Letter Sequence Other |
---|
EPID:L-2018-LLA-0292, User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14 (Approved, Closed) |
Results
Other: ML19120A057, ML19120A058, ML19120A059, ML19120A061, ML19120A062, ML19120A063, ML19120A064, ML19164A139, ML19295C569, ML19295C570, ML19295C572, ML19295C573, ML19295C574, ML19343B289
|
MONTHYEARML19015A3332019-01-24024 January 2019 Letter to J. Tomlinson Amendment No. 14 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Additional Information (W/Enclosure 1) Project stage: RAI ML19164A1392019-06-13013 June 2019 Letter to J. Tomlinson Amendment No. 14 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Updated Review Schedule Project stage: Other ML19184A0082019-07-0202 July 2019 Letter to J. Tomlinson Approval of Holtec International Request for Withholding Information from Public Disclosure - Certificate of Compliance No. 1014, Hi-Storm 100 Multipurpose Canister Storage System, Amendment Request No. 14 Project stage: Withholding Request Acceptance ML19120A0572019-07-0909 July 2019 Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14 Project stage: Other ML19120A0762019-07-0909 July 2019, 25 September 2019 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14 Project stage: Request ML19120A0582019-09-25025 September 2019 Reference 1: Proposed CoC 1014 Amendment No. 14 CoC (Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14) Project stage: Other ML19120A0592019-09-25025 September 2019 Reference 2: Proposed CoC 1014 Amendment No. 14 Appendix a (Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14) Project stage: Other ML19120A0612019-09-25025 September 2019 Reference 3: Proposed CoC 1014 Amendment No. 14 Appendix B (Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14) Project stage: Other ML19120A0622019-09-25025 September 2019 Reference 4: Proposed CoC 1014 Amendment No. 14 Appendix A-100U (Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14) Project stage: Other ML19120A0632019-09-25025 September 2019 Reference 5: Proposed CoC 1014 Amendment No. 14 Appendix B-100U (Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14) Project stage: Other ML19120A0642019-09-25025 September 2019 Reference 6: Preliminary CoC 1014 Amendment No. 14 SER (Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14) Project stage: Other ML19295C5772019-11-26026 November 2019 Letter to Holtec: Issuance of CoC 1014, Amendment No.14 Project stage: Approval ML19295C5672019-11-26026 November 2019 Issuance of Certificate of Compliance No. 1014, Amendment No. 14 for the HI-STORM 100 Multipurpose Canister Cask System (Dkt. 72-1014, CAC: 001028, EPID: L-2018-LLA-0292 Project stage: Request ML19295C5762019-11-26026 November 2019 Enclosure 6: CoC 1014, Amendment No. 14, Final Safety Evaluation Report Project stage: Approval ML19295C5742019-11-26026 November 2019 Enclosure 5: CoC 1014, Amendment No. 14, Appendix B-100U Project stage: Other ML19295C5732019-11-26026 November 2019 Enclosure 4: CoC 1014, Amendment No. 14, Appendix A-100U Project stage: Other ML19295C5722019-11-26026 November 2019 Enclosure 3: CoC 1014, Amendment No. 14, Appendix B Project stage: Other ML19295C5702019-11-26026 November 2019 Enclosure 2: CoC 1014, Amendment No. 14, Appendix a Project stage: Other ML19295C5692019-11-26026 November 2019 Enclosure 1: CoC 1014, Amendment No. 14, Certificate of Compliance Project stage: Other ML19343B2892019-12-0909 December 2019 Appendix a to Certificate of Compliance No. 1014 Amendment No. 14, as Corrected Project stage: Other 2019-06-13
[Table View] |
|
---|
Category:Memoranda
