.119E-24 3.173E-23 3.689E-22 9.666E-21 2.283E-19 7.243E-18 1.395E-16 1.943E-15 Th-230 DOSE(j) 5.463E-14 3.815E-13 2.004E-12 1.748E-11 1.367E-10 1.150E-09 5.311E-09 1.119E-08

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 48 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ra-226 Cm-242 1.000E+00 1.151E-17 2.892E-16 5.029E-15 1.763E-13 4.504E-12 1.316E-10 1.842E-09 1.020E-08 Ra-226 Pu-238 1.000E+00 9.228E-15 1.380E-13 1.599E-12 4.136E-11 9.419E-10 2.635E-08 3.643E-07 2.008E-06 Ra-226 Pu-242 9.999E-01 2.867E-25 8.871E-24 2.226E-22 1.716E-20 1.170E-18 1.200E-16 9.390E-15 2.485E-13 Ra-226 DOSE(j) 9.240E-15 1.383E-13 1.604E-12 4.153E-11 9.464E-10 2.648E-08 3.661E-07 2.018E-06 Pb-210 Cm-242 1.000E+00 1.419E-22 7.419E-21 2.842E-19 2.992E-17 2.055E-15 1.453E-13 3.283E-12 2.255E-11 Pb-210 Pu-238 1.000E+00 1.322E-19 4.064E-18 1.006E-16 7.373E-15 4.370E-13 2.920E-11 6.496E-10 4.442E-09 Pb-210 Pu-242 9.999E-01 3.322E-30 2.143E-28 1.130E-26 2.468E-24 4.430E-22 1.124E-19 1.042E-17 4.996E-16 Pb-210 DOSE(j) 1.323E-19 4.071E-18 1.009E-16 7.403E-15 4.391E-13 2.934E-11 6.529E-10 4.465E-09 Po-210 Cm-242 1.000E+00 1.067E-23 9.492E-22 5.626E-20 8.443E-18 6.629E-16 4.923E-14 1.128E-12 7.775E-12 Po-210 Pu-238 1.000E+00 1.104E-20 5.631E-19 2.084E-17 2.101E-15 1.412E-13 9.895E-12 2.231E-10 1.531E-09 Po-210 Pu-242 9.999E-01 0.000E+00 2.615E-29 2.143E-27 6.730E-25 1.406E-22 3.787E-20 3.571E-18 1.721E-16 Po-210 DOSE(j) 1.106E-20 5.640E-19 2.089E-17 2.109E-15 1.419E-13 9.945E-12 2.242E-10 1.539E-09 Cm-243 Cm-243 2.400E-03 3.035E-04 2.962E-04 2.820E-04 2.377E-04 1.458E-04 2.633E-05 1.981E-07 7.328E-15 Cm-243 Cm-243 9.976E-01 1.261E-01 1.231E-01 1.172E-01 9.879E-02 6.058E-02 1.094E-02 8.236E-05 3.046E-12 Cm-243 DOSE(j) 1.265E-01 1.234E-01 1.175E-01 9.903E-02 6.073E-02 1.097E-02 8.256E-05 3.053E-12 Am-243 Cm-243 2.400E-03 2.165E-08 6.399E-08 1.445E-07 3.866E-07 8.133E-07 9.224E-07 2.026E-07 4.689E-10 Pu-239 Cm-243 2.400E-03 4.332E-14 3.004E-13 1.554E-12 1.289E-11 8.796E-11 4.905E-10 1.072E-09 1.120E-09 Pu-239 Cm-243 9.976E-01 5.752E-07 1.707E-06 3.889E-06 1.073E-05 2.489E-05 4.303E-05 4.601E-05 4.246E-05 Pu-239 Pu-239 1.000E+00 4.036E-02 4.036E-02 4.035E-02 4.032E-02 4.022E-02 3.990E-02 3.899E-02 3.596E-02 Pu-239 DOSE(j) 4.037E-02 4.036E-02 4.035E-02 4.033E-02 4.025E-02 3.994E-02 3.903E-02 3.600E-02 U-235 Cm-243 2.400E-03 3.555E-23 5.291E-22 6.066E-21 1.511E-19 3.097E-18 6.268E-17 4.516E-16 1.026E-15 U-235 Cm-243 9.976E-01 6.296E-16 4.372E-15 2.270E-14 1.905E-13 1.348E-12 8.568E-12 2.600E-11 3.997E-11 U-235 Pu-239 1.000E+00 6.611E-11 1.980E-10 4.604E-10 1.364E-09 3.825E-09 1.117E-08 2.425E-08 3.404E-08 U-235 DOSE(j) 6.611E-11 1.980E-10 4.605E-10 1.364E-09 3.827E-09 1.118E-08 2.427E-08 3.408E-08 Pa-231 Cm-243 2.400E-03 1.712E-28 5.271E-27 1.308E-25 9.675E-24 5.872E-22 4.151E-20 9.650E-19 6.004E-18 Pa-231 Cm-243 9.976E-01 3.790E-21 5.647E-20 6.490E-19 1.631E-17 3.434E-16 7.631E-15 7.031E-14 2.475E-13 Pa-231 Pu-239 1.000E+00 5.300E-16 3.702E-15 1.948E-14 1.714E-13 1.380E-12 1.274E-11 7.309E-11 2.141E-10 Pa-231 DOSE(j) 5.300E-16 3.702E-15 1.948E-14 1.715E-13 1.380E-12 1.275E-11 7.316E-11 2.143E-10 Ac-227 Cm-243 2.400E-03 2.018E-30 2.325E-28 1.212E-26 2.534E-24 4.028E-22 6.888E-20 2.584E-18 1.921E-17 Ac-227 Cm-243 9.976E-01 9.912E-23 3.035E-21 7.442E-20 5.275E-18 2.852E-16 1.449E-14 1.987E-13 7.964E-13 Ac-227 Pu-239 1.000E+00 1.729E-17 2.568E-16 2.929E-15 7.171E-14 1.413E-12 2.687E-11 2.113E-10 6.900E-10 Ac-227 DOSE(j) 1.729E-17 2.568E-16 2.929E-15 7.172E-14 1.413E-12 2.688E-11 2.115E-10 6.908E-10 Co-57 Co-57 1.000E+00 5.571E-02 2.188E-02 3.374E-03 4.858E-06 3.694E-14 0.000E+00 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 2.714E-01 7.597E-03 5.950E-06 8.000E-17 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Co-60 Co-60 1.000E+00 2.560E+00 2.244E+00 1.725E+00 6.861E-01 4.928E-02 4.894E-06 1.788E-17 0.000E+00 Cs-134 Cs-134 1.000E+00 1.348E+00 9.633E-01 4.918E-01 4.674E-02 5.618E-05 3.382E-15 0.000E+00 0.000E+00 Cs-137 Cs-137 1.000E+00 5.655E-01 5.526E-01 5.276E-01 4.487E-01 2.824E-01 5.590E-02 5.461E-04 5.032E-11

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 49 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Eu-154 Eu-154 1.000E+00 1.244E+00 1.150E+00 9.819E-01 5.649E-01 1.164E-01 4.624E-04 6.385E-11 0.000E+00 Fe-55 Fe-55 1.000E+00 4.552E-06 3.521E-06 2.106E-06 3.488E-07 2.047E-09 3.173E-17 0.000E+00 0.000E+00 H-3 H-3 1.000E+00 1.128E-04 2.122E-05 7.489E-07 6.026E-12 1.342E-26 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 3.555E-03 2.050E-03 6.815E-04 1.444E-05 2.383E-10 4.350E-27 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 5.937E-01 2.638E-01 5.211E-02 1.784E-04 1.610E-11 0.000E+00 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 1.115E+00 4.978E-01 9.924E-02 3.510E-04 3.478E-11 0.000E+00 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.829E-06 1.829E-06 1.828E-06 1.826E-06 1.819E-06 1.796E-06 1.732E-06 1.524E-06 Ni-63 Ni-63 1.000E+00 4.981E-06 4.944E-06 4.872E-06 4.626E-06 3.990E-06 2.378E-06 5.420E-07 3.063E-09 Pu-238 Pu-238 1.000E+00 3.643E-02 3.614E-02 3.557E-02 3.363E-02 2.867E-02 1.639E-02 3.318E-03 1.238E-05 Pu-241 Pu-241 1.000E+00 7.605E-04 7.247E-04 6.581E-04 4.696E-04 1.790E-04 6.122E-06 3.966E-10 8.681E-25 Pu-241 Pu-241 2.450E-05 2.186E-06 2.083E-06 1.891E-06 1.350E-06 5.145E-07 1.759E-08 1.140E-12 2.495E-27 Pu-241 DOSE(j) 7.627E-04 7.268E-04 6.600E-04 4.709E-04 1.795E-04 6.139E-06 3.977E-10 8.706E-25 Pu-242 Pu-242 5.500E-06 2.111E-07 2.111E-07 2.110E-07 2.109E-07 2.105E-07 2.092E-07 2.056E-07 1.932E-07 Pu-242 Pu-242 5.400E-05 2.073E-06 2.072E-06 2.072E-06 2.071E-06 2.067E-06 2.054E-06 2.018E-06 1.897E-06 Pu-242 DOSE(j) 2.284E-06 2.283E-06 2.283E-06 2.282E-06 2.278E-06 2.264E-06 2.224E-06 2.090E-06 U-238 Pu-242 5.400E-05 2.123E-17 6.359E-17 1.478E-16 4.381E-16 1.229E-15 3.592E-15 7.822E-15 1.115E-14 U-238 Pu-242 9.999E-01 2.385E-12 7.145E-12 1.661E-11 4.923E-11 1.381E-10 4.036E-10 8.789E-10 1.253E-09 U-238 DOSE(j) 2.385E-12 7.145E-12 1.661E-11 4.923E-11 1.381E-10 4.036E-10 8.789E-10 1.253E-09 Pu-242 Pu-242 9.999E-01 3.838E-02 3.838E-02 3.837E-02 3.835E-02 3.828E-02 3.804E-02 3.737E-02 3.512E-02 Ru-106 Ru-106 1.000E+00 1.126E-01 2.529E-02 1.274E-03 3.662E-08 3.870E-21 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 3.895E-01 2.593E-03 1.150E-07 6.674E-23 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 1.957E-01 6.805E-02 8.224E-03 5.048E-06 3.357E-15 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 5.781E-02 2.010E-02 2.429E-03 1.491E-06 9.913E-16 0.000E+00 0.000E+00 0.000E+00 Sb-125 DOSE(j) 2.535E-01 8.814E-02 1.065E-02 6.538E-06 4.348E-15 0.000E+00 0.000E+00 0.000E+00 Te-125m Sb-125 2.280E-01 2.804E-04 1.408E-04 1.711E-05 1.050E-08 6.983E-18 0.000E+00 0.000E+00 0.000E+00 Sn-113 Sn-113 1.000E+00 7.837E-02 3.879E-03 9.502E-06 6.913E-15 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sr-90 Sr-90 1.000E+00 5.374E-03 5.218E-03 4.918E-03 3.999E-03 2.215E-03 2.799E-04 7.593E-07 7.895E-16 Tc-99 Tc-99 1.000E+00 2.331E-05 1.041E-05 2.075E-06 7.341E-09 7.278E-16 0.000E+00 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 2.844E-01 4.498E-02 1.125E-03 2.780E-09 2.657E-25 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 50 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95 Zr-95 1.000E+00 1.879E-01 3.592E-03 1.313E-06 1.225E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Nb-95 Zr-95 1.000E+00 1.718E-01 6.560E-03 2.419E-06 2.258E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 51 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m Ag-110m 1.000E+00 1.000E+00 1.621E-01 4.261E-03 1.254E-08 1.973E-24 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 1.000E+00 9.899E-01 9.699E-01 9.031E-01 7.366E-01 3.609E-01 4.700E-02 3.747E-05 Am-241 Pu-241 1.000E+00 0.000E+00 1.558E-03 4.410E-03 1.205E-02 2.114E-02 1.488E-02 1.982E-03 1.580E-06 Am-241 S(j): 1.000E+00 9.914E-01 9.743E-01 9.152E-01 7.577E-01 3.758E-01 4.898E-02 3.905E-05 Np-237 Am-241 1.000E+00 0.000E+00 3.221E-07 9.560E-07 3.069E-06 8.284E-06 1.953E-05 2.620E-05 1.734E-05 Np-237 Np-237 1.000E+00 1.000E+00 9.993E-01 9.980E-01 9.933E-01 9.800E-01 9.348E-01 8.169E-01 5.096E-01 Np-237 Pu-241 1.000E+00 0.000E+00 2.547E-10 2.204E-09 2.144E-08 1.354E-07 5.574E-07 8.702E-07 5.849E-07 Np-237 Pu-241 2.450E-05 0.000E+00 7.745E-12 2.214E-11 6.273E-11 1.243E-10 1.547E-10 1.363E-10 8.505E-11 Np-237 S(j): 1.000E+00 9.993E-01 9.980E-01 9.933E-01 9.800E-01 9.348E-01 8.169E-01 5.096E-01 U-233 Am-241 1.000E+00 0.000E+00 7.049E-13 6.284E-12 6.753E-11 5.533E-10 4.479E-09 1.793E-08 2.484E-08 U-233 Np-237 1.000E+00 0.000E+00 4.364E-06 1.304E-05 4.284E-05 1.233E-04 3.568E-04 7.262E-04 7.502E-04 U-233 Pu-241 1.000E+00 0.000E+00 3.727E-16 9.757E-15 3.250E-13 6.594E-12 1.060E-10 5.573E-10 8.328E-10 U-233 Pu-241 2.450E-05 0.000E+00 1.705E-17 1.483E-16 1.466E-15 9.725E-15 4.814E-14 1.154E-13 1.247E-13 U-233 S(j): 0.000E+00 4.364E-06 1.304E-05 4.284E-05 1.233E-04 3.568E-04 7.262E-04 7.502E-04 Th-229 Am-241 1.000E+00 0.000E+00 2.221E-17 5.955E-16 2.151E-14 5.410E-13 1.579E-11 2.320E-10 1.807E-09 Th-229 Np-237 1.000E+00 0.000E+00 2.062E-10 1.851E-09 2.036E-08 1.782E-07 1.798E-06 1.246E-05 6.357E-05 Th-229 Pu-241 1.000E+00 0.000E+00 8.827E-21 6.975E-19 7.907E-17 5.088E-15 3.180E-13 6.638E-12 5.859E-11 Th-229 Pu-241 2.450E-05 0.000E+00 5.391E-22 1.418E-20 4.810E-19 1.030E-17 2.020E-16 1.828E-15 1.024E-14 Th-229 S(j): 0.000E+00 2.062E-10 1.851E-09 2.036E-08 1.782E-07 1.798E-06 1.246E-05 6.357E-05 C-14 C-14 1.000E+00 1.000E+00 1.615E-02 4.167E-06 1.036E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Ce-144 Ce-144 1.000E+00 1.000E+00 4.104E-01 6.911E-02 1.355E-04 2.486E-12 2.080E-39 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 6.800E-08 1.436E-08 6.401E-10 1.197E-14 3.712E-28 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 1.840E-09 3.885E-10 1.732E-11 3.240E-16 1.004E-29 0.000E+00 0.000E+00 0.000E+00 Cm-242 S(j): 6.984E-08 1.475E-08 6.574E-10 1.230E-14 3.812E-28 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.840E-09 0.000E+00 7.336E-12 9.084E-12 8.674E-12 7.393E-12 4.227E-12 8.557E-13 3.193E-15 Pu-238 Pu-238 1.840E-09 1.840E-09 1.825E-09 1.796E-09 1.699E-09 1.448E-09 8.279E-10 1.676E-10 6.254E-13 Pu-238 S(j): 1.840E-09 1.833E-09 1.806E-09 1.707E-09 1.455E-09 8.321E-10 1.684E-10 6.286E-13 Cm-242 Cm-242 1.000E+00 1.000E+00 2.111E-01 9.413E-03 1.761E-07 5.459E-21 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.000E+00 0.000E+00 3.987E-03 4.937E-03 4.714E-03 4.018E-03 2.297E-03 4.650E-04 1.736E-06 U-234 Cm-242 1.000E+00 0.000E+00 7.066E-09 3.354E-08 1.277E-07 3.576E-07 8.171E-07 8.379E-07 9.911E-08 U-234 Pu-238 1.000E+00 0.000E+00 2.819E-06 8.360E-06 2.677E-05 7.169E-05 1.613E-04 1.648E-04 1.947E-05 U-234 Pu-242 9.999E-01 0.000E+00 2.194E-16 1.965E-15 2.148E-14 1.846E-13 1.747E-12 1.012E-11 3.011E-11 U-234 S(j): 0.000E+00 2.826E-06 8.394E-06 2.690E-05 7.204E-05 1.621E-04 1.656E-04 1.957E-05 Th-230 Cm-242 1.000E+00 0.000E+00 2.367E-14 3.826E-13 5.500E-12 5.001E-11 4.435E-10 2.078E-09 4.398E-09 Th-230 Pu-238 1.000E+00 0.000E+00 1.271E-11 1.135E-10 1.228E-09 1.025E-08 8.825E-08 4.101E-07 8.659E-07 Th-230 Pu-242 9.999E-01 0.000E+00 6.587E-22 1.772E-20 6.483E-19 1.691E-17 5.552E-16 1.080E-14 1.509E-13 Th-230 S(j): 0.000E+00 1.274E-11 1.139E-10 1.234E-09 1.030E-08 8.869E-08 4.122E-07 8.703E-07

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 52 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ra-226 Cm-242 1.000E+00 0.000E+00 2.738E-18 1.437E-16 7.512E-15 2.135E-13 6.477E-12 9.192E-11 5.240E-10 Ra-226 Pu-238 1.000E+00 0.000E+00 1.836E-15 4.922E-14 1.778E-12 4.470E-11 1.297E-09 1.818E-08 1.032E-07 Ra-226 Pu-242 9.999E-01 0.000E+00 7.132E-26 5.754E-24 7.006E-22 5.455E-20 5.872E-18 3.253E-16 1.221E-14 Ra-226 S(j): 0.000E+00 1.839E-15 4.936E-14 1.785E-12 4.492E-11 1.304E-09 1.827E-08 1.037E-07 Pb-210 Cm-242 1.000E+00 0.000E+00 1.770E-20 2.917E-18 5.235E-16 4.145E-14 3.072E-12 7.031E-11 4.847E-10 Pb-210 Pu-238 1.000E+00 0.000E+00 1.418E-17 1.128E-15 1.304E-13 8.829E-12 6.176E-10 1.391E-08 9.546E-08 Pb-210 Pu-242 9.999E-01 0.000E+00 4.411E-28 1.057E-25 4.141E-23 8.790E-21 2.364E-18 2.227E-16 1.073E-14 Pb-210 S(j): 0.000E+00 1.420E-17 1.130E-15 1.310E-13 8.870E-12 6.206E-10 1.398E-08 9.595E-08 Po-210 Cm-242 1.000E+00 0.000E+00 4.364E-21 1.515E-18 4.199E-16 3.838E-14 2.991E-12 6.936E-11 4.800E-10 Po-210 Pu-238 1.000E+00 0.000E+00 3.939E-18 6.196E-16 1.058E-13 8.185E-12 6.012E-10 1.372E-08 9.454E-08 Po-210 Pu-242 9.999E-01 0.000E+00 1.059E-28 5.252E-26 3.207E-23 8.003E-21 2.287E-18 2.192E-16 1.061E-14 Po-210 S(j): 0.000E+00 3.943E-18 6.212E-16 1.062E-13 8.223E-12 6.042E-10 1.379E-08 9.502E-08 Cm-243 Cm-243 2.400E-03 2.400E-03 2.342E-03 2.230E-03 1.879E-03 1.153E-03 2.082E-04 1.567E-06 5.795E-14 Cm-243 Cm-243 9.976E-01 9.976E-01 9.735E-01 9.271E-01 7.812E-01 4.791E-01 8.654E-02 6.513E-04 2.409E-11 Cm-243 S(j): 1.000E+00 9.758E-01 9.293E-01 7.831E-01 4.803E-01 8.675E-02 6.529E-04 2.415E-11 Am-243 Cm-243 2.400E-03 0.000E+00 2.217E-07 6.435E-07 1.912E-06 4.153E-06 4.761E-06 1.048E-06 2.425E-09 Pu-239 Cm-243 2.400E-03 0.000E+00 3.211E-12 2.826E-11 2.909E-10 2.119E-09 1.208E-08 2.654E-08 2.774E-08 Pu-239 Cm-243 9.976E-01 0.000E+00 2.838E-05 8.310E-05 2.548E-04 6.097E-04 1.065E-03 1.140E-03 1.052E-03 Pu-239 Pu-239 1.000E+00 1.000E+00 9.999E-01 9.997E-01 9.988E-01 9.965E-01 9.885E-01 9.659E-01 8.908E-01 Pu-239 S(j): 1.000E+00 9.999E-01 9.997E-01 9.991E-01 9.971E-01 9.896E-01 9.671E-01 8.919E-01 U-235 Cm-243 2.400E-03 0.000E+00 1.056E-21 2.800E-20 9.731E-19 2.202E-17 4.611E-16 3.352E-15 7.630E-15 U-235 Cm-243 9.976E-01 0.000E+00 1.402E-14 1.238E-13 1.291E-12 9.745E-12 6.332E-11 1.932E-10 2.973E-10 U-235 Pu-239 1.000E+00 0.000E+00 9.831E-10 2.939E-09 9.675E-09 2.802E-08 8.276E-08 1.802E-07 2.533E-07 U-235 S(j): 0.000E+00 9.831E-10 2.939E-09 9.676E-09 2.803E-08 8.282E-08 1.804E-07 2.536E-07 Pa-231 Cm-243 2.400E-03 0.000E+00 5.592E-27 4.458E-25 5.205E-23 3.608E-21 2.671E-19 6.288E-18 3.927E-17 Pa-231 Cm-243 9.976E-01 0.000E+00 9.901E-20 2.632E-18 9.232E-17 2.145E-15 4.933E-14 4.587E-13 1.619E-12 Pa-231 Pu-239 1.000E+00 0.000E+00 1.039E-14 9.311E-14 1.018E-12 8.741E-12 8.263E-11 4.770E-10 1.400E-09 Pa-231 S(j): 0.000E+00 1.039E-14 9.312E-14 1.018E-12 8.743E-12 8.268E-11 4.775E-10 1.402E-09 Ac-227 Cm-243 2.400E-03 0.000E+00 3.541E-29 8.378E-27 3.143E-24 5.905E-22 1.070E-19 4.074E-18 3.041E-17 Ac-227 Cm-243 9.976E-01 0.000E+00 7.829E-22 6.163E-20 6.892E-18 4.253E-16 2.261E-14 3.137E-13 1.261E-12 Ac-227 Pu-239 1.000E+00 0.000E+00 1.093E-16 2.882E-15 9.845E-14 2.140E-12 4.208E-11 3.338E-10 1.092E-09 Ac-227 S(j): 0.000E+00 1.093E-16 2.882E-15 9.846E-14 2.140E-12 4.211E-11 3.341E-10 1.094E-09 Co-57 Co-57 1.000E+00 1.000E+00 3.927E-01 6.056E-02 8.720E-05 6.630E-13 2.542E-41 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 1.000E+00 2.799E-02 2.192E-05 2.947E-16 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Co-60 Co-60 1.000E+00 1.000E+00 8.766E-01 6.737E-01 2.680E-01 1.925E-02 1.912E-06 6.986E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 1.000E+00 7.145E-01 3.647E-01 3.467E-02 4.167E-05 2.509E-15 1.541E-44 0.000E+00 Cs-137 Cs-137 1.000E+00 1.000E+00 9.771E-01 9.329E-01 7.934E-01 4.994E-01 9.884E-02 9.656E-04 8.898E-11

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 53 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Eu-154 Eu-154 1.000E+00 1.000E+00 9.241E-01 7.890E-01 4.539E-01 9.354E-02 3.716E-04 5.131E-11 5.020E-35 Fe-55 Fe-55 1.000E+00 1.000E+00 7.734E-01 4.627E-01 7.662E-02 4.497E-04 6.970E-12 3.385E-34 0.000E+00 H-3 H-3 1.000E+00 1.000E+00 1.881E-01 6.643E-03 5.357E-08 1.201E-22 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 1.000E+00 5.766E-01 1.917E-01 4.062E-03 6.703E-08 1.224E-24 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 1.000E+00 4.444E-01 8.777E-02 3.005E-04 2.713E-11 5.997E-36 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 1.000E+00 4.465E-01 8.900E-02 3.148E-04 3.119E-11 9.553E-36 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.000E+00 9.998E-01 9.995E-01 9.982E-01 9.945E-01 9.819E-01 9.466E-01 8.329E-01 Ni-63 Ni-63 1.000E+00 1.000E+00 9.926E-01 9.781E-01 9.287E-01 8.011E-01 4.774E-01 1.088E-01 6.150E-04 Pu-238 Pu-238 1.000E+00 1.000E+00 9.920E-01 9.763E-01 9.232E-01 7.869E-01 4.499E-01 9.108E-02 3.399E-04 Pu-241 Pu-241 1.000E+00 1.000E+00 9.529E-01 8.653E-01 6.174E-01 2.353E-01 8.049E-03 5.215E-07 1.141E-21 Pu-241 Pu-241 2.450E-05 2.450E-05 2.335E-05 2.120E-05 1.513E-05 5.766E-06 1.972E-07 1.278E-11 2.796E-26 Pu-241 S(j): 1.000E+00 9.529E-01 8.653E-01 6.174E-01 2.354E-01 8.049E-03 5.215E-07 1.141E-21 Pu-242 Pu-242 5.500E-06 5.500E-06 5.500E-06 5.499E-06 5.495E-06 5.485E-06 5.451E-06 5.356E-06 5.033E-06 Pu-242 Pu-242 5.400E-05 5.400E-05 5.399E-05 5.399E-05 5.395E-05 5.386E-05 5.352E-05 5.258E-05 4.942E-05 Pu-242 S(j): 5.950E-05 5.949E-05 5.948E-05 5.945E-05 5.934E-05 5.897E-05 5.794E-05 5.445E-05 U-238 Pu-242 5.400E-05 0.000E+00 8.362E-15 2.500E-14 8.230E-14 2.384E-13 7.049E-13 1.540E-12 2.197E-12 U-238 Pu-242 9.999E-01 0.000E+00 1.549E-10 4.629E-10 1.524E-09 4.415E-09 1.305E-08 2.852E-08 4.069E-08 U-238 S(j): 0.000E+00 1.549E-10 4.629E-10 1.524E-09 4.415E-09 1.305E-08 2.852E-08 4.069E-08 Pu-242 Pu-242 9.999E-01 9.999E-01 9.999E-01 9.997E-01 9.991E-01 9.973E-01 9.911E-01 9.737E-01 9.151E-01 Ru-106 Ru-106 1.000E+00 1.000E+00 2.245E-01 1.131E-02 3.251E-07 3.435E-20 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 1.000E+00 6.659E-03 2.952E-07 1.713E-22 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 7.720E-01 2.684E-01 3.244E-02 1.991E-05 1.324E-14 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 2.280E-01 7.926E-02 9.580E-03 5.880E-06 3.910E-15 0.000E+00 0.000E+00 0.000E+00 Sb-125 S(j): 1.000E+00 3.476E-01 4.202E-02 2.579E-05 1.715E-14 0.000E+00 0.000E+00 0.000E+00 Te-125m Sb-125 2.280E-01 0.000E+00 8.271E-02 1.016E-02 6.237E-06 4.148E-15 0.000E+00 0.000E+00 0.000E+00 Sn-113 Sn-113 1.000E+00 1.000E+00 4.949E-02 1.212E-04 8.821E-14 6.863E-40 0.000E+00 0.000E+00 0.000E+00 Sr-90 Sr-90 1.000E+00 1.000E+00 9.709E-01 9.152E-01 7.442E-01 4.121E-01 5.208E-02 1.413E-04 1.469E-13 Tc-99 Tc-99 1.000E+00 1.000E+00 4.465E-01 8.901E-02 3.149E-04 3.122E-11 9.582E-36 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 1.000E+00 1.581E-01 3.954E-03 9.775E-09 9.340E-25 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 12:59 Page 54 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413INDUSTRIAL.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95 Zr-95 1.000E+00 1.000E+00 1.912E-02 6.988E-06 6.523E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Nb-95 Zr-95 1.000E+00 0.000E+00 3.339E-02 1.242E-05 1.160E-17 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

