MONTHYEARML21211A6042021-07-30030 July 2021 International, HI-STORM 100 Multipurpose Canister Storage System Amendment 17 Request Project stage: Request ML21281A1322021-10-13013 October 2021 HI-STORM 100, CoC 1014, Amd. 17 Acceptance Letter Project stage: Acceptance Review ML22175A0872022-08-24024 August 2022 Preliminary HI-STORM 100 Amendment 17 User Need Memo Project stage: Other ML22313A0382022-12-19019 December 2022 Corrected User Need for Rulemaking for Amendment No. 17 to HI-STORM 100 System Project stage: Other ML22175A0792023-10-11011 October 2023 Proposed Certificate of Compliance No. 1014 Appendix a, Technical Specifications for the HI-STORM 100 Cask System Amendment No. 17 Project stage: Other ML22175A0812023-10-11011 October 2023 Proposed Certificate of Compliance No. 1014 Appendix C, Technical Specifications for the HI-STORM 100 Cask System Amendment No. 17 Project stage: Other ML22175A0822023-10-11011 October 2023 Proposed Certificate of Compliance No. 1014 Appendix D, Technical Specifications for the HI-STORM 100 Cask System Amendment No. 17 Project stage: Other ML22175A0832023-10-11011 October 2023 Proposed Certificate of Compliance No. 1014 Appendix A-100U, Technical Specifications for the HI-STORM 100 Cask System Amendment No. 17 Project stage: Other ML22175A0842023-10-11011 October 2023 Proposed Certificate of Compliance No. 1014 Appendix B-100U, Technical Specifications for the HI-STORM 100 Cask System Amendment No. 17 Project stage: Other ML22175A0862023-10-11011 October 2023 Preliminary Safety Evaluation Report for the HI-STORM 100 Cask System, Certificate of Compliance No. 1014, Amendment No. 17 Project stage: Approval ML22175A0852023-10-11011 October 2023 Proposed Certificate of Compliance No. 1014, Amendment No. 17 Project stage: Other ML23328A0222023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17, Appendix C Project stage: Other ML23328A0212023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17, Appendix B-100U Project stage: Other ML23328A0232023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17, Appendix D Project stage: Other ML23328A0202023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17, Appendix A-100U Project stage: Other ML23328A0192023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17, Appendix B Project stage: Other ML23328A0272023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17, Final Safety Evaluation Report Project stage: Approval ML23328A0062023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17 Project stage: Other ML23328A0052023-12-0505 December 2023 Issuance of Renewed Certificate of Compliance No. 1014, Amendment No. 17 for the Hi-Storm 100 Cask System (Cac/Epid 001028/L-2021-LLA-0140) Project stage: Approval ML23328A0172023-12-0505 December 2023 Renewed Certificate of Compliance No. 1014, Amendment No. 17, Appendix a Project stage: Other 2022-12-19
[Table View] |
|
---|
Category:Memoranda
MONTHYEARML24018A0852024-01-31031 January 2024 Safety Determination of a Potential Structural Failure of the Full Basket During Accident Conditions for the HI-STORM 100 and HI-STORM Flood/Wind Dry Cask Storage Systems ML23123A1032023-12-20020 December 2023 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 16 ML23313A1172023-11-21021 November 2023 October 26, 2023 Summary of Holtec International Pre-decisional Enforcement Conference ML22313A0382022-12-19019 December 2022 Corrected User Need for Rulemaking for Amendment No. 17 to HI-STORM 100 System ML22297A1272022-10-31031 October 2022 Summary of Meeting with Holtec International to Discuss Clarification of Holtec'S Responses to Request for Additional Information for the Shielding Topical Report ML22175A0872022-08-24024 August 2022 Preliminary HI-STORM 100 Amendment 17 User Need Memo ML22207B7842022-08-0101 August 2022 Memo Meeting Summary for CoC No. 1014, Amendment No. 18 - Rsi Clarifications ML22098A2342022-04-14014 April 2022 User Need Memo for Renewal of CoC No. 1014 (HI-STORM 100 Cask System) ML21326A0812021-11-30030 November 2021 November 10, 2021, Summary of Public Meeting with Holtec International to Discuss Pre-Application of Certificate of Compliance No. 1014, Amendment No. 18 ML21237A0432021-08-25025 August 2021 Summary of July 27, 2021, Public Meeting with Holtec International to Discuss Certificate of Compliance No. 1014 for the HI-STORM 100, Amendment No. 