NRC 2002-0072, Fitness-for-Duty (FFD) Program
ML022460302 | |
Person / Time | |
---|---|
Site: | Point Beach ![]() |
Issue date: | 08/21/2002 |
From: | Webb T Nuclear Management Co |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
FOIA/PA-2006-0113, NRC 2002-0072 | |
Download: ML022460302 (3) | |
Similar Documents at Point Beach | |
---|---|
Category:Letter type:NRC
MONTHYEARNRC 2023-0013, Response to Regulatory Information Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-07-0707 July 2023
[Table view]Response to Regulatory Information Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations NRC 2023-0006, Post-Exam Submittal Cover Letter2023-03-0101 March 2023 Post-Exam Submittal Cover Letter NRC 2023-0005, Report of Changes to Emergency Plan2023-02-21021 February 2023 Report of Changes to Emergency Plan NRC 2022-0032, Sixth 10-Year Interval Inservice Testing (1ST) Program Plan2022-09-30030 September 2022 Sixth 10-Year Interval Inservice Testing (1ST) Program Plan NRC 2022-0025, License Amendment Request 295, Beacon Power Distribution Monitoring System2022-09-26026 September 2022 License Amendment Request 295, Beacon Power Distribution Monitoring System NRC 2022-0019, Report of Changes to Emergency Plan2022-07-13013 July 2022 Report of Changes to Emergency Plan NRC 2022-0022, Response to Request for Supplemental Information (Rsi) Regarding License Amendment Request (LAR) 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2,2022-07-11011 July 2022 Response to Request for Supplemental Information (Rsi) Regarding License Amendment Request (LAR) 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, NRC 2022-0015, Fall 2021 Unit 2 (U2R38) Steam Generator Tube Inspection Report2022-04-27027 April 2022 Fall 2021 Unit 2 (U2R38) Steam Generator Tube Inspection Report NRC 2022-0014, 2021 Annual Monitoring Report2022-04-14014 April 2022 2021 Annual Monitoring Report NRC 2021-0012, Core Operating Limits Report (COLR) Unit 1 Cycle 41 (U 1 C41)2022-04-0707 April 2022 Core Operating Limits Report (COLR) Unit 1 Cycle 41 (U 1 C41) NRC 2022-0003, License Amendment Request 296, Application for Technical Specification Improvement to Eliminate Requirements for Post-Accident Systems Using the Consolidated Line Item Improvement Process2022-03-25025 March 2022 License Amendment Request 296, Application for Technical Specification Improvement to Eliminate Requirements for Post-Accident Systems Using the Consolidated Line Item Improvement Process NRC 2022-0006, Notification of Deviation from Pressurized Water Owners Group (PWROG) Report WCAP-17451-P, Revision 1, Reactor Internals Guide Tube Wear - Westinghouse Domestic Fleet Operational Projections2022-02-22022 February 2022 Notification of Deviation from Pressurized Water Owners Group (PWROG) Report WCAP-17451-P, Revision 1, Reactor Internals Guide Tube Wear - Westinghouse Domestic Fleet Operational Projections NRC 2022-0004, Report of Changes to Emergency Plan2022-02-0909 February 2022 Report of Changes to Emergency Plan NRC 2022-0005, Refueling Outage U2R38 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2022-02-0101 February 2022 Refueling Outage U2R38 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2022-0001, Report of Changes to Emergency Plan2022-01-11011 January 2022 Report of Changes to Emergency Plan NRC 2021-0046, Core Operating Limits Report (COLR) Unit 2 Cycle 39 (U2C39) and Changes to Unit 1 COLR Unit 1 Cycle 40 (U1C40)2021-10-28028 October 2021 Core Operating Limits Report (COLR) Unit 2 Cycle 39 (U2C39) and Changes to Unit 1 COLR Unit 1 Cycle 40 (U1C40) NRC 2021-0031, Registration of Holtec Hi STORM Casks HI-STORM-37-054, HI-STORM-37-055, and HI-STORM-37-0562021-07-15015 July 2021 Registration of Holtec