RESCALC.EXE execution time = 66.99 seconds

DRE-13-001 Revision 1 SRRS: 2B.134 ENCLOSURE 6 RESRAD Version 6.5 Report for Dresden 10CFR20.2002 Pad DCGL Evaluation - Recreationist Scenario (56 pages total)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 1 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary... 2 Site-Specific Parameter Summary.......................... 13 Summary of Pathway Selections............................ 24 Contaminated Zone and Total Dose Summary................. 25 Total Dose Components Time = 0.000E+00.................................... 28 Time = 1.000E+00.................................... 30 Time = 3.000E+00.................................... 32 Time = 1.000E+01.................................... 34 Time = 3.000E+01.................................... 36 Time = 1.000E+02.................................... 38 Time = 3.000E+02.................................... 40 Time = 1.000E+03.................................... 42 Dose/Source Ratios Summed Over All Pathways.............. 44 Single Radionuclide Soil Guidelines...................... 47 Dose Per Nuclide Summed Over All Pathways................ 49 Soil Concentration Per Nuclide........................... 53

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 2 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ A-1 ³ DCF's for external ground radiation, (mrem/yr)/(pCi/g) ³ ³ ³ A-1 ³ Ac-225 (Source: FGR 12) ³ 6.371E-02 ³ 6.371E-02 ³ DCF1( 1)

A-1 ³ Ac-227 (Source: FGR 12) ³ 4.951E-04 ³ 4.951E-04 ³ DCF1( 2)

A-1 ³ Ag-110 (Source: FGR 12) ³ 2.242E-01 ³ 2.242E-01 ³ DCF1( 3)

A-1 ³ Ag-110m (Source: FGR 12) ³ 1.717E+01 ³ 1.717E+01 ³ DCF1( 4)

A-1 ³ Am-241 (Source: FGR 12) ³ 4.372E-02 ³ 4.372E-02 ³ DCF1( 5)

A-1 ³ Am-243 (Source: FGR 12) ³ 1.420E-01 ³ 1.420E-01 ³ DCF1( 6)

A-1 ³ At-217 (Source: FGR 12) ³ 1.773E-03 ³ 1.773E-03 ³ DCF1( 7)

A-1 ³ At-218 (Source: FGR 12) ³ 5.847E-03 ³ 5.847E-03 ³ DCF1( 8)

A-1 ³ Ba-137m (Source: FGR 12) ³ 3.606E+00 ³ 3.606E+00 ³ DCF1( 9)

A-1 ³ Bi-210 (Source: FGR 12) ³ 3.606E-03 ³ 3.606E-03 ³ DCF1( 10)

A-1 ³ Bi-211 (Source: FGR 12) ³ 2.559E-01 ³ 2.559E-01 ³ DCF1( 11)

A-1 ³ Bi-213 (Source: FGR 12) ³ 7.660E-01 ³ 7.660E-01 ³ DCF1( 12)

A-1 ³ Bi-214 (Source: FGR 12) ³ 9.808E+00 ³ 9.808E+00 ³ DCF1( 13)

A-1 ³ C-14 (Source: FGR 12) ³ 1.345E-05 ³ 1.345E-05 ³ DCF1( 14)

A-1 ³ Ce-144 (Source: FGR 12) ³ 7.174E-02 ³ 7.174E-02 ³ DCF1( 15)

A-1 ³ Cm-242 (Source: FGR 12) ³ 1.709E-04 ³ 1.709E-04 ³ DCF1( 16)

A-1 ³ Cm-243 (Source: FGR 12) ³ 5.829E-01 ³ 5.829E-01 ³ DCF1( 17)

A-1 ³ Co-57 (Source: FGR 12) ³ 5.007E-01 ³ 5.007E-01 ³ DCF1( 18)

A-1 ³ Co-58 (Source: FGR 12) ³ 5.960E+00 ³ 5.960E+00 ³ DCF1( 19)

A-1 ³ Co-60 (Source: FGR 12) ³ 1.622E+01 ³ 1.622E+01 ³ DCF1( 20)

A-1 ³ Cs-134 (Source: FGR 12) ³ 9.472E+00 ³ 9.472E+00 ³ DCF1( 21)

A-1 ³ Cs-137 (Source: FGR 12) ³ 7.510E-04 ³ 7.510E-04 ³ DCF1( 22)

A-1 ³ Eu-154 (Source: FGR 12) ³ 7.678E+00 ³ 7.678E+00 ³ DCF1( 23)

A-1 ³ Fe-55 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 24)

A-1 ³ Fr-221 (Source: FGR 12) ³ 1.536E-01 ³ 1.536E-01 ³ DCF1( 25)

A-1 ³ Fr-223 (Source: FGR 12) ³ 1.980E-01 ³ 1.980E-01 ³ DCF1( 26)

A-1 ³ H-3 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 27)

A-1 ³ I-129 (Source: FGR 12) ³ 1.295E-02 ³ 1.295E-02 ³ DCF1( 28)

A-1 ³ In-113m (Source: FGR 12) ³ 1.435E+00 ³ 1.435E+00 ³ DCF1( 29)

A-1 ³ Mn-54 (Source: FGR 12) ³ 5.156E+00 ³ 5.156E+00 ³ DCF1( 30)

A-1 ³ Nb-94 (Source: FGR 12) ³ 9.677E+00 ³ 9.677E+00 ³ DCF1( 31)

A-1 ³ Nb-95 (Source: FGR 12) ³ 4.689E+00 ³ 4.689E+00 ³ DCF1( 32)

A-1 ³ Nb-95m (Source: FGR 12) ³ 3.195E-01 ³ 3.195E-01 ³ DCF1( 33)

A-1 ³ Ni-59 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 34)

A-1 ³ Ni-63 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 35)

A-1 ³ Np-237 (Source: FGR 12) ³ 7.790E-02 ³ 7.790E-02 ³ DCF1( 36)

A-1 ³ Np-239 (Source: FGR 12) ³ 7.529E-01 ³ 7.529E-01 ³ DCF1( 37)

A-1 ³ Pa-231 (Source: FGR 12) ³ 1.906E-01 ³ 1.906E-01 ³ DCF1( 38)

A-1 ³ Pa-233 (Source: FGR 12) ³ 1.020E+00 ³ 1.020E+00 ³ DCF1( 39)

A-1 ³ Pa-234 (Source: FGR 12) ³ 1.155E+01 ³ 1.155E+01 ³ DCF1( 40)

A-1 ³ Pa-234m (Source: FGR 12) ³ 8.967E-02 ³ 8.967E-02 ³ DCF1( 41)

A-1 ³ Pb-209 (Source: FGR 12) ³ 7.734E-04 ³ 7.734E-04 ³ DCF1( 42)

A-1 ³ Pb-210 (Source: FGR 12) ³ 2.447E-03 ³ 2.447E-03 ³ DCF1( 43)

A-1 ³ Pb-211 (Source: FGR 12) ³ 3.064E-01 ³ 3.064E-01 ³ DCF1( 44)

A-1 ³ Pb-214 (Source: FGR 12) ³ 1.341E+00 ³ 1.341E+00 ³ DCF1( 45)

A-1 ³ Po-210 (Source: FGR 12) ³ 5.231E-05 ³ 5.231E-05 ³ DCF1( 46)

A-1 ³ Po-211 (Source: FGR 12) ³ 4.764E-02 ³ 4.764E-02 ³ DCF1( 47)

A-1 ³ Po-213 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 48)

A-1 ³ Po-214 (Source: FGR 12) ³ 5.138E-04 ³ 5.138E-04 ³ DCF1( 49)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 3 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ A-1 ³ Po-215 (Source: FGR 12) ³ 1.016E-03 ³ 1.016E-03 ³ DCF1( 50)

A-1 ³ Po-218 (Source: FGR 12) ³ 5.642E-05 ³ 5.642E-05 ³ DCF1( 51)

A-1 ³ Pr-144 (Source: FGR 12) ³ 2.522E-01 ³ 2.522E-01 ³ DCF1( 52)

A-1 ³ Pr-144m (Source: FGR 12) ³ 1.437E-02 ³ 1.437E-02 ³ DCF1( 53)

A-1 ³ Pu-238 (Source: FGR 12) ³ 1.513E-04 ³ 1.513E-04 ³ DCF1( 54)

A-1 ³ Pu-239 (Source: FGR 12) ³ 2.952E-04 ³ 2.952E-04 ³ DCF1( 55)

A-1 ³ Pu-241 (Source: FGR 12) ³ 5.904E-06 ³ 5.904E-06 ³ DCF1( 56)

A-1 ³ Pu-242 (Source: FGR 12) ³ 1.280E-04 ³ 1.280E-04 ³ DCF1( 57)

A-1 ³ Ra-223 (Source: FGR 12) ³ 6.034E-01 ³ 6.034E-01 ³ DCF1( 58)

A-1 ³ Ra-225 (Source: FGR 12) ³ 1.102E-02 ³ 1.102E-02 ³ DCF1( 59)

A-1 ³ Ra-226 (Source: FGR 12) ³ 3.176E-02 ³ 3.176E-02 ³ DCF1( 60)

A-1 ³ Rh-106 (Source: FGR 12) ³ 1.291E+00 ³ 1.291E+00 ³ DCF1( 61)

A-1 ³ Rn-219 (Source: FGR 12) ³ 3.083E-01 ³ 3.083E-01 ³ DCF1( 62)

A-1 ³ Rn-222 (Source: FGR 12) ³ 2.354E-03 ³ 2.354E-03 ³ DCF1( 63)

A-1 ³ Ru-106 (Source: FGR 12) ³ 0.000E+00 ³ 0.000E+00 ³ DCF1( 64)

A-1 ³ Sb-124 (Source: FGR 12) ³ 1.169E+01 ³ 1.169E+01 ³ DCF1( 65)

A-1 ³ Sb-125 (Source: FGR 12) ³ 2.447E+00 ³ 2.447E+00 ³ DCF1( 66)

A-1 ³ Sn-113 (Source: FGR 12) ³ 2.970E-02 ³ 2.970E-02 ³ DCF1( 67)

A-1 ³ Sr-90 (Source: FGR 12) ³ 7.043E-04 ³ 7.043E-04 ³ DCF1( 68)

A-1 ³ Tc-99 (Source: FGR 12) ³ 1.255E-04 ³ 1.255E-04 ³ DCF1( 69)

A-1 ³ Te-125m (Source: FGR 12) ³ 1.515E-02 ³ 1.515E-02 ³ DCF1( 70)

A-1 ³ Th-227 (Source: FGR 12) ³ 5.212E-01 ³ 5.212E-01 ³ DCF1( 71)

A-1 ³ Th-229 (Source: FGR 12) ³ 3.213E-01 ³ 3.213E-01 ³ DCF1( 72)

A-1 ³ Th-230 (Source: FGR 12) ³ 1.209E-03 ³ 1.209E-03 ³ DCF1( 73)

A-1 ³ Th-231 (Source: FGR 12) ³ 3.643E-02 ³ 3.643E-02 ³ DCF1( 74)

A-1 ³ Th-234 (Source: FGR 12) ³ 2.410E-02 ³ 2.410E-02 ³ DCF1( 75)

A-1 ³ Tl-207 (Source: FGR 12) ³ 1.980E-02 ³ 1.980E-02 ³ DCF1( 76)

A-1 ³ Tl-209 (Source: FGR 12) ³ 1.293E+01 ³ 1.293E+01 ³ DCF1( 77)

A-1 ³ Tl-210 (Source: no data) ³ 0.000E+00 ³-2.000E+00 ³ DCF1( 78)

A-1 ³ U-233 (Source: FGR 12) ³ 1.397E-03 ³ 1.397E-03 ³ DCF1( 79)

A-1 ³ U-234 (Source: FGR 12) ³ 4.017E-04 ³ 4.017E-04 ³ DCF1( 80)

A-1 ³ U-235 (Source: FGR 12) ³ 7.211E-01 ³ 7.211E-01 ³ DCF1( 81)

A-1 ³ U-237 (Source: FGR 12) ³ 5.306E-01 ³ 5.306E-01 ³ DCF1( 82)

A-1 ³ U-238 (Source: FGR 12) ³ 1.031E-04 ³ 1.031E-04 ³ DCF1( 83)

A-1 ³ Y-90 (Source: FGR 12) ³ 2.391E-02 ³ 2.391E-02 ³ DCF1( 84)

A-1 ³ Zn-65 (Source: FGR 12) ³ 3.699E+00 ³ 3.699E+00 ³ DCF1( 85)

A-1 ³ Zr-95 (Source: FGR 12) ³ 4.521E+00 ³ 4.521E+00 ³ DCF1( 86)

³ ³ ³ ³ B-1 ³ Dose conversion factors for inhalation, mrem/pCi: ³ ³ ³ B-1 ³ Ac-227+D ³ 6.724E+00 ³ 6.700E+00 ³ DCF2( 1)

B-1 ³ Ag-110m+D ³ 8.030E-05 ³ 8.030E-05 ³ DCF2( 2)

B-1 ³ Am-241 ³ 4.440E-01 ³ 4.440E-01 ³ DCF2( 3)

B-1 ³ Am-243+D ³ 4.400E-01 ³ 4.400E-01 ³ DCF2( 4)

B-1 ³ C-14(p) (Class: ORGANIC) ³ 2.090E-06 ³ 2.090E-06 ³ DCF2( 5)

B-1 ³ C-14(g) (Class: CO2) ³ 2.350E-08 ³ 2.350E-08 ³ C14GInhDCF B-1 ³ Ce-144+D ³ 3.740E-04 ³ 3.740E-04 ³ DCF2( 6)

B-1 ³ Cm-242 ³ 1.730E-02 ³ 1.730E-02 ³ DCF2( 7)

B-1 ³ Cm-243 ³ 3.070E-01 ³ 3.070E-01 ³ DCF2( 10)

B-1 ³ Co-57 ³ 9.070E-06 ³ 9.070E-06 ³ DCF2( 12)

B-1 ³ Co-58 ³ 1.090E-05 ³ 1.090E-05 ³ DCF2( 13)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 4 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ B-1 ³ Co-60 ³ 2.190E-04 ³ 2.190E-04 ³ DCF2( 14)

B-1 ³ Cs-134 ³ 4.620E-05 ³ 4.620E-05 ³ DCF2( 15)

B-1 ³ Cs-137+D ³ 3.190E-05 ³ 3.190E-05 ³ DCF2( 16)

B-1 ³ Eu-154 ³ 2.860E-04 ³ 2.860E-04 ³ DCF2( 17)

B-1 ³ Fe-55 ³ 2.690E-06 ³ 2.690E-06 ³ DCF2( 18)

B-1 ³ H-3 ³ 6.400E-08 ³ 6.400E-08 ³ DCF2( 19)

B-1 ³ I-129 ³ 1.740E-04 ³ 1.740E-04 ³ DCF2( 20)

B-1 ³ Mn-54 ³ 6.700E-06 ³ 6.700E-06 ³ DCF2( 21)

B-1 ³ Nb-94 ³ 4.140E-04 ³ 4.140E-04 ³ DCF2( 22)

B-1 ³ Nb-95 ³ 5.810E-06 ³ 5.810E-06 ³ DCF2( 23)

B-1 ³ Ni-59 ³ 2.700E-06 ³ 2.700E-06 ³ DCF2( 24)

B-1 ³ Ni-63 ³ 6.290E-06 ³ 6.290E-06 ³ DCF2( 25)

B-1 ³ Np-237+D ³ 5.400E-01 ³ 5.400E-01 ³ DCF2( 26)

B-1 ³ Pa-231 ³ 1.280E+00 ³ 1.280E+00 ³ DCF2( 27)

B-1 ³ Pb-210+D ³ 1.380E-02 ³ 1.360E-02 ³ DCF2( 28)

B-1 ³ Po-210 ³ 9.400E-03 ³ 9.400E-03 ³ DCF2( 29)

B-1 ³ Pu-238 ³ 3.920E-01 ³ 3.920E-01 ³ DCF2( 30)

B-1 ³ Pu-239 ³ 4.290E-01 ³ 4.290E-01 ³ DCF2( 32)

B-1 ³ Pu-241 ³ 8.250E-03 ³ 8.250E-03 ³ DCF2( 33)

B-1 ³ Pu-241+D ³ 8.254E-03 ³ 8.250E-03 ³ DCF2( 34)

B-1 ³ Pu-242 ³ 4.110E-01 ³ 4.110E-01 ³ DCF2( 35)

B-1 ³ Ra-226+D ³ 8.594E-03 ³ 8.580E-03 ³ DCF2( 38)

B-1 ³ Ru-106+D ³ 4.770E-04 ³ 4.770E-04 ³ DCF2( 39)

B-1 ³ Sb-124 ³ 2.520E-05 ³ 2.520E-05 ³ DCF2( 40)

B-1 ³ Sb-125 ³ 1.220E-05 ³ 1.220E-05 ³ DCF2( 41)

B-1 ³ Sn-113+D ³ 1.074E-05 ³ 1.070E-05 ³ DCF2( 43)

B-1 ³ Sr-90+D ³ 1.308E-03 ³ 1.300E-03 ³ DCF2( 44)

B-1 ³ Tc-99 ³ 8.320E-06 ³ 8.320E-06 ³ DCF2( 45)

B-1 ³ Te-125m ³ 7.290E-06 ³ 7.290E-06 ³ DCF2( 46)

B-1 ³ Th-229+D ³ 2.169E+00 ³ 2.150E+00 ³ DCF2( 47)

B-1 ³ Th-230 ³ 3.260E-01 ³ 3.260E-01 ³ DCF2( 48)

B-1 ³ U-233 ³ 1.350E-01 ³ 1.350E-01 ³ DCF2( 49)

B-1 ³ U-234 ³ 1.320E-01 ³ 1.320E-01 ³ DCF2( 50)

B-1 ³ U-235+D ³ 1.230E-01 ³ 1.230E-01 ³ DCF2( 51)

B-1 ³ U-238 ³ 1.180E-01 ³ 1.180E-01 ³ DCF2( 52)

B-1 ³ U-238+D ³ 1.180E-01 ³ 1.180E-01 ³ DCF2( 53)

B-1 ³ Zn-65 ³ 2.040E-05 ³ 2.040E-05 ³ DCF2( 54)

B-1 ³ Zr-95+D ³ 2.362E-05 ³ 2.360E-05 ³ DCF2( 55)

³ ³ ³ ³ D-1 ³ Dose conversion factors for ingestion, mrem/pCi: ³ ³ ³ D-1 ³ Ac-227+D ³ 1.480E-02 ³ 1.410E-02 ³ DCF3( 1)

D-1 ³ Ag-110m+D ³ 1.080E-05 ³ 1.080E-05 ³ DCF3( 2)

D-1 ³ Am-241 ³ 3.640E-03 ³ 3.640E-03 ³ DCF3( 3)

D-1 ³ Am-243+D ³ 3.623E-03 ³ 3.620E-03 ³ DCF3( 4)

D-1 ³ C-14 ³ 2.090E-06 ³ 2.090E-06 ³ DCF3( 5)

D-1 ³ Ce-144+D ³ 2.112E-05 ³ 2.100E-05 ³ DCF3( 6)

D-1 ³ Cm-242 ³ 1.150E-04 ³ 1.150E-04 ³ DCF3( 7)

D-1 ³ Cm-243 ³ 2.510E-03 ³ 2.510E-03 ³ DCF3( 10)

D-1 ³ Co-57 ³ 1.180E-06 ³ 1.180E-06 ³ DCF3( 12)

D-1 ³ Co-58 ³ 3.580E-06 ³ 3.580E-06 ³ DCF3( 13)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 5 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-1 ³ Co-60 ³ 2.690E-05 ³ 2.690E-05 ³ DCF3( 14)

D-1 ³ Cs-134 ³ 7.330E-05 ³ 7.330E-05 ³ DCF3( 15)

D-1 ³ Cs-137+D ³ 5.000E-05 ³ 5.000E-05 ³ DCF3( 16)

D-1 ³ Eu-154 ³ 9.550E-06 ³ 9.550E-06 ³ DCF3( 17)

D-1 ³ Fe-55 ³ 6.070E-07 ³ 6.070E-07 ³ DCF3( 18)

D-1 ³ H-3 ³ 6.400E-08 ³ 6.400E-08 ³ DCF3( 19)

D-1 ³ I-129 ³ 2.760E-04 ³ 2.760E-04 ³ DCF3( 20)

D-1 ³ Mn-54 ³ 2.770E-06 ³ 2.770E-06 ³ DCF3( 21)

D-1 ³ Nb-94 ³ 7.140E-06 ³ 7.140E-06 ³ DCF3( 22)

D-1 ³ Nb-95 ³ 2.570E-06 ³ 2.570E-06 ³ DCF3( 23)

D-1 ³ Ni-59 ³ 2.100E-07 ³ 2.100E-07 ³ DCF3( 24)

D-1 ³ Ni-63 ³ 5.770E-07 ³ 5.770E-07 ³ DCF3( 25)

D-1 ³ Np-237+D ³ 4.444E-03 ³ 4.440E-03 ³ DCF3( 26)

D-1 ³ Pa-231 ³ 1.060E-02 ³ 1.060E-02 ³ DCF3( 27)

D-1 ³ Pb-210+D ³ 5.376E-03 ³ 5.370E-03 ³ DCF3( 28)

D-1 ³ Po-210 ³ 1.900E-03 ³ 1.900E-03 ³ DCF3( 29)

D-1 ³ Pu-238 ³ 3.200E-03 ³ 3.200E-03 ³ DCF3( 30)

D-1 ³ Pu-239 ³ 3.540E-03 ³ 3.540E-03 ³ DCF3( 32)

D-1 ³ Pu-241 ³ 6.840E-05 ³ 6.840E-05 ³ DCF3( 33)

D-1 ³ Pu-241+D ³ 7.157E-05 ³ 6.840E-05 ³ DCF3( 34)

D-1 ³ Pu-242 ³ 3.360E-03 ³ 3.360E-03 ³ DCF3( 35)

D-1 ³ Ra-226+D ³ 1.321E-03 ³ 1.320E-03 ³ DCF3( 38)

D-1 ³ Ru-106+D ³ 2.740E-05 ³ 2.740E-05 ³ DCF3( 39)

D-1 ³ Sb-124 ³ 1.010E-05 ³ 1.010E-05 ³ DCF3( 40)

D-1 ³ Sb-125 ³ 2.810E-06 ³ 2.810E-06 ³ DCF3( 41)

D-1 ³ Sn-113+D ³ 3.185E-06 ³ 3.080E-06 ³ DCF3( 43)

D-1 ³ Sr-90+D ³ 1.528E-04 ³ 1.420E-04 ³ DCF3( 44)

D-1 ³ Tc-99 ³ 1.460E-06 ³ 1.460E-06 ³ DCF3( 45)

D-1 ³ Te-125m ³ 3.670E-06 ³ 3.670E-06 ³ DCF3( 46)

D-1 ³ Th-229+D ³ 4.027E-03 ³ 3.530E-03 ³ DCF3( 47)

D-1 ³ Th-230 ³ 5.480E-04 ³ 5.480E-04 ³ DCF3( 48)

D-1 ³ U-233 ³ 2.890E-04 ³ 2.890E-04 ³ DCF3( 49)

D-1 ³ U-234 ³ 2.830E-04 ³ 2.830E-04 ³ DCF3( 50)

D-1 ³ U-235+D ³ 2.673E-04 ³ 2.660E-04 ³ DCF3( 51)

D-1 ³ U-238 ³ 2.550E-04 ³ 2.550E-04 ³ DCF3( 52)

D-1 ³ U-238+D ³ 2.687E-04 ³ 2.550E-04 ³ DCF3( 53)

D-1 ³ Zn-65 ³ 1.440E-05 ³ 1.440E-05 ³ DCF3( 54)

D-1 ³ Zr-95+D ³ 3.786E-06 ³ 3.770E-06 ³ DCF3( 55)

³ ³ ³ ³ D-34 ³ Food transfer factors: ³ ³ ³ D-34 ³ Ac-227+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 1,1)

D-34 ³ Ac-227+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 1,2)

D-34 ³ Ac-227+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 1,3)

D-34 ³ ³ ³ ³ D-34 ³ Ag-110m+D, plant/soil concentration ratio, dimensionless ³ 1.500E-01 ³ 1.500E-01 ³ RTF( 2,1)

D-34 ³ Ag-110m+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-03 ³ 3.000E-03 ³ RTF( 2,2)

D-34 ³ Ag-110m+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.500E-02 ³ 2.500E-02 ³ RTF( 2,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 6 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Am-241, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 3,1)

D-34 ³ Am-241, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 3,2)

D-34 ³ Am-241, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 3,3)

D-34 ³ ³ ³ ³ D-34 ³ Am-243+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 4,1)

D-34 ³ Am-243+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 4,2)

D-34 ³ Am-243+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 4,3)

D-34 ³ ³ ³ ³ D-34 ³ C-14, plant/soil concentration ratio, dimensionless ³ 5.500E+00 ³ 5.500E+00 ³ RTF( 5,1)

D-34 ³ C-14, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.100E-02 ³ 3.100E-02 ³ RTF( 5,2)

D-34 ³ C-14, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.200E-02 ³ 1.200E-02 ³ RTF( 5,3)

D-34 ³ ³ ³ ³ D-34 ³ Ce-144+D, plant/soil concentration ratio, dimensionless ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 6,1)

D-34 ³ Ce-144+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 6,2)

D-34 ³ Ce-144+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 6,3)

D-34 ³ ³ ³ ³ D-34 ³ Cm-242, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 7,1)

D-34 ³ Cm-242, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 7,2)

D-34 ³ Cm-242, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 7,3)

D-34 ³ ³ ³ ³ D-34 ³ Cm-243, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 10,1)

D-34 ³ Cm-243, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-05 ³ 2.000E-05 ³ RTF( 10,2)

D-34 ³ Cm-243, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 10,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-57, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 12,1)

D-34 ³ Co-57, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 12,2)

D-34 ³ Co-57, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 12,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-58, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 13,1)

D-34 ³ Co-58, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 13,2)

D-34 ³ Co-58, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 13,3)

D-34 ³ ³ ³ ³ D-34 ³ Co-60, plant/soil concentration ratio, dimensionless ³ 8.000E-02 ³ 8.000E-02 ³ RTF( 14,1)

D-34 ³ Co-60, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 14,2)

D-34 ³ Co-60, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 14,3)

D-34 ³ ³ ³ ³ D-34 ³ Cs-134, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 15,1)

D-34 ³ Cs-134, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 15,2)

D-34 ³ Cs-134, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 15,3)

D-34 ³ ³ ³ ³ D-34 ³ Cs-137+D, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 16,1)

D-34 ³ Cs-137+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 16,2)

D-34 ³ Cs-137+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 16,3)

D-34 ³ ³ ³ ³ D-34 ³ Eu-154, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 17,1)

D-34 ³ Eu-154, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 17,2)

D-34 ³ Eu-154, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-05 ³ 5.000E-05 ³ RTF( 17,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 7 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Fe-55, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 18,1)

D-34 ³ Fe-55, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 18,2)

D-34 ³ Fe-55, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 18,3)

D-34 ³ ³ ³ ³ D-34 ³ H-3, plant/soil concentration ratio, dimensionless ³ 4.800E+00 ³ 4.800E+00 ³ RTF( 19,1)

D-34 ³ H-3, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.200E-02 ³ 1.200E-02 ³ RTF( 19,2)

D-34 ³ H-3, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 19,3)

D-34 ³ ³ ³ ³ D-34 ³ I-129, plant/soil concentration ratio, dimensionless ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 20,1)

D-34 ³ I-129, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 7.000E-03 ³ 7.000E-03 ³ RTF( 20,2)

D-34 ³ I-129, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 20,3)

D-34 ³ ³ ³ ³ D-34 ³ Mn-54, plant/soil concentration ratio, dimensionless ³ 3.000E-01 ³ 3.000E-01 ³ RTF( 21,1)