16, Graded Approach ML21082A0852021-04-0909 April 2021 Summary of Closed Meeting with Holtec International and U.S. Nuclear Regulatory Commission Regarding Topical Report for Allowance of Heat Load Patterns in Hi-Storm 100 and Hi-Storm FW Systems ML21077A2682021-03-22022 March 2021 Summary of March 10, 2021, Public Meeting with Holtec International to Discuss Pre-Application of Shielding Method of Evaluation Topical Report ML20295A4132021-01-27027 January 2021 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 15 ML20064F6162020-02-29029 February 2020 January 15, 2020, Summary of Meeting with Holtec International, Inc., to Discuss the Upcoming Submittal of the Application for Renewal of the Storage Certificate of Compliance No. 1014 for the HI-Storm 100 Cask System ML19330E4052019-12-0404 December 2019 Holtec Thermal Topical Report Pre-application Meeting #2 Summary ML19241A2762019-08-29029 August 2019 Memorandum to C. Regan Summary of August 19, 2019, Partially Closed Public Meeting with Holtec International to Discuss Pre-Application of Thermal Topical Report (W/Enclosure) ML19120A0572019-07-0909 July 2019 Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 14 ML19071A2942019-03-12012 March 2019 Regulatory History for CoC 1014 Amendment Nos. 11 and 12 ML19024A0502019-01-24024 January 2019 Summary of Partially Closed Pre-Application Meeting with Holtec International to Discuss Proposed Amendment Application to CoC No. 1014 for HI-STORM 100 Multipurpose Canister Storage System (W/Encl. 1) ML18351A1722019-01-17017 January 2019 Memorandum to K. Morgan-Butler User Need for Rulemaking for Amendment No. 13 to the Holtec International HI-STORE 100 Cask System ML18306A7682018-11-0101 November 2018 Memorandum to Y. Diaz-Sanabria Summary of October 17, 2018, Partially Closed Pre-Application Meeting with Holtec International to Discuss Proposed Amendment Application to Certificate of Compliance No. 1014 for HI-STORM 100 (W/Enclosure 1) ML18289A4132018-10-16016 October 2018 Memorandum to A. Rivera-Varona Summary of September 12, 2018, Licensing Meeting with Holtec International to Discuss Technical Topics Related to Two Amendments Applications (W/Enclosure) ML18087A0562018-05-25025 May 2018 Memorandum to K. Morgan-Butler User Need for Rulemaking for the Holtec Hi-Storm 100 Cask System, Amendment No. 12 ML17143A1552017-06-0606 June 2017 Memorandum to C. Bladey Notice of Availability of Exemption for Entergy Energy Operations, Inc., Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation ML17045A5282017-05-25025 May 2017 Memo to C. Bladey Notice of Availability of Environmental Assessment and Finding of No Significant Impact for Entergy Nuclear Operations, Inc., Vermont Yankee Nuclear Power Station, Independent Spent Fuel Storage Installation Exemption Requ ML14351A2602014-12-19019 December 2014 Memo C K Bladey Re Notice of Issuance of Exemption from Holtec Intl CoC No. 1014 Fuel Specification and Loading Conditions at Arkansas Nuclear One ISFSI ML14345B0652014-12-11011 December 2014 Memo C Bladey Re Federal Register Notice of Issuance of Environmental Assessment and Finding of No Significant Impact ANO Units 1 & 2 ISFSI 72-12 and 72-1014 ML0726300142007-09-26026 September 2007 L. Reyes Memo Direct Final Rule - HI-STORM 100, Amend 4 - EDO Pkg. - to Amend 10 CFR Part 72 List of Approved Spent Fuel Storage Casks ML0215803662002-06-0606 June 2002 Memo to R. Bellamy, RGN-I from: M. Tokar Subject: Region I Independent Spent Fuel Storage Installation Inspection Plans Attachment: Sfpo Comments to Region I Integrated Inspection Plans 2024-01-31
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 23, 2022 MEMORANDUM TO: Jill Shepard, Acting Chief Rulemaking and Project Management Branch Division of Rulemaking, Environmental, and Financial Support Office of Nuclear Material Safety and Safeguards Signed by Diaz-Sanabria, Yoira FROM: Yoira K. Diaz-Sanabria, Chief on 08/23/22 Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards
SUBJECT:
USER NEED FOR RULEMAKING FOR AMENDMENT NO. 17 TO HI-STORM 100 SYSTEM The purpose of this communication is to request support for rulemaking activities in the Division of Fuel Management (DFM) for the following Title 10, Code of Federal Regulations (10 CFR)
Part 72 licensing action:
- 1. Changes to 10 CFR 72.214 rule text (changes appear in bold):
Certificate Number: 1014.
