.n . . .

.. A -

~ April 6, 1987 '

Docket Nos. 50-353

~

LICENSEE: ' Philadelphia Electric Company FACILITIY: Limerick' Generating Station, Unit.2- -

SUBJECT:

SUMMARY

5FJANUARY 15, 1987 MEETING ON USE 0F.ASME CODE CASE N-411

On' January 15, 1987, representatives of the Philadelphia Electric Company met with the NRC staff in Bethesda, Maryland. The subject of the meeting was the use of ASME Code Case N-411. " Alternative Damping Values for Seismic Analysis of Classes 1, 2 End 3 Piping Sections,Section III, Division 1" in the ongoing construction of Unit 2. A list of. attendees is provided in the Enclosure.

Earlier meetings.had been held on this subject on October 8, November 7 and December 3, 1986. In those meetings,;the applicant presented its various-analytical approaches, including the results of reanalyses, to juttify the use

-of the ISM method with N-411 damping for Limerick Unit 2 Piping. Details of the reanalyses were submitted to the staff by letters dated December 24, 1986 and January 13, 1987. This meeting was held to discuss the infonnation in those two letters.. The extensive information presented by the applicant for review during;this meeting is provided as Attachment 3 to the applicant's

-letter of January 26, 1987.~

As a result of this meeting, the licensee submitted a subsequent letter' dated January 26, 1987 which responded to issues discussed during the meeting. The staff's safety evaluation reporting the resolution of this matter was issued by

. letter dated March 27, 1987. -

OW signed by -

Robert E. Martin, Project Manager BWR Project Directorate No. 4 Division of BWR Licensing l.

Enclosure:

As stated cc: See next page 6 EJordan

-NRC PDR- BGrimes

LPDR ACRS(10)

PDf4 Reading M0'Brien .

WButler . R. Li RMartin/RCaruso R. LaGrange, Rg. 1 Vogler, OGC NRC Participants s7040so304 s70406 PDR ADOCK 05000353 A PDR ,

ca ut r f/o//87 __a_.__.

A/h/87 _. _ .. . _ _ _ , _ _ _ _

e 4 p2 KEI

  1. ~4 UNITED sTA.TEs N NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 V $ ,$

April 6, 1987 Docket Nos. 50-353 LICENSEE: Philadelphia Electric Company FACILITIY: Limerick Generating Station, Unit 2

SUBJECT:

SUMMARY

OF JANUARY 15, 1987 MEETING ON USE OF ASME CODE CASE N-411 On January 15, 1987, representatives of the Philadelphia Electric Company met with the NRC staff in Bethesda, Maryland. The subject of the meeting was the use of ASME Code Case N-411, " Alternative Damping Values for Seismic Analysis of Classes 1, 2 and 3 Piping Sections,Section III, Division 1" in the ongoing construction of Unit 2. A list of attendees is provided in the Enclosure.

Earlier meetings had been held on this subject on October 8, November 7 and December 3, 1986. In those meetings, the applicant presented its various '

analytical approaches, including the results of reanalyses, to justify the use of the ISM method with N-411 damping for Limerick Unit 2 Piping. Details of the reanalyses were submitted to the staff by letters dated December 24, 1986 and January 13, 1987. This meeting was held to discuss the information in those two letters. The' extensive information presented by the applicant for review during this meeting is provided as Attachrent 3 to the applicant's letter of January 26, 1987.

As a result of this meeting, the licensee submitted a subsequent letter dated January 26, 1987 which responded to issues discussed during the meeting. The staff's safety evaluation reporting the resolution of this matter was issued by letter dated March 27, 1987.