D-34 ³ Mn-54, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-04 ³ 5.000E-04 ³ RTF( 21,2)

D-34 ³ Mn-54, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 21,3)

D-34 ³ ³ ³ ³ D-34 ³ Nb-94, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 22,1)

D-34 ³ Nb-94, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-07 ³ 3.000E-07 ³ RTF( 22,2)

D-34 ³ Nb-94, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 22,3)

D-34 ³ ³ ³ ³ D-34 ³ Nb-95, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 23,1)

D-34 ³ Nb-95, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.000E-07 ³ 3.000E-07 ³ RTF( 23,2)

D-34 ³ Nb-95, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-06 ³ 2.000E-06 ³ RTF( 23,3)

D-34 ³ ³ ³ ³ D-34 ³ Ni-59, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 24,1)

D-34 ³ Ni-59, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 24,2)

D-34 ³ Ni-59, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 24,3)

D-34 ³ ³ ³ ³ D-34 ³ Ni-63, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 25,1)

D-34 ³ Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 25,2)

D-34 ³ Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 25,3)

D-34 ³ ³ ³ ³ D-34 ³ Np-237+D, plant/soil concentration ratio, dimensionless ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 26,1)

D-34 ³ Np-237+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 26,2)

D-34 ³ Np-237+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 26,3)

D-34 ³ ³ ³ ³ D-34 ³ Pa-231, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 27,1)

D-34 ³ Pa-231, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 27,2)

D-34 ³ Pa-231, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 27,3)

D-34 ³ ³ ³ ³ D-34 ³ Pb-210+D, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 28,1)

D-34 ³ Pb-210+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 8.000E-04 ³ 8.000E-04 ³ RTF( 28,2)

D-34 ³ Pb-210+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.000E-04 ³ 3.000E-04 ³ RTF( 28,3)

D-34 ³ ³ ³ ³ D-34 ³ Po-210, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 29,1)

D-34 ³ Po-210, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 29,2)

D-34 ³ Po-210, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 29,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 8 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Pu-238, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 30,1)

D-34 ³ Pu-238, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 30,2)

D-34 ³ Pu-238, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 30,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-239, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 32,1)

D-34 ³ Pu-239, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 32,2)

D-34 ³ Pu-239, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 32,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-241, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 33,1)

D-34 ³ Pu-241, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 33,2)

D-34 ³ Pu-241, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 33,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-241+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 34,1)

D-34 ³ Pu-241+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 34,2)

D-34 ³ Pu-241+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 34,3)

D-34 ³ ³ ³ ³ D-34 ³ Pu-242, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 35,1)

D-34 ³ Pu-242, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 35,2)

D-34 ³ Pu-242, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 35,3)

D-34 ³ ³ ³ ³ D-34 ³ Ra-226+D, plant/soil concentration ratio, dimensionless ³ 4.000E-02 ³ 4.000E-02 ³ RTF( 38,1)

D-34 ³ Ra-226+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 38,2)

D-34 ³ Ra-226+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 38,3)

D-34 ³ ³ ³ ³ D-34 ³ Ru-106+D, plant/soil concentration ratio, dimensionless ³ 3.000E-02 ³ 3.000E-02 ³ RTF( 39,1)

D-34 ³ Ru-106+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 39,2)

D-34 ³ Ru-106+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 3.300E-06 ³ 3.300E-06 ³ RTF( 39,3)

D-34 ³ ³ ³ ³ D-34 ³ Sb-124, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 40,1)

D-34 ³ Sb-124, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 40,2)

D-34 ³ Sb-124, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 40,3)

D-34 ³ ³ ³ ³ D-34 ³ Sb-125, plant/soil concentration ratio, dimensionless ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 41,1)

D-34 ³ Sb-125, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 41,2)

D-34 ³ Sb-125, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 41,3)

D-34 ³ ³ ³ ³ D-34 ³ Sn-113+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 43,1)

D-34 ³ Sn-113+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 43,2)

D-34 ³ Sn-113+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 43,3)

D-34 ³ ³ ³ ³ D-34 ³ Sr-90+D, plant/soil concentration ratio, dimensionless ³ 3.000E-01 ³ 3.000E-01 ³ RTF( 44,1)

D-34 ³ Sr-90+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 8.000E-03 ³ 8.000E-03 ³ RTF( 44,2)

D-34 ³ Sr-90+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-03 ³ 2.000E-03 ³ RTF( 44,3)

D-34 ³ ³ ³ ³ D-34 ³ Tc-99, plant/soil concentration ratio, dimensionless ³ 5.000E+00 ³ 5.000E+00 ³ RTF( 45,1)

D-34 ³ Tc-99, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 45,2)

D-34 ³ Tc-99, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 45,3)

D-34 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 9 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-34 ³ Te-125m, plant/soil concentration ratio, dimensionless ³ 6.000E-01 ³ 6.000E-01 ³ RTF( 46,1)

D-34 ³ Te-125m, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 7.000E-03 ³ 7.000E-03 ³ RTF( 46,2)

D-34 ³ Te-125m, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-04 ³ 5.000E-04 ³ RTF( 46,3)

D-34 ³ ³ ³ ³ D-34 ³ Th-229+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 47,1)

D-34 ³ Th-229+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 47,2)

D-34 ³ Th-229+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 47,3)

D-34 ³ ³ ³ ³ D-34 ³ Th-230, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 48,1)

D-34 ³ Th-230, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-04 ³ 1.000E-04 ³ RTF( 48,2)

D-34 ³ Th-230, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 5.000E-06 ³ 5.000E-06 ³ RTF( 48,3)

D-34 ³ ³ ³ ³ D-34 ³ U-233, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 49,1)

D-34 ³ U-233, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 49,2)

D-34 ³ U-233, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 49,3)

D-34 ³ ³ ³ ³ D-34 ³ U-234, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 50,1)

D-34 ³ U-234, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 50,2)

D-34 ³ U-234, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 50,3)

D-34 ³ ³ ³ ³ D-34 ³ U-235+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 51,1)

D-34 ³ U-235+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 51,2)

D-34 ³ U-235+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 51,3)

D-34 ³ ³ ³ ³ D-34 ³ U-238, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 52,1)

D-34 ³ U-238, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 52,2)

D-34 ³ U-238, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 52,3)

D-34 ³ ³ ³ ³ D-34 ³ U-238+D, plant/soil concentration ratio, dimensionless ³ 2.500E-03 ³ 2.500E-03 ³ RTF( 53,1)

D-34 ³ U-238+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 3.400E-04 ³ 3.400E-04 ³ RTF( 53,2)

D-34 ³ U-238+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-04 ³ 6.000E-04 ³ RTF( 53,3)

D-34 ³ ³ ³ ³ D-34 ³ Zn-65, plant/soil concentration ratio, dimensionless ³ 4.000E-01 ³ 4.000E-01 ³ RTF( 54,1)

D-34 ³ Zn-65, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-01 ³ 1.000E-01 ³ RTF( 54,2)

D-34 ³ Zn-65, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 1.000E-02 ³ 1.000E-02 ³ RTF( 54,3)

D-34 ³ ³ ³ ³ D-34 ³ Zr-95+D, plant/soil concentration ratio, dimensionless ³ 1.000E-03 ³ 1.000E-03 ³ RTF( 55,1)

D-34 ³ Zr-95+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 1.000E-06 ³ 1.000E-06 ³ RTF( 55,2)

D-34 ³ Zr-95+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 6.000E-07 ³ 6.000E-07 ³ RTF( 55,3)

³ ³ ³ ³ D-5 ³ Bioaccumulation factors, fresh water, L/kg: ³ ³ ³ D-5 ³ Ac-227+D, fish ³ 1.500E+01 ³ 1.500E+01 ³ BIOFAC( 1,1)

D-5 ³ Ac-227+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 1,2)

D-5 ³ ³ ³ ³ D-5 ³ Ag-110m+D, fish ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 2,1)

D-5 ³ Ag-110m+D, crustacea and mollusks ³ 7.700E+02 ³ 7.700E+02 ³ BIOFAC( 2,2)

D-5 ³ ³ ³ ³ D-5 ³ Am-241, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 3,1)

D-5 ³ Am-241, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 3,2)

D-5 ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 10 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Am-243+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 4,1)

D-5 ³ Am-243+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 4,2)

D-5 ³ ³ ³ ³ D-5 ³ C-14, fish ³ 5.000E+04 ³ 5.000E+04 ³ BIOFAC( 5,1)

D-5 ³ C-14, crustacea and mollusks ³ 9.100E+03 ³ 9.100E+03 ³ BIOFAC( 5,2)

D-5 ³ ³ ³ ³ D-5 ³ Ce-144+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 6,1)

D-5 ³ Ce-144+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 6,2)

D-5 ³ ³ ³ ³ D-5 ³ Cm-242, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 7,1)

D-5 ³ Cm-242, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 7,2)

D-5 ³ ³ ³ ³ D-5 ³ Cm-243, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 10,1)

D-5 ³ Cm-243, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 10,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-57, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 12,1)

D-5 ³ Co-57, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 12,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-58, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 13,1)

D-5 ³ Co-58, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 13,2)

D-5 ³ ³ ³ ³ D-5 ³ Co-60, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 14,1)

D-5 ³ Co-60, crustacea and mollusks ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 14,2)

D-5 ³ ³ ³ ³ D-5 ³ Cs-134, fish ³ 2.000E+03 ³ 2.000E+03 ³ BIOFAC( 15,1)

D-5 ³ Cs-134, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 15,2)

D-5 ³ ³ ³ ³ D-5 ³ Cs-137+D, fish ³ 2.000E+03 ³ 2.000E+03 ³ BIOFAC( 16,1)

D-5 ³ Cs-137+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 16,2)

D-5 ³ ³ ³ ³ D-5 ³ Eu-154, fish ³ 5.000E+01 ³ 5.000E+01 ³ BIOFAC( 17,1)

D-5 ³ Eu-154, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 17,2)

D-5 ³ ³ ³ ³ D-5 ³ Fe-55, fish ³ 2.000E+02 ³ 2.000E+02 ³ BIOFAC( 18,1)

D-5 ³ Fe-55, crustacea and mollusks ³ 3.200E+03 ³ 3.200E+03 ³ BIOFAC( 18,2)

D-5 ³ ³ ³ ³ D-5 ³ H-3, fish ³ 1.000E+00 ³ 1.000E+00 ³ BIOFAC( 19,1)

D-5 ³ H-3, crustacea and mollusks ³ 1.000E+00 ³ 1.000E+00 ³ BIOFAC( 19,2)

D-5 ³ ³ ³ ³ D-5 ³ I-129, fish ³ 4.000E+01 ³ 4.000E+01 ³ BIOFAC( 20,1)

D-5 ³ I-129, crustacea and mollusks ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 20,2)

D-5 ³ ³ ³ ³ D-5 ³ Mn-54, fish ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 21,1)

D-5 ³ Mn-54, crustacea and mollusks ³ 9.000E+04 ³ 9.000E+04 ³ BIOFAC( 21,2)

D-5 ³ ³ ³ ³ D-5 ³ Nb-94, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 22,1)

D-5 ³ Nb-94, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 22,2)

D-5 ³ ³ ³ ³ D-5 ³ Nb-95, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 23,1)

D-5 ³ Nb-95, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 23,2)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 11 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Ni-59, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 24,1)

D-5 ³ Ni-59, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 24,2)

D-5 ³ ³ ³ ³ D-5 ³ Ni-63, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 25,1)

D-5 ³ Ni-63, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 25,2)

D-5 ³ ³ ³ ³ D-5 ³ Np-237+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 26,1)

D-5 ³ Np-237+D, crustacea and mollusks ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 26,2)

D-5 ³ ³ ³ ³ D-5 ³ Pa-231, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 27,1)

D-5 ³ Pa-231, crustacea and mollusks ³ 1.100E+02 ³ 1.100E+02 ³ BIOFAC( 27,2)

D-5 ³ ³ ³ ³ D-5 ³ Pb-210+D, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 28,1)

D-5 ³ Pb-210+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 28,2)

D-5 ³ ³ ³ ³ D-5 ³ Po-210, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 29,1)

D-5 ³ Po-210, crustacea and mollusks ³ 2.000E+04 ³ 2.000E+04 ³ BIOFAC( 29,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-238, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 30,1)

D-5 ³ Pu-238, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 30,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-239, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 32,1)

D-5 ³ Pu-239, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 32,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-241, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 33,1)

D-5 ³ Pu-241, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 33,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-241+D, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 34,1)

D-5 ³ Pu-241+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 34,2)

D-5 ³ ³ ³ ³ D-5 ³ Pu-242, fish ³ 3.000E+01 ³ 3.000E+01 ³ BIOFAC( 35,1)

D-5 ³ Pu-242, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 35,2)

D-5 ³ ³ ³ ³ D-5 ³ Ra-226+D, fish ³ 5.000E+01 ³ 5.000E+01 ³ BIOFAC( 38,1)

D-5 ³ Ra-226+D, crustacea and mollusks ³ 2.500E+02 ³ 2.500E+02 ³ BIOFAC( 38,2)

D-5 ³ ³ ³ ³ D-5 ³ Ru-106+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 39,1)

D-5 ³ Ru-106+D, crustacea and mollusks ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 39,2)

D-5 ³ ³ ³ ³ D-5 ³ Sb-124, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 40,1)

D-5 ³ Sb-124, crustacea and mollusks ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 40,2)

D-5 ³ ³ ³ ³ D-5 ³ Sb-125, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 41,1)

D-5 ³ Sb-125, crustacea and mollusks ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 41,2)

D-5 ³ ³ ³ ³ D-5 ³ Sn-113+D, fish ³ 3.000E+03 ³ 3.000E+03 ³ BIOFAC( 43,1)

D-5 ³ Sn-113+D, crustacea and mollusks ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 43,2)

D-5 ³ ³ ³ ³ D-5 ³ Sr-90+D, fish ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 44,1)

D-5 ³ Sr-90+D, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 44,2)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 12 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 12 & FGR 11

³ ³ Current ³ Base ³ Parameter Menu ³ Parameter ³ Value# ³ Case* ³ Name

ÅÅÅÅ D-5 ³ Tc-99, fish ³ 2.000E+01 ³ 2.000E+01 ³ BIOFAC( 45,1)

D-5 ³ Tc-99, crustacea and mollusks ³ 5.000E+00 ³ 5.000E+00 ³ BIOFAC( 45,2)

D-5 ³ ³ ³ ³ D-5 ³ Te-125m, fish ³ 4.000E+02 ³ 4.000E+02 ³ BIOFAC( 46,1)

D-5 ³ Te-125m, crustacea and mollusks ³ 7.500E+01 ³ 7.500E+01 ³ BIOFAC( 46,2)

D-5 ³ ³ ³ ³ D-5 ³ Th-229+D, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 47,1)

D-5 ³ Th-229+D, crustacea and mollusks ³ 5.000E+02 ³ 5.000E+02 ³ BIOFAC( 47,2)

D-5 ³ ³ ³ ³ D-5 ³ Th-230, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 48,1)

D-5 ³ Th-230, crustacea and mollusks ³ 5.000E+02 ³ 5.000E+02 ³ BIOFAC( 48,2)

D-5 ³ ³ ³ ³ D-5 ³ U-233, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 49,1)

D-5 ³ U-233, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 49,2)

D-5 ³ ³ ³ ³ D-5 ³ U-234, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 50,1)

D-5 ³ U-234, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 50,2)

D-5 ³ ³ ³ ³ D-5 ³ U-235+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 51,1)

D-5 ³ U-235+D, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 51,2)

D-5 ³ ³ ³ ³ D-5 ³ U-238, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 52,1)

D-5 ³ U-238, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 52,2)

D-5 ³ ³ ³ ³ D-5 ³ U-238+D, fish ³ 1.000E+01 ³ 1.000E+01 ³ BIOFAC( 53,1)

D-5 ³ U-238+D, crustacea and mollusks ³ 6.000E+01 ³ 6.000E+01 ³ BIOFAC( 53,2)

D-5 ³ ³ ³ ³ D-5 ³ Zn-65, fish ³ 1.000E+03 ³ 1.000E+03 ³ BIOFAC( 54,1)

D-5 ³ Zn-65, crustacea and mollusks ³ 1.000E+04 ³ 1.000E+04 ³ BIOFAC( 54,2)

D-5 ³ ³ ³ ³ D-5 ³ Zr-95+D, fish ³ 3.000E+02 ³ 3.000E+02 ³ BIOFAC( 55,1)

D-5 ³ Zr-95+D, crustacea and mollusks ³ 6.700E+00 ³ 6.700E+00 ³ BIOFAC( 55,2)

  1. For DCF1(xxx) only, factors are for infinite depth & area. See ETFG table in Ground Pathway of Detailed Report.
  • Base Case means Default.Lib w/o Associate Nuclide contributions.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 13 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R011 ³ Area of contaminated zone (m**2) ³ 1.000E+04 ³ 1.000E+04 ³ --- ³ AREA R011 ³ Thickness of contaminated zone (m) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ THICK0 R011 ³ Fraction of contamination that is submerged ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ SUBMFRACT R011 ³ Length parallel to aquifer flow (m) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ LCZPAQ R011 ³ Basic radiation dose limit (mrem/yr) ³ 2.500E+01 ³ 3.000E+01 ³ --- ³ BRDL R011 ³ Time since placement of material (yr) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ TI R011 ³ Times for calculations (yr) ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ T( 2)

R011 ³ Times for calculations (yr) ³ 3.000E+00 ³ 3.000E+00 ³ --- ³ T( 3)

R011 ³ Times for calculations (yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ T( 4)

R011 ³ Times for calculations (yr) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ T( 5)

R011 ³ Times for calculations (yr) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ T( 6)

R011 ³ Times for calculations (yr) ³ 3.000E+02 ³ 3.000E+02 ³ --- ³ T( 7)

R011 ³ Times for calculations (yr) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ T( 8)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ --- ³ T( 9)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ --- ³ T(10)

³ ³ ³ ³ ³ R012 ³ Initial principal radionuclide (pCi/g): Ag-110m ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(2)

R012 ³ Initial principal radionuclide (pCi/g): Am-241 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(3)

R012 ³ Initial principal radionuclide (pCi/g): C-14 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(5)

R012 ³ Initial principal radionuclide (pCi/g): Ce-144 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(6)

R012 ³ Initial principal radionuclide (pCi/g): Cm-242 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(7)

R012 ³ Initial principal radionuclide (pCi/g): Cm-243 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(10)

R012 ³ Initial principal radionuclide (pCi/g): Co-57 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(12)

R012 ³ Initial principal radionuclide (pCi/g): Co-58 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(13)

R012 ³ Initial principal radionuclide (pCi/g): Co-60 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(14)

R012 ³ Initial principal radionuclide (pCi/g): Cs-134 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(15)

R012 ³ Initial principal radionuclide (pCi/g): Cs-137 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(16)

R012 ³ Initial principal radionuclide (pCi/g): Eu-154 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(17)

R012 ³ Initial principal radionuclide (pCi/g): Fe-55 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(18)

R012 ³ Initial principal radionuclide (pCi/g): H-3 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(19)

R012 ³ Initial principal radionuclide (pCi/g): I-129 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(20)

R012 ³ Initial principal radionuclide (pCi/g): Mn-54 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(21)

R012 ³ Initial principal radionuclide (pCi/g): Nb-94 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(22)

R012 ³ Initial principal radionuclide (pCi/g): Ni-59 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(24)

R012 ³ Initial principal radionuclide (pCi/g): Ni-63 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(25)

R012 ³ Initial principal radionuclide (pCi/g): Np-237 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(26)

R012 ³ Initial principal radionuclide (pCi/g): Pu-238 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(30)

R012 ³ Initial principal radionuclide (pCi/g): Pu-239 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(32)

R012 ³ Initial principal radionuclide (pCi/g): Pu-241 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(33)

R012 ³ Initial principal radionuclide (pCi/g): Pu-242 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(35)

R012 ³ Initial principal radionuclide (pCi/g): Ru-106 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(39)

R012 ³ Initial principal radionuclide (pCi/g): Sb-124 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(40)

R012 ³ Initial principal radionuclide (pCi/g): Sb-125 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(41)

R012 ³ Initial principal radionuclide (pCi/g): Sn-113 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(43)

R012 ³ Initial principal radionuclide (pCi/g): Sr-90 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(44)

R012 ³ Initial principal radionuclide (pCi/g): Tc-99 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(45)

R012 ³ Initial principal radionuclide (pCi/g): Zn-65 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(54)

R012 ³ Initial principal radionuclide (pCi/g): Zr-95 ³ 1.000E+00 ³ 0.000E+00 ³ --- ³ S1(55)

R012 ³ Concentration in groundwater (pCi/L): Ag-110m ³ not used ³ 0.000E+00 ³ --- ³ W1( 2)

R012 ³ Concentration in groundwater (pCi/L): Am-241 ³ not used ³ 0.000E+00 ³ --- ³ W1( 3)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 14 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R012 ³ Concentration in groundwater (pCi/L): C-14 ³ not used ³ 0.000E+00 ³ --- ³ W1( 5)

R012 ³ Concentration in groundwater (pCi/L): Ce-144 ³ not used ³ 0.000E+00 ³ --- ³ W1( 6)

R012 ³ Concentration in groundwater (pCi/L): Cm-242 ³ not used ³ 0.000E+00 ³ --- ³ W1( 7)

R012 ³ Concentration in groundwater (pCi/L): Cm-243 ³ not used ³ 0.000E+00 ³ --- ³ W1(10)

R012 ³ Concentration in groundwater (pCi/L): Co-57 ³ not used ³ 0.000E+00 ³ --- ³ W1(12)

R012 ³ Concentration in groundwater (pCi/L): Co-58 ³ not used ³ 0.000E+00 ³ --- ³ W1(13)

R012 ³ Concentration in groundwater (pCi/L): Co-60 ³ not used ³ 0.000E+00 ³ --- ³ W1(14)

R012 ³ Concentration in groundwater (pCi/L): Cs-134 ³ not used ³ 0.000E+00 ³ --- ³ W1(15)

R012 ³ Concentration in groundwater (pCi/L): Cs-137 ³ not used ³ 0.000E+00 ³ --- ³ W1(16)

R012 ³ Concentration in groundwater (pCi/L): Eu-154 ³ not used ³ 0.000E+00 ³ --- ³ W1(17)

R012 ³ Concentration in groundwater (pCi/L): Fe-55 ³ not used ³ 0.000E+00 ³ --- ³ W1(18)

R012 ³ Concentration in groundwater (pCi/L): H-3 ³ not used ³ 0.000E+00 ³ --- ³ W1(19)

R012 ³ Concentration in groundwater (pCi/L): I-129 ³ not used ³ 0.000E+00 ³ --- ³ W1(20)

R012 ³ Concentration in groundwater (pCi/L): Mn-54 ³ not used ³ 0.000E+00 ³ --- ³ W1(21)

R012 ³ Concentration in groundwater (pCi/L): Nb-94 ³ not used ³ 0.000E+00 ³ --- ³ W1(22)

R012 ³ Concentration in groundwater (pCi/L): Ni-59 ³ not used ³ 0.000E+00 ³ --- ³ W1(24)

R012 ³ Concentration in groundwater (pCi/L): Ni-63 ³ not used ³ 0.000E+00 ³ --- ³ W1(25)

R012 ³ Concentration in groundwater (pCi/L): Np-237 ³ not used ³ 0.000E+00 ³ --- ³ W1(26)

R012 ³ Concentration in groundwater (pCi/L): Pu-238 ³ not used ³ 0.000E+00 ³ --- ³ W1(30)

R012 ³ Concentration in groundwater (pCi/L): Pu-239 ³ not used ³ 0.000E+00 ³ --- ³ W1(32)

R012 ³ Concentration in groundwater (pCi/L): Pu-241 ³ not used ³ 0.000E+00 ³ --- ³ W1(33)

R012 ³ Concentration in groundwater (pCi/L): Pu-242 ³ not used ³ 0.000E+00 ³ --- ³ W1(35)

R012 ³ Concentration in groundwater (pCi/L): Ru-106 ³ not used ³ 0.000E+00 ³ --- ³ W1(39)

R012 ³ Concentration in groundwater (pCi/L): Sb-124 ³ not used ³ 0.000E+00 ³ --- ³ W1(40)

R012 ³ Concentration in groundwater (pCi/L): Sb-125 ³ not used ³ 0.000E+00 ³ --- ³ W1(41)

R012 ³ Concentration in groundwater (pCi/L): Sn-113 ³ not used ³ 0.000E+00 ³ --- ³ W1(43)

R012 ³ Concentration in groundwater (pCi/L): Sr-90 ³ not used ³ 0.000E+00 ³ --- ³ W1(44)

R012 ³ Concentration in groundwater (pCi/L): Tc-99 ³ not used ³ 0.000E+00 ³ --- ³ W1(45)

R012 ³ Concentration in groundwater (pCi/L): Zn-65 ³ not used ³ 0.000E+00 ³ --- ³ W1(54)

R012 ³ Concentration in groundwater (pCi/L): Zr-95 ³ not used ³ 0.000E+00 ³ --- ³ W1(55)

³ ³ ³ ³ ³ R013 ³ Cover depth (m) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ COVER0 R013 ³ Density of cover material (g/cm**3) ³ not used ³ 1.500E+00 ³ --- ³ DENSCV R013 ³ Cover depth erosion rate (m/yr) ³ not used ³ 1.000E-03 ³ --- ³ VCV R013 ³ Density of contaminated zone (g/cm**3) ³ 1.440E+00 ³ 1.500E+00 ³ --- ³ DENSCZ R013 ³ Contaminated zone erosion rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ --- ³ VCZ R013 ³ Contaminated zone total porosity ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ TPCZ R013 ³ Contaminated zone field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCCZ R013 ³ Contaminated zone hydraulic conductivity (m/yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ HCCZ R013 ³ Contaminated zone b parameter ³ 4.380E+00 ³ 5.300E+00 ³ --- ³ BCZ R013 ³ Average annual wind speed (m/sec) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ WIND R013 ³ Humidity in air (g/m**3) ³ 8.000E+00 ³ 8.000E+00 ³ --- ³ HUMID R013 ³ Evapotranspiration coefficient ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ EVAPTR R013 ³ Precipitation (m/yr) ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ PRECIP R013 ³ Irrigation (m/yr) ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ RI R013 ³ Irrigation mode ³ overhead ³ overhead ³ --- ³ IDITCH R013 ³ Runoff coefficient ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ RUNOFF R013 ³ Watershed area for nearby stream or pond (m**2) ³ 1.000E+06 ³ 1.000E+06 ³ --- ³ WAREA R013 ³ Accuracy for water/soil computations ³ 1.000E-03 ³ 1.000E-03 ³ Romberg failures occurred ³ EPS

³ ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 15 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R014 ³ Density of saturated zone (g/cm**3) ³ 1.500E+00 ³ 1.500E+00 ³ --- ³ DENSAQ R014 ³ Saturated zone total porosity ³ 3.400E-01 ³ 4.000E-01 ³ --- ³ TPSZ R014 ³ Saturated zone effective porosity ³ 2.700E-01 ³ 2.000E-01 ³ --- ³ EPSZ R014 ³ Saturated zone field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCSZ R014 ³ Saturated zone hydraulic conductivity (m/yr) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ HCSZ R014 ³ Saturated zone hydraulic gradient ³ 2.000E-02 ³ 2.000E-02 ³ --- ³ HGWT R014 ³ Saturated zone b parameter ³ 4.050E+00 ³ 5.300E+00 ³ --- ³ BSZ R014 ³ Water table drop rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ --- ³ VWT R014 ³ Well pump intake depth (m below water table) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DWIBWT R014 ³ Model: Nondispersion (ND) or Mass-Balance (MB) ³ ND ³ ND ³ --- ³ MODEL R014 ³ Well pumping rate (m**3/yr) ³ 2.500E+02 ³ 2.500E+02 ³ --- ³ UW

³ ³ ³ ³ ³ R015 ³ Number of unsaturated zone strata ³ 1 ³ 1 ³ --- ³ NS R015 ³ Unsat. zone 1, thickness (m) ³ 1.700E+00 ³ 4.000E+00 ³ --- ³ H(1)