Hi STORM Casks HI-STORM-37-054, HI-STORM-37-055, and HI-STORM-37-056 NRC 2021-0027, Registration of Holtec Historm Casks HISTORM-37-051, HISTORM-37-052, and HISTORM-37-0532021-06-30030 June 2021 Registration of Holtec Historm Casks HISTORM-37-051, HISTORM-37-052, and HISTORM-37-053 NRC 2021-0028, Generic Letter 2004-02 Containment Sump Debris Transport Calculation Non-Conservatism2021-06-23023 June 2021 Generic Letter 2004-02 Containment Sump Debris Transport Calculation Non-Conservatism NRC 2021-0021, 2020 Annual Monitoring Report2021-04-29029 April 2021 2020 Annual Monitoring Report NRC 2021-0019, Response to Regulatory Information Summary 2021-01 Preparation and Scheduling of Operator Licensing Examinations2021-04-22022 April 2021 Response to Regulatory Information Summary 2021-01 Preparation and Scheduling of Operator Licensing Examinations NRC-2021-0010, CFR 50.59 Evaluation and Commitment Change Summary Report2021-04-0202 April 2021 CFR 50.59 Evaluation and Commitment Change Summary Report NRC-2021-0011, Technical Specification Bases and Technical Requirement Manual Change Summary2021-04-0202 April 2021 Technical Specification Bases and Technical Requirement Manual Change Summary NRC 2021-0006, Report of Changes to Emergency Plan2021-03-18018 March 2021 Report of Changes to Emergency Plan NRC 2021-0005, Withdrawal of Exemption Request Supporting Updated Final Response to NRC Generic Letter 2004-022021-02-11011 February 2021 Withdrawal of Exemption Request Supporting Updated Final Response to NRC Generic Letter 2004-02 NRC 2021-0002, Refueling Outage U1 R39 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2021-01-21021 January 2021 Refueling Outage U1 R39 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2021-0003, Refueling 39 (U1 R39) Reactor Coolant Pump Analytical Evaluation Report2021-01-21021 January 2021 Refueling 39 (U1 R39) Reactor Coolant Pump Analytical Evaluation Report NRC 2021-0001, Report of Changes to Emergency Plan2021-01-13013 January 2021 Report of Changes to Emergency Plan NRC 2020-0044, Response to Request for Additional Information Request for Exemption from 10 CFR 73, Appendix B, Section VI Regarding Annual Force-On-Force Exercise2020-12-0808 December 2020 Response to Request for Additional Information Request for Exemption from 10 CFR 73, Appendix B, Section VI Regarding Annual Force-On-Force Exercise NRC 2020-0032, Application for Subsequent Renewed Facility Operating Licenses2020-11-16016 November 2020 Application for Subsequent Renewed Facility Operating Licenses NRC 2020-0039, Core Operating Limits Report (COLR) Unit 1 Cycle 40 (U1 C40)2020-11-0202 November 2020 Core Operating Limits Report (COLR) Unit 1 Cycle 40 (U1 C40) NRC 2020-0031, NextEra Energy Point Beach, LLC Response to Apparent Violation in NRC Inspection Report 05000266/2020012, 05000301/2020012: EA-20-0812020-10-0505 October 2020 NextEra Energy Point Beach, LLC Response to Apparent Violation in NRC Inspection Report 05000266/2020012, 05000301/2020012: EA-20-081 NRC 2020-0029, Supplement to License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss2020-09-15015 September 2020 Supplement to License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss NRC 2020-0024, Response to Request for Additional Information Request for Exemption from Certain Operator Requalification Requirements2020-08-17017 August 2020 Response to Request for Additional Information Request for Exemption from Certain Operator Requalification Requirements NRC 2020-0020, License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss2020-08-13013 August 2020 License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss NRC 2020-0023, NextEra Energy Point Beach, LLC - Revised Response to