Initial Certificate Effective Date: June 13, 2011.
Amendment Number 17 Effective Date: [Date, Month day, year (e.g., 2022)] [insert 75 days from date of Federal Register publication].
Amendment Number 17 Effective Date: TBD Safety Analysis Report (SAR) Submitted by: Holtec International.
SAR
Title:
Final Safety Analysis Report for the HI-STORM 100 System.
Docket Number: 72-1014.
Certificate Expiration Date: June 12, 2031.
Model Number: HI-STORM 100 Storage System.
CONTACT: Chris Allen, NMSS/DFM (301) 415-6877
J. Shepard 2
- 2. Use the following text for the purpose and scope of the amendment:
On July 30, 2021, Holtec International (the applicant) submitted an application to amend the HI-STORM 100 System. The amendment includes the following changes:
- a. update the HI-STORM 100 system description in the CoC to clearly indicate that only the portions of the components that contact the pool water need to be made of stainless steel or aluminum; and
- b. other changes to incorporate minor editorial and formatting changes.
- 3. The proposed certificate of compliance (CoC) and technical specifications (TS), and preliminary safety evaluation report (PSER) have been placed in the Agencywide Documents Access and Management System (ADAMS) (see ADAMS references below) and are available for your use in the rulemaking package. The DFM staff will designate these documents as Official Agency Records after the Executive Director for Operations has approved the package (ADAMS Package Accession No. ML22175A078).
The Office of the General Counsel has reviewed this memorandum with its referenced documents and has no legal objection to its contents.
CAC No. 001028 Docket No. 72-1014 EPID No. L-2021-LLA-0140 ADAMS
References:
- 1. Proposed CoC No. 1014, Amendment 17 (ADAMS Accession No. ML22175A085)
- 2. Proposed TS, Appendix A, CoC No. 1014, Amendment 17 (ADAMS Accession No. ML22175A079)
- 3. Proposed TS, Appendix B, CoC No. 1014, Amendment 17 (ADAMS Accession No. ML22175A080)
- 4. Proposed TS, Appendix C, CoC No. 1014, Amendment 17 (ADAMS Accession No. ML22175A081)
- 5. Proposed TS, Appendix D, CoC No. 1014, Amendment 17 (ADAMS Accession No. ML22175A082)
- 6. Proposed TS, Appendix A-100U, CoC No. 1014, Amendment 17 (ADAMS Accession No. ML22175A083)
- 7. Proposed TS, Appendix B-100U, CoC No. 1014, Amendment 17 (ADAMS Accession No. ML22175A084)
- 8. Preliminary SER (ADAMS Accession No. ML22175A086)
ML22175A078 (Pkg), ML22175A087 (Memo),
ML22175A085 (CoC), ML22175A079 (App A), ML22175A080 (App B),
ML22175A081 (App C), ML22175A082 (App D), ML22175A083 (AppA-100U)
ML22175A084 (AppB-100U), ML22175A086 (PSER)
OFFICE DFM DFM DFM DFM NAME WAllen WWheatley LHowe JColaccino DATE 7/1/22 7/11/22 7/5/22 7/27/22 OFFICE OGC DFM NAME BHarris YDiaz-Sanabria DATE 8/10/22 8/23/22
ML22175A078; Memo ML22175A087 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/MSB NRR/DEX/ESEB NAME WAllen WA WWheatley WW LHowe LH JColaccino JC DATE Jul 1, 2022 Jul 11, 2022 Jul 5, 2022 Jul 27, 2022 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NAME YDiaz-Sanabria YD YDiaz-Sanabria YD DATE Aug 5, 2022 Aug 23, 2022