R015 ³ Unsat. zone 1, soil density (g/cm**3) ³ 1.440E+00 ³ 1.500E+00 ³ --- ³ DENSUZ(1)

R015 ³ Unsat. zone 1, total porosity ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ TPUZ(1)

R015 ³ Unsat. zone 1, effective porosity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ EPUZ(1)

R015 ³ Unsat. zone 1, field capacity ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ FCUZ(1)

R015 ³ Unsat. zone 1, soil-specific b parameter ³ 4.380E+00 ³ 5.300E+00 ³ --- ³ BUZ(1)

R015 ³ Unsat. zone 1, hydraulic conductivity (m/yr) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ HCUZ(1)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ag-110m ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC( 2)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU( 2,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS( 2)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH( 2)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 2)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Am-241 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 3)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 3,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 3)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 3)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 3)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for C-14 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC( 5)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU( 5,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS( 5)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH( 5)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 5)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ce-144 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC( 6)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU( 6,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS( 6)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH( 6)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 6)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 16 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Cm-242 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCC( 7)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCU( 7,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCS( 7)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.260E-04 ³ ALEACH( 7)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 7)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cm-243 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCC(10)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCU(10,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 1.378E+03 ³ DCNUCS(10)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.260E-04 ³ ALEACH(10)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(10)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-57 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(12)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(12,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(12)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(12)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(12)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-58 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(13)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(13,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(13)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(13)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(13)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Co-60 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(14)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(14,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(14)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(14)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(14)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cs-134 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCC(15)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCU(15,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCS(15)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.774E-05 ³ ALEACH(15)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(15)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Cs-137 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCC(16)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCU(16,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.600E+03 ³ 4.600E+03 ³ --- ³ DCNUCS(16)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.774E-05 ³ ALEACH(16)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(16)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 17 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Eu-154 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCC(17)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCU(17,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 8.249E+02 ³ DCNUCS(17)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.104E-04 ³ ALEACH(17)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(17)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Fe-55 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(18)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(18,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(18)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(18)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(18)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for H-3 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(19)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(19,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(19)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(19)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(19)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for I-129 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCC(20)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCU(20,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E-01 ³ 1.000E-01 ³ --- ³ DCNUCS(20)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 5.506E-01 ³ ALEACH(20)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(20)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Mn-54 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCC(21)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCU(21,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+02 ³ 2.000E+02 ³ --- ³ DCNUCS(21)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.671E-04 ³ ALEACH(21)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(21)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Nb-94 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(22)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(22,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(22)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(22)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(22)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ni-59 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(24)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(24,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(24)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(24)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(24)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 18 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Ni-63 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCC(25)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCU(25,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+03 ³ 1.000E+03 ³ --- ³ DCNUCS(25)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.736E-04 ³ ALEACH(25)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(25)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Np-237 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCC(26)

R016 ³ Unsaturated zone 1 (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCU(26,1)

R016 ³ Saturated zone (cm**3/g) ³-1.000E+00 ³-1.000E+00 ³ 2.574E+02 ³ DCNUCS(26)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 6.739E-04 ³ ALEACH(26)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(26)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-238 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(30)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(30,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(30)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(30)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(30)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-239 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(32)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(32,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(32)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(32)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(32)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-241 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(33)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(33,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(33)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(33)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(33)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Pu-242 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCC(35)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCU(35,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+03 ³ 2.000E+03 ³ --- ³ DCNUCS(35)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.680E-05 ³ ALEACH(35)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(35)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Ru-106 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(39)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(39,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(39)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(39)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(39)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 19 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for Sb-124 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(40)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(40,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(40)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(40)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(40)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sb-125 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(41)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(41,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(41)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(41)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(41)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sn-113 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(43)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(43,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(43)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(43)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(43)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Sr-90 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCC(44)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCU(44,1)

R016 ³ Saturated zone (cm**3/g) ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ DCNUCS(44)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 5.746E-03 ³ ALEACH(44)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(44)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Tc-99 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(45)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(45,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(45)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(45)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(45)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Zn-65 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(54)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(54,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(54)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(54)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(54)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for Zr-95 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCC(55)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCU(55,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.200E+03 ³ 2.200E+03 ³ --- ³ DCNUCS(55)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 7.891E-05 ³ ALEACH(55)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(55)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 20 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for daughter Ac-227 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 1)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 1,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 1)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 1)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 1)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Am-243 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCC( 4)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCU( 4,1)

R016 ³ Saturated zone (cm**3/g) ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ DCNUCS( 4)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.588E-03 ³ ALEACH( 4)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK( 4)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Nb-95 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(23)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(23,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(23)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(23)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(23)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Pa-231 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(27)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(27,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(27)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(27)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(27)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Pb-210 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCC(28)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCU(28,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+02 ³ 1.000E+02 ³ --- ³ DCNUCS(28)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.732E-03 ³ ALEACH(28)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(28)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Po-210 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCC(29)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCU(29,1)

R016 ³ Saturated zone (cm**3/g) ³ 1.000E+01 ³ 1.000E+01 ³ --- ³ DCNUCS(29)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.700E-02 ³ ALEACH(29)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(29)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Ra-226 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCC(38)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCU(38,1)

R016 ³ Saturated zone (cm**3/g) ³ 7.000E+01 ³ 7.000E+01 ³ --- ³ DCNUCS(38)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.473E-03 ³ ALEACH(38)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(38)

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 21 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R016 ³ Distribution coefficients for daughter Te-125m ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCC(46)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCU(46,1)

R016 ³ Saturated zone (cm**3/g) ³ 0.000E+00 ³ 0.000E+00 ³ --- ³ DCNUCS(46)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 8.063E-01 ³ ALEACH(46)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(46)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Th-229 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCC(47)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCU(47,1)

R016 ³ Saturated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCS(47)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.894E-06 ³ ALEACH(47)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(47)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter Th-230 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCC(48)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCU(48,1)

R016 ³ Saturated zone (cm**3/g) ³ 6.000E+04 ³ 6.000E+04 ³ --- ³ DCNUCS(48)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 2.894E-06 ³ ALEACH(48)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(48)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-233 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(49)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(49,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(49)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(49)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(49)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-234 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(50)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(50,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(50)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(50)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(50)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-235 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(51)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(51,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(51)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(51)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(51)

³ ³ ³ ³ ³ R016 ³ Distribution coefficients for daughter U-238 ³ ³ ³ ³ R016 ³ Contaminated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCC(52)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCU(52,1)

R016 ³ Saturated zone (cm**3/g) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ DCNUCS(52)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 3.457E-03 ³ ALEACH(52)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used ³ SOLUBK(52)

R017 ³ Inhalation rate (m**3/yr) ³ 1.400E+04 ³ 8.400E+03 ³ --- ³ INHALR R017 ³ Mass loading for inhalation (g/m**3) ³ 1.000E-04 ³ 1.000E-04 ³ --- ³ MLINH R017 ³ Exposure duration ³ 3.000E+01 ³ 3.000E+01 ³ --- ³ ED R017 ³ Shielding factor, inhalation ³ 4.000E-01 ³ 4.000E-01 ³ --- ³ SHF3

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 22 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R017 ³ Shielding factor, external gamma ³ 7.000E-01 ³ 7.000E-01 ³ --- ³ SHF1 R017 ³ Fraction of time spent indoors ³ 0.000E+00 ³ 5.000E-01 ³ --- ³ FIND R017 ³ Fraction of time spent outdoors (on site) ³ 6.000E-03 ³ 2.500E-01 ³ --- ³ FOTD R017 ³ Shape factor flag, external gamma ³ 1.000E+00 ³ 1.000E+00 ³ >0 shows circular AREA. ³ FS R017 ³ Radii of shape factor array (used if FS = -1): ³ ³ ³ ³ R017 ³ Outer annular radius (m), ring 1: ³ not used ³ 5.000E+01 ³ --- ³ RAD_SHAPE( 1)

R017 ³ Outer annular radius (m), ring 2: ³ not used ³ 7.071E+01 ³ --- ³ RAD_SHAPE( 2)

R017 ³ Outer annular radius (m), ring 3: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 3)

R017 ³ Outer annular radius (m), ring 4: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 4)

R017 ³ Outer annular radius (m), ring 5: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 5)

R017 ³ Outer annular radius (m), ring 6: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 6)

R017 ³ Outer annular radius (m), ring 7: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 7)

R017 ³ Outer annular radius (m), ring 8: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 8)

R017 ³ Outer annular radius (m), ring 9: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE( 9)

R017 ³ Outer annular radius (m), ring 10: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(10)

R017 ³ Outer annular radius (m), ring 11: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(11)

R017 ³ Outer annular radius (m), ring 12: ³ not used ³ 0.000E+00 ³ --- ³ RAD_SHAPE(12)

³ ³ ³ ³ ³ R017 ³ Fractions of annular areas within AREA: ³ ³ ³ ³ R017 ³ Ring 1 ³ not used ³ 1.000E+00 ³ --- ³ FRACA( 1)

R017 ³ Ring 2 ³ not used ³ 2.732E-01 ³ --- ³ FRACA( 2)

R017 ³ Ring 3 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 3)

R017 ³ Ring 4 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 4)

R017 ³ Ring 5 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 5)

R017 ³ Ring 6 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 6)

R017 ³ Ring 7 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 7)

R017 ³ Ring 8 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 8)

R017 ³ Ring 9 ³ not used ³ 0.000E+00 ³ --- ³ FRACA( 9)

R017 ³ Ring 10 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(10)

R017 ³ Ring 11 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(11)

R017 ³ Ring 12 ³ not used ³ 0.000E+00 ³ --- ³ FRACA(12)

³ ³ ³ ³ ³ R018 ³ Fruits, vegetables and grain consumption (kg/yr) ³ not used ³ 1.600E+02 ³ --- ³ DIET(1)

R018 ³ Leafy vegetable consumption (kg/yr) ³ not used ³ 1.400E+01 ³ --- ³ DIET(2)

R018 ³ Milk consumption (L/yr) ³ not used ³ 9.200E+01 ³ --- ³ DIET(3)

R018 ³ Meat and poultry consumption (kg/yr) ³ 6.300E+01 ³ 6.300E+01 ³ --- ³ DIET(4)

R018 ³ Fish consumption (kg/yr) ³ 5.400E+00 ³ 5.400E+00 ³ --- ³ DIET(5)

R018 ³ Other seafood consumption (kg/yr) ³ 9.000E-01 ³ 9.000E-01 ³ --- ³ DIET(6)

R018 ³ Soil ingestion rate (g/yr) ³ 3.650E+01 ³ 3.650E+01 ³ --- ³ SOIL R018 ³ Drinking water intake (L/yr) ³ not used ³ 5.100E+02 ³ --- ³ DWI R018 ³ Contamination fraction of drinking water ³ not used ³ 1.000E+00 ³ --- ³ FDW R018 ³ Contamination fraction of household water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FHHW R018 ³ Contamination fraction of livestock water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FLW R018 ³ Contamination fraction of irrigation water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FIRW R018 ³ Contamination fraction of aquatic food ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ FR9 R018 ³ Contamination fraction of plant food ³ not used ³-1 ³ --- ³ FPLANT R018 ³ Contamination fraction of meat ³-1 ³-1 ³ 0.500E+00 ³ FMEAT R018 ³ Contamination fraction of milk ³ not used ³-1 ³ --- ³ FMILK

³ ³ ³ ³ ³ R019 ³ Livestock fodder intake for meat (kg/day) ³ 6.800E+01 ³ 6.800E+01 ³ --- ³ LFI5

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 23 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R019 ³ Livestock fodder intake for milk (kg/day) ³ not used ³ 5.500E+01 ³ --- ³ LFI6 R019 ³ Livestock water intake for meat (L/day) ³ 5.000E+01 ³ 5.000E+01 ³ --- ³ LWI5 R019 ³ Livestock water intake for milk (L/day) ³ not used ³ 1.600E+02 ³ --- ³ LWI6 R019 ³ Livestock soil intake (kg/day) ³ 5.000E-01 ³ 5.000E-01 ³ --- ³ LSI R019 ³ Mass loading for foliar deposition (g/m**3) ³ 1.000E-04 ³ 1.000E-04 ³ --- ³ MLFD R019 ³ Depth of soil mixing layer (m) ³ 1.500E-01 ³ 1.500E-01 ³ --- ³ DM R019 ³ Depth of roots (m) ³ 9.000E-01 ³ 9.000E-01 ³ --- ³ DROOT R019 ³ Drinking water fraction from ground water ³ not used ³ 1.000E+00 ³ --- ³ FGWDW R019 ³ Household water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWHH R019 ³ Livestock water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWLW R019 ³ Irrigation fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ FGWIR

³ ³ ³ ³ ³ R19B ³ Wet weight crop yield for Non-Leafy (kg/m**2) ³ not used ³ 7.000E-01 ³ --- ³ YV(1)

R19B ³ Wet weight crop yield for Leafy (kg/m**2) ³ not used ³ 1.500E+00 ³ --- ³ YV(2)

R19B ³ Wet weight crop yield for Fodder (kg/m**2) ³ 1.100E+00 ³ 1.100E+00 ³ --- ³ YV(3)

R19B ³ Growing Season for Non-Leafy (years) ³ not used ³ 1.700E-01 ³ --- ³ TE(1)

R19B ³ Growing Season for Leafy (years) ³ not used ³ 2.500E-01 ³ --- ³ TE(2)

R19B ³ Growing Season for Fodder (years) ³ 8.000E-02 ³ 8.000E-02 ³ --- ³ TE(3)

R19B ³ Translocation Factor for Non-Leafy ³ not used ³ 1.000E-01 ³ --- ³ TIV(1)

R19B ³ Translocation Factor for Leafy ³ not used ³ 1.000E+00 ³ --- ³ TIV(2)

R19B ³ Translocation Factor for Fodder ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ TIV(3)

R19B ³ Dry Foliar Interception Fraction for Non-Leafy ³ not used ³ 2.500E-01 ³ --- ³ RDRY(1)

R19B ³ Dry Foliar Interception Fraction for Leafy ³ not used ³ 2.500E-01 ³ --- ³ RDRY(2)

R19B ³ Dry Foliar Interception Fraction for Fodder ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RDRY(3)

R19B ³ Wet Foliar Interception Fraction for Non-Leafy ³ not used ³ 2.500E-01 ³ --- ³ RWET(1)

R19B ³ Wet Foliar Interception Fraction for Leafy ³ not used ³ 2.500E-01 ³ --- ³ RWET(2)

R19B ³ Wet Foliar Interception Fraction for Fodder ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ RWET(3)

R19B ³ Weathering Removal Constant for Vegetation ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ WLAM

³ ³ ³ ³ ³ C14 ³ C-12 concentration in water (g/cm**3) ³ 2.000E-05 ³ 2.000E-05 ³ --- ³ C12WTR C14 ³ C-12 concentration in contaminated soil (g/g) ³ 3.000E-02 ³ 3.000E-02 ³ --- ³ C12CZ C14 ³ Fraction of vegetation carbon from soil ³ 2.000E-02 ³ 2.000E-02 ³ --- ³ CSOIL C14 ³ Fraction of vegetation carbon from air ³ 9.800E-01 ³ 9.800E-01 ³ --- ³ CAIR C14 ³ C-14 evasion layer thickness in soil (m) ³ 3.000E-01 ³ 3.000E-01 ³ --- ³ DMC C14 ³ C-14 evasion flux rate from soil (1/sec) ³ 7.000E-07 ³ 7.000E-07 ³ --- ³ EVSN C14 ³ C-12 evasion flux rate from soil (1/sec) ³ 1.000E-10 ³ 1.000E-10 ³ --- ³ REVSN C14 ³ Fraction of grain in beef cattle feed ³ 8.000E-01 ³ 8.000E-01 ³ --- ³ AVFG4 C14 ³ Fraction of grain in milk cow feed ³ 2.000E-01 ³ 2.000E-01 ³ --- ³ AVFG5

³ ³ ³ ³ ³ STOR ³ Storage times of contaminated foodstuffs (days): ³ ³ ³ ³ STOR ³ Fruits, non-leafy vegetables, and grain ³ 1.400E+01 ³ 1.400E+01 ³ --- ³ STOR_T(1)

STOR ³ Leafy vegetables ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(2)

STOR ³ Milk ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(3)

STOR ³ Meat and poultry ³ 2.000E+01 ³ 2.000E+01 ³ --- ³ STOR_T(4)

STOR ³ Fish ³ 7.000E+00 ³ 7.000E+00 ³ --- ³ STOR_T(5)

STOR ³ Crustacea and mollusks ³ 7.000E+00 ³ 7.000E+00 ³ --- ³ STOR_T(6)

STOR ³ Well water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(7)

STOR ³ Surface water ³ 1.000E+00 ³ 1.000E+00 ³ --- ³ STOR_T(8)

STOR ³ Livestock fodder ³ 4.500E+01 ³ 4.500E+01 ³ --- ³ STOR_T(9)

³ ³ ³ ³ ³

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 24 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Site-Specific Parameter Summary (continued)

³ ³ User ³ ³ Used by RESRAD ³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅÅ R021 ³ Thickness of building foundation (m) ³ not used ³ 1.500E-01 ³ --- ³ FLOOR1 R021 ³ Bulk density of building foundation (g/cm**3) ³ not used ³ 2.400E+00 ³ --- ³ DENSFL R021 ³ Total porosity of the cover material ³ not used ³ 4.000E-01 ³ --- ³ TPCV R021 ³ Total porosity of the building foundation ³ not used ³ 1.000E-01 ³ --- ³ TPFL R021 ³ Volumetric water content of the cover material ³ not used ³ 5.000E-02 ³ --- ³ PH2OCV R021 ³ Volumetric water content of the foundation ³ not used ³ 3.000E-02 ³ --- ³ PH2OFL R021 ³ Diffusion coefficient for radon gas (m/sec): ³ ³ ³ ³ R021 ³ in cover material ³ not used ³ 2.000E-06 ³ --- ³ DIFCV R021 ³ in foundation material ³ not used ³ 3.000E-07 ³ --- ³ DIFFL R021 ³ in contaminated zone soil ³ 2.000E-06 ³ 2.000E-06 ³ --- ³ DIFCZ R021 ³ Radon vertical dimension of mixing (m) ³ 2.000E+00 ³ 2.000E+00 ³ --- ³ HMIX R021 ³ Average building air exchange rate (1/hr) ³ not used ³ 5.000E-01 ³ --- ³ REXG R021 ³ Height of the building (room) (m) ³ not used ³ 2.500E+00 ³ --- ³ HRM R021 ³ Building interior area factor ³ not used ³ 0.000E+00 ³ code computed (time dependent) ³ FAI R021 ³ Building depth below ground surface (m) ³ not used ³-1.000E+00 ³ code computed (time dependent) ³ DMFL R021 ³ Emanating power of Rn-222 gas ³ 2.500E-01 ³ 2.500E-01 ³ --- ³ EMANA(1)

R021 ³ Emanating power of Rn-220 gas ³ not used ³ 1.500E-01 ³ --- ³ EMANA(2)

³ ³ ³ ³ ³ TITL ³ Number of graphical time points ³ 32 ³ --- ³ --- ³ NPTS TITL ³ Maximum number of integration points for dose ³ 17 ³ --- ³ --- ³ LYMAX TITL ³ Maximum number of integration points for risk ³ 257 ³ --- ³ --- ³ KYMAX

Summary of Pathway Selections Pathway ³ User Selection

Å 1 -- external gamma ³ active 2 -- inhalation (w/o radon)³ active 3 -- plant ingestion ³ suppressed 4 -- meat ingestion ³ active 5 -- milk ingestion ³ suppressed 6 -- aquatic foods ³ active 7 -- drinking water ³ suppressed 8 -- soil ingestion ³ active 9 -- radon ³ active Find peak pathway doses ³ active

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 25 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 10000.00 square meters Ag-110m 1.000E+00 Thickness: 2.00 meters Am-241 1.000E+00 Cover Depth: 0.00 meters C-14 1.000E+00 Ce-144 1.000E+00 Cm-242 1.000E+00 Cm-243 1.000E+00 Co-57 1.000E+00 Co-58 1.000E+00 Co-60 1.000E+00 Cs-134 1.000E+00 Cs-137 1.000E+00 Eu-154 1.000E+00 Fe-55 1.000E+00 H-3 1.000E+00 I-129 1.000E+00 Mn-54 1.000E+00 Nb-94 1.000E+00 Ni-59 1.000E+00 Ni-63 1.000E+00 Np-237 1.000E+00 Pu-238 1.000E+00 Pu-239 1.000E+00 Pu-241 1.000E+00 Pu-242 1.000E+00 Ru-106 1.000E+00 Sb-124 1.000E+00 Sb-125 1.000E+00 Sn-113 1.000E+00 Sr-90 1.000E+00 Tc-99 1.000E+00 Zn-65 1.000E+00 Zr-95 1.000E+00 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.259E+00 5.630E+00 8.502E+00 4.079E+00 7.094E-01 3.985E-01 3.644E-01 1.515E-01 M(t): 1.303E-01 2.252E-01 3.401E-01 1.631E-01 2.837E-02 1.594E-02 1.458E-02 6.058E-03 Maximum TDOSE(t): 9.436E+00 mrem/yr at t = 5.05 n 0.01 years

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 26 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 5.051E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Nuclide Ag-110m 4.552E-06 0.0000 5.372E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.905E-07 0.0000 0.000E+00 0.0000 1.113E-10 0.0000 Am-241 2.406E-04 0.0000 5.967E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 3.081E-03 0.0003 0.000E+00 0.0000 7.533E-04 0.0001 C-14 1.619E-17 0.0000 1.527E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.826E-10 0.0000 0.000E+00 0.0000 9.362E-17 0.0000 Ce-144 1.353E-05 0.0000 3.918E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.236E-08 0.0000 0.000E+00 0.0000 3.406E-08 0.0000 Cm-242 4.585E-09 0.0000 2.727E-06 0.0000 8.551E-20 0.0000 0.000E+00 0.0000 2.798E-05 0.0000 0.000E+00 0.0000 3.427E-06 0.0000 Cm-243 2.908E-03 0.0003 3.813E-04 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.856E-04 0.0001 0.000E+00 0.0000 4.801E-04 0.0001 Co-57 1.663E-05 0.0000 7.465E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.556E-05 0.0000 0.000E+00 0.0000 1.496E-09 0.0000 Co-58 1.304E-10 0.0000 6.038E-17 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.221E-11 0.0000 0.000E+00 0.0000 3.054E-15 0.0000 Co-60 4.413E-02 0.0047 1.501E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.851E-02 0.0051 0.000E+00 0.0000 2.839E-06 0.0000 Cs-134 8.270E-03 0.0009 1.021E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.468E-02 0.0037 0.000E+00 0.0000 2.496E-06 0.0000 Cs-137 1.685E-02 0.0018 3.990E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.338E-01 0.0142 0.000E+00 0.0000 9.630E-06 0.0000 Eu-154 2.799E-02 0.0030 2.624E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.602E-04 0.0000 0.000E+00 0.0000 1.350E-06 0.0000 Fe-55 0.000E+00 0.0000 9.218E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.237E-05 0.0000 0.000E+00 0.0000 3.203E-08 0.0000 H-3 0.000E+00 0.0000 7.737E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.070E-07 0.0000 0.000E+00 0.0000 1.461E-12 0.0000 I-129 3.677E-06 0.0000 1.179E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.857E-03 0.0006 0.000E+00 0.0000 2.881E-06 0.0000 Mn-54 3.311E-04 0.0000 1.086E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.039E-05 0.0000 0.000E+00 0.0000 6.914E-09 0.0000 Nb-94 6.366E-04 0.0001 6.884E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.032E-09 0.0000 0.000E+00 0.0000 1.828E-08 0.0000 Ni-59 0.000E+00 0.0000 3.836E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.289E-04 0.0000 0.000E+00 0.0000 4.594E-08 0.0000 Ni-63 0.000E+00 0.0000 8.585E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.402E-04 0.0000 0.000E+00 0.0000 1.213E-07 0.0000 Np-237 6.219E-03 0.0007 7.651E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 2.595E-01 0.0275 0.000E+00 0.0000 9.695E-04 0.0001 Pu-238 8.590E-07 0.0000 5.333E-04 0.0001 2.318E-17 0.0000 0.000E+00 0.0000 5.480E-03 0.0006 0.000E+00 0.0000 6.704E-04 0.0001 Pu-239 1.688E-06 0.0000 6.097E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 6.333E-03 0.0007 0.000E+00 0.0000 7.748E-04 0.0001 Pu-241 2.013E-06 0.0000 1.376E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.186E-04 0.0000 0.000E+00 0.0000 1.751E-05 0.0000 Pu-242 7.541E-07 0.0000 5.842E-04 0.0001 5.076E-27 0.0000 0.000E+00 0.0000 6.012E-03 0.0006 0.000E+00 0.0000 7.355E-04 0.0001 Ru-106 1.994E-06 0.0000 1.862E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.363E-06 0.0000 0.000E+00 0.0000 1.647E-09 0.0000 Sb-124 1.327E-13 0.0000 7.218E-20 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.387E-16 0.0000 0.000E+00 0.0000 4.455E-18 0.0000 Sb-125 4.098E-05 0.0000 5.902E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.393E-05 0.0000 0.000E+00 0.0000 2.407E-09 0.0000 Sn-113 6.702E-10 0.0000 1.232E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.823E-11 0.0000 0.000E+00 0.0000 5.628E-14 0.0000 Sr-90 1.178E-04 0.0000 1.579E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.838E-01 0.0725 0.000E+00 0.0000 2.840E-05 0.0000 Tc-99 8.427E-09 0.0000 1.384E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.114E-05 0.0000 0.000E+00 0.0000 3.739E-09 0.0000 Zn-65 8.586E-07 0.0000 1.193E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.954E-05 0.0000 0.000E+00 0.0000 1.297E-10 0.0000 Zr-95 3.743E-11 0.0000 2.502E-17 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.221E-17 0.0000 0.000E+00 0.0000 9.484E-16 0.0000 Total 1.078E-01 0.0114 3.489E-03 0.0004 2.327E-17 0.0000 0.000E+00 0.0000 1.189E+00 0.1260 0.000E+00 0.0000 4.452E-03 0.0005