MONTHYEARML24018A0852024-01-31031 January 2024 Safety Determination of a Potential Structural Failure of the Full Basket During Accident Conditions for the HI-STORM 100 and HI-STORM Flood/Wind Dry Cask Storage Systems ML23123A1032023-12-20020 December 2023 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 16 ML23313A1172023-11-21021 November 2023 October 26, 2023 Summary of Holtec International Pre-decisional Enforcement Conference ML22313A0382022-12-19019 December 2022 Corrected User Need for Rulemaking for Amendment No. 17 to HI-STORM 100 System ML22297A1272022-10-31031 October 2022 Summary of Meeting with Holtec International to Discuss Clarification of Holtec'S Responses to Request for Additional Information for the Shielding Topical Report ML22175A0872022-08-24024 August 2022 Preliminary HI-STORM 100 Amendment 17 User Need Memo ML22207B7842022-08-0101 August 2022 Memo Meeting Summary for CoC No. 1014, Amendment No. 18 - Rsi Clarifications ML22098A2342022-04-14014 April 2022 User Need Memo for Renewal of CoC No. 1014 (HI-STORM 100 Cask System) ML21326A0812021-11-30030 November 2021 November 10, 2021, Summary of Public Meeting with Holtec International to Discuss Pre-Application of Certificate of Compliance No. 1014, Amendment No. 18 ML21237A0432021-08-25025 August 2021 Summary of July 27, 2021, Public Meeting with Holtec International to Discuss Certificate of Compliance No. 1014 for the HI-STORM 100, Amendment No. 16, Graded Approach ML21082A0852021-04-0909 April 2021 Summary of Closed Meeting with Holtec International and U.S. Nuclear Regulatory Commission Regarding Topical Report for Allowance of Heat Load Patterns in Hi-Storm 100 and Hi-Storm FW Systems ML21077A2682021-03-22022 March 2021 Summary of March 10, 2021, Public Meeting with Holtec International to Discuss Pre-Application of Shielding Method of Evaluation Topical Report ML20295A4132021-01-27027 January 2021 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 15 ML20064F6162020-02-29029 February 2020 January 15, 2020, Summary of Meeting with Holtec International, Inc., to Discuss the Upcoming Submittal of the Application for Renewal of the Storage Certificate of Compliance No. 1014 for the HI-Storm 100 Cask System ML19330E4052019-12-0404 December 2019 Holtec Thermal Topical Report Pre-application Meeting #2 Summary ML19241A2762019-08-29029 August 2019 Memorandum to C. Regan Summary of August 19, 2019, Partially Closed Public Meeting with Holtec International to Discuss Pre-Application of Thermal Topical Report (W/Enclosure) ML19120A0572019-07-0909 July 2019 Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14 ML19071A2942019-03-12012 March 2019 Regulatory History for CoC 1014 Amendment Nos. 11 and 12 ML19024A0502019-01-24024 January 2019 Summary of Partially Closed Pre-Application Meeting with Holtec International to Discuss Proposed Amendment Application to CoC No. 1014 for HI-STORM 100 Multipurpose Canister Storage System (W/Encl. 1) ML18351A1722019-01-17017 January 2019 Memorandum to K. Morgan-Butler User Need for Rulemaking for Amendment No. 13 to the Holtec International HI-STORE 100 Cask System ML18306A7682018-11-0101 November 2018 Memorandum to Y. Diaz-Sanabria Summary of October 17, 2018, Partially Closed Pre-Application Meeting with Holtec International to Discuss Proposed Amendment Application to Certificate of Compliance No. 1014 for HI-STORM 100 (W/Enclosure 1) ML18289A4132018-10-16016 October 2018 Memorandum to A. Rivera-Varona Summary of September 12, 2018, Licensing Meeting with Holtec International to Discuss Technical Topics Related to Two Amendments Applications (W/Enclosure) ML18087A0562018-05-25025 May 2018 Memorandum to K. Morgan-Butler User Need for Rulemaking for the Holtec Hi-Storm 100 Cask System, Amendment No. 12 ML17143A1552017-06-0606 June 2017 Memorandum to C. Bladey Notice of Availability of Exemption for Entergy Energy Operations, Inc., Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation ML17045A5282017-05-25025 May 2017 Memo to C. Bladey Notice of Availability of Environmental Assessment and Finding of No Significant Impact for Entergy Nuclear Operations, Inc., Vermont Yankee Nuclear Power Station, Independent Spent Fuel Storage Installation Exemption Requ ML14351A2602014-12-19019 