ND-21-1129, ITAAC Closure Notification on Completion of ITAAC Item 2.2.03.1O (Index Number 206)

From kanterella
(Redirected from ML22067A253)
Jump to navigation Jump to search

ITAAC Closure Notification on Completion of ITAAC Item 2.2.03.1O (Index Number 206)
ML22067A253
Person / Time
Site: Vogtle 
Issue date: 03/08/2022
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ITAAC 2.2.03.10, ND-21-1129
Download: ML22067A253 (12)


Text

>-. Southern Nuclear MAR O 8 2022 Docket No.:

52-025 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 7825 River Road Waynesboro, GA 30830 706-848-6459 ND-21-1129 1 O CFR 52.99(c)(1)

ITAAC Closure Notification on Completion of ITAAC Item 2.2.03.1 O (Index Number 2061 Ladies and Gentlemen:

In accordance with 1 O CFR 52.99(c)(1 ), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP)

Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.2.03.10 (Index Number 2061. This ITAAC confirms that for Passive Core Cooling System (PXS); specified displays can be retrieved in the Main Control Room (MCR), specified controls in the MCR operate remotely operated valves and that valves function as required. The closure process for this ITAAC is based on the guidance described in Nuclear Energy Institute (NEI) 08-01,

"Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This lstter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) request NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 1 O CFR 52.99.

If there are any questions, please contact Kelli Roberts at 706-848-6991.

Respectfully submitted, Michael J. Yox Regulatory Affairs Di ector Vogtle 3 & 4

Enclosure:

MJY/DCH/sfr Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.2.03.1 O (Index Number 2061

U.S. Nuclear Regulatory Commission ND-21-1129 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena Ill Mr. D. L. McKinney Mr. H. Nieh Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. J.B. Williams Mr. M. J. Yox Mr. A. S. Parton Ms. K. A. Roberts Ms. J.M. Coleman Mr. C. T. Defnall Mr. C. E. Morrow Mr. K. J. Drudy Mr. J. M. Fisher Mr. R. L. Beilke Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 Nuclear Regulatory Commission Ms. M. Bailey Mr. M. King Mr. G. Bowman Ms. A. Veil Mr. C. P. Patel Mr. G. J. Khouri Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. J. Gaslevic Mr. 0. Lopez-Santiago Mr. G. Armstrong Mr. M. Webb Mr. T. Fredette Mr. C. Santos Mr. B. Davis Mr. J. Vasquez Mr. J. Eargle Mr. T. Fanelli Ms. K. Mccurry Mr. J. Parent Mr. B. Griman Mr. V. Hall

U.S. Nuclear Regulatory Commission ND-21-1129 Page 3 of 3 Oglethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros Westinghouse Electric Company, LLC Dr. L. Oriani Mr. D. C. Durham Mr. M. M. Corletti Mr. Z. S. Harper Mr. J. L. Coward Other Mr. S. W. Kline, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GOS Associates, Inc.

Mr. S. Roetger, Georgia Public Service Commission Mr. R. L. Trokey, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 1 of 9 Southern Nuclear Operating Company ND-21-1129 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC Item 2.2.03.1 O [Index Number 206]

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 2 of 9 ITAAC Statement Design Commitment

10. Safety-related displays of the parameters identified in Table 2.2.3-1 can be retrieved in the MCR.

11.a) Controls exist in the MCR to cause the remotely operated valves identified in Table 2.2.3-1 to perform their active function(s).

11.b) The valves identified in Table 2.2.3-1 as having PMS control perform their active function after receiving a signal from the PMS.

12.b) After loss of motive power, the remotely operated valves identified in Table 2.2.3-1 assume the indicated loss of motive power position.