Regulatory Information Summary 2020-01, Preparation and Scheduling of Operator Licensing Examinations2020-08-12012 August 2020 NextEra Energy Point Beach, LLC - Revised Response to Regulatory Information Summary 2020-01, Preparation and Scheduling of Operator Licensing Examinations NRC 2020-0021, Response to NRC Inspection Report and Preliminary White Finding2020-08-12012 August 2020 Response to NRC Inspection Report and Preliminary White Finding NRC 2020-0018, Report of Changes to Emergency Plan2020-07-15015 July 2020 Report of Changes to Emergency Plan NRC-2020-0016, Supplement to Exemption Request for Access Authorization and Fitness for Duty Requirements Due to COVID-19 Pandemic2020-06-12012 June 2020 Supplement to Exemption Request for Access Authorization and Fitness for Duty Requirements Due to COVID-19 Pandemic NRC 2020-0012, Refueling Outage U2R37 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2020-05-20020 May 2020 Refueling Outage U2R37 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2020-0008, Report of Changes to Emergency Plan2020-04-0606 April 2020 Report of Changes to Emergency Plan NRC 2020-0007, Core Operating Limits Report (COLR) Unit 2 Cycle 28 (U2C38)2020-03-27027 March 2020 Core Operating Limits Report (COLR) Unit 2 Cycle 28 (U2C38) NRC 2020-0003, License Amendment Request 289: Tornado Missile Protection Licensing Basis2020-02-0606 February 2020 License Amendment Request 289: Tornado Missile Protection Licensing Basis NRC 2020-0001, Pressure Temperature Limits Report (PTLR)2020-01-0909 January 2020 Pressure Temperature Limits Report (PTLR) NRC 2019-0044, Report of Changes to Emergency Plan2019-11-0101 November 2019 Report of Changes to Emergency Plan NRC 2019-0036, Submittal of 2018 Update to Final Safety Analysis Report2019-10-18018 October 2019 Submittal of 2018 Update to Final Safety Analysis Report NRC 2019-0037, Technical Specification Bases Change Summary2019-10-18018 October 2019 Technical Specification Bases Change Summary NRC 2019-0034, Technical Requirements Manual Change Summary2019-10-18018 October 2019 Technical Requirements Manual Change Summary NRC 2019-0032, CFR 50.59 Evaluation and Commitment Change Summary Report2019-10-18018 October 2019 CFR 50.59 Evaluation and Commitment Change Summary Report NRC 2019-0042, NextEra Energy Point Beach, LLC, Relief Request 1-RR-13 and 2-RR-13, Response to Request for Additional Information2019-10-17017 October 2019 NextEra Energy Point Beach, LLC, Relief Request 1-RR-13 and 2-RR-13, Response to Request for Additional Information 2023-07-07 Category:Report MONTHYEARL-2023-089, Refueling Outage Owner'S Activity Report (OAR-1) Unit 2 for Inservice Inspections2023-07-24024 July 2023
[Table view]Refueling Outage Owner'S Activity Report (OAR-1) Unit 2 for Inservice Inspections L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2022-168, and Point Beach Units 1 and 2 - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report2022-10-26026 October 2022 and Point Beach Units 1 and 2 - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report L-2020-159, 10 CFR 50.59 Evaluation and Commitment Change Summary Report2022-10-0404 October 2022 10 CFR 50.59 Evaluation and Commitment Change Summary Report L-2022-121, Exemption Request, License Amendment Request and Revised Response in Support of a Risk-informed Resolution of Generic Letter 2004-022022-07-29029 July 2022 Exemption Request, License Amendment Request and Revised Response in Support of a Risk-informed Resolution of Generic Letter 2004-02 ML22140A1432022-05-20020 May 2022 Enclosure 4 - Information Supporting Justification of Excluding Sources of Risk Not Addressed by PRA Models ML22140A1362022-05-20020 May 2022 Containment Isolation