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 27 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 5.051E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Nuclide Ag-110m 0.000E+00 0.0000 1.529E-04 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.976E-04 0.0001 0.000E+00 0.0000 8.556E-04 0.0001 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.672E-03 0.0005 C-14 0.000E+00 0.0000 5.967E-01 0.0632 0.000E+00 0.0000 0.000E+00 0.0000 1.664E-02 0.0018 0.000E+00 0.0000 6.133E-01 0.0650 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.363E-05 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.414E-05 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.555E-03 0.0005 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.219E-05 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.826E-10 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.264E-02 0.0098 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.295E-02 0.0046 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.507E-01 0.0160 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.825E-02 0.0030 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.240E-05 0.0000 H-3 0.000E+00 0.0000 7.804E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.037E-04 0.0000 0.000E+00 0.0000 3.049E-04 0.0000 I-129 0.000E+00 0.0000 2.084E-01 0.0221 0.000E+00 0.0000 0.000E+00 0.0000 7.188E+00 0.7618 0.000E+00 0.0000 7.402E+00 0.7845 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.415E-04 0.0000 Nb-94 0.000E+00 0.0000 6.362E-02 0.0067 0.000E+00 0.0000 0.000E+00 0.0000 1.221E-05 0.0000 0.000E+00 0.0000 6.427E-02 0.0068 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.289E-04 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.403E-04 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.674E-01 0.0283 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.685E-03 0.0007 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.720E-03 0.0008 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.519E-04 0.0000 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.333E-03 0.0008 Ru-106 0.000E+00 0.0000 1.039E-03 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 7.010E-03 0.0007 0.000E+00 0.0000 8.052E-03 0.0009 Sb-124 0.000E+00 0.0000 4.048E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.012E-12 0.0000 0.000E+00 0.0000 1.219E-11 0.0000 Sb-125 0.000E+00 0.0000 4.440E-03 0.0005 0.000E+00 0.0000 0.000E+00 0.0000 1.138E-02 0.0012 0.000E+00 0.0000 1.588E-02 0.0017 Sn-113 0.000E+00 0.0000 1.720E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.097E-06 0.0000 0.000E+00 0.0000 2.818E-06 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.839E-01 0.0725 Tc-99 0.000E+00 0.0000 8.560E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 9.168E-04 0.0001 0.000E+00 0.0000 1.794E-03 0.0002 Zn-65 0.000E+00 0.0000 3.557E-03 0.0004 0.000E+00 0.0000 0.000E+00 0.0000 2.719E-02 0.0029 0.000E+00 0.0000 3.081E-02 0.0033 Zr-95 0.000E+00 0.0000 9.087E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.174E-16 0.0000 0.000E+00 0.0000 3.834E-11 0.0000 Total 0.000E+00 0.0000 8.788E-01 0.0931 0.000E+00 0.0000 0.000E+00 0.0000 7.252E+00 0.7686 0.000E+00 0.0000 9.436E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 28 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 4.456E-02 0.0137 5.259E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.571E-03 0.0017 0.000E+00 0.0000 1.089E-06 0.0000 Am-241 2.533E-04 0.0001 6.282E-04 0.0002 0.000E+00 0.0000 0.000E+00 0.0000 3.243E-03 0.0010 0.000E+00 0.0000 7.931E-04 0.0002 C-14 1.888E-08 0.0000 1.780E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.496E-01 0.0766 0.000E+00 0.0000 1.092E-07 0.0000 Ce-144 1.216E-03 0.0004 3.521E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.604E-06 0.0000 0.000E+00 0.0000 3.061E-06 0.0000 Cm-242 5.167E-07 0.0000 1.387E-05 0.0000 4.266E-23 0.0000 0.000E+00 0.0000 3.440E-05 0.0000 0.000E+00 0.0000 1.452E-05 0.0000 Cm-243 3.290E-03 0.0010 4.313E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 8.879E-04 0.0003 0.000E+00 0.0000 5.430E-04 0.0002 Co-57 1.867E-03 0.0006 8.380E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.869E-03 0.0009 0.000E+00 0.0000 1.679E-07 0.0000 Co-58 9.099E-03 0.0028 4.213E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.643E-03 0.0011 0.000E+00 0.0000 2.131E-07 0.0000 Co-60 8.581E-02 0.0263 2.918E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.433E-02 0.0289 0.000E+00 0.0000 5.520E-06 0.0000 Cs-134 4.518E-02 0.0139 5.580E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.894E-01 0.0581 0.000E+00 0.0000 1.363E-05 0.0000 Cs-137 1.894E-02 0.0058 4.484E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.504E-01 0.0462 0.000E+00 0.0000 1.082E-05 0.0000 Eu-154 4.171E-02 0.0128 3.911E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.878E-04 0.0001 0.000E+00 0.0000 2.011E-06 0.0000 Fe-55 0.000E+00 0.0000 3.374E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.917E-04 0.0001 0.000E+00 0.0000 1.172E-07 0.0000 H-3 0.000E+00 0.0000 3.606E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.769E-03 0.0005 0.000E+00 0.0000 6.812E-09 0.0000 I-129 5.933E-05 0.0000 1.903E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.316E-02 0.0286 0.000E+00 0.0000 4.648E-05 0.0000 Mn-54 1.990E-02 0.0061 6.527E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.247E-04 0.0002 0.000E+00 0.0000 4.156E-07 0.0000 Nb-94 3.737E-02 0.0115 4.041E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.939E-08 0.0000 0.000E+00 0.0000 1.073E-06 0.0000 Ni-59 0.000E+00 0.0000 3.839E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.290E-04 0.0000 0.000E+00 0.0000 4.599E-08 0.0000 Ni-63 0.000E+00 0.0000 8.912E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.532E-04 0.0001 0.000E+00 0.0000 1.259E-07 0.0000 Np-237 6.240E-03 0.0019 7.677E-04 0.0002 0.000E+00 0.0000 0.000E+00 0.0000 2.603E-01 0.0799 0.000E+00 0.0000 9.728E-04 0.0003 Pu-238 8.944E-07 0.0000 5.552E-04 0.0002 3.422E-20 0.0000 0.000E+00 0.0000 5.706E-03 0.0018 0.000E+00 0.0000 6.980E-04 0.0002 Pu-239 1.689E-06 0.0000 6.101E-04 0.0002 0.000E+00 0.0000 0.000E+00 0.0000 6.337E-03 0.0019 0.000E+00 0.0000 7.752E-04 0.0002 Pu-241 3.059E-07 0.0000 1.195E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.223E-04 0.0000 0.000E+00 0.0000 1.525E-05 0.0000 Pu-242 7.544E-07 0.0000 5.845E-04 0.0002 1.063E-30 0.0000 0.000E+00 0.0000 6.015E-03 0.0018 0.000E+00 0.0000 7.358E-04 0.0002 Ru-106 3.772E-03 0.0012 3.521E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.502E-03 0.0008 0.000E+00 0.0000 3.115E-06 0.0000 Sb-124 1.305E-02 0.0040 7.103E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.828E-05 0.0000 0.000E+00 0.0000 4.384E-07 0.0000 Sb-125 8.508E-03 0.0026 1.178E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.702E-03 0.0005 0.000E+00 0.0000 4.626E-07 0.0000 Sn-113 2.627E-03 0.0008 4.830E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.224E-04 0.0001 0.000E+00 0.0000 2.206E-07 0.0000 Sr-90 1.367E-04 0.0000 1.834E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.937E-01 0.2436 0.000E+00 0.0000 3.297E-05 0.0000 Tc-99 4.947E-07 0.0000 8.122E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.207E-03 0.0004 0.000E+00 0.0000 2.195E-07 0.0000 Zn-65 9.532E-03 0.0029 1.324E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.364E-01 0.1953 0.000E+00 0.0000 1.439E-06 0.0000 Zr-95 1.206E-02 0.0037 1.013E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.303E-08 0.0000 0.000E+00 0.0000 3.286E-07 0.0000 Total 3.652E-01 0.1121 3.612E-03 0.0011 3.426E-20 0.0000 0.000E+00 0.0000 2.511E+00 0.7706 0.000E+00 0.0000 4.672E-03 0.0014

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 29 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 1.309E-03 0.0004 0.000E+00 0.0000 0.000E+00 0.0000 3.156E-03 0.0010 0.000E+00 0.0000 5.459E-02 0.0168 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.918E-03 0.0015 C-14 0.000E+00 0.0000 1.509E-01 0.0463 0.000E+00 0.0000 0.000E+00 0.0000 2.708E-03 0.0008 0.000E+00 0.0000 4.032E-01 0.1237 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.225E-03 0.0004 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.331E-05 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.152E-03 0.0016 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.737E-03 0.0015 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.274E-02 0.0039 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.801E-01 0.0553 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.346E-01 0.0720 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.694E-01 0.0520 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.210E-02 0.0129 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.918E-04 0.0001 H-3 0.000E+00 0.0000 1.355E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.913E-05 0.0000 0.000E+00 0.0000 1.812E-03 0.0006 I-129 0.000E+00 0.0000 2.621E-03 0.0008 0.000E+00 0.0000 0.000E+00 0.0000 2.024E-02 0.0062 0.000E+00 0.0000 1.161E-01 0.0356 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.053E-02 0.0063 Nb-94 0.000E+00 0.0000 4.809E-03 0.0015 0.000E+00 0.0000 0.000E+00 0.0000 5.068E-07 0.0000 0.000E+00 0.0000 4.218E-02 0.0129 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.290E-04 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.533E-04 0.0001 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.683E-01 0.0823 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.960E-03 0.0021 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.724E-03 0.0024 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.499E-04 0.0000 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.336E-03 0.0023 Ru-106 0.000E+00 0.0000 1.962E-03 0.0006 0.000E+00 0.0000 0.000E+00 0.0000 7.085E-03 0.0022 0.000E+00 0.0000 1.532E-02 0.0047 Sb-124 0.000E+00 0.0000 6.999E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.284E-05 0.0000 0.000E+00 0.0000 1.327E-02 0.0041 Sb-125 0.000E+00 0.0000 1.065E-03 0.0003 0.000E+00 0.0000 0.000E+00 0.0000 1.480E-03 0.0005 0.000E+00 0.0000 1.275E-02 0.0039 Sn-113 0.000E+00 0.0000 3.447E-03 0.0011 0.000E+00 0.0000 0.000E+00 0.0000 1.103E-03 0.0003 0.000E+00 0.0000 7.400E-03 0.0023 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.939E-01 0.2436 Tc-99 0.000E+00 0.0000 6.469E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.728E-05 0.0000 0.000E+00 0.0000 1.310E-03 0.0004 Zn-65 0.000E+00 0.0000 3.420E-02 0.0105 0.000E+00 0.0000 0.000E+00 0.0000 1.378E-01 0.0423 0.000E+00 0.0000 8.180E-01 0.2510 Zr-95 0.000E+00 0.0000 5.842E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.457E-10 0.0000 0.000E+00 0.0000 1.206E-02 0.0037 Total 0.000E+00 0.0000 2.005E-01 0.0615 0.000E+00 0.0000 0.000E+00 0.0000 1.737E-01 0.0533 0.000E+00 0.0000 3.259E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 30 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 7.223E-03 0.0013 8.526E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.371E-04 0.0002 0.000E+00 0.0000 1.766E-07 0.0000 Am-241 2.507E-04 0.0000 6.218E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 3.211E-03 0.0006 0.000E+00 0.0000 7.851E-04 0.0001 C-14 3.046E-10 0.0000 2.872E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.303E-03 0.0009 0.000E+00 0.0000 1.761E-09 0.0000 Ce-144 4.991E-04 0.0001 1.445E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.300E-06 0.0000 0.000E+00 0.0000 1.256E-06 0.0000 Cm-242 1.127E-07 0.0000 5.142E-06 0.0000 1.072E-21 0.0000 0.000E+00 0.0000 2.996E-05 0.0000 0.000E+00 0.0000 5.850E-06 0.0000 Cm-243 3.210E-03 0.0006 4.209E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 8.666E-04 0.0002 0.000E+00 0.0000 5.299E-04 0.0001 Co-57 7.332E-04 0.0001 3.291E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.127E-03 0.0002 0.000E+00 0.0000 6.593E-08 0.0000 Co-58 2.546E-04 0.0000 1.179E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.020E-04 0.0000 0.000E+00 0.0000 5.964E-09 0.0000 Co-60 7.522E-02 0.0134 2.558E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.269E-02 0.0147 0.000E+00 0.0000 4.839E-06 0.0000 Cs-134 3.228E-02 0.0057 3.987E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.354E-01 0.0240 0.000E+00 0.0000 9.741E-06 0.0000 Cs-137 1.851E-02 0.0033 4.382E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.470E-01 0.0261 0.000E+00 0.0000 1.058E-05 0.0000 Eu-154 3.854E-02 0.0068 3.614E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.583E-04 0.0001 0.000E+00 0.0000 1.858E-06 0.0000 Fe-55 0.000E+00 0.0000 2.609E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.482E-04 0.0000 0.000E+00 0.0000 9.067E-08 0.0000 H-3 0.000E+00 0.0000 6.783E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.566E-04 0.0001 0.000E+00 0.0000 1.281E-09 0.0000 I-129 3.421E-05 0.0000 1.097E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.448E-02 0.0097 0.000E+00 0.0000 2.680E-05 0.0000 Mn-54 8.844E-03 0.0016 2.901E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.777E-04 0.0000 0.000E+00 0.0000 1.847E-07 0.0000 Nb-94 1.669E-02 0.0030 1.804E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.705E-08 0.0000 0.000E+00 0.0000 4.792E-07 0.0000 Ni-59 0.000E+00 0.0000 3.839E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.290E-04 0.0000 0.000E+00 0.0000 4.598E-08 0.0000 Ni-63 0.000E+00 0.0000 8.846E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.506E-04 0.0001 0.000E+00 0.0000 1.250E-07 0.0000 Np-237 6.236E-03 0.0011 7.672E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 2.602E-01 0.0462 0.000E+00 0.0000 9.722E-04 0.0002 Pu-238 8.873E-07 0.0000 5.508E-04 0.0001 5.116E-19 0.0000 0.000E+00 0.0000 5.661E-03 0.0010 0.000E+00 0.0000 6.925E-04 0.0001 Pu-239 1.689E-06 0.0000 6.100E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 6.336E-03 0.0011 0.000E+00 0.0000 7.751E-04 0.0001 Pu-241 6.860E-07 0.0000 1.237E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.217E-04 0.0000 0.000E+00 0.0000 1.577E-05 0.0000 Pu-242 7.544E-07 0.0000 5.844E-04 0.0001 3.289E-29 0.0000 0.000E+00 0.0000 6.014E-03 0.0011 0.000E+00 0.0000 7.357E-04 0.0001 Ru-106 8.467E-04 0.0002 7.905E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.789E-04 0.0001 0.000E+00 0.0000 6.993E-07 0.0000 Sb-124 8.692E-05 0.0000 4.730E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.496E-07 0.0000 0.000E+00 0.0000 2.919E-09 0.0000 Sb-125 2.959E-03 0.0005 4.260E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.956E-04 0.0002 0.000E+00 0.0000 1.736E-07 0.0000 Sn-113 1.300E-04 0.0000 2.391E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.129E-05 0.0000 0.000E+00 0.0000 1.092E-08 0.0000 Sr-90 1.327E-04 0.0000 1.780E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.707E-01 0.1369 0.000E+00 0.0000 3.201E-05 0.0000 Tc-99 2.209E-07 0.0000 3.626E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.540E-04 0.0001 0.000E+00 0.0000 9.800E-08 0.0000 Zn-65 1.507E-03 0.0003 2.094E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.045E-01 0.0186 0.000E+00 0.0000 2.276E-07 0.0000 Zr-95 3.403E-04 0.0001 2.282E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.664E-10 0.0000 0.000E+00 0.0000 8.629E-09 0.0000 Total 2.145E-01 0.0381 3.576E-03 0.0006 5.127E-19 0.0000 0.000E+00 0.0000 1.588E+00 0.2821 0.000E+00 0.0000 4.602E-03 0.0008

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 31 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 4.653E-03 0.0008 0.000E+00 0.0000 0.000E+00 0.0000 1.887E-02 0.0034 0.000E+00 0.0000 3.168E-02 0.0056 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.868E-03 0.0009 C-14 0.000E+00 0.0000 5.837E-01 0.1037 0.000E+00 0.0000 0.000E+00 0.0000 1.566E-02 0.0028 0.000E+00 0.0000 6.047E-01 0.1074 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.028E-04 0.0001 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.106E-05 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.028E-03 0.0009 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.860E-03 0.0003 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.566E-04 0.0001 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.579E-01 0.0280 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.676E-01 0.0298 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.655E-01 0.0294 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.890E-02 0.0069 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.483E-04 0.0000 H-3 0.000E+00 0.0000 7.499E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.787E-04 0.0000 0.000E+00 0.0000 6.368E-04 0.0001 I-129 0.000E+00 0.0000 7.076E-02 0.0126 0.000E+00 0.0000 0.000E+00 0.0000 2.067E+00 0.3672 0.000E+00 0.0000 2.192E+00 0.3894 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.122E-03 0.0016 Nb-94 0.000E+00 0.0000 3.409E-02 0.0061 0.000E+00 0.0000 0.000E+00 0.0000 5.891E-06 0.0000 0.000E+00 0.0000 5.078E-02 0.0090 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.290E-04 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.507E-04 0.0001 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.681E-01 0.0476 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.905E-03 0.0012 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.723E-03 0.0014 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.505E-04 0.0000 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.335E-03 0.0013 Ru-106 0.000E+00 0.0000 8.636E-03 0.0015 0.000E+00 0.0000 0.000E+00 0.0000 5.202E-02 0.0092 0.000E+00 0.0000 6.208E-02 0.0110 Sb-124 0.000E+00 0.0000 4.270E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.182E-05 0.0000 0.000E+00 0.0000 2.020E-04 0.0000 Sb-125 0.000E+00 0.0000 6.441E-03 0.0011 0.000E+00 0.0000 0.000E+00 0.0000 1.481E-02 0.0026 0.000E+00 0.0000 2.520E-02 0.0045 Sn-113 0.000E+00 0.0000 5.950E-03 0.0011 0.000E+00 0.0000 0.000E+00 0.0000 3.313E-03 0.0006 0.000E+00 0.0000 9.405E-03 0.0017 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.709E-01 0.1369 Tc-99 0.000E+00 0.0000 4.586E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 4.409E-04 0.0001 0.000E+00 0.0000 1.454E-03 0.0003 Zn-65 0.000E+00 0.0000 1.196E-01 0.0212 0.000E+00 0.0000 0.000E+00 0.0000 8.119E-01 0.1442 0.000E+00 0.0000 1.038E+00 0.1843 Zr-95 0.000E+00 0.0000 5.638E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.185E-10 0.0000 0.000E+00 0.0000 3.459E-04 0.0001 Total 0.000E+00 0.0000 8.343E-01 0.1482 0.000E+00 0.0000 0.000E+00 0.0000 2.984E+00 0.5301 0.000E+00 0.0000 5.630E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 32 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 1.899E-04 0.0000 2.241E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.463E-05 0.0000 0.000E+00 0.0000 4.641E-09 0.0000 Am-241 2.456E-04 0.0000 6.093E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 3.146E-03 0.0004 0.000E+00 0.0000 7.692E-04 0.0001 C-14 7.850E-14 0.0000 7.402E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.368E-06 0.0000 0.000E+00 0.0000 4.539E-13 0.0000 Ce-144 8.405E-05 0.0000 2.434E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.873E-07 0.0000 0.000E+00 0.0000 2.116E-07 0.0000 Cm-242 9.279E-09 0.0000 2.872E-06 0.0000 1.864E-20 0.0000 0.000E+00 0.0000 2.849E-05 0.0000 0.000E+00 0.0000 3.583E-06 0.0000 Cm-243 3.057E-03 0.0004 4.009E-04 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.256E-04 0.0001 0.000E+00 0.0000 5.047E-04 0.0001 Co-57 1.131E-04 0.0000 5.075E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.738E-04 0.0000 0.000E+00 0.0000 1.017E-08 0.0000 Co-58 1.994E-07 0.0000 9.236E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.987E-08 0.0000 0.000E+00 0.0000 4.671E-12 0.0000 Co-60 5.780E-02 0.0068 1.966E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.354E-02 0.0075 0.000E+00 0.0000 3.718E-06 0.0000 Cs-134 1.648E-02 0.0019 2.035E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.910E-02 0.0081 0.000E+00 0.0000 4.972E-06 0.0000 Cs-137 1.767E-02 0.0021 4.184E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.403E-01 0.0165 0.000E+00 0.0000 1.010E-05 0.0000 Eu-154 3.291E-02 0.0039 3.086E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.060E-04 0.0000 0.000E+00 0.0000 1.587E-06 0.0000 Fe-55 0.000E+00 0.0000 1.561E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.868E-05 0.0000 0.000E+00 0.0000 5.424E-08 0.0000 H-3 0.000E+00 0.0000 2.394E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.259E-05 0.0000 0.000E+00 0.0000 4.521E-11 0.0000 I-129 1.137E-05 0.0000 3.648E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.811E-02 0.0021 0.000E+00 0.0000 8.910E-06 0.0000 Mn-54 1.747E-03 0.0002 5.729E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.483E-05 0.0000 0.000E+00 0.0000 3.647E-08 0.0000 Nb-94 3.326E-03 0.0004 3.597E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.392E-09 0.0000 0.000E+00 0.0000 9.553E-08 0.0000 Ni-59 0.000E+00 0.0000 3.837E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.289E-04 0.0000 0.000E+00 0.0000 4.596E-08 0.0000 Ni-63 0.000E+00 0.0000 8.717E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.454E-04 0.0000 0.000E+00 0.0000 1.231E-07 0.0000 Np-237 6.227E-03 0.0007 7.661E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 2.598E-01 0.0306 0.000E+00 0.0000 9.709E-04 0.0001 Pu-238 8.732E-07 0.0000 5.421E-04 0.0001 5.927E-18 0.0000 0.000E+00 0.0000 5.571E-03 0.0007 0.000E+00 0.0000 6.815E-04 0.0001 Pu-239 1.689E-06 0.0000 6.098E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 6.335E-03 0.0007 0.000E+00 0.0000 7.749E-04 0.0001 Pu-241 1.382E-06 0.0000 1.311E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.202E-04 0.0000 0.000E+00 0.0000 1.669E-05 0.0000 Pu-242 7.542E-07 0.0000 5.843E-04 0.0001 8.254E-28 0.0000 0.000E+00 0.0000 6.013E-03 0.0007 0.000E+00 0.0000 7.356E-04 0.0001 Ru-106 4.267E-05 0.0000 3.984E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.918E-05 0.0000 0.000E+00 0.0000 3.524E-08 0.0000 Sb-124 3.854E-09 0.0000 2.097E-15 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.437E-11 0.0000 0.000E+00 0.0000 1.294E-13 0.0000 Sb-125 3.576E-04 0.0000 5.151E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.216E-04 0.0000 0.000E+00 0.0000 2.101E-08 0.0000 Sn-113 3.185E-07 0.0000 5.856E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.767E-08 0.0000 0.000E+00 0.0000 2.674E-11 0.0000 Sr-90 1.251E-04 0.0000 1.678E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.265E-01 0.0854 0.000E+00 0.0000 3.018E-05 0.0000 Tc-99 4.403E-08 0.0000 7.230E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.104E-04 0.0000 0.000E+00 0.0000 1.954E-08 0.0000 Zn-65 3.769E-05 0.0000 5.236E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.614E-03 0.0003 0.000E+00 0.0000 5.692E-09 0.0000 Zr-95 1.251E-07 0.0000 8.362E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.079E-13 0.0000 0.000E+00 0.0000 3.169E-12 0.0000 Total 1.404E-01 0.0165 3.531E-03 0.0004 5.946E-18 0.0000 0.000E+00 0.0000 1.303E+00 0.1533 0.000E+00 0.0000 4.517E-03 0.0005

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 33 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 1.121E-03 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 5.054E-03 0.0006 0.000E+00 0.0000 6.390E-03 0.0008 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.770E-03 0.0006 C-14 0.000E+00 0.0000 6.060E-01 0.0713 0.000E+00 0.0000 0.000E+00 0.0000 1.664E-02 0.0020 0.000E+00 0.0000 6.226E-01 0.0732 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.467E-05 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.495E-05 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.788E-03 0.0006 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.868E-04 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.793E-07 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.214E-01 0.0143 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.558E-02 0.0101 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.580E-01 0.0186 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.322E-02 0.0039 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.874E-05 0.0000 H-3 0.000E+00 0.0000 8.741E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.378E-04 0.0000 0.000E+00 0.0000 3.512E-04 0.0000 I-129 0.000E+00 0.0000 1.738E-01 0.0204 0.000E+00 0.0000 0.000E+00 0.0000 5.898E+00 0.6937 0.000E+00 0.0000 6.089E+00 0.7162 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.801E-03 0.0002 Nb-94 0.000E+00 0.0000 5.890E-02 0.0069 0.000E+00 0.0000 0.000E+00 0.0000 1.116E-05 0.0000 0.000E+00 0.0000 6.223E-02 0.0073 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.290E-04 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.455E-04 0.0000 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.678E-01 0.0315 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.795E-03 0.0008 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.721E-03 0.0009 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.514E-04 0.0000 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.334E-03 0.0009 Ru-106 0.000E+00 0.0000 3.918E-03 0.0005 0.000E+00 0.0000 0.000E+00 0.0000 2.611E-02 0.0031 0.000E+00 0.0000 3.010E-02 0.0035 Sb-124 0.000E+00 0.0000 2.034E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.977E-08 0.0000 0.000E+00 0.0000 6.398E-08 0.0000 Sb-125 0.000E+00 0.0000 6.852E-03 0.0008 0.000E+00 0.0000 0.000E+00 0.0000 1.734E-02 0.0020 0.000E+00 0.0000 2.467E-02 0.0029 Sn-113 0.000E+00 0.0000 1.427E-04 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.985E-05 0.0000 0.000E+00 0.0000 2.329E-04 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.266E-01 0.0855 Tc-99 0.000E+00 0.0000 7.924E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 8.373E-04 0.0001 0.000E+00 0.0000 1.740E-03 0.0002 Zn-65 0.000E+00 0.0000 2.745E-02 0.0032 0.000E+00 0.0000 0.000E+00 0.0000 2.073E-01 0.0244 0.000E+00 0.0000 2.374E-01 0.0279 Zr-95 0.000E+00 0.0000 3.039E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.925E-13 0.0000 0.000E+00 0.0000 1.281E-07 0.0000 Total 0.000E+00 0.0000 8.789E-01 0.1034 0.000E+00 0.0000 0.000E+00 0.0000 6.171E+00 0.7259 0.000E+00 0.0000 8.502E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 34 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 5.588E-10 0.0000 6.596E-16 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.250E-11 0.0000 0.000E+00 0.0000 1.366E-14 0.0000 Am-241 2.287E-04 0.0001 5.673E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 2.930E-03 0.0007 0.000E+00 0.0000 7.163E-04 0.0002 C-14 1.941E-26 0.0000 1.831E-24 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.398E-19 0.0000 0.000E+00 0.0000 1.122E-25 0.0000 Ce-144 1.647E-07 0.0000 4.770E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.592E-10 0.0000 0.000E+00 0.0000 4.147E-10 0.0000 Cm-242 4.216E-09 0.0000 2.617E-06 0.0000 6.533E-19 0.0000 0.000E+00 0.0000 2.690E-05 0.0000 0.000E+00 0.0000 3.290E-06 0.0000 Cm-243 2.576E-03 0.0006 3.379E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 6.969E-04 0.0002 0.000E+00 0.0000 4.255E-04 0.0001 Co-57 1.628E-07 0.0000 7.308E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.502E-07 0.0000 0.000E+00 0.0000 1.464E-11 0.0000 Co-58 2.682E-18 0.0000 1.242E-24 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.074E-18 0.0000 0.000E+00 0.0000 6.281E-23 0.0000 Co-60 2.300E-02 0.0056 7.821E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.528E-02 0.0062 0.000E+00 0.0000 1.479E-06 0.0000 Cs-134 1.566E-03 0.0004 1.934E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.568E-03 0.0016 0.000E+00 0.0000 4.726E-07 0.0000 Cs-137 1.503E-02 0.0037 3.558E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.193E-01 0.0293 0.000E+00 0.0000 8.588E-06 0.0000 Eu-154 1.893E-02 0.0046 1.775E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.760E-04 0.0000 0.000E+00 0.0000 9.129E-07 0.0000 Fe-55 0.000E+00 0.0000 2.585E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.468E-05 0.0000 0.000E+00 0.0000 8.982E-09 0.0000 H-3 0.000E+00 0.0000 1.926E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.014E-10 0.0000 0.000E+00 0.0000 3.638E-16 0.0000 I-129 2.410E-07 0.0000 7.730E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.838E-04 0.0001 0.000E+00 0.0000 1.888E-07 0.0000 Mn-54 5.979E-06 0.0000 1.961E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.877E-07 0.0000 0.000E+00 0.0000 1.249E-10 0.0000 Nb-94 1.176E-05 0.0000 1.272E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.907E-11 0.0000 0.000E+00 0.0000 3.379E-10 0.0000 Ni-59 0.000E+00 0.0000 3.832E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.288E-04 0.0000 0.000E+00 0.0000 4.590E-08 0.0000 Ni-63 0.000E+00 0.0000 8.277E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.280E-04 0.0001 0.000E+00 0.0000 1.169E-07 0.0000 Np-237 6.198E-03 0.0015 7.625E-04 0.0002 0.000E+00 0.0000 0.000E+00 0.0000 2.586E-01 0.0634 0.000E+00 0.0000 9.663E-04 0.0002 Pu-238 8.258E-07 0.0000 5.126E-04 0.0001 1.533E-16 0.0000 0.000E+00 0.0000 5.268E-03 0.0013 0.000E+00 0.0000 6.444E-04 0.0002 Pu-239 1.687E-06 0.0000 6.093E-04 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 6.330E-03 0.0016 0.000E+00 0.0000 7.743E-04 0.0002 Pu-241 3.240E-06 0.0000 1.495E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.146E-04 0.0000 0.000E+00 0.0000 1.897E-05 0.0000 Pu-242 7.538E-07 0.0000 5.839E-04 0.0001 6.361E-26 0.0000 0.000E+00 0.0000 6.010E-03 0.0015 0.000E+00 0.0000 7.352E-04 0.0002 Ru-106 1.226E-09 0.0000 1.145E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.384E-10 0.0000 0.000E+00 0.0000 1.013E-12 0.0000 Sb-124 2.237E-24 0.0000 1.217E-30 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.414E-26 0.0000 0.000E+00 0.0000 7.512E-29 0.0000 Sb-125 2.195E-07 0.0000 3.162E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.461E-08 0.0000 0.000E+00 0.0000 1.289E-11 0.0000 Sn-113 2.317E-16 0.0000 4.261E-22 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.013E-17 0.0000 0.000E+00 0.0000 1.946E-20 0.0000 Sr-90 1.017E-04 0.0000 1.364E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.907E-01 0.1448 0.000E+00 0.0000 2.454E-05 0.0000 Tc-99 1.558E-10 0.0000 2.557E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.907E-07 0.0000 0.000E+00 0.0000 6.911E-11 0.0000 Zn-65 9.317E-11 0.0000 1.294E-16 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.461E-09 0.0000 0.000E+00 0.0000 1.407E-14 0.0000 Zr-95 1.168E-19 0.0000 7.805E-26 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.941E-25 0.0000 0.000E+00 0.0000 2.958E-24 0.0000 Total 6.765E-02 0.0166 3.393E-03 0.0008 1.539E-16 0.0000 0.000E+00 0.0000 1.023E+00 0.2508 0.000E+00 0.0000 4.321E-03 0.0011