13. Displays of the parameters identified in Table 2.2.3-3 can be retrieved in the MCR.

Inspections/Tests/ Analyses Inspection will be performed for the retrievability of the safety-related displays in the MCR.

ii) Stroke testing will be performed on remotely operated valves other than squib valves identified in Table 2.2.3-1 using the controls in the MCR.

ii) Testing will be performed on the remotely operated valves other than squib valves identified in Table 2.2.3-1 using real or simulated signals into the PMS.

iii) T8sting will be performed to demo1 strate that remotely operated PXS isolation valves PXS-V014A/B, V015A/B, V108A/B open within the required response times.

Testing of the remotely operated valves will be performed under the conditions of loss of motive power.

Inspection will be performed for retrievability of the displays identified in Table 2.2.3-3 in the MCR.

Acceptance Criteria Safety-related displays identified in Table 2.2.3-1 can be retrieved in the MCR.

ii) Controls in the MCR operate to cause remotely operated valves other than squib valves to perform their active functions.

ii) Remotely operated valves other than squib valves perform the active function identified in the table after a signal is input to the PMS.

iii) These valves open within 20 seconds after receipt of an actuation signal.

After loss of motive power, each remotely operated valve identified in Table 2.2.3-1 assumes the indicated loss of motive power position.

Displays identified in Table 2.2.3-3 can be retrieved in the MCR.

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 3 of 9 ITAAC Determination Basis Multiple ITAAC are performed to verify by inspections and tests that:

Safety-related displays of the parameters identified in the Combined License (COL)

Table 2.2.3-1 (Attachment A) can be retrieved in the Main Control Room (MCR).

Controls exist in the MCR to cause the remotely operated valves identified in COL Table 2.2.3-1 (Attachment B) to perform their active function(s).

The valves identified in Table 2.2.3-1 (Attachment C) as having Protection and Safety Monitoring System (PMS) control perform their active function after receiving a signal from the PMS.

Remotely operated PXS isolation valves PXS-V014A/B, V015A/B, V108A/B open within the required response times. (Attachment D)

After loss of motive power, the remotely operated valves identified in COL Table 2.2.3-1 (Attachment E) assume the indicated loss of motive power position.

Displays of the parameters identified in COL Table 2.2.3-3 (Attachment F) can be retrieved in the MCR.

Safety-related displays identified in Table 2.2.3-1 can be retrieved in the MCR.

Inspections performed in accordance with the Unit 3 component test packages listed in Reference 1, visually confirmed that when each of the displays of the plant parameter identified in Attachment A was summoned using the MCR PMS Visual Display Units (VDUs), the expected display appeared on the PMS VDU.

The completed inspection results in Reference 1 confirms that safety-related displays identified in Table 2.2.3-1 can be retrieved in Unit 3 MCR.

ii) Controls in the MCR operate to cause remotely operated valves other than squib valves to perform their active functions.

Using Plant Control System (PLS) controls in the MCR, stroke testing each valve in Attachment B was performed in accordance with Unit 3 component test packages listed in Reference 2. Each valve was stroked to its active function and proper valve position indication was verified locally and in the MCR.

This testing demonstrated PLS controls in the MCR operate to cause the remotely operated valves identified in COL Appendix C Table 2.2.3-1 to perform their active functions.

The completed test results in Reference 2 confirms that controls in the Unit 3 MCR operated to cause the remotely operated valves identified in Table 2.2.3-1 to perform active functions.

ii) Remotely operated valves other than squib valves perform the active function identified in the table after a signal is input to the PMS.

Testing was performed in accordance with Unit 3 component test packages listed in Reference 3 to confirm that the remotely operated valves other than squib valves performed the active function identified in Attachment C after a signal is input to the PMS.

The component test packages established initial conditions with each valve verified locally and in the MCR to be in the required position. An actuation signal was generated by PMS using the PMS Maintenance and Test Panel (MTP) to generate a signal to cause the valves in Attachment C to transfer to the active function position and each valve was verified locally and in the MCR.

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 4 of 9 The completed test results in Reference 3 confirmed the remotely operated valves other than squib valves perform the active function identified in the table after a signal is input to the PMS for Unit 3.

iii) These valves open within 20 seconds after receipt of an actuation signal.

