MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI 2018-01-10
[Table View] |
Text
www.holtec.com HI-STORM 100 Amendment 18 RSI Clarification Meeting ATTACHMENT 1 TO HOLTEC LETTER 5014847 1 of 11
www.holtec.comlPage2 RSI 4-1 RSIasksformoredescriptionabouttheflowchartaddedinFigure 1.0.1oftheSARandspecificallyaboutthelimitationsintheSEforthe topicalreport HoltecunderstandsthatthetopicalreporthasSElimitations,but wantedtofindawaytonotsupersedethe10CFR72.48regulation whichappliestotheFSAR Holtechasaproposaltomodify,suchthatthefinalqualificationofany heatloadpatternisperformedusingtheinvarianttopicalreport model Previouslytheplanwastoshowthatthe72.48modelwasbounded bythetopicalreportmodel,andusethe72.48modelfor qualificationofheatloadpatterns Revisedproposedapproachwillshowthe72.48modelisbounded bythetopicalreportmodelandusethetopicalreportmodeltodothe finalqualificationoftheheatloadpatterns ATTACHMENT 1 TO HOLTEC LETTER 5014847 2 of 11
www.holtec.comlPage3 RSI 4-1 Step1-SitedecidestheexistingCoCheatloadpatterns donotmeettheirneeds,anddevelopsanewpattern thatwouldmeetfuelloadingneeds Step2-Site/Holtecdetermineifthesystembeing usedmatchestheinvariantmodelinthetopicalreport Ifyes,thenproceedthroughthequalificationprocess outlinedinthetopicalreport,ensureallTopicalReport acceptancecriteriaaremet,andrejoinatStep3 Ifno,followSteps2athrough2d NOTE-thesystembeingusedmuststillfallunderonethose listedintheTopicalReportSE,justmayhavesomevariation withinthosemodels ATTACHMENT 1 TO HOLTEC LETTER 5014847 3 of 11
www.holtec.comlPage4 RAI 4-1 Step2a-Ensurethatthevariationsfromthetopicalreport invariantmodel(identifiedinStep2)areacceptablewithout NRCapprovalundertheexistingCoC/FSAR ThisprocessisidenticaltoHoltecsexisting72.48programand shouldbedocumentedaccordingly,whichdevelopsa72.48 modelforthatvariation Ifnotacceptable,submittoNRCforapproval Step2b-Oncethevariationshavebeendetermined acceptableunder72.48,thesitescandidateheatloadpattern shouldbeevaluatedinthe72.48model Thiscalculationmustshowthatallcomponentshavealower temperaturethantheFSARlimitsandpressureslowerthanthe FSARlimits ThePCTfromthisanalysisisthencomparedtoStep2c ATTACHMENT 1 TO HOLTEC LETTER 5014847 4 of 11
www.holtec.comlPage5 RSI 4-1 Step2c-Thecandidateheatloadpatternisthenfully qualifiedforusebyevaluationintheTopicalReportinvariant model ThisevaluationmustshowALLTopicalReportacceptancecriteria aremet ThisevaluationmustshowahigherPCTthanStep2b Ifeitheroftheseconditionsisnotmetthecandidateheatload patternmustberevised Step2d-ThetemperatureresultsfromSteps2band2care comparedtothestructuralevaluationsintheFSAR IfFSARstructuralevaluationsusetemperaturesthatboundthe calculatedtemperatures,nofurtheraction IfFSARstructuralevaluationsusetemperaturesthatdoNOT boundthecalculatedtemperatures,anadditional72.48mustbe performedtodemonstratethenewtemperaturesareacceptable withoutNRCapproval ATTACHMENT 1 TO HOLTEC LETTER 5014847 5 of 11
www.holtec.comlPage6 RSI 4-1 Step3-OncealltheitemsandacceptancecriteriainStep2a through2daresatisfied-documenttheevaluationperformedin Step2c(candidateheatloadpatternininvariantmodel)insites qualificationreport Note,otherevaluationswillbedocumented,butofficialqualification andcomparisonwithtopicalreportacceptancecriteriaareperthe invariantmodel Thiswillbeanindividualreportforeachsiteandpossiblymorethanone reportforeachsite,soitseemsmoreappropriatetobereferencedin the72.212insteadoftheCoC Step4-Sitechoosesfueltomeetthequalifiedheatloadpattern, confirmingthatthefuelalsomeetsotherCoCrestrictions,suchas (butnotlimitedto)fueltypesandFQTs Step5-Siteensuresloadingprocedureshavetheaccurate restrictions(suchasheliumbackfillandventtemperature monitoringrequirements)basedonthetopicalreportmethodology ATTACHMENT 1 TO HOLTEC LETTER 5014847 6 of 11
www.holtec.comlPage7 RSI 4-1 Step1-Site developscandidate heatloadpattern Step2-doesthe systembeingused atsitematchthe TRinvariantmodel Step3 Evaluatethe candidateheatloadpattern underthetopicalreport methodologyanddocument inqualificationreport,with alllimitations(backfill,etc.)