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 35 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 2.859E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.445E-07 0.0000 0.000E+00 0.0000 1.738E-07 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.443E-03 0.0011 C-14 0.000E+00 0.0000 7.830E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.462E-10 0.0000 0.000E+00 0.0000 8.177E-09 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.660E-07 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.281E-05 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.037E-03 0.0010 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.130E-07 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.756E-18 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.828E-02 0.0118 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.135E-03 0.0020 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.344E-01 0.0329 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.911E-02 0.0047 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.469E-05 0.0000 H-3 0.000E+00 0.0000 4.268E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.855E-07 0.0000 0.000E+00 0.0000 1.861E-07 0.0000 I-129 0.000E+00 0.0000 7.799E-02 0.0191 0.000E+00 0.0000 0.000E+00 0.0000 2.901E+00 0.7111 0.000E+00 0.0000 2.979E+00 0.7304 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.167E-06 0.0000 Nb-94 0.000E+00 0.0000 1.679E-03 0.0004 0.000E+00 0.0000 0.000E+00 0.0000 3.565E-07 0.0000 0.000E+00 0.0000 1.691E-03 0.0004 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.288E-04 0.0000 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.281E-04 0.0001 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.665E-01 0.0653 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.426E-03 0.0016 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.715E-03 0.0019 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.518E-04 0.0000 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.329E-03 0.0018 Ru-106 0.000E+00 0.0000 9.536E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.125E-06 0.0000 0.000E+00 0.0000 8.081E-06 0.0000 Sb-124 0.000E+00 0.0000 1.204E-22 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.642E-22 0.0000 0.000E+00 0.0000 3.868E-22 0.0000 Sb-125 0.000E+00 0.0000 3.452E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.793E-05 0.0000 0.000E+00 0.0000 1.327E-04 0.0000 Sn-113 0.000E+00 0.0000 9.681E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.841E-13 0.0000 0.000E+00 0.0000 1.652E-12 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.909E-01 0.1449 Tc-99 0.000E+00 0.0000 2.259E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.683E-05 0.0000 0.000E+00 0.0000 4.981E-05 0.0000 Zn-65 0.000E+00 0.0000 5.891E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.989E-06 0.0000 0.000E+00 0.0000 5.584E-06 0.0000 Zr-95 0.000E+00 0.0000 2.820E-21 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.642E-25 0.0000 0.000E+00 0.0000 1.196E-19 0.0000 Total 0.000E+00 0.0000 7.973E-02 0.0195 0.000E+00 0.0000 0.000E+00 0.0000 2.901E+00 0.7112 0.000E+00 0.0000 4.079E+00 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 36 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 8.790E-26 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.140E-26 0.0000 0.000E+00 0.0000 2.149E-30 0.0000 Am-241 1.866E-04 0.0003 4.627E-04 0.0007 0.000E+00 0.0000 0.000E+00 0.0000 2.391E-03 0.0034 0.000E+00 0.0000 5.842E-04 0.0008 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 3.023E-15 0.0000 8.753E-19 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.393E-17 0.0000 0.000E+00 0.0000 7.610E-18 0.0000 Cm-242 3.594E-09 0.0000 2.231E-06 0.0000 1.667E-17 0.0000 0.000E+00 0.0000 2.293E-05 0.0000 0.000E+00 0.0000 2.805E-06 0.0000 Cm-243 1.580E-03 0.0022 2.075E-04 0.0003 0.000E+00 0.0000 0.000E+00 0.0000 4.303E-04 0.0006 0.000E+00 0.0000 2.613E-04 0.0004 Co-57 1.238E-15 0.0000 5.556E-21 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.902E-15 0.0000 0.000E+00 0.0000 1.113E-19 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 1.652E-03 0.0023 5.617E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.816E-03 0.0026 0.000E+00 0.0000 1.063E-07 0.0000 Cs-134 1.883E-06 0.0000 2.325E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.894E-06 0.0000 0.000E+00 0.0000 5.681E-10 0.0000 Cs-137 9.460E-03 0.0133 2.240E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.512E-02 0.1059 0.000E+00 0.0000 5.406E-06 0.0000 Eu-154 3.902E-03 0.0055 3.658E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.628E-05 0.0001 0.000E+00 0.0000 1.881E-07 0.0000 Fe-55 0.000E+00 0.0000 1.517E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.620E-08 0.0000 0.000E+00 0.0000 5.272E-11 0.0000 H-3 0.000E+00 0.0000 4.291E-28 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.265E-25 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 3.977E-12 0.0000 1.275E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.333E-09 0.0000 0.000E+00 0.0000 3.116E-12 0.0000 Mn-54 5.398E-13 0.0000 1.771E-19 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.695E-14 0.0000 0.000E+00 0.0000 1.127E-17 0.0000 Nb-94 1.166E-12 0.0000 1.261E-17 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.890E-18 0.0000 0.000E+00 0.0000 3.348E-17 0.0000 Ni-59 0.000E+00 0.0000 3.818E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.283E-04 0.0002 0.000E+00 0.0000 4.573E-08 0.0000 Ni-63 0.000E+00 0.0000 7.139E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.829E-04 0.0004 0.000E+00 0.0000 1.009E-07 0.0000 Np-237 6.115E-03 0.0086 7.523E-04 0.0011 0.000E+00 0.0000 0.000E+00 0.0000 2.551E-01 0.3596 0.000E+00 0.0000 9.534E-04 0.0013 Pu-238 7.040E-07 0.0000 4.370E-04 0.0006 3.487E-15 0.0000 0.000E+00 0.0000 4.490E-03 0.0063 0.000E+00 0.0000 5.493E-04 0.0008 Pu-239 1.683E-06 0.0000 6.079E-04 0.0009 0.000E+00 0.0000 0.000E+00 0.0000 6.315E-03 0.0089 0.000E+00 0.0000 7.725E-04 0.0011 Pu-241 5.426E-06 0.0000 1.609E-05 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.740E-05 0.0001 0.000E+00 0.0000 2.035E-05 0.0000 Pu-242 7.524E-07 0.0000 5.829E-04 0.0008 4.330E-24 0.0000 0.000E+00 0.0000 5.999E-03 0.0085 0.000E+00 0.0000 7.339E-04 0.0010 Ru-106 1.296E-22 0.0000 1.210E-26 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.859E-23 0.0000 0.000E+00 0.0000 1.070E-25 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 1.460E-16 0.0000 2.103E-22 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.961E-17 0.0000 0.000E+00 0.0000 8.574E-21 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 5.634E-05 0.0001 7.556E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.271E-01 0.4612 0.000E+00 0.0000 1.359E-05 0.0000 Tc-99 1.544E-17 0.0000 2.536E-19 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.873E-14 0.0000 0.000E+00 0.0000 6.852E-18 0.0000 Zn-65 8.903E-27 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.174E-25 0.0000 0.000E+00 0.0000 1.345E-30 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 2.296E-02 0.0324 3.070E-03 0.0043 3.503E-15 0.0000 0.000E+00 0.0000 6.794E-01 0.9577 0.000E+00 0.0000 3.897E-03 0.0055

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 37 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 4.477E-24 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.263E-23 0.0000 0.000E+00 0.0000 2.721E-23 0.0000 Am-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.625E-03 0.0051 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.045E-15 0.0000 Cm-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.797E-05 0.0000 Cm-243 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.479E-03 0.0035 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.141E-15 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.468E-03 0.0049 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.777E-06 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.459E-02 0.1192 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.938E-03 0.0056 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.625E-08 0.0000 H-3 0.000E+00 0.0000 1.046E-24 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.552E-22 0.0000 0.000E+00 0.0000 4.564E-22 0.0000 I-129 0.000E+00 0.0000 1.282E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.768E-05 0.0001 0.000E+00 0.0000 4.897E-05 0.0001 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.568E-13 0.0000 Nb-94 0.000E+00 0.0000 1.656E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.516E-14 0.0000 0.000E+00 0.0000 1.668E-10 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.283E-04 0.0002 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.830E-04 0.0004 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.629E-01 0.3707 Pu-238 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.477E-03 0.0077 Pu-239 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.697E-03 0.0109 Pu-241 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.393E-04 0.0002 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.317E-03 0.0103 Ru-106 0.000E+00 0.0000 1.003E-19 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.495E-19 0.0000 0.000E+00 0.0000 8.500E-19 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 2.285E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.482E-14 0.0000 0.000E+00 0.0000 8.786E-14 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.272E-01 0.4613 Tc-99 0.000E+00 0.0000 2.230E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.648E-12 0.0000 0.000E+00 0.0000 4.916E-12 0.0000 Zn-65 0.000E+00 0.0000 5.602E-23 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.744E-22 0.0000 0.000E+00 0.0000 5.311E-22 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 1.282E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.768E-05 0.0001 0.000E+00 0.0000 7.094E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 38 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 9.152E-05 0.0002 2.267E-04 0.0006 0.000E+00 0.0000 0.000E+00 0.0000 1.176E-03 0.0030 0.000E+00 0.0000 2.862E-04 0.0007 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 2.057E-09 0.0000 1.276E-06 0.0000 4.836E-16 0.0000 0.000E+00 0.0000 1.311E-05 0.0000 0.000E+00 0.0000 1.604E-06 0.0000 Cm-243 2.854E-04 0.0007 3.807E-05 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 8.379E-05 0.0002 0.000E+00 0.0000 4.794E-05 0.0001 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 1.640E-07 0.0000 5.578E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.803E-07 0.0000 0.000E+00 0.0000 1.055E-11 0.0000 Cs-134 1.133E-16 0.0000 1.400E-22 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.752E-16 0.0000 0.000E+00 0.0000 3.420E-20 0.0000 Cs-137 1.872E-03 0.0047 4.432E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.487E-02 0.0373 0.000E+00 0.0000 1.070E-06 0.0000 Eu-154 1.550E-05 0.0000 1.453E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.441E-07 0.0000 0.000E+00 0.0000 7.473E-10 0.0000 Fe-55 0.000E+00 0.0000 2.351E-20 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.336E-15 0.0000 0.000E+00 0.0000 8.170E-19 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 7.259E-29 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.156E-25 0.0000 0.000E+00 0.0000 5.687E-29 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 3.770E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.267E-04 0.0003 0.000E+00 0.0000 4.515E-08 0.0000 Ni-63 0.000E+00 0.0000 4.255E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.686E-04 0.0004 0.000E+00 0.0000 6.010E-08 0.0000 Np-237 5.833E-03 0.0146 7.177E-04 0.0018 0.000E+00 0.0000 0.000E+00 0.0000 2.434E-01 0.6107 0.000E+00 0.0000 9.094E-04 0.0023 Pu-238 4.029E-07 0.0000 2.498E-04 0.0006 9.684E-14 0.0000 0.000E+00 0.0000 2.568E-03 0.0064 0.000E+00 0.0000 3.141E-04 0.0008 Pu-239 1.670E-06 0.0000 6.030E-04 0.0015 0.000E+00 0.0000 0.000E+00 0.0000 6.264E-03 0.0157 0.000E+00 0.0000 7.663E-04 0.0019 Pu-241 3.774E-06 0.0000 9.444E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.939E-05 0.0001 0.000E+00 0.0000 1.192E-05 0.0000 Pu-242 7.478E-07 0.0000 5.793E-04 0.0015 4.409E-22 0.0000 0.000E+00 0.0000 5.962E-03 0.0150 0.000E+00 0.0000 7.293E-04 0.0018 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 7.120E-06 0.0000 9.550E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.134E-02 0.1038 0.000E+00 0.0000 1.717E-06 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 8.112E-03 0.0204 2.426E-03 0.0061 9.732E-14 0.0000 0.000E+00 0.0000 3.160E-01 0.7929 0.000E+00 0.0000 3.070E-03 0.0077

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 39 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 0.000E+00 0.0000 6.368E-02 0.1598 0.000E+00 0.0000 0.000E+00 0.0000 3.267E-03 0.0082 0.000E+00 0.0000 6.872E-02 0.1725 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 0.000E+00 0.0000 5.721E-25 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.272E-25 0.0000 0.000E+00 0.0000 1.599E-05 0.0000 Cm-243 0.000E+00 0.0000 2.899E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.485E-08 0.0000 0.000E+00 0.0000 4.555E-04 0.0011 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.444E-07 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.886E-16 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.674E-02 0.0420 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.564E-05 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.337E-15 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 2.308E-23 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.583E-22 0.0000 0.000E+00 0.0000 8.815E-22 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.267E-04 0.0003 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.687E-04 0.0004 Np-237 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.508E-01 0.6294 Pu-238 0.000E+00 0.0000 1.405E-22 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.126E-23 0.0000 0.000E+00 0.0000 3.132E-03 0.0079 Pu-239 0.000E+00 0.0000 3.998E-13 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.773E-15 0.0000 0.000E+00 0.0000 7.635E-03 0.0192 Pu-241 0.000E+00 0.0000 1.353E-03 0.0034 0.000E+00 0.0000 0.000E+00 0.0000 6.934E-05 0.0002 0.000E+00 0.0000 1.497E-03 0.0038 Pu-242 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.271E-03 0.0182 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 2.416E-05 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 5.099E-04 0.0013 0.000E+00 0.0000 4.189E-02 0.1051 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 6.506E-02 0.1633 0.000E+00 0.0000 0.000E+00 0.0000 3.846E-03 0.0097 0.000E+00 0.0000 3.985E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 40 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 1.207E-05 0.0000 2.955E-05 0.0001 0.000E+00 0.0000 0.000E+00 0.0000 1.593E-04 0.0004 0.000E+00 0.0000 3.730E-05 0.0001 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 4.237E-10 0.0000 2.584E-07 0.0000 6.662E-15 0.0000 0.000E+00 0.0000 2.655E-06 0.0000 0.000E+00 0.0000 3.246E-07 0.0000 Cm-243 2.155E-06 0.0000 9.777E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.807E-06 0.0000 0.000E+00 0.0000 1.239E-06 0.0000 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 5.994E-19 0.0000 2.038E-24 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.589E-19 0.0000 0.000E+00 0.0000 3.856E-23 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 1.829E-05 0.0001 4.330E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.452E-04 0.0004 0.000E+00 0.0000 1.045E-08 0.0000 Eu-154 2.140E-12 0.0000 2.007E-17 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.990E-14 0.0000 0.000E+00 0.0000 1.032E-16 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 3.634E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.221E-04 0.0003 0.000E+00 0.0000 4.353E-08 0.0000 Ni-63 0.000E+00 0.0000 9.697E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.843E-05 0.0001 0.000E+00 0.0000 1.370E-08 0.0000 Np-237 5.097E-03 0.0140 6.273E-04 0.0017 0.000E+00 0.0000 0.000E+00 0.0000 2.127E-01 0.5836 0.000E+00 0.0000 7.947E-04 0.0022 Pu-238 8.299E-08 0.0000 5.060E-05 0.0001 1.317E-12 0.0000 0.000E+00 0.0000 5.200E-04 0.0014 0.000E+00 0.0000 6.358E-05 0.0002 Pu-239 1.632E-06 0.0000 5.893E-04 0.0016 0.000E+00 0.0000 0.000E+00 0.0000 6.121E-03 0.0168 0.000E+00 0.0000 7.488E-04 0.0021 Pu-241 5.074E-07 0.0000 1.246E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.656E-06 0.0000 0.000E+00 0.0000 1.573E-06 0.0000 Pu-242 7.347E-07 0.0000 5.691E-04 0.0016 2.363E-20 0.0000 0.000E+00 0.0000 5.857E-03 0.0161 0.000E+00 0.0000 7.165E-04 0.0020 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 1.931E-08 0.0000 2.591E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.122E-04 0.0003 0.000E+00 0.0000 4.659E-09 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 5.133E-03 0.0141 1.868E-03 0.0051 1.324E-12 0.0000 0.000E+00 0.0000 2.258E-01 0.6196 0.000E+00 0.0000 2.364E-03 0.0065

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 41 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 0.000E+00 0.0000 1.190E-01 0.3265 0.000E+00 0.0000 0.000E+00 0.0000 6.117E-03 0.0168 0.000E+00 0.0000 1.253E-01 0.3440 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 0.000E+00 0.0000 2.358E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 7.376E-10 0.0000 0.000E+00 0.0000 3.240E-06 0.0000 Cm-243 0.000E+00 0.0000 1.575E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.095E-08 0.0000 0.000E+00 0.0000 1.383E-05 0.0000 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.258E-18 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.635E-04 0.0004 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.160E-12 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.222E-04 0.0003 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.844E-05 0.0001 Np-237 0.000E+00 0.0000 1.160E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.980E-07 0.0000 0.000E+00 0.0000 2.192E-01 0.6015 Pu-238 0.000E+00 0.0000 4.676E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.461E-07 0.0000 0.000E+00 0.0000 6.345E-04 0.0017 Pu-239 0.000E+00 0.0000 1.877E-10 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.822E-10 0.0000 0.000E+00 0.0000 7.461E-03 0.0205 Pu-241 0.000E+00 0.0000 3.930E-03 0.0108 0.000E+00 0.0000 0.000E+00 0.0000 2.020E-04 0.0006 0.000E+00 0.0000 4.142E-03 0.0114 Pu-242 0.000E+00 0.0000 3.222E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.083E-11 0.0000 0.000E+00 0.0000 7.143E-03 0.0196 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 1.313E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.788E-05 0.0001 0.000E+00 0.0000 1.414E-04 0.0004 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 1.229E-01 0.3373 0.000E+00 0.0000 0.000E+00 0.0000 6.348E-03 0.0174 0.000E+00 0.0000 3.644E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 42 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 1.177E-07 0.0000 3.686E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.636E-06 0.0000 0.000E+00 0.0000 4.659E-08 0.0000 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 3.492E-11 0.0000 9.843E-10 0.0000 3.114E-14 0.0000 0.000E+00 0.0000 1.035E-08 0.0000 0.000E+00 0.0000 1.219E-09 0.0000 Cm-243 1.791E-09 0.0000 6.418E-07 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 6.667E-06 0.0000 0.000E+00 0.0000 8.156E-07 0.0000 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 1.685E-12 0.0000 3.990E-18 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.338E-11 0.0000 0.000E+00 0.0000 9.631E-16 0.0000 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 3.198E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.074E-04 0.0007 0.000E+00 0.0000 3.830E-08 0.0000 Ni-63 0.000E+00 0.0000 5.481E-12 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.172E-07 0.0000 0.000E+00 0.0000 7.743E-11 0.0000 Np-237 3.180E-03 0.0210 3.915E-04 0.0026 0.000E+00 0.0000 0.000E+00 0.0000 1.327E-01 0.8760 0.000E+00 0.0000 4.958E-04 0.0033 Pu-238 6.876E-09 0.0000 1.928E-07 0.0000 6.133E-12 0.0000 0.000E+00 0.0000 2.027E-06 0.0000 0.000E+00 0.0000 2.388E-07 0.0000 Pu-239 1.506E-06 0.0000 5.435E-04 0.0036 0.000E+00 0.0000 0.000E+00 0.0000 5.645E-03 0.0373 0.000E+00 0.0000 6.906E-04 0.0046 Pu-241 4.051E-09 0.0000 1.442E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.574E-07 0.0000 0.000E+00 0.0000 1.822E-09 0.0000 Pu-242 6.905E-07 0.0000 5.349E-04 0.0035 7.260E-19 0.0000 0.000E+00 0.0000 5.505E-03 0.0363 0.000E+00 0.0000 6.734E-04 0.0044 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 2.008E-17 0.0000 2.694E-19 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.166E-13 0.0000 0.000E+00 0.0000 4.844E-18 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 3.183E-03 0.0210 1.471E-03 0.0097 6.164E-12 0.0000 0.000E+00 0.0000 1.439E-01 0.9504 0.000E+00 0.0000 1.861E-03 0.0123

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 43 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.

Ag-110m 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Am-241 0.000E+00 0.0000 9.037E-04 0.0060 0.000E+00 0.0000 0.000E+00 0.0000 4.846E-05 0.0003 0.000E+00 0.0000 9.570E-04 0.0063 C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ce-144 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cm-242 0.000E+00 0.0000 5.413E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 4.492E-09 0.0000 0.000E+00 0.0000 2.249E-08 0.0000 Cm-243 0.000E+00 0.0000 5.823E-08 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 3.030E-09 0.0000 0.000E+00 0.0000 8.187E-06 0.0001 Co-57 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-58 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Co-60 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-134 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Cs-137 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.507E-11 0.0000 Eu-154 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Fe-55 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 H-3 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 I-129 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Mn-54 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Nb-94 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Ni-59 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.075E-04 0.0007 Ni-63 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 2.173E-07 0.0000 Np-237 0.000E+00 0.0000 1.627E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 5.576E-06 0.0000 0.000E+00 0.0000 1.367E-01 0.9029 Pu-238 0.000E+00 0.0000 1.069E-06 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.864E-07 0.0000 0.000E+00 0.0000 4.422E-06 0.0000 Pu-239 0.000E+00 0.0000 5.381E-09 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 8.962E-09 0.0000 0.000E+00 0.0000 6.881E-03 0.0454 Pu-241 0.000E+00 0.0000 3.810E-05 0.0003 0.000E+00 0.0000 0.000E+00 0.0000 2.023E-06 0.0000 0.000E+00 0.0000 4.029E-05 0.0003 Pu-242 0.000E+00 0.0000 4.276E-11 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.456E-10 0.0000 0.000E+00 0.0000 6.714E-03 0.0443 Ru-106 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-124 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sb-125 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sn-113 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Sr-90 0.000E+00 0.0000 4.444E-14 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 9.445E-13 0.0000 0.000E+00 0.0000 1.106E-12 0.0000 Tc-99 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zn-65 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Zr-95 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 9.445E-04 0.0062 0.000E+00 0.0000 0.000E+00 0.0000 5.697E-05 0.0004 0.000E+00 0.0000 1.515E-01 1.0000