Valves ML22140A1382022-05-20020 May 2022 Containment Isolation Valves ML22140A1392022-05-20020 May 2022 Attachment 4 - Cross-Reference of TSTF-505, Revision 2, and Point Beach Proposed Changes ML22140A1402022-05-20020 May 2022 Attachment 5 - Evaluation of Plant-Specific Variations ML22140A1412022-05-20020 May 2022 Attachment 6 - Point Beach RICT Program Pre-Implementation Items ML22140A1352022-05-20020 May 2022 RPS Instrumentation ML22140A1422022-05-20020 May 2022 Enclosure 1 - List of Revised Required Actions to Corresponding PRA Functions and Additional Supporting Information ML22140A1332022-05-20020 May 2022 Attachment 1 - Evaluation of the Proposed Changes NRC 2022-0007, Enclosure 11 - Monitoring Program2022-05-20020 May 2022 Enclosure 11 - Monitoring Program ML22140A1442022-05-20020 May 2022 Enclosure 8 - Attributes of the Configuration Risk Management Model ML21214A0432021-08-0202 August 2021 SLRA June 30, 2021, Public Meeting Discussion Questions ML21126A2392021-05-0606 May 2021 Subsequent License Renewal Application, Aging Management Supplement 2 ML21040A4842021-02-0909 February 2021 Fws to NRC, Point Beach Subsequent License Renewal Updated List of Threatened and Endangered Species That May Occur in Your Proposed Project Location And/Or May Be Affected by Your Project ML21040A4852021-02-0909 February 2021 Fws to NRC, Verification Letter for Point Beach SLR Under Programmatic Biological Opinion for Northern Long-eared Bat NRC 2021-0003, Refueling 39 (U1 R39) Reactor Coolant Pump Analytical Evaluation Report2021-01-21021 January 2021 Refueling 39 (U1 R39) Reactor Coolant Pump Analytical Evaluation Report ML21008A0172020-10-25025 October 2020 Revised ANS Design Report NRC 2020-0001, Pressure Temperature Limits Report (PTLR)2020-01-0909 January 2020 Pressure Temperature Limits Report (PTLR) NRC 2019-0026, Relief Request 2-RR-17 Extension of the Primary Nozzle Dissimilar Metal (DM) Weld Inspection Interval. with LTR-SDA-19-071-NP Enclosure2019-08-29029 August 2019 Relief Request 2-RR-17 Extension of the Primary Nozzle Dissimilar Metal (DM) Weld Inspection Interval. with LTR-SDA-19-071-NP Enclosure L-2019-151, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report2019-08-0606 August 2019 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report L-2019-010, Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography for Ferritic and Austenitic Welds2019-03-19019 March 2019 Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography for Ferritic and Austenitic Welds NRC 2019-0002, Refueling Outage U2R36 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2019-01-24024 January 2019 Refueling Outage U2R36 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2018-0017, 10 CFR 50.59 Evaluation and Commitment Change Summary Report2018-05-0202 May 2018 10 CFR 50.59 Evaluation and Commitment Change Summary Report NRC 2017-0045, Updated Final Response to NRC Generic Letter 2004-022017-12-29029 December 2017 Updated Final Response to NRC Generic Letter 2004-02 NRC 2017-0037, High Frequency Seismic Evaluation Confirmation Report2017-08-0202 August 2017 High Frequency Seismic Evaluation Confirmation Report NRC 2017-0032, Focused Evaluation for Local Intense Precipitation2017-06-22022 June 2017 Focused Evaluation for Local Intense Precipitation ML17136A3222017-05-19019 May 2017 Staff Assessment of Response to 10 CFR 50.54(F) Information Request - Flood-Causing Mechanism Reevaluation L-2017-014, Florida Power & Light Company - 10 CPR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications for 20162017-04-17017 April 2017 Florida Power & Light Company - 10 CPR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications for 2016 ML17018A2712017-02-0909 February 