Q u?&

Robert E. Martin, Project Manager BWR Project Directorate No. 4 Division of BWR Licensing i

Enclosure:

As stated cc: See next page

. \

i

- Mr. Edward G. Bauer, Jr Limerick Generating Station

- Philadelphia Electric Company Units 1 8 2 cc:

Troy B. Conner, Jr., Esquire Chaiman Board of Supervisors of Conner.and Wetterhahn Limerick Township 1747 Pennsylvania Ave, N.W. 646 West Ridge Pike Washington, D. C. 20006 Limerick, Pennsylvania 19468 Barry M. Hartman- Frank R. Romano, Chairman Office of General Counsel Air & Water Pollution Patrol Post Office Box 11775 61' Forest Avenue Harrisburg, Pennsylvania 17108 Ambler, Pennsylvania 19002 Federic M. Wentz Dept. of Environmental Resources County Solicitor ATTN: Director, Office Radiologic County of Montgomery Health Courthouse P. O. Box 2063 Norristown, Pennsylvania 19404 Harrisburg, Pennsylvania 17105 Mr. John Franz, Plant Manager Mr. David Stone Limerick Generating Station Limerick Ecology Action, Inc.

Post Office Box A P. O. Box 761 Sanatoga, Pennsylvania 19464 Pottstown, Pennsylvania 19464 Mr. Karl Abraham - Thomas Gerusky, Director Public Affairs Officer Bureau of Radiation Protection Regior; I PA Dept. of Environmental Resources U.S. Nuclear Regulatory Commission P. O. Box 2063 631 Park Avenue Harrisburg, Pennsylvania 17120 King of Prussia, PA 19406 Mr. Gene Kelly Governor's Office of State Senior Resident Inspector Planning and Development U.S. Nuclear Regulatory Commission ATTN: Coordinator, Pennsylvania P. O. Box 47 State Clearinghouse Sanatoga, Pennsylvania 19464 P. O. Box 1323 Harrisburg, Pennsylvania 17102 i

.... l

, Philadelphia Electric Company Limerick Generating Station 1/2 cc:

' Director Pennsylvania Emergency Management Agency Basement, Transportation &

Safety Building Harrisburg, Pennsylvania 17120 Robert L. Anthony. Angus Love, Esq.

Friends of the Earth 107 East Main Street of the Delaware Valley Norristown, Pennsylvania 19402 103 Vernon Lane, Box 186 Moylan, Pennsylvania 19065 Helen F. Hoyt, Chairman Charles E. Rainey, Jr., Esquire Administrative Judge Chief Assistant City Solicitor Atomic Safety & Licensing Board Law Department, City of Philadelphia U.S. Nuclear Regulatory Comission One Reading Center Washington, D. C. 20555 1101 Market Street, 5th Floor Philadelphia, PA 19107 David Wersan, Esq. Dr. Jerry Harbour Assistant Consumer Advocate Administrative Judge Office of Consumer Advocate Atomic Safety & Licensing Board 1425 Strawberry Square U.S. Nuclear Regulatory Comission Harrisburg, Pennsylvania 17120 Washington, D. C. 20555 Dr. Richard F. Cole Mr. Spence W. Perry, Esq.

Administrative Judge Associate General Counsel .

Atomic Safety & Licensing Board Federal Emergency Management Agency U.S. Nuclear Regulatory Comission Room 840 Washington, D. C. 20555 500 C St., S.W.

Washington, D. C. 20472 Mr. J. T. Robb, NS-1 Fhiladelphia Electric Company l 2301 Market Street l

Philadelphia, Pennylsvania 19101 Timothy R. S. Campbell, Director Department of Emergency Services 14 East Biddle Street

( West Chester, Pennsylvania 19380 l

l

, (" '

e Enclosure 1 ATTENDEES January 15, 1987 Meeting on USE OF ASME Code Case N-411 Name Affiliation R. E. Martin NRC/ DBL Y. Li NRC/ DBL /EB R. LaGrange NRC/ DBL /EB K. A. Hudson PEco/PPDS/D&M C. S. Haynes Betchel-Pottstown M. H. Lee Bechtel - S. F.

T. E. Bostrom Bechtel - S. F.

L. Memula Bechtel - S. F.

R. R. Hess PECo - Mech. Eng. Div.

J. T. Robb PECo - Mech. Eng. Div.

D. R. Helwig PECo - Mech. Eng. Div.

t Mark Wisenburg HL&P - South Texas i R. Pence GE J. Thompson GE

- - . . . . . . . - - - , , , . , . - , . _ _ . ,