Testing was performed in accordance with Unit 3 component test packages listed in Reference 3 to confirm that remotely operated PXS isolation valves PXS-V014A/B, V015A/B, V108A/B opened within 20 seconds after receipt of an actuation signal.

The component test packages established initial conditions with each valve verified locally and in the MCR to be in the closed position and a digital trend was established to time the valve actuation. An actuation signal was generated by PMS using the PMS Maintenance and Test Panel (MTP) to generate a signal to cause the valves in Attachment D to transfer open and each valve is verified locally and in the MCR.

The completed test results in Reference 3 confirm that remotely operated PXS isolation valves PXS-V014A/B, V015A/B, V108A/B opened within 20 seconds after receipt of an actuation signal for Unit 3 and the test results are documented in Attachment D.

After loss of motive power, each remotely operated valve identified in Table 2.2.3-1 assumes the indicated loss of motive power position.

Testing was performed in accordance with Unit 3 component test packages listed in Reference 4 to verify that each remotely operated valve identified in Attachment E assumed the indicated loss of motive power position upon a loss of motive power.

Testing was performed on the Motor-Operated Valves (MOVs) listed in Attachment Eby ensuring each MOV was in their pretest position of closed. Each MOV was stroked open by using the valve control circuit to de-energize the contactors, which removed motive power from the valve when the open position was reached. This loss of power caused by the valve control circuit demonstrated the MOV failed "As-ls" (Open) when motive power was removed. Actual valve position was verified locally and in the MCR. Each MOV was also stroked Closed by using the valve control circuit to de-energize the contactors, which removed motive power from the valve when the Closed position was reached. This loss of power caused by the valve control circuit demonstrated that each MOV failed "As-ls" (Closed) when motive power was removed. Actual valve position was verified locally and in the MCR.

Testing on the air operated valves listed in Attachment E was performed by placing the valves in a position opposite their loss of motive power position and opening the power supply to their air supply solenoid. This caused the solenoid to de-energize which closed the air supply to the valve and opened a vent port to vent off the air in the actuator. The valves were verified locally and in the MCR to transfer to their loss of motive power position.

The motive power for the squib valves is a single-use explosive device powered by Direct Current (DC)

Power. By design, this configuration results in the squib valves maintaining their as-is position upon a loss of motive power, as power is required to ignite the explosive device which repositions the valve.

As a result, no loss of motive power testing is required for the squib valves. Functional testing of the squib valve actuation circuits is performed by other ITAAC.

The completed test results in Reference 4 confirms that after loss of motive power, each remotely operated valve identified in Table 2.2.3-1 assumes the indicated loss of motive power position for Unit 3.

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 5 of 9 Displays identified in Table 2.2.3-3 can be retrieved in the MCR.

An inspection was performed in accordance with the Unit 3 component test package listed in Reference 1 to confirm displays identified in Attachment F can be retrieved in the MCR.

Testing was performed at an operator workstation by navigating to several PXS system screens, locating the items identified in Attachment F, and ensuring the items identified can be retrieved in the MCR.

The completed test results in Reference 1 confirms that the displays identified in Table 2.2.3-3 can be retrieved in the Unit 3 MCR.

References 1 through 4 are available for NRC inspection as part of Unit 3 ITAAC Completion Package (Reference 5).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion, Southern Nuclear Operating Company (SNC) performed a review of findings pertaining to the subject ITAAC and associated corrective actions. This review found there are no relevant IT AAC findings associated with this ITAAC. The ITAAC completion review is documented in the ITAAC Completion Package for ITAAC 2.2.03.10 Unit 3 (Reference 5) and is available for NRC review.