2017 Flood Hazard Mitigation Strategies Assessment NRC 2016-0041, Submittal of 10 CFR 50.59 Summary Report for 20152016-08-31031 August 2016 Submittal of 10 CFR 50.59 Summary Report for 2015 NRC 2015-0072, Notification of Full Compliance with Order EA-12-049, Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design Basis External Events and Submittal of Final Integrated Plan2015-12-16016 December 2015 Notification of Full Compliance with Order EA-12-049, Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design Basis External Events and Submittal of Final Integrated Plan ML15300A1402015-11-0303 November 2015 Staff Assessment of Response to 10 CFR 50.54(f) Information Request - Flood-Causing Mechanism Reevaluation ML15211A5932015-08-0303 August 2015 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(F), Seismic Hazard Reevaluations for Recommendation 2.1 of the Near Term Task Force NRC 2015-0043, Spent Fuel Storage Five-Year Inspection Report Ventilated Spent Fuel Storage Cask WVSC-24-01 Certificate of Compliance 10072015-07-20020 July 2015 Spent Fuel Storage Five-Year Inspection Report Ventilated Spent Fuel Storage Cask WVSC-24-01 Certificate of Compliance 1007 NRC 2014-0041, 10 CFR 50.59 Summary Report for 20132014-08-27027 August 2014 10 CFR 50.59 Summary Report for 2013 ML14147A0342014-06-0606 June 2014 Review of the 2013 Steam Generator Tube Inspections NRC 2014-0024, NextEra Energy Point Beach, LLC - Seismic Hazard and Screening Report (CEUS Sites), Response NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the F2014-03-31031 March 2014 NextEra Energy Point Beach, LLC - Seismic Hazard and Screening Report (CEUS Sites), Response NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukush ML13338A5102014-01-27027 January 2014 Interim Staff Evaluation and Audit Report Relating to Overall Integrated Plan in Response to Order EA-12-049 - Mitigation Strategies ML14006A1872014-01-10010 January 2014 Mega-Tech Services, LLC Technical Evaluation Report Regarding the Overall Integrated Plan for Point Beach Station, Units 1 and 2, TAC Nos.: MF0725 and MF0726 NRC 2013-0069, Supporting Documentation for July 22, 2013, Regulatory Conference to Discuss Inspection Report 05000266/2013011 and 05000301/2013011, Preliminary Yellow Finding2013-07-15015 July 2013 Supporting Documentation for July 22, 2013, Regulatory Conference to Discuss Inspection Report 05000266/2013011 and 05000301/2013011, Preliminary Yellow Finding ML13193A0322013-07-11011 July 2013 Additional Equipment Height Information with Vulnerability to Flood Waters NRC 2013-0057, Filing of Owner'S Lnservice Inspection Summary Report IWE Class Mc and Iwl Class CC for Point Beach Nuclear Plant Refueling Outage U1 R342013-07-0303 July 2013 Filing of Owner'S Lnservice Inspection Summary Report IWE Class Mc and Iwl Class CC for Point Beach Nuclear Plant Refueling Outage U1 R34 NRC 2013-0061, CFR 50.59 Summary Report for 20122013-06-28028 June 2013 CFR 50.59 Summary Report for 2012 NRC 2012-0101, NextEra Energy Point Beach, LLC Response to 10 CFR 50.54(f) Request for Information Regarding Near-Term Task Force Recommendation 2.3, Seismic2012-11-26026 November 2012 NextEra Energy Point Beach, LLC Response to 10 CFR 50.54(f) Request for Information Regarding Near-Term Task Force Recommendation 2.3, Seismic NRC 2011-0059, 10 CFR 50.59 Summary Report for 20102011-07-0101 July 2011 10 CFR 50.59 Summary Report for 2010 2023-07-24 Category:Miscellaneous MONTHYEARL-2023-089, Refueling Outage Owner'S Activity Report (OAR-1) Unit 2 for Inservice Inspections2023-07-24024 July 2023