Yes No Step2a-Ensurethatthe variationsidentifiedin Step2areacceptable undertheexisting CoC/FSARunder72.48,if notprocessstops Step2b-Usethemodel developedforthe72.48to evaluatethesitescandidate heatloadpattern-acceptancecriteriaare temperaturesandpressures lowerthanFSARlimit,AND PCTlowerthanStep2c Step2c-Usethetopical reporttoevaluatethesites candidateheatloadpattern
- acceptancecriteriaareas outlinedinthetopical report,andPCTmustbe higherthanStep2b Step2d-comparethe boundingtemperaturesof eachcomponentfrom2band 2ctothoseusedintheFSAR structuralanalysis,andupdate structuralanalysisifneeded/
permittedunder72.48 Step4-Sitechoosesfuelto meetthequalifiedheatload patternconfirmingthatthefuel alsomeetsotherCoC restrictions,suchasFQT Step5-Siteensuresloading procedureshavetheaccurate restrictionsbasedonthe topicalreportmethodology ATTACHMENT 1 TO HOLTEC LETTER 5014847 7 of 11
www.holtec.comlPage8 Shielding RSIs 61 DonotintendtoapplytopicalreporttoUVH,willupdateCoCforclarity AsksaboutlanguageonFSARpage51aboutessentiallyidentical Thatlanguagewasnotmodifiedinthisamendment ThelanguageremainsunchangedsinceFSARRev1in2003 AsksaboutBECTs,Section1.0.3.1oftheproposedamendmentexplains thattheexistingBECTsapplyevenwithnewheatloadpatterns developed-thisisechoedintheproposedCoC,AppB,Section2.4.3 Asksabouttheshieldinganalysisforthe100UVH,whichisunderreview aspartofAmendment16,theMLnumberisnotpubliclyavailable,but appearstobefortheAmendment16submittal 62 Asksabouttheshieldinganalysisforthe100UVH,whichisunderreview aspartofAmendment16 Amendment18didnotincludeanypatternswithdifferentzonesor modificationstoTable2.1.30towhichtheRSIrefers ATTACHMENT 1 TO HOLTEC LETTER 5014847 8 of 11
www.holtec.comlPage9 Shielding RSIs/ Observations 63 AsksaboutcomparisonofdoseratesbetweendifferentMPCsinthe100SVersionB ThereferencedMLnumberisforthebiennialFSARsubmittal,nottheAmendment18 package NochangesweremadetothissectioninAmd18,itappearsunchangedsinceFSARRev7 in2008,andrelatedevaluationswerediscussedintheSERforAmd5 ObsSh1 AsksaboutCoCheatloadpatternsvsshieldinganalysisofHISTORM100UVH ThereferencedMLisnotpubliclyavailable,butitappearstobethecalcpackage submittedwithAmd16,wheretheUVHwasintroduced NodecayheatloadpatternsintheCoChavebeenmodifiedinAmd18 ObsSh2 AsksaboutstatementsinFSARChapter5relatedtoBPRAs ReferencedMListheHISTORM100biennialsubmittal,notasectionimpactedbyAmd18 ReferencedstatementsareunchangedsinceFSARRev13in2016,andevaluationsare describedasacceptableintheSERforAmd8Rev1 ATTACHMENT 1 TO HOLTEC LETTER 5014847 9 of 11
www.holtec.comlPage10 Shielding Observations ObsSh3 Asksaboutdemonstratingthatshieldingcalculationsarereliable NoshieldingcalculationsweresubmittedwithAmd18.We wouldlikesomeclarificationontheintendedscopeofthis observation ObsSh4 AsksaboutdistancefromISFSItocontrolledareaboundary ReferstotheHISTORM100UVHshieldinganalysis,whichwas submittedinAmd16andstatementsintheFSARbiennial submittalthatareunchangedwiththisAmd18 ATTACHMENT 1 TO HOLTEC LETTER 5014847 10 of 11
www.holtec.comlPage11 Path Forward Basedonoutcomeofthismeeting,Holtecwillnotify theNRCstaffofaplannedscheduleforformal responsestotheRSIs ATTACHMENT 1 TO HOLTEC LETTER 5014847 11 of 11