ML23129A174

From kanterella
Jump to navigation Jump to search

Accident Tolerant Fuel (ATF) Lead Test Assemblies (Ltas) License Amendment Request (LAR) and Exemptions
ML23129A174
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 04/28/2023
From: John Lamb
Plant Licensing Branch II
To: Joyce R
Southern Nuclear Operating Co
References
EPID L-2022-LLA-0097
Download: ML23129A174 (1)


Text

(12-2020)

NRC FORM 699 U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD Page 1 of 1 NRC Form 699 (12-2020)

NAME OF PERSON(S)/TITLE CONTACTED OR IN CONTACT WITH YOU Ryan Joyce, SNC Licensing Manager DATE OF CONTACT 04/28/2023 E-MAIL ADDRESS RMJoyce@southernco.com TELEPHONE NUMBER 2059926468 TYPE OF CONVERSATION E-MAIL TELEPHONE

INCOMING OUTGOING

ORGANIZATION Southern Nuclear Operating Company (SNC)

DOCKET NUMBER(S) 50-424 and 50-425 LICENSE NAME AND NUMBER(S)

Vogtle, Units 1 and 2 MAIL CONTROL NUMBER(S)

SUBJECT Vogtle, Units 1and 2, Accident Tolerant Fuel (ATF) Lead Test Assemblies (LTAs) License Amendment Request (LAR) and Exemptions

SUMMARY

AND ACTION REQUIRED (IF ANY)

On April 28, 2023, the NRC staff held a call with SNC to explain that the control rod ejection accident analysis in Vogtle, Units 1 and 2, ATF LTAs LAR, dated June 30, 2022, stated that the LTAs needed to be installed in non-limiting locations, and this contradicted the proposed Technical Specification (TS) change that stated the LTAs can be installed in limiting locations without any caveats. In addition, SNC requested that exemptions to Title 10 of the Code of Federal Regulations (10 CFR), Section 50.46, and 10 CFR part 50, Appendix K for Vogtle, Units 1 and 2; however, the ATF LTAs are proposed to be installed in Vogtle, Unit 2, only.

SNC representatives stated that they understood the NRC concerns and would supplement the Vogtle ATF LTAs request with a revised TS markup and clarify the exemption applicability.

NAME OF PERSON DOCUMENTING CONVERSATION John G. Lamb Add 1 Continuation Page Delete 1 Continuation Page SIGNATURE AND DATE John G. Lamb Digitally signed by John G. Lamb Date: 2023.05.08 15:00:41 -04'00'