  • Sum of all water independent and dependent pathways.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 44 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m+D Ag-110m+D 1.000E+00 5.459E-02 3.168E-02 6.390E-03 1.738E-07 2.721E-23 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 4.918E-03 4.868E-03 4.770E-03 4.442E-03 3.623E-03 6.872E-02 1.253E-01 9.494E-04 Am-241 Np-237+D 1.000E+00 3.331E-08 1.177E-07 2.872E-07 8.520E-07 2.246E-06 5.337E-06 8.168E-06 7.601E-06 Am-241 U-233 1.000E+00 1.173E-15 6.213E-15 2.596E-14 1.914E-13 1.381E-12 1.164E-11 1.207E-10 1.099E-09 Am-241 Th-229+D 1.000E+00 1.745E-19 2.017E-18 2.090E-17 5.146E-16 1.157E-14 3.246E-13 4.736E-12 3.760E-11 Am-241 DSR(j) 4.918E-03 4.868E-03 4.770E-03 4.443E-03 3.625E-03 6.872E-02 1.253E-01 9.570E-04 C-14 C-14 1.000E+00 4.032E-01 6.047E-01 6.226E-01 8.177E-09 4.204E-45 0.000E+00 0.000E+00 0.000E+00 Ce-144+D Ce-144+D 1.000E+00 1.225E-03 5.028E-04 8.467E-05 1.660E-07 3.045E-15 2.546E-42 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 3.172E-12 6.698E-13 2.986E-14 5.586E-19 1.732E-32 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 8.584E-14 1.813E-14 8.080E-16 1.511E-20 4.686E-34 0.000E+00 0.000E+00 0.000E+00 Cm-242 Pu-238 1.840E-09 3.065E-14 5.743E-14 6.351E-14 6.037E-14 5.146E-14 2.942E-14 5.955E-15 2.223E-17 Cm-242 DSR(j) 1.165E-13 7.555E-14 6.432E-14 6.037E-14 5.146E-14 2.942E-14 5.955E-15 2.223E-17 Cm-242 Cm-242 1.000E+00 4.665E-05 9.851E-06 4.391E-07 8.215E-12 2.547E-25 0.000E+00 0.000E+00 0.000E+00 Cm-242 Pu-238 1.000E+00 1.666E-05 3.121E-05 3.452E-05 3.281E-05 2.797E-05 1.599E-05 3.237E-06 1.208E-08 Cm-242 U-234 1.000E+00 4.920E-12 2.804E-11 9.002E-11 3.041E-10 8.265E-10 1.869E-09 2.857E-09 4.580E-09 Cm-242 Th-230 1.000E+00 1.307E-17 1.352E-16 9.353E-16 9.797E-15 8.175E-14 7.042E-13 3.276E-12 6.984E-12 Cm-242 Ra-226+D 1.000E+00 7.203E-20 2.268E-18 4.474E-17 1.680E-15 4.384E-14 1.293E-12 1.847E-11 1.448E-10 Cm-242 Pb-210+D 1.000E+00 8.065E-22 4.091E-20 1.335E-18 1.178E-16 7.496E-15 5.145E-13 1.240E-11 2.580E-10 Cm-242 Po-210 1.000E+00 1.902E-22 1.472E-20 7.617E-19 1.049E-16 8.027E-15 5.910E-13 4.077E-11 5.424E-09 Cm-242 DSR(j) 6.331E-05 4.106E-05 3.495E-05 3.281E-05 2.797E-05 1.599E-05 3.240E-06 2.249E-08 Cm-243 Cm-243 2.400E-03 1.236E-05 1.207E-05 1.149E-05 9.683E-06 5.938E-06 1.073E-06 8.073E-09 2.985E-16 Cm-243 Am-243+D 2.400E-03 1.071E-09 3.203E-09 7.265E-09 1.947E-08 4.099E-08 3.513E-07 1.666E-06 6.119E-08 Cm-243 Pu-239 2.400E-03 7.756E-15 5.585E-14 2.937E-13 2.456E-12 1.681E-11 9.458E-11 2.267E-10 3.009E-10 Cm-243 U-235+D 2.400E-03 1.610E-24 2.473E-23 2.883E-22 7.249E-21 1.491E-19 3.061E-18 3.187E-17 2.792E-16 Cm-243 Pa-231 2.400E-03 1.311E-27 5.276E-26 1.502E-24 1.202E-22 7.492E-21 6.588E-19 2.206E-17 8.962E-16 Cm-243 Ac-227+D 2.400E-03 3.328E-30 1.387E-28 4.227E-27 4.142E-25 3.764E-23 7.482E-20 5.276E-18 4.649E-16 Cm-243 DSR(j) 1.237E-05 1.207E-05 1.150E-05 9.702E-06 5.979E-06 1.424E-06 1.674E-06 6.149E-08 Cm-243 Cm-243 9.976E-01 5.139E-03 5.015E-03 4.776E-03 4.025E-03 2.468E-03 4.459E-04 3.356E-06 1.241E-13 Cm-243 Pu-239 9.976E-01 1.034E-07 3.190E-07 7.369E-07 2.048E-06 4.758E-06 8.234E-06 8.805E-06 8.126E-06 Cm-243 U-235+D 9.976E-01 2.892E-17 2.062E-16 1.084E-15 9.157E-15 6.495E-14 4.130E-13 1.317E-12 3.201E-12 Cm-243 Pa-231 9.976E-01 3.202E-20 5.982E-19 7.673E-18 2.047E-16 4.396E-15 9.838E-14 1.053E-12 1.175E-11 Cm-243 Ac-227+D 9.976E-01 8.183E-23 1.594E-21 2.220E-20 7.516E-19 2.444E-17 1.031E-15 1.321E-13 5.328E-12 Cm-243 DSR(j) 5.140E-03 5.016E-03 4.777E-03 4.027E-03 2.473E-03 4.541E-04 1.216E-05 8.126E-06 Co-57 Co-57 1.000E+00 4.737E-03 1.860E-03 2.868E-04 4.130E-07 3.141E-15 1.205E-43 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 1.274E-02 3.566E-04 2.793E-07 3.756E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 45 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Co-60 Co-60 1.000E+00 1.801E-01 1.579E-01 1.214E-01 4.828E-02 3.468E-03 3.444E-07 1.258E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 2.346E-01 1.676E-01 8.558E-02 8.135E-03 9.777E-06 5.886E-16 0.000E+00 0.000E+00 Cs-137+D Cs-137+D 1.000E+00 1.694E-01 1.655E-01 1.580E-01 1.344E-01 8.459E-02 1.674E-02 1.635E-04 1.507E-11 Eu-154 Eu-154 1.000E+00 4.210E-02 3.890E-02 3.322E-02 1.911E-02 3.938E-03 1.564E-05 2.160E-12 2.113E-36 Fe-55 Fe-55 1.000E+00 1.918E-04 1.483E-04 8.874E-05 1.469E-05 8.625E-08 1.337E-15 6.493E-38 0.000E+00 H-3 H-3 1.000E+00 1.812E-03 6.368E-04 3.512E-04 1.861E-07 4.564E-22 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 1.161E-01 2.192E+00 6.089E+00 2.979E+00 4.897E-05 8.815E-22 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 2.053E-02 9.122E-03 1.801E-03 6.167E-06 5.568E-13 1.231E-37 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 4.218E-02 5.078E-02 6.223E-02 1.691E-03 1.668E-10 5.021E-35 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.290E-04 1.290E-04 1.290E-04 1.288E-04 1.283E-04 1.267E-04 1.222E-04 1.075E-04 Ni-63 Ni-63 1.000E+00 3.533E-04 3.507E-04 3.455E-04 3.281E-04 2.830E-04 1.687E-04 3.844E-05 2.173E-07 Np-237+D Np-237+D 1.000E+00 2.683E-01 2.681E-01 2.678E-01 2.665E-01 2.629E-01 2.508E-01 2.192E-01 1.367E-01 Np-237+D U-233 1.000E+00 9.840E-09 2.083E-08 4.107E-08 1.106E-07 2.984E-07 8.429E-07 2.218E-06 8.954E-06 Np-237+D Th-229+D 1.000E+00 1.918E-12 1.086E-11 5.353E-11 4.604E-10 3.742E-09 3.678E-08 2.531E-07 1.294E-06 Np-237+D DSR(j) 2.683E-01 2.681E-01 2.678E-01 2.665E-01 2.629E-01 2.508E-01 2.192E-01 1.367E-01 Pu-238 Pu-238 1.840E-09 1.281E-11 1.270E-11 1.250E-11 1.182E-11 1.008E-11 5.762E-12 1.166E-12 4.353E-15 Pu-238 Pu-238 1.000E+00 6.960E-03 6.905E-03 6.795E-03 6.426E-03 5.477E-03 3.132E-03 6.339E-04 2.366E-06 Pu-238 U-234 1.000E+00 2.932E-09 9.287E-09 2.188E-08 6.372E-08 1.657E-07 3.692E-07 5.632E-07 9.031E-07 Pu-238 Th-230 1.000E+00 8.586E-15 5.305E-14 2.597E-13 2.172E-12 1.675E-11 1.401E-10 6.465E-10 1.375E-09 Pu-238 Ra-226+D 1.000E+00 6.144E-17 1.119E-15 1.439E-14 3.947E-13 9.171E-12 2.589E-10 3.653E-09 2.854E-08 Pu-238 Pb-210+D 1.000E+00 7.673E-19 2.193E-17 4.628E-16 2.887E-14 1.593E-12 1.034E-10 2.455E-09 5.093E-08 Pu-238 Po-210 1.000E+00 1.943E-19 8.514E-18 2.786E-16 2.605E-14 1.709E-12 1.188E-10 8.124E-09 1.072E-06 Pu-238 DSR(j) 6.960E-03 6.905E-03 6.795E-03 6.426E-03 5.477E-03 3.132E-03 6.345E-04 4.422E-06 Pu-239 Pu-239 1.000E+00 7.724E-03 7.723E-03 7.721E-03 7.715E-03 7.697E-03 7.635E-03 7.461E-03 6.881E-03 Pu-239 U-235+D 1.000E+00 3.091E-12 9.436E-12 2.209E-11 6.567E-11 1.844E-10 5.386E-10 1.257E-09 2.816E-09 Pu-239 Pa-231 1.000E+00 4.969E-15 4.165E-14 2.370E-13 2.172E-12 1.771E-11 1.644E-10 1.160E-09 1.091E-08 Pu-239 Ac-227+D 1.000E+00 1.278E-17 1.133E-16 7.166E-16 8.737E-15 1.112E-13 2.105E-12 1.786E-10 5.062E-09 Pu-239 DSR(j) 7.724E-03 7.723E-03 7.721E-03 7.715E-03 7.697E-03 7.635E-03 7.461E-03 6.881E-03

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 46 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Pu-241 Pu-241 1.000E+00 1.457E-04 1.388E-04 1.260E-04 8.993E-05 3.428E-05 1.172E-06 7.596E-11 1.663E-25 Pu-241 Am-241 1.000E+00 4.126E-06 1.163E-05 2.530E-05 6.183E-05 1.049E-04 1.496E-03 4.141E-03 4.003E-05 Pu-241 Np-237+D 1.000E+00 1.513E-11 1.320E-10 7.439E-10 6.143E-09 3.701E-08 1.514E-07 2.669E-07 2.510E-07 Pu-241 U-233 1.000E+00 4.956E-19 5.846E-18 5.175E-17 1.001E-15 1.686E-14 2.660E-13 3.428E-12 3.441E-11 Pu-241 Th-229+D 1.000E+00 6.165E-23 1.411E-21 2.983E-20 1.996E-18 1.104E-16 6.555E-15 1.355E-13 1.217E-12 Pu-241 DSR(j) 1.498E-04 1.504E-04 1.513E-04 1.518E-04 1.392E-04 1.497E-03 4.142E-03 4.029E-05 Pu-241+D Pu-241+D 2.450E-05 7.635E-08 7.275E-08 6.606E-08 4.714E-08 1.797E-08 6.145E-10 3.981E-14 8.714E-29 Pu-241+D Np-237+D 2.450E-05 8.088E-13 2.809E-12 6.605E-12 1.731E-11 3.353E-11 4.151E-11 3.658E-11 2.282E-11 Pu-241+D U-233 2.450E-05 2.847E-20 1.488E-19 6.061E-19 4.107E-18 2.403E-17 1.140E-16 3.357E-16 1.424E-15 Pu-241+D Th-229+D 2.450E-05 4.241E-24 4.860E-23 4.947E-22 1.145E-20 2.192E-19 4.141E-18 3.713E-17 2.083E-16 Pu-241+D DSR(j) 7.635E-08 7.275E-08 6.607E-08 4.715E-08 1.800E-08 6.560E-10 3.662E-11 2.282E-11 Pu-242 Pu-242 5.500E-06 4.035E-08 4.034E-08 4.034E-08 4.031E-08 4.024E-08 3.999E-08 3.929E-08 3.693E-08 Pu-242 Pu-242 5.400E-05 3.961E-07 3.961E-07 3.960E-07 3.958E-07 3.951E-07 3.926E-07 3.857E-07 3.625E-07 Pu-242 U-238 5.400E-05 7.815E-18 2.484E-17 5.898E-17 1.766E-16 4.969E-16 1.454E-15 3.882E-15 1.412E-14 Pu-242 DSR(j) 3.961E-07 3.961E-07 3.960E-07 3.958E-07 3.951E-07 3.926E-07 3.857E-07 3.625E-07 Pu-242 Pu-242 9.999E-01 7.336E-03 7.335E-03 7.334E-03 7.329E-03 7.316E-03 7.271E-03 7.143E-03 6.713E-03 Pu-242 U-238+D 9.999E-01 2.183E-13 6.817E-13 1.609E-12 4.803E-12 1.350E-11 3.950E-11 9.999E-11 3.100E-10 Pu-242 U-234 9.999E-01 1.646E-19 1.165E-18 6.141E-18 5.408E-17 4.353E-16 4.025E-15 3.360E-14 4.660E-13 Pu-242 Th-230 9.999E-01 3.651E-25 4.680E-24 4.943E-23 1.220E-21 2.822E-20 8.880E-19 1.732E-17 2.423E-16 Pu-242 Ra-226+D 9.999E-01 1.770E-27 6.837E-26 1.949E-24 1.622E-22 1.135E-20 1.177E-18 7.427E-16 6.460E-15 Pu-242 Pb-210+D 9.999E-01 1.932E-29 1.189E-27 5.418E-26 9.904E-24 1.632E-21 3.998E-19 3.045E-15 1.970E-14 Pu-242 Po-210 9.999E-01 4.496E-30 4.156E-28 2.936E-26 8.421E-24 1.707E-21 4.551E-19 8.876E-14 5.363E-13 Pu-242 DSR(j) 7.336E-03 7.335E-03 7.334E-03 7.329E-03 7.316E-03 7.271E-03 7.143E-03 6.713E-03 Ru-106+D Ru-106+D 1.000E+00 1.532E-02 6.208E-02 3.010E-02 8.081E-06 8.500E-19 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 1.327E-02 2.020E-04 6.398E-08 3.868E-22 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 7.407E-03 8.590E-03 7.384E-03 3.884E-05 2.571E-14 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 2.187E-03 2.537E-03 2.181E-03 1.147E-05 7.593E-15 0.000E+00 0.000E+00 0.000E+00 Sb-125 Te-125m 2.280E-01 3.160E-03 1.408E-02 1.511E-02 8.243E-05 5.456E-14 0.000E+00 0.000E+00 0.000E+00 Sb-125 DSR(j) 5.348E-03 1.661E-02 1.729E-02 9.390E-05 6.215E-14 0.000E+00 0.000E+00 0.000E+00 Sn-113+D Sn-113+D 1.000E+00 7.400E-03 9.405E-03 2.329E-04 1.652E-12 1.280E-38 0.000E+00 0.000E+00 0.000E+00 Sr-90+D Sr-90+D 1.000E+00 7.939E-01 7.709E-01 7.266E-01 5.909E-01 3.272E-01 4.189E-02 1.414E-04 1.106E-12 Tc-99 Tc-99 1.000E+00 1.310E-03 1.454E-03 1.740E-03 4.981E-05 4.916E-12 1.483E-36 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 8.180E-01 1.038E+00 2.374E-01 5.584E-06 5.311E-22 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 47 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)

(i) (j) Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95+D Zr-95+D 1.000E+00 6.297E-03 1.204E-04 4.400E-08 4.108E-20 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Zr-95+D Nb-95 1.000E+00 5.765E-03 2.255E-04 8.412E-08 7.851E-20 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Zr-95+D DSR(j) 1.206E-02 3.459E-04 1.281E-07 1.196E-19 0.000E+00 0.000E+00 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life ó 30 days) daughters.

Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m 4.579E+02 7.891E+02 3.912E+03 1.439E+08 *4.754E+15 *4.754E+15 *4.754E+15 *4.754E+15 Am-241 5.083E+03 5.135E+03 5.241E+03 5.627E+03 6.897E+03 3.638E+02 1.995E+02 2.612E+04 C-14 6.200E+01 4.134E+01 4.015E+01 3.058E+09 *4.455E+12 *4.455E+12 *4.455E+12 *4.455E+12 Ce-144 2.041E+04 4.972E+04 2.953E+05 1.506E+08 *3.191E+15 *3.191E+15 *3.191E+15 *3.191E+15 Cm-242 3.949E+05 6.088E+05 7.152E+05 7.620E+05 8.939E+05 1.563E+06 7.717E+06 1.111E+09 Cm-243 4.853E+03 4.972E+03 5.221E+03 6.193E+03 1.008E+04 5.488E+04 1.807E+06 3.053E+06 Co-57 5.278E+03 1.344E+04 8.716E+04 6.053E+07 7.960E+15 *8.465E+15 *8.465E+15 *8.465E+15 Co-58 1.962E+03 7.010E+04 8.951E+07 *3.183E+16 *3.183E+16 *3.183E+16 *3.183E+16 *3.183E+16 Co-60 1.388E+02 1.583E+02 2.060E+02 5.178E+02 7.210E+03 7.260E+07 *1.132E+15 *1.132E+15 Cs-134 1.065E+02 1.491E+02 2.921E+02 3.073E+03 2.557E+06 *1.295E+15 *1.295E+15 *1.295E+15 Cs-137 1.476E+02 1.511E+02 1.582E+02 1.860E+02 2.956E+02 1.493E+03 1.529E+05 1.659E+12 Eu-154 5.938E+02 6.426E+02 7.526E+02 1.308E+03 6.348E+03 1.598E+06 1.157E+13 *2.639E+14 Fe-55 1.304E+05 1.685E+05 2.817E+05 1.701E+06 2.898E+08 *2.410E+15 *2.410E+15 *2.410E+15 H-3 1.379E+04 3.926E+04 7.118E+04 1.344E+08 *9.597E+15 *9.597E+15 *9.597E+15 *9.597E+15 I-129 2.153E+02 1.140E+01 4.105E+00 8.392E+00 5.105E+05 *1.766E+08 *1.766E+08 *1.766E+08 Mn-54 1.218E+03 2.741E+03 1.388E+04 4.054E+06 4.490E+13 *7.746E+15 *7.746E+15 *7.746E+15 Nb-94 5.927E+02 4.923E+02 4.017E+02 1.478E+04 1.499E+11 *1.875E+11 *1.875E+11 *1.875E+11 Ni-59 1.937E+05 1.938E+05 1.938E+05 1.941E+05 1.948E+05 1.973E+05 2.047E+05 2.326E+05 Ni-63 7.076E+04 7.129E+04 7.235E+04 7.619E+04 8.834E+04 1.482E+05 6.503E+05 1.151E+08 Np-237 9.317E+01 9.324E+01 9.336E+01 9.380E+01 9.508E+01 9.967E+01 1.141E+02 1.828E+02 Pu-238 3.592E+03 3.621E+03 3.679E+03 3.890E+03 4.564E+03 7.982E+03 3.940E+04 5.654E+06 Pu-239 3.237E+03 3.237E+03 3.238E+03 3.240E+03 3.248E+03 3.274E+03 3.351E+03 3.633E+03 Pu-241 1.668E+05 1.661E+05 1.651E+05 1.647E+05 1.795E+05 1.670E+04 6.036E+03 6.206E+05 Pu-242 3.408E+03 3.408E+03 3.409E+03 3.411E+03 3.417E+03 3.438E+03 3.500E+03 3.724E+03 Ru-106 1.631E+03 4.027E+02 8.306E+02 3.094E+06 *3.348E+15 *3.348E+15 *3.348E+15 *3.348E+15 Sb-124 1.885E+03 1.238E+05 3.908E+08 *1.750E+16 *1.750E+16 *1.750E+16 *1.750E+16 *1.750E+16 Sb-125 1.960E+03 9.919E+02 1.013E+03 1.883E+05 2.845E+14 *1.033E+15 *1.033E+15 *1.033E+15 Sn-113 3.379E+03 2.658E+03 1.074E+05 1.513E+13 *1.005E+16 *1.005E+16 *1.005E+16 *1.005E+16 Sr-90 3.149E+01 3.243E+01 3.441E+01 4.231E+01 7.640E+01 5.968E+02 1.768E+05 2.261E+13 Tc-99 1.908E+04 1.720E+04 1.437E+04 5.019E+05 *1.697E+10 *1.697E+10 *1.697E+10 *1.697E+10 Zn-65 3.056E+01 2.410E+01 1.053E+02 4.477E+06 *8.245E+15 *8.245E+15 *8.245E+15 *8.245E+15 Zr-95 2.073E+03 7.227E+04 1.951E+08 *2.150E+16 *2.150E+16 *2.150E+16 *2.150E+16 *2.150E+16

  • At specific activity limit

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 48 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 5.05 n 0.01 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)

(i) (pCi/g) (years) (pCi/g) (pCi/g)

Ag-110m 1.000E+00 0.000E+00 5.459E-02 4.579E+02 8.556E-04 2.922E+04 Am-241 1.000E+00 263.9 n 0.5 1.265E-01 1.976E+02 4.672E-03 5.351E+03 C-14 1.000E+00 4.929 n 0.010 6.242E-01 4.005E+01 6.133E-01 4.076E+01 Ce-144 1.000E+00 0.000E+00 1.225E-03 2.041E+04 1.363E-05 1.834E+06 Cm-242 1.000E+00 0.000E+00 6.331E-05 3.949E+05 3.414E-05 7.322E+05 Cm-243 1.000E+00 0.000E+00 5.152E-03 4.853E+03 4.555E-03 5.489E+03 Co-57 1.000E+00 0.000E+00 4.737E-03 5.278E+03 4.219E-05 5.925E+05 Co-58 1.000E+00 0.000E+00 1.274E-02 1.962E+03 1.826E-10 1.369E+11 Co-60 1.000E+00 0.000E+00 1.801E-01 1.388E+02 9.264E-02 2.699E+02 Cs-134 1.000E+00 0.000E+00 2.346E-01 1.065E+02 4.295E-02 5.820E+02 Cs-137 1.000E+00 0.000E+00 1.694E-01 1.476E+02 1.507E-01 1.659E+02 Eu-154 1.000E+00 0.000E+00 4.210E-02 5.938E+02 2.825E-02 8.849E+02 Fe-55 1.000E+00 0.000E+00 1.918E-04 1.304E+05 5.240E-05 4.771E+05 H-3 1.000E+00 0.000E+00 1.812E-03 1.379E+04 3.049E-04 8.200E+04 I-129 1.000E+00 7.61 n 0.02 7.876E+00 3.174E+00 7.402E+00 3.377E+00 Mn-54 1.000E+00 0.000E+00 2.053E-02 1.218E+03 3.415E-04 7.321E+04 Nb-94 1.000E+00 4.929 n 0.010 6.448E-02 3.877E+02 6.427E-02 3.890E+02 Ni-59 1.000E+00 0.000E+00 1.290E-04 1.937E+05 1.289E-04 1.939E+05 Ni-63 1.000E+00 0.000E+00 3.533E-04 7.076E+04 3.403E-04 7.346E+04 Np-237 1.000E+00 0.000E+00 2.683E-01 9.317E+01 2.674E-01 9.349E+01 Pu-238 1.000E+00 0.000E+00 6.960E-03 3.592E+03 6.685E-03 3.740E+03 Pu-239 1.000E+00 0.000E+00 7.724E-03 3.237E+03 7.720E-03 3.239E+03 Pu-241 1.000E+00 288.3 n 0.6 4.146E-03 6.030E+03 1.519E-04 1.646E+05 Pu-242 1.000E+00 0.000E+00 7.336E-03 3.408E+03 7.333E-03 3.409E+03 Ru-106 1.000E+00 1.185 n 0.002 6.335E-02 3.946E+02 8.052E-03 3.105E+03 Sb-124 1.000E+00 0.000E+00 1.327E-02 1.885E+03 1.219E-11 2.050E+12 Sb-125 1.000E+00 1.748 n 0.003 2.818E-02 8.870E+02 1.588E-02 1.575E+03 Sn-113 1.000E+00 0.660 n 0.001 1.197E-02 2.088E+03 2.818E-06 8.872E+06 Sr-90 1.000E+00 0.000E+00 7.939E-01 3.149E+01 6.839E-01 3.655E+01 Tc-99 1.000E+00 4.929 n 0.010 1.796E-03 1.392E+04 1.794E-03 1.394E+04 Zn-65 1.000E+00 0.872 n 0.002 1.052E+00 2.376E+01 3.081E-02 8.114E+02 Zr-95 1.000E+00 0.000E+00 1.206E-02 2.073E+03 3.834E-11 6.520E+11

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 49 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m Ag-110m 1.000E+00 5.459E-02 3.168E-02 6.390E-03 1.738E-07 2.721E-23 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 4.918E-03 4.868E-03 4.770E-03 4.442E-03 3.623E-03 6.872E-02 1.253E-01 9.494E-04 Am-241 Pu-241 1.000E+00 4.126E-06 1.163E-05 2.530E-05 6.183E-05 1.049E-04 1.496E-03 4.141E-03 4.003E-05 Am-241 DOSE(j) 4.922E-03 4.880E-03 4.795E-03 4.503E-03 3.728E-03 7.022E-02 1.295E-01 9.894E-04 Np-237 Am-241 1.000E+00 3.331E-08 1.177E-07 2.872E-07 8.520E-07 2.246E-06 5.337E-06 8.168E-06 7.601E-06 Np-237 Np-237 1.000E+00 2.683E-01 2.681E-01 2.678E-01 2.665E-01 2.629E-01 2.508E-01 2.192E-01 1.367E-01 Np-237 Pu-241 1.000E+00 1.513E-11 1.320E-10 7.439E-10 6.143E-09 3.701E-08 1.514E-07 2.669E-07 2.510E-07 Np-237 Pu-241 2.450E-05 8.088E-13 2.809E-12 6.605E-12 1.731E-11 3.353E-11 4.151E-11 3.658E-11 2.282E-11 Np-237 DOSE(j) 2.683E-01 2.681E-01 2.678E-01 2.665E-01 2.629E-01 2.508E-01 2.192E-01 1.367E-01 U-233 Am-241 1.000E+00 1.173E-15 6.213E-15 2.596E-14 1.914E-13 1.381E-12 1.164E-11 1.207E-10 1.099E-09 U-233 Np-237 1.000E+00 9.840E-09 2.083E-08 4.107E-08 1.106E-07 2.984E-07 8.429E-07 2.218E-06 8.954E-06 U-233 Pu-241 1.000E+00 4.956E-19 5.846E-18 5.175E-17 1.001E-15 1.686E-14 2.660E-13 3.428E-12 3.441E-11 U-233 Pu-241 2.450E-05 2.847E-20 1.488E-19 6.061E-19 4.107E-18 2.403E-17 1.140E-16 3.357E-16 1.424E-15 U-233 DOSE(j) 9.840E-09 2.083E-08 4.107E-08 1.106E-07 2.984E-07 8.429E-07 2.218E-06 8.955E-06 Th-229 Am-241 1.000E+00 1.745E-19 2.017E-18 2.090E-17 5.146E-16 1.157E-14 3.246E-13 4.736E-12 3.760E-11 Th-229 Np-237 1.000E+00 1.918E-12 1.086E-11 5.353E-11 4.604E-10 3.742E-09 3.678E-08 2.531E-07 1.294E-06 Th-229 Pu-241 1.000E+00 6.165E-23 1.411E-21 2.983E-20 1.996E-18 1.104E-16 6.555E-15 1.355E-13 1.217E-12 Th-229 Pu-241 2.450E-05 4.241E-24 4.860E-23 4.947E-22 1.145E-20 2.192E-19 4.141E-18 3.713E-17 2.083E-16 Th-229 DOSE(j) 1.918E-12 1.086E-11 5.353E-11 4.604E-10 3.742E-09 3.678E-08 2.531E-07 1.294E-06 C-14 C-14 1.000E+00 4.032E-01 6.047E-01 6.226E-01 8.177E-09 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Ce-144 Ce-144 1.000E+00 1.225E-03 5.028E-04 8.467E-05 1.660E-07 3.045E-15 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 3.172E-12 6.698E-13 2.986E-14 5.586E-19 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 8.584E-14 1.813E-14 8.080E-16 1.511E-20 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Cm-242 DOSE(j) 3.258E-12 6.880E-13 3.067E-14 5.737E-19 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.840E-09 3.065E-14 5.743E-14 6.351E-14 6.037E-14 5.146E-14 2.942E-14 5.955E-15 2.223E-17 Pu-238 Pu-238 1.840E-09 1.281E-11 1.270E-11 1.250E-11 1.182E-11 1.008E-11 5.762E-12 1.166E-12 4.353E-15 Pu-238 DOSE(j) 1.284E-11 1.276E-11 1.257E-11 1.188E-11 1.013E-11 5.791E-12 1.172E-12 4.375E-15 Cm-242 Cm-242 1.000E+00 4.665E-05 9.851E-06 4.391E-07 8.215E-12 2.547E-25 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.000E+00 1.666E-05 3.121E-05 3.452E-05 3.281E-05 2.797E-05 1.599E-05 3.237E-06 1.208E-08 U-234 Cm-242 1.000E+00 4.920E-12 2.804E-11 9.002E-11 3.041E-10 8.265E-10 1.869E-09 2.857E-09 4.580E-09 U-234 Pu-238 1.000E+00 2.932E-09 9.287E-09 2.188E-08 6.372E-08 1.657E-07 3.692E-07 5.632E-07 9.031E-07 U-234 Pu-242 9.999E-01 1.646E-19 1.165E-18 6.141E-18 5.408E-17 4.353E-16 4.025E-15 3.360E-14 4.660E-13 U-234 DOSE(j) 2.937E-09 9.315E-09 2.197E-08 6.402E-08 1.666E-07 3.710E-07 5.660E-07 9.076E-07 Th-230 Cm-242 1.000E+00 1.307E-17 1.352E-16 9.353E-16 9.797E-15 8.175E-14 7.042E-13 3.276E-12 6.984E-12 Th-230 Pu-238 1.000E+00 8.586E-15 5.305E-14 2.597E-13 2.172E-12 1.675E-11 1.401E-10 6.465E-10 1.375E-09 Th-230 Pu-242 9.999E-01 3.651E-25 4.680E-24 4.943E-23 1.220E-21 2.822E-20 8.880E-19 1.732E-17 2.423E-16 Th-230 DOSE(j) 8.599E-15 5.318E-14 2.606E-13 2.182E-12 1.683E-11 1.408E-10 6.498E-10 1.382E-09

