Requests Analysis & Proposed Tech Specs Re Significant Change in Shape of Scram Reactivity Curve Which Could Occur W/Core Burnup,Variations in Fuel Enrichment & Configuration of Gadolinium Oxide in Core within 30 Days
ML20235E704
Person / Time
Site: Dresden, Quad Cities, 05000000
Issue date: 11/14/1972
From: Skovholt D
US ATOMIC ENERGY COMMISSION (AEC)
To: Butterfield L
COMMONWEALTH EDISON CO.
Shared Package
ML20235B311 List: ... further results
References
FOIA-87-111 NUDOCS 8709280235
Download: ML20235E704 (1)


Text

- - _. _

.}

.(

9 Distribution 4 cket Files pg y 4 g PDRs' Local PDRS i

RP Reading DocM m. 50-237, 50-249, Branch Reading' 3

50-265 ACRS (16)

-I

~

DJSkovholt, L:OR TJCarter, L:0R' l

R0 (3)

MKarman, OGC

-Conanonwealth Edison Company DLZiemann, L:cRB #2 ATTN.

L*r. L. D. Butterfield, Jr.

RDSilver, L:CRB #2 Nuclear Licensing Mainistrator JIRiesland, L:0RB #2 Post Offica Box 767 RMDiggs, L:0RB'#2 1

1 Cnicago, Illinois 60690 Gentlemen:

Analyses performed for other BWas have shown that a significant change in the shape of the scram reactivity cune could occur with core.

[

burnup,_ variations in fuel e.:riciment, and configuration of gadolinium oxide.in the core. This, change can resnlt in a change in the transient

~

-l analy'ses 'describod in the FSAR and a change to the Technical Specifi cations on control rod drivo scra:n ti=es and rod reactivity worth limitations for the Dresden 2 and 3 Unita and the Quad-Citics Station.

It is our understanding that you are aware of this situation aud are preparing an analysis with approirriate re,:camoudations.

It is requested that the analysis and any proposed technical specification p

j be submitted within 30 days with three sig:..ed originals and thirty seven additional' copica. If your submittal is in the form of a single document involving all four unito, please submit a total of sixty copios in lieu of forty.

Sincerely,

c.+pa wp.a bx

[p. J. shnh&:

Donald J. Skcvholt Assistant Director for 8709280235 870921 Operating Reactors PDR FOIA PDR Directorate of Liconr:ing MENZ87-111 cc:

Hr. Charles Whitmore Joan W. Ro.ic, Esquiro President and Chairman Isham, Lincoln & Beale Iowa-Illinois Gas and Counselors at Law Electric Compa67 Q)}T omer, L:0RB 2 L: ORB #2 L:vRB_#2 L:QRB_$2 ), L:CR g