IT AAC Completion Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 2.2.03.10 was performed for VEGP Unit 3 and that the prescribed acceptance criteria are met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

References (available for NRC inspection)

1. SV3-PXS-ITR-800206, Rev. 0, "Unit 3 Inspection Results of: ITAAC 2.2.03.10 (Items 10 and 13)

NRC Index Number: 206"

2. SV3-PXS-ITR-801206, Rev. 0, "Unit 3 Testing Results of: ITAAC 2.2.03.1 O (Item 11.a) NRC Index Number: 206"
3. SV3-PXS-ITR-802206, Rev. 0, "Unit 3 Inspection Results of: ITAAC 2.2.03.1 O (Item 11.b) NRC Index Number:206"
4. SV3-PXS-ITR-803206, Rev. 0, "Unit 3 Recorded Results of Remotely Operated PXS Valves Response to Loss of Motive Power: ITAAC 2.2.03.10 Item 12.b)

NRC Index Number: 206"

5. 2.2.03.10-U3-CP-Rev0, "ITAAC Completion Package"

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 6 of 9 Attachment A

  • Excerpt from COL Appendix C Table 2.2.3-1 Table 2.2.3-1
  • Equipment Name
  • TaQ No.

CMT A Inlet Isolation Motor-operated Valve PXS-PL-V002A CMT B Inlet Isolation Motor-operated Valve PXS-PL-V002B CMT A Discharge Isolation Valve PXS-PL-V014A CMT B Discharge Isolation Valve PXS-PL-V014B CMT A Discharqe Isolation Valve PXS-PL-V015A CMT B Discharqe Isolation Valve PXS-PL-V015B NitroQen Supply Containment Isolation Valve PXS-PL-V042 PRHR HX Inlet Isolation Motor-operated Valve PXS-PL-V101 PRHR HX Control Valve PXS-PL-V108A PRHR HX Control Valve PXS-PL-V108B Containment Recirculation A Isolation PXS-PL-V117A Motor-operated Valve Containment Recirculation B Isolation PXS-PL-V117B Motor-operated Valve Containment Recirculation A Squib Valve PXS-PL-V118A Containment Recirculation B Squib Valve PXS-PL-V118B Containment Recirculation A Squib Valve PXS-PL-V120A Containment Recirculation B Squib Valve PXS-PL-V120B IRWST Injection A Squib Valve PXS-PL-V123A IRWST Injection A Squib Valve PXS-PL-V123B IRWST Injection A Squib Valve PXS-PL-V125A IRWST Injection A Squib Valve PXS-PL-V125B IRWST Gutter Isolation Valve PXS-PL-V130A IRWST Gutter Isolation Valve PXS-PL-V130B CMT A Level Sensor PXS-011A CMT A Level Sensor PXS-011 B CMT A Level Sensor PXS-011 C CMT A Level Sensor PXS-011 D CMT B Level Sensor PXS-012A CMT B Level Sensor PXS-012B CMT B Level Sensor PXS-012C CMT B Level Sensor PXS-012D CMT A Level Sensor PXS-013A CMT A Level Sensor PXS-013B CMT A Level Sensor PXS-013C CMT A Level Sensor PXS-013D CMT B Level Sensor PXS-014A CMT B Level Sensor PXS-014B CMT B Level Sensor PXS-01 4C CMT B Level Sensor PXS-01 4D I RWST Wide RanQe Level Sensor PXS-046 IRWST Wide Range Level Sensor PXS-047 I RWST Wide RanQe Level Sensor PXS-048 PRHR HX Flow Sensor PXS-049A

  • Safety-Related Displav Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 7 of 9 Attachment A

  • Excerpt from COL Appendix C Table 2.2.3-1 Table 2.2.3-1
  • Equipment Name
  • TaCI No.

PRHR HX Flow Sensor PXS-049B Containment Flood-up Level Sensor PXS-050 Containment Flood-up Level Sensor PXS-051 Containment Flood-up Level Sensor PXS-052 IRWST Lower Narrow Ranqe Level Sensor PXS-066 I RWST Lower Narrow Ranqe Level Sensor PXS-067 I RWST Lower Narrow Range Level Sensor PXS-06B I RWST Lower Narrow Range Level Sensor PXS-069 Attachment B

  • Excerpt from COL Appendix C Table 2.2.3-1 Table 2.2.3-1
  • Remotely Operated
  • Equipment Name
  • Tag No.