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 50 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ra-226 Cm-242 1.000E+00 7.203E-20 2.268E-18 4.474E-17 1.680E-15 4.384E-14 1.293E-12 1.847E-11 1.448E-10 Ra-226 Pu-238 1.000E+00 6.144E-17 1.119E-15 1.439E-14 3.947E-13 9.171E-12 2.589E-10 3.653E-09 2.854E-08 Ra-226 Pu-242 9.999E-01 1.770E-27 6.837E-26 1.949E-24 1.622E-22 1.135E-20 1.177E-18 7.427E-16 6.460E-15 Ra-226 DOSE(j) 6.151E-17 1.121E-15 1.444E-14 3.964E-13 9.215E-12 2.601E-10 3.672E-09 2.868E-08 Pb-210 Cm-242 1.000E+00 8.065E-22 4.091E-20 1.335E-18 1.178E-16 7.496E-15 5.145E-13 1.240E-11 2.580E-10 Pb-210 Pu-238 1.000E+00 7.673E-19 2.193E-17 4.628E-16 2.887E-14 1.593E-12 1.034E-10 2.455E-09 5.093E-08 Pb-210 Pu-242 9.999E-01 1.923E-29 1.189E-27 5.418E-26 9.904E-24 1.632E-21 3.998E-19 3.045E-15 1.970E-14 Pb-210 DOSE(j) 7.681E-19 2.197E-17 4.641E-16 2.899E-14 1.601E-12 1.039E-10 2.467E-09 5.119E-08 Po-210 Cm-242 1.000E+00 1.902E-22 1.472E-20 7.617E-19 1.049E-16 8.027E-15 5.910E-13 4.077E-11 5.424E-09 Po-210 Pu-238 1.000E+00 1.943E-19 8.514E-18 2.786E-16 2.605E-14 1.709E-12 1.188E-10 8.124E-09 1.072E-06 Po-210 Pu-242 9.999E-01 4.490E-30 4.149E-28 2.936E-26 8.421E-24 1.707E-21 4.551E-19 8.876E-14 5.363E-13 Po-210 DOSE(j) 1.945E-19 8.529E-18 2.793E-16 2.615E-14 1.717E-12 1.194E-10 8.164E-09 1.077E-06 Cm-243 Cm-243 2.400E-03 1.236E-05 1.207E-05 1.149E-05 9.683E-06 5.938E-06 1.073E-06 8.073E-09 2.985E-16 Cm-243 Cm-243 9.976E-01 5.139E-03 5.015E-03 4.776E-03 4.025E-03 2.468E-03 4.459E-04 3.356E-06 1.241E-13 Cm-243 DOSE(j) 5.152E-03 5.027E-03 4.788E-03 4.035E-03 2.474E-03 4.469E-04 3.364E-06 1.244E-13 Am-243 Cm-243 2.400E-03 1.071E-09 3.203E-09 7.265E-09 1.947E-08 4.099E-08 3.513E-07 1.666E-06 6.119E-08 Pu-239 Cm-243 2.400E-03 7.756E-15 5.585E-14 2.937E-13 2.456E-12 1.681E-11 9.458E-11 2.267E-10 3.009E-10 Pu-239 Cm-243 9.976E-01 1.034E-07 3.190E-07 7.369E-07 2.048E-06 4.758E-06 8.234E-06 8.805E-06 8.126E-06 Pu-239 Pu-239 1.000E+00 7.724E-03 7.723E-03 7.721E-03 7.715E-03 7.697E-03 7.635E-03 7.461E-03 6.881E-03 Pu-239 DOSE(j) 7.724E-03 7.724E-03 7.722E-03 7.717E-03 7.702E-03 7.644E-03 7.470E-03 6.889E-03 U-235 Cm-243 2.400E-03 1.610E-24 2.473E-23 2.883E-22 7.249E-21 1.491E-19 3.061E-18 3.187E-17 2.792E-16 U-235 Cm-243 9.976E-01 2.892E-17 2.062E-16 1.084E-15 9.157E-15 6.495E-14 4.130E-13 1.317E-12 3.201E-12 U-235 Pu-239 1.000E+00 3.091E-12 9.436E-12 2.209E-11 6.567E-11 1.844E-10 5.386E-10 1.257E-09 2.816E-09 U-235 DOSE(j) 3.092E-12 9.436E-12 2.209E-11 6.568E-11 1.844E-10 5.390E-10 1.258E-09 2.819E-09 Pa-231 Cm-243 2.400E-03 1.311E-27 5.276E-26 1.502E-24 1.202E-22 7.492E-21 6.588E-19 2.206E-17 8.962E-16 Pa-231 Cm-243 9.976E-01 3.202E-20 5.982E-19 7.673E-18 2.047E-16 4.396E-15 9.838E-14 1.053E-12 1.175E-11 Pa-231 Pu-239 1.000E+00 4.969E-15 4.165E-14 2.370E-13 2.172E-12 1.771E-11 1.644E-10 1.160E-09 1.091E-08 Pa-231 DOSE(j) 4.969E-15 4.165E-14 2.371E-13 2.173E-12 1.772E-11 1.645E-10 1.161E-09 1.092E-08 Ac-227 Cm-243 2.400E-03 3.185E-30 1.387E-28 4.227E-27 4.142E-25 3.764E-23 7.482E-20 5.276E-18 4.649E-16 Ac-227 Cm-243 9.976E-01 8.183E-23 1.594E-21 2.220E-20 7.516E-19 2.444E-17 1.031E-15 1.321E-13 5.328E-12 Ac-227 Pu-239 1.000E+00 1.278E-17 1.133E-16 7.166E-16 8.737E-15 1.112E-13 2.105E-12 1.786E-10 5.062E-09 Ac-227 DOSE(j) 1.278E-17 1.133E-16 7.166E-16 8.738E-15 1.113E-13 2.106E-12 1.787E-10 5.068E-09 Co-57 Co-57 1.000E+00 4.737E-03 1.860E-03 2.868E-04 4.130E-07 3.141E-15 0.000E+00 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 1.274E-02 3.566E-04 2.793E-07 3.756E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Co-60 Co-60 1.000E+00 1.801E-01 1.579E-01 1.214E-01 4.828E-02 3.468E-03 3.444E-07 1.258E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 2.346E-01 1.676E-01 8.558E-02 8.135E-03 9.777E-06 5.886E-16 0.000E+00 0.000E+00 Cs-137 Cs-137 1.000E+00 1.694E-01 1.655E-01 1.580E-01 1.344E-01 8.459E-02 1.674E-02 1.635E-04 1.507E-11

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 51 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Eu-154 Eu-154 1.000E+00 4.210E-02 3.890E-02 3.322E-02 1.911E-02 3.938E-03 1.564E-05 2.160E-12 0.000E+00 Fe-55 Fe-55 1.000E+00 1.918E-04 1.483E-04 8.874E-05 1.469E-05 8.625E-08 1.337E-15 0.000E+00 0.000E+00 H-3 H-3 1.000E+00 1.812E-03 6.368E-04 3.512E-04 1.861E-07 4.564E-22 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 1.161E-01 2.192E+00 6.089E+00 2.979E+00 4.897E-05 8.815E-22 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 2.053E-02 9.122E-03 1.801E-03 6.167E-06 5.568E-13 0.000E+00 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 4.218E-02 5.078E-02 6.223E-02 1.691E-03 1.668E-10 0.000E+00 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.290E-04 1.290E-04 1.290E-04 1.288E-04 1.283E-04 1.267E-04 1.222E-04 1.075E-04 Ni-63 Ni-63 1.000E+00 3.533E-04 3.507E-04 3.455E-04 3.281E-04 2.830E-04 1.687E-04 3.844E-05 2.173E-07 Pu-238 Pu-238 1.000E+00 6.960E-03 6.905E-03 6.795E-03 6.426E-03 5.477E-03 3.132E-03 6.339E-04 2.366E-06 Pu-241 Pu-241 1.000E+00 1.457E-04 1.388E-04 1.260E-04 8.993E-05 3.428E-05 1.172E-06 7.596E-11 1.663E-25 Pu-241 Pu-241 2.450E-05 7.635E-08 7.275E-08 6.606E-08 4.714E-08 1.797E-08 6.145E-10 3.981E-14 8.639E-29 Pu-241 DOSE(j) 1.457E-04 1.389E-04 1.261E-04 8.998E-05 3.430E-05 1.173E-06 7.600E-11 1.663E-25 Pu-242 Pu-242 5.500E-06 4.035E-08 4.034E-08 4.034E-08 4.031E-08 4.024E-08 3.999E-08 3.929E-08 3.693E-08 Pu-242 Pu-242 5.400E-05 3.961E-07 3.961E-07 3.960E-07 3.958E-07 3.951E-07 3.926E-07 3.857E-07 3.625E-07 Pu-242 DOSE(j) 4.365E-07 4.365E-07 4.364E-07 4.361E-07 4.353E-07 4.326E-07 4.250E-07 3.995E-07 U-238 Pu-242 5.400E-05 7.815E-18 2.484E-17 5.898E-17 1.766E-16 4.969E-16 1.454E-15 3.882E-15 1.412E-14 U-238 Pu-242 9.999E-01 2.183E-13 6.817E-13 1.609E-12 4.803E-12 1.350E-11 3.950E-11 9.999E-11 3.100E-10 U-238 DOSE(j) 2.183E-13 6.818E-13 1.609E-12 4.803E-12 1.350E-11 3.951E-11 1.000E-10 3.100E-10 Pu-242 Pu-242 9.999E-01 7.336E-03 7.335E-03 7.334E-03 7.329E-03 7.316E-03 7.271E-03 7.143E-03 6.713E-03 Ru-106 Ru-106 1.000E+00 1.532E-02 6.208E-02 3.010E-02 8.081E-06 8.500E-19 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 1.327E-02 2.020E-04 6.398E-08 3.868E-22 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 7.407E-03 8.590E-03 7.384E-03 3.884E-05 2.571E-14 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 2.187E-03 2.537E-03 2.181E-03 1.147E-05 7.593E-15 0.000E+00 0.000E+00 0.000E+00 Sb-125 DOSE(j) 9.594E-03 1.113E-02 9.565E-03 5.031E-05 3.330E-14 0.000E+00 0.000E+00 0.000E+00 Te-125m Sb-125 2.280E-01 3.160E-03 1.408E-02 1.511E-02 8.243E-05 5.456E-14 0.000E+00 0.000E+00 0.000E+00 Sn-113 Sn-113 1.000E+00 7.400E-03 9.405E-03 2.329E-04 1.652E-12 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sr-90 Sr-90 1.000E+00 7.939E-01 7.709E-01 7.266E-01 5.909E-01 3.272E-01 4.189E-02 1.414E-04 1.106E-12 Tc-99 Tc-99 1.000E+00 1.310E-03 1.454E-03 1.740E-03 4.981E-05 4.916E-12 0.000E+00 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 8.180E-01 1.038E+00 2.374E-01 5.584E-06 5.311E-22 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 52 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) DOSE(j,t), mrem/yr (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95 Zr-95 1.000E+00 6.297E-03 1.204E-04 4.400E-08 4.108E-20 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Nb-95 Zr-95 1.000E+00 5.765E-03 2.255E-04 8.412E-08 7.851E-20 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 53 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ag-110m Ag-110m 1.000E+00 1.000E+00 1.621E-01 4.261E-03 1.254E-08 1.973E-24 0.000E+00 0.000E+00 0.000E+00 Am-241 Am-241 1.000E+00 1.000E+00 9.899E-01 9.699E-01 9.031E-01 7.366E-01 3.609E-01 4.700E-02 3.747E-05 Am-241 Pu-241 1.000E+00 0.000E+00 1.558E-03 4.410E-03 1.205E-02 2.114E-02 1.488E-02 1.982E-03 1.580E-06 Am-241 S(j): 1.000E+00 9.914E-01 9.743E-01 9.152E-01 7.577E-01 3.758E-01 4.898E-02 3.905E-05 Np-237 Am-241 1.000E+00 0.000E+00 3.221E-07 9.560E-07 3.069E-06 8.284E-06 1.953E-05 2.620E-05 1.734E-05 Np-237 Np-237 1.000E+00 1.000E+00 9.993E-01 9.980E-01 9.933E-01 9.800E-01 9.348E-01 8.169E-01 5.096E-01 Np-237 Pu-241 1.000E+00 0.000E+00 2.547E-10 2.204E-09 2.144E-08 1.354E-07 5.574E-07 8.702E-07 5.849E-07 Np-237 Pu-241 2.450E-05 0.000E+00 7.745E-12 2.214E-11 6.273E-11 1.243E-10 1.547E-10 1.363E-10 8.505E-11 Np-237 S(j): 1.000E+00 9.993E-01 9.980E-01 9.933E-01 9.800E-01 9.348E-01 8.169E-01 5.096E-01 U-233 Am-241 1.000E+00 0.000E+00 7.049E-13 6.284E-12 6.753E-11 5.533E-10 4.479E-09 1.793E-08 2.484E-08 U-233 Np-237 1.000E+00 0.000E+00 4.364E-06 1.304E-05 4.284E-05 1.233E-04 3.568E-04 7.262E-04 7.502E-04 U-233 Pu-241 1.000E+00 0.000E+00 3.727E-16 9.757E-15 3.250E-13 6.594E-12 1.060E-10 5.573E-10 8.328E-10 U-233 Pu-241 2.450E-05 0.000E+00 1.705E-17 1.483E-16 1.466E-15 9.725E-15 4.814E-14 1.154E-13 1.247E-13 U-233 S(j): 0.000E+00 4.364E-06 1.304E-05 4.284E-05 1.233E-04 3.568E-04 7.262E-04 7.502E-04 Th-229 Am-241 1.000E+00 0.000E+00 2.221E-17 5.955E-16 2.151E-14 5.410E-13 1.579E-11 2.320E-10 1.807E-09 Th-229 Np-237 1.000E+00 0.000E+00 2.062E-10 1.851E-09 2.036E-08 1.782E-07 1.798E-06 1.246E-05 6.357E-05 Th-229 Pu-241 1.000E+00 0.000E+00 8.827E-21 6.975E-19 7.907E-17 5.088E-15 3.180E-13 6.638E-12 5.859E-11 Th-229 Pu-241 2.450E-05 0.000E+00 5.391E-22 1.418E-20 4.810E-19 1.030E-17 2.020E-16 1.828E-15 1.024E-14 Th-229 S(j): 0.000E+00 2.062E-10 1.851E-09 2.036E-08 1.782E-07 1.798E-06 1.246E-05 6.357E-05 C-14 C-14 1.000E+00 1.000E+00 1.615E-02 4.167E-06 1.036E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Ce-144 Ce-144 1.000E+00 1.000E+00 4.104E-01 6.911E-02 1.355E-04 2.486E-12 2.080E-39 0.000E+00 0.000E+00 Cm-242 Cm-242 6.800E-08 6.800E-08 1.436E-08 6.401E-10 1.197E-14 3.712E-28 0.000E+00 0.000E+00 0.000E+00 Cm-242 Cm-242 1.840E-09 1.840E-09 3.885E-10 1.732E-11 3.240E-16 1.004E-29 0.000E+00 0.000E+00 0.000E+00 Cm-242 S(j): 6.984E-08 1.475E-08 6.574E-10 1.230E-14 3.812E-28 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.840E-09 0.000E+00 7.336E-12 9.084E-12 8.674E-12 7.393E-12 4.227E-12 8.557E-13 3.193E-15 Pu-238 Pu-238 1.840E-09 1.840E-09 1.825E-09 1.796E-09 1.699E-09 1.448E-09 8.279E-10 1.676E-10 6.254E-13 Pu-238 S(j): 1.840E-09 1.833E-09 1.806E-09 1.707E-09 1.455E-09 8.321E-10 1.684E-10 6.286E-13 Cm-242 Cm-242 1.000E+00 1.000E+00 2.111E-01 9.413E-03 1.761E-07 5.459E-21 0.000E+00 0.000E+00 0.000E+00 Pu-238 Cm-242 1.000E+00 0.000E+00 3.987E-03 4.937E-03 4.714E-03 4.018E-03 2.297E-03 4.650E-04 1.736E-06 U-234 Cm-242 1.000E+00 0.000E+00 7.066E-09 3.354E-08 1.277E-07 3.576E-07 8.171E-07 8.379E-07 9.911E-08 U-234 Pu-238 1.000E+00 0.000E+00 2.819E-06 8.360E-06 2.677E-05 7.169E-05 1.613E-04 1.648E-04 1.947E-05 U-234 Pu-242 9.999E-01 0.000E+00 2.194E-16 1.965E-15 2.148E-14 1.846E-13 1.747E-12 1.012E-11 3.011E-11 U-234 S(j): 0.000E+00 2.826E-06 8.394E-06 2.690E-05 7.204E-05 1.621E-04 1.656E-04 1.957E-05 Th-230 Cm-242 1.000E+00 0.000E+00 2.367E-14 3.826E-13 5.500E-12 5.001E-11 4.435E-10 2.078E-09 4.398E-09 Th-230 Pu-238 1.000E+00 0.000E+00 1.271E-11 1.135E-10 1.228E-09 1.025E-08 8.825E-08 4.101E-07 8.659E-07 Th-230 Pu-242 9.999E-01 0.000E+00 6.587E-22 1.772E-20 6.483E-19 1.691E-17 5.552E-16 1.080E-14 1.509E-13 Th-230 S(j): 0.000E+00 1.274E-11 1.139E-10 1.234E-09 1.030E-08 8.869E-08 4.122E-07 8.703E-07

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 54 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Ra-226 Cm-242 1.000E+00 0.000E+00 2.738E-18 1.437E-16 7.512E-15 2.135E-13 6.477E-12 9.192E-11 5.240E-10 Ra-226 Pu-238 1.000E+00 0.000E+00 1.836E-15 4.922E-14 1.778E-12 4.470E-11 1.297E-09 1.818E-08 1.032E-07 Ra-226 Pu-242 9.999E-01 0.000E+00 7.132E-26 5.754E-24 7.006E-22 5.455E-20 5.872E-18 3.253E-16 1.221E-14 Ra-226 S(j): 0.000E+00 1.839E-15 4.936E-14 1.785E-12 4.492E-11 1.304E-09 1.827E-08 1.037E-07 Pb-210 Cm-242 1.000E+00 0.000E+00 1.770E-20 2.917E-18 5.235E-16 4.145E-14 3.072E-12 7.031E-11 4.847E-10 Pb-210 Pu-238 1.000E+00 0.000E+00 1.418E-17 1.128E-15 1.304E-13 8.829E-12 6.176E-10 1.391E-08 9.546E-08 Pb-210 Pu-242 9.999E-01 0.000E+00 4.411E-28 1.057E-25 4.141E-23 8.790E-21 2.364E-18 2.227E-16 1.073E-14 Pb-210 S(j): 0.000E+00 1.420E-17 1.130E-15 1.310E-13 8.870E-12 6.206E-10 1.398E-08 9.595E-08 Po-210 Cm-242 1.000E+00 0.000E+00 4.364E-21 1.515E-18 4.199E-16 3.838E-14 2.991E-12 6.936E-11 4.800E-10 Po-210 Pu-238 1.000E+00 0.000E+00 3.939E-18 6.196E-16 1.058E-13 8.185E-12 6.012E-10 1.372E-08 9.454E-08 Po-210 Pu-242 9.999E-01 0.000E+00 1.059E-28 5.252E-26 3.207E-23 8.003E-21 2.287E-18 2.192E-16 1.061E-14 Po-210 S(j): 0.000E+00 3.943E-18 6.212E-16 1.062E-13 8.223E-12 6.042E-10 1.379E-08 9.502E-08 Cm-243 Cm-243 2.400E-03 2.400E-03 2.342E-03 2.230E-03 1.879E-03 1.153E-03 2.082E-04 1.567E-06 5.795E-14 Cm-243 Cm-243 9.976E-01 9.976E-01 9.735E-01 9.271E-01 7.812E-01 4.791E-01 8.654E-02 6.513E-04 2.409E-11 Cm-243 S(j): 1.000E+00 9.758E-01 9.293E-01 7.831E-01 4.803E-01 8.675E-02 6.529E-04 2.415E-11 Am-243 Cm-243 2.400E-03 0.000E+00 2.217E-07 6.435E-07 1.912E-06 4.153E-06 4.761E-06 1.048E-06 2.425E-09 Pu-239 Cm-243 2.400E-03 0.000E+00 3.211E-12 2.826E-11 2.909E-10 2.119E-09 1.208E-08 2.654E-08 2.774E-08 Pu-239 Cm-243 9.976E-01 0.000E+00 2.838E-05 8.310E-05 2.548E-04 6.097E-04 1.065E-03 1.140E-03 1.052E-03 Pu-239 Pu-239 1.000E+00 1.000E+00 9.999E-01 9.997E-01 9.988E-01 9.965E-01 9.885E-01 9.659E-01 8.908E-01 Pu-239 S(j): 1.000E+00 9.999E-01 9.997E-01 9.991E-01 9.971E-01 9.896E-01 9.671E-01 8.919E-01 U-235 Cm-243 2.400E-03 0.000E+00 1.056E-21 2.800E-20 9.731E-19 2.202E-17 4.611E-16 3.352E-15 7.630E-15 U-235 Cm-243 9.976E-01 0.000E+00 1.402E-14 1.238E-13 1.291E-12 9.745E-12 6.332E-11 1.932E-10 2.973E-10 U-235 Pu-239 1.000E+00 0.000E+00 9.831E-10 2.939E-09 9.675E-09 2.802E-08 8.276E-08 1.802E-07 2.533E-07 U-235 S(j): 0.000E+00 9.831E-10 2.939E-09 9.676E-09 2.803E-08 8.282E-08 1.804E-07 2.536E-07 Pa-231 Cm-243 2.400E-03 0.000E+00 5.592E-27 4.458E-25 5.205E-23 3.608E-21 2.671E-19 6.288E-18 3.927E-17 Pa-231 Cm-243 9.976E-01 0.000E+00 9.901E-20 2.632E-18 9.232E-17 2.145E-15 4.933E-14 4.587E-13 1.619E-12 Pa-231 Pu-239 1.000E+00 0.000E+00 1.039E-14 9.311E-14 1.018E-12 8.741E-12 8.263E-11 4.770E-10 1.400E-09 Pa-231 S(j): 0.000E+00 1.039E-14 9.312E-14 1.018E-12 8.743E-12 8.268E-11 4.775E-10 1.402E-09 Ac-227 Cm-243 2.400E-03 0.000E+00 3.541E-29 8.378E-27 3.143E-24 5.905E-22 1.070E-19 4.074E-18 3.041E-17 Ac-227 Cm-243 9.976E-01 0.000E+00 7.829E-22 6.163E-20 6.892E-18 4.253E-16 2.261E-14 3.137E-13 1.261E-12 Ac-227 Pu-239 1.000E+00 0.000E+00 1.093E-16 2.882E-15 9.845E-14 2.140E-12 4.208E-11 3.338E-10 1.092E-09 Ac-227 S(j): 0.000E+00 1.093E-16 2.882E-15 9.846E-14 2.140E-12 4.211E-11 3.341E-10 1.094E-09 Co-57 Co-57 1.000E+00 1.000E+00 3.927E-01 6.056E-02 8.720E-05 6.630E-13 2.542E-41 0.000E+00 0.000E+00 Co-58 Co-58 1.000E+00 1.000E+00 2.799E-02 2.192E-05 2.947E-16 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Co-60 Co-60 1.000E+00 1.000E+00 8.766E-01 6.737E-01 2.680E-01 1.925E-02 1.912E-06 6.986E-18 0.000E+00 Cs-134 Cs-134 1.000E+00 1.000E+00 7.145E-01 3.647E-01 3.467E-02 4.167E-05 2.509E-15 1.541E-44 0.000E+00 Cs-137 Cs-137 1.000E+00 1.000E+00 9.771E-01 9.329E-01 7.934E-01 4.994E-01 9.884E-02 9.656E-04 8.898E-11

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 55 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Eu-154 Eu-154 1.000E+00 1.000E+00 9.241E-01 7.890E-01 4.539E-01 9.354E-02 3.716E-04 5.131E-11 5.020E-35 Fe-55 Fe-55 1.000E+00 1.000E+00 7.734E-01 4.627E-01 7.662E-02 4.497E-04 6.970E-12 3.385E-34 0.000E+00 H-3 H-3 1.000E+00 1.000E+00 1.881E-01 6.643E-03 5.357E-08 1.201E-22 0.000E+00 0.000E+00 0.000E+00 I-129 I-129 1.000E+00 1.000E+00 5.766E-01 1.917E-01 4.062E-03 6.703E-08 1.224E-24 0.000E+00 0.000E+00 Mn-54 Mn-54 1.000E+00 1.000E+00 4.444E-01 8.777E-02 3.005E-04 2.713E-11 5.997E-36 0.000E+00 0.000E+00 Nb-94 Nb-94 1.000E+00 1.000E+00 4.465E-01 8.900E-02 3.148E-04 3.119E-11 9.553E-36 0.000E+00 0.000E+00 Ni-59 Ni-59 1.000E+00 1.000E+00 9.998E-01 9.995E-01 9.982E-01 9.945E-01 9.819E-01 9.466E-01 8.329E-01 Ni-63 Ni-63 1.000E+00 1.000E+00 9.926E-01 9.781E-01 9.287E-01 8.011E-01 4.774E-01 1.088E-01 6.150E-04 Pu-238 Pu-238 1.000E+00 1.000E+00 9.920E-01 9.763E-01 9.232E-01 7.869E-01 4.499E-01 9.108E-02 3.399E-04 Pu-241 Pu-241 1.000E+00 1.000E+00 9.529E-01 8.653E-01 6.174E-01 2.353E-01 8.049E-03 5.215E-07 1.141E-21 Pu-241 Pu-241 2.450E-05 2.450E-05 2.335E-05 2.120E-05 1.513E-05 5.766E-06 1.972E-07 1.278E-11 2.796E-26 Pu-241 S(j): 1.000E+00 9.529E-01 8.653E-01 6.174E-01 2.354E-01 8.049E-03 5.215E-07 1.141E-21 Pu-242 Pu-242 5.500E-06 5.500E-06 5.500E-06 5.499E-06 5.495E-06 5.485E-06 5.451E-06 5.356E-06 5.033E-06 Pu-242 Pu-242 5.400E-05 5.400E-05 5.399E-05 5.399E-05 5.395E-05 5.386E-05 5.352E-05 5.258E-05 4.942E-05 Pu-242 S(j): 5.950E-05 5.949E-05 5.948E-05 5.945E-05 5.934E-05 5.897E-05 5.794E-05 5.445E-05 U-238 Pu-242 5.400E-05 0.000E+00 8.362E-15 2.500E-14 8.230E-14 2.384E-13 7.049E-13 1.540E-12 2.197E-12 U-238 Pu-242 9.999E-01 0.000E+00 1.549E-10 4.629E-10 1.524E-09 4.415E-09 1.305E-08 2.852E-08 4.069E-08 U-238 S(j): 0.000E+00 1.549E-10 4.629E-10 1.524E-09 4.415E-09 1.305E-08 2.852E-08 4.069E-08 Pu-242 Pu-242 9.999E-01 9.999E-01 9.999E-01 9.997E-01 9.991E-01 9.973E-01 9.911E-01 9.737E-01 9.151E-01 Ru-106 Ru-106 1.000E+00 1.000E+00 2.245E-01 1.131E-02 3.251E-07 3.435E-20 0.000E+00 0.000E+00 0.000E+00 Sb-124 Sb-124 1.000E+00 1.000E+00 6.659E-03 2.952E-07 1.713E-22 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 7.720E-01 7.720E-01 2.684E-01 3.244E-02 1.991E-05 1.324E-14 0.000E+00 0.000E+00 0.000E+00 Sb-125 Sb-125 2.280E-01 2.280E-01 7.926E-02 9.580E-03 5.880E-06 3.910E-15 0.000E+00 0.000E+00 0.000E+00 Sb-125 S(j): 1.000E+00 3.476E-01 4.202E-02 2.579E-05 1.715E-14 0.000E+00 0.000E+00 0.000E+00 Te-125m Sb-125 2.280E-01 0.000E+00 8.271E-02 1.016E-02 6.237E-06 4.148E-15 0.000E+00 0.000E+00 0.000E+00 Sn-113 Sn-113 1.000E+00 1.000E+00 4.949E-02 1.212E-04 8.821E-14 6.863E-40 0.000E+00 0.000E+00 0.000E+00 Sr-90 Sr-90 1.000E+00 1.000E+00 9.709E-01 9.152E-01 7.442E-01 4.121E-01 5.208E-02 1.413E-04 1.469E-13 Tc-99 Tc-99 1.000E+00 1.000E+00 4.465E-01 8.901E-02 3.149E-04 3.122E-11 9.582E-36 0.000E+00 0.000E+00 Zn-65 Zn-65 1.000E+00 1.000E+00 1.581E-01 3.954E-03 9.775E-09 9.340E-25 0.000E+00 0.000E+00 0.000E+00

RESRAD, Version 6.5 T<< Limit = 30 days 01/10/2014 13:03 Page 56 Summary : Dresden 10CFR20.2002 Pad DCGL Evaluation File : C:\\RESRAD_FAMILY\\RESRAD\\6.5\\USERFILES\\JJC012413RECREATIONIST.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i) S(j,t), pCi/g (j) (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 Zr-95 Zr-95 1.000E+00 1.000E+00 1.912E-02 6.988E-06 6.523E-18 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Nb-95 Zr-95 1.000E+00 0.000E+00 3.339E-02 1.242E-05 1.160E-17 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.

RESCALC.EXE execution time = 117.42 seconds Total water/soil iteration failures = 1.