[Table view]Refueling Outage Owner'S Activity Report (OAR-1) Unit 2 for Inservice Inspections L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications ML21214A0432021-08-0202 August 2021 SLRA June 30, 2021, Public Meeting Discussion Questions ML21126A2392021-05-0606 May 2021 Subsequent License Renewal Application, Aging Management Supplement 2 ML21040A4842021-02-0909 February 2021 Fws to NRC, Point Beach Subsequent License Renewal Updated List of Threatened and Endangered Species That May Occur in Your Proposed Project Location And/Or May Be Affected by Your Project ML21040A4852021-02-0909 February 2021 Fws to NRC, Verification Letter for Point Beach SLR Under Programmatic Biological Opinion for Northern Long-eared Bat L-2019-151, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report2019-08-0606 August 2019 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report NRC 2019-0002, Refueling Outage U2R36 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2019-01-24024 January 2019 Refueling Outage U2R36 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2017-0045, Updated Final Response to NRC Generic Letter 2004-022017-12-29029 December 2017 Updated Final Response to NRC Generic Letter 2004-02 ML17136A3222017-05-19019 May 2017 Staff Assessment of Response to 10 CFR 50.54(F) Information Request - Flood-Causing Mechanism Reevaluation ML17018A2712017-02-0909 February 2017 Flood Hazard Mitigation Strategies Assessment NRC 2016-0041, Submittal of 10 CFR 50.59 Summary Report for 20152016-08-31031 August 2016 Submittal of 10 CFR 50.59 Summary Report for 2015 NRC 2015-0072, Notification of Full Compliance with Order EA-12-049, Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design Basis External Events and Submittal of Final Integrated Plan2015-12-16016 December 2015 Notification of Full Compliance with Order EA-12-049, Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design Basis External Events and Submittal of Final Integrated Plan ML15300A1402015-11-0303 November 2015 Staff Assessment of Response to 10 CFR 50.54(f) Information Request - Flood-Causing Mechanism Reevaluation ML15211A5932015-08-0303 August 2015 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(F), Seismic Hazard Reevaluations for Recommendation 2.1 of the Near Term Task Force NRC 2015-0043, Spent Fuel Storage Five-Year Inspection Report Ventilated Spent Fuel Storage Cask WVSC-24-01 Certificate of Compliance 10072015-07-20020 July 2015 Spent Fuel Storage Five-Year Inspection Report Ventilated Spent Fuel Storage Cask WVSC-24-01 Certificate of Compliance 1007 NRC 2014-0041, 10 CFR 50.59 Summary Report for 20132014-08-27027 August 2014 10 CFR 50.59 Summary Report for 2013 ML14147A0342014-06-0606 June 2014 Review of the 2013 Steam Generator Tube Inspections NRC 2014-0024, NextEra Energy Point Beach, LLC - Seismic Hazard and Screening Report (CEUS Sites), Response NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the F2014-03-31031 March 2014 NextEra Energy Point Beach, LLC - Seismic Hazard and Screening Report (CEUS Sites), Response NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukush NRC 2013-0069, Supporting Documentation for July 22, 2013, Regulatory Conference to Discuss Inspection Report 05000266/2013011 and 05000301/2013011, Preliminary Yellow Finding2013-07-15015 July 2013 Supporting Documentation for July 22, 2013, Regulatory Conference to Discuss Inspection Report 05000266/2013011 and 05000301/2013011, Preliminary Yellow Finding NRC 2013-0061, CFR 50.59 Summary Report for 20122013-06-28028 June 2013 CFR 50.59 Summary Report for 2012 NRC 2011-0059, 10 CFR 50.59 Summary Report for 20102011-07-0101 July 2011 10 CFR 50.59 Summary Report for 2010 NRC 2011-0035, Cycle 32 (U2C32) Core Operating Limits Report2011-03-23023 March 2011 Cycle 32 (U2C32) Core Operating Limits Report NRC 2010-0050, Refueling 32 Analytical