Valve CMT A Discharge Isolation Valve PXS-PL-V014A YES CMT B Discharqe Isolation Valve PXS-PL-V014B YES CMT A Discharqe Isolation Valve PXS-PL-V015A YES CMT B Discharge Isolation Valve PXS-PL-V015B YES Nitroqen Supply Containment Isolation Valve PXS-PL-V042 YES PRHR HX Control Valve PXS-PL-V1 OBA YES PRHR HX Control Valve PXS-PL-V1 OBB YES IRWST Gutter Isolation Valve PXS-PL-V130A YES IRWST Gutter Isolation Valve PXS-PL-V130B YES Attachment C

  • Excerpt from COL Appendix C Table 2.2.3-1 Table 2.2.3-1
  • Equipment Name
  • Tag No.
  • Control PMS CMT A Discharge Isolation Valve PXS-PL-V014A YES CMT B Discharqe Isolation Valve PXS-PL-V014B YES CMT A Dischaq::ie Isolation Valve PXS-PL-V015A YES CMT B Discharqe Isolation Valve PXS-PL-V015B YES Nitroqen Supply Containment Isolation Valve PXS-PL-V042 YES PRHR HX Control Valve PXS-PL-V1 OBA YES PRHR HX Control Valve PXS-PL-V108B YES IRWST Gutter Isolation Valve PXS-PL-V130A YES IRWST Gutter Isolation Valve PXS-PL-V130B YES
  • Safety-Related Display Yes Yes Yes Yes Yes Yes Yes Yes
  • Active Function Transfer Open Transfer Open Transfer Open Transfer Open Transfer Closed Transfer Open Transfer Open Transfer Closed Transfer Closed
  • Active Function Transfer Open Transfer Open Transfer Open Transfer Open Transfer Closed Transfer Open Transfer Open Transfer Closed Transfer Closed

U.S. Nuclear Regulatory Commission N 0-21-1129 Enclosure Page 8 of 9 Attachment D

  • Excerpt from COL Appendix C Table 2.2.3-1 Table 2.2.3-1
  • Remotely Unit
  • Equipment Name
  • Tag No.

Operated Valve 3

CMT A Discharqe Isolation Valve PXS-PL-V014A Yes 3

CMT B Discharqe Isolation Valve PXS-PL-V014B Yes 3

CMT A Discharge Isolation Valve PXS-PL-V015A Yes 3

CMT B Discharqe Isolation Valve PXS-PL-V015B Yes 3

PRHR HX Control Valve PXS-PL-V1 OBA Yes 3

PRHR HX Control Valve PXS-PL-V108B Yes Attachment E

  • Excerpt from COL Appendix C Table 2.2.3-1 Table 2.2.3-1
  • Control Opening PMS Time Yes 14 sec Yes 14 sec Yes 15 sec Yes 15 sec Yes 12 sec Yes 12 sec
  • Remotely
  • Loss of Operated Motive Power
  • Equipment Name
  • TaQ No.

