05000282/LER-1998-011, Forwards LER 98-011-00 Re Improper Acceptance Criteria in Surveillance Procedure.Util Has Made One New NRC Commitment as Indicated in Corrective Action Section Statement in Bold Italics

From kanterella
(Redirected from ML20151Y311)
Jump to navigation Jump to search
Forwards LER 98-011-00 Re Improper Acceptance Criteria in Surveillance Procedure.Util Has Made One New NRC Commitment as Indicated in Corrective Action Section Statement in Bold Italics
ML20151Y311
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 09/14/1998
From: Sorensen J
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20151Y313 List:
References
NUDOCS 9809180192
Download: ML20151Y311 (1)


LER-2098-011, Forwards LER 98-011-00 Re Improper Acceptance Criteria in Surveillance Procedure.Util Has Made One New NRC Commitment as Indicated in Corrective Action Section Statement in Bold Italics
Event date:
Report date:
2822098011R00 - NRC Website

text

. . .

Northern States Power Company Prairie Island Nuclear Generating Plant l 1717 Wakonade Dr. East Welch, Minnesota 55089 September 14,1998 Section 50.73 U S Nuclear Regulatory Commission Attn: Document Control Desk  !

Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50-282 License No. DPR-42 l

LER 1-98-11 Improper Acceptance Criteria in Surveillance Procedure i

The Licensee Event Report for this occurrence is attached, in the report, we have I made one new NRC commitment as indicated in the Corrective Action section statement in bold italics.

Please contact us if you require additional information related to this event.

Joel P. Sorensen Plant Manager Prairie Island Nuclear Generating Plant c: Regional Administrator- Region ill, NRC

NRR Project Manager, NRC {

Senior Resident inspector, NRC y' l

l Kris Sanda, State of Minnesota

[h<r")

'/

l Attachment 9809180192 980914

,yv (DR ADOCK 05000282 PDR l