Evaluation Report for the Reactor Vessel2010-04-13013 April 2010 Refueling 32 Analytical Evaluation Report for the Reactor Vessel ML1001900662010-01-14014 January 2010 Transmittal of Information to Support License Amendment Request 241, Alternative Source Term Seismic Evaluation Guidelines for HVAC Duct and Damper Systems NRC 2009-0082, Background Information to Support License Amendment Request 261, ATC Lnterim Operation and Impacts Re-Study, Appendixes B - J2009-07-14014 July 2009 Background Information to Support License Amendment Request 261, ATC Lnterim Operation and Impacts Re-Study, Appendixes B - J NRC 2009-0044, American Transmission Company - Interconnection System Impact Study Report, 106 MW Nuclear Generation Increase (53 MW Each at Point Beach Generators 1 and 2), Revision 32008-12-17017 December 2008 American Transmission Company - Interconnection System Impact Study Report, 106 MW Nuclear Generation Increase (53 MW Each at Point Beach Generators 1 and 2), Revision 3 ML0735203982007-12-0606 December 2007 License Amendment Request 256, One-Time Extension of Containment Integrated Leakage Test Interval, Revised Risk Assessment, Enclosure 3 ML0735204012007-12-0606 December 2007 License Amendment Request 256, One-Time Extension of Containment Integrated Leakage Test Interval, Impact on the Point Beach Nuclear Plant Large Early Release Frequency (LERF) Due to Level 2 Modeling Enhancements, Enclosure 4 NRC 2007-0093, Response to Request for Additional Information 10 CFR 50.55a Requests Relief Request RR-19 and RR-20 Associated with Examination of the Reactor Pressure Vessels Fourth Ten-Year Inservice Inspection Program Interval2007-11-16016 November 2007 Response to Request for Additional Information 10 CFR 50.55a Requests Relief Request RR-19 and RR-20 Associated with Examination of the Reactor Pressure Vessels Fourth Ten-Year Inservice Inspection Program Interval NRC 2007-0092, Pressure and Temperature Limits Report2007-11-15015 November 2007 Pressure and Temperature Limits Report NRC 2007-0083, Spring 2007 Unit 1 (U1R30) Steam Generator Tube Inspection Report2007-10-25025 October 2007 Spring 2007 Unit 1 (U1R30) Steam Generator Tube Inspection Report NRC 2007-0070, Fitness-For-Duty (FFD) Program Performance Data for Point Beach for January Through June 20072007-08-10010 August 2007 Fitness-For-Duty (FFD) Program Performance Data for Point Beach for January Through June 2007 ML0608600282006-02-16016 February 2006 NRC Request for Information Relating to Event Notification 42129 NRC 2006-0020, Fitness-For-Duty (FFD) Program Report2006-02-0707 February 2006 Fitness-For-Duty (FFD) Program Report NRC 2005-0128, Confirmatory Action Letter CAL 3-04-01, Excellence Plan - Revision 72005-09-30030 September 2005 Confirmatory Action Letter CAL 3-04-01, Excellence Plan - Revision 7 NRC 2005-0119, Post Accident Monitoring Instrumentation Report2005-09-16016 September 2005 Post Accident Monitoring Instrumentation Report ML0514700862005-05-24024 May 2005 Pb Breaker Report. Attach: Undated Event Investigation Report CAP056776. Attach: Event Investigation Personnel Statement NRC 2005-0060, Resolution of Safety-Related Questions Regarding Reactor Vessel Head Lift2005-05-0808 May 2005 Resolution of Safety-Related Questions Regarding Reactor Vessel Head Lift ML0626802592005-03-22022 March 2005 Event Investigation Report NRC 2005-0030, Supplement to Spring 2004 Unit 1 (Ul R28) Steam Generator Examination Report2005-03-0404 March 2005 Supplement to Spring 2004 Unit 1 (Ul R28) Steam Generator Examination Report NRC 2005-0027, Fitness-For-Duty (FFD) Program2005-02-22022 February 2005 Fitness-For-Duty (FFD) Program ML0727008492005-01-31031 January 2005 Caldon Experience in Nuclear