Valve Position CMT A Inlet Isolation Motor-operated Valve PXS-PL-V002A Yes As Is CMT B Inlet Isolation Motor-operated Valve PXS-PL-V002B Yes As Is CMT A Discharqe Isolation Valve PXS-PL-V014A Yes Open CMT B Discharge Isolation Valve PXS-PL-V01 4B Yes Open CMT A Discharge Isolation Valve PXS-PL-V015A Yes Open CMT B Discharqe Isolation Valve PXS-PL-V015B Yes Open Accumulator A Discharge Isolation Valve PXS-PL-V027A Yes As Is Accumulator B Discharge Isolation Valve PXS-PL-V027B Yes As Is Nitroqen Supply Containment Isolation Valve PXS-PL-V042 Yes Closed PRHR HX Inlet Isolation Motor-operated Valve PXS-PL-V101 Yes As Is PRHR HX Control Valve PXS-PL-V1 OBA Yes Open PRHR HX Control Valve PXS-PL-V108B Yes Open Containment Recirculation A Isolation PXS-PL-V117A Yes As Is Motor-operated Valve Containment Recirculation B Isolation PXS-PL-V117B Yes As Is Motor-operated Valve Containment Recirculation A Squib Valve PXS-PL-V118A Yes As Is Containment Recirculation B Squib Valve PXS-PL-V118B Yes As Is Containment Recirculation A Squib Valve PXS-PL-V120A Yes As Is Containment Recirculation B Squib Valve PXS-PL-V120B Yes As Is IRWST Injection A Squib Valve PXS-PL-V123A Yes As Is IRWST Injection A Squib Valve PXS-PL-V123B Yes As Is IRWST Injection A Squib Valve PXS-PL-V125A Yes As Is IRWST Injection A Squib Valve PXS-PL-V125B Yes As Is IRWST Gutter Isolation Valve PXS-PL-V130A Yes Closed IRWST Gutter Isolation Valve PXS-PL-V130B Yes Closed

U.S. Nuclear Regulatory Commission ND-21-1129 Enclosure Page 9 of 9 Attachment F

  • Excerpt from COL Appendix C Table 2.2.3-3 Table 2.2.3-3
  • Equipment
  • Tag No.

CMT A Discharqe Isolation Valve (Position)

PXS-PL-V014A CMT B Discharge Isolation Valve (Position)

PXS-PL-V014B CMT A Discharge Isolation Valve (Position)

PXS-PL-V015A CMT B Discharqe Isolation Valve (Position)

PXS-PL-V015B Accumulator A Nitroqen Vent Valve (Position)

PXS-PL-V021A Accumulator B Nitroqen Vent Valve (Position)

PXS-PL-V021 B Accumulator A Discharge Isolation Valve (Position)

PXS-PL-V027A Accumulator B Discharge Isolation Valve (Position)

PXS-PL-V027B PRHR HX Control Valve (Position)

PXS-PL-V1 OBA PRHR HX Control Valve (Position)

PXS-PL-V1 0SB Containment Recirculation A Isolation PXS-PL-V117A Motor-operated Valve (Position)

Containment Recirculation B Isolation PXS-PL-V117B Motor-operated Valve (Position)

Containment Recirculation A Squib Valve (Position)

PXS-PL-V118A Containment Recirculation B Squib Valve (Position)

PXS-PL-V118B Containment Recirculation A Squib Valve (Position)

PXS-PL-V120A Containment Recirculation B Squib Valve (Position)

PXS-PL-V120B IRWST Line A Isolation Valve (Position)

PXS-PL-V121A IRWST Line B Isolation Valve (Position)

PXS-PL-V121 B IRWST Injection A Squib Valve (Position)

PXS-PL-V123A IRWST Injection A Squib Valve (Position)

PXS-PL-V123B IRWST Injection A Squib Valve (Position)

PXS-PL-V125A IRWST Injection A Squib Valve (Position)

PXS-PL-V125B IRWST Gutter Isolation Valve (Position)

PXS-PL-V130A IRWST Gutter Isolation Valve (Position)

PXS-PL-V130B Accumulator A Level Sensor PXS-JE-L021 Accumulator B Level Sensor PXS-JE-L022 Accumulator A Level Sensor PXS-JE-L023 Accumulator B Level Sensor PXS-JE-L024 PRHR HX Inlet Temperature Sensor PXS-JE-L064 IRWST Surface Temperature Sensor PXS-JE-L041 IRWST Surface Temperature Sensor PXS-JE-L042 IRWST Bottom Temperature Sensor PXS-JE-L043 IRWST Bottom Temperature Sensor PXS-JE-L044

  • Display Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes (Position)

Yes Yes Yes Yes Yes Yes Yes Yes Yes