December 2014 Memo C K Bladey Re Notice of Issuance of Exemption from Holtec Intl CoC No. 1014 Fuel Specification and Loading Conditions at Arkansas Nuclear One ISFSI ML14345B0652014-12-11011 December 2014 Memo C Bladey Re Federal Register Notice of Issuance of Environmental Assessment and Finding of No Significant Impact ANO Units 1 & 2 ISFSI 72-12 and 72-1014 ML0726300142007-09-26026 September 2007 L. Reyes Memo Direct Final Rule - HI-STORM 100, Amend 4 - EDO Pkg. - to Amend 10 CFR Part 72 List of Approved Spent Fuel Storage Casks ML0215803662002-06-0606 June 2002 Memo to R. Bellamy, RGN-I from: M. Tokar Subject: Region I Independent Spent Fuel Storage Installation Inspection Plans Attachment: Sfpo Comments to Region I Integrated Inspection Plans 2024-01-31
[Table view] |
Text
July 9, 2019 MEMORANDUM TO: June Cai, Chief Materials Rulemaking and Project Management Branch Division of Rulemaking Office of Nuclear Material Safety and Safeguards FROM: John McKirgan, Chief /RA/
Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards
SUBJECT:
USER NEED FOR RULEMAKING FOR THE HOLTEC HI-STORM 100 CASK SYSTEM, AMENDMENT NO. 14 The purpose of this communication is to request support for rulemaking activities in the Division of Spent Fuel Management (DSFM) for the following Title 10 of the Code of Federal Regulations (10 CFR) Part 72 licensing action:
- 1. Changes to 10 CFR 72.214 rule text (changes appear in bold):
Certificate Number: 1014.
Initial Certificate Effective Date: May 31, 2000.
Amendment Number 14 Effective Date: [insert 75 days from date of Federal Register publication].
Safety Analysis Report (SAR) Submitted by: Holtec International.
SAR
Title:
Final Safety Analysis Report for the HI-STORM 100 Cask System.
Docket Number: 72-1014.
Certificate Expiration Date: May 31, 2020.
Model Number: HI-STORM 100.
- 2. On October 31, 2018, as supplemented on November 6, 2018, February 28, 2019, April 5, 2019, April 23, 2019, and May 13, 2019, Holtec International (Holtec) submitted an amendment request to the U.S. Nuclear Regulatory Commission (NRC) for the HI-STORM 100 Certificate of Compliance (CoC) No. 1014. The proposed changes include the following:
- 1) Add three new loading patterns for the MPC-68M.
CONTACT: Yen-Ju Chen, NMSS/DSFM (301) 415-1018
J. Cai 2) Reduce cooling time to 1 year for all fuel types for storage in the MPC-68M.
- 3) Use damaged fuel isolator for damaged fuel stored in the MPC-68M.
- 4) Modify the description of the vents in the overpack in the CoC. Remove the word four from Section 1.b describing the air inlet and outlet vents.
- 3. The proposed CoC and technical specifications, and preliminary safety evaluation report (SER) have been placed in ADAMS (see references below) and are available for your use in the rulemaking package. DSFM will designate these documents as Official Agency Records after the Executive Director for Operations has approved the package (ADAMS Package No. ML19120A076).
The Office of the General Counsel has reviewed this memorandum with its referenced documents and has no legal objection to its contents.
Docket No. 72-1014 CAC No. 001028 EPID: L-2018-LLA-0292 ADAMS
References:
- 1. Proposed CoC 1014 Amendment No. 14 CoC (ML19120A058)
- 2. Proposed CoC 1014 Amendment No. 14 Appendix A (ML19120A059)
- 3. Proposed CoC 1014 Amendment No. 14 Appendix B (ML19120A061)
- 4. Proposed CoC 1014 Amendment No. 14 Appendix A-100U (ML19120A062)
- 5. Proposed CoC 1014 Amendment No. 14 Appendix B-100U (ML19120A063)
- 6. Preliminary CoC 1014 Amendment No. 14 SER (ML19120A064)
J. Cai
SUBJECT:
USER NEED FOR RULEMAKING FOR THE HOLTEC HI-STORM 100 CASK SYSTEM, AMENDMENT NO. 14, DOCUMENT DATE: July 9, 2019 DISTRIBUTION:
DSFM r/f ADAMS Package No.: ML19120A076 Memo: ML19120A057
- concur via email OFFICE DSFM DSFM OGC DSFM NAME YChen WWheatley* JMaltese* JMcKirgan DATE 6/12/2019 6/13/2019 7/5/2019 7/9/2019 OFFICIAL RECORD COPY