Feedwater Flow Measurement ML0509501352004-12-24024 December 2004 Proposal for Information Collection-Cooling Water Intake Structure ML0425102832004-09-0303 September 2004 Issuance of Environmental Scoping Summary Report Associated with the Staff'S Review of the Application by Nuclear Management Company for Renewal of the Operating Licenses for Point. Beach Nuclear Plant, Units 1 and 2 NRC 2004-0087, Supplement to Owner'S Inservice Inspection Summary Report Submitted for Point Beach Nuclear Plant Unit 1 Refueling Outage U1R272004-08-26026 August 2004 Supplement to Owner'S Inservice Inspection Summary Report Submitted for Point Beach Nuclear Plant Unit 1 Refueling Outage U1R27 ML0514700632004-06-0202 June 2004 Plan-of-the-Day Meeting Handouts, with Handwritten Notes ML0514605172004-04-23023 April 2004 Condition Report, CAP055986 Evaluate Use of RP Greeter at Containment Hatches During Outage Periods with R. Alexander'S (Riii) Notes ML0514605192004-04-23023 April 2004 Event Investigation Report ML0514604942004-04-0909 April 2004 Licensee Root Cause Report, CAP55527, Industrial Safety Issues and Poor Work Practices During Nozzle Dam Installation, with R. Alexander'S (Riii) Notes 2023-07-24 |
Text
Kewaunee Nuclear Power Plant Point Beach Nuclear Plant N490 Highway 42 6610 Nuclear Road Kewaunee, Wl 54216-9511 Two Rivers, WI 54241 920 388.2560 920 755 2321 NMC Committed to Nuclear Excellence~ Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC NRC 2002-0072 10 CFR 26.71(d)
August 21, 2002 Document Control Desk U. S. Nuclear Regulatory Commission Mail Station P 1-137 Washington DC 20555 Ladies/Gentlemen:
Dockets 50-266 and 50-301 Fitness-For-Duty (FFD) Program Point Beach Nuclear Plant, Units 1 And 2 In accordance with 10 CFR 26.71(d), we are enclosing our Fitness-for-Duty performance data for the six-month period ending June 30, 2002. No events reportable in accordance with 10 CFR 26.73(a) occurred during this period.
If you have questions or require additional information, please contact us.
Sincerely, Thomas J. Webb Regulatory Affairs Manager FAF/kmd Enclosure cc: NRC Resident Inspector NRC Regional Administrator cVY NRC NRR Project Manager Kc
Fitness for Duty Program Performance Data Personnel Subject to 10 CFR 26 Nuclear Management Company, LLC June 2002 Company 6 Months Ending Point Beach Nuclear Plant Location Darlene Peters 920/755-7811 Contact Name Phone (include area code)
Cutoffs: Screen/Confirmation (ng/ml) Z Appendix A to 10 CFR 26 Marijuana / Amphetamines / /
/ I Cocaine Phencyclidine
/
/
Opiates Alcohol (% BAC)
Testing Results Licensee Employees Contractor Personnel Average Number with 827 418 Unescorted Access Categories Tested Positive Tested Positive Pre-Access 30 0 402 1 For Post accident 0 0 1 0 Cause Observed behavior 0 0 1 1 Random 244 0 67 0 Follow-up 11 0 69 0 Other 8 0 0 0 Total 293 0 540 2
Breakdown of Confirmed Positive Tests for Specific Substances Marijuana Cocaine Opiates Methamphetamines Phencyclidine Alcohol to Test 1 2 3 1 411 Licensee Employees 0 0 0 0 0 0 011 1 Contractors I 0 0 0 0 I 0 Total 1 0 0 0 0 1 0 Ii2I]I ]
On March 21, 2002, a contractor tested positive for marijuana on a pre-access drug/alcohol screen. The contractor was not allowed unescorted access and was provided an opportunity to appeal through the We Energies appeal process. The contractor did not appeal and unescorted access remains denied.
On April 2, 2002, a contractor tested positive for alcohol during a for cause (observed behavior) drug /alcohol screen. The contractor's unescorted access was suspended and the contractor was provided an opportunity to appeal through the We Energies appeal process. The contractor did not appeal and unescorted access remains denied.